Report M'c '"\ 11aF-, acs ''\vd. , Ca rrie 33ZC-13SB RECEIVED JAN 1 b 2019 CITY OF _TIGARD 3UILDING DIVISION ROUND ZONE DAMPERS WITH VVT® ZONE CONTROLLER 3VTM CONTROL SYSTEM PART NO.: 33ZCDRO6ZC-01 , 33ZCDRO8ZC-01 , 33ZCDR1 OZC-01 , 33ZCDR12ZC-01 , 33ZCDR14ZC-01 , 33ZCDR16ZC-01 PERFORMANCE DATA PHYSICAL DIMENSION PRINT ©Copyright 2004 Carrier Corporation•Syracuse,New York 13221 Form 33ZC-13SB Replaces:New Printed in U.S.A. 105 9-04 Catalog No.513-368 Date: Supersedes: ROUND ZONE DAMPERS 33ZC Rev: WITH VVT®ZONE CONTROLLER -13SB JOB NAME: LOCATION: BUYER: BUYER P.O.# CARRIER# UNIT NUMBER: MODEL NUMBER: PERFORMANCE DATA CERTIFIED BY: DATE: DESCRIPTION The VVT round zone damper with VVT Zone Controller is a component of Carrier's 3VTM control system and provides accurate and precise airflow for VVT applications.The factory-integrated VVT zone controller main- tains space temperature by modulating the amount of supply airflow through its damper.The VVT zone controller operates on the 3V control system network and is compatible with all Carrier communicating devices PART DUCT DIAMETER WEIGHT CFM AIRFLOW RANGE NUMBER (in.) (Ib) Min Max 33ZCDRO6ZC-01 6 7.0 160 240 33ZCDRO8ZC-01 8 9.0 280 420 33ZCDR1 OZC-01 10 10.5 440 660 33ZCDR12ZC-01 12 14.0 630 950 33ZCDR14ZC-01 14 16.0 850 1175 33ZCDR16ZC-01 16 17.5 1125 1275 PERFORMANCE DATA Physical Characteristics • Dedicated maintenance table for system wide air balancing. Spiral Metal Duct Housing 24 Ga. • Capable of Proportional Integral Derivative(PID)control Elliptical Damper Blade 20 Ga. • Optional terminal fan or auxiliary heat control NOTE:Terminal fan or auxiliary heat control requires the VVT Zone -* Electrical Characteristics Controller Option Board P/N 33ZCOPTBRD-01 Input Volts 40 va at 24 vac±10%(50/60 Hz) • Remote occupancy contact input for a field supplied occupancy The power requirement sizing allows for accessory water valves and sensor for the fan contactor.Water valves are limited to 15 va.The fan con- • Global set point and occupancy scheduling tactor is limited to 10 va(holding). • Output Power 0 to 10 vdc for linked dampers Sensor averaging • VVT control for terminals up to 2.7 sq.ft inlet Environmental Requirements • Up to 32 Zone Controllers per system,maximum of 8 linkage Operating Temperature 32 F to 131 F(0°C to 55 C) coordinators or a total of 128 devices per single bus Storage Temperature 32 F to 158 F(0°C to 70 C) • Actuator preassembled to housing and rated at 35 in.-lb Operating Humidity 10%to 95%non-condensing (3.95 N-m)torque, an adjustable 45, 60, or 90-degree stroke, and provides 90-second nominal timing at 60 Hz Storage Humidity 10%to 41%at 158 F condensing • Control complies with ASHRAE 62.1 Agency Approvals -* Damper Control Capabilities • NEC Class 2 • Integral Supply Air Temperature Sensor • UL 916-PAZX and UL 873 • DCV-(Demand-Control–Ventilation)Sensor Input Point • Conforms to requirements per European Consortium standards • Counterclockwise and Clockwise Damper Rotation EN50081-1 (CISPR 22,Class B) and EN50082-1 (IEC 801-2, IEC 801-3,and IEC 801-4)for CE mark labeling • Configurable Minimum and Maximum Open Damper Positions • UL94-5V(actuator) • Link up to Four Dampers via 0 to 10 vdc signal Communications Characteristics Operating Performance Local communications between Carrier communicating network Torque Rating 35 in.lb devices at up to 38.4 KB.Computer access available. Degree of Rotation 45,60,or 90° Remote access through modem at up to 38.4 KB. Computer access Pressure Rating 1 in.wg static pressure available. Wiring Requirements -3 Zone Controller Capabilities Communication Bus—3-Conductor,18-Gage,Stranded,with Shield • Provides pressure dependent(VVT)control Power—2-Conductor,18-Gage,Stranded,with Shield • Demand Controlled Ventilation with field installed CO2 sensor. • Capable of stand-alone operation with supply-air temperature sensor. 