Specifications (5) S-1
SUSPENDED CEILING CALCULATIONS
LEWIS &
Lconsulting engineers
18660 s.w. boones ferry road
tualatin,oregon 97062
503.885.8605 phone 503.885,1206 fax
VAN VLEET
incorporated
PROJECT: ITem leton Elementary ry_Condition 1, Level 2, Type 1
TYPE OF GRID: ACOUSTICAL CEILING
CERTAINTEED 15/16"TEE SYSTEM
CS12-12-20
CS4-12-20
CS2-12-20
WA15-15
CTSPC-2 PERIMETER CLIP
DISTANCE FROM CEILING ACOUSTICAL GRID-MAX. DROP = 6 FEET
TO STRUCTURE:
COMPRESSION STRUTS: SEE PAGE 5-` FOR SUMMARY
DIAGONAL WIRE SPLAYS: 12 GA. 55 KSI 4 WAYS AT EACH COMPRESSION STRUT
VERTICAL HANGER WIRES: 12 GA. 55 KSI AT 4'-0"O.C. ALONG MAIN RUNNERS
STRUCTURE ABOVE CEILING: OPEN WEB JOIST
FASTENERS FOR SPLAY WIRES: 1/4" DIA. X 3" LAG SCREW W/EYE TO JOIST CHORD
PERIMETER WIRES IN EACH ORTHOGONAL DIRECTION, ONE END OF THE
AND ATTACHMENTS: CEILING GRID MAY BE ATTACHED TO THE CLOSURE ANGLE.
THE OTHER ENDS IN EACH HORIZONTAL DIRECTION SHALL
HAVE 3/4 INCH CLEARANCE FROM THE WALL AND BE
SUPPORTED BY AN ARMSTRONG BERC-2 SEISMIC
PERIMETER CLIP AT ALL MAIN AND CROSS RUNNERS. NO
PERIMETER WIRES ARE REQUIRED IN THIS INSTANCE. THIS
FRAMING OPTION MUST BE APPROVED BY THE LOCAL
AUTHORITY HAVING JURISDICTION.
STRUT AND SPLAY SPACING: 12'-0"X 12'-0" OR MAXIMUM 144 SQUARE FEET
SUSPENDED CEILING CALCULATIONS 7--
LEWIS &
L
consulting engineers
18660 s.w. boones ferry road
tualatin,Oregon 97062
503.885.8605 phone 503.885.1206 fax
VAN VLEET
•
incorporated
CEILING MOUNTED LIGHT LIGHTING FIXTURES, EGRESS LIGHTING, SPEAKER,AIR
FIXTURES, EGRESS LIGHTS, TERMINALS, OR MECHANICAL SERVICES WEIGHING UP
SPEAKER,AIR TERMINALS, TO 56 POUNDS AND DIRECTLY SUPPORTED BY THE
MECHANICAL SERVICES, CEILING GRID SYSTEM SHALL BE POSITIVELY
AND OTHER CEILING ATTACHED TO THE CEILING SYSTEM. ATTACHMENT
SUPPORTED EQUIPMENT: SHALL BE MADE WITH A MINIMUM OF 4 APPROVED
FASTENERS LOCATED WITHIN 3 INCHES OF THE GRID
INTERSECTIONS TO SUSPENSION MAIN RUNNERS, OR
TO CROSS RUNNERS WITH THE SAME CARRYING
CAPACITY OF THE MAIN RUNNERS. IN ADDITION TO
THE ABOVE GRID CONNECTION, FIXTURES WEIGHING
AT LEAST 20 POUNDS BUT NOT MORE THAN 56
POUNDS SHALL HAVE TWO 0.080 INCH (12 GAUGE
A.W.G.) HANGER WIRES CONNECTED FROM THE
FIXTURE TO THE CEILING SYSTEM HANGERS OR TO
THE STRUCTURE ABOVE. THESE WIRES MAY BE
SLACK. FIXTURES WEIGHING LESS THAN 20 POUNDS
DO NOT REQUIRE SLACK WIRES. FIXTURES WEIGHING
MORE THAN 56 POUNDS SHALL BE SUPPORTED
INDEPENDENTLY FROM THE STRUCTURE ABOVE
INDEPENDENTLY OF THE GRID SYSTEM WITH
APPROVED HANGERS. CABLE TRAYS, ELECTRICAL
CONDUIT, COMMUNICATION CABLE, AND OTHER
SIMILAR INSTALLATIONS SHALL BE SUPPORTED
INDEPENDENTLY FROM THE CEILING.
DESIGN SCOPE: STRUTS AND SPLAYS ARE NOT REQUIRED FOR CEILINGS IN
ROOMS LESS THAN 1000 SQUARE FEET IN AREA(IN AREAS
WITH THE SURROUNDING WALLS BRACED TO STRUCTURE).
ENGINEERING: LEWIS&VAN VLEET INC. HAS BEEN RETAINED TO DESIGN
THE CEILING GRID SUPPORT AND BRACING, AND•
ATTACHMENTS FROM THE GRID SYSTEM TO THE
SUPPORTING STRUCTURE. IT IS THE RESPONSIBILITY OF
THE BUIDING OWNER, CONTRACTOR, OR ENGINEER OF
RECORD TO VERIFY THAT THE STRUCTURE HAS ADEQUATE
STRENGTH AND LATERAL STABILITY TO RESIST THE LOADS
IMPOSED ON IT BY THE SUSPENDED CEILING.
CODES: LEWIS &VAN VLEET, INC. HAS FOLLOWED THE STANDARD
PROVISIONS OF THE 2012 IBC, THE 2014 OSSC, AND ASCE 7-
10 IN THE DESIGN OF THIS SYSTEM.
SUSPENDED CEILING CALCULATIONS S
LEWIS &
L
consulting engineers
18660 sw.boones ferry road
tualatin,Oregon 97062
503.885.8605 phone 503.885.1206 fax
VAN VLEET
incorporated
LATERAL LOADING:CONDITION NO. 1, LEVEL 2, TYPE 1
SPECTRAL ACCELERATION Sos= 0.715
SITE CLASS= D
IMPORTANCE FACTOR Ip= 1.25
COMPONENT AMPLIFICATION FACTOR ap= 1
COMPONENT AMPLIFICATION FACTOR Rp= 2.5 I
I
CEILING WEIGHT w= 4 PSF
ATTACHMENT HEIGHT OF CEILING z= 32 FEET 1+2 *z/h = 3.000
AVERAGE ROOF HEIGHT h= 32 FEET
DESIGN FOR TOTAL LATERAL FORCE FOR A 12'X 12' GRID:
TOTAL WEIGHT: Wp = w* 12' * 12' = 576 LBS.
