Permit (82) CITY OF TIGARD BUILDING PERMIT 4. F1111 2. '• COMMUNITY DEVELOPMENT Permit#: BUP2019-00003 Date Issued: 02/19/2019 r(GAR D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S101AA02900 Jurisdiction: Tigard Site address: 12123 SW 69TH AVE Project: Compass Oncology Subdivision: WEST PORTLAND HEIGHTS Lot: B Project Description: A one-story cast-in-place concrete vault,to be used for cancer therapy. Contractor: TURNER CONSTRUCTION CO Owner: SDC TIGARD CORPORATE CENTER INC 375 HUDSON ST ATTN:ANDREW HARPER NEW YORK, NY 10014 101 CALIFORNIA ST,26TH FLOOR SAN FRANCISCO, CA 94111 PHONE: 503-226-9825 PHONE: FAX: FEES Specifics: Description Date Amount Type of Use: COM DC Provision Review,COM TI-Ping 01/07/2019 $388.00 Class of Work: ALT Type of Const: IIB Occupancy Grp: B Occupancy Load: 3 Permit Fee-Additions,Alterations, 01/07/2019 $6,744.95 Demolition Dwelling Units: 012%State Surcharge Building 01/07/2019 $809.39 Stories: 1 Height: 0 ft Plan Review 01/07/2019 $4,384.22 Bedrooms: 0 Bathrooms: 0 Plan Review-Fire Life Safety 02/19/2019 $2,697.98 Value: $1,200,000 Metro Const.Excise Tax 01/07/2019 $1,440.00 Info Process/Archiving-Lg$2.00(over 01/07/2019 $70.00 11x17) Floor Areas: Wash Co Trans Dev Tax 02/19/2019 $23,267.00 Tigard Trans SDC Improvement 02/19/2019 $8,968.00 Total Area: 1902 Tigard Trans SDC Reimbursement 02/19/2019 $514.00 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $49,283.54 Required: Required Items and Reports(Conditions) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Ce -r. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232. •r .800.332.2344. Issued By: Permittee Signature: .. fr , , > if 03.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Division Accessibility: Barrier Removal Improvement Plan TIGARD REQUIREMENT: OREGON REVISED STATUTE (ORS)447.241. (1) Every project for renovation,alteration or modification to affected buildings and related facilities shall be made to insure that the path of travel to the altered area and the restroom, telephones and drinking fountains are readily accessible to individuals with disabilities unless such alterations are disproportionate to the overall alterations in terms of cost and scope. (2) Alterations made to the path of travel to an altered area may be deemed disproportionate to the overall alteration when the cost exceeds twenty-five per-cent(25%). VALUATION: Total of all renovation,alteration or modification being done, excluding painting and wallpapering: [1] $ 1200000 MULTIPLIER(25%barrier removal requirement): x .25 TOTAL BUDGET FOR BARRIER REMOVAL: [2] $ 300000 ELEMENTS: In choosing which accessible elements to provide under this section,priority shall be given to those elements that will provide the greatest access. Elements shall be provided in the following order: (a) Parking $ (b) An accessible entrance: $ (c) An accessible route to the altered area: $ (d) At least one accessible restroom for each sex or a single unisex restroom: $ (e) Accessible telephones: $ (f) Accessible drinking fountains:and, $ (g) When possible,additional accessible elements such as storage and alarms: $ TOTAL(shall equal line [2] of Valuation Computation): $ I:\Building\Permits\BUP-COM PermitApp.doc 03/03/2011 • Branden Taggart From: Branden Taggart Sent: Thursday, December 20, 2018 4:18 PM To: 'Reid, Bruce - (POR)' Cc: #Building Permit Technicians Subject: RE: McKesson - Compass Oncology Attachments: Branden Taggart.vcf Hi Bruce, Per our phone conversation, I have created fee estimates for the Compass Oncology site work permit and medical vault building permit with their respective valuations below. The