Loading...
Report (91) 1 F u s„-uC i Capitol vk , RECEIVED Electrico., Inc. MAR 10 2016 CITY OF BUILDING DIVIS ON March 9, 2016 Plans Examiner City of Tigard Building Services 13125 SW Hall Blvd. Tigard, OR 97223 Re: Tenant Fire Alarm System Additions Lincoln Tower Restroom Remodel, Floors 3, 6, 8, & 10 10260 SW Greenburg Road Tigard, OR 97223 Please find attached building and electrical permit applications, three sets of plans, calculations, and product submittals for the fire alarm tenant improvements at the address shown above. Occupancy Group: B The fire alarm system design includes the following: 1. Relocate and replace with new(4) ADA synchronized fire alarm strobes for each restroom group on floors 3, 6, 8, & 10 per fire alarm plans. (16) Total. 2. We will pre-test the fire alarm devices prior to requesting a final fire alarm inspection. 3. Fire alarm design by Simplex-Grinnell, installation by Capitol Electric Co. Please contact me if you have questions or comments. Re. ctfully, Dan Wilson, SET Project Manager/Estimator Fire/Life Safety Division Capitol Electric Company, Inc. (503) 262-0411 Direct dan@cepdx.com NICET Level IV, Fire Alarm Systems #104512 11401 NE Marx • Portland, Oregon 97220-1041 • 503-255-9488 • Fax 503-257-7121 CCB# 48748 • www.capitolelectricco.com Wheelock® ExcederTM Series COOPER Notification • ,M Finally, Design and Safety Meet... kt tiq u z 6i - 7 Ceilin �_�n• � � �._; Description: The Wheelock®ExcederTM Series of notification appliances feature a sleek modern design that will please building owners with reduced _''Save up to'48% in current draw* total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw,no tools needed for setting changes,voltage test - Up to 9 models now in 1 appliance points, 12/24 VDC operation,universal mounting base and multiple mounting options for both new and retrofit construction. - Save up 1 L�c/O to cost of installation** The Wheelock®ExcederTM Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit.All strobe models feature an industry first of 8 candela settings on a singleU# Sleek Modern Aesthetics appliance.Models with an audible feature 3 sound settings(90,95, 99 dB).All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Olj Finger Slide Switches Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock® ExcederTM Series of wall and ceiling notification 6„ < Voltage Test Points appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting i 4 Multiple Voltages base can be pre-wired to allow full testing of circuit wiring before VDC the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt,dust,paint 3 Audible Settings and damage to the contacts. The Contact Cover also acts as a 90,95,99 dB shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while 8 Candela Settings*** it is on the UMB. When the Contact Cover is removed the circuit Wall-15/1575/30/75/95/110/135/185 will show an open until the appliance is installed.The UMB allows Ceiling-15/30/60/75/95/115/150/177 for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra Universal Mounting Base *** kg) secure installation, while the ceiling models provide a captivated Ceiling and Wall Mounts to 5 Backbox Types screw to prevent the screw from falling during installation. Environmentally Friendly Low Current Draw Compatibility and Requirements -Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock®Patented Sync Protocol -Compatible with UL"Regulated Voltage"using filtered VDC or unfiltered VRMS input voltage -Strobes produce 1 flash per second over the"Regulated Voltage"range "Compared to competitive models "*Patented *"Compared to previous models • NOTE:All CAUTIONS,and WARNINGS are identified by the symbol it.All warnings are printed in bold capital letters. WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS.CAREFULLY BEFORE USING,SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.000PERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: General Notes: •Strobes are designed to flash at 1 flash per second minimum over their"Regulated Voltage Range". •All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. •Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F(0°C to 49°C)and maximum humidity of 93%(±2%)UL 464(85%UL 1971). •Series Exceder horns are under UL Standard 464 for audible signal appliances(Indoor use only). Low Current Draw = Fewer Power Supplies Strobe Ratings per UL Standard 1971 UL Max Current* 24 VDC/24 FWR 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC ST 8.0-33.0 0.057 0.070 0.085 0.135 0.163 0.182 = 0.205 0.253 0.110 0.140 STC 8.0-33.0 0.061 1111113N 0.085 0.103 0.135 0.163 0iitlad4 .182 0.205 0.253 0.110 Horn Strobe Ratings per UL 1971 &UL 464 at 24 VDC UL Max Current*at 99 dBA 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.082 0.095 0.102 gill 0.148 0.176 0.197 = 0.242 EL3IPM 0.282 0.125 0.159 HSC 8.0-33.0 0.082 �1 " ' 0.102 0.141 0.148 0.176 0.197 0.242 0.282 ' 0.125 UL Max Current*at 95 dBA 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC viNiihmq HS 8.0-33.0 0.073 0.083 0.087 lioirol 0.139 0.163 0.186 111F1 0.230 = 0.272 0.122 0.153 HSC 8.0-33.0 0.073 0.087 0.128 0.139 0.163 1771111 0.186 0.230 0.272 „' wm' 0.122 UL Max Current*at 90 dBA 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.065 0.075 0.084 = 0.136 0.157 0.184 0.226 ;. 0.267 0.120 0.148 HSC 8.0-33.0 0 065 pita 0.084 0.120 0.136 0.157 yr,i. 0.184 ',1 0.226 0.2670.120 71- Horn Ratings per UL 464 Model Regulated Voltage 99 dB 95 dB 90 dB '"� �� Range VDC HN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 0.017 g �� HNC 8.0-17.5 0.047 0.026 0.017 *UL max current rating is the maximum RMS current within the listed voltage range(16-33 VDC for 24 VDC units). For strobes the UL max current is usually at the minimum listed voltage,(16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage(33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions. „I 1 y .- I a�' i , n Specification &Ordering Information Sync w/SM, Strobe Mounting Model Candela DSM or 12/24 VDC* N Options PS-6&PS-8x m o Horn Strobes HSR 15/1575/30/75/95/110/135/185 X X UMB** V HSW 15/1575/30/75/95/110/135/185 X X o UMB** 0 HSRC 15/30/60/75/95/115/150/177 X X UMB** W HSWC 15/30/60/75/95/115/150/177 X X °� UMB** V v, To p Strobes v E STR } 15/1575/30/75/95/110/135/185 X Xrilo UMB** STAN 15/1575/30/75/95/110/135/185 X X �i UMB** E STRC T 15/30/60/75/95/115/150/177 X X w UMB** STWC p 15/30/60/75!95/115/150/177 X X d” UMB** Horn c ,hiry _ ..:: to a HNR1. e. UMB** 4-1 HNW CI C' 14'4- ..- UMB** HNRC V (�h X X UMB** W HNWC COal X X 1.- >1 - UMB** . . . . *12 VDC models feature 15&15/75 settings **UMB=Universal Mounting Base fj Model Legend HN = Horn W ST =Strobe ' a1 ° liT ,,, $or,/-,, ,,,1,„k,. ; ,„;$1 ...,/ , e-C",,,,,,oks, HS = Horn Strobe �� C =Ceiling Mount - - W -White i R = Red ,, nth a ry tib.,' a';W� � N Example 1: STRC=Strobe, Red, Ceiling Mount ° Example 2: HSR= Horn Strobe, Red, Wall Mount Example 3: HSW= Horn Strobe, White, Wall Mount pExample h �ple: HSWC P m ...,- as _ . k � �[ .nom 4 y e 0 ° - ' *UMB Contact Cave Voltage test points for quick 8 candela settings Common base for wall and ceiling with 5 troubleshooting and easy spot mounting options checking (wall models only) NOTE:Due to continuous development of our products,specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc.,dba Cooper Notification standard terms and conditions.