Loading...
Report (122) 'A�- - i nk Q-8-#1C) MOH030X63CFMT - SUBMITTAL Project Name: Project Location Quote-Version#-- Item#: 1000 L, HEATCRAFTSubmitted For: Submitted On- : Worldwide ReMgeraden Submitted By: Submitted From: NOV 118 Identity# Cooler Unit Tag. '}9 3UILDIN 4 \i slm..,i 0 For Record ❑ For Approval By: Date: _ General Product Information Product Family: MOH Compressor Brand: Copeland Application: Outdoor Compressor Type: Hermetic Temperature Range: Extended Temp Compressor Hp: 3 Voltage:(Volts/Ph/Hz) 208-230/3/60 Compressor Model. CS18K6E Refrigerant Type: R404A Number of Compressor(s): 1 Piping: Standard Coil Type: Microchannel Technical Information Ambient Saturated Suction Capacity Altitude AWEF Rating Temperature Temperature (BTU/H) (R) (CF) (°F) 105 25 23,983 0 9.01 Compressor(s) Fan Motor(s) Electric Ratings RLA LRA Quantity Hp FLA Defrost High or Number of MCA MOPD Evap.Fan Defrost Type Low Amps? Contactors Amps Heater Amps 9.4 65.5 1 1/3 3.5 AIR DEFROST NA 15 20 Connections(in) Receiver 90%Full(lbs) Fah Blade(s) Appy.Net Diameter Sound Data Weight Liquid Line Suction Standard Over Sized (in) (dB) abs) 1/2 7/8 20.0 22 73 290 Dimensional Dra C UL US i; it- Page 1 of 8 MOH030X63CFMT- SUBMITTAL Project Name: Project Location: Quote-Version#: Item#: 1000 Submitted For: Submitted On: HEATCRAFT� Submitted By: Submitted From:WorldwJde ReMgeratlon Identity#: Cooler Unit Tag: Standard Features QUALITY SERVICEABILITY • ALL UNITS ARE COMPLETELY LEAK TESTED IN A HELIUM ENVIRONMENT,BUMP • LARGE ELECTRICAL PANEL FOR EASE OF ACCESS TESTED AND ALLOWED TO CYCLE OFF ON THE HIGH AND LOW PRESSURE • PREFABRICATED WRING HARNESSES FOR TIGHT CRIMP CONNECTIONS AND CONTROL. CONSISTENT LABELING • EACH UNIT HAS A COPY OF THE RUN DATA SHIPPED INSIDE THE ELECTRICAL • RECEIVER WTH FUSIBLE PLUG,LIQUID SHUTOFF VALVE AND CHARGING PORT PANEL IS STANDARD • ELECTRICAL CIRCUITS ARE COMPLETELY CHECKED FOR CONTINUITY • SIGHT GLASS IS EASILY VIEWABLE • ENCAPSULATED,AUTO-RESET,HIGH AND LOW PRESSURE CONTROLS TO • SUCTION SERVICE VALVES FOR HERMETIC COMPRESSORS LOCATED OUTSIDE ELIMINATE LEAKS(STANDARD ON ALL HIGH AND MEDIUM TEMPERATURE THE CABINET FOR QUICK INSTALLATIONS. MODELS,ADJUSTABLE LOW PRESSURE CONTROL STANDARD ON LOW • UNIT STAYS ON IF THE HOOD IS REMOVED FOR SERVICING TEMPERATURE MODELS) • PIPING IS LAID OUT TO MINIMIZE STRESS AND VIBRATION AND IS PRE-BENT TO ELIMINATE LEAKS COMPONENT CABINET AND CONSTRUCTION • COMPRESSOR: 1/2 TO 1 HP COMPRESSORS ARE RIGID MOUNTED AND HAVE A • HEAVY DUTY STEEL RAISED BASE WITH 1-1/2"LEGS DISCHARGE LOOP • PAINTED STEEL CABINETS FOR SUPERIOR STRENGTH AND CORROSION • COMPRESSOR: DISCHARGE SERVICE VALVES COME STANDARD ON ALL UNITS PROTECTION • FAN: SPECIFICALLY MATCHED WTH MOTOR AND COIL TO ATTAIN MAXIMUM AIR MOVEMENT AND COOLING Options (iS • DEFROST TYPE-AIR DEFROST • DEFROST TIMER OPTIONS-DEFROST TIMER-AIR • BRAND LABEL OPTION-OEM • CRANKCASE HEATER OPTIONS-CRANKCASE HEATER • DISCHARGE LINE OPTIONS-HEAD PRESSURE VALVE • SUCTION LINE OPTIONS-SUCTION TUBE ONLY • CABINET OPTIONS-PAINTED-OUTDOOR • COIL SELECTION-ALUMINUM FIN COIL • LIQUID LINE OPTIONS-LIQUID STANDARD Minimum Unit Clearances Walls or Obstructions for Multiple Units with Horizontal Air Flow Horizontal Air Flow AIR FLOW AIR FLOW „V-1 AIR W* *W = _ W* FLOW MIN. unit width MIN. W* jtMIN. W* MIN. Page 2 of 8 LCA6110AEQRC6B - SUBMITTAL 171 Project Name Project Location Quote-Version#: Item#: 2000 111 Submitted For: Submitted On: i ;1:1 1 Submitted By: Submitted From: Identity#: Cooler Coil Tag: E For Record ❑ For Approval By: Date: General Product Information Product Family: LCA6 Motor type EC Defrost Type: Air Number of Fans: 2 Voltage:(Volts/Ph/Hz) 115/1/60 Fan HorsePower 1/15 Refrigerant Type: R404A Fins per Inch 6 Technical Information r,x , 14ircirnance Da..- Capacity Air Flow Air Throw R Altitude AWEF Rating TD SST Capacity Fan Diameter () (ft) CFM (°F) (°F) (BTU/H) (ft) Standard w/Collar 10 25 11,000 1,300 12 0 N/A 7114n Motors) Defrost Heater(s) Drain Pan Heater(s) s Amps Watts Amps Watts Amps 2 Connections(in) Appmx.Net Weight Coil Inlet Suction External Equalizer Drain Side Port Hot Gas Drain Pan (lbs) 1/2 7/8 1/4 3/4 51 __ 17 C UL US e N_._..„,, fie e •ter 'r■ -G Page 3 of 8 LCA6110AEQRC6B - SUBMITTAL Project Name: Project Location: Quote-Version#: Item#: 2000 Submitted For: Submitted On: LARKIN Submitted By: Submitted From: Identity#: Cooler Coil Tag: Standard Features EASE OF INSTALLATION&SERVICE PERFORMANCE • ALL ELECTRICAL COMPONENTS FACTORY WIRED TO TERMINAL BOARD AND • INTERNAL PANELS ARE ISOLATED FOR QUIET OPERATION IDENTIFIED,MAKING IT EASY TO FIELD WIRE THE UNIT • INTERNALLY ENHANCED TUBING AND FIN DESIGN FOR HIGHER EFFICIENCY • CABINET DESIGN FEATURES FRONT ACCESS PANELS ON EACH SIDE FOR EASY ACCESS TO ELECTRICAL AND REFRIGERATION COMPONENTS • LIQUID LINE SOLENOID WIRE HARNESS IS FACTORY-INSTALLED FOR QUICK INSTALLATION • MOTORS PLUG INTO WRING HARNESS FOR EASIER SERVICING • ON 4-6 FAN MODELS,DRAIN PAN HAS A LANYARD FOR EASY AND SAFE ACCESS • PRE-DRILLED HOLES ON THE BACK OF THE UNIT FOR ROOM THERMOSTAT RELIABLE&DURABLE VERSATILE • ATTRACTIVE WHITE CABINET • LARGE DIAMETER DRAIN HOLE(3/4"ID)IS LOCATED ON THE BACK OF THE UNIT • MOLDED FAN GUARD DESIGN MADE OF STRONG PLASTIC MATERIAL • MINIMAL HEIGHT OF THE LOW PROFILE SERIES MAKES IT IDEAL FOR LOW • SWEAT CONNECTIONS TO REDUCE POTENTIAL FOR LEAKS CEILING COOLERS Options • Variant condition-null • COIL SELECTION-SIZE 110 ALUM BEACON R404 • COIL COATING-ALUMINUM • COIL MECHANICAL OPTION-BEACON • CONTROL OPTIONS-QRC CONTROLLER • CONTROLS-QRC • VOLTAGE ASSEMBLY SELECTION-115V EC • FAN BLADE SELECTION-STANDARD FAN BLADE • CARTON OPTIONS-STANDARD CARTON • FAN GUARD SELECTION-LARKIN PLASTIC GUARD • NOZZLE SELECTIONS-NOZZLE INSTALLED Minimum Unit Clearances T PLAN VIEW 1vzH 1112H 11j2H PLAN VIEW AIR FLOW 2 yV,, NOTE: 11/2H <- 3H --> 1 1/2 H ~N . eH=Total Height evaporator coil surface. ZZZZ777Z2Z x7777 Two Evaporators One Evaporator Page 4 of 8 MOZ045M63CFT - SUBMITTAL Project Name: Project Location: Quote-Version#: Item#: 3000 Submitted HEATCRAF� Submitted By Subm Submitted From Submitted On �_Wwldwide Refrigeration " Identity# Freezer Unit Tag ❑� For Record ❑ For Approval By: Date: General Product Information Product Family: MOZ Compressor Brand: Copeland Application: Outdoor Compressor Type: Scroll Temperature Range: Medium Temp Compressor Hp: 4 Voltage:(Volts/Ph/Hz) 208-230/3/60 Compressor Model: ZS29KAE-TF5 Refrigerant Type: 8404A Number of Compressor(s): 1 Piping: Standard Coil Type: Microchannel Technical Information _, r ::z 0z., Ambient Saturated Suction Capacity Altitude AVVEF Rating Temperature Temperature (BTU/H) (a) (°F) (°F) 105 -20 14,122 0 9.08 Becht Compressor(s) Fan Motor(s) Eleatic Ratings RLA LRA Quantity Hp FLA Defrost High or Number of MCA MOPD Evap.Fan Defrost Type Low Amps? Contactors Amps Heater Amps 18.4 114 1 1/3 3.5 AIR DEFROST NA 27 40 Unit %ptfications £ Conus(in) Receiver 90%Full(lbs) Fan Blade(s) Approx.Net Sound Data Diameter Weight Liquid Line Suction Standard Over Sized (in) (dB) (lbs) 1/2 1-1/8 20.0 22 73 317 =,eraw I, ' , C 0 us . . f 4 Tile —11. i — -- -3i;le 3Il4 g - on t � 3 1316 42 08 r5114 + .44 . - U4 " I''ir_ -..r f- Page 5 of 8 MOZ045M63CFT - SUBMITTAL Project Name: Project Location: Quote-Version#: Item#: 3000 HFATCRAFT } Submitted For: Submitted On: Worldwide Refrigeration �„/ Submitted By Submitted From: Identity#: Freezer Unit Tag: Standard Features QUALITY SERVICEABILITY • ALL UNITS ARE COMPLETELY LEAK TESTED IN A HELIUM ENVIRONMENT,BUMP • LARGE ELECTRICAL PANEL FOR EASE OF ACCESS TESTED AND ALLOWED TO CYCLE OFF ON THE HIGH AND LOW PRESSURE • PREFABRICATED WRING HARNESSES FOR TIGHT CRIMP CONNECTIONS AND CONTROL. CONSISTENT LABELING • EACH UNIT HAS A COPY OF THE RUN DATA SHIPPED INSIDE THE ELECTRICAL • RECEIVER WTH FUSIBLE PLUG,LIQUID SHUTOFF VALVE AND CHARGING PORT PANEL IS STANDARD • ELECTRICAL CIRCUITS ARE COMPLETELY CHECKED FOR CONTINUITY • SIGHT GLASS IS EASILY VIEWABLE • ENCAPSULATED,AUTO-RESET,HIGH AND LOW PRESSURE CONTROLS TO • UNIT STAYS ON IF THE HOOD IS REMOVED FOR SERVICING ELIMINATE LEAKS(STANDARD ON ALL HIGH AND MEDIUM TEMPERATURE MODELS,ADJUSTABLE LOW PRESSURE CONTROL STANDARD ON LOW TEMPERATURE MODELS) • PIPING IS LAID OUT TO MINIMIZE STRESS AND VIBRATION AND IS PRE-BENT TO ELIMINATE LEAKS COMPONENT CABINET AND CONSTRUCTION • COMPRESSOR: 1/2 TO 1 HP COMPRESSORS ARE RIGID MOUNTED AND HAVE A • HEAVY DUTY STEEL RAISED BASE WTH 1-1/2"LEGS DISCHARGE LOOP • PAINTED STEEL CABINETS FOR SUPERIOR STRENGTH AND CORROSION • COMPRESSOR: DISCHARGE SERVICE VALVES COME STANDARD ON ALL UNITS PROTECTION • FAN: SPECIFICALLY MATCHED WTH MOTOR AND COIL TO ATTAIN MAXIMUM AIR MOVEMENT AND COOLING Options *bunted Op r _. r �.: . ..111111M11111.11111111111111111,„... .;. • DEFROST TYPE-AIR DEFROST • DEFROST TIMER OPTIONS-DEFROST TIMER-AIR • BRAND LABEL OPTION-OEM • CRANKCASE HEATER OPTIONS-CRANKCASE HEATER • DISCHARGE LINE OPTIONS-HEAD PRESSURE VALVE • SUCTION LINE OPTIONS-SUCTION TUBE ONLY • CABINET OPTIONS-PAINTED-OUTDOOR • COIL SELECTION-ALUMINUM FIN COIL • LIQUID LINE OPTIONS-LIQUID STANDARD Minimum Unit Clearances Walls or Obstructions for Multiple Units with Horizontal Air Flow Horizontal Air Flow AIR FLOW AIR FLOW *W= W* AIR W* FLOW MIN.-. 4 unit width MIN. W*MIN. W*MIN. -^ F Page 6 of 8 LCE6160BEQRC6B - SUBMl17AL 1N: Project Name Project Location Quote-Version#: Item#: 4000 Submitted For: Submitted On: Submitted BySubmitted From Identity#- Freezer Coil Tag For Record ❑ For Approval By: Date: General Product Information Product Family: LCE6 Motor type EC Defrost Type: Electric Number of Fans: 4 Voltage:(Volts/Ph/Hz) 208-230/1/60 Fan HorsePower 1/15 Refrigerant Type: R404A Fins per Inch 6 Technical Information Performance Data :. •' rte. ".m4 ,... Capaatfy '. Altitude;r TD SST CapacityFan Diameter Air Throw(ft) (ft) (°F) (°F) (BTU/H) ® (ft) Standard w/Collar 10 -20 16.000 2,600 12 0 N/A Electri 7 Motor(s) Defrost Heater(s) Drain Pan Heaters) Watts Amps Watts Amps Watts Amps 2 236 3,600 15.7 :1,:;is;., ., Connections(in) Approx.Net Weight Coil Inlet Suction External Equalizer Drain Side Port Hot Gas Drain Pan (lbs) 1/2 1-1/8 1/4 3/4 81 ensionat --718 Eiectr ia..: :Lir Knocks>uts w • o N C ul US •.r°i r+-- i iii t.