Loading...
PFI2018-00339 III CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT COMMUNITY DEVELOPMENT Permit#: PF12018-00339 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 12/13/2018 1 Parcel: SEG1028 Jurisdiction: Tigard Site address: Subdivision: Lot: Project: PGE Job M2641786 Project Description: SEG 1028, associated with 14595 SW Horizon Blvd. Install conduit from transformer 50 55100 to pole PL-162. PGE Job M2641786. Owner: FEES Description Date Amount PFI Permit Fee 12/13/2018 $300.00 PHONE.- Contractor: HONE:Contractor: PHONE: FAX: Applicant: JASON MORIN 10800 SW AVERY ST TUALATIN, OR 97062 PHONE: 503-672-5474 Total $300.00 Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact information of responsible parties before beginning work. Permittee/Applicant Signature: See application Issued By: C Special Conditions(See Attached) Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY Conditions for PF12018-00339 Type: Condition Name: Status: Severity: PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice Applicant must comply with all applicable provisions of federal and state law,the Tigard Municipal Code, and the terms of any agreement with the City of Tigard regarding work to be done pursuant to this permit. PFI_Utilities 02-WORK SITE AREA Applied Notice The work area and approach roads shall be maintained in a clean condition, free from obstructions and hazards. The spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up and suspension of work to accomplish clean-up. PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice Prior to starting work, effective and approved erosion control devices must be installed and maintained meeting the Clean Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to accomplish effective erosion control. PFI_Utilities 04-WORK SITE REPAIRS Applied Notice Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes, etc. shall be reinstalled or replaced, with like kind of material. Obtain City approval of restoration work. PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices [MUTCD]for Streets and Highways", U.S. Dept.of Transportation, FHWA, current edition,American Traffic Safety Services Association[ATSSA], and Oregon Temporary Traffic Control Handbook[OTTCH]. PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work area.Traffic control devices, flag persons, etc., shall be in place prior to initiation of construction work and shall be effectively maintained. PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice Public roadway shall not be closed to traffic, at any time, without obtaining written approval from the City Engineer. The applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and area wide Emergency Services: 503-629-0111 (Tigard Police Dept.,Tualatin Fire& Rescue)and to 503-962-8140(Tri-Met) and 503-431-2345(Tigard School District)and other service providers impacted by such closure. PFI_Utilities 08-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City approval of any access closures. PFI_Utilities 09-TRAFFIC CONTROL WORK HOURS Applied Notice Work is permitted in daylight between the hours of 7:00 a.m.to 7:00 p.m. Mon-Fri unless otherwise authorized by the City. PFI_Utilities 10-TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice Hours of construction work on collector and arterial roads will be limited'to 9:00 a.m.to 3:00 p.m. unless authorized by the City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m.to 9:00 a.m. unless authorized by the City Engineer. PFI_Utilities 11 -TRAFFIC CONTROL MODIFICATION Applied Notice The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to assure public