Loading...
Report (30) i--�S \Ss- (31, \--\ ('1 it si'', ''!' 0 '5 \ 4' '4:4[ A' ' .44410, * / 1 k:i, ' ' it '''''''' vet. \Y> T £ / fi fOISSIL- TIGARD HIGH SCHOOL MODERNIZATION SEISMIC RESTRAINT FOR FIRE PROTECTION PIPING AND EQUIPMENT SPECIFICATION SECTION 49 Submittal#21 05 49 10/31/2018 Submitted by: Mcinstry Far Th" fe Of Your Building ®TOLCO Fig. 4A - Pipe Clampfor SwayBracingComponent of State of California OSHPD Approved Seismic Restraints System Size Range — 4"thru 8" pipe. For sizes smaller than 4" use TOLCO® Fig.4. LISTED Material — Carbon Steel Function — For bracing pipe against sway and seismic disturbance. ' Approvals — Underwriters' Laboratories Listed in the USA(UL)and Canada(cUL) --' `` ,. 4"thru 8". Included in our Seismic Restraints Catalog approved by the State of .. California Office of Statewide Health Planning and Development(OSHPD). / Installation Instructions — The Fig. 4A is the"braced pipe"attachment r,. a component of a longitudinal, lateral or riser brace assembly. It is intended to I be combined with the"bracing pipe"and TOLCO transitional and structural ! , / 1,7 d attachment component(s)to form a complete bracing assembly. NFPA 13 and/or t OSHPD guidelines should be followed. °y - r To Install — Place the Fig.4A over the pipe to be braced.Attach TOLCO '",.„, D,, /I transitional fitting, either Fig. 980, 910 or 909,to the clamp ears.Tighten bolts and -'- ,-, j nuts;torque requirement is a minimum of 50 ft. lbs.Transitional fitting attachment can pivot for adjustment to proper brace angle. --'mak -, '' Finish — Plain a € j ✓ '' Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. C - I '"-- Order By — Figure number, pipe size and finish J.-- / / 3 / / 1 / , 6 t ', e.?. Fig.4A- Longitudinal Brace o_ Fig.4A- Lateral Brace Cooper B-Line,Inc.'s("Cooper B-Line")seismic bracing components are designed to be compatible only with other Cooper B-Line bracing components, resulting in a listed seismic bracing assembly.Cooper B-Line's warranty for seismic bracing components will be the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line,except that,in addition to the other exclusions from Cooper B-Line's warranty, Cooper B-Line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. Dimensions•Weights Pipe Max.Horizontal Approx. Sizes A B C D Bolt Size Design Load Wt./100 4 8'/2 9/16 33/8 311A6 Yz 1600 221 5 9 3/4 9/16 3 7/a 4 3/e 1/z 1600 253 6 11 1/2 5/8 5 5'/8 1/2 2015 513 8 13'/4 3/4 61K6 6'/ 1/2 2015 601 COOPER B-LINE 1375 Sampson Ave•Corona,CA 92879•800.786.5266•FAX:951.737.0330 www.tolco.com COOPER B-Line Seismic Bracing Fig. 800-Adjustable Sway Brace Attachment to SteelLCO _ - Size Range: 4"(101.6mm)thru 18"(457.2mm)beam width C ell US Material: Steel LISTED Function: Seismic brace attachment to steel. Features: This product's design incorporates a concentric attachment point which is critical to the performance of structural seismic connections. NFPA 13 indicates the importance of concentric loading of connections and fasteners. Permits secure go :: connection to steel where drilling and/or welding of brace connection could present I1116.1% to structural issues. t Installation Instructions: Fig. 800 is the structural attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with a .4 TOLCO transitional attachment, "bracing pipe"and a TOLCO "braced pipe" 417.0 � attachment to form a complete bracing assembly. NFPA 13 guidelines should be followed. Set Bolts&Hardware To Install: Place the Fig. 800 on the steel beam,tighten the cone point set bolts Included �/ on flange until the