Loading...
Report (16) . iNN-E:c.:-?sucA - o,..„ A CIiearr" ',') \c-\ \:\ ‘,./_0 ,------- -----.., OFFICE COPY CITY OF TIGARD United Technologies RECEIVED BUILDING D''IVISION JAN 2 2 2019 SUBMITTAL Project -Untitled1 Date Monday, January 7, 2019 P• 00-z, Table Of Contents Project: -Untitled1 01/07/2019 Prepared By: 09:35AM rtu1-2 3 Unit Report..._ 4 Certified Drawing 5 Performance Summary B Unit Feature Sheet 11 Spec Sheet 12 Packaged Rooftop Builder 1.49n Page 2 of 12 rtu1-2 Project: -Untitled1 01/07/2019 Prepared By: 09:35AM rtu 1-2 Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Spec Sheet Packaged Rooftop Builder 1.49n Page 3 of 12 Unit Report For rtu1-2 Project: -Untitled1 01/07/2019 Prepared By: 09:35AM Unit Parameters Dimensions(ft. in.)&Weight(lb.)*"* Unit Model. 48KCEA05A2A3-0A0A0 Unit Length. 6'2.375" Unit Size. 05(4 Tons) Unit Width. 3' 10.75" Volts-Phase-Hertz. 230-1-60 Unit Height 2'9.375" Heating Type. Gas —• Total Operating Weight 563 lb Duct Cfg. Vertical Supply/Vertical Return Medium Heat "' Weights and Dimensions are approximate. Weight does Single Stage Compressor Models not include unit packaging. Approximate dimensions are provided primarily for shipping purposes.For exact dimensions and weights,refer to appropriate product data catalog. Lines and Filters Return Air Filter Type. Throwaway Return Air Filter Quantity- 2 Return Air Filter Size. 16 x 25 x 2 Unit Configuration Medium Static Option Belt Drive Al/Cu-Al/Cu Base Electromechanical Controls Standard Packaging Warranty Information (Net Price Ea.) 1-Year parts(std.) $0 5-Year compressor parts(std.) $0 10-Year heat exchanger-Aluminized(std.) $0 No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity Master Price(ea.) 48KCEA05A2A3-0A0A0 Rooftop Unit 1 $11,695 Base Unit $11,563 Medium Static Option Belt Drive $132 None Packaged Rooftop Builder 1.49n Page 4 of 12 • Certified Drawing for rtu1-2 Project—Untitled1 01/07/2019 Prepared By: 09:35AM NOTES: ,yam UNITED v.R.mY 4x6 OT w IRS rluuIT Of MEER AtlMATIIA Nu 1.DIMENSIONS ARE IX INCHES DIMENSIONS ITECNNOLOVIES Ee2AA0.NI i SJ�[i; ,a Dye a7Hauru4R)u 0 r0tt [ u IX[ ]ARE IN MILLIMETERS. UNIT J N 11 PRASE/ X 13 PRASE) `CAAAIER wRrauT crt, .wI v cmAecr. 18NC 04 !8 /8 f/)/8 2. CENTER OF GRAVITY 18331311 id 1)111 [31)1 CONNECTION SIZES ''."OS 31 17 Id)/8 IB 5/e 3.I*DIRECTION OF AIRFLOW 18111 1;171 [1721 A 13/8'[351 DIA FIELD POWER SUPPLY HOLE 48NC O6 11 3!8 ''3-11? 18 5/8 0 2'1301 DIA POlER SUPPLY KNOCKOUT (1051] 3111 [1121 C 1 3/1'(511 0[A GAU6C ACCESS PLUG 38-0/8 D 1/8'(221 DIA FIELD CONTROL WIRING ROLE (8661 E 3/4'-14 NPT CONDENSATE DRAIN F I/2'-14 NPT 6AS CONNECTION • v G 2 1/2'(64]DIA POWER SUPPLY KNOCK-WT --.