Loading...
Plans (89) NM_ MST2018-00330 114409 SW 169TH AVE ® MST2018-00331 114433 SW 169TH AVE MST2018-00332 114449 SW 169TH AVE MST2018-00333 114471 SW 169TH AVE MST2018-00336 14479 SW 169TH AVE MiTeW MiTek USA, Inc. 7777 Greenback Lane Suite 109 Citrus Heights, CA, 95610 Telephone 916/676-1900 Re: PL18-351_UPPER Fax 916/676-1909 POLYGON The truss drawing(s)referenced below have been prepared by MiTek USA,Inc.under my direct supervision based on the parameters provided by Pacific Lumber&Truss Co.. Pages or sheets covered by this seal: R55803543 thru R55803558 My license renewal date for the state of Oregon is June 30,2019. 0,0 R Opp, S���NG F EFq s% 4(. 2 87022PE r' N N -y �Ati9 j, OREGON SUN CIO ccMaER \` A. He?, • . . : '. i i October 12,2018 Hernandez,Marcos IMPORTANT NOTE:Truss Engineer's responsibility is solely for design of individual trusses based upon design parameters shown on referenced truss drawings. Parameters have not been verified as appropriate for any use. Any location identification specified is for file reference only and has not been used in preparing design. Suitability of truss designs for any particular building is the responsibility of the building designer, not the Truss Engineer, per ANSI/TPI-1, Chapter 2. Job Truss Truss Type Qty Ply POLYGON R55803543 PL18-351_UPPER F01 Floor 2 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 8.130 s Mar 11 2018 MiTek Industries,Inc. Fri Oct 12 12:39:55 2018 Page 1 ID:5eV?tdjYilz0X2xysiFDVpzsmUO-cjFbVxm9cGOxfBG7fyJ7BOPOk2RBgV5Ci 1 QEw6yU9GI I 1-9-12 I 2-6-0 I Scale=1:17.7 1.5x3 II 3x4 = 1.5x3 II 3x4 = 1.5x3 II 1 2 3 4 5 0 ° ° e .- 8> 7 3x5—3x4= 3x4= 011- 9-8-4 I 0-1 9-6-12 LOADING (psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.17 Vert(LL) -0.01 7 >999 480 MT20 220/195 TCDL 10.0 Lumber DOL 1.00 BC 0.16 Vert(TL) -0.06 6-7 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.17 Horz(TL) 0.01 6 n/a n/a BCDL 5.0 Code IBC2012/TP12007 Matrix-R Weight:47 lb FT=0%F,50%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 6=420/0-4-0,8=420/0-4-4 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=688/0,3-4=-688/0 BOT CHORD 7-8=0/430,6-7=0/536 WEBS 4-6=-626/0,2-7=0/300,2-8=557/0 NOTES- 1)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. (-To P R°Fe., 87022PE r" (5) ./6111tN 7 <\ �A>. OREy� �N 9Or)BER \\ \-.. A. HER EXPIRES: 06/30/2019 October 12,2018 1 I MIMI WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MI1.7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not ^ a truss system.Before use,the building designer must verify the applicability of design parameters and propedy incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek" is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R55803544 PL18-351_UPPER F02 Floor 12 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 8.130 s Mar 11 2018 MiTek Industries,Inc. Fri Oct 12 12:39:55 2018 Page 1 I D:5eV?tdjYilz0X2xysiFDVpzsmUO-ccFbVxm9cGOxfBG7fyJ7BOPOe2PcgRGCi 1 QEw6yU9Gl 1 0-9-4 1 2-6-0 Scale=1:23.4 1.5x3 I I 4x8 = 1.5x3 II 3x4= 1.5x3 I I 3x5 = 1.5x3 I I 1 2 3 4 5 6 7 7a 9 C] 11 10 9 8 4x4 = 4x8 = 3x8= 3x5= 01118 13-9-4 0-1-8 13-7-12 Plate Offsets(X,Y)— f11:Edge,0-1-81 LOADING (psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.18 Vert(LL) -0.04 9-10 >999 480 MT20 220/195 TCDL 10.0 Lumber DOL 1.00 BC 0.26 Vert(TL) -0.09 8-9 >999 360 BCLL 0.0 Rep Stress Ina YES WB 0.42 Horz(TL) 0.02 8 n/a n/a BCDL 5.0 Code IBC2012/TP12007 Matrix-R Weight:67 lb FT=0%F,50%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 8=600/0-1-8,11=600/Mechanical FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-1028/0,3-4=-1028/0,45=1282/0,5-6=-1282/0 BOT CHORD 10-11=0/323,9-10=0/1326,8-9=0/834 WEBS 6-8=-973/0,6-9=0/523,4-10=-349/0,2-10=0/822,2-11=-680/0 NOTES- 1)Refer to girder(s)for truss to truss connections. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)8. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. �``� D PR OFFS, e�5 0NG'INEF� `5> 2 t. 87022PE /9c cv 7 � , OREGON ti� �y Aj I.9On 8 E \1\'‘Q0 A- HER EXPIRES: 06/30/2019 October 12,2018 t it A WARNING.Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERENCE PAGE MlI.7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MTek®connectors.This design is based only upon parameters shown,and is for an individual building component,note a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R55803545 PL18-351_UPPER F03 Floor 12 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 8.130 s Mar 11 2018 MiTek Industries,Inc. Fri Oct 12 12:39:56 2018 Page 1 I D:S e V?tdj Y i l z0X2 xys i F D V pz s m U O-4 vozj H n n N a Wo H LrJ C g g M k b yZKS I GZvP Lwh AoTYyU 9 G H 2-1-4 2-6-0 Scale=1:25.6 1.5x3 I I 4x6 = 1.5x3 II 3x4 = 1.5x3 II 3x8= 1.5x3 II 1I_' 2 3 4 5 6 7 z.- - 00 0 a 1 ® 10 9e 8� 3x5 = 4x8= 3x8 = 3x5 = 01118 15-1-4 0-1-8 14-11-12I LOADING (psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.18 Vert(LL) -0.06 9-10 >999 480 MT20 220/195 TCDL 10.0 Lumber DOL 1.00 BC 0.30 Vert(TL) -0.10 8-9 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.36 Horz(TL) 0.02 8 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 Matrix-R Weight:71 lb FT=0%F,50%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 8=659/0-1-8,11=659/0-1-12 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-3=-1418/0,3-4=-1418/0,4-5=-1476/0,5-6=-1476/0 BOT CHORD 10-11=0/811,9-10=0/1620,8-9=0/931 WEBS 6-8=-1086/0,6-9=0/636,2-10=0/709,2-11=-995/0 NOTES- 1)Provide mechanical connection(by others)of truss to bearing plate at joint(s)8,11. 2)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. <<#) PROFESS �,5N � GINE�,Q /0 Q 87022PE -9r N -' ° "Cj,OREGON r>,a At/ C' MBER OS A- HEY` EXPIRES: 06/30/2019 October 12,2018 t I WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not �p a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/T1.11 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply 'POLYGON R55803546 PL18-351_UPPER F04 Floor 6 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 8.130 s Mar 11 2018 MiTek Industries,Inc. Fri Oct 12 12:39:57 2018 Page 1 ID:5eV?tdjYilzoX2xysiFDVpzsmUO-Y5MLwdoP8tefuVQVmNLbHpVk9s6GI LU V9LvL?yU9GG P-4-9 2-6-0 I Scale=1:22.6 5x8= 1.5x3 II 1.5x3 II 3x4 = 1.5x3 II 3x5 = 1.5x3 II 1 2 3 4 5 6 7 6 ,6 O m �e e 11 10 9 8 5x5= 4x8= 3x6 = 3x4 =- 01118 01118 13-4-0 I 0-1-8 13-2-8 Plate Offsets(X,Y)— f11:Edge,0-1-81 LOADING (psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.18 Vert(LL) -0.04 9-10 >999 480 MT20 220/195 TCDL 10.0 Lumber DOL 1.00 BC 0.25 Vert(TL) -0.08 8-9 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.43 Horz(TL) 0.02 8 n/a n/a BCDL 5.0 Code IBC2012T P12007 Matrix-R Weight:65 lb FT=0%F,50%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 8=581/0-1-8,11=581/Mechanical FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-899/0,3-4=-899/0,4-5=-1219/0,5-6=-1219/0 BOT CHORD 9-10=0/1230,8-9=0/802 WEBS 6-8=-936/0,6-9=0/486,4-10=-387/0,2-10=0/855,2-11=-670/0 NOTES- 1)Refer to girder(s)for truss to truss connections. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)8. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. �co� AGP 4-,19 SAO 87022PE r N. °F...A.-.67�N y �Aj, OREGON tikN 'AC'i ' BER .,,N‘4 ' A. HER EXPIRES: 06/30/2019 October 12,2018 1 ' A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not ^ a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Infonnation available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R55803547 PL18-351_UPPER F05 FLOOR GIRDER 2 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 8.130 s Mar 11 2018 MiTek Industries,Inc. Fri Oct 12 12:39:57 2018 Page 1 ID:5eV?tdjYilz0X2xysiFDVpzsmUO-Y5MLwdoP8tefuVQVmNLbHpVf0s3YIJVVV9LvL?