Loading...
Report (32) � .:: DEC 1 ® 2018 YAWCIIY OF` IGAf D BUILDING DIVISION Submittal Date: November 8, 2018 Customer: Rite-way Heating & Air Project Name: Oak St. Tigard Engineer: SDC Location: Tigard, Or Spec Section: Rooftop Air Handling Equipment Johnson Barrow respectfully submits the following equipment for review: Product Tag Qty. Model Manufacturer Rooftop Air Handling HRV 4 MCV1000E York Equipment General Notes: • This submittal is for approval. Approval is required in order for equipment to be released for fabrication Submitted By: Rudy Caffall Andrew Murphy Johnson Barrow Oregon Johnson Barrow Oregon Dr-ear/Cad: 503-260 0439 Oi ecgiCell: 503-758-8703 Email; RudyC@JBarrow.com Ernoil. AndrewM@jbarrow.com Sign Date Approved as Noted Approved with Comments Revise and Re-submit 735 SW 20 " Place 230 , Portland , OR 97205 PHONE (971) 717-7123 jBa mN Submittal Contents Scope of Offer and Clarifications 3 Unit Performance 4 Unit Dimensional Drawing 5 Electrical Notes and Wiring Diagrams 6 Unit Written Specification 7 Warranty 8 735 SW 2Oth Place 230 , Portland , OR 97205 PHONE (971) 717-7123 ) = -) 1 Submittal _.A Scope of Offer and Clarifications Scope of Supply: • (4) York heat recovery units • Horizontal OSA and exhaust, horizontal discharge and return for indoor mounting • DWDI fans with EC Motors o Factory mounted o 208V/l ph • Plate Heat Exchanger • 2" MERV 8 o Clogged filter sensor • Disconnect • Pressure relief and Intake Hoods,with backdraft damper for exhaust and motorized damper for OSA roof opening. • 1-year parts warranty Exclusions: • Offloading,storage, access, rigging, and installation by others • Controls and sensors by others • Seismic Calculations by others • Dampers or actuators not included 735 SW 20th Place 230 , Portland , OR 97205 PHONE (971) 717-7123 ,---- - z:}yiiii.',. . ;,;_ee/- ORE ON Submittal Unit Performance 735 SW 20th Place 230 , Portland , OR 97205 PHONE (971) 717-7123 4„ ,tri: 4-,A YORK :„. ,„,,:.,:u ,,. ,„. , , ,. MINICORE VENTILATOR UNIT MODEL: MCV1000E ARRANGEMENT:STANDALONE MINICORE CFM RANGE: 1250-500 CFM MCA: 15.075 UNIT VOLTAGE: 230V MOCP: 20 DUCT CONFIGURATIONS RETURN AIR DUCT OPTION 1 --I-- -1"-- RETURN AIR I I --,,,,,,„-------- , ,----igt ---1,--- I OUTSIDE AIR I -' '`"'-- INTAKE r-- '----„,,_ ----- --re- -,<---- .">1 ,...'",- ---, I 11.414-,4,1t:''''- •---'>- I „L, . •----->--- ITT;-.l< ..,,..„ - , .<1.1-' I • ' -'-'-' , _-_-- .-.. --,, <-4-0 -- • I --,_.' „,, 1 --1- ,--- ,,,,, Q`• i ---- I - -,-.-;< ----:1;‹,, I 1 ,,, OUTSIDE AIR L 1---- ,------- • INTAKE '-:---' 111- ' ).<-..,,. 66-....:........, ''' , I - --- FRESH AIR ------.' - I -4- SUPPLY ----- , "r--'----, DUCT OPTION 2 1 ----- -•`-, 1 >I ------, I ----- --I-- EXHAUST AIR FILTERS QUANTITY . .:;', ,;'..' TYPE ;:' .i;., '-' '::-';} ' SIZE(EACH) INTAKE: 1 2” PLEATED 20x20 EXHAUST: 1 2" PLEATED 20x20 PERFORMANCE fA QTY UNIT# AIRSTREAM FLOW(CFM) SP(INWC) 1 MCV1000E SUPPLY 500 1.00 EXHAUST 500 1.00 MOTOR AIRSTREAM HP VOLTS/PHASE ft TYPE ff; DRIVE FLA Supply 0.75 230V/1Phase ODP DIRECT 6.7 Exhaust 0.75 230V/1 Phase ODP DIRECT 6.7 K , al i YO R SUMMER AND WINTER PERFORMANCE INPUTS FOR YOUR SITE Summer ,, _ Winter Outdoor(EA) Return(RA) Outdoor(EA) Return(RA) Airflow/s[CFM] 500 500 500 500 Dry bulb temperature[F] 91.2 75.0 23.9 72.0 Wet bulb temperature[F] 67.5 63.0 22.9 54.0 Condensation No No No No Relative humidity(RH)[%] 28.81 51.62 86.79 28.78 Enthalpy(H)[BTU/lb] 31.9 28.5 8.2 22.6 Moisture Ratio(MR) [grains/Ib] 63.1 67.0 15.8 33.5 Energy(Q)[BTU/hr] 109,601 98,123 28,115 77,600 Exhaust(EA) Supply(SA) Exhaust(EA) Supply(SA) Airflow/s[CFM] 500 500 500 500 Dry bulb temperature[F] 86.0 80.2 39.5 56.5 Wet bulb temperature[F] 66.2 64.4 35.3 44.9 Condensation No No No No Relative humidity(RH)[%] 34.91 42.32 66.53 37.75 Enthalpy(H)[BTU/Ib] 30.9 29.5 13.2 17.6 Moisture Ratio(MR)[grains/Ib] 64.8 65.3 23.7 25.6 Energy(Q)[BTU/hr] 106,179.1 101,545.0 45,266.4 60,448.4 ENERGY SAVINGS FOR YOUR SITE Summer Winter Supply pressure drop [in w.c] 0.317 0.317 Exhaust pressure drop [in w.c.] 0.723 0.723 Sensible effectiveness [%] 67.9 67.9 Latent effectiveness[%] 55.2 55.2 Total effectiveness[%] 65.3 Supply air face velocity[ft/s] 262.7 262.7 Exhaust air face velocity[ft/s] 262.7 262.7 Moisture removed [grams/Ib] 1.08 4.82 Total energy saved [tons or BTu/hr] 0.67 tons `: 32,333 BTU/hr Temperature ratio 67.85 67.85 Water transfer ratio 55.19 55.19 Energy balance [%] 0.00 0.00 Water balance [%] 0.00 0.00 GENERAL SPECIFICATION MiniCore Ventilator Dimensions Duct size(in) CFM Voltage Fuse amps Phase (L x W x H)(in) (v) (A) Supply Return MCV1000E 44.25 x 42.25 x 20.66 12"x 6" 12"x 8" 500 1000 208-230 20 1 FILTER MiniCore Ventilator Series Filter Type Dimensions(in) Filter type Dimensions(in) MCV1000E MERV 13 20 x 20 x 2 Throw away 20 x20 x 1 ELECTRICAL MiniCore Ventilator series Voltage In(Vac) MCA* MOCP* MCV1000E 230 15.75 20 BLOWER MiniCore Ventilator Series Motor Wheel size Motor speed No.of Motor type Horse Power (dia x width) (s) Blowers (inches) MCV1000E 3/4 DD 9 x 6A 2(Modulating) 2 Electronically Commuted Motor Submittal Unit Dimensional Drawing 735 SW 20th Place 230 , Portland , OR 97205 PHONE (971) 717-7123 AIR FLOW NOMENCLATURE • .