Report
FS Catalog -Small Building Fire Alarm Solutions Life Safety & Communications , i064 Intelligent Life Safety System s... , E � FDNY ii r y 00"020 00) 7165-1657: 0244 O • S3000 Overview Features The Edwards EST i064 intelligent life safety system offers the • Comes standard with one loop that supports up to 64 power of high-end intelligent processing in a configuration that intelligent devices of any type and two Class B NACs. delivers an uncomplicated solution for small to mid-sized applica- • Supports Signature Series modules and detectors tions.With intelligent detection,electronic addressing,automatic device mapping,optional Ethernet®connectivity,and a full line of • Combines the Signature intelligent releasing module with easily-configured option cards and modules,this flexible system Signature multisensor detectors for reliable suppression offers advanced features that benefit building owners and contrac- • Form C for Alarm and Trouble, Form A for Supervisory tors alike. • Electronic addressing with automatic device mapping The i064 provides one Class B analog device loop that supports • Optional Ethernet port for diagnostics,programming and up to 64 device addresses,and two Class B Notification Appli- variety of system reports ance Circuits(NACs).Optional Class A device wiring is available with the use of a module. • Two programmable switches with LEDs and custom labeling • This life safety system features an attractive design that fits with Supports Genesis horn silence over two wires and UL any decor. Its distinctive doorfront offers a contemporary look 1971 compliant strobe synchronization that's available with red or silver finishes.All LED indicators and its • Supports up to eight serial annunciators,(LCD, LED-only,and large backlit display remain easy to see at all times. graphic interface). The iO64 supports a wide range of accessories and related equip • Can use existing wiring for most retrofit applications ment, including: • Upload/download remotely or locally • Signature Series intelligent modules,detectors,and bases • Two-level maintenance alert reporting • R-Series remote annunciators • Pre-alarm and alarm verification by point • option cards that expand system capacity and extend system • Adjustable detector sensitivity capabilities • 4 x 20 character backlit LCD display • fully integrated CO detection using Signature Series 2 detec- • Optional earthquake hardening:seismic Importance Factor 1.5 tors with or w/o audible signaling. Page 1of10 DATA srMr 85005-0131 Not tr,=,e used for sn t tl3, = g5urp€seer, Issue 7 Application Operation The 064 life safety system is a powerful intelligent solution for small The front panel provides an MINIM to mid-sized buildings.Advanced analog technology delivers the easy-to-use operator's inter- benefits of flexible system installation,while a clean and easy-to- face,as well as all the neces- Kim operatate user interface makes panel operation and system mainte- sary controls for front panel Kim 1r of Cit nance quick and intuitive. programming.A large back-lit li1 iI— oai ®I80-character LCD displays 0f � tai t The smart choice system status,event details, (-) ©i' Signature Series electronic addressing eliminates the tedium of and programmingprompts. Nu I ® setting dipswitches,and automatic device mapping ensures that Large tactile control buttons al each device resides on the system at its correct location. Mean- are easy to see in low light 8li I ®®® while,innovative programming features allow the system designer conditions,and bright multi- I �' s` to customize powerful built-in features to precisely suit the needs color LEDs offer at-a-glance 8 00C3 of the building owner. status indication. $l1 ® Flexibility built right in Two fully-programmable front panel switch/LED combinations pro- Control buttons vide an added measure of flexibility.Their slide-in labels take the Button Description mystery out of custom applications,and present a clean finished appearance. System Reset Initiates a system reset._ _ ACK/Panel Silences the panel and remote annunciators during Perfect for retrofits Silence an active trouble,supervisory,or alarm event and acknowledges new event activations. The i064 is particularly well-suited to retrofit applications.All Signal Silence Alarm mode:Silences active notification appliances. connections are made over standard wiring-no shielded cable Pressing Signal Silence a second time turns NACs back required.This means that in most situations existing wiring can be on. used to upgrade a legacy control panel to 0-Series technology Drill Initiates a drill confirmation.Pressing drill a second time without the expense or disruption of rewiring the entire building. turns off the drill function. Remote Dialer:Disables or enables dialer. Signals with a difference Disconnect Dialer set to modem only:Disables or enables the i064 NACs are configurable to fullysupportcommon alarm relay. g the advanced signal Left arrow Display mode:Moves the cursor to the left. ing technology of Edwards Genesis and Enhanced Integrity notifi Menu mode:Toggles between programming cation appliances.These devices offer precision synchronization of selections. strobes to UL 1971 standards. For Genesis devices,enabling this Right arrow Display mode:Moves the cursor to the right. feature allows connected horns to be silenced while strobes on Menu mode:Retrieves a programming option's sub the same two-wire circuit continue to flash until the panel is reset. menu and toggles between a programming option's selections. Clear-cut remote annunciation Up arrow Display mode:Advances to the previous event. Remote annunciation is a strong suit of the i064. Up to eight an- Menu mode:Moves the cursor up. nunciators can be installed on a single system.Compatible annun- Down arrow Display mode:Advances to the next event. ciators include a range of LED and LCD models that provide zone Menu mode:Moves the cursor down. or point annunciation,as well as common control capabilities. Enter Display mode:Displays selected event details. Menu mode:Retrieves a programming option's sub The 064 also supports graphic annunciation with optional graphic menu or jumps to the Save function in the menu. annunicator interface modules. Each interface provides common Entry mode:Enters the selected data into the system. control, indicators,and LED drivers. Consult the Ordering Informa- Cancel Display mode:Exits the detailed information display. tion section for details. Menu mode:Exits the current menu level. Entry mode:Clears the