Loading...
Specifications (21) V\(\ -\-- -0c--i- cWti t LY 'S SW \,Oc c.K-k- St Project: page Location:Footing"B" Keith A Kudrna Footing `+ Suntel Design 16865 Boones Ferry Rd of [2012 International Building Code(2012 NDS)] a •`^^ Lake Oswego,Oregon 97035 Footing Size:3.167 FT x 3.167 FT x 12.00 IN w Reinforcement:#4 Bars @ 7.00 IN.O.C. E/W/(5)min. StruCalc Version 9.0.1.7 9/17/2015 1:14:49 PM Section Footing Design Adequate FOOTING PROPERTIES LOADING DIAGRAM Allowable Soil Bearing Pressure: Qs= 1500 psf Concrete Compressive Strength: Pc= 2500 psi Reinforcing Steel Yield Strength: Fy= 40000 psir+ q Concrete Reinforcement Cover: c= 3 in +'7 �'` FOOTING SIZE Width: W= 3.17 ft FEB 1 2017 Length: L= 3.17 ft Depth: Depth= 12 in ell Y '-t j ,'a f k l Effective Depth to Top Layer of Steel: d= 8.25 in t°.{,=I 1, r i,r4-..,,11,..., ,I COLUMN AND BASEPLATE SIZE Column Type: Wood Column Width: m= 4 in Column Depth: n= 4 in FOOTING CALCULATIONS Bearing Calculations: Ultimate Bearing Pressure: Qu= 1246 psf tea'" Effective Allowable Soil Bearing Pressure: Qe= 1350 psf — I I Required Footing Area: Areq= 9.26 sf Area Provided: A= 10.03 sf Baseplate Bearing: Bearing Required: Bear= 17500 lb 12 in Allowable Bearing: Bear-A= 44200 lb0 0 0 Cl Beam Shear Calculations(One Way Shear): T Beam Shear: Vu1 = 4951 lb 3 in Allowable Beam Shear: Vc1 = 23515 lb 3.167 ft i y Punching Shear Calculations(Two Way Shear): Critical Perimeter: Bo= 49 in Punching Shear: Vu2= 15682 lb FOOTING LOADING Allowable Punching Shear(ACI 11-35): vc2-a= 90956 lb Live Load: PL= 0 lb Allowable Punching Shear(ACI 11-36): vc2-b= 132413 lb Dead Load: PD= 12500 lb Allowable Punching Shear(ACI 11-37): vc2-c= 60638 lb Total Load: PT= 12500 lb Controlling Allowable Punching Shear: vc2= 60638 lb Ultimate Factored Load: Pu= 17500 lb Bending Calculations: Weight to resist uplift w/1.5 F.S.: U.R.= 970 lb Factored Moment: Mu= 83134 in-lb Nominal Moment Strength: Mn= 282847 in-lb Reinforcement Calculations: Concrete Compressive Block Depth: a= 0.49 in Steel Required Based on Moment: As(1)= 0.28 in2 Min.Code Req'd Reinf.Shrink./Temp. (ACI-10.5.4):As(2)= 0.91 in2 Controlling Reinforcing Steel: As-reqd= 0.91 in2 Selected Reinforcement: #4's @ 7.0 in.o.c.e/w(5)Min. Reinforcement Area Provided: As= 0.98 in2 Development Length Calculations: Development Length Required: Ld= 15 in Development Length Supplied: Ld-sup= 16 in Note: Plain concrete adequate for bending, therefore adequate development length not required. • Project: 11. NiNt!" Page Rte— Keith A Kudrna rr-Location:Footing"B" . Suntel Design Footing 16865 Boones Ferry Rd of [2012 International Building Code(2012 NDS)] :4 -. Lake Oswego,Oregon 97035 Footing Size:3.167 FT x 3.167 FT x 12.00 IN Reinforcement:#4 Bars @ 7.00 IN.O.C. E/W/(5)min. StruCalc Version 9.0.1,7 9/17/2015 1:14:49 PM Section Footing Design Adequate FOOTING PROPERTIES LOADING DIAGRAM Allowable Soil Bearing Pressure: Qs= 1500 psf Concrete Compressive Strength: F'c= 2500 psi Reinforcing Steel Yield Strength: Fy= 40000 psi Concrete Reinforcement Cover: c= 3 in FOOTING SIZE Width: W= 3.17 ft Length: L= 3.17 ft Depth: Depth= 12 in Effective Depth to Top Layer of Steel: d= 8.25 in COLUMN AND BASEPLATE SIZE Column Type: Wood Column Width: m= 4 in Column Depth: n= 4 in FOOTING CALCULATIONS Bearing Calculations: Ultimate Bearing Pressure: Qu= 1246 psf 1----4 in—I Effective Allowable Soil Bearing Pressure: Qe= 1350 psf — I I Required Footing Area: Areq= 9.26 sf Area Provided: A= 10.03 sf Baseplate Bearing: Bearing Required: Bear= 17500 lb 12 in Allowable Bearing: Bear-A= 44200 lb Beam Shear Calculations(One Way Shear): T Beam Shear: Vu1 = 4951 lb 3 in Allowable Beam Shear: Vc1 = 23515 lb Punching Shear Calculations(Two Way Shear): 3.167 ft Critical Perimeter: Bo= 49 in Punching Shear: Vu2= 15682 lb FOOTING LOADING Allowable Punching Shear(ACI 11-35: vc2-a_ 90956 Ib Live Load: PL= 0 lb Allowable Punching Shear(ACI 11-36): vc2-b= 132413 lb Dead Load: PD= 12500 lb Allowable Punching Shear(ACI 11-37): vc2-c= 60638 lb Total Load: PT= 12500 lb Controlling Allowable Punching Shear: vc2= 60638 lb Ultimate Factored Load: Pu= 17500 lb Bending Calculations: Weight to resist uplift w/1.5 F.S.: U.R.