Report (115)
INTELLIKNIGHT FIRE ALARM CONTROL PANEL "r-C 0\ , 00\U'. \` ¶ ( c \C v SILENT .EXISTING , LiliIlKnight° Model 5820XL KNIGHT Addressable Fire 0 8 Z018 Alarm Control System by Honeywell OFFICE "V The IntelliKnight System is the easy way to make the most of fire alarm technology. IntelliKnight 5820XL is the first fire alarm system to provide you with revolutionary value and performance in addressable sensing technology. The 5820XL FACP offers exclusive, built-in digital communication, distributed intelligent power, a modular design and an expanded, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the 5820XL system, or to locate your nearest source, please call 800-328-0103. Description 5820XL is an intelligent addressable fire alarm control panel 1.4 (FACP). The basic 5820XL system can be expanded by adding modules such as 5860 remote annunciator, 5815XL signalling • line circuit expander, 5824 serial/parallel printer interface ;� module (for printing system reports), and 5895XL intelligent power module. 5820XL supports SD or SK devices. 5820XL also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features • Built in support for 99 SK detectors and 99 SK modules, expandable to 396 SK detectors and 396 SK modules using System Sensor protocol = �� , • Built in support for 127 SD devices, expandable to 508 SD devices using the SD protocol. • Uses standard wire—no shielded or twisted pair required • Built-in digital communicator Model 5820XL • Central station reporting by point or by zone • Built-in synchronization for appliances from AMSECO®, • 6 amp power supply and maximum (An Gentex®, Faraday, System Sensor, and Wheelock® addition capacity of 35 amphoursrequired cabinet enclosure is required for • FlexputTM I/O circuits batteries in excess of 18 amp hours) • Supports Class B (Style 4) and Class A(Style 6) configuration • Programmable date setting for Daylight for SLC, SBUS, and Flexput circuits Saving Time • 13 pre-programmed output cadences (including ANSI-3.41) and 4 programmable outputs Installation • Built-in annunciator with 80-character LCD display The 5820XL can be surface or flush • RS-485 bus provides communication to system accessories mounted • Built-in RS-232 and USB interface for programming via PC • Built-in Form C trouble relay rated at 2.5 amps at 27.4 VDC Compatibility • Improvements in SKSS software deliver five times faster The 5820XL signal line circuit (SLC) uploads/downloads supports multiple device types of the same • Two built-in Form C programmable relays rated at 2.5 amps protocol: at 27.4 VDC • SK (System Sensor) • Plex-1 door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing • SD single button operation of the reset and silence functions You cannot mix SD and SK SLC devices on a FACP. INTELLIKNIGHT FIRE ALARM CONTROL PANEL IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Indicator Lights 5820XL features a 6 amp power supply required to start a new system. The General Alarm (Red): Flashes when in and maximum battery charging built-in keypad and 5860 remote alarm; solid when alarm silenced capacity of 35 amp hours.An additional annunciator give on-site access to all cabinet enclosure(PN RBB)is required programming.You can also program Supervisory(Yellow): Flashes when a for batteries in excess of 18 amp hours. remotely using the 5660 Silent Knight supervisory condition exists; solid when Flexput circuits on 5820XL control can Software Suite,which is Windows®- supervisory silenced be individually programmed to function based software. System Troubles(Yellow): Flashes as notification circuits, auxiliary power when a trouble condition exists; solid outputs, or initiation circuits that Built-In Digital Communicator when trouble silenced support both 2-and 4-wire smoke detectors. 5820XL features a built-in UL listed System Silenced (Yellow): On when an The 5820XL system operates on non digital communicator for remote alarm, trouble or supervisory condition reporting of system activity and system has been silenced but not yet cleared twisted, unshielded cable when wired programming.The communicator has in compliance with standard wiring the ability to seize two telephone lines System Power(Green): Flashes for AC practices as called out in the National to report alarms and troubles to a failure; solid when power systems are Electric Code 760-51 specifications for monitoring facility.The communicator normal power-limited fire protective signalling supervises two phone lines and will cables. No special wiring is required. System Application 5820XL provides 13 preset notification activate a trouble signal if a line failure cadencepatterns(includingANSI 3.41) is sustained for more than 45 seconds. 