Loading...
Report (106) 1�Saot - O \� c . S AUTOMATIC SPR/NKLERS GL SER/ES ` ' DRY TYPE a SO r OR L HORIZONTAL SIDEWALL RECESSED HORIZONTAL SIDEWALL DESCRIPTION AND OPERATION The Globe Quick Response GL Series Dry Type Horizontal Sidewall Sprinkler is designed for use in special applications such as freezing environments and N. conditions where sediment or foreign materials might accumulate in ordinary horizontal pipe nipples. f 41 �'i.�o� The Globe Quick Response GL Series Dry Type Horizontal Sidewall Sprinkler �` utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. At the amp le rated temperature, the sprinkler opens releasing the bulb seat, QUICK RESPONSE causing the inner tube assembly to move, allowing the spring assembly to pivot DRY NON-ADJUSTABLE alongside the inner tube. At this time, water flows through the sprinkler and is HORIZONTAL SIDEWALL distributed by the deflector, in an approved discharge pattern. It can be installed wherever standard spray sprinklers are specified but offers the additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a g hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands N increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern. QUICK RESPONSE DRY SLEEVE & SKIRT TECHNICAL DATA HORIZONTAL SIDEWALL • See reverse side for Approvals and Specifications. Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C). s Water Working Pressure Rating - 175 psi (12 Bars). Factory tested hydrostatically to 500 psi (34 Bars).0_ Maximum low temperature glass bulb rating is 67°F ( 55°C). • Frame - bronze • Deflector - brass • Screw :67 brass Bulb seat brass Spring teflon coated nickel alloy QUICK RESPONSE • Retainer brass Pin stainless steel Torsion spring stainless steel DRY RECESSED Bulb glass with alcohol based solution, 3mm Orifice insert- brass HORIZONTAL SIDEWALL 3/4" NPT or 1" NPT Outer tube - galvanized steel pipe Inner tube stainless steel SPRINKLER TEMPERATURE RAT/NG/CLASS/F/CATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER BULB COLOR N.F.P.A. MAXIMUM TEMPERATURES CEILING TEMPERATURE ORDINARY 7 ORANGEIRED '� in .- ' X11 � „„ INTERMEDIATE � �1 �i�` •� YELLOW/GREENV.:'''-'71-500c'''' ,i S a� � ��� ®�tiv_'y 11 HIGH a BLUE 5 0y-10,7:: 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846456.5 89 846 4583 FAX 989-84-- _ 89 846 9231 JULY 2010 A-58 BULLETIN GL5641, REV. #14 QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES DRY TYPE SPECIFICATIONS NOMINAL "K' FACTOR THREAD SIZE LENGTH FINISHES cULus Factory Bronze 5.6 (80 metric) 3/4" or 1" NPT Variable to 48" Satin Chrome' Bright Chrome FM White Polyester 8.1 (116 metric) 1" NPT Variable to Black Polyester 36" Lead Coated2 NOTE: Metric Conversions are approximate. "Finishes available on special order. cULus listed corrosion resistant: Polyester must be specified on order. 'Lead Coated is UL approved only. APPROVALS STYLE SIN CODE K FACTOR THREAD SIZE 135°F 155°F 175°F 200°F 286°F * FM cULus 57°C 68°C 79°C 93°C 141°C HORIZONTAL GL5641 5.6a 1" NPT X X X X X X X SIDEWALL GL5642 5.6a 3/4" NPT X X X X X - X GL8141 8.1° 1" NPT X X X X X - X RECESSED GL5641 5.6a 1" NPT X X X X X X X HORIZONTAL GL5642 5.6a 3/4" NPT X X X X X - X SIDEWALL GL8141 8.1b 1" NPT X X X X X X NOTE:°Listed for light hazard only with deflector from 4"-12"below the ceiling. ('� °l.eted for light and ordinaryllhazard. M with doved 15 from 4'-12" onl the ceiling. IMPORTANT INSTALLATION DATA Recessed Horizontal Sidewall-FM Approved 155'F and 200"F only. l!V//— Horizontal Sidewall-FM Approved 155'F,200"F,and zss'F only. Globe GL Series Dry Horizontal Sidewall sprinklers should be installed in accordance with the requirements set forth in CROSS SECTIONS NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible,the ',T ,' - proper sprinkler head wrench may be used with extreme care ,' 1 for lengths up to approximately 18". Excessive force may distort ' the frame thus destroying the unit. ' `'`f" ' ✓ When installed in a wet system extending into a freezing ,r,. ✓ . area see chart on Dry Caution Sheet for minimum exposed n ow 1 HIi -,,, barrel length to prevent ice plugs. Please refer to our Dry s - Caution sheet for further important installation data. ORDERING INFORMATION " RECESSED ".. SPECIFY EXTENDED HORIZONTAL SIDEWALL •Quantity • Model Number • Style HORIZONTAL SIDEWALL *Orifice • Temperature *Finishes desired •Quantity-Wrenches-P/N 333010 A w,. ®Quantity-Recessed Wrenches-P/N 337014 •Quantity-Protective Caps-P/N 327109-CAP(Friction Fit L l . ,i a`- Recessed) •Escutcheons desired .,o Ii_.,._4\ •"A"Dimension-Distance from face of fitting to the finished „, �,- ceiling regardless of escutcheon used. - µs GLOBE® PRODUCT WARRANTY ,y,::,-;-T.. , ,2 My Globe agrees to repair or replace any of its own manufactured NON-ADJUSTABLE SLEEVE&SKIRT products found to be defective in material or workmanship for a HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale(Our Price List). .,177 L b 4077 AIRPARK DRIVE,STANDISH,MICHIGAN 48658 MCNAMAR CORPORATION 989-846-4583 TAX 989-846-9231 1-800-248-0278 www.globesprinkler.com JULY2010 PRINTED U.S.A. BULLETIN GL5641, REV.