--32-I/4 v OOOA)WS (I81 16 , 4061 FIITEA ACCESS PANEL I TRU-THE-RASE OAST (TOOL-LESS) CgIP. THESE ROLES REWIRES FOR USE ACCf1S CONDENSER CRBTNPWROUTA01,003801 'PANEL I COIL ' - , .. . '1'. 4. ._ t I 'MENDED WINE REO'D HOLE INDOOR COIL � CONDUIT SIZE USE SIZES INA%.1 ACCESS PANEL I �^ y N 1/2' ACC. 7/8'62.21 i \ -'— 25-6!8 10-1/6 ♦ % 1/2' 2/8 7/8'[22.21 r [652] [211] _ "( RETURN AIR RETURN Y • 3/1'1001,0031 POWER 1 1/e'128.11 ypU1♦�I� C �_____ 44 • . 414 5*8 1000/1l2'FPS GAS I 3/16'130.01 (11117 JI O r FOR'O450-TME-BAEEPAX'FACTORY OPTION, BACK ANGLE 185/d FITTINGS FDR GILT N,Y,6 Z ARE PROVIDED TYPSELECT EITHER 3/4.ON 112' I CURB ^Y •DRAIN - 17-3/4 N FOR POWER,DEPENDING ON WIRE SIZE WIDTH 1 1651] i6 (0011 PROVIDES 3/4'FPI TRAY CURD IX BASEPAX SUPPLI 26-1/2 29-3/8FLANGE 3 FITTING. 18-1/e f ' /'Z AIR (6131 (Ili! :it 11 14361 J AIR 16-1/B /4-1/1 12-1/4 I [4111 [363] 1312] SEE 1NRU THE r1 (IOTA ilii BASE CHART t_. - ` (1511 4 r I 3-3/8 - — 12-1/8 1851 ". 3071 `—R [8381 -[100] T/0 D —18-1/2 14701 4-5/8 10-1/2 1-111 11181 [2651 (321 • IECTRICAL __ 1 i _ ' �OCWOFOWCT .i— 1 I CONDENSER I CONTROL BON INDOOR BLOWER COIL .�II ACCESS PANEL ACCESS [ y II CONDENSATE SLIER DRAIN OPTIONAL II ---• (681 FACTORY , 1� 19-1/2 16-3 1 IXST6lL ED OPTIOXAI - (1211 3N C CONVENIENCE _ --- [!91] FACTORY — �- AXOLE [1-3/8 i SUPPLY AIR 1 WIDE ���yyy11N I� OUTLET INSTALLED EIE [2891 DISCONNECT —.. ,0 , (5397 L fir______ iR 6-5/8 J BAY= =�B 11661 {O O 6-1/e _ j '�:- ooh 7,337 3-3/4 HANDLE g-SIB 6-518 i 6 [2131 (1681 [1711 1951 45-314 30-118 (1521 111811 [1617 26-118 )1-3/8 [1888] 16811 37-1/1 BAROMETRIC 17831 FLOWEF LEFT AIR Wik FRONT AIR RETURN RIGHT MET DATE WEIRDER 48KC 04-06 SINGLE ZONE ELECTRICAL REV 1 OF 09-16-14 - COOLING WITH GAS HEAT 000000281 _ Packaged Rooftop Builder 1.49n Page 5 of 12 Certified Drawing for rtu1-2 Project:-•Untitled1 01/07/2019 Prepared By: 09:35AM th 065180 P.0.NI rw 01R rn0K4n 01 urin mn04nlw s STD.UNIT CORNER CORNER CORIER CORNER TECNMOL041(3 t3m4N.II iar n[0 nsson asset 4 sum4101a mnan sa UNIT 67(641 1E1041 1.11 101641 18/ 660641 ICI 0(1441 101 C.6. 8E1447 fARR7ER uuarew s-,50 in. LOS. K6, LBS. K0. LBS. 66. LBS. 66. LBS. 66. K T Z 469C 04 490 222 120 54 111 30 123 56 135 61 35 3/4 19881 24 3/4 16281 16 1/6(4)91 441IC 05 544 246 130 54 126 51 142 61 146 66 36 3/4(9331 24 3/4 14261 14 1/8(4791 486C 06 591 270 141 64 156 10 158 11 142 64 39 1/4(9931 23 1/2 13971 26 t/8 15111 $011811"0114,19004 1448441 4901 611661 IS 4014 L06 645 NEAT RMD 11(4841 P4C0A61NG 606 OTHER 00110X$ANO 40003100081.REFER TO 1N(PKOOUCT 0414 CATALOG. CORNER A CORNER B • 111111!' \ CORNER 0 4 `..--' 'CORNER C TOP • JIi$I . ..X00 .ff=. 