Loading...
Specifications ME.C.21-(\01--03`3 \3 aZi-\ SS v , ` 1(A l\ - STRUCTURAL CALCULATIONS FOR TRIANGLE III STE 401 13221 SW 68TH PKWY TIGARD, OR -- FAN -- S.�RUCTupq< to PRO, dy w 2,187 ii At F.4..- .RECON 4 v ✓G<s- 15• N90^' o + tiN E. Noao�� ' I EXPIRES:12/31/20 I Contents Summary S1 Detail A D1 Calculations Cl -C5 Contact Person: John E Nordling,PE Enclosures El NORDLING Proj. No.: 19-037 TRIANGLE SUITE 401 ' STRUCTURAL DAMPER BOX ; ENGINEERS, LLC LATIMER HVAC 6775 SW 111th,Suite 200•Beaverton OR,97008 Date:FEB 2019 By:JEN Sheet No.: COVER SUMMARY 2014 Oregon Structural Specialty Code Seismic Occupancy Catagory II Site Class - D Seislmlc Design Catagory - ID Ss = 0.916 Si = 0.422 Sns = 0.122 Sol = 0.444 There is one new ceiling suspended variable air volume fan. TRANE 'VPEP0500P-5' weight 110 lbs length 45' width 36" height 15.5' . i 1 (4) 3/sto THREADED ROD SUPPORTS, SEE DETAIL ;` .-- —12ga SPLAY WIRE EACH SUPPORT POINT, EACH WAY NORDLING Proj. No.: 19-037 ‘,„ .:: 0 STRUCTURAL TRIANGLE SUITE 401 5 DAMPER BOX ENGINEERS, LLC LATIMER HVAC E: 6775 SW 111th,Suite 200'Beaverton OR,97008 Date:FEB 2019 By:JEN Sheet No.: S1 O-3/a"0 POWERS 'POWER-STUD+SDI' a--'3/8"4' DEWALT , (21/2" EMBED) EACH END "MINI-UNDERCUT+' (I' EMBED) WHERE SUPPORT ROD DOES NOT ....---(t (E) FLUTE `�~ ....---(tALIGN W/ (E)FLUTE, PROVIDE — , — UNISTRUT 'P000' I - NUT .-• (4) 344, THREADED ROD • • SUPPORTS, SEE DETAIL ...K.i . 12ga SPLAY WIRE EACH \ SUPPORT POINT, EACH -•' WAY / ' ` ` —DBL NUT is FAN { S1 U C T URq 4 st �0 PROF /D 1 87 c 111110 GREG so . OA FAN VU ' 'Oi�T t'oy� 15, ,s �\+� E. NOWT EXPIRES:12/31/20 ( NORDLING Proj. No.: 19-037 STRUCTURAL TRIANGLE SIM lb 401 ' DAMPER BOX 4, ‘ i4, ENGINEERS, LLC LATIMER HVAC 6775 SW 111th,Suite 200•Beaverton OR,97008 Date:FEB 2019 By: JEN Sheet No.:D1 ASCE 7.10 Standard I hoof ToplV�ch' 7nit Location 45°25'27.12"N Ss and SI=Mapped Spectral Acceleration Values 122°44'42.64"W 13221 SW 68th Pkwy,Tigard,OR 97223 Ground Motion Ss 0.976 Si 0.422 Occupancy Category II Site Coefficients Fa 1.1I Site Class D F., 1.58 Importance Factor 1.00 Height of Structure 30.0 ft SMs Fa* Ss 1.083 SMi Fv* Si 0.666 Design Category(SDC) D SDs (2/3)SMs 0.722 Sol (2/3)SMi 0.444 Air Side HVAC FP MIN= 0.3SDS IPWP ap 2.50 C RP 6.00 = 0.217 WP->*0 0.152 F 0.4.ap 'SDS •Ip �l+ W FP MAX= 1.6SDS IPWP P Rp l 2 G h�•YYp = 1.16 WP->* 0 0.809 z= 30.0 ft ASD FP= 0,36 WP->* 0.7 0.253 Eq= 0.152W+0.2 SDS W W :Weight of Unit z= 12.0 ft Fp= 0.22 WP->* 0.7 0.152 Height 15.5" Weight 110 lbs Length 45" Width 36" VEQ=0.152* 1101bs+0.2*0.722* 1101bs BRACE WITH: = 171bs+161bs 12ga SPLAY WIRE EACH SUPPORT POINT, EACH WAY T= 17 lbs *(16"/2)/36" + 161bs/2 - 0.6* 1101bs/2 _ -21 lbs [0 Net Uplift] V= 17 lbs NORDLING Proj. No.: 19-037 STRUCTURAL TRIANGLE SUITE 401 4. ko,......)467 DAMPER BOX ENGINEERS, LLC LATIMER HVAC 6775 SW 111th,Suite 200•Beaverton OR,97008 Date:FEB 2019 By:JEN Sheet No.: Cl 1 1 wa<v fowl Company name: ° 1;;;;;':',„,s Project: Date: 2/20/2019 F6 Version: 2,4.6290.27783 Project number: Page: 2/7 [ t i GEOMETRY: I 100 'i t if I I t 4 I I ! t ( t S Ry sir` :" i th r,2.....