heads break off.Tighten hex head bolts into clamp body until lock mo washers are fully flat.Attach other TOLCO transitional attachment fitting, Fig. 980, 910, 909, or any other TOLCO approved transitional fitting. Transitional fitting attachment can pivot for adjustment to proper brace angle. Approvals: Underwriters Laboratories Listed in the USA(UL)and Canada(cUL). ;r For FM Approval information refer to page 55. - Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Figure number,type number and size number. II J moo •Fits Beam I Max.Design Loads(cULus) Part No. Flange Along Beam Across Beam �v / I•'' in. (mm) lbs. (kN) lbs. (kN) ��////�///// N intigitimmi 800-1 4"-6" (101.6-152.4) lel 41 rer 800-2 6"-8" (152.4-203.2) / `4 Shown with Fig.980 / 800-3 8"-10" (203.2-254.01 . // ,/•# brace fitting to 800-4 10"-12" (254.0-304.8) 1265 (5.62) 2015 (8.96) \ , • pipe brace 800-5 12"-14" 1304.8-355.6) / (Across Beam) 800-6 14"-16" (355.6-406.4) 800-7 16"-18" (406.4-457.2) IP M� ■I AFits Beam Flange Max.Design Loads(cULus) Type Thickness Along Beam Across Beam in. (mm) lbs. (kN) lbs. (kN) r//// /////': 1 Up to 3/4" (Up to 19.0) 1265 (5.62) 2015 (8.96) rir11 sui '•' rrir 2 3/4"to 11/4"(19.0 to 31.7) 1265 (5.62) 2015 (8.96) 1 Shown with Fig.980 braceIII fitting to pipe brace (Along Beam) Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting in a listed seismic bracing assembly. B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from B-Line's warranty, Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line by 54 Fire Protection Solutions Seismic Bracing OTOLCCr Fig. 825 - Bar Joist Sway Brace Attachment To Steel " Size Range: One size accommodates all c filli us Fig. 900 Series sway brace attachments. Maximum Horizontal Design Load 2015 lbs (8.96kN). LISTED • Material: Steel j LA Function: To attach sway bracing and hanger assemblies ' to steel members. t a t� Features: This product's design incorporates a concentric I a „ attachment point which is critical to the performance of ie�� it% �� (9.5) structural seismic connections. NFPA 13 indicates the importance of concentric loading of connections and m - 4 INflit�t,!m fasteners. Permits secure non-friction connection without ®4 ��e!!!� drilling or welding. Unique design reinforces point of connection to joist. Break off head 0, ��� set bolt design assures verification of proper installation torque (min. 31 ft.-lbs.). 44 �4. '�.� Approvals: Underwriters Laboratories Listed in the USA(UL)and Canada(cUL). 't� For FM Approval information refer to page 57. Set Bolts&Hardware Installation Instructions: Fig. 825 is the structural attachment component Included of a longitudinal or lateral sway brace assembly. It is intended to be combined with a TOLCO transitional attachment, "bracing pipe"and a TOLCO "braced pipe" attachment,to form a complete bracing assembly. NFPA 13 guidelines should be followed. Maximum Design Load 2015 lbs.(8.96kN) To Install: Place the Fig. 825 on the steel beam,tighten the cone point set bolts until heads break off.Attach other TOLCO transitional attachment fitting, Fig. 980, UL Listed as Hanger Attachment for 910, 909, or any other TOLCO approved transitional fitting.Transitional fitting 6"(150mm)Pipe at Maximum Spacing attachment can pivot for adjustment to proper brace angle. Finish: Plain, Electro-Galvanized and HDG Approx.Wt./100: 247.5 Lbs. (112.2kg) Order By: Figure number and finish Shown with Y g r Fig.910 US Patent#6,098,942, Canada Patent#2,286,659 4 Fig. Fig. 1000 % '\ 825 -_-- - ---, JL T - gip---n-�,- i i 1" I J _ May pivot in any ; (254mm) ... °O BMI direction 1/2" Bolt&Nut `� Furnished Side View Top View Fig.825 Shown with - - �� . ,p �_W.. - . Max. Fig.980 1M 6"(152.4mm) em Bar joist shown attached J it Fig.825 to various roof material I-Beam Fig. 1000 �iV/hown with Brace -J Fig.910 AiAliii' imint O� May pecti n any direction •, *.