Report Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: Jurisdiction:
22D1 1- ( ) L-VC
Site Address:
IIOH A..)3 fl cfi -HA\ Cr
Subdivision/Lot#:
MiNervl l It- *�22
and/or
Map and Tax Lot#:
By my signature below, I certify that all of the permanently installed lighting fixtures in the
above mentioned building contain high-efficacy lamps. Screw-in compact fluorescent and LED
lamps comply with this requirement. (Oregon Residential Specialty Code N1107.2)1
Signature: \ Date: 1\ lo
/i g
Owne eneral :- ractor/Authorized Agent
Print Name: Doke �:{ gS
' ORSC Section N1107.2. High-efficacy lamps. All permanently installed lighting fixtures shall contain high-
efficacy lamps. Screw-in compact fluorescent and LED lamps comply with this requirement.
The building official shall be notified in writing at the final inspection that the permanently installed lighting fixtures
have met this requirement.
Exception: Two permanently installed lighting fixtures are not required to have high-efficacy lamps.
1:\Building\Forms\RES-HighEfficiencyLightingAcknowledgement_022018
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
I, per, CZACinS , am the general contractor or the owner-builder
at the following address:
Site Address: t OA imv 6 V1 CA-
City:
-7-4aerv3
Permit#: �cr ton
Subdivision/Lot#:
Jr Oces(nsts k'c' *22
and/or
Map and Tax Lot#:
To conform with the 2017 Oregon Residential Specialty Code (ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes, the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
Signature: iDate: i./ ►a l!g
nera',Co 'actor or Owner-Builder
1:\Building\Form\RES-MoistureContentAcknowledgement_022018
S i v i (j o // 1L/ SIlit1,4-, /0 )4 1(L
Form 640S 2017
Completion Certification—Site Inspection �� �, True
New Homes Program—Single Family
of Oregon
To be completed by Verifier
CLEAResult is a Program Management Contractor for Energy Trust of Oregon,Inc.
Payment information'... _
Incentive Payee Company Name: I Performance Insulation and Energy Its this payment redirected?: IYes
Builder or Company: Windwood Construction Redirect to Name:
Veriier Payee Company Name: Performance Insulation and Energy Redirect Payee Com Performance Insulation and Energy
Affordable Housing No
Solar Ready Builder Incentive: No (Solar ReadyVerifier Inc4No
Site Information
Development Abbey Heights [Lot �Axis ID: I IREM/Rate®ID:
Address:
Street Line 2 Multi-Family No City: Portland State: OR Zip: 97229
Total conditioned area(sq.ft.): 2,014 House Volume: ] 16,016 Housing Type: Detached single family
Number of Stones: 12 Number of Bedrooms: 3 Foundation Type: Crawtspace
Electric Provider: Portland General Electric Gas Provider: NW Natural Gas
Solar installed (None Solar Installer Name/Company:
Blue shaded fields are required for EPS sheet
Verification Type Actual Model Equipment Details A Notes
Slab Perimeter Insulation R- 0.0 Slab Under Insulation R-
Insulation
Framed Floor R- 30.0 Secondary Framed Floor R- 30.0
Above Grade Wall Insulation R- 21.0 Below Grade Wall Insulation R-
Flat Ceiling Insulation R- 38.0 Vaulted Ceiling Insulation R-
Windows Windows U- 0.3 SHGC:10.3 Total window area: 1297
Cooling Air Conditioning SEER: 0 Model#:
Primary Heating System Details AFUE: 95 Brand Trane
Type: Gas Furnace HSPF: Model#: TDH1B065A9421A`
Heating Fuel: Gas SEER:
Primary Heat
Source Comment: COP:
Location: Garage or ope Outdoor Unit(for heat pumps)
ECM: No Model#: 1
AHRI Certificate:3670536 #of Systems 11
Gallons: 150 Brand: AOSmith
Water Heater Type Storage EF: 1.60 Model#: GCG50400
Water Heating Fuel Gas Location: 'Garage or ope AHRI Certificate:8049158
Ducts and Duct Location (Unconditioned %duds inside: Duct Leakage(CFM)IS 50Pa �;"� r
Testing
Infiltration Air Changes per Hour(ACH)Q 50Pa: 3.47 1
Ventilation Ventilation Type HRV/ERV Model:
Supply Side-Air Cyder Airflow measured or why untestable? 'Roof Termination
Appliances
Refrigerator kWh/yr Model:
ENERGY STAR Diswasher kWh/yr Model:
Percent High Efficacy Interior Lighting(%) 100% Thermostat
Showerhead 1.5 GPH 1 Showerwand 1.5 GPH I Showerhead 1.6 GPH I IShowerhead 1.75 GPH 1