Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (36)
MEC-. \%-' CCO5U2 P C.-:\C)\ Sv QCML, S r. RECEIVED DEC 1 0 Z018 CITY OF TIGARD BUILDING DIVISION il JOHNSON \\AIR PRODUCTS1K0 ,,, .- -------,,,. ___,,,---- ±----'- I f__---- / SUBMITTAL Bldg. A Electric Heaters by Qmark Project: Oak Street Apartments (Tigard Apts) Project Address: 8900-9000 SW Oak Street Tigard, OR 97223 Architect: Kephart Engineer: System Design Consultants, Inc. General Contractor: AG Spanos Corporation Mechanical Contractor: Rite Way Heating and A/C Date: 6/13/2018 Project: Oak Street Apartments (Tigard Apts) Project ID: P17-1096 JOEINS ON PlICDDUC I '411111iiii1W Table of Contents Tab Submittal Spec/Sub Page# 1 Bldg. A Electric Heaters by Qmark Per MO.1 Electric Heater N/A Bldg A()mark CWH Series Heaters - Submittal - Oak 4 Bldg. A()mark MUH Series Electric Heaters - Submit 6 Project: Oak Street Apartments (Tigard Apts) Project ID: P17-1096 JOHNSON AIR PRODUCTS Spec Section: Per M0.1 Electric Heater Per MO.1 Electric Heater Schedule. Sub Section: N/A Submittal Name Bldg. A Electric Heaters by Qmark Vendor/Subcontractor Johnson Air Products Jason Elliott PRODUCT SUBMITTAL SHEET Capacities ® CWH1000 SERIES 0 A Marley Engineered Products Brand 500,562,750,900,1000, FAN-FORCED WALL HEATERS 1125,1500,1800 or 2000 Watts 120,12081240 or 277V @ 10 Only Thermostat Range:40°-85°F Air Movement:65 CFM Job Name: Oak Street Apartments (Tigard Apartments) Bldg. A Submitted By: Date: Location: Tigard, OR Jason Elliott 05/30/2018 Architect:Kephart Engineer: System Design Consultants Approved By: Date: Contractor: Rite Way Heating Submitted By: Jason Elliott Date: 05/30/18 Item QTY Catalog Tag Watts Volts PH AMPS Weight Number 1 5 CWH1208DSF EH-01 2000 208 1 9.6 N/A 0 ACCESSORIES - ----- immiimm w/Std.Integral Thermostat Part Item QTY Number a9 pial IIID IIUU �� (,) Marle fl Engineered Products Ip 470 Beauty Spot Road East I ----- Bennettsville, fBennettsville,South Carolina 29512 www,marleymep.com c�, us ZSS-QCWH2 I 9-2015 • Catalog Number Volts Amps Watts BTU/HR (Wire Size ,' ,r I --H , ,I CWH1101DSF 120 8.4/4.2 1000/500 3413/1706 14AWG s — CWH1151DSF 120 12.5/6.3 1500/750 5120/2560 12AWG Q. i 0 ,., .,x CWH1201DSf 120 15.0/7.5 1800/900 6143/3072 12AWG p 240 8.4/4.2 2000/1000 6826/3413 14AWG0 CWH1202DSF , _ 208 7.3/3.6 1500/750 5120/2560 14AWGpo7rTern IT! 27941m 12-Nr" �r CWH1207DSF 277 7.3/3.6 2000/1000 6826/3413 14AWG I 240 6.3/3.2 1500/750 5120/2560 14AWG , € « ; E 277 5.5/2.75 1500/750 5120/2560 14AWG . CWH1157DSF t s' r 240 4.7/2.4 1125/562 3840/1920 14AWG g. CWH1208DSF 208 9.6/4.8 2000/1000 6826/3413 14AWG """ Accessories I i 9.1=1 I 135 CWHSM —"II face Mounting Frame(Accessory)Order Separately- . 'r ite . .., ..r..., ""1 12-1/2" : • .X 10-3/8"(264mm) r mm) i' 1, CWHS1 1"(25mm)Recess Mi • ' . r. , essory)Order Separately-Northern White 1 CWHS2 " ,s 'ecess Mounting Frame(Accessory)Or.• .• ,tely-Northern White _._.