1=1: : Ooff FRONT SKIT NU 8158118966 48KC 04-06 SINGLE ZONE ELECTRICAL 48KC000281 Ery 2002 09-16-14 - COOLING WITH GAS HEAT — Packaged Rooftop Builder 1.49n Page 6 of 12 • Certified Drawing for rtu1-2 Project:-Untitledl 01/07/2019 Prepared By: 09:35AM Service Clearance D • • • 6 .21 • , PAM LOCATION DIMENSION CONDITION 48-in(1219 mm) •Unit disconnect is mounted on panel A 16-in(457 mm)) •No disconnect,convenience outlet option •Recommended terviceclearance 12-in(305 mm) •Minimum clearance 42-in(1067 mm) •Surface behind servicer is grounded(e.g.,meth,masonry waif) B 36-In(914 mm) •S nface behind servicer is electrically non-conductive(e.g.,wood,fiberglass) Special •Check for sources of flue products within 10-ft.of unit freshair intake hood C 36-in(914 mm) •Side condensate drain is used 18-in(457 mm) •Minimum clearance 48-in(1219 mm) •No flue discharge accessoryinstailed,surface is combustible material 42-in(1067 mm) •surface behind servicer Is grounded(e.g.,metal,masorvy wall,another unit) D 36-in(914 mm) •Indoor behind servicer is electrically non-conductive(e.g.,wood,fiberglass) Special •Check for adjacent units or budding fresh air intakes wthin 10-R.of this unit's flue outlet NOTE:Unit not designed to have overhead obstruction.Contact Appllcatlon Engineering for guidance on any application planning overhead obstruction or vertical clearances. Packaged Rooftop Builder 1.49n Page 7 of 12 Performance Summary For rtu1-2 Project: —Untitledl 01/07/2019 Prepared By: 09:35AM Part Number:48KCEAO5A2A3-0A0AO ARI SEER:.__ 14.00 Base Unit Dimensions Unit Length- 74.4 in Unit Width: 46.8 in Unit Height' 33.4 in Operating Weight Base Unit Weight' 544 lb Medium Heat' 9 lb Medium Static Option Belt Drive' 10 lb Total Operating Weight' 563 lb Unit Unit Voltage-Phase-Hertz' 230-1-60 Air Discharge' Vertical Fan Drive Type' Belt Actual Airflow' 1400 CFM Site Altitude' 39 ft Cooling Performance Condenser Entering Air DB' 90.0 F Evaporator Entering Air DB' 80.2 F Evaporator Entering Air WB' 64.9 F Entering Air Enthalpy 29.84 BTU/lb Evaporator Leaving Air DB' 55.6 F Evaporator Leaving Air WB' 53.5 F Evaporator Leaving Air Enthalpy 22.25 BTU/lb Gross Cooling Capacity' 47.75 MBH Gross Sensible Capacity' 37.19 MBH Compressor Power Input' 3.66 kW Coil Bypass Factor 0.134 Mixed Air Outdoor Air Airflow' 420 CFM Outdoor Air DB. 90.0 F Outdoor Air WB' 67.0 F Outdoor Air Htg.Temp' 22.0 F Return Air DB' 76.0 F Return Air WB' 64.0 F Return Air Htg. Temp' 70.0 F Heating Performance Heating Airflow: 1400 CFM Entering Air Temp' 55.6 F Leaving Air Temp* 104.3 F Gas Heating Input Capacity' 90.0 MBH Gas Heating Output Capacity- 0.0 173.5 MBH Temperature Rise' 48.7 F AFUE(%)` 81.2 Thermal Efficiency(%)' 82.0 Supply Fan External Static Pressure' 0.60 in wg Fan RPM- 1048 Fan Power 0.62 BHP NOTE' Selected IFM RPM Range: 770-1175 Electrical Data Packaged Rooftop Builder 1.49n Page 8 of 12 Performance Summary For rtu1-2 Project: -Untitled1 01/07/2019 Prepared By: 09:35AM Voltage Range- 187-253 Compressor#1 RLA. 21.8 Compressor#1 LRA. 117 Outdoor Fan Motor Qty. 1 Outdoor Fan FLA(ea). 