Permit (58) CITY OF TIGARD MECHANICAL PERMIT 1 . ' COMMUNITY DEVELOPMENT104 Permit#: MEC2019 00035 Date Issued: 01/17/2019 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 1S1260000300 Jurisdiction: Tigard Site address: 9567 SW WASHINGTON SQUARE RD BO3B Project: Na Hoku Subdivision: None Lot: None Project Description: Mechanical for TI: Extending duct work and installing new grilles. Contractor: TRI TECH HEATING INC Owner: PPR WASHINGTON SQUARE LLC 6603 NE 137TH AVE PO BOX 847 VANCOUVER,WA 98652 CARLSBAD, CA 92018 PHONE: 360-891-2002 PHONE: 503-580-3845 FAX: FEES Specifics: Description Date Amount Type of Use: COM Permit Fee 01/17/2019 $474.71 Class of Work: ALT Type of Const: Plan Review 01/17/2019 $118.68 Occupancy Grp: Occupancy Load: 12%State Surcharge-Mechanical 01/17/2019 $56.97 Stories: Info Process/Archiving-Lg$2.00(over 01/17/2019 $2.00 11x17) Project Valuation: $14,966.00 Fuel Air Handlers Fuel Types: Units< 10000 cfm: Gas Pressure: Units> 10000 cfm: Furnaces Boilers&Compressors Furnaces< 100K BTU: 0-3 HP: Furnaces>=100K BTU: 3-15 HP: Floor Furnaces: 15-30 HP: Unit Heaters: 30-50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: Heat Pump: Appliances Vent Fans: Vent Systems: Total $652.36 Hoods: Comm Incinerators: Woodstoves: Gas Fireplaces: Required Items and Reports(Conditions) Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc: Duct Work: 1 Fire/Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 502.32.987 .• .:00.332. - . Issued By: 'e ature:- ........_ - 4: 1/ Call 5o /7,./Ci',.. ..''' ,:-....... 4 /....T.r.._ .639.4175 by 7:00 a.m.for the next available inspection dat . This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Mechanical Permit Application FO R O I I I( I I. .F ()NI 1 Eiew PermitNo.. l — dtDf /" ) -r/I131SWHallBlvdTigard,OR 97223FIE�. ;? " I Phone: 503.718.2439 Fax: 503.598.196 Date/By: Other Permit: A` r i 1 U i1 it a Inspection Line: 503.639.4175 'IPA; Date Ready/By: See Page 2 for Internet: www.tigard-or.gov JAN t"n�� Notified/Method: Supplemental Information TYPE OF W COMMERCIAL FEE* SCHEDULE �-USE CHECKLIST Mechanical permit fees*are based on the value of the work ❑New construction ®Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition 0 Other: mechanical materials,equipment,labor,overhead,and profit. Value:$ 14 Q(.(.(.►cc) CATEGORY OF CONSTRUCTION RESIDENTIAL EQUIPMENT,SYSTEMS FEES* ❑ 1-and 2-family dwelling 4 Commercial/industrial 0 Accessory building For special information use checklist. ❑Multi-family 0 Master builder 0 Other: Description Qty. Ea. Total 475-4,-7{ JOBB SITE: "INFORMATION AND LOCATION Heating/cooling: a"t " n Air conditioning 46.75 Job site address: Wf ea ►I S g4 pot Ct 41' )C)3 1s? Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP: t$1.1"-C1 _ )g,, C 22.3 Furnace 100,000+BTU(ducts/vents) 54.91 Heat pump 61.06 Suite/bldg./apt.no.: Project name: (.L '� we/Jim./ Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Subdivision: Lot no.: Other: 23.32 Other fuel appliances: Tax map/parcel no.: Water heater 23.32 DE RIPTION OF ORK Gas fireplace/insert 33.39 Flue vent for water heater or gas (6 fireplace 23.32 Log Log lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 Other: 23.32 ❑ PROpERTY OWNER 0 TENANT Environmental exhaust and ventilation: Name: Range hood/other kitchen equipment 33.39 Address: Clothes dryer exhaust 33.39 City/State/ZIP: Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 23.32 Phone:( ) Fax:( ) Attic/crawlspace fans 23.32 {."'APPLICANT 0 CONTACT PERSON Other: 23.32 �+ Fuel piping: Business name: 1 c\Vzeir 1. $14.15 for first four;$4.03 for each additional Contact name: 7(3\11 (L ^ Furnace,etc. Address: lip 3 N E 131.11`"^ p JE Gas heat pump Wall/suspended/unit heater City/State/ZIP: UCD(AA,Aa(" tArA Of Wpe2_ Water heater Phone:(..),0 ) QIg1- c200a Fax::(Nor)) soil- /qI a Fireplace Range E-mail: Too Y &Tr(=pi1t4. *c,„p.,, Barbecue / OR Clothes dryer(gas) Business name: II.' Id��C..� g\ Other: MECHANICAL PTIt1aTFEES* Address: 6,4903 N t t31'13. fosjF. Subtotal City/State/ZIP: t� yN�t,�%)� , ec IU,�- t,� (:L �'��2 Minimum permit fee($90.00) V�" ' Plan review(25%of permit fee) Phone:(%O) ell,- a. Fax:(.:.. 0,0) 3 i—iiii6 State surcharge(12%of permit fee) CCB lic.: i t" TOTAL PERMIT FEE This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Authorized Signature:• f/�� _.. * Fee methodology set by Tri-County Building Industry Service Board Print name:'....--- ame:�1� z ,e4 Date:/,/7-757 1:\Building\Pennits IEC Permit p_040t13.doc 440-4617T(11/02/COM/WEB) City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 9567 SW WASHINGTON SQUARE RD B03B, March 15, 2019 at 9:10:59 AM TIGARD, OR, 97223 Record Type: Record ID: Commercial - Mechanical MEC2019-00035 Inspection Type: Inspector: 699 Mechanical final Chip Barnett Result: PASS - NoCofO Comments: Violation Summary: Inspector Contractor