__ IT 7"T '' Tamper-resistant front cover-Northern White """- pip ~/...1422,-..1 Standard color is Northern White. ARCHITECT'S AND ENGINEER'S SPECIFICATIONS* w/Std.Integral Thermostat The heating equipment shall include an electric automatic MOTOR AND CONTROLS: The fan motor shall be impedance fan forced air heater suitable for small area heating,as protected,permanently lubricated.Fan control shall be of manufactured by QMark®,a Marley Engineered Products® the bi-metallic,snap-action type and shall activate fan after Brand,Bennettsville,SC. The heater shall be designed for wall heating element reaches operating temperature,and continue mounting,recess or surface. Heaters shall be cETLus listed. to operate the fan after the thermostat is satisfied and until all heated air has been discharged.The thermostat shall be BACK BOX: The back box shall be designed as a recessed single-pole type on all models.Thermal cutout shall be self- rough-in box in either masonry or frame installations and is hold(manual-reset)type designed to shut off heat in the event also used when surface mounting frames are used in surface of overheating.The fan shall be four-bladed aluminum.A back- mounting installations. The back box shall be heavy gauge galvanized steel and shall contain knockouts through which up(End of Life)thermal fuse shall be provided for additional safety. power leads enter. SURFACE MOUNTING FRAME: The surface mounting frame INNER FRAME ASSEMBLY: The heater assembly,which fits shall be of heavy gauge steel designed to mount around the into the back box,shall consist of a heavy gauge steel fan back box for a finished surface installation.Slot knock outs panel to which all of the operational parts of the heater are shall be provided for power supply conduit. mounted.The inner frame assembly shall be completely pre- wired. FRONT COVER: The louvered front cover shall be of heavy gauge steel with a powder paint finish. A plug button will be HEATING ELEMENT: The heating element shall be of the provided to replace the thermostat knob and render the unit non-glowing design consisting of an 80/20 nickel-chromium tamper-resistant. resistance wire enclosed in a steel sheath to which plate fins are copper brazed.The element shall cover the entire air FINISH: All sheet metal parts,except the galvanized steel discharge area to ensure uniform heating of all discharged air. back box,shall be phosphatized,then completely painted by a It shall be warrantied for 5 years. powder paint process. ON/OFF SWITCH: A double-pole,single throw on/off switch *In the interest of continual improvements in product and performance, shall be mounted on the back box for positive disconnect of Marley Engineered Products reserves the right to change specifications power supply. It will be completely concealed behind the without notice. front cover. 0 ZSS-QCWH2 I 9-2015 SUBMITTAL SHEET E 111 ® _,,..-.