= 970 lb Factored Moment: Mu= 83134 in-lb Nominal Moment Strength: Mn= 282847 in-lb Reinforcement Calculations: Concrete Compressive Block Depth: a= 0.49 in Steel Required Based on Moment: As(1)= 0.28 in2 Min.Code Req'd Reinf.Shrink./Temp. (ACI-10.5.4):As(2)= 0.91 in2 Controlling Reinforcing Steel: As-reqd= 0.91 in2 Selected Reinforcement: #4's @ 7.0 in.o.c.e/w(5)Min. Reinforcement Area Provided: As= 0.98 in2 Development Length Calculations: Development Length Required: Ld= 15 in Development Length Supplied: Ld-sup= 16 in Note:Plain concrete adequate for bending, therefore adequate development length not required. I i Project:Chehalem B_Biggi_Lot 4 Oak Woods Beams I ,° Page Judith Souers Location: Beam Nr.01 -Cant Beam at Garage Clg j%* Suntel Design / Multi-Loaded Multi-Span Beam 16865 Boones Ferry Rd Suite 201 of [2015 International Building Code(2012 NDS)] >r Lake Oswego,OR 97035 (3)1.75 IN x 11.25 IN x 12.33 FT(9.3+3) �` 1.9E Microllam-iLevel Trus Joist StruCalc Version 9.0.2.5 12/27/2016 4:43:07 PM Section Adequate By:24.4% Controlling Factor:Shear CAUTIONS *Laminations are to be fully connected to provide uniform transfer of loads to all members DEFLECTIONS Center Right LOADING DIAGRAM Live Load -0.05 IN L/2343 0.09 IN 2L/772 Dead Load -0.03 in 0.07 in . ,e" g 4 , Total Load -0.08 IN L/1422 0.16 IN 2L/456 Live Load Deflection Criteria:L/360 Total Load Deflection Criteria:L/240 FES' 1 2017 i REACTIONS A B Live Load 187 lb 6075 lb ;t i Y b / (-t z'1F) Dead Load -312 lb 4385 lb f� � Total Load -125 lb 10460 lb no Uplift(1.5 F.S) -940 lb 0 lb Bearing Length 0.00 in 2.66 in W IN '444i 4j.,X ) .1C.,` '''" .' `r:.t f ` " t? fe,c„,..7,„,,,,L ' ... BEAM DATA Center Right Span Length 9.33 ft 3 ft 9.33 ft 3 ft1 Unbraced Length-Top 0 ft 0 ft Unbraced Length-Bottom 9.33 ft 3 ft Live Load Duration Factor 1.00 Notch Depth 0.00 UNIFORM LOADS Center Right Uniform Live Load 40 plf 40 plf MATERIAL PROPERTIES Uniform Dead Load 15 plf 15 plf 1.9E Microllam-iLevel Trus Joist Beam Self Weight 18 plf 18 plf Base Values Adjusted Total Uniform Load 73 plf 73 plf Bending Stress: Fb= 2600 psi Fb'= 2591 psi POINT LOADS-RIGHT SPAN Cd=1.00 C1=0.99 CF=1.01 Load Number One Shear Stress: Fv= 285 psi Fv'= 285 psi Live Load 4600 lb Cd=1.00 Dead Load 3100 lb Modulus of Elasticity: E= 1900 ksi E'= 1900 ksi Location 1 ft Comp. L to Grain: Fc-1= 750 psi Fc--L'= 750 psi TRAPEZOIDAL LOADS-RIGHT SPAN Controlling Moment: -10231 ft-lb Load Number One Over right support of span 2(Center Span) Left Live Load 270 plf Created by combining all dead loads and live loads on span(s)3 Left Dead Load 280 plf Controlling Shear: 9020 lb Right Live Load 270 plf At left support of span 3(Right Span) Right Dead Load 280 plf Created by combining all dead loads and live loads on span(s)2,3 Load Start 1 ft Load End 3 ft Comparisons with required sections: Req'd Provided Load Length 2 ft Section Modulus: 47.38 in3 110.74 in3 Area(Shear): 47.48 in2 59.06 in2 Moment of Inertia(deflection): 328.56 in4 622.92 in4 Moment: -10231 ft-lb 23912 ft-lb Shear: 9020 lb 11222 lb NOTES Project:Chehalem B_Biggi_Lot 4 Oak Woods_Beams ‘-, 1 page .�., , Judith th Sowers / Location:Beam Nr.02 garage door header (- �'� `Suntel Design Multi-Loaded Multi-Span Beam 16865 Boones Ferry Rd Suite 201 or [2015 International Building Code(2012 NDS)] _` w> Lake Oswego,OR 97035 5.5 IN x 24.0 IN x 16.5 FT 24F-V4-Visually Graded Western Species-Dry Use StruCalc Version 9.0.2.5 12/27/2016 4:43:07 PM Section Adequate By:9.4% Controlling Factor:Shear DEFLECTIONS Center LOADING DIAGRAM Live Load 0.16 IN L/1234 Dead Load 0.12 in Total Load 0.28 IN L/701 Live Load Deflection Criteria: U480 Total Load Deflection Criteria: L/360 REACTIONS A Live Load 6894 lb 11051 lb Dead Load 5340 lb 8246 lb Total Load 12234 lb 19297 lb Bearing Length 3.42 in 5.40 in .. BEAM DATA Center Span Length 16.5 ft Unbraced Length-Top 1.33 ft Unbraced Length-Bottom 16.5 ft TRI Live Load Duration Factor 1.00 Camber Adj. Factor 1.5 UNIFORM LOADS Center Camber Required 0.18 Uniform Live Load 0 plf Notch Depth 0.00 Uniform Dead Load 0 plf MATERIAL PROPERTIES Beam Self Weight 29 plf 24F-V4-Visually Graded Western Species Total Uniform Load 29 plf Base Values Adjusted POINT LOADS-CENTER SPAN Bending Stress: Fb= 2400 psi Controlled by: Load Number One Fb_cmpr= 1850 psi Fb'= 2278 psi Live Load 6100 lb Cd=1.00 CI=1.00 Cv=0.95 Dead Load 4400 lb Shear Stress: Fv= 240 psi Fv'= 240 psi Location 12.25 ft Cd=1.00 Modulus of Elasticity: E= 1800 ksi E'= 1800 ksi TRAPEZOIDAL LOADS-CENTER SPAN Comp.