Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (8)
RECEIVED OFFICECO V JAN 2 2019 CITY OF r Ilar} D BUILDING DIVISION mss•ij +ii i . IF/VIRE `1�''AT T t • •s % PROTECTION, INC. I{.♦ 9095 S.W. Burnham Tigard, OR 97223 MORPHE WASH SQ 9577 SW WASHINGTON SQUARE RD #B07 TIGARD, OR 97223 FIRE PROTECTION EQUIPMENT SUBMITTAL • ti. cu Worldwide Contacts www.tyco-fire.com Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers . Quick Response, Standard Coverage - General NOTICE The TYCO Series TY-FRB Sprinklers r , " ` ' Description described herein must be installed #i and maintained in compliance with The TYCO Series TY-FRB,5.6 K-factor, this document, as well as with the Upright (TY313) and Pendent (TY323) applicable standards of the National Sprinklers described in this data sheet Fire Protection Association,in addition wi t are quick response,standard coverage, to the standards of any other authori- �. '?-:-i- - : t decorative 3 mm glass bulb-type spray ties having jurisdiction.Failure to do so sprinklers designed for use in light or may impair the performance of these ordinary hazard,commercial occupan- devices. cies such as banks, hotels, and shop The owner is responsible for main 1 `'"-` ping malls. taining their fire protection system The recessed version of the Series and devices in proper operating con- TY-FRB Pendent Sprinkler, where dition. Contact the installing contrac- applicable, is intended for use in areas tor or product manufacturer with any with a finished ceiling. This recessed questions. pendent sprinkler uses one of the following: Sprinkler ti • A two-piece Style 15 Recessed Escutcheon with recessed adjust- Identification mentftuph te in. sits mm) from Number (SIN) the flush pendent position. • A two-piece Style 20 Recessed TY313. . . . Upright 5.6K,1/2 in. NPT Escutcheon with recessed adjust- TY323. . . .Pendent 5.6K,1/2 in. NPT ment up to 1/2 in. (12,7 mm) from the flush pendent position. Technical The adjustment provided by theOperation Recessed Escutcheon reduces the Data accuracy to which the fixed pipe drops The glass bulb contains a fluid which to the sprinklers must be cut. Approvals expands when exposed to heat.When Refer to Table A the rated temperature is reached, the Intermediate level versions of Series fluid expands sufficiently to shatter the TY-FRB Sprinklers are described in Maximum Working Pressure glass bulb, allowing the sprinkler to Technical Data Sheet TFP357. Sprin- 175 psi(12.1 bar) activate and water to flow. kler guards and shields are described 250 psi(17.2 bar)* in Technical Data Sheet TFP78O. *The maximum working pressure of 250 psi(17.2 bar) Design only applies to the listing by Underwriters Laborato- ries,Inc.(UL). Discharge Coefficient Criteria IMPORTANT K=5.6 GPM/psi'/=(80,6 LPM/bar'%) The TYCO Series TY FRB,5.6 K-factor, Refer to Technical Data Sheet Temperature Rating Upright (TY313) and Pendent (TY323) . TFP2300 for warnings pertaining to Refer to Table A Sprinklers are intended for fire protec- regulatory and health information. tion systems designed in accordance Always refer to Technical Data Finishes with the standard installation rules y Sprinkler:Refer to Table B Sheet TFP700 for the "INSTALLER recognized by the applicable Listing or WARNING" that provides cautions Recessed Escutcheon:White Coated, Approval agency (such as, UL Listing with respect to handling and instal- Black Coated,Chrome Plated,or Brass is based on the requirements of NFPA lation of sprinkler systems and corn- Plated 13, and FM Approval is based on the ponents. Improper handling and Physical Characteristics requirements of FM's Loss Prevention installation can permanently damage Frame Bronze Data Sheets).Only the Style 15 or Style a sprinkler system or its compo- Button Brass/Copper 20 Recessed Escutcheon is to be used nents and cause the sprinkler to fail Sealing Assembly...Stainless Steel w/TEFLON for recessed pendent installations. to operate in a fire situation or cause Bulb Glass it to operate prematurely. Compression Screw Bronze Deflector Bronze Page 1 of 4 AUGUST 2018 TFP172 TFP172 Page 2 of 4 ' Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED ' Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* cr I 5 �' 7/16" Y = �— / (11,1 mm) t imi�� 4 i NOMINAL 2" , /le.• MAKE-IN I (50,82mm) 1 `2 p• 2" „J Ili1-3/8”�� (50,8 mm) (34,9 mm) I_� 3 WRENCH / 1 FLATS t 1/2"NPT** DEFLECTOR* 2-7/8"(73,0 mm)DIA. — CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT(TY313)AND PENDENT(TY323)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Installation Step 2. With pipe-thread sealant applied to the pipe threads, hand- The TYCO Series TY-FRB,5.6 K-factor, tighten the sprinkler into the sprinkler WRENCH RECESS Upright (TY313) and Pendent (TY323) fitting. (USE ONLY Sprinklers must be installed in accor- Step 3. Tighten the sprinkler into the END"A") dance with this section. sprinkler fitting using only the W-Type ^� General Instructions 6 Sprinkler Wrench(Figure 2).With ref- FIGURE 2 Do not install any bulb-type sprin- erence to Figure 1,apply the W-Type 6 W-TYPE 6 kler if the bulb is cracked or there is Sprinkler Wrench to the wrench flats. SPRINKLER WRENCH a loss of liquid from the bulb.With the Torque sprinklers 7 to 14 lb-ft (9,5 to sprinkler held horizontally, a small air 19,0 N•m). bubble should be present. The diam- Recessed Pendent Sprinklers WRENCH eter of the air bubble is approximately The Series TY-FRB Recessed Pendent RECESS 1/16 in.