-..,,,,,,,,. '4:-..t. F5Y 2 ,;ii.,'''A , .-4 11:,t,..;-.'''''''', it',.':t:7-;.:1** ,461 ar--,'„0 "OR ZONTA` 5EDE VPRI.C:, MCV1000 Series a.k.a.01xH/E-21 • MCV1000 Standard model includes—(Permanent Split Capacitor Motor, Blowers and Static Core) • MCV1000 E—(Electronically Commuted Motor, Blowers and Static Core) Dimensions MCV1000E - 44.250 - - 42 240 - 4 :x iG r` € C1 0 [II! tit' 0: i j "',,,, V' s"`, a ;.. 4.608 - - 2.072 4:081 6.400 - ..�___12,000 - 6.000 - - 8.226 _ {ham. S if i *a KeJob: Tigard Apts. Company: Johnson barrow Oregon Project: Sales Person: Luis Ortiz SVC Quantity: 4 Roof Mounted Spun Aluminum Gravity Ventilator (Curb Base) Special: None Product Image SVC – Spun Aluminum Gravity Rooftop exhaust(relief)or supply (fresh air)ventilator shall be Weather Cap WCC(curb t i r— - , Constructed of a heavy-gauge spun aluminum dome,aluminum base and airshaft,and galvanized internal bracing. Dome 6 ei o Airshaft overlaps base venturi and is sealed to prevent s + water entry. Dome fasteners are sealed and dome is easily i. AIIIIIIIIIIIIIIL removable a r_ A B C E sqr F H L Damper sqr Ship Volume 9 1.5 5.5 18.5 4 11 18.5 11.25 4 Weight Throat Area Throat Vel Pressure Drop HoodVelocity 8 0.4418 1132 0.173 390 Options or Accessories Listing Unit Size 08 Special Option 0-None Application E-Exhaust Damper Type BDD-Back Draft Damper Schedule ID Quantity Tag CFM Static Pressure Roof Pitch Dim by 12 1 4 ERV-EXH 500 0.2 0 Page 1 of 1 - Edge Version 2014.0.420 - Product Information is Subject to Change without notice Job: Tigard Apts. Company: Johnson barrow Oregon , 04 yo R K Project: Sales Person: Luis Ortiz Back Draft Quantity: 4 Gravity Operated Back Draft Damper Special: None Product Image Back Draft 4 3/4• _ •Sensitive and responsive to low velocities MAX.__,.,__. P up OPEN , -1 ' 1;it• _ __Damper Width _ to 1500 FPM range. I ,--.0276 STEEL BRACKETS- . 1 ' FRAME i •Square galvanized steel frame, •Multi-leaf, roll formed aluminum blades; ALUM. .. Sy BLAO[)ES M LN with TIE ROD _ 'Nylon bearings;and 1 SHOULDER RIVETSAr 14 •Felt Edges for quiet operation ft 1/8"DIA. a I --FELT GASKET Y .046 THICK d `-BOTTOM ANGLE 20 GA GALV STEEL Options or Accessories Listing Model Parent 0-Not an accessory Duty L-Light Application E-Exhaust Curb Parent 0-Not an accessory Schedule ID Quantity Tag 1 4 ERV-EXH Page 1 of 1 - Edge Version 2014.0.420 - Product Information is Subject to Change without notice loca yoRK® Job: Tigard Apts. Company: Johnson barrow Oregon Project: Sales Person: Luis Ortiz SVC Quantity: 4 Roof Mounted Spun Aluminum Gravity Ventilator (Curb Base) Special: None Product Image SVC - - Spun Aluminum Gravity Rooftop exhaust(relief)or supply (fresh air)ventilator shall be Weather Cap WCC(curb i callin Constructed of a heavy-gauge spun aluminum dome,aluminum i �. base and airshaft,and galvanized internal bracing. Dome s Airshaft overlaps base venturi and is sealed to prevent water entry. Dome fasteners are sealed and dome is easily t_ ,_ ,,,,_ removable s I _ A .. E A B C E sqr F H L Damper sqr Ship Volume 9 1.5 5.5 18.5 4 11 18.5 11.25 4 Weight Throat Area Throat Vel Pressure Drop HoodVelocity 8 0.4418 1131.8 0.129 389.9 Options or Accessories Listing Unit Size 08 Curb Parent 0-Not an accessory Application S-Supply Special Option 0-None Damper Type MD1 -115 V Schedule ID Quantity Tag CFM Static Pressure Roof Pitch Dim by 12 2 4 ERV-SF 500 0.2 0 Page 1 of 1 - Edge Version 2014.0.420 - Product Information is Subject to Change without notice s Lis Ili yo R K Job: Tigard Apts. Company: Johnson barrow Oregon Project: Sales Person: Luis Ortiz Motorized 115V (MD1 ) Quantity: 4 Motor Operated Back Draft Damper Special: None Product Image Motorized 115V(MD1) •L10V damper actuator for positive opening and closing. approx. ,_ •Square galvanized steel frame, •Multi-leaf,roll formed aluminum blades;with { •Nylon bearings; and p •Eelt Edges for quiet operation , . I t Options or Accessories Listing Model Parent 0-Not an accessory Duty L-Light Application S-Supply Schedule ID Quantity Tag 1 4 ERV-SF Page 1 of 1 - Edge Version 2014.0.420 - Product