Report (98) r t \--A-o c COMcheck Software Version 4.0.6.0 ad Interior Lighting compliance Certificate RECEIVED Project Information MAY 2 2201 Energy Code: 90.1 (2010)Standard Project Title: Cycle Bar CITY OF TIGARD Project Type: Alteration BUILDING DIVISION Construction Site: Owner/A.: ,1FC1 PR Ores Designer/Contractor: 12284 SW,Scholls Ferry Road ,-`\ ' NCCINCE- s!0 Peter A. Leptuch,P.E. SUTigard,lTE OR 97223 / `ry 4; 9 '- 1236 Golden Eagle Court 5 gp { Aubrey,TX 76227 (940)735-5127 iriifr Air • t pleptuch@yahoo.com t `-'„ OREGON ciN oZ" Allowed Interior Lighting Power ,c4���1Ry A0 2 .tJ AgOAM �-� B C D Area Category f Floor Area Allowed Allowed Watts EXPIRES /4/3/A9' (ft2) Watts 1 ft2 (B X C) 1-Cycle Studio(Gymnasium/Fitness Center:Fitness Area) 3459 0.72 2490 Total Allowed Watts= 2490 Proposed Interior Lighting Power A B C D E Fixture ID:Description/Lamp/Wattage Per Lamp 1 Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Cycle Studio(Gymnasium/Exercise Center:Exercise Area 3459 sq.ft.) Compact Fluor 1:PEN:Pendant:Twin Tube 13W:Electronic: 3 3 39 117 Compact Fluor 2:D:Downlight:Triple 4-pin 32W:Electronic: 1 48 32 1536 Compact Fluor 3:D2:Downlight w/Damper:Triple 4-pin 32W:Electronic: 1 4 32 128 Linear Fluor 1:ST:Strip Light:24"T8U 32W:Electronic: 2 4 64 256 Linear Fluorescent 3:BW:Brand Wall Lighting:48"T8 25W(Super T8):Electronic: 1 10 25 Exempt Exemption:Advertising/Directional Signage Total Proposed Watts= 2037 Interior Lighting PASSES Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed interior lighting I systems have been designed to meet the 90.1 (2010)Standard requirements in COMch , rsion 4.0.6.0 and to comply with any aappl able mandatory re uiremen listed in the Inspection Che •. , 6. 4-,:r .0 .,---.. .. .,,J ciri, Name-Title /-'....__ _C-r a#C2,. { Signature Date �'' Project Title: Cycle Bar Report date: 05/17/17 Data filename: C:\Users\Mike Palmer\Dropbox\_(P-2017)\_17.007 GHA-CB-Tigard,OR\_17.007 GHA-CB- Page 1 of 12 Tigard, OR-2014 Oregon Comcheck(UNTOUCHED).cck COMcheck Software Version 4.0.6.0 5 Mechanical Compliance Certificate Project Information Energy Code: 90.1 (2010)Standard Project Title: Cycle Bar Location: Tigard,Oregon Climate Zone: 4c Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: 12284 SW.Scholls Ferry Road Peter A. Leptuch,P.E. SUITE A 1236 Golden Eagle Court Tigard,OR 97223 Aubrey,TX 76227 (940)735-5127 pleptuch@yahoo.com Mechanical Systems List Quantity System Type&Description - 2 RTU-2,3(7.5 TON) Heating:1 each-Central Furnace,Gas,Capacity=180 kBtuth Proposed Efficiency=81.00%Et,Required Efficiency=80.00%Et Cooling:1 each-Single Package DX Unit,Capacity=83 kBtu/h,Air-Cooled Condenser,Air Economizer Proposed Efficiency=11.10 EER,Required Efficiency: 11.00 EER Fan System: None SYSTEM COMPLIANCE REQUIRED. 1 RTU-1 (5.0 TON) Cooling: 1 each-Single Package DX Unit,Capacity=59 kBtu/h,Air-Cooled Condenser,Air Eco ' 'ii510) PR°P Proposed Efficiency=14.10 SEER,Required Efficiency: 13.00 SEER \.' NGINC 6'6> Fan System: None t`'+ '� �9 0 SYSTEM COMPLIANCE REQUIRED. t, �p f 1 I Water Heater(GAS) t I _-,�,,. r.� yi f- Gas Storage Water Heater,Capacity:98 gallons,Input Rating:76 Btu/h w/Circulation Pumk-0, q OREGON Y Proposed Efficiency:80.00%Et,Required Efficiency:80.00%Et ,), /1"e/ RY 10 PJC) SWH COMPLIANCE REQUIRED. 