Loading...
Plans (87) 74'-4" LEGEND 12761 SW 133rd Ave INV INVERTER&DC DISCONNECT BLUE RAVEN I-,_ N SUB (E) SUBPANEL LC (N) LOAD CENTER 1220 S.630 E STE,430 AMERICAN FORK,UT 84003 AC AC DISCONNECT 800-377-4480 W WW.BLUERAVENSOLAR.COM FRONT OF HOME M UTILITY METER!SERVICE PANEL CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT JB JUNCTION BOX BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE C COMBINER BOX RECIPIENTS ORGANIZATION. EXCEPT IN CONNEC TION WITH THE 0 PV REVENUE METERSALE AND USE OF THE RESPECTIVE PV PV REVENUE EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. FIRE SETBACK i//!/ >- (n O EMT CONDUIT RUN W Ill " 0 a- d�- (TO BE DETERMINED IN FIELD) o Z � H 0 b. 1:11 D Illil 11 ZK ° IN-- < PV WIRE STRING Q C0 ct W co, II CD 0 ~ Co 12) ~ O PROPERTY LINE U 0cl) 0 rul: c43 AIr/aI #101////!A////ice///!�///�// Ad145/ Ag w U U m 97'-7" • ■ ■ ■ ■ ■ ■ SCALE: 3132"= 1'-0" 0 (n ioiiiiiiiiiiiiiA a 0 � M P 1 100'-9" AZIMUTH:182' iffc Og° 0 B c c PITCH:26° 0 iffc Pic Iffo tic Pk Iic TSRF:85% 0 z ON c`i LU Q Q ti N 2 -2 03 Ua IX >, 02 z a- O () w - - U) -- I- N 0 1 AC DISCONNECT TO BE LOCATED (!) z .- I- a 0-i WITHIN 10' OF UTILITY METER DRAWING BY ROOF ATTACHMENTS SHALL BE SPACED Carlin Johnson NO GREATER THAN 24" ON CENTER IN ANY DIRECTION WHERE LOCATED DATE November 9, 2018 WITHIN 3' OF A ROOF EDGE, HIP, EAVE, OR RIDGE OSSC 3111.5.3 ITEM 3.35 PROJECT NUMBER DC SYSTEM SIZE: 3.54 kW DC 55564675 ROOF TYPE: Comp Shingle SHEET NAME PROPERTY PLAN (12) Sunmodule Plus SW 295M Black 76'-2" Enphase IQ7-60-2-US,----INVERTER PAGE NUMBER REVISION PV2 0 LEGENDNilNor- NINV INVERTER&DC DISCONNECT BLUE RAVEN (1:iiiil SUB (E) SUBPANEL LC (N) LOAD CENTER 1220 S.630 E STE.430 AMERICAN FORK,UT 84003 AC AC DISCONNECT 800-377-4480 WVVW BLUERAVENSOLAR.COM M UTILITY METER/SERVICE PANEL CONFIDENTIAL-THE INFORMATION FRONT OF HOME HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT JB JUNCTION BOX BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE C COMBINER BOX RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE PV PV REVENUE METER EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF r�t� BLUERAVENSOLAR LLC. % ; FIRE SETBACK L } O L U) cp CO J EMT CONDUIT RUN Wd w (TO BE DETERMINED IN FIELD) 0 Z Q Q D ch U 0 ti M MS_I PV WIRE STRING < ° .71. Et w CO, ❑ I ~ C° Z w O AC Icr PROPERTY LINE U 0 COO LI U U m C —) .., SCALE: 1/8"= 1'-0" 0r eliSMai o r 12" '////ff//r/// ///r1///r///r////z///// 12" — //////////////// J B p Ifc Ifc 1 MP1 I[c Vic 0 0 JB Ofc Latc AZIMUTH:182' . . PITCH:26° Z ! f f TSRF:85% - 0 Q co N c c c c c c UJ r` 0 cn rt >. () o 2 O co O U o - co -O- W cn 03 co Uin cn z .- F o c-i DRAWING BY Carlin Johnson DATE November 9, 2018 PROJECT NUMBER DC SYSTEM SIZE: 3.54 kW DC 55564675 ROOF TYPE: Comp Shingle SHEET NAME SITE PLAN (12) Sunmodule Plus SW 295M Black Enphase IQ7-60-2-US,----INVERTER PAGE NUMBER REVISION PV3 0 PV ARRAY STRUCTURAL CRITERIA PV MODULE(BEHIND TRIM RAIL) Unirac Sunframe Microrail TRIM RAIL PV MODULE COUNT: 12 MODULES <> <-7.,,! BLUE RAVEN #OF ATTACHMENT POINTS: 42 g LANDSCAPE � 1'-11 ' ARRAY AREA: Module Count x 17.51ft2= 210.1ft2 _MAX. 48"MAX. ROOF AREA: 1880.3ft2 1220 S 630E STE.430 % OF ARRAY/ROOF: 11.2°!