Information is Subject to Change without notice OREGONSubmittal Electrical Notes and Wiring Diagrams 735 SW 20th Place 230 , Portland , OR 97205 PHONE (971) 717-7123 +a MiniCore Ventilator Engineering Guide v1.0! yo R K Li Wiring Diagrams MCV (5n0/1c100)z ) KjW14.10.Myr/ VAirl CpreVNCV50100PYT W 111pio 19997 PM REV DESCRIPTION DATE APPR'D FIELD SWITCH CONNECTION , CLAUS CACI? O NRINNNEVEMEM EVN/ME INK TB38I$peeeoa-YIL 50 I EL-60 PU-50 1 [ BL-41 PU-60 CONTROLBOX EL-1 51 S IO BL-401 7 NOTE I Door Switch I 1 Selectable depending on unit voltage. EE hEITEQ I 127 Orli BL-25,WT-25,BL-30,11T-30 for 0-1OV 24W Signal Control. Wire BL-25 to K163-4,BL-3D to K164-4, 2°811 C D far Lar Speed 24VI Wire WT-25 to K163-4, WT-30 to K164-4, I I20 SEC t I for High Speed I\ I COM A YL-1 I I I , . J151 P151 '] EL-2s Si YLw MAIL ffi,k 22 B26 6 LI -1 f PU-61 3 ERN `' EXHAUST I � I} I YL-25 { 1—BLU I /�K153 I BK-101 6 OLE LEL-2 n RD-701 7 RED GR-101 9 GRN/TEL I YL-2 I J148 P140 BL-3 I cIMAL! BL-30 1 YLW B27 Li 0 m 5JH-3D 1 2 YMT u_ �s HIGH VOL ERGE-115/230V _toy ��" 1 1-i—YL-30 { ERN INTAKE DEC �� �'K164 I BK-10B 6 BLK T LI Ti.- I Ti T2 SBL-4— Y I 12D-102 7 RED — _ GR-102 9 GRN/DEL L3 073- E YL-3 INSULATION NOTES APPR'D BY. el 02 13 0 YL-4 i INSOLRTION NOT REDOIIIED ROOFTOP MGL -- - round Lug UNLESS OTFfRWISE SPEICIFIED. SYSTEMS INC DATE STANDARD TCLERANCES Igg Dip1,mxk Dr,Grragfn�TX 70007 10!9/2017 - -- -- DRAWING TOLERANCES ARE 3 DECIMAL plw(71'£IR4_121.7 Pex(772)84B-0740 SCALE */_.010'IF NOT SPECIFIED. MTS BL-300 THICKNESS OF MATERAIL IS BILL CUSTOMER ROE TOLERANCES RD-300 SHEET METAL FLAT CUT SIDE+/-.0312 DIR.NAME.MiniCore GR-300 SHEET METAL BRAKE ANGLES+/-2 DRAWING FELE,MCV5D0K-1000XE,DWG IEGREES. UNIT ND MCV500XE/MCV1000XE NAT'L TO MEET CUSTOMEE! DESCRIPTIONS Wiring g DIC rCM PFCIFICATIIRIS, Figure 7.MCV 500/1000 Wiring Diagram **Typical actual diagram will be provided with the unit** ryREGON Submittal Unit Written Specification 735 SW 20th Place 230 , Portland , OR 97205 PHONE (971) 717-7123 SUGGESTED SPECIFICATION Furnish and install,at locations shown on plans or in accordance with schedules,mechanical cooling system complete with an Energy Recovery Ventilator(ERV).The Energy Recovery Ventilator will contain an energy recovery component rated in accordance with AHRI Standard 1060-2014 with ratings certified by AHRI.ERV shall have movable duct flanges for OA and RA intake.All other airstreams shall be horizontal as standard.Cabinet shall be galvanized steel construction with a powder coat paint finish electrostatically bonded to the metal.Where conditioned air is handled,cabinet panels shall be fully insulated to prevent sweating and minimize sound.Knockouts shall be provided for power connections.Hanging or pad mount installation capability shall be standard.Test ports shall be provided so airflow can be measured across MCV1000 the energy recovery core.Intake and exhaust air blowers of the ERV shall contain a centrifugal forward curved blower.They shall have ball bearings with direct drive motors. '° The energy recovery device shall be a static core heat exchanger per • I x1c Y AHRI Standard 1060 description.The device will be a core coated with a R4ted polymer membrane by a patented process without the use of binders or r " - adhesives which may plug the desiccant aperture.The substrate shall be a lightweight polymer.Desiccant shall not dissolve or deliquesce in the presence of water or high humidity.The core shall be easily cleanableOf with standard cleaning solution or mild soap and water solution.The p; core shall have a crossover exhaust air transfer ratio<0.5%and should accommodate a low pressure drop of 0.35 in w.g @ 100%Rated CFM. °' The air transfer shall happen without virus transfer and should be compliant with ASTM F-1671 for zero penetration.The Core itself will be built sturdy using an aluminum frame and also shall be mold and bacteria resistant(ISO 846—Rating 0). * CORE operating performance @ 100%Rated CFM • rya , INTRODUCTION Introduction: Air Exhaust or Intake . L°'' --- - The SV-Series is constructed with a weather resistant aluminum base, air shaft and cap and are .. „._L.:7'1'7-w] used as pressure relief ventilators, discharge caps t _ _ � , _ , _ c w at the end of duct work, or outside air inlet hoods. H + H = ._ Their aerodynamic design and large diameter caps F F minimize pressure drops and air noise. With these t --�A " units, it is possible to provide a weather cap that is _ E5. visually compatible with spun aluminum centrifugal or axial roof fans. -E�� SV-Series Flat(SVF) SV-Series Curb(SVC) Two styles of SV-Series are provided: • SVF (Flat) has an extra wide, flat base for A . 