plan review fees listed below will be due upon submittal. You are welcome to pay this fee in person or online after submitting. Also, I did not include the archiving fees, which are $.50 per page for pages up to 11" x 17" and $2.00 per page for pages over 11" x 17 for one complete set of plans. Furthermore, as we discussed, we will be open on the December 26 and 27. Please let me know if you have questions. "a a lu-e( i—w;tr ac9 ar '`r'a k 9 v Fee Utak $5,545 36 Ear„Ram QigarllitY WU Etas PetratiLee ..54a_Work 1 Each $2.09 92 wtDaveloement 1 Each $536 40 122itt umb mq - J 1 Each $330.59. etariAtroow 1 Each $1,830 4 5 Value(Contractor)$1,200,000.00: DC PIDvtci r'i Review<COC I TI.Pir 1 Each S I 00 Permit Et -Additions,Att ra turas;Demolition 1 ' Each $6,744.95 12'tt Stats tit:. ,^..:N a 'athiding 1 Ea.tt K 119,39 Puri Review 1 Each $4,384:22 ite i' ! „ xcgs og 1Each $1,44000 Thank you, Branden Taggart it $ City of Tigard ;< Senior Permit Technician ;N h,rq Community Development TV;APO 13125 SW Hall Blvd Tigard,OR 97223 (503)718-2449' brandent@tigard-or.gov From: Reid, Bruce - (POR) [mailto:breid@tcco.com] Sent:Thursday, December 20, 2018 11:38 AM 1 To: Branden Taggart<brandent@tigard-or.gov> Subject: McKesson -Compass Oncology Hi Branden- We are getting ready to submit the Site/Vault documents for permit. Is your office open 12/26 & 12/27? I'd like to submit the documents on one of those days. Also, has your office provided an estimate of plan check/building permit fees for the Site/Vault package yet? I'll need to request a check, so I'll need to know amount. Thanks, and have a great holiday ! Bruce Reid,LEED AP BD+C I Sr. Project Manager Turner Construction Company I mobile 503-572-2499 1073 Oak St.SE I Salem, OR 97301 2 Branden Taggart From: Branden Taggart Sent: Monday, January 7, 2019 4:38 PM To: Reid, Bruce - (POR) Cc: #Building Permit Technicians Subject: RE: Compass Oncology - Plan Check/ Bldg Permit Receipt Attachments: Compass Oncology Receipts.pdf Hi Bruce, I have attached the receipts for the Compass Oncology site work and building permit that you submitted earlier. We were fairly busy after you left, which is why it took longer to send these to you. Also, I confirmed today that Fire and Life Safety plan review would need to be collected for the medical vault building permit. My estimate for the building permit did not include this fee. I am certain I verified this before the estimate with our plans examiner, but either way, we will need to collect this fee once the permit is ready to issue. Fire and Life Safety plan review will be$2,697.98 based on the valuation of$1,200,000.00. I apologize for the inconvenience. Please let me know if you have questions. Thanks, Branden Taggart Illi q City of Tigard s Senior Permit Technician 1 C �iy CommunityComDevelopment 13125 SW Hall Blvd Tigard,OR 97223 (503)718-7449 brandent@tigard-or.gov From: Reid, Bruce-(POR)<breid@tcco.com> Sent: Monday,January 7, 2019 3:49 PM To: Branden Taggart<brandent@tigard-or.gov> Subject: Compass Oncology- Plan Check/ Bldg Permit Receipt Hi Branden- Will you still be able to send me a copy of the receipt today for the$19k in plan check and building permit fees? My accounting dept is hounding me for it. Thanks, Bruce Reid,LEED AP BD+C I Sr. Project Manager Turner Construction Company I mobile 503-572-2499 1073 Oak St.SE I Salem, OR 97301 1 Branden Taggart From: Branden Taggart Sent: Tuesday, February 12, 2019 10:40 AM To: Reid, Bruce - (POR) Cc: #Building Permit Technicians; Dennis.Escobar@corgan.com Subject: Compass Oncology Vault Permits: BUP2019-00003 & SIT2019-00001 - 12123 SW 69th