PFI2018-00345 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT COMMUNITY DEVELOPMENT Permit#: PF12018-00345 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 12/18/2018 Parcel: SEG2019 Jurisdiction: Tigard Site address: Subdivision: Lot: Project: PGE Project Description: Adjacent to 8978 SW Reiling St. Replace and repair underground facilities. PGE job M2495695. Owner: FEES Description Date Amount PFI Permit Fee 12/18/2018 $300.00 PHONE: Contractor: PHONE: FAX: Applicant: DESHAWN WILLIAMS 10800 SW AVERY ST TUALATIN, OR 97062 PHONE: 503-718-6301 Total $300.00 Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact information of responsible parties before beginning work. Permittee/Applicant ((� f� Qi 7 Signature: J�� '1�f uCATLop Issued By: Special Conditions(See Attached) Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY Conditions for PF12018-00345 Type: Condition Name: Status: Severity: PFI Utilities 01 -WORK SITE REQUIREMENTS Applied Notice Applicant must comply with all applicable provisions of federal and state law, the Tigard Municipal Code, and the terms of any agreement with the City of Tigard regarding work to be done pursuant to this permit. PFI Utilities 02 -WORK SITE AREA Applied Notice The work area and approach roads shall be maintained in a clean condition,free from obstructions and hazards. The spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up and suspension of work to accomplish clean-up. PFI Utilities 03 -WORK SITE EROSION CONTROL Applied Notice Prior to starting work, effective and approved erosion control devices must be installed and maintained meeting the Clean Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to accomplish effective erosion control. PFI Utilities 04-WORK SITE REPAIRS Applied Notice Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes, etc. shall be reinstalled or replaced, with like kind of material. Obtain City approval of restoration work. PFI Utilities 05 -TRAFFIC CONTROL SPECIFICATIONS Applied Notice Applicant shall provide traffic control according to the current edition of the "Manual on Uniform Traffic Control Devices [MUTCD]for Streets and Highways", U.S. Dept. of Transportation, FHWA, current edition,American Traffic Safety Services Association [ATSSA], and Oregon Temporary Traffic Control Handbook [OTTCH]. PFI Utilities 06 -TRAFFIC CONTROL PLAN Applied Notice Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work area. Traffic control devices, flag persons, etc., shall be in place prior to initiation of construction work and shall be effectively maintained. PFI Utilities 07 -TRAFFIC CONTROL ROAD CLOSURE Applied Notice Public roadway shall not be closed to traffic, at any time, without obtaining written approval from the City Engineer. The applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and area wide Emergency Services: 503-629-0111 (Tigard Police Dept.,Tualatin Fire & Rescue) and to 503-962-8140 (Tri-Met) and 503-431-2345 (Tigard School District)and other service providers impacted by such closure. PFI Utilities 08 -TRAFFIC CONTROL PROPERTY ACCESS Applied Notice Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City approval of any access closures. PFI Utilities 09 -TRAFFIC CONTROL WORK HOURS Applied Notice Work is permitted in daylight between the hours of 7:00 a.m. to 7.00 p.m. Mon-Fri unless otherwise authorized by the City. PFI Utilities 10 -TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m. to 9:00 a.m. unless authorized by the City Engineer. PFI Utilities 11 -TRAFFIC CONTROL MODIFICATION Applied Notice The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to assure public safety. PFI Utilities 12 -UTILITY NOTIFICATION Applied Notice Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR 952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987. If you have any question about the rules, contact the Center. NOTE. Damage to utilities shall be corrected at the permit holder's expense. PFI Utilities 13 - UTILITY LOCATION CONFLICT Applied Notice Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work (pothole before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work with affected utility agencies. PFI Utilities 14 -TEMPORARY PATCH Applied Notice A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is liable for hazards or damage resulting from the prosecution of the work. PFI—Utilities 15 -REPAIR OF EXISTING FACILITIES Applied Notice Work under this permit shall include repair of existing facilities (roads, ditches, etc.) as may be necessary, as determined by the Inspector, to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit. Corrective work shall be done at the applicant's expense. PFI_Utilities 16 - PRECONSTRUCTION MEETING Applied Notice Before initiating any construction activity, the applicant shall coordinate with the City's inspector, <Insert Name> at<Insert Phone#>, to establish a preconstruction meeting. PFI_Utilities 17 - NOTICE TO COMMENCE WORK Applied Notice The applicant shall notify the City's Inspector twenty-four(24) hours prior to commencing work, prior to any staged inspection, and after completing work covered by the permit. Contact Ken fisher at 503 816 6146 or Kenny@tigard-or.gov prior to and after completion of work. PFI—Utilities 18 - PERMIT/PLAN ON SITE Applied Notice A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work performance. PFI_Utilities 19 -MONUMENT PROTECTION Applied Notice Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's expense. PFI—Utilities 20 - EMERGENCY CONTACTS Applied Notice Provide to the City inspector, in writing, the names and 24 hour emergency telephone number of two (2) persons who have authority to resolve problems, take corrective action and, in general,will be responsible in case of any emergency. The applicant shall notify the City Inspector, in writing, of any/all assignment changes. PFI—Utilities 21 -OTHER Applied Notice -vert RE 'FIVE City of Tigard DEC 14 2018 PUBLIC 1'ORKS — ENGINEERING CITY OF TICA��D s" Public FacilityImprovement TPT'V iffiW a TYPE OF WORK DESCRIPTION OF WORK(in the right-of-way) TYPE 1–Franchise Utility Work Check one: V Utilities ❑ Sidewalk/drivcwav approach ❑ Street improvements performed by N\VN, PGL Detailed description: Replace and repair underground facilities and/or utilitti-agency. ❑ TYPE 2—Sidewalk/Driveway/Sewe>- PGE Job M2495695 Work performed for the purpose of: • Sidewalk installation or repair. Property address/location(s): 8978 SW Refiling St 02 019 • Driveway approach installation and/or repair Tigard, OR 97224 • Sanitary sewer lateral installation and/or main line tap Portland General Electric ❑ TYPE 3—Full scale Development Applicant: Work performed with Land use Address: 10800 SW Avery St approval which includes any of City/state: Tualatin, OR Zip: 97062 the