„ ,,,,,, ,0 LOAD ACTIONS:[Ib],[ft-Ib] j Z Design loads/actions Nu 100 lb NuY Vux 0 lb Vuy 20 lb �Muz / V MI.UX ux `s i MMuy - I uy "' • Muz - vux Mux t 3 3 input data and results must be checked for agreement with the existing circumstances,the standards and guidelines and must be checked for plausibility. PDA-Powers Design Assist® Anchors.pcp2 d a C2 t I. I a 'i No., s DE Ai8 ?oi`rers Company name: Project: Date: 2/20/2019 Version: 2.4.6290.27783 Project number: Page: 4/7 SUMMARY: - Selected anchor: DEWALT Mini-Undercut+ 3/8"0(UNC);hnom 3/4"(19mm),Grade 2 ° I Effective embedment: hey= 0.750 inch MORIIIIN Idbit Approval: ICC-ES ESR-3912 0 NI Basic principles of design: Design method: ACI 318-11 (Appendix D) Concrete: Normal weight concrete cracked concrete f'c =3000 psi Load combinations: from Section 9.2 Factored loads Anchor parameters: cmin = 2.50 inch smin = 2.75 inch hmin = 2.50 inch cac= 2.25 inch scr= 2.25 inch Anchor ductility: no Reinforcement: none edge reinforcement or<#4 bar Tension: Condition B Shear: Condition B Stand-off: not existent Seismic loads: no Resulting anchor forces/load distribution: Anchor No. Tension load Shear load #1 100 Ib 20 Ib Maximum 100 lb 20 lb Max.concrete compression strain: 0.00 °fin Max.concrete compression stress: 0 psi Resulting tension force: 100 lb Resulting compression force: 0 lb Calculations: Design proof: Demand Capacity Status Tension load 100 lb 199 lb 0.50<1.0 Shear load 20 lb 272 lb 0.07<_1.0 OK Interaction - - - - 0.48<_1.0 Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines and must be checked for plausibility. PDA-Powers Design Assist® Anchors.pcp2 C3 F • Company name: ' iiia as MEALY rowels Project: Date: 2/20/2019 Version: 2.4.6290.27783 Project number: Page: 5/7 DESIGN PROOF TENSION LOADING: Reference Steel strength: Nsa =4180 lb D.5.1 * Nsa = N * Nsa D.5.1.2 =0.65*4180 lb=2717 lb Nua =1001b Design proof: Nua/(a)* Nsa)= 100 lb/2717 lb= 0.04 5 1.00 Concrete breakout strength: hef =0.750 inch kc =17.0 Nb = kc *f.c0.5* An* hef1.5 D.5.2.2 = 17.0* 54.77* 1.00* 0.650= 605 lb ANcO =5.06 inch2 ANc =5.06 inch2 Wed,N =1.000 D.5.2.5 wc,N =1.00 D.5.2.6 Cac =2.25 inch Wcp,N =1.000 D.5.2.7 • * Ncb = * (ANc/ANcO) * Wed,N* 4ic,N * Wcp,N * Nb D.5.2.1 =0.40*(5.06/5.06)*1.000*1.00*1.000*605 lb =242 lb ( Nua =100 lb Design proof: Nua/((i)* Ncb)= 100 lb/242 lb= 0.41 5 1.00 A Pullout/Bond strength: Np,cr =455 lb D.5.3.2 <A * Npn = cp * (f'c/2500)A n * Np,cr = 0.40* (3000/2500)A 0.50 *455= 199 lb Nua =100 lb Design proof: Nua/(a)* Npn)= 100 lb/199 lb= 0.50 5 1.00 Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines and must be checked for plausibility. PDA-Powers Design Assist® Anchors.pcp2 C4 LEWaLT ?6,ve�5 CompanyProject: Date: 2/20/2019 Version: 2.4.6290.27783 Project number: Page: 6/7 DESIGN PROOF SHEAR LOADING: Reference Steel strength(without lever arm): Vsa =985 lb D.6.1 * Vsa = * Vsa D.6.1.2 =0.60*985 lb=591 lb Vua =20 lb Design proof: Vua/(c1)* Vsa)=20 lb/591 lb= 0.03 s 1.00 Pryout strength: hef =0.750 inch kc =17.0 Nb = kc*f' 05* Aa* hef1.5 D.5.2.2 = 17.0* 3000 0.5* 1.00* 0.750 1-5= 605 lb ANc =5,06 inch2 ANcO =5.06 inch2 1Ped,N =1.000 D.5.2.5 4icp,N =1.000 D.5.2.7 Wc,N =1.000 0.5.2.6 kcp =1.0 D.6.3.1 4:1 * Vcp = * (ANc/ANc0) * 4fed,N* 4icpN * tPc,N * Nb* kcp =0.45*(5.06/5.06)*1.000*1.000*1.000*605 lb*1.0 =272 lb Vua =20 lb Design proof: Vua/(l *Vcp) = 20 lb/272 lb= 0.07 S 1.00 COMBINATION TENSION/SHEAR LOAD: Reference Interaction: Design proof: = Nu/(0* Nn) + Vu/(0*Vn) /1.2 D.7.3 =(0.50+0.07)/1.2=0.4851.0 Fastening ok! Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines and must be checked for plausibility. PDA-Powers Design Assist® Anchors.pcp2 C5 Triangle 3 Suite 401 TI-Controls February 11,2019 t Unit Dimensions-Variable Air Volume Fan Powered Terminal Units item:Al Qty: 1 Unit size VPEF0502SQ - sN'N''hlI Nominal 5"Dia.x 6 5/8'Depth Valve Size 8 Depth Nominal '. Fan Size ::6:1: kz14"xTY 1) NOP' Equipment Schedule FPB4-XX-. Trane VPEF0500P-5"with parallel electric heat. 480/3/60-3KW. CO2 sensor and temp sensor. 150 CFM min, 450CFM max. 110#'ceiling suspended. i"*---2U" 4 1/2" 5" EMI OMu 16112" A AIRFLOW NOTES: O ch1.Allow a minimumct "plenum inlet clearance III �Vf for un-dued insta6llations. 1" 30" 2.Filter is secured in fifer frame located in unit inlet. H 3.For Motor access,remove bottom screws on 23 hanger brackets to slide panel as shown in drawing. 22" z 4.See Installation Documents for exact hanger co bracket location. 0 U 5.Air valve centered between top&bottom panel. HEATER 6" \!/ 6.Heating coil un-insulated. External insulation may PANEL SLIDES be field supplied and installed as required. FOR MOTOR ACCESS 7.All high&low voltage controls have same-side AIRFLOW NEC jumpback clearance. DISCHARGE OUTLET 8.Allow 48"of straight duct downstream of unit before first runout and inside of the duct should be equal discharge size. 9.Terminal box access door is side hinged.Allow for 5" —s- 40" clearance. 10.A4 wire power supply required for 48013&575\3 single point connection units. n 15112" 14" 151/2" ; 20„ >1 Approximate 110.0 lb Dry Weight Weights reflected may vary ±5.0 lb based upon options DISCHARGE VIEW selected. r El