1.5 Indoor Fan Motor Type. MED Indoor Fan Motor FLA. 4.9 Combustion Fan Motor FLA(ea). 0.48 Power Supply MCA. 34 Power Supply MOCP(Fuse or HACR). 50 Disconnect Size FLA. 32 Disconnect Size LRA. 133 Electrical Convenience Outlet None Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 85.0 86.1 90.9 125 Hz 78.5 75.6 84.6 250 Hz 69.2 61.5 79.5 500 Hz 65.5 60.4 77.9 1000 Hz 62.1 59.8 76.5 2000 Hz 56.5 53.8 71.1 4000 Hz 57.9 48.9 66.9 8000 Hz 52.5 41.0 62.5 A-Weighted 69.3 66.0 81.0 Advanced Acoustics .14l'4414 otk 11% Q Q► Advanced Accoustics Parameters 1. Unit height above ground. 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground. 5.7 ft 4. Height of obstruction. 0.0 ft 5. Horizontal distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction. 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 90.9 84.6 79.5 77.9 76.5 71.1 66.9 62.5 92.4 Lw Packaged Rooftop Builder 1.49n Page 9 of 12 Performance Summary For rtu1-2 Project: -Untitledl 01/07/2019 Prepared By: 09:35AM B 64.7 68.5 70.9 74.7 76.5 72.3 67.9 61.4 80.8 LwA C 58.5 52.2 47.1 45.5 44.1 38.7 34.5 30.1 60.0 Lp D 32.3 36.1 38.5 42.3 44.1 39.9 35.5 29.0 48.4 LpA Legend A Sound Power Levels at Units Acoustic Center, Lw B A-Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. �, FanCurve 20 _ 1*RPM 15Q0RPAA 1700RPM 2100RPM 193CRPM -1100RPM 15 c \ \ 2 7 co 10 - O3 _700FPM C/3 ,5AOBFip\ 05 -500RPM 3. \zol:• 1:1: 4 .93BHP 3WRPM CO ( I I I I 11 I I I\ I \ I \ I I I I I I I I I CO 05 10 15 20 25 30 35 40 Alrflow(CFM-thousands) RPM=1048BHP=0.62 Maximum RPM=2100Maximum BH P=2.90 Note:Pleasecontactapplicationengineeringforselectionsoutsidetheshadedregion. SC-SystemCu ve RP-RatedPoint Packaged Rooftop Builder 1.49n Page 10 of 12 Unit Feature Sheet for rtu1-2 Project: -Untitled1 01/07/2019 Prepared By: 09:35AM arrie�r (; WeatherMaker — 48KC PACKAGED ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS-14 SEER 3,4,5 TONS STANDARD FEATURES INCLUDE: 5',,- _ • Puron(R-410A)HFC refrigerant ' r •Meets and exceeds ASHRAE90.Ienergy efficiency levets ,t• `_ --3' • Scxok compressors with internal fine break and overload protection t - • Single-stage cooling capacity control ��a.�� � � SEER'supto14A,EERSupto12.0 r„.,`, •Acutrol' refrigerant metering system ,.,�. , �'" • Exclusive non-corrosive composite condensate pan in accordance with a 41 g7-ri_ ASHRAE Standard 62,sloping design,side orcenterdrain `'' "..i.,:".