-I-to Grain: Fc- = 650 psi Fc--- = 650 psi Load Number One Two Left Live Load 620 plf 1000 plf Controlling Moment: 67197 ft-lb Left Dead Load 465 plf 710 plf 11.06 Ft from left support of span 2(Center Span) Right Live Load 620 plf 1000 plf Created by combining all dead loads and live loads on span(s)2 Right Dead Load 465 plf 710 plf Controlling Shear: -19297 lb Load Start 0 ft 12.25 ft 16.0 Ft from left support of span 2(Center Span) Load End 12.25 ft 16.5 ft Created by combining all dead loads and live loads on span(s)2 Load Length 12.25 ft 4.25 ft Comparisons with required sections: Read Provided Section Modulus: 354.01 in3 528 in3 Area(Shear): 120.61 in2 132 in2 Moment of Inertia(deflection): 3252.61 in4 6336 in4 Moment: 67197 ft-lb 100223 ft-lb Shear: -19297 lb 21120 lb NOTES Project:Chehalem B_Biggi_Lot 4 Oak Woods Beams ;, page �-- 71Judith Sowers / Location:Beam Nr.03 at garage porch � ' Suntel Design Multi-Loaded Multi-Span Beam 16865 Boones Ferry Rd Suite 201 of [2015 International Building Code(2012 NDS)] "`'i ---ft*Lake Oswego,OR 97035 5.5 IN x 15.0 IN x 22.5 FT 24F-V4-Visually Graded Western Species-Wet Use StruCalc Version 9.0.2.5 12/27/2016 4:43:08 PM Section Adequate By: 142.3% Controlling Factor: Deflection DEFLECTIONS Center LOADING DIAGRAM Live Load 0.25 IN L/1072 Dead Load 0.21 in Total Load 0.46 IN L/581 Live Load Deflection Criteria:L/360 Total Load Deflection Criteria:L/240 REACTIONS A B Live Load 1069 lb 1346 lb Dead Load 914 lb 1099 lb Total Load 1983 lb 2445 lb Bearing Length 1.05 in 1.29 in TR1 TR2 BEAM DATA Center Span Length 22.5 ft Unbraced Length-Top 2 ft Unbraced Length-Bottom 22.5 ft Live Load Duration Factor 1.00 Camber Adj.Factor 1.5 UNIFORM LOADS Center Camber Required 0.32 Uniform Live Load 0 plf Notch Depth 0.00 Uniform Dead Load 0 plf MATERIAL PROPERTIES Beam Self Weight 18 plf 24F-V4-Visually Graded Western Species Total Uniform Load 18 plf Base Values Adjusted TRAPEZOIDAL LOADS-CENTER SPAN Bending Stress: Fb= 2400 psi Controlled by: Load Number One Two Fb_cmpr= 1850 psi Fb'= 1852 psi Left Live Load 90 plf 150 plf Cm=0.80 CI=1.00 Cv=0.96 Left Dead Load 60 plf 100 plf Shear Stress: Fv= 240 psi Fv'= 210 psi Right Live Load 90 plf 150 plf Cd=1.00 Cm=0.88 Right Dead Load 60 plf 100 plf Modulus of Elasticity: E= 1800 ksi E'= 1499 ksi Load Start 0 ft 16 ft Cm=0.83 Load End 16 ft 22.5 ft Comp.-L to Grain: Fc-1= 650 psi Fc--- = 345 psi Load Length 16 ft 6.5 ft Cm=0.53 Controlling Moment: 11705 ft-lb 11.7 Ft from left support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Controlling Shear: -2445 lb 22.0 Ft from left support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Comparisons with required sections: Req'd Provided Section Modulus: 75.86 in3 206.25 in3 Area(Shear): 17.46 in2 82.5 in2 Moment of Inertia(deflection): 638.53 in4 1546.88 in4 Moment: 11705 ft-lb 31824 ft-lb Shear: -2445 lb 11550 lb NOTES page Project:Chehalem B_Biggi_Lot 4 Oak Woods_Beams Location:Beam Nr.04 front porch beam Judith Souers Roof Beam Suntel Design / 16865 Boones Ferry Rd Suite 201 of - [2015 International Building Code(2012 NDS)] 'Y- Lake Oswego,OR 97035 3.51N x 13.25 IN x 10.0 FT #2-Douglas-Fir-Larch-Dry Use StruCalc Version 9.0.2.5 12/27/2016 4:43:08 PM Section Adequate By:878.3% Controlling Factor:Moment DEFLECTIONS Center LOADING DIAGRAM Live Load 0.01 IN UMAX Dead Load 0.01 in Total Load 0.01 IN L/8051 Live Load Deflection Criteria:U360 Total Load Deflection Criteria: L/240 REACTIONS A_ Live Load 188 lb 188 lb Dead Load 172 lb 172 lb Total Load 360 lb 360 lb Bearing Length 0.16 in 0.16 in BEAM DATA ... . ..... ....._ ..:. , n,. . . .............. Span Length 10 ft Unbraced Length-Top 2 ft loft Unbraced Length-Bottom 0 ft Roof Pitch 5 :12 Roof Duration Factor 1.15 ROOF LOADING MATERIAL PROPERTIES Side One: #2-Douglas-Fir-Larch Roof Live Load: LL= 25 psf Base Values Adjusted Roof Dead Load: DL= 15 psf Bending Stress: Fb= 900 psi Fb'= 1031 psi Tributary Width: TW= 0.5 ft Cd=1.15 CI=1.00 CF=1.00 Side Two: Shear Stress: Fv= 180 psi Fv'= 207 psi Roof Live Load: LL= 25 psf Cd=1.15 Roof Dead Load: DL= 15 psf Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi Tributary Width: TW= 1 ft Comp. L to Grain: Fc- L= 625 psi Fc- L'= 625 psi Wall Load: WALL= 0 Controlling Moment: 899 ft-lb plf 5.0 ft from left support SLOPE/PITCH ADJUSTED LENGTHS AND LOADS Created by combining