Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (99)
MacDonald-Miller FACILM SOUITIONS. We make buildings work better November 19, 2018 Proposal# 18-1137AE Kristine Klupenger Oregon Education Association 6900 SW Atlanta St. Portland, OR 97223 FEB 19 2019 Site Address: 6900 W Atlanta St. Portland, OR 97223 ;j Ili or Subject: OEA Server Room Unit. MSIOr% Dear Kristine, MacDonald-Miller Facility Solutions is pleased to provide you with the following proposal to add mini split cooling in Server Room.This proposal assumes this work can be done during normal hours. INCLUSIONS: > Provision of new AC wall unit at left wall. (Nominal 2 Ton) o To be placed approx. 6' off floor level. ➢ Provision of new AC outdoor unit on ground level outside of the window by copy room. o Electrical by others. > Provision of thermostat for new unit. FFICEv > Provision of refrigerant lines from indoor to outdoor unit. o Includes UV resistant cover for exterior lines. CITY OF TIGARD o Includes cover for outdoor lines REVIE D FOR CODE COMPLIANCE > Provision of new condensate drain line. Approved: I > Leak check, vacuum, and charge to factory specs. OTC: [ ➢ Start-up and check unit operation. ➢ Permitting and Permit fees. Permit#: m „C, r�d g T OQ ) 405- > Two year parts and labor warranty(See below). Address: (,,,q 00 S‘..r A+) �h7� Suite#: By: Date: :\_275-- Lead \_ —Lead time on equipment at least 3 weeks. Regarding payment: Preferred payments made by check. As of March 2018, please note that use of credit card for payment will include a surcharge of 3% of invoice, we accept Mastercard and Visa. Note: MacDonald-Miller would provide a full two-year parts and labor warranty on above work provided we perform the maintenance on the equipment. mama ter.com 1-800-962-5979 WASHINGTON &OREGON . A VERTIV. LIEBERT SRC CABINET DIMENSIONAL DATA SRC INDOOR UNIT Return Front Panel 47:-•-Q`'`.���\ Air Grille 1`Od, _ -.1114-,4041,,,,,...,` 46 7/8" i::..'' '''--- -- .-.All . 1.-IF i"=- Il .1:M !,q.011.-Will11.11111n7111017.1...... .Allikimillall0-h.11110'..„.0 41/8" 7,, ;;; ,r r,, 1-, (105mm) (10 7/16" 265mm)8" I 203mm) 0 13 5/8" I 346mm) ) ,m ;444- MIIIIIIIIIIIIIIIIIIIIIt 4" H: 6112" 211/32" (64mm�11 (102mm) (165mm) (60mm) Shaded areas indicate recommended clearances to be provided for component access and filter removal. 40 9/16" — 1 1030mm) — Display and Signal Receiver / ..... - - . - - - e..11 DPN003783 REV: 1 Page:1/1 REV DATE: 7/17 0 vERTIV' LIEBERT SRC CABINET DIMENSIONAL DOORUN UNIT SRC24 OUTDOOR (.--------------___ , 34 1/4" (870mm) .... 21 1/2" I ;f-1,,4,,/%,.‘'4t:,;:•,;1:;';,:;..‘,,1-/-4g(1&,5,,,,,4,"/46.(m,,,,ml.Ve.., Ty p• (;g6mm) 4f:0 ;414f1y6; ? / 24 y— ( 5MM) r _--(610.'A m4‘4•'mh.:6 14 3 0.., '1,-'--.--'------.fiii) )),) b 7 ___ wt , 125/8" (321mm) (360mm) 4°4%4. • r,1 0A /:.„.,;;,,,4%,;:.,.,• Ewa ,/ oz,,/;,,,A4,-v/ip•,/, „•,/ k. / , ,„ ,,„.,,,,,,,, ,,,,/,,,/:•,e;;•:/‘ : i_.— ......„—/--,,,•• -1P,1/6,,,,,,,,,.. ,420, 4ft' „,•,/ - ""••%,,• ;"*'.•t,•";zorltik-.-:',44. -.4,,,,4:i-•.;:,-;:',:11;I ,,-,,# 0,„i,•::,w;;;,,k:;1,:g-gi , , •',,,,,,,.,:,:;,r,,,,,y, %,. .TL...' *'.'..-- ..-...'*....'..-.. .:...' >-------'..--. — ,,,,,,,L4,,,...%•,,,u5,.,•.iox‘,„,,,,,„„ '', 4 4. %ii. ... 31/32" f /\ 12 5/8" (321mm) (24mm) - 24" ,./,,, /,‘ (610mm) • %;;','"'/ / ,,,/, ,-;' ,,-,•,4,/,'iA';',413',7, 4.7 - ,. ,0'5%/7--.,; ,. ",•g,,...;; ;:),;',,,i/ ; zi, e— • . • = srlillii3, _...,•.---=.-:-- gi \ 311/2 ii-• 't -_'-- --,• \-0 ,1 (900mm) 7 r r(//;//;'?---S 14,1\\, , il, /(• e , 30 27/32" kV ,(,(,(1 ':01‘,/, ,;,');/),'i (783mm) 1 ' ktk"\ ‘ -'-1/-:;//i! 1 ii ....__, ‘,.._- ...----•-:---__;_/_...