current entry. Menu Display mode:Enters the menu mode A complete line of accessories Menu mode:Exits menu mode The 1064 life safety system is supported by a complete line of Space Enters a space,such as a space between words. intelligent detectors, modules and related equipment.Consult the Alphanumeric Entry mode:Pressing a button once enters the number Ordering Information section for details. keypad on the button.Pressing the button twice enters the secondary value. Programmable These buttons can be programmed to control outputs, buttons disable devices or unlatch system outputs. Page 2 of 10 , - 85005-0131 Not to be usoG -,Aation purpose , Issue 7 System LEDs Panel Operation Options LED Description Language English or French Alarm Red LED. Flashes when there is an active alarm Marketplace U.S.or Canada event on any loop.On steady once acknowledged. AC fail delay Off:Off-premise notification of an AC power failure Trouble Yellow LED. Flashes when there's a fault with a is immediate. monitored circuit or system component or when a 1 to 15 hours:Delays the off-premise notification of circuit is disabled.On steady once acknowledged. an AC power failure by the time period selected. Sup Yellow LED.Rashes when there is an active super- Zone resound On:NACs resound each time a device in the zone visory event on any loop.On steady once acknowl goes into alarm even if they were silenced edged. Off:Inhibits the NACs from turning on again(after they were silenced)when a second device in the Ac Power Green LED.On when the panel has AC power. zone goes into alarm. Disable Yellow LED. Double-flashes when there is a dis- Reset inhibit after Off:Panel reset is operational immediately. abled circuit, alarm relay,or remote annunciator. NACs turn on 1 minute:Panel reset is inhibited for one minute. Ground Yellow LED.On steady during an active ground Auto signal Off:Allows immediate silencing of signals from an Fault fault. silence off-normal condition using the Signal Silence button Test Yellow LED. Flashes when performing an audible 5 to 30 minutes:Delays the silencing of signals walk test.Steady indicates a silent test. from an off-normal condition by disabling the Signal Monitor Yellow LED. Flashes when there is an active monitor Silence button for the time period selected. event on any loop.On steady once acknowledged. Day start Start time for daytime sensitivity Service Yellow LED. Indicates that detector needs servicing. Night start Start time for nighttime sensitivity Detector Date U.S.:MM/DD/YYYY,Canada:DD/MM/YYYY Signal Yellow LED.On steady indicates that NAC circuits Sounder Base Six configuration settings Silence are turned off but the panel is still in alarm. Mapping Disabled:Device mapping is not available Remote Yellow LED.On steady indicates that the dialer is Enabled:Device mapping is available Discon- disabled or that the alarm relay is enabled or dis- LCD banner Banner text for line one and line two.Each line is nect abled when the dialer is set to modem only. capable of up to 20 characters. Drill Yellow LED. Indicates that the panel is in drill. Event notification Zone:When a device is a member of a zone,only Reset Yellow LED. Indicates that the panel is resetting. the zone information is sent to the LCD display, Panel Yellow LED.Indicates that the panel has been LEDs,printer,and dialer. Silence silenced during an active trouble,supervisory,or Zone/y andde:ZoneD . information Device information is sent isto the LCD display LEDs. sent to the alarm event and indicates that new event active- printer and dialer. tions have been acknowledged. Device:Only device information is reported. User Keys Yebw I Fr).Indicates the programmed key function is active. Dimensions Programming Surface mounting holes i0-Series life safety systems are simple to set up,yet also offer ad- 14-D2- 1 L D3 vanced programming features that put these small building panels into a class of their own.The auto programming feature quickly 0 0 0 `0 gets the panel operational using factory default settings. Basic '` e ° zone and point settings can be programmed easily through the if 0 . front panel interface,so the system is up and running in no time. m For more advanced system configuration and correlation groups II f ll cn programming, i0-Series systems interface to a PC running com- E patible i0-CU software.This option offers full system configuration °el D1 o in the familiar Windows®operating environment.Connection is p[ D4 E typically made to a laptop through the panel's optional RS-232 0 communications port,which can also be used to connect a sys- a . tern printer. E U © Among the many advanced features of i0-Series control panels is the optional network card.This module provides a standard Surface mounting holes10/100 Base T Ethernet®network connection that permits access 5 to the control panel from any remote location with the correct • communications protocols.The connection can be used to 1L____D6 download to the panel from the i0CU,or upload and view system 4 D5 reports using the i0-CU. Available system reports include: Paneldimensions,.in • Correlation groups • Device details Model D1* D2 D3 ' D4 ' D5* D6 • Device maintenance • History i064 21.50 3.85 7.5 15.5 14.25 10.25 • Internal status • System configuration (54.6) (9.8) (19.0) (39.4) (36.2) (26.0) • System status • Walk test *Add 1-1/2 in.(3.81 cm)to D1 and D5 dimensions for trim kit. • Dialer • CO runtime Page 3 of 10 ;A SHEET' 85005-0131 N+{YI to he:.F -.s for installation purposes, Issue 7 Wiring & Configuration Alarm,trouble,and supervisory relay(TB3) Notification appliance circuits(TB2) The trouble relay is normally-open, held closed,and opens on any trouble event or when the panel is de-energized.The supervisory The i064 comes equipped with two notification appliance circuits. relay is normally-open,and closes on any supervisory event.The Each circuit can be individually configured for continuous,tempo- alarm relay changes over on any alarm event. ral,synchronized, latching,and coded output. Relay specifications Circuit Specifications Alarfn i Trouble Supervisory Crcuit Type 2 Class B,Class A optional when Class A card is installed. Typee Form C Form A Each circuit is 2.5 amps. Voltage 24 VDC at 1 A resistive 24 VDC at 1 A resistive Voltage 24 VFWR Relay circuits can only be connected to power-limited sources. Current 3.75A total(115/230 60hz) 3.0A total(230v 50hz) 2.5 A max per circuit Auxiliary&Smoke power outputs(TB3) Impedance 26 0 total,0.35 pF max The control panel provides two auxiliary power outputs which can EOLR 15 K 4,Y2 W be used for powering ancillary equipment such as remote an- nunciators and two wire smoke detectors. Aux 2 can be software selected to operate continuous.The circuit is supervised for shorts Class B wiring and grounds. 