Plans (5) 1: U ID' 0 I :: - 00276 • • 01 00 00 GENERAL DATA COAT(LEVEL 3 FINISH). PAINT AS INDICATED. 2. IN NEW CEILING GRID SYSTEMS OVER 144 SF PROVIDE FLEXIBLE HEADS FOR MINIMUM SEISMIC MOVEMENT. a. AT RAISED SLABS: USE WIREMOLD RC7 FLUSH POKE-THRU SERIES OR EQUAL TENANT IMPROVEMENT nG p GENERAL REQUIREMENTS 4. IN FINISHED SPACES FURR OUT BUILDING COLUMNS AND EXTERIOR WALLS WITH 5/8"GYPSUM BOARD OVER NO"OOPS RINGS ALLOWED". b. AT SLAB ON GRADE:USE WIREMOLD RFB4E BOX WITH 6CTC2 COVER AT CONFERENCE ROOMS AND KE Ah�n METAL STUDS. 23 00 00 HVAC : DESIGN 1 BUILD 6CFFTC COVER AT FURNITURE FEEDS. PROVIDE 1"CONDUIT FOR POWER AND 2"CONDUIT FOR DATA. `1(� 1. ALL CONSTRUCTION WORK SHALL BE DONE IN COMPLIANCE WITH THE LATEST EDITION OF THE OREGON f 5. PROVIDE ACOUSTIC GASKETS WHERE WALL INTERSECTS STOREFRONT.QUIETJOINT SHH WHERE WALL STRUCTURAL SPECIALTY CODE AND ALL OTHER STATE OR LOCAL CODE REQUIREMENTS THAT APPLY. GAS METER 12.LOW VOLTAGE SYSTEMS(TELECOMMUNICATION AND DATA)BY FUTURE TENANT. for r .-A 2. MEETS MULLION AND QUIETJOINT SHG WHERE WALL MEETS GLAZING.COLOR SELECTED BY ARCHITECT. '• MICHAEL 2. VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON DRAWINGS AND AT THE EXISTING BUILDING AND 1. CONTRACTOR TO VERIFY GAS METER AND TAG METER WITH THE TENANTS ADDRESS OR SUITE NUMBER. 13.LIGHTING ENERGY MANAGEMENT IS REQUIRED IN ALL BUILDINGS. CD WIRE THWANG cfl 6. AT ALL EXISTING WALLS,REMOVE ALL NAILS,SCREWS,FASTENERS,ETC.LEFT BY PREVIOUS TENANT AND i1 NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING THE WORK. PATCH HOLES READY FOR PAINT. METER IDENTIFICATION NUMBER AND TENANT ADDRESS INFORMATION SHALL BE GIVEN TO PACTRUST PRIOR 14.LIGHTING ENERGY MANAGEMENT IS REQUIRED IN BUILDING AREAS 5,000 SF AND LARGER. C LLl �) 3. CONTRACTOR AND ALL SUBCONTRACTORS SHALL PERFORM DUE DILIGENCE INSPECTION OF ALL EXISTING TO TENANT'S MOVE-IN. 15.00CUPANCY CONTROL DEVICES SHALL BE LEVITON OR WATT STOP. -I CONDITIONS PRIOR TO OF A PROPOSAL.SUBMITTAL OF A PROPOSAL SHALL BE CONSIDERED 7. REPAIR GYPSUM BOARD AT REMOVED ELECTRICAL RECEPTACLES OR DATA BOXES AND FINISH READY FOR HVAC-BID PROCEDURE • CONFIRMATION THAT SUCH SUBMITTAL F A HAS BEEN MADE,AND NO FURTHER COMPENSATION SHALL BE DUE PAINT 16,TEST ALL LIGHTING CONTROL SYSTEMS TO ENSURE THAT CONTROL DEVICES,COMPONENTS,EQUIPMENT QC F r 1. FOR BIDDING PURPOSES,THE HVAC CONTRACTOR WILL ASSUME THAT EXISTING HVAC EQUIPMENT IS IN PACTRUST '� 2018 J).A PORTLAND,OREGON THE CONTRACTOR FOR CLAIMS ARISING AS A RESULT OF FAILURE TO PERFORM SUCH INSPECTION. 8. UPON REMOVAL OF WALL BASE,REMOVE RESIDUAL ADHESIVE AND PREP WALL TO PAINT READY CONDITION. AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND 4. BY SUBMITTING A PROPOSAL,CONTRACTOR AND ALL SUBCONTRACTORS CERTIFY THAT THEY HAVE WALL CONSTRUCTION MATERIALS PROPER WORKING ORDER. SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE (;jTY Q (�`��� 1� 5851 2COMPLETE THE WORK . INVENTORY EXISTING H.V.A.C.ROOFTOP UNITS AND SUBMIT TO ARCHITECT A CONDITIONS REPORT OF EACH IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. �C DESCRIBEXAMINEED OR RTHE ITE AND INCLUDED EASONABLY IMPLIEDN THEIR PROPOSAL ALL IN THESE dOCUMENTSWTHIS RK NNCLUDES BUTSSARY MAY NOT BE LIMITED TO 1. PROVIDE STUDS,TRACKS, BRACING,FASTENING AND OTHER ACCESSORIES NECESSARY FOR COMPLETE UNIT 17.REMOVE ALL UNUSED DATA AND POWER BOXES AND INFILL WITH GYP BOARD. EXCEPTION-UNUSED DATA tJ! Q{�O hl'lfj�')o ` O� ALL MATERIALS AND INSTALLATION,DISPOSAL OF EXCESS MATERIALS(USEABLE FINISH MATERIALS SHALL BE INSTALLATION. 3. LIST TONNAGE OF EACH UNIT. BOXES UNDER WINDOW SILLS TO REMAIN. ALL BLANK COVER PLATES TO BE BUILDING STANDARD FINISH. OF LEFT IN THE TENANT SPACE AS NOTED ON PLANS),CLEANING AND ALL PREPARATION OF SUBSTRATE 2. FRAMING MEMBERS SHALL HAVE THE STRUCTURAL PROPERTIES INDICATED WHERE PHYSICAL STRUCTURALHVAC-DESIGN PROCEDURE18.REMOVE ALL UNUSED LOW VOLTAGE WIRING(TELEPHONE AND DATA)FROM THE RECEPTACLE TO THE TEN ANT. SURFACES PRIOR TO INSTALLATION,AS WELL AS FINAL CLEAN UP. PROPERTIES ARE NOT INDICATED,THEY SHALL BE AS NECESSARY TO WITHSTAND ALL IMPOSED LIVE LOADS. DISTRIBUTION BOARD.LEAVE PULL STRINGS FROM THE BOX TO THE SPACE ABOVE THE CEILING. A SECTION • 5. ITIS THE INTENT OF THESE CONTRACT DOCUMENTS TO MATCH AND MAINTAIN EXISTING BUILDING DESIGN FRAMING IN ACCORDANCE WITH NS!SG 673. 1. USE EXISTING AND/OR NEW EQUIPMENT TO DESIGN MECHANICAL H.V.A.C.SYSTEM PER DESIGN STANDARDS OF THE EXISITNG LOW VOLTAGE WIRE MAY BE LEFT IN LIEU OF A PULL STRING THE F I L K 1 N S GROUP (33000 PROJECT # STANDARDS FOR ALL EXISTING PRODUCTS AND SYSTEMS. UPON DISCOVERY OF A DISCREPANCY TO THIS 3. COLD FORMED FRAMING SHALL BE GALVANIZED METAL CONFORMING TO ASTM A4461A 446 M GRADE ALISTED BELOW. OFFICE LIGHTING INTENTION,THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY. PSI)G60. 2. PRIOR TO AWARD OF CONSTRUCTION CONTRACT,H.V.A.C.CONTRACTOR SHALL SUBMIT TO ARCHITECT FOR REVIEW AND APPROVAL A FULL DESIGN SCHEMATIC FOR THE TENANT SPACE INCLUDING BOTH 1. REUSE EXISTING FIXTURES-OFFICE LIGHT FIXTURES: LITHONIA LED FIXTURE.2BLT2 40L ADP MVOLT EZ1 I! 6. FURNISH ALL NEW MATERIALS EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE. 4. PROVIDE THE LISTED GYPSUM BOARD PRODUCTS BY U.S.GYPSUM,GEORGIA PACIFIC,NATIONAL GYPSUM OR NEWIRENOVATED WORK AND SYSTEMS UNTOUCHED BY THE TENANT IMPROVEMENT AS APPLICABLE. LP835. 2909 S W 68TH PARKWAY, SUITE #250 7. COORDINATE THE WORK OF ALL TRADES. PROVIDE CARPET"WALK-OFF MATS"TO PROTECT EXISTING AN APPROVED EQUAL. INCLUDE THE FOLLOWING: PORTLAND, OR 97223 • CARPETS. 