following: Phone: 503-464-7777 Email: preregcoord@pgn.com • Subdivisions or Partitions Contact name: Deshawn Williams Phone: 503-718-6301 • Street.widening • Mainline installation for Sanitary Contractor: Potelco sewer, Storm sewer, Tigard water 76668 and/or Tigard Water Service area CCB#: Expiration: Address: 14103 Stewart Rd SUBMIT COMPLETED APPLICATION TO: City/state: Sumner, WA Zip: 98390 City of Tigard Planning/Engineering Phone: 503-863-7067 L;,ma�: jmlenhart@poteico.net 13125 SW Hall Blvd. Contact naive: Joe Le n h a rt phone: 503-991-1517 Tigard,OR 97223 Applications for"minor work in right-of--way" only may be emailed to: EnginCcr: NSA MINIDCrmits(a—,�tigard-or.gov Address: FOR STAFF ITSE ONLY City/state: Zip: l Phone: Email: Case No.: fi/��I�'C'C>64� Contact name: application submittal fee (.007%of Engineer's Estimate) $ 500 . 4'd:� Estimated value of work is required(if over$5,000):$ additional fees: $ (within the public right-of-way) ,-application accepted: By: /'C Date: Is work related to a LAND-LJSE DECISION? ❑ Yes VNo Application reviewed: If so, please specify (MLP,SDR,SUIS,etc.) case #: _ By: 1'�• 1FIS 14*A-Date: Is work related to a BUILDING PERMIT"? ❑ Yes V No applicant notified: i r If so,please specify(BUILDING PERMIT)case#: By: Date: I:\ENG\PermitApplications\pfi_application Rev.10/16/2017 w%.`Puc m .. .... � `•'1."i»'RRi.' tl .... ...,... ..'"iY "�R�sAa+oeF:$ 4Z';�''P:'a�"`..sa....3.F,S�"t'x`EnAM�.` ti' aebnHSL::x"L t<<.:.,.b.«�..ifi'v'�`.�..,s''.find'3u'FY':a .d'u'A`:Yt313#tt.' YeY1��..aN'�� �ac,s" City ofTigard 13125 SW'Hall Blvd. • Tigard,Oregon 97223 w-,vw.tigard-or.gov 503-718-2421 • Paye 1 of 4 APPLICANTS NOTE: Person specified as "Applicant" shall be designated"Permittee"and shall provide financial assurance for work,if required by the city pursuant to TMC 15.041.140. * With the exception of a utihtV operating;pursuant to a valid franchise with the City of Tigard,when the owner and the applicant are different people,the applicant must be the purchaser of record ora lessee in possession with written authorization from the owner or an agent of the owner. The owner(s)must sign this application ui the space provided or submit a written authorization with this application. Franchised C Jtihties are not required to obtain the owner's signature on the application BY SIGNING BELOW,THE APPLICANTS) SHALL CERTIFY THAT: • The above request does not violate any recorded deed restrictions that may be attached to or imposed upon the subject ro ert • If the application is granted,the applicant will exercise the.rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. • All of the above statements and the statements in any plot plan,attachments,and exhibits transmitted herewith,are true;and the applicants so acknowledge that any permit issued,based on this application,may be revoked if it is found that any such statements are false. • The applicant has read the entire contents of the application,including the policies and criteria,and understands the requirements for approving or denying the application. 