Report • •
Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: -
- DOL42� 1 O F TtC-A1Q A
Site Address: S \°\ Cc s t S \-A13 E D�LT l ��j Oa_.
Subdivision/Lot#: Vl2 T2_10E,
and/or
Map and Tax Lot#:
By my signature below, I certify that a minimum of fifty(50)percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential Specialty Code N1107.2)1
Signature: _ Date: (2-1 21 1 9-D19
►. ctor/AuthorizeAgent
Print Name:C/%UCLA &Had S1 JS 5J
ORSC Section N1107.2.High-efficiency interior lighting systems. A minimum of fifty(50)percent o the
permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that
has a minimum efficacy of 40 lumens per input watt. Screw-in compact fluorescent lamps comply with this
requirement.
The building official shall be notified in writing at the fmal inspection that a minimum of fifty percent of the
permanently installed lighting fixtures are compact or linear fluorescent,or a minimum efficacy of 40 lumens per
input watt.
I:\Building\Fonns\RES-HighEfficiencyLighting.doc 07/01/08
0 0
Oregon Residential Specialty Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
I, , CE.Lftc. ( k (LtSTrSfiI, am the general contractor or the owner-builder
at the following address:
Site Address: I S ' ' _, Bina f',S s E ---PD 2T I_AiLs J i D 2_
City:
CAT6- r "TIan12-6
Permit#:
MST 201-4- —QQ A-251
Subdivision/Lot#: 1`.E 2(v t�- r Pic F
and/or
Map and Tax Lot#: '3--±
To conform with the 2017 Oregon Residential Specialty Code(ORSC), Section R408.1
Ventilation. I am notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
requirement:
IV
The ground surface of the under-floor space is covered by a Class I vapor retarder or
o er approved materials,with
vr,,,,
J 'nts lapped 12 inches at seams and
Extending up the foundation walls 12 inches.
/
Signature: 4 4, Date: 212,/ 20 /1
*, wner-Bui; al C�n+ - or �caner Bui rer
I:\Building\Form\RES-MoistureBarrierAcknowledgement_022018
•
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
I, Ate..E.LA , am the general contractor or the owner-builder
at the following address:
Site Address: ' C 119 1
91 S w T t S rL LPO. O 2
City: C4—,id- by ►CC AY1AN
Permit#: ISI 20 -00 429
Subdivision/Lot#: krE 21 Z (- l2 i2Ac E
and/or
Map and Tax Lot#: ?�
To conform with the 2008 Oregon Residential Specialty Code(ORSC), Section 8318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes,the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
Signature: /.411 _ Date: 2 21 9
Ge . 'tor Owner-Builder
I:\Building\Form\RES-MoistureSensitiveWood.doc 09/25/08