* ',. - „ - • Standard cooling operation up to115'F(46'C)and down to40'F(4'C) . -" . ..... ,orr - down to 25'F(4kit 'C)with winter start . • Pre-painted exteriorpanels and primer-coated interiorpanelstested to 500 hours salt spray protection • Futy insulated cabinet • Exclusive IGC solid-state controlfor on-board diagnostics with LED error code designation burner control logic and energy saving indoor MRA fanmotordeiay Puron • fawn moordelamodels that meet California AiQualityManagement ' • Induced draft gas heat combustion design COMPLIANT • Redundant gas valves with up to two stages of heating • Low pressure end high pressure switch protected. MAINTENANCE FEATURES: •Access panels with easy grip handles • Innovative easy starting,no-strip screws on unit access panels •Two-inch disposable return air£iters and Tool-less filter access door WEATHERMAKER SERIES • Direct Drive-ECM indoor motor is standard with optional belt drive systems WeatherMaker 48KC (14-SEER) units are one-piece gas •Terminal board fac tating sirripte safetycircittroubleshootingand heating, electric cooling units that are pre-wired and charged si pkfied control box arrangement with Puron(R-410)refrigerant. They are factory tested in both •Exclusive IGC solid-state control for on-board diagnostics with LED heating and cooling modes,and rated in accordancewith AHRI error code desig nation,bumercontrol log icand energy saving indoor Standards 210/240. WeatherMaker units are designed in fan motor delay. accordance with UL Standard 1995, and listed by the INSTALLATION FEATURES: Underwriters'Laboratories. •Thnr-the-bottompcwerentry cap abity • Single point gas and electric connections Approved and certified • Full perimeter base rail with buit-i n rigging adapters and fork slots by: Reid convertible from vertical to honzontalaiflow t STANDARD WARRANTY: .+. CERTIFIED- ....... • 10-year heat exchanger-15-yearsteiniess steel option Vie d•.,Vk•car••A • 5-yearcompressar C US ruw.0100000.1. • 1-yearpaits :„ � • h4anyoptronaiupgradesasaavailatile :!, .,,r.sv Pn ww:aro OPTIONS INCLUDE BUT ARE NOT LIMITED TO: • PrerxierLink and RTU Open Multi Protocol DDC Controls • Supply and Return AS Smoke Detectors,high static motors • Louvered condensercoiguerds • Disconnect switch and convenience outlet options • Ste inlessSteeiheat exchanger option • Corrosion resistant oak coating. Certified to ISO 9001 • l-figh staticmotor options • Patentedfb.nnidi-tvkZer•adaptivedehunidificationsystem.Thsoption also includes Motormaster I controls • Hinged access panels • Integrated economizer system.Standard