LATERAL LOAD: Fp = 0.4*a *S *W *0.7 2 *z
1 +
Rp/Ip h ._
Fp= 173 LBS. ASCE 7-10 ++ (EQ. 13.3-1)
MANDATORY LOWER BOUND: Fp= 108 LBS. ASCE 7-10++ (EQ. 13.3-3)
OPTIONAL UPPER BOUND: Fp = 577 LBS. ASCE 7-10++ (EQ. 13.3-2)
++ NOTE: 0.7 FACTOR IS APPLIED TO THE FORCES FOR ALLOWABLE STRESS DESIGN
S
SUSPENDED CEILING CALCULATIONS
LEWIS &
Lconsulting engineers
18660 sm.boones ferry road
c.*"' tualatin,oregon 97062
'.- 503.885.8605 phone 503.885.1206 fax
SPLAY WIRE AND CONNECTION TO STRUCTURE: CONDITION NO. 1, LEVEL 2,TYPE 1
Strut Wire CEILING GRID 12 FT.X 12 FT.
45 deg.
Ceiling
CHECK DIAGONAL WIRE SPLAYS: 12 GA, Fy= 55,000 PSI A= 0.0088 SQ. IN.
CAPACITY OF WIRE: Tmax=0.6*Fy 8*A
= 290 LB.
CONTROLLING SEISMIC FORCE: Fp DESIGN= 173 LB.
TENSION IN WIRE: T =Fp DESIGN/COS 45 DEG. = 245 LB. OK
1/4"DIA.X 3"LAG SCREW W/EYE TO JOIST CHORD
CHECK COMPRESSION STRUT:
1'-0"to 6'-O"use 1 5/8"-20 GA. STUD WITH 1 1/4"FLANGES
SSMA SECTION 162S125-33
SUSPENDED CEILING CALCULATIONS S-S
LEWIS &
consulting engineers
18660.s.w. boons ferry road
L
tualatinOregon 97062
503.885.8605 phone 503.885.1206 fax
VAN VLEET
incorporated
PERIMETER CLOSURE ANGLE SUPPORT AT WALL:
CHECK WALL ANGLE SUPPORT AT WALL --MINIMUM 7/8"X 718"X 0.0188"ANGLE
, IlilLpiill ..aa.... ....\11=;11i ...we...) ....)
Zif
CHECK.THIS SPAN MINIMUM#S SCREW
aft.
I i I
/L
2
ft. SUSPENSION WIRE
CONNECTION POINT
Oft. 4 ft.
FRAMING PLAN
p DL = 4 PSF
P =4 PSF x 4 FT x 1/2 x8FTx1/2x1/2
W = 16 LB
11111111111111111111111111111
w =4 PSF x 2 FT x 1/2
= 4 PLF
R R
RMAx = 16 LB +4 PLF x 4 FT x 1/2 (CONTINUOUS ANGLE)
= 24 LB
M = 16 LB x 2 FT x 1/8 +4 PLF x(2 FT)2 x 1/12 (CONTINUOUS ANGLE)
= 5.33 FT-LB
OK-SEE ANGLE CAPACITY CALCULATION ON NEXT PAGE
SUSPENDED CEILING CALCULATIONS U-(n
LEWIS &
L
consulting engineers
18660 s.w.boones ferry road
tuafatin,oregon 97062
503.885.8605 phone 503.885.1206 fax
VAN VLEET
incorporated
ANGLE CAPACITY CALCULATION
0.875°MIN.
/
/
0.875"MIN.
DISREGARD
STIFFENING LIPS
1
(0.875 IN)r (0.0188 IN)` ~
0.0188 IN + (0.875 IN-0.0188 IN)
2 _ _ 2 _
y=
0.0188 IN x(2 x 0.875 IN-0.0188 IN)
y= 0.2258 IN
(0.875IN)' - 0.875 IN —2
IYVLEG =0.0188 IN x + 0.0188 IN x 0.875 IN x -0.226 IN
12 .� 2
= 0.0018 IN4 -'
(0.0188 IN)3 0.0188 IN— 2
IYHLEG =(0.875 IN -0.0188 IN) +(0.875 IN-0.0188 IN)x0.0188 IN x 0.226 IN-
12 2
- 0.00076 IN4
IY- IYVLEG + IYHLEG = 0. 0.00254 IN4
ly
Sy= = 0.0039 IN3
0.875 IN -0.226 IN
MCAP =Syx0.6x33KSI =6.46 FT-LB > 5.33 FT-LB ACTUAL-OK
ANGLE SPANS 24" BETWEEN STUDS
SUSPENDED CEILING CALCULATIONS S-`i
LEWIS &
consulting engineers
18660 s.w.boones ferry road
L
tualatin,Oregon 97062
503 885 8605 phone 503.885.1206 fax
VAN VLEET /�
incorporated 1/ 1 ..:1
ANGLE FASTENING TO STUDS
24 LB MAXIMUM
.• lir
i
1
"V ..
24" 1,11,e. 111
t, jor Fp
R 4d/re". fig SCREWS
6."
TO STUDS
R1-= Rv= 24 LB MAXIMUM
TcAPACInY=226 LB/3.0= 75.3 LB
VcAPACITY=520 LB/3.0= 173 LB
24 24
INTERACTION: + = 0.457 <1 OK
75.3 173
#8 SCREW TO EACH STUD OK
Project Name: Light gauge Page 1 of 1
Model: Condition 1 Date:12/12/2018
Code: 2012 NASPEC(AISI S100-20121 Simpson Strong-Tie®CFS Designer"' 1.5.0.0
Reactions and Connections
! Number of Connectors Required at each Reaction: 1
No.of No.of
Simpson Req'd Req'd#
Strong-Tie screws to 12-14
Support Reaction(Ib) Connector stud Anchors
RI 0.00 No Solutions - -
R2 0.00 No Solutions - -
Total Vertical Shear Carried by Connectors(Ib): 0
Bridging Connectors-Design Method=AISI S100
Simpson Strong-Tie
SpanlCantiLever Bridging Connector Stress Ratio
6.00 Span N/A -
Shear and Web Crippling Checks
Bending and Shear(Unstiffened): N/A
Bending and Shear(Stiffened): NA
Web Stiffeners Required?: No
I
Section : 162S125-33 Single C Stud Fy=33.0 ksi
Maxo= 114.0 Ft-Lb Moment of Intertia,I=0.07 in^4 Va=600.7 lb
Loads have not been modified for strength checks
Loads have been multiplied by 0.70 for deflection calculations
Reactions have been multiplied by 1.0 for opposite load direction for connection design
Flexural and Deflection Check Deflection
Mmax Mmax/ Mpos Bracing Ma(Brc) Mpos/
Span Ft-Lb Maxo Ft-Lb (in) Ft-Lb Ma(Brc) (in) Ratio
Span 0.0 0.000 0.0 None 73.9 0.000 0.000 110
Distortional Buckling Check
Span K-phi . Lm Brac Ma-d Mmax/
lb-in/in in Ft-Lb Ma-d
Span 0.00 72.0 123.4 0.000
Combined Bending and Axial Load Details
Axial Ld Bracing(in) Max K-Phi Lm Bracing Allow Intr.
Span (Ib) KyLy KtLt KUr (lb-in/in) (in) load(Ib) P/Pa Value
Span 173.0(c) None None 164 0.0 72.0 316.1(c) 0.55 0.55
SIMPSON STRONG-TIE COMPANY INC. www.strongtie.com
SUSPENDED CEILING CALCULATIONS
LEWIS &
Lconsutrng engineers
18660 sw.boones ferry road
ualatin,oregon 97062
503.885.8605 phone 503.885.1206 fax
VAN VLEET
incorporated
PROJECT: Templeton Elementary-Condition 2, Level 1, Type 1
TYPE OF GRID: ACOUSTICAL CEILING
CERTAINTEED 15/16"TEE SYSTEM
CS12-12-20
CS4-12-20
CS2-12-20
WA15-15
CTSPC-2 PERIMETER CLIP
DISTANCE FROM CEILING ACOUSTICAL GRID -MAX. DROP= 4.6667 FEET
TO STRUCTURE:
COMPRESSION STRUTS: SEE PAGE S-\L FOR SUMMARY
DIAGONAL WIRE SPLAYS: 12 GA. 55 KSI 4 WAYS AT EACH COMPRESSION STRUT
VERTICAL HANGER WIRES: 12 GA. 55 KSI AT 4'-0" O.C. ALONG MAIN RUNNERS
STRUCTURE ABOVE CEILING: OPEN WEB JOIST
FASTENERS FOR SPLAY WIRES: 114" DIA. X 3" LAG SCREW W/EYE TO JOIST CHORD
PERIMETER WIRES IN EACH ORTHOGONAL DIRECTION, ONE END OF THE
AND ATTACHMENTS: CEILING GRID MAY BE ATTACHED TO THE CLOSURE ANGLE.
THE OTHER ENDS IN EACH HORIZONTAL DIRECTION SHALL
HAVE 3/4 INCH CLEARANCE FROM THE WALL AND BE
SUPPORTED BY AN ARMSTRONG BERC-2 SEISMIC
PERIMETER CLIP AT ALL MAIN AND CROSS RUNNERS. NO
PERIMETER WIRES ARE REQUIRED IN THIS INSTANCE. THIS
FRAMING OPTION MUST BE APPROVED BY THE LOCAL
AUTHORITY HAVING JURISDICTION.
STRUT AND SPLAY SPACING: 12'-0"X 12'-0" OR MAXIMUM 144 SQUARE FEET
S-10
SUSPENDED CEILING CALCULATIONS
LEWIS &
L consulting
engineers
8660 s.w.boones ferry road
ualatin,oregon 97062
03.885.8605 phone 503.885.1206 fax
VAN VLEET
incorporated
CEILING MOUNTED LIGHT
FIXTURES, EGRESS LIGHTS, LIGHTING FIXTURES, EGRESS LIGHTING, SPEAKER,AIR
SPEAKER,AIR TERMINALS, TERMINALS, OR MECHANICAL SERVICES WEIGHING UP
MECHANICAL SERVICES, TO 56 POUNDS AND DIRECTLY SUPPORTED BY THE
AND OTHER CEILING CEILING GRID SYSTEM SHALL BE POSITIVELY
SUPPORTED EQUIPMENT: ATTACHED TO THE CEILING SYSTEM. ATTACHMENT
SHALL BE MADE WITH A MINIMUM OF 4 APPROVED
FASTENERS LOCATED WITHIN 3 INCHES OF THE GRID
INTERSECTIONS TO SUSPENSION MAIN RUNNERS, OR
TO CROSS RUNNERS WITH THE SAME CARRYING
CAPACITY OF THE MAIN RUNNERS. IN ADDITION TO
THE ABOVE GRID CONNECTION, FIXTURES WEIGHING
AT LEAST 20 POUNDS BUT NOT MORE THAN 56
POUNDS SHALL HAVE TWO 0.080 INCH (12 GAUGE
A.W.G.)HANGER WIRES CONNECTED FROM THE
FIXTURE TO THE CEILING SYSTEM HANGERS OR TO
THE STRUCTURE ABOVE. THESE WIRES MAY BE
SLACK. FIXTURES WEIGHING LESS THAN 20 POUNDS
DO NOT REQUIRE SLACK WIRES. FIXTURES WEIGHING
MORE THAN 56 POUNDS SHALL BE SUPPORTED
INDEPENDENTLY FROM THE STRUCTURE ABOVE
INDEPENDENTLY OF THE GRID SYSTEM WITH
APPROVED HANGERS. CABLE TRAYS, ELECTRICAL
CONDUIT, COMMUNICATION CABLE, AND OTHER
SIMILAR INSTALLATIONS SHALL BE SUPPORTED
INDEPENDENTLY FROM THE CEILING.
DESIGN SCOPE: STRUTS AND SPLAYS ARE NOT REQUIRED FOR CEILINGS IN
ROOMS LESS THAN 1000 SQUARE FEET IN AREA(IN AREAS
WITH THE SURROUNDING WALLS BRACED TO STRUCTURE).
ENGINEERING:
LEWIS &VAN VLEET INC. HAS BEEN RETAINED TO DESIGN
THE CEILING GRID SUPPORT AND BRACING, AND
ATTACHMENTS FROM THE GRID SYSTEM TO THE
SUPPORTING STRUCTURE. IT IS THE RESPONSIBILITY OF
THE BUIDING OWNER, CONTRACTOR, OR ENGINEER OF
RECORD TO VERIFY THAT THE STRUCTURE HAS ADEQUATE
STRENGTH AND LATERAL STABILITY TO RESIST THE LOADS
IMPOSED ON IT BY THE SUSPENDED CEILING.
