Plans (9) ID * 0351 GENERAL NOTES INDEX OF DRAWINGS PROJECT & BUILDING INFORMATION CONTACT INFORMATION CLR A1.0 NOTES,PROJECT INFORMATION,SITE PLAN 1. ALL WORK SHALL CONFORM TO APPLICABLE CURRENT FEDERAL,STATE AND LOCAL CODES, THE CONTRACTOR IS TO PROVIDE FOR ALL PROJECT ADDRESS' WASHINGTON SQUARE APPLICANT: CHIN-LEY/RECHE ASSOCIATES REQUIRED NOTIFICATION OF AND COORDINATION WITH THE CITY AND STATE AGENCIES,AND PROVIDE REQUIRED PERMITS. ALL TESTS AND Al.1 PROJECT SPECIFICATIONS 9677 WASHINGTON SQUARE RD 1516 MELROSE AVENUE Chin-Ley/Reche INSPECTIONS ASSOCIATED WITH OBTAINING APPROVALS TO PROCEED WITH AND COMPLETE THE WORK SHALL BE PAID FOR BY THE A2.0 CONSTRUCTION PLAN TIGARD,OR 97223 SUITE 200 CONTRACTOR .1FINISH PLAN SEATTLE,WA 98122 1516 Melrose Ave.,Suite 200 A3.0 REFLECTED CEILING PLAN ASSESSOR'S PARCEL NUMBER: IS126CC00100 A4.0 EXTERIOR ELEVATIONS/INTERIOR ELEVATIONS CONTACT: Seattle,W150ton 98122 2.THE CONTRACTOR SHALL COORDINATE WITH THE OWNER,INCLUDING AREA FOR WORK,MATERIALS STORAGE,ACCESS TO AND FROM THE A4.1 INTERIOR ELEVATIONS LEGAL DESCRIPTION: SERGIO CHIN-LEY 938 206 938 1501 WORK,SPECIAL CONDITIONS DR NOISY WORK,TIMING OF WORK AND INTERRUPTIONS OF MECHANICAL AND ELECTRICAL SERVICES- A5.0 DETAILS TEL:206.938.1501 FAX:206,935-3449 3. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE HIGHEST STANDARD OF WORKMANSHIP IN GENERAL AND WITH SUCH K-1 KITCHEN EQUIPMENT PLAN EMAIL:sergio@chinleyreche.com STANDARDS AS ARE SPECIFIED. K-2 KITCHEN EQUIPMENT SCHEDULE EXISTING OCCUPANCY CLASSIFICATION:M(MERCANTILE) TENANT: DING TAI FUNG 4. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE AND NOTIFY DESIGNER/ARCHITECT OF ANY DISCREPANCIES. 700 BELLEVUE WAY NE#280 CONTRACTOR IS NOT TO SCALE OFF DRAWINGS. BELLEVUE,WA 99004 _ P1 ri 1 / D 5. CONTRACTOR SHALL PROVIDE 16 GAUGE SHEET METAL BACKING IN PARTITIONS FOR ALL WALL MOUNTED FIXTURES AND DEVICES UNLESS CONTACT,DAVID WASIELEWSKI 1 111111ME 1 i��dd__IRr"s+. iY/ INDICATED OTHERWISE ON THE DRAWINGS. TEL:206.953.0770 IN �� TYPE OF CONSTRUCTION: II • Oavewas@holrnail.com I. � ,- II o i JUL2 2018 6. ALL MATERIALS INDICATED TO MATCH EXISTING SHALL DO SO WITH RESPECT TO SIZE,COLOR,TEXTURE,PATTERN,QUALITY AND METHOD OF INSTALLATION INSOFAR AS PRACTICABLE AND SHALL BE APPROVED BY THE DESIGNERIARCHITECT BEFORE USE. ARCHITECT/DESIGNER: CHIN-LEY/RECHE ASSOCIATES PROJECT AREA: 9,1315-F, �- 1 I ��- CITY OF TIGA iD 1516 MELROSE AVENUE v i i 1 7- EXISTING WORK DAMAGED AS A RESULT OF WORK UNDER THIS CONTRACT SHALL BE REPAIRED TO ORIGINAL CONDITION AND FINISHED TO SUITE 200 I IIM U BUILDING DIVISION MATCH ADJACENT FINISHES,SUBJECT TO OWNER'S APPROVAL,AT NO ADDITIONAL COST TO OWNER. ALL REPLACEMENT MATERIAL REQUIRED TOTAL STORIES: 1 SEATTLE,WA 98122 TO MATCH EXISTING MATERIALS SHALL DO SO WITH RESPECT TO TYPE,PATTERN,TEXTURE,SIZE,SHAPE,COLOR AND METHOD OF PROJECT STORY: GROUND INSTALLATION INSOFAR AS PRACTICAL,AND SHALL BE APPROVED BY THE DESIGNER/ARCHITECT AND OWNER PRIOR TO INSTALLATION. CONTACT:SERGIO CHIN-LEY FIRE SPRINKLERED: YES-FULLY SPRINKLERED TEL 20b.938.1501 -- 1 1._ / 8. ALL EXISTING MECHANICAL AND ELECTRICAL EQUIPMENT AND SERVICE DISRUPTED OR REMOVED DURING CONSTRUCTION SHALL BE FAX:206.935.3449 RESTORED AND REPLACED UNLESS NOTED OTHERWISE. EMAIL:sergio@chinleyreche.com 9 INSTALLATIONS OF MECHANICAL,ELECTRICAL AND STRUCTURAL SYSTEMS WILL REQUIRE OPENING OF SOME EXISTING WALLS,CEILINGS, PROJECT DESCRIPTION 21•all OR FLOOR CAVITIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF THESE OPENINGS TO MATCH EXISTING,EXCEPT WHERE NOTED OTHERWISE. FILL ALL HOLES AND VOIDS IN FLOORS,WALLS AND CEILINGS WHICH RESULT FROM INSTALLATION OF WORK,AND REMOVAL OF EXISTING MATERIALS AND EQUIPMENT REQUIRED BY THIS CONTRACT. PATCHED AREAS SHALL MATCH THE MATERIALS, INTERIOR TENANT IMPROVEMENT FOR A RESTAURANT-NO CHANGE OF USE,NO FINISHES,AND LEVELS ADJACENT,OR SHALL BE PUT IN THE PROPER CONDITION TO RECEIVE THE FINISH INDICATED- EXTERIOR WORK,NO SITE WORK 10_ MATERIALS,ARTICLES,DEVICES AND PRODUCTS ARE SPECIFIED IN THE DOCUMENTS BY LISTING ACCEPTABLE MANUFACTURERS OR OCCUPANCY LOAD BATHROOM PLUMBING FIXTURES PRODUCTS,BY REQUIRING COMPLIANCE WITH REFERENCED STANDARDS OR BY PERFORMANCE SPECIFICATIONS. FOR ITEMS SPECIFIED BY - - NAME,SELECT ANY PRODUCT NAMED. FOR THOSE SPECIFIED BY REFERENCE STANDARD OR BY PERFORMANCE SPECIFICATIONS SELECT ANY ASSEMBLY-MAIN FLOOR: 4670 SF/15=312 TOTAL OCCUPANT LOAD= 33612=168 PER GENDER PRODUCT MEETING OR EXCEEDING SPECIFIED CRITERIA. FOR APPROVAL OF AN ITEM NOT SPECIFIED,SUBMIT FOUR(4)COPIES OF COMPLETE will ifilirio BACK-UP INFORMATION FOR PURPOSES OF EVALUATION, WHERE BUILDING STANDARD ITEMS ARE CALLED FOR,NO SUBSTITUTE WILL BE PER TABLE 2902.1: ACCEPTED. CODE INFORMATION WOMEN'S BATHROOM- 3 TOILETS,I LAVS REQUIRED FOOD PREP/WORKROOM: 4560 SF 1200=23 II 11. CONTRACTOR SHALL PROVIDE FOR ALL WORK REQUIRED TO MAINTAIN COMPLIANCE WITH LOCAL FIRE CODE. TOTAL OCCUPANCY: 335 MEN'S BATHROOM- 3 TOILETS,1 LAYS REQUIRED I E BUILDING CODES: 2014 OREGON STRUCTURAL SPECIALTY CODE,2012 IBC. 12. MECHANICAL AND ELECTRICAL FIXTURES,OUTLETS,ETC.WHEN SHOWN ON THE ARCHITECTURAL DRAWINGS ARE FOR LOCATION OCCUPANCY GROUP: A INFORMATION ONLY. MECHANICAL AND ELECTRICAL TO BE DESIGNED BY OTHERS. ALL CIRCUITING COORDINATION 70 BE BY OTHERS. ACCESSIBILITY CODE: ANSI At 17.1 I y PROVIDED; NUMBER OF EXITS REQUIRED: 2 WOMEN'S BATHROOM- 3 TOILETS,3 LAVS LIFE SAFETY CODE: OREGON FIRE CODE 2014 �' 13. CONTRACTOR SHALL COORDINATE WITH OWNER FOR APPROVAL OF LOCATIONS OF ALL HVAC THERMOSTATS,GRILLES,AND DIFFUSERS, �y FIRE AND SMOKE DETECTION DEVICES INCLUDING SPRINKLERS,FIRE EXTINGUISHERS AND HOSE CABINETS ETC. MEN'S BATHROOM- 2 TOILETS,3 URINALS,2 LAVS r I °//Q/��� ENERGY CODE: 2014 OREGON ENERGY EFFICIENCY SPECIALTY CODE,2009 REFER TO EGRESS PLAN DIAGRAM BELOW FOR AREA OCCUPANCY ��!