---- -, 15 7/16" (392mm) °Id Note: ViewREV: 1 not to scale. imt? ADimension REV D q ATE•• — /17 I View 0 (523012m9/m3 9" Front ew DPN003786 Page:1 /1 A VERTIV LIEBERT SRC PIPING SCHEMATIC SRC24 UNITS Indoor Unit Outdoor Unit 2-Way Valve I Liquid Side 12-Way Valve D4 7 — -B. EEV i TH1 ' ' TH2 I I I I I I Heat Exchanger Mr Heat Exchanger TH5 Evaporator Fan © Condenser Fan I I I 41IReversing TH4 Valve I � — � � 0 i 2-Way Valve Gas Side 2-Way Valve Accumulator' ,TH3 COI I — — Compressor Cooling — Heating Thermistor Description PCB Connector TH1 Suction air temperature thermistor CN-TH1 (Indoor) TH2 Evaporating middle temperature thermistor CN-TH3(Indoor) TH3 Discharge pipe temperature thermistor CN-TH3(Outdoor) TH4 Condensing temperature thermistor TH5 Outdoor air temperature thermistor CN TH2(Outdoor) DPN003789 REV: 1 Page:1 /1 REV DATE: 3/17 0 VERTIV LIEBERT SRC TERMINAL BLOCK CONNECTION LOCATION SRC24 UNITS Factory Wiring Field Wiring / / GN/YL B \ BL\ TERMINAL AL 1(L1) 2(L2) O 1(L1) 2(L2) 3 Control _ Cover v______ I I GN/YL A �I BRI BLI GN/YL I BRI BLI RDI /� In100>,0,:i f i i i i v I i I ------- /i l‘i 11,4 J J v j /i POWER - - TO INDOOR UNIT Electrical Wring r � Knockout ' Bottom Panel 4 i I 1, ((-- ( S150 ‘1‘ 1(L1) 2(L2)- 3 4%. ,e-s-9 5-717;91-_1! --1 64 \ % li 3 Upale. i ___ 11. - I ——_— Grounding - �ETAIL A ' I I l«)jIMI. Calill 1 Cable - Lmir WA). lino I Terminal Block Power pm Connection Cable A ) DETAIL A I „:1 Power Cord I � `r�i To Outdoor Unit ' r Conduit Panel I 1 .,:' ,,I::`I_� Connection/Communication 1 Cable(leading to indoor unit) DPN003794 REV: 1 Page:1 /1 REV DATE: 3/17 A VERTIV LIEBERT SRC WALL MOUNTING BRACKET SRC24 INDOOR UNIT 6 9/16" 33 25/32' 6 9/16" (167mm) (858mm) (167mm) f r 1 o o 0 0 0 il i ° ° 0 0 This of erledge thanee no ° closer to edge o ^ c ) o .. c ) o o 0 0 0 C3 0 ,s0" ° 0 0 13 -3/8"(340mm) o 0 - c o o v° o00 o o.^ icc : ° V 0 c2 o o i ° ° ° c o17TY7P/3•2"c "°" o c V 10 U oO (437mm) ....7--m,--Th ° LOD Right Rear o O o O o O .../=1, Piping o (43mms 0 0 _JDo . Tip. This edge to be no0 (217/32 closer to edge yp. ) of wall than 10-5/8"(270mm) __ 4 23/32" T _j,,„ YP• L J Left Rear Piping Unit Outline DPN003795 REV: 2 Page:1 /1 REV DATE: 3/17 A VERTIV LIEBERT SRC UNIT WALL DISPLAY 1. Operation Indication ®�—row CEMRALCAMROL 2. Set Temperature Button moi✓/ EUy —HIGH TERUNKR OFE `�"°�t 1^ nn OC BBB= PRE-FROSTG 3. Fan Speed Button 1 r BBB MEO �+, OERtOST Amp 1=12 W_NOT APPLIED (�j) (ry Low SCHEDULE `i' u 4_,.. O TEMPORARY 4. Setback Button '�"�'.I� IJ�.B—aero SVETRACK GGN 5. Operation-mode Select button e _ -C_���W1/R ®" ;rTHU;,ca>, SIMPLE I[ SLEEP II WEEK H HOLIDAY j 6. VYlreless Thermostat Receiver Eta;OAMBB;BBmif.ON OCCUPIED COPY A MI 3 �i�ri rr PM as hr. OFFUNOCCUPIED PASTE (not included on some models) 0 I ANGLE If 23 aALLSTD� IELGRIL°�] I LOCK ipO� �i 7. Sub Function Button LOWHIGHPOW I AUTO 11 (:ET II STEEREE it TEMP II EER �y9 SE ME © 8. Ventilation button 0 9. Reservation Button OSUB l © 10. Air-flow Button COpy ' "pot° FAN SET 11. Cooling Temperature Selpoint ;M�}, �-.� OK SPEED BACK 12. Function Setting Button �' COOL CLEAR TEMP 13. Up,Down, Left, Right Buttons 0 1< H' L V j ® OPER MODE 0 14. On/Off Button V ESC OVERRIDE 15. Heating Temperature Seipoint 16. Set/Cancel Button moi • 17. Exit Button ® m m O 5 Electrical: Power from the indoor unit Dimensions: 4-3/4"W x 4-3/4"H x 5/8"D Operating Temperature:32-104°F Storage Temperature: -4-176°F Humidity: 0-90%(non-condensing) Basic Functions: Room Temperature Display Operation-On/Off Mode-Auto/Cool/Dry/Heat/Fan Only Occupied cooling and heating setback temperature setpoint Fan speed-Auto/Low/Med/High/Power Discharge vanes-Auto/Swing/Fixed Controller lock function Static Pressure installer setting Error code display during unit or system malfunction Auto restart on power failure Advanced Functions: Time of day scheduling,5 events per day with control of occ/unocc,on/off mode,setpoints,and fan speed Minimum difference between setpoints(0-10°)adjustable deadband Setback button Timed override button Hold Occupied/Unoccupied Setpoint range lock Guard timer DPN003400 REV: 1 Page:1/1 REV DATE: 9/17