_yU9GG 1-8-8 I 2-6-0 Scale=1:24.9 3x4 II 4x10 = 1.5x3 II 3x4= 1.5x3 I I 4x8 = 3x4 II 1 12 2 13 3 14 4 15 16 5 17 6 18 19 7 o o o' 0 je 05e oe'' 10 e 9 e 4x6 = 4x10= 4x8= 4x8= I 14-11-8 14-11-8 Plate Offsets(X,Y)— I1:Edge,0-1-81,(8:Edge,0-1-81 LOADING (psf) SPACING- 1-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.51 Vert(LL) -0.09 9-10 >999 480 MT20 220/195 TCDL 10.0 Lumber DOL 1.00 BC 0.42 Vert(TL) -0.14 9-10 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.56 Horz(TL) 0.04 8 n/a n/a BCDL 5.0 Code IBC2012/TP12007 Matrix-R Weight:75 lb FT=0%F,50%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 11=949/0-5-8,8=1072/0-5-8 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=2006/0,3-4=-2006/0,45=2195/0,5-6=-2195/0 BOT CHORD 10-11=0/1061,9-10=0/2359,8-9=0/1522 WEBS 6-8=-1765/0,6-9=0/785,5-9=-278/0,4-10=-411/0,3-10=-332/0,2-10=0/1103,2-11=-1386/0 NOTES- 1)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 2)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)152 lb down at 3-0-0,152 lb down at 13-2-8,117 lb down at 1-3-11,112 lb down at 4-6-1,112 lb down at 6-1-4,112 lb down at 7-8-7,112 lb down at 9-3-10, 112 lb down at 10-10-13,and 112 lb down at 12-6-0,and 118 lb down at 14-1-3 on top chord. The design/selection of such connection device(s)is the responsibility of others. 3)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 , vEp P R Ore. S Uniform Loads(plf) Vert:8-11=-5,1-7=-50 \Gj �NGINEFq /0 Concentrated Loads(lb) /1j Vert:6=-112(F)3=-112(F)12=-117(F)13=-152(F)14=-112(F)15=-112(F)16=-112(F)17=112(F)18=-152(F)19=-118(F) Ltd 87022PE 9r N -11141 (Ne 7 �A). OREGON cy� 4N ��'ns'l'�BER \\\ 1.7O A- HER EXPIRES:06/30/2019 October 12,2018 t t A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not MN. a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mire k" is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R55803548 PL18-351_UPPER F06 FLOOR GIRDER 2 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 8.130 s Mar 11 2018 MiTek Industries,Inc. Fri Oct 12 12:39:59 2018 Page 1 ID:5eV?tdjYilz0X2xysiFDVpzsmUO-UU U5LJpfgVuN8oauuo03MEa30goUmHiocfoS3tyU9GE 1-8-8 2-6-0 Scale=1:24.9 3x4 II 3x5= 1.5x3 II 3x4= 1.5x3 II 3x4= 3x4 II 1 2 3 4 5 6 7 o no ee --' 41111111141411111111114141111114111114111114111111140 Q 10 g 3x6 = 3x6= 3x6= 3x6 = I 14-11-8 14-11-8 Plate Offsets(X,Y)— 11:Edge,0-1-81 LOADING (psf) SPACING- 1-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.13 Vert(LL) -0.03 9-10 >999 480 MT20 220/195 TCDL 10.0 Lumber DOL 1.00 BC 0.20 Vert(TL) -0.06 8-9 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.26 Horz(TL) 0.01 8 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 Matrix-R Weight:75 lb FT=0%F,50%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 11=404/0-5-8,8=404/0-5-8 Max Uplift 11=125(LC 6),8=-125(LC 7) Max Gray 11=486(LC 3),8=486(LC 2) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=938/172,3-4=-938/172,4-5=-997/156,5-6=-997/156,6-7=-351/351 BOT CHORD 10-11=-261/609,9-10=-151/1054,8-9=-233/731 WEBS 6-8=-855/280,6-9=-310/611,4-9=-413/394,4-10=-438/375,2-10=-296/683, 2-11=-700/214 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift at joint(s)except(jt=lb) 11=125,8=125. 3)This truss has been designed for a total drag load of 2000 lb.Lumber DOL=(1.33)Plate grip DOL=(1.33) Connect truss to resist drag loads along bottom chord from 0-0-0 to 14-11-8 for 133.7 plf. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. rr Strongbacks to be attached to walls at their outer ends or restrained by other means. `�4`D PR OFFS ,„5 �GtL NEER s>0 � 87022PE 4-2_ _*-4../ y �A.), OREG N ti� �N 9O F,yBER \\ ""'.- ......e. �O OSA HE��P EXPIRES:06/30/2019 October 12,2018 t I. Ak .... WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev.10/03/1015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not �P a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Miele is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPII Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heiohts,CA 95610 Job Truss Truss Type Qty Ply POLYGON R55803549 PL18-351_UPPER F07 Floor 4 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 8.130 s Mar 11 2018 MiTek Industries,Inc. Fri Oct 12 12:39:59 2018 Page 1 I D:5eV?td)Yi I z0X2xysi FD Vpzsm U O-U U U5 LJpfg Vu N 8oauuo03 M Ea3lgq Wm L6ocfoS3tyU 9GE 0-11-4 I 2.6-0 1 1.5x3 I I 2 3x4 = 3 1.5x3 I I Scale=1:11.1 II 111 II WM II 2 cl 1 and NEM IP AIN AT/ 5 �' 3x4= 3x4 = 1- 3-8-4 I 1 3-6-12 LOADING (psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.17 Vert(LL) 0.00 5 **** 480 MT20 220/195 TCDL 10.0 Lumber DOL 1.00 BC 0.07 Vert(TL) -0.02 4-5 >999 360 BCLL 0.0 Rep Stress Incl. YES WB 0.04 Horz(TL) 0.00 4 n/a n/a BCDL 5.0 Code IBC2012/TP12007 Matrix-P Weight:20 lb FT=0%F,50%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 3-8-4 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=157/0-4-0,5=157/Mechanical FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Refer to girder(s)for truss to truss connections. 