5. STANDARD GYPSUM BOARD SHALL BE TYPE'X',518"THICK WITH TAPERED EDGES CONFORMING TO ASTM 2. OFFICE EGRESS LIGHTING:ISOLITE MINI GENIE SERIES LED VERSION LMIGN NM SQ CEILING AND WALL • • a. DUCTING AND SIZES MOUNT. SEE PLAN FOR EGRESS PATH.USE OF!SOLITE INVERTER AS ALTERNATE TO BATTERY IS 8. ALL ROOF PENETRATIONS FROM ABANDONED EQUIPMENT TO BE REMOVED. PATCH AND REPAIR ROOF AND C-36. ACCEPTABLE. ROOF MEMBRANE TO MATCH THE EXISTING ROOF. 6. WATER RESISTANT GYPSUM BOARD SHALL BE 5/8"THICK WITH TAPERED EDGES. CONFORMING TO ASTM b. SUPPLY AND RETURN LOCATIONS AND CFM AT EACH GRILL OR DIFUSER 3. LIGHT SWITCHES:ACUITY CONTROLS PRE SET ALL PRIVATE OFFICE AND CONFERENCE ROOM SWITCHES TO C-630. c. ROOF EQUIPMENT,SIZES AND LOCATIONS "VACANCY"AND TO TURN ON AT LAST DIM LEVEL. PROJECT NARRATIVE 9. ALL ROOF WORK TO BE PERFORMED BY PACTRUST APPROVED ROOFING COMPANIES. APPROVED COMPANIES INCLUDE: 7. AT TOILET ROOMS USE 5/8"USG FIBERROCK BRAND AQUATOUGH INTERIOR PANEL FROM FLOOR TO 48"A.F.F. d. UNITS REQUIRING DUCTED SMOKE DETECTION a. STANDARD WALL SWITCH WITH OCCUPANCY SENSOR-USE WSD a. ON WALLS BEHIND OR ADJACENT TO PLUMBING FIXTURES. NO SUBSTITUTES.(EXCEPTION:EXCEPTION AT ARROW ROOFING, 503 460-2767 e. THERMOSTAT LOCATIONS AND ZONE/UNIT ASSOCIATED THEREWITH LOCATIONS TO RECIEVE PLASTIC LAMINATE OR TILE WAINSCOT.) b. WALL SWITCH WITH OCCUPANCY SENSOR AND DIMMING-USE WSXD PROJECT CONSISTS OF TENANT IMPROVEMENT WORK WITHIN 2,878 RENTABLE SF OF Q b. PACIFIC ROOFING,503-640-3163f. ANY SUPPLEMENTAL EXHAUST FANS OR SPECIAL SYSTEMS WALL SWITCH WITH DIMMING ANO CEILING MOUNTED OCCUPANCY SENSOR-USE SPOD EXISTING OFFICE SPACE. WORK SHALL INCLUDE BUT NOT BE LIMITED TO SELECTIVE - 8. AT TILE WAINSCOT LOCATIONS INSTALL CEMENT BACKER BOARD A�"THICK WITH SQUARE,REINFORCED, c. „ c. ROOF TOPPERS,360-574-7248 SMOOTH EDGES. PROVIDE DUROCK BRAND CEMENT BOARD OR APPROVED EQUAL. g. ZONE DIAGRAM 28 30 00 ELECTRONIC DETECTION AND ALARM DEMOLITION, DRYWALL/METAL STUDS, SUSPENDED CEILINGS, DOORS/FRAMES, FINISH C d. GOT YOU COVERED ROOFING,503-975-9136 9. INSTALL WATER-RESISTANT GYPSUM BOARD BEHIND WAINSCOT OF FRP,PLASTIC LAMINATE,ETC. HVAC DESIGN STANDARDS GENERAL WORK AND PAINTING. ALL WORK TO MEET ADA REQUIREMENTS. CO . - (VERIFY WITH SHELL CONSTRUCTION ANY WARRANTY REQUIREMENTS) 10.TRIM ACCESSORIES SHALL COMPLY WITH ASTM C-1047. THE FOLLOWING ARE MINIMUM DESIGN STANDARDS: FOR HORN/STROBE DEVICES USE"SYSTEM SENSOR"SPECTRALERT ADVANCE DEVICES,OR APPROVED EQUAL. 10.KEEP THE AREA OF WORK FREE OF GARBAGE AND DEBRIS ON A DAILY BASIS INCLUDING DOCK ACCESS 11.USE GEORGIA PACIFIC DENSGLAS GOLD ON EXTERIOR FACE OF EXTERIOR WALLS AND COAT WITH STO FINISH 1. 350 SQUARE FOOT PER TON(UNLESS OTHERWISE APPROVED IN WRITING BY PACTRUST). WORK INCLUDED BUT PERFORMED UNDER SEP. PERMIT -C O AREAS AND COMMON AREA. FLOORS TO BE SWEPT OR VACUUMED DAILY. SYSTEM. I . O 2. ADDRESS LOADS BY SPECIFIC LOCATION AND USE,AS WELL AS CRITERIA PROVIDED TO PACTRUST BY 11.PROVIDE ADEQUATE PROTECTION TO ALL EXISTING IMPROVEMENTS INCLUDING BUT NOT LIMITED TO WALL CONSTRUCTION EXECUTION TENANT PRIOR TO CONSTRUCTION: PLUMBING WORK COMMON CORRIDORS AND STAIRS,BUILDING ENTRANCES,SUITE ENTRANCES, ETC. THE CONTRACTOR WILL �-- BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGES TO EXISTING IMPROVEMENTS DUE TO CONSTRUCTION 1. FASTEN FRAMING MEMBERS TOGETHER BY WELDING OR BY USING SELF-DR1LLING OR SELF-TAPPING a. EXTERIOR EXPOSURE AREAS FIRE PROTECTION SPRINKLERING SCREWS. WELDING SHALL CONFORM TO AWS D13 WELDING PROCEDURE. ELECTRODES AND SCREW HEATING, VENTILATION &AIR CONDITIONING WORK c0 ACTIVITIES. b. INTERIOR AREAS,SIZE AND USE C CONNECTIONS SHALL BE AS REQUIRED AND INDICATED IN THE DESIGN CALCULATIONS. DO NOT FIELD WELD ELECTRICAL WORK-LINE VOLTAGE Y Ov 12.PROVIDE TEMPORARY SANITARY FACILITIES. CONSTRUCTION WORKERS SHALL NOT USE BUILDING MATERIALS LIGHTER THAN 18 GA. c. CONFERENCE/TRAINING ROOMS C`3 0.. O. RESTROOM FACILITIES. ELECTRICAL WORK- LOW VOLTAGE (EXTENSION/MODIFICATION OF FIRE ALARM SYSTEM) < N a 2. PROVIDE ACCURATELY ALIGNED RUNNERS AT TOP AND BOTTOM OF PARTITIONS. ANCHOR TRACKS AS d. COMPUTER/SERVER AND TELEPHONE ROOMS TO HAVE PROVISION FOR LOW AMBIENT OPERATION 13.STORAGE AND STAGING OF CONSTRUCTION MATERIALS SHALL BE LIMITED TO AREAS AS DESIGNATED AT INDICATED IN THE DESIGN CALCULATIONS. BUTT WELD JOINTS IN TRACKS OR SPLICE WITH STUD INSERTS. AND 24-HOUR USE.VERIFY NEED FOR A SEPARATE SPLIT SYSTEM TO MAINTAIN TEMPERATURE. N- W PRE-CONSTRUCTION MEETING. UNDER NO CIRCUMSTANCES SHALL BUILDING UTILITY AREAS OR ANY OTHER FASTENERS SHALL BE AT LEAST 3 INCHES FROM THE EDGE OF CONCRETE SLABS. 3. SYSTEM DESIGN CRITERIA-SIZE ZONES FOR 3-5 TON UNITS BASED ON USE&EXPOSURE CRITERIA. DRAWING INDEX � O O H COMMON BUILDING AREA BE USED FOR STORAGE. 3. CUT STUDS SQUARE AND SET WITH FIRM BEARING AGAINST WEBS OF TOP AND BOTTOM TRACKS. POSITION PACKAGED OR SPLIT SYSTEM EQUIPMENT GREATER THAN 5 TONS SHALL BE SPLIT INTO MULTIPLE ZONES. A-1 GENERAL INFORMATION, FINISHES, NOTES & LEGEND 0 '- 14.KEEP THE ROOF FREE OF DEBRIS(I.E.NAILS,SCREWS.BOTTLES,ETC.)AT ALL TIMES. STUDS VERTICALLY IN TRACKS AND SPACE AS INDICATED IN DESIGN. DO NOT SPLICE STUDS. PROVIDE AT VAV OR WATER SOURCE HEAT PUMP SYSTEMS GREATER THAN 3 TONS SHALL BE SPLIT INTO MULTIPLE A-2 PARTITION PLAN W/DEMOLITION d O 1.7 LEAST O FULL HEIGHT KING STUDS AT LARGER. 15.ALL DIMENSIONS ARE TO FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. JACK STUDS OVER OPENINGS,AS NECESSARY, O MAINANDOTAIN INDICATED STUD OPENINGS 2 FETHER SPACING WIDER PROVIDERRIPLEIdE ZONES. A-3 REFLECTED CEILING PLAN W/DEMOLITION - 0') ❑ F. ti CO 16.CONFIRM SIZES OF ALL OPENINGS REQUIRED FOR THE INSTALLATION OF STRUCTURAL,MECHANICAL, STUDS AT CORNERS, POSITIONED TO RECEIVE INTERIOR AND EXTERIOR FINISHES. FASTEN STUDS AT TOP 4. ALL ENCLOSED ROOMS OR OFFICES TO HAVE DUCTED SUPPLY&RETURN GRILLES. A-4 DETAILS I) Z , 4 U' ELECTRICAL AND PLUMBING WORK PRIOR TO FRAMING OR CUTTING FOR INSTALLATION. AND BOTTOM TRACKS BY WELDING OR SCREWING BOTH FLANGES TO THE TRACKS.PROVIDE LONG LEG 5. VACANT SPACE SHALL HAVE DEDICATED GAS SERVICE FOR FUTURE BUILD-OUT OR FREEZE PROTECTION. CO 03 Q ( I (NI Z TRACK AT TOP OF WALL TO ALLOW FOR DEFLECTION WHERE WALL MEETS STRUCTURE ABOVE. 