0 NAC1 NAC1+ + + < h Note: For a complete list of devices that can be connected to this EOLR circuit, refer to the iO Series compatibility list(p/n 3101064). 0 NAC2- + mAC2+ a a NCirouit SPeCifiCatiORS Circuit voltage range 21.9 to 28.3 V t3illr1cing indicates output signal polarity when the circuit is active. Resettable circuit 24 VDC nominal at 500 mA Polarty reverses when the circuit is not active.Wire notification appliances accordingly.Notification appliance polarity shown in (Aux power 2) active state. Continuous circuit 24 VDC nominal at 500 mA.Use this circuit for (Aux power 1) powering two-wire smoke detectors. Note:Any current above 0.5 amp connected to both Aux 1 and 2 will reduce the total Signature Device loop available NAC power by that amount. The system provides one device loop circuit that can be used with any mix of Signature Series detectors and modules.The loop circuit is supervised for opens,shorts,and grounds. Annunciator loop(TB4) The Signature Loop Controller uses broadcast polling and ad- The control panel provides a connection for up to eight serially vanced communications formats to regularly check the entire driven and supervised remote annunciators. device circuit for anomalies. If a change of state is detected at the circuit level,the Loop Controller then uses a direct address search Prcuitspecifications to find the reporting device,This two-staged technique ensures Device loops Class B(Style Y)or Class A(Style Z) that only new information is transmitted,thus allowing for a re- Circuit voltage 2.55 V duced baud rate while still achieving nearly instant device reporting. Circuit current 30 mA max Circuit Up to 8 annunciators or 4000 feet impedance Circuit Specifications Device loops 1 loop Class B,Class A optional when Class A card Class B Class A is installed.Supporting up to 64 device addresses. Communication Maximum 20 V peak-to-peak Channel 1 Channel 2 Channel 1 Channel 2 line voltage + — + — + — + — Circuit current 0.5 A max is c si ®TB4 ® ® i &TB4 Circuit 660 total,0.7 pF,max Annuncator Annuncator impedance &CHI(+)IN ®CH1(+)IN Isolators 64 maximum eCH1(-)IN ®CH1(-)IN CH2(+)IN ®CH2(+)IN Class B Wiring Class A Wiring ®CH2(-)IN t9 CH2(-)IN Loop 1 SEC —Data Line Looe 1 PRI + tires Loop Loop Loop Loop Loop card device device device device Data Line Page 4 of 10 DATA C H t i 85005-0131 Nci: U be i.€.serf for it letciiOtior,pi rpose:. Issue 7 Option Cards i0-Series panels are supported by a complete line of modules and SA-232 RS-232 interface SA-232 wiring related equipment that enhance performance and extend system The SA-232 card provides an RS-232 GND(black wire) capabilities.Option cards are easyto install and set up.Theyinterface with 0-Series panels. It can be TXD(wni wire) p p —RXD(red wire) simply plug directly into the control panel main circuit board or are used for connecting a printer to the control connected to it with a ribbon cable.After installation,terminals panel to print system events.The card also ®®�J remain easily accessible for quick connection of field wiring.The can be used for connecting a computer t +❑®® o cabinet provides ample room for wire routing,keeping wiring neat download a configuration program from 0 0 and easy to service at all times. the i0-CU to the control panel. The RS-232 card is installed on the plastic assembly and con- nects to the main circuit board via a ribbon cable. SA-CLA Class A Module SA-232 specifications The SA-CLA card Operating voltage Standard EIA-232 provides Class A SA-CLA wiring p g g capability for NAC, TB2 on main I�[L1 NAct_ ' Terminal rating 12 to18 AWG(0.75 to 2.5 sq mm) circuit board•�I .11/��' Operating environment loop, and an- IC��7l , p g Temperature 32 to 120°F(0 to 49°C) nunciator wiring. i��______� /" Humidity 0 to 93%RH,noncondensing at 90°F(32°C) Its terminal block provides the wiring EMU 11111 connection for NAC I[��]C return wiring.The Ulf SMK Smoke Power Converter •i IRF711 The SMK Smoke Power card is required for 24 VDC ClassAcard installed Converter Module provides a auxikary + I[ry2, loop and annuncia- Power —ICS, tor Class A wiring on main circuit board regulated power source for two- (not reaettabie) wire smoke circuits connected even though this wiring does not return to the SA-CLA card.The to a Signature data circuit.The IL]IT®( 1SA-CLA is compatible with 064 control panels only.i0500 panels SMK monitors the operating SMK T' are Class A ready.The SA-CLA is installed directly to the control power from the power supply. P°wet i" panel circuit board using its plastic standoffs and plug connection. Power out When power begins to degrade, a 3 2; SA-CEA specifications the SMK provides the necessary 0 L. J �. c i 0 Operating voltage 24 VFWR operating voltage to the two- wire smoke detection circuits. Tw°-wiresmoke Operating current 2.5 A/circuit,3.75A total(115/230 60hz) detectors 3.0A total(230v 50hz) ©IsO ®IhL_....'5)_._1_......_79 ® Circuit impedance 26 0,0.35 pF,max Terminal rating 12 to18 AWG(0.75 to 2.5 sq mm) JPt —pp+ Operating environment Temperature 32 to 120°F(0 to 49°C) `-r���®I ®®®I J Humidity 0 to 93%RH,noncondensing at 90°F paras n ;`i (32°C) Two-wire smoke~ detectors aISS,OrgIL IS0@ 1 16151013t�,�121110 a .....--- JPt — Terrninate SA-ETH Ethernet Interface Card or to next SA-ETH wiring °- UM The SA-ETH card provides a Ir—gg coon ection °`` © 7 standard 10/100 Base T Ethernet . I�e:�®J L����_��I Network cable •�• network connection for connect- Data out IVI ing to an intranet,a local net- j work, or the Internet.The card can be used to download SMK specifications PL7 configuration programming from Input voltage 21.9 to 28.3 VDC(not resettable) ® the 0CU to the panel over the Output voltage 24 VDC nom.at 200 mA,max.,special UO ®} network. applications 1 ®[ The Ethernet card is installed on Ground fault 10 k ohm �l the plastic assembly and con- impedance Ethernet card nects to the main circuit board Operating environment via a ribbon cable. Temperature 32 to 120°F(0 to 49°C) Humidity 0 to 93%RH,noncondensing at 90°F(32°C) SA E'f $p if tions I ,z Storage temperature —4 to 140°F(-20 to 60°C) Ethernet 10/100 Base T Compatible electrical North American 4 inch square x 2-1/2 in. Operating environment boxes (64 mm)deep 2 gang box or Standard 4 in. Temperature 32 to 120°F(0 to 49°C) square box 1-1/2 in.