Report (38) • Job Name: System Reference: 1 Q Date: Indoor Unit: Outdoor Unit: PKA-A36KA7 D PUY-A36NKA7 Ci i i� OF ❑ PUY-A36NKA7-BS BUILDING DIVI. I3 i-0111F0 , II 'II10I11IIIIINIIIIIIIIII ( 0r I' fif11111111111111111 fFt I, ��IIIIIIIIIII� IIIIIIII 4.7..' �l1! . .I ilM V• III IIS'' ,5 %; mor _ ' /"` 1;1:71011 I II IIIIII�IIlhI�IbI ' I1I1IIIIIIII II IIIIIIIf I INI ' ' IIIIIIIIIIIIIIIIIIIIIIII ILII ,i f_ y � IIIl IIiIIlhIII giamu INDOOR UNIT FEATURES • Sleek,compact design • Simple installation • Vane setting for air flow direction control • Auto fan speed mode • Ideal for spaces such as server rooms,daycare centers,classrooms,churches,small offices,and more OUTDOOR UNIT FEATURES • Variable speed INVERTER-driven compressor • Suction accumulator pre-charged with refrigerant volume for piping length up to 100 ft(70 ft.for Al2/18/24/30) • Low ambient cooling down to-20°F providing 100%capacity(only for PUY models with wind baffles installed) • 24-hour continuous operation(cooling mode) • High pressure protection • Fast restart due to bypass valve make it ideal for equipment cooling applications,such as data centers • Superior energy and operational efficiency Specifications are subject to change without notice. cO 2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. tt �4f A6NKA7-35 Maximum Capacity Btu/h 36,000 Rated Capacity Btu/h 36,000 Minimum Capacity Btu/h 16,000 --Maximum Power Input W 3,330 Coolingl Rated Power Input W 3,330 Moisture Removal Pints/h 9.7 Sensible Heat Factor 0.70 Power Factor % 96.5 SEER 18.8 Efficiency ---......._._..._._._- —.._---- EER1 10.8 Voltage, Phase,Frequency 208/230V, 1-phase,60 Hz Guaranteed Voltage Range V AC 198–253 Voltage:Indoor-Outdoor,S1-S2 VAC 208/230 Electrical Voltage:Indoor-Outdoor,S2-S3 V DC 24 Voltage: Indoor-Remote controller V DC 12 Recommended Fuse/Breaker Size A • 30 Recommended Wire Size(Indoor-Outdoor) AWG 14 MCA A 1 •Fan Motor Full Load Amperage A • 0.57 Fan Motor Output W 56 Airflow Rate, Dry CFM 705-810-920 Airflow Rate,Wet CFM 635-730-830 External Static Pressure in.WG n/a Sound Pressure Level dB(A) 43-46-49 Drain Pipe Size In.(mm) 5/8(16) Condensate Lift Mechanis la.(mm) Indoor Unit Heat Exchanger Type Plate fin coil External Finish Color i White Munsell 1.0Y 9.2/0.2 W:In.(mm) 46-1/16(1170) Unit Dimensions D:In.(mm) 11-5/8(295) H:In.(mm) 14-3/8(365) W:In. 51 Package Dimensions D:In. 18-8/16 H: In. 14-4/16 Unit Weight Lbs.(kg) 46(21) Package Weight Lbs. 53 Indoor Unit Operating Cooling Intake Air Temp(Maximum/Minimum) °F 90 DB,73 WB/66 DB,59 WB Temperature range Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. MCA A 25 MOCP A 31 Fan Motor Full Load Amperage A 0.5+0.5 Fan Motor Output W 74+74 Airflow Rate CFM 3,880 Refrigerant Control Electronic Expansion Valve Heat Exchanger Type Cross fin Sound Pressure Level,Cooling dB(A) 52 Compressor TypeINVERTER driven twin rory s Compressor Model MNB33FBRMC-L ta Compressor Rated Load AmpA 8 Outdoor Unit or Oil Type//Charge Compressor Locked Rotor Amps A 13 Compressoz. FV50S//45 External Finish Color Ivory Munsell 3Y 7.8/1.1 Base Pan Heater n/a W:In.