8 ft C • t. •Datliper installation under shingles.Available in sizes 06 �t -20;these models do not require curbs. " `" SVF06 7 3 1/2 16 7/8 8 11 1/2 12 - • SVC (Curb) has a lipped curb cap(base)found sVF08 9 - 5 1/2 21 1/4 8 131/2 181/2 - on virtually all roof top ventilators. Available in SVF10 11 - 51/2 21 1/4 10 151/2 21 - all sizes,these models require a roof curb which sVFI2 13 7 24 10 17 25 - must be ordered separately (or provided by the SVF14 15 - 7 28 10 17 28 - field.) SVF16 17 - 10 28 12 22 30 - SVF18 19 - 10 32 12 22 32 - Both styles are weather tight, include bird screen SVF20 21 - 101/2 32 12 221/2 37 - and utilize heavy gauge galvanized hood brackets SVC06 7 1 3 1/2 15 4 81/2 12 8 3/4 to provide a rigid, long lasting unit. The caps are L:svcos° .: ..9 ) 11/2 R' z=,I:i; i ,3 4 :,11 ,'`- 181/2 .i 111/4 seamless, spun aluminum which can be removed svcio 11 11/2 51/2 181/2 4 11 21 111/4 for access to the air shaft when required. SVC12 13 2 7 20 1/2 4 13 25 15 3/4 SVC14 15 2 7 24 3/4 4 13 28 15 3/4 NOTES: All dimensions are in inches. The recommended SVC16 17 2 10 24 3/4 4 1/2 16 1/2 30 15 3/4 clearances for the roof openings for installing the dampers provided is 1/4"(sizes 06-20)and 1/2"(sizes 24-48).Installation SVC18 19 2 10 28 1/2 4 1/2 16 1/2 32 19 3/4 of motorized dampers requires 12" high curbs. Installing roof SVC20 21 2 10 1/2 28 1/2 5 1/2 18 37 19 3/4 dampers is not recommended for SVF models.SVF roof openings SVC24 25 2 11 33 1/2 5 1/2 18 1/2 45 24 3/4 normally match throat diameters. If round duct is used for either SVC30 31 2 11 36 1/2 7 20 52 27 3/4 the SVF or SVC units, actuated round dampers, should be specified. SVC36 37 2 15 441/2 7 24 65 351/2 SVC42 43 2 16 521/2 7 25 67 431/2 SVC48 49 2 16 59 7 25 72 491/2 Pressure Drop Fresh Air Intake The performances of these models are pr=- - - -. Throat r a t Drop, NOT Static Pressure, which is normally shown. The air flow (CFM) int. shown includes the Total Pressure Drop through the weather cap. Total Pressure Drop includes both Static and Velocity Pressure drops. svF/svcos 0.3 0.5 250 SVF/SVC08 0.4 1.4 700 To calculate the Static Pressure, perform the following steps: svF/svc10 0.7 1.7 850 SVF/SVC12 0.9 2.5 1,250 1. Throat Velocity=CFM_Throat Area SVF SVC14 1.2 3.0 1,500 CFM is design requirement.Throat area is in units of square feet SVF/SVC16 1.6 3.3 1,650 (shown in Fresh Air Intake chart to the right.) SVF/SVC18 2.0 3.6 1,800 2. Velocity Pressure=(Throat Velocity T 4002)2 SVF/SVC20 2.4 5.1 2,550 Throat velocity is from step#1. SVC24 3.4 7.6 3,800 3. Static Pressure=Total Pressure-Velocity Pressure svcso 5.2 9.5 4,750 Total Pressure is Pressure Drop shown on performance charts. svc36 7.5 15.6 7,800 SVC42 10.1 14.4 7,200 Velocity Pressure is from step#2. SVC48 13.1 15.2 7,600 Recommended maximum air intake capacities to minimize the possibility of water entry are listed above. 'Based on hood entrance velocity. 2 YORK® PRESSURE RELIEF VENTILATORS, SV-SERIES PERFORMANCE DATA EXHAUST•CFM Pressure Drop("WC) Model . . 0.025 0.050 0.100 0.125 0.150 0.200 0.250 0.300 0.350 SVF/SVC06 93 131 185 207 227 262 293 320 346 221 313 I 442 I 494 i 541 -625 — - - 699 766 : 827 SVF/SVC10 297 420 594 664 727 840 939 1029 1111 SVF/SVC12 493 697 986 1102 1208 1394 1559 1708 1845 SVF/SVC14 604 853 1207 1349 1478 1707 1908 2091 2258 SVF/SVC16 746 1055 1492 1668 1827 2110 2359 2584 2791 SVF/SVC18 919 1300 1838 2055 2251 2599 2906 3184 3439 SVF/SVC20 1127 1593 2253 2519 2759 3186 3562 3902 4215 SVC24 1471 2080 2941 3288 3602 4159 4650 5094 5502 SVC30 1768 2500 3535 3952 4329 4999 5589 6123 6613 SVC36 2730 3860 5459 6103 6686 7720 8631 9455 10213 SVC42 3468 4904 6936 7755 8495 9809 10967 12014 12976 _. ... SVC48 5363 7584 10725 11991 13135 15167 16958 ' 18576 20065 INTAKE-CFM Pressure Drop("WC) -1 0.100 0425 0.150 : 040 i 0.250 0.300 0.350 SVF/SVC06 64 91 128 143 157 181 202 222 239 I SVF/SVC08 148 209 1 296 331 : 363 419 468 513 SVF/SVC10 202 286 404 452 495 571 639 700 756 SVF/SVC 1 2 330.5 467 661 739 810 935 1045 1145 1237 SVF/SVC14 440.5 623 881 985 1079 1246 1393 1526 1648 SVFISVC 16 552 781 1104 1234 1352 1561 1746 1912 2065 SVF/SVC18 707.5 1001 1415 1582 1733 2001 2237 2451 2647 SVF/SVC20 856 1211 1712 1914 2097 2421 2707 2965 3203 SVC24 1191 1684 2382 2663 2917 3369 3766 4126 4456 SVC30 1537.5 2174 3075 3438 3766 4349 4862 5326 5753 SVC36 2402 3397 4804 5371 5884 6794 7596 8321 8987 SVC42 3052 4316 6104 6824 7476 8632 9651 10572 11420 SVC48 4612 6522 9224 10313 11297 13045 14584 15976 17257 ENGINEERING SPECIFICATIONS Model Color Roof Curb Wooden Nailer SVF =SV Series Flat IT *').!1....'is,:r See selection software. ri14-t4,00.0,,,F.A1 10,.0...,,#.'s Y Yf:4!:t;;if 4-1, 50=Chrome Green W= Wooden Nailer 55=Pale Green Damper Unit Size 56=Dove Gray 0 = None , Curb Paint/Coating 06, 08, 10, 12, 14, 16, 18, 20, 61=White 7.4!lit74-,:,t,1,4;l7-11-',,, on,. _,N4A 0 =None 24,30,36,42,48 63=Oxford Beige i.:ti-r---'i.:PL ' l ,ryB =Air Dried Epoxy 65=Dover White Q=Enamel Application EIS 66=Desert Tan MPBD2=Motor Operated 230V E =Exhaust 70=Black MPBD4=Motor Operated 450V Screen S =Supply 73=Smoke Gray 0=None 77=Brick Red Metal Liner k4.