Loading...
Report (17) /t4 s 77-vi Page 1 C:\Users\NWUD\Desktop\NWUD OFFICE\(STONEBRIDGE HOMES)\JOB 1453\1453-275-0P12-BEAMS\1453-275-0P12-BE1 LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2012.1 06/12/13 14:56:53 WARNING *** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY JUL. 2 3 2013 *** WOOD-E DESIGN 2012.1 EXPIRES ON 3/31/2014. LP WILL MAKE AVAILABLE TO CITY( TeGAR® ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN ^�C (a THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES, DV (J DI1/'�yq�t INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS. V �(Jr1J COMPANY: STONEBRIDGE HOMES JOB ID: 1453-275-OP12-BEAM 1 STATE: OR CODE: IBC PRODUCT: 2-PLY 1-3/4" X 11-7/8" LP LVL 2950Fb-2.0E DESIGN CRITERIA FOR ROOF BEAM (UNFACTORED LOADS) LIVE DEAD SPAN (L) SPAN (R) ALLOWABLE DEFLECTION (PSF) (PSF) CARRIED CARRIED SLOPE LOADING LIVE TOTAL 30 15 22.000' 0.000' 0.00 TOP L/240 L/180 SPAN CARRIED IS NOT CONTINUOUS. ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD ACTUAL 2661 6549 2087 0.081 0.125 ALLOWABLE 10500 20246 8035 0.508 0.678 STRESS INDICES 0.253 0.323 0.260 L/1502 L/978 LOAD CASE 1 1 1 1 1 **** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS. **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . NOTES CONNECTION *** DESIGN ASSUMES COMPONENTS CARRIED ARE APPLIED TO TOP EDGE OF BEAM, SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY. ***ATTACH THE TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT 12" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR HALF FROM EACH FACE. NAILS MAY BE COMMON OR BOX NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131" 16d SINKERS (3-1/4") MAY BE USED, BUT HALF MUST BE DRIVEN FROM EACH FACE. *** COMPRESSION EDGE BRACING REQUIRED AT 24" O.C. OR LESS. *** THIS LVL BEAM HAS BEEN DESIGNED TO SUPPORT A 300 LBS CONCENTRATED LOAD ACTING OVER 2.5 X 2.5 FT (6.25 SQ FT) STRUCTURAL GEOMETRY SPAN 1 10.500' TOTAL SPAN: 10.50 FT LOAD PATTERNS CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 X1 (FT) X2 (FT) +ALL 1 UNIF DEAD ROOF TOP 165.0 PLF 0.000 10.500 +ALL 1 UNIF WEIGHT BEAM 11.9 PLF 0.000 10.500 +1 1 UNIF LIVE ROOF TOP 330.0 PLF 0.000 10.500 r Page 2 1453-275-0P12-BEAM 1.dsn +2 1 UNIF LIVE ROOF TOP 0.0 PLF 0.000 10.500 3 1 UNIF LIVE ROOF TOP 120.0 PLF 0.333 2.833 4 1 UNIF LIVE ROOF TOP 120.0 PLF 7.667 10.166 5 1 UNIF LIVE ROOF TOP 120.0 PLF 4.000 6.500 + INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF. SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF 1 6549 2087 1.00 2 2285 736 0.90 3 2503 994 1.00 4 2503 994 1.00 5 2954 886 1.00 UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS REACTIONS FOR TOTAL LOADS CASE BRG#1 BRG#2 1 2661 2661 2 929 929 3 1183 974 4 974 1183 5 1079 1079 REACTIONS FOR DEAD LOAD CASE BRG#1 BRG#2 1 929 929 2 929 929 3 929 929 4 929 929 5 929 929 REACTIONS FOR LIVE LOAD CASE BRG#1 BRG#2 1 1733 1733 2 0 0 3 255 45 4 45 255 5 150 150 MINIMUM BEARING SIZES (IN) BRG# 1 BRG# 2 4.000 4.000 LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM 1 1 0.081 0.508 L/1502 0.125 0.678 L/978 2 1 0.000 0.508 0.044 0.678 L/2801 0.044 0.065 3 1 0.005 0.508 L/25792 0.048 0.678 L/2532 4 1 0.005 0.508 L/25792 0.048 0.678 L/2532 5 1 0.011 0.508 L/10801 0.055 0.678 L/2224 **** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 **** **** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. **** **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . STRESS INDICES CASE MSI VSI 1 0.323 0.260 Page 3 1453-275-0P12-BEAM 1.dsn 2 0.125 0.102 3 0.124 0.124 4 0.124 0.124 5 0.146 0.110 SLENDERNESS RATIO = 3.39 LIMIT = 10.00 VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR UNCERTAINTIES, PLEASE CONTACT LP. THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS. USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION. Page 1 C:\Users\NWUD\Desktop\NWUD OFFICE\(STONEBRIDGE HOMES)\JOB 1453\1453-275-0P12-BEAMS\1453-275-0P12-BEJ LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2012.2 06/14/13 01:14:08 WARNING *** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY *** WOOD-E DESIGN 2012.2 EXPIRES ON 3/31/2014. LP WILL MAKE AVAILABLE TO ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES, INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS. COMPANY: STONE BRIDGE HOMES NW LLC JOB ID: 1453-275-0P12-BEAM A STATE: OR CODE: IBC PRODUCT: 3-PLY 1-3/4" X 16" LP LVL 2950Fb-2.0E DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS) LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION (PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL 40 15 NO 13.500' 0.000' SIDE L/360 L/240 SPAN CARRIED IS NOT CONTINUOUS. ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD ACTUAL 12843 40711 12516 0.256 0.450 ALLOWABLE 13781 52849 16240 0.490 0.735 STRESS INDICES 0.932 0.770 0.771 L/689 L/392 LOAD CASE 4 4 4 4 4 **** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS. **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . NOTES CONNECTION ***ATTACH TWO PLIES WITH 3 ROWS OF 16d (3-1/2") NAILS AT 12" OC. FROM ONE FACE ONLY. STAGGER ROWS. FLIP BEAM AND ATTACH THE THIRD PLY WITH 3 ROWS OF 16d (3-1/2") NAILS AT 12" OC. TO THE UN-NAILED SIDE OF THE FIRST TWO PLIES. STAGGER ROWS. NAILS MAY BE COMMON OR BOX NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131". 16d SINKERS (3-1/4") MAY BE USED. *** CONCENTRATED LOADS MUST BE EQUALLY DISTRIBUTED TO ALL PLIES. ADDITIONAL FASTENERS MAY BE REQUIRED. *** COMPRESSION EDGE BRACING REQUIRED AT 24" O.C. OR LESS. STRUCTURAL GEOMETRY SPAN 1 15.000' TOTAL SPAN: 15.00 FT LOAD PATTERNS CASE SPAN SHAPE TYPE SOURCE LOADING Wl W2 Xl (FT) X2 (FT) ALL 1 UNIF DEAD ROOF TOP 341.0 PLF 2.500 15.000 +ALL 1 *UNIF DEAD FLOOR SIDE 101.3 PLF 0.000 15.000 ALL 1 UNIF DEAD WALL TOP 100.0 PLF 0.000 15.000 +ALL 1 UNIF WEIGHT BEAM 24.0 PLF 0.000 15.000 ALL 1 CONC DEAD ROOF TOP 1708.0 LBS 2.500 ALL 1 CONC DEAD ROOF TOP 622.0 LBS 2.500 1 1 UNIF LIVE ROOF TOP 511.5 PLF 2.500 15.000 Page 2� 1453-275-OP12-BEAM A.dsn +1 1 *UNIF LIVE FLOOR SIDE 202.5 PLF 0.000 15.000 1 1 CONC LIVE ROOF TOP 2562.0 LBS 2.500 1 1 CONC LIVE ROOF TOP 933.0 LBS 2.500 2 1 UNIF LIVE ROOF TOP 0.0 PLF 2.500 15.000 +2 1 *UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 15.000 2 1 CONC LIVE ROOF TOP 0.0 LBS 2.500 2 1 CONC LIVE ROOF TOP 0.0 LBS 2.500 +3 1 *UNIF LIVE FLOOR SIDE 270.0 PLF 0.000 15.000 4 1 UNIF LIVE ROOF TOP 682.0 PLF 2.500 15.000 4 1 CONC LIVE ROOF TOP 3416.0 LBS 2.500 4 1 CONC LIVE ROOF TOP 1244.0 LBS 2.500 * INDICATES SIDE LOAD. + INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF. SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF 1 40352 12173 1.00 2 17595 5188 0.90 3 24878 7173 1.00 4 40711 12516 1.00 UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS REACTIONS FOR TOTAL LOADS CASE BRG#1 BRG#2 1 12503 10395 2 5407 4564 3 7432 6589 4 12843 10314 REACTIONS FOR DEAD LOAD CASE BRG#1 BRG#2 1 5407 4564 2 5407 4564 3 5407 4564 4 5407 4564 REACTIONS FOR LIVE LOAD CASE BRG#1 BRG#2 1 7095 5831 2 0 0 3 2025 2025 4 7435 5750 MINIMUM BEARING SIZES (IN) BRG# 1 BRG# 2 3.500 3.500 CONCENTRATED LOADS SPAN TYPE W1 (LBS) Xl (FT) MIN BRG (IN) 1 DEAD 1708.0 2.500 3.000 1 DEAD 622.0 2.500 3.000 1 LIVE 3416.0 2.500 3.000 1 LIVE 1244.0 2.500 3.000 LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM 1 1 0.251 0.490 L/702 0.446 0.735 L/396 2 1 0.000 0.490 0.194 0.735 L/909 0.194 0.291 3 1 0.079 0.490 L/2224 0.274 0.735 L/645 # Page 3 1453-275-0P12-BEAM A.dsn 4 1 0.256 0.490 L/689 0.450 0.735 L/392 **** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 **** **** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. **** **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . STRESS