/��� INTERNATIONAL ENERGY CONSERVATIO CODE ��1'' v 14. ANY CHANGE IN LIGHT FIXTURE PLACEMENT DUETO INTERFERENCE OF MECHANICAL OR STRUCTURAL COMPONENTS SHALL BE SUMMARY - € APPROVED BY OWNER. ' ° r' MINIMUM DISTANCE BETWEEN EXITS REQ.: 48' - 15. ALL FLOORS SHALL BE LEVEL. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING ANY CONDITIONS THAT DO NOT MEET THIS I I STANDARD. DISTANCE BETWEEN EXITS. 115' 16. FLOOR FINISH TRANSITIONS SHALL OCCUR UNDER DOORS,UNLESS SHOWN OR NOTED OTHERWISE. MAXIMUM TRAVEL DISTANCE: 145' �- PROJECJ SITE 0 WASHINGTON SQUARE MALL 17.MECHANICAL,PLUMBING&ELECTRICAL SHALL BE DESIGN BUILD UNLESS OTHERWISE REQUIRED BY LOCAL JURISDICTION- !{! DEFERRED/RELATED PERMIT SUBMITTALS - 18.MECHANICAL,PLUMBING 8 ELECTRICAL DESIGN BUILD.PROVIDE SCHEMATIC DRAWINGS TO OWNER FOR REVIEW AND WRITTEN APPROVAL. PROVIDE OPERATIONAL AND MAINTENANCE MANUAL TO OWNER PRIOR TO CLOSE OUR OF JOB AND FINAL PAYMENT. ELECTRICAL,PLUMBING,MECHANICAL,AND FIRE SPRINKLER PERMIT SUBMITTALS - 19. THE DESIGNER/ARCHITECT AND/OR THE OWNER WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS,METHODS,TECHNIQUES, BY TRADES UNDER SEPARATE SUBMITTAL- - SEQUENCES OR PROCEDURES,OR FOR THE SAFETY PRECAUTIONS OR PROGRAMS IN CONNECTION WITH THE WORK. THE in - __-- DESIGNER/ARCHITECT DESIGNERIARCHITECT AND/OR THE OWNER WILL NOT BE RESPONSIBLE FOR THE ACTS OR OMISSIONS OF ANY CONTRACTORS, NO DEMOLITION WORK. SUBCONTRACTORS,OR ANY OF THEIR AGENTS OR EMPLOYEES,OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK. FREEZERS AND COOLERS SHALL REQUIRE SEPARATE MECHANICAL PERMITS. 20,CONTRACTOR SHALL PROVIDE AIR BALANCING BY AN INDEPENDENT AIR BALANCING FIRM. 21.CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR ALL CASEWORK,SPECIALTY WALL TREATMENTS,FLOOR PATTERNS,STONE INSTALLATIONS AND COUNTERTOPS FOR REVIEW AND APPROVAL BY DESIGNER/ARCHITECT. 22.CONTRACTOR SHALL ACQUIRE PUBLIC WORKS APPROVAL PRIOR TO PERFORMING ANY WORK WITHIN THE CITY RIGHT-OF-WAY(SIDEWALK e VICINITY MAP OR ROAD). N NOT TO SCALE LANDLORD NOTES I. General Contractor to coordinate all Dumpster/Trash Removal activities with Mall Operations. 2. These plans should be forwarded to the awarded General Contractor to be on-site at all times. 3. Tenant's Contractor must repair any/all Landlord property damaged during T.I.work and complete Landlord's punchlist as directed by Landlord's representative. 4. Tenants Contractor must contract with Mall's required vendors-see criteria for info. 5. Prior to saw cutting or penetrating the existing slab,verify location with on-site Landlord representative_Tenant's contractor will be responsible for any damage to existing mall utility conduits. �1 ( S,, ..4 la 11°11S( 6. Tenant General Contractor must protect mall tile floor between barricade and storefront.Any damage occurred during construction must be replaced at Tenants expense. ' . 7. Nothing is permitted to be attached to,suspended from,or penetrate the roof deck above.You are required to frame, OFGA� brace and/or suspend,as needed,to/from the top chord of joists or structural steel which exist above your respective Approved.1.1...N.N.1....M..1M...... tenant space. I Conditionally Approved ........ 8. A water shut off valve must be installed at eye level,using a ball-type valve,and clearly labeled"water shut-off valve". �� ..r.,��„.■ ■ _ Provide a floor drain in toilet room. ,,i Letter to:Follow...,..............E j 9. Signage must be submitted under a separate cover for Landlord review and approval. I 111 I Attached .........1..... I�� _ a _ ELI I = r■■ _ �' _ _._. Permit Number: : - i''" . • l H ce ca u�el t '� �1Z� Addt AN Rel.rl la / I r -- as LL III � os�. MECHANICAL AND ENERGY NOTES , ° =_-1 itil G ° Q �r O ��I I BT� ` Date: -fir AEI sF- c t li.f 1.NOT USED � �' La I I F- I ® 1l� r' - " 3€ © I17d!2.NOT USED =_ ` ,ii I i �3-NOT USED Mi i 1 r1�T11 Ili 'I._�; �r I rL 4.INDOOR DESIGN TEMPERATURES SHALL BE 70 DEGREES F.FOR HEATING AND 78 DEGREES F. FOR COOLING. ALL GLASS TO BE INSULATING - ',MI Ill '� • I 0 II S TYPE.THICKNESS AS DESIGNED BY MANUFACTURERS. _ ��� „1 I 1 I!'LI Q cm 5.5.ALL OPENINGS TO BE CAULKED,WEATHERSTRIPPED,OR SEALED. TEARS AND JOINTS IN BATT INSULATION TO BE SEALED WITH TAPE. :t' i_ ,,1,� I O l C.' p it l 6.HEATING AND VENTILATION SYSTEM TO BE COMPRISED OF A SUPPLY AND RETURN AIR SYSTEM- SYSTEM TO BE FORCED AIR. -'=- _. .. ..._ i - ip L7 lip ' U ME r, IIIIIii I now . 7 li t_ifii, Lips Iltrit * 1 =LI --:II�' -. LEGEND ;i,�• �':-_���_:�� � \ 1 ELEVATION j I I PATH OF EGRESS ---? project title: O _ Ding 2 i, � F Washington Square Was Talon S Fung 4ell INTERIOR I ir * IMO' II gt SHEET ELEVATION �Irt F`Ili , _�' ,I .I 1.r Irit,l aro 3 NUMBER 1111 IiO�i I II ■[ 1 �I I 11 I I I 9677 SW Washington Square Road 1, + IlIIL: ,Ili - ICIM IMIl_ I tl 9 1 Tigard,OR 97223 Ars DETAIL - - =_:�E 1r�w , t! :«9111 I _ r - - - i•-"1 DETAILS 0I-- III,- r IIS } NVSHEET l r _i1I ,I_ m l' ■I III lilt l I I I NUMBER illi. �LJL� I �r.,I �[ t. o I) Ca CEILING tat r1 III TYPE Il'� �1111i I'' '�+ ■I ��um .O ■ IiC Ir I w aka SECTION I�� I I IE i ii \� 4I i� r I I I co) BUILDING 11,Ilii I! �■? `, ll. gir I t "ISECTIIOS9 - HEIGHT � N M 1I I11 ■ �1 I ' LI L� �j417 SHEET HEIGHT ■ra C;�� O !ri. II ENUMBERI .I. � l �� � I V 1 NI i. Ir 14-6=. I '.05:I II II II i tr C, ABBREVIATIONS 1V-1 - ANI EEE .. .. . _. r IRd _€ -RM---_ :I± \ dote: description: ACT=ACOUSTICAL CEILING TILE HW=HOT WATER � � L-€�-€ _ (L_ AFP=ACOUSTICAL FABRIC PANEL LRV=LIGHT REFLECTANCE VALUE 1�,..�� !