17.LEAVE THE PROJECT CLEAN AND READY FOR OCCUPANCY. 4. INSTALL ALL INTERIOR AND EXTERIOR GYPSUM BOARD PRODUCTS AND ACCESSORIES AS REQUIRED FOR 6 TONS SHALL UNITS: pHAVE SPECIAL WRITTEN APRK OR IPROVAL FROM PACER-7 1/2-TON ITRUSTMUM NIT SIZE. ANY UNIT IN EXCESS OF 7 1/2 BUILDING INFORMATION TENANT INFORMATION 0 On 11 M M 18.CLEAN ADJACENT EXTERIOR AREA,I.E.WALKS,EXTERIOR GLASS,ETC. THE PROJECT. OWNER: PACIFIC REALTY ASSOCIATES, L.P. TENANT: -C O O 19.FILL ALL PAPER AND SOAP DISPENSERS IN RESTROOMS AND BREAK AREAS. 7. HVAC UNITS EQUAL TO OR GREATER THAN 5-TONS TO HAVE DUCT SMOKE DETECTORS AND BE CONNECTED t17 D • 5. AT TOILET ROOMS TO RECEIVE SHEET VINYL FLOORING,INSTALL THE GYPSUM BOARD(OR AUQATOUGH) TO A MONITORING STATION WITHIN THE BUILDING, 15350 SW SEQUOIA PKWY#300' SPEC WORK C D- m 20.CLEAN ALL SUPPLY AND RETURN DIFFUSERS AT PROJECT COMPLETION. WITH 1/4"GAP BETWEEN THE BOARD AND THE FLOOR TO PREVENT WICKING. 8. ROOF TOP UNITS SHALL BE PLACED 24'MINIMUM FROM ROOF EDGE TO CENTER OF UNIT. MULTIPLE UNITS PORTLAND,ORE 97224 • 21.PROVIDE"AS-BUILT"DRAWINGS OF THE WORK AT THE CONCLUSION OF CONSTRUCTION."AS-BUILT" fi. COMPLY WITH USG GYPSUM CONSTRUCTION HANDBOOK AND MANUFACTURER'S RECOMMENDATIONS. SHALL BE PLACED SYMMETRICALLY IN A LINE BASED ON LOAD CALCULATIONS BY STRUCTURAL ENGINEER. OCCUPANCY AREAS&LOADS: DRAWINGS MAY BE IN THE FORM OF TWO COPIES OF CONSTRUCTION DOCUMENTS MARKED-UP WITH RED 7. FINISH QUALITY: 9. CURBS: 14"HIGH CURBS. ASSEMBLED AND LEVELED TO ROOF,ANCHORED TO STRUCTURAL MEMBERS (503)624-6300 (PHONE) USABLE 2,604 SF 26 OCC PEN. DELIVER RECORD DRAWINGS TO THE ARCHITECT. COMPLETE OPERATION AND MAINTENANCE MANUALS BELOW ROOFING. SHALL BE PROVIDED FOR ALL MECHANICAL, ELECTRICAL AND PLUMBING EQUIPMENT.PROVIDE AS-BUILT CAD AREA PROCESS TRADE NOMENCLATURE (503)624-7755(FAX) RENTABLE 2,878 SF FILES TO PACTRUST FOR ALL MEP TRADES.PACTRUST MAY HOLD CONTRACTOR'S FINAL PAYMENT UNTILWAREHOUSE TAPE/FINISH COAT` TIGHT DOUBLE(LEVEL 3) a. PROFESSIONALLY ROOF IN ALL CURBS AND PENETRATIONS BY PACTRUST APPROVED ROOF "AS-BUILT"DRAWINGS AND 0&M MANUALS HAVE BEEN RECEIVED AND APPROVED. CONTRACTOR. SEE DIVISION 1 GENERAL NOTES THIS PAGE. BLDG. #: BLDG. B 0082 NUMBER OF EXITS REQUIRED OFFICE/OTHER AREAS TAPE/2 FINISH COATS`/ SMOOTH FINISH TAPED(LEVEL 4) (ppc082) 22.IT IS THE INTENT OF THE CONTRACT DOCUMENTS THAT THE CONTRACTOR PROVIDE A COMPLETE, b. UNIT MUST BE LEVEL,SEALED WITH NO AIR LEAKS AND COUNTER FLASHED. B 1 EXIT FUNCTIONING PROJECT INCLUDING ALL GENERAL,MECHANICAL AND ELECTRICAL CONSTRUCTION REQUIRED USG"FIRST COAT' *SAND AFTER TAPE/FINISH COAT(5) c. CONDENSATE MUST BE TRAPPED AT UNIT. TO FULFILL THAT INTENT. ALL ITEMS REQUIRED SHALL BE FURNISHED AND INSTALLED,REGARDLESS OF NOTE:AT EXTREMELY DARK ACCENT WALLS PROVIDE LEVEL 5 FINISH. CONST.TYPE.: II-B 1 PROVIDED WHETHER OR NOT SHOWN ON THE DRAWINGS. 10.SEISMICALLY ATTACH UNIT TO CURB IN CODE-APPROVED METHOD. 23.1TEMS OR WORK NOT TO BE FURNISHED OR ACCOMPLISHED BY CONTRACTOR ARE NOTED"N.I.C,". 8. FINISH EXPOSED INTERIOR GYPSUM BOARD WALLS AND CEILINGS SMOOTH STRAIGHT READY FOR FINISH AS 11.ALL GAS PIPING SHALL BE STANDARD BLACK STEEL PIPE WI SUPPORTS PER CODE. PIPING SHALL BE RUN THIS BUILDING HOUSES MULTIPLE TENANTS INCLUDING THIS TENANT. THE EXISTING 24."ALIGN"AS USED IN THESE DOCUMENTS,MEANS TO ALIGN THE FINISHED FACES OF ELEMENTS IN THE SAME SHOWN ON PLANS. INSIDE OF BUILDING W/LEAD FLASHINGS AT ROOF PENETRATIONS. LEAD ROOF JACKS TO BE SEALED AND BUILDING IS A FOUR STORY BUILDING OF 87,890 SF AND IS FULLY SPRINKLERED. EACH PLANE,EITHER IMMEDIATELY ADJACENT TO ONE ANOTHER OR ACROSS AN OPENING. 09 53 00 SUSPENDED ACOUSTICAL CEILINGFLOOR IS LESS THAN 23,000 SF ALLOWING FOR NON SEPARATED USE. 25.00 NOT DISASSEMBLE SETS OF CONSTRUCTION DRAWINGS.DRAWINGS ARE INTERRELATED. 12.ALL EXISTING AND NEW GAS PIPING EXPOSED TO THE EXTERIOR TO BE PROTECTED FROM RUST AND • 1. COMPLY WITH CURRENT SEISMIC REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE, CORROSION WITH OIL BASED PAINT(COLOR GREY). . 26.SUBMIT SAMPLES OR DRAW DOWNS FOR ALL FINISHES REQUESTED TO THE ARCHITECT OF RECORD WITHIN 2, FOLLOW MANUFACTURERS PRINTED INSTRUCTIONS FOR THE DELIVERY AND INSTALLATION OF CEILING 13.LOW VOLTAGE IN SEALTITE CONDUIT FROM BELOW ROOF LINE DIRECT TO UNIT. DO NOT EXCEED BEND TWO WEEKS OF PROJECT AWARD.PRODUCTS INSTALLED WITHOUT APPROVED SAMPLES ARE SUBJECT TO SYSTEM, INCLUDING GRID,PANELS,AND HANGARS AND ACCESSORIES. RADIUS OF MANUFACTURER'S GUIDELINE. REPLACEMENT AT CONTRACTOR COST.AN APPROVED SUBMITTAL DOES NOT CHANGE THE CONTRACTUAL PROJECT LOCATION I , REQUIREMENT TO PROVIDE THE SPECIFIED ITEMS UNLESS SPECIFICALLY NOTED AS A SUBSTITUTION BY THE 3. USE ALL PRODUCTS FROM ARMSTRONG WORLD INDUSTRIES, INC. 14.ECONOMIZER TO MEET CODE AND AS FOLLOWS: J S•W. HAMPTON STREET CONTRACTOR AND SPECIFICALLY APPROVED BY THE ARCHITECT AS SUCH.REPLACE SUCH PRODUCTS AS 4. CO-ORDINATE CEILING WORK WITH INSTALLERS OF RELATED WORK INCLUDING BUT NOT LIMITED TO a. 6 TONS AND ABOVE MUST HAVE ECONOMIZER. _ i) �-- - DIRECTED AT CONTRACTOR'S COST. INSULATION, GYPSUM BOARD, LIGHT FIXTURES,MECHANICAL SYSTEMS, ELECTRICAL SYSTEMS AND FIREJ -- -- - �� SPRINKLERS b. BAROMETRIC RELIEF ON 5 7 1/2 TON UNITS. 27.SUBMIT COMPLETE SHOP DRAWINGS FOR MILLWORK,SPECIAL SYSTEMS, MECHANICAL, ELECTRICAL AND -�� --- PLUMBING SYSTEMS(INCLUDING FIRE PROTECTION SYSTEMS). SUBMIT A MINIMUM OF TWO COPIES OF ALL c. 8 TONS AND ABOVE MUST HAVE POWER EXHAUST. �*•111 � _ SHOP DRAWINGS FOR REVIEW AND APPROVAL TO THE ARCHITECT OF RECORD.ARCHITECT WILL RETAIN ONE 5. PRODUCTS: >. I COPY AND ONE COPY WILL BE RETURNED TO THE CONTRACTOR. a. EXISTING GRID AND TILES TO REMAIN.IF DAMAGE OCCURS,USE THE PRODUCTS BELOW. d. 1 1/2 THRU 4-TON OSA INTAKE WITH DAMPER. �, 1Q+! • i I W1, 1 I I ! 