(38 mm)deep Humidity 0 to 93%RH,noncondensing at 90°F Wire size 14, 16,or 18 AWG wire(1.5, 1.0,or 0.75 sq. (32°C) mm)(Sizes 16 and 18 AWG are preferred) Page 5 of 10 DATA SHEET 85005-01 1 Nd t bets:d for install stio?s purposes, Issue 7 SA-DACT Dialer SIGA-REL Releasing Module The SA-DACT provides communications between the control The SIGA-REL is an analog addressable module that communi- panel and the central station over a telephone line system. It cates directly with the fire alarm panel Signature loop controller.The transmits system status changes(events)to a compatible digital SIGA-REL controls sprinkler,pre-action and deluge systems,and alarm communicator receiver over the public switched telephone may also be used to release extinguishing agents such as 002, network.The dialer is capable of single,dual,or split reporting Halon,or foam.The module is easily configured in the field and of- of events to two different account and telephone numbers.The fers a wide range of options that ensure dependable service,while modem feature of the SA-DACT can also be used for uploading preventing the unnecessary release of extinguishing agent. and downloading panel configuration, history,and current status to a PC running the i0-CU. SIGA-REL spec flcations SA-DACT Phone line 2 Input voltage 24 Vdc(power limited) wiring Phone line 1 To wall Supervisory current 25 mA,max. phone jack Power riser Riser input current 4 amps maximum Phone cables Alarm 170 mA min.;4 A max. (supplied) T i RJ31 jacks Output rating 2 A @ 24 Vdc(per circuit) LI',I W-1 Valves per circuit 4 valves,max. Release Max.supervisory current 0.4 mA(short circuit) u i The dialer phone lines connect circuits Nominal supervisory current 0.18 mA . -o ' Supervisory voltage 26 Vdc,max.(open circuit) '=I I'o n" to connectors on the dialer's °oQ 0 main circuit board.Phone line 1 End of line device 47k Ohm EOL C❑ ❑' connects to connector J4 and Output rating 2 A©24 Vdc(for each a ) phone line 2 connects to Max.supervisory current circuit III e e connector J1. Pre-release Nominal supervisory current 0.4 mA(short circuit) o❑❑®°®o a va� alarm circuits Supervisory voltage 0'18 mA o°❑❑_-5. 0M End of line device 26 Vdc,max.(open circuit) i=nn° 47k Ohm resistor IRP e Qoo$n e ° Max.supervisory current 0.4 mA(short circuit) Manual Nominal supervisory current 0.18 mA release input Supervisory voltage 26 Vdc,max.(open circuit) The SA-DACT queues messages and transmits them based on End of line device 47k Ohm resistor priority(alarm,supervisory,trouble,and monitor).Activations are circuit Circuit type Class B N.O.latching transmitted before restorations. Circuit capacitance 0.1 pF,max Max.supervisory current 0.4 mA(short circuit) The SA-DACT is installed on the plastic assembly and connects to Nominal supervisory current 0.18 mA the main circuit board via a ribbon cable. Supervisory voltage 26 Vdc,max.(open circuit) Abort circuit End of line device 47k Ohm resistor Circuit type Class B N.O.non-latching Circuit capacitance 0.1 pF,max SAWI + T spns First alarm 3 A@ 24 Vdc Phone line type One or two loop start lines on a public, output relay Contact rating (0.6 power factor)Form C switched network Phone line connector RJ-31/38X(C31/38X) Signature Operating voltage 5.2 to 19.95 Vdc Communication formats Contact ID(SIA DC-05) Data line Supervisory current 1000 pA Alarm current 1000 pA Operating environment Note:Output circuits are power-limited when the riser circu t is power-limited. Temperature 32 to 120°F(0 to 49°C) Humidity 0 to 93%RH,noncondensing at 90°F (32°C) i064 Control Panel © Signature Series smoke detectors • y. , Loop Controller i ❑M Signature Senes modules „COrnp attbie,DACRs �I .'.a .. .. Receiver Models Formats LJ� Ademco 685 Contact ID (' 4�y srobe°ir°°it FBI! CP220 Contact ID U i sD I Service Disconnec Sation Osborne-Hoffman OH 2000 Contact ID I A I Manual Abort Se on MR I Manual Release Station Radionics D6600 Contact ID 2 � First Alarm Output Relay Silent Knight 9800 Contact ID Fire Alarm control Panel i Sur-Gard SG-MLR1,MLR2 Contact ID y # �^ Auxiliary Releasing Module SD RELA-EOL Release Circuitl Power Supply (SIGA-REL) SD RELA-EOL Release Circuit2 I A IIMRI For detailed specification and ordering information on the SIGA-REL,refer to Data Sheet 85001-0531--Releasing Module. Page s of 10 ATA S S t 1 85005-0131 Not to be need for ittata)Iation urposea. Issue 7 Specifications Device loops 1 loop Class B,Class A optional,supporting Batteries Batteries must be sealed lead acid type only. up to 64 device addresses Maximum charging capacity=26 Ah. Notification appliance 2 Class B,Class A optional,2.5 amps each Loop circuit Maximum loop resistance:66 0.Maximum circuits loop capacitance:0.7 pF Style 4,6,and 7 Power supply 3.75 A FWR total at 120/230 VAC 60 Hz wiring.64 isolators maximum 3.0 A FWR total at 230 VAC 50 Hz Loop circuit max detector 1.5 mA(see the UL and ULC compatibility list 0.5 amps aux power standby current for your panel for the maximum quantity of NAC Operating voltage 24 VDC.NAC minimum voltage:19.5 VDC @ detectors per circuit) 20.4 V battery voltage Compatibility ID 100 Loop operating voltage 20 V peak-to-peak Alarm contact Form C 24 VDC @ 1 A(resistive load) Primary power 120 VAC,60 Hz,230 VAC 50-60 Hz — Trouble contact Form C 24 VDC @ 1 A(resistive load) Aux Power 1 24 VDC nominal at 500 mA.A SMK module is Supervisory contact Form A 24 VDC @ 1 A(resistive load) (Continuous circuit) required when using the SIGA-UM module to Environmental Temperature:0 to 49°C(32 to 120°F). support two-wire smoke detectors. Humidity:0 to 93%RH,noncondensing Aux Power 2 24 VDC nominal at 500 mA. Terminal rating All terminals rated for 12 to 18 AWG(0.75 to (Resettable circuit) 2.5 sq mm) Auxiliary output 19 to 25.7 VDC Serial communications Voltage:2.55 V.Current:30 mA max Base panel current draw Standby: 155 mA Alarm:204 mA Remote annunciator 8 drops max,RS-485 Class B,Class A Battery placement i064 cabinets accommodate up to 10 NH Input zones 16 max. batteries.Use an external cabinet for larger Agency Listing UL864,UL2017,CSFM,ULC and NYFD battery sizes. COE#6020 Ordering Information Part Description Option Cards :r i064 Intelligent Single Loop Analog Systems SA-DACT Dual Line Dialer/Modem,supports 4/2 and Contact ID, iO64G 1 Loop System,64 point capacity,2 Class B NACs,gray mounts in cabinet on base plate. door,surface mount enclosure,115 Vac,English. SA-232 Serial Port(RS-232),for connection to printers& _.