safety. PFI_Utilities 12-UTILITY NOTIFICATION Applied Notice Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR 952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987. If you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit holder's expense. PFI_Utilities 13-UTILITY LOCATION CONFLICT Applied Notice Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work with affected utility agencies. PFI_Utilities 14-TEMPORARY PATCH Applied Notice A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is liable for hazards or damage resulting from the prosecution of the work. PFI—Utilities 15-REPAIR OF EXISTING FACILITIES Applied Notice Work under this permit shall include repair of existing facilities(roads, ditches, etc.)as may be necessary, as determined by the Inspector,to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit. Corrective work shall be done at the applicant's expense. PFI_Utilities 16-PRECONSTRUCTION MEETING Applied Notice Before initiating any construction activity, the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert Phone#>,to establish a preconstruction meeting. PFI_Utilities 17-NOTICE TO COMMENCE WORK Applied Notice The applicant shall notify the City's Inspector twenty-four(24)hours prior to commencing work, prior to any staged inspection, and after completing work covered by the permit. Contact Ken fisher at 503 816 6146 or Kenny@tigard-or.gov PFI Utilities 18-PERMIT/PLAN ON SITE Applied Notice A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work performance. PFI Utilities 19-MONUMENT PROTECTION Applied Notice Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's expense. PFI_Utilities 20-EMERGENCY CONTACTS Applied Notice Provide to the City inspector, in writing, the names and 24 hour emergency telephone number of two(2)persons who have authority to resolve problems,take corrective action and, in general, will be responsible in case of any emergency. The applicant shall notify the City Inspector, in writing, of any/all assignment changes. PFI—Utilities 21 -OTHER Applied Notice RECEWED City of Tigard DEC 112018 �1T,,of rrG a PUBLIC WORKS —ENGINEERING pLANN1NG/ENGINEE„t � NG tYImprovementmiPublic Faces (PFI) Pert TYPE OF WORK DESCRIPTION OF WORK(in the right-of--way) TYPE 1—Franchise Utility Work Check one:V Utilities ❑ Sidewalk/driveway approach ❑Street improvements performed by NWN, PGE Detailed description: Install conduit from transformer 50 55100 to and/or utility agency. pole PL-162 ❑ TYPE 2—Sidewalk/Driveway/Sewer PGE Job M2641786 ��� 1028 Work performed for the purpose of. •• • Sidewalk installation or repair. 14595 SW Horizon Blvd • Driveway approach installation Property address/location(s): and/or repair Tigard, OR 97223 • Sanitary sewer lateral installation and/or main line tap Applicant: Portland General Electric ElTYPE 3—Full scale Development Address: 10800 SW Avery St Work performed with Land use approval which includes any of City/state: Tualatin, OR Zip: 97062 the following: Phone: Email: preregcoord@pgn.com • Subdivisions or Partitions Contact name: Jason Morin Phone: 503-672-5474 • Street widening • Mainline installation for Sanitary Contractor: TBD— Permit needed for bid walk sewer, Storm sewer,Tigard water and/or Tigard Water Service Area CCB#: Expiration: Address: SUBMIT COMPLETED APPLICATION TO: City/state: Zip: City of Tigard Planning/Engineering Phone: Email: 13125 SW Hall Blvd. Contact name: Phone: Tigard,OR 97223 Applications for"minor work in right-of-way” Engineer: NSA only may be emailed to: romPermitsa.tigard-or.gov Address: City/state: Zip: a Phone: Email: Case No. U ZU 1 W'31 Contact name: Application submittal fee(.007%of Engineers Estimate) $ �d�• o Estimated value of work is required(if over$5,000):$ Additional fees: $ (within the public right-of-way) Application accepted: �� Is work related to a LAND-USE DECISION? El Yes ',No By: Date: If so,please specify (MLP,SDR,SUB, etc.) case #: Applicatio reviewed: By: S Date: /Z—1 > Is work related to a BUILDING PERMIT? ❑ Yes ❑ No Applicant notified: If so,please specify(BUILDING PERMIT)case#: By: Date: �- I:\ENG\PertnitApplications\pfi_application Rev.10/16/2017 BS:..;s4'e cvt[:. +«.,..:., .