15�t2v4w, c� Lzlt� Steve Hursh 12/14/2018 ,applicant/Authorized Agent's signature Print name Date SIGNATURES of each owner of the subject property, if required. Owner's signature Print name Date Owner's signature Print name Date Owner's signature Print name Date PUBLIC FACILITY IMPROVEMENT PERMIT City ofTigard 13125 SW Hall Blvd. • Tigard,Oregon 97223 • ww,,vtigard-or.gov 503-718-2421 Page 2 of 4 DEVELOPMENT ENGINEERING FEES FOR STAFF USE ONLY Public Facility Improvement(PFI)Permit: DETAILED REQUIREMENTS APPLICATION FEE Part 1: Required submittal fee$300.00 (nunitmum) FRANCHISE UTILITY AND SIDEWALK/ DRIVEWAY AND UTILITY PERMIT FEE CONNECTIONS,ETC. Part 2: All non-water system improvements (work in the right of way) Engineer's estimate X S%(less$300.00 minimum Sketch submittal fee) (including information below) Engineer's estimate X 2%Plan Review ❑ Dimensions WATER SYSTEM FEE ❑ Street Name Part 3: All public water system improvements ❑ Site Address Engineer's estimate X 12% FULL SCALE DEVELOPMENT PFI Permit Fee Exemptions: (Subdivisions/Partitions and Street Improvements) There will be no permit fee charged,or assurance required for the following types of work: Design Plans • Sidewalk repair (less than 20 lineal feet) (6 sets,24x36 or 22x34) • Relocate or replace mailbox ❑ Cover—Site,Vicinity,Abbreviation,Legend • Ditch cleaning that does not involve regrading. ❑ General Notes(City,Water,Sewer,etc.) • Weep hole repair ❑ Street(Plan,Profile) • Curb repair or replacement(less than 20 lineal feet) ❑ Water,Storm and Sanitary(Plan Profile) • Lawn sprinkler system installation or repair ❑ Water Quality Facilities • Street tree pruning or planting ❑ Grading • Planter strip landscape maintenance ❑ Landscaping/Tree Plan • Test wells ❑ Composite Utility Plan(Electrical,Phone,Gas, Storm,Sanitary=,Water,Signage,Street Lights,etc) ❑ Details Note: A cash/bond assurance maybe ❑ Traffic Sight Distance required per TMC 15.04.140. ❑ Signing and Striping (customer deposit) ❑ Street Light Plan and Photometric ❑ Engineers seal/signature ❑ Sheet label(project land use name,revision and plan log block,dates and sheet numbers.) Additional Submittals (per Land Use conditions) ❑ Traffic Report ❑ Storm water Drainage Calculations ❑ Geotechnical Report ❑ Preliminary Access Report(Sight Distance) ❑ Proposed Plat ❑ Pathway Design(if applicable) ❑ `eater Department Approval ❑ Engineer's Construction Estimate PUBLIC FACILITY IMPROVEMENT PERMIT City ofTigard 13125 SW Hall$lvd. • Tigard,Oregon 97223 • urunvtigard-or.gov • 503-718-2421 • Page 3 of4 w jwra SAMPLE SKETCH: Edge of Pavement -A*- Ditch -op Streetlight ._._._._._._._._r_._ Rain Dr--Lm �-' ►- 1_4 House IN Existing ` }1 D rivewa y 1 �1 I 41 1�r OR M' t (j . I Ex'51'ng Shop I C I1 Powerpole / 1171!� _ ' '------- - ---------- o p rty Lne I I " Fire Hydrant(FH) I i I I I Scale: .I"=30' I I 1 I I I � I I I I I ( i MINIMUM SKETCH REQUIREMENTS (Put"N/A" if Not Applicable): Noi:t11 arrow Property lines & dimension Slope of property- Street &street name(s) Existing building, structures Utility &street light poles Proposed work Existing curb or edge Trees Existing S/\t' or of pavement Existing utility locations D/W apron (sewer,water,storm) PUBLIC FACILITY IMPROVEMENT PERMIT City ofTigard 13123 SW I-fall Blvd. • Tigard,Oregon 97223 • wwmtigard-or.gov 503-718-2421 Page 4 of .,a B2A «N Nr na .r LEGEND «r Kl'ry,EEROq(t) Op« D,u =.mon rx._xwrum• CONDUCTORS are rna, r.r 0]w x r Bxa:m nr .....--. rwwaiPww xi» )Im [rr ¢PD.sosa: acre w» .rrr +ero o w «aXu«rurrr mFe,»NNn yvtnu MEw 5N1 e4�R1lBOWrm-JKiD GOLF IML 1°°f w rw Hv.4rD-ren. nw nm a°°° __._.... wam.rw.. Fx6Ufa0N-VAULT CONC.