Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
RECEIVED 1C ' COPY FEB 2 7 2019 P POTTERCITY OF TIGARD PFC-441 SRC The Symbol of Protection BUILDING DIVISION RELEASING CONTROL PANEL •Multi-Hazard Operation •Four Class B Initiating Circuits •Two Class B Supervisory Circuits** •Four Class B Output Circuits •Programmable Cross Zoning •Supervised Microprocessor t •32 Character Alpha-Numeric LCD Display •Custom Banner Message and Zone Description text •Custom Zone Description Text I • •On Board Menu Driven Programming Controls •Releasing Circuits Protected From False Activation •Continuous or Timed Discharge •40 Event History Buffer •Walktest with Automatic Time-out •Alarm,Trouble Supervisory,and Waterflow relays PFC Series •Optional Class A Initiating Zone and output module " Reieag;,,9 Pdfe' •34 character LED supplemental display •24 Standard Programs in Panel Memory •Password Protection for all Programming •24 Hour Clock •Suitable for agent or water-based extinguishing •Programmable pre-discharge timers* • •One Class B Abort circuit*(Defaults to additional supervisory zone in water based mode.) Dimensions: 18'/4"x 14'/2"x 4 3/4" •Four Abort modes* UL and ULC Listed,FM Approved,NYMEA Accepted,CSFM *Available in Chemical mode only Approved,CE Marked,and RoHS Compliant. **One zone programmable as abort in chemical mode. General Description The Potter Model PFC-4410RCisaflexiblemulti-hazard releasing control The panel is Ninth Edition UL listed, ULC listed, Factory Mutual, panel that is well suited for a number of applications.The PFC-441 ORC California State Fire Marshal(CSFM),New York Materials Equipment is listed for use with pre-action and deluge sprinkler suppression systems Acceptance(MEA)Approved,CE Marked,and RoHS Compliant. and agent based fire suppression systems. The PFC-4410RC is housed in a durable steel cabinet with removable The panel utilizes a microprocessor-based system that has 24 Standard door and key lock.The panel is available in either a red or white finish Programs,which covers a majority of installations.The simple to follow and an optional flush mount trim ring is available.The cabinet contains Menu Structure programs the entire system in a matter of minutes.In knockouts on the side,back and top of the cabinet to ease installation. addition to the Standard Programs,the panel allows custom programming In addition,the cabinet will house up to 18 amp-hour batteries that will to accommodate any installation. provide in excess of 90 hours of standby power. Ordering Information Model Number Description Stock Number PFC-4410RC 4 Zone Releasing Control(White Cabinet) 3006144 PFC-4410RC 4 Zone Releasing Control(Red Cabinet) 3006142 PFC-4410RC-PCA Replacement Motherboard 3006230 PFC-TW Bezel for Semi-Flush Mounting(White) 5090157 PFC-TR Bezel for Semi-Flush Mounting(Red) 5090155 BT-80 Battery, 12V 8AH for 24 hour standby(2 Req'd) 5130084 BT-120 Battery, 12V 12AH for 24 hour standby(2 Req'd) 5130090 BT-180 Battery, 12V, 18AH for 90 hour standby(2 Req'd) 5130086 CA2Z 2 Zone Class A Initiating Circuit Module 3006013 CAM Class A Indicating Circuit Module 3005300 ARM-44 Relay Module for PFC-4410RC 3006221 ARM-2 Auxiliary Relay Module 3004725 RA-4410RC Remote Annunciator 3006400 BB-RA-44R Surface Mount Back Box for RA-4410RC(Red) 3006401 Potter Electric Signal Co.,LLC•St.Louis,MO•Cust Service:866-240-1870•Tech Support:866-956-1211•Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MFG#5401250-REV C PAGE 1 OF 2 3/14 P POTTER PFC-4410RC The Symbol of Protection RELEASING CONTROL PANEL Architects/Engineers Specifications The control panel for the extinguishing agent releasing system shall Waterflow,Linear Heat Detection(up to 700 ohms per zone),Manual be a microprocessor based control capable of protecting multiple Release,Low Air Alarm,Supervisory,Tamper,Low Air or High Air. hazards in one control panel.It shall be Underwriters Laboratories Optional Class A modules,CA2Z,may be added for Class A Inc.listed under Standard 864 Ninth Edition and Underwriters operation. Laboratories of Canada for Local Control Units for Releasing Service. The control shall also be approved by Factory Mutual Research The panel shall have a Low Air Zone that creates a supervisory Corporation and be compliant with the requirements of NFPA-72 condition and can be mapped to a release output. (Local:A,M,SS service types;DAC and NC signaling type)and The control shall have two fully supervised Class B(Style B) NFPA12,NFPA12A,NFPA-13,NFPA-15,NFPA-16,NFPA-17, supervisory circuits.These circuits shall be selectable through the NFPA-17A,NFPA-750,and NFPA-2001. programming sequence to operate in one of the following modes: The control shall be housed in an 18 gauge steel cabinet that has a Supervisory,Tamper,Low Air or High Air. hinged,removable door with a key lock.The finish shall be baked The control shall have one fully supervised class B(style B)Abort enamel and available in red or off-white with contrasting trim and circuit with 4 different operating modes,ULI,IRI,and NYC,and 30 logo.An optional matching bezel should be available for semi-flush second. mounting.The cabinet shall have adequate space to house 18 AH standby batteries capable of operating the system for at least 90 hours. The control shall have four fully supervised Class B(Style Y)output circuits.These circuits shall be selectable through the programming The control shall include a fully supervised integral power sequence to operate as one of the following:Alarm Notification supply/battery charger capable of providing 200mA to the auxiliary Appliance,Supervisory Notification Appliance,Trouble Notification power circuit.It shall also be capable of providing 2.5 Amps to all Appliance or Releasing. The optional CAM module may be added to releasing and notification appliance circuits combined.All initiating, convert the outputs to Class A. output and auxiliary power circuits shall be power limited. The panel shall have an RS-485 output and auxiliary power outputs The control shall have a 32 character(16 characters,2 lines)backlit for connection and supervision of up to 4 remote annunciators or an LCD display and a 34 LED supplemental display.All diagnostic and ARM-44 Relay Module and 3 annunciators. alarm event information shall be viewable in text form on this display. A field programmable custom banner message with the current date The releasing circuits shall be supervised for short circuit conditions and shall be programmable for cross zoning operation when required. and time shall be displayed when no current alarm or diagnostic information exists. The discharge timer for these releasing circuits shall be programmable for times of 7,8,9, 10,20 minutes or continuous.All initiating and All operational features of the control panel shall be field output circuits shall be capable of being individually disabled or programmable using menu driven selections on the alpha-numeric enabled.In addition,when in the agent extinguishing mode there shall display and on board controls.No special programmer will be be a pre-discharge timer adjustable from 0-60 seconds from an alarm required and jumpers or switches to configure operational features zone or 0-30 seconds from a manual release zone. shall not be permitted.Alarm and trouble indications shall resound when required. The control shall have a test mode that will automatically disable all releasing circuits.The test mode shall operate in such a manner The control panel shall be equipped with 24 programs built into the as to automatically reset the initiating circuit and indicating circuits panel memory,15 for water based extinguishing and 9 for agent after detecting each alarm condition initiated by the test.All testing extinguishing.In addition,the panel shall have the ability to add custom shall be recorded in the 40 event history buffer.The test mode will programs.All programming functions shall be password protected. automatically terminate after twenty minutes of inactivity. The control shall have four fully supervised Class B(Style B) The control shall have four integral relay contacts rated 3 Amps at 30 initiating circuits capable of supporting the operation of 25 compatible VDC for connection to external auxiliary equipment.One relay shall 2-wire smoke detectors on each circuit. operate when an alarm condition occurs,another when a trouble signal The individual circuits shall be selectable through the programming occurs,the third when a supervisory condition occurs,and the fourth sequence to operate in one of the following modes:Conventional, during a waterflow condition. UL and ULC Listed,FM Approved,NYMEA Accepted,CSFM Approved, CE Marked and RoHS Compliant. PRINTED IN USA MFG#5401250-REV C PAGE 2 OF 2 3/14 Monitor Modules °"6999:0 NMM-100(A), NMM-100P(A), ® N oT I F I E R° NZM-100(A), and NDM-100(A) for FireWarden Series Panels by Honeywell Intelligent Addressable Devices General Four different monitor modules are available for Notifier's Fire- Warden Series intelligent control panels for a variety of appli- cations. Monitor modules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull - - stations, or monitor and power a circuit of two-wire smoke """ t.? detectors(NZM-100(A)). 1/1411,41J11•LAIR ROOM MATEY, NMM-100(A)is a standard-sized module(typically mounts to a � •°,.)n 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry contact input • devices. NMM-100P(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D that supervises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the NMM-100P(A) to be mounted in a single-gang box behind the device it monitors. i► NZM-100(A) is a standard-sized module that monitors and -� 4011 supervises compatible two-wire,24 volt,smoke detectors on a Style D(Class A) or Style B(Class B)circuit. NDM-100(A) is a standard-sized dual monitor module that NMM-100(A)(Type H) monitors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate,consecutive addresses in intelligent,two-wire systems. NMM-100(A) OPERATION Each NMM-100(A) uses one of the available module NMM-100(A) Monitor Module addresses on an SLC loop. It responds to regular polls from • Built-in type identification automatically identifies this device the control panel and reports its type and the status(open/nor- as a monitor module to the control panel, mal/short)of its Initiating Device Circuit(IDC). A flashing LED indicates that the module is in communication with the control • Powered directly by two-wire SLC loop. No additional power panel. The LED latches steady on alarm (subject to current required. limitations on the loop). • High noise(EMF/RFI)immunity. • SEMS screws with clamping plates for ease of wiring. NMM-100(A) SPECIFICATIONS • Direct Decade entry of address: 01 — 99 on FireWarden- Nominal operating voltage: 15 to 32 VDC. 100-2,01 —50 on FireWarden-50. Maximum current draw:5.0 mA(LED on). • LED flashes during normal operation and latches on steady Average operating current: 350 pA (LED flashing), 1 corn- to indicate alarm. munication every 5 seconds,47k EOL. The NMM-100(A) Monitor Module is intended for use in intelli- Maximum IDC wiring resistance:40 ohms. gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro EOL resistance:47K ohms. vides either a two-wire or four-wire fault-tolerant Initiating Temperature range:32°F to 120°F(0°C to 49°C). Device Circuit (IDC) for normally-open-contact fire alarm and Humidity range: 10%to 93%noncondensing. supervisory devices. The module has a panel-controlled LED indicator. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x NMM-100(A)APPLICATIONS 2.125"(5.398 cm)deep box. Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B(Class B)or Style D (Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. DN-6999:C•10/06/2010—Page 1 of 4 NMM-100P(A) Mini Monitor Module Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65"(1.651 cm)deep. • Built-in type identification automatically identifies this device as a monitor module to the panel. Wire length:6"(15.24 cm)minimum. • Powered directly by two-wire SLC loop. No additional power required. NZM-100(A) Interface Module • High noise(EMF/RFI)immunity. • Supports compatible two-wire smoke detectors. • Tinned,stripped leads for ease of wiring. • Supervises IDC wiring and connection of external power • Direct Decade entry of address: 01 — 99 on FireWarden- source. 100-2,01 —50 on FireWarden-50. • High noise(EMF/RFI)immunity. • SEMS screws with clamping plates for ease of wiring. 1415 01 ADDRESS 0 1 • Direct Decade entry of address:, 01 — 99 on FireWarden- 13 2 2 100-2,01 –50 on FireWarden-50. �� 8_7 4 LOOP 043 4 • LED flashes during normal operation. 10 5 5 • LED latches steady to indicate alarm on command from 9 6 96 control panel. 8 7 8 7 TENS ONES The NZM-100(A)Interface Module is intended for use in intelli- n gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status(nor- 0W mal,open,or alarm)of one full zone of conventional detectors W U back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. NZM-100(A) APPLICATIONS Use the NZM-100(A) to monitor a zone of two-wire smoke 7 ( L detectors. The monitored circuit may be wired as an NFPA Style B(Class B)or Style D(Class A) Initiating Device Circuit. The NMM-100P(A) Mini Monitor Module can be installed in a A 3.9 K ohm End-of-Line Resistor (provided) terminates the single-gang junction directly behind the monitored unit. Its end of the Style B or D (class B or A) circuit (maximum IDC small size and light weight allow it to be installed without rigid loop resistance is 25 ohms). Install ELR across terminals 8 mounting. The NMM-100P(A) is intended for use in intelligent, and 9 for Style D application. two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- NZM-100(A)OPERATION ing device circuit for normally-open-contact fire alarm and Each NZM-100(A) uses one of the available module security devices. NMM-100P(A) addresses on an SLC loop. It responds to regular polls from NMM 100P(A)APPLICATIONS the control panel and reports its type and the status(open/nor- mal/short)of its Initiating Device Circuit(IDC). A flashing LED Use to monitor a single device or a zone of four-wire smoke indicates that the module is in communication with the control detectors,manual fire alarm pull stations,waterflow devices,or panel. The LED latches steady on alarm (subject to current other normally-open dry-contact devices. May also be used to limitations on the loop). monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device NZM-100(A)SPECIFICATIONS is wired as an NFPA Style B(Class B)Initiating Device Circuit. Nominal operating voltage: 15 to 32 VDC. A 47K ohm End-of-Line Resistor(provided)terminates the cir- cuit. Maximum current draw:5.1 mA(LED on). Maximum IDC wiring resistance:25 ohms. NMM-100P(A)OPERATION Each NMM-100P(A) uses one of the available module Average operating current: 300 pA, 1 communication and 1 LED flash every 5 seconds,3.9k eol. addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status(open/nor- EOL resistance:3.9K ohms. mal/short)of its Initiating Device Circuit(IDC). External supply voltage (between Terminals T3 and T4): NMM-100P(A) SPECIFICATIONS DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum.Current: 90 mA per module maximum. Nominal operating voltage: 15 to 32 VDC. Temperature range:32°F to 120°F(0°C to 49°C). Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Humidity range: 10%to 93%noncondensing. Shorted). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Maximum IDC wiring resistance:40 ohms. 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125"(5.398 cm)deep box. Maximum IDC Voltage: 11 Volts. Maximum IDC Current:400 pA. EOL resistance:47K ohms. Temperature range:32°F to 120°F(0°C to 49°C). Humidity range: 10%to 93%noncondensing. Page 2 of 4—DN-6999:C•10/06/2010 NDM-100(A) Dual Monitor Module • MEA: 72-01-E Vol. 2 (NMM-100, NMM-100P, NZM-100); 227-03-E Vol.3(NDM-100) The NDM-100(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two Product Line Information wire initiating device circuits(IDCs)at two separate,consecutive addresses. It is capable of monitoring normally open contact fire NOTE:A"suffix indicates ULC-listed model. alarm and supervisory devices.The module has a single panel NMM-100(A): Monitor module. controlled LED. NOTE: The NDM-100(A)provides two Style B(Class B) IDC cir- NMM-100P(A): Monitor module, miniature. cults ONLY. Style D(Class A)IDC circuits are NOT supported in NZM-100(A): Monitor module,two-wire detectors. any application. NDM-100(A): Monitor module, dual, two independent Class B NDM-100(A)SPECIFICATIONS circuits. Normal operating voltage range: 15 to 32 VDC. SMB500:Optional surface-mount backbox. Maximum current draw:6.4 mA(LED on). NOTE: See installation instructions and refer to the SLC Wiring Average operating current:750 pA(LED flashing). Manual,PN 52304. Maximum IDC wiring resistance: 1,500 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current:240 pA EOL resistance:47K ohms. Maximum SLC Wiring resistance:40 Ohms. Temperature range:32°to 120°F(0°to 49°C). Humidity range: 10%to 93%(non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125"(5.398 cm)deep. NDM-100(A) AUTOMATIC ADDRESSING The NDM-100(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the NDM-100(A) is set to address "26", then it will automati- cally assign itself to addresses"26"and"27". NOTE: "Ones"addresses on the NDM-100(A)are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address,and terminals 8 and 9 use the second address. QCAUTION: Avoid duplicating addresses on the system. Installation NMM-100(A), NZM-100(A), and NDM-100(A) modules mount directly to a standard 4" (10.16 cm)square,2.125"(5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes,ordinances,and regu- lations. These modules are intended for power-limited wiring only. The NMM-100P(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordi- nances,and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL:S635 • ULC:S635 • FM Approved • CSFM: 7300-0028:0230 (NMM-100, NMM-100P, NZM- 100);7300-0028:0237(NDM-100) DN-6999:C•10/06/2010—Page 3 of 4 Notifier®and FireWarden®are registered trademarks and FireWatchTm is a trademark of Honeywell International Inc. ©2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. CERTF I E We cannot cover all specific applications or anticipate all requirements. ENGINEERING S MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-6999:C•10/06/2010 dn-60383:A2 NC-100R(A) NOTIFIER® Relay Module for FireWarden Series Panels by Honeywell Addressable General The NC-100R(A) Addressable Relay Module provides NOTI- FIER's FireWarden Series intelligent control panels with two isolated sets of Form-C dry-contact outputs for activating a variety of auxiliary devices, such as fans, dampers, door hold- ers, control equipment, etc.Addressability allows the dry con- tact on tact to be activated, either manually or through panel programming,on a select basis. .y CWMt 5C t1tt Features •ci am,.a.r+ws *4" • Built-in type identification automatically identifies these *I4. • devices to the control panel. • Internal circuitry and relay powered directly by two-wire SLC loop. "1r4, • • Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady when • • activated. 11110 41) • High noise immunity(EMF/RFI). o • Wide viewing angle of LED. • SEMS screws with clamping plates for wiring ease. NC-100R(A) • Direct Decade entry of address: 01 —99 with the FireWar- den-100-2(C)and 01 —50 with the FireWarden-50(C). Applications The NC-100R(A)may be programmed to operate dry contacts Specifications for door holders,Air Handling Unit shutdown,etc.,and to reset Normal operating voltage: 15 to 32 VDC. four-wire smoke detector power. Maximum SLC current draw: 6.5 mA(LED). Construction Average operating current: 230 pA direct poll (CLIP mode), • The face plate is made of off-white heat-resistant plastic. 255 NA group pot with LED flashing. • Controls include two rotary switches for direct-dial entry of EOL resistance: not used. address setting. Temperature range: 32°F to 120°F(0°C to 49°C). • The NC-100R(A) provides two Form-C dry contacts that Humidity range: 10%to 93%non-condensing. switch together. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Operation 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125"(5.398 mm)deep box. Each NC-100R(A)uses one of the addresses on a SLC loop. It responds to regular polls from the control panel and reports its Relay Contact Ratings type and status. The LED blinks with each poll received. On command, it activates its internal relay. Maximum Current Load Description Application Rating switches set a unique address for each module. TheVoltage address may be set before or after mounting. The built-in Resistive Non-Coded 30 VDC 3.0 A TYPE CODE(not settable)will identify the module to the con- trol panel. Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive(L/R=5ms) Coded 30 VDC 0.5 A Inductive(L/R=2ms) Coded 30 VDC 1.0 A Inductive(PF=0.35) Non-Coded 125 VAC 0.5 A dn-60383:A2•06/17/10—Page 1 of 2 Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UUULC Listed:S635. • CSFM approved:file 7300-0028:230. • FM approved. • MEA approved:file 72-01-E,Vol.2. Product Line Information NC-100R: Intelligent addressable relay module. NC-100RA: Intelligent addressable relay module, ULC listed model. SMB500:Optional surface-mount backbox. NOTE: For installation instructions, see document 156-2593-001 and refer to the SLC Wiring Manual,document 52304. NOTIFIER®is a registered trademark of Honeywell International Inc. ©2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO ���� This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. CERT 1 F•E D We cannot cover all specific applications or anticipate all requirements. ENUINEMINLBMANUFACT1IING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—dn-60383:A2•06/17/10 SYSTEM �.$ SENSOR® 1.4 ti Photoelectric Smoke Detectors System Sensor i3" series smoke detectors represent • significant advancement in conventional detection. 3 The i3 family is founded on three principles:installation ease,intelligence,and instant inspection. Features Installation ease.The i3 line redefines installation ease with its •Plug-in detector line,mounting base included plug-in design.This allows an installer to pre-wire bases(included with heads).The large wire entry port and in-line terminals provide •Large wire entry port ample room for neatly routing the wiring inside the base.The base •In-line terminals with SEMS screws accommodates a variety of back box mounting methods as well as •Mounts to octagonal and single-gang back boxes,4-square back direct mounting with drywall anchors To complete the installation,i3 boxes,or direct to ceiling heads plug into the base with a simple Stop-Drop'N Lock'"action. •Stop-Drop'N Lock attachment to base Intelligence.i3 detectors offer a number of intelligent features •Removable detector cover and chamber to simplify testing and maintenance.Drift compensation and •Built-in remote maintenance signaling smoothing algorithms are standard with the i3 line to minimize nuisance alarms.2-wire i3 detectors can generate a remote LED- •Drift compensation and smoothing algorithms indicated maintenance signal when connected to the 2W-MOD2 •Simplified sensitivity measurement loop test/maintenance module or a panel equipped with the i3 •Wide angle,dual color LED indication protocol.The SENS-RDR,a wireless device,displays the sensitivityof i3 • detectors in terms of percent-per-foot obscuration. •Loop testing via EZ Walk feature •Built-in test switch Instant inspection.The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition:normal standby,out-of-sensitivity,alarm,or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the P protocol,the EZ Walk loop test feature is available on 2-wire i3 detectors.This feature verifies the initiating loop wiring by providing LED status indication at each detector. Agency Listings 14) ® (W MEA MSFM LISTED APPROVED ilia' approved approved c us 5911 3011446 7272-1653:152 290-01< (j. Smoke Detector Specifications Architectural/Engineering Specifications Smoke detector shall be a System Sensor i3 Series model number ,listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type(Model 2W-B,4W-B)or a combination photoelectric/thermal(Model 2WT-B,4WT-B)with thermal sensor rated at 135°F (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal,single-gang,and 4-inch square back boxes with a plaster ring,or direct mount to the ceiling using drywall anchors.Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- color LED indication that blinks to indicate power up,normal standby,out of sensitivity,alarm,and freeze trouble(Model 2WT-B,4WT-B)conditions.When used in conjunction with the 2W-MOD2 module,2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24V non-polarized Minimum: 8.5 V Maximum: 35 V Maximum Ripple Voltage 30%peak to peak of applied voltage Standby Current 2-wire:50 NA maximum average;4-wire:50 pA maximum average Maximum Alarm Current 2-wire:130 mA limited by control panel;4-wire:20 mA @12 V,23 mA @ 24 V Peak Standby Current 2-wire:100 pA;4-wire:n/a Alarm Contact Ratings 2-wire:n/a;4-wire:0.5 A @ 30 V AC/DC Physical Specifications Dimensions(including base) 5.3 inches(127 mm)diameter;2.0 inches(51 mm)height Weight 6.3 oz(178 g) Operating Temperature Range 2W-B and 4W-B:32°F to 120°F(0°C to 49°C);2WT-B and 4WT-B:32°F to 100°F(0°C to 37.8°C) Operating Humidity Range 0 to 95%RH non-condensing Thermal Sensor 135°F(57.2°C)fixed Freeze Trouble 2VVT-B and 4WT-B only:41°F(5°C) Sensitivity 2.5%/ft nominal Input Terminals 14 to 22 AWG Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Modes Power-Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal(standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal Wiring` Alarm Current 2W-B No 2-wire 130 mA max.limited by control panel 2WT-B Yes 2-wire 130 mA max.limited by control panel 4W-B No 4-wire 20 mA @ 12 V,23 mA@ 24V 4WT-B Yes 4-wire 20 mA @ 12 V,23 mA @ 24 V Accessories 2W-MOD2 2-wire loop test/maintenance module RT Removal/replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket,6.6 inch(16.76 cm)diameter SYSTEM System Sensor. 3825 Ohio Avenue•St.Charles,IL 60174 Product speofieano»s subject to change A nhout notice msa systemsensorcom to, ,SENSORS Phone:800-SENSOR2•Fax:630-377-6495 current prod,crnnro,man°n includIng the latest version oem3 data sheet A05-0318-007.6/09•x2169 �1 1' M .' Yk,G � SYSTEM SENSOR® .1111111 • .. ,...::: milI IF ,x . 