-1'1:'''''Y::;Aii..; :il. : 79=Peppercorn Paint/Coating 0 =None 81=Pale BrownfLUZtL =Liner F =Epoxy Powder Coat* 83=Chocolate Brown G=Epoxy Powder Coat w/UV* 85=Timeless Bronze Damperl H=Hi-Temp Powder Coat* 94=Charcoal Holding Plate- . -.' J =Non-stick Powder Coat* X =Special P=Damper Holding Plate K=Phenolic Powder Coat* L =Phenolic Powder Coat w/UV* Roof Slo.e Neoprene Gasket N=Polyester Powder Coattli;i-Zraill 0 =None X=Special S=Single Slope G=Gasket *Not available with choice of D=Double Slope color. 3 110 Submittal Warranty 735 SW 20th Place 230 , Portland , OR 97205 PHONE (971) 717-7123 • Standard Terms and Conditions—U.SA. References to"products","equipment"or"services"herein shall mean those to be furnished by Seller as identified on the applicable Seller Quotation (b)any copyright,trademark,trade secret or other proprietary right of a third party which is enforceable in (1)AGREEMENT AND LIMITATIONS. Buyer accepts these Standard Terms and Conditions by signing the United States, as a result of Buyer's use of the product or equipment within the United States, and returning Seller's Quotation,by sending a purchase order in response to the Quotation,or Buyer's provided that:(i)Buyer gives Seller prompt written notice of any such Claim,(ii)Buyer gives Seller full instructions to Seller to begin work, including shipment of product or performance of services. Upon authority to defend or settle any such Claim,and(iii)Buyer gives Seller proper and full information and Buyer's acceptance,Seller's Quotation and the related terms and conditions referred to in the Quotation, assistance,at Seller's expense(except for Buyer's employees'time)to defend or settle any such Claim. together with the Distributor Sales Agreement between Buyer and Seller, shall constitute the entire THE FOREGOING IS IN LIEU OF ANY WARRANTIES OF NONINFRINGEMENT, WHICH ARE agreement relating to the products,equipment and services covered by the Quotation(the"Agreement"). HEREBY DISCLAIMED. The foregoing obligation of Seller does not apply with respect to products or No terms,conditions or warranties other than those identified in the Quotation and no agreement or equipment or portions or components thereof(a)not supplied by Seller,(b)made in whole or in part in understanding, oral or written, in any way purporting to modify such terms and conditions whether accordance with Buyer or owner specifications,(c)which are modified after shipment by Seller, if the contained in Buyer's purchase order or shipping release forms,or elsewhere,shall be binding on Seller alleged infringement related to such modification, (d) combined with other products, processes or unless hereafter made in writing and signed by Seller's authorized representative. Buyer is hereby notified materials where the alleged infringement relates to such combination,(e)where Buyer continues allegedly of Sellers express rejection of any terms inconsistent with these Standard Terms and Conditions or to any infringing activity after being notified thereof and/or after being informed of modifications that would have other terms proposed by Buyer in accepting Sellers Quotation. Neither Seller's subsequent lack of avoided the alleged infringement without significant loss of performance or functionality, or(f)where objection to any such terms,nor the delivery of the products or services,shall constitute an agreement by Buyers use of the product or equipment is incident to an infringement not resulting primarily from the Seller to any such terms. product or equipment;Buyer will indemnify Seller and its officers,directors,agents,and employees from (2)TERMINATION OR MODIFICATION. If either party materially breaches this Agreement,the other patty all damages, settlements, attorneys' fees and expenses related to a claim of infringement, may notify the breaching party in writing,setting out the breach,and the breaching party will have 60 days misappropriation,defamation,violation of rights of publicity or privacy excluded from Sellers indemnity following such notice to remedy the breach.If the breaching party fails to remedy the breach during