Permit (38) CITY OF TIGARD71 ELECTRICAL PERMIT 2 ." , COMMUNITY DEVELOPMENT Permit#: ELC2019-00060 Date Issued: 02/05/2019 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 1S134ACO2649 Jurisdiction: Tigard Site address: 11070 SW COTTONWOOD LN Project: HALSTEAD Subdivision: ENGLEWOOD NO.3 Lot: 215 Project Description: Panel replacement with(20)branch circuits. Contractor: OWNER Owner: HALSTEAD,JOHN &CAROL JOHN&CAROL HALSTEAD 11070 SW COTTONWOOD LN 11070 SW COTTONWOOD LN TIGARD, OR 97223 TIGARD, OR 97223 PHONE: PHONE: FAX: FEES Quantity Description Date Amount 1 ea Services or Feeders-200 02/05/2019 $100.70 Specifics: amps or less 20 crt Branch Circuits w/Purchase 02/05/2019 $148.40 Type of Use: SF Service or Feeder Class of Work: ALT 1 ea 12%State Surcharge- 02/05/2019 $29.89 Electrical Type of Const: Occupancy Grp: Total $278.99 Required Items and Reports(Conditions) This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is sus. ded for •re the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Cen r. Those r •s re set fo h in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a co. _ - . - •r direct questions to OUNC by calling 503. 32.191 or 1.800.332. • l 'Al Issued By: . ��i� r_�_ Permittee Signature: %I OWNER INSTALLATION ONLY The installation is being made on property I own which is not intended for sale,lease or rent. OWNER'S SIGNATURE Date: CONTRACTOR INSTALLATION ONLY SIGNATURE OF SUPR.ELEC' Date: LICENSE NO. Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Electrical Permit Application Folz 01:1:1(I I SI. 0\1.1 City of Tigard _ eceived III _ a} te/B : r1�� 1. ill 13125 SW Hall Blvd.,Tigard,OR 97223 v 'Plan Review Phone: 503.718.2439 Date/B : Related Permit#: r r'– 1. 1' :1 c,^K D Email: TigardBuildingPermits@Tigard-or.gov ) 1 Ready Date/By: ® See Page 2 for I Inspection Line: 503.639.4175 Internet: www. or.gaV CO4 Notified/Method: BMA Supplemental Information TYPE OF WORKr , i_ (GP 4� PLAN REVIEW � .�, El New construction ElAddition alteration/r 11;Btit�� g le`i,3 @`�Id.3�``� Please check all that apply(submit 2 sets of plans w/items checked): L,'0,1!..1\-‘-'-1: ❑Service or feeder 400 amps or more 0 Building over three stories. El Demolition ' her: where the available fault current 0 Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings. d 2-famil y dwellingless to ground,or exceeds 14,000 0 Commercial-use agricultural ❑Commercial/industrial ❑Accessory building amps for all other installations. buildings. ❑Multi-family 0 Master builder 0 Other: 0 Fire pump. 0 Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION 0 Emergency system. larger separately derived n ^ ❑Addition of new motor load of system. j I Job#: Job site address: U V (,r/ f4-11,1_Ode d L 4,fil( 100HP or more. ❑"A","E","1-2","1-3", City/State/ZIP: �� q ®� ❑Six or more residential units. occupancy. J0 Health-care facilities. 0 Recreational vehicle parks. Suite/bldg./apt.#: Project name: /1.44 j vied_pL 0 Hazardous locations. 0 Supply voltage for more than ❑Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: FEE SCHEDULE Description I Qty. I Each I Total I * New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. 1,000 sq.ft.or less 168.54 4 Tax map/parcel#: Ea.add'I 500 sq.ft.or portion 33.92 1 DESCRIPTION OF WORK Limited energy,residential 75.00 2 y / (with above sq.ft.) / 'f �I4 ✓ IAA/1 6,31) 6, ,...v._•pitj G L-7,4%1v• Limited energy,multi-family 1 residential(with above sq.ft.) 75.00 2 Renewable Energy 0 See Page 2 .26-ROPERTY OWNER ❑"TENANT Services or feeders installation,alteration,and/or relocation Name: J k --,:i),-N" 1,444(�d v\ 200 amps or less r 100.70 02,„70 2 Address: i)Q 1)< --'6,,, 'd�1�t civck / v 201 amps to 400 amps 133.56 2 City/State/ZIP: e 401 amps to 600 amps 200.34 2 —te r QAC( d< 601 amps to 1,000 amps 301.04 2 Phone:c5(13) 46 3 Over 1,000 amps or volts 552.26 2 - Temporary services or feeders installation,alteration,and/or Email: relocation Owner installation:This•. stallatio is 'ein m..• on property that I own which is not 200 amps or less 59.36 1 intended for sale,lea • r�l , •r exc.: :e,/or O: .447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: /i� Date: .I'l- / 401 amps to 599 amps 168.54 2 0 • PLICANT ❑ CONTACT PERSON Branch circuits–new,alteration,or extension,per panel A.Fee for branch circuits with Business name: above service or feeder fee, / 7.42 ,yl � 2 • each branch circuit Contact name: B.Fee for branch circuits without service or feeder fee,first Address: branch circuit 56.18 2 City/State/ZIP: Each add'l branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:( ) Each manufactured or modular dwelling,service and/or feeder Email: 67.84 2 Reconnect only 67.84 2 CONTRACTOR Pump or irrigation circle 67.84 2 Business name: a�q n) 1)L(n Id) t� 4,4 e Sign or outline lighting 67.84 2 �/Lh" W'/' V(i Signal circuit(s)or limited-energy Address: i J 0(7d 3& t(�T " L , panel,alteration,or extension. 0 See Page 2 2 NG City/State/ZIP: T j dc,9 a Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr Phone:(tj 4,f3 'eft -t 62or, Investigation(1 hr min) 90.00/hr Email: Industrial plant(1 hr min) 78.18/hr Inspections for which no fee is 90.00/hr CCB Lic.: d 4/(7 4 Electrical Lic.: Suprv.Lic.: specifically listed('V hr min) ELECTRICAL PERMIT FEES Suprv.Electrician signature,required: Subtotal: I Lo Print name: Date: 0 Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): ?--G]•M Authorized si atu e: C TOTAL PERMIT FEE: --- ��<�This permit application expires if a permit is not obtained within 180 Print name: Date: �.'� �q days after it has been accepted as complete. `� * Number of inspections allowed per permit. I:\BuildingTermit LC_PermitApp_ELR ERE.doc Rev 10/26/2017 440-4615T(11/05/COM/WEB Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: SOUL E RESIDENT' k WORK`ONLY: FEE v t * Fee for all residential systems combined: $75.00 Description I QtY• I Each I To�I I 3' Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 50.01 to 100 kva 552.26 2 ❑ Garage Door Opener* >100 kva(fee in accordance with OAR 918-309-0040) 552.26 2 ❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva-no additional charge 0.0 3 Each additional inspection over allowable in any of the above: ❑ Other: Each additional inspection is 66.25/hr 1 charged at an hourly(1 hr min) Inspections for which no fee is 90.00/hr specifically listed(1/2 hr min) 74" COMMERCIALWO y. �` Subtotal(Enter on Page 1). Fee for each commercial system: $75.00 * Number of inspections allowed per permit. (SEE OAR 918-309-0000) Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations I:\Building\Permits\ELC_PerniitApp_ELR_ERE.doc Rev 10/26/2017