PFI2019-00003 CITY OF TIGARD■.114 PUBLIC FACILITIES IMPROVEMENT PERMIT COMMUNITY DEVELOPMENT Permit#: PF12019-00003 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 01/09/2019 T f(-.' .f7 g Parcel: SEG2387 Jurisdiction: Tigard Site address: Subdivision: Lot: Project: PGE Project Description: SEG 2387 12279 12214 12321 /2320 12384 12385. Bore/trench to install new underground primary cable. PGE Job M2495673. Owner: FEES Description Date Amount PFI Permit Fee 01/09/2019 $300.00 PHONE: Contractor: POTELCO INC 14103 STEWART RD SUMNER,WA 98390 PHONE: 253-863-0484 FAX: Applicant: PHIL MERRIMAN 10800 SW AVERY STREET TUALATIN, OR 97062 PHONE: 503-612-2935 Total $300.00 Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact information of responsible parties before beginning work. Permittee/Applicant ��E AeftLc4uoIJ larmAti Issued By: f1JLL/4 Special Conditions(See Attached) Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY Conditions for PFI2019-00003 Type: Condition Name: Status: Severity: PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice Applicant must comply with all applicable provisions of federal and state law, the Tigard Municipal Code, and the terms of any agreement with the City of Tigard regarding work to be done pursuant to this permit. PFI_Utilities 02 -WORK SITE AREA Applied Notice The work area and approach roads shall be maintained in a clean condition,free from obstructions and hazards. The spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up and suspension of work to accomplish clean-up. PFI_Utilities 03 -WORK SITE EROSION CONTROL Applied Notice Prior to starting work,effective and approved erosion control devices must be installed and maintained meeting the Clean Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to accomplish effective erosion control. PFI_Utilities 04 -WORK SITE REPAIRS Applied Notice Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes, etc. shall be reinstalled or replaced,with like kind of material. Obtain City approval of restoration work. PFI_Utilities 05 -TRAFFIC CONTROL SPECIFICATIONS Applied Notice Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices [MUTCD]for Streets and Highways", U.S. Dept. of Transportation, FHWA, current edition,American Traffic Safety Services Association [ATSSA], and Oregon Temporary Traffic Control Handbook[OTTCH]. PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work area. Traffic control devices,flag persons, etc., shall be in place prior to initiation of construction work and shall be effectively maintained. PFI_Utilities 07 -TRAFFIC CONTROL ROAD CLOSURE Applied Notice Public roadway shall not be closed to traffic, at any time,without obtaining written approval from the City Engineer. The applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and area wide Emergency Services: 503-629-0111 (Tigard Police Dept., Tualatin Fire & Rescue)and to 503-962-8140(Tri-Met) and 503-431-2345 (Tigard School District)and other service providers impacted by such closure. PFI_Utilities 08 -TRAFFIC CONTROL PROPERTY ACCESS Applied Notice Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City approval of any access closures. PFI_Utilities 09-TRAFFIC CONTROL WORK HOURS Applied Notice Work is permitted in daylight between the hours of 7:00 a.m. to 7:00 p.m. Mon-Fri unless otherwise authorized by the City. PFI_Utilities 10-TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m. to 9:00 a.m. unless