(mm) 1050[41-5/16] Unit Dimensions D:In.(mm) 13+521:411312::::116.6_51;(31113663038+ 1-3/16(330+30) H: In.(mm) 52-11/16(1338) W:In. 42-15/16 Package Dimensions D:In. 17-11/16 - H: In. _---.-____ 56-4/16 Unit Weight Lbs.(kg) 211 (96) Package Weight Lbs.(kg) 243(110) Outdoor Unit Operating Cooling Intake Air Temp(Maximum/Minimum) °F 115 DB/-20�DB Temperature Range Type R410A Refrigerant — —._......................----..__......_..._._......_.................._................._. i Charge Lbs,az 10 lbs,6 oz Gas Pipe Size O.D.(Flared) In.(mm) 5/8(15.88) Liquid Pipe Size O.D.(Flared) In.(mm) 3/8(9.52) Piping Maximum Piping Length Ft.(m) 225(69) Maximum Height Difference Ft.(m) 100(30) Maximum Number of Bends 15 Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. ft-iiti YA � Notes AHRI Rated Conditions(Rated data is 1Cooling(Indoor//Outdoor) °F 80 DB,67 WB//95 DB,75 WB determined at a fixed compressor speed) *Wind baffles required to operate below 23°F DB in cooling mode.PUY with wind baffle:-20°F-115°F.Refer to wind baffle documentation for further information. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. SEACOAST PROTECTION • External Outer Panel:Phosphate coating+Acrylic-Enamel coating • Fan Motor Support:Epoxy resin coating(at edge face) • Separator Assembly;Valve Bed:Epoxy resin coating(at edge face) • `Blue Fin"treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. Signal Receiver ❑PAR-SA9CA-E Wireless Remote Controller o PAR-FL32MA-E Wireless Remote Receiver ❑PAR-FA32MA E Backlit,Wall-mounted,Wireless Controller ❑MHK1 Portable Central Controller o MCCH1 Wired MA Controller o PAR-33MAA Simple MA Controller 0PAC-YT53CRAU Touch MA Controller o PAR-CTO1MAU-SB Wired Remote Sensor 0PAC-SE4ITS-E Lockdown Bracket for Wireless,Hand-held,Remote Controller o RCMKP1CB Wireless Temperature and Humidity Sensor ❑PAC-USWHS003-TH-1 Outside Air Sensor for MHK1 ❑MOS1 Flush Mount Remote Temperature Sensor ❑PAC-USSEN001-FM-1 Wireless Interface o PAC-USWHS002-WF-1 Thermostat Interface ❑PAC-US444CN-1 kumo station® o PAC-WHS01 HC-E USNAP Interface ❑PAC-WHS01 UP-E IT Extender o PAC-WHS01 IE-E BACnet®and Modbus Interface 0PAC-UKPRC001-CN-1 Connector for CN32(remote on/off) o PAC-SE55RA-E External Drain Pump o PAC-KEO7DM-E External Drain Pump o PAC-SH94DM-E Blue Diamond Sensor Extension Cable-15 Ft. o C13-103 Mini Condensate Pump-230V application o S130-230 MegaBlue Advanced Blue Diamond Condensate Pump w/Reservoir&Sensor o X87-835 110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(208/230V)up to 48,000 Btu/h ❑X87-721 -208/230V [recommended] Drain Pan Level Sensor(Control for indoor unit shut off to prevent drain pan overflow) ❑DPLS2 3 Pole Disconnect Switch(30A/600VUL)[fits 2"X4"utility]-Black ❑TAZ-MS303 3 Pole Disconnect Switch(30A/600VUL)[fits 2"X4"utility]-White o