2 105 1 ' PHYSICAL DIMENSION PRINT DIMENSIONS(Inches) PART NUMBER A B 1 I 33ZCDR06ZC-01 6 18 9.0 33ZCDR08ZC-01 8 18 11.0 33ZCDR10ZC-01 10 18 13.0 B 33ZCDR12ZC-01 12 24 15.0 1 C A 33ZCDR14ZC-01 14 24 17.0 33ZCDR16ZC-01 16 24 19.0 1 i W I z 1 ' J I a 1 O � I 0 Z 1 it � 1 Q 1 � 1 i U 1 1 i 1 I 1 ' 1 I! II 1 I W 1 Z 1 � J 1 o 1 W p 0 0 z 1 O 1 Q 1 I- 1 U 1 i ` 1 . I 3 Product VVTO Zone Controller Specification 3VTM Control System ,Carrier 33ZC Part Number: 33ZCVVTZC-01 3 The VVT Zone Controller is a compo- nent of Carrier's 3V Control System and is used to provide zone level tempera- ture and air quality control for Variable Volume and Temperature Applications. The VVT zone controller can be operat- ed and configured through the Carrier communicating network with the System Pilot user interface. The VVT Zone Controller provides the following features and benefits: • provides pressure dependent(VVT) control • uses Proportional Integral Derivative (PID) control • mounts directly onto VVT terminal damper shaft 1 • optional terminal fan control �,o��o \�� w��] ��% _ ��24VA�f IAQ/RH+24V NOTE:Terminal fan control requires the �" � VVT Zone Controller Option Board 0 _ C E - HEAT 24VAC GND GND "` P/N 33ZCOPTBRD-01 �y •� �Carrir,/. ,HEAT.,AND SAT D :43J ' H AT1 AND 24VA• PAT T56 • optional auxiliary heating control of: Y -.Z VVT fO 24VA' ND REMOTE '. two-position hot water; one, two, or IONEConbo/%i -i, " three-stage electric; modulating hot ,//,,,�J6 = , o water valve; or combination radiant/ eae;mme,ee 'aa C Part Number:33ZCVVTZC-01 ducted heat stages oto,oaAA,EAa m S/N: ao (4 Nm) `© Rax: NOTE:Auxiliary heating requires the -110s SIM' Element#:- JSo VVT Zone Controller Option Board 24 VAC/C Min or 1 2"t6: 1�o-0clu4C 8 M —; Camel- • 128 controller maximum system (must be located on • dedicated port for System Pilot connection same network bus segment) • can drive up to 4 linked damper actuators • up to 32 zone controllers per system • capable of local set point adjustment using field- • capable of zone humidity monitoring with field-installed installed temperature sensor(with temperature offset) humidity sensor • both controller housing and actuator are UL94-5V • Carrier Linkage System capability plenum rated • global set point and occupancy scheduling • control complies with ASHRAE 62.1 • sensor averaging • foreign language support for ASCII based character set Features/Benefits Flexibility for every application User interface The VVT®zone controller is a single duct,variable volume The VVT zone controller is designed to allow a service per- and temperature terminal control with a factory-integrated son or building owner to configure and operate the unit controller and actuator.The VVT zone controller maintains through the System Pilot user interface. A user interface is precise temperature control in the space by regulating the not required for day-to-day operation. All maintenance, flow of conditioned air into the space. configuration, setup, and diagnostic information is avail- Buildings with diverse loading conditions can be sup- able through the Level II communications port to allow ported by controlling reheat (single duct only) or supple- data access by an attached computer running Network Ser- mental heat. The VVT zone controller can support vice Tool or ComfortVIEWTM software. two-position hot water, modulating hot water, 3-stage elec- Functions tric heat,or combination baseboard and ducted heat. • Pressure dependent space temperature control for sin- -* Carrier linkage system compatibility gle duct, series fan powered and parallel fan powered When linked to a Carrier Linkage System, the VVT zone air terminals controller provides numerous features and benefits such as • Auxiliary heat functions including two-position hot weighted average demand for system operation, reference water valve, 3 stages of electric heat, modulating hot zone temperature-and set points, set point averaging, glo- water valve and combination radiant/ducted heat stages bal set point schedule,and occupancy scheduling. • T55/T56 wall mounted space temperature sensor interface Additional control features • T56 space temperature set point reset (slide The VVT zone controller provides additional control fea- potentiometer) tures such as Occupied/Unoccupied scheduling initialized • Timed override (T55/T56 pushbutton)with one-minute via the network. The zone