Report (39)
mcc, \Q- 00\u. \O n , t7kI i co \N MITSUBISHI ' -SERIES SUBMITTALDATA A36KA7 &PKA7(-BSS 36,004 BTUJH WALL-MOUNTED H TEM ELECTRIC Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: G a PKA-A36KA7 ❑ PUZ-A36NKA7 'I' " o PUZ-A36NKA7-BS T OfIIIIIII�IIII IIII III SII II 11111111111111111111111111111110111, ,ig €� III�II1II�II", II 0� i3illinimillivr `� IIIA �i . . �: lie li# IN il111111 ., IohI - �IIIIIIIIIIl !I1 IIIIIEIIII INDOOR UNIT FEATURES • Sleek,compact design • Simple installation • Vane setting for air flow direction control • Auto fan speed mode • Ideal for spaces such as server rooms,daycare centers,classrooms,churches,small offices,and more OUTDOOR UNIT FEATURES • Variable speed INVERTER-driven compressor • Suction accumulator pre-charged with refrigerant volume for piping length up to 100 ft(70 ft.for Al2/18/24/30) • 24-hour continuous operation(cooling mode) • High pressure protection • Fast restart due to bypass valve make it ideal for equipment cooling applications,such as data centers • Superior energy and operational efficiency Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. a a ;, ONS: -A36KA & PUZ-A36NKA Nb)del Number ' ` 'f � � � � PUZ»A3 PtJZA36NKA7-F35 Maximum Capacity Btu/h 36,000 Rated Capacity Btu/h 36,000 Minimum Capacity Btu/h 16,000 Maximum Power Input W 3,330 Cooling1 Rated Power Input W 3,330 Moisture Removal Pints/h 9.70 Sensible Heat Factor 0.70 Power Factor % 96.50 Maximum Capacity Btu/h 40,000 Rated Capacity Btu/h 38,000 Minimum Capacity Btu/h 18,200 Heating at 47°F2 Maximum Power Input W 3,700 Rated Power Input W 2,460 Power Factor °k 95.50 Maximum Capacity Btu/h 25,900 Rated Capacity Btu/h 22,400 Heating at 17°F3 Maximum Power Input W 2,670 Rated Power Input W 2,610 SEER 18.80 EER*1 10.80 Efficiency HSPF(IV) 9.20 COP at 47°F2 4.52 COP at 17°F3 2.51 Voltage,Phase,Frequency 208/230V, 1-phase,60 Hz Guaranteed Voltage Range V AC 198—253 Voltage:Indoor-Outdoor,S1-S2 V AC 208/230 Electrical Voltage:Indoor-Outdoor,S2-S3 V DC 24 Voltage:Indoor-Remote controller V DC 12 Recommended Fuse/Breaker Size A 30 Recommended Wire Size(Indoor-Outdoor) AWG 14 MCA A 1.00 Fan Motor Full Load Amperage A 0.57 Fan Motor Output W 56 Airflow Rate,Dry CFM 705-810-920 Indoor Unit Airflow Rate,Wet CFM 635-730-830 Extemal Static Pressure in.WG n/a Sound Pressure Level dB(A) 43-46-49 Drain Pipe Size In.(mm) 5/8(16) Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. SPECIFICATIONS: PKA-A36KA7 & PUZ-A36NKA7(-BS) Indoor Unit PKA-A36KA7 Model Number PUZ-A36NKA7 Outdoor Unit P NKA7-BS Condensate Lift Mechanism,Max.Distance Ft.(m) n/a Heat Exchanger Type Plate fin coil External Finish Color White Munsell 1.0Y 9.2/0.2 W:In.(mm) 46-1/16(1170) Unit Dimensions D:In.(mm) 11-5/8(295) H:In.(mm) 14-3/8(365) W:In. 51 Package Dimensions D:In. 18-8/16 H:In. 14-4/16 Unit Weight Lbs.