•..::^d.*a.3,3Y+^�c4mi.8+its.?aeR7.& �.:�-2-(r...rrX�.sR,;,w&3Ytif:rs�.ssYrrs..,h }maswa�dn;iMs::.4tiSntstdNs"+.9rsa '*F:,w-,s' - - saw. _. :: City ofTigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 Page 1 of 4 APPLICANTS NOTE: Person specified as"Applicant"shall be designated"Permittee"and shall provide financial assurance for work,if required by the city pursuant to TMC 15.041.140. * With the exception of a utility operating pursuant to a valid franchise with the City of Tigard,when the owner and the applicant are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner(s)must sign this application in the space provided or submit a written authorization with this application. Franchised Utilities are not required to obtain the owner's signature on the application BY SIGNING BELOW,THE APPLICANTS) SHALL CERTIFY THAT: • The above request does not violate any recorded deed restrictions that may be attached to or imposed upon the subject 12rol2em. • If the application is granted,the applicant will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. • All of the above statements and the statements in any plot plan,attachments,and exhibits transmitted herewith,are true;and the applicants so acknowledge that any permit issued,based on this application,may be revoked if it is found that any such statements are false. • The applicant has read the entire contents of the application,including the policies and criteria,and understands the requirements for approving or denying the application. v- Aroun Xaybanha 12-11-2018 Applicant/Authorized Agent's signature Print name Date SIGNATURES of each owner of the subject property, if required. Owner's signature Print name Date Owner's signature Print name Date Owner's signature Print name Date PUBLIC FACILITY IMPROVEMENT PERMIT City ofTigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov 503-718-2421 • Page 2 of4 DEVELOPMENT ENGINEERING FEES FOR STAFF USE' ONLY Public Facility Improvement(PFI)Permit: DETAILED StIBMITTAL APPLICATION FEE REQUIREMENTS Part 1: Required submittal fee$300.00 (minimum) FRANCHISE UTILITY AND SIDEWALK/ DRIVEWAY AND UTILITY PERMIT FEE CONNECTIONS,ETC. Part 2: All non-water system improvements (work in the right of way) Engineer's estimate X 5%(less$300.00 minimum submittal fee) Sketch (including information below) Engineer's estimate X 2%Plan Review ❑ Dimensions WATER SYSTEM FEE ❑ Street Name Part 3: All public water system improvements ❑ Site Address Engineer's estimate X 12% FULL SCALE DEVELOPMENT PFI Permit Fee Exemptions: (Subdivisions/Partitions and Street Improvements) There will be no permit fee charged,or assurance required for the following types of work: Design Plans • Sidewalk repair(less than 20 lineal feet) (6 sets,24x36 or 22x34) • Relocate or replace mailbox ❑ Cover—Site,NTicinity,abbreviation,Legend • Ditch cleaning that does not involve regrading. ❑ General Notes(City,Water,Sewer,etc.) • Weep hole repair ❑ Street(Plan,Profile) • Curb repair or replacement(less than 20 lineal feet) ❑ Water,Storm and Sanitary(Plan Profile) • Lawn sprinkler system installation or