that obligation herein. period, the other party may by written notice terminate the Agreement. These Standard Terms and Conditions may be modified or rescinded for accepted orders only by a writing signed by authorized (9)GOVERNING LAW.The formation and performance of the Agreement shall be governed by the laws of the State of Wisconsin,U representatives of both Seller and Buyer. Accepted orders may by cancelled or modified by Buyer only commenced action for breach of the Agreement or any covenant or warranty must be with Sellers express written consent.If cancellation or modification is allowed,Buyer agrees to pay to commenced within one year after the cause of action has accrued unless such provision is not permitted by Seller all expenses incurred and damage sustained by Seller on account of such cancellation or applicable law. modification,plus a reasonable profit. (10)DISPUTE RESOLUTION. Seller shall have the sole and exclusive right to determine whether any (3)PRICE,SHIPMENT,AND PAYMENT. Prices on accepted orders are firm for a period of 90 days from dispute,controversy or claim arising out of or relating to the Agreement,or the breach thereof,shall be date of acceptance.Price and delivery is F.O.B.point of manufacture,unless otherwise provided. Unless submitted to a court of law or arbitrated. The venue for any such arbitration shall be in Milwaukee, otherwise agreed to in writing by Seller,all payments are due net thirty(30)days from the date of invoice. Wisconsin. The arbitrators award may be confined and reduced to judgment in any court of competent Seller may,at its sole option,have the right to make any delivery under this Agreement payable on a cash jurisdiction. In the event the matter is submitted to a court,Seller and Buyer hereby agree to waive their or payment guarantee before-shipment basis. In the case of export sales,unless otherwise agreed to in right to trial by jury and covenant that neither of them will request trial by jury in any such litigation. writing by Seller,all payments are to be made by means of a confirmed irrevocable letter of credit. (11)SOFTWARE LICENSE.To the extent software is provided by Seller under the Agreement,Buyer (4)TAXES.All prices exclude state and tical use,sales or similar taxes. Such taxes,if applicable,will appear agrees that such software may only be used in accordance with the terms and conditions of the software as separate items on the invoice unless Buyer provides a tax exemption certificate that is acceptable to taxing license agreement that accompanies the software. Buyer agrees not to directly or indirectly decompile, authorities. disassemble,reverse engineer or otherwise derive the source code for the software.If Buyer is a U.S. Government agency, Buyer acknowledges that the software licensed under the Agreement is a (5) DELIVERY. The delivery date(s)provided by Seller for the product and equipment is only an estimate commercial item that has been developed at private expense and not under a Government contract.The and is based upon prompt receipt of all necessary information from Buyer.The delivery date(s)is subject Government's rights relating to the software are limited to those rights applicable to Buyers as set forth to and shall be extended by delays caused by strikes,fires,accidents,shortages of labor or materials, herein and is binding on Government users in accordance with Federal Acquisition Regulation 48 C.F.R. embargoes,or delays in transportation,compliance with government agency or official requests,or any Section 12.212 for non-defense agencies and/or Defense FAR Supplement 48 C.F.R.Section 227.7202-1 other similar or dissimilar cause beyond the reasonable control of Seller.FAILURE TO DELIVER WITHIN for defense agencies. THE TIME ESTIMATED SHALL NOT BE A MATERIAL BREACH OF CONTRACT ON SELLER'S PART. If Buyer causes Seller to delay shipment or completion of the product or equipment,Seller shall be entitled (12)MISCELLEANEOUS to any and all extra cost and expenses resulting from such delay. (a)CHANGES OF CONSTRUCTION AND DESIGN:Seller reserves the right to change or (6)LIMITED WARRANTY. Seller warrants that the product and equipment furnished by Seller under revise the construction and design of the products or equipment purchased by Buyer,without liability or the Agreement will be of good quality and that the services provided by Seller will be provided in a obligation to incorporate such changes to products or equipment ordered by Buyer unless specifically good and workmanlike manner. If Seller installs or furnishes product or equipment under the agreed upon in writing reasonably in advance of the