Report (40) L', .GAJO cq�- COMcheck Software Version 4.0.8.1 CI1Envelope Compliance Certificate'`._ _ ,wF ; �� , il U44x r,.F t: Section 1: Project Information Energy Code:2014 Oregon Energy Efficiency Specialty Code Project Title: Project Type: New Construction Envelope Compliance Method: Prescriptive Construction Site: Owner/Agent: Designer/Contractor: Building Location(for weather data): Tigard,Oregon Climate Zone: 4c Vertical Glazing/Wall Area Pct.: 25% Building Use:Area Type Floor Area 1-Multifamily: Nonresidential 41812 Section 2: Envelope Assemblies and Requirements Checklist Envelope PASSES Envelope Assemblies: R-Value Proposed Max.Allowed Component Name/Description Cavity Cont. U-Factor SHGC U-Factor SHGC Roof 1:Attic Roof with Wood Joists,[Bldg. Use 1 -Multifamily] 49.0 0.0 0.021 --- 0.027 --- Floor 1:Slab-On-Grade:Unheated,[Bldg. Use 1 -Multifamily] --- 10.0 0.540 --- 0.540 --- main west wall:Wood-Framed, 16"o.c.,[Bldg. Use 1 -Multifamily] 21.0 0.0 0.062 --- 0.064 --- window no projection:Vinyl/Fiberglass Frame,Other,[Bldg.Use 1 --- --- 0.270 0.400 0.350 0.400 -Multifamily] window 5'balcony projection:Vinyl/Fiberglass Frame,Other, --- --- 0.270 0.400 0.350 0.400 [Bldg. Use 1 -Multifamily] window 8'balcony projection:Vinyl/Fiberglass Frame,Other, --- --- 0.270 0.400 0.350 0.400 [Bldg. Use 1 -Multifamily] window ground floor projection:Vinyl/Fiberglass Frame,Other, --- --- 0.270 0.400 0.350 0.400 [Bldg.Use 1 -Multifamily] Door 14: Insulated Metal,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- main east wall:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Multifamily] 21.0 0.0 0.062 --- 0.064 --- window no projection:Vinyl/Fiberglass Frame,Other,[Bldg. Use 1 --- --- 0.270 0.400 0.350 0.400 -Multifamily] window 5'balcony projection:Vinyl/Fiberglass Frame,Other, --- --- 0.270 0.400 0.350 0.400 [Bldg. Use 1 -Multifamily] window 8'balcony projection:Vinyl/Fiberglass Frame,Other, --- --- 0.270 0.400 0.350 0.400 [Bldg. Use 1 -Multifamily] window ground floor projection:Vinyl/Fiberglass Frame,Other, --- --- 0.270 0.400 0.350 0.400 [Bldg.Use 1 -Multifamily] Door 15: Insulated Metal,Swinging,[Bldg. Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- north wall:Wood-Framed, 16"o.c.,[Bldg. Use 1 -Multifamily] 21.0 0.0 0.062 --- 0.064 --- no projection:Vinyl/Fiberglass Frame,Clear,[Bldg.Use 1 - --- --- 0.270 0.400 0.350 0.400 Multifamily] ground floor projection:Vinyl/Fiberglass Frame,Clear,[Bldg. Use --- --- 0.270 0.400 0.350 0.400 1 -Multifamily] south wall:Wood-Framed, 16"o.c.,[Bldg. Use 1 -Multifamily] 21.0 0.0 0.062 --- 0.064 --- no projection:Vinyl/Fiberglass Frame,Other,[Bldg. Use 1 - --- --- 0.270 0.400 0.350 0.400 Multifamily] ground floor protection:Vinyl/Fiberglass Frame,Other,[Bldg.Use --- --- 0.270 0.400 0.350 0.400 1 -Multifamily] Door 1: Insulated Metal,Swinging,[Bldg. Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- 21.0 0.0 0.062 --- 0.064 --- Project Title: Report date: 03/08/18 Data filename:\\Lkoae0l\proj\Project\17000\17052\Data\Com Check\building 2.cck Page 1 of 5 north inset west wall:Wood-Framed, 16"o.c.,[Bldg.Use 1 - , • Multifamily] north inset east wall:Wood-Framed, 16"o.c.,[Bldg. Use 1 - 21.0 0.0 0.062 --- 0.064 --- Multifamily] south inset east wall:Wood-Framed, 16"o.c.,[Bldg.Use 1 - 21.0 0.0 0.062 --- 0.064 --- Multifamily] south inset west wall:Wood-Framed, 16"o.c.,[Bldg. Use 1 - 21.0 0.0 0.062 --- 0.064 --- Multifamily] balcony 1 south:Wood-Framed, 16"o.c.,[Bldg.Use 1 - 21.0 0.0 0.062 --- 0.064 --- Multifamily] Door 2:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- balcony 1 north:Wood-Framed, 16"o.c.,[Bldg. Use 1 - 21.0 0.0 0.062 --- 0.064 --- Multifamily] balcony 2 south:Wood-Framed, 16"o.c.,[Bldg.Use 1 - 21.0 0.0 0.062 --- 0.064 --- Multifamily] Door 3:Wood,Swinging,[Bldg. Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 3 copy 1:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 3 copy 2:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 3 copy 3:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- balcony 2 north:Wood-Framed, 16"o.c.,[Bldg.Use 1 - 21.0 0.0 0.062 --- 0.064 --- Multifamily] balcony 3 south:Wood-Framed, 16"o.c.,[Bldg.Use 1 - 21.0 0.0 0.062 --- 0.064 --- Multifamily] Door 4:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 4 copy 1:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 4 copy 2:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 4 copy 3:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- balcony 3 north:Wood-Framed, 16"o.c.,[Bldg.Use 1 - 21.0 0.0 0.062 --- 0.064 --- Multifamily] balcony 4 south:Wood-Framed, 16"o.c.,[Bldg. Use 1 - 21.0 0.0 0.062 --- 0.064 --- Multifamily] Door 5:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 5 copy 1:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 5 copy 2:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 5 copy 3:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- balcony 4 north:Wood-Framed, 16"o.c.,[Bldg.Use 1 - 21.0 0.0 0.062 --- 0.064 --- Multifamily] balcony 5 south:Wood-Framed, 16"o.c.,[Bldg.Use 1 - 21.0 0.0 0.062 --- 0.064 --- Multifamily] Door 6:Wood,Swinging,[Bldg. Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 6 copy 1:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 6 copy 2:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 6 copy 3:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- balcony 5 north:Wood-Framed, 16"o.c.,[Bldg.Use 1 - 21.0 0.0 0.062 --- 0.064 --- Multifamily] Door 7:Wood,Swinging,[Bldg. Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 7 copy 1:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 7 copy 2:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 7 copy 3:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- balcony 6 south:Wood-Framed, 16"o.c.,[Bldg.Use 1 - 21.0 0.0 0.062 --- 0.064 --- Multifamily] balcony 6 north:Wood-Framed, 16"o.c.,[Bldg.Use 1 - 21.0 0.0 0.062 --- 0.064 --- Multifamily] Door 8:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 8 copy 1:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 8 copy 2:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 8 copy 3:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- balcony 7 south:Wood-Framed, 16"o.c.,[Bldg.Use 1 - 21.0 0.0 0.062 --- 0.064 --- Multifamily] balcony 7 north:Wood-Framed, 16"o.c.,[Bldg.Use 1 - 21.0 0.0 0.062 --- 0.064 --- Multifamily] Door 9:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 9 copy 1:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 9 copy 2:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Project Title: Report date: 03/08/18 Data filename:\\Lkoae01\prof\Project\17000\17052\Data\Com Check\building 2.cck Page 2 of 5 Door 9 copy 3:Wood,Swinging,[Bldg. Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- balcony 8 south:Wood-Framed, 16"o.c.,[Bldg. Use 1 - 21.0 0.0 0.062 --- 0.064 --- Multifamily] balcony 8 north:Wood-Framed, 16"o.c.,[Bldg.Use 1 - 21.0 0.0 0.062 --- 0.064 --- Multifamily] Door 10:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 10 copy 1:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 10 copy 2:Wood,Swinging,[Bldg. Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 10 copy 3:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- balcony 9 south:Wood-Framed, 16"o.c.,[Bldg.Use 1 - 21.0 0.0 0.062 --- 0.064 --- Multifamily] balcony 9 north:Wood-Framed, 16"o.c.,[Bldg. Use 1 - 21.0 0.0 0.062 --- 0.064 --- Multifamily] Door 11:Wood,Swinging,[Bldg. Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 11 copy 1:Wood,Swinging,[Bldg. Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 11 copy 2:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 11 copy 3:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- balcony 10 south:Wood-Framed, 16"o.c.,[Bldg. Use 1 - 21.0 0.0 0.062 --- 0.064 --- Multifamily] Door 12:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 12 copy 1:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 12 copy 2:Wood,Swinging,[Bldg. Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 12 copy 3:Wood,Swinging,[Bldg. Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- balcony 10 north:Wood-Framed, 16"o.c.,[Bldg. Use 1 - 21.0 0.0 0.062 --- 0.064 --- Multifamily] Door 13:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 13 copy 1:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 13 copy 2:Wood,Swinging,[Bldg. Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- Door 13 copy 3:Wood,Swinging,[Bldg.Use 1 -Multifamily] --- --- 0.500 --- 0.700 --- (a)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. In the following requirements,blank checkboxes identify requirements that the applicant has not acknowledged as being met. Checkmarks identify requirements that the applicant acknowledges are met or excepted from compliance. 'Plans reference page/section'identifies where in the plans/specs the requirement can be verified as being satisfied. Fenestration Product Rating: ❑ 1. U-factors of fenestration products(windows,doors and skylights)are determined in accordance with NFRC 100 by an accredited, independent laboratory,and labeled and certified by the manufacturer or are determined using the commercial size category values listed in Chapter 15 of the 2009 ASHRAE Handbook of Fundamentals,Table No.4 and shall include the effects of the window frame. The temporary label afixed to the fenestration products must not be removed prior to inspection. Exception(s): ❑ Site-built fenestration products shall have a single certificate specifying glazing type,special coatings,spacers,gas fills, center-of-glass and overall U-factor,and center-of-glass SHGC for every type of site built glass used.These certificates shall be maintained on the jobsite and made available to the inspector. Plans reference page/section: ❑ 2. Solar heat gain coefficient(SHGC)of glazed fenestration products(windows,glazed doors and skylights)shall be determined in accordance with NFRC 200 by an accredited,independent laboratory,and labeled and certified by the manufacturer or be determined using the Solar Heat Gain Coefficients(SHGC)in Chapter 15 of the 2009 ASHRAE Handbook of Fundamentals,Table No.10.The overall values must consider type of frame material and operator for the SHGC at normal incidence. Exception(s): ❑ Site-built fenestration products shall have a single certificate specifying glazing type,special coatings,spacers,gas fills, center-of-glass and overall U-factor,and center-of-glass SHGC for every type of site built glass used.These certificates shall be maintained on the jobsite and made available to the inspector. Plans reference page/section: Air Leakage, Insulation, and Component Certification: ❑ 3. Sealing of the building envelope.Openings and penetrations in the building envelope are sealed with caulking materials or closed with gasketing systems compatible with the construction materials and location.Joints and seams are sealed in the same manner or taped or covered with a moisture vapor-permeable wrapping material.Sealing materials spanning joints between construction materials allow for expansion and contraction of the construction materials. Plans reference page/section: Project Title. Report date: 03/08/18 Data filename:\\Lkoae0l\proj\Project\17000\17052\Data\Com Check\building 2.cck Page 3 of 5 p 4. Window and door assemblies.The air leakage of window and sliding or swinging door assemblies that are part of the building envelope are determined in accordance with AAMA/WDMA/CSA 101/I.S.2/A440,or NFRC 400 by an accredited,independent laboratory,and labeled and certified by the manufacturer. • Exception(s): Site-constructed windows and doors that are weatherstripped or sealed in accordance with Section 502.4.3. Plans reference page/section: • 5. Curtain wall,storefront glazing and commercial entrance doors.Curtain wall,storefront glazing and commercial-glazed swinging entrance doors and revolving doors are tested for air leakage in accordance with ASTM E 283.For curtain walls and storefront glazing, the maximum air leakage rate is 0.3 cubic foot per minute per square foot of fenestration area.For commercial glazed swinging entrance doors and revolving doors,the maximum air leakage rate is 1.00 cfm/ft2 of door area. 