`€'1:,= 03.12.18 preliminary design AFF=ABOVE FINISHED FLOOR NIC=NOT IN CONTRACT 1iER COAT I o lt V u I ,�_ A t" EX=EXPLOSION PROOF RCP PREFDLECTED CEILING PLAN i=T"iw� li 1'� e it,'�i4 r n \ I:. I1 I 04.0'1 18 coordination CFCI=FURNISHED&INSTALLED BY CONTRACTOR TBD=TO BE DETERMINED pill . FIS iF I 11 I 1 OFOI=FURNISHED&INSTALLED BY OWNER TYP=TYPICAL `` 1lCll6°a�L4II�1ig,,ji;11911 �,P�Y�IL 1 II � ,� \ �o r-y ii I g I 04 23'l.8_ review OFCI=FURNISHED BY OWNER INSTALLED BY CONTRACTOR UNO=UNLESS NOTED OTHERWISE 1 1 i ' FIN=DIMENSION TO FINISHED FACE OF WALL WP=WEATHER PROOF ill - L- _.-- _ III. IN. U. ,:0 ___.- NO- I I 04 30 18 PERMIT review FRP=FIBERGLASS REINFORCED PANEL +46-=INDICATES HEIGHT ABOVE FINISHED FLOOR -- �� Y��,I�1 FS=FLOOR SINK OR ABOVE FINISHED GRADE TO TOP OF DEVICE- - ^t li i ? T �� u ❑ \ II'j` I 1 GWB=GYPSUM WALL BOARD =- �-1 r�-7y i�; I ( I 05.01 18 PRICING SET I \113 -1! IIIA' ll HM=HOLLOW METAL i1- . Ii..• -- ,;3 1 _� nu, n _ illi- -�-y �; l�� IIILI' I :11 f I " [ I i 1 s - IiI yI T Ti I \ Ii i _ j _ ❑ I �� e. I LLI III1=_ ==3 ,____ __. Es �•� I� i I i� I i ii I =. I II 1 I L- -. Cn IMtfAgr!" yl• f • (0Q1 Z • PATH OF EGRESS �\ laP Illi Iisir�� :�Y_YI .. .`\ i \. r , i[IN - el El ; I `s ,..t\ 04 t. I 1 641 ,. 6iil «.« ..,.« . «.� «�..«. Is` u . 0 [ OMI1 •_ .. w . ..... spal mime - date: --/ May 1,2018 drowing title PROJECT DOCUMENTS N EGRESS PLAN n,;r-n�, ,_ SCALE:118--1'-0' A1 •0 PL M N S M OL L ST LANDLORD ENERAL PL M N NOTES CLR NOTE:This is a standard s m of list and not all items listed ma eased. AT E R SER CE CALC LAT ONS A. TENANT SHALL PROVIDE A MAIN SHUT-OFF VALVE LOCATED AT EYE LEVEL IN A WALL BEHIND A LABELED Chin-Ley/Reche A re iation / / PIPE OR CONDUIT BELOW GRADE r2:1 NATURAL GAS PIPING CONNECTION ASSEMBLY ACCESS DOOR.LOCATE IN OR NEAR EMPLOYEE RESTROOM AS DESIGNATED BY LANDLORD. 1516 Melrose Ave.,Suite 200 ASED ON APPEND X A B. TOILET FACILITIES SHALL BE DESIGNED IN COMPLIANCE WITH ALL APPLICABLE ADA BUILDING Seattle,Washigton 98122 NUMBER j CONTINUATION DZ PRESSURE REDUCING VALVE DEPARTMENT CODES. 206 9381501 Atop Rik F XT RE ANT T APPEND X A-TA LE A-2 TOTAL F XT RE N TS C. PROVIDE A 3"FLOOR DRAIN AND CLEAN-OUT. DETAIL NUMBER AND SHEET LOCATION C a SHUTOFF VALVE,GENERAL P L C P L CON 411 (E) EXISTING VP ENERALENERAL COLD OT D. EACH RESTROOM MUST HAVE AN EXHAUST SYSTEM. IJ (N) NEW CIP EQUIPMENT IDENTIFICATION SE DESCR PT ON SE ATER ATER E. FLOOR FINISHES IN TOILET ROOMS SHALL BE CERAMIC TILE WITH A COVERED 6'BASE. U. W LOCATION 3 DISHWASHER 1.50 4.50 3.38 F. TENANT IS REQUIRED TO PROVIDE A WATERPROOF MEMBRANE BENEATH THE FINISH FLOOR SURFACE UP U$2- (X) (X) DEMOLISH co EXTENT OF DEMOLITION 2 3-COMP.SINKS 4.00 8.00 6.00 TOA HEIGHT OF 4'ALONG ALL WALLS. F.,(5, 11 SINKS 3.00 33.00 24.75 +Z+E AT 5 HAND SINK 2.00 10.00 7.50 G. TOILET ROOM WALLS AND CEILINGS SHALL BE CONSTRUCTED OF METAL STUDS WITH WATER RESISTANT X FIXTURE TAG(LEVEL BELOW FIXTURE) 3 WOK FAUCETS _ 2.00 6.00 4.50 5/8"TYPE'X'GYPSUM BOARD APPLIED TO THE INTERIOR SIDE OF THE TOILET ROOM.AT A MINIMUM, ' FOOT,FEET 7 LAVATORY 1.00 7.00 5.25 INTERIOR WALL FINISHES SHALL BE A LIGHT COLORED ENAMEL PAINT WITH A4'-0"HIGH WAINSCOT 3 1 SERVICE SINK OR MOP BASIN 3.00 3.00 2.25 EXTENDING 24'ON EACH SIDE OF,AND 24"BEYOND THE FRONT PORTION OF ANY WATER CLOSET OR *x FOOD SERVICE EQUIPMENT/CALCULATION TAG to A AQUASTAT,ARCHITECT,ANCHOR,AMPHERE 3 URINAL,0.125 GPF 4.00 12.00 - URINAL. i$ i g I M. 7 WATER CLOSET,1.28 GPF,GRAVITY TANK 2.50 17.50 - H. THE CEILING SHALL BE A MINIMUM OF 8'-(Y ABOVE THE FINISHED FLOOR LEVEL,BE CONSTRUCTED OF 6/8E ° m P. M i f ADA AMERICANS WITH DISABILITIES ACT () KEYED NOTE TOTAL 101.00 5383 TYPE"X"WATER RESISTANT GYPSUM AND BE FINISHED WITH ENAMEL PAINT.THE CEILING SHALL CONTAIN g a ti JA VENT,WHICH SHALL BE CONNECTED TO THE LANDLORDS EXHAUST SYSTEM OR A PURSUANT TO THE CITY t t 8 AP ACCESS PANEL FLOW IN GPM 68 30 REQUIREMENTS. / / PIPE BELOW GRADE IRRIGATION FLOW IN GPM 0 a. v$ AVB ATMOSPHERIC VACUUM BREAKER TOTAL GPM REQUIRED 68 BFF BELOW FINISHED FLOOR (a POINT OF CONNECTION a. MINIMUM DAILY SERVICE PRESSURE(BOOSTER PUMP) 74 si STATIC HEAD LOSS .434/FT X 5 FT HGT. 2.17 SI o. WATER METER PRESSURE DROP METER SIZE 5 Si BFP BACKFLOW PREVENTER d. BACKFLOW PREVENTER RPBP DCVA MODEL TYPE 5 Si BLDG BUILDING Pi ing Fitting e. PRESSURE REQUIRED AT FIXTURE 30 Si PRESSURE AVAILABLE FOR BTU BRITISH THERMAL UNIT I-I -AP ACCESS PANEL FRICTION LOSS,e- -c-d-e 31.83 Si BTUH BRITISH THERMAL UNITS PER HOUR ,TOTAL EQUIVALENT PIPE LENGTH 4 AQUASTAT 218 LENGTH X 1.25 , 272.5 ft BV BALANCING VALVE MAXIMUM FRICTION LOSS CFH CUBIC FEET PER HOUR 3 CAP PRESS,AVAIL.X 1007EQUIV.LENGTH 11.681 si CO CLEANOUT ,SERVICE SIZE FROM METER TO BUILDING 21/2 COTG CLEANOUT TO GRADE CONT. CONTINUATION D" CONCENTRIC REDUCER CP CIRCULATION PUMP CV CHECK VALVE °- ECCENTRIC REDUCER SAN TAR DRA NA E CW COLD WATER CALC LAT ONS ® FLEXIBLE CONNECTION D DRAIN F XT RE ANT T TA LE DET DOMESTIC EXPANSION TANK FCO FLOOR CLEANOUT PR ATE P L C P L C PR ATE P L C P L C TOTAL NO 0 AL ENERAL EA SE ND D AL ENERAL EA - SE F XT RE DFU DRAINAGE FIXTURE UNIT FD FLOOR DRAIN 0 ELL N SE ASSEM L DESCR PT ON D ELL N SE ASSEM L NTS ® - O 2 0 FLOOR DRAIN,EMERGENCY 0.00 0.00 0.00 0.00 DIA DIAMETER FS 0 7 0 LAVATORY,SINGLE 1.00 1.00 1.00 7.00 _ ® - FLOOR SINK 0 3 0 URINAL,0.125 GPF 2.00 2.00 5.00 8.00 DN DOWN 0 7 0 WATER CLOSET,1.28 GPF,GRAVITY TANK 3.40 4.00 6.00 28.00 OW DISHWASHER,DOMESTIC WATER is FLOW DIRECTION TOTAL 41.00 PIPE SIZE 4" DWV DRAINAGE,WASTE AND VENT `T {� FLOW SWITCH EL ELEVATION II HOSE BIBB/WALL HYDRANT ELECT ELECTRICAL REASE ASTE DRA NA E FCO FLOOR CLEANOUT 3 PIPE DROP CALC LAT O N S ED FLOOR DRAIN O PIPE RISE F XT RE ANT T TA LE - PR ATE P L C P L C PR