CODES: LEWIS&VAN VLEET, INC. HAS FOLLOWED THE STANDARD
PROVISIONS OF THE 2012 IBC, THE 2014 OSSC, AND ASCE 7-
10 IN THE DESIGN OF THIS SYSTEM.
S-t\
SUSPENDED CEILING CALCULATIONS
LEWIS &
L
consulting engineers
18660 sw.boones ferry road
tualatin,oregon 97062
503.885.8605 phone 503.885.1206 fax
VAN VLEET
incorporated
LATERAL LOADING: CONDITION NO. 2, LEVEL 1, TYPE 1
SPECTRAL ACCELERATION Sps= 0.715
SITE CLASS= D 1
IMPORTANCE FACTOR IP= 1.25
COMPONENT AMPLIFICATION FACTOR ap = 1
COMPONENT AMPLIFICATION FACTOR Rp= 2.5
CEILING WEIGHT w= 4 PSF
ATTACHMENT HEIGHT OF CEILING z= 16 FEET 1+2 *z/h = 2.000
AVERAGE ROOF HEIGHT h = 32 FEET
DESIGN FOR TOTAL LATERAL FORCE FOR A 12'X 12'GRID:
TOTAL WEIGHT: Wp = w* 12' * 12' = 576 LBS.
LATERAL LOAD: Fp = 0.4*ap*S *W *0.7 2 *z
1 +
Rp/Ip h
Fp= 115 LBS. ASCE 7-10 ++ (EQ. 13.3-1)
MANDATORY LOWER BOUND: Fp= 108 LBS. ASCE 7-10 ++ (EQ. 13.3-3)
OPTIONAL UPPER BOUND: Fp = 577 LBS. ASCE 7-10++ (EQ. 13.3-2)
++ NOTE: 0.7 FACTOR IS APPLIED TO THE FORCES FOR ALLOWABLE STRESS DESIGN
S-Al-
.
SUSPENDED CEILING CALCULATIONS
LEWIS &
1L
- consulting engineers
18660 s.w.boones ferry road
`- tualatin,Oregon 97062
503.885.8605 phone 503.885.1206 fax
SPLAY WIRE AND CONNECTION TO STRUCTURE: CONDITION NO.2, LEVEL 1, TYPE 1
Strut Wire CEILING GRID 12 FT. X 12 FT.
45 deg.
Ceiling
CHECK DIAGONAL WIRE SPLAYS: 12 GA. Fy= 55,000 PSI A= 0.0088 SQ. IN.
CAPACITY OF WIRE: Tmax= 0.6* Fy 8*A
= 290 LB.
CONTROLLING SEISMIC FORCE: Fp DESIGN= 115 LB.
TENSION IN WIRE: T= Fp DESIGN I COS 45 DEG. = 163 LB. OK
1/4"DIA. X 3" LAG SCREW W/EYE TO JOIST CHORD
CHECK COMPRESSION STRUT:
1'-0"to 6'-O" use 1 5/8"-20 GA. STUD WITH 1 1/4" FLANGES
SSMA SECTION 162S125-33
SUSPENDED CEILING CALCULATIONS
LEWIS &
Lconsulting engineers
18660
tualatins.w.boonesOregon97062 ferry road
,503.885.8605 phone 503.885.1206 fax
VAN VLEET
incorporated
PERIMETER CLOSURE ANGLE SUPPORT AT WALL:
CHECK WALL ANGLE SUPPORT AT WALL--MINIMUM 7/8"X 7/8"X 0.0188"ANGLE
i' -�. _I -
J _.J.
1 \CHECK THIS SPAN MINIMUM#8 SCREW
2ft.
I I f
2 ft. SUSPENSION WIRE
CONNECTION POINT
Oft. Oft.
FRAMING PLAN
P DL= 4 PSF
P =4 PSF x 4 FT x 1/2 x 8 FT x 1/2 x 1/2
W = 16 LB
1111111111111111 1111111
w =4 PSF x 2 FT x 1/2
= 4 PLF
R R
RMAx = 16 LB+4 PLF x 4 FT x 1/2 (CONTINUOUS ANGLE)
24 LB
M = 16 LB x 2 FT x 1/8 +4 PLF x(2 FT)2 x 1/12 (CONTINUOUS ANGLE)
5.33 FT-LB
OK-SEE ANGLE CAPACITY CALCULATION ON NEXT PAGE
SUSPENDED CEILING CALCULATIONS S ;'l
LEWIS &
Lconsuitina engineers
18660 s.w.boones ferry road
tttalatin,oregon 97062
503.885.8605 phone 503.885.1206 fax
VAN VLEET
incorporated
ANGLE CAPACITY CALCULATION
0275"MIN.
/ f'
f
0.0188"
0.275"MIN.
DISREGARD
STIFFENING UPS
(0.875 IN)2 (0.0188 IN -
)`
0.0188 IN + (0.875 IN -0.0188 IN)
2 _ _
y= 2
0.0188 IN x(2 x 0.875 IN -0.0188 IN)
y= 0.2258 IN
- (0.875 IN)3 ' 0.875 IN 2
IYVLEG =0.0188 IN X + 0.0188 IN x 0.875 IN x -0.226 IN
12r 2
= 0.0018 IN4-
(0.0188 IN)3 1 0.0188 IN- 2
IYVLEG =(0.875 IN-0.0188 IN) +0.875 IN-0.0188 IN)x0.0188 IN x 0.226 IN-
12 2
0.00076 IN4
ly= IYVLEG + IYVLEG— 0. 0.00254 IN4
Iy
Sy= = 0.0039 IN3
0.875 IN-0.226 IN
MCAP= x0.6 - >
Sy x 33 KSI -6.46 FT-LB 5.33 FT-LB ACTUAL-OK
ANGLE SPANS 24" BETWEEN STUDS
S-kS
SUSPENDED CEILING CALCULATIONS
LEWIS &
consulting engineers
11111
18660 s.w.boones ferry road
- tualatin,oregon 97062
' 503.885.8605 phone 503.885.1206 fax
VAN VLEET
---/V------.7-
incorporated
ANGLE FASTENING TO STUDS
•. •
24 LB MAXIMUM
.1..f..4
1
•R _.."77.'