TAZ-MS303W Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. UUPR Twinning Distribution Pipe(50:50) o MSDD-50TR-E Air Outlet Guide o PAC-SH96SG-E(two pieces are required) Front Wind Baffle o WB-PA3(two pieces are required) Drain Socket o PAC-SG61 DS-E M-NET Converter ❑PAC-SF83MA-E M-NET Converter ❑PAC-SJ95MA-E Control/Service Tool ❑PAC-SK52ST Condensing Unit Mounting Pad 24"x 42"x 3" ❑ULTRILITE2 Outdoor Unit Stand-12"High ❑QSMS1202M Outdoor Unit Stand-18"High o QSMS1802M Outdoor Unit Stand-24"High o QSMS2402M Heavy Duty Wall Mounting Bracket for Outdoor Units—Coated Steel o QSWB2000M-1 Heavy Duty Wall Mounting Bracket for Outdoor Units-316 Series Stainless Steel o QSWBSS 3/8"x 5/8"x 10'/1/2"Lineset(Twin-Tube Insulation) o MPLS385812T-10 3/8"x 5/8"x 15'/1/2"Lineset(Twin-Tube Insulation) ❑MPLS385812T-15 3/8"x 5/8"x 30'/1/2"Lineset(Twin-Tube Insulation) ❑MPLS385812T-30 3/8"x 5/8"x 50'/1/2"Lineset(Twin-Tube Insulation) ❑MPLS385812T 50 3/8"x 5/8"x 65'/1/2"Lineset(Twin-Tube Insulation) ❑MPLS385812T-65 3/8"x 5/8"x 100'/1/2"Lineset(Twin-Tube Insulation) ❑MPLS385812T-100 Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. iis :,.. , , :4Vii4a*AltMANATierilielitb,'40tMek,St 7 & PU PKA-A36KA7 Unit: inch (mm) Too side o 16-11H6(423.7) _ 17(431.7) 7. r� i / 1 11 • ' `1 I I • z--02.ILI --„.1 -„, i 1 Left side rranl side 1,1,11 aNe —- ` ---I" h ill.7P ---- Mourn boan1 o-n pMk 11 1 br kh prq Lr e 29132(74) + IIN 3321/32(845) 4112(241) \ 6,01 Cs] 3116(51 A 4bi176(1176) Fron,ske(CMe open) c9.mon bm2 1(2148/6* --� for r9hl PVn9 -- - 0111111 --- [fir D6FaosrrsTAMD BY bmp ��6 N1I 1IU l� r retinal nook tar omaoor una iiiij iiiill! .l TermineIMockror..wer : ion 'l� �1� -�i li_--� _ !+ Tetrnirral bock br 2 /' MA-rarto a c2Mroller ry IEE-Er ! Filter_ _- r ■I 1-3 Den hose M 542)444)Gas p pe pt rI 4-27!32(123) Y 2-1932•• 18-31r32(482)leuid wce 1116151) 58132(134) �� Under We Ilan Piping connection r . I9 idPI Refrigerant pipe: O.D09.52) 6verea '''''''''n 74\B �LupeFlared connection:3/8F Knockout sleeve f°r'a"�rp'°"° Refrigerant pipe:5/8 0.D(015.88) (purchased locally) Through hole 02 Gas pipe Flared connection:5/8F $2-15/16 ¢2-15/16-03-5/32 )Drain hose 5/8016)O.D 4675-993°) Effective length:23-1/32(585) Required spece(Indoor und) Air inlet 1�%� Knockout hole for piping r.. ..MMIM.1:1 11111. 't ,,- .k Air outlet •1. `UI_I .����. I� m,,,.8.21,32. ��..„.1. 100.5 n -241/166 li'3132 i$4)11.65 Min.2-1M•523 3-m6(8d' 13/32 10. 2 Center measurement hole 92 o L¢11nz(1kor Ire nae .j all_ _ o .e uomtboa 3 e skF: R 'c e a# a T 'I -.k4 = r peg • -a $ aoe erMow.e ��r�rrII�ra==�i.��ar�•..- x;/31 ''173,::' ects it r �1 �.r 1 3,�91{5s) ,--r–. ... . �� •— 1 1-682926/) 1 _ 6 1��e� c �e��n�4 hill aiv,est��1a_ a.�l 9� _ _ 3n6ecros) S»93(1 N� 772,1_1 6391(133.51 _�6/193111 ,+arcs invent$:. - !!