ATE P L C P L C TOTAL FFE FINISHED FLOOR ELEVATION A ND D AL ENERAL EA SE ND D Al. ENERAL EA • SE F XT RE (}}' PRESSURE GAUGE WITH COCK D ELL N SE ASSEM L DESCR PT ON D ELL N SE ASSEM L N TS FS FLOOR SINK,FLOW SWITCH O 34 0 RECEPTOR,IND.WASTE,3"TRAP 0.00 4.00 4.00 136.00 _ GAL GALLONS ( PUMP 0 1 0 SERVICE SINK OR MOP BASIN,3'TRAP 0.00 3.00 0.00 3.00 O 11 _ 0 SINK,GENERAL,1 1/2'TRAP 2.00 3.00 3.00 33.00 GPH GALLONS PER HOUR ( SHOCK ABSORBER/WATER HAMMER ARRESTOR TOTAL 172.00 GPM GALLONS PER MINUTE PIPE SIZE 4' 1500 GALLON GREASE INTERCEPTOR GW GREASE WASTE Ni STRAINER GWH GAS WATER HEATER T P RELIEF VALVE WITH PIPE TO DRAIN HS HAND SINK AS CALC LAT ONS Q TEE DOWN ON PIPE ' NO OF T R TOTAL HTG HEATING F XT RE DESCR PT ON F XT NP T T R HVAC HEATING,VENTILATING AND AIR CONDITIONING O TEE UP ON PIPE TC EN E PMENT 41 WOK RANGE 1 240,000 240,000 HW HOT WATER 4 TEMPERATURE SENSOR 42 FRYER 2 110,000 220,000 43 WOK RANGE i 625,000 625,000 HWFU HOT WATER FIXTURE UNIT 68 STEAMER RANGE 1 130,000 130,000 Tri TEST PORT 71 NOODLE COOKER 1 110,000 110,000 HWR HOT WATER RETURN 73 NOODLE COOKER 1 110,000 110,000 t7 92 80 GALLON TILT KETTLE 1 150,000 150,000 HWS HOT WATER SUPPLY LTI THERMOMETER 94 WOK RANGE 1 274,000 274,000 95 DOUBLE STOCKPOT RANGE 1 220,000 220,000 INV INVERT ELEVATION 96 RICE COOKER 2 35.000 70,000 T•p TRAP PRIMER MANIFOLD 99 COMBI.OVEN 1 336,000 336,000 1W INDIRECT WASTE 124 WOK STEAMER RANGE 1 390,000 390,000 ?"�Ep INE"e � acs4�GINfFAPspy29 ' L LAVATORY 9 UNION MEG AN CAL E PMENT il„ 4. 41i /� AC-1 AIR HANDLING UNIT 1 75,000 75,000 • ; OREGON MBH THOUSAND BTU'S PER HOUR 4 VACUUM RELIEF AC-2 AIR HANDLING UNIT 1 150,000 150,000 I.• AC-3 AIR HANDLING UNIT 1 150,000 150,000 �jns5 4P MIN MINIMUM VTR AC-4 AIR HANDLING UNIT 1 120,000 120,000 4- IMC-" gip': VENT THROUGH ROOF AC-5 AIR HANDLING UNIT 1 150,000 150,000 EXPIRES: 12/31/18 MS MOP SINK MAU-1 MAKE-UP AIR UNIT 1 514,000 514,000 WCO MAU-2 MAKE-UP AIR UNIT 1 257,000 257,000 I WALL CLEANOUT MW MAKE-UP WATER MAU-3 MAKE-UP AIR UNIT 1 118,000 118.000 � � Ding Tai Fung MX MIXING VALVE Washington Square Road N NORTH Pi ing S to PLM N E PMENT Square GWH-1 DOMESTIC WATER HEATER 1 199,000 199,000 Tigard,OR 97223 NC NORMALLY CLOSED ---°+-140°HW- 140'HOT WATER PIPING TOTAL DEMAND T 4,608,000 TOTAL DEMAND CF 4,608 NTS NOT TO SCALE -----14011WR- 140'HOT WATER RETURN PIPING P PLUMBING,PUMP SIZING BASED ON 2014 OREGON MECHANICAL SPECIALTY CODE ..�,.� COLD WATER PIPING 2 PSI SUPPLY PRESSURE WITH 1.0 PSI PRESSURE DROP 395 FEET DEVELOPED LENGTH PLBG PLUMBING POC POINT OF CONNECTION D CONDENSATE!INDIRECT DRAIN PIPING 3' 13,500 CFH 2-12" 7,640 CFH QTY QUANTITY 2" 4,790 CFH ,.•.,.....GV-----. GAS VENT PIPING 1 1/2' 2,490 CFH RPBP REDUCED PRESSURE BACKFLOW PREVENTER 1 1/4' 1,660 CFH T 809 CFH S,SK SINK +isSW GREASE WASTE ABOVE GRADE OR FINISHED FLOOR 3/4' 452 CFH 12' 216 CFH SAN SANITARY .„...,,.,.GW"..- GREASE WASTE BELOW GRADE OR FINISHED FLOOR date: description: SOV SHUT OFF VALVE r.,..,.�� HOT WATER PIPING SS SERVICE SINK T P TEMPERATURE AND PRESSURE .. HOT WATER RETURN PIPING TEMP TEMPERATURE 2G NATURAL GAS PIPING,2 LB TP TRAP PRIMER,TOTAL PRESSURE "..�....PD., PUMPED DISCHARGE TYP TYPICAL U,UR URINAL .,-,.,.,.•".-........ SANITARY VENT PIPING VTR VENT THRU ROOF SANITARY WASTE OR SOIL PIPING ABOVE GRADE OR FINISHED W/ WITH FLOORF- W/O WITHOUT -_w. SANITARY WASTE OR SOIL PIPING BELOW GRADE OR FINISHED W FLOOR CO WASTE TP TRAP PRIMER PIPING C 1 WC WATER COLUMN t WC WATER COLUMN,WATER CLOSET a e W WCO WALL CLEANOUT -CD BACKFLOW PREVENTER WHA WATER HAMMER ARRESTORLIJ WSFU WATER SUPPLY FIXTURE UNIT © BACKWATER VALVE S E ET N D EX 0 av BALANCING VALVE P0.0 SYMBOLS UST AND GENERAL NOTES-PLUMBING enera X GPM P0.1 SCHEDULES-PLUMBING date: P0.2 SPECIFICATIONS-PLUMBING CHECK VALVE P0.3 SPECIFICATIONS-PLUMBING ..-.X.-X- DEMOLISH PO.4 SPECIFICATIONS-FIRE SUPPRESSION P1.0 FLOOR PLAN-DEMO-PLUMBING 147 EARTHQUAKE GAS VALVE P2.0 UNDERGROUND PLAN-PLUMBING EXISTING WORK P2.1 FLOOR PIAN-WATER AND GAS P2.2 FLOOR PLAN-WASTE AND VENT drawing title NEW WORK Pal HOSE END DRAIN VALVE P3.0 ROOF PLAN-PLUMBING S MB LS LIST AND P5.0 DETAILS-PLUMBING GENE AL N TES- PLUMBING number PO.0 FILE: 0046-POO.DWG - PDO 1 EDIT: 4/26/2018 3:20 PM BY TODOS 1 PLOT: 4/27/2018 11:37 AM BY HUONG NGUYEN TC EN PL M N SC ED LEIEOU�MBIEN1 WATER HEATER SCHEDULE CLR SUPPLIER DESCRIPTION MANUFACTURER PLUMBING MODEL NUMBER o CAPACITY BASIS OF DESIGN TANK GAS DATA. ELECTRICAL tu Z w CC Z p Z SYMBOL. EQUIPMENT TYPE LOCATION/SERVING MFR MODEL (GALLONS) INPUT(CFH) VOLTS PH AMPS KW COMMENTS Chin /R.eche WU . 1— _. U) U) p M GWH-1 GAS WATER HEATER STORAGE RM 108 A.O.SMITH STH-199 100 199 120 1 15 PROVIDE VENT KIT 100111100 AND CONDENSATE W (3 �i O 0 Q Q F- Ui ' 1= Y 0 0 CS z t- 0 m ' _ :IN NIT _ ..___ 1— NEUTRALIZATION KIT 100112380. 1516 Melrose Ave.,Suite 200 liMill SOILED b15HTABLE WI4 SINKS PACIFIC-CUSTOM FS 1) AN. {N ,(3)SO•K Si K . Seattle,Washigton 98122 4 ►Z41 3 FAUCET T&S B-0228 1/2' 112' 4 - 206 9381501 5 ►= 1 SCRAPPER SALVADOR P914 3/4' 3/4' 2' 5 NOTES: 1 PRE-RINSE FAUCET.-- T&S 8 _-0133.3 - 1/2' 112' • 7 CO _. 