—>iO64GD 1 Loop System,64 point capacity,2 Class B NACs,2 computers,mounts in cabinet to base plate Line Dialer,gray door,surface mount enclosure,115 Vac, SA-ETH Ethernet Port,Slave,mounts in cabinet on base plate. English. SA-CLA Class A adapter module.Provides Class A capacity on iO64R 1 Loop System,64 point capacity,2 Class B NACs,Red NACs.Mounts in cabinet on main board. Door,surface mount enclosure,115 Vac,English. D16L-i0-1 LED Annunciator module,16 X 2-LED zones(4 max iO64RD 1 Loop System,64 point capacity,2 Class B NACs,2 programmable for sup). Mounts in cabinet to left of LCD Line Dialer,Red Door,surface mount enclosure, 1-15 Vac, display for zones 1-16. English. D8RY-i0-1 LED Annunciator module, 16 X 2-LED zones(4 alarm iO64G-2 1 Loop System,64 point capacity,2 Class B NACs,gray (Note 1) only,8 supervisory only,4 alarm or supervisory). Mounts (Note 2) door,surface mount enclosure,230 Vac,English. in cabinet to left of LCD display for zones 1-16. iO64R-2 1 Loop System,64 point capacity,2 Class B NACs,Red (Note 2) door,surface mount enclosure,230 Vacr,English. Ftarr►ote Annunciators(refer tQ Data Sheet 85006.01;*, iO64G-SP 1 Loop System,64 point capacity,2 NACs,gray door. LCD Remote Annunciators(mount to standard 4"square box) (Note 2) surface mount enclosure, 115 Vac,Spanish. RLCD Remote Annunciator,4X20 LCD&Common Indicators iO64G-2-SP 1 Loop System,64 point capacity,2 NACs,gray door. for displaying system status.White housing. (Note 2) surface mount enclosure,230 Vac,Spanish. RLCD-R Remote Annunciator,4X20 LCD&Common Indicators iO64G-PG 1 Loop System,64 point capacity,2 NACs,gray door. for displaying system status.Red housing. (Note 2) surface mount enclosure,115 Vac,Portuguese. RLCD-C Remote Annunciator,4X20 LCD.Common controls and iO64G-2-PG 1 Loop System,64 point capacity,2 NACs,gray door. status indicators.White housing. (Note 2) surface mount enclosure,230 Vac,Portuguese. RLCD-CR Remote Annunciator,4X20 LCD.Common controls and iO64GL 1 Loop System,64 point capacity,2 Class B NACs,16- status indicators.Red housing. (Note 1) zone LED display,gray door,surface mount enclosure, RLCDF Remote Annunciator,4X20 LCD&Common Indicators 115 Vac, English. (Note 1) for displaying system status.White housing,French iO64GL-F 1 Loop System,64 point capacity,2 Class B NACs,16- RLCD-CF Remote Annunciator,4X20 LCD.Common controls and (Note 1) zone LED display,gray door,surface mount enclosure, (Note 1) status indicators.White housing,French 115 Vac, French. RLCD-SP Remote Annunciator,4X20 LCD.Common system status SA-TRIM1 Flush mount trim,black (Note 2) indicators.White housing.Spanish. RLCD-PG Remote Annunciator,4X20 LCD.Common system status Rel acement EtectrOrttcs (Note 2) indicators.White housing.Portuguese. 64elec-i0 Replacement electronics kit,complete motherboard and RLCD-C-SP Remote Annunciator,4X20 LCD.Common controls and user interface,English (Note 2) status indicators.White housing.Spanish. ......... 64e ec-iO-SP Replacement electronics kit,complete motherboard and RLCD-C-PG Remote Annunciator,4X20 LCD.Common controls and (Note 2) user interface,Spanish (Note 2) status indicators.White housing.Portuguese. 64elec-iO-PG Replacement electronics kit,complete motherboard and GCI Graphic Annunciator Driver Master for R-Series (Note 2) user interface,Portuguese annunciators.Outputs for 32 LEDs,connection to 64elec-iO-FR Replacement electronics kit,complete motherboard and common control switches and LEDs. (Note 1) user interface,French GCIX Graphic Annunciator Driver Expander for use with GCI Masters.Outputs for 48 LEDs,24 switch inputs. Page 7of10 DATA SHEET 85005-0131 Not to be used for im&ta€iation purposes, Issue 7 LED Remote Annunciators&Expander(mount to standard 4" RLED24R Remote Annunciator Zone expander.24 X 2-LED groups square electrical box) with custom label areas for display of alarm and trouble. RLED-C Remote Annunciator.Common controls and status Red housing. indicators with 16 X 2-LED groups for zone display.White Remote Annunciator Cabinets&Accessories housing. RLED-CR Remote Annunciator.Common controls and status RA-ENC1 Remote Annunciator Enclosure,key locked with indicators with 16 X 2-LED groups for zone display.Red plexiglass window for one RLCD(C)or RLED(C). housing. RA-ENC2 Remote Annunciator Enclosure,key locked with RLED-CF Remote Annunciator.Common controls and status plexiglass window with space for 2 of either RLCDx, (Note 1) indicators with 16 X 2-LED groups for zone display.White RLEDx or RLED24. housing,French. RA-ENC3 Remote Annunciator Enclosure,key locked with RLED-C-SP Remote Annunciator,common controls and status plexiglass window with space for 3 of either RLCDx, (Note 2) indicators. 16 groups w/2 LEDs each for zone display. RLEDx or RLED24. White housing.Spanish. RKEY Keyswitch,single gang,provides key operated enable or RLED-C-PG Remote Annunciator,common controls and status disable of common controls on RLCD or BLED units. (Note 2) indicators.16 groups w/2 LEDs each for zone display.White LSRA-SB Surface Mount Box-for R Series single units. housing.Portuguese. RLED24 Remote Annunciator Zone expander.24 X 2-LED groups tramming Tots with custom label areas for display of alarm and trouble. i0-CU EST Series configuration and diagnostics utility. White housing. 260097 RS232 cable,4 conductor, DB9 PC interface Note 1-Available in Canada only.Note 2-Available in International markets. Analog Addressable Devices & Accessories Model Description Ship'wt. Model ; Desca tion Ship- Intelligent Detectors&Bases SIGA-AB4G Audible(Sounder)Base 0.3(0.15) SIGA2-PHCOS Intelligent Multisensor Photoelectric/Heat SIGA-TS4 Trim Skirt(supplied with 4-inch bases) 0.1 (.04) Detector with carbon monoxide sensor SIGA-AB4GT Audible(Sounder)Base for CO and Fire SIGA2-PHS Intelligent Multisensor Photoelectric/Heat Detectors 0.3(0.15) Detector SIGA-TCDR Temporal Pattern Generator 0.3(0.15) SIGA2-PHSB Intelligent 4D Multisensor Detector(Black)- UL/ULC Listed Modules SIGA2-PCOS Intelligent Photoelectric Detector with carbon SIGA-CC1 Single Input Signal Module(Standard Mount) 0.5(0.23) monoxide sensor 0.4(0.16) SIGA-MCC1 Single Input Signal Module(UIO Mount) 0.18(0.08) SIGA2-PS Intelligent Photoelectric Detector SIGA-CC1 S Synchronization Output Module(Standard SIGA2-HRS Intelligent combination fixed temperature/ Mount) 0.5(0.23) rate-of-rise heat detector SIGA-MCC1 S Synchronization Output Module(UIO Mount) 0.18(0.08) SIGA2-HFS Intelligent fixed temperature heat detector SIGA-CC2 Dual Input Signal Module(Standard Mount) 0.5(0.23) SIGA2-HCOS Intelligent fixed temperature heat detector SIGA-MCC2 Dual Input