(1,6 mm)for the 135°F(57°C)and Sprinklers must be installed in accor- 3/32 in. (2,4 mm)for the 286°F(141°C) dance with the following instructions. `�, temperature ratings. Step A. After installing the Style 15 A leak-tight 1/2 in. NPT sprinkler joint or Style 20 Mounting Plate over the should be obtained by applying a sprinkler threads,and with pipe-thread minimum to maximum torque of 7 to sealant applied to the pipe threads, ., 14 Ib ft(9,5 to 19,0 N m). Higher levels hand-tighten the sprinkler into the t `�� of torque can distort the sprinkler Inlet sprinkler fitting. with consequent leakage or impairment Step B. Tighten the sprinkler into the PUSH WRENCH of the sprinkler. IN TO ENSURE sprinkler fitting using only the W-Type ENGAGEMENT Do not attempt to compensate for 7 Recessed Sprinkler Wrench (Figure WITH SPRINKLER insufficient adjustment in the Escutch- 3).With reference to Figure 1,apply the WRENCHING AREA eon Plate by under- or over-tightening W-Type 7 Recessed Sprinkler Wrench the sprinkler. Re-adjust the position of to the sprinkler wrench flats. Torque FIGURE 3 the sprinkler fitting to suit. sprinklers 7 to 14 lb-ft(9,5 to 19,0 N•m). W-TYPE 7 RECESSEDUpright and Pendent Sprinklers Step C. After ceiling installation and SPRINKLER WRENNCHH The Series TY-FRB Upright and finishing,slide on the Style 15 or Style Pendent Sprinklers must be installed 20 Closure over the Series TY-FRB in accordance with the following Sprinkler and push the Closure over the instructions. Mounting Plate until its flange comes in Step 1.Install Pendent sprinklers in the contact with the ceiling. pendent position. Install upright sprin- . klers in the upright position. TFP172 Page 3 of 4 Care and 2-7/8" DIA. (73,0 mm) Maintenance DIA. • The TYCO Series TY-FRB,5.6 K-factor, FACE OF — (57,2 mm) — Upright (TY313) and Pendent (TY323) SPRINKLER Sprinklers must be maintained and ser- FITTING 5/8"(15,9 mm) viced in accordance with this section. + \ n FLUSH Before closing a fire protection system 3/8±5/16" ,,,�{I —1 �' main control valve for maintenance (9,5±7,9 mm) 1U r 7 work on the fire protection system / J that it controls, obtain permission to /_� 1/8" shut down the affected fire protection MOUNTING systems from the proper authorities SURFACE (3,2 mm) and notify all personnel who may beCLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) affected by this action. TY-FRB PLATE 3/4"(19,1 mm) Absence of the outer piece of an FIGURE 4 escutcheon,clearancece, wole, canh is usedelasprinklertcover SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) a hole, delay operation in a fire situation. WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only 2-7/8" DIA. cleaned by means of gently dusting (73,0 mm) with a feather duster; otherwise, non- FACE OF operation in the event of a fire or inad- SPRINKLER 2-1/4" DIA. _ vertent operation may result. FITTING (57,2 mm) Sprinklers which are found to be 5/16±1/4" leaking or exhibiting visible signs of (7,9±6,4 mm) 1/2"(12,7 mm) corrosion must be replaced. / i FLUSH Automatic sprinklers must never be .4- . ,7 � + painted, plated, coated, or other- wise altered after leaving the factory. I / / , Modified sprinklers must be replaced. MOUNTING �l� 1/8" J t Sprinklers that have been exposed to SURFACE (3,2 mm) I corrosive products of combustion, but have not operated,should be replaced if they cannot be completely cleaned CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) by wiping the sprinkler with a cloth or TY-FRB PLATE 7/8"(22,2 mm) by brushing it with a soft bristle brush. FIGURE 5 Care must be exercised to avoid SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) damage to the sprinklers before, WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 during, and after installation. Sprin- RECESSED ESCUTCHEON klers damaged by dropping, striking, wrench twist/slippage,or the like,must Recessed Escutcheon be replaced. Also, replace any sprin- Limited Specify: Style 15 Recessed Escutch- kler that has a cracked bulb or that has warrant�/ eon with(specify")finish,P/N(specify`) lost liquid from its bulb. (Ref. Installa- 1 Specify: Style 20 Recessed Escutch- tion Section.) For warranty terms and conditions,visit eon with(specify*)finish,P/N(specify") The owner is responsible for the www.tyco-fire.com. *Refer to Technical Data Sheet TFP770 inspection,testing,and maintenance of their fire protection system and devicesOSprinkler Wrench in compliance with this document, as rdering Specify: W-Type 6 Sprinkler Wrench, well as with the applicable standards procedure P/N 56-000-6-387 of the National Fire Protection Asso- Specify: W-Type 7 Sprinkler Wrench, ciation (e.g., NFPA 25), in addition to Contact your local distributor for avail- P/N 56-850-4-001 the standards of any other authorities ability.When placing an order,indicate having jurisdiction.Contact the install- the full product name and Part Number ing contractor or product manufacturer (p/N). with any questions. Automatic sprinkler systems are rec- Sprinkler Assemblies with NPT ommended to be inspected, tested, Sread ConnectionsSeY or and maintained by a qualified Inspec- Specify: Series TY-FRB Upright.IN tion Service in accordance with local Pendent (specify)Quick Sprinkler,p SIN requirements and/or national codes. (specify), mea i Response, (specify) temperature rating, (specify) finish, P/N(specify,refer to Table A). TFP172 Page 4 of 4 SPRINKLER FINISH(See Note 7) K TYPE TEMPERATURE BULB LIQUID NATURAL CHROME POLYESTERe FACTOR COLOR BRASS PLATED 135°F(57°C) Orange UPRIGHT 155°F(68°C) Red (TY313) and 175°F(79°C) Yellow 1,2,3,4,5,6 PENDENT (TY323) 200°F(93°C) Green 5.6 286°F(141°C) Blue 1/2 in.NPT 135°F(57°C) Orange RECESSED 155°F(68°C) Red PENDENT 1,2,3,4 (TY323) 175°F(79°C) Yellow Figures 4°and 5b 200°F(93°C) Green Notes: 1. Listed by Underwriters Laboratories,Inc..(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. VdS Approved(For details,contact Johnson Controls,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-54-428-3377.) 6. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06)as Quick Response Sprinklers. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. a. Installed with Style 15(1/2 in.NPT)5/8 in.Total Adjustment Recessed Escutcheon,as applicable. b. Installed with Style 20(1/2 in.NPT)1/2 in.Total Adjustment Recessed Escutcheon,as applicable. c. Frame and Deflector only.Listings and approvals apply to color(Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS P/Na 77 — XXX — X — XXX SIN SPRINKLER TEMPERATURE FINISH RATINGS 370 5.6K UPRIGHT(1/2 in.NPT) TY313 1 NATURAL BRASS 135 135°F(57°C) 371 5.6K PENDENT(1/2 in.NPT) TY323 3 PURE WHITE(RAL9010)a 155 155°F(68°C) POLYESTER Notes: SIGNAL WHITE(RAL9003) a. Use suffix"I"for ISO 7-1 connection;for example. 