--- --- MUH SERIES = miARK® HORIZONTAL VERTICAL A Marley Engineered Products Brand = CA gi,W W MARK® .2-speed fan selector switch(25 to 50 KW models). Ca A Marley Engineered Products Brand . Fan delay feature eliminates cold drafts. Element heats up = 470 Beauty Spot Rd.E,Bennettsville,SC 29512 = visit www.qmarkmep.com for more info before fan cuts in,then fan continues to distribute heat after element shuts off. ARCHITECT'S AND ENGINEER'S SPECIFICATIONS* . Ruggedly built,yet lighter weight for easier installation. No • Unit mounts either horizontally or vertically.Totally versatile.For factories, piping flutes,valves,or traps. warehouses,garages,stores,shipping rooms,power stations.Can be used for • Individually adjustable discharge louvers to control air flow. primary,supplementary,spot,or dual-system heating. .Choice of optional diffusers for variety of air patterns, •Wide range of optional control kits are field installable,increasing the MUH maximizing heat concentration and coverage in the vertical adaptability to the specification market. position. • Forced air unit heater with 10 power ratings;from 3KW to 50 KW heating output; • Meets all UL,NEC,and OSHA requirements. 208,240,277 and 480V, 10,230 to 170,500 BTU/hr, q •32 compatible models(no need to try to assemble a heating system from 70 or 80 models!) • Heavy gauge die-formed steel housing.Two-toned,smartly styled with stainless steel louvers. •Advanced pull-through air flow design draws air across heating element for more even air distribution and cooler element operation. ,�•!►►"� H • Specially designed venturi outlet to meet that added throw as required in vertical `± position. .....-- • Branch circuit fusing(when required). • Completely enclosed fan motor. • 1-or 3-phase wiring on 5 through 10 KW 208/240V and 15 KW 208V units(field interchangeable). •Aluminum-finned,copper clad steel sheath heating element has longer useful o\ /W life,because of cooler sheath temperature and faster heat dissipation. DIMENSIONS \ ''./" •24V control transformer standard on most models,providing a safer and moreCAT.NO. I HEIGHT I WIDTH I DEPTH I accurate means of temperature control.3KW and 5KW,208-277V,have line 1 MUH-03 95 16" 14" EMI voltage controls as standard(24V control available on made-to-order basis). MUH-07&10 213/4" 19" 71/2" •Automatic reset linear thermal cut-out,capillary type,provides protection over MUH-15&20 213/4" 19" 123/4" entire length of element areas(Manual reset protection available on made-to- MUH-25&30 30" 26518" 113/4" order basis). MUH-40&50 30" 265/8" 171/8" SELECTION CHART ELECTRICAL DATA 2 S.I. AIR DELIVERY DATA FAN MOTOR DATA MAXIMUM EFFECTIVE HORI. E TA J D ...., WEIGHT CAT.NO. VOLTS PHASE I......KW I VOLT commixES HEIGHT wiRE.,10.2 14.5 208 WA _... � 800... 27°.. 18 1600..... 11r. ....:....8 9 1 AW 12 27,._... UH03-21......208240 10 2.2/3.0 7.5/102 11.0/12.5 208/240 N/A 350 800.... 27'....... 208/240.... 1600....... 1/100 8 9 12 AWG 12 27 `.,.• 71 277 10 3.0 10.2 11.0 277 N/A 350 800 27° 277 1600 1/100 8 9 12 AWG 14 ` MUH' 347 10 3.0 10.2 8.6 24 N/A 350 800 27° 347 1600 1/100 8 9 12 AWG 1•.- 27 MUH0341 480 30 3.0 10.2 3.6 24 N/A 350 800 27' 480 1600 1/100 8 9 12 A S'4 27 MUH0381 .•. 30 3.0 10.2 2.9 24 WA 350 800 27° 600 1600 1/100 8 9 12 - G14 27 MUH05-81 208,,,. 