5820XL has one built-in signalling line Other communication features include: circuit(SLC)which supports multiple and four user programmable selections retry if communication fails, two phone devices dependent on protocol being for fire alarm notification. number capability, download phone used.Three additional loops can be Two programmable general purpose number capability and Touch-Tone or added usingthe 5815XL SLC Form C relay outputs are provided on rotary dialing.The communicator is expanders to increase overall capacity. 5820XL. compatible with SIA and Ademco Additionally, the IntelliKnight system Contact ID.The format is selectable by The 5820XL SLC loops support features a built-in walk test and auto- multiple device types, including: account number. programming. Its innovative, dead-front • Addressable photoelectric smoke cabinet design allows for flush or detector surface mounting. System maintenance • Addressable ionization smoke is easy to perform. detector , �` User Interface • Addressable heat sensor The 5820XL built-in annunciator with • Addressable duct smoke detector 80 character LCD display and large , • Contact module easy-to-use tactile touchpad can be • Relay output module used for system operation, programming and maintenance. It has • Addressable notification module five LEDs for alarm, supervisory, • Addressable beam detector(SK system trouble, system silenced and protocol only) system power. System operations • Addressable multi-criteria smoke include silencing alarms and troubles, Approvals detector(SK protocol only) resetting alarms and the display of NFPA 13, NFPA 15, NFPA 16, alarm troubles and memory.The NFPA 72: Central Station; Remote • Addressable multi modules (SK system's non-volatile event history protocol only) buffer stores 1000 events for viewing Signalling; Local Protective Signalling from the built-in or remote annunciator. Systems;Auxiliary Protected Premises The following advanced sensor Unit; &Water Deluge Releasing capabilities are available with 5820XL: System operation can be initiated with Service. Suitable for automatic, a mechanical firefighter's key ora valid manual, waterflow, sprinkler • Automatic drift compensation 4-to 7-digit operator's code. supervisory(DACT non-coded) • Maintenance alert Programming signalling services. • Built-in sensor test to comply with The IntelliKnight system offers several g y Other Approvals: UL Listed; NFPA 72 calibration testing options to simplify and speed up CSFM 7170-0559: 135; requirements The JumpStart®feature MEA 429-92-E Vol.VI; FM Approved p pproved minimizes programming IINTELLIKNIGHT FIRE ALARM CONTROL PANEL IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel IntelliKnight 5820XL adows Facility sed Addressable Fire Alarm System Management Softwareo. SK(System Sensor) Protocol Devices UUSndows Based Up/Download Software E T _.,.. . i , , Compatble CS -" 1 'r Receiver I- — tomation Ai , SoftwareInternet0. WOO 5820%L SK-2/2UD Connection UsorAlarre IP Communicator 5895XL i,ellla tiodu s --=` 3F t,C Raa+s —10- .r 4H,w• , !,..,,...t_ E.,ararlr Peel.7 5815XL 8 .-, 1Rs;=2�' SLC Loado� 5860 5824 ti Romotc Mnundetor f'rr[-s.%t3nw hfodule � J l hie-Mar„y-,"err) 1 4 -0. 6 Flexput UC Circuits _ 5815XL can be - SLC Fr rend, r ` F. or outputs c 6 Flexput”" m VO Circu es .. 5 uF ..can be inputs or outputs 'Si ' 1 e R 4 E V. OcareCdrobes lapssad WC: ±l P 1111rn, ,rr ,rnM I'.Ictrzs Y . 0II o SKdon SK-Monitor SK-Iso SK-Control-6 SK-Control 620006 SK-Acclimate SK-2onefi� Nddressado Adz wide Fault soletor Addressable SperoS J Sounder Mutcntena Erne In � Irx:.t„r.. Mora., M Dr-AD 11x`cuttr. R.r-teR a,. sulci.& hart,fnce 5860 Detoctcr r/OduO 11011..13 Modulo dotoctc, mod.lo remote Arnumeter , , 6 ,,'A vat l; _orr o� SK-Photo SK-Monitor-2 SK-telaymon-2 SK-Heat B224RB 13224BI B210LP SK-Photo-T =uA von tx Ad]ressatle SK-Heat-ROR RNayihlrrnra rv-renrc 5880 1ns Ad a,e [haute Dui siaiitor Sit Heat-HT Ease 3=e e LEE Duve,R 1-110t00E ate 3c[ne WT.',Rdats HEI k able Dor$ IN tNodufe Cetecta or, C — NM i1 it-I I -1 --i- � 5883 I 4 Reny lined',e N:1,ci.11e SK-Beam SK-Non-10 SK-Pull-DA SK-Duct SK-Mnimon SK-Relay-6 SK-Zone SK-Relay SK-Beare-T Adt,EsEII SK-Pull-6A A]axs-de Msi;or FpeyC0a30I A01—a, - Adtosa_tda r -ble Po eel, airlrassn•.- Du M dulo Mcdule Intenare R.4av 11,'17,•-r C',tPrto; Module F,,11 S1atan D,,,,,tMnrl.ru Medu.= 5865.4 or 5865.3 I ums 1 Use the 5880 to control up to 4�__, ( � ,I1(Wr 1 5883 Relay Interface Modules 1 INTELLIKNIGHT FIRE ALARM CONTROL PANEL IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Specifications S-BUS Accessories Miscellaneous Accessories Electrical 5860/R Remote Fire Annunciator 5660 Silent Knight Software Suite Primary AC: Features the same 80 character backlit (SKSS) 120 VRMS at 50/60 Hz, 2.5A or LCD display keypad and firefighter's User-friendly Windows software for 240 VRMS at 50/60 Hz, 1.4A keyswitch as the 5820XL. 5860 is gray remote programming of 5820XLs using Total Accessory Load: 6A @ 27.4 VDC, and 5860R is red. a PC. Upload and view panel account power-limited 5815XL Signal Line Circuit Expander information, event history, and detector Standby Current: 215 mA The SLC expander is used to add more status. Alarm Current: 385 mA addressable devices to the IntelliKnight 5670 Silent Knight Software Suite system. 