4 POLYESTER 175 175°F(79°C) 77-370-4-175-I 5 JET BLACK(RAL9005) 200 200°F(93°C) POLYESTER 9 CHROME PLATED 286 286°F(141°C) Notes: a. Eastern Hemisphere sales only TABLE B SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION 1400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+1-215-362-0700 )'�� 0 2018 Johnson Controls.AU rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. Johnson NAI ZONAL FIRE PROTECTION AssOCIAI ION and NFPA are registered Trademarks of Naliunal Fire Protection Association: Controls TEFLON Ica registered Trademark of DuPont Controls •i Eddythread 40 A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of 1.0 Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: • Has a Corrosion Resistance Ratio of 1.0 • Has a Pressure Rating of 300 psi • Is Lighter Weight Than Schedule 40 • Is Approved by Factory Mutual and Listed by Underwriters Laboratories • Is Produced in Accordance to ASTM A-135 and A-795 • Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves • Is Produced From Steel With Excellent Properties of Strength and Threadability • Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* • Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS I.D. (r E rV 1 1.461 1.083 70 1 1/4 2.070 lf%' 1.418 ,IXitaMI, 51 1 1/2 2.547 % 1.654 1 44 2 3.308 2.123 30 CORROSION RESISTANCE RATIOS NOMMAL PIPE SIZE On) `' sctieDKE 40 .`EAD 1 % . 1.0Q ' 1.00 1 1/4 1.00 f4 1 1 1/2 %P4 100 ' .,* 1 ,d, �pyy 2 1.00 qd 1.Qb *Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems r ( r,Ty 1819 Clarkson Road For additional information, U Chesterfield,MO 63017 contact your salesperson today at c L us �W.& n BULL MOOSE TUBE COMPANY (800)325-4467 (800)325-4467 or(636)537-2600 LISTED FAX:(636)537-2645 in the USA,or from Canada www.bullmoosetube.com call(800)882-4666 A L A O company e-mail:sales@,bullmoosetube.com APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 CO® Worldwide www.tyco-fire.com Contacts Series RFII — 5.6 K-factor "Royal Flush II" Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage General The Series RFII Sprinklers are shipped with a Disposable Protective Cap.The Description Protective Cap is temporarily removed during installation and replaced to help w�. The TYCO Series RFII 5.6 K-factor, protect the sprinkler during ceiling _rt "Royalinstallation or finish.The tip of the Pro- prink Flush II" Concealed Pendent tective Cap can be used to mark the Ai! Sprinklers Quick Response (3-mm bulb) and Standard Response (5-mm center of the ceiling hole into plaster r bulb), are decorative s rinklers fea- board or ceiling tiles by gently pushing P turing a flat cover plate designed to the ceiling product against the Pro conceal the sprinkler.These sprinklers tective Cap. When ceiling installa are optimal for architecturally sensi tion is complete,the Protective Cap is tive areas such as hotel lobbies,office removed and the Cover Plate/Retainer buildings,churches,and restaurants. Assembly is installed. Each sprinkler includes a Cover Plate/ As an option,the Series RFII Standard Retainer Assembly and a Sprinkler/ Response(5 mm bulb)"Royal Flush II" Support Cup Assembly. The separa- Concealed Pendent Sprinklers can be ble, two-piece assembly design pro- fitted with a silicone Air and Dust Seal. Technical vides the following benefits: (Refer to Figure 5.) The Air and Dust Seal is intended for sensitive areas Data • Allows installation of the sprinklers where it is desirable to prevent air and and pressure testing of the fire pro- dust from the area above the ceiling to Sprinkler Approvals tection system prior to installation of pass through the cover plate. Approvals apply only to the service a suspended ceiling or application of conditions indicated in the Design Criteria the finish coating to a fixed ceiling. NOTICE section. • Permits the removal of suspended The Series RFII Concealed Pendent • TY3531 (3 mm Bulb)is UL Listed,C-UL ceiling panels for access to building Sprinklers described herein must be Listed and NYC Approved(MEA 353- service equipment without having installed and maintained in compliance 01-E)as Quick Response. to first shut down the fire protection with this document and with the appli- • TY3531 (3 mm Bulb)is VdS Approved system and remove sprinklers. cable standards of the NATIONAL FIRE (Certificate No.G4090007). • Provides for 1/2 in.(12,7 mm)of ver- PROTECTION ASSOCIATION(NFPA), •in addition to the standards of any TY3531 (3 mm Bulb)is FM and tical adjustment to allow a measure LPCB Approved(Ref.No.094a/10)as of flexibility in determining the length authorities having jurisdiction. Failure Standard Response. of fixed piping to cut for the sprinkler to do so may impair the performance drops. of these devices. concealed sprinklers ote:FM and LPCB�or quick o not prove The owner is responsible for maintain- response. ing their fire protection system and devices in proper operating condition. • TY3551 (5 mm Bulb)is UL Listed,C-UL The installing contractor or sprinkler Listed,FM Approved,LPCB Approved manufacturer should be contacted with (Ref.No.094a/9),and NYC Approved any questions. (MEA 353-01-E)as Standard Response. IMPORTANT Approvals for Air and Dust Seal Refer to Technical Data Sheet Sprinkler UL and C-UL Listed for use with the RFII TFP2300 for warnings pertaining to Standard Response Concealed Sprinkler regulatory and health information. Identification (TY3551) Always refer to Technical Data Maximum Working Pressure Sheet TFP700 for the "INSTALLER Number (SIN) Maximum 250 psi(17,3 bar)by UL, WARNING"that provides cautions C-UL,and NYC with respect to handling and instal- TY3531 — 3 mm bulb Maximum 175 psi(12,1 bar)by FM,VdS, lation of sprinkler systems and com- TY3551 — 5 mm bulb and LPCB ponents. Improper handling and Temperature Rating installation can permanently damage 155°F(68°C)Sprinkler with a sprinkler system or its compo- 139°F(59°C)Cover Plate nents and cause the sprinkler to fail to operate in a fire situation or cause 200°F(93°C)Sprinkler with it to operate prematurely. 