8 = 1 CONVEYOR DISH MACHINE :BY OWNER 1/2' FS VERIFY REQ. 8 CO 13 r41 3 FLOOR TROUGH PACIFIC_FT7212-5G 3' 13 14 �� 1 HOSE REEL T&S B-1433 32-01M 1/2' 1/2' 14 "t�' U. ., 15 , 1 MOP SINKLTYr ARSB-0650CE STR 2' 16 MISCELLANEOUS EQUIPMENT SCHEDULE 16 ►�� 1 UTILITY FAUCET T&S B-00665 12' 1/2' 16 W 20 ► 1 3-COMPA4TMENT INK ADVANCE 94-23-60-24RL FS 20 21 "'A 1 PRE-RINSE FAUCET WI ADD-ON FAUCET T&S 8-0133-61-CR 1/2" 112" 21 Z 22 Ir- 1 FAUCET 'T&S B-0231 1/2' 1/2" 22 BASIS OF DESIGN GAS DATA ELECTRICAL w 25 MI 1 H�SINK I.ADVANCE 7-PS-20 1-1/2' 25 INPUT 26 ► 1 HAND SINKT I ADV B-11NCE 1/2' 112' 26 SYMBOL EQUIPMENT TYPE LOCATION!SERVING MFR MODEL CAPACITY (MBH)- VOLTS PH AMPS WATTS HP COMMENTS 8 28 lea 1 HAND I ADVANCE 7-PS-20 1-1/2' 28la 29 M 1 FAUCET T&S 8-1141 1/2' 1/2' 29 TP-1 a,TP-1 TRAP PRIMER WOMENS RR 110,SCULLERY RM PRECISION PLUMBING MP-500 120 1 2 6.3 — CONTROLLER INCLUDES CIRCUIT BREAKER,MANUAL s S 41 ,Gni 1 WOK RANGE WI FAUCETS PRODUCTS SWITCH,AND TIME CLOCK SERVES 1 T04 DRAINS. i At TOWN M-2-SS-N 112" F$ 1-114' 24DK 41 � e 42 Iii 2 FRYER PITCO SG14-S - 3/4* 110K 42 0 1 h € 43 ;re 1 WOK RANGE WIFAUa-TS TOWN M 5-$S N 12" FS 1.114" 625K 43 TP-2a,TP-2 TRAP PRIMER BEVERAGE AREA,NOODLE STATION PRECISION PLUMBING 'PRIME-TIME" - 120 1 2 11.5 — CONTROLLER INCLUDES CIRCUIT BREAKER,MANUAL `r 1. ` o 46 NMI 2 HAND SINK WELD-IN INCLUDED IN ITEM#48' 1.112' 46 TP-2c47 ,TP-2d AREA,DUMPLING ROOM 101,BAR 103 PRODUCTS (SERIES PT) SWITCH,AND TIME CLOCK. SERVES 4 TO 30 DRAINS. '- " 1 S 47 irlb 2 FAUCET T&S 49 ►t 1 REFRIGERATED PREP TABLE CUSTOM 41 1/2' 1/2' FS - 49 E 8 m d Z 1 51 e 1 U/C REFRIGERATED DRAWER •CUSTOM • FS 51 & 8 in a I--U. 54 ,07.:14 1 DBL OVERHEAD PASS SHELF CUSTOM 54 - . 55 ► 1 3-BAY H07 FOOD WELL WELLS MOD-300TDM/AF 1/4' - FS 55 - 59 ►t 1 U/C REF`W/1 DOOR&2 DRAWER SECTIONS CUSTOM FS 59 NOTES: 68 ►Z-4 1 STEAMER RANGE&CABINET BY OWNER 112° FS 314' 130K VERIFY REQ. 68 69 { 1 WALL-MOUNTREFRIGERATOR OMNI-TEAM-CHR-1GL-AS-PP FS 69 71 ® 1 NO )LE COOKER W/FAUCET -OY OWNER 112" 314" ' VERIFY REQ. 71 721 1 HO FOOOD CCABBIINEE'TTBASE STOM STAINLESS AF ,14• FS 721 PL M N F XT RE SC ED LE 73 1 NOODLE COOKER W/FAUCET BY OWNER 1/2" 3/4" VERIFY REQ. 73 . 75 ►� 1 FREEZER EQ BASE DELHELD 12776 FS 75 - BASIS OF DESIGN CONNECTION 80 ► i WORK TABLE WITH SINK PACIFIC-CUSTOM(30X54) FS - 80 SYMBOL FIXTURE TYPE DESCRIPTION MFR MODEL ACCESSORIES W V CW HW NOTES 81 kr. S FAUCET T&S 6-0221 1/2' 1/2" 81 FD-1 FLOOR DRAIN CAST IRON BODY,FLASHING COLLAR, R SMITH 2005Y- 3" 1-1/2" PRIMER CONN. - 83r►f 1 HAND SINK ADVANCE 7-PS-20 1-112' 83 (FINISHED FLOORS I 6-INCH AD USTABLE NICKEL BRONZE A-06- 84 *MI 1 FAUCET 7&S 8-1141 1/2' 112 84 SHOWERS) STRAINER HEAD,TRAP PRIMER, P050-U-NB 92 ► ' 1 80 GAL TILT KETTLE W/FAUCET GREEN DHT-80 1/2" FT 1/2" 150K -W/TANGENT DRAW-OFF VALVE 92 VANDAL PROOF TOP 93 ►i 1 FLOOR TROUGH PACIFIC F'824-SU` 3' 93 94 ► 1 WOK RANGE W(FAUCET TOWN Y-2-SS - 1/2' FS 1-1/4' 274K 94 95 7E4 • 1 DBL STOCKPOT RANGE - VULCAN VSP200F 3/4' ' 220K 95 FD-2 FLOOR()RAIN CAST IRON BODY,FLASHING COLLAR, R SMITH 2350Y- 3" 1-1/2" PRIMER CONN. 96 2 RICE COOKER SY OWNEi 3/4' 35K UTILITIES PER EACH UNIT.(X2) 96 (UNFINISHED FLOORS 18-1/2-INCH ROUND AD USTABLE TOP, P050 99 1 COMB;OVEN RATIONAL.SCC WE'202NG (2)3/4' ES 3/4' 336K 99 MECHANICAL ROOMS) BAR GRATE,SEDIMENT BUCKET, 105 ► 3 COOLER EVAPORATOR COIL 'INCLUDED IN ITEM#200' FS 105 TRAP PRIMER 107 ►;, 1 FREEYI`R EVAPORATOR COIL "INCLUDED IN ITEM/200' FS 101 - 115 ► 1 3•COMPARTMENT SINK ADVANCE FC-3-1824-18RL FS 115 116 II.7.4 2 FAUCET T&S B-0231 1/7 - 1/2' 116 _ 119 ►M 1 HAND SINK W/"KNEE'FAUCET ADVANCE 7-P-90 1/2' 112" 1-1/2' 119 FS-1 FLOOR SINK CAST IRON FLANGED RECEPTOR, R SMITH 3160Y-11 3" 1-1/2' PRIMER CONN. - PROVIDE 1/2 GRATE 120 *MA 1 DROP-IN OST TOP _OMNI-TEAM-CUSTOM FS ' 120 SEEPAGE HOLES,ACID RESISTANT AT ALL FLOOR SINKS 122 Di 1 DROP-IN FROST TOP OMNI-TEAM-CUSTOM FS 122 COATED INTERIOR,NICKEL BRONZE UNLESS OTHERWISE 124 CZ 1 WOK STEAMER RANGE BY OWNER 1)2" FS 1-1/4' - 390K VERIFY REQ. 124 RIM,1/2-GRATE,ALUMINUM DOME NOTED ON KITCHEN 132 1 1-SECTION PASS-THRU REFRIGERATOR 'IDILFIELO-CUSTOM FS 132 BOTTOM STRAINER,10-INCH DEEP DRAWINGS 134 ►� 1 HAND SINK WI"KNEE'FAUCET -ADVANCE 7-PS-90 1/2" ' 1/7 1-1/2' ' 134 1 „ ►.i 1 REFRIGERATED DRAWER DELFIELD-CUSTOM FS 136 139 ►M 1 REACH-IN FREEZER DELFIELD-CUSTOM FS ' - 139 140 t 1 1-COMP SINK ADVANCE 03-21-20 FS 140 140.1 ,r 4 1 FAUCET T&S 8-0231 1/2' 1/2" 140.1 141 ►� 1 - WORK-TOP REFRIGERATOR DELFIELD-CUSTOM FS -141 1-1 LAVATORY WALL MOUNTED,VITREOUS CHINA, KOHLER KINGSTON FAUCET(SINGLE LEVER HANDLE):bELTA 1-1/2" 1-1/2' 1/2' 1/2" 146 10-=4:41 1 COOLER EVAPORATOR COIL INCLUDED IN ITEM#200' FS - - 146 3-HOLE PUNCH,4-INCH CENTERS, K-2005 511 LF-HDF 148 •"". 1 FREEZER EVAPORATOR COIL 'INCLUDED IN ITEM#200' FS 148 FRONT OVERFLOW.WHITE 1 ►i 2 HOT WATER DISPENSER BL50MFIELD 1228-DLX-120 112" 157 160 1‘, :j 2 WATER FILLER&DRIP TRAY T&S 5GF-8P-WS 1/7 • FS 160 161 e1 CARBONATOR BY OTHERS 3/8" T'WATER TO SODA DISPENSER. 161 L-2 LAVATORY UNDERCOUNTER MOUNTED, TOTO LT540G FAUCET(SENSOR-HARDWIRE):SLOAN 1-1/2' 1-1/2" 1/2' 1/2" 162 1 SODA DISPENSER&ICE STATION BY OTHERS 3/8" FS WATER FROM CARBONATOR. 162 VITREOUS CHINA,RECTANGLE 21-1/4" EAF-200-P-ISM- PROVIDE WITH MIXING 163 `Mt 1 DROP-IN HAND SINK ADVANCE 01-1-10-2X 1-1/2' 163 x 14-3/8',FRONT OVERFLOW 01 VALVE. SEE PLUMBING DEVICES SCHEDULE 164 MI 1 FAUCET T&S B-1141 112" 112" ' 164 COTTON COLOR FINISH FOR MIXING VALVE(S), 167 '� 1 DUMP SINK DROP-IN ADVANCE DI-1-10-2X FS 167 168 '► 1 FAUCET -T&S 3-1141 1/2' 1/2' 168 173 ► 1 FAUCET T&S 8-0221 12' 1/2' - 173 UR-1 URINAL WALL MOUNTED,VITREOUS CHINA, TOTO UT105U FLUSH VALVE(BATTERY-0.125 GPF, 2' 1-1/2" • 3/4" - 174 ► 1 REFRIGERATED PREP TABLE DELFIELD 1B672PTBM FS 174 TOP SPUD,FLUSHOMETER, DIAPHRAGM):ZURN ZER6003AV-EWS-CPM 177 1 HOT WATER DISPENSER BLOOMFIELD 1228-0LX-120 111- 177 179 oh. 1 DUMP SINK WELD-IN 'INCLUDED IN ITEM#197' FS 179 STANDARD MOUNTING HEIGHT, 01 180 ► 1 HAND SINK-,WELD-IN INCLUDED IN ITEM#197` 1-1/2' 180 COTTON COLOR FINISH 181 ►�44 1 FAUCET T&S 8-1141 12' tr2" 181 182 ►; 1 FLICE BERIN ICE MACHINE HOSHIZAKI F-5001MRJ•C 117 FS 182 UR-2 URINAL WALL MOUNTED,VITREOUS CHINA, TOTO Uri 05U FLUSH VALVE(BATTERY-0125 GPF, 2" 1-1/2' 3/4" 184 1 ICE BIN BY OWNERSHIZAKI -500SF FS 184 TOP SPUD,FLUSHOMETER,BARRIER DIAPHRAGM):ZURN ZER6003AV-EWS-CPM 184 � 1 COUNTERTOP SHAVED ICE MACHINE BY OWNER VFY WY VERIFY REQ. 184 185 1 1 CRESCENT CUBE ICE MACHINE HOSHIZAKI KM-1900SRH 1/2" FS 185 FREE MOUNTING HEIGHT. 