• Front View Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting in a listed seismic bracing assembly. B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from B-Line's warranty, Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. ■ All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Fire Protection Solutions by � . 56 Seismic Bracing Ismiza- Fig. 825A- Bar Joist Sway Brace Attachment To Steel Size Range: One size accommodates all Fig. 900.Series sway brace C OS attachments. Maximum Horizontal Design Load 1600 lbs(7.11kN). LISTED' Material: Steel Set Bolts&Hardware Function: To attach sway bracing to steel open web structural members. Included Features: This product's design incorporates a concentric attachment Illt� 3/$" point which is critical to the performance of structural seismic connections. iitihni (9.5) NFPA 13 indicates the importance of concentric loading of connections and fasteners. Permits secure non-friction connection without I 111141114111 drilling or welding. Unique design reinforces point of connection to joist. Break off head bolt design assures verification of proper installation. ¼ii Approvals: Underwriters Laboratories Listed in the USA(UL)and Canada (cUL). Installation Instructions: Fig. 825A is the structural attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with a TOLCO transitional attachment, "bracing pipe"and a TOLCO"braced pipe" Maximum Design Load attachment to form a complete bracing assembly. NFPA 13 guidelines should be 1600 lbs. followed. To Install: Place the Fig. 825A on the steel beam, tighten the cone point set bolts until heads break off.Attach other TOLCO transitional attachment fitting, Fig. 980, 910, 909, or any other TOLCO approved transitional fitting.Transitional fitting attachment can pivot for adjustment to proper brace angle. Finish: Plain or Electro-Galvanized - � Approx.Wt./100: 154.5 Lbs. (70.1 kg) Order By: Figure number and finish Patent#6,098,942 Bar joist shown attached to Max. various roof materials 6"1152.4mm) Ellia /May pivot in any own with direction Fig.980 iii.... iiiiIIIM ci> Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting in a listed seismic bracing assembly. B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line,except that, in addition to the other exclusions from B-Line's warranty, Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line by 60 Fire Protection Solutions Y Seismic Bracing TOLCO'' Fig. 1001 - Sway Brace Attachment Component of State of California OSHPD Approved Seismic Restraints System Size Range: Pipe size to be braced: 1"(25mm)thru 8"(200mm)IPS. * Pipe size used for bracing: 1"(25mm) and 11/4"(32mm)Schedule 40 IPS. Material: Steel h us ifit 0 LISTED APPROVED Function: For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system: Fig. 1001 is used in conjunction with a Fig. 900 Series fitting and joined together with bracing pipe per NFPA 13, forming a complete sway brace assembly. Features: Can be used to brace schedules 7 through 40 IPS. Field adjustable, % making critical pre-engineering of bracing pipe length unnecessary. Unique designr.' requires no threading of bracing pipe. Can be used as a component of a four-way CJ0gfid ":.' riser brace. Comes assembled and ready for installation. Fig. 1001 has built-in . visual verification of correct installation. See installation note below. \ Set Screwstiga j Installation Note: Position Fig. 1001 over the pipe to be braced and tighten �J Included Baa a*L4 two hex head cone point set screws until heads bottom out.A minimum of 4 1"(25mm) pipe extension is recommended. Brace pipe can be installed on top or Pipe Max.Horizontal Design Load(UL)-Lbs. bottom of pipe to be braced. 