° AMERICAN FORK,UT 84003 PORTRAIT ARRAY WEIGHT: Module Count x 501bs =600.0Ibs 800-377-4480 1' 11" 48" MAX. WWW.BLUERAVENSOLAR COM DISTRIBUTED LOAD: Array Weight_Array Area = 2.86 lbs/ft2 MAX. ARRAY DETAIL, FRONT VIEW CONFIDENTIAL-THE INFORMATION POINT LOAD: Array Weight_Attachments = 14.3Ibs/attachment SFM Raised Seal Flashing HEREIN CONTAINED SHALL NOT BE Scale: 3/8"= I'-O" USED FOR THE BENEFIT OF ANYONE EXCEPT Unirac Sunframe Microrail FRAME BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ASCE 7-10 WIND SPEED: 110 MPH EXPOSURE CATEGORY: C !...... PORTRAIT PART TO OTHERS OUTSIDE SITE CRITERIAljel RECIPIENTS ORGANIZATION. GROUND SNOW LOAD: 10 PSF SEISMIC DESIGN CATEGORY: D EXCEPT IN CONNEC TION WITH THE r--- SALE AND USE OF THE RESPECTIVE "��` EQUIPMENT.WITHOUT THE WRITTEN PERMISSION OF Unirac Sunframe Microrail .4� BLUERAVENSOLAR LLC. UNIRAC TRIMRAIL � MODULE '611 .II °II LANDSCAPE >Y } o Lct) o WW "I- 0 - d1- Sunmodule Plus SW 295M Black WIDTH O U O u_ PV MODULE Z / \ i+� 26 ARRAY DETAIL, SIDE VIEW„ f- l�>- ct (E) ROOF I— — O H o 1 y MEMBRANE ` Scale. 318 - l'-0"*11 O O Ik Mi 2.5' MODULE W U m i 1 C UNIRAC LIDER AND —)O = TRIMRAIL ROOF ATTACHMENTS WIDTH 0 CC O 6 I 11 - m TO S – FLASHING fn 2.5" MIN. EMBED. F- - 5/16"STAINLESS STEEL LAG BOLT ROOF TYPE: Comp Shingle ROOF ATTACHMENTS SHALL BE SPACED W WITH 2-1/2" MIN. EMBEDMENT NO GREATER THAN 24" ON CENTER IN ROOF FRAMING TYPE: Manufactured Truss e AND FLAT WASHER ANY DIRECTION WHERE LOCATED - (E) BUILDING RAFTER OR TOP CHORD(TRUSS)2x4 @ 24"0.0. WITHIN 3' OF A ROOF EDGE, HIP, SAVE, STRUCTURE CEILING JOIST OR BOTTOM CHORD(TRUSS)2x4 @ 24"0.0. OR RIDGE OSSC 3111.5.3 ITEM 3.35 Oo co ili Unirac Sunframe Microrail Q < r N IY , co > o 2 Q Sunmodule Plus SW 295M Black Li_ i1 O (17) 0 Z PV MODULE U) ct, -:t. A ....... N. 7 U "' U) Z - H 0 c, I ��y (E)ROOF 2.5" MEMBRANE DRAwiNG BY = Carlin Johnson �� i UNIRAC SLIDERS DATE November 9, 2018 IIz2.5" MIN. EMBED. FLASHINGPROJECT NUMBER 55564675 5/16"STAINLESS STEEL LAG BOLT WITH 2-1/2" MIN. EMBEDMENT SHEET NAME AND FLAT WASHER EQUIP. DETAIL (E) BUILDING STRUCTURE PAGE NUMBER REVISION PV4 0 MODULE SPECIFICATIONS Sunmodule Plus SW 295M Black DESIGN LOCATION AND TEMPERATURES CONDUCTOR SIZE CALCULATIONS RATED POWER(STC) 295 W TEMPERATURE DATA SOURCE ASHRAE 2%AVG. HIGH TEMP MICROI NVERTER TO /1AX.SHORT CIRCUIT CURRRENT(ISC)= 12.0 A AC \err MODULE VOC 40 V DC STATE Oregon JUNCTION BOX MAX.CURRENT(ISC X1.25)= 15.0 A AC MODULE VMP 32 V DC CITY Tigard CONDUCTOR(TC-ER,COPPER(90°C))= 12 AWG BLUE RAVEN MODULE IMP 9.5 ADC WEATHER STATION PORTLAND INTERNATIONAL AP CONDUCTOR RATING= 30 A MODULE ISC 10 A DC ASHRAE EXTREME LOW TEMP(°C) -6 AMB.TEMP.AMP.CORRECTION= 0.96 VOC CORRECTION(%/°C) -0.3 °C ASHRAE 2%AVG.HIGH TEMP(°C) 32 ADJUSTED AMP.