2)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. `-, IAG P Esq s% 87022PE 4. 91-- (5.16C4411 7 �Aj, OREGON (yam �N "P ',1,/BER \\�P\O A- HER EXPIRES: 06/30/2019 October 12,2018 A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not �p a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing M Ire IC is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R55803550 PL18-351_UPPER F08 Floor 12 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 8.130 s Mar 11 2018 MiTek Industries,Inc. Fri Oct 12 12:40:01 2018 Page 1 I D:5eV?tdjYilz0X2xysiFD VpzsmUO-Rtcsm?rvC685N6kG?DQXRffOjTW9EFT54ztY8lyU9GC I 2-6-0 f 0-11-12 1 1 0-6-12 4.41= 1 1.5x3 II 2 3x4= 3 3x4 II 4 Scale=1:11.1 J • / . . e 7 S 5 1.5x3 II 3x4 = ti 37-47_4 3r80-1 I 46-8 0- 8-4 1 ctrl 0-1-8 Plate Offsets(X,Y)— f4:0-1-8,Edgel LOADING (psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.21 Vert(LL) 0.00 7 >999 480 MT20 220/195 TCDL 10.0 Lumber DOL 1.00 BC 0.06 Vert(TL) -0.01 6-7 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.05 Horz(TL) 0.00 6 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 Matrix-P Weight:28 lb FT=0%F,50%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 4-6-8 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 7=128/Mechanical,6=385/0-6-0 Max Gray 7=152(LC 3),6=385(LC 1) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4)CAUTION,Do not erect truss backwards. 5)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)125 lb down at 4-5-12 on top chord. The design/selection of such connection device(s)is the responsibility of others. 6)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 Uniform Loads(plf) ��ckEo P R()Fess Vert:5-7=-8,1-4=-80 Concentrated Loads(lb) 5 GINE n / Vert:4=-125(F) Vim '� FR q2 87022PE 9r c N -37 �-0j, OREGON cf.) <v� 'P N.,1,/BER \\�QO A. HER EXPIRES:06/30/2019 October 12,2018 I , AWARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MiTekSr connectors.This design is based only upon parameters shown,and is for an individual building component,not * a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R55803551 PL18-351_UPPER F09 Floor 15 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 8.130 s Mar 11 2018 MiTek Industries,Inc. Fri Oct 12 12:40:01 2018 Page 1 D:5 a V?tdjYi I zoX2 xys i F D V pz s m U O-Rtcsm?rvC 685 N 6 kG?D QX RffOoT W Q E F 054ztY8IyU 9 G C 2-6-0 0-5-12 I 0-6-12 4x41 1 1.5x3 II 2 4x4= 3 3x4 II q Scale=1:11.1 • o 7 S 51.5x3 II 3x4= 4f64 3-1-4 3 2-lr I 4-0-8 3-1-4 1- 0-8-4 0-1-a Plate Offsets(X,Y)— [4:0-1-8,Edge] LOADING (psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.20 Vert(LL) 0.00 7 >999 480 MT20 220/195 TCDL 10.0 Lumber DOL 1.00 BC 0.04 Vert(TL) -0.01 6-7 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.06 Horz(TL) 0.00 6 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 Matrix-P Weight:27 lb FT=0%F,50%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 4-0-8 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 7=102/Mechanical,6=368/0-6-0 Max Gray 7=129(LC 3),6=368(LC 1) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4)CAUTION,Do not erect truss backwards. 5)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)125 lb down at 3-11-12 on top chord. The design/selection of such connection device(s)is the responsibility of others. 