repair ❑ Water Quality Facilities • Street tree pruning or planting ❑ Grading • Planter strip landscape maintenance ❑ Landscaping/Tree Plan • Test wells ❑ Composite Utility Plan(Electrical,Phone,Gas, Storm,Sanitary,Water,Signage,Street Lights,etc) ❑ Details Note: A cash/bond assurance maybe ❑ Traffic Sight Distance required per TMC 15.04.140. ❑ Signing and Striping (customer deposit) ❑ Street Light Plan and Photometric ❑ Engineers seal/signature ❑ Sheet label(pro)ect land use name,revision and plan log block,dates and sheet numbers.) Additional Submittals (per Land Use conditions) ❑ Traffic Report ❑ Storm water Drainage Calculations ❑ Geotechnical Report ❑ Preliminary Access Report(Sight Distance) ❑ Proposed Plat ❑ Pathway Design(if applicable) ❑ Water Department Approval ❑ Engineer's Construction Estimate PUBLIC FACILITY IMPROVEMENT PERMIT City ofTigard 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 Page 3 of4 SAMPLE SKETCH: Edge of Pavement I 1Ditch Streetlight I —•—•—•—• •—.—.—ri• — RAJn Drain � I ' T 'proposdm9lo ►eF Me I i r„ Existing House V-11 1 Existing 1 1 1 i Driveway CI R_ �• a-, �I � 1 of Gap a1 I � °, Existing Shop 1 Powerpole i I = I a 1 I 95, --------7'roperlyl_in�—e----------- � I . O 1 I I Fire Hydrant(FH) I � I � Scale: 'I"=30' � � I � I I ' I I � I . � I I MINIMUM SKETCH REQUIREMENTS(Put"N/A"if Not Applicable): North arrow Property lines &dimension Slope of property Street &street name(s) Existing building,structures Utility&street light poles Proposed work Existing curb or edge Trees Existing S/W or of pavement Existing utility locations D/W apron (sewer,water,storm) PUBLIC FACILITY IMPROVEMENT PERMIT City ofTigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 4 of4 Page 84 2011 Edition Stationary Lane Closure with Flagging Diagram 320 Diagram 320 covers total closure of one lane of a two-lane, two-way roadway. See the detail inset for the layout if using a single flagger to control both directions of traffic on low volume roads (less than 400 ADT)with good sight distance as discussed below. 1. Use truck-mounted flashing warning lights on work and protection vehicles. See Section 4.3— Lights and Lighted Signs for exceptions. 2. For added visibility, a truck-mounted arrow board or PCMS in caution mode may be used. 3. Flaggers at each approach are required if any of the following conditions exist: a. Night Operations. b. Work space is over 200 feet in length. c. Sight distance is less than 750 feet from each approach through the lane closure. d. Traffic volumes are greater than 400 ADT. 4. The length between the Flagger Ahead signs shall not exceed one mile. Use Diagram 340—Lane Closure with Pilot Car if exceeding one mile. 5. Cones should be used to outline the work space when curves or other roadway alignments prevent clear direction for the motorists to pass the work space safely. 6. Cones along the work space are recommended when posted speeds are 45 mph or greater, when working under heavy traffic or when travel lanes are narrower than 11 feet. 7. Extended queue signing (see Diagram 5-4) should be used when traffic queues extend beyond the initial advance warning sign. 8. When flagging near an intersection, the "Flagger Ahead" (CW23-2) sign should be visible to traffic entering from any side road. Additional advance warning and Flagger Ahead symbol signs may be placed on the side road(s). 9. Sign set-up and flagger placement shown may be used for intermittent full road closures of 20 minutes or less. 10. The "ONE LANE ROAD AHEAD" (W20-4) sign is optional and should be considered on high volume or high speed roads, or when extended queues are expected. Chapter 5 December 2011 p (nom --------- C/) No 0 a a i Single Flag er Operation ,�,� °.