Ave. Attachments: SIT2019-00001_Compass Oncology_021219.pdf; BUP2019-00003_Compass Oncology_ 021219.pdf Hi Bruce, The concrete vault permits for Compass Oncology are ready to issue now. I have attached invoices above for you to reference, and the fees due are as follows: Compass Oncology Permit# Fees Due BUP2019-00003 $ 35,446.98 S1T2019-00001 $ 440.00 Total: $ 35,886.98 You can pick up these permits between the hours of 8:00 a.m. and 4:30 p.m., Monday through Thursday. We are closed on Fridays. You are welcome to pay the fees in person or online through our website: https://aca.accela.com/TIGARD/Default.aspx. From there, click on the Building tab, enter the permit numbers in the Record Number field, and click Search. Once you pay online, please notify us at tigardbuildingpermits@tigard- or.gov. Also, I would like to reiterate that both permits must be picked up at the same time since they are on the same plans. If you have questions, please let me know. Thank you, Branden Taggart City of Tigard x ;,;U Senior Permit Technician Community Development TWARD 13125 SW Hall Blvd Tigard,OR 97223 (503)718-2448 brandent@tigard-or.gov DISCLAIMER: E-mails sent or received by City of Tigard employees are subject to public record laws. If requested, e-mail may be disclosed to another party unless exempt from disclosure under Oregon Public Records Law. E-mails are retained by the City of Tigard in compliance with the Oregon Administrative Rules "City General Records Retention Schedule." 1 City of Tigard COMMUNITY DEVELOPMENT DEPARTMENT 1 T1caRD Building Permit Review — Commercial - With Land Use ra , Building Permit #: ._t__�fi- Site Address: 12123 Svv' Suite/Bldg#: Project Name: arnpaSS DhGol (Name of commercial business occupp�e space. If vacant,enter Spec Space.) Planning Review Proposal: W rt1k jr- C' Or\C.A) n Verify site address/suite# exists and active in permit system. TA.River Terrace Neighborhood: ❑ Yes No M.Land Use Case#: Prn7 2-016 -01:701-1 'Plans Match Approved Land Use: '`t" Site Plan t1 Landscape Plan ❑ Other: 'Urban Forestry Plan Elevation Plan 18-Building Height: Maximum Height 25-1 I Wit Ws Actual Height +1G+ OA Conditions Met: 111 Prior to Submittal ❑ Prior to Permit Issuance l3usiness License: Exists: ❑ Yes No,applicant notified to obtain business license Public Facilities Improvement(PFI)Permit: Required: ❑ Yes,applicant was notified No Applied For: ❑ Yes ❑ No,stop intake Notes: Pcl Kylrni,+ ho+ wrta(—Ylo `lL v r» 'U.ertiS ?ro Approved by Planning: 06001,'`- Date: t I 7116 Revisions (after BuildingSubmittal on Reviewer Date y> Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved Revision 3: ❑ Approved ❑ Not Approved Building Permit Submittal Original Submittal Date: /771/ E� Site Plans: # Building Plans: # "� Building Permit#: 0 r building permit above. Workflow Routing: fanning lrYEngineering Coordinator ig-155ilding Workflow Sign-off: L�t � off for Planning(include notes from planning review) Route Application Documents: Lc /Building: original permit application,site plans,building plans, engineer and beam calculations and trust details,if applicable,etc. Notes: 1.1P VO By Permit Technician: '" Date: '/i/'r / I:\Building\Forms\BldgPennitRvw_COM_WithLandUse 060116.docx • Engineering Review ❑ Slope at building pad: CI PFI Permit#: /7i4" ❑ Conditions "Met"prior to issuance of building permit ❑ Easements (encroachments)per engineering conditions of approval and plat(not typical on SDR/CUP) ❑ Water Quality/Quantity Facility: Assess Water Quality Fee in-lieu: ❑ Yes ,_,�,/No Assess Water Quantity Fee in-lieu: Els L1 No LIDA Facility on lot: i Yes ❑ No ❑ NOT Approved by