15.ALL UNITS TO MEET OR EXCEED CURRENT ENERGY EFFICIENCY CODE REQUIREMENTS. I it I Q } 28.THE DESIGN OF FIRE PROTECTION SYSTEMS IS THE RESPONSIBILITY OF THE FIRE PROTECTION SYSTEMS b. GRID-PRELUDE 24 XL 15/16"EXPOSED TEE(HEAVY DUTY) P }ti -f- r y k', III ■•;•• ••rte• I I 1 I I -� CONTRACTOR.ALL FIRE PROTECTION SYSTEMS SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER 16.DROP CANS TO BE SAME SIZE AS CURB OPENING AND TO EXTENDED TO WITHIN 2'OF SUSPENDED CEIILING. g " L LICENSED BY THE APPROPRIATE JURISDICTION FOR THE DESIGN OF THIS TYPE OF SYSTEM. COORDINATE c. TILES-ARMSTRONG FINE FISSURED#1732,24 x 24 x 5/8"W/ANGLED TEGULAR EDGE MINIMUM 26 GAUGE FOR SUPPLY AIR. SEAL EDGES OF SUPPLY AIR. . ,1 /Q!' - -�__ Ft- j - IM INTERFACE WITH EXISTING BUILDING SYSTEMS AND WITH ARCHITECT. ALL SPRINKLER HEADS SHALL BE d. ACCESSORIES-MANUFACTURERS'STANDARD 17.DISTRIBUTION DUCTWORK: /' -�= J 11 CENTERED IN CEILING TILE{OR 2 x 2 MODULE OF A SECOND LOOK II TYPE OF CEILING TILE WHERE 6. ALL TILE CUTS SHALL BE DONE WITH RAZOR SHARP KNIVES. CUT/TRIM TILE EDGE TO CREATE TEGULAR EDGE - �_- - l APPLICABLE). LOCATION OF THOSE IN GYPSUM BOARD CEILINGS SHALL BE PRE APPROVED IN WRITING BYa. SPIRAL DUCT PERMITTED ONLY IF EXPOSED. jl Hrl °DiI _ _{ -r • \ •THE ARCHITECT PRIOR TO INSTALLATION. CONDITION SO THAT CEILING TILES LAY FLAT. 1 fW (I)b. 26 GAUGE OR TO SMACNA STANDARDS WHERE DUCT IS CONCEALED ABOVE A CEILING. r29.COORDINATE ALL CONSTRUCTION SEQUENCING WITH PACTRUST AND SCHEDULE ALL SERVICE 7. IN EXISTING SPACES REPLACE WATER STAINED OR DAMAGED TILES. I� II - lCt:i 1 INTERRUPTIONS OUTSIDE NORMAL BUSINESS HOURS TO MINIMIZE INCONVENIENCE TO CURRENT TENANTS. T NE P SYSTEM TO WITHIN PLUS M[NU5 c. WRAP CONCEALED SUPPLY DUCTWORK IN NON-CONDITIONED AND SEMI-CONDITIONED SPACE WITH I I J - \.,,,I3 8 U U GRIDOR0.5 INCHES OF LEVEL. MINIMUM R4.2 INSULATION WITH FSK BARRIER. I I ; GENERAL 9. BENT OR DAMAGED T-BARS TO BE REPLACED. ,� I d. HANGERS 12 GAUGE WIRE OR 18-GAUGE 1"WIDE STRAP. EXPOSED DUCT MUST HAVE ALL THREAD i Y Mme' ' ''y '•^J 1. REMOVE ALL EXISTING VCT,SHEET VINYL,ETC.IN AREAS WHERE NEW FLOOR COVERING IS SPECIFIED PRIOR 10.REPAIR HOLES IN GRID FROM REMOVED WALLS. USE OF ARMSTRONG"BP ES-4"EXPANSION SLEEVE HANGERS AND FULL DIAMETER STRAP UP TO 18"0. LARGER THAN 18"MUST HAVE SADDLE TYPE CLAMP. • )) _ f A _ y ➢', TO INSTALLATION OF NEW FLOORING. ACCEPTABLE. �--�. II, �-� I 1 ; ; e. BRANCH DUCTS SHALL BE PLUMB AND SQUARE(NO OCTOPUS). TEES SHALL BE MAXIMUM OF 45 ! I E I III , F' 2. ALL ROOF PENETRATIONS FOR ELECTRICAL,LOW VOLTAGE.GAS PIPING,ETC.SHALL BE SLEEVED THROUGH 09 62 00 SPECIALTY FLOORING DEGREES. A LEAD ROOF JACK,CLAMPED WITH A STAINLESS STEEL CLAMP AND SEALED WITH VULKEM 921 i {� .1.--.11"---n ' I I I I L{! I I I I I } 71 POLYURETHANE SEALANT. SILICONE SEALANT NOT PERMITTED. f. EACH BRANCH DUCT TO HAVE BALANCE DAMPER IN Y BRANCH. �: 09 65 19 RESILIENT FLOORING -LUXURY VINYL TILE g. ALL DISTRIBUTION DUCT WORK TO BE INSTALLED MIN.24"ABOVE FINISH CEILING. 11 1 ! I :�� I • I 0 II 01 73 29 CUTTING AND PATCHING 18.FLEX DUCT WILL BE NO LONGER THAN 6'FROM RIGID DUCT DOWN TO DIFFUSER. f - I 1' I ' , I� Li 1. FINISH FLOORING TO EXTEND UNDER CASEWORK. I 14 1. PERFORM CUTTING AND PATCHING WITH SKILLED CRAFTSMEN EXPERIENCED WITH THE TYPE OF WORK - BEING UNDERTAKEN. 2. INSTALL PLANKS IN RANDOM ASHLER PATTERN. 19.DIFFUSERS: __ - II ' l ' } rI i' i f I 2. PROTECT EXISTING CONSTRUCTION TO PREVENT DAMAGE. 09 91 23 PAINTING a. SUSPENDED CEILING SYSTEM(T-BAR)-PERFORATED FACE ADJUSTABLE CURVED BLADES-DESIGN . I J L i 1 1 I I I I + ITITLI TITUS PCS SUPPLY AND TITUS PAR RETURN OR APPROVED EQUAL. ji ii. i III I - - -- --- ,_. -3. PERFORM CUTTING USING METHODS LEAST LIKELY TO DAMAGE ELEMENTS TO BE RETAINED. INTERIOR: b. GYPSUM BOARD CEILING;SUPPLY CURVED BLADE W/OBD DESIGN TITUS 250;RETURN-BAR TYPE- - IIL_ �_ r-. I I i lit 4. PATCH,USING MATERIALS IDENTICAL TO EXISTING MATERIALS THAT VISUALLY MATCH EXISTING ADJACENT 1. WALLS: DESIGN TITUS 350;EXHAUST-METAL OR ALUMINUM-1/2"x 1/2"EGG CRATE DESIGN TITUS 50F. 1 II- - I "� D• O SURFACES TO THE FULLEST EXTENT POSSIBLE a. PRIME NEW DRYWALL WITH MILLER'S HIGH-BUILD"SUPER SEAL"PRIMER. c. ALL SUPPLY REGISTERS TO HAVE MANUAL VOLUME DAMPERS LOCATED IN DUCT AT OR NEAR CLOSEST O L0 5. PATCH WITH DURABLE,INVISIBLE SEAMS THAT ELIMINATE EVIDENCE OF PATCHING AND REFINISHING. WYE BRANCH. i , b. NEW AND EXISTING DRYWALL TO BE FINISHED TO ACHIEVE UNIFORM COVERAGE WITH MILLER'S N 6. AT CONCRETE SLAB REPAIRS(POUR BACKS),PROVIDE#3 x 12"LONG REBAR DOWELS AT 24"O.C. MIN.WITH 120-4-XX WITH A TIGHT ROLLER STIPPLE FINISH. RESTROOM FINISHES TO BE MILLER'S 170-5-XX SIG d. CLEAN OR REPLACE ALL SUPPLY AND RETURN AIR GRILLS AND THDR HOUSINGS AT PROJECT LOCATION MAP 0 w MIN.6"PENETRATION INTO EXISTING CONCRETE AND MIN.OF 6"EXPOSURE INTO POUR BACK.CENTER LATEX ENAMEL. COMPLETION. �. DOWEL IN SLAB DEPTH. 2. GENERAL NOTES: CD 20.THERMOSTAT: ALL EXISTING MERCURY TYPE THERMOSTATS TO BE REPLACED. NEW THERMOSTATS TO BE ❑ 7. REMOVE PATCHES THAT ARE VISUALLY UNSATISFACTORY IN THE ARCHITECT'S OPINION AND REPLACE AT NO a. KEEP ALL HARDWARE,HINGES,AND DOOR KNOBS CLEAN OF ALL PAINT SPLATTERS, DRIPS,OR ROLLER HONEYWELL COMMERCIAL GRADE VISIONPRO 8000 TOUCH SCREEN MODEL TB8220U1003 WHERE POSSIBLE. A-� NOT TO SCALE - V} ADDITIONAL COST. SPRAY. APPROVED SUBSTITUTE: TOTAL-LINE SIGNATURE COMMERCIAL THERMOSTAT MODEL NO.P374-2800 -7 DAY 08 10 00 DOORS AND WINDOWS PROGRAMMABLE WITH LOCKOUT FUNCTION-AUTO CHANGEOVER ONLY. MOUNT AT ADA HEIGHT(MAY ( ') z a b. ALL SURFACES TO BE SANDED BETWEEN COATS, PRIOR TO INSTALLATION OF NEXT COAT. REQUIRE CHANGING HEIGHT AT"REPLACEMENT"LOCATIONS). CONTRACTOR SHALL PROGRAM ::AREA OF WORK ; , 9 V J 1. RE-USE EXISTING DOORS AND FRAMES WHERE POSSIBLE c. DURING PROGRESS OF WORK,KEEP JOB SITE CLEAN OF ALL PAINT MATERIALS,RUBBISH,CANS,AND THERMOSTATS AND BALANCE SYSTEM. f W 2. APPROVED DOOR,FRAME,AND HARDWARE SUPPLIERS INCLUDE: RAGS AT THE END OF EACH DAY. 21.THERMOSTAT LOCATIONS TO BE REVIEWED BY ARCHITECT PRIOR TO INSTALLATION. r..