(kg) 46(21) Package Weight Lbs. 53 Indoor Unit Operating Cooling Intake Air Temp(Maximum/Minimum) °F 90 DB,73 WB/66 DB,59 WB Temperature Range Heating Intake Air Temp(Maximum/Minimum) °F 82 DB/50 DB MCA A 25 MOCP A 31 Fan Motor Full Load Amperage A 0.5+0.5 Fan Motor Output W 74+74 Airflow Rate CFM 3,880 Refrigerant Control Electronic Expansion Valve Defrost Method Reverse Cycle Heat Exchanger Type Cross fin Sound Pressure Level,Cooling1 dB(A) 52 Sound Pressure Level,Heating2 dB(A) 53 Compressor Type INVERTER-driven twin rotary Compressor Model MNB33FBRMC-L Outdoor Unit Compressor Rated Load Amps A 8 Compressor Locked Rotor Amps A 13 Compressor Oil Type//Charge oz. FV5OS//45 External Finish Color Ivory Munsell 3Y 7.8/1.1 Base Pan Heater n/a W:In.(mm) 1050[41-5/16] Unit Dimensions D:In.(mm) 330+30[13+1-3/16] ___ H:In.(mm) 1338[52-11/16] W:In. 42-15/16 Package Dimensions D:In. 17-11/16 H:In. 56-4/16 Unit Weight Lbs.(kg) 214(97) Package Weight Lbs.(kg) 245(111) Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. y ,",, moa � Indoor Unit � PKA-A36KA7a .� Outdoor �Q\ PUZ-A36NKA 6 Cooling Intake Air Temp(Maximum/Minimum) °F 115 DB/0*DB Outdoor Unit Operating Heating Intake Air Temp(Maximum/Minimum) °F 70 DB,59 WB 1-4 DB,-4 WB Temperature Range Thermal Lock-out/Re-start Temperatures** °F -8 1-4 DB Type R410A Refrigerant Charge Lbs,oz 10 lbs,6 oz Gas Pipe Size O.D.(Flared) In.(mm) 5/8(15.88) Liquid Pipe Size O.D.(Flared) In.(mm) 3/8(9.52) Piping Maximum Piping Length Ft.(m) 165(50) Maximum Height Difference Ft.(m) 100(30) Maximum Number of Bends 15 Notes AHRI Rated Conditions 1Cooling(Indoor//Outdoor) °F 80 DB,67 WB//95 DB,75 WB (Rated data is 2Heating at 47°F(Indoor//Outdoor) °F 70 DB,60 WB//47 DB,43 WB determined at a fixed compressor speed) 3Heating at 17°F(Indoor//Outdoor) °F 70 DB,60 WB//17 DB, 15 WB Conditions 4Heating at 5°F(Indoor//Outdoor) °F 70 DB,60 WB//-4 DB,-5 WB *Wind baffles required to operate below 23°F DB in cooling mode.PUZ with wind baffle:0°F-115°F. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. SEACOAST PROTECTION • Extemal Outer Panel:Phosphate coating+Acrylic-Enamel coating • Fan Motor Support:Epoxy resin coating(at edge face) • Separator Assembly;Valve Bed:Epoxy resin coating(at edge face) • "Blue Fin"treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airbome contaminants. Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. � L • qACCESSORIES: PKA.A36KA7 Signal Receiver ❑PAR-SA9CA-E Wireless Remote Controller o PAR-FL32MA-E Wireless Remote Receiver ❑PAR-FA32MA-E Backlit,Wall-mounted,Wireless Controller o MHK1 Portable Central Controller ;❑MCCH1 Wired MA Controller I o PAR-33MAA Simple MA Controller ❑PAC-YT53CRAU Touch MA Controller ❑PAR-CT01 MAU-SB Wired Remote Sensor ❑PAC-SE41TS-E Lockdown Bracket for Wireless,Hand-held,Remote Controller o RCMKP1CB Wireless Temperature and Humidity Sensor !o PAC-USWHS003-TH-1 Outside Air Sensor for MHK1 o MOS1 Flush Mount Remote Temperature Sensor I o PAC-USSEN001-FM-1 Wireless Interface o PAC-USWHS002-WF-1 Thermostat Interface ;❑PAC-US444CN-1 kumo station® ❑PAC-WHS01 HC-E USNAP Interface ❑PAC-WHS01 UP-E IT Extender 'o PAC-WHS01IE-E BACnet®and Modbus Interface o PAC-UKPRC001-CN-1 Connector for CN32(remote on/off) o PAC-SE55RA-E External Drain Pump o PAC-KE07DM-E External Drain Pump ;o PAC-SH94DM-E Blue Diamond Sensor Extension Cable-15 Ft. I❑C13-103 Mini Condensate Pump-230V application o 5130-230 MegaBlue Advanced Blue Diamond Condensate Pump w/Reservoir&Sensor E o X87-835-110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(208/230V)up to 48,000 Btu/h o X87-721 -208/230V [recommended] Drain Pan Level Sensor(Control for indoor unit shut off to prevent drain pan overflow) o DPLS2 3 Pole Disconnect Switch(30A/600VUL)[fits 2"X4"utility]-Black ;o TAZ-MS303 3 Pole Disconnect Switch(30A/600VUL)[fits 2"X4"utility]-White 1 o TAZ-MS303W Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. c Twinning Distribution Pipe(50:50) I o MSDD-50TR-E Air Outlet Guide i o PAC-SH96SG-E(two pieces are required) Front Wind Baffle o WB-PA3(two pieces are required) Drain Socket 'o PAC-SG61 DS-E M-NET Converter o PAC-SF83MA-E M-NET Converter o PAC-SJ95MA-E Control/Service Tool o PAC-SK52ST Condensing Unit Mounting Pad 24"x 42"x 3" o ULTRILITE2 Outdoor Unit Stand-12"High o QSMS1202M Outdoor Unit Stand-18"High ❑QSMS1802M Outdoor Unit Stand-24"High o QSMS2402M Heavy Duty Wall Mounting Bracket for Outdoor Units—Coated Steel o QSWB2000M-1 Heavy Duty Wall Mounting Bracket for Outdoor Units-316 Series Stainless Steel I o QSWBSS 3/8"x 5/8"x 10'/1/2"Lineset(Twin-Tube Insulation) o MPLS385812T-10 3/8"x 5/8"x 15'/1/2"Lineset(Twin-Tube Insulation) o MPLS385812T-15 3/8"x 5/8"x 30'/1/2"Lineset(Twin-Tube Insulation) ❑MPLS385812T-30 3/8"x 5/8"x 50'/1/2"Lineset(Twin-Tube Insulation) o MPLS385812T-50 3/8"x 5/8"x 65'/1/2"Lineset(Twin-Tube Insulation) o MPLS385812T-65 3/8"x 5/8"x 100'!1/2"Lineset(Twin-Tube Insulation) 1 o MPLS385812T-100 Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. A C I l PKA-A36KA7 Unit: inch(mm) if 1 1 1 - 7 1 1 1 ; , „ - - — _i . .__ i Lt. side s .°e ii1i ` ,A°un;Mare Kauetl -2 DI '{j r1! /9r52(/4) 33.21132(655 31,'!(211) 3116(3) A 1�11b(11/6) FrorR aiEe(3rAe°re") Operi6op lamp KnoclmN hole �- 1i1 OEFRO6T/STRN2 BYhr�p r"Gh'pFirq I,PI��11�11�11� T al bbcklo OUMpou n6 Iiiiisii iiiii■i I F:I Tenninalbbckrol.. ninon -E � ` ''I� I, �� I ■ 1„0, I ' R_.I MMempl tde w lbr -'",1 ss�- SI =:ns"°OK _ /1R II 6o,asanwoxraeona.°4- ■■ 1 nfie, ----'--- ipodapmaad,ol lif 13,EJoar"n"�r, n-tsrszeu)Goo pipe 0 1-nnznzal MI -19/32.. 