Signal Module(UIO Mount) 0.18(0.08) with CO sensor SIGA-CR Control Relay Module(Standard Mount) 0.4(0.15) SIGA2-COS Intelligent Carbon Monoxide Detector SIGA-MCR Control Relay Module(U10 Mount) 0.18(0.08) SIGA-HFS Intelligent Fixed Temperature Heat Detector- SIGA-CRR Polarity Reversal Relay Module(Standard 0.4 0.15 UL/ULC Listed Mount) ( ) SIGA-HRS Intelligent Fixed Temperature/Rate-of-Rise SIGA-MCRR Polarity Reversal Relay Module(UIO Mount) 0.18(0.08) Heat Detector-UL/ULC Listed SIGA-RM1 Riser Monitor Module(Standard Mount) 0.5(0.23) SIGA-IPHS Intelligent 4D Multisensor Detector-UL/ULC SIGA-MRM1 Riser Monitor Module(Plug-in) 0.18(0.08) Listed 0.5(0.23) SIGA-IO Input/Output Module(Standard Mount) 0.34(0.15) SIGA-IPHSB Intelligent 4D Multisensor Detector(Black)- SIGA-MIO Input/Output Module(Plug-in) 0.22(0.10) UUULC Listed SIGA-MAB Universal Class A/B Module(Plug-in) 0.18(0.08) SIGA-PHS Intelligent 3D Multisensor Detector-UL/ULC SIGA-CT1 Single Input Module 0.4(0.15) Listed SIGA-PS Intelligent Photoelectric Detector -UL/ULC SIGA CT2 Dual Input Module 0.4(0.15) Listed SIGA-MCT2 Dual Input Plug-in(UIO)Module 0.1 (0.05) SIGA-SD Intelligent SuperDuct Detector 2.4(1.1) SIGA-IM Fault Isolator Module .5(.23) SIGA-SB Detector Mounting Base SIGA-MM1 Monitor Module 0.4(.15) SIGA-SB4 4-inch Detector Mounting Base c/w SIGA-TS SIGA-WTM Waterflow/Tamper Module 0.4(.15) Trim Skirt SMK Smoke Power Converter Module 0.4(0.15) SIGA-RB Detector Mounting Base w/Relay SIGA-REL Analog addressable releasing module 0.52(0.23) SIGA-RB4 4-inch Detector Mounting Base /w Relay c/w Manual releasing station(single-action). SIGA-TS Trim Skirt 0.2(0.09) 276A-REL English markings,black text on yellow 1.0(0.45) SIGA-IB Detector Mounting Base w/Fault Isolator polycarbonate body. SIGA-IB4 4-inch Detector Mounting Base w/Fault Isolator c/w SIGA-TS Trim Skirt SIGA-LED Remote Alarm LED Page 8 of 10 T 85005-0131 t Oe used f<>r i �stallatio i noses, Issue 7 Model .. E sori• n .;. Ship wt Note: For earthquake anchorage,including detailed mounting weights and Manual releasing station(double-action). center of gravity detail,please refer to Seismic Application Guide 3101676- 278A-REL English markings,black text on yellow 1.0(0.45) EN.Approval of panel anchorage to site structure may require local AHJ, polycarbonate body. structural,or civil engineer review. RELA-ABT Manual Abort Station.English markings, 1.0(0.45) Standby batteries must be mounted externally from fire panel in separately black text on yellow polycarbonate body. mounted BC-1 enclosure.Order BC-1 aand BC-1 EQ separately. Service Disconnect Switch.One n/c contact RELA-SRV-1 and one n/o contact.English markings,white 1.0(0.45) text on blue polycarbonate body. RELA-EOL Polarized end-of-line relay.English markings 0.2(0.1) on stainless steel cover. SIGA-UIO2R Universal Module Board w/Riser Inputs-Two 0.32(0.15) Module Positions SIGA-UIO6R Universal Module Board w/Riser Inputs-Six 0.62(0.28) Module Positions SIGA-U106 Universal Module Board-Six Module 0.56(0.25) Positions 'Accessories GCI Graphic Annunciator Driver,provides outputs for common indicators and 32 alarm/supv zones as well as inputs for common switches. Provided with a snap track for mounting in custom graphic enclosures. CTM City Tie Module.Provides connection to a 0.6(0.3) local energy fire alarm box. RPM Reverse Polarity Module 3.0(1.36) BC-1 Battery Cabinet.14.0"x 18.25"x 7.25".Holds 50.0(22.7) 2 12V24A batteries. BC-1R Battery Cabinet-Red. 14.0"x 18.25"x 7.25 50.0(22.7) Holds 2 12V24A batteries. MFC-A Multifunction Fire Cabinet,8"x 14"x 3.5"- 20.6(9.4) RED. PT-1S System Printer-Desktop style. 36.6(16.6) BC-1 EQ Seismic hardening Kit for iO series panels. Includes battery hardening for BC-1 enclosure and components to harden panel internal components.See note. Page 9of10 DATA SHEET 85005-0131 hit t tos bo€t oa for ir�,t:ii tbop purposed. Issue 7 ct-DWAR DS 0....,16011611111$ Contact us... Email: edwards.fire@fs.utc.com Web: www.est-fire.com EST is an EDWARDS brand. 1016 Corporate Park Drive Mebane,NC 27302 In Canada,contact Chubb Edwards... Email: inquiries©chubbedwards.com Web: www.chubbedwards.com ©2013 UTC Fire&Security Americas Corporation,Inc.All rights reserved. Specifications subject to change without notice.Edwards is part of UTC Climate,Controls&Security,a unit of United Technologies Corporation. rn Page 10 of 10 . ::,3 , 85005-0131 be used for .,,as.,F;, Issue 7 ,„,„‘ . , DURACELL SLA Batteries ULTRAa ..... Duracell® Ultra SLA technology offers high-density power that out- performs traditional lead acid batteries.The Absorbed Glass Mat (AGM) construction is designed for efficient gas recombination and allows for ` " maintenance-free operation. Duracell® Ultra SLA batteries maintain their high capacity with a design ;•: that is resistant to damage caused by deep discharge. Every Duracell® Ultra SLA � �„" '�� . battery is inspected to ensure the highest standards in materials and fabrication. *\ ' e ave Cycles at 100% Discharge i_ r- ��� ,,, , , ., EL L . $ERCEf7[yiFN yP3t LA�StB�A` XRAY" fiS4 U� oupAC , .. L \\ , , i9SPILL ))D)))D?))T)))Y GUARANTEE Features: • Duracell® Ultra SLA GEL batteries contain a proprietary grid alloy formula combined with advanced plate curing techniques to provide maximum performance. • Duracell® Ultra batteries contain a unique electrolyte formula with a special sub-colloid additive for higher reliability and longer life. w • Will achieve more life cycles than standard AGM and Deep Cycle batteries. •The unique construction and sealing techniques of these batteries lACL are guaranteed to give you leak proof operation. ULTP,, • Heavy-duty lead calcium tin alloy grids provide an extra margin of performance and service life in cyclic applications, even after repeated over-discharges. • Quality Assurance Engineers monitor and control the entire production process. • Recycling of used SLA batteries available. LJE Mi CASE i �• Deliveryavailable. Quantities DD DAVAILABLE D Sealed ,. .,e,.. Lead 1. ,..... /I .. YEAR diam4 mol A c i d Maintenance Free Spill Proof 1 Year Stringent Quality Design Warranty Control batteriesplus.com 1-800-677-8278 PROJECT NAME: D U IAC ELL° SLA Batteries CATALOG# ULTRA FIXTURETYPE NOTES sa ': j ��� .; �'1..,:f.'''''' . R ;: FB" a r ���� .i.1$4;,;*:: a r ?i ,n DURA12-0.8WL 12V I 0.8 1 3.78 0.98 2.4 WL I - 0.77 DURA12-1.3F 12V s 1.3 1 3.82 1.69 2.28 I F1,T1 1 - I 1.37 DURA12-2.3F 12V 2.3 6.97 1.38 2.64 s F1 T1 2.04 DURA12-2.9F 12V I 2.9 3.11 2.2 3.9 F1,T1 - 2.36 j DURA12-3.3F F1 T1 3.18 URA12 3.3F 12V 