Engineering: Date Notes: Approved by Engineering: Date: /// /</7 Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved El Not Approved Revision 2: ❑ Approved El Not Approved Revision 3: ❑ Approved ❑ Not Approved Permit Coordinator Review ❑ Conditions "Met"prior to issuance of building permit ❑ Approved,NOT Released: Date: Notes: Revisions (after Building Submittal only) Revision Notice 1: Date Sent to Applicant: Revision Notice 2: Date Sent to Applicant: Re ion Notice 3: Date Sent to Applicant: fit'SDC Fees Entered: Wash Co Trans Dev Tax: Yes ❑ N/A Tigard Trans SDC: Yes El N/A Parks SDC: Yes ❑ N/A K to Issue Permit Approved by Permit Coordinator: Date: // 7"1,q I:\Building\Fonns\BldgPennitRvw_COM_WithLandUse_070915.docx 1 (-6/0:/"...-- City of Tigard COMMUNITY DEVELOPMENT DEPARTMENT ■ Tigard Triangle Plan Review Worksheet (TMU Zone Only) TIGARD Building Permit #: Site Address: r 12123 Svc/ Co ctiv, Ave. jt1 ctirko P- Project Name: CovielASE OnGo to (Owner ISA name or business namehtndJhrief project descriptor,e.g.new garage,site modifications) ZONING j$ TMU:All standards in 18.660 potentially apply. See map on last page for TMU boundary. EXEMPT FROM STANDARDS (18.660.020.B.1) Ryli ❑ Maintenance or repair lifil ❑ Accessibility(ADA)improvements ❑ Reconstruction after accidental destruction(pre-existing development that doesn't meet standards has 1 yr.to rebuild) ❑ Other: PRE-EXISTING DEVELOPMENT (18.660.050) Fl0 Pre-existing land use:May continue but not expand(18.660.050.C). ❑ Pre-existing site improvements:May continue and be modified but not go further out of conformance(18.660.050.D). la Pre-existing building:May continue and be modified subject to standards in Table 18.660.2. ❑ New building on site with pre-existing development Subject to standards in Table 18.660.3. USE(S) (18.660.060): o-FFi c,¢ CrApe t..0 J Js:Permitted ❑ Restricted:Describe how restriction met: ❑ Conditional Use:CUP# ❑ Legal pre-existing use that does not meet use standards(18.660.050.C) SITE DESIGN STANDARDS (18.660.070) 1. Building Location(18.660.070.B)—Some exceptions to max. setback for sites with existing buildings or district trees (18.660.070.B.1.b and c). Some projections allowed into min. setback(18.660.080.D). �❑ Interior Lot: 1 ft.min.and 12 ft.max.from street property line and 70%of facade within setback. Omer or Through Lot:Meets interior lot setback requirement on all street property lines;or on me street property line and bldg.located 35 ft.min.from all other street property lines. 2.Utilities and Services (18.660.070.C)—The following must be screened per#7 or located behind a building. MtAbove-ground private utilities(e.g.transformers,utility vaults)with dimensions L+W+H>36 in. L ndscaped stormwater facilities exempt. iD/Service Areas(e.g.waste and recycling containers,outdoor storage,mechanical equipment). Roof-top mechanical equipment exempt. Last Revised 04/09/18 1 of 4 I:\Community Development\ 3. Off-street Vehicle Parking(18.660.070.D)–Parking not required.The following applies to all proposed parking. ❑ Location:35 ft.min. from all street property lines and either screened per#7 or located behind a building. RA— ❑ Size/Space:7.5 ft.x 17.5 ft.min. • ❑ Vertical Clearance:7 ft.min.for parking spaces; 15 ft.min.for loading spaces. ❑ Circulation:All backing movement contained on site. ❑ Surface Material:Pavement,gravel,turf grid,or open joint pavers. ❑ Maximum Number:Use parking ratios from Table 18.310.2 to determine maximum spaces allowed. t 1 s e Parking Ratio Max. Spaces Allowed No. Spaces Proposed 4. Off-street Vehicle Parking: Landscaping(18.660.070.D.5)—The following applies if more than 10 spaces proposed. ❑ Number: 1 landscaped island w/tree at end of each row and a min.of every 5 spaces;or landscaped area running length N A of row with same or more number of trees. ❑ Size:No dimension less than 5 ft.and 90 sq.ft.min.for single-loaded row or 180 sq.ft.double-loaded row. ❑ Trees:1.5 in.min.at planting and soil volume and species per Urban Forestry Manual Section 13-2 and Appendix 3 ❑ Wheelstops required to protect landscaped areas from vehicle overhang. 