01 -17,56-1,1 1 ICE BIN HOSHIZAKI 8-1300SS ES 186 COTTON COLOR FINISH 192 ► 1 REFRIGERATED PREP TABLE _DELFIELD 18672PTBM FS 192 202 ►Zo 1 COOLER EVAPORATOR COIL 'INCLUDED IN ITEM#200' _ FS 202 208 ► 5 DRAINBOARD GLASS-RACK(121 PERUCK SC12 FS 208 - WC-1 WATER CLOSET TANK TYPE,VITREOUS CHINA, TOTO CST744EL PROVIDE TC TECHNICAL CONCEPT AUTO 3" 2" 1/2" • - 210 111711 2 COCKTAIL STATION TEFILICK TS301C10 FS 210 BARRIER FREE HEIGHT,ELONGATED, FLUSH TC 401813 WIRELESS AND CHROME. 212 ) 2 CARBONATbR BY OTHERS _ • 3 8" ROUTE WATER TO SODA GUN. 212 1.28 GPF 215 J 2 HAND SINK&FAUCET PERLICK TSI2HSN _ 1/2" 1/2' 1-1/2` 215 - 217 E. 1 ROTARYGLASSWASHER BY OWNER 1/2' 1/2" FS VERIFY REQ. 217 NOTES: 218 1 U/C GLASSWASHER BY OWNER 1/2' WY FS VERIFY REQ. 218 1 SEE ARCHITECTURAL DRAWINGS FOR ALL FIXTURE MOUNTING HEIGHTS AND LOCATIONS. 219 0331 2 DUMP SINK&FAUCET PERLICK TSDI2HS i2" 112' �S 219 UNLESS NOTED OTHERWISE ON DRAWINGS 223 r� 2 HOT WATER DISPENSER BI.00MFIELD 1228-DLX-120 12° 223 224 ►Rf - 1 3-$bORBACK BAR COOLER&TAPS PERUCK BBR72 " FS DP,AJN bR/P TRAY TO VS. 224 226 R`�,� 1 9-DOOR BACK BAR COOLER PERLICK BBR72 FS 226 228 ►.a 1 2-DOOR BACK BAR COOLER PERUCK 88R48 FS - 228 PL M N DE CES SC ED LE REFER TO FOOD SERVICE CONSULTANT'S DRAWINGS FOR KITCHEN FIXTURE/EQUIPMENT CONNECTION SIZES AND LOCATIONS. 3ASIS OF DESIGN CONNECTION SYMBOL FIXTURE TYPE DESCRIPTION MFR MODEL ACCESSORIES W V CW HW NOTES DET-1 DOMESTIC WATER 4.4 GALLON CAPACITY,WELDED AMTROL ST-12 — --- 3/4" — EXPANSION TANK" STEEL CONSTRUCTION,DIAPHRAGM THERM-X-TROL IAPMO TYPE,SEPARATE WATER RESERVOIR, PRE-PRESSURIZED,IAPMO CERTIFIED. LV-1 SINGLE FAUCET POINT-OF-USE MIXING VALVE,ASSE ACORN ST70 — — 1/2" 1/2" - MIXING VALVE 1070 COMPLIANT,INTEGRAL CHECK CONTROLS VALVES.LEAD FREE NOTES: EP.0 PROP Uri` 8G4NfF 'b 84929 1, . • i. 'ie' 19, OREGON A/, McC4 'EXPIRES: 12/31/18 I project title: Ding Tai Fling Washington Square 9677 SW Washington Square Road Tigard,OR 97223 crate: description: F- Cr)C z CO w a data: drawing-title S EDULES-PLUMBING number -. P0. 1 - FILE: 0046-P01.DWG - P01 I EDIT: 4/26/2018 2:23 PM BY TODD'S I PLOT: 4/27/2018 11:37 AM BY HUONG NGUYEN T T 1 CLR # I I 0 chin-Ley/Reche 1516 Melrose Ave.,Suite 200 I I 1 REMOVE ALL PLUMBING FIXTURES IN THIS SPACE AND CAP WATER,WASTE AND Seattle,Washigton 98122 VENT PIPING BELOW GRADE AND/OR IN CEILING SPACE. ::206 938 1501 Wd !�r p - - - - - - - - — — — — - - - - - - p Y ro I # =os zz o 0 2 3 T GENERAL SHEET NOTES CLR A. GREASE INTERCEPTOR IS LOCATED OUTSIDE AT THE LOADING DOCK. 4 I Chiu-Ley/Reche r� 1516 Melrose Ave.,Suite 200 �' lSeattle,Wastugton 99122 `-� 1 11 I I 206 938 1501 I US 0 FS 4'VPTO B...• ; FCO ee 2'V VP S=2% -` 3•- --�•.GW i _I 4• zO El - V - E --. EGO - y I - - - Z X l 4' GW4"�� I �, E =2..x7-.—,..r,— m $ All g� t 01:* n r' r `r �i o 8 F.q G 6 f5� $ . ,N,a" 1 /� 0 3 Fs g.- mt 2"--1-3--0 ;,..---2"V UP FS -2" f f © ---,---,---,,---/- .. . 81205. i a, 6"PVC BEER SLEEVE / Ifi.--j.............,;:..,.•4'UP TU g / I FCO1 C�..-��r-rrr_ .. �- -----,-- ----�_- ///-----_-r-w----------------... «-r.-..» �.«_ - '' I f f 0-... ........ ....3-. 1 :f 111 FS F3' FS f/ I FSf I 2'VUP 1 /1' Q-3' f I I ✓� t 0 ------•-3' GW 3• /f N B'PVC SODA SLEEVE Ark FS FS FS 4-3' / V 3"-0 2"VUP O— 3• / I I F3 I /•/ n^ /-x�-- I--a�--•# — — — - - - - — — — — / — — �� — `-i — — — — kJ 1.t�3" FS 2'V UP FS 1 �f/ 8'PVC SODA SLEEVE / ° -'"�NNNNI 3 %/ / — I A' r I /f/ 4"UP 70 / / FCO / 4").:' i 1 - IE=2'-0'6FF ,.�f I I / f/;. / �4" G W //+ /.'/ / 4'O TO '� EGO �/ f�f / /,/ I I 2'VUP 2' •I® I //:;::::. j fJ 'v o- 3" •II Gw 3" /, f f Fs T / e" .0" FS f,/ /r D-3" 7,/ :,r FS 1, 3." 0 FS /,/ /.f 53 ( c } - - - - - - - - - 1J f 2 - - - - - 1:111 - - - [ - - - ��•• ;`PVC SODA SLEEVE ' 2'VUP I V:(7"97...7. � cr3" • I ' ` s // � 0 4'UP TO ® i ' f'� I tI FCC /',./ I I Fs I 1 / / �� I N 3•...n . r rn I t ..... ii /ro I 0---•3' 0 i✓S I 111 © I II I 3'.ElS 2'V UPMEWS — ® 4"UP TO reimmoNL� - - - - - L j - -... 7 - - - FCC _ dmanniming 41m• 7......_.,„„ _ I . . 9 2'VUP 4"UPTO if OREGON 3'WUPTO ® FCO y. TROUGH FS -,-GW q t`r'y WO- PROVIDED I FS I� , f BY OTHERS 111 EXPIRES: 12/31/18 © 2'VUP i S o project titie: Z.) FS Ding Tal Fungi Washington are FS I 9677 SW Washington Square Road 0. 3" Tigard,OR 97223 >. F I 2'V UP 3" I 3'W UP TO 3"WUPTO TROUGH TROUGH 1 PROVIDED PROVIDED BY BY OTHERSOTHERS © - o o , - _ _ - - - � - _ , _ I I I I 3"G W I 3"—.-N:13"W UP TO- date: description:N TROUGH N PROVIDED BY OTHERS I FS 1:1 1<s F 4'UPTO —Gyy S FCO r 2"VUP 71L- , 3-'--- ____, , 2'VUP1:L...41 . .® 2'V>IP 3".GW.+^r I I 3•� FCOTO FCO Q� Ei 0 - - R UR LLI - - ❑ � - __ y - r 11 � i- G I❑ CO ❑ 2' ,I r ----r ziv - L I 1 4"UPTO 2. II UPTO I 4''UF,TO FCO �S=2% FCO FCO 111f...////J,♦� ji = esiara:1 _.. ...... 4• r..-"..�.. 7_74" J1Jq 1 i 2"VUP I �/ �4'SANITARY SEWER�2% m�FD � FD� :Tr.' LATERAL R E `y G - ❑ - - I Wo ® - 41 DFU - - ❑ ® © - 1Mil ,7 ika___,, jcs_ FS - - - - - ______I l date: 0 ❑ Di 2"VUP 2'VUP 2'VUP I I 1 4'UP TO 4"GREASE WASTE 2% I COTG 'LATERAL#1 drawing tide 172 DFU IE=6-9'BFF UNDERGROUND PLAN- PLUMBING N il NIli "i UNDERGROUND PLAN — PLUMBING '. 