1OA M 1-C' • EXPIRES. i 3 Mechanical Compliance Statement A Compliance Statement: The proposed mechanical alteration project represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed mechanical systems have been designed to meet the 90.1 (2010)Standard requirements in COMch k ersi 4.0. .0 a d to comply with any applicable at / . mandry requirements II ted in e Ins ection Checklist. or/17/19_ ep Name-TMe ` Signature Date Project Title: Cycle Bar Report date: 05/17/17 Data filename: C:\Users\Mike Palmer\Dropbox\ (P-2017)\_17.007 GHA-CB-Tigard,OR\_17.007 GHA-CB- Page 2 of 12 ` Tigard,OR-2014 Oregon Comcheck(UNTOUCHED).cck COMcheck Software Version 4.0.6.0 Inspection Checklist Energy Code: 90.1 (2010) Standard Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed: Where compliance is itemized in a separate table, a reference to that table is provided. Section Plan Review Complies? Comments/Assumptions & Req.ID' 4,2.2,6.4. Plans, specifications, and/or ❑Complies 14.2.1,6.7. calculations provide all Information ❑Does Not '2 with which compliance can be [PR2]1 determined for the mechanical ❑Not Observable systems and equipment and ❑Not Applicable document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. 4.2.2,7.7. Plans, specifications, and/or ❑Complies 11,10.4.2 calculations provide all information EDoes Not [PR3]i with which compliance can be determined for the service water ❑Not Observable heating systems and equipment and ❑Not Applicable document where exceptions to the standard are claimed. Hot water system sized per manufacturer's sizing guide. 4.2.2,9.4. Plans, specifications,and/or ❑Complies 4,9.7 calculations provide all information ODoes Not [PRO with which compliance can be determined for the interior lighting ['Not Observable and electrical systems and equipment ❑Not Applicable and document where exceptions to the standard are claimed.Information provided should include interior lighting power calculations,wattage of bulbs and ballasts, transformers and control devices. !6.7.2.4 Detailed instructions for HVAC ❑Complies 3[PR5]1 systems commissioning Included on ❑Does Not the plans or specifications for projects ❑Not Observable >=50,000 ft2, ❑Not Applicable Additional Comments/Assumptions: 1'High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Cycle Bar Report date: 05/17/17 Data filename: C:\Users\Mike Palmer\Dropbox\(P-2017)\_17.007 GHA-CB-Tigard,OR\_17.007 GHA-CB- Page 3 of 12 Tigard,OR-2014 Oregon Comcheck(UNTOUCHED).cck Section # Footing/Foundation Inspection Complies? Comments/Assumptions & Req.ID 6.4.3.8 Freeze protection and snow/ice ❑Complies [FO9I3 melting system sensors for future ❑Does Not connection to controls. ONot Observable ONot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Cycle Bar Report date: 05/17/17 Data filename: C:\Users\Mike Palmer\Dropbox\_(P-2017)\_17.007 GHA-CB-Tigard,OR\_17.007 GHA-CB- Page 4 of 12 Tigard,OR-2014 Oregon Comcheck(UNTOUCHED).cck Section # Plumbing Rough-In inspection Complies? Comments/Assumptions &Req.1D '7.4,4.1 Temperature controls installed on ❑Complies EPL2j3 service water heating systems ODoes Not (<=12OsF to maximum temperature -- for intended use). LJNot Observable ❑Not Applicable 7.4,4.2 Automatic time switches installed to ❑Complies [PL3ji automatically switch off the ❑Does Not recirculating hot-water system or heat ❑Not Observable trace. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Cycle Bar Report date: 05/17/17 Data filename: C:\Users\Mike Palmer\Dropbox\_(P-2017)\_17.007 GHA-CB-Tigard,OR\_17.007 GHA-CB- Page 5 of 12 Tigard,OR-2014 Oregon Comcheck(UNTOUCHED).cck :: ° ..Mechanical Rough-In Plans Verified Field VerifiedCompliesComments/Assumptions eq.ID 16.4.1.4,6. HVAC equipment efficiency Efficiency:_ Efficiency: OComplies See the Mechanical Systems list 14.15 verified. Non-NAECA HVAC ❑Does Not for values. [ME1]2 equipment labeled as meeting 90.1. ❑Not Observable ONot Applicable :6.4.3.4.1 Stair and elevator shaft vents OComplies 1[ME3]3 have motorized dampers that ❑Does Not automatically close. ONot Observable ONot Applicable ;6.4.3.4.2, Outdoor air and exhaust systems DComplies ;6.4.3.4.3 have motorized dampers that ❑Does Not (ME4]3 automatically shut when not in use and meet maximum leakage Not Observable rates.Check gravity dampers ❑Not Applicable where allowed. 