all dead and live loads. Adjusted Beam Length: Ladj= 10 ft Controlling Shear: -360 lb Beam Self Weight: BSW= 10 plf At support. Beam Uniform Live Load: wL= 38 plf Created by combining all dead and live loads. Beam Uniform Dead Load: wD_adj= 34 plf Comparisons with required sections: Rea'd Provided Total Uniform Load: wT= 72 plf Section Modulus: 10.47 in3 102.41 in3 Area(Shear): 2.61 in2 46.38 in2 Moment of Inertia(deflection): 20.23 in4 678.48 in4 Moment: 899 ft-lb 8795 ft-lb Shear: -360 lb 6400 lb NOTES . I Project:Chehalem B_Biggi_Lot 4 Oak Woods_Beams ipage Judth Souers Location: Beam Nr.05 entry ceil beam I. • Suntel Design Combination Roof And Floor Beam 16865 Boones Ferry Rd Suite 201 of - [2015 International Building Code(2012 NDS)] '. ms...µ-- ,Lake Oswego,OR 97035 (2) 1.5 IN x 11.25 IN x 5.5 FT #2-Douglas-Fir-Larch-Dry Use StruCalc Version 9.0.2.5 12/27/2016 4:43:08 PM Section Adequate By:33.2% Controlling Factor:Moment CAUTIONS *Laminations are to be fully connected to provide uniform transfer of loads to all members DEFLECTIONS Center LOADING DIAGRAM Live Load 0.02 IN L/2809 Dead Load 0.02 in Total Load 0.04 IN L/1691 Live Load Deflection Criteria: L/360 Total Load Deflection Criteria: L/240 REACTIONS A B Live Load 1788 lb 1788 lb Dead Load 1182 lb 1182 lb Total Load 2970 lb 2970 lb Bearing Length 1.58 in 1.58 in BEAM DATA Center w Span Length 5.5 ft Unbraced Length-Top 1.33 ft Roof Pitch 0 :12 lilliti Floor Duration Factor 1.00 Roof Duration Factor 1.15 Notch Depth 0.00 ROOF LOADING Side 1 Side 2 MATERIAL PROPERTIES Roof Live Load RLL= 30 psf 30 psf #2-Douglas-Fir-Larch Roof Dead Load RDL= 15 psf 15 psf Base Values Adjusted Roof Tributary Width RTW= 1 ft 20 ft Bending Stress: Fb= 900 psi Fb'= 1032 psi Cd=1.15 CI=1.00 CF=1.00 FLOOR LOADING Shear Stress: Fv= 180 psi Fv'=— 207 psi Side 1 Side 2 Cd=1.15 Floor Live Load FLL= 40 psf 40 psf Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi Floor Dead Load FDL= 15 psf 15 psf Comp.--to Grain: Fc-1= 625 psi Fc-1'= 625 psi Floor Tributary Width FTW= 0 ft 0.5 ft Controlling Moment: 4083 ft-lb Wall Load WALL= 100 plf 2.75 ft from left support BEAM LOADING Created by combining all dead and live loads. Roof Uniform Live Load: wL-roof= 630 plf Controlling Shear: -2969 lb Roof Uniform Dead Load: wD-roof= 315 plf At support. Floor Uniform Live Load: wL-floor= 20 plf Created by combining all dead and live loads. Floor Uniform Dead Load: wD-floor= 8 plf Beam Self Weight: BSW= 7 plf Comparisons with required sections: Read Provided Combined Uniform Live Load: wL= 650 plf Section Modulus: 47.49 in3 63.28 in3 Combined Uniform Dead Load: wD= 430 plf Area(Shear): 21.52 in2 33.75 int Combined Uniform Total Load: wT= 1080 plf Moment of Inertia(deflection): 50.52 in4 355.96 in4 Controlling Total Design Load: wT-cont= 1080 plf Moment: 4083 ft-lb 5440 ft-lb Shear: -2969 lb 4658 lb NOTES • Project:Chehalem B_Biggi_Lot 4 Oak Woods_Beams `` ' „Judith Souers page - Location:Beam Nr.06 at garage ceiling 1> Suntel Design Multi-Loaded Multi-Span Beam £ " r 16865 Boones Ferry Rd Suite 201 of [2015 International Building Code(2012 NDS)] "`` - Lake Oswego,OR 97035 5.5 IN x 21.0 IN x 22.0 FT 24F-V4-Visually Graded Western Species-Dry Use StruCalc Version 9.0.2.5 12/27/2016 4:43:08 PM Section Adequate By: 105.4% Controlling Factor:Moment DEFLECTIONS Center LOADING DIAGRAM Live Load 0.33 IN L/801 Dead Load 0.09 in Total Load 0.42 IN L/631 Live Load Deflection Criteria: L/360 Total Load Deflection Criteria: L/240 REACTIONS A Live Load 5050 lb 5329 lb Dead Load 1402 lb 1425 lb Total Load 6452 lb 6754 lb TR1 TR2 Bearing Length 1.80 in 1.89 in BEAM DATA Center w Span Length 22 ft rg Unbraced Length-Top 1.33 ft Unbraced Length-Bottom 22 ft Live Load Duration Factor 1.00 Camber Adj. Factor 1 UNIFORM LOADS Center Camber Required 0.09 Uniform Live Load 240 plf Notch Depth 0.00 Uniform Dead Load 90 plf MATERIAL PROPERTIES Beam Self Weight 25 plf 24F-V4-Visually Graded Western Species Total Uniform Load 355 plf Base Values Adjusted TRAPEZOIDAL LOADS-CENTER SPAN Bending Stress: Fb= 2400 psi Controlled by: Load Number One Fb_cmpr= 1850 psi Fb'= 2243 psi Left Live Load 190 plf 250 plf Cd=1.00 CI=1.00 Cv=0.93 Left Dead Load 10 plf 15 plf Shear Stress: Fv= 265 psi Fv'= 265 psi Right Live Load 190 plf 250 plf Cd=1.00 Right Dead Load 10 plf 15 plf Modulus of Elasticity: E= 1800 ksi