INDICES CASE MSI VSI 1 0.764 0.750 2 0.370 0.355 3 0.471 0.442 4 0.770 0.771 SLENDERNESS RATIO = 3.05 LIMIT = 10.00 VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR UNCERTAINTIES, PLEASE CONTACT LP. THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS. USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION. Page 1 C:\Users\NWUD\Desktop\NWUD OFFICE\(STONEBRIDGE HOMES)\JOB 1453\1453-275-OP12-BEAMS\1453-275-0P12-BE7 LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2012.2 06/14/13 01:16:56 WARNING *** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY *** WOOD-E DESIGN 2012.2 EXPIRES ON 3/31/2014. LP WILL MAKE AVAILABLE TO ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES, INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS. COMPANY: STONE BRIDGE HOMES NW LLC JOB ID: 1453-275-OP12-BEAM B STATE: OR CODE: IBC PRODUCT: 2-PLY 1-3/4" X 11-7/8" LP LVL 2950Fb-2.0E DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS) LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION (PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL 40 15 NO 14.000' 18.500' SIDE L/360 L/240 SPAN CARRIED IS NOT CONTINUOUS. ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD ACTUAL 4302 9599 4170 0.108 0.150 ALLOWABLE 9188 20246 8035 0.307 0.460 STRESS INDICES 0.468 0.474 0.519 1/1026 L/736 LOAD CASE 1 1 1 1 1 **** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS. **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . NOTES CONNECTION ***ATTACH THE TWO PLIES WITH 3 ROWS OF 16d (3-1/2") NAILS AT 8" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR HALF FROM EACH FACE. NAILS MAY BE COMMON OR BOX NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131" 16d SINKERS (3-1/4") MAY BE USED, BUT HALF MUST BE DRIVEN FROM EACH FACE. *** COMPRESSION EDGE BRACING REQUIRED AT 24" O.C. OR LESS. STRUCTURAL GEOMETRY SPAN 1 9.500' TOTAL SPAN: 9.50 FT LOAD PATTERNS CASE SPAN SHAPE TYPE SOURCE LOADING WI W2 Xl (FT) X2 (FT) +ALL 1 *UNIF DEAD FLOOR SIDE 243.8 PLF 0.000 9.500 +ALL 1 UNIF WEIGHT BEAM 11.9 PLF 0.000 9.500 +1 1 *UNIF LIVE FLOOR SIDE 650.0 PLF 0.000 9.500 +2 1 *UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 9.500 * INDICATES SIDE LOAD. + INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF. SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF 1 9599 4170 1.00 Page 2 1453-275-OP12-BEAM B.dsn 2 2710 1177 0.90 UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS REACTIONS FOR TOTAL LOADS CASE BRG#1 BRG#2 1 4302 4302 2 1214 1214 REACTIONS FOR DEAD LOAD CASE BRG#1 BRG#2 1 1214 1214 2 1214 1214 REACTIONS FOR LIVE LOAD CASE BRG#1 BRG#2 1 3088 3088 2 0 0 MINIMUM BEARING SIZES (IN) BRG# 1 BRG# 2 3.500 3.500 LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM 1 1 0.108 0.307 L/1026 0.150 0.460 L/736 2 1 0.000 0.307 0.042 0.460 L/2609 0.042 0.064 **** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 **** **** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. **** **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . STRESS INDICES CASE MSI VSI 1 0.474 0.519 2 0.149 0.163 SLENDERNESS RATIO = 3.39 LIMIT = 10.00 VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR UNCERTAINTIES, PLEASE CONTACT LP. THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS. USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION. Page 1 C:\Users\NWUD\Desktop\NWUD OFFICE\(STONEBRIDGE HOMES)\JOB 1453\1453-275-OP12-BEAMS\1453-275-OP12-BEE LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2012.2 06/14/13 01:18:46 WARNING *** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY *** W00D-E DESIGN 2012.2 EXPIRES ON 3/31/2014. LP WILL MAKE AVAILABLE TO ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES, INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS. COMPANY: STONE BRIDGE HOMES NW LLC JOB ID: 1453-275-OP12-BEAM C STATE: OR CODE: IBC PRODUCT: 1-PLY 7" X 11-7/8" LP LVL 2950Fb-2.0E DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS) LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION (PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL 40 15 NO 14.000' 18.500' SIDE L/360 L/240 SPAN CARRIED IS NOT CONTINUOUS. ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD ACTUAL 6423 21553 6289 0.264 0.373 ALLOWABLE 18375 40491 16071 0.457 0.685 STRESS INDICES 0.350 0.532 0.391 L/622 L/441 LOAD CASE 1 1 1 1 1 **** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS. **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . NOTES *** COMPRESSION EDGE BRACING REQUIRED AT EACH END OF COMPONENT. STRUCTURAL GEOMETRY SPAN 1 14.000' TOTAL SPAN: 14.00 FT LOAD PATTERNS CASE SPAN SHAPE TYPE SOURCE LOADING Wl W2 X1 (FT) X2 (FT) +ALL 1 UNIF DEAD FLOOR SIDE 243.8 PLF 0.000 14.000 +ALL 1 UNIF WEIGHT BEAM 23.8 PLF 0.000 14.000 +1 1 UNIF LIVE FLOOR SIDE 650.0 PLF 0.000 14.000 +2 1 UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 14.000 + INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF. SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF 1 21553 6289 1.00 2 6284 1834 0.90 UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS REACTIONS FOR TOTAL LOADS CASE BRG#1 BRG#2 1 6423 6423 • Page 2 1453-275-OP12-BEAM C.dsn 2 1873 1873 REACTIONS FOR DEAD LOAD CASE BRG#1 BRG#2 1 1873 1873 2 1873 1873 REACTIONS FOR LIVE LOAD CASE BRG#1 BRG#2 1 4550 4550 2 0 0 MINIMUM BEARING SIZES (IN) BRG# 1 BRG# 2 3.500 3.500 LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM 1 1 0.264 0.457 L/622 0.373 0.685 L/441 2 1 0.000 0.457 0.109 0.685 L/1511 0.109 0.163 **** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 **** **** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. **** **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . STRESS INDICES CASE MSI VSI 1 0.532 0.391 2 0.172 0.127 SLENDERNESS RATIO = 1.70 LIMIT = 10.00 VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR UNCERTAINTIES, PLEASE CONTACT LP. THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS. USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION. Page f C:\Users\NWUD\Desktop\NWUD OFFICE\(STONEBRIDGE HOMES)\JOB 1453\1453-275-OP12-BEAMS\1453-275-OP12-BE7 LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2012.2 06/14/13 01:21:41 WARNING *** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY *** WOOD-E DESIGN 2012.2 EXPIRES ON 3/31/2014. LP WILL MAKE AVAILABLE TO ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES, INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS. COMPANY: STONE BRIDGE HOMES NW LLC JOB ID: 1453-275-0P12-BEAM D STATE: OR CODE: IBC PRODUCT: 2-PLY 1-3/4" X 11-7/8" LP LVL 2950Fb-2.0E DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS) LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION (PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL 40 15 NO 11.500' 14.000' SIDE L/360 L/240 SPAN CARRIED IS NOT CONTINUOUS. ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD ACTUAL 4992 16752 4888 0.415 0.580 ALLOWABLE 9188 20246 8035 0.457 0.685 STRESS INDICES 0.543 0.827 0.608 L/396 L/283 LOAD CASE 1 1 1 1 1 **** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS. **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . NOTES CONNECTION ***ATTACH THE TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT 6" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR HALF FROM EACH FACE. NAILS MAY BE COMMON OP BOX NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131" 16d SINKERS (3-1/4") MAY BE USED, BUT HALF MUST BE DRIVEN FROM EACH FACE. *** COMPRESSION EDGE BRACING REQUIRED AT 24" O.C. OR LESS. STRUCTURAL GEOMETRY SPAN 1 14.000' TOTAL SPAN: 14.00 FT LOAD PATTERNS CASE SPAN SHAPE TYPE SOURCE LOADING Wl W2 X1 (FT) X2 (FT) +ALL 1 *UNIF DEAD FLOOR SIDE 191.3 PLF 0.000 14.000 +ALL 1 UNIF WEIGHT BEAM 11.9 PLF 0.000 14.000 +1 1 *UNIF LIVE FLOOR SIDE 510.0 PLF 0.000 14.000 +2 1 *UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 14.000 * INDICATES SIDE LOAD. + INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF. SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF 1 16752 4888 1.00 Page 2 1453-275-OP12-BEAM D.dsn 2 4772 1392 0.90 UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS REACTIONS FOR TOTAL LOADS CASE BRG#1 BRG#2 1 4992 4992 2 1422 1422 REACTIONS FOR DEAD LOAD CASE BRG#1 BRG#2 1 1422 1422 2 1422 1422 REACTIONS FOR LIVE LOAD CASE BRG#1 BRG#2 1 3570 3570 2 0 0 MINIMUM BEARING SIZES (IN) BRG# 1 BRG# 2 3.500 3.500 LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM 1 1 0.415 0.457 L/396 0.580 0.685 L/283 2 1 0.000 0.457 0.165 0.685 L/995 0.165 0.248 **** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 **** **** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. **** **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . STRESS INDICES CASE MSI VSI 1 0.827 0.608 2 0.262 0.192 SLENDERNESS RATIO = 3.39 LIMIT = 10.00 VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR UNCERTAINTIES, PLEASE CONTACT LP. THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS. USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION. ' Page'1 C:\Users\NWUD\Desktop\NWUD OFFICE\(STONEBRIDGE HOMES)\JOB 1453\1453-275-0P12-BEAMS\1453-275-0P12-BEI LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2012.2 06/14/13 01:25:48 WARNING *** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY *** WOOD-E DESIGN 2012.2 EXPIRES ON 3/31/2014. LP WILL MAKE AVAILABLE TO ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES, INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS. COMPANY: STONE BRIDGE HOMES NW LLC JOB ID: 1453-275-OP12-BEAM E STATE: OR CODE: IBC PRODUCT: 2-PLY 1-3/4" X 11-7/8" LP LVL 2950Fb-2.0E DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS) LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION (PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL 40 15 NO 0.000' 13.500' SIDE L/360 L/240 SPAN CARRIED IS NOT CONTINUOUS. ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD ACTUAL 3238 10056 3051 0.162 0.299 ALLOWABLE 9188 20246 8035 0.424 0.635 STRESS INDICES 0.352 0.497 0.380 L/940 L/509 LOAD CASE 3 3 3 3 3 **** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS. **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . NOTES CONNECTION ***ATTACH THE TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT 12" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR HALF FROM EACH FACE. NAILS MAY BE COMMON OR BOX NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131" 16d SINKERS (3-1/4") MAY BE USED, BUT HALF MUST BE DRIVEN FROM EACH FACE. *** COMPRESSION EDGE BRACING REQUIRED AT 24" O.C. OR LESS. STRUCTURAL GEOMETRY SPAN 1 13.000' TOTAL SPAN: 13.00 FT LOAD PATTERNS CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 X1 (FT) X2 (FT) +ALL 1 *UNIF DEAD FLOOR SIDE 101.3 PLF 0.000 13.000 ALL 1 UNIF DEAD WALL TOP 100.0 PLF 0.000 13.000 ALL 1 UNIF DEAD ROOF TOP 15.0 PLF 0.000 13.000 +ALL 1 UNIF WEIGHT BEAM 11.9 PLF 0.000 13.000 +1 1 *UNIF LIVE FLOOR SIDE 202.5 PLF 0.000 13.000 1 1 UNIF LIVE ROOF TOP 22.5 PLF 0.000 13.000 +2 1 *UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 13.000 2 1 UNIF LIVE ROOF TOP 0.0 PLF 0.000 13.000 +3 1 *UNIF LIVE FLOOR SIDE 270.0 PLF 0.000 13.000 M . Page 2 1453-275-OP12-BEAM E.dsn 4 1 UNIF LIVE ROOF TOP 30.0 PLF 0.000 13.000 * INDICATES SIDE LOAD. + INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF. SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF 1 9148 2743 1.00 2 4606 1336 0.90 3 10056 3051 1.00 4 5211 1497 1.00 UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS REACTIONS FOR TOTAL LOADS CASE BRG#1 BRG#2 1 2945 2945 2 1483 1483 3 3238 3238 4 1678 1678 REACTIONS FOR DEAD LOAD CASE BRG#1 BRG#2 1 1483 1483 2 1483 1483 3 1483 1483 4 1483 1483 REACTIONS FOR LIVE LOAD CASE BRG#1 BRG#2 1 1463 1463 2 0 0 3 1755 1755 4 195 195 MINIMUM BEARING SIZES (IN) BRG# 1 BRG# 2 3.500 3.500 LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION CASE SPAN ACTUAL ALLOW. LI? ACTUAL ALLOW. L/? INSTANT LONG-TERM 1 1 0.135 0.424 L/1128 0.272 0.635 L/560 2 1 0.000 0.424 0.137 0.635 L/1112 0.137 0.206 3 1 0.162 0.424 L/940 0.299 0.635 L/509 4 1 0.018 0.424 L/8457 0.155 0.635 L/983 **** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 **** **** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. **** **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . STRESS INDICES CASE MSI VSI 1 0.452 0.341 2 0.253 0.185 3 0.497 0.380 4 0.257 0.186 SLENDERNESS RATIO = 3.39 LIMIT = 10.00 VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR • Page 3 1453-275-0P12-BEAM E.dsn UNCERTAINTIES, PLEASE CONTACT LP. THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS. USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION. • Page1 C:\Users\NWUD\Desktop\NWUD OFFICE\(STONEBRIDGE HOMES)\JOB 1453\1453-275-0P12-BEAMS\1453-275-0P12-BE1 LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2012.2 06/14/13 01:30:18 WARNING *** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY *** WOOD-E DESIGN 2012.2 EXPIRES ON 3/31/2014. LP WILL MAKE AVAILABLE TO ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES, INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS. COMPANY: STONE BRIDGE HOMES NW LLC JOB ID: 1453-275-0P12-BEAM F STATE: OR CODE: IBC PRODUCT: 1-PLY 7" X 22" LP LVL 2950Fb-2.OE DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS) LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION (PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL 40 15 NO 0.000' 17.000' SIDE L/360 L/240 SPAN CARRIED IS NOT CONTINUOUS. ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD ACTUAL 13914 100861 13607 0.465 0.797 ALLOWABLE 18375 127300 29773 0.824 1.235 STRESS INDICES 0.757 0.792 0.457 L/636 L/372 LOAD CASE 1 1 1 1 1 **** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS. **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . NOTES *** COMPRESSION EDGE BRACING REQUIRED AT EACH END OF COMPONENT. STRUCTURAL GEOMETRY SPAN 1 25.000' TOTAL SPAN: 25.00 FT LOAD PATTERNS CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 X1 (FT) X2 (FT) +ALL 1 UNIF DEAD FLOOR SIDE 127.5 PLF 0.000 25.000 ALL 1 UNIF DEAD WALL TOP 100.0 PLF 0.000 10.000 +ALL 1 UNIF WEIGHT BEAM 44.1 PLF 0.000 25.000 ALL 1 UNIF DEAD ROOF TOP 15.0 PLF 0.000 10.000 ALL 1 UNIF DEAD FLOOR SIDE 11.5 PLF 10.000 25.000 ALL 1 CONC DEAD ROOF TOP 3041.3 LBS 10.000 ALL 1 CONC DEAD ROOF TOP 1626.7 LBS 8.000 +1 1 UNIF LIVE FLOOR SIDE 255.0 PLF 0.000 25.000 1 1 UNIF LIVE FLOOR SIDE 22.9 PLF 10.000 25.000 1 1 UNIF LIVE ROOF TOP 22.5 PLF 0.000 10.000 1 1 CONC LIVE ROOF TOP 4562.0 LBS 10.000 1 1 CONC LIVE ROOF TOP 2440.0 LBS 8.000 +2 1 UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 25.000 2 1 UNIF LIVE ROOF TOP 0.0 PLF 0.000 10.000 2 1 UNIF LIVE FLOOR SIDE 0.0 PLF 10.000 25.000 2 1 CONC LIVE ROOF TOP 0.0 LBS 10.000 2 1 CONC LIVE ROOF TOP 0.0 LBS 8.000 • Page 2 1453-275-0P12-BEAM F.dsn +3 1 UNIF LIVE FLOOR SIDE 340.0 PLF 0.000 25.000 3 1 UNIF LIVE FLOOR SIDE 30.5 PLF 10.000 25.000 4 1 UNIF LIVE ROOF TOP 30.0 PLF 0.000 10.000 4 1 CONC LIVE ROOF TOP 6082.7 LBS 10.000 4 1 CONC LIVE ROOF TOP 3253.3 LBS 8.000 + INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF. SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF 1 100861 13607 1.00 2 42062 5812 0.90 3 68292 10146 1.00 4 94231 11872 1.00 UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS REACTIONS FOR TOTAL LOADS CASE BRG#1 BRG#2 1 13914 10310 2 6047 4232 3 10434 8803 4 12149 7766 REACTIONS FOR DEAD LOAD CASE BRG#1 BRG#2 1 6047 4232 2 6047 4232 3 6047 4232 4 6047 4232 REACTIONS FOR LIVE LOAD CASE BRG#1 BRG#2 1 7867 6079 2 0 0 3 4387 4571 4 6102 3534 MINIMUM BEARING SIZES (IN) BRG# 1 BRG# 2 3.500 3.500 CONCENTRATED LOADS SPAN TYPE Wl (LBS) Xl (FT) MIN BRG (IN) 1 DEAD 3041.3 10.000 3.000 1 DEAD 1626.7 8.000 3.000 1 LIVE 6082.7 10.000 3.000 1 LIVE 3253.3 8.000 3.000 LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM 1 1 0.465 0.824 L/638 0.797 1.235 L/372 2 1 0.000 0.824 0.332 1.235 L/892 0.332 0.499 3 1 0.243 0.824 L/1220 0.575 1.235 L/516 4 1 0.377 0.824 L/786 0.710 1.235 L/418 **** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 **** **** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. **** **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . STRESS INDICES CASE MSI VSI Page 3 1453-275-0P12-BEAM F.dsn 1 0.792 0.457 2 0.367 0.217 3 0.536 0.341 4 0.740 0.399 SLENDERNESS RATIO = 3.14 LIMIT = 10.00 VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR UNCERTAINTIES, PLEASE CONTACT LP. THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS. USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION. Page 1 C:\Users\NWUD\Desktop\NWUD OFFICE\(STONEBRIDGE HOMES)\JOB 1453\1453-275-OP12-BEAMS\1453-275-OP12-BEJ LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2012.2 06/14/13 11:13:01 WARNING *** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY *** WOOD-E DESIGN 2012.2 EXPIRES ON 3/31/2014. LP WILL MAKE AVAILABLE TO ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES, INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS. COMPANY: STONE BRIDGE HOMES NW LLC JOB ID: 1453-275-OP12-BEAM G STATE: OR CODE: IBC PRODUCT: 3-PLY 1-3/4" X 11-7/8" LP LVL 2950Fb-2.OE DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS) LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION (PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL 40 15 NO 7.500' 6.000' SIDE L/360 L/240 SPAN CARRIED IS NOT CONTINUOUS. ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD ACTUAL 2918 10522 2861 0.194 0.280 ALLOWABLE 13781 30368 12053 0.490 0.735 STRESS INDICES 0.212 0.346 0.237 L/909 L/631 LOAD CASE 1 1 1 1 1 **** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS. **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . NOTES CONNECTION ***ATTACH TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT 8" OC. FROM ONE FACE ONLY. STAGGER ROWS. FLIP BEAM AND ATTACH THE THIRD PLY WITH 2 ROWS OF 16d (3-1/2") NAILS AT 8" OC. TO THE UN-NAILED SIDE OF THE FIRST TWO PLIES. STAGGER ROWS. NAILS MAY BE COMMON OR BOX NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131". 16d SINKERS (3-1/4") MAY BE USED. *** COMPRESSION EDGE BRACING REQUIRED AT 24" O.C. OR LESS. STRUCTURAL GEOMETRY SPAN 1 15.000' TOTAL SPAN: 15.00 FT LOAD PATTERNS CASE SPAN SHAPE TYPE SOURCE LOADING Wl W2 X1 (FT) X2 (FT) +ALL 1 *UNIF DEAD FLOOR SIDE 101.3 PLF 0.000 15.000 +ALL 1 UNIF WEIGHT BEAM 17.8 PLF 0.000 15.000 +1 1 *UNIF LIVE FLOOR SIDE 270.0 PLF 0.000 15.000 +2 1 *UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 15.000 * INDICATES SIDE LOAD. + INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF. SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF . I Page 2 1453-275-OP12-BEAM G.dsn 1 10522 2861 1.00 2 3220 876 0.90 UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS REACTIONS FOR TOTAL LOADS CASE BRG#1 BRG#2 1 2918 2918 2 893 893 REACTIONS FOR DEAD LOAD CASE BRG#1 BRG#2 1 893 893 2 893 893 REACTIONS FOR LIVE LOAD CASE BRG#1 BRG#2 1 2025 2025 2 0 0 MINIMUM BEARING SIZES (IN) BRG# 1 BRG# 2 3.500 3.500 LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION CASE SPAN ACTUAL ALLOW. LI? ACTUAL ALLOW. L/? INSTANT LONG-TERM 1 1 0.194 0.490 L/909 0.280 0.735 L/631 2 1 0.000 0.490 0.086 0.735 L/2061 0.086 0.128 **** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 **** **** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. **** **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . STRESS INDICES CASE MSI VSI 1 0.346 0.237 2 0.118 0.081 SLENDERNESS RATIO = 2.26 LIMIT = 10.00 VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR UNCERTAINTIES, PLEASE CONTACT LP. THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS. USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION. Page 1 C:\Users\NWUD\Desktop\NWUD OFFICE\(STONEBRIDGE HOMES)\JOB 1453\1453-275-OP12-BEAMS\1453-275-0P12-BEI LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2012.2 06/14/13 11:15:34 WARNING *** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY *** WOOD-E DESIGN 2012.2 EXPIRES ON 3/31/2014. LP WILL MAKE AVAILABLE TO ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES, INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS. COMPANY: STONE BRIDGE HOMES NW LLC JOB ID: 1453-275-OP12-BEAM H STATE: OR CODE: IBC PRODUCT: 2-PLY 1-3/4" X 11-7/8" LP LVL 2950Fb-2.0E DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS) LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION (PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL 40 15 NO 9.000' 18.500' SIDE L/360 L/240 SPAN CARRIED IS NOT CONTINUOUS. ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD ACTUAL 1728 1700 1616 0.004 0.006 ALLOWABLE 9188 20246 8035 0.140 0.210 STRESS INDICES 0.188 0.084 0.201 L/12703 L/9096 LOAD CASE 1 1 1 1 1 **** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS. **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . NOTES CONNECTION ***ATTACH THE TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT 6" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR HALF FROM EACH FACE. NAILS MAY BE COMMON OR BOX NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131" 16d SINKERS (3-1/4") MAY BE USED, BUT HALF MUST BE DRIVEN FROM EACH FACE. *** COMPRESSION EDGE BRACING REQUIRED AT EACH END OF COMPONENT. STRUCTURAL GEOMETRY SPAN 1 4.500' TOTAL SPAN: 4.50 FT LOAD PATTERNS CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 X1 (FT) X2 (FT) +ALL 1 *UNIF DEAD FLOOR SIDE 206.3 PLF 0.000 4.500 +ALL 1 UNIF WEIGHT BEAM 11.9 PLF 0.000 4.500 +1 1 *UNIF LIVE FLOOR SIDE 550.0 PLF 0.000 4.500 +2 1 *UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 4.500 * INDICATES SIDE LOAD. + INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF. SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF 1 1700 1616 1.00 Page 2 1453-275-OP12-BEAM H.dsn 2 483 459 0.90 UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS REACTIONS FOR TOTAL LOADS CASE BRG#1 BRG#2 1 1728 1728 2 491 491 REACTIONS FOR DEAD LOAD CASE BRG#1 BRG#2 1 491 491 2 491 491 REACTIONS FOR LIVE LOAD CASE BRG#1 BRG#2 1 1238 1238 2 0 0 MINIMUM BEARING SIZES (IN) BRG# 1 BRG# 2 3.500 3.500 LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM 1 1 0.004 0.140 L/12703 0.006 0.210 L/9096 2 1 0.000 0.140 0.002 0.210 L/32028 0.002 0.002 **** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 **** **** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. **** **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . STRESS INDICES CASE MSI VSI 1 0.084 0.201 2 0.027 0.063 SLENDERNESS RATIO = 3.39 LIMIT = 10.00 VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR UNCERTAINTIES, PLEASE CONTACT LP. THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS. USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION. Page 1 C:\Users\NWUD\Desktop\NWUD OFFICE\(STONEBRIDGE HOMES)\JOB 1453\1453-275-0P12-BEAMS\1453-275-0P12-HDI LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2012.1 06/12/13 14:59:38 WARNING *** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY *** WOOD-E DESIGN 2012.1 EXPIRES ON 3/31/2014. LP WILL MAKE AVAILABLE TO ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES, INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS. COMPANY: STONEBRIDGE HOMES JOB ID: 1453-275-0P12-HDR HI STATE: OR CODE: IBC PRODUCT: 2-PLY 1-3/4" X 9-1/2" LP LVL 2950Fb-2.0E DESIGN CRITERIA FOR ROOF BEAM (UNFACTORED LOADS) LIVE DEAD SPAN (L) SPAN (R) ALLOWABLE DEFLECTION (PSF) (PSF) CARRIED CARRIED SLOPE LOADING LIVE TOTAL 30 15 0.000' 0.000' 0.00 TOP L/240 L/180 SPAN CARRIED IS NOT CONTINUOUS. ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD ACTUAL 5124 7286 4168 0.051 0.077 ALLOWABLE 10500 13282 6428 0.308 0.411 STRESS INDICES 0.488 0.549 0.648 L/1444 L/955 LOAD CASE 1 1 1 1 1 **** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS. **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . NOTES CONNECTION *** DESIGN ASSUMES COMPONENTS CARRIED ARE APPLIED TO TOP EDGE OF BEAM, SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY. ***ATTACH THE TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT 12" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR HALF FROM EACH FACE. NAILS MAY BE COMMON OR BOX NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131" 16d SINKERS (3-1/4") MAY BE USED, BUT HALF MUST BE DRIVEN FROM EACH FACE. *** CONCENTRATED LOADS MUST BE EQUALLY DISTRIBUTED TO ALL PLIES. ADDITIONAL FASTENERS MAY BE REQUIRED. *** COMPRESSION EDGE BRACING REQUIRED AT 24" O.C. OR LESS. *** THIS LVL BEAM HAS BEEN DESIGNED TO SUPPORT A 300 LBS CONCENTRATED LOAD ACTING OVER 2.5 X 2.5 FT (6.25 SQ FT) STRUCTURAL GEOMETRY SPAN 1 6.500' TOTAL SPAN: 6.50 FT LOAD PATTERNS CASE SPAN SHAPE TYPE SOURCE LOADING WI W2 XI (FT) X2 (FT) ALL 1 UNIF DEAD ROOF TOP 337.7 PLF 4.500 6.500 Page 2 1453-275-0P12-HDR Hl.dsn +ALL 1 UNIF WEIGHT BEAM 9.5 PLF 0.000 6.500 ALL 1 CONC DEAD ROOF TOP 1626.7 LBS 4.500 1 1 UNIF LIVE ROOF TOP 675.3 PLF 4.500 6.500 1 1 CONC LIVE ROOF TOP 3253.3 LBS 4.500 2 1 UNIF LIVE ROOF TOP 0.0 PLF 4.500 6.500 2 1 CONC LIVE ROOF TOP 0.0 LBS 4.500 3 1 UNIF LIVE ROOF TOP 120.0 PLF 0.333 2.833 4 1 UNIF LIVE ROOF TOP 120.0 PLF 3.667 6.166 5 1 UNIF LIVE ROOF TOP 120.0 PLF 3.300 5.800 + INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF. SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF 1 7286 4168 1.00 2 2454 1409 0.90 3 2581 1478 1.00 4 2711 1640 1.00 5 2744 1622 1.00 UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS REACTIONS FOR TOTAL LOADS CASE BRG#1 BRG#2 1 1844 5124 2 635 1729 3 862 1802 4 708 1955 5 725 1939 REACTIONS FOR DEAD LOAD CASE BRG#1 BRG#2 1 635 1729 2 635 1729 3 635 1729 4 635 1729 5 635 1729 REACTIONS FOR LIVE LOAD CASE BRG#1 BRG#2 1 1209 3395 2 0 0 3 227 73 4 73 227 5 90 210 MINIMUM BEARING SIZES (IN) BRG# 1 BRG# 2 4.000 4.000 CONCENTRATED LOADS SPAN TYPE W1 (LBS) Xl (FT) MIN BRG (IN) 1 DEAD 1626.7 4.500 4.000 1 LIVE 3253.3 4.500 4.000 LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM 1 1 0.051 0.308 L/1444 0.077 0.411 L/955 2 1 0.000 0.308 0.026 0.411 L/2820 0.026 0.039 3 1 0.003 0.308 L/23937 0.029 0.411 L/2535 Page 3 1453-275-0P12-HDR H1.dsn 4 1 0.003 0.308 L/23937 0.029 0.411 L/2523 5 1 0.004 0.308 L/20039 0.030 0.411 L/2472 **** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 **** **** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. **** **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . STRESS INDICES CASE MSI VSI 1 0.549 0.648 2 0.205 0.244 3 0.194 0.230 4 0.204 0.255 5 0.207 0.252 SLENDERNESS RATIO = 2.71 LIMIT = 10.00 VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR UNCERTAINTIES, PLEASE CONTACT LP. THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS. USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION. • • Page 1 C:\Users\NWUD\Desktop\NWUD OFFICE\(STONEBRIDGE HOMES)\JOB 1453\1453-275-OP12-BEAMS\1453-275-OP12-HDI LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2012.1 06/12/13 15:01:21 WARNING *** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY *** WOOD-E DESIGN 2012.1 EXPIRES ON 3/31/2014. LP WILL MAKE AVAILABLE TO ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES, INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS. COMPANY: STONEBRIDGE HOMES JOB ID: 1453-275-0P12-HDR H2 STATE: OR CODE: IBC PRODUCT: 2-PLY 1-3/4" X 9-1/2" LP LVL 2950Fb-2.OE DESIGN CRITERIA FOR ROOF BEAM (UNFACTORED LOADS) LIVE DEAD SPAN (L) SPAN (R) ALLOWABLE DEFLECTION (PSF) (PSF) CARRIED CARRIED SLOPE LOADING LIVE TOTAL 30 15 0.000' 0.000' 0.00 TOP L/240 L/180 SPAN CARRIED IS NOT CONTINUOUS. ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD ACTUAL 5599 12600 4744 0.167 0.252 ALLOWABLE 10500 13282 6428 0.408 0.544 STRESS INDICES 0.533 0.949 0.738 L/588 L/389 LOAD CASE 1 1 1 1 1 **** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS. **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . NOTES CONNECTION *** DESIGN ASSUMES COMPONENTS CARRIED ARE APPLIED TO TOP EDGE OF BEAM, SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY. ***ATTACH THE TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT 12" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR HALF FROM EACH FACE. NAILS MAY BE COMMON OR BOX NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131" 16d SINKERS (3-1/4") MAY BE USED, BUT HALF MUST BE DRIVEN FROM EACH FACE. *** CONCENTRATED LOADS MUST BE EQUALLY DISTRIBUTED TO ALL PLIES. ADDITIONAL FASTENERS MAY BE REQUIRED. *** COMPRESSION EDGE BRACING REQUIRED AT 24" O.C. OR LESS. *** THIS LVL BEAM HAS BEEN DESIGNED TO SUPPORT A 300 LBS CONCENTRATED LOAD ACTING OVER 2.5 X 2.5 FT (6.25 SQ FT) STRUCTURAL GEOMETRY SPAN 1 8.500' TOTAL SPAN: 8.50 FT LOAD PATTERNS CASE SPAN SHAPE TYPE SOURCE LOADING Wl W2 X1 (FT) X2 (FT) ALL 1 UNIF DEAD ROOF TOP 330.0 PLF 0.000 3.500 Page 2 1453-275-0P12-HDR H2.dsn +ALL 1 UNIF WEIGHT BEAM 9.5 PLF 0.000 8.500 ALL 1 CONC DEAD ROOF TOP 1590.7 LBS 3.500 1 1 UNIF LIVE ROOF TOP 660.0 PLF 0.000 3.500 1 1 CONC LIVE ROOF TOP 3181.3 LBS 3.500 2 1 UNIF LIVE ROOF TOP 0.0 PLF 0.000 3.500 2 1 CONC LIVE ROOF TOP 0.0 LBS 3.500 3 1 UNIF LIVE ROOF TOP 120.0 PLF 0.333 2.833 4 1 UNIF LIVE ROOF TOP 120.0 PLF 5.667 8.166 5 1 UNIF LIVE ROOF TOP 120.0 PLF 2.150 4.650 + INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF. SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF 1 12600 4744 1.00 2 4251 1607 0.90 3 4506 1855 1.00 4 4421 1659 1.00 5 4744 1788 1.00 UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS REACTIONS FOR TOTAL LOADS CASE BRG#1 BRG#2 1 5599 2719 2 1893 933 3 2137 989 4 1949 1177 5 2073 1053 REACTIONS FOR DEAD LOAD CASE BRG#1 BRG#2 1 1893 933 2 1893 933 3 1893 933 4 1893 933 5 1893 933 REACTIONS FOR LIVE LOAD CASE BRG#1 BRG#2 1 3706 1786 2 0 0 3 244 56 4 56 244 5 180 120 MINIMUM BEARING SIZES (IN) BRG# 1 BRG# 2 4.000 4.000 CONCENTRATED LOADS SPAN TYPE Wl (LBS) X1 (FT) MIN BRG (IN) 1 DEAD 1590.7 3.500 4.000 1 LIVE 3181.3 3.500 4.000 LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM 1 1 0.167 0.408 L/588 0.252 0.544 L/389 2 1 0.000 0.408 0.085 0.544 L/1149 0.085 0.128 3 1 0.006 0.408 L/16943 0.091 0.544 L/1077 • Page 3 1453-275-0P12-HDR H3.dsn STRESS INDICES CASE MSI VSI 1 0.174 0.259 2 0.084 0.125 3 0.126 0.178 4 0.160 0.243 SLENDERNESS RATIO = 2.71 LIMIT = 10.00 VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR UNCERTAINTIES, PLEASE CONTACT LP. THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS. USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION. Page 3 1453-275-0P12-HDR H4.dsn RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR UNCERTAINTIES, PLEASE CONTACT LP. THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED MOOD PRODUCTS. USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION. Page 1 C:\Users\NWUD\Desktop\NWUD OFFICE\(STONEBRIDGE HOMES)\JOB 1453\1453-275-0P12-BEAMS\1453-275-OP12-HDI LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2012.2 06/14/13 09:29:43 WARNING *** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY *** WOOD-E DESIGN 2012.2 EXPIRES ON 3/31/2014. LP WILL MAKE AVAILABLE TO ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES, INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS. COMPANY: STONE BRIDGE HOMES NW LLC JOB ID: 1453-275-OP12-HDR H3 STATE: OR CODE: IBC PRODUCT: 2-PLY 1-3/4" X 9-1/2" LP LVL 2950Fb-2.0E DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS) LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION (PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL 40 15 NO 16.000' 0.000' TOP L/360 L/240 SPAN CARRIED IS NOT CONTINUOUS. ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD ACTUAL 2081 2317 1666 0.008 0.014 ALLOWABLE 9188 13282 6428 0.140 0.210 STRESS INDICES 0.226 0.174 0.259 L/6706 L/3732 LOAD CASE 1 1 1 1 1 **** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS. **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . NOTES CONNECTION *** DESIGN ASSUMES COMPONENTS CARRIED ARE APPLIED TO TOP EDGE OF BEAM, SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY. ***ATTACH THE TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT 12" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR HALF FROM EACH FACE. NAILS MAY BE COMMON OR BOX NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131" 16d SINKERS (3-1/4") MAY BE USED, BUT HALF MUST BE DRIVEN FROM EACH FACE. *** CONCENTRATED LOADS MUST BE EQUALLY DISTRIBUTED TO ALL PLIES. ADDITIONAL FASTENERS MAY BE REQUIRED. *** COMPRESSION EDGE BRACING REQUIRED AT EACH END OF COMPONENT. STRUCTURAL GEOMETRY SPAN 1 4.500' TOTAL SPAN: 4.50 FT LOAD PATTERNS CASE SPAN SHAPE TYPE SOURCE LOADING Wl W2 X1 (FT) X2 (FT) +ALL 1 UNIF DEAD FLOOR TOP 120.0 PLF 0.000 4.500 ALL 1 UNIF DEAD WALL TOP 100.0 PLF 0.000 4.500 +ALL 1 UNIF WEIGHT BEAM 9.5 PLF 0.000 4.500 ALL 1 CONC DEAD ROOF TOP 614.7 LBS 3.000 Page 2 1453-275-0P12-HDR H3.dsn +1 1 UNIF LIVE FLOOR TOP 240.0 PLF 0.000 4.500 1 1 CONC LIVE ROOF TOP 922.0 LBS 3.000 +2 1 UNIF LIVE FLOOR TOP 0.0 PLF 0.000 4.500 2 1 CONC LIVE ROOF TOP 0.0 LBS 3.000 +3 1 UNIF LIVE FLOOR TOP 320.0 PLF 0.000 4.500 4 1 CONC LIVE ROOF TOP 1229.3 LBS 3.000 + INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF. SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF 1 2317 1666 1.00 2 1008 726 0.90 3 1668 1146 1.00 4 2131 1559 1.00 UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS REACTIONS FOR TOTAL LOADS CASE BRG#1 BRG#2 1 1569 2081 2 721 926 3 1441 1646 4 1131 1746 REACTIONS FOR DEAD LOAD CASE BRG#1 BRG#2 1 721 926 2 721 926 3 721 926 4 721 926 REACTIONS FOR LIVE LOAD CASE BRG#1 BRG#2 1 847 1155 2 0 0 3 720 720 4 410 820 MINIMUM BEARING SIZES (IN) BRG# 1 BRG# 2 3.500 3.500 CONCENTRATED LOADS SPAN TYPE Wl (LBS) X1 (FT) MIN BRG (IN) 1 DEAD 614.7 3.000 3.000 1 LIVE 1229.3 3.000 3.000 LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION CASE SPAN ACTUAL ALLOW. LI? ACTUAL ALLOW. L/? INSTANT LONG-TERM 1 1 0.008 0.140 L/6706 0.014 0.210 L/3732 2 1 0.000 0.140 0.006 0.210 L/8418 0.006 0.009 3 1 0.005 0.140 L/11179 0.011 0.210 L/4808 4 1 0.006 0.140 L/9099 0.012 0.210 L/4378 **** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 **** **** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. **** **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . Page 3 1453-275-0P12-HDR H2.dsn 4 1 0.006 0.408 L/16943 0.091 0.544 L/1079 5 1 0.011 0.408 L/9201 0.096 0.544 L/1022 **** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 **** **** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. **** **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . STRESS INDICES CASE MSI VSI 1 0.949 0.738 2 0.356 0.278 3 0.339 0.289 4 0.333 0.258 5 0.357 0.278 SLENDERNESS RATIO = 2.71 LIMIT = 10.00 VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR UNCERTAINTIES, PLEASE CONTACT LP. THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS. USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION. Page 1 C:\Users\NWUD\Desktop\NWUD OFFICE\(STONEBRIDGE HOMES)\JOB 1453\1453-275-OP12-BEAMS\1453-275-0P12-HDI LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2012.2 06/14/13 09:32:28 WARNING *** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY *** WOOD-E DESIGN 2012.2 EXPIRES ON 3/31/2014. LP WILL MAKE AVAILABLE TO ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES, INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS. COMPANY: STONE BRIDGE HOMES NW LLC JOB ID: 1453-275-0P12-HDR H4 STATE: OR CODE: IBC PRODUCT: 2-PLY 1-3/4" X 9-1/2" LP LVL 2950Fb-2.0E DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS) LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION (PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL 40 15 NO 18.500' 0.000' TOP L/360 L/240 SPAN CARRIED IS NOT CONTINUOUS. ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD ACTUAL 4479 6640 3195 0.053 0.092 ALLOWABLE 9188 13282 6428 0.207 0.310 STRESS INDICES 0.488 0.500 0.497 L/1412 L/808 LOAD CASE 1 1 1 1 1 **** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS. **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . NOTES CONNECTION *** DESIGN ASSUMES COMPONENTS CARRIED ARE APPLIED TO TOP EDGE OF BEAM, SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY. ***ATTACH THE TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT 12" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR HALF FROM EACH FACE. NAILS MAY BE COMMON OR BOX NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131" 16d SINKERS (3-1/4") MAY BE USED, BUT HALF MUST BE DRIVEN FROM EACH FACE. *** COMPRESSION EDGE BRACING REQUIRED AT 24" O.C. OR LESS. STRUCTURAL GEOMETRY SPAN 1 6.500' TOTAL SPAN: 6.50 FT LOAD PATTERNS CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 X1 (FT) X2 (FT) ALL 1 UNIF DEAD ROOF TOP 341.0 PLF 0.000 6.500 +ALL 1 UNIF DEAD FLOOR TOP 138.8 PLF 0.000 6.500 ALL 1 UNIF DEAD WALL TOP 100.0 PLF 0.000 6.500 +ALL 1 UNIF WEIGHT BEAM 9.5 PLF 0.000 6.500 1 1 UNIF LIVE ROOF TOP 511.5 PLF 0.000 6.500 +1 1 UNIF LIVE FLOOR TOP 277.5 PLF 0.000 6.500 M Page 2 1453-275-0P12-HDR H4.dsn 2 1 UNIF LIVE ROOF TOP 0.0 PLF 0.000 6.500 +2 1 UNIF LIVE FLOOR TOP 0.0 PLF 0.000 6.500 +3 1 UNIF LIVE FLOOR TOP 370.0 PLF 0.000 6.500 4 1 UNIF LIVE ROOF TOP 682.0 PLF 0.000 6.500 + INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF. SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF 1 6640 3195 1.00 2 2839 1370 0.90 3 4622 2226 1.00 4 6125 2947 1.00 UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS REACTIONS FOR TOTAL LOADS CASE BRG#1 BRG#2 1 4479 4479 2 1915 1915 3 3118 3118 4 4132 4132 REACTIONS FOR DEAD LOAD CASE BRG#1 BRG#2 1 1915 1915 2 1915 1915 3 1915 1915 4 1915 1915 REACTIONS FOR LIVE LOAD CASE BRG#1 BRG#2 1 2564 2564 2 0 0 3 1203 1203 4 2217 2217 MINIMUM BEARING SIZES (IN) BRG# 1 BRG# 2 3.500 3.500 LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. LI? INSTANT LONG-TERM 1 1 0.053 0.207 L/1412 0.092 0.310 L/808 2 1 0.000 0.207 0.039 0.310 L/1891 0.039 0.059 3 1 0.025 0.207 L/3011 0.064 0.310 L/1161 4 1 0.046 0.207 L/1634 0.085 0.310 L/876 **** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 **** **** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. **** **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . STRESS INDICES CASE MSI VSI 1 0.500 0.497 2 0.237 0.237 3 0.348 0.346 4 0.461 0.458 SLENDERNESS RATIO = 2.71 LIMIT = 10.00 VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY Page 3 1453-275-0P12-HDR H5.dsn STRESS INDICES CASE MSI VSI 1 0.535 0.617 2 0.247 0.287 3 0.311 0.362 4 0.553 0.632 SLENDERNESS RATIO = 2.71 LIMIT = 10.00 VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR UNCERTAINTIES, PLEASE CONTACT LP. THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS. USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION. Page 1 C:\Users\NWUD\Desktop\NWUD OFFICE\(STONEBRIDGE HOMES)\JOB 1453\1453-275-0P12-BEAMS\1453-275-0P12-HDE LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2012.2 06/14/13 09:37:14 WARNING *** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY *** WOOD-E DESIGN 2012.2 EXPIRES ON 3/31/2014. LP WILL MAKE AVAILABLE TO ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES, INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS. COMPANY: STONE BRIDGE HOMES NW LLC JOB ID: 1453-275-OP12-HDR H5 STATE: OR CODE: IBC PRODUCT: 2-PLY 1-3/4" X 9-1/2" LP LVL 2950Fb-2.0E DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS) LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION (PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL 40 15 NO 18.500' 0.000' TOP L/360 L/240 SPAN CARRIED IS NOT CONTINUOUS. ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD ACTUAL 4415 7339 4063 0.035 0.060 ALLOWABLE 9188 13282 6428 0.174 0.260 STRESS INDICES 0.481 0.553 0.632 L/1806 L/1045 LOAD CASE 1 4 4 1 1 **** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS. **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . NOTES CONNECTION *** DESIGN ASSUMES COMPONENTS CARRIED ARE APPLIED TO TOP EDGE OF BEAM, SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY. ***ATTACH THE TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT 12" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR HALF FROM EACH FACE. NAILS MAY BE COMMON OR BOX NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131" 16d SINKERS (3-1/4") MAY BE USED, BUT HALF MUST BE DRIVEN FROM EACH FACE. *** CONCENTRATED LOADS MUST BE EQUALLY DISTRIBUTED TO ALL PLIES. ADDITIONAL FASTENERS MAY BE REQUIRED. *** COMPRESSION EDGE BRACING REQUIRED AT 24" O.C. OR LESS. STRUCTURAL GEOMETRY SPAN 1 5.500' TOTAL SPAN: 5.50 FT LOAD PATTERNS CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 X1 (FT) X2 (FT) +ALL 1 UNIF DEAD FLOOR TOP 138.8 PLF 0.000 5.500 ALL 1 UNIF DEAD WALL TOP 100.0 PLF 0.000 5.500 +ALL 1 UNIF WEIGHT BEAM 9.5 PLF 0.000 5.500 ALL 1 CONC DEAD ROOF TOP 1866.3 LBS 2.000 Page 2 1453-275-0P12-HDR H5.dsn +1 1 UNIF LIVE FLOOR TOP 277.5 PLF 0.000 5.500 1 1 CONC LIVE ROOF TOP 2799.5 LBS 2.000 +2 1 UNIF LIVE FLOOR TOP 0.0 PLF 0.000 5.500 2 1 CONC LIVE ROOF TOP 0.0 LBS 2.000 +3 1 UNIF LIVE FLOOR TOP 370.0 PLF 0.000 5.500 4 1 CONC LIVE ROOF TOP 3732.7 LBS 2.000 + INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF. SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF 1 7100 3965 1.00 2 2957 1659 0.90 3 4128 2330 1.00 4 7339 4063 1.00 UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS REACTIONS FOR TOTAL LOADS CASE BRG#1 BRG#2 1 4415 3143 2 1870 1361 3 2888 2379 4 4246 2719 REACTIONS FOR DEAD LOAD CASE BRG#1 BRG#2 1 1870 1361 2 1870 1361 3 1870 1361 4 1870 1361 REACTIONS FOR LIVE LOAD CASE BRG#1 BRG#2 1 2545 1781 2 0 0 3 1018 1018 4 2375 1357 MINIMUM BEARING SIZES (IN) BRG# 1 BRG# 2 3.500 3.500 CONCENTRATED LOADS SPAN TYPE Wl (LBS) Xl (FT) MIN BRG (IN) 1 DEAD 1866.3 2.000 3.000 1 LIVE 3732.7 2.000 3.000 LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. LI? INSTANT LONG-TERM 1 1 0.035 0.174 L/1806 0.060 0.260 L/1045 2 1 0.000 0.174 0.025 0.260 L/2483 0.025 0.038 3 1 0.012 0.174 L/5100 0.037 0.260 L/1672 4 1 0.034 0.174 L/1841 0.059 0.260 L/1057 **** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 **** **** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. **** **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . • Page 3 1453-275-0P12-HDR H7.dsn STRESS INDICES CASE MSI VSI 1 0.301 0.157 2 0.135 0.073 3 0.246 0.120 4 0.242 0.133 SLENDERNESS RATIO = 3.39 LIMIT = 10.00 VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR UNCERTAINTIES, PLEASE CONTACT LP. THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS. USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION. f 1 Page 1 C:\Users\NWUD\Desktop\NWUD OFFICE\(STONEBRIDGE HOMES)\JOB 1453\1453-275-OP12-BEAMS\1453-275-0P12-HD} LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2012.2 06/14/13 09:40:45 WARNING *** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY *** WOOD-E DESIGN 2012.2 EXPIRES ON 3/31/2014. LP WILL MAKE AVAILABLE TO ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES, INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS. COMPANY: STONE BRIDGE HOMES NW LLC JOB ID: 1453-275-OP12-HDR H6 STATE: OR CODE: IBC PRODUCT: 2-PLY 1-3/4" X 9-1/2" LP LVL 2950Fb-2.0E DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS) LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION (PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL 40 15 NO 18.500' 0.000' TOP L/360 L/240 SPAN CARRIED IS NOT CONTINUOUS. ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD ACTUAL 3277 5069 2812 0.037 0.066 ALLOWABLE 9188 13282 6428 0.207 0.310 STRESS INDICES 0.357 0.382 0.437 L/2004 L/1126 LOAD CASE 1 1 1 1 1 **** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS. **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . NOTES CONNECTION *** DESIGN ASSUMES COMPONENTS CARRIED ARE APPLIED TO TOP EDGE OF BEAM, SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY. ***ATTACH THE TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT 12" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR HALF FROM EACH FACE. NAILS MAY BE COMMON OR BOX NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131" 16d SINKERS (3-1/4") MAY BE USED, BUT HALF MUST BE DRIVEN FROM EACH FACE. *** CONCENTRATED LOADS MUST BE EQUALLY DISTRIBUTED TO ALL PLIES. ADDITIONAL FASTENERS MAY BE REQUIRED. *** COMPRESSION EDGE BRACING REQUIRED AT 24" O.C. OR LESS. STRUCTURAL GEOMETRY SPAN 1 6.500' TOTAL SPAN: 6.50 FT LOAD PATTERNS CASE SPAN SHAPE TYPE SOURCE LOADING WI W2 X1 (FT) X2 (FT) +ALL 1 UNIF DEAD FLOOR TOP 138.8 PLF 0.000 6.500 ALL 1 UNIF DEAD WALL TOP 100.0 PLF 0.000 6.500 +ALL 1 UNIF WEIGHT BEAM 9.5 PLF 0.000 6.500 ALL 1 CONC DEAD ROOF TOP 906.3 LBS 4.500 Page 2 1453-275-0P12-HDR H6.dsn +1 1 UNIF LIVE FLOOR TOP 277.5 PLF 0.000 6.500 1 1 CONC LIVE ROOF TOP 1359.5 LBS 4.500 +2 1 UNIF LIVE FLOOR TOP 0.0 PLF 0.000 6.500 2 1 CONC LIVE ROOF TOP 0.0 LBS 4.500 +3 1 UNIF LIVE FLOOR TOP 370.0 PLF 0.000 6.500 4 1 CONC LIVE ROOF TOP 1812.7 LBS 4.500 + INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF. SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF 1 5069 2812 1.00 2 2184 1217 0.90 3 3878 2073 1.00 4 4534 2489 1.00 UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS REACTIONS FOR TOTAL LOADS CASE BRG#1 BRG#2 1 2406 3277 2 1086 1434 3 2288 2637 4 1643 2689 REACTIONS FOR DEAD LOAD CASE BRG#1 BRG#2 1 1086 1434 2 1086 1434 3 1086 1434 4 1086 1434 REACTIONS FOR LIVE LOAD CASE BRG#1 BRG#2 1 1320 1843 2 0 0 3 1203 1203 4 558 1255 MINIMUM BEARING SIZES (IN) BRG# 1 BRG# 2 3.500 3.500 CONCENTRATED LOADS SPAN TYPE W1 (LBS) X1 (FT) MIN BRG (IN) 1 DEAD 906.3 4.500 3.000 1 LIVE 1812.7 4.500 3.000 LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM 1 1 0.037 0.207 L/2004 0.066 0.310 L/1126 2 1 0.000 0.207 0.029 0.310 L/2569 0.029 0.043 3 1 0.025 0.207 L/3011 0.054 0.310 L/1388 4 1 0.025 0.207 L/2982 0.054 0.310 L/1382 **** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 **** ****TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. **** **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . • Page 3 1453-275-OP12-HDR H8.dsn LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR UNCERTAINTIES, PLEASE CONTACT LP. THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS. USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION. T � , Page 1 C:\Users\NWUD\Desktop\NWUD OFFICE\(STONEBRIDGE HOMES)\JOB 1453\1453-275-OP12-BEAMS\1453-275-OP12-HDI LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2012.2 06/14/13 09:47:04 WARNING *** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY *** WOOD-E DESIGN 2012.2 EXPIRES ON 3/31/2014. LP WILL MAKE AVAILABLE TO ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES, INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS. COMPANY: STONE BRIDGE HOMES NW LLC JOB ID: 1453-275-0P12-HDR H7 STATE: OR CODE: IBC PRODUCT: 2-PLY 1-3/4" X 11-7/8" LP LVL 2950Fb-2.OE DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS) LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION (PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL 40 15 NO 0.000' 0.000' TOP L/360 L/240 SPAN CARRIED IS NOT CONTINUOUS. ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD ACTUAL 1367 6094 1260 0.162 0.278 ALLOWABLE 9188 20246 6035 0.540 0.810 STRESS INDICES 0.149 0.301 0.157 L/1197 L/701 LOAD CASE 1 1 1 1 1 **** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS. **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . NOTES CONNECTION *** DESIGN ASSUMES COMPONENTS CARRIED ARE APPLIED TO TOP EDGE OF BEAM, SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY. ***ATTACH THE TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT 12" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR HALF FROM EACH FACE. NAILS MAY BE COMMON OR BOX NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131" 16d SINKERS (3-1/4") MAY BE USED, BUT HALF MUST BE DRIVEN FROM EACH FACE. *** CONCENTRATED LOADS MUST BE EQUALLY DISTRIBUTED TO ALL PLIES. ADDITIONAL FASTENERS MAY BE REQUIRED. *** COMPRESSION EDGE BRACING REQUIRED AT 24" O.C. OR LESS. *** NO WALL LOAD WAS USED. STRUCTURAL GEOMETRY SPAN 1 16.500' TOTAL SPAN: 16.50 FT LOAD PATTERNS CASE SPAN SHAPE TYPE SOURCE LOADING Wl W2 X1 (FT) X2 (FT) ALL 1 UNIF DEAD ROOF TOP 37.7 PLF 0.000 16.500 +ALL 1 UNIF WEIGHT BEAM 11.9 PLF 0.000 16.500 Page 2 1453-275-0P12-HDR H7.dsn ALL 1 CONC DEAD FLOOR TOP 257.7 LBS 6.000 1 1 UNIF LIVE ROOF TOP 56.5 PLF 0.000 16.500 1 1 CONC LIVE FLOOR TOP 515.5 LBS 6.000 2 1 UNIF LIVE ROOF TOP 0.0 PLF 0.000 16.500 2 1 CONC LIVE FLOOR TOP 0.0 LBS 6.000 3 1 CONC LIVE FLOOR TOP 687.3 LBS 6.000 4 1 UNIF LIVE ROOF TOP 75.3 PLF 0.000 16.500 + INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF. SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF 1 6094 1260 1.00 2 2469 529 0.90 3 4983 968 1.00 4 4890 1065 1.00 UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS REACTIONS FOR TOTAL LOADS CASE BRG#1 BRG#2 1 1367 1156 2 573 503 3 1010 752 4 1194 1124 REACTIONS FOR DEAD LOAD CASE BRG#1 BRG#2 1 573 503 2 573 503 3 573 503 4 573 503 REACTIONS FOR LIVE LOAD CASE BRG#1 BRG#2 1 794 654 2 0 0 3 437 250 4 621 621 MINIMUM BEARING SIZES (IN) BRG# 1 BRG# 2 3.500 3.500 CONCENTRATED LOADS SPAN TYPE WI (LBS) X1 (FT) MIN BRG (IN) 1 DEAD 257.7 6.000 3.000 1 LIVE 687.3 6.000 3.000 LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM 1 1 0.162 0.540 L/1197 0.278 0.810 L/701 2 1 0.000 0.540 0.115 0.810 L/1691 0.115 0.173 3 1 0.097 0.540 L/2001 0.212 0.810 L/916 4 1 0.120 0.540 L/1623 0.235 0.810 L/828 **** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 **** **** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. **** **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . Page 3 1453-275-0P12-HDR H6.dsn STRESS INDICES CASE MSI VSI 1 0.382 0.437 2 0.183 0.210 3 0.292 0.322 4 0.341 0.387 SLENDERNESS RATIO = 2.71 LIMIT = 10.00 VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR UNCERTAINTIES, PLEASE CONTACT LP. THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS. USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION. al Page 1 C:\Users\NWUD\Desktop\NWUD OFFICE\(STONEBRIDGE HOMES)\JOB 1453\1453-275-0P12-BEAMS\1453-275-0P12-HD1 LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2012.2 06/14/13 11:05:44 WARNING *** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY *** WOOD-E DESIGN 2012.2 EXPIRES ON 3/31/2014. LP WILL MAKE AVAILABLE TO ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES, INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS. COMPANY: STONE BRIDGE HOMES NW LLC JOB ID: 1453-275-0P12-HDR H8 STATE: OR CODE: IBC PRODUCT: 3-PLY 1-3/4" X 9-1/2" LP LVL 2950Fb-2.0E DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS) LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION (PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL 40 15 NO 18.500' 0.000' TOP L/360 L/240 SPAN CARRIED IS NOT CONTINUOUS. ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD ACTUAL 5955 14843 5401 0.150 0.222 ALLOWABLE 13781 19924 9643 0.274 0.410 STRESS INDICES 0.432 0.745 0.560 L/657 L/444 LOAD CASE 1 1 1 1 1 **** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS. **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . NOTES CONNECTION *** DESIGN ASSUMES COMPONENTS CARRIED ARE APPLIED TO TOP EDGE OF BEAM, SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY. ***ATTACH TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT 12" OC. FROM ONE FACE ONLY. STAGGER ROWS. FLIP BEAM AND ATTACH THE THIRD PLY WITH 2 ROWS OF l6d (3-1/2") NAILS AT 12" OC. TO THE UN-NAILED SIDE OF THE FIRST TWO PLIES. STAGGER ROWS. NAILS MAY BE COMMON OR BOX NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131". 16d SINKERS (3-1/4") MAY BE USED. *** CONCENTRATED LOADS MUST BE EQUALLY DISTRIBUTED TO ALL PLIES. ADDITIONAL FASTENERS MAY REQUIRED. *** COMPRESSION EDGE BRACING REQUIRED AT 24" O.C. OR LESS. STRUCTURAL GEOMETRY SPAN 1 8.500' TOTAL SPAN: 8.50 FT LOAD PATTERNS CASE SPAN SHAPE TYPE SOURCE LOADING Wl W2 Xl (FT) X2 (FT) +ALL 1 UNIF DEAD FLOOR TOP 138.8 PLF 0.000 8.500 ALL 1 UNIF DEAD WALL TOP 100.0 PLF 0.000 8.500 +ALL 1 UNIF WEIGHT BEAM 14.3 PLF 0.000 8.500 • .4 I Page 2 1453-275-0P12-HDR H8.dsn ALL 1 CONC DEAD FLOOR TOP 857.2 LBS 3.000 ALL 1 CONC DEAD FLOOR TOP 656.2 LBS 4.000 +1 1 UNIF LIVE FLOOR TOP 370.0 PLF 0.000 8.500 1 1 CONC LIVE FLOOR TOP 2285.8 LBS 3.000 1 1 CONC LIVE FLOOR TOP 1749.8 LBS 4.000 +2 1 UNIF LIVE FLOOR TOP 0.0 PLF 0.000 8.500 2 1 CONC LIVE FLOOR TOP 0.0 LBS 3.000 2 1 CONC LIVE FLOOR TOP 0.0 LBS 4.000 + INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF. SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF 1 14843 5401 1.00 2 4741 1757 0.90 UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS REACTIONS FOR TOTAL LOADS CASE BRG#1 BRG#2 1 5955 4889 2 1977 1687 REACTIONS FOR DEAD LOAD CASE BRG#1 BRG#2 1 1977 1687 2 1977 1687 REACTIONS FOR LIVE LOAD CASE BRG#1 BRG#2 1 3978 3203 2 0 0 MINIMUM BEARING SIZES (IN) BRG# 1 BRG# 2 3.500 3.500 CONCENTRATED LOADS SPAN TYPE W1 (LBS) X1 (FT) MIN BRG (IN) 1 DEAD 857.2 3.000 3.000 1 DEAD 656.2 4.000 3.000 1 LIVE 2285.8 3.000 3.000 1 LIVE 1749.8 4.000 3.000 LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM 1 1 0.150 0.274 L/657 0.222 0.410 L/444 2 1 0.000 0.274 0.072 0.410 L/1373 0.072 0.108 **** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 **** **** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. **** **** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR TWICE THE LENGTH FOR CANTILEVERS (2L) . STRESS INDICES CASE MSI VSI 1 0.745 0.560 2 0.264 0.202 SLENDERNESS RATIO = 1.81 LIMIT = 10.00 VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED