Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (30)
lk-c qot0 C DEC 10 2018 4DHP SINGLE-ZONE CITY OF TIGARD UP TO 24.5 SEER PRODUCT SPECIFICATIONIP. TLESS HEAT PUMP FORM NO.4DHPSINGLE-100(11/2016) OUTDOOR UNITS 4DHP SINGLE ZONE • 9K/12K/18K/24K/30K/36K/48K • Mid Efficiency(15.5-24.5 SEER) .i. • Matches with all indoor units • Variable Capacity Rotary Compressor • DC Inverter Control • Electronic Expansion Valve(EEV) • Operates down to-13 F 3 TON&UNDER 4 TON INDOOR UNITS DWM WALL MOUNTED • 9KL/12KL/9K/12K/18K/24K/30K • Pre-Heat Fucntion • LED Readout CEILING CASSETTE • 9K/12K/18K/24K/36K/48K ) • Pre-Heat Fucntion • Built-In Condensate Pump • Grille Sold Seperately • CAT#1.861054 • CAT#1.861055 DUCTED UNIT , . • 9K/12K/18K/24K/36K/48K • Medium Static Slim Ducts • Built-In Condensate Pump slim CERTIFIED. coo. Intertek Page 1 SINGLE-ZONEHEAT PUMP SYSTEMS MIN-S LI S FEATURES AND BENEFITS OUTDOOR UNITS • • Three Speed Fan • Equipment Warranty:5 year parts,7 year compressor • Air Filter • SEER up to 24.5 • HSPF up to 10.5 • 0.75 through 4 ton • Single phase power supply(115V and 208/230V) • R410A Refrigerant • Outdoor Coil:Aluminum fins fitted to copper tubes • Wire grille guard provided • Variable Frequency Rotarty Compressor • Compressor Crankcase Heater • DC Inverter Control • Inverter module protection • electronic expansion valve • Compressor overcurrent protection • Condenser high temperature protection • Compressor discharge temperature protection • Voltage protection • Terminal Strip • Defrost contorl • 4-way interchange reversing valve INDOOR UNITS-WALL-MOUNTED • Pre-Heat Function • LED Readout • Auto Restart • Cooling Override • Flare Connections • Multi-Refrigerant Outlet • Three Speed Fan INDOOR UNITS- CASSETTE UNITS • 360°Airflow Panel • Pre-Heat Function • LED Readout/Infared Receiver Panel • Auto Restart • Cooling Overide • Built-In Condensate Pump • Compact Design • Flare Connections • Four Speed Fan • Turbo Fan with Backward Curved Blades • Air Filter • The cassette panel must be ordered seperatley.See Specifications table for ordering information. INDOOR UNITS- MEDIUM STATIC DUCTED • Pre-Heat Function • LED Readout Panel • Auto Restart • Cooling Override • Built-In Condensate Pump • Duct Connections • Flare Connections Page 2 • S1NGLE-ZONF HEAT PUMP SYSTEMS MINPSPLITS MODEL NUMBER GUIDE OUTDOOR SINGLE-ZONE HEAT PUMP UNITS 4 D HP 1 S 09 S -1 P REFRIGERANT TYPE `VOLTAGE R410A L=115V-1 PHASE-60HZ P=208/230-1 PHASE-60HZ SERIES TYPE D=DUCTLESS MINOR DESIGN SEQUENCE 1=1ST REVISION UNIT TYPE HP=HEAT PUMP REFRIGERANT CIRCUITS S=SINGLE CIRCUITS MAJOR DESIGN SEQUENCE M=MULTIPLE CIRCUITS 1=1ST GENERATION 2=2ND GENERATION NOMINAL COOLING CAPACITY 09=.75 TONS 30=2.5 TONS COOLING CAPACITY 12=1 TONS 36=3 TONS B=BASIC EFFICIENCY 18=1.5 TONS 48=4 TONS S=STANDARD EFFICIENCY 24=2 TONS H=HIGH EFFICIENCY WALL-MOUNTED INDOOR UNITS DWM1O9S4 -1P SERIES TYPE JT - `VOLTAGE D=DUCTLESS SYSTEM L=115V-1 PHASE-60HZ P=208/230-1 PHASE-60HZ UNIT TYPE WM=WALL MOUNT MINOR DESIGN SEQUENCE 1=1ST REVISION MAJOR DESIGN SEQUENCE 1=1ST GENERATION REFRIGERANT TYPE 2=2ND GENERATION 4=R410A NOMINAL COOLING CAPACITY COOLING EFFICIENCY 09=.75 TONS S=STANDARD EFFICIENCY 12=1 TONS 18=1.5 TONS 24=2 TONS 30=2.5 TONS CASSETTE INDOOR UNITS D22C109S4_ -1 P SERIES TYPE J L VOLTAGE D=DUCTLESS SYSTEM L=115V-1 PHASE-60HZ P=208/230-1 PHASE-60HZ UNIT TYPE 22C=2X2 CASSETTE NON-DUCTED UNIT MINOR DESIGN SEQUENCE 33C=3X3 CASSETTE NON-DUCTED UNIT 1=1ST REVISION MAJOR DESIGN SEQUENCE REFRIGERANT TYPE 1=1ST GENERATION 4-R410A 2=2ND GENERATION COOLING EFFICIENCY NOMINAL COOLING CAPACITY S=STANDARD EFFICIENCY 09=.75 TONS 12=1 TONS 18=1.5 TONS 24=2 TONS 30=2.5 TONS 48=4 TONS Page 3 SNCL -ZONA HEAD.. PUMP SYSTEMS MINI-SPLITS DUCTED INDOOR UNITS DMD112S4_ -1P SERIES TYPE J L VOLTAGE D=DUCTLESS SYSTEM L=115V-1 PHASE-60HZ P=208/230-1 PHASE-60HZ UNIT TYPE MD=MEDIDUM STATIC DUCTED MINOR DESIGN SEQUENCE 1=1ST REVISION MAJOR DESIGN SEQUENCE 1=1ST GENERATION REFRIGERANT TYPE 2=2ND GENERATION 4=R410A NOMINAL COOLING CAPACITY COOLING EFFICIENCY 09=.75 TONS S=STANDARD EFFICIENCY 12=1 TONS 18=1.5 TONS 24=2 TONS 30=2.5 TONS 48=4 TONS Page 4 SINGLE-ZONE HEAT PUMP SYSTEMS MIN - LITS DIMENSIONS-OUTDOOR UNITS- INCHES(MM) 4DHP1SO9S,4DHP1S12S 2-1/2(64) 31-7/8(809) . 21-5/8(549) 1--lat, ( -r-----4--f t J V/ F ; ' cn c- ‘.-- TOP VIEW i _,. . , -............. -.- k Il . ..____.._.__._.. 22 07---1-=1i-1:IS--g.----711 (559) 1 IMMIII. =2::1 - .1---ME : .:?:.1-=.i vi 0 I III amili A INMinimommonew' . --- — — --- -IIIr FRONT VIEW SIDE VIEW 4DHP1S18S 1 33-1/4(845) - -0-2-7/8(73) 22(559) r ---- C 1 —. c) , C\I `- `-- ...=.; _ . TOP VIEW • • . 1 . i ,-- - ----------z_-.---_,..-.-_-=- -m-7- :,,,E--E--,,F7'.:.--:--=-:' '''''''- '-...:,47--:•1 17.71' E.,--"E•E..-- ,:-.:.,_-, E=-17.4. - --- -- • 27-1/2 (699) 4. 'N., imi 1 I ' IIII•..--,:f..- ..... FRONT VIEW SIDE VIEW S1NGLE-ZONE HEAT PUMP SYSTEMS MINI-SPLITS ' DIMENSIONS-OUTDOOR UNITS- INCHES(MM) 4DHP1S24S,4DHP1S3OS,4DHP1S36S -.. 37-1/4 (946) I.- —3-3/8 (86) -0— 25-1/4 (641) --D- rat A 4- A s.? ttl I CTO' iro c0 c.-3 CO •,:i- 15-1/2 0 (0 IC) I - 1, TOP VIEW - --------- : igith‘..ii . 31-7/8 • NV (810) _ . ' ..•-• • ........_2...... .......... .11..m.1 .......1• • FRONT VIEW SIDE VIEW Page 6 SINGLE-ZONE HEAT PUMP SYSTEN1S MINI-SPL_ITS DIMENSIONS-OUTDOOR UNITS-INCHES(MM) 4DHP1S48S MPA048S4S 25 (635) ;IL_ 1011 15-3/8 14-1/2 j 16 (391) (369) (406) 6 r 36-7/8 (937) -0- 3-3/8 TOP VIEW (86) • ..IIIIIIIII�.... nllll...� Jllllflll. 1111111!!::.:;!!!I III111111!IIIIiiizi''1:!IIIIIII 11M1111111101111111111111111110111 �. I!111111111111111111,. 111111111111101 T111111111111111P;;I;II: 111111111111111,!!II II IIIIIII!l11111;lli;r4;111111111111!lli!11' 111911'-1111111'111!!!!'!"iii!II111111111i'ii IIT!!'111111!IIIIIIIIIIIi:.IIIIII11111Pill illi!!;IIIII!IIIIIIIIIIIIIIIIII11HIP,siIi" \'li i!!II9111111111111111111!'iiilllllll' \SII 11111:1 ::......... :'jiIIIIIIIIlId 53-3/4 (1365) °111111111•1- '•"11111 IIIIIIIII°',I 1111111111!;11111111111111111111111i;111111111 1111 IIIIIIIIIII11111111!11 1 IIIIil11011111 n'g111111111111111111111, 111111111111`41 T11!ii u111111:11, 11:'1 11i1111111111'i!' 11111P1111!:111V:11111111111111111111 iilllf'!11111111111"11;i1111111111111111,;i Iii!1!1111111111111111iniii1111111111111 11 11111„!911111111111IIi9111111111111111%1111 !II\ 111111 '.!g1111111111111111191111111111111 �nnllnll: 11unf1ullo 11 FRONT VIEW SIDE VIEW Page 7 SN Z( HEA PUMP SYSTEMS MINI-SPLITS DIMENSIONS-WALL MOUNTED INDOOR UNITS- INCHES(MM) DWM109S4,DWM112S4,DWM118S4,DWM124S4,DWM130S4 > 0 1 1 1 - 1 TOP VIEW ] , B h-- - RICE11111 ----] - f C SIDE VIEW SIDE VIEW r A - \ ff Iff/MIMENME I Nffil " [D BOTTOM VIEW A B C D SIZE IN. MM IN. MM IN. MM IN. MM 009,012 32-7/8 835 11 279 29-1/4 743 7-7/8 200 018 39 991 12-3/8 314 34-3/4 883 8-5/8 219 024,030 46-3/4 1187 13-1/2 343 42-1/2 1080 10-1/4 260 Page 8 ' SIN _ -Z iJ HE—AT PU - DIMENSIONS-WALL MOUNTED INDOOR UNITS- INCHES(MM) DWM1O9S4,DWM112S4 4-3/8 Indoor unit (111) outline 5-1/2 (140)-0- -4.1-- — e__, Il r� . ! to oI:.% i IT.IN1 1-3/4 (44) !I 0 I T , 1-3/4 (44) 32-7/8 (835) Left rear side 1-3/8 Right rear side refrigerant pipe inlet (35) refrigerant pipe inlet 2-1/2 (64) diameter 2-1/2 (64) diameter DWM118S4 7/8 (22) Indoor unit outline ----/ 9.2 i, I k � M • -d- —I— -'• • rii Ili 1-3/4 (45) Ho- 10-1/4 (260) 5 1/4 133 Left rear side 39 (991) Right rear side refrigerant pipe inlet refrigerant pipe inlet 2-1/2 (64) diameter 2-1/2 (64)diameter DWM124S4,DWM13OS4 Indoor unit 10-1/8 10-7/8 outline (257) (276) Ia e ii I I e 46-3/4 (1187) 1-3/4 (44) Left rear side refrigerant pipe inlet 7/8 (22) Right rear side 2-1/2 (64)diameter refrigerant pipe inlet 2-1/2 (64) diameter Page 9 SINlLE-?ONE HEAT PUMP SYSTEMS MINESPL1TS DIMENSIONS-CASSETTE INDOOR UNITS- INCHES(MM) DRAIN • • • CONNECTION FRESH AIR GAS _—____—.----4 INTAKE PIPE 01:-2-1/2 In.(64 mm) / 0 Diameter LIQUID PIPE SIDE VIEW 10-3/8 (264) MIMI � , _• --- \G 1 1,, opplfimmuilli -;:kg-' 22-112 ° 1� 0-5/ (572) s 1 j (§). :1t..0 LEFT SIDE VIEW 21-1/2(546) RIGHT SIDE VIEW 22-1/2(572) BOTTOM VIEW(Body) INSTALLATION----- HANGERS HANGERS LEVELING ADJUSTMENT-----"— NUT(4) CEILING �....... � AIR a / °' . ,AIR OUTLET AIR OUTLET DIFFUSER PANEL INLET -0-- - 23-5/8(600) _ (Ceiling Opening) SIDE VIEW Firl.--- 1111110010iiiii [ 1 111110111 I (648) il 111111111111 41111,karri.1-11 is 25-1/2(648) r BOTTOM VIEW(Panel) Page 10 SINGLE ;N HEAT T P-UM ' SYSTEMS P ITS DIMENSIONS-CASSETTE INDOOR UNITS-INCHES(MM) D33C124S4,D33C136S4,D33C148S4 r GAS PIPE\r.:� l • /O LIQUID/ J � PIPE flO • • • „„, 030-3/4 T (781) 33-1/8 (841) FRESH AIR INTAKE Diameter OF ► DRAIN CONNECTION LEFT SIDE VIEW RIGHT SIDE VIEW 26-3/4(679) 33-1/8(841) BOTTOM VIEW(Body) A SIZE IN. MM 024 8-1/8 206 / - 036 9-5/8 244 AIR Y / 4 AIR 048 11-1/4 286 OUTLET DIFFUSER AIR OUTLET PANEL INLET SIDE VIEW A 37-3/8 = ======== (949) = - _______- - -------- - -------- =7: r / 37-3/8(949) BOTTOM VIEW(Panel) Page 1' SINGLE-ZONE HEAT PUMP SYSTEMS MINI-SPLITS DIMENSIONS-MEDIUM STATIC DUCTED INDOOR UNITS- INCHES(MM) MOUNTING ELECTRICAL LUGS( —''--- CONTROL \ 'E t BOX TJ p P 1 1(25) 1(25) t I. •1 +3/4(19) 314(19)- - + FRESH AIR INTAKE N 3-5/8(92)Diameter(015 thru 018) 5(127)Diameter(024 thru 048) MOUNTING TOP VIEW LUGS(4) + 4 SUPPLY AIR NISI I J OPENING B D --► F -0 G E SIDE VIEW FRONT VIEW ). .) �l///LIPIPED E al--•-•`"' �PIPE El b DRAIN CONNECTION '•}:•::gg•:•.•:S•:•J:✓.•:: i in:SSv.•:•.❖d:•:S•d.•:❖.ov •:%K _.. E OPTIONAL BOTTON Iiiiiiiiiiiittinf 1 H ;:;RETURN AIR OPENING }:::3, j .......-.:..-...................:...:•'•':..:...............:............... ' �\ AIR FILTER • ELECTRICAL M I CONTROL 1 BOX BOTTOM VIEW ,11 :RETURN AIR;:$:::••:::::J:S::::':;:;:$;✓: OPENING 3 I::.:: 1::.:o•.•.•.:,4• ..,.........,......:..........:.....:...,..............._...:.......:...:..: III . - K - 1 ---AIR-FILTER .... REAR VIEW A B C D E F G H SIZE IN. MM IN. MM IN. MM IN. MM IN. MM IN. MM IN. MM IN. MM 009 thru 012 27-5/8 702 8-1/4 210 25 635 22-1/2 572 31-1/8 791 2-5/8 67 19-1/2 495 1-3/8 35 018 36-1/4 921 8-1/4 210 25 635 22-1/2 572 39-3/4 1010 2-5/8 67 28 711 1-3/8 35 024 36 1/4 921 10-5/8 270 25 635 22-1/2 572 39-3/4 1010 2-5/8 67 28 711 1-3/8 35 036 44-7/8 1140 10-5/8 270 30-1/2 775 28 711 48-1/2 1232 2-5/8 67 36-3/4 933 1-3/8 35 048 47-1/4 1200 11-7/8 302 34-1/8 867 31-1/2 800 50-3/4 1289 3-1/8 79 38-1/8 968 1-1/2 38 J K L M N P SIZE IN. MM IN. MM IN. MM IN. MM IN. MM IN. MM 009 thru 012 4-5/8 117 23 1/2 597 7 7/8 200 3-1/8 79 29-1/8 740 13-3/4 349 018 4-5/8 117 32 813 7-7/8 200 3-1/8 79 37-3/4 959 13-3/4 349 024 7 178 32 813 10-1/4 260 3/4 19 37-3/4 959 13-3/4 349 036 7 178 40-3/4 1035 10-1/4 260 3/4 19 46-1/2 1181 19-1/4 489 048 8 203 43 1092 11-3/8 289 1-3/4 44 48 7/8 1241 19-5/8 498 "age 12 SINGLE-ZONE HE"---0. Poe°iP SsYSTEMS MINI-SPLITS OUTDOOR SPECIFICATIONS -I -I a a a a a a a to N ti) 47 ch th 41 ci) N 03 V 0 to CO MODEL NUMBER iinn y 0 a a N 01 In H a a a a a a a a a O O a 0 a O O 0 0 Nr v v v v a a NI. v NOMINAL SIZE-TONS 0./51 0.75 1 1.5 2 2.5 3 4 AMBIENT TEMP. COOLING 5-122 OPERATING RANGE-°F HEATING -13-86 SOUND DATA DB(A) 56 58 56 58 60 61 59 66 63 CHARGE FURNISHED (R410A)-OZ. 38.8 40.6 38.8 40.6 68.8 82.9 106 108 148.2 REFRIGERANT MAX LINE LENGTH-FT. 25 CHARGE REQUIRED/ ADDITIONAL FT.-OZ. 0.16 0.32 TYPE Rotary REFRIGERANT OIL TYPE Ester Oil VG74 COMPRESSOR REFRIGERANT OIL CHARGE-OZ. 12.5 15.2 27.7 361 36.1 47.3 LOW AMBIENT CUT-OFF -13°F LIQUID/GAS PIPE 1/4"/3/8" 1/4"/1/2" 1/4"/3/8" 1/4"/1/2" 1/4"/1/2" 3/8"/5/8" 3/8"/5/8" 3/8"/5/8" 3/8"/5/8" (FLARE) MAXIMUM REFRIGERANT CONNECTIONS-IN. PIPE LENGTH-FT. 98 164 213 MAX.DIFFERENCE IN LEVEL OF INDOOR UNIT 40 40 40 40 66 82 82 98 98 -FT. (NO.)DIAMETER-IN. (1)-16.5 (1)-18 (1)-22 (2)-20 OUTDOOR FAN TOTAL AIR VOLUME- 1180 1180 1120 1180 1470 2355 2530 2940 4240 CRPM 850 850 800 800 800 850/750/700 950/800/750 950 960 NUMBER OF ROWS 2 3 2.6 2.6 2.6 2 FINS PER INCH 21 18 18 16 14 16 FIN TYPE Hydrophilic Aluminum OUTDOOR COIL TUBE OUTSIDE DIAMETER-IN. 1/4" 3/8" 5/16" TUBE TYPE Rifled Copper Tubing NET FACE AREA-SQ.FT. 4.72 5.42 8.12 779/4.75 816/4.75 1414 DESIGN PRESSURE PSIG 550/340 SHIPPING DATA NET/SHIPPING WEIGHT 83/88 111/120 134/144 158/170 161/183 220/251 (LBS.) ELECTRICAL DATA MAXIMUM 115V 208/230V OVERCURRENT PROTECTION(AMPS) 20 20 15 15 70 25 30 50 50 ELECTRICAL CHARACTERISTICS- MINIMUM CIRCUIT 60 HZ-1 PHASE AMPACITY 15 15 15 15 15 18 20 30 35 COMPRESSOR RATED LOAD AMPS 9 10 5.3 5.7 9.5 12 14 22 23.5 OUTDOOR FAN RATED LOAD AMPS 0.6 0.6 0.42 0.42 0.5 0./ 1.0 1.0 (2)0.7 MOTOR OUTPUT-W. 40 50 120 (2)85 Page 13 SINGLE-ZONE NEAT PUMP SYSTEMS MINI-SPLITS SPECIFICATIONS-WALL MOUNTED INDOOR UNITS -1 -I a a a a a 4 4 4 44 4 al N Of N co N 0 MODEL NUMBER 0 0 0 0 a 0 0 0 0 NOMINAL SIZE-TONS 0.75 1 0.75 1 1.5 2 2.5 60 HZ-1 PHASE 115V 208/230V ELECTRICAL RATED LOAD AMPS 0.25 0.25 0.06 0.06 0.13 0.3 0.5 CHARACTERISTICS INPUT(W) 25 25 50 50 58(Output) 60(Output) 72 ROOM TEMP RANGE COOLING 62-90 (SF) HEATING 32-86 AIR VOLUME(CFM) HIGH/MED/LOW 365/265/194 370/268/196 371/274/198 530/410/295 695/624/485 794/647/500 SOUND DATA(DBA) HIGH/MED/LOW 42/33/24 41.7/33.4/26.5 45.1/-728.6 46.2/--/30.9 51.7/--/35.1 49/42/37.5 LIQUID/GAS-O.D. 1/4"/ 1/4"/ 1/4"/1/2" 1/4"/1/2" 1/4"/1/2" 3/8"/5/8" 3/8"/5/8" CONNECTIONS(IN.) -FLARE 3/8" 3/8" DRAIN-O.D. 1,. WEIGHT(LBS.) NET/PACKAGING 19.8/25.4 26.9/34.8 39.9/53.6 4012/50.26 SPECIFICATIONS -CASSETTE INDOOR UNITS 9: a a a a a 44 4 4 0j y u! 0 0 MODEL NUMBER 0 N �° N co d N M M M N N N M M M N N N o a a a a a NOMINAL SIZE-TONS 0.75 1 1.5 2 3 4 60 HZ-1 PHASE 208/230V ELECTRICAL RATED LOAD AMPS 0.9 1 1.5 2 1.5 1.6 CHARACTERISTICS INPUT(W) 45 45 45 58 141 232 ROOM TEMP COOLING 62-90 RANGE(°F) HEATING 32-86 AIR VOLUME(CFM) HIGH/MED/LOW 374/301/257 379/309/261 560/483/415 700/636/573 720/630/560 950/900/800/700 SOUND DATA HIGH/MED/LOW 41/37/33 43/39/36 44/39/36 51/47/43 55/52/49 55/52/49 (DBA) LIQUID/GAS-O.D. CONNECTIONS FLARE 1/4"/3/8 1/4"/1/2" 1/4"/1/2" 3/8"/5j8" 3/8"/5/8" 3/8"/5/8" (IN.) DRAIN-O.D. 1" 1-1/4" WEIGHT(LBS.) NET/SHIPPING 32/38 36/41 36/42 46/54 58/66 64/73 ACCESSORY INFORMATION CATALOG# 1.861 1.861 CASSETTE PANEL NET/SHIPPING 6/10 12/18 WEIGHT(LBS.) Page 14- SINGLE - .;N HEAT PUMP SYSTEMS SPECIFICATIONS - MEDIUM STATIC DUCTED INDOOR UNITS o. a a. a. a a 4r to In In In MODEL NUMBER p N co N p ES 3 63 6 z z 0 0 G E E 0 NOMINAL SIZE-TONS 0.75 1 1.5 2 2.5 3 60 HZ-1 PHASE 208/230V ELECTRICAL CHARACTERISTICS RATED LOAD AMPS 0 9 1 1.5 2 1.5 1.8 INPUT(W) 100 100 96 96 150 206 ROOM TEMP COOLING 62-90 RANGE(°F) HEATING 32-86 AIR VOLUME(CFM) HIGH/MED/LOW 335/290/240 370/320/260 520/430/360 820/620/520 1120/940/680 1470/1180/940 SOUND DATA HIGH/MED/LOW 38/35/31 44/37/31 41/39/37 53/48/43 53/51/47 52/49/46 (DBA) CONNECTIONS LIQUID/GAS-O.D.- 1/4"/3/8" 1/4"/1/2" 1/4"/1/2" 3/8"/5/8" 3/8"/5/8' 3/8"/5/8" (IN.) FLARE DRAIN-O.D. 1" WEIGHT(LBS.) NET/SHIPPING 40/51 42/52 51/61 58/69 77/92 95/114 AHRI SYSTEM MATCHES Heat Cooling HSPF HSPF Indoor Unit Type Outdoor Unit Indoor Unit SEER EER Capacity Capacity (IV) (V) 4DHP1S09S-1L DWM109S4-1L 9,500 24.5 15 11,000 11.2 9.0 4DHP1512S-11_ DWM112S4-1L 12,000 22 13 12,000 10.2 8.3 4DHP1S09S-1P DWM10954-1P 9,000 23.5 14.9 9,800 10.8 9.1 Wall-Mounted Non Ducted 4DHP1S12S-1P DWM11254-1P 12,000 22.7 13.7 12,000 11.0 9.0 4DHP1S18S-1P DWM118S4-1P 18,000 21 13 18,000 10.4 9.0 4DHP1S24S-1P DWM124S4-1P 24,000 20.7 13.7 25,000 11.5 9.8 4DHP1S30S-1P DWM130S4-1P 30,000 19.8 11.5 30,000 9.4 8.0 4DHP1S09S-1P D22C10954-1P 9,000 20 13 10,000 10.5 8.4 4DHPIS12S-1P D22C112S4-1P 12,000 21.5 14 12,000 10.5 8.4 Cassette 4DHPIS18S-1P D22C118S4-1P 18,000 20 12.5 18,000 10.3 8.8 Non-Ducted 4DHP1S24S-1P D33C124S4-1P 24,000 20 12.5 24,400 10.5 8.4 4DHP1S36S-1P D33C13654-1P 36,000 17.5 9 38,000 10.5 9.1 4DHP1S485-1P D33C148S4-1P 44,500 16.8 9.5 50,000 11 9.4 4DHP1S09S-1P DMD10954-1P 9,000 19.5 13.5 10,000 10.5 9.2 4DHP1S12S-1P DMD112S4-1P 11,000 19 12.5 12,000 10 8 Medium Static 4DHP1S18S-1P DMD118S4-1P 16,000 19 12.5 18,000 10.5 8.8 Ducted 4DHP1S24S-1P DMD124S4-1P 23,000 20 12.5 24,400 10.5 8.3 4DHP1S36S-1P DMD136S4-1P 36,000 15.5 8.5 38,000 10.5 8.7 4DHP1S48S-1P DMD14854-1P 48,000 17.4 8.9 49,500 10.3 8.8 Page 15 SINGLE-ZONE HEAT PUMP SYSTEMS MINI-SPLITS BLOWER DATA- MEDIUM STATIC DUCTED INDOOR UNITS DMD1O9S4-1P, DMD112S4-1P Low Speed Medium Speed High Speed 0.20 0.30 llI IIS 0.18 - ...... _. _...... _.. :_.. , 0.20 _..._. ..._. ___... _. .... r �i. .. I T 0.25 s G!I I E .t .._.... ... 0.16 .... _..._ _.. ...._. . ,$i 1: 3• 0.14 3 3 .} c c 0.15 c 020 .. - ..... ED 22 • 0.12 _.. ... ... _ (Cl Cl)N COd d 0.10 ._.._. ..... _...... _.... d ears 4. ... _........ 0 0.15 oM. U eal 0-r ✓ _ q c. w s. al . CO (r) N 0.10 . _ `ets:.. co Tu. 0.08 .__ _. .. N To E c E oio W 0.06 ___' .... _ __ ..._., ..._._ LI-I uJ 0.04 0 0 w 0.0s 11 fi°; u 0.02 __. _.. . -- .__. 1,4t 11; 0.00 0.00 0.00 . 160 260 360 150 200 250 300 350 400 170 220 270 320 370 420 470 Air Volume-cfm Air Volume-cfm Air Volume-cfm DMD118S4-1 P Low Speed Medium Speed High Speed 0.16 0.24 028 1 l 0.22 - 026 .. ...._.._ 0.14 __ .____ _.. ' _ 0.20 - _.... __� �� i '. 0.22 0.12 __. 7 ._.' ___. 0.18 3 _ 3 3 azo c c_0.16 __ i. _ .-.. .c ._ .. :. 0.18 _ _. : ....__... ED.' 0.10 p9 . D ,_._ z 0.14 _' - :"r'. y 0.16 I 1.2 C N .�_. 0.08 _.._._.._ i o 0.12 __ {__. `_ d 0.14 _.......... CZ OS (n _ _. fn 0.10 .. (n 0.12 t ..._ _....... • E 0.06 _...._ _. - E • c i�'_ _. .. 0.10 - s .._ . ....._. 0.08 W$ . w ...)-1( c 1. 0.08 sae�' .1/2111':. - __._ .. 0.04 ___ _... ! .__.. 0.06 ,. ... 0.06 _.._ I. _.... 0.04 :.. _.... r 0.04 0.02 _.. 0.02 .. _._.._... 0.02 r 0.00 0.00 0.00 150 250 350 450 130 230 330 430 530 150 250 350 450 550 650 Air Volume-cfm Air Volume-cfm Air Volume-cfm page 6 S' ' ._E-Z JN - -IE-t; PUNIP S' STE81S MINI-SPLITS S • DMD1024S4-1 P Low Speed Medium Speed High Speed 040 050 045 045 __.. __ .._ ,_,.� 0.40 0.40 ..._. . .... 3 - 3 0 35 - .._ } 3 0 25 _.... _i+r i - - `_ 0.-a:= c 0 30 -----. . .o 1 �i r m a30 d N 0 2s _._.__._ d °.U 0 20 __ a 0 25 __ a (71 N 020 _.. 0.15 _ c 0 20 .._ r__. N a) Y43 W D 15 ._... X W . 0.10 ..... .... ,... �. .... 010 ac.a 0.10 -__- 1* ' ._ ... __ __... ....... 005 _.. '4.1,1'4 _. 005 0.05 __.... _ _...... 0.00 0.00 0.00 260 360 460 560 660 760 860 960 250 450 650 850 1050 500 600 700 800 900 1000 1100 1200 Air Volume-cfm Air Volume-cfm Air Volume-cfm DMD136S4-1 P Low Speed Medium Speed High Speed 0.40 040 050 035 _ _... 0.45 .. _......._._. .. ... ,.. ... .. 035 ..... _.. 0 40 - ..._...._... 0.30 i y >f�r ®z 3 =..- 3 035 + 1 q ..4° .0 '4144 02 N 0 O25 .......... _... ' < N 7 0.30 1n N e) N y ma` U 020 d 020 _. d o25 COCO ICJ 0- ria ` 0.15 .. ` 0.15 C _ a1 E l' W w X W 0.15 ...... :.... 010 0.10 0.10 ,, 0.05 1t+ ss to ` 0.05 __ }L e „der,, _ + 005 0.00 0 G 0.00 400 500 600 700 800 900 1000 1100 1200 600 700 800 900 1000 1100 1200 1300 400 600 800 1000 1200 Air Volume-cfm Air Volume-cfm Air Volume-cfm Page 17 SINGLE-ZONE NEAT PUMP SYSTEMS MINI s I_IT BLOWER DATA- MEDIUM STATIC DUCTED INDOOR UNITS DMD148S4-1 P, Low Speed Medium Speed High Speed 0.40 0.45 __ ._... ._. __.. 0.50 0.40 .... ._.. _....... __.. _.._ 0.45 .. ..... ._.... .._.. ......... 0.35 _ _..... _._. _ __ . 0.40 0.35 .._. . ...... ..._ _.... ... . 0.30 _. _._ .._. _.. _...._ co ti) as 3 3 3 0.3s C c 0.30 .... .... ___. pa,; _.._. C 3 a,, ._ ... — .- 0.25 $+..�: .._.._ "L.0.. .. _. °i° 0.30 .,.... N 0.25 ..._ ..._ ....... U) 22 L d 0.20 ._ .... ... ...... 0_ d 0.25 ... U U — .� 0.20 ..... _..... ... .. .._. (13 cn co vs — 0.20 To N @ 0.15 ..__ __.... ._.. _.. _.... E _ E !. X X 0.15 LisUl W 0.15 - - 0.10 _.. _._ . _. . .... 0.10 _...-. .... _ ...._ ....__ ,z 0.10 _.${ _ __ , a II _.... _._ _._ _... 0.05 .,4 f;` _..... __....._ ..._. ....._ 0.05 ,. _ -_. _ _..... I 0.00 0.00 __._....._._. _ _.....__ ._.. __...�_ ...— ._......._._ . 0.00 700 900 1100 1300 1500 1700 700 900 1100 1300 1500 700 900 1100 1300 1500 1700 Air Volume-cfm Air Volume-cfm Air Volume-cfm nage 'g - SINGLE-ZONE HEAT PUMPSYSTEMS MINI-SPITS LINE SET AND ELEVATION GUIDELINES Outdoor Unit BELOW Indoor Unit Outdoor Unit ABOVE Indoor Unit INDOOR UNIT OUTDOOR UNIT Maximum Line Set Maximum Line Set I gth Lengthi Maximum Maximum Elevation - INDOOR UNIT Elevation- Outdoor Unit Outdoor Unit Below Above Indoor UnitOUTDOOR UNIT J Indoor Unit .i LINE SET DIAMETERS(IN.) MAXIMUM MAXIMUM MAXIMUM ELEVATION- ELEVATION- SIZE OUTDOOR UNIT OUTDOOR UNIT LINE SET LIQUID GAS BELOW INDOOR UNIT ABOVE INDOOR UNIT LENGTH FT.(M) FT.(M) FT.(M) 009 1/4 3/8 40 ft.(12 m) 40 ft.(12 m) 82 ft.(25 m) 012 1/4 1/2 40 ft.(12 m) 40 ft.(12 m) 82 ft.(25 m) 018 1/4 1/2 66 ft.(20 m) 66 ft.(20 m) 98 ft.(30 m) 024,030 3/8 5/8 82 ft.(25 m) 82 ft.(25 m) 164 ft.(50 m) 036,048 3/8 5/8 98 ft.(30 m) 98 ft.(30 m) 213 ft.(65 m) Page 19 JGLE-ZONE HEAT PUMP y TE 1 NESPLIT ACCESSORIES(FURNISHED) WIRELESS REMOTE CONTROL TURBO BUTTON • Furnished with Wall-Mounted Indoor Units,Cassette Indoor • Enables the unit to reach the preset temperature during cooling Units and Ceiling/Floor Indoor Units. or heating operation in the shortest time. • NOTE-Can be ordered separately for ducted indoor units. • Complete remote control of system.Maximum operating range SELF CLEAN BUTTON is 25 ft. • Automatically cleans and dries the evaporator coil at the end of • Operates on two AAA 1.5V batteries(furnished). the cooling season,preventing any odors or mildew. • Wireless remote control holder furnished.Holder can be mounted on a wall for easy access.Mounting screws furnished. UP/DOWN BUTTONS • Increase or decrease the indoor temperature in one degree increments(maximum 86°F,minimum 62°F). • NOTE-Temperature cannot be adjusted in FAN mode. • NOTE-Press and hold and buttons together for 3 seconds to alternate the temperature display between the°C and°F scale. O e SILENCE/FP BUTTON O I . O NIOFF I IT© ® • Silence-Operates the compressor at low frequency and low fan TIME' TEMP ° speed to reduce operating sound levels to a minimum. 0 ICI E.F'I • FP-Only available during heating operation.Unit will operate at Q I'g °IME°7I © a set temperature of 46°F. © • NOTE-To cancel,push the"ON/OFF","SLEEP","FP","MODE", 0 �` �I © "FAN SPEED","UP/DOWN"buttons. • TIMER ON/TIMER OFF Buttons • TIMER ON(initiates an auto-on time sequence)and TIMER OFF (initiates an auto-off time sequence)can be used separately or together. ON/OFF BUTTON Each press of the button increases the time in 30 minute increments up to 10 hours.Above 10 hours each press of the • Turns system on and off. button will increase the auto-timed setting by 60 minutes up to 24 hours. MODE BUTTON • NOTE-To cancel,set timer to 0.0 or turn remote off and on. • Select system operation modes.Push button to cycle through - each setting. SWING Button r AUTO—►COOL—►DRY—' HEAT --►FAN '1 • Used to stop or start horizontal louver auto swing feature. • DIRECT Button • Used to change the louver movement and set the desired up/ FAN BUTTON down air flow direction. • Select fanspeed.Push button to ryciP throw eac setting. • The louver angle changes 6°for each press of the button. rAUTO-► LOW---.MED--+ HIGH 1 • FOLLOW ME Button • NOTE-Not available in AUTO or DRY modes. • Allows remote temperature sensing of the room at the remote • SLEEP Button control location. • Enables the system to automatically increase cooling or • LED Button decrease heating(in 2°F increments)per hour for the first 2 • Turns the LCD display backlight on the indoor unit on or off. hours,then maintain a steady temperature for 5 hours. • NOTE-To cancel,push the"MODE","FAN SPEED"or"ON/ OFF"buttons. • NOTE-SLEEP mode is only available when the unit is in COOL, HEAT or AUTO mode. Page 20 • G(..c_ON- HE../,'T ACCESSORIES (FURNISHED) WIRELESS REMOTE CONTROL OPERATION • Auto Operation • Press the MODE button to select Auto. • Press the UP/DOWN button to set the desired temperature.The Vp O O ON 0 OFF temperature can be set within a range of AUTOS SET TEMP. • Press the ON/OFF button to start the air conditioner. COOL • °F +` • Cooling/Heating/Fan Operation DRY "�'' © • Press the MODE button to select COOL,HEAT or FAN mode. " • Press the UP/DOWN buttons to set the desired temperature. ' '� HEAT • Press the FAN button to select the fan speed in four steps FAN = FAN =MD AUTO, Auto,Low, Med,or High. • Press the ON/OFF button to start the air conditioner. Mode display • Dehumidifying Operation AUTO CD COOL * DRY • Press the MODE button to select DRY mode. HEAT FAN • Press the UP/DOWN buttons to set the desired temperature. • Press the ON/OFF button to start the air conditioner. Displayed when data transmitted. • Timer ON/OFF Operation • Press the TIMER ON or TIMER OFF button.The remote 0 Displayed when remote controller is ON. controller shows TIMER ON or TIMER OFF icon,the previous mi Battery display(low battery detection) Auto-on time setting and the signal"H"will be shown on the LCD display area. 0 ON Displayed when TIMER ON time is set. • Push the TIMER ON or TIMER OFF button again to set desired C OFF Displayed when TIMER OFF time is set. time. Each time you press the button,the time increases by 30 (�„ Show set temperature or room minutes between 0 and 10 hours and by 60 minutes between 1� temperature,or time under TIMER 10 and 24 hours. setting. • After setting the TIMER ON or TIMER OFF there will be a one second delay before the remote control transmits the signal Displayed in Sleep Mode operation. to the unit.After approximately 2 seconds,the signal"H"will 0 Indicated that the air conditioner is disappear and the set temperature will re-appear on the LCD operating in Follow me mode display window. Fan speed indication FAN ))) Low speed FAN )))))) Medium speed FAN )))))))))) High speed FAN AUTO Auto fan speed Note-During unit operation only the active functions will be shown on the display. Page 21 SINGLE-ZONE HEAT PUMP SYSTEMS MINI-S I__'TS ACCESSORIES(FURNISHED) WIRED REMOTE CONTROL FAN SPEED Button • Furnished with Ducted Indoor Units. • Selects fan speed.Each button press cycles through the • NOTE-Can be ordered separately for non-ducted indoor units. following settings on display. FEATURES p C' • Backlight-Allows easy operation in a dark room.The controller r a lights when any button is pressed and remains lit during control L - access. • NOTE-Not available in AUTO mode. • Permanent Memory-Maintains clock,fan speed and mode of • TIMER ON/TIMER OFF Buttons operation settings following power outages. • TIMER