1-30 5.0 17.0 24.0 208 5A 350 800 45° 208 1600 1/100 8 9 AWG 10 27 MUH05•21 208/240 9 3.7/5.0 12.6/17.0 18.0/21.0 208/240 5A 350 800 45° 208/240 1600 1/100 8 9 12 AWG 10 27 MUH05-71 277 10 5.0 17.0 18.0 277 N/A 350 800 45° 277 1600 1/100 8 ,+ 12 AWG 10 27 MUH0531 347 10 5.0 17.0 14.4 24 N/A 350 800 45' 347 1600 1/100 8 9 12 AWG 10 27 MUH0541 480 30 .:... 17.0 6.0 24 N/A 350 800 45' 480 1600 1/100 8 9 12 AWG 14 27 MU1105.61 600 30 50 17.0 4.8 24 N/A 350 800 45' 600 1600 1/100 9 12 AWG 10 27 MUH-078 208 1-30 7.5 - '`• 36.0 24 5B 650 970 37° 208 1600 1/30 9 14 18 AWG6 38 MUH-07-2 208/240 1-30 5.6/7.5 19.125.-- 27.0/31.3 24 5B 650 970 37' 208/240 1600 -4 9 14 18 AWG8 38 MUH-07-7 277 10 7.5 256 7.0 24 5B 650 970 37° 277 1600 ' 1/30 9 14 18 AWG 8 38 MUH-07-3 347 10 7.5 25.6 2'x.. 24 5B 650 970 37° 347 1•+,c 1/30 9 14 18 AWG 14 38 MUH-07-4 480 30 7.5 25.6 9 0 24 58 650 970 37° 480 -- r 1/30 9 14 18 AWG 14 38 MUH-07-6 600 30 7.5 25.6 7.3 4 58 650 970 37' 600 1600 1/30 9 14 18 AWG 14 38 MUH-10-8 208 1-30 10.0 34.1 48.0 24 5B 650 970 49' .>.: 1600 1/30 9 14 18 AWG 4 38 MUH-10-2 208/240 1-30 7.5/10.0 25.6/34.1 36.0/420 24 B 650 970 49° 08/240 1600 1/30 9 14 18 AWG6 38 MUH-10-7 277 10 10.0 34.1 36.0 24 55' 650 970 49 277 1600 1/30 9 14 18 AWG6 38 MUH-10.3 347 10 10.0 34.1 28.8 24 58 650 970 •'•° 347 1600 1/30 9 14 18 AWG 14 38 MUH-10-4 480 30 10.0 34.1 12.0 24 58 • 970 49° 480 1600 1/30 9 14 18 AWG 14 38 MUH-10-6 600 30 100 34.1 9.7 24 58 •' 49° 600 1600 1/30 9 14 18 AWG 14 38 MUH-158 208 1-30 15.0 51.2 72.0 24 5A 910 r 52' 208 1530 1/20 11 20 35 AWG 2 53 MUH-15-2 208/240 30 11.2/15.0 38.2/51.2 31.3/36.1 24 5C 9 1.•• 52° 208/240 1530 1/20 11 20 35 AWG 6 53 MUH-154 480 30 15.0 51.2 18.0 24 5C •10 1640 ..52' 480 1530 1/20 11 20 35 AWG 10 53 MUH-19-6 600 30 150 51.2 14.5 24 5C 910 1640 600 1530 120 11 20 35 AWG 12 53 MUH-20-8 208 30 20.0 68.2 56.0 24 A 1320 2060 48°.,... 208 1500 1/10 12 23 41 AWG4 60 MUM-20-2 208/240 30 15.0/20.0 51.2/68.2 412/48.0 24 5C 1320 2060 48' •'.••40 1500 1/10 12 23 41 AWG4 60 MUH-204 480 30 20.0 68.2 24.0 ^' 5C 1320 2060 48' 480`• 1500 1/10 12 23 41 AWG 10 60 MUH-20-6 600 30 20.0 68.2 19.3 24 5C 1320 2060 48' 600 1500 1/10 12 23 41 AWG 12 60 MUH-25-2 208/240 30 18.725.0 63.8/85.2 52.0. . 24 5A 2100/1800 21002030 38'/44' 208240 1.e 1/4 13 23 50 AWG 3 93 MUH-25-4 480 30 25.0 85.2 •.0 24 5C 2100/1800 2100/2030 38'/44' 480 1600/1375 1/4 13 23 50 AWG8 93 MUH-256 600 30 25.0 85.2 24.2 24 5C 2100/1800 2100/2030 38°/44° 600 1600/1375 .... 13 23 50 AWG 10 93 MUH-30-8 208 30 30,0 ..3 84.0 24 5A 2100/1800 2100/2030 45'/53° 208 1600/1375 1/4 12 20 50 AWG 1 93 MUH-30-2 208/240 30 22.530.0.. 6.7/102.3 63.0/72.3 24 5A 2100/1800 2100/2030 45'/53° 208/240 1600/1375 1/4 20 50 AWG 2 93 MUH-304 480 30 •. 102.3 36.0 24 5C 2100/1800 2100/2030 45'/53° 480 1600/1375 1/4 12" 20 50 AWG6 93 MUH-30-6 600 30 •.0 102.3 29.0 24 5C 2100/1800 2100/2030 45'/53' 600 1600/1375 1/4 12 20 50 AWG8 93 MUH-40-2 208/240 0 30.0/40.0 102.3/136.4 83.4/96.4 24 5A 3000/2600 3260/2900 42'/49' 208/240 1025/1420 1/2 15 2:' 60 AWG1/0 114 MUM-40.4 480 0 40.0 136.4 48.0 24 5A 30002600 3260/2900 42°/49' 480 1525/1420 1/2 15 28 60 AWG 4 114 MUM-40-6 600 30 40.0 136.4 38.7 24 5A 3000/2600 3260/2900 42'/49' 600 1525/1420 12 15 28 5. AWG 6 114 MUH-50-8 -.8 30 50.0 170.5 139.0 24 5A 3000/2600 3260/2900 53'/61° 208 1525/1420 1/2 15 25 60 4/0 114 MUH-SO-.'208240 30 37.5/50.0 127.3/170.5 104.2/120.4 24 5A 3000/2600 3260/2900 53'/61' 208/240 1525/1420 1/2 15 25 60 AWG.'