6)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 Uniform Loads Opes Concentrated Vert:Loads(lb) 80 ���,NGP 4- s1/0 Vert:4=-125(F) �C? I, -57 'r 870 2PE <' N (N1 y CNAI>, OREGON cf,:) �N sMBERON�Q�O A- HECk EXPIRES: 06/30/2019 October 12,2018 mos A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not �p a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 _ _.. Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R55803552 PL18-351_UPPER F10 Floor 6 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 8.130 s Mar 11 2018 MiTek Industries,Inc. Fri Oct 12 12:40:02 2018 Page 1 I D:5e V?tdjYilz0X2xysi FD Vpzsm U O-v3AEzLsYyQGy?G I TZwxm_sCaztsXzik EJcd6gCyU9G8 0-5-4 2-6-0 1 1.5x3 I I 2 4x4= 3 1.5x3 I Scale=1:11.2 9 5 • 4x4 = 3x4 = -1- 3-2-4 I -1- 3-0-12 Plate Offsets(X,Y)-- 15:Edge,0-1-81 LOADING (psf) SPACING- 1-7-3 CSI. DEFL. in (loc) l/defl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.17 Vert(LL) 0.00 5 **** 480 MT20 220/195 TCDL 10.0 Lumber DOL 1.00 BC 0.05 Vert(TL) -0.01 4-5 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.05 Horz(TL) 0.00 4 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 Matrix-P Weight:18 lb FT=0%F,50%E LUMBER- BRACING- TOP CHORD 2x4 DF No.l&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 3-2-4 oc purlins, BOT CHORD 2x4 DF No.l&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=135/0-4-0,5=135/Mechanical FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Refer to girder(s)for truss to truss connections. 2)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. c_<<- GIN EFS w,.-, 87022PE N �'.0j, OREGON S'yBER ��O A. HER EXPIRES: 06/30/2019 October 12,2018 � I A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MIl-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek` is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R55803553 PL18-351_UPPER F11 Floor 33 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 8.130 s Mar 11 2018 MiTek Industries,Inc. Fri Oct 12 12:40:03 2018 Page 1 I D:5eV?tdjYilz0X2xysiFDVpzsmUO-NFkcBhsAjjOpcQtf7eS?W4kIZH8_t4?NXGMfCeyU9GA 1-11-4 I 2-6-0 1 Scale=1:25.4 1.5x3 II 4x6= 1.5x3 11 3x4 = 1.5x3 II 3x6= 1.5x3 II 1 2 3 4 5 6 7 a le 0 o e i117 1 10 e 9 8k 3x5 = 4x8= 3x8= 3x5 = 0.1118 14-11-4 1 0-1-8 14-9-12 LOADING (psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.18 Vert(LL) -0.06 9-10 >999 480 MT20 220/195 TCDL 10.0 Lumber DOL 1.00 BC 0.29 Vert(TL) -0.10 8-9 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.37 Horz(TL) 0.02 8 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 Matrix-R Weight:71 lb FT=0%F,50%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 8=651/0-1-8,11=651/0-1-12 FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-1369/0,3-4=1369/0,4-5=-1452/0,5-6=-1452/0 BOT CHORD 10-11=0/748,9-10=0/1583,8-9=0/919 WEBS 6-8=-1072/0,6-9=0/622,2-10=0/725,2-11=-945/0 NOTES- 1)Provide mechanical connection(by others)of truss to bearing plate at joint(s)8,11. 2)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. `<-_ PR0Fe0 u.,-„N-• 0NG,I NEER '/O"449 `t 87022PE r co -11144'.-1 '" y �Aj, OREGON (yam 4� "P 11,1 8ER \1�Q�0 A. HEN; EXPIRES:06/30/2019 October 12,2018 I r A WARNING-Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. Design valid far use only with MiTekiS connectors.This design is based only upon parameters shown,and is for an individual building component,not �R a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek" is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R55803554 PL18-351_UPPER F12 Floor 24 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 8.130 s Mar 11 2018 MiTek Industries,Inc. Fri Oct 12 12:40:04 2018 Page 1 ID:5eV?tdjYilz0X2xysiFDVpzsmUO-rRH_OOtoU1WgEZSrgLzE3HHwRh1NtRYNXmw6D14yU9G9 I 0-10-0 I I 2-6-0 I Scale=1:19.2 1.5x3 II 3x4= 1.5x3 II 3x4= 1.5x3 II 1 4x4= 2 3 4 5 6 \_ ofX o e 0 10X 9 8 Zr. 4x5= 3x5 = L� 1.5x3 II 354 = F- _ .. 