controller offers override granularity invoked from a wall sensor during unoccupied hours from • Space temperature and set point reset sharing 1 to 1440 minutes in 1-minute increments. Optional CO2 • Display of relative humidity based on local or remote control or relative humidity monitoring are also available. sensor • Local occupancy control Simple actuator connection Remote occupancy override The VVT zone controller control assembly contains an • Airside linkage integral VVT actuator assembly that is field mounted to the • Linkage function for multiple terminals with and without terminal damper shaft, similar to the mounting of a stan- an air source dard actuator. The actuator is rated at 35 lb.-in. (3.95 N-m) • Adaptive optimal start(AOS) torque, a 90-degree stroke, and provides 90-second nomi- • Sensor grouping function nal timing at 60 Hz. The actuator is suitable for mounting • Commissioning functions onto a 3/8-in. (9.5 mm) square or round VVT box damper • System-wide air balancing shaft, or onto a 1/2-in. (13 mm) round damper shaft. • Damper calibration The minimum VVT box damper shaft length is 13/4-in. • Sensor trim (45 mm). The VVT zone controller is designed for vertical • Carrier network tables and alarms or horizontal mounting. • Demand Controlled Ventilation(DCV) Ease of installation • Analog CO2 monitoring and control • Loadshed/redline response The VVT zone controller is provided with removable con- • System Pilot interface nectors for power, communications, and damper. The VVT zone controller has non-removable screw type con- nectors for inputs. The VVT zone controller also provides an RJ-14 modular phone jack for the Carrier network software connection to the module via Carrier network communications. 2 105 Specifications ca,.,.ie,, Wiring connections Communications . Field wiring is 18 to 22 AWG (American Wire Gage). The The number of controllers is limited to 128 devices maxi- WT zone controller is a NEC (National Electronic Code) mum, with a limit of 8 systems(Linkage Coordinator con- Class 2 rated device. figured for at least 2 zones). Bus length may not exceed Inputs 4000 ft (1219 m), with no more than 60 devices on any 1000 ft(305 m)section. Optically isolated RS-485 repeat- • Space temperature sensor ers are required every 1000 ft(305 m). • T55/T56 wall-mounted space temperature sensor At 19,200 and 38,400 baud, the number of controllers interface is limited to 128 maximum,with no limit on the number of • T56 space temperature set point reset(slide potentiom Linkage Coordinators. Bus length may not exceed 1000 ft eter) (305 m). • Optional supply air temperature sensor (required for reheat and stand-alone operation) Environmental ratings • Optional primary air temperature sensor (one required Operating Temperature 32 F to 131 F(0°C to 55 C) per system that does not utilize a linkage compatible air Storage Temperature 32 F to 158 F(0°C to 70 C) source) • Optional CO2 sensor Operating Humidity 10%to 95%,non-condensing • Optional relative humidity sensor(for monitoring only) Storage Humidity 10%to 41%at 158 F,condensing • Optional remote occupancy contact input Power consumption Outputs The power requirement sizing allows for accessory water • Integrated factory-wired pressure dependent damper valves and for the fan contactor.Water valves are limited to actuator 15 va.The fan contactor is limited to 10 va(holding). • Heating (requires VVT Zone Controller Option Board Vibration 33ZCOPTBRD-01) Performance Vibration: — Two-position hot water — One to three stages of heat 1.5 G measured at 20 to 300 Hz — Modulating hot water valve Corrosion — Combination radiant/ducted heat stages Office environment. Indoor use only. • Terminal fan (requires WT Zone Controller Option Board 33ZCOPTBRD-01) Approvals • Damper position output(0 to 10v)for linked dampers • NEC Class 2 Power supply • UL 916-PAZX and UL 873 Conforms to requirements per European Consortium The power supply is 24 vac± 10%at 40 va(50/60 Hz). standards EN50081-1 (CISPR 22, Class B) and EN50082-1 (IEC 801-2, IEC 801-3, and IEC 801-4) for CE mark labeling • UL94-5V(actuator) Accessories Supply air temperature