- > , 21/4 f Refrlgeot Electricof 131/4 Connection ErConnection End t 6 1/8--I I--. t, ,4 --i •----6 i/8 '434 L[ . T . T . T .� n- 411 , 1318 1�3 — 1 fL. H -4 1 f 3'4' MP[ 44 NI- i4 i„ s €)roIn s-t• Page 7 of 8 LCE6160BEQRC6B - SUBMITTAL L Project Name: Project Location: Quote-Version#: Item#: 4000 Submitted For: Submitted On: LARKIN Submitted By Submitted From: Identity#: Freezer Coil Tag: Standard Features EASE OF INSTALLATION&SERVICE PERFORMANCE • ALL ELECTRICAL COMPONENTS FACTORY WIRED TO TERMINAL BOARD AND • EXTENDED DRAIN PAN HEATERS FOR MORE UNIFORM DEFROST THROUGHOUT IDENTIFIED,MAKING IT EASY TO FIELD WIRE THE UNIT THE DRAIN PAN AND ADDITIONAL HEAT IN END COMPARTMENTS • CABINET DESIGN FEATURES FRONT ACCESS PANELS ON EACH SIDE FOR EASY • FIXED DEFROST TERMINATION FOR ELECTRIC ACCESS TO ELECTRICAL AND REFRIGERATION COMPONENTS • INTERNAL PANELS ARE ISOLATED FOR QUIET OPERATION • COIL HEATER SLOTS HAVE BEEN ENLARGED FOR EASIER INSTALLATION AND • INTERNALLY ENHANCED TUBING AND FIN DESIGN FOR HIGHER EFFICIENCY REPLACEMENT • REDUCED HEATER WATTAGES • LIQUID LINE SOLENOID WIRE HARNESS IS FACTORY-INSTALLED FOR QUICK INSTALLATION • MOTORS PLUG INTO WRING HARNESS FOR EASIER SERVICING • ON 4-6 FAN MODELS,DRAIN PAN HAS A LANYARD FOR EASY AND SAFE ACCESS • PRE-DRILLED HOLES ON THE BACK OF THE UNIT FOR ROOM THERMOSTAT RELIABLE&DURABLE VERSATILE • ATTRACTIVE WHITE CABINET • LARGE DIAMETER DRAIN HOLE(3/4"ID)IS LOCATED ON THE BACK OF THE UNIT • MOLDED FAN GUARD DESIGN MADE OF STRONG PLASTIC MATERIAL • MINIMAL HEIGHT OF THE LOW PROFILE SERIES MAKES IT IDEAL FOR LOW • SWEAT CONNECTIONS TO REDUCE POTENTIAL FOR LEAKS CEILING COOLERS Options • Variant condition-null • COIL SELECTION-SIZE 160 ALM-BEACON(R404) • COIL COATING-ALUMINUM • COIL MECHANICAL OPTION-BEACON • CONTROL OPTIONS-QRC CONTROLLER • CONTROLS-QRC • VOLTAGE ASSEMBLY SELECTION-230V EC • FAN BLADE SELECTION-STANDARD FAN BLADE • CARTON OPTIONS-STANDARD CARTON • DEFROST TERMINATION FAN DELAY-STANDARD • FAN GUARD SELECTION-LARKIN PLASTIC GUARD • NOZZLE SELECTIONS-NOZZLE INSTALLED Minimum Unit Clearances r /'// Il./ / irar i" PLAN VIEW 11/2H s%I/ 11/21111yzH 4 PLAN VIEW AIR FLOW� NOTE: -0- 11/2H 4- 3H -- 11/2 H �- N J H=Total Height _ ! evaporator coil surface. .r,77 r ' ' Two Evaporators One Evaporator Page 8of8