5. Public Bicycle Parking(18.660.070.E)—The following applies to all required bicycle parking spaces. OLocation:Visible from sidewalk and no conflict with other improvements.May be in ROW with city engineer approval. AT ❑ Min.number for residential(not mixed-use and more than 4 units):4 spaces/120 ft.of street frontage required' .14 Min.number for non-residential and mixed-use:6 spaces/120 ft.of street frontage requiredt Street Frontage Length Parking Ratio Min. Spaces Required No. Spaces Proposed t-15 ce 12.0R. Iiiimummi I'D 6.Walls and Fences (18.660.070.F)—The following applies to walls and fences within 12 ft. of any street property line. ❑ Allowed:Retaining walls 4 ft.in height or less. 12 M ❑ Allowed:Fences and walls 3 ft.in height or less. ❑ Not Allowed:Chain link fencing and unfinished concrete blocks with any dimension equal to or greater than 15 in. 7.Street Screens (18.660.070.F.4)—The following applies to vehicle parking spaces,above-ground private utilities,and service areas not screened by a building. ❑ Material:Opaque and permanent wall,fence,or combination.Chain link fencing prohibited. 1 0 Location:Within 5 ft.of item to be screened. ❑ Height:4–6 ft.for parking area;4–8 ft.for loading area,service area,or utility. ❑ Length: 12 ft.max.where located along,and within 35 ft.of,any street property line. ❑ Screening not required where it would obstruct vehicle or pedestrian access. 8.Driveways (18.660.070.G)—The following applies to all driveways with exceptions for Dartmouth,72nd Ave,Pacific Hwy. IM0 Number of new/modified driveways:1 max.per frontage(300 ft.in length or less);1 max. for every 200 ft.of frontage (more than 300 ft.in length). , ❑ Width of new/modified driveways: 10 ft.max.for single-family;20 ft.max.for all other uses. ❑ All driveways:Reviewed by city engineer for location and adequate sight distance. t Each 120-foot length of frontage or fraction thereof triggers full requirement.Example: 125 feet of street frontage requires 12 spaces for mixed-use development. Last Revised 04/09/18 2 of 4 I:\Community Development\ 9. District Trees: Oregon White Oaks (18.660.070.H)—The following applies to trees on the District Tree Map. Ir ❑ District tree in ROW treated as street tree. 0 District tree preservation: O Tree Preservation Area: 15 ft. from tree drip line.Pedestrian facilities allowed within preservation area.Buildings, driveways,and vehicle parking and loading not allowed. O Tree Protection:5-foot metal fence on tree preservation area perimeter during all ground disturbance work. ❑ Max.Building Setback:May be increased for tree preservation per 18.660.070.B.1.c. ❑ District tree removal: ❑ Dead,dying,or diseased:TRE# ❑ Other:ADJ# TRE# BUILDING DESIGN STANDARDS (18.660.080) 10.Building Height(18.660.080.B) IVuilding Height:Max.4 and 6 stories allowed based on location.See map on last page for height areas. h/ /Story Height:Min.and max.height requirement based on story type. '1'. pc of Store Height Ground sto 12 feet min. and 25 feet max. Middle stories 14 feet max. To. sto 18 feet max. 11.Building Entries (18.660.080.C)—The following applies to all street-facing