165°F(74°C)Cover Plate Page 1 of 4 SEPTEMBER 2018 TFP181 TFP181 Page 2 of 4 • Discharge Coefficient 1/2"NPT 7 rSEALING K=5.6 GPM/psi1i2(80,6 LPM/bars/2) T ASSEMBLY Adjustment 1/2 inch(12,7 mm) , I \Finishes FRAME See the Ordering Procedure section. � ,..4- CAP / \ Physical Characteristics , Frame Bronze Support Cup Plated Steel SUPPORT Guide Pins Stainless Steel CUP WITH I BULB Deflector Bronze ROLL FORMED Compression Screw Brass THREADS Bulb Glass Cap Bronze or Copper i /--( R COMPRESSION Sealing Assembly..Beryllium Nickel w/TEFLON r/ \ I I Cover Plate Brass SCREW Retainer Brass GUIDE �/l) i _ /. Ejection Spring Stainless Steel PINS(2) % / Design , , �s DEFLECTOR Criteria (DROPPED DEFLECTOR i i i - ' POSITION) The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent SPRINKLER/SUPPORT CUP Sprinklers are intended for fire protec- ASSEMBLY tion systems designed in accordance I I with the standard installation rules THREAD INTO P I RETAINER recognized by the applicable Listing SUPPORT J I WITH THREAD or Approval agency; for example, UL CUP UNTIL \ O O I> DIMPLES Listing is based on NFPA 13 and VdS MOUNTING Approval is based on the CEA 4001. SURFACE IS EJECTION FLUSH WITH SPRING For more information on LPCB and VdS CEILING Approvals,contact Johnson Controlss at the following office: Enschede, Netherlands "J/ J l a -, Telephone:31-53-428-4444 / Fax:31-53-428-3377 SOLDER J COVER The Series RFII Concealed Pendent TABS(3) COVER PLATE/RETAINER PLATE Sprinklers are only listed and approved ASSEMBLY with the Series RFII Concealed Cover FIGURE 1 Plates having a factory applied finish. MODEL RFII CONCEALED SPRINKLER ASSEMBLY NOTICE Do not use the Series RFII in applica- Installation Do not attempt to compensate for tions where the air pressure above the insufficient adjustment in the Sprinkler ceiling is greater than that below.Down The TYCO Series RFII 5.6 K-factor, by under-or over-tightening the Sprin- drafts through the Sprinkler/Support "Royal Flush II" Concealed Pendent kler/Support Cup Assembly.Re-adjust Cup Assembly can delay sprinkler Sprinklers must be installed in accor- the position of the sprinkler fitting to operation in a fire situation. dance with this section. suit. General Instructions Step 1. Install the sprinkler only in the Operation Do not install any bulb-type sprinkler •pendent position with the center line if the bulb is cracked or there is a loss of the sprinkler perpendicular to the When exposed to heat from a fire, the mounting surface. Cover Plate, normally soldered to the of liquid from the bulb.With the sprin Ste 2. Remove the Protective Retainer at three points, falls away to kler held horizontally,a small air bubble p Cap. expose the Sprinkler/Support Cup should be present.The diameter of the Step 3. With pipe thread sealant Assembly. air bubble is approximately 1/16 inch applied to the pipe threads, hand- (1,6 mm)for the 155°F(68°C)and 3/32 tighten the sprinkler into the sprinkler The Deflector — supported by the inch(2,4 mm)for the 200°F(93°C)tern- fitting. Guide Pins — then drops down to its perature ratings. Step 4. Wrench-tighten the sprinkler operational position. A leak tight 1/2 inch NPT sprinkler using only the RFII Sprinkler Wrench. The glass bulb contains a fluid that joint should be obtained by applying a (Refer to Figure 3.) Apply the RFII expands when exposed to heat.When minimum to maximum torque of 7 to 14 Sprinkler Wrench to the Sprinkler as the rated temperature is reached, the ft.-lbs. (9,5 to 19,0 Nm). Higher levels shown in Figure 3. fluid expands sufficiently to shatter the of torque can distort the sprinkler Inlet glass bulb,activating the sprinkler and with consequent leakage or impairment allowing water to flow. of the sprinkler. TFP181 Page 3 of 4 ' FACE OF CLEARANCE HOLE CLEARANCE SPRINKLER DIAMETER HOLE FITTING „s, (. DIMENSION C J SPRINKLER cl �ME SUPPORT CUP 1 ASSEMBLY I 1 THREADED) D ADJUSTMENT k/ A pill ■ iv 1■1 FACE o -— — --- OF CEILING, RETAINING RING f� r ,"" A MOUNTING 1 SURFACE 4 ll FIGURE 4 \ IIV DISPOSABLE PROTECTIVE CAP ---f "—, ,�•' Step 5. Replace the Protective Cap I by pushing it upwards until it bottoms I J out against the Support (Refer =i 9 PP Cup. T 1 r to Figure 4.)The Protective Cap helps 3/16"to 11/16" MANUFACTURER DEFLECTOR COVER PLATE prevent damage to the Deflector and (4,8 to 17,5 mm) PRESET GAP IN DROPPED RETAINER Arms during ceiling installation and/or REFERENCE 3/32"(2,4 mm) POSITION ASSEMBLY finish.You can also use the Protective Cap to locate the center of the clear- COVER PLATE COVER PLATE ance hole by gently pushing the ceiling -PROFILE DEPTH DIAMETER material up against the center point of DIMENSION B DIMENSION A the Protective Cap. A:3-1/4 inches(82,6 mm) C:2-3/8 to 2-5/8 inches(60,3 to 66,7 mm) NOTICE B:3/16 inches(4,8 mm) D: 1-3/4 to 2-1/4 inches(44,5 to 57,2 mm) As long as the Protective Cap remains in place,the system is considered "Out FIGURE 2 of Service". SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS Step 6. After the ceiling has been completed with the 2-1/2 in.(63,5 mm) diameter clearance hole and in prep- - aration for installing the Cover Plate/ Retainer Assembly,remove and discard ij=l1 FRAME fuel,_ the Protective Cap. Verify that the I 'M ARM % r1i Deflector moves up and down freely. �: If the Sprinkler is damaged and the SUPPORT I _ �� Deflector does not move up and down freely, replace the entire Sprinkler. CUP C I - I Do not attempt to modify or repair a damaged sprinkler. I1I!iliiIII Step 7. When installing an Air and Dust Seal,refer to Figure 5;otherwise, -------- proceed to Step 8. To attach the Air 7/8"(23 mm) and Dust Seal, verify the angle of the SQUARE outside edge of the seal is oriented according to Figure 5.Start the edge of _ the Retainer in the grooved slot of the ALIGN �J � Air and Dust Seal and continue around ARROWS WITH / 1 1 \\ the retainer until the entire Air and Dust • FRAME ARMS i \_ Seal is engaged. Ii i 1 1 al ACCEPTS '"-i r�i • 0 1/2"SOCKET DRIVE FIGURE 3 RFII SPRINKLER WRENCH TFP181 Page 4 of 4 Step 8. Screw on the Cover Plate/ SUPPORT — SPRINKLER FACE OF ORIENT Retainer Assembly until the Retainer --- CUP --------- CEILING !—SEAL (shown in Figure 2)or the Air and Dust BEVEL AS Seal (shown in Figure 5) contacts the jam(` l j SHOWN . ceiling.Do not continue to screw on the M COVER Cover Plate/Retainer Assemblyso that PLATE 1 RETAINER it lifts a ceiling panel out of itnormal ` I 11.11 position. If you cannot engage the ASSEMBLY Cover Plate/Retainer Assembly with .'the Support Cup or you cannot engager,the Cover Plate/Retainer Assembly suf- ��� / AIR ficientl to contact the ceilin ou must reposition the Sprinkler Fittig. AP' '■'• ;,r. �� AND DUST I. ■ .Fa - SEAL _mis. LIP OF COVER • Care and RETAINER PLATE FIGURE 5 Maintenance OPTIONAL AIR AND DUST SEAL FOR SERIES RFII(TY3551) The TYCO Series RFII 5.6 K-factor, Care must be exercised to avoid "Royal Flush II" Concealed Pendentdamage to the sprinklers - before, Ordering Sprinklers must be maintained and during, and after installation. Sprin- serviced in accordance with this klers damaged by dropping, striking, Procedure section. wrench twist/slippage,or the like,must Before closing a fire