-.__, - -- - , L V ... a. BAXTER AND FLAMING. (503)225-0486 d. UPON COMPLETION OF WORK, CLEAN ANY PAINT SPLATTER BY USING PROPER METHODS OF WASHING 22.EXHAUST FANS: `` - .�� ' AND SCRAPING,USING CARE NOT TO SCRATCH OR DAMAGE FINISHED SURFACES. -- * �� ! ¢ Q CV b. D&D DOOR (503)205-5533 a. CEILING MOUNTED EXHAUST FANS SHALL HAVE A MINIMUM PERFORMANCE TO MEET THE CURRENT ;����� 5. 0- ('V c. BENSON INDUSTRIESe. PROTECT WORK OF OTHER TRADES. CODE REQUIREMENTS INCLUDING INTEGRAL BACKDRAFT DAMPER AND VENTING TO THE EXTERIOR. ti (503)907-2200 j ' Y m f. PROVIDE"WET PAINT"SIGNS AS REQUIRED TO PROTECT NEWLY PAINTED FINISHES. COOK GEMINI SERIES 100 OR EQUAL;80 CFM WITH A SONE RATING OF 1.6 OR LESS, 100 CFM WITH A w 00 d. GRANT SUPPLY (360)887-0647 SONE RATING OF.9 OR LESS,200 CFM WITH A SONE RATING OF 1.6 OR LESS. - Itia_jrn Q Et 3. DOOR AND RECITE FRAMES SHALL BE ALPHA ALUMINUM PRODUCTS, INC.(AAP)OR APPROVED, SUBMITTAL 10 00 00 SPECIALTIES b. SPECIALTY ROOMS REQUIRING EXHAUST SHALL MEET THE ABOVE MINIMUM REQUIREMENTS- - f . i a• O REQUIRED PRIOR TO ORDERING MATERIAL.NEW FRAMES TO BE FACTORY FINISH CLEAR ANODIZED 10 28 13 BREAK COUNTER INDIVIDUAL ROOMS WITH AN EXHAUST REQUIREMENT GREATER THAN 250 CFM,SHALL HAVE A � V -C ALUMINUM. 1. PAPER TOWEL DISPENSERS,SURFACE MOUNTED(KITCHEN/BREAK ROOM)BOBRICK B-262 ROOFTOP MOUNTED FAN. I l IVI ® .. W ai 4. FIELD VERIFY EXISTING DOOR,FRAME AND HARDWARE FINISH PRIOR TO ORDERING. ALL NEW DOORS, 1 WI O 1044 16 FIRE EXTINGUISHERS 23.HVAC TESTING. , = U O FRAMES AND HARDWARE TO MATCH EXISTING BUILDING STANDARDS. a. CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES,COMPONENTS, IllilO 1. FIRE EXTINGUISHER 2A10 BC {WALL MOUNTED OR IN SEMI RECESSED CABINET A5 INDICATED ON PLAN) �� < c\j CD 5. ALL INTERIOR DOORS SHALL BE SOLID CORE WOOD UNLESS NOTED OTHERWISE. EQUIPMENT AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH 6. DOOR HARDWARE SHALL BE SCHLAGE AL SATURN OR D RHODES SERIES U.N.O. 2. FIRE EXTINGUISHER CABINET: JLINDUSTRIES ACADEMY SERIES MODEL#C1027V10. APPROVED PLANS AND SPECIFICATIONS. 'd. � � 7. ALL DOOR HARDWARE SHALL BE INSTALLED WITH A 2 314"BACKSET. 12 00 00 FURNISHINGS b. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN 1 -"� DATE. 2018-08-30 1. CLEAN/REFURBISH EXISTING BUILDING STANDARD BLINDS AT ALL EXTERIOR GLASS, ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. `__ _ __ _ _ 8. DOOR FINISH SUBMITTAL:CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR DOOR FRAMES,DOOR PERMIT/BID SET HARDWARE AND DOORS AS WELL AS A CONTROL SAMPLE OF THE FINISHED DOOR SKIN W/STAIN AND FINISH 12 23 16 CABINET SPECIFICATIONS c. A COMPLETE COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND + FILED WITH PACTRUST. -- , .. APPLIED(IF NEW DOORS ARE BEING PROVIDED). BEFORE FINISHING OF DOORS IS COMMENCED ARCHITECT '� REVISION SHALL APPROVE CONTROL SAMPLE. FINISHED PRODUCT IS SUBJECT TO REJECTION BY ARCHITECT IF THIS 1. ALL CABINETRY TO BE INSTALLED OVER FINISH FLOOR AT ALL RESILIENT FLOORING LOCATIONS. 24.PROJECT CLOSE OUT DOCUMENTS REQUIRED: SAMPLE.PROCESS IS NOT FULLY ADHERED TO AND FIELD PRODUCT DOES NOT MATCH THE APPROVED CONTROL 2. AWI CUSTOM GRADE STANDARDS FOR CASEWORK AND COUNTER TOPS U.N.O a. AutoCAD FILE SHOWING AS-BUILT INFORMATION. �.. BUILDING PLAN - SECOND FLOOR r-. 5 3. HIGH PRESSURE LAMINATE(P-LAM HPL)ALL EXTERIOR SURFACES, INCLUDING 4"TOE KICK. EDGE BANDING b. ELECTRONIC PDF FILE OF THE AutoCAD FILE ABOVE. CITY Of TIGARD 9. ALL INTERIOR GLAZING SHALL BE TEMPERED. (MATCHING PVC ACCEPTABLE),FIN ENDS, DOORS,AND LIGHT VALENCE ETC. UPPER CABINET BOTTOMS 10.DEAD BOLT LOCKS AT NEW EXTERIOR DOORS TO BE INSTALLED WITH A SCHLAGE MORTISE DOUBLE OPTIONAL HPL FINISH,STANDARD MELAMINE FINISH. OPEN CABINETS OPTIONAL HPL FINISH,STANDARD c. HARD COPY OF AutoCAD FILE ABOVE. Approved by Planning A- SCALE 1` = 50' 1. CYLINDER 20-013C "C'KEYWAY;SOLID BRASS;WITH ADAMS-RITE CAM AND COMPRESSION RING 1 118"LENGTH MELAMINE FINISH. d. OPERATIONS MANUALS FOR ALL EQUIPMENT, INCLUDING T-STATS. f" t(� T-I 2. WITH HARDENED CYLINDER GUARD RING KEEDEX K-24. FINISH TO MATCH BUILDING STANDARD, 4. TOE KICK PLYWOOD 4"H WITH P-LAM COVER e. COLORED ZONE MAP WITH THERMOSTAT LOCATIONS INDICATED. 10-`, Date: 11.PATCH AND REPAIR ALL HOLES OR DAMAGE TO EXISTING STORE FRONT WINDOWS AND DOORS.TOUCH UP 5. DOORS AND DRAWER FRONTS PLASTIC LAMINATE OVER 11/16"PARTICLE BOARD WITH MATCHING P-LAM OR 26 00 00 ELECTRICAL, : DESIGN 1 BUILD Initials: St- 3. FINISH FOR AS NEW LOOK. PVC EDGES. 4. 09 00 00 FINISHES 6. MELAMINE(LOW PRESSURE LAMINATE/LPL)ALL INTERIOR AREAS,DRAWER PARTS,SHELVING ETC. GENERAL OFFICE COPY GENERAL 1. ALL ELECTRICAL FEEDS TO OUTLETS,SWITCHES, ETC. MUST BE VERTICAL DROPS FROM ABOVE EXCEPT FOR r 7. FLUSH OVERLAY/FRAMELESS STYLE CONSTRUCTION. HORIZONTAL RUNS UNDER WINDOWS AND RECEPTACLES ON THE SAME STUD. 5. 1. CLEAN,SEAL AND WAX ALL RESILIENT FLOORS PER MANUFACTURERS SPECIFICATIONS. 8. THERE SHOULD BE 118"OR LESS GAP TOLERANCE BETWEEN DOORS AND DRAWERS. ABBREVIATIONS 2. SUBMIT SAMPLES OR DRAW DOWNS FOR THE FOLLOWING: 2. ALL ELECTRICAL FEEDS TO OUTLETS AND DATA BELOW WINDOW SILLS TO BE ROUTED THROUGH BUILDING • 9. HINGES-BLUM#75M3580,110 DEC.SELF CLOSING CLIP ON(OR EQUAL). SHELL WALLS. DO NOT FEED FROM PERPENDICULAR INTERIOR PARTITIONS. 6. a. FLOOR COVERINGS,BASE AND TRANSITION STRIPS CB CERAMIC TILE BASE CITY OF TIGARD_ 10.DRAWER SLIDES-BLUM #230M SERIES EXTENSION(OR EQUAL)75 LBS. MIN.FOR STANDARD DRAWERS. 3. ALL NEW ELECTRICAL DEVICES TO BE WHITE 7. b. PLASTIC LAMINATES ACCURIDE#4032(OR EQUAL)HD/FULL EXT 150 LBS.MIN.FOR HD AND FILE DRAWERS. 