Loading...
Permit (158) CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT !NI COMMUNITY DEVELOPMENT Permit#: FPS2019-00027 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 03/06/2019 T t C.;k I=.t, g Parcel: 2S113BA00400 Jurisdiction: Tigard Site address: 7632 SW DURHAM RD 120 Project: Heritage Bank Subdivision: None Lot: None Project Description: Fire sprinkler. Adding(1)and removing(1)sprinkler for TI. Contractor: PATRIOT FIRE PROTECTION INC Owner: PORTLAND SW CENTER LLC 4708 NE MINNEHAHA ST BY FELTON PROPERTIES INC VANCOUVER,WA 98661 ATTN: FELTON, MATT 520 SW 6TH AVE, STE 610 PORTLAND,OR 97204 PHONE: 360-699-4403 PHONE: FAX: 360-699-4485 FEES Description Date Amount Specifics: Permit Fee-COM 03/05/2019 $53.78 12%State Surcharge-Building 03/05/2019 $6.45 Type of Use: COM Plan Review-Fire Life Safety-COM 03/05/2019 $21.51 Class of Work: ALT Type of Const: Info Process/Archiving-Lg$2.00(over 03/05/2019 $2.00 Occupancy Grp: Height: ft 11x17) Stories: Misc Administration Fee 03/06/2019 $5.00 Commercial Sprinkler System: Sprinkler Required: Sprinkler Type: Wet Standpipe Required: Hazard: LT Density: .10 Design Area: 0 K Factor: 5.6 Commercial Fire Alarm System: Fire Alarm Required: Alarm Type: Pull Station Required: Smoke Detectors Req: Battery Calcs Provided: Cut Sheets Required: Total $88.74 Valuations: Required Items and Reports(Conditions) Sprinkler Valuation: $550.00 Residential Square Footage: 0 Fire Alarm Valuation: $0.00 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: r /� 1 Permittee Signature: .rte Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project Approved plans are required on the job site at the time of each inspection. Building Permit Application Fire Protection System roiz(mitt: t sl:()NI.) City of Tigard LD ''' Received o. `- Lra DateBy: 3 'l l4 -•t° P- 9176, / —0a.,Z7 , 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review Phone: 503.718.2439 Fax: 503.598.1960 Date/By: '"j gt%L 7Ute`// I I c;A F"D Inspection Line: 503.639.4175 i� Date Ready/By: Vi9 id rws ® See Page 2 for Internet: www.tigard-or.gov otified/Me od: Supplemental Information TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING ❑New construction ❑Demolition Pe • fees*are based on the value of the work perfo. ed. Indicat- e value(rounded to the nearest dollar)o 41 ®Addition/alteration/replacement 0 Other: equipmen, t aterials,labor,overhead,and the p •fit for the CATEGORY OF CONSTRUCTION work indicate.on this application. 0 1-and 2-family dwelling SCommercial/industrial Valuation: $ • 0 Accessory building ElMulti-familyNumber of bedroom ❑Master builder 0 Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: 7632 SW Durham Rd New dwelling are. quare feet City/State/ZIP: Tigard, OR 97224 Garage/carpo area: squ..e feet Suite/bldg./apt.no.: 120/125 Project name:Heritage Bank TI Covere• .orch area: square -• • Cross street/directions to job site: SW Durham Rd and SW 79th Ave De area: square feet I her structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: I Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION°OF WORK work indicated on this application. Add (1)and remove (1) sprinkler for tenant improvement. Valuation: $ 550 Existing building area: same square feet New building area: same square feet 0 PROPERTY OWNER Ej TENANT Number of stories: 3 Name: Heritage Bank Type of construction: 2B Address: 7632 SW Durham Rd, Suite 120/125 Occupancy groups: City/State/ZIP:Tigard, OR 97224 Existing: B Phone:(503) 924 2312 Fax:( ) B New: 18:1 APPLICANT 0 CONTACT PERSON NOTICE Business name: Patriot Fire Protection, Inc All contractors and subcontractors are required to be Contact name: Ted Baker licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: 4708 NE Minnehaha Street jurisdiction in which work is being performed.If the City/State/ZIP: Vancouver, WA 98661 applicant is exempt from licensing,the following reasons apply: Phone:(360) 699 4403 Fax::(360 ) 699 4485 E-mail: joseph.plattner@patriotfire.com CONTRACTOR BUILDING PERMIT FEES* Business name: same as above (Please relertofee schedule) Permit fee: Address: City/State/ZIP: State surcharge(12%of permit fee): FLS plan review(40%of permit fee): Phone:( ) Fax:( ) (Due upon application submittal.) CCB lic.: 70822 (2 /2—.2-12-0 Total permit fees: Amount received: r Authorized signature: 1, j / This permit application expires if a permit is not obtained Print name: Joseph Plattner Date: 2-26-1 9 within 180 days after it has been accepted as complete. * Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Pemuts\FPS-PermitApp_071514.doc 440-4613T(11/02/COM/WEB) City of Tigard: Fire Protection Permit Checklist Page 2-Supplemental Information