11-4-0 I 11-4-0 Plate Offsets(X,Y)— f1:Edge,0-1-8) LOADING (psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.18 Vert(LL) -0.02 8 >999 480 MT20 220/195 TCDL 10.0 Lumber DOL 1.00 BC 0.19 Vert(TL) -0.07 7-8 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.30 Horz(TL) 0.01 7 n/a n/a BCDL 5.0 Code IBC2012/TP12007 Matrix-R Weight:56 lb FT=0%F,50%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 10=493/0-4-0,7=493/0-1-8 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 1-10=501/0,1-2=-309/0,2-3=-309/0,3-4=-927/0,4-5=-927/0 BOT CHORD 8-9=0/795,7-8=0/656 WEBS 5-7=-766/0,5-8=0/315,3-9=-567/0,1-9=0/584 NOTES- 1)Provide mechanical connection(by others)of truss to bearing plate at joint(s)7. 2)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 90 aS�� G PE - `r/ IP f4t -9 870 2PE r N tN 7 �'Oj, OREGON cid t/./N 'AOnSMBER \'' A. HER EXPIRES: 06/30/2019 October 12,2018 4 4 A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MI1.7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not mit a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek" is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Suite 109 Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R55803555 PL18-351_UPPER F13 FLOOR GIRDER 3 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 8.130 s Mar 11 2018 MiTek Industries,Inc. Fri Oct 12 12:40:04 2018 Page 1 ID:5eV?tdjYilzoX2xysiFDVpzsmUO-rRH_OOtoU1 WgEZSrgLzE3HHwehRfRP9Xmw6D14yU9G9 I 1-2-12 I 1-10-0 I I 1-8-8 Scale=1:24.8 3x4 II 6x12 = 3x4 I I 3x4= 1.5x3 II 3x4 = 1.5x3 II 4x8 = 3x4 II 1 2 3 4 5 6 7 8 9 e O O zzlzO > 13 e 12 11 5x8 = 6x16= 3x5= 4x10 = 4x6= I 14-11-4 14-11-4 Plate Offsets(X,Y)— [1:Edae,0-1-81,110:Edge,0-1-81,114:Edge,0-1-81 LOADING (psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.16 Vert(LL) -0.08 12 >999 480 MT20 220/195 TCDL 10.0 Lumber DOL 1.00 BC 0.46 Vert(TL) -0.13 12-13 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.89 Horz(TL) 0.04 10 n/a n/a BCDL 5.0 Code IBC2012/TP12007 Matrix-R Weight:80 lb FT=0%F,50%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 14=1285/0-5-8,10=832/0-5-8 FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-2457/0,3-4=-2458/0,4-5=-2473/0,5-6=-2473/0,6-7=-1673/0,7-8=1673/0 BOT CHORD 13-14=0/1086,12-13=0/2559,11-12=0/2168,10-11=0/960 WEBS 8-10=-1222/0,8-11=0/920,6-11=-638/0,6-12=0/393,3-13=-967/0,2-13=0/1745,2-14=-1646/0 NOTES- , 1)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 2)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)825 lb down at 3-6-0 on top chord. The design/selection of such connection device(s)is the responsibility of others. 3)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 Uniform Loads(plf) Opp Concentrated Vert:3—825(F)1 9 80 NS���NG'P EFS `ri0 .C? -9 870 2PE r' -y N / N tv �Aj, OREGON el, 41 �Or, BER �'�_P.O A- HES EXPIRES: 06/30/2019 October 12,2018 I I MOM WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERENCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. 1111111 Design valid for use only with MiTekrE connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing - M iTe Ke is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 1 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R55803556 PL18-351_UPPER F14 FLOOR GIRDER 3 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 8.130 s Mar 11 2018 MiTek Industries,Inc. Fri Oct 12 12:40:05 2018 Page 1 I D:5eV?tdjYilz0X2xysiFDVpzsmUO-JerNbMuQFLeXsj 12E3VTbVg2C4pGAyVg?armHXyU9G8 I 1-8-4 I 2-6-0 Scale=1:24.8 3x4 II 4x8 = 1.5x3 II 3x4 = 1.5x3 II 4x8 = 3x4 II 1 12 2 13 14 3 15 4 16 5 17 6 18 7 "---t— ® _ o e 0 0 o a , 10 e 9 e 4x6 = 4x10= 4x8= 4x6 = I 14-11-4 14-11-4 Plate Offsets(X,Y)— f1:Edge,0-1-81,f8:Edae,0-1-81 LOADING (psf) SPACING- 1-0-0 CSI. DEFL. in (loc) I/deft Lid PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.37 Vert(LL) -0.07 9-10 >999 480 MT20 220/195 TCDL 10.0 Lumber DOL 1.00 BC 0.37 Vert(TL) -0.12 9-10 >999 360 BCLL 0.0 Rep Stress!nor NO WB 0.50 Horz(TL) 0.03 8 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 Matrix-R Weight:74 lb FT=0%F,50%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 11=873/0-5-8,8=833/0-5-8 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-1758/0,3-4=-1758/0,4-5=-1867/0,5-6=-1867/0 SOT CHORD 10-11=0/921,9-10=0/2041,8-9=0/1245 WEBS 6-8=-1444/0,6-9=0/726,4-10=-331/0,3-10=-308/0,2-10=0/977,2-11=-1209/0 NOTES- 1)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 2)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)129 lb down at 3-11-8,129 lb down at 13-3-0,100 lb down at 0-8-9,95 lb down at 2-3-12,89 lb down at 5-6-2,89 lb down at 7-1-5,89 lb down at 8-8-8,and 89 lb down at 10-3-11,and 89 lb down at 11-10-14 on top chord. The design/selection of such connection device(s)is the responsibility of others. 3)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 ``�Ep PR OFF Uniform Loads(plf) is Vert:8-11=-5,1-7=-50 \Co lC.NGLNEF� /. Concentrated Loads(Ib) S :1-- Concentrated 6=89(B)4=-89(B)12=-100(B)13=-95(B)14=-129(F)15=-89(B)16=-89(B)17=-89(B)18=-129(F) �� 87a22PE - N y �Aj, OREGON (yamN<v� �On 8ER \\ \--1 A. Heck EXPIRES:06/30/2019 October 12,2018 I I ma_ A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev.10/03/2015 BEFORE USE. . Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek" is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R55803557 PL18-351_UPPER F15 Floor 3 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 8.130 s Mar 11 2018 MiTek Industries,Inc. Fri Oct 12 12:40:05 2018 Page 1 ID:5eV?tdjYilzOX2xysiFDVpzsmUO-JerNbMuQFLeXsj 12E3VTbVg5C4sbA1 eg?armHXyU9G8 1-5-12 2-6-0 Scale=1:17.1 1.5x3 II 3x4 = 1.5x3 II 3x4 = 1.5x3 II 1 2 3 4 5 e - . 0 e e e 8 7 3x5 = 3x4= 3x4 = Ot1lb 9-4-4 I 0-1 9-2-12 LOADING (psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.17 Vert(LL) -0.01 7 >999 480 MT20 220/195 TCDL 10.0 Lumber DOL 1.00 BC 0.15 Vert(TL) -0.07 6-7 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.17 Horz(TL) 0.01 6 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 Matrix-R Weight:46 lb FT=0%F,50%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 6=406/0-4-0,8=406/0-4-4 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-639/0,3-4=-639/0 BOT CHORD 7-8=0/356,6-7=0/511 WEBS 4-6=-597/0,2-7=0/330,2-8=-504/0 NOTES- 1)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. � 15- PR0A.p ( otNE4\' 87022P vt' ��4jC OR GON r1� tOv� M OBER 1 OS A. HER` �P EXPIRES: 06/30/2019 October 12,2018 • 1 ..- WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERENCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MR-ek®connectors.This design is based only upon parameters shown,and is for an individual building component,not '- a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Wel( is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R55803558 PL18-351_UPPER F16 FLOOR 10 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 8.130 s Mar 11 2018 MiTek Industries,Inc. Fri Oct 12 12:40:06 2018 Page 1 ID:5eV?tdjYilz0X2zysiFDVpzsmUO-ngPlpiv20emNTtcEomOi8iMGoUAgvRmgEEbJpzyU9G7 1-11-8 I 2-6-0 Scale=1:25.4 1.5x3 II 4x6 = 1.5x3 II 3x4= 1.5x3 II 3x6 = 1.5x3 II 1 2 3 4 5 6 7 0 _ 2 05 0 10 ® 1 9 8k 3x5 = 4x8 = 3x8= 3x5 = I 14-11-8 I 14-11-8 LOADING (psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.18 Vert(LL) -0.06 9-10 >999 480 MT20 220/195 TCDL 10.0 Lumber DOL 1.00 BC 0.29 Vert(TL) -0.10 8-9 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.37 Horz(TL) 0.02 8 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 Matrix-R Weight:71 lb FT=0%F,50%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 8=652/0-1-8,11=652/0-1-12 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-1376/0,3-4=-1376/0,4-5=-1455/0,5-6=-1455/0 BOT CHORD 10-11=0/756,9-10=0/1588,8-9=0/920 WEBS 6-8=-1074/0,6-9=0/624,2-10=0/723,2-11=-951/0 NOTES- 1)Provide mechanical connection(by others)of truss to bearing plate at joint(s)8,11. 2)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. ri:c NG'PEFq `S>97022PE r uz */14.9cv y �4j, OREGON (15) 4H 'QOn waER \\ prO A- HER EXPIRES: 06/30/2019 October 12,2018 t i MEM WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not al a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek` is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Symbols Numbering System A General Safety Notes PLATE LOCATION AND ORIENTATION 13/4' Center plate on joint unless x,y 6-4-8 dimensions shown int ft-in-sixteenths Failure to Follow Could Cause Property offsets are indicated. I I (Drawings not to scale) Damage or Personal Injury Ira= Dimensions are in ft-in-sixteenths. 