authorized by the City Engineer. PFI_Utilities 11 -TRAFFIC CONTROL MODIFICATION Applied Notice The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to assure public safety. PFI_Utilities 12 -UTILITY NOTIFICATION Applied Notice Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR 952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987. If you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit holder's expense. PFI_Utilities 13-UTILITY LOCATION CONFLICT Applied Notice Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work (pothole before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work with affected utility agencies. PFI_Utilities 14 -TEMPORARY PATCH Applied Notice A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is liable for hazards or damage resulting from the prosecution of the work. PFI_Utilities 15-REPAIR OF EXISTING FACILITIES Applied Notice Work under this permit shall include repair of existing facilities (roads, ditches, etc.) as may be necessary, as determined by the Inspector, to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit. Corrective work shall be done at the applicant's expense. PFI_Utilities 16-PRECONSTRUCTION MEETING Applied Notice Before initiating any construction activity, the applicant shall coordinate with the City's inspector, <Insert Name> at<Insert Phone#>, to establish a preconstruction meeting. PFI_Utilities 17 -NOTICE TO COMMENCE WORK Applied Notice The applicant shall notify the City's Inspector twenty-four(24) hours prior to commencing work, prior to any staged inspection, and after completing work covered by the permit. PFI_Utilities 18- PERMIT/PLAN ON SITE Applied Notice A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work performance. PFI_Utilities 19-MONUMENT PROTECTION Applied Notice Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's expense. PFI_Utilities 20 -EMERGENCY CONTACTS Applied Notice Provide to the City inspector, in writing, the names and 24 hour emergency telephone number of two (2)persons who have authority to resolve problems,take corrective action and, in general,will be responsible in case of any emergency. The applicant shall notify the City Inspector, in writing, of any/all assignment changes. PFI_Utilities 21 -OTHER Applied Notice RECEIVED City of Tigard JAN 0 7 2019 PUBLIC WORKS —ENGINEERING CITY OF TGA;"' ) Public FacilityImprovement PFI Permit TIGARD TYPE OF WORK DESCRIPTION OF WORK(in the right-of-way) [TYPE 1—Franchise Utility Work Check one: VUtilities ❑ Sidewalk/driveway approach ❑ Streetimprovements performed by NWN, PGE Detailed description: Bore/trench to install new underground and/or utility agency. primary cable ❑ TYPE 2—Sidewalk/Driveway/Sewer Work performed for the purpose of: PGE Job M2495673 • Sidewalk installation or repair. Property address/location(s): 9890 SW KIMBERLY DR • Driveway approach installation and/or repair 2381 f 22'19/Z2J TIGARD, OR, 97224 • Sanitary sewer lateral installation 2:621/ 232V/ 23 '23 ec and/or main line tap ❑ TYPE 3—Full scale Development Applicant: PGE [Submitted by Amy Sweany] Work performed with Land use Address: 10800 SW Avery Street approval which includes any of City/state: Tualatin, OR Zip: 97062 the following: Phone: 503-612-2935 Email: preregcoord@pgn.corn • Subdivisions or Partitions Contact name: Phil Merriman Phone: 503-963-6943 • Street widening • Mainline installation for Sanitary Contractor: Potelco, Inc. sewer, Storm