0 2' 4' a' number iiiiiel SCALE:t14"=1'-0" P2.0 - FILE: 0046-P20.DWG - P20 I EDIT: 4/30/2018 8:54 AM BY TODDS I PLOT: 4/30/2018 8:54 AM BY TODD SHOOTE I ® 3 0S EET E NOTES CLR (E)2-112'CW VERI 2-t12'CW,101 WSFU PRVALVE VIDE 2-112•MAIN SHUT-OFF I 1 ROUTE 1-112'NATURAL GAS PIPING DOWN ALONG HOOD FOR CONNECTION TO EXACT LOCATION •68 GPM PEAK LOAD VALVE AT EYE LEVEL WITH ACCESS WITH LANDLORD I PANEL.COORDINATE EXACT LOCATION NATURAL GAS SOLENOID VALVE AND NATURAL GAS REGULATOR AS HIGH AS Chin-Ley/Reche WITH ARCH.AND LANDLORD POSSIBLE BELOW CEILING.ROUTE 1-112'NATURAL GAS FROM GAS PRESSURE J, I, III _-.ii♦1 REGULATOR FOR CONNECTION TO GAS FIRED EQUIPMENT.INTERTIE TO HOOD FIRE 1516 Melrose Ave.,Suite 200 Seattle,Was n 98122 y ,ipp,A; _ V ■___r r �`>✓� �. re SUPPRESSION SYSTEM. 206 938 501 ", 2 ROUTE HOT AND/OR COLD WATER DOWN TO BELOW GRADE THEN BACK UP UNDER , IF314'CODE APPROVED r—��Jl 1-114"---}� �--..-L-71-1/4" �- -� - ----------140.11w------_--.... - --1-114'— _ - II I COUNTER FOR CONNECTION TO KITCHEN EQUIPMENT. �0 I F �.I - Ir 1.114•_ I --L -- __ -" __-- __ i-114' -- Cli 3 1'CW DOWN WALL,ROUTE LOW ALONG WALL FOR CONNECTION TO KITCHEN '�BACKFLOW PREVENTER -- -r- — - 1 EQUIPMENT. 0.u. El MS 2 — 314" 1 ! I r 1-112" 140°HW f 1-112" r I T I _ 4 314'CW UP TO MECHANICAL EQUIPMENT.SEE 11P3.0 FOR CONTINUATION. kly e r 'v DUMPLING.ROOM �� I _ �uIl ul , �y - - z . I I -'- ' (E)LV-1 101 TP-2c I 2•G UP TO ROOF 114111111 i E 11i2'0 - 2'G • ENTRY LINESSTUBPVC SODA 'ifJ.u111� 'lr, III 2 i a I - t I: 1-1/4'CWDN 42 Ill, iD C'} li , J 100 �'tt��l� ..I y m .*g ig s u— —. lug iii $i I I �. 2'3 i�r�.r1 ,2_/. • $R1� III` © O O VI Oro N N '' I�Ii:l���■E 'r.I:rA P N F m LV-1 ¢ - I I ® IIS: II 13 �� t-114"HW E i 1 �� Hh1I' . iFROM BELOW , u kt 49 / 6 PVC BEER IMAM = ---_ all ru • LINES STUB � I 1 BAR 11 6"PVC BEER LINES STUB I I 'I 103 711 r ______Ieff1 riIHi' _ 390-C H 1 11�I I �I„,:, mitill ii--,,,, " I r '05- CO HOST Ilr,�l��l e 3 1!fll!■ i ';'' P5.0 F �. ® Ii MIN s I Ie-ii 114 tIl1 I ni ti , I rii. lilll - Q 1-1/THW DN LV-1® _.1I-_,.. iral 1111111111 kr ill { B ) - r - ---1I I t- - JUH —I 11- Iii-'/ - - - - - - `J - '�; y - - • I I I �I I \ ® II�Bi2� i IF L 'ill = — �- 314"BP I. rt, I ate", 1'I,„.„,. 223 I1 rI 1 I � La 1 I 0 l - • 6'PVC SODA f LINES STUB i 1•G $ ,I 140°HW_ - ____2.-- 2' ..!. . 0—1 i _ I - 314'BP— I1'171 1 I�( iS4 112' I A, 3 I ivi a 130 GFH I II lM4 168 1t2 m I1 o , ' A1 L , . 1 1_ LI I (190 10 I � i I . 112' 240CFHQ 'il���R_ 1110 0 I[OOO IiL,_ 1 .11 il 112' _ _ lel 1 14111:7.4i1 u171�.1 1r2. wI � �'L - f r _ - ,11-011,111 =--• 1111 40112" LJ - - - - - - COI 2 110® Il ® i•i i il-- 112• 1ilt i. 1'I� 6" VC SODA }rn rat - - - - CFH EA Ill - . ® - ^-_ LINES STUB CEP i1 1 CA in- - n- I 1�0 I I � � ,L j.. r , iito %I i. I ❑ ! CD 112" O i■ i I j""� II � 1 . Ftp ■IOOTOjI1 112" I J i 1 iii II I!� I I 1 1 I DINING DINING • tel-- a E 6'PVC SODA 104 I 0 •iii I mIII I IR I I I LINES STUB 1 r I■Ni>1!5 3 � 0 I� ; ®1 �c I l' 625CFH� Ilir d_4'.-_-1 �1 •. Er r ' I I.. I �l TP-2a 1 ,,• 1 to° ..,.....\\71/2" I1 336CFH0 ■; ��� iv - - 314'BP - - 2 35 it �,1 N 0 w CFH EA.O ' � LV-1 0 i?� ' I Q 220CFH© I • • I a_kii FUl1 I -D — _ G1 ■ 1 I ID IIKTIIM o I I11 I��'IM I 64929 iiiii � I, 1 dillIr -� LemilllidiLlq. , �i12' Jr OfICOr1 CI • G L__ I,I ,:ail Willi Go 7 112•- 9 5tipt Pg AI -i••• .id iiir 4 \ -P / EXPIRES: 12/31/18 � ,,, II F,p- LV-1 Q 1'O , �.1""� 11_ii - _ ■■ 1• yt � r — i►` Iv thic 1150 CFH/2'CW 0 Ill 112'tQ 1 , I DngTa Fung ,131 I 274 CFHO w ° ° I 9677Washington Square 9677 SW Washington Square Road 0112' Tigard,OR 97223 N ' 1. 'I 1. I Z. PRIVATE DINIrIG I �_ t07 DINING © - ❑ - - ❑ - - - - - 11 IrCD l.04' -e - - Illn 1.1 - - - _ los - - - - 1 � Al l ' ; 1 r I Dr [V I date: deecxlption: r I TP-1 X112' 3141 1f2' 1 , = 71r- 16 al .4 1-112' 01 -- FR '', � 1 l I���i ,_--- 6 rff- ` — LV-1 V7 0 I -® -1 - _- L_i � UR-1 UR-1 UR-2 PLOYEE RR r.1=�iw r-- ion aseat �� �lV 1 - 1-1f2" STORAGE 314•GUPTOROOF TP-1a 108 l I -1V 1 lv _ OMNI j� zA I WOMEN'Skr iBOATHROOM RMEN'S BATHROOMA� ®ic `� LV 1 t. �\ l v� I I . . -----2-_—_ ■ �, - 2'-- •' 2' r — 2- — CO�OET-1-1 c_ EMPLOYEE RR LL2 L_2 L-2 Jn1/Gin-01 4— 112 1 G1 - - _wc i LV-1 4• LV-1 r°HWR LV-1 —L——1 / ,— 314" 0 ( 1� 2.-4_ ■■P•7 ■)1 140 HW I Iwo! II .■INA 2' '�I L_II - - - - - © - - .'.11- WC1 - - 711° ❑ --Ran liarimal �• 1" 1` �—� r4� Tzs� - 4� r. MMO MEP 1-114• -411111 3/4"DN 3/4 ON 314'DN 12'DN 112•0N 3/4'DN I drawing title L PLAN- ATE AND GAS N Ak 1 FLOOR PLAN - ATER AND AS " 0 2' 4• a• number liliil SCALE:114' 1'-0' P2. 1 �` FILE: 0046—P21.DWG — P21 I EDIT: 4/27/2018 9:30 AM BY HUONGN I PLOT: 4/27/2018 11:38 AM BY HUONG NGUYEN 1 2 T CLR I O SHEET KEYNOTES Chin-Ley/Reche I 1 1-114"DRAIN LINE FROM MAKE-UP AIR UNITS.SEE 11P3.0 FOR CONTINUATION. --1 ®13 - H ...4.__.--, 1516 Melrose Ave.,Suite 200 -� �, ;f �I �� 1 Seattle, 60n t88,22 I 4os o - 9 _ I -1:10-1:10I C FS-1 I I I I I 6•PVC SODA I d Z FS 1 I I FCO I II LINES STUB '" ig- ��� _ I z Isjr.(c2-7 L L __ f - 1—0 0 ® DUTAPLI10 ROOM I '�� I FCO ' A I E N 1 II 8 11 L _ c_iii_ji_ �ENTRY f E[�IjN IIIA■ !� !AIR N �i 10 I J 1I iro I c! ' I I lr■IJ ®� I �.' °_E I 1'�— �°FS-1 s w�a �I►�—ii Ir L J Eibli3!4 i O 6PVCBEER• i BAR LIES BEER 314"D I I 103 ' I LINES STUB Hf a Q r"EMI ..__ I, T I r�� 1 r 0�FS-1 gi a '/�i l:: �FS1 ,;I ,82 183 r`I ..i„- } !arm- �2'VTR IF �_ �i ...... � 1"/ 1 I 477;7i-11r r �1 Et HOST i,VIII i II •....FS-1 102 1', lE.�II ill Hip FS-1(Die ■ I� 11 , R ��I 179 FS-1 +�i®. 1 f II I � 1 ISI I P5.0 fli1I 1r.`.1rFS1JLk IIll I: kgi Go iII 1 / IFL 1.1l4'1 © mu Iw,`u�.r I , II I ® E I ® I r 1Li 6'PVC SODA LINES STUB EDO 1-11a•� Q I FCO D FS-1 COW FS-1 i — S // _��2.1.�ri IlC i ii, AIM' ' F51 It �jIIIL11 ON. 1 FS-1 I 1)tI_L” Ir. I � -I I'r-=1� llf.5 I I 008011 1,0111 , r�;w ^ - - - - - - �"J FS-1 li�"�■■ aillutu n ,,i I II I I II�I llf ' Bra®moi Imam i II�� I I i ; I, ,■I " n, 7 ►I,■ ,_-1_-_--- 2--i 6'PVC SODA FS-1 �I� �� ; nilLINES STUB 01-1 wii .. .. ck_li ) 1I FS-1 Q� ) oIIIiiTi 411.1 / j I___ � I 000 I II III I 1.�1 I FCOiii DINING DINING FS-1 11 4 --vm I I�� 2"VTR 104 105 IW m 111 .0IME11111 II 11- - , I n' - - .Z. [! I' ■I iE of 11 1 -. Zt 6"PVC SODA €.7. •,1 C� • _ r.'��: -,, j IM LINES STUB 0.4040 r— I yD 0 .� FS-1 co I I . Pi :. 1.114• . 41 rx--71 ' .1L-2 l'A. A .‘ al ( p — Yv — ! ■ — o — �w�l�E —smappoprL1] — — — — — — `J — — — — — iii i ll �1 c FS-1 o_ql7. o,g I 00 -1 low w, • b4928 /i / IMO!! ®FS-1 J OREGON �� �� ifl'Il ll� ririFr- , 1E FCO I..� LED �_ii ,- ti_ -2' r!ed -�}� r- �wrri 11 f a prefect title pp KKK IT itil 1��4• ,,, Ding Tel Fling on Square i nyiym e i I 96W77 SW Washington Square Road ♦--O c5 1 L/ . dh` % 1 •li FS-1 Tigard,OR 97223 J F- O . NI I°,1 I 11111 PRIVATE PINING IJ 107 DINING 2-VTR I 314' ci ,� 1.-----2.w.�0 13 xi date: description: , I 314• 00I . ,a ER.: 4r`e I ] �- 'a II®MS 1 O I Li FS-10,11 - 9�1 C-1 1 - �CO LN I 1 EMPLOYEE RR _ 111 O - - - - - F - - - - UR-1 UR-1 UR-2 - - - - - (71 .11 1��1 l _ =lifl=11.. -I -2"�' I 1 - STORAGE i N �LT1 I TR L-2 L-2 I WOMEN'S BATHROOM MEN'S BATHROOM Z I 3•Vw 1 r R 110 1 I 109 108 tD.FCO ` - - FCO` �` I _ � FCO CO r 2-10_, I 0 / 0 "' EMPLOYEE RR // L-2 L 2 L-2 FD-10 / LL! WC-1 112 WC-1 --VC/64 . WC-1 -- — ✓WGt J�WG1 _ _ _ G 1 .� " FS-1 0 / r — .� �.... _� - date t OTG I drawing title FLOOR PLAN-WASTE AND VENT N N1 FLOOR PLAN - WASTE AND VENT lir 0 2' 4' 8' number iiniaTn SCALE:114'-1'-0' P2.2 FILE: 0048-P22-DWG - P22 I EDIT: 4/30/2018 8:49 AM BY TODDS I PLOT: 4/30/2018 8:50 AM BY TODD SHOOTE . T I T ENERAL S EET NOTES A. PROVIDE MIRO 5-RAH-7 ROLLER PIPE SUPPORTS FOR THE GAS SERVICE AT TEN FOOT INTERVALS AND WITHIN 2-FEET OF A CHANGE IN DIRECTION. SUPPORTS TO INCLUDE A r x 15.25"SUPPORT PAD AND MIRO 5-RAH PIPE GUIDES. CLR 0 S EET E NOTES Chin-Ley/Reche 1516 moose Ave.,Suite 200 Seattle,Washigton 98122 1 PROVIDE CONDENSATE TRAP AT HVAC EQUIPMENT PER MANUFACTURER'S 206 938 1501 RECOMMENDATION AND DAYLIGHT DISCHARGE TO SPLASHBLOCK 2 3/4"CW AND 1-1/4"DRAIN LINE CONNECTIONS,SEE KITCHEN CONSULTANT II0 0 I DRAWINGS FOR EXACT CONNECTION REQUIREMENTS. U Z 4; 10.NA eV" 0 — — rovrn — Z.*. ROUTE 2"GAS DN INTO CEILING SPACE lii IW 8 ei 6* 1 I IT, S 0E4 ig 74,v,Pa 9 elef`t 0 i 1 01253 fIlIe 2 I Is, 2"VTR AC-4 120 CFH \ 0 I 0 7-3/4"G AC-1 Alli 75CFI-1 SEE 1/P2.2 FOR Ark CONTINUATION lig - • ' E • f 3/4G--. I I 3/4'G l _ _ _ E i\\ 3 I ® e 4:1 0 , 0 P5.0 1"G MAU-3 to 118 CFH . Ark SEE 1/P2.2 FOR CV CONTINUATION • • 0 \--MALI-1 514 CFH 0 Isi ® _ _ — _ _ _ I 2"VTR 2 PSI NATURAL 0 GAS ROUTED ON ROOF Ank SEE 1/P2.2 FOR CONTINUATION NU • 3/4"G 11111 Elp r En I II AC-2 150 CFH . A NIAU-2 257 CFH N lar ® - 4G • II — _ _ — szet PROpe. :14-‘ -.. 4 1 , AC-5 iv OREGON .1 150 CFH 4'ttIE 5 ON e ..5.° ,T4. mcc,o-v 1,4.G_____ —mi.. EXPIRES: 12/31/18 0 project tine: Ding Tel rung 0 Washington Square 9677 SW Washington Square Road Tigard,OR 97223 0 0 — ,—. — 0 2*VTR CI IN data: description: AC-3 I 150 CFH ,... 3/4"0 Ark Mill iw F— GI LU CO Z f5 .3"VTR As (...9 co w 0 03 \\_. ...... , dote: 3/4"G DN INTO CEILING SPACE ...C.N ROUTE 2"GAS ALONG ROOF AND THEN DOWN EXTERIOR &MIN tit.10 PLAN-PLUMBING WALL TO NEW GAS METER LOCATION. COORDINATE LOCATION,INSTALLATION SERVICE WITH SERVING UTILITY.PROVIDE ALL VALVES,REGULATORS OTHER APPURTENANCES FOR COMPLETE OPERATION SYSTEM. N PROVIDE SEISMIC VALVE ON GAS SUPPLY LINE. A 'I ROOF PLAN - PL M N 4,388 CFH 2 PSI DELIVERY PRESSURE APPROX.395 TOTAL DEVELOPED LENGTH. Illyo 2 4' 8number SCALE:114 1'-0" P3.0 ..._____----- FILE: 0046—P30.DWG — P30 I EDIT: 4/27/2018 9:30 AM BY HUONGN I PLOT: 4/27/2018 11:38 AM BY HUONG NGUYEN \ CLR 2111 TO BUILDING ?______--_— „_ /401.1w — — FLUES SEE 53.63 HWSFU MECHANICAL Che tfl G .. y PLANS,TYPICAL 314'G BALANCING (j�y 1516 Melrose Ave.,Suite 200 VALVE `� n SET TO 9 GPM p REDUCED PRESSURE ZONE BACKFLOW Seattle,Washigton 98122 K PREVENTER WAR GAP DRAIN 2116 9381501 FROM BUILDING?--------......-3/4.--____2: - . 1! . . . NC U 2- NVDOMESTIC ( �' PE7E'5 PLUG(TYP.) 4 1V/ COLD WATER .„ r ..�... 2 �.---..�... .. SUPPLY IC w NOTE: t PQ I .fi:.4 ' ,it.n. ►4TOMAKEUPCONNECT AOUASTAT AND 1.� C9 R ird Z g' CIRCULATIONUTOMPUMPS YSTE T. BUILDING ` ROUTE TO PRESSURE REGULATING E AUTOMATION SYSTEM. OWNER TO 199 CFH NEAREST AIR GAP FITTING g PROVIDE HOURS OF OPERATION FLOOR `"�illi, VALVE;SET AT 30 PSI. FOR EACH PUMP `....�. OMR/SINK ! 1 ROUTE AIRGAP DRAIN PIPING I w Fl" v ' TO FLOOR SINK OR FLOOR DRAIN ,- `� NOTE: SEE FLOOR PLAN FOR +`Z PIPE SIZES. ' 1$og$c CONDENSATE a a 8 y 4'THICK HOUSEI NEUTRALIZATION KEEPING PAD U F 1 KIT A RECEPTOR V 1 GAS WATER HEATER — STORAGE RM 108 5 MAKE-UP WATER STATION DETAIL NO SCALE NO SCALE SUPPORT PUM- AT BOTH INLET AND DISCHARGE HANG FROM STRUCTURE WITH STEEL RODS. TEST PORT(TYP.) 0 i--.......----- I GEM I ......._—.....e FLOW PUMP 2 CIRCULATION PUMP NO SCALE CONNECT TO EQUIPMENT .t. O I GAS SHUTOFF VALVE ;1t, ;'� UNION I �'"- i REDUCER(AS REQUIRED.) ♦1i SEE FLOOR PLAN FOR EXACT SIZE. '' MINIMUM DISTANCE IS 10x PIPE DIAMETER. PRESSURE REGULATOR(WHERE REQUIRED) DRIP LEG VENT TO OUTSIDE AS REQUIRED BY CODE TEST TEE COORDINATE ROUTING. �\`' PROP fS ..f?�ryGINE'�. 46 84929 w; 4 ' /f" a 0' OREGON re i. 5 2P P$ iS4, McCIP>. EXPIRES: 12/31/18 3 GAS FIRED EQUIPMENT CONNECTION project title: NO SCALE Ding Tel Fung Washington Square 9677 SW Washington Square Road Tigard,OR 97223 INSTALL VENT RETURN BEND AS HIGH AS POSSIBLE,H —Y� NOT THAN THE FIGHT HT OF THE DRAIN BOARD. \i, -+- y FIiv XTURE WALL Z date: description: I 1 \..J I \ wco wco o I -1— ..._j wcQ IFLOOR 1 I ! III -4-- I —SLOPE2%____, 4-) ./1---FOOT./1---FOOT VENT I LU of)Y/ z 0 4 ISLAND VENT 01 NO SCALE W 0 date: drawing tftte DETAILS-PLUMBING number P5.0 FILE: 0046—P50.DWG — P50 I EDIT: 4/26/2018 3:20 PM BY TOWS I PLOT: 4/27/2018 11:38 AM BY HUONG NGUYEN