«YNI IYOD UVdM P`ELBOW KR•—D-BLE,IML xNi rrrc,«wr +JDDON-LONG.XONSti VLT Lb 504S0)C SDM D R RI ELBDW,OT-JKTD GBLE-0)AL ] [[. ....r .o• UTEMITAP g11i•1 Pobr PNASE F«iP� n•RI EIBOW INi-JKTD GNE-D]AL _ 111E—IUT•JKTDCABLE IJAL IBOWgFJKTD GnFIMI EOEAPMENT WBT GP Nr '. BACKOF NlY R W� 'JKTD GeIE-KAL NOTE STRERE SNOT ALR066 ET «rrmr rvrr m,.nx 9TREmNEFOREI NOTEIN—U. raxa «rn Mr xJ» NLN INTO dNVEWAY � wx.x.r mun VT•1DT MEW SNI: LI'-' V RR-JRTD GBLF IML KEK-VMJLTCONG65 42ODUVON CONC.NO«SLNVLTLIDSClAMSO 0 VOU]K0E-VAULT CONI.]2YN1W'OD.WnKrt-JRrD a,ASB 203tS uTERurAP UMT—1 MUSE Pu /JCF•MTO CABLE 1sRv-IJu NK Hallo C11•11A w..u..n•,xr ,• III ELBOW RR•JKTD CAB E-PDLL eo«rl � rTOan NOTE:NSTALL MCR OF W RB IS ,aw NOTE'.M•TALL BACK OF CURE «nr Um Ilr» POLES «TID Gra +•f «« +R 1 r «"• � `PoIE NEIONi rNx Mw 11111660147 µ� roN JVaN«.otro 1wr « ww rr AELATEO AB.S eWSCNECMADA r1° zr OR0DTNI DIA,JIAAI NDRTIIN 1MIa A Y «N MNriDK OIEIIAMNOR]NM . w =1aWGDYAP%f LM A m TKS � ro-r vu, �'" —11—MD— rol[n P`,:a «fw PAFurotcA AE CS «'J 1Yl/1D,0D2: YOV!wo Bus,Ns A BQ .• r am SR2.OM • •o.w IN rorr ' %fAONf OP TRANBfDRYER R i►� r �r�• •' w lOtf-LwMOt A,vID Nlla K•� :T r rl[If r ram ,.r WLIS YTMi: 1fED A n,2., xna vK ■*4 The 11DA+l/p MOTEI "+a � ifN' r rlfu ^mi..ID-,feo. '«x ra.N wl.l/6)K2:RNOV! LBOW KR-JKTD CABLE-RAL fADNI OP 12TAJWI�! A)S TIK rr 1Da f � aar eon ,1 P EELBOW Nr-MTD CMIE RAI ro>r j wr 1 len wr N Po-%«: ..r [ ANnzSD w•1_ « »r �f ,IDG , �: XELBDW Rrt-JRrD cANF mL �ie[r.+ .o.a D • °i• P Rl Eleow Krt-JRTD GB LE-t2hL x xNF ¢,F• tF _- .i w xwe H°01 Y «rr r NOTES ,Nm ?• VRrM�•• 16< ror ,.MUST MANTAN 5 FT.HORUONTAL SEPARATION FROM IF »r men` � Yam�_R•�»___ Dau- bf • c WATERaWNSANDI FT VERTICN SEPARATION BELOW. tW °� T •---_• S ff4arww M 2.MANWRr FT.SEPARATION FROM CITY OF TIGMD JEALE � ,r r• nT •••, ' vc1°y.,' �n v"r 1.USE 45.1 N'BENDS FOR OPEN BOTTOM-ULTS. S02]i1 [[II wle A / [Iw a1r I»a Irn RN FIELD SNITCHUTBEP LLBOVEGNADETOPE—END). FOR ro •� ffm M,F arw rr1 SNITCHING.(PULL TENbb«b ASSUME DD•eErq. Irs xr • ._._.._yw_... ww w Jro-]sa5. i M• .-. _____._... _ I 1 R09DNW »[f. � 1 gSCOVEEO WRING ELONb'TRULTION. AWZMItB C.l1R ,x^21 ELBow KR-Mm G01E-IML P ,[ffl e�EIBOW KR•JRro GBIE 1Al « w•r1 BSB 210}6 w f Pef21 ELBOW RR-JRTD GBLE-IML trf •. ]fNPnrfr S.GROUND ABANDONED GBLE PER LL22WS], NOTE TREE TG BE REMOVFDN kw• :� » RR)ELBOW RR-JRTD UBLE-DML nr r• k _�T ' b¢^ AJaww•roA,rN 6.LHELK COORgNATION OF STREET LIGHT FUSING AV3ET FRONT OF M)BN j ,r2 rr rw «w - ._.. ].INSTALL PRINMY GABLE BALK CF LURBNNEIGIIBORH000. r° r, _- rra 1-LINE DIAGRAM MEWSNI .r >r• w .a K,: Wim' n Fra[: •Iw2KN-VAULT CDNc.srrwTlr DUuu.so. ELBaWRR•JRm.mu,NAL ar-sw VLT Lb x.se•Te-solrs[s ,rr UTE0.AL TAP UNR-R POS PHASE ¢ [WELBOW RR-JRTD GBLEfOAL 101 ELODW NR-ARD UOLE->h Al rarf Iaa1a 1'N ri DUrrcAP »ra j F °a.�+ 1°10 875-1 _ cz r•neam* � aWOAAlrcr «►� An rDK Iwn AW2 l +N fm1 — v � C21 FIAF:zt IN ,,• :•rr Q 1w naF 650N332 11 R [ 1 ra+ _RIB ELBOW RR-JKTD GBLF IML +�,r •� 'Ir>¢° « 4� �;.• �Ialr «tw 'JM'IfLJ11J/OIp 67 F PJ EL•DW KR•JKIp CABLE pAL 1 • rM - `O•✓<+ r ,r ���•• wr .r r E N 1C �- ,n -A _.•,u WORK AREA , nal ,ra wr Y: xrr a .� • ASO 20}OS AfO t1K1ro l ,B • •WR arw wf[I s Y 1111 ffN 1°11 rr ,ar C21-HD aiN 1ti C N aw R wt". N. B, fN ._...___'. w -„ „m Jan ----- ' ' 2,.,,o-c:1a JPo-nN. rwAAc r.NNr „ »+ rr - tWa�� _ wCrws Fr ELBOW Rrt-JRTD wLEI 1. N—TssoflA Y1}E81>M P.waw. Ixr ,Iwr 6WA rW RJ ELBOW RR-JRTD CAOLF t]AL , ,w n 1261 n nr ,ar DI roan A]B K0i0 sn ,n¢J �• r1' , 0 141210 MiM F - BFrfgR.v f.ft r nr f,w n1. r[r1 19HJ - F••:ELBOWILR-JI[TO GBLE-DMl row »m f1f1 n« nr n m, _ �1 RIr-MTD GBLF 02AL C IS a5)ri fI+I'+"x'SIV CORTGJm LN F(21ELBOW ' � W1 C33 K2112 rrr r ANY pE17A/XJN FM7A1 TFEf OE9u7LI AA/S! tr m .