�', cr ! for Low-Volumes N (Optional) o a 0 o cWi, o D N m I (�T � m �"° M 0 0 0 o d o I I BE RAOGER I PREPARED ONE LANE WROAD Q WAHEAD i A: H !►c: 1 TO STOP r 0 0 0 m I — — —• •T• — — — I • ROAD CD I ♦ ® •• ♦ I WORK o W 'o 100-1 3 I i c 1 s K s i A I--I I AHEAD 0 0 0 I �-- I 0 y I w 4 I y NW - 1 ro 1 N N J C 1 inn 1 � 1 • A B B m, i ---------------------i 1+ 1 mile _I � TI Max. sv cc (Q B Buffer Protection Vehicle ROAD • w/TMA(both Optional) WORK See Chapter 4 _0 AHEAD BE ONE LANE AD sroP Two Flagger Operation 7 w M CD 00 (Optional) p Cn 12569 LIGHTING LEGEND �Q (UNLESS OTHERWISE SPECIFIED) INSTALL 1-W AL-TX ST LT CIRCUIT IN 1-3"SCH40 PVC • P • CONDUIT,PROVIDED & INSTALLED BY PGE CONTRACTOR INSTALL 1-#10 CU-TX ST LT CIRCUIT IN 1-1" or 1-2" SCH40 PVC A 50 D ______ 3000 ���� CONDUIT,PROVIDED & INSTALLED BY PGE CONTRACTOR Q- tiy�G Q PGE CONTRACTOR INSTALLED 1730 SECONDARY VAULT ''� '�i✓ti 11/0333 /� i♦ VT 2 Ty 30'4�-V1-1 1997 ♦ ♦ ♦ D-1305 ♦ N ♦ ♦♦ 12598 ♦ ♦ ♦ gY CONSTRUCTION NOTES: SLCST •. P ♦ Ss WU Q ' ♦♦ fY u2j'Q _ 1. CUSTOMER TO PROVIDE ALL TRENCHING,BACKFILLING,CONDUIT,ELBOWS,JUNCTION 920 rrQ CUT+ ♦♦♦ !;2 CiZ 1-048 LU U = BOXES,8 INCHES D EP AND 30DS.JNT USE TRENCH WTH GAS TRENCH TO INCHOEIS WIDE,MEASUREDI FROM NAL GRA EBE CZ 7-0J _j LLJU M }Q 2. A PGE STANDBY CREW IS REQUIRED FOR OPENING ALL ENERGIZED PGE VAULTS, ♦ 92 -J U §� JUNCTION BOXES,AND EQUIPMENT/FACILITIES,INCLUDING CONNECTION OR INSTALLATION ♦ IU =Y fr OF CONDUITS AND PULL STRINGS.CALL SERVICE COORDINATION AT 503-323-6700 ` Y•N st TO SCHEDULE A PGE STANDBY CREW. ♦ I 3. ALL PGE CONDUCTORS TO BE INSTALLED IN GRAY,SCHEDULE 40,ELECTRICAL VJ s ♦ j GRADE,PVC CONDUIT WITH NYLON PULL STRINGS TIN.500 LBS.TEST)PGE TO DETERMINE TE SIZE AND NUMBER OF CO . �o �y0 ♦ MAINTAIN 12 VERTICAH INCHES AND 24 HORIZONTAL INCHES CLEARANCE BETWEEN Q ��l ♦♦ GAS AND OTHER UTILITIES. ALL ELBOWS 4 INCH&SMALLER TO BE 36 INCH RADIUS. RIGFOR RUNS OF 0+ 415' ♦ 1151 FEET ORD STEELOLONGER,OR FOR ANYPGE APPROVEDBERGLASS LENGTH RBUN ENDS WITH MOREARE THAN HIAND180 DEGREES e� IN BENDS.PVC SCHEDULE 40 BENDS ARE ACCEPTABLE FOR RUNS OF 150 FEET R JI., LESS.THE MAXIMUM TOTAL BENDS IN ANY CONDUIT RUN IS 270 DEGREES.ALL V BENDS MUST BE FACTORY MADE.REFER TO LETTER OF RESPONSIBILITY FOR ^o FURTHER DETAILS, 4. ALL CONCRETE FOOTINGS NEED TO BE INSTALLED WITH TOP OF BASE FLUSH TO CURB 1 SIDEWALK. �y`r • . .F 5. CUSTOMER RESPONSIBLE FOR ROAD CROSSINGS. ALL CROSSINGS MUST EXTEND FROM PROPERTY LINE TO PROPERTY LINE. CROSSINGS TO BE 48 INCHES DEEP, (4 ` MEASURED FROM FINAL GRADE. VT-273 ` 6. DIRECTIONAL BORING REQUIREMENTS.BLACK HDPE (HIGH DENSITY POLYETHYLENQ DUCT (I _� OR SCHEDULE 40 PVC WITH A MECHANICAL CONNECTION (CERTA-LOK OR LIKE MECHANICAL CONNECTION PRODUCT) AS AN ALTERNATIVE TO HDPE DUCT.HDPE SHALL MEET THE 162 1 20' REQUIREMENTS OF PGE SPECIFICATION LC20515 (AVAILABLE ON REQUEST FROM PGE PROJECT 30'-UNKNOWN MANAGER .FOR SAFETY REASONS THE DUCT SHALL BE BLACK WITH THREE EQUALLY SPACE 1997 EXTRUDED ED STRIPES (WHICH IS A SPECIFICATION REQUIREMENT) MANDREL TEST OF HDPE PIPE IS REQUIRED AFTER INSTALLATION WITH PGE INSPECTOR PRESENT. 7. TRANSFORMER PADS ARE TO BE SET SO THAT THE TOP IS 2 INCHES ABOVE FINAL GRADE. CONDUIT IS TO BE INSTALLED IN PAD AS INDICATED IN DETAIL AND TO EXTEND 1 INCH ABOVE THE PAD. �j 8. ALL PGE TRANSFORMERS TO BE INSTALLED 8 FEET (MIN FROM ANY COMBUSTIBLE BUILDING,WALL OR OVERHANG AND 4 FEET (MIN FROM ANY FIRE HYDRANT. J� PGE TRANSFORMERS MUST BE WITHIN 15 FEET OF A DRIVEABLE AREA. Q ALWAYS MAINTAIN 10 FEET CLEARANCE IN FRONT OF ALL TRANSFORMERS. 