=. e1:�10_, o., j 66.633"iriiiiiiiiii�k 1fli \;>6 ) S R a ,& - o m i e:1 e 8 e ! zc S SY. r `a= - 2 _ 8 .5 — hole. _ Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. n1MENSi � y PUY-A36NKA7(-BS) Unit: mm<in> 1 FREE SPACE(Around the unit) 2 SERVICE SPACE 3 FOUNDATION BOLTS 4 PIPING-AIRING DIRECTIONS RearA r In eke n The diagram below shows a basie example. Dimenaiona or apace needed Please aerare me ars P1mb aging and wiring conneolpna v a rel Lepinbon of pedicular details are for cordon access are wish 4 fourdafion(MI O4 318>)bolls. can be made from 4 drecbona: ` given in the installation rnanuale etc. shown in the below diagram. (Bobs and washers must be FROM,Right Rear and Below. F� erchesedlaaly.) v���v�������v Side Air Intake A � <Foundation boM hegM> �.- / ,� Vi;J - /% A <19% c Air Discharge i_.,,,Lmn, <'-,..m S iiv�en�eauionn�mi 1050 X41-11132> Side Art Intake 062— tlwnneawn Rear Air Mike " �� (�'n�°�Ne wBimo Ilii y-. i 1 Egiv;pHoExam le of Notes Ip IIII llllu IIIb a l'91 III''li l .aahiyeram ons qac oon iaA> l a15881518Fl I,IIiii PI I'I III 2..RetrgeramuoulOv4e ec4on�FlARE1 ass2r�leF! �. lu IIII LII Senicepanel •..lndratiw W STOP VALE no mad. g 11,11 Han I1 V II IIIIIII,iI ..for i it lliilll,lilll �I�ilil�IIII ILII Randle for rnon. L11 III ' Id.i IIII�II'lll IIII Illl.li',i�I Ill llllllill�illlhl11 l IIII illll r!!111,1m11,14,,, • 111 le III Ill III��IIII! MCI - 0 6 1 z JP L Piping Knockout Hole Details ont shins raver / ra:roao<aam< ss<°nm y<avm, ,--,Z,„,, sti.aana wxae< ' ^ rcm r<unv Rea Gana<0>0 • anaiwre4awi owns, snmi Atle v° semwi wave ns<„a,� w■w .rnasl va ,, `I. ewwna _ � cwvd _— a*gi�ana. /onai�soroeawi �_ � / rx>&� "�� I lirE_ �����"� —• _ , 1"„e-,.,, NSI ppqq _ < n '"-- e _ _ _ yz<ysa. �_-__sealei5_--_2 IMr MaAl ,V r e— C K .. • MITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard,Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com Ara CERTIFIED.. cETA us FORM#PKA-A36KA7/PUY-A3ONKA7(-BS)-201810 na Intertek Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. rx 7 Job Name: System Reference: Date: ray 4% WB-PA3/WB-PA4/WB-PA5 GENERAL FEATURES MODEL REQUIRED PER OUTDOOR UNIT • WB-Series Wind Baffles allow P-Series outdoor units to operate at full capacity to 0°F DB cooling. UNIT MODEL a • Prevents wind from reversing outdoor fan rotation when un-energized. • Durable, low maintenance construction. PUY/Z-A24NHA4 1 • WB-PA3 Wind Baffle allows PUMY-P-NKMU1 outdoor units to operate down to 5°F DB at 100%capacity in cooling mode and down to-13°F DB PUY/Z-A3ONHA4 1 in heating mode with a de-rate. PUY/Z-A36NHA4 1 PLEASE NOTE PUY/Z-A42NHA4 2 • Install outdoor units with the back surface facing wall side to eliminate the PUY/Z-A42NHA5 2 effects of external wind. • Outdoor units should not be installed in an orientation or site where the PUZ-HA3ONHA4 2 wind blows directly at the back of the unit. • Wind baffle should not be used where there is any obstacle at either side PUZ-HA36NHA4 2 or above the outdoor unit as the discharged air will be blocked. PUZ-HA3ONHA5 2 SPECIFICATIONS PUZ-HA36NHA5 2 1 M PUZ-HA42NKA 2 Color Matches P-Series Outdoor Unit PUMY-P36NHMU 