2411
rtr`�"' . Fp
R _ _ #8 SCREWS
../kiel7. TO STUDS
RT= Rv= 24 LB MAXIMUM
TCAPACITY=226 LB/3.0= 75.3 LB
VCAPACITY=520 LB/3.0= 173 LB
24 24
INTERACTION: t = 0.457 <1 OK
75.3 173
#8 SCREW TO EACH STUD OK
s—io
Project Name: Light gauge Page 1 of 1
Model Condition 2 Date:12/12/2018
Code: 2012 NASPEC(AISI S100-2012] Simpson Strong-Tie®CFS DesignerTM 1.5.0.0
Reactions and Connections
i Number of Connectors Required at each Reaction: 1
No.of No.of
Simpson Req'd Req'd#
nom, I Strong-Tie screws to 12-14
Support Reaction(Ib) Connector stud Anchors
RI 0.00 No Solutions - -
R2 0.00 No Solutions - -
Total Vertical Shear Carried by Connectors(Ib): 0
Bridging Connectors-Design Method=AISI S100
Simpson Strong-Tie
Span/CantiLever Bridging Connector Stress Ratio
4.67
Span N/A -
Shear and Web Crippling Checks
Bending and Shear(Unstiffened): N/A
Bending and Shear(Stiffened): NA
Web Stiffeners Required?: No
t
Section: 162S125-33 Single C Stud Fy=33.0 ksi
Maxo= 114.0 Ft-Lb Moment of Intertia,I=0.07 inA4 Va=600.7 lb
Loads have not been modified for strength checks
Loads have been multiplied by 0.70 for deflection calculations
Reactions have been multiplied by 1.0 for opposite load direction for connection design
Flexural and Deflection Check
Mmax Mmax/ Mpos Bracing Ma(Brc) Mpos/ Deflection
Span Ft-Lb Maxo Ft-Lb (in) Ft-Lb Ma(Brc) (in) Ratio
Span 0.0 0.000 0.0 None 93.8 0.000 0.000 L/0
Distortional Buckling Check
Span K-phi Lm Brae Ma-d Mmax/
lb-in/in in Ft-Lb Ma-d
Span 0.00 56.0 123.4 0.000
Combined Bending and Axial Load Details
Axial Ld Bracing(in) Max K-phi Lm Bracing Allow Intr.
Span (lb) KyLy KtLt KL/r (lb-in/in) (in) load(lb) P/Pa Value
Span 115.0(c) None None 127 0.0 56.0 445.2(c) 0.26 0.26
SIMPSON STRONG-11E COMPANY INC. www.strongtie.com
S-1--\
SUSPENDED CEILING CALCULATIONS
LEWIS &
consulting engineers
L
18660 s.w.boones ferry road
tualatin, oregon 97062
503.885.8605 phone 503.885.1206 fax
VAN VLEET
incorporated
PROJECT:
Templeton Elementary-Condition 3, Level 1, Type 2
TYPE OF GRID: ACOUSTICAL CEILING
CERTAINTEED 15/16"TEE SYSTEM
CS 12-12-20
CS4-12-20
CS2-12-20
AXIOM CAS-004
DISTANCE FROM CEILING ACOUSTICAL GRID- MAX. DROP= 1.6667 FEET
TO STRUCTURE:
COMPRESSION STRUTS: SEE PAGE S-"2-1 FOR SUMMARY
DIAGONAL WIRE SPLAYS: 12 GA. 55 KSI 4 WAYS AT EACH COMPRESSION STRUT
VERTICAL HANGER WIRES: 12 GA. 55 KSI AT 4'-0" O.C. ALONG MAIN RUNNERS
STRUCTURE ABOVE CEILING: OPEN WEB JOIST
FASTENERS FOR SPLAY WIRES: 1/4" DIA. X 3" LAG SCREW W/EYE TO JOIST CHORD
PERIMETER WIRES IN EACH ORTHOGONAL DIRECTION, ONE END OF THE
AND ATTACHMENTS: CEILING GRID MAY BE ATTACHED TO THE CLOSURE ANGLE.
THE OTHER ENDS IN EACH HORIZONTAL DIRECTION SHALL
HAVE 3/4 INCH CLEARANCE FROM THE WALL AND BE
SUPPORTED BY AN ARMSTRONG BERC-2 SEISMIC
PERIMETER CLIP AT ALL MAIN AND CROSS RUNNERS. NO
PERIMETER WIRES ARE REQUIRED IN THIS INSTANCE. THIS
FRAMING OPTION MUST BE APPROVED BY THE LOCAL
AUTHORITY HAVING JURISDICTION.
STRUT AND SPLAY SPACING: 12'-0"X 12'-0" OR MAXIMUM 144 SQUARE FEET
SUSPENDED CEILING CALCULATIONS --\%,
LEWIS &
L
consulting engineers
18660 sw.boones ferry road
tualatin,oregon 97062
503.885.8605 phone 503.885.1206 fax
VAN VLEET
incorporated
CEILING MOUNTED LIGHT
FIXTURES, EGRESS LIGHTS, LIGHTING FIXTURES, EGRESS LIGHTING, SPEAKER, AIR
SPEAKER,AIR TERMINALS, TERMINALS, OR MECHANICAL SERVICES WEIGHING UP
MECHANICAL SERVICES, TO 56 POUNDS AND DIRECTLY SUPPORTED BY THE
AND OTHER CEILING CEILING GRID SYSTEM SHALL BE POSITIVELY
SUPPORTED EQUIPMENT: ATTACHED TO THE CEILING SYSTEM. ATTACHMENT
SHALL BE MADE WITH A MINIMUM OF 4 APPROVED
FASTENERS LOCATED WITHIN 3 INCHES OF THE GRID
INTERSECTIONS TO SUSPENSION MAIN RUNNERS, OR
TO CROSS RUNNERS WITH THE SAME CARRYING
CAPACITY OF THE MAIN RUNNERS. IN ADDITION TO
THE ABOVE GRID CONNECTION, FIXTURES WEIGHING
AT LEAST 20 POUNDS BUT NOT MORE THAN 56
POUNDS SHALL HAVE TWO 0.080 INCH (12 GAUGE
A.W.G.) HANGER WIRES CONNECTED FROM THE
FIXTURE TO THE CEILING SYSTEM HANGERS OR TO
THE STRUCTURE ABOVE. THESE WIRES MAY BE
SLACK. FIXTURES WEIGHING LESS THAN 20 POUNDS
DO NOT REQUIRE SLACK WIRES. FIXTURES WEIGHING
MORE THAN 56 POUNDS SHALL BE SUPPORTED
INDEPENDENTLY FROM THE STRUCTURE ABOVE
INDEPENDENTLY OF THE GRID SYSTEM WITH
APPROVED HANGERS. CABLE TRAYS, ELECTRICAL
CONDUIT, COMMUNICATION CABLE, AND OTHER
SIMILAR INSTALLATIONS SHALL BE SUPPORTED
INDEPENDENTLY FROM THE CEILING.
DESIGN SCOPE: STRUTS AND SPLAYS ARE NOT REQUIRED FOR CEILINGS IN
ROOMS LESS THAN 1000 SQUARE FEET IN AREA(IN AREAS
WITH THE SURROUNDING WALLS BRACED TO STRUCTURE).
ENGINEERING: LEWIS &VAN VLEET INC. HAS BEEN RETAINED TO DESIGN
THE CEILING GRID SUPPORT AND BRACING, AND
ATTACHMENTS FROM THE GRID SYSTEM TO THE
SUPPORTING STRUCTURE. IT IS THE RESPONSIBILITY OF
THE BUIDING OWNER, CONTRACTOR, OR ENGINEER OF
RECORD TO VERIFY THAT THE STRUCTURE HAS ADEQUATE
STRENGTH AND LATERAL STABILITY TO RESIST THE LOADS
IMPOSED ON IT BY THE SUSPENDED CEILING.
CODES: LEWIS &VAN VLEET, INC. HAS FOLLOWED THE STANDARD
PROVISIONS OF THE 2012 IBC, THE 2014 OSSC,AND ASCE 7-
10 IN THE DESIGN OF THIS SYSTEM.
SUSPENDED CEILING CALCULATIONS
LEWIS &
_1 Lconsulting engineers
18660 s.w.boones ferry road
tualatin,oregon 97062
"n 503.885.8605 phone 503.885.1206 fax
44
VAN VLEET
incorporated
LATERAL LOADING:CONDITION NO. 3, LEVEL 1,TYPE 2
SPECTRAL ACCELERATION SDS= 0.715
SITE CLASS= D
IMPORTANCE FACTOR Ip= 1.25
COMPONENT AMPLIFICATION FACTOR ap = 1
COMPONENT AMPLIFICATION FACTOR Rp= 2.5
CEILING WEIGHT w= 4 PSF
ATTACHMENT HEIGHT OF CEILING z= 16 FEET 1+2 *z/h = 2.000
AVERAGE ROOF HEIGHT h = 32 FEET
DESIGN FOR TOTAL LATERAL FORCE FOR A 12'X 12' GRID:
TOTAL WEIGHT: Wr = w* 12' * 12' = 576 LBS.
— w
LATERAL LOAD: Fp= 0.4*ap*Sps*Wp*0.7 2 *z
1 +
Rp/ 1p h r
Fp = 115 LBS. ASCE 7-10 ++ (EQ. 13.3-1)
MANDATORY LOWER BOUND: Fp = 108 LBS. ASCE 7-10++ (EQ. 13.3-3)
OPTIONAL UPPER BOUND: Fp= 577 LBS. ASCE 7-10++ (EQ. 13.3-2)
++ NOTE: 0.7 FACTOR IS APPLIED TO THE FORCES FOR ALLOWABLE STRESS DESIGN
S-2.0
SUSPENDED CEILING CALCULATIONS
LEWIS &
consulting engineers
LI
18660 s.w.boones ferry road
tualatin,Oregon 97062
503.885.8605 phone 503.885.1206 fax
SPLAY WIRE AND CONNECTION TO STRUCTURE: CONDITION NO. 3, LEVEL 1, TYPE 2
Strut Wire CEILING GRID 12 FT. X 12 FT.
45 deg.
Ceiling
CHECK DIAGONAL WIRE SPLAYS: 12 GA. Fy= 55,000 PSI A= 0.0088 SQ. IN.
CAPACITY OF WIRE: Tmax= 0.6 *Fy 8 *A
= 290 LB.
CONTROLLING SEISMIC FORCE: Fp DESIGN = 115 LB.
TENSION IN WIRE: T= Fp DESIGN/COS 45 DEG. = 163 LB. OK
1/4" DIA. X 3" LAG SCREW W/EYE TO JOIST CHORD
CHECK COMPRESSION STRUT:
1'-0"to 6'-0" use 1 5/8"-20 GA. STUD WITH 1 1/4" FLANGES
SSMA SECTION 162S125-33
-z!
Project Name: Light gauge Page 1 of 1
Model: Condition 3 Date:12/12/2018
Code: 2012 NASPEC[AISI S100-2012] Simpson Strong-Ties CFS Designer'M 1.5.0.0
Reactions and Connections
iNumber of Connectors Required at each Reaction: 11
�Ii No.of No.of
Simpson Req'd Req'd#
— N 1 Strong-Tie screws to 12-14
Support Reaction(Ib) Connector stud Anchors
R1 0.00 No Solutions - -
R2 0.00 No Solutions - -
Total Vertical Shear Carried by Connectors(Ib): 0
Bridging Connectors-Design Method=AISI S100
Simpson Strong-Tie
Span/CantiLever Bridging Connector Stress Ratio
1.67 Span N/A -
Shear and Web Crippling Checks
Bending and Shear(Unstiffened): N/A
Bending and Shear(Stiffened): NA
Web Stiffeners Required?: No
—
21
1
Section : 162S125-33 Single C Stud Fy=33.0 ksi
Maxo= 114.0 Ft-Lb Moment of Intertia,I=0.07 in"4 Va=600.7 lb
Loads have not been modified for strength checks
Loads have been multiplied by 0.70 for deflection calculations
Reactions have been multiplied by 1.0 for opposite load direction for connection design
Flexural and Deflection Check
Mmax Mmax/ Mpos Bracing Ma(Brc) Mpos/ Deflection
Span Ft-Lb Maxo Ft-Lb (in) Ft-Lb Ma(Brc) (in) Ratio
Span 0.0 0.000 0.0 None 114.0 0.000 0.000 UO
Distortional Buckling Check
Span K-phi Lm Brac Ma-d Mmax/
lb-in/in in Ft-Lb Ma-d
Span 0.00 20.0 123.4 0.000
Combined Bending and Axial Load Details
Axial Ld Bracing(in) Max K-phi Lm Bracing Allow Intr.
Span (Ib) KyLy KtLt KL/r (lb-in/in) (in) load(Ib) P/Pa Value
Span 115.0(c) None None 46 0.0 20.0 1506.0(c) 0.08 0.08.
SIMPSON STRONG-TIE COMPANY INC. www.strongtie.com
12/12/201,8
Design Maps Summary Report S-Z1...