16.4.3.4.5 Enclosed parking garage DComplies 1[ME39]3 ventilation has automatic ❑Does Not 1 contaminant detection and j capacity to stage or modulate ❑Not Observable fans to 50%or less of design ONot Applicable i capacity. 16.4.3.4.4 Ventilation fans>0.75 hp have OComplies [ME5.i3 automatic controls to shut off fan ❑Does Not 1 when not required. ONot Observable ONot Applicable 6.4.3.9 Demand control ventilation ❑Complies [ME6]1 provided for spaces >500 ft2 and ODoes Not >40 people/1000 ft2 occupant density and served by systems ['Not Observable with air side economizer,auto ONot Applicable modulating outside air damper control,or design airflow>3,000 cfm. 6.4.3.10 Single zone HVAC systems with DComplies See the Mechanical Systems list `[ME40]2 fan motors>=5 hp have variable ❑Does Not for values. airflow controls.Air conditioning equipment with a cooling ONot Observable capacity>=110,000 Btu/h has ONot Applicable i variable airflow controls. 16.4.3.10 Single zone HVAC systems with DComplies See the Mechanical Systems list [ME40]2 fan motors>=5 hp have variable ❑Does Not for values. airflow controls.Air conditioning equipment with a cooling ['Not Observable capacity>=110,000 Btu/h has DNot Applicable variable airflow controls. - 6.4.4.1.1 Insulation exposed to weather DComplies 1[ME7]3 protected from damage. ❑Does Not Insulation outside of the conditioned space and associated ONot Observable i. with cooling systems is vapor ONot Applicable retardant. .6.4.4.1.2 HVAC ducts and plenums R- R-__-_ DComplies [ME8]2 insulated.Where ducts or ❑Does Not plenums are installed in or under a slab,verification may need to ONot Observable occur during Foundation ONot Applicable 1 Inspection. 16.4.4.1.3 HVAC piping insulation thickness. i in. in. DComplies i[ME9]2 Where piping is installed in or ❑Does Not under a slab,verification may need to occur during Foundation :Not Observable Inspection. ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Cycle Bar Report date: 05/17/17 Data filename: C:\Users\Mike Palmer\Dropbox\_(P-2017)\_17.007 GHA-CB-Tigard, OR\_17.007 GHA-CB- Page 6 of 12 Tigard,OR-2014 Oregon Comcheck(UNTOUCHED).cck Section Mechanical Rough-In Plans Verified Field Verified Inspection Value Value Complies? Comments/Assumptions Req.ID 6.4.4.1.4 Thermally ineffective panel ❑Complies [ME41]3 surfaces of sensible heating ❑Does Not panels have insulation >= R-3.5. ONot Observable ONot Applicable 6.4.4.2.1 Ducts and plenums sealed based ❑Complies [ME10]2 on static pressure and location. ODoes Not ❑Not Observable ONot Applicable 16.4.4.2.2 Ductwork operating >3 in.water ❑Complies [ME11]3 column requires air leakage ODoes Not testing. ONot Observable ❑Not Applicable '6.4.4.2.2 Ductwork operating >3 in. water ❑Complies [ME11]3 column requires air leakage ODoes Not testing. ONot Observable ❑Not Applicable 16.5.1,6.5. Air economizers provided where ❑Complies 11.1,6.5.1. required, meet the requirements ODoes Not 13 for design capacity,control [ME12]1 signal,ventilation controls,high- :Not Observable limit shut-off, integrated ONot Applicable economizer control,and provide a means to relieve excess outside air during operation. '6.5.1,6.5. Air economizers provided where ❑Complies 1.1,6.5.1. required, meet the requirements ODoes Not 3 for design capacity,control [ME12)1 signal,ventilation controls, high- ❑Not Observable limit shut-off,integrated ONot Applicable economizer control,and provide a means to relieve excess outside air during operation. 6.5.2.3 Dehumidification controls ❑Complies [ME19]3 provided to prevent reheating, ODoes Not recooling,mixing of hot and cold airstreams or concurrent heating ONot Observable and cooling of the same ONot Applicable airstream. 