ON(initiates an auto-on time sequence)and TIMER OFF • Dimensions(H x W x D)-4-3/4 x 4-3/4 x 7/8 in. (initiates an auto-off time sequence)can be used separately or • Additional hardware is furnished for installation. together. • Wiring-Controller uses 5-wire shielded cable(not furnished) Each press of the button increases the time in 30 minute for easy low voltage connection to the indoor unit. increments up to 10 hours.Above 10 hours each press of the DISPLAY button will increase the auto-timed setting by 60 minutes up to MODE DISPLAY 24 hours. FOLLOW ME INDICATOR • NOTE-To cancel,set timer to 0.0. ON/OFF INDICATOR UP/DOWN BUTTONS Agin C7. QA(�orol ur, IST Ha IpNOY \;i' • Increase or decrease the indoor temperature in two degree increments(maximum 88°F,minimum 62°F). 81E111EINE SW 10 & RIMED ADD FAN SPEED INDICATOR • NOTE-Temperature cannot be adjusted in FAN mode. MINIM ®G 'iI 1Wh ao, 6d� add? • NOTE-Press and hold and buttons together for 3 seconds to a „ alternate the temperature display between the°C and°F scale. LOCK INDICATOR SWING BUTTON TIME(ON/OFF) TBYIPEERAnlEDISPI"'" • Used to stop or start horizontal louver auto swing feature. BUTTONS AND FUNCTIONS • ECONOMY Button \ • Maintains the most comfortable temperature and saves energy. • RESET Button(Recessed) Cn POWER • Resets Controller to factory settings.Recessed to prevent tampering. • LOCK Button(Recessed) MODE SELECTION • Locks Controller buttons to prevent tampering with settings. TIMER ON a r r ADJUSTMENT UP TIMER OFF— M r ADJUSTMENT DOWN FOLLOW ME O _ `® . O O SWING ECONOMY RESET FAN SPEED SELECTION unac MODE Button Select system operation modes.Push button to cycle through eachsetting. I AUTO--1.-COOL-0-DRY--0-;HEAT —►FAN 1 POWER Button I Turns system on and off. Page 22 SINGLE-ZONF HEAT 'UN1P EAE i EMSMINI-SPLITS I�� �� .ISS OPTIONAL ACCESSORIES - ORDER SEPERATLEY DESCRIPTION CATALOG# 09 12 18 24 30 36 48 OUTDOOR UNIT CONDENSER PAD(18 X 36 X 2) 48X92 x x x x x x x 30 AMP,FUSED, 27P37 x x x x x x x 1 PH DISCONNECTS 60 AMP,NON- 27P39 x x x x x x x FUSED,1PH 30A 83P75 x x x x x x x FUSES 60A 83P77 x x x x x x x 1/4"X 3/8"X 25' 90X53 x 1/4"X 3/8"X 50' X0258 x 1/4"X 1/2"X 25' 90X52 x x LINE SETS 1/4"X 1/2"X 50' X0259 x x 3/8"X 5/8"X 25' X8406 x x x x 3/8"X 5/8"X 50' X8407 x x x x 30" Y5020 x x x x WALL BRACKETS 36" Y5021 x x x 10 GAUGE-1/2" 29P54 x x x x x x x X 6' WHIPS 8 GAUGE-3/4" 27P44 x x x x x x x X 6' INDOOR UNIT 7.9 US GALLONS/ CONDENSATE PUMP HR.35 FT.LIFT- Y5170 x x x x x x x 120/240V CONTROLS WIRELESS REMOTE CONTROL 1.861056 x x x x x x x WIRED REMOTE CONTROL 1.861057 x x x x x x x 14 GAUGE,4 INDOOR/OUTDOOR CONDUCTOR Y2067 x x x x x x x WIRING CABLE WIRE,THHN,250 FT. NOTE-CONTROLS ARE FURNISHED WITH INDOOR UNITS.WIRED WITH DUCTED,WIRELESS WITH ALL OTHERS.THESE ACCESSORIES ARE ALTERNATIVES FOR THOSE OPTIONS-I.E.WIRELESS WITH DUCTED OR WIRED WITH ALL OTHERS. LINESET COVER STARTER KIT 4" Y3387 x x x x x x x LINESET COVER 4"X 6.5' Y3388 x x x x x x x UNION COUPLING 4" Y3389x x x x x x x 90 DEGREE FLAT 4" Y3390x x x x x x BEND ELBOW 90 DEGREE INSIDE 4" Y3391x x x x x x x ELBOW 45 DEGREE FLAT 4" Y3392x x x x x x x BEND ELBOW FLEX JOINT 4" Y3393 x x x x x x x T-JOINT 4" Y3394 x x x x x x x DUCT END 4" Y3395 x x x x x x x FALT WALL 4" Y3396 x x x x x x x ESCUTCHEON WALL PENETRATION 4" Y3399 x x x x x x x COVER MOUNT BLOCK QTY(2)-14" Y3397 x x x x x x x (WHITE) MOUNT BLOCK QTY(2)-36" Y3398 x x x x x x x (WHITE) Page 23 S1NGLE-ZONE HEAT PUMP SYSTEMS MSN!-SP !TS _ _ 4LLIEDTM Air Enterprises 1-800-448-5872 All specifications and illustrations subject to change without notice and without incurring obligations. FORM NO.4DHPSINGLE-100(11/2016) ©2016 Allied Air Enterprises I_L.C.a Lennox International Inc.Company Printed in the U.S.A. Page 24