4. PROVIDE LABELS AT EACH ELECTRICAL RECEPTACLE IDENTIFYING CORRESPONDING PANEL AND BREAKER. CFCI CONTRACTOR FURNISHED, CONTRACTOR INSTALLED REVITW�D �:{}R GO1)L COMPLIANCE (INCLUDINGCASEWORK) 5. PROVIDE TYPEWRITTEN UPDATED SCHEDULE AT PANEL TO IDENTIFY CIRCUIT BREAKERS. CPT-# CARPET c. ALL NATURAL WOOD DOORS AND 11.PULLS-96 MM C-TO-C WIRE PULLS. FINISH TO MATCH DOOR HARDWARE. 8. CTd. PAINT 12.GENERAL CONTRACTOR TO PROVIDE CABINET MAKER WITH SINK TEMPLATE(SPEC SHEETS)FOR EACH SINK. 6. VERIFY ELECTRICAL METER AND TAG METER WITH THE TENANT'S ADDRESS OR SUITE NUMBER. METER E (E) CERAMIC TILE �r�PnVC(� SINK CUTOUT SHALL BE DONE IN SHOP WHEN FEASIBLE AND BEFORE BACK SPLASH IS INSTALLED IN ALL E EXISTING N� e. HARDWARE IDENTIFICATION NUMBER AND TENANT ADDRESS INFORMATION SHALL BE GIVEN TO PACTRUST PRIOR TO • ��(-� / • CASES TO ALLOW CUT OUT TO BE POSITIONED PROPERLY. ALL RAW EDGES OF CUT OUT AND BACK SPLASH ETR EXISTING TO REMAIN f�' !7� TENANT'S MOVE IN. ` U U,� DRAWN BY: 3. FINISH FLOORING TO EXTEND UNDER ALL NEW CASEWORK. TO BE SEALED. MINIMIZE COUNTERTOP BUILD UPS AT FRONT AND BACK OF SINK CUT OUT TO WC WALL COVERING Pert»i 1 #- ACCOMMODATE PLUMBERS SINK CLAMPS CLEARANCE. 7. ELECTRICAL CONTRACTOR TO PROVIDE EMERGENCY LIGHTING IN EXIT PATH SHOWN ON PLAN EQUAL TO M.W.N. 4. PROVIDE A TRANSITION STRIP WHERE EVER TWO DIFFERENT FLOOR MATERIALS MEET 1-FOOT CANDLE, GWB GYPSUM WALL BOARD All(? " •tis; _ ,.%r._-ter 5. PROVIDE SCHLUTER METAL TRIM AT ALL EXPOSED EDGES OF TILE(EXCEPT AT BULLNOSED EDGE)OF TILE 13.WORK/COPY/STORAGE CABINETS-BASE CABINETS WITH P-LAM TOP ON PARTICLE BOARD DECKING. SCRIBE N (N) NEW (CERAMIC,QUARRY OR PORCELAIN} COUNTERTOPS TO WALLS. ALL CABINETS OPEN MELAMINE STANDARD INTERIORS WITH DRAWERS,U.N.O. 8. EXIT LIGHTS: RUUD LIGHTING"PLASTIC LED EXIT SIGN"MODEL EXPBURWH RED LETTERS,WHITE HOUSING, 1GOCi SW r�- ` ?C UPPERS AT 15"D X 30'H -ATTACH UPPERS TO WALL WITH FRENCH CLEAT. BASES AT 24"D X 36"H. P-LAM AT WITH BATTERY BACKUP. PGWB PAINTED GYPSUM WALL BOARD Step �' _ . 09 21 00 GYPSUM BOARD TOE/BASE, ALL SHELVES ADJ. HOLES AND POST(1 AT BASE, 1 AT UPPERS). 9. WHERE NEEDED,CONTRACTOR TO FURNISH AND INSTALL NEW DRY TYPE TRANSFORMERS TO PROVIDE 1,�;OTS OPEN TO STRUCTURE ]�a49,-3-: I �a�0 GENERAL 14.WORK COUNTER TOPS-COUNTER TOPS WITH P-LAM ON PARTICLE BOARD DECKING. SCRIBE COUNTERTOPS 208V/120V POWER FROM THE 480V/277V SYSTEM. SIZE TO BE BIDDER DESIGN. PL-# PLASTIC LAMINATE • .:? GENERAL NOTES - NEW *-D 48c A. IT SHALL BE THE CONTRACTOR;S AND/OR THE SUBCONTRACTOR'S D MICHAEL � RESPONSIBILITY TO VERIFY ALL DIMENSIONS, DETAILS,AND JOB SITE WIRE THWANG ,� CONDITIONS PRIOR TO PROCEEDING WITH THE WORK,AND REPORT ANY y F -- € l 1- - DISCREPANCIES TO THE ARCHITECT BEFORE STARTING CONSTRUCTION. • A B. REFER TO SHEET A-4 FOR WALL TYPES ��1 PORTLAND,OREGON czt AO r i, q�' OF �� �: C. REFER 70 SHEET A-2 FOR DOOR SCHEDULE. [� O� � 1 � t D. REFER TO SHEET A-4 FOR FINISH SCHEDULE. — I W1I , • E. REFER TO SHEET A-1 FOR GENERAL PROJECT SPECIFICATIONS. PROJECT # - O F. REFER TO SHEET A-3 FOR REFLECTED CEILING PLANS. i• I G. ALL ELECTRICAL DEVICE COVER PLATES TO BE WHITE.ALL EXISTING COVER I x PLATES TO BE CHANGED TO WHITE. I IP 1 OFFICE 7`-' OFFICE H. ALL ELECTRICAL DEVICES TO BE WHITE.ALL EXISTING DEVICES TO BE �� `�, 4 �07 x �6 CHANGED TQ WHITE, --I II II I— OFFICE ► 14'.7'x ta'-r s-7•x 14'-2' • 208 ► <4 © � — _ , I PA ► CPT-1 ► '�• x 14'-T x 11'-x' y{ I X in ► 0) / X / ' X2082 207 206 • IX > . • — 1 ► g o I J F OFFICE ► OFFICE 01MI. MIOI. , a c '4 I U IIXXXX\XXXXXX <9- ' XX.XXXXXXXX; KEYED NOTES O o 210 ......► [2091 x s's" x Z . 0.. CPT-1 _► CPT-1 1 i—7"�s 5-fi' ►y ——.9'-B'--x-11'-7L X D CV ► ?C- I T O DASHED LINES INDICATE LOCATION OF SYSTEMS FURNITURE. o X 204 SYSTEMS FURNITURE TO BE PROVIDED BY OWNER. CQ Y ► X �' CIRC. a ► �' CPT-1 VCT l'CT O NO CHANGE TO EXISTING CASEWORK. N ► X 205 5'-fi'x 5'0 2 Q N 210 ► 209 x 20.-,CPT-1• 3'S ((204) ; 1 O rn i- ► x n O ALIGN CL NEW WALL WITH CL OF EXISTING WINDOW MULLION. X f - - - - - - - - - - _ AN xxxxxxx <XXX) �XXXXXXXXxxX; P O o ► X c? I A O ALIGN CL NEW WALL WITH CL OF EXISTING COLUMN WRAP. C'7 XXXXXXI�-` s 2 -\ i 0 0 O CO I; • " X 5 REMOVE EXISTING WALLS IN THEIR ENTIRETY TO EXTENTS 0 Q N , Z t° X O INDICATED. 03 co J 4' ' 4' 4' 3' 4'-10" 5' 18'-4"� L 6O FLOOR MONUMENT. 0 t ct j c j =! to to 'I 1 �, 1 — ` 2 Loris m IxXXXXXXXXI I XXXXXXX I- - - � ----I 1 -s• O - Sif. LG. CONF. Y• I— —1 CPT-1 t. ., t 11'-2 x 15'-1' iiiiiP' : . GI F 0X O EQ EQ 1il OPEN OFFICE 1 X203 CPT-12 PT21 21 '.d O O © 31'-2'x 25'-6' ._. . . c I i'<NI IKX\ �— X A(g) � XXxIF- 1[\2X} — X I 202 - n CP 1MIC)111 I . O LUNCH/WORK ►X RECEP. CONSTRUCTION LEGEND NEW 291t-;-.1 6 I Ank X X201 1 LVT 1y'7 x g to T O T X CPT-1 EXISTING TO REMAIN IIM A-4 X 12-5'x 16-2' X1113 • A L� SM. CONF. I I �� NEW STANDARD WALL WITH INS. © 1 X, j CPTT� r'-- 1___-—- ©� NEW STANDARD HALF WALL3 \T-5" I ID �XX g-5'x 11-6' X 1 I DUPLEX RECEPTACLE to c \oFJ BOX `-�X X O 45_5 45/66 f \.t ,�� I X X I ` _> - 1 ®J ] © FOURPLEX RECEPTACLE _ _ _,_ _ 45 X `-J X L A l' a� DEDICATED OUTLETrii o - T T _� dib , X 9'-5' X -/ f 4 r� dl V EXISTING ELECTRICAL TO REMAIN 61 r171111. ai 1 ' `• U; --0 I I 0 THERMOSTAT 0. a UI / TEL/DATA MUD RING WITH PULL STRING ^^ .____ _ _ -- -- --- 7,"4,32,), r-i - — I� / • e; '.., \ . _.__ _ - ' © ELECTRICAL PANEL / • . 7----/ ® POWER J-BOX✓201 NOQ �O �-- - rl___ U �� FLUSH MOUNT FLOOR MONUMENT W/POWER AND DATA Q 6777TJ'1 is F'' ORELITE TYPE.SEE DETAIL 10/A-4. r n a N 2 OVERALL BUILDING PLAN �J W �' ED cn1W ¢ A-1 114" = 1'-o" UY 0- N N._ DOOR SCHEDULE Qap � ado DOOR DATA FRAME DATA HARDWARE W U- � 2 Fire Rating Remarks Mark = a N o . Mark Door Size Thk Core Veneer Finish Hand Type Frame Depth Hardware Manufacturer Finish Function °- r a 20 MIN DATE: 2018-08-30 201 3'-0" x 9'-0" 1 3/4" SC SAPELE CHERRY Right • ALPHA 4 718" LEVER (D SERIES) ETR ETR ETR 3 201 PERMIT/BID SET 202 3'-0" x 9'-0" 1 3/4" SC SAPELE CHERRY Right ALPHA 4 718" LEVER (D SERIES) SCHLAGE 626 SATIN CHROME AL1 OS 1 202 REVISION 203 3'-0" x 9'-0" 1 3/4" SC SAPELE CHERRY Right ALPHA 4 718" LEVER (D SERIES) SCHLAGE 626 SATIN CHROME AL1OS -- 203 . 