building facades. • Quantity:1 entry min.per 80 ft.of facade and per individual tenant space or residence w/o shared street-facing entry. lik If building fronts 2 or more streets,the entry requirement is met on 1 facade and all other facades that are 50 ft.or more in width. ❑ Location:20 ft.max.distance and 45-degree max.angle from street property line.90-degree max.angle for individual residential entries with porch or stoop. ❑ Grade: 1 ft.max.grade difference from sidewalk.No grade restriction for individual residential entries. ❑ Weather Protection:3 ft.min.depth;Min.width of entry;Max.6 ft.above top of entry.May project into ROW with city engineer approval.6 ft.max.projection(or min.sidewalk width,whichever is less)and 8 ft.min.clearance from sidewalk. 12.Building Projections (18.660.080.D) �/ ❑ Architectural Elements(e.g.eaves,cornices,bay windows): 1 ft.max.projection into min.building setback. 1s"tt 0 Balconies:4 ft.max.projection into ROW and 10 ft.min.clearance from sidewalk with city engineer approval. ❑ Weather Protection:6 ft.max.projection(or min.sidewalk width,whichever is less)and 8 ft.min.clearance from sidewalk with city engineer approval. 13. Building Windows (18.660.080.E)—The following applies to all street-facing building facades within 35 ft. of any street property line. ❑ Window Material:Clear glass only.No mirrored,frosted,or reflective glass for required window area. A0 Window Area:Min.area based on story type and use.Parking structures must meet area requirement,but do not have to include glass. Openings without glass may contain architectural elements that are no more than 30%sight obscuring. Type:of Stot' and L,c Min. A\indov. Area Ground Story:Mixed-Use and Non-Residential 50%of facade Upper Stories:Mixed-Use and Non-Residential 30%of facade Ground Story:Residential Only 30%of facade Upper Stories:Residential Only(does not apply to stories with sloped roofs or dormers) 15%of facade Last Revised 04/09/18 3 of 4 I:\Community Development\ City of Tigard COMMUNITY DEVELOPMENT DEPARTMENT 14 iti Tigard Triangle Plan Review Worksheet (TMU Zone Only) TIGARD Building Permit #: 011a-c) Site Address: frAft t2-1-2-3 SSW C.e criNn Ave, R,kt 1cl.tnto ft Project Name: CovtOiLCS bnc010 (Owner l.st name or business name rief project descriptor,e.g.new garage,site modifications) ZONING ig TMU:All standards in 18.660 potentially apply. See map on last page for TMU boundary. EXEMPT FROM STANDARDS (18.660.020.B.1) 0A... 0 Maintenance or repair 0 Accessibility(ADA)improvements ❑ Reconstruction after accidental destruction(pre-existing development that doesn't meet standards has 1 yr.to rebuild) ❑ Other: PRE-EXISTING DEVELOPMENT (18.660.050) ri 0 Pre-existing land use:May continue but not expand(18.660.050.C). ❑ Pre-existing site improvements:May continue and be modified but not go further out of conformance(18.660.050.D). '84 Pre-existing building:May continue and be modified subject to standards in Table 18.660.2. ❑ New building on site with pre-existing development:Subject to standards in Table 18.660.3. USE(S) (18.660.060): C}cFic¢ ChMdLtCAS la Permitted ❑ Restricted:Describe how restriction met: ❑ Conditional Use:CUP# ❑ Legal pre-existing use that does not meet use standards(18.660.050.C) SITE DESIGN STANDARDS (18.660.070) 1. Building Location(18.660.070.B)—Some exceptions to max. setback for sites with existing buildings or district trees (18.660.070.B.1.b and c). Some projections allowed into min. setback(18.660.080.D). �❑ Interior Lot: 1 ft.min.and 12 ft.max. from street property line and 70%of facade within setback. '(orner or Through Lot Meets interior lot setback requirement on all street property lines;or on one street property line and bldg.located 35 ft.min.from all other street property lines. 