#14 IPS CARP*.STEEI..PIP,E.L...EIBETROTECTQW.,VAVES_ Check C UL uS FM VdS LPCB SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS SERIES 717—cULus, FM,VdS, LPCB SERIES 717H HIGH PRESSURE—cULus, FM,VdS, LPCB The FireLock Series 717 Check Valve and Series 717H High Pressure Check Valves are CAD- designed for hydrodynamic efficiency and available in 2"/50mm—3"/80mm(Series 717H)and 21/2"/65mm—12"/300mm(Series 717)sizes. Series 717H valves are cULus Listed and FM Approved for service up to 365psi/2517 kPa.See , chart below for approved services for the Series 717 valves. In both valve designs,the single-disc mechanism incorporates a spring-assisted feature for non- Series 717 slamming operation.This spring-assisted,single-disc design achieves a leak-free seal with as (2 —3765—so mm) little as 5ft/1.5m of head.Series 717 and 717H FireLock Check Valves can be installed either vertically(flow upwards only)or horizontally.A cast flow arrow indicator is provided to assist with proper valve orientation.Both valves include upstream and downstream pressure taps.Each valve is factory-tested to the rated working pressure.For systems requiring a Riser Check option, refer to publication 10.09. Grooved ends allow fast,easy installation with just two Victaulic couplings or the valve may be mounted to flanged(ANSI CL.150)equipment using either to Victaulic Style 741 Vic-Flange®or Style 744 FireLock flange adapters on either end. Series 717 (4—127100—300mm) Approval/Listing Service Pressures ' ' r111141#11' Series 717H Size cULus FM LPCB Vds ,4 2750mm j up to 365 psi/2517 kPa , up to 365 psi/2517 kPa up to 365 psi/2517 kPa [ up to 365 psi/2517 kPa 21/2765 mm up to 365psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa 761 mm up to 365psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa ( upto 365psi/2517 kPa Series 717H High Pressure Check Valve 3780 mm up to 365 psi/2517 kPa r up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365psi/2517 kPa 4'7100 mm n/a _ 5'/125mm n/a ( n/a rVa T..._ rVa .. �.. 139.7 mm :,. n/a 1 n/a r✓an/a 67150 mm 1 rVa r rVa = _.... rVa 1 ria 1651 mm rVa Ni n/a rVa 8/200mm Na •va n/a n/a 4-- 107250 mm i n/an/a [ n/a n/a 127300mm Na n/a t Na n/a Approval/Listing Service Pressures Series 717 Size - ? Oto ;' +(iU, w` ,^=c a^3°� " �Iii .. •= `. VdS ,� .i,. 2'750mm n/a rVa n/an/a 21/2765mm = up to 250 psi/1725 kPa n/a 1 up to 365 psi/2517 kPa i n/a 76.1 mm t... up to 250 psV1725 kPa n/a up to 365 psi/2517 kPa j up to 16bar/232 psi _. 3780 mm uptto 250 ps✓I725 kPa n/a up to 365 psi/2517 kPa u to_l6bar/232 psi 4"/100 mm up to 365pst/2517 kPa up to 365psi/2517 kPa to 3365psi/2517 kPa up to 16bar/232 psi 57125 mm up to 365 psV2517 kPa up to 365 psi/2517 kPa up Jo 365 psi/2517 kPa n/a 139 7m up to 365 psi/2517 kPa up to 365 psi/2517 kPa ' up to 365 psi/2517 kPa up tol6bar/232psi 6"/150mm up to 365ps✓2517kPa € up to 365 psi/2517 kPa ` up to 365 psi/2517 kPa up tol6bar/232psi 165.1 mm a_pato 365 psV2517 kPa up to 365psi/2517 kPa ` up to 365 psi/2517 kPa n/a 87200mm up to365psV2517kPa ' upto365psi/2517kPa up to 348 psi/2430 kPa up to16bar/232psi 10'7250mm up to 250 psV1725 kPa up to 250 psi/1725 kPa ' up to 1725 kPa/250 psi n/a 127300mm u.to 250psV1725 kPa up to 250 psi/1725 kPa I up to 1725 kPa/250 psi n/a JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date WWW.VICTAULIC.COM �CtaulacP VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.10/2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV_P 1(108_1 IPSCARBON STEEL PIPE- FIRE PROTECTION VALVES 10.08 FreLock® SERIES 717-cULus, FM,VdS, LPCB SERIES 717H HIGH PRESSURE-cULus, FM,VdS, LPCB DIMENSIONS-Series 717 Approx. I4--A-*, ( B Y Size Dimensions-Inches/millimeters Wgt.Ea. �II H 0 W Lbs R TYPICAL 2'/-3'/65-80 MM 21/2 2.875 3.88 4.26 3.57 - - - - - 3.6 65 73.0 99 108 91 1.6 76.1 mm 3.000 3.88 4.26 I 3.57 - ......3.6........ < A 76.1 III( 99 • 108 91 - - - - 1.6 !-4.7_,D 33.500 4.25 5.06 1 4.17 _ 4.5 T w� .4 80.... 88.9 108 129 - _.... 106 3 - ' - - - 2.0 'Ani'' P I �1 4 4 500 9 63 6 00 I 3.88 2 75 3.50 2 00 ' 4 50 3 50 3.35 20.0 �'111111111.(i- �� N E 100 114.3 j245 152 99 70 89 51 114 89 85 9.1 I K f .....r-_ 5.563 10.50 6.80 4.50 4.17 215 5.88 4.08 3.98 27.0 I- -+II I En 141.3 - 267 173 _ 114 106 _55_ 149 104 101 12.3 <-B-' -01/FF 0 139.7mm 5.500 `Y-10.50 6.80 I 4.50 _- mm 4.17 . 2.15 , 5.88 4.08 3.98 270 IT %z"NPT Upstream Drain 139.7 I 267 173 ' 114 •• _106 55. ' 149 104 I 101 12.3 0 W NPT Downstream Drain 6 6.625 11.50 8.00 5.00 ) 4.50 2.38 6.67 473 I 3.89 38.0 0 2"NPT(Drain Optional) 150 168.3 292 203 I 127 I 114 61 ` 169 120 I 99 17.2 TYPICAL 4-8"/100-200 MM 165.1 mm 6.500 I 11.50 8.00 ( 5.00 '. 