protection system be replaced. Also, replace any sprin- Contact yourW local distributor for main control valve for maintenance kler that has a cracked bulb or that has availability. When placingt a an order, work on the fire protection system lost liquid from its bulb. (Ref. Installa- that indicate the full product name. it controls, obtain permission to tion Section.) Sprinkler/Support Cup Assembly shut down the affected fire protectionExercise care to avoid damage to sprin- Specify: Series RFII (specify SIN), system from the proper authoritiesklers before, during, and after instal- K=5.6,"Royal Flush II"Pendent Sprin- and notify all personnel who may be lation. Replace sprinklers damaged klers(specify)temperature rating,P/N* affected by this action. by dropping, striking, wrench twist- (specify): Absence of the Cover Plate/Retainer ing, wrench slipping, or the like.Also, 155°F(68°C) 200°F(93°C) Assembly can delay sprinkler opera- replace any sprinkler that has a cracked TY3531 51-792-1-155 51-792-1-200 tion in a fire situation. bulb or that has lost liquid from its bulb. TY3551 51-790-1-155 51-790-1-200 (Refer to the Installation section.) When properly installed, there is a • Use Suffix"I"for ISO 7-1 connection;for example, nominal 3/32 in. (2,4 mm) air gap If you must remove a sprinkler, do not 51-792-1-155-1 between the lip of the Cover Plate and reinstall it or a replacement without Separately Ordered Cover Plate/ the ceiling,as shown in Figure 2. reinstalling the Cover Plate/Retainer Retainer Assembly: Assembly. If a Cover Plate/Retainer rating from This air gap is necessary for proper Assembly becomes dislodged during below)Specify:S (temperaturees RFII Coverrm operation of the sprinkler.If the ceiling service,replace it immediately. Plateelowith ie(finish), Concealed(specify). requires repainting after sprinkler ( ) ( p y). The owner is responsible for the installation, ensure that the new paint inspection,testing,and maintenance of 139°F(59°C)(a) 165°F(74°C)(b) does not seal off any of the air gap. Grey White their fire protection system and devices (RAL9002) 56-792-0-135 56-792-0-165 Do not pull the Cover Plate relative to in compliance with this document, as Brass 56-792-1-135 56-792-1-165 the Enclosure.Separation may result. well as with the applicable standards Pure White(c) which are found to of the NATIONAL FIRE PROTECTION (RAL9010) 56-792-3-135 56-792-3-165 Sprinklersking exhibitingchvisible signs bef ASSOCIATION,for example, NFPA 25, Signal White leaking or must be replaced. in addition to the standards of any other (RAL9003) 56-792-4-135 56-792-4-165 authorities having jurisdiction.Contact Jet Black Automatic sprinklers must never be the installing contractor or sprinkler (RAL9005) 56-792-6-135 59-792-6-165 painted, plated, coated, or other- manufacturer regarding any questions. Brushed Chrome 56-792-8-135 56-792-8-165 wise altered after leaving the factory. Automatic sprinkler systems should be Chrome 56-792-9-135 56-792-9-165 Modified sprinklers must be replaced. inspected,tested,and maintained by a Custom 56-792-X-135 56-792-X-165 Sprinklers that have been exposed to qualified Inspection Service in accor- corrosive products of combustion, but dance with local requirements and/or (a) For use with 155°F(68°C)sprinklers. have not operated,should be replaced national code. (b) For use with 200°F(93°C)sprinklers. • if they cannot be completely cleaned (c) Eastern Hemisphere sales only. by wiping the sprinkler with a cloth or Limited Sprinkler Wrench by brushing it with a soft bristle brush. Specify: RFII Sprinkler Wrench, Warranty P/N 56-000-1-075 For warranty terms and conditions,visit Air and Dust Seal www.tyco-fire.com. Specify:Air and Dust Seal, P/N 56-908-1-001 1400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+1-215-362-0700 L / / 0 2018 Johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. Johnson ki/ NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; ro Contl e .7 TEFLON Is a registered trademark of DuPont 4.1 'i, " 1 r r sh ;,,,,.."`!","4"..,,..0.1",>,'..1....1r, !a 1 w +r /f/ �0 "a �. w"Y as , ,• * 4� ' w s ' r ;,G//,. Illilli s� 9 b * Mri * �� = IrIR "HWS a •fi'Y r / �"" . as. "� � < Ir ','?,,•'',,,,7,,,, ��, 115;iiiI, t 0,14 C }b w drff ,. i Y ," r� �. z ,w. a '-',..-,:-/•-':: s y b ^ k 4x ^ • Y..;'‘''',,,'...!.., 7' k C,Awai u ib �'tt,t�q: r,�'Y, 'y� � * ..'',..,14,4.4.."..;"^..,....:4;.,'' * re f r �i y 1 ,..;•..,-.0.4',...a...,..404.0 /".'.'"''''''''''''•'''''.4' ''''''''"W'''''''''''''''''''''.4vir.`' '''.....41.0.4,4.-..,4%. ,t'44...44.,...',..'t . ""'-''''. jz ,a Z ;'�, fir" '7 r v � aq µi } '...; „} i A �" , w �GSm'M,. � ' ,'jr', fJr+ .1... , /. IS t Y:� ,b a r. F. i 4 !//r� ! :,i yY. 1,......... „.,,,,o,,., fhb y® ° ' Sk44........,..t,...4:. ,,,,,"4'1...:'',....,4*,''''''', -.,.. .., , ., ,„' ' ::,,....;,,,,,...;,.. ,..r..,...,,, ,,,,,,,.....//,...,/,...,.,.2.......,,....:,......,...:,,",..,,i,:„.....2,,,,..,,,,,,,, , t t 4111.011 f r EiMilli ' " ':„ .:;y2,../'. = : rrr ' ! l r r ./ '"'",2//-', IL7Y SMITHCcoPE : :., ' ' INTERNATIONAL . ' Ductile Iron Threaded Fittings -.. . Specifications • 4$0. branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 WSP C0j/11US • Ductile iron castings conform to ASTM A536 LISTED • Fitting dimensions conform to ASME B16.3 44:°• Bushings and plugs conform to ASME B16.14 • Fittings are 100% air tested APPROVED • NPT threads on all fittings conform to ASME B1.20.1 • Independent lab verification that fittings meet applicable chemical &physical properties • Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Working , Degrees F 300# Class PressureThreadedNonshock Fittings 20 to 100 500 ; 150 �' 500 200 480 250 .. 460 300 440 350 420 400 400 450 380 i.,,_ tt s �' 500 360 550340 ,a :t„,-,,,,,,,,4----- 600 320 650 300 Tl4.L,.`„ -.