7&37/32(1821L'quid pips U 61n6(131) 5-6132)131) Undr ode / ), 1 - 7 i 11111111/'����'({{■l Piping connection �re-=�: ,,,,,,,,,,„L„, /' S y Liquid pipe Refrigerant pipe:3/8 0.D(08.52)e / e Flared connection:318E Kripokp�tbde sleeve '041...4P,'"9 Refrigerant pipe:5/8 0.D(015.88) (publased Iocat)) Through hale 2'Gas pipe Flared connection:5/8F (075)5/16 d2-15/16`¢35/32 ()Drain hose 5/8 16 /075-080) (� )0.D Effective length:23-1/32(585) Required spec:On,toor unit) Airinlet 1 2 Knockout hole for prying Air outlet i1 ,I ill:- 'l• , II I Min.&21132'220 ��Min.331)32100. -2AH.451 �I-n2 1 �,.9n5 s�, Min.2-1H: 2.3 A Imo'%Ile a 13n21p.r I GMarmeaaumrr.15ple 43132 5 ud,loo(de)minaa I,_ , .17 "'. : a ',4 o '''''''''d n :fi i4e5r) t - 54� yy1 g$i ^ Indoor iavt outlim !IlInsIg1=MOO"OlOni=tf,Piltrr--.4 t1221 ,=_« gf w,■� l�si itlit r■e�il�i m=2, L18r„]riNt5 mal a f —~b15Wa8251 '1�8(15 e„.iiippi.7.2mai oyfW��l� ��i)NB�.51 Lara,rz 3G'—' Ltata.e %,�end,U semen fR51 -,ring k■ e,raj s .�[:�C3_: Olt 7"1 ILLI\�!,oi�xu nln.5 _ - � _.� �=r�►�r.�� n.,maa • ••11=111111111111111.___I_luNil_\I= 8 a '1 S P l '- gig i 8 t. rbara,p Nsarwle. Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. PUZ-A36NKA7(-BS) Unit:mm<in> 1 FREE SPACE(Around the unit) 2 SERVICE SPACE 3 FOUNDATION BOLTS 4 PIPING-WRING DIRECTIONS Rearar imaHe n �rw v ,�4 :, The diagram baba shawsa bask erampk. gmervionsmspace neetletl Phase secure the unit grmly cant antl wiring mnnreSion sauluea4.l Exeninthe esf kuhrdeneabe forservukebeasare wakeandcreetnens m yth be 0>)hoMs. gYaen in Ne nstaletion manuak etc, can be rrede from 4 direpions: =5,84771, -21-.... mmxran sham mMe helvw tliagrem (Bp's atM vsshers mug he FROM,RgM,Rear antl Below - C a� Purdlased',AO) I/Anunluiu • Side ar Intake ¢ountleEan bort hephb '1 .214‘1.1°,'' b. ro _= e aaroia,arge .brt w.r� II. =,D 1050 041-11520 Sdelntke Art 362 14.1/4 Rearyrinake k h 11 05 a) —b ' _\ye.P.. V a irllli IAAv I Example of Notes .,_ IRII'llhlI ilii' IMPIJil S1 ..Rernserantansoicemnnemm;aSREI blsse;5eSl __U.. llillllii P I�I I�III 4efngerent 000ID ppe wnre of�FLaRS D&5^-islaFl __ Ih�I 4rvke Anel •1...Intlinacm.d STOPVALVE connec5on'aacer . Il 11'11''' UIIlIII ii Handle for D_ IIIAaI IIIIII a fdiIlVHandle formwinp ni ii I!II I�iI Ilii Nndkfor BO n rti'Illi 111 lllDlli "' m ' p , � IIIIIIiI lhlIJ111!li l'-'8 ".�'R = >-0_ a 11lhlll'�i�It l!!II I ©O - - P IIIJ II IIIIII,M. llll1,1 I, I n �g 4'x111' — Piping Knockout Hole Details , Front con cover ten.Me ..,,,-3.' vw PrxNrbMo�ek, C rile .we> . Rear piping cover n;i ey n6.N ;12 bk / Int1 rlW .@ @ /111r,,,-- ?a " .,,;,1gS' �. .11111115 rsl " .� :moi ^�re�_ =1. uu-,::,,_.!211041112111211! n%nam v.,srav • MITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard,Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com 14121 4ERT[F ,9- c�I us FORM#PKA-A36KA7/PUZ-A3ONKA7(-BS)-201810 Inte tele Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved.