Loading...
Plans (54) max, • • FEB 1S-2019 • iwx ,1JG DIVISION FEB I Building Plans for City of Tigard Building Permit Application BUILDING DIVISION Customer: The Fountains at Summerfield condominiums HOA 15685 SW 116th Ave., #105 Tigard, OR 97224 Contact - Paul Brock, 858-212-9105, pbrock987(agmail.com Contractor: Jon Erickson, 503-730-9220 jon.eveniobsPgmail.com CCB 162397 Scope of Work–Repair Decks • Replace perimeter joists with PT • Repair joist and soffit dry rot OFF ( F copy • Re-coat deck surface with Gaco • Replace 42" guardrail and infill to comply with IBC multi-family code CITY OF TIGARD REVIEWED FOR CODE COMPLIANCE Approved: jam] OTC: [ ] Permit#: F q]f ,_0 j —•t7C9 0 z File Location: Fountains Deck Permit Plans REVISED.pptx Address: e 7 )." ��i �� e Suite#:/lie..)/ C� By: Date: � c:-/ 2/11/19 Fountains at Summerfield - Deck Building Plans 1 Typical Deck Construction and Size — 102 SF < > Brick Col. 114.5" �x iri5 Imbedded 6x6 PT 4---- 4x4 PT Posts A F _ < 2 x 8 PT blocking between joists attached with ' Three 16D 3-1/2"n HDG < 43" >< '15�� >< ) Ref: 2014 Oregon Structural 56.5" Specialty Code-Table 2304.9.1-29 2"x8"Joists 16" OC Blocking supports Simpson Rim joist attached to ❑ Tension Ties DTT2Z. Two lateral joists with / DTT2Z brackets required for Three 16D 3-1/2"n HDG ------> j posts in this position. See Beam^' 6"x10" Simpson Wood Connection Ref: 2014 Oregon Connectors 2018-18 Deck Structural Specialty ^ Tension Ties- page 337 Code-Table a; N 2304.9.1-29 �' House-Brick exterior . 43" > - zScale- 12"/increment v r~_J 2/11/19 Fountains at Summerfield - Deck Building Plans 2 Water Penetration Remediation — Cross Section inginuniii Posts—4x4 PT Flashing 2" x 3" VResurfacing material 3/4" exterior plywood decking Ln 'o E Cc x N IC"---------- Hardi-plank Fascia 9.25" x .25". Applied with exterior adhesive and secured with post bolts. Wicking protection for soffit provided by%" extension. Pre-paint before adding flashing %" plywood soffit 7' Scale— 1" increment ......o s 2/11/19 Fountains at Summerfield - Deck Building Plans 3 Guard Rail Post — Simpson Tension Ties Posts-4x4 PT ' $ Simpson DDT2Z � Attach to lateral joist with 8 SDS 1.5" screws %" x 6" Machine Bolt � HDG with nuts and DTT2Z supports 1800 lb. ' - tensionforguardrails. load. Meets washers Code multi-family deckIBC Co o x Refer to attached mpson catalog - Deck TensionSiTies Lateral Joist Also pageoSi337 fr tmpsocd compliant reeGuardrailn o Poste- Connection bulletin T-C-GRDRLPST17 Scale- 1" increment 2/11/19 Fountains at Summerfield - Deck Building Plans 4 Typical Guardrail and Infill Section — 50" max. between posts i Simpson Strong Drive A Wide Screw SDWS 4", Railing 2 x 4 TKC 2 3/8"TL. Two per Cap Rail—Trex I l beto end, three in mid span 1" x 5.5" attached to Railing with exterior adhesive. N Railing Supportcri 2x4TKC . a o Attached to /11a ri Railing and Installation of Posts with r balasters and rails adhesive and per mfg installation Simpson instructions. Strong Drive Wide Screw SDWS 4", 2 3/8"TL. Railing 2 x 4 TKC Railing Infill - DecKorator aluminum `/ _ 2.75" space balaster%" x 32". Spacing 3.75" DecKorator Scale 1" increments CodeCompliance Research Report i 1 , I CCRR-0161 2/11/19 Fountains at Summerfield -Deck Building Plans 5 of 5