4.50 2.38 , 6.67 4.73 3.89 38.0 165.1 1 292 203 I127 114 61 ' 169 120 _ 99 17.2 8 8.625 14.00 9.88 6.06 5.05 5.65 2.15 8.85 5.65 , 5.75 64.0 <ai 1200 219.1 356 251 154 128 144 55 225 144 ` 146 290 10 10.750 1700 1200 1 709 ' 596 6.69 2.15 1092 673 1000 OC250 273.0 432305 i 180 - 151 170 55 : 277 171 45 4 12 12.750 19.50 1400 806 6.91 Z64 2.51 12.81 Z73 140.0 I�D? 300. 323.9 495 356 j 205 176 194 64 925 196 63.5 K-J 0 '0 4-B-' - J:•- ©Yz"NPT Upstream Drain ®iz"NPT Downstream Drain TYPICAL 10-121250-300 MM DIMENSIONS-Series 717H Approx. Size Dimensions-Inches/millimeters Wgt.Ea. i t . 1,111111111111111 A 4-B-.., wizig ,���kw 7I, y ■! (/►1\1 2 8.66 6.46 V 3.23 1.48 3.02 2.80 4.25 10.7 11M1111/11 '� " �I" _ lJ 60.3 219.8 1641.. 821 37.5 76.7 710 1080 49 �1�,. L �J 2 1/2 I 9.37 1 6.94 3.31 1.66 3.40 3.38 4.38 I ..... 13.8 III?' 73 I 238.0 176.3 84.1 42.2 86.4 85.9 ' 1113 : 6.3 �P 76.1 m m 9.37 6.94 3.31 1.66 3.40 3.38 1 4.38 13.8 [ 238.0 . 176.3 841 42.2 86.4 85 9 I ' 111.3 6.3 TYPICAL 2760.3 mm-3"/88.9 mm ISII 9.62 I 7.44 3.53 1.91 3.65 3.38 - 4.63 20.0 244.3 I 189.0 89.7 - 48.5 92.7 85.9 ? ; 117.6 i 9.1 www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. Ictaulic° 10.08_2 REV_P IPS CARBON STEEL PIPE-FIRE PROTECTION VALV' t 10.08 FireLock° Check Vahfes SERIES 717—cULus, FM,VdS, LPCB SERIES 717H HIGH PRESSURE—cULus, FM,VdS, LPCB MATERIAL SPECIFICATIONS Body:Ductile Iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395,grade 65-45-15,is available upon special request. Body Coating:Series 717H Body: Black Paint Series 717H Endface:Electroless Nickel Series 717(21 —3"):PPS Coating Series 717(4—12"):Black Paint Body Seat:Series 717H—Nitrile 0-ring installed into an electroless nickel plated endface Series 717(21/2—3"):PPS Coated ductile iron Series 717(4—12"):Welded Nickel Disc Seal or Coating: • Grade"T"Nitrile(Series 717H ONLY) Nitrile(Orange color code).Temperature range—20°F to+180°F/-29°C to+82°C.Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range;except hot,dry air over+140°F/+60°C and water over+150°F/+66°C. NOT RECOMMENDED FOR HOT WATER SERVICES. • Grade"E"EPDM(Series 717 ONLY) EPDM(green color code).Temperature range-30°F to+230°F/-34°C to+110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services.NOT RECOMMENDED FOR PETROLUEM SERVICES. * Services listed are General Service Recommendations only.It should be noted that there are services for which these gaskets are not recommended.Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Discs: • Series 717H(2—3"/50—80mm):CF8M Cast Stainless Steel • Series 717(21/2—3"):Aluminum bronze with elastomer seal • Series 717(4—121100—300 mm)Elastomer-coated ductile iron Shaft: • Series 717H(2—3'/50-80mm): Brass • Series 717(21/2—3"):Type 416 Stainless Steel • Series 717(4—127100—300mm)Type 316 Stainless Steel Spring:All sizes Type 302/403 Stainless Steel Shaft Plug: • Series 717H(2—3750—80mm):Type 416 Stainless Steel • Series 717(21/2—12"/65—300 mm):Carbon steel zinc plated Pipe Plug: • Series 717H(2—3"/50—80mm):carbon steel zinc plated • Series 717(4—12'/100—300mm):Carbon steel zinc plated www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. iGtaulic REV__P 10.08.._.3 IPS CARBON STEEL PIPE-FIRE PROTECTION VALVES 10.08 Firelock® SERIES 717—cULus, FM,VdS, LPCB SERIES 717H HIGH PRESSURE—cULus,FM,VdS, LPCB FLOW CHARACTERISTICS The charts below express the flow of water at 60°F/16°C through valve. S717H/717HR 10 vi 0 F F� F ti ti� Lu 0.1 10 100 1000 FLOW RATE-G.P.M. S717H/717HR 100.00 O moo. 6e e� . 10.00 0� u7 i cc a 1.00 100 1000 10000 FLOW RATE(Litres/Min) www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. Nt icoIL.IlIC` 10.O8_4 REV P IPS CARBON STEEL PIPE-FIRE PROTECTION VALVES 10.08 FirelLort' :II hives SERIES 717-cULus, FM,VdS, LPCB SERIES 717H HIGH PRESSURE-cULus, FM,VdS, LPCB FLOW CHARACTERISTICS The charts below express the flow of water at 60°F/16°C through valve. 5717/717R 10 moim n r,,f I i Airir i a AFF F FF FF F� FF a, RF I II O Iv v w w ,v. o,,,,r1 J 1 ti M a h <o v ", 1 4111.11 - _ cc, trl AEI vl I CC I Ii 01 I / 1 10 100 1000 10000 100000 FLOW RATE-G.P.M. 5717/717R 100.00 a= T_0_ I II- AT Afr "' 1 F, F F F O , . FI �<:, .c, ti�cti,, ry.F `,, ,�o�FF w10.00 —.X- v qr, v v — vr ovv cc ti M a h Qo �§3 a`' w acc i , I ___, 1.00 10.00 100 1000 10000 100000 FLOW RATE(Litres/Min) www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICt21Lll1C® REV_13 10.08 .5 10 08 c1,44444,; .P.R.VFECT,19.1141VA 7C- ilreLock® SERIES 717—cULus, FM,VdS, LPCB SERIES 7171-I HIGH PRESSURE—cULus, FM,VdS, LPCB INSTALLATION Series 717 and Series 717H Check Valves can be installed either vertically(flow up only)or horizontally (with hinge on top)-making sure the flow arrow matches the flow direction through the pipeline. Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing.Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com // 10.08 1479 REV P UPDATED 6/2011 VictauIic VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10.08 Open Snoot Assembly FNPTConnection x FNST* nn tion F P P I® Description The single outlet open snoot is constructed of cast brass. The single swivel is complete with gasket and comes standard with pin lugs. Outlet is 21" NPT ' female thread. Comes standard with 21/2" NST female swivel. Kit includes: open snoot, 2 '/2" brass plug with chain, and 21/2" FDC Brass Wall Plate. Installation Specifications Installation can be achieved with tools readily available in the field using common installation practices. Make sure male threads of pipe to which the Cast BBrarass snoot is being attached are liberally coated with a pipe thread sealant such as PipeFit Thread Sealant with PTFE or PTFE Thread Sealant Tape.Tighten the Size: snoot until hand tight.Tighten one additional turn past hand tight to achieve a 21/2 FNPT x F Swivel* water tight seal of the threads. DO NOT OVER TIGHTEN! Over Tightening may *Available Swivels: cause thread failure as well as cracking of the snoot body. NST 3.0686"x 71/2 TPI BCT 3.000"x 8 TPI CLV 3.078"x 8 TPI DET 3.125"x 7'h TPI ONT 3.125"x5TPI PHX 3.062"x 6 TPI QST 3.031"x 7 TPI TEM 3.075"x 6 TPI Check thread dimensions for other 21/2"applications. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL+1 760 599-1168 +1 800 344-1822 cy' FAX+1 800 344-3775 ©2012 Fire Protection Products,Inc. tqco Worldwide www.tyco-fire.com Fire Protection Contacts Products BLAZEMASTER CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet General Technical Description Data '�14 TYCO CPVC Pipe and Fittings pro- Sizes E� duced by Tyco Fire Protection Prod- 3/4 Inch thru 3 Inch ucts (TFPP) are designed exclusively Maximum Working Pressure for use in wet pipe automatic fire 175 psi �# sprinkler systems. The TYCO CPVC Pipe and Fittings are produced from ApprovalsLL and C-UL Listed BLAZEMASTER CPVC compound FM Approved that is a specially developed thermo- LPCApproved . plastic compound composed of post NSF B Certified a a chlorinated polyvinyl chloride (CPVC) MEA of Los Angeles Approved City of Lo resin and state of the art additives. TYCO CPVC Pipe and Fittings are (Refer to Installation Handbook IH-1900 easier to install than traditional steel dated June 2008 for exact listing/approval information.) pipe systems, and at the same time, provide superior heat resistance and Manufacture Source Installation strength as compared to traditional U.S.A. TYCO CPVC Pipe and Fittings are to CPVC and PVC piping materials used Material be to be installed in accordance with in the plumbing trade. Various adapt- Pipe: Installation Handbook IH-1900 dated ers are available to connect CPVC ASTM F442,SDR 13.5 April 2016. pipe to metallic piping.All female pipe Fittings: thread adapters have brass inserts for ASTM F438(Sch.40) durability. Grooved adapters connect ASTM F439(Sch.80) directly to grooved end valves and ASTM F1970 metallic pipe,with flexible grooved end Color couplings. Orange NOTICE The CPVC Pipe and Fittings produced with BLAZEMASTER CPVC compound described herein must be installed and maintained in compliance with this document and with the applicable standards of the National Fire Protec- tion Association (NFPA), in addition to the standards of any authorities having jurisdiction.Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Page 1 of 2 APRIL 2016 TFP1915 TFP1915 Page 2 of 2 Care and Limited Maintenance Warranty TYCO CPVC Pipe and Fittings are to be For warranty terms and conditions,visit maintained and serviced in accordance www.tyco-fire.com with this section. Before closing a fire protection system control valve for inspection or main- tenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must first be obtained from the proper authorities and all person- nel who may be affected by this action must be notified. After placing a fire protection system in service,notify the proper authorities and advise those responsible for moni- toring proprietary and/or central station alarms. The owner is responsible for the inspec- tion,testing, and maintenance of their fire protection system and de-vices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any authority having juris- diction.Contact the installing contrac- tor or product manufacturer with any questions. Automatic sprinkler systems should be inspected,tested,and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. GLOBAL HEADQUARTERS I 1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2016 Tyco Fire Products,LP. All rights reserved. Nee BLAZEMASTER is a trademark of The Lubrizol Corporation. Fire Protection Products '*r� r € f'" ., .x,a.4 "s:' '"' '" "'L, "--+*- T II r. y�q. r is pi' CoA y.3' r+" 411111, -,,tiliall:40111117luill7Willlg.:!,i0i!i:!:::;!;iiii;.r:;:::'ll!,:illaise5:;i:,:::!:::,,,!,,::„:::::::,„:„::::" _ e.