Loading...
Plans (79) k C_)c.s SQ;..\ c>cz.ok.A(.`)‘c)...--?tk,(2.... -14 I M (F/5),0/?--- 00 )---7 fir$' (r �`'� &) SCOPE NOTES OFFICECOPY 1) The area of work shown is to have fire sprinkler drops j j jj;;�� MAR p ry 2��� installed in a new ceiling (ceiling by others) changes to the CYi,'1�1 1 sprinkler system designed, fabricated and installed in accordance with NFPA 13 2013 and local standards. 2) The area of work is a [INSERT USE]. �` 3) This contract is limited to area of work shown. GENERAL NOTES 1) Area of work is to be protected as a [INSERT OCCUPANCY] per NFPA 13 2013. 2) All materials devices and hangers used on this project shall be UL Listed and/or FM Approved for use in fire protection systems. 3) See attached 'Equipment Data Submittal' for all applicable materials and equipment used in this project. 4) All new piping to be 1"black steel, Eddythread40 (or equivalent) with threaded ductile iron fittings cut in from existing heads. 5) Maximum spacing per head is as listed in Sprinkler Symbol table. 6) Any and all painting or paint preparation of piping to be by others. 7) Pipe hangers including on all armovers 2'-0" or longer to be CI 3 installed in accordance with NFPA 13 2013 and per local AHJ. I ii _O HANGER KEY 8) Sprinklers to be installed in accordance with NFPA 13 2013 and per the local AHJ. 1 Trimline Adjustable Band Hangar 9) All elevations measured from finished floor of existing building. 10) If field conditions result in a change to the shop drawing 0 2 " Threaded Rod installation in any way, contact the project engineer to verify ' proposed changes are compliant with NFPA 13 requirements. 3 Sammies for Wood 11) This print or drawing shall be used only with reference to 4 Wood Structure contracts of proposals of Wyatt Fire Protection, Inc. This print or frilk drawing shall not be copied for, reproduced for nor exhibited to • O outside parties. This print or drawing and any and all copiesr therefore shall be returned to Wyatt Fire Protection, Inc. upon 0 request. Nothing disclosed herein not publicly available shall be used without written permission from Wyatt Fire Protection, Inc. w J co HA\GES DETAIL . NOT TO SCALE §. 5 8 Z15 5 z.. K EN Ffl • ri , _ I1 � d , REVISIONS X>< I 1 3/719 PERNIT {, N0. DATE DESCRIPTION Io1I 9 0 111 ® ® I ■ �-- III R J! i - _ , WYATT 7t1- _• [ 909 5w.3umham �_ +� s Tg OR 9722.3 ' .. M area 0 1 work 50 1 684 2928 I `I 1 I o T� ��L-, 9095 SW BURNHAM ST 71 CARD OREGON 97223 —1 +� s (ROJEC 4-2928 C2 C1 , ` r—- . � s r PROJECT: I lI '—r— � � r .tom � � F • �' . PACSTAR COMMUNICATIONS (� {E ___ __ M I7 \__ "' r 15055 SW SEQUOIA PKWY #100 r. — —� a J�._ W a, ® H. PORTLAND, OR 97244 . , __, L 1--N--,-,- a_ —_ i. _ is ~ MATTHEW OLSON CONSTRUCTION; 5320 SW 1 N "'"• DOVER LN,PORTLAND,OR 97225 ..111.. CONTRACT NO. TM19-112 DRAWN BY A. NISHIHARA PARTIAL REF ECTED CEILING P AN C E Y PLA\ CHECKED BY A. NISHIHARA SCALE 1/4" = 1'-0" 1/4"=1'-0" NOT TO SCALE PERMIT NO. SHEET NUMBER: o' 2' 4' 8' F P 1 .0 1 OF 1 I