-F, v im S• 3 i l;. :,,„, . P,- , i. Ductile Iron Fittings- Class 300 UL/FM 1tL4nm • c ® us APPROVED Fig. 35E 3-90°Elbow LISTED A , Size A Packing Weight Part Number in in Inner Master lb + 1/2 35E 3004 1.13 100 200 0.2 i i 3/4 35E 3006 1.31 70 140 0.3 A 1 350 3010 1.50 40 80 0.5 '■U; 1-1/4 35E 3012 1.75 25 50 0.8 - 1-1/2 35E 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3-90°Reducing Elbow B Size A B Packing Weight < > in Part Number in in Inner Master lb Lift3/4 x 1/2 35903006004 1.20 1.22 80 160 0.3 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 1 x 3/4 3590 3010006 1.38 1.45 50 100 0.4 j�i A 1-1/4 x 1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4 x 3/4 359E3012006 1.45 1.63 35 70 0.6 1-1/4 x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2x 1/2 350'03014004 1.52 1.75 30 60 0.6 1-1/2 x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 3590-3014010 1.65 1.80 20 40 0.8 1-1/2 x 1-114 35RE3014012 1.82 1.88 18 36 1.0 2x 1/2 350E3020004 1.60 1.97 18 36 1.0 2 x 3/4 35653020006 1.60 1.97 18 36 1.0 2 x 1 350E3020010 1.73 2.02 16 32 1.2 2 x 1-1/4 358E3020012 1.90 2.10 12 24 1.3 II 2 x 1-1/2 359E3020014 2.02 2.16 10 20 1.5 2-1/2 x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2 ! 2-1/2 x 2 35603024020 2.3.1 2.60 6 12 2.5 Fig. 35F 3-45°Elbow Size Part Number A Packing Weight �A in in Inner Master lb _ x j �, 1/2 351 3004 0.88 130 300 0.2 3/4 35F 3006 0.98 80 160 0.3 ,101\ 41 35F3010 1.13 40 80 0.5 1-1/4 35F 3012 1.29 25 50 0.7 -1/2 350 3014 1.44 20 40 0 ��i III� 2 350 320 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3- Tee Size A Packing Weight Part Number in in Inner Master lb till _If1/2 35T 3004 1.13 80 160 0.3 tI 3/4 351 3006 1.31:. ; 30 60 0.5 =�iI 1 35T 3010 1 50 25 50 0.7 1-1/4 3573012 1.75: - 10 20 1.1 '' i 1-1/2 357 3014 1,94 10 20 1.5 A A 2 3513020 2.25 6 12 2.4 2-1/2 35T 3024 2.70 4 8 4.3 111 S\,trill-COOPER INTERNATIONAL® • 'POLL FREE. 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com t ' � ; Ductile Iron Fittings- Class 300 UL/FM x • celus APPROVED Fig. 35RT3-Reducing Tee LISTED • Size A B C Packing Weight Part Number 101_ in in in in Inner Master lb 314 x 1/2 35RT3006004 1.20 1.20 1.22 60 120 0.4 i rik.0 1 x 1/235013010004 1.26 1.26 1.36 30600.6 1 (� i1 x 1/2 x 1 35013010004010 1.50 1.36 1.50 30 60 0.6 1 x 3(4 35013010006 1.38 1.38 1.45 25 50 0.6 < >< 1 x 3/4 x 3/4 35013010006006 1.38 1.31 1.45 35 70 0.6 B A 1 x 3/4 x 1 35013010006010 1.50 1.45 1.50 25 50 0.7 1-1/4 x 1/2 35013012004 1.34 1.34 1.53 20 40 0.8 1-1/4 x 1/2 x 1-1/4 35073012004012 1.75 1.53 1.75 25 50 0.9 1-1/4 x 3/4 35013012006 1.45 1.45 1.62 15 30 0.9 1-1/4 x 3/4 x 1-1/4 35813012006012 1.75 1.62 1.75 20 40 1.0 1-114 x 1 351313012010 1.58 1.58 1.67 15 30 1.0 1-1/4 x 1 x 1/2 35013012010004 1.34 1.26 1.53 25 50 0.7 1-1/4x 1 x 3/4 35013012010006 1.45 1,38 1,63 20 40 0.8 1-1/4 x 1 x 1 35013012010010 1.58 1.50 1.69 20 40 0.9 1-1/4 x 1 x 1-1/4 35013012010012 1.75 1.69 1.75 15 30 1.0 1-1/2 x 1/2 35R13014004 1.41 1.41 1=66 16 32 1.0 1-1/2 x1/2 x1-1/4 35013014004012 1.81 1.56 1.88 24 48 1.1 1-1/2 x 1/2 x 1-1/2 35RT3014004014 1.94 1,66 1.94 12 24 1.2 1-1/2 x 3/4 35013014006 1.52 1.52 1.75 16 32 1.1 1-1/2 x 3/4 x 1-1/4 35R13014006012 1.94 1.66 1.88 20 40 1.1 1-1/2 x 3/4 x 1-1/2 35013014006014 1.94 1.75 1.94 18 30 1.2 1-1/2 x 1 35813014010 1.65 1.65 1.80 12 24 1.2 1-1/2 x 1 x 1/2 35813014010004 1.44 1,25 1.69 20 40 0.8 1-1/2 x 1 x 3/4 35813014010006 1.50 1.44 1.75 16 32 0.9 1-1/2 x 1 x 1 35013014010010 1.65 1.50 1.80 16 32 1.0 1-1/2 x 1 x 1-1/4 35RT3014010012 1.82 1.67 1.88 12 24 1.2 1-1/2 x 1 x 1-1/2 3511301401(Doll 1.94 1.80 1.94 12 24 1.3 1-1/2 x 1-1/4 351313014012 1.82 1.82 1.88 12 24 1.4 1-1/2 x 1-1/4 x 1/2 35013014012004 1,41 1,34 1.66 16 32 0.9 1-1/2 x 1-1/4 x 3/4 35013014012006 1.52 1.45 1.75 16 32 1.0 1-1/2 x 1-1/4 x 1 35013014012010 1.65 1.58 1.80 16 32 1.1 1-1/2x 1-1/4x 1-1/4 35813014012012 1.82 1.75 1.88 14 28 1.3 1-1/2 x 1-1/4 x 1-1/2 351-313914012014 1.94 1 88 1.94 14 28 1/1 2 x 1/2 35013020004 1.49 1.49 1.88 10 20 1.5 2 x 3/4 359 3020006 1.60 1.60 1.97 10 20 1.6 2 x 1 3501'3020010 1,73 1,73 2.02 8 16 1.7 2 x 1 x 2 35813020010020 2.25 2.02 2.25 8 16 1.9 2 x 1-1/4 350113020012 1.90 1.90 2.10 8 16 1.9 2 x 1-1/4 x 2 35013020012020 2.25 2.10 2.25 8 16 2.0 2 x 1-1/2 35013020014 2.02 2.02 2.16 8 16 2.1 2 x 1-1/2 x 1/2 35073020014004 1.49 1.41 1.86 10 20 1.3 2 x 1-1/2 x 3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 2 x 1-1/2 x 1 35013020014010 1.73 1.65 2.02 8 16 1.5 2 x 1-1/2 x 1-1/4 35813020014012 1.90 1.82 2.10 8 16 1.7 2 x 1-1/2 x 1-1/2 35813020014014 2.02 1.94 2.16 8 16 1.8 Fig. 35BT3-Bull Head Tee I Size Part Number A B C Packing Weight 1 �1 I� in in in in Inner Master lb 3/4 x 1 35813006010 1.45 1.45 1,37 30 60 0.6 1 x 1-1/4 35E313010012 1.67 1.67 1.58 20 40 0.9 01111111115 � �� 1 x 1-1/2 35013010014 1.80 1.80 1.66 15 30 1.0 A l< B > 1-1/4 x 1 x 1-1/2 35BT3012010014 1.88 1.80 1.82 15 30 1.2 1-1/4x1-1/2 35013012014 1,88 1.88 1.82 15 30 1.3 1-1/4 x 2 35313012020 2.10 2.10 1.90 10 20 1.6 1-1/2 x 1-1/4 x 2 35013014012020 2.16 2.10 2.02 10 20 1.8 1-1(2 x 2 35B43014020 2.16 2.16 2.02 8 16 1.8 SNI l'1'11-COOPFR IN'l'I?RNAI'IONAI® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com 112 Ductile Iron Fittings- Class 300 UL/FM ..i ;= • c0us APPROVED A Fig. 35CP3 -Straight Coupling with Ribs LISTED Size Part Number A Packing Weight in in Inner Master lb II 1/4 3 iCP3004 1.38 200 400 0.1 3/4' 35CP3006 1.63 100 200 0.2 I 1 35CP3010 1,75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 35C83024 3.00 9 18 2.2 Fig. 35RC3 -Hex Reducing Coupling Size Part Number A Packing Weight 'Ni in in Inner Master lb ® A 1 x 1/2 35RC3010004 1.69 80 160 0,3 1 x3/4 35RC3010006 1.69 60 120 0.4 li 1-1/4 x 3/4 35R03012006 2.06 40 80 0.6 41 1 2 x 1 (not hex) 35RC3020010 2.81 20 40 1.0 Fig. 35HB3 -Hex Bushing Size A Packing Weight B in Part Number in Inner Master lb 1 x 1/? 35HB3010004 1.06 180 360 0.2 1 x 3/4 35HB3010006 1.06 180 360 0.1 I A 1-114 x 1 35HB3012010 1.19 90 180 0.2 i 1-1/2 x 1 35HB3014010 1.25 75 150 0.4' 1-1/2 x 1-1/A 351103014012 1.25 75 150 0.3 2 x 1 35HB3020010 1.38 40 80 0.6 1 2 x 1-1/4 351-1133020012 1.38 40 80 0.6 = 2 x 1-1/2 35HB3020014 1.38 40 80 0.6! Fig. 35SP3 -Square Head Plug Size Part Number A Packing Weight in in Inner Master lb ,, , larill IA 1/2 35583004 094 600 1200 0.07 3/4 35583006 1.12 350 700 0.1 1 i ii 1 35S 13010 1.25 200 400 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35583014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 Fig. 35U 3-Union with Brass Seat A Size A Packing Weight Part Number -1 in in Inner Master lb ' 1 351_1 3010 2.19 20 40 1.0 1-1(4 35U 3012 2.50 15 30 1.2 I� �� 2 35U 3014 2.62 10 70 1.7 . kits 2 35U 3020 3.12 6 12 2.4 113 SIV11'I'11-COOPER INTERNAT1ONAi® • TOIL FREE. 1-M00-766-0076 • FAX(333)890-4456 • www.smithcooper.com 4.4''''''' .. Ductile Iron Fittings- Class 300 UL/FM c ® uS APPROVED A A Fig. 35X 3- Cross LISTED • Size A Packing Weight Part Number in in 1.50 Inner Master i i 20 40lb JA 1 35X 3010 0.9 I I 1-1/4 35X 3012 1.75 12 24 1.4 1-1/2 35X 3014 1.94 8 16 1.8 JA 2 35X 3020 2.25 6 12 2.8 B B Fig. 35RX3-Reducing Cross H` Size A B Packing Weight . .