„„,o,„„„,,,,, „„L :.:,,,,,,,,,,,,,:„.„,„,,,,.„..,:,,,,, ----,. ...,..,:,„„„,„,,„,,,,,::,,„„,„„ 1,=:,,,,,,,:„,,o :,,,,,,,,,,,,,:,,,,„:„„„„ ,:: , ,„,,f,„„„„,,,,,.„,,, SIDEWINDER° FOR WOOD -Horizontal Application ....„„,::: H:juApplication Product Features a Not less than 2°nominal width f : ; „ ;.;,-...,111t, •No pre drilling required. (1-1/2”)up to 3-1/2°pipe;not less than . ; 3'(2-1/2")nominal width 4"&5"pipe a c'» •Quick to install using the Sammy -ii ° 4 rioor st Nut Driver with an 18V cordless r �_=,.'s" Minimum 2-1/2"from bottom for drill/driver. Ji. branch lines.Minimum 3'from bot- tom for main lines.Exception:This •Saves time from traditional 11 1.r requirement shall not apply to 2°or, methods. 'a t thinker nailing ships resting on top of steel beams. •Reduces installation costs. Made in the U.S.A. t7 : i iv �-' kms` ¥ 1 'i. '"" +..+ rt q". 111 t' 4''Watch a adeo damonstrah'on ar `.=� www.itwbuiidex.com� Rod Part Screw Ultimate UL Test Box Case Approvals Size Number Model Descriptions Pullout(lbs) Load(lbs) Qty Qfy . HORIZONTAL MOU 4 r 1/4" 8019957 SWG 200 1 4 x 2" 125 (Fir) 25 25 t , '">°; ' ° 802b957 YG 10 1,4 x 1" 622 (Fir) 300 25 125 <: 3/8" 8021957 SWG 20 4 x 1725 (Fir) 0 25 25 ` 18" 8073925 WG 20-SS 1'4 x x' 1725(Fir) 850 25 125 ( fix _ Q 3/8"' 8022925 SWG 25-380 3 8 x '2 22 a +,L r; 1.,00 25 125 25 125 g1 #14 SW Red _ a 8" 8023925 G 30 114 x 3" 1884 (Fir) i z Nut Driver . lift Part#8114910 •May require pre-drilling;consult joist manufacturer. LU t SAMMYS SWIVEL HEAD"" FOR WOOD -Swivel Application Application Product Features t) v \i: 41''''':'''.::-:ii 'r;,4'X'"f:',1'. •Eliminates distortion of threaded rod. `� •Accommodates up to 3'% x 12 pitch roof 'AiOit. •Allows 17°deflection from vertical. y R..-3 _ ¥ LI" ;'- •Saves time from traditional methods. ` E •Reduces installation costs. ik ., y, wxr�aew •Made in the U.S.A. r N Rod Part Screw Ultimate UL Test Load FM Test Min Box Case W Approvals Model Size Number Descriptions Pullout(lbs) (lbs) load(lbs) Thickness Qty Qty SWIVEL MOUNT n '` #14 Black 0.Q 3/8 8139957 SH-GST 20 1/4 x 2 1257(Fir) 1050 1475 25 25 !! Nut Driver e.'' 3'8' 8141957 t GST 30 „„ " 172 tr} r- . 1475 25 125 Part#8113910 1903 Dim.Lumber 1500 G 3/8"` 8269957 SH-GST/CST 20 5/16 x 1-3/4" 1406 @ 45°off vertical 81850°°0 45° 25 125 'w Dim Lumber -i o Dm 1;2" 8303957 SH-GST/OST 2.0 5116 x1-314' a a tical 25 (~r..urr,er t #14 SH Orange etNut Driver Ran#8273910 4 4. Q 5 To find a distributor near you,call 800-BUILDEX Pipe Hangers Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line Fig.B3170NF) a ` Fig.200F- "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig.B317ONFF) Fig.200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC) usTEo US Fig.200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm)thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. f � ' Features: s __ • (1/2" (15mm)thru 2" (50mm)) Flared edges ease installation for all pipe ...:r i types and protect CPVC plastic pipe from abrasion. Captured design - 7'.` ; , keeps adjusting nut from separating with hanger. Hanger is easily a . B C installed around pipe. _ . I For hanger with non-captured nut order Fig. 200S. }, a • (21/2" (65mm)thru 8" (20omm)) Spring tension on nut holds it securely in '• A ss., j„:„..„-- hanger �hanger before installation. Adjusting nut is easily removed. / Approvals: Underwriters Laboratories listed (1/2" (15mm)thru 8" 1200mm)) � Fig 200-1/2.2013/4 in the USA(UL)and Canada (cUL)for steel and CPVC plastic pipe and 7 Factory Mutual Engineering Approved(FM) (3/^" (20mm)thru 8" (200mm)). Fig.200-1 to 200-2 Fig.200-21/2 to 200-8 Conforms to Federal Specifications WW-H-171 E &A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69& SP-58, Type 10. R Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel F X materials will be supplied with (2) hex nuts . 