end Ultra Low Leak versions Fora co rreplete list of options a nd accesso ries refe rto the Product Data Catalog forthis unit. Packaged Rooftop Builder 1.49n Page 11 of 12 Spec Sheet for rtu1-2 Project: -Untitled1 01/07/2019 Prepared By: 09:35AM Packaged Rooftop Builder 1.49n Page 12 of 12 NOTES: VENTILATION AIR SCHEDULE AIR DISTRIBUTION DETAILS 1.CEILING DIFFUSERS TO BE SHOEMAKER HVD SERIES pe,mer 'vv. ...APP.* .m. �• F } { WITH OBD,RETURN AIR GRILLES TO BE 600-0 SERIES w.a..wvw,m w mw ^p°o^ <^, ,,r aa.rv.n w' rvm r.„+ °Y1"°.. ,� " 1, EMU ws f^^I ^^... 2.ALL SUPPLY AND RETURN AIR DUCTWORK TO BE 7-(417" REg.2a `1'�L3 � GALVANIZED METAL WITH WRAPPED INSULATION. se TILT FLEX DUCT TO BE USED IN CONCEALED AREAS. ""'+"'�"°' °r '° if • r '+• ^ .w ^"" ,w —gas w.w ..XL,. m._ '7 °' 3.ALL SUPPLY AND RETURN AIR DUCTWORK TO BE 1 l la ....m+m r w. w. w. w. w. w. w. ..m .�.. ,. ....war, - INSULATED WITH 1..1.58S SA.DIMENSIONS SHOWN u..w.+w ,r + I _ ARE NET INSIDE. ° a. • 'O • +i ' +m Ii 4.FLEXIBLE DUCTWORK TO BE PREFORMED FIBREGLASS ....PA ,r ...c . , • -• • a ., 5.1,-, .w -+* SPIRAL WOUND,WIRE REINFORCED WITH VAPOR .....o.m a : a q v j I• MVO :n m °Z'-° ...."• BARRIER,FIBRE SCRIM CLOTH INTERIOR LINING, 1) o^,.. a �Y,. w� •-••• UL LISTED-THERMOFLEX OR EQUAL. M .065.INSTALL VOLUME DAMPERS ON ALL TAKEOFFS. ArDRAANo8.GAS PIPING TO BE 2 PSI WITH PRESSURE REGULATORS AT EACH r ,r • r . a ,. ...v. +r I:::::=. I =7- EQUIPMENT CONNECTION.3CH 48 BLACK IRON PIPE " """' 'w .• -- y_-_� ^ ------ T.COMPLETE INSTALLATION TO COMPLY WITH 2019 OMSC AND M O �`•r•`•"°a+'.'° w. e. P• '• m T. a. -.w y -�- �m'F `=- ALL LOCAL MECHANICAL CODES. M - L 8.ALL NEW GAS PIPING TO BE INSTALLED PER THE 2014 05150 SII~.. -• --- FUELGAS CODE APPENDIX 0402,4(5)AND SECTIONS THAT APPLY. A Lw _ DUH x II II a EXISTING ELEC. PANEL / ., SOL 'I}-Al1a'° - .._— T __1—I -1_ if. A���O «NE He...o®e g... ... .... „wm eoal.wm ,,. «.c..va.� JLL MARA N/A N/A MS 4wwAM4w4rao �P1a, ZzE_iiJifAiI'IfliIII$i r 38., R0021 MM 1 ,mo.m 1m aa- F +m,+ N+A wA re,x = 1LI'IIrIjIiIu;gi'! 22ENS TO D ON iod re X�i�If •.0 ���� �, N `! 11 (Q�111.1 II cft y tyI : Iii I NOTES: w a— Fr i ari 1.TOTAL GAS CU FTMR INPUT 160 MBH y rf2 TOTAL EQUIVALENT LENGTH(TDL)100 FT ` .yII 9.2 PSI GAS SERVICE ILRAFa a BHC• 1.11Y• �• 9.GAS PIPE TO BE SCH 40 BLACK IRON PIPEAL MIII 0 OOIR '�' f�I5.GA3 REGULATORS REQUIRED ON ALLTOTAL (I 1, O ' ' MECHANICAL HOOF UNILENOTM�To�)E0 ,TO111 s��� �11 �� 8.GA9 PIPING SIZED BASED ON 2019 GMSCF Q = _ .I APPENDU(C 402.x(5)SCH 90 BLK PIPE 1,1 pIII xaa Iziw A ui w.,=1=I-1eIgwnF MECHANICAL PLAN m•u'. " DATA 1219/2013 1)4".1'.0' ORAWN BY EEL =N41E:241 F.O GW-Z OTEO REVISIONS c•,,,,,.....3,•,•••,..Mw M"1 F 2018-5