Describe work to be done: 1.) Type of Work: 2.) Addition/alteration only to sprinkler heads: 3.) Addition/alteration only to alarm devices: 0 New system Number of sprinkler heads: 4 Number of alarm devices: ❑ Addition or IK] 1-10 heads: Affidavit required and ❑ 1-5 devices: Affidavit required and Alteration (3)copies of sketch showing area (3) copies of sketch showing area to existing of work within building structure of work within building structure system 0 11+heads: Plan review required and 0 6+devices: Plan review required and (3) sets of plans. (3)sets of plans. Additional description of work: Type of System(Complete A,B,C or D as applicable): A.) Commercial Sprinkler ® Wet 0 Dry Additional Standpipes no Information: Hazard Group light Density .10 (existing) Design Area N/A K Factor 5.6 Sprinkler Project Valuation: $ 550 B.) Type I Hood Fire Suppression System Hood Project Valuation: $ C.) Fire Alarm Submittal shall Battery Calculations 0 Yes include: Individual Component 0 Yes Cut Sheets Fire Alarm Project Valuation: $ rat Sprinkler Alnne. re n-t __. .. _ __. .,..T..._. ..,. m.,. Square Footage: Permit Fee: 0 to 2,000 $198.75 2,001 to 3,600 $246.45 3,601 to 7,200 $310.05 7,201 and greater $404.39 Sprinkler Project Square Footage: sq.ft. Fire Protection Permit Fees Project valuation subtotal(see A,B&C above): $ Permit fee based on project valuation(see fee schedule): $ Permit fee based on square footage(see D above): $ State Surcharge (12%of permit fee): $ FLS Plan Review(40%of permit fee): $ TOTAL: $ \\patriotfire.local\dfs\VAN Profiles\ted.baker\Downloads\FPS_PermitApp.doc 2 City of Tigard Permit No.: -F-Ps2O(7—ck2ol 13125 SW Hall Blvd.,Tigard,OR 97223 y Phone: 503.718.2439 Fax: 503.598.1960 Date Received: 3 / Inspection Line: 503.639.4175 / 1 '' i' Internet: www.tigard-or.gov By: FIRE SPRINKLER AFFIDAVIT FOR ALT TIONSRECri\IFD OR TENANT IMPROVEMENTS FEB 2 8 2019 (1 to 10 SPRINKLER HEADS WITHOUT PLANS) BUILDING L}I'VI:ION Project Name: Heritage Bank TI Occupancy: B Job Address: 7632 SW Durham Rd Type of Construction: 2-B Suite: 120/125 Contractor: Patriot Fire Protection Phone: (360) 699 4403 Number of Proposed or Altered Heads: 2 Type: Reliable Fl Hazard:light Density: •10 I, Joseph Plattner Oregon Construction Contractors Board No. 70822 certify the following is true and reasonably defines the scope of work for this project: a) All work is limited to drops and armovers in a light-hazard occupancy. b) Positions of sprinkler heads relative to architectural features such as soffits,beams,partitions,walls, etc. complies with current adopted edition of NFPA 13. c) The proposed work does not require hydraulic calculations. d) Only one sprinkler head will be installed from one drop(exception: up to two heads from one drop may be installed when each head is in a separate fire area). e) The area covered per sprinkler head is limited to the spacing requirements of NFPA 13. f) Tenant improvements in a new building shall be equipped with Quick Response heads(see 2002 NFPA 13, Section 8.3.3.1 for exceptions). g) The installation shall comply with the requirements of the current adopted edition of NPFA 13. h) Piping shall not be concealed until hangers and bracing are inspected. i) Final approval shall be subject to onsite tests and inspections. In addition,I understand the following is required: • Submit(3)copies of a sketch showing the area of work within the building's structure. • Building fire protection system permit. • A copy of this document with a copy of the sketch attached shall be available for all inspections. Signature: Joseph Plattner ONaw "«=1 ....a� 2/26/19 D.1e:f0M022615.0310408W Date: Print Name: Joseph Plattner I:\Building\FormskFireSprinklerAffidavit 071514.docx Page 1 of 1 TRANSMITTAL DATE: 2-26-19 To: City of Tigard Building Dept. 13125 SW Hall Blvd Tigard, OR 97223 Att: Plans examiner From: Joseph Plattner re: Heritage Bank T.I. fire sprinkler submittal Job Number: 32-14780 Enclosed you will find (3) FP1 sprinkler plan, (3) sprinkler data sheets, (1) permit application and (1) permit affidavit. Please feel free to call with any question. Thank you, Joseph Plattner OR CCB 70822 WA PATRIFP099CF ATR OT JOSEPH PLATTNER-DESIGNER FIRE PROTECTION D 360 816 8724 C 360.409.3860 I JOSEPH.PLATTNER C(DPATRIOTFIRE.COM 4708 NE MINNEHAHA STREET I VANCOUVER,WA 98661 I P 360 699 4403 I F 360.699.4485 City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 7632 SW DURHAM RD 120, TIGARD, OR, 97224 Record Type: Record ID: Commercial - Fire Protection System FPS2019-00027 Inspection Type: Inspector: 999 Sprinkler final Jeff Grove Result: PASS - NoCofO Comments: Violation Summary: Inspector Contractor