204 3'-0" x 9'-0" 1 3/4" SC SAPELE CHERRY Left ALPHA 4 718" LEVER (D SERIES) SCHLAGE 626 SATIN CHROME AL53PD 2 204 1. 206 3'-0 x 9'-0" 1 3/4" SC SAPELE CHERRY Left ALPHA 4 7/8" LEVER (D SERIES) SCHLAGE 626 SATIN CHROME AL53PD -- 206 2. 3. 207 31-0" x 9'-0" 1 314 SC SAPELE CHERRY Left ALPHA 4 718 LEVER (D SERIES) SCHLAGE 626 SATIN CHROME AL53PD (2) 31-0" x 9'-0" INTEGRAL SIDELITES 207 4. 208 3'-O" x 9'-0" 1 314" SC SAPELE CHERRY Right ALPHA 4 7/8" LEVER (D SERIES) SCHLAGE 626 SATIN CHROME AL53PD (2) 3'-0" x 9'-0" INTEGRAL SIDELITES 208 5 209 3'-0" x 9,-0" 1 3/4" SC SAPELE CHERRY Left ALPHA 4 7/8" _ LEVER (D SERIES) SCHLAGE 626 SATIN CHROME AL53PD 1 209 . 6. 210 3'-0" x 9'-0" 1 3/4" SC SAPELE CHERRY Right ALPHA 4 7/8" LEVER (D SERIES) SCHLAGE 626 SATIN CHROME AL53PD 1 _ 210 7. NOTES: 8. I. 3'-0" x 9'-0" INTEGRAL SIDELITE, TEMPERED DRAWN BY: 2. UNDERCUT DOOR TO ALLOW FOR AIR FLOW M.W.N. 3. PREP DOOR FOR ELECTRIC LOCKSET. TENANT TO SUPPLY AND INSTALL LOW VOLTAGE AND CARD READER. A- 2 . GENERAL NOTES - NEW �E� A/9le A. IT SHALL BE THE CONTRACTOR;S AND/OR THE SUBCONTRACTOR'S �� MICHAEL � crt RESPONSIBILITY TO VERIFY ALL DIMENSIONS,DETAILS,AND JOB SITE WIRE THWANG CONDITIONS PRIOR TO PROCEEDING WITH THE WORK,AND REPORT ANY n DISCREPANCIES TO THE ARCHITECT BEFORE STARTING CONSTRUCTION. • FI-----II I B. REFER TO SHEET A-4 FOR WALL TYPES (-f31 PORTLAND,OREGON ..i /9� 5851 C. REFER TO SHEET A-2 FOR DOOR SCHEDULE. c 0 O� — 1 U e `_ .—.1 I, 11 I , D. REFER TO SHEET A-4 FOR FINISH SCHEDULE. • X IX i : E. REFER TO SHEET A-1 FOR GENERAL PROJECT SPECIFICATIONS. . —j I II77_, t .c....v, F. REFER TO SHEET A-3 FOR REFLECTED CEILING PLANS. PROJECT # G. ALL ELECTRICAL DEVICE COVER PLATES TO BE WHITE.ALL EXISTING COVER PLATES TO BE CHANGED TO WHITE. • • • - • • /� • H. ALL ELECTRICAL DEVICES TO BE WHITE.ALL EXISTING DEVICES TO BE f CHANGED TO WHITE. — -i r° • '- T - -71I. HVAC LAYOUT IS SHOWN FOR SUGGESTED LAYOUT.ACTUAL LAYOUT TO BE / DONE BY HVAC CONTRACTOR. • - I . L__.h--- -- ---.-- ._. . ._1._ v R r RLJ J. FIRE SPRINKLERS TO BE ADJUSTED PER NEW ROOM CONFIGURATIONS.FIRE Q _ ____T SPRINKLER CONTRACTOR TO PROVIDE NEW,CODE COMPLIANT LAYOUT. • X 11 • _ ! R _ R � o �. /71 0 co 1,_._.. II. If I' F----Ih HI 7 I iS I ZI > N It V--N I 000 Y . • C6 a a Q (\I a /".\\\>. { n 1 1._ , ,r-F- -R. p _1 . _ , I 1.1. 1 _ _ cndf.c.:,p) r...: IM n3 u) < N N Z _C oplcflc0 0 • X X . , 0j2CO .m.r 8 Lo no i 1 r— / / _ / /:z 1 A 0 "X K--71 I • ' I • I I IL__N .. < A /R T 1 .. • - _ • L---z( • -_ _ - ,74/1 (4») -1 ,.L-- , - - J I ' 11 1 L _ _ I X., ,____1• _ , RA0 0 _ I- _ CO _____ , , 3 • I- - 71 7 _ _ _,_ • , /, 0 r 10 Q • LI:1 0 0 • �n�r, / \ • _ _ -- _ __ Om CLo • o � [ Lo H 2 OVERALL BUILDING PLAN N 0 w CD A-1 1/32" Q.cnz < _ ��_a�� CONSTRUCTION CEILING NEW Z_ v ® RELOCATED 2 X 2 LED.FIXTURE Q Q N LITHONIA 2BLT,CURVED LENS n- N . - mum (E)2 X 2 LED.FIXTURE TO BE MOVED OR REMOVED. LLQ Co X II (E)2 X 2 LED.FIXTURE 0 LITHONIA 2BLT,CURVED LENS TO REMAIN W a 0- • 0 (E)RECESSED LED LIGHT LLc„)O g E. 6' (N)SUPPLY DIFFUSER Q N O � H 112 (N)RETURN DUCT �.�_.�_ DATE: 2018-08-30 Q THERMOSTAT PERMIT/BID SET ® EXHAUST FAN REVISION 2TILE • SPRINKLER HEAD 1. 2018-10-01 A e EXIT SIGN(LED RED) 2. O SMOKE DETECTOR 3. ® RECESSED CEILING EMERGENCY LIGHTS 4. 0 CEILING MOUNTED MOTION SENSOR 5. ® WALL MOUNTED LIGHT SWITCH WITH MOTION 6. SENSOR AND DIMMING CONTROL. A 7. Q J-BOX ABOVE CEILING WITH 5'-0"WHIP FOR CONNECTION PROJECTOR. 8. DRAWN BY: M.W.N. INDICATES COMMON PATH OF TRAVEL REQUIREING EMERGENCY I LIGHTING EQUAL TO 1-FOOT CANDLE. 2 X 2 SUSPENDED CEILING SYSTEM: FULL 24"TILE THIS SECTION ,---leATTACHED EDGE SEISMIC EXPANSION JOINTS � I M A_ 3 .. UNATTACHED UNATTACHED EDGE u■■E GRID MAIN - ._.M. • • Q;ED A� 114"FILLER FOR I ! I FLOOR AND/OR ROOF STRUCTURE �� C� 20 GA 3 518 MEAL STUD BRACING TO ROOF ARMSTRONG BERC2 CLIP(AS ALTERNATE MEANS OF CONSTRUCTION \� MICHAEL /14 9D CflN01710N STRUCTURE AT 10'-0'OC TO BUILDING STRUCTURE /I I FOR THIS PROJECT.) • I WIRE TNWANG ABOVE FOR WALLS LONGER THAN 12'-D"WITHOUT � 3 o ADDITIONAL HANGERS AT ALL MAINS WITHIN 8"OF THE PERIMETER LC-.19:1-1[.....).A � :I—I ' INTERSECTING WALLS. FASTEN EACH ENO WITH(1) 440r #8 SHEET METAL SCREW WHERE REQUIRED / / ' u APPROVEDVERTICAL STRUTAT12'0"O.C. EA.WAYB ILDIN GWITHIN�� LITE KIT WHERE SPECFIED 6'-O"OFTHEPERIMETROFEACHCEILINGSECTION.SEESTRUTDETAIL PORTLAND,OREGONIIII 518"GYP.BD CAPFRAME TO MATCH DOORSTRUTSATFIXTED EDGESNOTATTACHED TO THE BUILDING TO ,� 5851 �- ri TYPICAL STUDTFLL HAVE 4 WAY LATERAL BRACING FROM THE MAIN RUNNER TO THE !� .L�..., SUSPENDED CEILING CORNER BEADS PROVIDE HC SIGNAGE NEW 0 Illiiir BUILDING STRUCTURE ABOVE. F ' I p 6"zy " o AND EXISTING HC RR'S KROY l O #2835207 BLACK(MEN)KROY �/ #2835209 BLACK(WOMEN) BLOCKING TYPICAL AT FASTENING POINTS 2'a" 2 ' /1 // PROJECT # Z ' � 0°1 TYPICAL TRACK O . 3 518"MTL.STUDS 24'O.C. C w �+�+ r` o (IN REMODELS SIZE STUDS TO ALLOW REUSE INSTALL STUDS WITH SAME o w / N ADDITIONAL SWITCH GANG / r c.3 < i- 111 OF BLDG.STD.DOORS AND FRAMES) DIMENSION(10"MIN.}FOR a / LOCATIO I I 3-518"MTL.STUDS @ 24'O.C. BRIDGING ALIGNMENT 4 0 _ 518'GYP.BRD,BOTH SIDES -- 518"GYP.BAD.BOTH SIDES W I 1- CENTER ,;8" CROSS MEMBERS BETWEEN MAIN fili LINE OF STUD to CENTER LEVE OF STUD z � MAX RUNNERS 2"x2"x114'T,S.ON{2)112"x6"x318"PLATE x w WI(2)i12'PARABOLTS MID WALL AND L. ¢ i= 6'-0"MAX MAIN RUNNERS AT 4'-0"O.C. - ' SUPPORT WITH#12 WIRE AT 4'-0"O.C. II ci iv ELECTRICAL = OR WITH#10 WIRE AT 5'-0"O.C. Q FEE STANDING ENDS pN 6'-0'O.C. 11111.