6.5.3.3 Multiple zone VAV systems with ❑Complies See the Mechanical Systems list [ME42]3 DDC of individual zone boxes ODoes Not for values. have static pressure setpoint reset controls. ONot Observable ❑Not Applicable 6.5.3.3 Multiple zone VAV systems with ❑Complies See the Mechanical Systems list [ME42]3 DDC of individual zone boxes ODoes Not for values. have static pressure setpoint reset controls. ONot Observable ONot Applicable 6.5.4.1 HVAC pumping systems>10 hp ❑Complies [ME25)3 designed for variable fluid flow. ❑Does Not ONot Observable ONot Applicable 6.5.6.1 Exhaust air energy recovery on ❑Complies [ME56]1 systems meeting Table 6.5.6.1. ODoes Not ❑Not Observable Dot Applicable 1 High Impact(Tier 1) 2 :Medium Impact(Tier 2) 3 Low Impact(Tier 3) I Project Title: Cycle Bar Report date: 05/17/17 Data filename: C:\Users\Mike Palmer\Dropbox\_(P-2017)\_17.007 GHA-CB-Tigard, OR\_17.007 GHA-CB- Page 7 of 12 Tigard,OR-2014 Oregon Comcheck(UNTOUCHED).cck Section Mechanical Rough-In Plans Verified Field Verified # Inspection Value Value Complies? Comments/Assumptions j& Req.ID , 6.5.7.1.1 Kitchen hoods>5,000 cfm have DComplies ;[ME3212 make up air>=50%of exhaust ODoes Not air volume. ❑Not Observable ❑Not Applicable 6.5.7.1.5 Approved field test used to DComplies 1[ME49]3 evaluate design air flow rates ❑Does Not and demonstrate proper capture and containment of kitchen ❑Not Observable exhaust systems. ❑Nat Applicable 16.5.7.2 Fume hoods exhaust systems DComplies [ME33]' >=15,000 cfm have VAV hood ❑Does Not exhaust and supply systems, direct make-up air or heat ❑Net Observable recovery. DNot Applicable 16.5.8.1 Unenclosed spaces that are DComplies I[ME34]2 heated use only radiant heat. ❑Does Not ❑Not Observable ❑Not Applicable 6.5.9 Hot gas bypass limited to: <=240 DComplies [ME35]' kBtu/h-50%>240 kBtu/h-25% ❑Does Not ❑Not Observable ❑Not Applicable 6.5.9 Hot gas bypass limited to: <=240 DComplies (ME35]' kBtu/h-50% >240 kBtu/h-25% ❑Does Not ❑Not Observable ONot Applicable 7.4.2 Service water heating equipment DComplies [ME3612 meets efficiency requirements. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Cycle Bar Report date: 05/17/17 Data filename: C:\Users\Mike Palmer\Dropbox\_(P-2017)\_17.007 GHA-CB-Tigard,OR\_17.007 GHA-CB- Page 8 of 12 Tigard,OR-2014 Oregon Comcheck(UNTOUCHED).cck Section • # Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID 9.4.1.1 Automatic controls to shut off all ❑Complies [EL1]2 building lighting. ❑Does Not ONot Observable ONot Applicable 19.4.1.2 Independent lighting controls installed ❑Complies [EL2]2 per approved lighting plans and all ❑Does Not 1 manual controls readily accessible and visible to occupants. ONot Observable ❑Not Applicable :9.4.1.3 Parkinggarage lighting is equipped g g q pped ❑Complies 1[EL11]2 with required lighting controls and DDoes Not daylight transition zone lighting. Pilot Observable ONot Applicable 9.4.1.4 Primary sidelighted areas>=250 ft2 ❑Complies [EL12)1 are equipped with required lighting ❑Does Not controls. ONot Observable ONot Applicable 9.4.1.5 Enclosed spaces with daylight area ❑Complies [EL13]1 under skylights and rooftop monitors Does Not >900 ft2 are equipped with required lighting controls, ONot Observable ONot Applicable 9.4.1.6 Separate lighting control devices for ❑Complies [EL4)1 specific uses installed per approved ❑Does Not lighting plans. ONot Observable ❑Not Applicable !9.4.2 Exit signs do not exceed 5 watts per ❑Complies [EL6]1 face. Does Not ONot Observable ONot Applicable 19,6.2 Additional interior lighting power ❑Complies [ELS]' allowed for special functions per the ❑Does Not approved lighting plans and is automatically controlled and ONot Observable separated from general