Report (62) Fire Marshal's Offices , 1l1 Q c\
\60 APR 2 2018
TVP North Division South Division Eat Division
4755 SW Griffith Dr. 7401 SW Washo Court 320 Warner f l
Beaverton, OR 97076 Tualatin, OR 97062 PO Box 35 (41 °
(503)526-2469 (503)612-7000 Oregon City, OR 97045
Fax(503)526-2538 Fax(503)612-7003 (503)652-1365
Fax (503)657-791
Page 1 oft Building Survey Report
FMZ : (to be filled out by TVF&R) Code Edition: OSSC 2014
Name of Facility: The Fields Apartments
Name of Building: Building 3
Address: 7790 SW Hunziker Rd, Tigard, OR 97223
Owner:CBG Properties LLC Telephone No. ( 503 )86_4084
Architect: Otak Architects Inc Telephone No. ( 503 )415-2393
Architect Address: 808 SW Third Ave, Suite 300, Portland, OR 97204
ITEM COMM DESCRIPTION
1. Occupancy A-3 Type Clubhouse Ammenitiesluse Assembly Capacity 259
2. Construction Type VB Year Built 2018/2019
3. Area(Sq.Ft.) 3,342 Total Largest Floor None Basement None
4. Stories 1 No.
Height High Rise ElY ON
5 a. Exterior Wall Construction SC All WF non rated
b. Opening Protection None Not required due to fire separation distance.
6. Interior Wall Construction SC WF non rated and WF 1 hr rated separating S-2 Maintenance.
7. Floor Construction SC NR slab on grade
8. Roof Construction SC NR wood framed green roof, Class C
9. Attic Draft Stops None No. None Required
10a. Occ.Sep.Wall Construction 1 hr No. B/A-3 & B/S
b. Opening Protection None
1 la. Area Sep.Wall Construction None No. l
b. Opening Protection None
12a. Smoke Barrier Wall Construction None No. None Required
b. Opening Protection None
13a. Corridor Wall Construction None
b. Opening Protection None
14a. Corridor Ceiling Construction None
b. Opening Protection None
15a. Shafts None No. 0 yp
Type
b. Opening Protection None
Building Survey Report
FMZ : (to be filled out by TVF&R)
Name of Facility: The Fields Apartments
ITEM COMM. DESCRIPTION
16a. Stair Enclosure None No. 0
b. Opening Protection None
17. Stairs None No.0
18. Ramps None No. 0
19. Interior Finish Class Room Corridor Exit Enclosure
20. Exits YES No.9 Total Width 306"
21. Exit Hardware Type YES See hardware schedule
22a. Exit Signs/Illumination YES See electrical drawings
b. Emergency Lighting YES See electrical drawings
23. Auto Sprinkler Coverage YES Full Coverage NFPA 13
24. Standpipe Class/Locations NO N/A
25. Fire Alarm Type/Coverage YES Full Coverage
26. Heating,Ventilation&Air Conditioning SC Type split system Fuel Gas
27. Electrical Installation
28. Stage/Platform NO
29. Hazardous Area NO
30. Other
Comments:
Alternate Materials&Methods
TVF&R Use Only
Inspected By: Date No.Attachments
Reviewed By: I Date
Updated