sewer, Tigard water 76668 and/or Tigard Water Service Area CCB#: Expiration: Address: 38884 Pacific Highway SUBMIT COMPLETED APPLICATION TO: City/state: Hubbard, OR Zip: 97032 City of Tigard Planning/Engineering Phone: 253-389-4936 Email: jaborden@potelco.net 13125 SW Hall Blvd. Contact name: Tony Borden Phone: 971-275-6954 Tigard,OR 97223 Applications for"minor work in right-of-way" Engineer: Ph i I Merriman only may be emailed to: rowpermits@tigard-or.gov Address: 10800 SW Avery Street Tualatin, OR 97062 FOR STAFF I. SI: O\I.1 City/state: Zip: Phone: 503-963-6943 Email: preregcoord@pgn.com Case No.:Fffi--0(9*-OOo03 Contact name: Application submittal fee(.007%of Engineer's Estimate) $ Estimated value of work is required(if over$5,000):$ Additional fees: $ 34) (within the public right-of-way) Application accepted: By: Pcl - Date: ' (i tcl Is work related to a LAND-USE DECISION. ❑ Yes VNo If so,please specify (MLP,SDR,SUB, etc.) case#: Application reviewed: By: &wry Date: 1-7 / ? Is work related to a BUILDING PERMIT? ❑ Yes "No Applicant notified: g iIf so,please specify(BUILDING PERMIT)case#: By: S C Date: �[q I:\ENG\PermitApplications\pfi_application Rev.10/16/2017 City ofTigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 1 of4 APPLICANTS NOTE: Person specified as"Applicant"shall be designated"Permittee"and shall provide financial assurance for work,if required by the city pursuant to TMC 15.041.140. * With the exception of a utility operating pursuant to a valid franchise with the City of Tigard,when the owner and the applicant are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner(s)must sign this application in the space provided or submit a written authorization with this application. Franchised Utilities are not required to obtain the owner's signature on the application BY SIGNING BELOW,THE APPLICANT(S) SHALL CERTIFY THAT: • The above request does not violate any recorded deed restrictions that may be attached to or imposed upon the subject property. • If the application is granted,the applicant will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. • All of the above statements and the statements in any plot plan,attachments,and exhibits transmitted herewith,are true;and the applicants so acknowledge that any permit issued,based on this application,may be revoked if it is found that any such statements are false. • The applicant has read the entire contents of the application,including the policies and criteria,and understands the requirements for approving or denying the application. Vinh D Nguyen, Digitally n,pE ned by Vinh D PE Date:2019.01.03 16:49:34 -08'00' Applicant/Authorized Agent's signature Print name Date SIGNATURES of each owner of the subject property, if required. Owner's signature Print name Date Owner's signature Print name Date Owner's signature Print name Date fii'JYfWWdr9ulFtl W6t-: .Sq�,....r..:'. .. .,. .....; ',., -....... �.:.3 ._.}:+&A,,.asa+:dA3fs�'s:3:ii):i&.<s&SY,?xnri4��nsiA. •- ••'""W�lSfi`ffiEM dAut.._.. _ '�X114®tE...,.,+..,.: r......a... PUBLIC FACILITY IMPROVEMENT PERMIT City ofTigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 2 of DEVELOPMENT ENGINEERING FEES FOR STAFF ISE ONL Public Facility Improvement(PFI)Permit: DETAILED SUBMITTAL APPLICATION FEE REQUIREMENTS Part 1: Required submittal fee$300.00 (minimum) FRANCHISE UTILITY AND SIDEWALK/ DRIVEWAY AND UTILITY PERMIT FEE CONNECTIONS,ETC. Part 2: All non-water system improvements (work in the right of way) Engineer's estimate X 5%(less$300.00 minimum submittal fee) Sketch Engineer's estimate X 2%Plan Review (including information below) ❑ Dimensions WATER SYSTEM FEE ❑ Street Name Part 3: All public water system improvements ❑ Site Address Engineer's estimate X 12% FULL SCALE DEVELOPMENT PFI Permit Fee Exemptions: (Subdivisions/Partitions and Street Improvements) There will be no permit fee charged,or assurance required for the following types of work: Design Plans • Sidewalk repair(less than 20 lineal feet) (6 sets,24x36 or 22x34) • Relocate or replace mailbox ❑ Cover—Site,Vicinity,Abbreviation,Legend • Ditch cleaning that does not involve regrading. ❑ General Notes(City,Water,Sewer,etc.) • Weep hole repair ❑ Street(Plan,Profile) • Curb repair or replacement(less than 20 lineal feet) ❑ Water,Storm and Sanitary(Plan Profile) • Lawn sprinkler system installation or repair ❑ Water Quality Facilities • Street tree pruning or planting ❑ Grading • Planter strip landscape maintenance ❑ Landscaping/Tree Plan • Test wells ❑ Composite Utility Plan(Electrical,Phone,Gas, Storm,Sanitary,Water,Signage,Street Lights,etc) ❑ Details Note: A cash/bond assurance may be ❑ Traffic Sight Distance required per TMC 15.04.140. ❑ Signing and Striping (customer deposit) ❑ Street Light Plan and Photometric ❑ Engineers seal/signature ❑ Sheet label(project land use name,revision and plan log block,dates and sheet numbers.) Additional Submittals (per Land Use conditions) ❑ Traffic Report ❑ Storm water Drainage Calculations ❑ Geotechnical Report ❑ Preliminary Access Report(Sight Distance) ❑ Proposed Plat ❑ Pathway Design(if applicable) ❑ Water Department Approval ❑ Engineer's Construction Estimate PUBLIC FACILITY IMPROVEMENT PERMIT City ofTigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 3 of SAMPLE SKETCH: f) \,\- .. y s i Edge of Pavement le--- Ditch ."(?\Streetlight , __•—•—.—.—.—._ .—r—.— + Rain Dram 'Po..--.01."41., I i • _ a ...7/' ' T--Frivi'orecrsiwe r ri=r__ 1 NI I 1 Fr . Existing House 1 I -t: 1 Existing 1 T-• • Driveway • i- il 0i I CI ■ ' • O - 1 .%-i3I 4' a i L I ;I I 1 o. Existing Shop I EA1\b1/4N1 Powerpole I I I f, 1 95' 1 I I --------17ropertyt e----------- I I Fire Hydrant(F1-1) I II I I I Scale: 'I"=30' I I I I I I I I I I I. I I MINIMUM SKETCH REQUIREMENTS(Put"N/A"if Not Applicable): North arrow Property lines &dimension Slope of property Street &street name(s) Existing building, structures Utility&street light poles Proposed work Existing curb or edge Trees Existing S/W or of pavement Existing utility locations D/W apron (sewer,water,storm) PUBLIC FACILITY IMPROVEMENT PERMIT City ofTigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 4 of IL 15., .35 A T6 LEGEND .... ... NOTE,REPLACED ON NM 4•61.I./69.96.4615101,1.611.1416...1 E.1., L. wL11104. DURHAM NORTH I 114249567W 2.4, imMuae111000 (3)EASON MT-NID PARE-NAL 44 cABLE-S2AL C 50 25011 .,1.• ..-. ..- ,......., ... 204 ,i IMA2S4 tRA V ISI=E I= .914.11.••472.fin r 99.1.1.19777 1.5 1.5 ,1., '' 21 1- 1990 .t4o*'.4•07:=:::44f9 956 14.35, ....., ,.9 ... .. -- 25 EOUF.13. ,,,,4 ..'•v ' C 5121111 .9-1• 30. 10125 , ..,.. , •..1, T Mr 9,19411.1.91.4 4900C.0.17 VAII IOW lb• ,... 10315 FOIE., ,----IDLE CLASS(31.3,4 113112.31 ICI. .•. • , 01 ELBow PIT.NT°CABLE.NAL /AC112151 'a IC) loms ,,,,,,,,,,,ii, -- ---•- , 137 ELBOW NIT.!STD CABLE•NAL I------401,HEISM 15571200 1 144:...:...............),‘1:115121 v24N6„., 76..A-s 4.11 v i Al 59 44 A 44441MAIMODM..... 