2 Surface PUMY-P36NKMU1 2 Exterior Treatment Polyester Powder Paint PUMY-P48NHMU 2 Material Alloy Hot-Dip Zinc Coated Carbon Steel Sheet PUMY-P48NKMU1 2 Weight 8 Lbs.8 Oz. 7 Lbs.7.9 Oz. 8 Lbs.8 Oz. PUMY-P6ONKMU/1 2 PUY/Z-A24NHA6 1 PUY/Z-A3ONHA6 1 PUY/Z-A36NHA6 1 PUY/Z-A42NHA6 2 PUY/Z-Al2NHA7 1 PUY/Z-A18NHA7 1 PUY/Z-A24NHA7 1 PUY/Z-A3ONHA7 1 PUY/Z-A36NHA7 2 PUY/Z-A42NKA7 2 Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC Requirements of space for installation (1)One unit installation: } -1 1-6 or more Wall surface 20 or more / A 7///////// L_ 6to16 6to16 II ( ) I ) 1 ( ) ( ) ji. 20 orf }more iii,-II 20 or more Wind Baffle /////////// 6 to 16--1 I— Wall surface \' /° (2)Multiple Unit Installation:Installation of multiple units in series must be no more than five units. 4‘11) / Wall surface j/////6 t/ 6///////////////////////// IL �:111-111 I O ( ) ( ) 6 to 16-1 -- L. 20 or more -20 or more L - 20 or more I 22.4 j--.5 I 23 1 -1—ItmEmr {f ALL DIMENSIONS IN INCHES ALL DIMENSION X32' 1 25 25.6 1 1 5 � 1 E a i=.zs i_CS aiiiiiiiiirs;i Specifications are subject to change without notice. 0 2018 Mitsubishi Electric Trane HVAC US LLC Requirements of space for installation (1)One unit installation: T -1 1---6 or more Wall surface 20 or more / 4 ////////// 2x2-01/4hole _i__ 6to16 6to16 E �I II i i 1 1 c } 20 or more 20 or more I- / Wind Baffle /////////// 22-3/8 6 to 16-1 1--- Wall surface (2)Multiple Unit Installation:Installation of multiple units In series must be no more than five units. / Wall surface /// 6t/ 6 // ////// / / )) . Back View 6 or more--I k- 20 or more – 20 or more 20 or more 1 77/8 ALL DIMENSIONS IN INCHES – 21-1/8 ALL DIMENSIONS±%32° Side View Top View Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC � iIJIW *J$ IwB4M1IIJIPIIIUIJjN Requirements of space for installation (1)One unit installation: 1 ---I 1-6 or more Wall surface 4 x X1114 20 or more / A '////////// L_ 6to16 6to16 1 1 1 ( > } c ) c > !i• D 20 or more II MI V -- 20 or more Wind Baffle /////////// 6 to 16-1 1— Wall surface (2)Multiple Unit Installation:Installation of multiple units in series must be no more than five units. il �/ Wall surface 9116 � st/f //f// // / 1 3/16 i � Back View 6 to 16— -- 20 or more - 20 or more – 20 or more – 23 – 7 718 — 71 314 6118 / \ I \ \ i ALL DIMENSIONS IN INCHES – 23-3/8 – + – 21 118 – ALL DIMENSION X32" Top Down View Side View Manufactured for MITSUBISHI ELECTRIC TRANE HVAC US LLC 1340 Satellite Boulevard.Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com FORM#WIND BAFFLE-201806 Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC itMA REMOTE CONTROLLER : tr,t'5s,„ a EOTTUC- Job Name: System Reference: Date: ci Ec sac 14 30 Fn14:30 '451.1 Room28:5`c® 3St.. 8 Set temp. Auto 1128.5 t x� f.. ... 1r If IIl (r�( (I ® Full View Basic View CAPABILITIES • Basic Operations • Outdoor Unit silent mode — On/Off — Schedulable:Mon,Tue,Wed,Thu,Fri,Sat,Sun — Operation Mode:Cool,Dry,Fan,Heat,Auto(Dual or Single set — Start/Stop times in 5-minute increments point) — Silent Levels:Normal,Middle,Quiet — Set Temperature • Energy saving features: — Fan Speed —Automatic return to preset temperature setpoint if set point is — Daylight Savings Time(DST) changed from the remote controller after a preset time range • Vane setting:Auto,Step 1-5,Swing Cool preset temp:Cool,Dry,Auto-Cool • Louver:Off,Swing On Heat preset temp:Heat,Auto-Heat • Vent.(Lossnay):Off,Low,High 0 Range of 30 to 120 minutes in 10-minute increments — Manual vane angle:No Setting,Step 1-5,Draft reduction,All outlet — Energy-saving Operation Schedule Draft reduction mode keeps the vane angle more horizontal than 0 Operation schedule the angle of Step 1 0 Four daily patterns with time periods in 5-minute increments and • Restriction energy-saving rate 0%to 90% — Set Temperature range limit 7 day programming — Operation lock:On/Off,Mode,Set Temp,Vane • Night setback • High power — Starts Heat/Cool operation when room temperature exceeds — Operate at higher-than-normal capacity to bring room to set preset temperature range temperature quickly for up to 30 minutes — Adjustable time range in 5-minute increments • No Occupancy Auto-OFF • Main display — 3D i-See sensor required — Full:Shows all icons and values • On/Off timer — Basic:Limited to Mode,Set Temp.,Fan,Time&Day — Set On Time in 5-minute increments • Backlight Display — Set Off Time in 5-minute increments • Adjustable Contrast Level — Repeat daily — Language:English,French,Spanish,Italian, Portuguese,Greek, — Home screen display icon Turkish,Swedish • Auto-Off timer • CITYMULTI®Function setting —Automatically turns unit off after preset time • Filter maintenance notification —Time range of 30 to 240 minutes in 10-minute increments • Error code notification — Home screen display icon • Weekly timer — Set each day Monday through Sunday — 1 to 4 time periods per day in 5-minute increments — Set Mode:On/Off/Auto(Dual set point) — On/Off/Auto — Set Temperature *(All Capabilities are dependent on the model connected) Specifications are subject to change without notice. Copyright©2017 Mitsubishi Electric US, Inc. SPECIFICATIONS DIMENSIONS Product size I In.(mm) 4 3/4 x 4 3/4 x 314 120[4-314] 19[3/4 (WxHxD) (120x120x19) Net weight I Lbs.(kg) 9/16(0.25) Rated power supply voltage 12 VDC (supplied from indoor units) Power W 0.3 v consumption Usage environment Temperature:0 to 40°C o (32to OOO O Humidity:30 t to 90%RH (with no condensation) Panel PMMAFront Material ( view) (Side view) Main body PC+ABS Sound Pressure I dB(A) <70[A-weighted sound Level pressure level]*1 *1 Per Machinery Directive 2006/42/EC Notes: • MITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard,Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com FORM#PAR-33MAA-J MA Remote Controller for CITYMULTI®- c1/ us 201706 Intertek Specifications are subject to change without notice. Copyright 0 2017 Mitsubishi Electric US, Inc.