sensor —The 33ZCSENSAT (-40 to 118 C) and includes a 6-in. stainless steel probe supply air temperature sensor is required for heating appli- with conduit box. cations or stand-alone operation. The sensor has an oper- Space temperature sensor with override button — ating range of–40 to 245 F(-40 to 118 C)and includes a The 33ZCT55SPT Space Temperature Sensor with Over- 6-in. stainless steel probe and cable. ride Button is required for all applications. The space tem- Duct air temperature sensor — The 33ZCSENDAT perature sensor monitors room temperature, which is used Duct Air Temperature Sensor is required for cooling only by the Zone Controller to determine the amount of condi- applications on non-33ZC dampers. The sensor is used for tioned air that is allowed into the space. supply air monitoring. The sensor has an operating range Space temperature sensor with override button of–40 to 245 F (-40 to 118 C) and includes a mounting and set point adjustment— The 33ZCT56SPT Space grommet and 75-in. cable. Temperature Sensor with Override Button and Set Point Primary air temperature sensor—The 33ZCSENPAT Adjustment can be used in place of the 33ZCT55SPT Primary Air Temperature sensor is required on a linkage space temperature sensor if local set point adjustment is coordinator Zone Controller if the Zone Controller is not required. A space temperature sensor is required for all using a Carrier network, linkage compatible air source. applications. The space temperature sensor monitors The sensor is used to monitor the equipment's supply-air room temperature,which is used by the Zone Controller to temperature. The temperature is broadcast to the system determine the amount of conditioned air that is allowed Zone Controllers which receive information from the mas- into the space.The set point adjustment bar is configurable ter. The sensor has an operating range of –40 to 245 F 3 Accessories (cont) Hca,.,i�, for up to a ± 15 F (8 C) temperature adjustment by the 33ZCT55CO2 CO2 sensor is a combination CO2 sensor room occupant. and temperature sensor with pushbutton timed override. . Space temperature sensor with override button, The 33ZCT56CO2 has these features and includes a set set point adjustment, and liquid crystal display point offset slidebar. (LCD) — The 33ZCT59SPT space temperature sensor NOTE: The Relative Humidity sensor and Indoor Air with override button, set point adjustment, and LCD can Quality (CO2) sensor cannot be used on the same zone be used in place of the 33ZCT56SPT space temperature controller. sensor if an LCD is required. A space temperature sensor WT® zone controller option board is required for all applications. (33ZCOPTBRD-01) — The 3V-VVT Zone Controller Relative humidity sensor — The 33ZCSENSRH-01 Option Board is required for use of auxiliary heat and fan Relative Humidity sensor (indoor space) is required for control functions. The Option Board is field installed zone humidity monitoring. and provides four triac discrete outputs, three for supple- Indoor air quality sensor — Two CO2 sensors are mental heat and one for the fan output. available for optional Demand Controlled Ventilation (DCV). They are indoor, wall-mounted sensors. The Dimensions - ZONE CONTROLLER 2.36'(60 mm) itt 1 i 4 \'" / iFAN +24V \ c ss .'24VACIAND HEAT3 GND SPT „„F_-- 24VAC GND GND O`�O• �HEAT2� SAT yA' Cnt rler 24VAC PAT HEAT1 GND T56 6 I tO 24VAC GND VVT' REMOTE -—•N ZONE Controller " 1 4.84" (123 mm) I Carr lc�A + + O O' Assembled in USA Manual�� Part Number:33ZCVVTZC-01 ¢c7 N , I by Belimo for CARRIER erride , O CR SM: °' EN m> 35eoin-Ibas(4 Nm) ©Imml®© BUS#: Q _.nElement#: J5,,, a h O 2 124VAC/CC r I Unita: >°- o 17T>,' ¢ + 50/60 Hz 00Frg2�Z 3VA 2W CO ry 1^ 1 UUU+O'UQC7 8 U Ibl re w — — -- — _ --- — -- 4 9.2" Ill (234 mm) . Carrier • Carrier Corporation•Syracuse,New York 13221 105 9-04 A United Technologies Company Manufacturer reserves the right to discontinue,or change at any time,specifications or designs without notice and without incurring obligations. Book 1 4 New Book 1 Pg 4 Catalog No.523-351 Printed in U.S.A. PC 111 Form 33ZC-12PS Tab 11a 13a I Tall Replaces:New