3.3 5.28 2.64 2.63 DURA12-3.3F2 12V I 3.3 RAYA12 4F 12V I 4 3.54 2.76 4.21 I F1,T1 ; - - s DURA12-5F 12V 1 5 3.54 2.76 4.21 i F1,T1 - DURA12-5F2 12V I 53.56 2.77 3.94 - F2,T2 I DURA12-5.1A 12V 1 5.1 I 5.51 1.89 4.21 I Fl,T1 - 4.6 . DURA12-5.5F 12V 1 5.53.54 2.76 3.98 - - RAYA12-7F 12V 7 5.95 2.56 3.94 I F1,T1 - - s DURA12-7F 12V I 7 5.94 2.56 3.94 I F1,T1 - - DURA12-7F2 12V I 7 I 5.94 2.56 3.7 I F2,T2 - - i DURA12-8F 12V l 8 I 5.94 2.56 3.94 I F1,T1 - DURA12-8F2 12V 1 8 i 5.94 2.56 3.94 I F2,T2 . - - DURA12-9NB 12V 9 I 5.95 2.56 3.9 i NB,1 - - DURA12-9F2 12V I 9 I 5.95 2.56 3.94 F2,T2 j - __ a DURA12-10F2 12V I 10 I 5.95 2.54 4.38 F2,T2 - 7.5 DURA12-11NB 12V 1 11 1 5.28 3.15 6.5 - - 10.1 - DURA12-12F2 12V ; 12 I 5.94 3.9 3.98 F2,T2 - - DURA12-12F 12V I 12 j 5.94 3.86 3.86 1 F1,T1 - - DURA12-14F2 12V 14 5.94 3.86 3.98 F2,T2 - 8.91 DURA12-18F2 12V 18 7.13 3.03 6.57 F2,T2 - DURA12-18NB 12V I 18 I 7.13 3.03 6.57 NB,.1 - 12.43 DURA12-26NB I 12V 26 1 6.5 6.93 4.92 I NB,.1 - 20.7 DURA12-35C 12V i 35 7.72 5.16 6.5 1 C - 27.3 DURA12-44C/FR 12V 46 7.8 6.54 6.85 C 38 DURA12-55C/FR 12V I 55............................ 9.02 5.43 8.35 - 42.1 DURA12-80C/FR 12V I 80 i 10.24 6.65 8.46 I C - - DURA12100C/FR 12V I 100 I 12.09 6.65 8.46 I C 74.6 • DURA12-140C/FR 12V € 140 13.43 6.81 11.3 C 108 , DURA4-4.5F2 4V 4.5 ; 1.85 1.85 3.98 F2,T2 - 1.4 DURA6-1.3F 6V 1.3 3.82 0.94 2.28 F1,T1 - 0.715 ) DURA6 2ST 6V 1 2 ST 0.75 1.69 1.45 2.99 DURA62.9F 6V 1 2.9 I 2.6 1.46 3.82 I F1,T1 • - 1.26 § DURA6-3.3F 6V I 3.3 I 5.28 1.34 2.64 I F1,T1 - 1.65 , RAYA6-4F 6V i 4 I 2.76 1.85 4.13 I F1,T1 - - DURA6-5SP 6V 5 2.6 2.6 4.53 SP 2.09 DURA6-5F 6V 5 2.76 1.85 4.21 I F1,T1 - - DURA6-7.2F 6V 7.2.............................................5.94................................._1.34................................_3.68.......... F1,T1 2.43 DURA6-8.2F 6V 8.2 3.9 2.24 4.53 FIJI, .............................. . 3.8 DURA6-10F 6V 10 5.94 1.97 3.98 F1,T1 j - 4.851 DURA6-12F 6V 12 1 5.94 1.97 3.98 1 F1,T1 - • - • DURA6-12F2 6V I 12 5.94 1.97 3.98 I F2,T2 - I 4.602 RAYA6-14T2 6V I 14 1 4.25 2.8 5.51 H 6.24 DURA6-14A 6V I 14 I 4.25 2.8 5.51 ; Fl(-)F2(+),T1(-)T2(+),FP I - I 6.16 DURA6-42F2 6V I 42 1 6.25 3.37 6.37 I F2,T2 I - I 16.64 DURA6-42NB 6V I 42 i 6.34 3.43 6.42 I NB,1 I - I 16.62 3 DURA6-200C 6V I 200 I 12.05 6.65 8.63 C - - DURA8-3.2F 8V 3.2 5.28 1.44 2.48 F1,T1 1.65 Visit batteriesplus.com for warranty information ®2017 DURACELL,Bethel,CT 06801.Duracell is a registered trademark of Duracell U.S.Operations,Inc.,used under license.All rights reserved. Bulbs ' af,.clGg Po Annunciation EST Life Safety & Communications R-Series Remote o t Good Foal Annunciators RLCD, RLCD-C, _ED, RLED-C, RLED24 GCI FDNY �S3424 COOA 60A 6020 7120-16570254 : C87 Overview Features Edwards R-Series Annunciators are high-performance remote • LCD models feature large 4 x 20 character backlit LCD display annunciators that provide status indication and common controls • LED models provide 16 pairs of LEDs for zone annunciation for compatible fire alarm control panels, including i0-Series small analog fire alarm systems.This family of annunciators offers LCD • Available expander extends capability with 24 pairs of LEDs or LED annunciation. Models are available with and without com- • Up to two expanders may be wired to each annunciator mon controls. • Status LEDs and internal buzzer standard on all models There are three R-Series annunciator models,plus an LED-based expander. Up to two expanders can be connected to any annun- • Common controls available for LED and LCD display models ciator.The expander includes 24 pairs of LEDs that extend the • Available keyswitch for disabling common controls capabilities of any of the annunciators. • Standard 4-inch square electrical box mounting All annunciator models include status LEDs and an internal buzzer. • Class B or Class A RS485 wiring standard Two models have an LCD text display,and one has 16 pairs of LEDs for zone annunciation. LCD models feature a large back-lit, • One-,two-,and three-position enclosures available four by twenty character per line,super-twist liquid crystal display. • Graphic Annunciator interface, includes common control, indi- R-Series annunciators and expanders are mounted on a standard cators and 32 LEDS 4-inch square electrical box, using the included mounting ring. • No programing required,set the address and unit recieves all They can also be surface mounted in locking steel enclosures. information from panel Three different enclosures are available. A keyswitch and graphic annunciator interface is available for R-Series annunciator applications.The keyswitch enables or dis- ables common controls.The graphic annunicator interface cards supports 32 LEDs and 16 switches on the graphic panel display. Page 1 of aDATA t - 28 Not to be used for iotttaHiatio€a pu case, Issue 2 Appl:Ecation Annunciator Wiring R-Series annunciators communicate with the FACP on the RS-485 Annunciator, Class A data riser.This can be configured for Class A or Class B commu- FACP Annunciator Annunciator nication.Annunciators do not provide ground fault isolation. RS-485 —0 CH1(91N —0 CHI(+)IN These annunciators are stand-alone units that can be powered by CHI* 0 I 1 0 CH1(-)IN 0 CHI(-)IN the FACP or by an approved power supply. °H1 a °"'(`)OUT 0 CHI(+)OUT CH2+ O 1 0CH1(-)OUT OCH1(-)OUT J ., \ CH2- I OCH2(+)IN OCH2(+)IN '`\\\V �- - --O CH2(-)IN OCH2(-)IN I• uPew, LISTED 24 VDC 9 CH2(+)OUT 0 CH2(+)OUT SUPPLY 0 CH2(-)OUT 0 CH2(-)OUT o Tn...�a�� o.. 24 VDC+0_ —0 24V(+)IN —0 24V(*)IN ®®® ®. 24VDC-0 0 24V(-)IN 024V(-)IN c).— 9 24V(+)OUT 0 24V(+)OUT at aseEs- - Y 24V(-)OUT 024V(-)OUT 1-9--a DI e LI \ 0 GROUND - _L 0 GROUND RLCD-C BLED-C l/ \ 9 Annunciator, Class B °sem, s1 10 - eol 1°o FACP Annunciator Annunciator I$1 1$ RS-485 —0 CH7(+)IN —0 CH1(+)IN ®®I ) 1$I Io I 01 I o CH1+ 0— 0 CH1(-)IN OCH,(-)IN I SSI I eo CH1- 0 9 CHI(+)OUT 0 CHI(+)OUT 1p LSI I°o l CH1(-)OUT 0 CHI(-)OUT LL^i I" r � \\ 0 CH2(+)IN 0 CH2(+)IN �� �( �� �} O CH2(-)IN 0 CH2(-)IN RLCD RLED24 - �r LISTED 24 VDC 0 CH2(+)OUT 0 CH2(+)OUT Featuresby RLCD RLC -C FILE -C RLED24 SUPPLY OCH2()OUT OCH2(-)OUT 4-tea f 24 VDC+0- —0 24V(+)IN —0 24V(+)IN rn KIE4 _..._..... _ _::..__ ....._...._.__.. ._. ........