1071.11, MI5 ELBOW NT--.KT()CABLE-WAL ELBOW MT-JKTO CABLE-S2AL . ..r. . 142 CD F257 uG TAP .4 P.CONDUIT UNIT 142 CO 425T US TAP Rd.N. I 30 II1i i 241 PVC C.DUIT UNIT o..., LANDSCARNO NOTES 1NOTE OPEN WILL BE INSTALLED IN A-"" 0 P.n. PRE-LANDSCAPING DURHAM NORTH E11624.6111, it _. 7014610 ,,AAD 2. .1-11 WL2 P0-704.WL3 P0-7677.WL4 PO7675 A WEI PD-7174.OUR VEGETATION COVERING XFMR WL5 PO7675 REMOVE A STACK LANDSCAPE ROCK W.-I 'o4T 1:4 4 Roo '17-.' WL7 PD-I413:REMOVE A STACK LANDSCAPE ERICK Vs WLII 10-1534.REMOVE PICKET FENCE ;I: •'2.1 • 10.1 NOTE RE PUGH)ON /996 11.4 2.9.1 POST-LANDSCAPING: DURHAM NORTH E 411,,A. .,. --vr. a I. WL 2 67,14.WL2 P0-7674 A PAU 114515.NATIVE FAL ,, 1.4956611 NO- .,..,,, wi.7 11,1111 SKI PO7427:BARK DUST Is, :;,, ... 4 In 5 PO7675.1.370E4 LANDSCAPE ROCK A (21)ELSON 101/..KTD GRLE-NAL g 4 P676714 WLS PO-7674.BARK OUST 4 VEGETATE TO CUSTOMER REQUEST „\, 7011 ...,490 7171 riT1 111•14 1,5 ID TIT4 10,MA A21 ELBOW WT.JKTO GJILE•PO,"'"'"'"DCA8LE-'2' 121 ELBOW NT-.1470 CABLE-RAL C2 2.12C i ,1000 155.0 W47 P041213.-RESTORE LANDSCAPE ERICK WM,P0-1332:RESTORE PICKET FENCE INL13 P0-46013NATIVE FAL A VEGETATE TO CUS TONER REOUEs 7 3•.4.7411 T ."."4".'''' "''' 2-.46T A1154111 '.. • • .. NOTE:IRA...SOW/ER.110ED. .4,1751 ELBOW Ka-MID CAKE-WAL RE-uEvEL TRANSFORMER 7001 1 W/I 2414 ., 4955 157. 15.0 1.4 MI' 0 2 A T5 1115 PRIM i HP GAS MAN-STANO43Y REQUIRED ?Cr . CALL 24 HRS IN ADVANCE SO3,20-2415 VE,61.14 DIAGRAN , ,11 1,218 IMEW 501 1.11.1111 , 15744 4447 11,1. .:. SU36554-VAULT CONC.6642156N At OD UV-604 15225 ..„7,-,, rf: WS , ':5' 3311 6,, SUB./-CONC.NOWSUP SIT UD 56-436-46.501506 1 OW .. .95 : .. ,. (4)ELBOW ICR,JKID CAKE-WAL .4,, ES' 'c', .55 613 11091. ,,,,,. .. 104MA D-767 '. r.,?NA r-Ctf-D,7Y-5-• 13)ELBOW KIT-JKTO CABLE-62AL .4.1 1 Ma 255 .: 1-/ Is ,. . , . 13)ELBOW KR-JKTO CABLE-62AL wss WI. ' I I. 15975 Id W6111,1111 LD ELSOW KIT-JKTO CABLE-WM. '26.'-'. PO-757s-- 1616_______„t,7,1 I 10 20151 ...e)ELBOW KI7-JKTO CAI.-NAL „0,,, '_ __''__ir __ _ a PDS.• -. C 1511111 A II II ir 4i' ,.,-: `,, .,,,s . • .'-:; wx ....: ' 4 i A 2 AL TO PO-76M'. 0 ELBOW 107-.1KTO CPA. '5" 1 A 50 , ,1 01. tam 15005 VELlOW KII-JCTO CM. ilem MT m 'C.IOWA ii:i 972, IPA ' .... 4, 199. •\ 15915 15615 A 5 70.7175 7.2.,,A,2 'VIE-LEM VAT,ILTD CAKE-NAL 1/1417 ,......,...,.,. VT-67M i ,5425 0'7 t (2)ELROD SIT-JEW/GINE-S2AL , .„„ CS A It 1015 Y ,,,.,, NOTE:NORM.OPEN.SEM OPF CAELE CONDE PROD PDS04 1705 I42 GAO RAN m.ND 2-INPvC CONDUIT WIT 143 CJO FICOT U0 TAP NOTES 1 MuST MANTON 5 FT.HORM.TAL SEPARATION FROL1 WATER MAINS AND I FT.VERTICAL SEP.AllON BELOW 15.0 .30 ,.., .. 6(1.:) .'... . 'T I 41 3•150 1.T 160 2-P1VC...SUIT UMT ...1 I SI 3.114. coLm Z.IAAINTAN 1 FT.SEPARATION FROM CITY OF TIGARD I WM... 1 50 30•61 :.A• .„,,,...'../.' CATCH BAS/NS. 3.USE 45,10.BENDS,F.OPEN BOTTOM VAULTS. 6 IN . ..., MC... FIELD CUT 8.0 ABOVE GRADE TO PROVIDE SLACK FOR Amass 750 61. .4.4.1141.1-90.44-, SWITCHING.MAI TENSIONS ASSUME SO•BEND,. ... .35'. .I 1 11413/ Irma: 4.REPLACE GROUND RODS IF EXCESS.CORR.ION IS s ww 421 ELBOW NT-JKTO C.LE.s2AL DISCOVERED DURING CONSTRUCTION. ,2)ELBOw NT-SK213 GALE-s2AL 5.GROUND ABANDONED CABLE PER LCZ203.5-7, .4., 6..ECK COORDINATION OF STREET UGHT FUSING. AIN ,,,,„ wres '.... 4445 5.... / ...•15 .. f.. ,,,,,,,, .„ 5 2117112 'pii,:„5,......42..,_. -py,6 10055 ... C 7511114 ATI 42 ':5'.'