Design Maps Summary Report
User-Specified Input
Report Title TemoEmry
Wed Decemberpletn 12le ,201$enta
17:01:14 UTC
Building Code Reference Document AE:
(whichSCutilizes7-10Standard USGS hazard data available in 2008)
Site Coordinates 45.41275°N, 122.77471°W
Site Soil Classification Site Class D - "Stiff Soil"
Risk Category IV (e.g, essential facilities)
"c a '-"-g `!• c .r ... „...,41,, rte—° Az„...7 z „,•k4„ ax :—.:. :7 x c -d
Xiii- ILr a-.. m x ,, • 4• .�.} ^- -t .awa's`f F...„-yam
a "Sa .ls ^r.-z. 4, M a-�b ' a.en ea,^+, � `y fF may,. .r c
...1 - �''• as s^^ »`:?cr_rs e;: .c-, ..
..cis cam. � -2 s. .x rs^ �
'71. e..p 9`m " L .., 4.t.:g. it' 4y-• . ma y y&.. -:_ ! '4 ......j' .'G�'�t r3: {'
w - r.t, ' -�-m.,-- i ..,. ,.r .r°kyr'. 9 r it7 x "a �.R
a sc rz.eel
•-it's'
,i. i ";rs. -'•'� a^ ..3 ,,,i..... x r, .tzs.y..s. .y xu,,at ' est wa"
•a� '- 'r�'.0 '� 3i s , -e. r'i bl_° «,} �. x11' 'w+ ams` g
tr:
'•� ice' s .a. Poi T �''..ik •,r•.. 't .r-^'.c"'t"3� }y n. i^a F- ... "� ,et.,a r
.-'-'::1.,.,,i'
"m gas's". �e y '.tea, {i. i r�' �� r �.m -i-r'5 si1;f:',: a-vrW..0-,
-t�'' lye5 T E R'e. 3^"" 'G I f A 3 " '4 ,..,.,,,,...._-=,•-•}F
'y . n � ill:- s.4t 1 .' ' ,rr. : rub"°z. W� ',Y.- .,Tea` y • r ' S$41, .
lk
4..,:... ..__iF� ia°,-.2„:„;?'�r „1.z.' ��'�k•a..-� +im��-�r t O� "��' -�-� 'hi. .�C.�-Z ?,fir 2 z c�".iS w�.�-+��
r k'" { • -x, ,3�« a1 rte:-se` i #tli , i Imo,:. �?-i s s .. N.^ e y*^x..
.---4,7-1-1,--_,
�.,y�
.. e"'S ,7 'FL'.i. h 'JLG.-..,.- i "L.R .5.43 4 Faye r„3. E 5 A:=74,7,',4:1
T -. •••.:.--4C0':.:4 ,1
..�? s. € °ry a... �'rxc.. r s'u 'r'-r... i 3'� r.
zs!r'sc•a .zrx sx.� �}. ,,�.r ?-�,r �i�. ms,
`4s ." sr� r a *t...7"1,4'•
�� ^.r w A" .*ws-ru.".�. spm a a -mt k,,mo
... �`�^'„u^ ,�' .tt '�'` y x vat .axe-x na �"r s s� ' �"�g'�-'' ro,
„e,'Tz1"..4 4;I 's y g 's^2 a.4 a^r3.t:f. 2 s r-
z "' te"1'.... ". ,r'r .� a"' Qeai� .;risme' aso .a. r'"`V;PZ
r :x. s.tT- ^a'11 e.4:14*,:‘ w r. ' s` f ,.,sem. -.7—:' y*e"^"
.. "ice a svq. -r ' R.: b c..`'', &' "'t
;keit- Y :. - e: °'."•s^+t ^-u,':" '?s'�G i ri^a��,. ',�- ..a rgp .. ..:.. rte... ._, '
USGS-Provided Output
S5 = 0.962 g SMS = 1.073 g SDs = 0.715 g
S1 = 0.420 g SM1 = 0.664 g SD1 = 0.443 g
tion on
For informahow the SS and Si values above have been calculated from probabilistic (risk targeted) and
deterministic ground motions in the direction of maximum horizontal response, please return to theapplication and
select the"2009 NEHRP"building code reference document.
1 itwG tt se Sp>?ctrum044
Design Response Spectrum
0.72
v
OW
u
h B_jy
E
TI0.44 0.23
ti 033
0,.12a,tee
0,17
0,0
0_I# vT�i
aixf
¢;k3 ir, P !.:.pa till ? ISO #. 3 1.40 I5i.'s #sa'i 2.03000 11„):i +.�.k; two ?t.7$:! #d}} #.. i #RG t# its »€>r
Palid.'1'(tt .Pried,T fsce?
For PGA,,,,, 11, C55, and Cal values, please view the detailed report.
Although this information is a product of the U.S. Geological Survey,we provide no warranty,expressed or implied, as to the
accuracy of the data contained therein.This tool is not a substitute for technical subject-matter knowledge.
haps://prod02-earthquake.cr,usgs.gov/designmaps/us/summary.php?template=mini mal&latitude=45.412750000000074&longitude=-122,77470999989... 1/1
�N f` x:e S,�„U c TU
;lir.
(cQ,F.D PROFFoINT tr
'Gin E. n r Q /'�{l5,99 O i
g R' C- 25 GA. X STUD WIDTH X 3” / r R E d .t
• `�Q N LONG
METAL TRACK EA. SIDE �r
�
N r
o - WITH 0) #S SCREW EACH LEG OPEN WEB 3oxs-r d � • ‘,``'�
- . z -HOLD TIGHT TO STRUCTURE 4 M E s
e
n v G]<
$P,1 z> I EXPIRES 12-31-2018 I
m TYPICAL HANGER WIRE
r WITH 1/4" DIA. X 3" LAG
N-1 �_. - SCREW WITH EYE
z v
n —I —I ` 1625125-33 LIGHT CSA. 1�
M a o �\1\, STEEL STUD
c7 m r1\X13 ril 12 GA. DIAGONAL WIRES
D O , – AT 45 DEG. MAX. TO PLANE
O
111
OF CEILING AND PARALLEL
y WRAP WIRE AROUND II ��/ It TO COMPONENTS (4 TOTAL
p rrn,. VERT. ELEMENT OF I II INAT L0 DEG, TO EACH OTHER
o Z rn JOIST. HAND WRAP 1 IN PLAN)
> WIRE WITH (3) 3604 Il f II
8 rn REVOLUTIONS MIN. I' ; n
c D TYP.,ALL DIAGONAL 11
�7 WIRES OR USE 0)Y4"� 45' MAX.I\l II , Il /f
0 -< X 3" LAG SCREW W/ \ II �\ II _ /�
EYE INTO BOTTOM
Nib II
CHORD U \I
*-------\
CROSS TEEMAIN RUNNER
1 (2)
#8 SCREWS
I
5373
E.1 SEISMIC BRACE 1�ETAIL - CONDITION #1, #2, #3
03
$$p PRo, .$
!� � �G I N ' S4-ii
.�---"n I 0 `-31 15,099 r
� ' I - n /
AL _
, if,,,'...14'.;/,1419,55° 4,
AA _--' v I �-. it i, 4A M E S v
lI if
I it [ EXPIRES 12-31-2018 1
8 MAX. P1 1'I Z 8" MAX PERIMETER
fir;+ HANGER
' - HANGER
7 WIRE
^ '' WIRE ,.L `
�+��C1TSSl CP�2�g
".t. : _ ' ; '
SEISMIC CLIP EK.�r„,\,,
7' y 3
,,..„--.--'7 �1 \ /!s
14415-15 WALL j !ell ::',.r.'':"-:,...; W4I5-I5 WALL ' ``fg t 41 TEE
TEE \-- i
MOLDING e t \! MOWING ,4,' / 1
ATTACHED WALL UNATTACHED WALL
Perimeter Wire �� I
±10° from vertical _l,t _ /1 Perimeter Wire
t
`�- ±10°from vertical
- I.,-- --__._.8" Max.---- , i.