E'= 1800 ksi Load Start 0 ft 6.67 ft Comp.1-to Grain: Fc-L= 650 psi Fc- L'= 650 psi Load End 6.67 ft 22 ft Controlling Moment: 36787 ft-lb Load Length 6.67 ft 15.33 ft 11.0 Ft from left support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Controlling Shear: -6755 lb At right support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Comparisons with required sections: Rea'd Provided Section Modulus: 196.81 in3 404.25 in3 Area(Shear): 38.23 in2 115.5 in2 Moment of Inertia(deflection): 1906.51 in4 4244.63 in4 Moment: 36787 ft-lb 75559 ft-lb Shear: -6755 lb 20405 lb NOTES page Project:Chehalem B_Biggi_Lot 4 Oak Woods_Beams � Judith Souers - Location: Beam Nr.07 at grt rm ceil. "t; '� Suntel Design Uniformly Loaded Floor Beam 16865 Boones Ferry Rd Suite 201 of - [2015 International Building Code(2012 NDS)] (2) 1.5 IN x 11.25 IN x 6.25 FT Lake Oswego,OR 97035 #2-Douglas-Fir-Larch-Dry Use StruCalc Version 9.0.2.5 12/27/2016 4:43:08 PM Section Adequate By: 15.5% Controlling Factor:Moment CAUTIONS *Laminations are to be fully connected to provide uniform transfer of loads to all members DEFLECTIONS Center LOADING DIAGRAM Live Load 0.04 IN L/1944 Dead Load 0.01 in Total Load 0.05 IN L/1483 Live Load Deflection Criteria: L/360 Total Load Deflection Criteria: L/240 REACTIONS A Live Load 2000 lb 2000 lb Dead Load 623 lb 623 lb Total Load 2623 lb 2623 lb Bearing Length 1.40 in 1.40 in BEAM DATA Center Span Length 6.25 ft Unbraced Length-Top 1.33 ft 6.25 ft Floor Duration Factor 1.00 Notch Depth 0.00 MATERIAL PROPERTIES FLOOR LOADING #2-Douglas-Fir-Larch Side 1 Side 2 Base Values Adjusted Floor Live Load FLL= 40 psf 40 psf Bending Stress: Fb= 900 psi Fb'= 898 psi Floor Dead Load FDL= 12 psf 12 psf Cd=1.00 CI=1.00 CF=1.00 Floor Tributary Width FTW= 8 ft 8 ft Shear Stress: Fv= 180 psi Fv'= 180 psi Cd=1.00 Wall Load WALL= 0 plf Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi BEAM LOADING Comp.-I-to Grain: Fc-1= 625 psi Fc- = 625 psi Beam Total Live Load: wL= 640 plf Controlling Moment: 4098 ft Ib Beam Total Dead Load: wD= 192 plf 3.125 ft from left support Beam Self Weight: BSW= 7 plf Total Maximum Load: wT= 839 plf Created by combining all dead and live loads. Controlling Shear: -2623 lb At support. Created by combining all dead and live loads. Comparisons with required sections: Rea'd Provided Section Modulus: 54.79 in3 63.28 in3 Area(Shear): 21.86 in2 33.75 in2 Moment of Inertia(deflection): 65.91 in4 355.96 in4 Moment: 4098 ft-lb 4733 ft-lb Shear: -2623 lb 4050 lb NOTES • - Project:Chehalem B_Biggi_Lot 4 Oak Woods_Beams .,.Judith Souers page _ Location: Beam Nr.08 Ceiling Beam at Nook I-,- * Suntel Design / Multi-Loaded Multi-Span Beam 16865 Boones Ferry Rd Suite 201 of - [2015 International Building Code(2012 NDS)] Lake Oswego,OR 97035 5.5 IN x 16.5 IN x 13.5 FT 24F-V4-Visually Graded Western Species-Dry Use StruCalc Version 9.0.2.5 12/27/2016 4:43:09 PM Section Adequate By:29.7% Controlling Factor:Moment DEFLECTIONS Center LOADING DIAGRAM Live Load 0.20 IN L/805 Dead Load 0.14 in Total Load 0.34 IN L/475 Live Load Deflection Criteria:L/360 Total Load Deflection Criteria: L/240 REACTIONS A Live Load 6081 lb 6561 lb Dead Load 4258 lb 4559 lb Total Load 10339 lb 11120 lb trt1' Bearing Length 2.89 in 3.11 in az BEAM DATA Center W Span Length 13.5 ft Unbraced Length-Top 1.33 ft Unbraced Length-Bottom 13.5 ft111111111, Live Load Duration Factor 1.00 Camber Adj. Factor 1 UNIFORM LOADS Center Camber Required 0.14 Uniform Live Load 320 plf Notch Depth 0.00 Uniform Dead Load 220 plf MATERIAL PROPERTIES Beam Self Weight 20 plf 24F-V4-Visually Graded Western Species Total Uniform Load 560 plf Base Values Adjusted POINT LOADS-CENTER SPAN Bending Stress: Fb= 2400 psi Controlled by: Load Number One Fb_cmpr= 1850 psi Fb'= 2395 psi Live Load 1600 lb Cd=1.00 CI=1.00 Dead Load 1100 lb Shear Stress: Fv= 265 psi Fv'= 265 psi Location 2.83 ft Cd=1.00 Modulus of Elasticity: E= 1800 ksi E'= 1800 ksi TRAPEZOIDAL LOADS-CENTER SPAN Comp.1 to Grain: Fc-1= 650 psi Fc-1'= 650 psi Load Number ne Left Live Load 630 plf Controlling Moment: 38408 ft-lb Left Dead Load 420 plf 6.61 Ft from left support of span 2(Center Span) Right Live Load 630 plf Created by combining all dead loads and live loads on span(s)2 Right Dead Load 420 plf Controlling Shear: -11120 lb Load Start 2.83 ft 14.0 Ft from left support of span 2(Center Span) Load End 13.5 ft Created by combining all dead loads and live loads on span(s)2 Load Length 10.67 ft Comparisons with required sections: Read Provided Section Modulus: 192.42 in3 249.56 in3 Area(Shear): 62.94 in2 90.75 in2 Moment of Inertia(deflection): 1040.35 in4 2058.89 in4 Moment: 38408 ft-lb 49815 ft-Ib Shear: -11120 lb 16033 lb NOTES ti page Project:Chehalem B_Biggi_Lot 4 Oak Woods Beams ik. ', ! 