-• 1 55 28311 ......; '''..:21:.....7 .....' C2 1-14E1 •.,-, I ais-4 r. B 10/IIII . -- -3 1.55 1. THIN SAFETY FIRST/ ANY DEVIATION FROM THIS DESIGN MOST 8E APPROVED BY E1:15 AGE PROTECT MA NA/YR .T3 Ill MOO TITS SIO 411.11011: 811 FM..11-7 At 4 If f.IA MI W.)-01•04 10 ''1'1;1•4'''IFO:111:1.:74E1:;:::7:71;erirt:21::7„117:„'17 7, 11 "9:!1117:1'Arl'I.g;1::41TIff'4‘117:IT:fr.17.7=9.1. 9.31.11 0.1.1.TO 1774747,09 NW comISINWINw246644. AS-MIALT WAIF,. .733 :=0,40.0 CAS SOPMEM REv IL 6 I4,7.;7,:Es I.9 ti/DESNL '''t.in 6 9012 I'10.01 r10000096.1.--4.',..?3 #(.4%, =7s:CABR,LE:LEDPUCEISENT-Dow..NORTH I+-2165iiF.T. ...PGE/;.;,;'s',..1004111ERLY OR,TiGARD.OR.47224 ,N.. '16C:S'E'CIMENTS OF UG PRIMARY ;1;41-NMN1./r1..1.1Q,C211411 I 3 .6.6..7:66.1-414:1112.1.1 671404-'3'52111/6DI BoOMER .1,..,..,,...s Awn 510,12-NAN r,761,.co..119691.16 6194/113 1-LINE DIAGRAM ir -- *- -�_-_ , _11111117 ---'-'711'--"*'..,—4''''' . .. . , ,,-, WORK AR Y,,..`+ .n..mM�. r.,, r ____----- C21 •w.W -11C • C21-110 'o ..Y,mi • .a, x ..s Y `min .. / ... c u YY. ` .w__c AA6ecCZ AI :!, 9. •11{, ,� u,r ....c_..„, .a„s '„, ••Mra.,r.l;R „ .^ ...- 11131.0 ..''...:1;,, 4. et i t -.0 c < ... . , teY.-..” C2 1-1dA C21-148 .11660114 <,. .n,m , ANY DEVLIRONFROMTMSDESIGN MUST BE APPROVED BY THE PGE PROhCT MANAGFF ,760 6•6116anatoe i?N„Y. / SAFETY Annon a",o .��•.., ,1. I FIRST . .,7,1.I L �,w031/60,113166.116.1111.1...,., 11.1.1fOR TO PrBSRB5R6ewwBRwwB D. T C M„ •r frLATION Z NEsc v�al.,rions conwerTEo nn farc...., Zf-------- :..:„, n..... ; , SL EM1C IQVEM PV+�,rYT+>aN��1lY0E5/fi69f Wh;T:.,w. „A12011 T;�•3011 r;D;000, rD0007136 yN 2:976,7 J1.1113AMETED CABLE REPIAGE.IM-DUNAN NORTM-:.653,7 z,,cr-\ p� RNC GRYSU.M,ERINElD r Yl.]. PGE,'19‘907W.MMER.DR,T,WRD.O0..T27. _ • 00 SEGMENTS Of MO PRIMARY 0 65 130 260 feet T,.".2 '''' 3 N WA6NIIDTDNf G21,1C,C211.BwOl�r Imo' 20i1 ▪`�VII NERRIMN 9T,JO.36MI13g100MER ..=';':::..a,•urr mo.n,:c,.csu.r.MI,m RaAvm LEGEND PD-6609--\ 10#2 EPR in 2"HDPE CONDUIT 30#2 EPR in 4"HDPE CONDUIT 1 NOTFc 1. MUST MAINTAIN S FT.HORIZONTAL SEPARATION FROM WATER MAINS AND 1 FT.VERTICAL SEPARATION BELOW 2. MAINTAIN 1 FT.SEPARATION FROM CITY OF TIGARD CATCH BASINS 3 USE 45'/90'BENDS,FOR OPEN BOTTOM vAULTS. FIELD CUT BEND ABOVE GRADE TO PROVIDE SLACK FOR SMITCHING.(PULL TEirE CE ASSl10E 90'BEND)). A. REPLACE GROUND RODS IF EXCESSIVE CORROSIpJ I$ �1 DISCOVERED DURING CONSTRUCTION. "�\ S. CNE. ABANDONED CABLE PER LC22T FuSI VT-6610 6. CHECK COORDINATION OF STREET LIGHT FUSING TRANSFORMER LOADING PL-3015-,l` VT-6759 PRASE SRI EDI Inv NEWT D// A 50 20537 M No A 10 WIN 31 NO A SO 20851 Al NO PD-7678 A !o 201204 Si NO PD-8213 A 20 its 20 NO w A a 41115 20 No PD-7674 IP-5 A a 4540Sa NO A 717 156 20 NO ABC 112 3011 71 NO , PRIMARY CABLE&CONDUIT TABLE CONDUIT MUMMY rw11E3 ASWNr INFORMATION 1 LOCATION WI OTT worm LENGTH PULL PULL CA{IE LENGTH LENGTH \ Lin) OE0KM ACTUAL 1110 091GN ACTUAL PMMA-CnnLPMb \\ PD-8532- N211 10 IN INN 1101 (ON) NN 0TYIN (D) IDI NOTES VILA 1407011 2 1 5A a 53 RUM E205 IP4lit �. j P073171vro{ 2 1 m, a a 12 ALw 317 MU 100377 2 1 13 s A .2 ALM NI P0-7675 VT731 PW535 2 1 420 a 73 1u EM AS I 111735107878 2 s !N s 45 RUEM 531 PL-1590 PO/OS PO/VI{ 2 1 310 57 47 IRUEM 315 NO04 107213 2 1 NO M 54 RAL EM MO PD-7677—11 ". IP-2 Pours Pour 2 1 >b, NI a RUEPA ON KOMI 81118 2 1 10 17 15 RUEPA 115 I VT-236 r12o6 MU 2 1 5 2 2 112 AL EPA 30 1 VEMIO POO 4 1 Mo 520 817 cu MEM 1115 I IP-1-fPD-7676 Toa LPN 21111 2M6 I 701 51 t 015 I I VT-14 Jp TRENCH-FOOT TABLE CONCUR U.CATION SME Ori LUKE.LENGTH Lin) 0510N ACTIN. MOM To MI ON WL1 VT-14 0L6 PD-7614 WU r1 30 E11511NG VAULT (Nr a EX5TNG OPEN 1.3 .DTSTS 55 - . Y _ N t -o BOTTOM VALAI WI VT2.1 in ��{ 1616 1-Nae c�T -Yqs I] 111 - 7l0 PO for ono !