1 Size For Brace Pipe Size 1"/11/4" Approvals: Underwriters Laboratories Listed in the USA and Canada (cULus). Sch.7 Sch.10 Sch.40 Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints in. (mm) 1••/11/4" 1"/11/4" 1••/11/4" Catalog approved by the State of California Office of Statewide Health Planning 1" ',(25) / 1000/1000 1000/1000 and Development(OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic 11/4" (32) 1000/1000 1000/1000 1000/1000 Restraint Systems Guidelines, OPA-0300-10. 11/2" ',(40) 1000/1000 1500/1500 1500/1500 Finish: Plain or Electro-Galvanized. Contact customer service for alternative 2" (50) 1000/1000 2015/2015 2015/2015 finishes and materials. 21/2" (65) 1600/1600 2015/2765 2015/2765 Order By: Indicate pipe size to be braced followed by pipe size used for bracing, 3" (80) 1600/1600 2015!2765 2015/2765 figure number and finish. Important Note: Fig. 1001 is precision manufactured to perform its function as 4" (100) 1600/1600 2015/2765 2015/2765 a critical component of a complete bracing assembly.To ensure performance,the 6" (150) 1600/1600 2015/2765 2015/2765 UL Listing requires that Fig. 1001 must be used only with other TOLCO bracing 8" (200) .1600/1600 2015/2765 2015/2765 products. Part Number&Approx.Wt./100 1 Max.Horizontal Design Load(FM) Pipe For Sch.7,Sch.10,&Sch.40 Pipe 1.2,3 Size 1"(24mm)Brace Pipe 11/4"(32mm)Brace Pipe 30°-44° 45°-59° 60°-74° 75°-90° in. (mm) Lbs. (kg) Lbs. (kg) Lbs. (kN) Lbs. (kN) Lbs. (kN) Lbs. (kN) 1" (25) 1001-1 X 1 100.0 (45.3) °= 1001-1 X 11/4 118.0 (53.5) 1800 (8.00) 2550 (11,34) 3120(13.88) 3490 (25.52) 11/4" (32) 1001-11/4 X 1 100.0 (45.3) 1001-11/4 X 11/4 114.0 (51,7) ? 1230 (5.47) 1740 (7.74) 2140 (9.52) 2380 (10.58) 11/2" (40) 1001-11/z X 1 100.0; (45.3) 1001-11/2 X 11/4115.0 (52.1) ' 1230 (5.47) 1740 (7.74) 2140 (9.52) 2380 (10.58) 2" (50) 1001-2 X 1 108.0 (49.0) 1001-2 X 11/4 121.0 (54.9) < 1230 (5.47) 1740 (7.74) 2140 (9.52) 2380 (10.58) 21/Y (65)' 1001=71i2rr' 138.6 (62.8) 1001-21/2 X 11/4 160.4 (72.7) 800 (3.56) 1130 (5.02) _ 1380 (6.14) 1540 (6.85) 3" (80) 1001-3 X 1 147.2 (66.7) 1001-3 X 11/4 168.7 (76,5) 850 (3.78) 1200 (5.34) 1470 (6.54) 1640 (7.29) 4" (100) 1001-4 X 1 160.9', (73.0) ` 1001-4 X 11/4 182.4 (82.7) , 850 (3.78) 1200 (5.34) 1470 (6.54) 1640 (7.29) 6" (150) 1001-6 X 1 190.0 (86.2) 1001-6 X 11/4 211.4 (95.9) l; 510 (2.27) 730 (3.25) 890 (3.96) 990 (4.40) 8" (200) 1001-8 X 1 217.4 (98.6) i 1001-8 X 11/4 238.8 (108.3) 510 (2.27) 730 (3.25) 890 (3.96) 990 (4.40) 1 FM Approved when used with 1 or 11/4 inch NPS Schedule 40 GB/T 3091,EN 10255H,or JIS G3451 steel pipe as the brace member. 2 Load rating for LW above refers to FM Approved Lightwall Pipe commonly referred to as"Schedule 7".These ratings may also be applied when EN 10220 and GB/T 8163 steel pipe. 3 Load rating for Schedule 10 above may be applied to GB/T 3092,EN 10255M and H,or JIS G3454, FM Approved Thinwall, or Schedule 40 steel pipes. Note: See UL load ratings in UL Listed Design Load chart shown under drawing. (,e_ Si1 Ii Nt. 0 IF.1 to ■ All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 193 B-Line series Pipe Hangers&Supports