70 Judith Souers - Location: Beam Nr.09-Header at Basment Slider —" * Suntel Design / Multi-Loaded Multi-Span Beam 16865 Boones Ferry Rd Suite 201 of [2015 International Building Code(2012 NDS)] Lake Oswego,OR 97035 5.5 IN x 10.5 IN x 6.5 FT L^' 24F-V4-Visually Graded Western Species-Dry Use StruCalc Version 9.0.2.5 12/27/2016 4:43:09 PM Section Adequate By:24.6% Controlling Factor:Shear DEFLECTIONS Center LOADING DIAGRAM Live Load 0.06 IN L/1415 Dead Load 0.04 in Total Load 0.09 IN L/860 Live Load Deflection Criteria: L/360 Total Load Deflection Criteria: L/240 REACTIONS A Live Load 5013 lb 3507 lb Dead Load 3177 lb 2274 lb Total Load 8190 lb 5781 lb 2 Bearing Length 2.29 in 1.62 in BEAM DATA Center w Span Length 6.5 ft Unbraced Length-Top 1.33 ft 111111111., Unbraced Length-Bottom 6.5 ft Live Load Duration Factor 1.00 Camber Adj.Factor 1 UNIFORM LOADS Center Camber Required 0.04 Uniform Live Load 480 plf Notch Depth 0.00 Uniform Dead Load 180 plf MATERIAL PROPERTIES Beam Self Weight 13 plf 24F-V4-Visually Graded Western Species Total Uniform Load 673 plf Base Values Adjusted POINT LOADS-CENTER SPAN Bending Stress: Fb= 2400 psi Controlled by: Load Number One Two Fb_cmpr= 1850 psi Fb'= 2397 psi Live Load 3800 lb 1600 lb Cd=1.00 C1=1.00 Dead Load 2700 lb 1500 lb Shear Stress: Fv= 265 psi Fv'= 265 psi Location 1.33 ft 4.75 ft Cd=1.00 Modulus of Elasticity: E= 1800 ksi E'= 1800 ksi Comp.1 to Grain: Fc-L= 650 psi Fc--- = 650 psi Controlling Moment: 10769 ft-lb 2.53 Ft from left support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Controlling Shear: 8190 lb At left support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Comparisons with required sections: Req'd Provided Section Modulus: 53.91 in3 101.06 in3 Area(Shear): 46.36 in2 57.75 in2 Moment of Inertia(deflection): 148.15 in4 530.58 in4 Moment: 10769 ft-lb 20188 ft-lb Shear: 8190 lb 10203 lb NOTES Project:Chehalem B_Biggi_Lot 4 Oak Woods_Beams \ tr Page IF Judith Souers Location: Beam Nr. 10 carrier at bm 3Suntel Des � ' Design Multi-Loaded Multi-Span Beam 16865 Boones Ferry Rd Suite 201 of [2015 International Building Code(2012 NDS)] h£ Lake Oswego,OR 97035 3.5 IN x 13.25 IN x 4.5 FT #2-Douglas-Fir-Larch-Dry Use StruCalc Version 9.0.2,5 12/27/2016 4:43:09 PM Section Adequate By: 165.3% Controlling Factor:Shear DEFLECTIONS Center LOADING DIAGRAM Live Load 0.00 IN L/MAX Dead Load 0.00 in Total Load 0.01 IN L/6687 Live Load Deflection Criteria: L/360 Total Load Deflection Criteria:L/240 REACTIONS A_ B Live Load 772 lb 1138 lb Dead Load 626 lb 959 lb Total Load 1398 lb 2097 lb Bearing Length 0.64 in 0.96 in BEAM DATA Center w Span Length 4.5 ft Unbraced Length-Top 0 ft 4.5 ft B Unbraced Length-Bottom 4.5 ft Live Load Duration Factor 1.00 Notch Depth 0.00 UNIFORM LOADS Center MATERIAL PROPERTIES Uniform Live Load 180 plf #2-Douglas-Fir-Larch Uniform Dead Load 120 plf Base Values Adjusted Beam Self Weight 10 plf Bending Stress: Fb= 900 psi Fb'= 900 psi Total Uniform Load 310 plf Cd=1.00 CF=1.00 POINT LOADS-CENTER SPAN Shear Stress: Fv= 180 psi Fv'= 180 psi Load Number One Cd=1.00 Live Load 1100 lb Modulus of Elasticity: E= 1600 ksi E= 1600 ksi Dead Load 1000 lb Comp. L to Grain: Fc- L= 625 psi Fc--- = 625 psi Location 3 ft Controlling Moment: 2783 ft-lb 2.97 Ft from left support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Controlling Shear: -2098 lb 5.0 Ft from left support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Comparisons with required sections: Req'd Provided Section Modulus: 37.11 in3 102.41 in3 Area(Shear): 17.48 in2 46.38 in2 Moment of Inertia(deflection): 24.35 in4 678.48 in4 Moment: 2783 ft-lb 7681 ft-lb Shear: -2098 lb 5565 lb NOTES • Project:Chehalem B_Biggi_Lot 4 Oak Woods_Beams ; # vase Location:Beam Nr. 11-Deck Beam Judith Sowers / • Suntel Design R Uniformly Loaded Floor Beam 16865 Boones Ferry Rd Suite 201 of [2015 International Building Code(2012 NDS)] Lake Oswego,OR 97035 3.5 IN x 7.25 IN x 9.0 FT #2-Douglas-Fir-Larch-Dry Use StruCalc Version 9.0.2.5 12/27/2016 4:43:09 PM Section Adequate By:30.6% Controlling Factor:Moment DEFLECTIONS Center LOADING DIAGRAM Live Load 0.13 IN L/813 Dead Load 0.05 in Total Load 0.19 IN L/577 Live Load Deflection Criteria: L/360 Total Load Deflection Criteria: L/240 REACTIONS A Live Load 720 lb 720 lb Dead Load 295 lb 295 lb Total Load 1015 lb 1015 lb Bearing Length 0.46 in 0.46 in BEAM DATA Center Span Length 9 ft L:.......tV—.1V0../1,LI I,. .:.`.X�:'I W.:....1.� d/I'.ftr141 Unbraced Length-Top 2 ft 9n Floor Duration Factor 1.00 Notch Depth 0.00 MATERIAL PROPERTIES FLOOR LOADING #2-Douglas-Fir-Larch Side 1 Side 2 Base Values Adjusted Floor Live Load FLL= 40 psf 40 psf Bending Stress: Fb= 900 psi Fb'= 1167 psi Floor Dead Load FDL= 15 psf 15 psf Cd=1.00 C/=1.00 CF=1.30 Floor Tributary Width FTW= 4 ft 0 ft Shear Stress: Fv= 180 psi Fv'= 180 psi Cd=1.00 Wall Load WALL= 0 plf Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi BEAM LOADING Min.Mod.of Elasticity: E_m 580 ksi E_min = 580 ksi Beam Total Live Load: wL= 160 plf Comp. to Grain: Fc- = 625 psi Fc- = 625 psi Beam Total Dead Load: wD= 60 plf Controlling Moment: 2283 ft-lb Beam Self Weight: BSW= 6 plf 4.5 ft from left support Total Maximum Load: wT= 226 plf Created by combining all dead and live loads. Controlling Shear: 1015 lb At support. Created by combining all dead and live loads. Comparisons with required sections: Read Provided Section Modulus: 23.48 in3 30.66 in3 Area(Shear): 8.46 in2 25.38 in2 Moment of Inertia(deflection): 49.2 in4 111.15 in4 Moment: 2283 ft-lb 2982 ft-lb Shear: 1015 lb 3045 lb NOTES Project:Chehalem B_Biggi_Lot 4 Oak Woods Beams page IJudith Souers / Location: Beam Nr. 14-Garage Floor Beam F >� Suntel Design Multi-Span Floor Beam - 16865 Boones Ferry Rd Suite 201 or [2015 International Building Code(2012 NDS)] °^'''°:Lake Oswego,OR 97035 5.125 IN x 16.5 IN x 11.0 FT _. 24F-V4-Visually Graded Western Species-Dry Use StruCalc Version 9.0.2.5 12/27/2016 4:43:10 PM Section Adequate By:37.0% Controlling Factor: Deflection DEFLECTIONS Center LOADING DIAGRAM Live Load 0.13 IN L/995 Dead Load 0.03 in Total Load 0.16 IN L/822 Live Load Deflection Criteria:L/600 Total Load Deflection Criteria: L/600 REACTIONS A B Live Load 7050 lb 7050 lb Dead Load 1613 lb 1613 lb Total Load 8663 lb 8663 lb 1 Bearing Length 2.60 in 2.60 in BEAM DATA Center Span Length 11 ft Unbraced Length-Top 1 ft 11 ft Unbraced Length-Bottom 11 ft Floor Duration Factor 1.00 Camber Adj. Factor 1 FLOOR LOADING Center Camber Required 0.03 Floor Live Load FLL= 100 psf Notch Depth 0.00 Floor Dead Load FDL= 25 psf MATERIAL PROPERTIES Floor Tributary Width Side One TW1 = 5.5 ft 24F-V4-Visually Graded Western Species Floor Tributary Width Side Two TW2= 5.5 ft Base Values Adjusted Wall Load WALL= 0 plf Bending Stress: Fb= 2400 psi Controlled by: pO1NT LOADS-CENTER SPAN Fb_cmpr= 1850 psi Fb'= 2396 psi Load Number One Cd=1.00 CI=1.00 Live Load 2000 lb Shear Stress: Fv= 265 psi Fv'= 265 psi Cd=1.00 Dead Load 0 lb Modulus of Elasticity: E= 1800 ksi E'= 1800 ksi Location 5.5 ft Min.Mod.of Elasticity: E_min= 930 ksi E_min'= 930 ksi BEAM LOADING Center Comp.1 to Grain: Fc-1= 650 psi Fc-1'= 650 psi Reduced Floor Live Load 100 psf Total Live Load 1100 plf Controlling Moment: 26574 ft-lb Total Dead Load 275 plf 5.5 Ft from left support of span 2(Center Span) Beam Self Weight 18 plf Created by combining all dead loads and live loads on span(s)2 Total Load 1393 plf Controlling Shear: -8663 lb At right support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Comparisons with required sections: Rea'd Provided Section Modulus: 133.1 in3 232.55 in3 Area(Shear): 49.04 in2 84.56 in2 Moment of Inertia(deflection): 1400.87 in4 1918.51 in4 Moment: 26574 ft-lb 46429 ft-lb Shear: -8663 lb 14939 lb NOTES $ Project:Chehalem B_Biggi_Lot 4 Oak Woods Beams Page - Judith Souers Location:CeilingJst at Garage / Floor Joist 9 „( Suntel Design 16865 Boones Ferry Rd Suite 201 of ' [2015 International Building Code(2012 NDS)] aw • Lake Oswego,OR 97035 1.5 INx11.25INx12.33FT(9.3+3)@16O.C. #2-Douglas-Fir-Larch(North)-Dry Use StruCalc Version 9.0.2.5 12/27/2016 4:43:10 PM Section Adequate By: 10.1% Controlling Factor:Moment DEFLECTIONS Center Right LOADING DIAGRAM Live Load 0.02 IN L/4823 0.04 IN 2L/2050 Dead Load -0.01 in 0.03 in Total Load -0.03 IN