1 . . '. :::::. III 5 ,. Indoor Selectable- :� Output Horns, fi Strobes, and .` :#: , s Horn Strobes for Wall Applications System Sensor L-Series audible visible notification t -A. I -w ;, products are rich with features guaranteed to cut ; $ sem, -- ' installation times and maximize profits with lower current draw and modern aesthetics. ,.�- - �� Features • Updated Modern Aesthetics The System Sensor L.-Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Plug-in design with minimal intrusion into the back box plastic housings,standard and compact devices,and plain,FIRE, • Tamper-resistant construction and FUEGO-printed devices,System Sensor L-Series can • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela The L-Series line of wall-mount horns,strobes,and horn strobes • Field-selectable candela settings on wall units: include a variety of features that increase their application versatility 15,30,75,95, 110, 135,and 185 while simplifying installation.All devices feature plug-in designs • Horn rated at 88+dBA at 16 volts with minimal intrusion into the back box,making installations fast • Rotary switch for horn tone and two volume selections and foolproof while virtually eliminating costly and time-consuming ground faults. • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage,the L-Series utilizes a universal mounting plate for all • Electrically Compatible with legacy SpectrAlert and SpectAlert models with an onboard shorting spring,so installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range • Listed for wall mounting only of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING 04> LISTED APPROVED I I L-Series Specifications Architect/Engineer Specifications General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 1 7/8-inch back box,4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 17/e-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit'"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95,110,135,and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR12 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 1.91"D(143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions(including lens) 5.26"L x 3.46"W x 1.91"D(133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.25"D(143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25"L x 3.45"W x 1.25"D(133mm L x 88mm W x 32mm D) 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9` Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 Settings 9 and 10 are not available on the 2-wire horn strobes. L-Series Dimensions _ = 1.91 -3.46 -- - 3.46 - 1.25 1.25 r r 11,1111111.11111,1110000000000'' 1 1 1 1 1 1 00000000000 �101.1110.10 ,000000000002 5.27 1111 5.27 'Ioclogeo0o0i0 'Dorn 0o00ap0 ..-... .. IaIOIOIlI010 OIOIDI:I:I:I1 21. Compact Strobe/Horn Strobe Compact Horn 4.70 = 1.91 X4.70 1.25 T ..(-..-..,-,)._ = 1.25 4,1„--..__....., . roli • . , ,,,..:.,,.,., ,, 5.67 �I�I ".:�; "Hl."1,. Ell .67 �11i1i i1iF 11111 Nrq�, i�i�i�i�i�i 7 111 . ,_%ft-._...t) IC ,„.._ .,,,,,... Strobe/Horn Strobe Horn L-Series Ordering Information Model Description Model Description Wall Horn Strobes Horns P2RL 2-Wire,Horn Strobe,Red HRL Horn,Red , e 2-Wire,Horn Strobe,Mite HWL Horn,White P2GRL 2-Wire,Compact Horn Strobe,Red HGRL Compact Horn,Red P2GWL 2-Wire,Compact Horn Strobe,White HGWL Compact Horn,White P2RL-P 2-Wire,Horn Strobe,Red,Plain Accessories P2WL-P 2-Wire,Horn Strobe,White,Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire,Horn Strobe,Red,FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire,Horn Strobe,White,FUEGO SBBRL Wall Surface Mount Back Box,Red Wall Strobes SBBWL Wall Surface Mount Back Box,White SRL Strobe,Red SBBGRL Compact Wall Surface Mount Back Box,Red SWL Strobe,White SBBGWL Compact Wall Surface Mount Back Box,White SGRL Compact Strobe,Red SGWL Compact Strobe,White SRL-P Strobe,Red,Plain SWL-P Strobe,White,Plain SRL-SP Strobe,Red,FUEGO SWL-CLR-ALERT Strobe,White,ALERT Notes: All-P models have a plain housing(no"FIRE"marking on cover) All-SP models have"FUEGO"marking on cover All-ALERT models have"ALERT'marking on cover SENSOR*SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ©2017 system sensor. �.4 J Phone:800-SENSOR2•Fax:630-377-6495 Product specifications subject to change without notice Visit systemsensor.com for current product information,including the latest version of this data sheet. www.systemsensor.com AVose6502•o2rt7