/ N. 0. PORTE ` /'�- • ..f.—1r. .— A▪ •072071 LA .61 ICRETS MO OLI PPM. II LL 5 m oeL R 2 I i IRIP. PI ▪ KM] UN .P 130 i • LJr.... P.M VPUMPTG,0 {o e 6 .12135 VTAS! Watt 3 PO-7675 ' ->TO PD-8213 VTYTO P.M. W WL7 PD-7676 WL/PD-82131 —- Hew S5NG OPEN LT/.... EXISTING OPEN . TOM VAULT 0 g1'h '..,.E4.,t/,},.r`00110H VAULT '% r 2110 "'ne „:,...-=..:,-- r S.O 11 - { ... i.-->TO 1,20_.,0 .'.13 PDo PDi-6 PAD IN r roam TO v1-236<- >TO 0-I5 :0 PD-1614E L>- TO PC-8532 I .m a�.a I ExSGNG OPEN n..o - ,;STING OPEN nw,� 010 PD-8532 ® a( BOTTOM VAULT ON VAULT - �" •° " ,f'\ .-e . rt ®rI !—�r"... a Ne..a =nso -.._. 20.200 ,i L_ - ..c -fr ...✓-�u�..... 1.01:1::.s 011.1•00—1na7 L 140- \ ...N NY N- 1 IW TY jUIDG 1 RTtli / ,o,�6j; w14 VTz�6 � j T 0`'"z.-a. O 6 TO VT-236‹-j 'y`TO PO-8213 ^�By 2Rq�- Apo 1Y 0 -JI TO PL-1390 i7'ca+T—�5�� ,6j5 LIG. K t l.. OI•...A..M ��� .MMI we K.Y.n.H. WL4 PU-76 78 1.1„,......"..N...._ WL11 VT-6/59 <�� n...m E>nSTING OPEN EXISTING VAULT CALL.. BEFORE YOU OHG 1riPOT10M VAULTA7-IEN7ION �� ,rte. OREGON LAW REQUIRES MI /OILOW RUES ADOPTED BV THE OREGON UTILITY NOTIFICATION CENTER. CO 10� ` T110.SE RULES ARE SETFORTNNOAF 163-0111-01110 M1616 THE WAIFBYUGH CA LING E°RE ON I/N COPES OF �N' P0� 504.0�siiAtroa THE RDFS BY CALLING THE OREGON U7NTY PPP 513331& N011FICA 710N CENTER AOMIM57RATIOH®(6012)7./957) I �L�pL~'—a,� I O REQUEST UTILITY LOCA IL S CALL THE OREGON .......� p ii' 57OM k. UTILITY NOTIFICATION CENTER.811 AT LEAST 1 BUSINESS DAYS PRIOR TO EXCAVATION �'°5 Wore 7W�O ,�> ,.' PGE CONSTRUCTION DRAWING o q SDRWENG REVIEW I AS-BUILT BY DESIGNER: °1s AS-BUILT VERIFICATION&NESC VIOLATIONS CORRECTED TO VT-236 This[locvmenl eccurete y represents FIELD c0nsbuclron FOr9man: DIN: WI PL, WL12 VT-6610 GF: DIN: I+rl � 1/06 OPEN EXISTING VAULT 11.21.11(28/2018 tUALC NTS IAcco'"1070001 IAwv.1000007834 IJ0°ND-112458872 .� �. 1ION VAULT -±:� p _ �.r-s w`'0p' L UNJACKETED CABLE REPLACEMENT-DURHAM NORTH H-2,8SSFT --MIT:. r 1001,1%- _` 01Y1rY...: ` clLtwT bQE: mos .w JNG CT7YSUMMERFIELD 1 34)(22 j. kZ �GE LM.TAw: " `/ 10 S G KIMBERLY DR.UMARYTIGAR.OR.87254 -:, SEGMENTS THINK 10 SEGMENTS Of UG PRIAWIY CCxAVM1 SECT 51 reef NEM aN.ET: L SAFETY SONSET WASHINGTON �" cz+l+c.c2114e 1- ,W, _66p,. ��"" FIRST! LIE CENTER DE.IONIY: AILK Mum. lu 00 ,6 -1 4P501AY t257rrAVE. PHIL MERRIMAN 971.804.35791 HEIDI BOOMER N EL'' ' ' '0R.71N 0 00911.04)GENERAL ELECTRIC 00.ALL NIGHTS RESERVES Page 84 2011 Edition Co N Stationary Lane Closure with Flagging Diagram 320 J Diagram 320 covers total closure of one lane of a two-lane, two-way N roadway. See the detail inset for the layout if using a single flagger to control both directions of traffic on low volume roads (less than 400 ADT)with good sight distance as discussed below. 1. Use truck-mounted flashing warning lights on work and protection vehicles. See Section 4.3—Lights and Lighted Signs for exceptions. 