• Part Number in in Inner Master lb 1 j IA in 1-1/4 x 1 356X3012010 1.67 1.58 15 30 1.2 1 1 ,, 1-1/2 x 1 35RX3014010 1.80 1.65 12 24 1.4 w A 2 x 1 35RX3020010 2.02 1.73 8 16 2.0 Fig. 35C 3- Cap 8 Size A Packing Weight Part Number In in Inner Master lb 1JA1/2 350 3004 0.87 300 600 0.1 ,, "�35C 3006 0.97 200 400 0.1 1 35C 3010 1.16 110 220 0.2ti* g 1VI4Es .. 350 3012 1.28 70 140 0.4 s. 1-1/2 35C 3014 1.33 50 100 0.5 ts 14` 350 3020 1.45 25 50 0.8 2-1/2 35C 3024 1-70 18 36 1.6 Fig. 35BC3-Beam Clamp Size A Packing Weight AII IIISizePart Number in Inner Master lb A 3/8 358C3003 0.75 100 200 0.3 NI Nil I 1/2 35B03004 0.75 80 160 0.5 Thisi 11118 Ell SV'r1'1'l l-(:()OPER IN'FRRNA'['IONA1,® • "T'OC.L, 1:121;E 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com 114 P§SA F,•, •• c SIL FM us [vdS) LPCB g . `� Outiet-T OSTEO ll 491a/27 SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 • The Style 922 Outlet-T provides a convenient method of incorporating 1/2,3/4,and 1715,20 and 25mm outlets for directly connecting sprinklers,drop nipples,sprigs,gauges,drains and other outlet products.Available for 11/4 through 76.1 mm/32 to 76.1 mm piping systems,Style 922 outlets are UL/ULC Listed,LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe.When tightened,the assembly compresses the gasket onto the OD of the pipe.The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard,lightwall,Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing:Ductile iron conforming to ASTM A-536,grade 65-45-12.Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. Gasket: • Grade"E"EPDM-Type A (Violet color code).FireLock products have been Listed by Underwriters Laboratories Inc.and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services up to the rated working pressure using the Grade"E"Type A Gasket System. Bolts/Nuts:Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: • Orange enamel(North America, Latin America,Asia Pacific) • Red enamel(Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com ictauhic VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. - REV G 10.52 1 IPS CARBON STEEL PIPE- HOLE CUT PRODUCTS 10.52 STYLE 922 DIMENSIONS Nominal Size Hole Approx. inches/mm Diameter Dimensions-inches/millimeters Weight Each Run'1C Branch +0.06/+1.5 Y Z .:,FPT'F -0..00/.0.0 P V W lbs/kg.. _ 1% r/ 1 3/16 130 1.83 1 10 3.87 2.56 1.0 V ^� I 32 X 15 30.2 33.0 46.5 27.9 98.3 65.0 0.45 ,410 3 1 3/16 1.28 1.83 1.10 3.87 2.56 1.1 1 . 1 , 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 �.r W 1 ( 1 1 3/16 1.52 2.18 1.10 3.87 2.56 1 2... ___. (V;) 25 30.2 38.6 55.4 279 983 65.0 0.54 155Y I 13/16 1.42 195 1.22 4.08 2.56 1.2 40 X 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 3 13/16 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 356 49.5 31.0 1036 65.0 0.54 1 13/16 1.64 2.30 1.22 4.08 2.56 1.3 25 i 30.2 41.7 58.4 31.0 103.6 65.0 0.59 2 13/16 166 2.19 1.46 4.60...... 2.56 1.3 50 X 15 30.2 42.2 55.6 371 1168 65.0 0.59 �4 3 I 13/16 1.64 2.19 1.46 4.60 2.56 1.4 20 i 30.2 41.7 55.6 37.1 116.8 65.0 0.64 1 13/16 1.88 2.54 1.46 4.60 2.56 15 25 I 30.2 47.8 64.5 37.1 r 116.8 65.0 0.68 21/21/213/16 1.91 2.44 1.71 5.40 2.56 1.6 65 X 15 30.2 48.5 620 43.4 1312 65.0 0.73 3/4 j 1 3/16 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 480 62.0 43.4 137.2 650 0.73 1 13/16 2.13 2.79 1.71 5.40 2.56 1.6 25 30.2 54.1 709 434 137.2 65.0 0.73 76.1 mm X 'h r 13/16 1.91 2.44 - 171 5.50 2.56 1.6 15 30.2 48.5 62.0 43.4 139.7 650 0.73 3/4 1 3/16 1.89 2.44 1.71 5.50 2.56 1.6 20 130 2 48.0 62.0 43.4 139.7 65.0 0.73 1 13/16 2.13 2.79 1.71 5.50 2.56...._ 17. 25 I 30.2 541 70.9 43.4 139.7 - 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT(optional) male pipe threads only.Use of male threaded products with special features,such as probes,dry pen- dent sprinklers,etc.,should be verified as suitable for use with this Victaulic product.Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads(dimensions are approximate). www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICitauIl�i 10.52....2 REV G IPS CARBON STEEL PIPE-HOLE CUT PRODUCTS 10.52 r: leek® STYLE 922 PERFORMANCE Equivalent Length of 1 inch Schedule 40 Steel Pipe(per UL Run Size x Outlet Size 213.Section 16)(C=120)".FT es/rumX 1T: T 2X 1 2• 1 85 50 X 25 2.6 .._ 21/2 X 1 $.5 65 25 2.6 76.1 mm X 1 8.5 25 2.6 *Hazen-Williams coefficient of friction is 120 www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. •Ctaulle REV_G 10.52_3 STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing.Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 10.52 3355 REV G UPDATED 12/2009 ✓CtauIIC VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10.52 Pipe Hangers Fig.200- "Trimline" Adjustable Band Hanger (B-Line Fig.B317ONF) ' ' ca- Fig. 200F- "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig.B317ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC) c us LISTED Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm)thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications . Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. i !� Features: • (1/2" (15mm)thru 2" (5omm)) Flared edges ease installation for all pipe (�,� types and protect CPVC plastic pipe from abrasion. Captured design \ I,'I 1 keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. tt„ a / For hanger with non-captured nut order Fig.200S. • (21/2" (65mm)thru 8" 200mml Spring tension, on nut holds it securely in hanger before installation. Adjusting nut is easily removed. 1,4 / Approvals: Underwriters Laboratories listed (1/2" (15mm)thru 8" (200mm)) ' a Fig.200-1/2.200-/4 in the USA(UL) and Canada (cUL)for steel and CPVC plastic pipe and / Factory Mutual Engineering Approved (FM) (3/4" (20mm)thru 8" (200mm)). Fig.200-1 to 200-2 Fig.200-2Vzto200-8 Conforms to Federal Specifications WW-H-171 E &A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 &SP-58, Type 10. Maximum Temperature: 650°F(343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts s in place of a knurl nut. Order By: Figure number and pipe size , Designed to meet or exceed requirements of FM DS 2-0. r._ ,:. Fig.200 te Fig.200C Fig.200F Pipe Size Rod Size A B Approx.Wt./100 Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) 200-1/2 s x;,112" (15) ',` w, 3/8"-16 7::: .