° s (4-0'O.C.ON TRANS.WALLS) 01111111111111114010POWDER DRIVEN w ` 4 w z w ., - ANCHORS AT 12"O.C. \ OUTLET OR U COUNTERSLOPE HANGERS IF MORE CD , 014"RUBBER RASE TYP, � J-BOX i � � �Y` � THAN 1:6 OUT OF PLUMB ;,,_ . or ATTACH BOTTOM TRACK TO FLOOR WITH 4"RUBBER BASE TYP. (1)#10 16 SCREW \ — low SECURE ALL HANGERS TO BLDG. al•- oil , POWDER DRIVEN ANCHORS AT 24'O.C. UNDERCUT DOOR AS` °° 6Th 4 STRUCTURE OR A TRAPEZE FOR PER STUD FLANGE o REQUIRED TO CLEAR a'' DUCT AND/OR PIPE WORK FINISH FLOOR O FINISH FLOOR I FLOOR FINISH \ I NOTE: CEILING SYSTEM TO BE USED SHALL BE CLASSIFIED AS"HEAVY •+--' O I I I f i f DUTY". ALL CONNECTION DEVICES TO BE IBC APPROVED TYPE AND 0 Cr) HAVE 100#CAPACITY Z .1 TYPICAL WALL SECTION 4 LOW WALL DETAIL 3 WALL BASE DETAIL 4 MOUNTING HEIGHTS 5 CEILING BRACING DETAIL icio A-4 SCALE 1" = 11-0" A-5 SCALE 1" - 1'4° A-4 SCALE 3" = 1'-0" A-4 SCALE 112" = 1'-0" A-4 NOT TO SCALE (13 EQ N Q ALIGN TOP OF FRAME a a a 20 GA 3 518'METAL STUD BRACING TO ROOF FRAME. — - c') t� CO WITH TOP OF DOOR CM STRUCTURE AT 10'-0'OC TO BUILDING STRUCTURE 8�"MAX. 8" MAX N 0 4 I; Ur • ABOVE FOR WALLS LONGER THAN 12-0 WITHOUT / I 96" INTERSECTION WALLS. FASTEN EACH END WITH(1) 41 Iz -"' #8 SHEET METAL SCREW 41/4 (I-- , 1.. a � ' 1r � O OR-11 BATT INSULATION 4'CENTERED OVER WALL \ / \ 1 \ 75 LC)CD cc 11?�'1� ROOF DECK "1 A - C r 0 m ,'11'11 tat& 4:000' 11'. SUSPENDED CEILING minI OR BEAM d „/"- 1/2. / a �. e i '-.. (4 o Zo BLOCKING TYPICAL AT FASTENNG POINTS ° ° .. Q co SUSPENDED CLG ASSEMBLY i] ,m 4 [i .a 1 110-4 3 11'2 BATT INSUL. ELECTRICAL AND DATA OUTLETS ARMSTRONG BERC2 CLIP e o ARMSTRONG BERC2 CLIP ® / SHOULD BE OFFSET SO THEY ARE ATTACHED TO GRID UNATTACHED TO GRID / 3 518"MTL.STUDS 24'O.C. NOT BACK TO BACK. I ATTACHED WALL UNATTACHED WALL ' IN REMODELS SIZE STUDS TO ALLOW REUSE HANGER WIRE WA PUTTY PAD SHOULD BE PLACED AROUND _s.,, STRU OF BLDG.STD.DOORS AND FRAMES EACH OUTLET. MIIIMIrill .I, I e-MAX AND/ SPLAY WI Ery PERS �� 518'GYP.BRD.BOTH SIDES 3-518 MTL. STUDS @ 24' O.C. ! MMIIAIMIIIM HANGER WIRE 'II y�� CENTER LINE OF STUD7 CEILING BRACING DETAIL 20 GA 3 518" METAL STUD BRACINGPOP-RIVET 'en I , CROSS TEE E' MAIN BEAM CROSS TEE 00 �. III TO ROOF STRUCTURE AT 10'-0" - o 1' _ w •' 4A /, /��� ,' OCWI(1)#8SHEETMETAL noI oo / ` ° 0000 00 000 O O O o y� O O -.! O O O O O SCREWS AT EACH END. BRACING a n A n (p o; • TO BE PROVIDED WHERE DISTANCE - J '.t \ 1 FREE END FIXTED END . 4"RUBBER BASE TYP. BETWEEN PERPENDICULAR INTERSECTING t ACOUSTIC BATT INSUL.PER PLAN WALLS OR HORIZONTAL BRACING T!8"ANGLE MOLDIN 11' \ (FULL 24" TILE SECTION) CV I 3-518"MTL STD WITH — , ATTACH BOTTOM TRACK TO FLOOR WITH r` 518"GYP EA SIDE rob- ING POWDER DRIVEN ANCHORS AT 24'0.C. (1)LAYER 518"GYP BD.EA SIDE BETWEEN WALLS EXCEEDS 12'-0"OC POP-RIVET 2" / UNATTACHED2"ANGLE THISSIDE BELOW RELITE. • St / FINISH FLOOR EXPANSION JOINT -- NOTE: CEILING SYSTEM TO BE USED SHALL BE CLASSIFIED AS"HEAVY DUTY". \ ALL CONNECTION DEVICES TO BE IBC APPROVED TYPE AND HAVE 100# CAPACITY 6 WALL SECTION WITH SOUND INS. 7 ELECT. OUTLET AT SOUND WALL 8 WALL BRACING DETAIL 9 CEILING SEISMIC JOINTS . EMI A-4 SCALE 1" = 1'-0" A-4 SCALE 1" = 1'-0" A-4 SCALE 3" = 1'-0" A-4 SCALE 3" = 1-0" `' , 01) - - - L 1 3 ALPHA RELITE FRAME WI TEMPERED GLAZING FINISH SCHEDULE At WALLS . 1.71 .. RM# NAME FLOOR BASE CEILING CLG. REMARKS RM# ini NORTH EAST SOUTH WEST HT. 10 RECITE ELEVATION4 201 RECEP. CPT-1 RF PT-1 PT-1 PT-1 PT-1 SAT 8'-6" -- 201 . . A-4 1/2" = 1'-0" 202 SM. CONI. CPT-1 RF PT-1 PT-1 PT-1 PT-1 SAT 8'-6" -- 202 — ._ 203 LG. CONF. CPT-1 RF PT-1 PT-1 PT-1 PT-1 SAT 8'-6" -- 203 1 O N O 204 IT VCT RC PT-1 PT-1 PT-1 PT-1 SAT 8'-6" -- 204 11 w 205 CIRC. CPT-1 RF PT-1 PT--1 PT-1 PT-1 SAT 8'-6" --- 205 F= 206 OFFICE CPT-1 RF PT-1 PT-1 PT-1 - PT-1 SAT 8'-6" -- 206 w } 207 OFFICE CPT-1 RF PT-1 PT-1 PT-1 PT-1 SAT 8'-6" -- 207 Ci w -• 208 OFFICE CPT-1 RF PT-1 PT-1 PT-1 PT-1 SAT 8'-6" -- 208 z v 209 OFFICE CPT--1 RF PT-1 PT-1 PT-1 PT-1 SAT 8'-6" -- 209 J < a ti 210 OFFICE CPT-1 RF PT-1 PT-1 PT-1 PT-1 SAT 8'-6" -- 210 — _c rn 10'-7" LL a c o 211 LUNCH/WORK LVT RC PT-1 PT-1 PT-1 : PT-1 SAT 8'-6" --- 21 y / (8) EQ CABINETS 212 OPEN OFFICE CPT-1 RF PT-1 PT-1 PT-1 PT-1 SAT 8'-6" -- 212 LLl 0 ' Q N O FINISH MATERIALS 12 ALL FINISHES MUST BE SUBMITTED TO PACTRUST PRIOR TO INSTALLATION. DATE: 2018-08-30 CARPET PLANK TILE: .. /\ n \ \ PERMIT/BID SET CPT-1 MOHAWK GROUP PTR-CARPET PLANK BT389 I QB389-358 CLASSIC RIDGE, FLEXLOK CONNECTORS I " II ii • i1 / \ / \ / \ ' REVISION LUXURY VINYL TILE , , I LVT MOHAWK GROUP GLORY ENTRY- MATUTO-959 GREY GRANITE I ADJ. SHELF ADJ.SHELF ADJ.S ELF V ADJ.SHELF }}' in • I\ I I I CABINET ACE /I 1. VINYL COMPOSITE TILE (VCT) } i i+ AqD EQaES L 1 - 2. VCT ARMSTRONG STANDARD EXCELON 51839 FORTRESS WHITE 12"x 12"x 1/8"THICK I I I / I I / I I " ' • I � �/ II I' II II I �" II �� II ., L II y I 3. BASE .J L - \ 4. RF FLEXCO 4" FLAT RUBBER BASE, 071 BLACK/BROWN,AT ALL CARPET AREAS. RC FLEXCO 4"COVE RUBBER BASE, 071 BLACK I BROWN,AT ALL HARD SURFACES. 5 N pp PAINT \ -- 0 -- — — N6. PT-1 MILLER 110-4 ACRO PURE ULTRA-LOW VOC 0017 LUNA MOON,SATIN LATEX. PT-2 'MILLER 110-4 ACRO PURE ULTRA-LOW VOC 0563 VIGILANT, SATIN LATEX (ACCENT COLOR) .. ..PL-.2 , 7. \' T LAMINATE: 8. ,t1 Ir iII I I r PL-1 FORMICA5882-58 CITADEL WARP ALL FACES ;n i �I` I i t � t 7"-N. • ICABINEFACE I IPL-2 FORMICA6920-58 MINERAL SPA(COUNTER, B.S.AND SELF-EDGE.) � I Z N I , I I I , / I ANQ EDTES��1 I I I 11 I I ,a--C.4 DRAWN BY: y ADJ.SHELF 17 ADJ.SHELF NI ADJ. HELFADJ. SHELF I CAB PULLS (MATCH EXISTING) >r N M.W.N. 1I N / II N V II N N .Z EXISTING COUNTER TOP: " I I " "v SOLID SURFACE COUNTERS (EXISTING TO REMAIN) '�� L� 1 �� SSC RENTAL QUARTZ BQ400P SEASHELL POLISHED COUNTER, B.S. AND SELF-EDGE \.- N DOORS, HARDWARE AND FRAMES 1O'-7" HARDWARE 626 SATIN CHROME (8) EQ CABINETS FRAMES INTERIOR DOORS-ANODIZED ALUMINUM ./ / A.4 SUITE DOOR- EXISTING FRAME TO REMAIN CABINET HARDWARE HINGE: BLUM CLIP 120 (CONCEALED) 11 CABINET ELEVATION DRAWER SLIDES : BLUM 230 (3/4'EXTENSION) i.-V 1/2" = ('-0"