L/4168 0.07 IN 2L/1062 Live Load Deflection Criteria:L/480 Total Load Deflection Criteria: L/360 REACTIONS A_ Live Load 249 lb 620 lb Dead Load 11 lb 462 lb Total Load 260 lb 1082 lb Uplift(1.5 F.S) -64 lb 0 lb Bearing Length 0.28 in 1.15 in SUPPORT LOADS A Live Load 187 plf 465 plf 9.33 ft 3 ft Dead Load 8 plf 347 plf Total Load 195 plf 812 plf MATERIAL PROPERTIES JOIST DATA Center Right #2-Douglas-Fir-Larch(North) Span Length 9.33 ft 3 ft Base Values Adjusted Unbraced Length-Top 0 ft 0 ft Bending Stress: Fb= 850 psi Fb'= 597 psi Unbraced Length-Bottom 0 ft 0 ft Cd=1.00 CI=0.61 CF=1.00 Cr-1.15 Floor sheathing applied to top of joists-top of joists fully braced. Shear Stress: Fv= 180 psi Fv'= 180 psi Floor Duration Factor 1.00 Cd=1.00 JOIST LOADING Modulus of Elasticity: E= 11600 ksi E'=1 1600 ksi Uniform Floor Loading Center Right Comp. to Grain: Fc- = 625 psi Fc- = 625 psi Live Load LL= 40 psf 40 psf Controlling Moment: -1430 ft-lb Dead Load DL= 15 psf 15 psf Over right support of span 2(Center Span) Total Load TL= 55 psf 55 psf Created by combining all dead loads and live loads on span(s)2,3 TL Adj. For Joist Spacing wT= 73.3 plf 73.3 plf Controlling Shear: 587 lb Wall Loading At left support of span 3(Right Span) Wall One Live Load(-L to Joists): L1 = 0 plf 105 plf Created by combining all dead loads and live loads on span(s)2,3 Dead Load(1 to Joists)D1 = 0 plf 170 plf Comparisons with required sections: Req'd Provided Load Location X1 = 0 ft 3 ft Section Modulus: 28.75 in3 31.64 in3 Area(Shear): 4.89 in2 16.88 in2 Moment of Inertia(deflection): 82.91 in4 244.76 in4 Moment: -1430 ft-lb 1574 ft-lb Shear: 587 lb 2025 lb Decking Information Plywood Thickness: T= 3/4 in Plywood Is Glued: Moment of Inertia Calculations For Glued Floor: Joist Area: A-joist= 16.88 IN2 Plywood Area: A-ply= 2.08 IN2 Section Centroid: C= 6 IN ABOVE BASE Moment of Inertia(deflection): I-comb= 245 IN4 NOTES • • page Project:Chehalem B_Biggi_Lot 4 Oak Woods Beams •, —r— Judith Souers Location:Ceiling Jst at Garage2 f Suntel Design Floor Joist 16865 Boones Ferry Rd Suite 201 of [2015 International Building Code(2012 NDS)] fi, Lake Oswego,OR 97035 1.5 INx11.25INx10.33FT(9.3+1 )@ 12 O.C. #2-Douglas-Fir-Larch(North)-Dry Use StruCalc Version 9.0.2.5 12/27/2016 4:43:10 PM Section Adequate By:23.2% Controlling Factor:Moment DEFLECTIONS Center Right LOADING DIAGRAM Live Load -0.02 IN U6000 0.01 IN 2L/2088 Dead Load -0.01 in 0.01 in Total Load -0.03 IN L/4168 0.02 IN 201312 Live Load Deflection Criteria: U480 Total Load Deflection Criteria:L/360 REACTIONS A Live Load 187 lb 993 lb Dead Load 9 lb 706 lb Total Load 196 lb 1699 lb Uplift(1.5 F.S) -70 lb 0 lb Bearing Length 0.21 in 1.81 in SUPPORT LOADS A_ Live Load 187 plf 993 plf 9.33 ft 999909 f Dead Load 9 plf 706 plf Total Load 196 plf 1699 plf MATERIAL PROPERTIES JOIST DATA Center Right #2-Douglas-Fir-Larch(North) Span Length 9.33 ft 1 ft Base Values Adiusted Unbraced Length-Top 0 ft 0 ft Bending Stress: Fb= 850 psi Fb'= 597 psi Unbraced Length-Bottom 0 ft 0 ft Cd=1.00 C1=0.61 CF=1.00 Cf=1.15 Floor sheathing applied to top of joists-top of joists fully braced. Shear Stress: Fv= 180 psi Fv'= 180 psi Floor Duration Factor 1.00 Cd=1.00 JOIST LOADING Modulus of Elasticity: E= 11600 ksi E'=1 1600 ksi Uniform Floor Loading Center Right Comp. to Grain: Fc- = 625 psi Fc- = 625 psi Live Load LL= 40 psf 40 psf Controlling Moment: -1278 ft-lb Dead Load DL= 15 psf 15 psf Total Load TL= 55 psf 55 psf Over right support of span 2(Center Span) TL Adj.For Joist Spacing wT= 55 plf 55 plf Created by combining all dead loads and live loads on span(s)3 Wall Loading Controlling Shear: 1305 lb Wall One At left support of span 3(Right Span) Live Load(-L to Joists): L1 = 0 plf 690 plf Created by combining all dead loads and live loads on span(s)2, 3 Dead Load(L to Joists)D1 = 0 plf 560 plf Comparisons with required sections: Req'd Provided Load Location X1 = 0 ft 1 ft Section Modulus: 25.68 in3 31.64 in3 Area(Shear): 10.88 in2 16.88 in2 Moment of Inertia(deflection): 63 in4 229.48 in4 Moment: -1278 ft-lb 1574 ft-lb Shear: 1305 lb 2025 lb Decking Information Plywood Thickness: T= 3/4 in Plywood Is Glued: Moment of Inertia Calculations For Glued Floor: Joist Area: A-joist= 16.88 IN2 Plywood Area: A-ply= 1.56 IN2 Section Centroid: C= 6 IN ABOVE BASE Moment of Inertia(deflection): I-comb= 229 IN4 NOTES