_._.._._� 24 VDC-0 0 24V(-)IN 0 24V(-)IN Reset ✓ ✓ ✓ Ack/Silence ✓ ✓ ✓ c)24V(*)OUT 0 24V(+)OUT 24V(-)OUT 0 24V(-)OUT Fire Alarm ✓ ✓ ✓ - Supervisory ✓ ✓ ✓ - 0 GROUND _ 0 GROUND Ground Fault ✓ ✓ V - Trouble ✓ ✓ ✓ - Controls Enabled ✓ ✓ ✓ - Expander Ack/Silence ✓ ✓ ✓ - Reset / ✓ First Expander Second Expander - Signal Silence ✓ ✓ OUT IN OUT IN OUT Drill ✓ ✓ _ V(-)o GV(-) V(-)0 - --0V(-) V(-)0 V(*)/i /i V(*) V(+)0- - 0V(+) V(+)0 Lamp Test ✓ ✓ ✓ - Fp pF F0 - OF FO IIMLCD Display ✓ ✓ - - E// 6 E E 0- - ;--0 E E 0 Zone Active LEDs - - 16* 24+* D P. - /,D D 0- - i 0 D o 0 Zone Trouble LEDs - - 16 24 c, /,Cc 0 - c c 0 B /.e B0 - 1 8B BO +zones 13-16 may be selected as Supervisory on 1064 A o =II /,A A 0 - fl A A 0 "zones 13-16 and 29-32 maybe selected as Supervisory on 10500 Graphic Annunicator Interface The GCI Graphic Annunciator Driver is an interface card that Remote Ke switch connects the fire alarm control panel to the display panel of an Key switch graphic annunciator. Annunciator LSRA-RK The annunciator card supports 32 LEDs and 16 switches on the nKEYSWITCH(-)0 0 Tei-, Inil graphic panel display. It includes status LEDs and an internal KEYSWITCH(+)0 0 re,-2 buzzer. U The graphic interface is supplied with snap track mounting. It is Keyswitch Specifications attached to a plastic mounting rail that requires two EIA panels. Maximum 5 Vdc \mac l voltage The annunciator communicates with the FACP on the RS-485 Maximum 200 mA 1 N data riser.This can be configured for Class A or Class B commu- current nication.The annunciator does not provide ground fault isolation. Mounting 2-1/2 in(64 mm) IlliIt is a stand-alone unit that can be powered by the FACP or by an deep 1-gang box %iapproved power supply. Termination Screw terminals N Maximum 12 AWG ~aphic Annunciator Interface Specifications wire size (2.5 mm sq) Alarm current 146 mA at 24 Vdc(with 36 LEDs ON) �� Contact Normally open • Standby current 36 mA at 24 Vdc(with no LEDs ON) configuration Maximum current 10 mA per LED Page 2 of 4 DATA S EET 28 Nisi to be used for instal) tion purposes, Issue 2 Annunciator Connections Annunciator Mounting Annunciator ANNUNCIATOR RS-485 RISER slot /— Mounting ] Pc DI P switch Peeeeaee111111 � II ' r M"= 8 Remotekeyswitch ED RS-485 riser _ F""= terminals terminals = _ Powerterminals I a Expander cable o terminals O Communication _ LEDs ® o o "O ® ✓,�/' � o Expander 0 II •___ Mounting slot � o—D p 0 C I jl EXPANDER CABLE Expander cable 1 -1 _Expander cable terminals terminals o ® o � o DIP switch settings �� O Switch Description and values S1 to S5 The annunciator network address(in binary). Network The factory setting is for address 2. address Examples: 10000=1 01000=2 11000=3 00100=4 II S6 Network OFF=9600 baud(factory default setting) baud rate ON=38,400 baud S7 to S8 Not used MOUNTING RING EXPANDER ELECTRICAL BOX Annunciator Enclosures The RA Remote Annunciator Enclosures provide secure,surface mounted protection for annunciators and extenders. Each con- sists of a back plate, hinged cover,and key lock. The enclosures are 16-gauge welded steel with a white, painted 6.0 in finish. Each enclosure includes a security lock and two keys.The . 15.2 cm two-and three-position enclosures have wiring channels for cor- H rect routing of interconnections. The enclosures attach to a standard electrical box,and provide a Q11 DQ 0 mounting lip that takes the place of the integral mounting ring sup- U UU plied with the annunciators and expanders. tg 2.3 in 2.3 cm ca/ vQCs c7/ vc, ) !a RA-ENC1 (I �1 I_ 9.5 in I I� 24.1 cm 1 2.O in 9.8 in 5.1 cm 24.9 cm Dimensions(H x We Di IIm ) RA-ENC1 6.3 x 9.8 x 2.0 in(16.0 x 24.9 x 5.1 cm) RA-ENC2 12.0 x 9.8 x 2.0 in(30.5 x 24.9 x 5.1 cm) RA-ENC3 17.7 x 9.8 x 2.0 in(45.0 x 24.9 x 5.1 cm) RA-ENC3 Note:Allow approximately 2 inches(50 cm)clearance on both sides of the enclosure,to permit inserting and removing the key,and opening the door RA-ENC2 through 90 degrees. G Grr�� Page 3 of 4 DATA SHEET 85005- 1 €het to ho€kred f r Era tallation purposes. Issue 2 Specifications WARDS RLCD-C RLCD RLED-C RLED24 Operating voltage 24 VDC,continuous. Standby current 99 mA 98 mA 28 mA 6 mA Contact us... Alarm current 115 mA 113 mA 62 mA 34 mA Email: edwards.fire@fs.utc.com web: www.est-fire.com RS-485 communications Class A or Class B,9600 baud EST is an EDWARDS brand. Data wiring 18 to 14 AWG(1.0 to 2.5 sq mm)twisted pair(6 twists per foot minimum).Maximum wire run is 4,000 ft.(1,219 m) 1016 Corporate Park Drive Remote key switch circuit 5 VDC at 1 mA,power-limited,unsupervised Mebane,NC 27302 Ground fault impedance 0 In Canada,contact Chubb Edwards... Email: inquiries©chubbedwards.com Power wiring 18 to 14 AWG(1.0 to 2.5 sq.mm) Web: www.chubbedwards.com Display area 4 lines of 20 characters each ©2013 UTC Fire&Security Americas Dimensions(H x W x D) 5-5/8 x 8-1/2 x 1-1/2 in.(14.3 x 21.4 x 3.8 cm) Corporation,Inc.All rights reserved. Specifications subject to change Mounting North American 4-inch square electrical box or listed enclosure without notice.Edwards is part of UTC Agency Listing UL,ULC Climate,Controls&Security,a unit of United Technologies Corporation. Operating environment Temperature:32 to 120°F(0 to 49°C)Humidity:0 to 93%RH, noncondensing at 90°F(32°C) Ordering Information Part Description Remote Annunciators —y RLCD LCD text annunciator without common controls.English. RLCD-R LCD text annunciator without common controls.English.Red. RLCDF LCD text annunciator without common controls.French. RLCD-C LCD text annunciator with common controls.English. RLCD-CR LCD text annunciator with common controls.English.Red. RLCD-CF LCD text annunciator with common controls.French. RLED-C 16-pair LED zone annunciator with common controls.English. RLED-CR 16-pair LED zone annunciator with common controls.English.Red. BLED-CF 16-pair LED zone annunciator with common controls.French. Remote Expanders RLED24 24-pair LED zone expander with expander cable and zone card insert. RLED24R 24-pair LED zone expander with expander cable and zone card insert.Red. Enclosures RA-ENC1 One-position enclosure for Remote Annunciator. RA-ENC2 Two-position enclosure for Remote Annunciator and one Remote Expander, including one interconnection cable. RA-ENC3 Three-position enclosure for Remote Annunciator and two Remote Expanders, including two interconnection cables. LSRA-SB Surface Mount Box-for single R Series annunciator. Graphic Annunciator Drivers GCI Graphic Annunciator Driver,provides outputs for common indicators and 32 alarm/ supv zones as well as inputs for common switches.Provided with a snap track for mounting in custom graphic enclosures. Accessories RKEY Remote key switch on plate for enabling or disabling common controls(Lock/ Unlock). 27193-16 Electrical box,surface mount,white,single-gang,for RKEY. Page 4 of 4 > E r 85005-0128 t:a r:fl ft>r inst it ton pearposs. Issue2 w