= 28.8 > 15.0 1220 S.630 E STE.430 VMP CORRECTION (%/°C) -0.4 °C JUNCTION BOX TO .TAX.SHORT CIRCUIT CURRRENT(ISC)= 12.0 AAL AMERICAN FORK,UT 34003 SERIES FUSE RATING 25 A DC SYSTEM ELECTRICAL SPECIFICATIONS CIR 1 CIR 2 CIR 3 CIR 4 CIR 5 CIR 6 COMBINER BOX MAX.CURRENT(ISC X1.25)= 15.0 A AC 600-377-4480 WWW.BLUERAVENSOLAR.COM ADJ.MODULE VOC @ ASHRAE LOW TEMP 43.8 V DC NUMBER OF MODULES PER MPPT 12 CONDCUTOR(UF-B,COPPER(60°C))= 12 AWG ADJ. MODULE VMP @ ASHRAE 2%AVG.HIGH TEMP 26.2 V DC DC POWER RATING PER CIRCUIT(STC) 3540 CONFIDENTIAL-THE INFORMATION CONDUCTOR RATING= 20 A HEREIN CONTAINED SHALL NOT BE TOTAL MODULE NUMBER 12 MODULES CONDUIT FILL DERATE= 1 USED FOR THE BENEFIT OF MICROINVERTER SPECIFICATIONS Enphase IQ7-60-2-US STC RATING OF ARRAY 3540W DC AMB.TEMP.AMP.CORRECTION= 0.96 BLUERAVENNSOLEARXNOR SHALL IT POWER POINT TRACKING(MPPT) MIN/MAX 22 - 48 V DC AC CURRENT @ MAX POWER POINT(IMP) 12.0 ADJUSTED AMP.= 19.2 > 15.0 BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE MAXIMUM INPUT VOLTAGE 48 V DC MAX.CURRENT(IMP X 1.25) 15 EGC ISC= 12.0 A AC RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE MAXIMUM DC SHORT CIRCUIT CURRENT 15 A DC OCPD CURRENT RATING PER CIRCUIT 20 MAX.CHANNEL ISC= 15.0 A AC SALE AND USE OF THE RESPECTIVE MAXIMUM USABLE DC INPUT POWER 350 W MAX.COMB.ARRAY AC CURRENT IMP 12.0EQUIPMENT,WITHOUT THE (IMP) INDUCTOR(THWN 2,COPPER(90°C))= 10 AWG WRITTEN PERMISSION OF MAXIMUM OUTPUT CURRENT 1 A AC MAX.ARRAY AC POWER 2880W AC EGC CONDUCTOR RATING= 20 A BLUERAVENSOLAR LLC. AC OV ERCURRENT PROTECTION 20 A CONDUIT FILL DERATE= 1 } o C W o MAXIMUM OUTPUT POWER 250 W AC VOLTAGE RISE CALCULATIONS DIST(FT) VRISE(V) VEND(V) %VRISE IQ7-6 AMB.TEMP.AMP.CORRECTION= 0.96 W 1";•] O n 4 CEC WEIGHTED EFFICIENCY 97 % VRISE SEC. 1(MICRO TO JBOX) 21.6 0.52 240.52 0.22% ADJUSTED AMP.= 19.2 > 15.0 0 I H O VRISE SEC.2(JBOX TO COMBINER BOX) 35 1.70 241.70 0.71% COMBINER BOX TO INVERTER RATED AMPS= 12.0 A AC Z D IX CO < 0 uj M AC PHOTOVOLATIC MODULE MARKING(NEC 690.52) VRISE SEC.3(COMBINER BOX TO POI) 20 0.61 240.61 0.25% MAIN PV OCPD MAX.CURRENT(RATED AMPS X1.25)= 15 A AC 2 H uj H IL p NOMINAL OPERATING AC VOLTAGE 240 VAC TOTAL VRISE 1.18% INDUCTOR(THWN-2,COPPER(75°C))= 10 AWG H I- Z CD NOMINAL OPERATING AC FREQUENCY 47-68 HZ AC CONDUCTOR RATING= 35 A W O O m MAXI MUM AC POWER 240 VA AC PHOTOVOLTAIC AC DISCONNECT OUTPUT LABEL(NEC 690.54) CONDUIT FILL DERATE= 1 -) Cn MAXIMUM AC CURRENT PER CIRCUIT 12.0 A AC AC OUTPUT CURRENT 12.0 A AC AMB.TEMP.AMP.CORRECTION= 0.96 O CK MAXIMUM OCPD RATING PER CIRCUIT 20 AAC NOMINAL AC VOLTAGE 240 V AC ADJUSTED AMP.= 33.6 > 15.0 CL GROUNDING NOTES 10. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZE ACCORDING TO[NEC 6. PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 1. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH[NEC 690-47]AND 690.45] AND BE A MINIMUM OF#10AWG WHEN NOT EXPOSED TO DAMAGE(#6AWG INSULATED. 90°C RATED.WET AND UV RESISTANT, RATED FOR 600V Z [NEC 250-50]THROUGH[NEC 250-60]SHALL BE PROVIDED. PER NEC, SHALL BE USED WHEN EXPOSED TO DAMAGE). 7.4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER 0 > ccs) W GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND 11.GROUNDING AND BONDING CONDUCTORS, IF INSULATED,SHALL BE COLOR VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS. Q Q N BONDED TO AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE, CODED GREEN(OR MARKED GREEN IF#4 AWG OR LARGER) 8.ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION 2 -2 � C/) OR INADEQUATE,OR IS ONLY METALLIC WATER PIPING,A SUPPLEMENTAL 12. ALL CONDUIT BETWEEN THE UTILITY AC DISCONNECT AND THE POINT OF 9.VOLTAGE DROP LIMITED TO 2%FOR DC CIRCUITS AND 3%FOR AC CIRCUITS Q' ›, co 0 2 GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONNECTION SHALL HAVE GROUNDED BUSHINGS AT BOTH ENDS. 10. NEGATIVE GROUNDED SYSTEMS DC CONDUCTORS SHALL BE COLOR CODED AS 0 5 ' Wu CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP. 13.SYSTEM GEC SIZED ACCORDING TO[NEC 690.47],[NEC TABLE 250.66], DC FOLLOWS:DC POSITIVE-RED(OR MARKED RED), DC NEGATIVE-GREY(OR MARKED GREY) U_ OF- 0 CL 2. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN#8 AWG AND SYSTEM GEC SIZED ACCORDING TO[NEC 250.166], MINIMUM#8AWG WHEN 11. POSITIVE GROUNDED SYSTEMS DC CONDUCTORS COLOR CODED: Z c >-- NO GREATER THAN#6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING INSULATED,#6AWG WHEN EXPOSED TO DAMAGE. DC POSITIVE-GREY(OR MARKED GREY), DC NEGATIVE-BLACK(OR MARKED BLACK) LU -2- co ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. 14. EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, 12.AC CONDUCTORS>4AWG COLOR CODED OR MARKED: N N U) 0 3. PV SYSTEM SHALL BE GROUNDED IN ACCORDANCE TO[NEC 250.21],[NEC TABLE EQUIPMENTS,AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN PHASE A OR L1-BLACK, PHASE B OR L2-RED, PHASE C OR L3-BLUE. NEUTRAL- Z - 1- 0 c 250.122], AND ALL METAL PARTS OR MODULE FRAMES ACCORDING TO[NEC ACCORDANCE WITH 250.134 OR 250.136(A)REGARDLESS OF VOLTAGE. WHITE/GRAY DRAWING BY 690.46]. 'USE-2 IS NOT INDOOR RATED BUT PV CABLE IS RATED THWN/THWN-2 AND MAY Carlin Johnson 4. MODULE SOURCE CIRCUITS SHALL BE GROUNDED IN ACCORDANCE TO[NEC WIRING&CONDUIT NOTES BE USED INSIDE 690.42]. 1.ALL CONDUIT SIZES AND TYPES,SHALL BE LISTED FOR ITS PURPOSE AND '"USE-2 IS AVAILABLE AS UV WHITE 5. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT APPROVED FOR THE SITE APPLICATIONS 13. IF CONDUIT DETERMINED TO BE RAN THROUGH ATTIC IN FIELD THEN CONDUIT WILL DATE THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDED CONDUCTOR 2.ALL PV CABLES AND HOMERUN WIRES BE TYPE USE-2,AND SINGLE-CONDUCTOR BE EITHER EMT, FMC,OR MC CABLE IF DC CURRENT COMPLYING WITH NEC 690.31, NEC November 9, 2018 TO ANOTHER MODULE. CABLE LISTED AND IDENTIFIED AS PV WIRE.TYPE TC-ER,OR EQUIVALENT; ROUTED TO 250.118(10). DISCONNECTING MEANS SHALL COMPLY WITH 690.13 AND 690.15 6. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTIONS POINTS SOURCE CIRCUIT COMBINER BOXES AS REQUIRED 14. CONDUIT RAN THROUGH ATTIC WILL BE AT LEAST 18"BELOW ROOF SURFACE PROJECT NUMBER IDENTIFIED IN THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 3.ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO[NEC COMPLYING WITH NEC 230.6(4)AND SECURED NO GREATER THAN 6'APART PER NEC 55564675 7. ENCLOSURES SHALL BE PROPERLY PREPARED WITH REMOVAL OF PAINT/FINISH 690.8] FOR MULTIPLE CONDUCTORS 330.30(B). AS APPROPRIATE WHEN GROUNDING EQUIPMENT WITH TERMINATION 4.ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE INSTALLED SHEET NAME GROUNDING LUGS. AT LEAST 7/8"ABOVE THE ROOF SURFACE AND DERATED ACCORDING TO[NEC TABLE ELEC. CALCS. 8. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,AND 310.15(B)(2)(a), NEC TABLE 310.15(B)(3)(a),&NEC 310.15(B)(3)(c)]. GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR DIRECT BURIAL. 5. EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2,90°C RATED,WET AND UV PAGE NUMBER REVISION STRANDED,9. GROUNDING BARE BONDING EXPOSEDUSED TO PROTECT WIRESHARP EDGES CONDUCTORS SHALL BE COPPER, SOLID OR LISTEDRATED UV RATED SPIRAL WRAP SHALL BE PV6 0 Intertek AUTHORIZATION TO MARK BLUE RAVEN This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) ° 1220 S.630 E STE 430 Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing AMERICAN FORK,UT 84003 Report. This authorization also applies to multiple listee model(s) identified on the con-elation page of the Listing } 800-377-4480 Report. i WWW.BLUERAVENSOLAR.COM 1 CONFIDENTIAL-THE INFORMATION This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may ben HEREIN CONTAINED SHALL NOT BE applied only at the location of the Party Authorized To Apply Mark. USED FOR THE BENEFIT OF ANYONE EXCEPT ,. ,..,., BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Applicant: Unirac, Inc Manufacturer: Jiaxing Pacific Energy Equipment Corp. PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION. EXCEPT IN CONNEC TION WITH THE No.8 Haiwan Ave SALE AND USE OF THE RESPECTIVE 1411 Broadway Blvd NE Hangzhou Bay Bdao New Area EQUIPMENT,WITHOUT THE Address: Albuquerque,NM 87102 Address: Haiyan Economic Development Area WRITTEN PERMISSION OF BLUERAVENSOLAR LLC, Jiaxing City,Zhejiang Province Country: USA Country: China O >- o D 5 Ili Klaus Nicolaedis Lili Zeng rn Z 0 Q ,r Contact: Contact: Q CC co U 0 N: Jason Mayfield George Huang t_ ZDrn Q (nr.,,, 505-462-2190 510-979-1920 ' to Phone: Phone: d 0 r Z 505-400-2949 650-799-7627 2 F- up I- LU co FAX: NA FAX: NA H O CO 0 Q 0 klaus.nicolaedis@unirac.com Izeng@ccmfg.com LU 0 0 Cr Email: asonm unirac.com Email' 0 1 @ george@ccmfg.com tY —i Party Authorized To Apply Mark: Same as Manufacturer a CO Report Issuing Office: Lake Forest,CA Control Number: 5003278 Authorized by: for Dean Davidson,Certification Manager i GUS osnita Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to M ark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client.Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this Authorization to Mark.Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety.Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark.Any further use of the Intertek name for the sale or advertisement of the tested material,product or service must first be approved in writing by Intertek.Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road,Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Standard(s): UL 2703 Issued: 2015/01/28 Ed: 1 Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels Photovoltaic Mounting System, Sun Frame Micro Rail- Installed Using Unirac Installation Manual, Rev Product: PUB2017FEB16 Brand Name: Unirac Models: Unirac SFM SHEET NAME DATA SHEET ATM for Report 102393982LAX-002 Page 1 of 2 ATM Issued:2-Mar-2017 PAGE NUMBER REVISION ED 16.3.15(1-Jul-16)Mandatory DS 0 I