11.46„, Apply plates to both sides of truss and fully embed teeth. 1 2 3 1. Additional stability bracing for truss system,e.g. TOP CHORDS diagonal or X-bracing,is always required. See BCSI. Q.ti16 2. Truss bracing must be designed by an engineer.For wide truss spacing,individual lateral braces themselves p rtffA mayrequirebracing,oralternativeTorI• • _ O .. abracingshouldbeconsidered.1-� 0 d 3. Never exceed the design loading shown and never 0L\kl CJ stack materials on inadequately braced trusses. H °XI p 4. Provide copies of this truss design to the building For 4 x 2 orientation,locate -8 c6-7 c5-6 F- designer,erection supervisor,property owner and plates 0- ' �'from outside BOTTOM CHORDS all other interested parties. edge of truss. 8 7 6 5 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each This symbol indicates the JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE joint and embed fully.Knots and wane at joint required direction of slots in AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO locations are regulated by ANSI/TPI 1. connector plates. THE LEFT. 7. Design assumes trusses will be suitably protected from * CHORDS AND WEBS ARE IDENTIFIED BY END JOINT the environment in accord with ANSIITPI 1. Plate location details available in MiTek 20/20 NUMBERS/LETTERS. software or upon request. 8. Unless otherwise noted,moisture content of lumber shall not exceed 19%at time of fabrication. PLATE SIZE PRODUCT CODE APPROVALS 9. Unless expressly noted,this design is not applicable for use with fire retardant,preservative treated,or green lumber. ICC-ES Reports: The first dimension is the plate 10.Camber is a non-structural consideration and is the 4 x 4 width measured perpendicular ESR-1311,ESR-1352,ESR1988 responsibility of truss fabricator.General practice is to to slots.Second dimension is ER-3907,ESR-2362,ESR-1397,ESR-3282 camber for dead load deflection. the length parallel to slots. 11.Plate type,size,orientation and location dimensions indicated are minimum plating requirements. LATERAL BRACING LOCATION 12.Lumber used shall be of the species and size,and in all respects,equal to or better than that "! Indicated by symbol shown and/or Trusses are designed for wind loads in the plane of the specified.by text in the bracing section of the truss Unless otherwise shown. 13.Top chords must be sheathed or purlins provided at output. Use T or I bracing spacing indicated on design. if indicated. Lumber design values are in accordance with ANSI/TPI 1 14.Bottom chords require lateral bracing at 10 ft.spacing, section 6.3 These truss designs rely on lumber values BEARING or less,if no ceiling is installed,unless otherwise noted. established by others. 15.Connections not shown are the responsibility of others. II Indicates location where bearings (supports)occur. Icons vary but © 16.D o not cut or alter truss member or plate without prior ■I=0 reaction section indicates joint 2012 MiTek®All Rights Reserved pproval of an engineer. number where bearings occur. 17.Install and load vertically unless indicated otherwise. Min size shown is for crushing only. il 10.7-7.110 18.Use of reen or treated lumber may y pose unacceptable environmental,health or performance risks.Consult with Industry Standards: project engineer before use. M ANSI/TP11: National Design Specification for Metal 19.Review all portions of this design(front,back,words Plate Connected Wood Truss Construction. and pictures)before use.Reviewing pictures alone DSB-89: Design Standard for Bracing. snot sufficient. BCSI: Building Component Safety Information, riiiTek® 20.Design assumes manufacture in accordance with Guide to Good Practice for Handling, ANSUTPI 1 Quality Criteria. Installing&Bracing of Metal Plate Connected Wood Trusses. MiTek Engineering Reference Sheet:MII-7473 rev. 10/03/2015