Report (5) COMcheck Software Version 4.0.5.1
irrill Interior Lighting CompliancewF ` V.
Certificate cc:::
580PE1 - ,',
DEC 2 7 2016
•RFGOf+t to
Section 1: Project Information �� � � 94. %�,3 30,�6'1111: �
Energy Code: 2014 Oregon Energy Efficiency Specialty Code ��� � DIVISION '-. '*,N'W p %''
Project Title: Pink-Washington Square "*""�,,
Project Type:Alteration IRFSS:r-1307io i7 j
Construction Site: Owner/Agent: Designer/Contractor:
Space#H07 LBrands-Store Design&Construction M-Engineering
9585 S.W.Washington Square Three Limited Parkway 750 Brookesdge Blvd.
Portland,OR 97223 Columbus,OH 43230 Westerville,OH 43081
614-415-7000 614-839-4639
www.mengineering.us.com
Section 2: Interior Lighting and Power Calculation
A B C D
Area Category Floor Area Allowed Allowed Watts
(ft2) Watts/ft2 (B x C)
Sales(Retail:Sales Area)(Ceiling Height 0 ft.) 4125 1.5 6188
Allowance:Furniture,clothing,cosmetics highlighting/Fix. ID:track cl 858(a) 1.4 1200(b)
Allowance:Furniture,clothing,cosmetics highlighting/Fix. ID:track cl 858(a) 1.4 1200(b)
Allowance:Furniture,clothing,cosmetics highlighting/Fix. ID:track cl 858(a) 1.4 1200(b)
Allowance:Furniture,clothing,cosmetics highlighting/Fix. ID:track cl 858(a) 1.4 1200(b)
Allowance:Furniture,clothing,cosmetics highlighting/Fix. ID:track cl 693(a) 1.4 970(b)
Fitting Rooms(Retail:Fitting Room)(Ceiling Height 0 ft.) 698 1.06 740
Stocking(Warehouse:Fine Material Storage)(Ceiling Height 0 ft.) 846 1.53 1294
Break Room(Common Space Types:Lounge/Recreation)(Ceiling Height 0 ft.) 184 0.73 134
Restrooms(Common Space Types:Restrooms)(Ceiling Height 0 ft.) 88 0.82 72
•
Office(Common Space Types:Office-Enclosed)(Ceiling Height 0 ft.) 105 0.97 102
Hallways(Common Space Types:Corridor/Transition)(Ceiling Height 0 ft.) 335 0.41 137
Total Allowed Watts= 14438
•
(a)Area claimed may exceed total floor area when Retail Merchandise Highlighting allowance(s)are specified.
(b) Allowance is(B x C)or the actual wattage of the fixtures given in Section 2,whichever is less.
Section 3: Interior Lighting Fixture Schedule
A B C D E
Fixture ID:Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D)
Fixture Fixtures Watt.
Sales(Retail:Sales Area 4125 sq.ft.)
Track lighting 1:track cl:CIRCUIT BREAKER:Wattage based on circuit breaker capacity 0 0 1200 1200
(10 amps x 120 volts)
Track lighting 2:track cl:CIRCUIT BREAKER:Wattage based on circuit breaker capacity 0 0 1200 1200
(10 amps x 120 volts)
Track lighting 3:track cl:CIRCUIT BREAKER:Wattage based on circuit breaker capacity 0 0 1200 1200
(10 amps x 120 volts)
Track lighting 4:track cl:CIRCUIT BREAKER:Wattage based on circuit breaker capacity 0 0 1200 1200
(10 amps x 120 volts)
Track lighting 5:track cl:CIRCUIT BREAKER:Wattage based on circuit breaker capacity 0 0 1200 1200
(10 amps x 120 volts)
Track lighting 6:track cl:CIRCUIT BREAKER:Wattage based on circuit breaker capacity 0 0 960 960
(8 amps x 120 volts)
Led 1:ET3:ADJ.DOWNLIGHT:Other: 1 10 28 280
Led 2:EU2:ADJ.DOWNLIGHT:Other: 1 3 28 84
Linear Fluorescent 1:F4:4'STRIP FLUOR.:48"T8 32W:Electronic: 1 1 32 32
•
Project Title: Pink-Washington Square Report date: 12/15/16
Data filename: P:\1642xxx\1642222\06Design\09 Energy Code\1642222-Pink Washington Square.cck Page 1 of 4
Led 3:GL1:ADJ.DOWNLIGHT:Other: 1 4 18 72
Led 4:HA2:LED CAB LITE:Other: 1 2 9 18
Led 5:HA3:LED CAB LITE:Other: 1 10 11 110
_ Led 6:HA4:LED CAB LITE:Other: 1 37 15 555
Led 7:HA6:LED CAB LITE:Other: 1 3 21 63
Led 8:L10:LED DRIVER:Other: 1 3 408 1224
Induction 1:NA:NEON SIGNAGE:Other: 1 2 756 1512
Led 9:NH:LED SIGNAGE:Other: 1 1 148 148
Led 10: NR:LED SIGNAGE:Other: 1 1 148 148
Led 11:QA1:DOWNLIGHT:Other: 1 3 19 57
Led 12:QA2:DOWNLIGHT:Other: 1 2 19 38
Led 13:RF:GONDOLA:Other: 1 1 192 192
Led 14:S6:LED STICK LIGHTS:Other: 1 2 75 150
Fitting Rooms(Retail Fitting;Room 698 sq ft) 4
Led 15:B9:ADJ.DOWNLIGHT:LED MR 7W: 1 2 15 30
Induction 2:NA1:NEON SIGNAGE:Other: 1 1 756 756
Led 16:PL1:PENDANT:Other: 1 8 25 200
Led 11:QA1:DOWNLIGHT:Other: 1 5 19 95
Led 12:QA2:DOWNLIGHT:Other: 1 6 19 114
Led 17:W3:SCONCE:Other: 1 14 15 210
Stocking(Warehouse:Fiine Material Storage 846•sq ft
Linear Fluorescent 2:FG:4'STRIP FLUOR.:48"T8 32W:Electronic: 1 6 32 192
Linear Fluorescent 3:FR:4'STRIP FLUOR.:48"T8 32W:Electronic: 1 10 32 320
Break Room(Common Space Types:Lounge/Recreation 184 sq.ft.)
Linear Fluorescent 4:N3:ADJUSTABLE DROP:48"T8 32W:Electronic: 2 2 64 128
Linear Fluorescent 5:N3E:ADJUSTABLE DROP:48"T8 32W:Electronic: 2 2 64 128
Restroorris(Common Space Types:Restrooms 88 sq.ft.)
Led 16: PL1:PENDANT:Other: 1 1 25 25
Led 12:QA2:DOWNLIGHT:Other: 1 1 19 19
Linear Fluorescent 6:F2:2'STRIP FLUOR.:24"T8 17W:Electronic: 1 1 17 17
Office(Common Space Types:Office Enclosed 105 sq.ft.)
Linear Fluorescent 7:N2:4'SURFACE STRIP FLUOR.:48"T8 32W:Electronic: 1 1 32 32
Linear Fluorescent 8:N2E:4'SURFACE STRIP FLUOR.:48"T8 32W:Electronic: 1 1 32 32
Linear Fluorescent 9:PK: UNDERSHELF TASK LIGHT:35"T5 21W:Electronic: 1 3 21 63
Hallways(Common Space Types Corridor/Transition 335 sq.ft.)
Linear Fluorescent 2:FG:4'STRIP FLUOR.:48"T8 32W:Electronic: 1 2 32 64
Linear Fluorescent 3:FR:4'STRIP FLUOR.:48"T8 32W:Electronic: 1 3 32 96
Led 18:QA5:DOWNLIGHT:Other: 1 2 25 50
Led 19:QA6:DOWNLIGHT:Other: 1 1 25 25
Total Proposed Watts= 14239
Section 4: Requirements Checklist
In the following requirements,blank checkboxes identify requirements that the applicant has not acknowledged as being met. Checkmarks
identify requirements that the applicant acknowledges are met or excepted from compliance. 'Plans reference page/section'identifies where in
the plans/specs the requirement can be verified as being satisfied.
Lighting Wattage:
• 1. Total proposed watts must be less than or equal to total allowed watts.
Allowed Wattage: 14438 Proposed Wattage:14239
Complies:YES
Mandatory Requirements:
✓ 2. Exit signs. Internally illuminated exit signs shall not exceed 5 watts per side.
Plans reference page/section: E04.01
✓ 3. Daylight zone control.All daylight zones are provided with individual controls that control the lights independent of general area lighting
in the non-daylight zone.In all individual daylight zones larger than 350 sq.ft.,automatic daylight controls is provided.Automatic
daylight sensing controls reduce the light output of the controlled luminaires at least 50 percent,and provide an automatic OFF control,
while maintaining a uniform level of illumination.Contiguous daylight zones adjacent to vertical fenestration may be controlled by a
single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations(i.e.,north,east,
south,west).Daylight zones under skylights shall be controlled separately from daylight zones adjacent to vertical fenestration.
Plans reference page/section: N/A
Project Title: Pink-Washington Square Report date: 12/15/16
Data filename: P:\1642xxx\1642222\06Design\09 Energy Code\1642222-Pink Washington Square.cck Page 2 of 4
• 4. Interior lighting controls.At least one local shutoff lighting control has been provided for every 2,000 square feet of lit floor area and
each area enclosed by walls or floor-to-ceiling partitions.The required controls are located within the area served by the controls or are
a remote switch that identifies the lights served and indicates their status.
✓ Exception applies:Lighting for contiguous,single-tenant retail spaces.
Plans reference page/section:
• 5. Sleeping unit controls.Master switch at entry to hotel/motel guest room.
Plans reference page/section: N/A
• 6. Egress lighting.Egress illumination is controlled by a combination of listed emergency relay and occupancy sensors to shut off during
periods that the building space served by the means of egress is unoccupied.
Exception applies:Building exits as defined in Section 1002 of the Oregon Structural Specialty Code.
Plans reference page/section: E03.01
• 7. Additional controls.Each area that is required to have a manual control shall have additional controls that meet the requirements of
Sections 505.2.2.1 and 505.2.2.2.
Plans reference page/section: E03.01
• 8. Light reduction controls.Each space required to have a manual control also allows for reducing the connected lighting load by at least
50 percent by either
1)controlling(dimming or multi-level switching)all luminaires;or
2)dual switching of alternate rows of luminaires,alternate luminaires,or alternate lamps;or
3)switching the middle lamp luminaires independently of other lamps;or
4)switching each luminaire or each lamp.
• Exception applies:An occupant-sensing device controls the area.
Plans reference page/section:
• 9. Buildings larger than 2,000 square feet are equipped with an automatic control device to shut off lighting in those areas.This automatic
control device shall function on either:
1)a scheduled basis,using time-of-day,with an independent program schedule that controls the interior lighting in areas that do not
exceed 10,000 square feet and are not more than one floor;or
2)an occupant sensor that shall turn lighting off within 30 minutes of an occupant leaving a space;or
3)a signal from another control or alarm system that indicates the area is unoccupied.
Plans reference page/section: E03.01
✓ 10.Occupancy sensors in rooms that include daylight zones are required to have Manual ON activation.
Plans reference page/section: N/A
11.An occupant sensor control device is installed that automatically turns lighting off within 30 minutes of all occupants leaving a space.
Plans reference page/section: E03.01
• 12.Additional controls.An occupant sensor control device that automatically turns lighting off within 30 minutes of all occupants leaving a
space or a locally activated switch that automatically turns lighting off within 30 minutes of being activated is installed in all storage and
supply rooms up to 1000 square feet.
Plans reference page/section: E03.01
• 13.Occupant override.Automatic lighting shutoff operating on a time-of-day scheduled basis incorporates an override switching device
that: 1)is readily accessible,2)is located so that a person using the device can see the lights or the area controlled by that switch,or
so that the area being lit is annunciated,3)is manually operated,4)allows the lighting to remain on for no more than 2 hours when an
override is initiated,and 5)controls an area not exceeding 2,000 square feet.
• Exception applies: In malls and arcades,auditoriums,single-tenant retail spaces,industrial facilities and arenas,the area
controlled shall not exceed 20,000 square feet.
Plans reference page/section:
• 14.Holiday scheduling.Automatic lighting shutoff operating on a time-of-day scheduled basis has an automatic holiday scheduling feature
that turns off all loads for at least 24 hours,then resumes the normally scheduled operation.
• Exception applies: Retail stores and associated malls,restaurants,grocery stores,places of religious worship,theaters and
exterior lighting zones.
Plans reference page/section:
✓ 15.Exterior lighting controls.Lighting not designated for dusk-to-dawn operation shall be controlled by either a combination of a
photosensor and a time switch,or an astronomical time switch.Lighting designated for dusk-to-dawn operation shall be controlled by
an astronomical time switch or photosensor.
Project Title: Pink-Washington Square Report date: 12/15/16
Data filename: P:\1642xxx\1642222\06Design\09 Energy Code\1642222-Pink Washington Square.cck Page 3 of 4
Plans reference page/section: N/A
• 16.Tandem wiring.The following luminaires located within the same area shall be tandem wired:
1.Fluorescent luminaires equipped with one,three or odd-numbered lamp configurations,that are recess-mounted within 10 feet
center-to-center of each other.
2.Fluorescent luminaires equipped with one,three or any odd-numbered lamp configuration,that are pendant-or surface-mounted
within 1 foot edge-to-edge of each other.
Plans reference page/section: E04.01
• 17.Medical task lighting or arUhistory display lighting claimed to be exempt from compliance has a control device independent of the control
of the nonexempt lighting.
Plans reference page/section: N/A
✓ 18.Each dwelling unit in a building is metered separately.
Plans reference page/section: E05.01
Interior Lighting PASSES
Section 5: Compliance Statement
Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans,specifications and
other calculations submitted with this permit application.The proposed lighting system has been designed to meet the 2014 Oregon Energy
Efficiency Specialty Code requirements in COMcheck Version 4.0.5.1 and to comply with the mandatory requirements in the Requirements
Checklist.
/l. 1/ /2
Name-Title `Signature Date
Project Title: Pink-Washington Square Report date: 12/15/16
Data filename: P:\1642xxx\1642222\06Design\09 Energy Code\1642222-Pink Washington Square.cck Page 4 of 4