Report (73) Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: �S T 2011- - Ob 4lo 9 Jurisdiction: C OF I lr..itilA
Site Address: 1 333 S S60 I L 970 A d'G . ✓ ert_TUi- , O/2 9700
Subdivision/Lot#:
Kko 12..'-let VC-
and/or
Map and Tax Lot#: fj
By my signature below, I certify that a minimum of fifty(50)percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent,or a lighting source that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential Specialty Code N1107.2)1
Signature: / �. Date: 12/10/15
/Gen 'finivr/ uthoriz-• gent
Print Name: .ci SGA G1/L Si r—IJ S 1
1 ORSC Section N1107.2.High-efficiency interior lighting systems. A minimum of fifty(50)percent o the
permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that
has a minimum efficacy of 40 lumens per input watt. Screw-in compact fluorescent lamps comply with this
requirement.
The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the
permanently installed lighting fixtures are compact or linear fluorescent,or a minimum efficacy of 40 lumens per
input watt.
I:\Building\Forms\RES-HighEfficiencyLighting.doc 07/01/08
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
I, LA CA-J121 SV t. S( am the general contractor or the owner-builder
at the following address:
Site Address: 333 5- Sw ) 6911+
City:
Permit#: MSi 2,..r?! ` p0 469
Subdivision/Lot#: !-ST R c v LCL r A-C-
and/or
Map and Tax Lot#:
To conform with the 2008 Oregon Residential Specialty Code(ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes,the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
Signature: Date: 12/ !O//,)
ene C.. +1 .r i ier-Builder
I:\Buildmg\Form\RES-MoistureSensitiveWood.doc 09/25/08
Oregon Residential Specialty Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
I, At—C F.LA C., 410---tSrE1JSEI am the general contractor or the owner-builder
at the following address:
Site Address: 13 3 3 S S w 1 I,I rti AiJJ, (5k/6-44-a , 0 iZ 41-4-00 ?-
City: I-t . ka-
Permit#: 4 ST 201 4-- O b i-I'�,9 N
Subdivision/Lot#: 1,0 Pak f pc ST R,,V ta-T A-c 6
and/or
Map and Tax Lot#: s-
To conform with the 2014 Oregon Residential Specialty Code(ORSC), Section R408.1
Ventilation.I am notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
requirement:
The ground surface of the under-floor space is covered with 6-mil black polyethylene
sheeting 'th
Jo lapped 12"at seams and
xtending up the foundation walls 12".
/ �-
Signature: Ai 4 - Date: J 2/I 0/0
Gene , on'/triffror Owner-Builder
I:1Building\Form\RES-MoistureBarrier.doc 09/13/2016
A