Permit (17) CITY OF TIGARD MECHANICAL PERMIT I COMMUNITY DEVELOPMENT Permit#: MEC2018-00994 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 01/07/2019 T I[. r4li i.7 g Parcel: 2S113BA02300 Jurisdiction: Tigard Site address: 7560 SW DURHAM RD Project: PWCC Subdivision: 2017-013 PARTITION PLAT Lot: 2 Project Description: Adding(4)RTU's with all ducting and grills,exhaust fan venting,(1)ductless split system for IT room,and gas piping. Contractor: PROTEMP ASSOCIATES INC Owner: MISSION HOMES NORTHWEST LLC 9788 SE 17TH AVE PO BOX 1689 PORTLAND, OR 97222 LAKE OSWEGO, OR 97035 PHONE: 503-233-6911 PHONE: FAX: 503-238-9767 FEES Specifics: Description Date Amount Type of Use: COM Permit Fee 01/07/2019 $2,185.41 Class of Work: ALT Type of Const: VB Plan Review 01/07/2019 $546.35 Occupancy Grp: B Occupancy Load: 12%State Surcharge-Mechanical 01/07/2019 $262.25 Stories: 1 Info Process/Archiving-Lg$2.00(over 01/07/2019 $6.00 11x17) Project Valuation: $83,000.00 Info Process/Archiving-Sm$0.50(up to 01/07/2019 $11.50 11x17) Fuel Air Handlers Fuel Types: Natural Gas Units<10000 cfm: Gas Pressure: Units>10000 cfm: Furnaces Boilers&Compressors Furnaces<100K BTU: 0-3 HP: Furnaces>=100K BTU: 3-15 HP: Floor Fumaces: 15-30 HP: Unit Heaters: 30-50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: Heat Pump: 1 Appliances Vent Fans: 3 Vent Systems: Total $3,011.51 Hoods: Comm Incinerators: Woodstoves: Gas Fireplaces: Required Items and Reports(Conditions) Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc: Duct Work: 1 Fire/Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling :3.232.1987 or 1 :00.332.2344. Issued By: IP � +�� Permittee Signature: L Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Mechanical Permit Application rOR Orrlce I S1: OM.v City of Tigard eceived tt III . .1 13125 SW Hall Blvd.,Tigard,OR 97223 Date/By:�� //r i 1 ������� g y Phone: 503.718.2439 Fax: 503.598.1960 DEC 2 2 G 1$ Plan Review ) �j�� Date/By: �1 �2/�— 2`X/ T I G A R D Inspection Line: 503.639.4175 Date Ready/By: uns: ® See Pae or Internet: www.ti and-or. ov CITY Ci' -�;G9 ARS? Notified/Method g g o Nohfied/Method. /� Supplemental Information BUILDING DIVi I� I ��d�'H TYPE<C?It BYO ,%%�� t .i t al mow,5 `'08E-olicialsr Mechanical permit fees*are based on the value of the work o New construction ®Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition 0 Other: mechanical materials,equipment,labor,overhead,and profit. Value:$, $83,000.00 CA,, , R>014+CO 1 t5I Ni*L VM YST1IMSnEs* ❑ 1-and 2-family dwelling ./ Commercial/industrial 0 Accessory building For special information use checklist. ❑Multi-family 0 Master builder 0 Other: Description I Qty. I Ea. I Total Heating/cooling: ,I(I1E1;;',5) (��tlf9�' 41�AJ+ 3 �. "��1I�;- - Air conditioning 46.75 Job site address:7560 SW Durham Rd Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP:Tigard Oregon 97224 Furnace 100,000+BTU(ducts/vents) 54.91 Heat pump 61.06 Suite/bldg./apt.no.: 1 Project name:PWCC Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Subdivision: I Lot no.: Other: 23.32 Other fuel appliances: Tax map/parcel no.: Water heater 23.32 31 SC MION O Gas fireplace/insert 33.39 OF Wlllw. Flue vent for water heater or gas 4-RTU's with all ducting and grills, Exhaust fan with venting,1-ductless fireplace 23.32 split system for IT room,gas piping Log lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 r23.32 Other: El PR E ri.-V k?lYll " I , , ,�1 , ;! , Environmental exhaust and ventilation: Name: Range hood/other kitchen equipment 33.39 Address: Clothes dryer exhaust 33.39 City/State/ZIP: Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 23.32 Phone:( ) Fax:( ) Attic/crawlspace fans 23.32 ' I,AtilLiCA 1T f Co 1TA `PEI 1 Other: 23.32 Fuel piping: Business name: $14.15 for first four;$4.03 for each additional Contact name:Bruce Butner Furnace,etc. Address: Gas heat pump Wall/suspended/unit heater City/State/ZIP:Same as below Water heater Phone:( ) Fax::( ) Fireplace Range E-mail:brute@protmp.com Barbecue ,.. . Clothes dryer(gas) Business name:Protemp Associates Other: 140114,1416i?E MJT*Eli! Address:9788 Se 17th ave Subtotal City/State/ZIP:Portland Oregon 97222 Minimum permit fee($90.00) Phone:(503)519-6199 Fax:(503)238-9767 Plan review(25%of permit fee) State surcharge(12%of permit fee) CCB lit.:38868 TOTAL PERMIT FEE This permit application expires if a permit is not obtained within 180 �s7 days after it has been accepted as complete. Authorized signature: ,_ l /. -7 * Fee methodology set by Tri-County Building Industry Service Board Print name:Bruce Butner JAL! 'Date:12/18/18 I:\Building\Pennits\MEC_PermitApp_040113.doc 440.46177(11/02/COM/WEB) City of Tigard Tel: 503.718.2439 Location: Inspection Date: 7560 SW DURHAM RD, TIGARD, OR, 97224 Record Type: Record ID: Commercial - Mechanical MEC2018-00994 Inspection Type: Inspector: 699 Mechanical final Jeff Grove Result: PASS - NoCofO Comments: Violation Summary: Inspector Contractor