-..,.-.-...,:-- 31/8" (79.4) 25/8' (66.7) ', ' ,. t, 1'( (5.0) r 200-3/4 3/4' (20) 3/8"-16 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200-1 1" (251 3/8"-16 33/e (85.7) 25/8" (66.7) 112 12 (5.5) 200-11/4 11/4" (32) 3/8"-16 33/4" (94.0) 27/8' (73.0) 13 (5.9) i' 200-11/2 T 11/2" (40) 3/8"-16 37/8" (98.4) 1,' x27/8" (73.0) 41. 14 (6.4) 200-2 2' (50) 3/8"-16 41/2" (114.3) 3" (76.3) 15 16.9) 200-21/2 21/2" (65) r„ 3/8"-16 55/8" (142.9) 1.111 41/8" (104714; 27 (12.3) ,,..,. 200-3 3" (75) 3/8-16 57/8' (149.1) 4" (101.6) 29 (13.3) , Fig.200S 200-31/2 31/2" (90) 3/8"-16 .73/8" (187.3) 51/4" (133.3) ,;: 34 (15.6) . 200-4 4'' (100) 3/8'-16 73/8" (187.3) 5" (127.0) j 4 j 35 (16.0) 200-5 5" (125) 1/2 13 91/8" (231.81 61/4" (158.71' 11,. .,.:. 66 (30.2) 200-6 6" 1150) 1/2"-13 101/8" (257.2) 63/4" (171.4) 73 (33.4) 200-8 8" (200) 1/2"-13 131/8" (333.4) 83/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B- Line Protection Solutions 21 by .. Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig. 103) B3205L - Threaded Rod (right& left hand threads) TL Size Range: 3/8"-16 thru 3"-4 rod Specify Length .1 Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. - . TL Rod is threaded on both ends with right hand threads of the length shown.Also 1�� A available with left and right hand threads-specify Fig. B3205L when ordering. Thread Size Maximum Temperature: 750°F(399°C) Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number, rod size, length and finish Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) 83205-3/8 x'L' 3/8"-16 21/2" (63.5) 730 (3.25) 572 (2.54) - -- - -- --- ----- B3205-1/2 X1 1/2"-13 21/2" (63.5) 1350 (6.00) 1057 (4.70) B3205-5/8 x'L' '= 5/8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) 83205-3/4 x'L' ;. 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) B3205-7/8 x'L' . 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) B3205-1 x'L' 1"-8 4" (101.6) _ 5900 (26.24) 4620 (20.55) B3205-11/8 x'L'., 4 11/8"-7 41/2" (114.3) 7450 (33.14) 5830 (25.93) B3205-11/4 x'L' 11/4"-7 5" (127.0) 9500 (42.25) 7440 (33.09) 63205-11/2 x'L' 11/2"-6 6" (152.4) 13800 (61.38) 10807 (48.07) 83205-13/4 x'L' 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64.79) B3205-2 x'L' 2"-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) B3205-21/4 x11.' ` 21/4"-41/2 9" (228.6) 32300 (143.67) 25295 (112.51) B3205-21/2x'L' 21/2"-4 10" (254.0) 39800 (177.03) 31169 (138.64) 03205-23/4X'L' - 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08)' B3205-3 x'L' _r 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR - All Threaded Rod 120" (3.05m) Lengths (TOLCO Fig.100) Fig. 99 - All Threaded Rod Cut To Length \ ;, Ate' a Size Range: 3/8"-16 thru 11/2"-6 rod in 120"(3.05m)lengths or cut to length Material: SteelN -0d Maximum Temperature: 750°F(399°C) a a Finish: Plain. Contact B-Line for alternative finishes and materials. = s 0 Order By: Part number, rod diameter and finish �`0 Part No.-Size x Length Threads Recommended Load Approx.Wt./100 Ft. ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) ATR 1/4,,,--.X1.20- 99-1/4"x ength: 20 240 (1.07) 12 (5.44) -,ATR 3/01 ['20 99-3/a"x'len th ; 16 730 (3.24) 29 (13.15) �ATR1/2" t 120 99-1/2",-A length13 1350 (6.00) 53 (24.04) ATR 5/8"x 120 99-/8"xr llength ( 11 2160 (9.60) 89 (40.37) ATR 3/4"x 120 99-3/'4'Clength 10 3230 (14.37) 123 (55.79) ATR 2/8"x 120 99- length< 9 4480 (19.93) 170` (77.11) ATR 1"x 120 99-1'x lengthi 8 5900 (26.24) 225 (102.06) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Pipe Hangers&Supports 236 Nevised4/28/2014 by Efr•N VERTICAL MOUNT SAMMYS® SAMMYS° for Wood ,)St uis lc l l }ir;o t 0IGr7 ofwood structures Slly`anofCttU ,y w . Not less than Wood Flooring " ii 2"nominal width Product Features (1-1/2") 1- z •No pre-drilling required. Not less than thickness(2-1/2") •Quick to install using the Sammy 3"nominal zi Nut Driver with an 18V cordless (depth or side Wood Joist drill/driver. of vertical member) •Saves time from traditional Double Sheetrock methods. For vertical use- Ceiling install in center of lower tate. •Reduces installation cost. Minimum 2"embedment into base material for NFPA 13 compliancy = Compos1te t Truss •Made in the U.S.A. '* Consult truss manufacturer for recommended installation point i ix .g *Pee-drilling maybe required for.SST ..... z 25.380.Tool available an page 10. 'a Approvals Msdet Screw Ultimate FM Test Box Case Des Pullout(lbs) L Load(lbs) Qty Qty 210 (7/16"05B) 1/4" 8002957 GST 100 1/4 x 1" 25 125 670 (3/4'Ply) - F; 1/4" 8003957 GST 200 1/4 x 2" 1760 (Fir) 25 125 1/4" 8004957 GST 300 1/4 x 3" 2060 (Fir) 25 125 3/8" 8006957 GST.75 1/4 x 3/4" 564 (3/4'Ply) 25 125 la OSB) 3/8" 8007957 GST 10 1/4 x 1" 210 (7/16' 300 25 125 670(3/4"Ply) _. _ 3/8" 8008957 GST 20 1/4 x 2" 1760 (Fir) 850 1475 25 125 t/ ' 3/8" 8068925 GST 20-SS 1/4 x 2" 1760 (Fr) 850 ::::1:-...,:::: 25 125 6. 3/8" 8009925 GST 25-380 3/8 x 2-1/2' 2113 (Fir) 1500 25 125 3/8" 8010957 GST 30 1/4 x 3" 2060 (Fir) '. 1500 * 25 125 #14 Bla er 3/8" 8069925 GST 30-SS 1/4 x 3" 2060 (Fir) 25 125 Part#8113910 3/8" 8011925 GST 40 1/4 x 4" 2180 (Fir) `' 25 125 3/8" 8012925 GST 60 1/4 x 6" 2230 (Fir) 25 125 1/2" 8013925 GST 2 1/4 x 2" 1760 (Fir) '; J. 25 = 125 1/2 8014925 GST 2.5-380 3/8 x 2-1/2' 2113 (Fir) 25 125 iii,.. ,y ''1/2" 8015925 GST 3 1/4 x 3" 2275(Fir) -: < ( 25 125 1/2" 8016925 GST4 1/4x4" 2180 (Fir) 25 125 . , '.1/T' 8017925 GST 6 1/4 x 6" 2230(Fr) 25 125 #14 SW Red ii,iiifii:ii:' Nut Driver Part#8114910 SAMMY Swivel Head')for Wood :i---� ..: ,� , t;-- i'' �c'�� r, ct''''u Product Features •Eliminates distortion of threaded rod. •Saves time from traditional methods. •Accommodates up to 3 1/2'x 12 pitch roof. •Reduces installation cost. •Allows 17°deflection from vertical. •Made in the U.S.A. Rod Part Screw Ultimate .0:-1,VITost FM Test Min Box Case Approvals Model Size Number Descriptions Pullout(lbs) ) Load(tbs) Thickness _ Qty i 0>4 3/8" 8139957 SFI-GST 24 1/4x2" 1257(Fir) " 1050 1475 25 125 125 .0 3/8" 8141957 SH-GST 30 1/4 x 3" 1720(Fir) 1500 1475 25 125 #14 Black Nut Driver i. SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into Part#8113910 contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. For the most up to date information,visit www.sammysuperscrew.com 4 0 V u \fir