2.Utilities and Services (18.660.070.C)—The following must be screened per#7 or located behind a building. [4bove-ground private utilities(e.g.transformers,utility vaults)with dimensions L+W+H> 36 in. F/ L dscaped stormwater facilities exempt. Service Areas(e.g.waste and recycling containers,outdoor storage,mechanical equipment). Roof-top mechanical equipment exempt. Last Revised 04/09/18 1 of 4 I:\Community Development\ 3. Off-street Vehicle Parking(18.660.070.D)—Parking not required.The following applies to all proposed parking. N El Location:35 ft.min.from all street property lines and either screened per#7 or located behind a building. ❑ Size/Space:7.5 ft.x 17.5 ft.min. ' ❑ Vertical Clearance:7 ft.min.for parking spaces;15 ft.min.for loading spaces. O Circulation:All backing movement contained on site. ❑ Surface Material:Pavement,gravel,turf grid,or open joint pavers. ❑ Maximum Number:Use parking ratios from Table 18.310.2 to determine maximum spaces allowed. Use Parking Ratio Max. Spaces Alloyed No. Spaces Proposed 4. Off-street Vehicle Parking: Landscaping(18.660.070.D.5)—The following applies if more than 10 spaces proposed. ❑ Number: 1 landscaped island w/tree at end of each row and a min.of every 5 spaces;or landscaped area running length NA of row with same or more number of trees. ❑ Size:No dimension less than 5 ft.and 90 sq.ft.min.for single-loaded row or 180 sq.ft.double-loaded row. ❑ Trees: 1.5 in.min.at planting and soil volume and species per Urban Forestry Manual Section 13-2 and Appendix 3 ❑ Wheelstops required to protect landscaped areas from vehicle overhang. 5. Public Bicycle Parking(18.660.070.E)—The following applies to all required bicycle parking spaces. Location:Visible from sidewalk and no conflict with other improvements.May be in ROW with city engineer approval. 0 Min.number for residential(not mixed-use and more than 4 units):4 spaces/120 ft.of street frontage required' '4 Min.number for non-residential and mixed-use:6 spaces/120 ft.of street frontage required' Street Frontage Length Parking Ratio Min. Spaces Required No. Spaces Proposed rt 5 ce rwR. °I I'D 6.Walls and Fences (18.660.070.F)—The following applies to walls and fences within 12 ft. of any street property line. O Allowed:Retaining walls 4 ft.in height or less. IM ❑ Allowed:Fences and walls 3 ft.in height or less. ❑ Not Allowed:Chain link fencing and unfinished concrete blocks with any dimension equal to or greater than 15 in. 7. Street Screens (18.660.070.F.4)—The following applies to vehicle parking spaces,above-ground private utilities,and service areas not screened by a building. ❑ Material:Opaque and permanent wall,fence,or combination.Chain link fencing prohibited. C1 0 Location:Within 5 ft.of item to be screened. ❑ Height:4—6 ft. for parking area;4—8 ft.for loading area,service area,or utility. ❑ Length: 12 ft.max.where located along,and within 35 ft.of,any street property line. ❑ Screening not required where it would obstruct vehicle or pedestrian access. 8. Driveways (18.660.070.G)—The following applies to all driveways with exceptions for Dartmouth,72nd Ave,Pacific Hwy. 0 Number of new/modified driveways: 1 max.per frontage(300 ft.in length or less);1 max.for every 200 ft.of frontage (more than 300 ft.in length). , ❑ Width of new/modified driveways: 10 ft.max. for single-family;20 ft.max. for all other uses. ❑ All driveways:Reviewed by city engineer for location and adequate sight distance. 1 Each 120-foot length of frontage or fraction thereof triggers full requirement.Example:125 feet of street frontage requires 12 spaces for mixed-use development. Last Revised 04/09/18 2 of 4 I:\Community Development\ 4 9. District Trees: Oregon White Oaks (18.660.070.H)—The following applies to trees on the District Tree Map. O District tree in ROW treated as street tree. 1 k 0 District tree preservation: ❑ Tree Preservation Area: 15 ft. from tree drip line.Pedestrian facilities allowed within preservation area.Buildings, driveways,and vehicle parking and loading not allowed. ❑ Tree Protection:5-foot metal fence on tree preservation area perimeter during all ground disturbance work. ❑ Max.Building Setback:May be increased for tree preservation per 18.660.070.B.1.c. ❑ District tree removal: ❑ Dead,dying,or diseased:TRE# ❑ Other:ADJ# TRE# BUILDING DESIGN STANDARDS (18.660.080) 10. Building Height(18.660.080.B) i\ I ' uilding Height:Max.4 and 6 stories allowed based on location. See map on last page for height areas. �/ Story Height:Min.and max.height requirement based on story type. T. pe of Stor Height Ground sto 12 feet min. and 25 feet max. Middle stories 14 feet max. To. sto 18 feet max. 11. Building Entries (18.660.080.C)—The following applies to all street-facing building facades. ❑Quantity: 1 entry min.per 80 ft.of facade and per individual tenant space or residence w/o shared street-facing entry. If building fronts 2 or more streets,the entry requirement is met on 1 façade and all other facades that are 50 ft.or more in width. ❑ Location:20 ft.max.distance and 45-degree max.angle from street property line. 90-degree max.angle for individual residential entries with porch or stoop. ❑ Grade: 1 ft.max.grade difference from sidewalk.No grade restriction for individual residential entries. ❑ Weather Protection:3 ft.min.depth;Min.width of entry;Max.6 ft.above top of entry.May project into ROW with city engineer approval.6 ft.max.projection(or min.sidewalk width,whichever is less)and 8 ft.min.clearance from sidewalk. 12. Building Projections (18.660.080.D) �/ O Architectural Elements(e.g.eaves,cornices,bay windows): 1 ft.max.projection into min.building setback. Iv 0 Balconies:4 ft.max.projection into ROW and 10 ft.min.clearance from sidewalk with city engineer approval. ❑ Weather Protection:6 ft.max.projection(or min. sidewalk width,whichever is less)and 8 ft.min.clearance from sidewalk with city engineer approval. 13. Building Windows (18.660.080.E)—The following applies to all street-facing building facades within 35 ft. of any street property line. A 0 Window Material:Clear glass only.No mirrored,frosted,or reflective glass for required window area. ❑ Window Area:Min.area based on story type and use.Parking structures must meet area requirement,but do not have to include glass.Openings without glass may contain architectural elements that are no more than 30%sight obscuring. Type of Story and Use Min. Window Area Ground Story:Mixed-Use and Non-Residential 50%of facade Upper Stories:Mixed-Use and Non-Residential 30%of facade Ground Story:Residential Only 30%of facade Upper Stories:Residential Only(does not apply to stories with sloped roofs or dormers) 15%of facade Last Revised 04/09/18 3 of 4 I:\Community Development\ City of Tigard Tel: 503.718.2439 Location: Inspection Date: 12123 SW 69TH AVE, TIGARD, OR, 97223 Record Type: Record ID: Commercial - Building BUP2019-00003 Inspection Type: Inspector: 299 Final inspection Jeff Grove Result: FA I L Comments: Fire life safety not complete at this time for public access Ok for TCO only for installation of equipment from owner Violation Summary: Inspector Contractor