.. 114 MU - 480 30 50.0 170.5 60.2 24 5A 3000/2600 32602900 53'/61' 480 1525/1420 1/2 15 25 60 AWGM1 114 . .• 600 30 50.0 170.5 48.3 24 5A 30002600 3260/2900 53'/61' 600 1525/1420 1/2 15 25 60 AWG 3 1 Note: 1. All standard units are supplied with a low voltage control transformer and contactor(24V)except 3. On dual phase units,maximum amp draw is listed for respective voltage. MUH-03&05,208,240&277 volt models.Low voltage control on these units are available on made 4. 25 thru 50 KW models have two speed motors and dual CFM ratings. to order.All units are also available on special order for 120 volt control;internal and transformer or 5A Standard. external without transformer. 58. Optional-made to order-amp load unbalanced on 3 Phase. 2. On dual voltage units;CFM,FPM,and RPM are shown at higher voltage. 5C.Optional-made to order-amp load balanced on 3 Phase. MUH SERIES UNIT HEATER N14 DIMENSIONS w .{ - D• ---01CATALOG NO. HEIGHT(IN) WIDTH(IN) DEPTH(IN) y MUH038.95- 16 14 7-1/2 -------•/ MUH07&10 21-3/4 19 7-1/2 --------/ H MUH15&20 21-3/4 19 12-3/4 "-MUH25&30 30 26-5/8 11-3/4 :_:-.0 ) J MUH40&50 30 26-5/8 17-1/8 _z OPTIONAL FIELD-INSTALLED CONTROLS CATALOG NO. UPC DESCRIPTION ELECTRICAL RATING COMPATIBLE WITH y. UHMT1 6 8536015241 7 Single Pole Internal Thermostat-Temp 25A©120,240VAC Res. All MUH Series Heaters Range:40°-85°F 22A©277VAC Res. (except MUH0521 3 PH,MUH0581 3 PH which use UHMT2) Two Stage Internal Thermostat-Temp 25A®720,240VAC Res. MUH0521 3 PH,MUH0581 3 PH,MUH1 58,MUH2O8,MUH252,MUH302, U' 2 6 85360 15242 4 Range:40°-85°F 22A @ 277VAC Res.125VA MUH308,MUH402,MUH404,MUH406,MUH502,MUH504,MUH50• MUH508 MCFS 6 85360 04637 2 Internal Summer Fan Switch 250,480, Pilot Duty 6A,600VAC Res.2 HP All MUH Series Heaters 600V.A.C.1,2 OR 3 PH MRFS1 6: 60 04708 9 Remote Summer Fan Switch(Line 2 HP,250-480VAC All MUH Series Heaters Voltage) MRFS2 6 85360 0 6 Remote Summer Fan Switch with Relay 6 AFL,35 ALR,250VAC,60Hz All MUH Series Heaters(except MUH0321 0 0371,MUH0381,MUH0521, (24V Coil-Single Pole Normally Open) 3 AFL,18 ALR,480VAC,60Hz MUH0571,MUH0581)Units unless o.' al control transformer is supplied Heat Recovery Thermostat with Relay 6 AFL,35 ALR,250VAC,60Hz All MUH Series Heaters(exce. 010321,MUH0371,MUH0381,MUH0521, MHRT 6 85360 04694 5 4V Coil-Single Pole Normally Open)Hi- 3 AFL,18 ALR,480VAC,60Hz MUH0571,MUH0581)Uri /nless optional control transformer is supplied 120°F,Low-60°F MUH0321,MUH034 • H0371,MUH0381,MUH0521,MUH0541,MUH0571, MPDS25 6 85360 04703 4 Power DI•-rnnect Switch(3-Pole) 30A CO 600VAC,Res. MUH0581, 073,MUH074,MUH076,MUH104,MUH106,MUH154, MUH156,MUH2O4,MUH2O6 M -. 2,MUH077,MUH078,MUH102,MUH103,MUH107,MUH108, MPDS60 6 85360 047041 Power Disconnect Swi.