'T. in place of a knurl nut. Order By: Figure number and pipe size , Ir Tivt •1 �, s Designed to meet or exceed requirements of FM DS 2-0. ....,-.JJ Fig.200 Fig.200C Fig.200F Pipe Size Rod Size A B Approx.Wt./100 Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) 200-1/2 1/2" (15) 3/8"-1631/8 (79.4) 25/8" (66.7) 11 (5.0) 1 200-3/4 3/4" (20) 3/8"-16 31/8' (79.4) 21/2" (63.5) 11 (5.0) 200-1 1" (25) 3/8"-16 33/8' (85.7) 25/$' (66.7) 12 (5.5) 200-11/4 174" (32) 3/8"-16 33/4" (94.0) 22/8 (73.0) 13 (5.9) 200.11/2 11/2" (40) 3/8"-16 37/8' (98.4) 22/8" (73.0) 14 (6.41 200-2 2" (50) 3/8"-16 41/2" (114.3) 3" (76.3) 15 (6.9) 200-21/2 21/2" (65) 3/8"-16 55/8"" (142.9) 41/8" (104.7) 27 (12.3) 200-3 3" (75) 3/e"-16 52/8 (149.1) 4" (101.6) 29 (13.3) Fig.200S 200-31/2 31/2" (90) 3/8"-16 73/e (187.3) 51/4" (133.3) 34 (15;6) 200-4 4" (100) 3/3"-16 73/8" (187.3) 5" (127.0) 35 (16.0) 200-5 5" (125) 1/2"-13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" 1150) 1/2"-13 101/8" (257.2) 63/4" (171.4) 73 (33.4) 200-8 8"`,(200) 1/2"-13 131/8" (333.4) 83/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. ■ B-Line Fire Protection Solutions 21 by EITAN Pipe Clamps Fig.28M - Offset Hanger&Restrainer for CPVC Plastic Pipe and IPS Steel Pipe ** OTct:~cc .. Size Range: 3/4"(20mm)thru 2' (32mm) COUS Material: Steel, Pre-Galvanized LISTED Function: Designed to be used as a hanger and restrainer for CPVC piping or steel piping where the "stand-off" design will ease installation by eliminating the need for wood blocking. Features: • Flared edge design protects CPVC pipe from any rough or abrasive surfaces • Unique snap-on design holds pipe firmly in place and allows retrofit type of installation f •The "Stand-Off" design eliminates the need for wood block extension • Can be installed on horizontal or vertical piping regardless of mounting surface orientation A •Attaches easily to wood structure with two hex head self-threading screws furnished with product • Installs easily using rechargeable electrical driver with 5/16" (7.9mm)extension socket eliminating impact tool damage to pipe •Attaches easily to steel, minimum 18 gauge(1.024mm)with (2) 1/4" x 1" tek type self drilling tapping screws c •cULus Listed as a hanger and a restrainer for fire sprinkler piping Installation Note: When installed in wood structural members and threads from the --- si� s #10 x 1'screws are exposed, use Fig. 27B speed nut to secure Approvals: Underwriters Laboratory Listed in the USA(UL)and Canada(cUL) to support automatic fire sprinkler systems. May be installed into wood using fasteners screws. Meets and exceeds the requirements of NFPA 13, �1 13R and 13D. Fig. 28M satisfies the UL vertical v restraint requirements where needed. f $•' F; Fig.27B Order By: Figure number and pipe size � ` 1 (2) i14Q�� Required Patent#7,744,042 "` ;� [ill _ ** With reduced spacing, consult factory. �' r �„ t` 1, ;i '„ i - ----- - fl r --y- -i a ^ d d (----+ 2 u__1.1 a a ir---r, Hanger and Restraint ri--i. Application d Qd , L___ a ____J ��� \ > O. - a t ''" Fig.27B r CE r----h ..----.-.11 ---' Restraint GR (1)Required r3 ;; 1----f l High Side of Hanger a • 1. ' IF Restraint Detail A Hanger Application Pipe Size A Hole Dia.B C Max Spacing* Approx.Wt./100 Part No. in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kg) 28M-3/4 3/4' (20) 2" (50.8) 3/16" (4.8) 35/16' (84,1) 5'-6" (1676) 9 (4.1) 28M-1 1" (25) 21/8" (54.0) 3/16" (4.8) 31/2" (88.9) 6'-0" (1829) 12 (5.4) 28M-11/4 11/4" (32) 25/18" (58.7) 3/16" (4.8) 31/2" (88,9) 6`-6" (1981) 13 (5.9) 28M-11/2 11/2" (49) 27/16" (61.9) 3/16" (4.8) 37/8" (98.4) 7'-0" (2133) 14 (6.3) 28M-2 2" (50) 25/8" (66.7) 3/16" (4.8) 47/16"(112.7) 8`0" (2438) 15 (6.8) * Required per NFPA 13 for CPVC plastic pipe All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. ■ Fire Protection Solutions 41 by Pipe Clamps Fig.24- Hanger for CPVC Plastic Pipe&IPS Steel Pipe** ®'rol,c4 Double Fastener Strap Side Mounted (B-Line 83183) cC )05 Size Range: 3/4"(20mm)thru 2'(50mm) CPVC pipe LISTED' Material: Pre-Galvanized Steel Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom -of a beam. Approvals: Underwriters Laboratories Listed in the USA-(UL)and ' Canada(cUL)to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge(0.912mm)steel i using (2) 1/4"x 1"tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. ,' Features: Fig.24 incorporates features which protect the pipe and i + ease installation.The flared edge design protects the CPVC pipe from j ". Ii any rough surface. Easily attaches to the building structure using the 1 \,,,, 7 //' two UL Listed hex head self threading screws*furnished with the 1 '-'...,7_-_-;/ product. It is recommended that rechargeable electric drills fitted with 1 , a hex socket attachment be used as installation tools. No impact tools (such as a hammer)are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. " e Finish: Pre-Galvanized ("' ����"� B Order By: Figure number and pipe size � `' A-_ �1... * Hardened hex head self threading screw is furnished with the `" product and is the minimum fastener size acceptable. ** With reduced spacing, consult factory. CPVC Max.Hanger Fastener Hex Approx. Pipe Size A B C Spacing Head Size Wt./100 Part No. in. (mm) in. (mm) in. (mm) in. (mm) Ft. (m) in. (mm) Lbs. (kg) 24-3/4 3/4° (20) 25/16" (58.7) 15/32" (27.8) 13/16 (30.2) 51/2 (1.67) 5/16" (7.9) 9 (4.1) 24-1 1" (25) 25/8" (66.7) 15/16" (33.3) 13/16' (30.2) 6 11.83) 5/16" (7.9) 9 (4.1) 24-11/4 11/4" (32) 3" (76.2) 11/2" (38.1) 13/16" (30.2) 61/2 (1.98) 5/16 (7.9) 11 (5.0) 24-11/2 11/2" (40) 31/4' (82.5) 15/8" (42.3) 13/16" (30.2) 7 (2.13) 5/16" (7.9) 12 (5.4) 24-2 2" (50) 311/16" (93.7) 127/32" (43.6) 13/16" (30.2) 8 (2.44) 5/16" (7.9) 15 (6.8) 72 Fig.25 - Surge Restrainer131 ittS CL o Size Range:—One size fits 3/4" (20mm)thru 2"(40mm)pipe. 1 \ LISTED Material:—Pre-Galvanized Steel \___ H Function:—Designed to be used in conjunction with Fig. 200 band .� hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity.The surge restrainer is easily and efficiently installed by snapping into a locking position on the (i...,d; band hanger. This product is intended to satisfy the requirements as l' li indicated in the National Fire Protection Association NFPA 13, 2010 `! edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel 's;i,`•: pipe or CPVC plastic Pipe. ! �'� `T 'i 1 Approvals:—Underwriters Laboratories Listed only when used with 14 band hanger Fig.200, in the USA(UL)and Canada(cUL). Finish: Pre-Galvanized Order By: Figure number and band hanger, size from 3/4" (20mm)thru 2" (40mm). Ta' f Patent#5,344,108 '' ` All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. r-Line by 38 Fire Protection Solutions f - , RESIDENTIAL " OR an AUTOMATIC SPRINKLERS L. } MODEL GL4110 & GL4910 FIRE SPRINKLER CORPORATION PENDENT RECESSED PENDENT DESCRIPTION AND OPERATION The Globe Model GL4110 and GL4910 Residential Sprinklers have a low profile yet durable design which utilize a 3mm frangible glass ampule as the thermosensitive element. Theyfeature economy, aesthetics and low flow. The combination of the 3mm frangible glass ampule and spe- cially designed deflector make the Model GL4110 and GL4910 Residential Sprinklers the ultimate in life safety and fire control. These Globe Pendent and Recessed Pendent Residential Sprin- klers have met the strict requirements of Underwriters Laboratories Inc.as described in the UL Standard for Residential Sprinklers for Sil ft. Fire Protection Service, UL 1626,and should be used accordingly. VT These sprinklers should also be installed in accordance with the appropriate NFPA Standard 13, 13D or 13R and under the direc- tion of the approving authorities having jurisdiction. RESIDENTIAL The heart of Globe's Model GL4110 and GL4910 sprinklers PENDENT proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed,the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pres- sure within the ampule exceeds the strength ofthe glass causing the glass to shatter. This results in water discharge which is distributed - in an approved pattern. TECHNICAL DATAI , '4,'- .-,: , '.. -- - •See reverse side for Approvals and Specifications. , *Temperature Rating - 155°F(68°C), 175°F (79°C). .i,„ *Water Working Pressure Rating - 175 psi (12 Bars). •Factory tested hydrostatically to 500 psi(34 Bars). RESIDENTIAL •Maximum low temperature glass bulb rating is-67°F(-55°C). RECESSED PENDENT Frame - bronze • Deflector- brass * Screw - brass *Bulb seat-copper • Spring - nickel alloy a Seal -teflon *Bulb-glass with alcohol based solution, 3mm size. •Escutcheon Assembly-steel *SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER BULB N.F.P.A.MAXIMUM TEMPERATURES COLOR CEILING TEMPERATURE ORDINARY 165° f!„ t RE) d li, l® �� ,�1� o INTERN®IATE i�7 J1,,h, ° - YELLOW 49)1 Via: 4077 AIRPARK DRIVE,STANDISH,MICHIGAN 48658 989-846-4583 . FAX989-846-9231 SEPTEMBER2010 A-1 BULLETIN GL4110/GL4910,REV.#6 RESIDENTIAL AUTOMATIC SPRINKLERS MODEL GL4110 & GL4910 PENDENT e. RECESSED PENDENT SPECIFICATIONS AND APPROVALS SIN THREAD 155°F 175°F NYC-DOB MODEL K FACTOR SIZE LENGTH FINISHES 68°C 79°C3 cULus MEA 101-92-E Factory Bronze GL4110 4.1 (58 metric) Satin Chrome' 1/2" NPT 2 1/2" Chrome X X X X (6.4 cm) White Polyester2 4. GL4910 Nom9nal (68 metric) Black Polyester2 Lead Coated' NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'FINISHES AVAILABLE ON SPECIAL ORDER. C-U.L.LISTED CORROSION RESISTANT- POLYESTER MUST BE SPECIFIED ON ORDER. INSTALLATION DATA 3 GL4110 ONLY LISTED 175°F FOR 12'X 12'ROOM PENDENT AND RECESSED PENDENT MODEL MAXIMUM AREA MINIMUM WATER DISCHARGE & OF COVERAGE PRESSURES NEEDED PER SPRINKLER " 12' x 12' 11 G.P.M. -7.2 P.S.I. GL4110 14' x 14' 12 G.P.M. - 8.6 P.S.I. 16' x 16' 14 G.P.M. - 11.7 P.S.I. PENDENT AND RECESSED PENDENT 12' x 12' 13 G.P.M. - 7 P.S.I. 14' x 14' 14 G.P.M. - 8.2 P.S.I. GL4910 16' x 16' 14 G.P.M. - 8.2 P.S.I. 18' x 18' 18 G.P.M. - 13.5 P.S.I. 20' x 20' 20 G.P.M. - 16.7 P.S.I. *WHEN THESE SPRINKLERS ARE USED IN NFPA 13 SYSTEMS,A 0.1 DESIGN DENSITY MINIMUM SHALL BE UTILIZED. CROSS SECTION ORDERING INFORMATION SPECIFY " - Quantity 4 Model Number ° Style Orifice Temperature Finishes desired Quantity-Wrenches- P/N 325390 A =Quantity - Recessed Wrenches - P/N 325391 Quantity-Proctective Caps-P/N 327109-CAP „ M;r (Friction Fit Recesed) I, I 185/8" MAX. GLOBE° PRODUCT WARRANTY / f r - I4 4 Globe agrees to repair or replace any of its own �' \ I it .. ,, manufactured products found to be defective in mate- CF J \t X rial or workmanship for a period of one year from date of shipment. -AN-< For specific details of our warranty please refer to 1/2"ADJUSTMENT RECESSED PENDENT Price List Terms and Conditions of Sale(Our Price List). 