'Exception(s): Requirement is not applicable. Plans reference page/section: D 6. Building thermal envelope insulation.An R-value identification mark is applied(by manufacturer)to each piece of insulation 12 inches or greater in width.Alternately,the insulation installers have provided a signed,dated and posted certification listing the type, manufacturer and R-value of insulation installed. Refer to code section for blown or sprayed insulation installation/settling depths and marker requirements. D 7. Insulation mark installation.Insulating materials are installed such that the manufacturer's R-value mark is readily observable upon inspection. 8. Insulation product rating.The thermal resistance(R-value)of insulation has been determined in accordance with the U.S. FTC R-value rule. D 9. Installation.All material,systems and equipment are installed in accordance with the manufacturer's installation instructions and the International Building Code. • 10.Outdoor air intakes and exhaust openings.Stair and elevator shaft vents and other outdoor air intakes and exhaust openings integral to the building envelope shall be equipped with not less than a Class I motorized,leakage-rated damper with a maximum leakage rate of 4 cfm per square foot at 1.0 inch water gauge when tested in accordance with AMCA 500D.Stair and shaft vent dampers shall be capable of being automatically closed during normal building operation and interlocked to open as required by fire and smoke detection systems. Exception(s): • Requirement is not applicable. Plans reference page/section: • 11.Loading dock weatherseals.Cargo doors and loading dock doors are equipped with weather seals to restrict infiltration when vehicles are parked in the doorway. Exception(s): p Requirement is not applicable. Plans reference page/section: • 12.Recessed lighting. Recessed luminaires installed in the building thermal envelope are sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires are IC-rated and labeled as meeting ASTM E 283.All recessed luminaires are sealed with a gasket or caulk between the housing and interior wall or ceiling covering. Exception(s): D Requirement is not applicable. Plans reference page/section: • 13.Vestibules.Doors that separate conditioned space from the exterior are protected with an enclosed vestibule,with all doors of the vestibule equipped with self-closing devices.Vestibules are designed so interior and exterior doors to not operate simultaneously. Exception(s): p Doors not intended to be used as a building entrance door,such as doors to mechanical or electrical equipment rooms. p Doors opening directly from a sleeping unit or dwelling unit. p Doors that open directly from a space less than 3000 sq.ft.in area. • Revolving doors. LI Doors used primarily to facilitate vehicular movement or material handling and adjacent personnel doors. p Requirement is not applicable. Plans reference page/section: p 14.'Qther components have supporting documentation for proposed U-Factors. Exception(s): p Requirement is not applicable. Project Title: Report date: 03/08/18 Data filename:\\Lkoae0l\proj\Project\17000\17052\Data\Com Check\building 2.cck Page 4 of 5 Plans reference page/section: Section 3: Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application.The proposed envelope system has been designed to meet the 2014 Oregon Energy Efficiency Specialty Code requirements in COMcheck Version 4.0.8.1 and to comply with the mandatory requirements in the Requirements Checklist. Miffir /Jew, PIOM .144, Name-Title Signature Date Project Title: Report date: 03/08/18 Data filename:\\Lkoae0l\proj\Project\17000\17052\Data\Com Check\building 2.cck Page 5 of 5