.'. 8" Max.
CTSPC-2 \ `: /7 3/4"from grid to
I ,' inside of angle
i,
'11 ( ) 1 411111E0M11:
ji
CTSPC-2
I--- 15/16" Angle Screw optional
15/16" Angle---- —
CTSPC-2 CTSPC-2
TIGHT WALL. CLEARANCE WALL
INSTALLATION INSTALLATION
(ATTACHED WALL) (UNATTACHED WALL)
PROJECT: 12/13/18
LEWIS & VAN VLEET INC. w,
CONSULTING ENGINEERS TEMPLETON ELEMENTARY 18219
i.- 18660 sw boonea road TIGARD, OREGON
ll
ice
L. tualatln, on 4706
'= (503) 88505 phone D-2—2
(503) 885.1206 fox CLIENT: CASCADE ACOUSTICS
,
,,p PRO
.CMG I N 401 15,09'
I�s��J I
i
(*I,
it,
,...
,11A 'ES v_
1 EXPIRES 12-31-2018
STRUCTURAL NOTES:
1. ACCOUSTICAL AND GYPSUM CEILINGS
a. Main runners to be rated heavy—duty and have a minimum simple span rated uniform
load capacity of 16.35 pounds per lineal foot.
b. Space main runners at 4'-0" on center maximum.
c. Support grid system vertically and laterally from adequate building structure using #12
SWG galvanized wire per attached drawing details (4'-0" on center maximum along
main runners adjacent to cross tee intersections). Provide minimum of three turns of
hanger wire at end loop connections. Install lateral bracing as indicated In drawings
d. Use CTSPC-2 clips by CertainTeed to secure main runners and cross runners to walls
and perimeter trim per drawing details.
e. If cross runners supporting light fixtures are not the same carrying capacity as main
runners, provide supplementary hanger wires within 3 inches of each corner of each
fixture supported by cross tees. Light fixtures weighing not more than 10 pounds shall
have one #12 gauge hanger wire connected from the fixture housing to the structure
above. This wire may be slack and supplementary hanger wires are not required.
Lighting fixtures weighing more than 10 pounds but less than 56 pounds shall have in
addition to the requirements above, two #12 gauge hanger wires connected from the
fixture housing to the structure above. These wires may be slack. Lighting fixtures
weighing 56 pounds or more shall be supported directly from the structure above by
approved hangers. Supplementary hangers are not required. Pendant—hung light fixtures
shall be supported directly from the structure above using #9 gauge wire or an approved
alternate support without using the ceiling suspension system for direct support.
2. Per ASTM E580 Section 1.6, ceilings with areas less than 1000 square feet are exempt
from lateral force bracing requirements, and do not require splay wires or compression struts
when the surrounding walls are braced to the structure.
3. Suspended ceilings with areas less than or equal to 144 sq. ft. that are surrounded by
wails or soffits that are laterally braced to the structure above do not require perimeter wires.
SEISBRACE
LEWIS & VAN VLEET INC. PROJECT: 2/13/18
DATE
s GDNSULTING ENGINEERS TEMPLETON ELEMENTARY 18219
� `tt. 18660 sw boones ferry road TIGARD OREGON "'°a"°
-1!.-4.7.• tualatln, Oregon 97062 '
503 885.8605 phone
(503) 885.1206 fax CLIENT: CASCADE ACOUSTICS D-3
WET 03
FOR OFFICE USE ONLY—SITE ADDRESS: c7.,�0 O S) ill Gt-i e CS
This form is recognized by most building departments in the Tri-County area for transmitting information.
Please complete this form when submitting information for plan review responses and revisions.
This form and the information it provides helps the review process and response to your project.
City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT
Transmittal Letter
T I G A RD 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.tigard-or.gov
Cif-1 d 11 o c� Tom C
TO: ; DATE '� : 1, EAVED
DEPT: BUILDING DIVISION
DEC 18 2018
FROM: Mai CITY OF TIG.ARD
COMPANY:
T t'�t p t-e,��t` W�,11 man, T 4,.c ,
BUILDING DIVISION
PHONE: '5O-5 °I'LL `-t I s Z By:#9 j
RE: �5 a o s lnl nn vrd o c,k S+ , (gi g of t rS P, 9-4/1,9 �� D iif- az
ein
(Site Address) (Permit urn er
TerVip,et0 t1 E 14 t'Yl f rota{y S G h o d I
(Project name or subdivision name and lot number)
ATTACHED ARE THE FOLLOWING ITEMS:
Copies: Description: Copies: Description:
Additional set(s) of plans. Revisions:
Cross section(s) and details. Wall bracing and/or lateral analysis.
Floor/roof framing. Basement and retaining walls.
Beam calculations. Engineer's calculations.
Other(explain):
REMARKS: ' i i a U °a V a t d a f i °h 3 e Y(' d s L h c1+f ra t W r e- 0 Oil' t' -fp r -
Jeis itc, C{hL.(.ly :;o of 4Ve_ ACe flcr C illn� �unc1S
FOR OFFICE USE ONLY
Routed to Permit Technician: Date: Initials:
Fees Due: ❑ Yes ❑No Fee Description: Amount Due:
PL/9-A/ 21f/EcJ $;-PT6 •
Special
Instructions:
Reprint Permit(per PE): ❑ Yes o ❑ Done
Applicant Notified: f?A' Date: /?./3�///' Initials: --
fill 141 (v.
I:\Building\Forms\TransmittalLetter-Revisions.doc 05/25/2012