•(3-Pole) 80A Q 600VAC,Res. H152,MUH2O2,MUH2O8,MUH252,MUH254,MUH256,MUH304, MUH306,MUH404,MUH406,MUH504,MUH506 NOTE:Any field installed options assembled in the factory require added surcharge. •• •ice book for charges.MPDS60 disc, ect switch is not suitable for field installation on 7.5kw and 10kw unit heaters. DIFFUSER SELECTOR TABLES FOR VERTICAL MOUNTiNC -- i I MAX. I CATALOG MOUNTING NO. I DESCRIPTION CATH•nr_NO HEIGHT (A)n.' ENS!ON DIFFUSER PATTERN AND AREA - NONE H03&MUH05 9 18 2` DIFFUSER NONE MUH07&MUNI 0 14 NONE WITHOUT DIFFUSER MUH15 20 111111111111111111111111 NONE No diffuser needed where a straight down': MUH20 P3 35 40 -IIIII'IIIII'I" air pattern is required.For maximum. row, 111 ill NONE remove louvers.Any of three diff can be MUH25 23 63 55 111111111111 NONE added to basic he- . MUH30 20 NONE MUH40 28 70 63 NONE MUH50 25 MLDS MUH03&MUH05 9 25(A) 12(8) MLDM & 8) MLDM LOUVER DIFFUSER MUH MUH15UH10 14 50(A) 25(B) MII r MLDM Pe• directional(straight line)air flow as in air MUH2O 20 56(A) 28(B) IIIIIIIIIIIIHIIII it. A B urtain application over doorways.Rectangular IIIIIIIIIII MLDL MUH25 23 coverage,Louvers can be turned in either direr- MUH30 20 72(A) 36(8) MLDL tion. VDMUH40 24 88(A) 44(B) L MUH50 22 80(A) 40(B) J MUH SERIES UNIT HEATER OPTIONAL MOUNTING BRACKETS BRACKET SIZE DIMENSION 3-20 kW(IN.) 25-50 kW(IN.) ri CATALOG NO. UPC COMPATIBLE WITH ( SHIP WT.(LBS) A 7-1/4 9-7/16 B10 6 85360 15229 5 MUH03-10 8 B 9-1/2 14-3/8 ' 0 6 85360 15230 1 MUH15&20 10 C 7-1/4 12-1/8 Bar 6 85360 15231 8 MUH25&30 13 D 11-5/16 2-1/16 E 2-1/4 3 B50 6 85360 15232 5 MUH40&50 15 L 20-1/2 28-15/16 M 9-15/16 14-15/16 N 3-1/4 4-1/2 OPTIONAL CEILING MOUNTING BRACKETS s. INNI CATALOG NO. UPC COMPATIBLE WITH SHIP WT.(LBS) 1111 CM610 6 85360 15236 3 MUH03-10 3 ill.CMB20 6 85360 15237 0 MUH15&20 4 CMB30 6 85360 15238 7 MUH25&30 5 CMB50 6'536015239 4 MUH40&51 6 \ \ I _ \ I OPTIONAL VERTICAL CEILING MOUNTING BRACKETS ► i lizotmEr CATALOG NO. UPC COMPATIBLE WITH SHIP WT.(LBS) VDMB5 6 85360 15245 5 Fr MUH03-05 5 MN VDMB20 6 85360 15246 2 MUH07-20 7 VDMB50 6 85360 15247 9 MUH25-50 9 MOUNTING LIMITATIONS:Unit heaters should not,•used in potentially explos e atmospheres.The finish is not intended for direct salt spray exposure in marine application or the highly corrosive atmosp es of swimming pools,chemical storage bins, E etc.Do not install unit heaters above recom • ded maximum mounting height.I: tructions must not block unit heater air inlet or discharge.Heaters must be mounted at '.st 7 ft.above the floor to prevent acci.. tal contact with the heating element or fan blade which could cause injury. A L FACTORY-INSTALLED OPTIONS FOR CONTROLS&ACCESSORIES 1-1/2" DESCRIPTION �- MUH03&05(208,208/240,277V Supply) 24 or 120V Control Transformer and Power Contactor D 24 or 120V H.C.Power Contactor M MUH03&05(480V Supply)&MUH07 thru MUH50 = Optional 120V Control N C 2-Stage Control of Elements(See Note 5) Manual Reset „Th3/4• Outlet Mesh(Bird Screen)For all MUH Heaters 44:i, \r NOTE:Any factory-installed options require added surcharge.See price book for charges or contact factory. 1-1/2”