2. For added visibility, a truck-mounted arrow board or PCMS in caution mode may be used. 3. Flaggers at each approach are required if any of the following conditions exist: a. Night Operations. b. Work space is over 200 feet in length. c. Sight distance is less than 750 feet from each approach through the lane closure. d. Traffic volumes are greater than 400 ADT. 4. The length between the Flagger Ahead signs shall not exceed one mile. Use Diagram 340— Lane Closure with Pilot Car if exceeding one mile. 5. Cones should be used to outline the work space when curves or other roadway alignments prevent clear direction for the motorists to pass the work space safely. 6. Cones along the work space are recommended when posted speeds are 45 mph or greater, when working under heavy traffic or when travel lanes are narrower than 11 feet. 7. Extended queue signing (see Diagram 5-4) should be used when traffic queues extend beyond the initial advance warning sign. 8. When flagging near an intersection, the "Flagger Ahead" (CW23-2) sign should be visible to traffic entering from any side road. Additional advance warning and Flagger Ahead symbol signs may be placed on the side road(s). 9. Sign set-up and flagger placement shown may be used for intermittent full road closures of 20 minutes or less. 10. The"ONE LANE ROAD AHEAD" (W20-4) sign is optional and should be considered on high volume or high speed roads, or when extended queues are expected. Chapter 5 December 2011 2011 Edition Page 85 N r- Stationary Lane Closure with Flagging Diagram 320 N Y \ v El Ib � ., -_ O o rn m v) CZ : W ir;a1 -* I t LL0 i i— / AbihkQ W' t loo •• me • U O v• ° . ICCuj::41AF— l 1 Q� 8 � I _ E ai- cn r moi, I• - I' • • 0 • ,,,- aE v� ; rn3o 4,.• _ ,,„.. a) o 0< 1 < �m i V I w o Ce 4I4,1:t CO mWo "CT) �� a. CD Sign Spacing and Buffer Lengths(feet) t `� z c Posted Spacing Between Signs Buffer 0 g Lu p Speed A B C Space zo¢Q O 20 50 \ 25 100 100 100 75 30 100 35 125 0Y Q0Q 40 350 350 350 150 O O W 45 180 `ria / 50 500 500 500 210 / 55 250 December 2011 Chapter 5 Page 118 2011 Edition Lane Closure at Intersection with Flagging Diagram 620 Diagram 620 covers work within an intersection when normal traffic control must be interrupted. Work vehicles may or may not be in the work space. 1. During flagging, traffic signals shall be turned off. Contact the road jurisdiction for approval and assistance (see Chapter 3). 2. For multi-lane facilities, traffic approaching the intersection shall be reduced to a single lane on each approach. See Chapter 3 for information on flagging through intersections. 3. There should be one flagger for each approach. One flagger may control two adjacent approaches if sight distance, low volumes on side roads, and flagger position allows for safe operation and clear direction to motorists. For low traffic volume intersections (fewer than 400 entering vehicles per day), one flagger may be used. 4. The "ONE LANE ROAD AHEAD" (W20-4) sign is optional and should be considered on high volume or high speed roads, or when extended queues may be expected. Sign Spacing and Buffer Lengths(feet) 0 Posted Spacing Between Signs Buffer a� Speed A B C Space 20 50 25 100 100 100 75 30 100 35 125 40 350 350 350 150 45_ 180 50 500 500 500 210 55 250 Chapter 5 December 2011 2011 Edition Page 119 Lane Closure at Intersection with Flagging Diagram 620 ROAD WORK AHEAD ONE (Optional) ROAD LANE A t AHEAD B BE PREPARED - TO STOP 1 •'�. B A A cin ► yi • E LARE ROAD • 100 A.Max SPE.,� ROAD • TO STOP WORK . AHEAD A B B C Buffer / •• \ �c 7) • -► Fey � �' • 0—* 100 B.Max H I C B B A I • WORK I ROAD aE A •a P 100 R Max • LANE ROAD • AHEAD Donal • A B BE PREPARED TO STOP B cyal ONE LANE 1 1 ROADAHEAD ROAD WORK AHEAD December 2011 Chapter 5