12626 9. STEEL BARRIER POSTS ARE REQUIRED AROUND TRANSFORMERS THAT ARE EXPOSED TO VEHICLES, 10.AS NEEDED-FRONT LOT PUBLIC UTILITY EASEMENT (P.U.EJ TO BE 8 FEET (MIN , 10 FEET (PREFERRED) . 11.CONSULT WITH PGE REPRESENTATIVE 2 WEEKS BEFORE STARTING MAIN POWER TRENCHING FOR A PRECONSTRUCTION CONFERENCE. INCLUDED IN THIS CONFERENCE Q" WILL BE EXCAVATOR,PGE,TELCO,GAN,AND GAS. P� 12.CUSTOMER TRENCH AND ELBOW CONFIGURATIONS,ALL CONDUIT,VAULT AND PAD INSTALLATIONS MUST BE INSPECTED BY PGE PRIOR TO BACKFILLING.WHEN YOU ARE READY FOR PGE TO INSPECT (AFTER INSTALLATI^)'r IS COMPLETE) CALL 503-736-5450 OR 503-463-4348 (SALEM AR ALLOW UP TO 2 RKING DAY FOR INSPECTION TO OCCUR REFER TO THE PGE ELECTRIC SERVICE REQUIREMENTS BOOKLET FOR SPECIFIC REQUIREMENTS. JUNCTION BOX INSTALLATIONS 13.DESIGN IS BASED ON STANDARD UNDERGROUND EQUIPMENT.NON-STANDARD UNDER- CONTACT SERVICE COORDINATOR GROUND EQUIPMENT MAY BE AN OPTION AT AN ADDITIONAL COST TO THE CUSTOMER. FOR STREET LIGHTING FOR TRENCH AND CONDUIT INSPECTION PRIOR CONTACT PGE FOR APPROVED MANUFACTURERS TO BACKFILL.PGE WILL NOT INSTALL WIRE INSTALL 30AMP FUSES IN SECONDARY PEDESTALS OR SECONDARY ANY DEVIATION FROM THIS DESIGN MUST CH FINAL GRADE IF HARD SURFACE(FLUSH) UNSE TRENCH JS 100 BACTFItLFD S7 ELET LIVAUTS GHT PERE T&D HICHEVR IS ST LICON RUCTIONA STANDARPOINT OF ATTCHMENT'D LC-FOR-115 0 BE APPROVED BY PGE PROJECT MANAGER PGE CONSTRUCTION DRAWING SERVICE COORDINATOR FINAL GRADE IF SOFT SURFACE 503 323-6700 OR 800 542-8818(SALEM) "GROUND RUp 13"x24"x18"DEEP OR DATE: 12/I1r1018 SCALE: NTS ACCOUNT: 5960001 AWO: 3000000689 JOB NO.M2641786 uvsT'LLEDsv 17`x30'xl8"DEEP RIGHT-OF-WAY PERMIT NOTICE: CUSTOMER ,✓ PGE APPROVED TITLE 1 JUNCTION BOX Road Side 24" Spoil A PERMIT FROM THE LOCAL JURISDICTION IS REQUIRED BEFORE ANY I DETERMINED BY PGE -4—Typical WORK IN THE RIGHT-OF-WAY MAY BE PERFORMED. ONLY PGE APPROVED PGE POLE 38"RADIUS 9AEN[r CONTRACTORS AND CONTRACTORS WHO HAVE MADE OTHER SPECIAL CIRCUIT SIZE t"PVC SCH 40 ELECTRICAL GRAI LEGEND AGREEMENTS WITH PGE WILL BE ALLOWED TO WORK UNDER PGE'S PERMIT MURRAYHILL — KINTON 17x77 TO OPTIONAL ST LT POLE THE CONTRACTOR MUST NOTIFY THE LOCAL JURISDICTION 48 HOURS 11PGE 30" O PGE Primary/ BEFORE WORK IS TO BEGIN. A COPY OF THE PERMIT MUST BE ON SITE. LOCATION 36" Min Secondary Cable Min Cover Inside Duct 14595 SW HORIZON BLVD, TIGARD, OR 97229 Trench 2"OR 3"PVC SCH 40 'SCH 40 GREY PVC FACTORY BENDS O Telco/CATV (STEEL OR PGE APPROVED FIBERGLASS CALL 811 BEFORE YOU DIG ELECTRICAL GRADE ATTENTION: DESCRIPTION (DETERMINED BY PGE, FOR RUNS OVER 15D'.OR 180 DEGREES OR MORE IN BENDS) ®Backfill OREGON LAW REQUIRES YOU TO FOLLOW RULES ADOPTED , 10" INSTALL W AL-TX ST LT CIRCUIT IN 2`CONDUIT FROM XFORMER 50 55100 TO ST LT POLE C21048-162 TOP VIEW 6"OF COMPACTED • BY THE OREGON UTILITY NOTIFICATION CENTER. ST—FT-IOr 3/4'MINUS BACKFILL Select Backfill THINK THOSE RULES ARE SET FORTH IN OAR 952-001-0010 , COUNTY SECTION(S) WORK WITH SHEET AROUND AND LS'T-IR IT To UNDER SPLICE BOX Undisturbed THROUGH 952-0O1-0090.YOU MAY OBTAIN COPIES OF WASHINGTON C21-04B uGHT vol r I?" Min SAFETY THE RULES BY CALLING THE OREGON UTILITY BEAVERTON 1 OF1 NDUIEarth NOTIFICATION CENTER ADMINISTRATION 503-232-1987 LINE CREW CENTER3 FIS @ ( IDESIGN 8Y PHONE(503) DRAWN BY UIT •INSTALL GRGUND ROD ANC �\���G ouNDCONDUITONTHESOURCESIDE joint Use Trench W0 Gat TO REQUEST UTILITY LOCATES CALL THE OREGON 2213 SW 153RD DR JASON MORIN 672-5474 PENKA TANTILOVA ROD 1 UTILITY NOTIFICATION CENTER,811 AT LEAST Know whaYs below. BEAVERTON,OR 97006 2 BUSINESS DAYS PRIOR TO EXCAVATION. Call before you dig. Q PORTLAND GENERAL ELECTRIC CO.-ALL RIGHTS RESERVED