lighting. ONot Applicable 10.4.1 Electric motors meet requirements ❑Complies E[EL9]2 where applicable. ❑Does Not ONot Observable ONot Applicable Additional Comments/Assumptions: 1 high Impact(Tier 1) 2 Medium Impact(Tier 2) 3 ,Low Impact(Tier 3) l Project Title: Cycle Bar Report date: 05/17/17 Data filename: C:\Users\Mike Palmer\Dropbox\_(P-2017)\_17.007 GHA-CB-Tigard,OR\_17.007 GHA-CB- Page 9 of 12 Tigard, OR-2014 Oregon Comcheck(UNTOUCHED).cck • Section # Final Inspection Complies? Comments/Assumptions & Req.ID 16.4.3.1,2 Thermostatic controls have a 5 °F ❑Complies [F13)3 deadband. ❑Does Not ❑Not Observable { DNot Applicable 6.4.3.2 Temperature controls have setpoint ❑Complies [F120]3 overlap restrictions. ❑Does Not DNot Observable DNot Applicable 16.4.3:3.1 HVAC systems equipped with at least ❑Complies [F121]3 one automatic shutdown control. ❑Does Not 1 ['Not Observable DNot Applicable 16.4.3.3.2 Setback controls allow automatic ❑Complies [F122]3 restart and temporary operation as ❑Does Not required for maintenance. ❑Not Observable ❑Not Applicable 6.4.3.7 When humidification and ❑Complies [FI6]3 dehumidification are provided to a ❑Does Not zone,simultaneous operation is :Not Observable prohibited. ❑Not Applicable 6.7.2.1 Furnished HVAC as-built drawings ❑Complies [FI7]3 submitted within 90 days of system ❑Does Not acceptance. DNot Observable CINot Applicable 6.7.2.2 Furnished O&M manuals for HVAC ❑Complies (FI8)3 systems within 90 days of system ❑Does Not acceptance. DNot Observable ❑Not Applicable :............ 6.7.2.3 An air and/or hydronic system ❑Complies [F19]' balancing report is provided for HVAC ❑Does Not systems serving zones>5,000 ft2 of ❑Not Observable conditioned area. ONot Applicable 6.7.2.4 HVAC control systems have been ❑Complies 1[FI10]' tested to ensure proper operation, ❑Does Not calibration and adjustment of controls. ❑Not Observable ❑Not Applicable 7.4.4.3 Public lavatory faucet water ❑Complies [F111]3 temperature<=110°F. ❑Does Not DNot Observable DNot Applicable 7.4.4.4 Controls are installed that limit the ❑Complies [F112]3 operation of a recirculation pump ❑Does Not installed to maintain temperature of a storage tank. :Not Observable DNot Applicable 8.7.1 Furnished as-built drawings for ❑Complies [FI16]3 electric power systems within 30 days ❑Does Not of system acceptance. :Not Observable [Not Applicable 8.7.2 Furnished O&M instructions for ❑Complies I[F117]' systems and equipment to the ❑Does Not building owner or designated f` representative. [Not Observable ❑Not Applicable 1 1 !High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Cycle Bar Report date: 05/17/17 Data filename: C:\Users\Mike Palmer\Dropbox\_(P-2017)\_17.007 GHA-CB-Tigard, OR\_17.007 GHA-CB- Page 10 of 12 Tigard,OR-2014 Oregon Comcheck(UNTOUCHED).cck Section . ....__.._.,.,,.... r # Final inspection Complies? i Comments/Assumptions & Req.ID 9.2.2,3 Interior installed lamp and fixture ❑Complies See the Interior Lighting fixture schedule for values. (FliB]' lighting power is consistent with what ❑Does Not is shown on the approved lighting plans,demonstrating proposed watts ONot Observable are less than or equal to allowed ONot Applicable watts. 110.4.3 Elevators are designed with the ❑Complies [F124]2 proper lighting,ventilation power,and ❑Does Not standby mode. ONot Observable [Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Cycle Bar Report date: 05/17/17 Data filename: C:\Users\Mike Palmer\Dropbox\ (P-2017)\_17.007 GHA-CB-Tigard,OR\_17.007 GHA-CB- Page 11 of 12 Tigard,OR-2014 Oregon Com-Check(UNTOUCHED).cck Project Title: Cycle Bar Report date: 05/I7117 Data filename: C:\Users\Mike Palmer\Dropbox\ (P-2017)\ 17,007 GHA-CB-Tigard,OR\_17.007 GHA-CB- Page 12 of 12 Tigard,OR-2014 Oregon Comcheck(UNTOUCHED).cck