delivery date for such products or equipment. Buyer Agreement, and such product or equipment, or any part thereof, is covered by a manufacturers agrees to bear the expense of meeting any changes or modifications in local code requirements which warranty, Seller will transfer the benefits of that manufacturer's warranty to Buyer. This limited become effective after Seller has accepted Buyers order. warranty does not cover failures caused in whole or in part by(i)improper installation or maintenance performed by anyone other than Seller; (ii) improper use or application; (iii)corrosion; (iv) normal (b) CHARACTER OF PRODUCT AND SECURITY INTEREST:The goods delivered by deterioration;(v)operation beyond rated capacity,(vi)the use of replacement parts or lubricants which Seller under the terms of the Agreement shall remain personal property and retain its character as such no do not meet or exceed Sellers specifications,or(vii)if Sellers serial numbers or warranty date decals matter in what manner affixed or attached to any structure or property.Buyer grants Seller a security have been removed or altered. To qualify for warranty consideration for products or equipment,at the interest in said goods,any replacement parts and any proceeds thereof until all sums due Seller have been paid to it in cash.This security interest shall secure all indebtedness or obligations of whatsoever earlier of the Buyers discovery of the defect or the time at which the Buyer should have discovered the defect; Buyer must immediately notify Seller in writing for instructions on warranty procedures. nature now or hereafter owing Buyer to Seller.Buyer shall pay all expenses of any nature whatsoever Seller's sole obligation for defective services shall be to repair or to replace defective parts or to incurred by Seller in connection with said security interest. properly redo defective services. All replaced equipment becomes Sellers property. THIS (c)INSURANCE:Buyer agrees to insure the goods delivered under the Agreement in an WARRANTY IS EXCLUSIVE AND IS PROVIDED IN LIEU OF ALL OTHER EXPRESS OR IMPLIED amount at least equal to the purchase price against loss or damage from fire,wind,water or other causes. WARRANTIES INCLUDING,WITHOUT LIMITATION,ANY WARRANTY OF MERCHANTABILITY The insurance policies are to be made payable to Seller and Buyer in accordance with their respective OR FITNESS FOR A PARTICULAR PURPOSE,WHICH ARE HEREBY DISCLAIMED. interests,and when issued are to be delivered to Seller and held by it. Failure to take out and maintain such insurance shall entitle Seller to declare the entire purchase price to be immediately due and payable (7)INDEMNIFICATION,REMEDIES AND LIMITATIONS OF LIABILITY. In addition to Paragraph 8 below and shall also entitle Seller to recover possession of said goods. regarding patents,Buyer agrees that Seller shall be responsible only for such injury, loss,or damage caused by the intentional misconduct or the negligent act or omission of Seller. In the event Buyer daims (d)INSTALLATION: If installation by the Seller is included within the Seller's Quotation, Seller has breached any of its obligations,whether of warranty or otherwise,Seller may request the return of Buyer shall provide all of the following at its own expense and at all times pertinent to the installation:i) the goods and tender to Buyer the purchase price theretofore paid by Buyer,and in such event,Seller shall free,dry,and reasonable access to Buyers premises;and ii)proper foundations,lighting,power,water have no further obligation under the Agreement except to refund such purchase price upon redelivery of the and storage facilities reasonably required. goods. If Seller so requests the return of the goods,the goods shall be redelivered to Seller in accordance with Seller's instructions and at Seller's expense.The remedies contained in these Standard Terms and (e)COMPLIANCE WITH LAWS: Sellers obligations are subject to the export administration Conditions shall constitute the sole recourse of Buyer against Seller for breach of any of Seller's obligations and control laws and regulations of the United States. Buyer shall comply fully with such laws and regulation under the Agreement,whether of warranty or otherwise. IN NO EVENT SHALL SELLER BE LIABLE FOR in the export,resale or disposition of purchased products or equipment. Quotations or proposals made,and SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING LOSS OF any orders accepted by Seller from a Buyer outside the United States are with the understanding that the ANTICIPATED PROFIT,OR OTHER ECONOMIC LOSS,OR FOR ANY DAMAGES ARISING IN TORT, ultimate