« I a JX.MNSPV@9YTNF H`fi CB2EL7A11N1((if abWdwNeN,, rom l0. ao-rr 11°A w • ` • T rr Re aweRAwNJ.N b W« • ® THINK few F3 xr. rR ew: ,w¢v°,a•INEwsNIna+:n SAFETY RI N2cCONDUIuo TAv wwfrom uv rAv ,N nr alr 1-N wecoNOLllr wrt 11N rvc corn urR wlr eRTs »w NBK lar Ilaf rrz 4O nIrwYYs M'suDfaee-VAULT caxc.sDtBnllr oD uvAN ,auD floor uG TAP FIR3T a,m NfN Ill tb ff6T UO TM O11]Cro FIWL UD TM taw SUtNN-CONL.Mp4Sl1P VLT Lb 6IB6611I 60«S01 2N PVC CgJWR UNR Wl12 �Df11DAft •i15 M fONUO TAP R 2-M rvL LONDURUNR LATERAL TAP UNR•1 POSt RIASE (21>Nwccaro —ft RFA,OVE r0'BRACKET A2SAW 14)El,BOWW-JIRD CABLE SAL roTEw.NsrALL eAca of wRe N IS LAN: «r w � ....__...._..._.. _.... Dx.mJFPrrmrr: ,are raw rfn 4 Gar ASD 2nDa 1N MEw snl. a1VOP.16ENs)FNLN rA +on BZD1e 11n=6oA IB]aNI l00000]aD1 DSKS �,vr- rr mif'Iy wLm LN wJACRErEDCABLEREPLICE1 n v—:—LTCONL.sr 7TDOUvsn w. ae ` DURHAM NaRTH r-s n C5BN2i1 t nr,� 0-CAIJC.ON NOM6lp VLT LID S[1N"nZSTMST]-W ,+1 P6169 Isw \ W1111415r1T-ILE0. 2[FIO IATERKTAIUNITN PoSO RMSfC?S KI,S IN + PC. K}[tW RERNOtT,MMRO Pi2N siw.,o ONON (51 fIBOW Im-JKTD GBLE-IML ww Ir wN •ple •� — wN nr nr I C3055115 A NRµL,E BMRB,K:I SPIN x[Lr �• raw xa (7)DUST GP Y aar v rN w« ax Svwar5 NOTE'.SPLICE ID MERLEPT FIUSTNO CABLE AND—IT LWINDIOJ Mel(— IOfl NEMNB" FROM n-1510 TO VT•]IDO ' , N wv DESXIIM SMLLMr a0Y rEr1 PRIMARY CABLE St CONDUIT TABLE LEGEND PD-9039 EONo Nr nsAl\Nr tAsla Aol ar t rosluTloN 1OGTd1 f9a an LONG.1et+IN wu wu Y>.sle 1!11\111 LosslN ----------- 10#2 EPR In 2"HDPE CONDUIT 1 IMI OONM AC1DAl IIN OWN ACIYAI "¢��'" Host is 00 IN) DL.I W) Iw+T>s. IM IRI sore 10 1/0 EPR in 2"HDPE CONDUIT 1 VT 521 ommI yr-M 4 I is 11 v In& Q PD-7662 ' . rtls x 1 sl a Q QA. m 1 PD-7865 3W 1fa : I 4f f w RAL sm crass 1 _ fR I 1 xm 31 Q QAL m 1 1. MUST MNNTNN 5 FT.T.WRRTN.SEPARATION FROM >W P 3 1 STt lel I) RAL 0 WATER YAKS AND 1 FT.VERTICAL SEPARATION BELOW, tt-W x 1 45{ ]9 f RAL 9 2.M/YNTNN 1 FT.SF➢ARATgl1 FROM fJtt Of nGARD yll I tt-W VFs x 1 IA IS n RAL 173 CATOI BASNS tt->f J 1 a 0 4 RIX R 3 FICEED CUT BEND ABOVE R OPEN TO PROW VAUULACN 11 IP-6 'Ir VF-m fN ] 1 NO f ]5 0. S# FOR SNITCHING.(PULL TENSIONS ASSUME YO'BEND). 11 f I 11 J dw x I m f Q ORALIN 4.REPLACE GROUND RODS IF EXCES9K CORROSION IS-7 ural vFw ] t s f f Qu els OISCOVCRED DURING CONSTRUCTION. 1 I I / E1 Vr-17\ ME x I m Sx f Qµ f3 5.DROUND A ROINA ED OF S PER LC24T FUS. PD-7663 t3= 1 IP-2 } ff tt-m 2 1 m f f RA< If S.CHECK COdONA ON d<SiRECT UGH7 FUSING. 1 PD-9038 N-m 0.1milml x 1 m IS f QAI m 1 VT-164W-vs P&IRIMI z 1 30 a.s 4 Qf II I Iim Yrs ] 1 W 57 w 'am m 1, IP-3 L1�17 + Yr+► TQ x I m a m QAL to Haf ]ml x I w Q n QAL xm �i ---- --- ' PD 7863 Vri T4f 1 1 W If tl QAl W `VT-293 IP-1 1 i VT-173, PD-7860 Tr[I zJ¢ sm I i �_*1-2"M2495699 u tl ' -1`__-, DURHAM NORTH N N' IP-7 TRENCH-FOOT TABLE ' I n ' I N ' 1 N EDtnln PD-9040 fN 'D[11pA 1m an IfKIN uw1N PD-7664 it IRIpY 10 IW Der\R A(m ' /( VT-497 Ifs tt-s I I tta tf4 x t ' IP-5 ; TRANSFORMER LOADING "" ' ZIA In w z I 1 INN4 sa Dos s IIM in xsf ' PD-7862 IP 81�PD-7861 A n An3ms(vaRe¢e¢sl 11 m ND w Isa 192 l I VT-209 � '^ w 1 to A IS An>IR(mcu1¢....)t X— rQ w yr-W VFW 1 --- A n AnTaf 11c¢Mw¢n asraw No w w II A f ASOxfle 4CYr¢n[n xLi>Xw NO, w yr-m PL-1520 A f fm4l ss 31fNWr iq M PL-1519 A f .