4077 AIRPARK DRIVE,STANDISH,MICHIGAN 48658 G `B E 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkler.corn FIRE SPRINKLER CORPORATION SEPTEMBER2010 PRINTED U.S.A. BULLETIN GL4110/GL4910,REV.#6 E RESPONS QUICK , rr AUTOMATIC SPRINKLERS rE2 su GL SERIES WT UPRIGHT PENDENT ***.0°FG..IR VERTICAL SIDEWALL WO 76 ..c0g.t..-.4L',-1I4 .1,,-:.°-.W-4-_-,`rp- HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. t While the Quick Response Sprinkler provides an aesthetically ,, pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design requirements. Quick QUICK RESPONSE Response Sprinklers should be used advisedly and under the UPRIGHT CONVENTIONAL direction .f approving authorities having jurisdiction. ,Kc The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that s. contains a precisely measured amount of fluid. When heat is ° absorbed, the liquid within the bulb expands increasing the internal ; pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed a' in an approved pattern depending upon the deflector style used. c UK RESPONSE TECHNICAL DATA PENDENT VERTICAL *See reverse side for Approvals and Specifications. SIDEWALL Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C) Water Working Pressure Rating - 175 psi (12 Bars) t V Factory tested hydrostatically to 500 psi (34 Bars) Maximum low temperature glass bulb rating is -67°F (-55°C) QUICKRESPONSE *Frame - bronze Deflector- brass Screw - brass HORIZONTAL LPC/CE Lodgement Wire - stainless steel SIDEWALL HORIZONTAL $Bulb seat - copper Spring - nickel alloy Seal - teflon SIDEWALL Bulb - glass with alcohol based solution, 3mm size SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER BULB COLOR N.F.P.A. MAXIMUM TEMPERATURES CEILING TEMPERATURE ORDINARY i " •®'4ORANGE/RED ' INTERMEDIATE YELLOW/GREEN ; HIGH BLUE ,i « . __ , ,_ .. 4077AIRPARKDRIVE,STANDISH,MICHIGAN 48658 989-8464 83 FAX JULY 2012 A-20 BULLETIN GL5615, REV. #9 QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT 0 PENDENT 0 VERTICAL SIDEWALL HORIZONTAL SIDEWALL 0 CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH' FINISHES 2.8 (39 metric) 1/2" NPT 2 1/4" (5.7cm) Factory Bronze 4.2 (59 metric) 1/2" NPT 2 1/4" (5.7cm) 5.6 (80 metric) 1/2" NPT 2 1/4" (5.7cm) Chrome 7.8 (111 metric) 1/2" NPT 2 1/4" (5.7cm) White Polyester 3 8.1 (116 metric) 3/4" NPT 2 7/16" (6.2cm) Black Polyester 2,3 METRIC CONVERSIONS ARE APPROXIMATE. I HORIZONTAL SIDEWALL IS 2 9/16". 2 FINISHES AVAILABLE ON SPECIAL ORDER. 2 AVAILABLE AS cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. APPROVALS STYLE SIN K HAZARD' 135°F 155°F 175°F 200°F 286°F cULus FM LPC CE NYC-DOB MODEL FACTOR 57°C 68°C 79°C 93°C 141°C MEA 101-92-E GL2815 2.8 LH X X X X X X — — — X GL4215 4.2 LH X X X X X X — — — X UPRIGHT GL5615 5.6 LH/OH X X X X X X X X X X GL8115 7.8* LH/OH X X X X X X — — — X GL8118 8.1 LH/OH X X X X X X X X X X GL2801 2.8 LH X X X X X X — — — X GL4201 4.2 LH X X X X X X — — — X PENDENT GL5601 5.6 LH/OH X X X X X X X X X X GL8101 7.8* LH/OH X X X X X X X — — X GL8106 8.1 LH/OH X X X X X X X X X X VERTICAL GL5632 5.6 LH X X X X X X X — — — SIDEWALLt GL8133 8.1 LH X X X X X X — — — — GL2826§ 2.8 LH X X X X X X — — — X HORIZONTAL GL4226§ 4.2 LH X X X X X X — — — X SIDEWALL GL5626§ 5.6 LH/OH X X X X X X X — — X GL5627u 5.6 LH/OH X X X X X — — X X — GL8127§ 8.1 LH/OH X X X X X X — — — — CONVEN11oNAL GL5624 5.6 LH/OH X X X X X — — X X — (OLD STYLE) GL8125 8.1 LH/OH X X X X X — — X X — 1SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS. §HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4"TO 12"BELOW THE CEILING,FM APPROVED 4"TO 6"BELOW THE CEILING. aINSTALL IN ACCORDANCE TO BS5306 AND ANY OTHER RELATED DOCUMENTS. ?PENDENT VERTICAL SIDEWALL cULus LISTED FOR 6'MIN.SPACING. tUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9'MIN.SPACING. OH: ORDINARY HAZARD LH: LIGHT HAZARD *1/2"NPT ORDERING INFORMATION GLOBE®PRODUCT WARRANTY SPECIFY *Quantity a Model Number * Style Globe agrees to repair or replace any of its own manufactured *Orifice * Thread Sizes * Temperature products found to be defective in material or workmanship for a Finishes desired period of one year from date of shipment. Quantity-Wrenches- P/N 325390 (1/2"); For specific details of our warranty please refer to Price List P/N 312366 (L.O.) Terms and Conditions of Sale (Our Price List). G 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkler.corn FIRE SPRINKLER COR° RON JUNE 2012 PRINTED U.S.A. BULLETIN GL5615,REV.#9