destination of the products or equipment is the country indicated therein. Diversion of the products or WHETHER BY REASON OF STRICT LIABILITY,NEGLIGENCE,OR OTHERWISE,REGARDLESS OF equipment to any other destination contrary to the United States is prohibited.Accordingly,if the foregoing WHETHER SELLER HAS BEEN APPRISED OF THE POSSIBILITY OF SUCH. understanding is incorrect,or if Buyer intends to divert the products or equipment to any other destination, Buyer shall immediately inform Seller of the correct ultimate destination. (8)PATENTS.Seller shall indemnify,defend,or at its option settle,and hold Buyer and its directors, officers, employees,agents,subsidiaries,affiliates,subcontractors and assignees, harmless from and against any and all claims,suits,actions or proceeds("Claims")against such parties based upon the infringement or alleged infringement,or violation or alleged violation,of(a)any United States patent and Energy Recovery Ventilator(ERV) Limited Warranty a) Unless otherwise set forth in the Sales Confirmation, Seller warrants to Buyer,for a period of twelve(12)months following the date of delivery to the Delivery Location(the "Warranty Period"),that the Goods will be free from defects in material and workmanship. Notwithstanding the foregoing,the Warranty Period for consumable Goods shall in no event exceed recommended replacement intervals set forth in the Instructions (hereinafter defined). If, prior to the expiration of the Warranty Period, Buyer informs Seller in writing of any breach of this limited warranty,then Seller may repair or replace the Goods that gave rise to such breach or,in Seller's sole and exclusive discretion, refund the amounts that Buyer paid for such Goods. b) The foregoing limited warranties do not apply to(i)any defect in Goods not manufactured by Seller;and(ii)any Goods manufactured according to Buyer's specifications. c) Buyer shall bear the costs of access,de-installation,re-installation and transportation of the Goods to Seller and back to Buyer.Any repair or replacement pursuant to this limited warranty shall not extend the Warranty Period.Seller does not warrant the Goods,or any repaired or replacement parts,against normal wear and tear.This limited warranty and remedy are expressly conditioned upon:(i)Buyer's payment of the purchase price in full, (ii)Buyer giving written notice of the defect,reasonably described,to Seller within ten (10)days of the time when Buyer discovers or ought to have discovered the defect,(iii) the storage,installation,operation,use,and maintenance of the Goods in compliance with the published specifications and instructions provided by Seller or its suppliers or subcontractors (the "Instructions"), (iv) the existence of proper records of Buyer's operation and maintenance of the Goods during the Warranty Period,(v)Buyer providing Seller with a reasonable opportunity to examine the Goods and the aforementioned records,and(vi)the absence of any unauthorized modification or repair of the Goods. d) Before any test may be used to evaluate the Goods,Buyer shall:(i)provide Seller with reasonable written notification of such test,(ii)allow Seller to be present during such test, and(iii)receive Seller's consent to the conditions of such test,which consent will not be unreasonably withheld.If a test is performed on the Goods,and Seller has not consented to the conditions of such test,then this limited warranty shall be void. e) THE REMEDIES SET FORTH IN THIS SECTION 8 ARE BUYER'S SOLE AND EXCLUSIVE REMEDIES FOR ANY FAILURE OF SELLER TO COMPLY WITH ITS OBLIGATIONS UNDER THIS AGREEMENT, INCLUDING ANY BREACH OF THE LIMITED WARRANTY SET FORTH IN THIS SECTION 8.Correcting any defect in the manner set forth in this Section 8 shall constitute complete fulfillment of Seller's obligations and liabilities under the Agreement following the delivery of the Goods, regardless of whether a claim is based in contract law,tort law(including negligence, strict liability or otherwise), or other legal theory. THE LIMITED WARRANTY SET FORTH IN THIS SECTION 8 IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES,WHETHER STATUTORY,EXPRESS,OR IMPLIED.EXCEPT AS SET FORTH IN THIS SECTION 8, SELLER MAKES NO EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO ANY WARRANTIES OF MERCHANTABILITY, NON-INFRINGEMENT, OR FITNESS FOR A PARTICULAR PURPOSE, OR ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.Any other oral or written statements,whether contained in general advertising or other printed material,do not constitute warranties,and Buyer agrees that it is not entering into the Agreement in reliance upon any such statements.