—Mss xam w w w 1 SPLICE/INTERCEPT A n AnvTmnjw "m w R tstf = 1 N u EXISTING CABLE 8 A Se A'0�\°'°""` 1eT'°A No Yr-xEs ff ii CONDUIT FROM A f Afsu>�¢¢N¢, NEZ W A f ASII m 7cw"ANI. nwnv rQ YT-m n-xn E II PL-1526 TO VT-7400 A f Afxlfl]4LNawn "'OR No n-tn w L II A 50 AfrilO]t:up¢wN1 &SSXW NO wP&RIS w tt-m I Vt.= pdRlW4 ] zw Y tt-1n mI t II ff n 1 II r> vra> 1-2"M2495688 ' ttaf N DURHAM NORTH K,-Ji N 1N I w m x 1 ss � n sir 1 1-2"M2495688 DURHAM NORTH K 5 Vi-181 N 5 VT-293 �b - _IM3 �A - v¢t 5G' \wyfp-y -P[Z VAtAT \ SOMP4EULT �t C>ISTNG PA] EXISTING PAD �+ [vl5t.4G r u", - IO I r NWY r_ To PD-TaaeE-� yro yr-2Da °� ly to� Jvr sxlT�',"'r ro yr-4n(J�jTo Yr-m `-fro yr-w> A.E «i nv ®F.R EXISTING PAD -VUJW ��5¢� t�. VT-497 [�'N\ - "Fong.ver .IW vrwAl�w rr I N ZS} MVEW1f. SM-�VAULT 1 L%ISP.NG PAD '"Y"Y•Y•�''•"'"�' U-4 f ' f$l�IiyLJJ.lf1lR�^T _ 8fi BEFORE YW DIG ']X � sN wYEZIsnNC PAD YwlrsIr :RusmMss ams P ION D 01VAN c.s bN1¢N Y¢f elD. rD PD->ee4![--I LjT°PD-7aez s� To vT-le. .' aFTo w-z1::2 i AQ �o' �YO vGE CONSTRUciroN UALT BY E Nan cover c�w"wA ro R-lel �u-T".cd"cIw A �O W-��W"�� �PAEFG RENEW ASBUH.T BY DESIGNER: AS-AUl1.T VERIFICATION 6 NESC VIOLATIONS CORRFCTFI) rn��,,. onr Avr"roN�.r".«NX»FI r [45nNG PAD EbSTWG PAD eO4-p¢VAULT \ - Pw - Or XI\ - %_21 VT 209 _lLm I.N w"o�u"•'i�" m w p tin T, EXISTING vf.¢PAD I EwsnNG PAD eyor�IN¢x�,sWr vAu> \ Fawnen: Dm: o • r �' .FXV a Yfww bl� NI un oo "��' MY'M'1! `0i� OF tOlszOle r NTS "IL 11]TOWt Iwo t000m>B]4 ^'Y'"�M29 95 k Q jr,Ij^` y •^10 "'� ��qR�W 'X.—KETED GBLE REPLACEMENT-DURHAM NORTH M-5.933 FT •w •"\ P 11, 4�4.RV"N,`S^N /A.C�+ OURIUM.4ATTLEA2e%40 1pGE [m>\SW ROILING ST.T%iARD.OR,BT1TI �IQp�p1 Ni wa ffMt�T COIWIIA1MI011 ~�4 �Y IYWI NQi1N�lI�d1 WYY �C� CESM[+Ilbe uN�yy��> 1( +,- NSTN1(1\)SPANS A-0(t)SPAN tN K;(8)VAUL� INna r 0 PO f]eeJ NqA^*NsgwA ORY,PJ `-ATO VT 521 "VT-.9-/! E- bWAS�INGTONRINIC31 T1D,Cx111A — Swe0ELg14II RO.DESMAWN WLLIMIS 303-]186101 FEIq BOOI.ER WXSONVILE.OR9N10 OP[avnANO CErER.II HFCIRC CO-Al[bOlIr9 REeFRVEO --------------------------------------------------------------------------------------------- U) 1 I (J1 Ut -N A W W N N 0 (r O Ci O Ut O Ci O ! CD CD Single Flagger Operation (Optional) for Low Volumes &PAR (Optional) P <AHEAD NELANE w, ROAD 1 iM U W � (ADT < 400) .� 0 (n o >-0 � O O o W `2 1 � CI) z F-AGGER BE ONE LANE A a PREPARED r B c ROAD (° :+ :+ :+ :+ TO STOP AHEAD O C" O � _W i ♦� 1 mile ♦� M O O O _ max. • ° ROAD ° 0 ® °° ♦ !to CD r WORK O (D . . +. cn w = I .C a e A f AHEAD (n Dn 0 0 0 ? _ N L Protection Vehicle ' CD A`' wITMA(both Optional) CD BE See Chapter 4 ; 0 PREPARED [D <9> TO STOP N N -0 C (51 --� CD 01 N O (J1 Q Sv � 1 0 0 0 O C1 0 Q rf CD `-° A B B C 1 ' (Optional) ; ------------------------------------ l 1 mile_ U3. *� f max. 0 0 0 � 0 0� o 0 0 000 0 U O C B BA Buffer Protection Vehicle w/TMA(both Optional) ROAD See Chapter 4 WORK AHEAD BE O ROAD E PREPARED Two Flagger Operation a} AHEAD TO STOP W � (Optional) C E� v 0 n 0 www.invarion.com Stationary Lane Closure with Flagging Diagram 320 Diagram 320 covers total closure of one lane of a two-lane, two-way roadway. See the detail inset for the layout if using a single flagger to control both directions of traffic on low volume roads (less than 400 ADT) with good sight distance as discussed below. 1 . Use truck-mounted flashing warning lights on work and protection vehicles. See Section 4.3 — Lights and Lighted Signs for exceptions. 2. For added visibility, a truck-mounted arrow board or PCMS in caution mode may be used. 3. Flaggers at each approach are required if any of the following conditions exist: a. Night Operations. b. Work space is over 200 feet in length. c. Sight distance is less than 750 feet from each approach through the lane closure. d. Traffic volumes are greater than 400 ADT. 4. The length between the Flagger Ahead signs shall not exceed one mile. Use Diagram 340 — Lane Closure with Pilot Car if exceeding one mile. 5. Cones should be used to outline the work space when curves or other roadway alignments prevent clear direction for the motorists to pass the work space safely. 6. Cones along the work space are recommended when posted speeds are 45 mph or greater, when working under heavy traffic or when travel lanes are narrower than 11 feet. 7. Extended queue signing (see Diagram 5-4) should be used when traffic queues extend beyond the initial advance warning sign. 8. When flagging near an intersection, the "Flagger Ahead" (CW23-2) sign should be visible to traffic entering from any side road. Additional advance warning and Flagger Ahead symbol signs may be placed on the side road(s). 9. Sign set-up and flagger placement shown may be used for intermittent full road closures of 20 minutes or less. 10. The "ONE LANE ROAD AHEAD" (W20-4) sign is optional and should be considered on high volume or high speed roads, or when extended queues are expected. www.invarion.com Lane Closure at Intersection with Flagging Diagram 620 ROAD WORK AHEAD •l t (Optional) ONE LANEROAD AHEAD W" ,B:z • A (Optional) C ONE LANE ROAD O BE AHEAD 100 ft.Max. ROAD PREPARED WORK TO STOP AHEAD O A B B C Buffer c O G � % J o 100 ft.Max. C B B A ROAD BE WORK PREPARED AHEAD TO STOP 100 ft.Max. ONE LANE � ROAD AHEAD if i, (Optional) A B ♦ BE PREPARED TO STOP B (Optional) ♦ ONE LANE ROAD AHEAD C ♦ ROAD WORK AHEAD www.invarion.com 11-ane Closure at Intersection with Flagging Diagram 620 Diagram 620 covers work within an intersection when normal traffic control must be interrupted. Work vehicles may or may not be in the work space. 1 . During flagging, traffic signals shall be turned off. Contact the road jurisdiction for approval and assistance (see Chapter 3). 2. For multi-lane facilities, traffic approaching the intersection shall be reduced to a single lane on each approach. See Chapter 3 for information on flagging through intersections. 3. There should be one flagger for each approach. One flagger may control two adjacent approaches if sight distance, low volumes on side roads, and flagger position allows for safe operation and clear direction to motorists. For low traffic volume intersections (fewer than 400 entering vehicles per day), one flagger may be used. 4. The "ONE LANE ROAD AHEAD" (W20-4) sign is optional and should be considered on high volume or high speed roads, or when extended queues may be expected. Sign Spacing and Buffer Lengths (feet) Posted Spacing Between Signs Buffer Speed A B C Space ERRATA: 20 50 25 100 100 100 75 Supplement Table 30 100 35 350 350 350 125 Updated: February 12, 40 150 2016 45 180 By:ODOT Traffic-Raodway 50 500 500 500 210 Section 55 250 Signs Spacing and Buffer Lengths (feet) Supplement Posted Spacing Between Signs 19Buffer" Speed A B C Space 60 2 8, 65 700 700 700 325 70 365