Loading...
Plans (97) Pt S—C a-o ls— 00'4. 69'-10" -` N T rc N TM ,,,. U, in CC Deck Replacements 20'-11" 'p 4N ,'• 181-6"i N TT� I 7 V) i 1 1 I I 1 rTlExisting House Ce1 i CITY OF TIGARD 1 I Approved Ylanningi t — iDate:am9 - jI Initials: ..,_ 69'-10" Driveway SW Ventura Dr General Contractor Project Title Project Manager Drawing Title TnT Builders TnT Builders Inc Brent Mosser Site Plan- Revised 620 SW Queen Ave. Burke Deck Replacements Date Scale , 7 , id Albany OR 97322 7065 SW Ventura Dr February 14, 2019 1"=20' y r=,ar.. oaticcover expertt, CCB#105770 Tigard, OR 97223 Phone t (541) 926-3117 2x8 PT Joist 16" OC w/ LUS28Z Trex Transcend Deck Surface Existing House w/ 2x8 PT Ledger w/ (2) 4 1/2" SDS 12" 00 (2) DTT1 Z's (2) DTT1 Z's : ' Existing Existing Tree to remain _ N.---1 Ground-Floor Deck R 7r ii =to remain ll - 4x4 PT post i 1����I®1 �` w/AC44Z -1---' (-7,--- po �. '4 , a r-v F r-r-e , a.—%'� n 111111111111111111114 © / 2'-0"" 6'-3" 2'-0"= 4x6 PT post 11111111.1.111•1 �/ _ — - - - ---- w/ AC44Z � � 00 �_ e 1 -- Existing 2x12 PT stringers 12" 00 Ground-Floor Deck • to remain 36" Trex Reveal guard rail 4x8 PT beam (typ) - -no gap large enough to fit 4" diameter sphere -grab rail on one side of stairs VT' -(see Guardrail Attachment Detail) �� Z ?C' , ICI 2x8 PT framed landing / 7'-8" 2'-6" ledgered to lower deck f w/ (2) 4 1/2" SDS 12" 00 ---- 10'-2" 1 Aluminum spiral staircase -center support column anchored to top of deck beam per manufacturer's specs General Contractor Project Title Project Manager Drawing Title TnT Builders TnT Builders Inc Brent Mosser First Floor Framing Plan - Revised 620 SW Queen Ave. Burke Deck Replacements Date Scale 7 g Albany OR 97322 7065 SW Ventura Dr February 14, 2019 1/4"= 1' .'irckaan(Tpa'. _cwnrc per-ct, CCB#105770 Tigard, OR 97223 Phone f (541)926-3117 Existing House Existing Tree to remain (2) DTT1Z's -deck framed around (2) DTT1Z's existing tree trunk -�— / - 2x; "' oast ;" OC w/ LIIu�28Z M If Tre T - -_ d Deck Surface - \- o - ,' / w/ 2x8 PT Ledger w/ (2) 4 1/2" SDS 12" OC O °° ____L,1___` Doubled joists on either side I c Y -LUS28Z (typ) tr' =nom 1 1 SII L0 i 6x6 PT post ` _--�- t � 6x12 PT beam (typ) w/AC66Z t ti M I � (tYp) acv , I I ... o 7'" C12'-6"d front rim 12'-3" \2'-8" / t Z / oI •{-- ® L 28'-0" t o t 0 ,(- u� .c Aluminum spiral staircase w/ 2'6" g'-C E New second-story deck post square upper landing lagged to deck X = m integrates into existing ground-floor beam per manufacturer's specs Lu C9 ° deck handrail 36"Pup Universal guard rail w/ glass rail panels -no gap large enough to fit 4" diameter sphere -grab rail on one side of stairs -(see Guardrail Attachment Detail) General Contractor Project Title Project Manager Drawing Title TnT Builders TnT Builders Inc Brent Mosser Second Floor Framing Plan - Revised �} 620 SW Queen Ave. Burke Deck Replacements Date Scale +'j 1. Albany OR 97322 7065 SW Ventura Dr February 14, 2019 1/4"= 1' .4ncksora potic covrrrxprrt, CCB #105770 Tigard, OR 97223 Phone (541)926-3117 4. a) i 0 c X W 1 :ij l 1 1 � m i, l N H i 0) I T— X f _r W R R R qj. R P -y N11144)�',�}, 1 AA. 1,//I 111�- Iks�kY� II II I WGI —bP 7 , i . 1 ' towe_, r-Beek VC7Gn tv i - C General Contractor Project Title Project Manager Drawing Title TnT Builders TnT Builders Inc Brent Mosser Elevation Plan-Revised 620 SW Queen Ave. Burke Deck Replacements Date Scale , ' ,7 R Albany OR 97322 7065 SW Ventura Dr February 14, 2019 1/4'= 1' .deck drid parte covarrxper„', CCB#105770 Tigard, OR 97223 Phone (541)926-3117