5820XL supports three (SKSS) Flexput Circuits: 5815XL's. Each 5815XL can support 99 Powerful end-user facility management Six programmable circuits which can be SK detectors and 99 SK modules or software allows viewing of detector programmed individually as: 127 SD devices. status and event history via modem or Notification circuits: 3A @ 27.4 VDC 5895XL Intelligent Power Module direct connection. per circuit, power-limited Adds 6 amps of power, 6 Flexput I/O Plex-1 Auxiliary power circuits: 3A @ 27.4VDC circuits and 2 Form C relay circuits to a Dead front cabinet door with clear per circuit, power-limited 5820XL system. window to limit access to the FACP. Initiation Circuits: 100 mA @ 27.4VDC 5496 Intelligent Power Module RBB per circuit, power limited A 6 amp notification power expander Remote battery box accessory cabinet. that provides four power-limited notifi- Use if backup batteries are too large to Physical cation appliance circuit outputs. fit into FACP cabinet. Dimensions: Flush Mount Dimensions: 5880 LED/10 Module 16"W x 10" H x 6" D 14.5"W x 24.75"H x 3.9"DFeatures 40 LED outputs, 8 normally (406 mm W x 254 mm H x 152 mm D) (36.8 W x 62.9 H x 9.8 D cm ) open dry contact inputs, and one piezo SD505-DTS-K output. Remote test switch. Used with Overall Dimensions: 5865-3 and 5865-4 SD505-DUCTR. Provides remote key 16.2"W x 26.4"H x 4.2"DRemote LED Annunciator operated test function and annunciation (40.6 W x 67 H x 11.8 D cm) Features 30 programmable LED (15 of detector alarm. red and 15 yellow)outputs, and a piezo SD and SK Devices Weight: 28 lbs. (12.8 kg) sounder.The 5865-4 adds a silence See the specification sheets listed Color: Red and reset switch to the package. below for a complete listing of the SD Battery Charging Capacity: 7.0-35 AH 5883 Relay Board and SK devices. Features 10 general purpose Form C 53624 SD Devices Data Sheet Battery Size: 18 AH max allowed in relays. Used with 5880 module. 53623 SK Devices Data Sheet control panel cabinet. Larger capacity 5824 Serial/Parallel Printer batteries can be housed in RBB Interface Module accessory cabinet. Provides one parallel and one RS-232 serial port for connecting a printer to Telephone Requirements: the 5820XL. Use to print a real-time log FCC Part 15 and Part 68 approved of system events, detector status Type of Jack: RJ31X(two required) reports, and event history. Interfaces with building control system. SILENT This document is not intended to be used for installation purposes.We try to keep our KNIGHT product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice. Made in America For more information,contact Silent Knight 12 Clintonville Road,Northford,CT 06472 PN 350210 Rev H2 by Honeywell Phone:(203)484-7161,Fax:(203)484-7118.www.silentknight.com. ©2012 Honeywell International Inc. IntelliKnight&JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight INTELLIKNIGHT ACCESSORY tSILENT SK-Photo, SK-Photo-T KNIGHT and SK-PhotoR by Honeywell Intelligent Photoelectric Smoke Sensors The SK-Photo is a photoelectric smoke detector, the SK-Photo-T is a photoelectric smoke detector with thermal and SrK-PhotoR is a photoelectric detector with remote test capability. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight IntelliKnight Fire Alarm Control Panels (FACPs). For more information about the IntelliKnight system, or to locate your nearest source, please call 800-328-0103. Description • Optional remote LED annunciator (System Sensor®PN RA100Z) � ' a ill SK-Photo and SK-Photo-T are plug-in • Plug-in mounting provides ease of type smoke sensors that combine a installation404;-,1:-.,111h--7--?90,:i-1:1;-;-o0-21' � I � � photoelectric sensing chamber with �� �` addressable analogcommunications. • Tamper-proof feature available on -11 Point ID capability allows each mounting bases detector's address to be set with rotary • Listed for use in duct applications �ioo' address switches, providing exact • Rotary address switches for fast detector locations for selective installation maintenance when chamber • UL Listed contamination reaches unacceptable • FM Approved levels. SK-Photo and SK-Photo-T have a Specifications -g, unique optical sensing chamber that is Physical engineered to sense smoke produced Height: 2.0" (5.0 cm) SK-Photo (Base included) by a wide range of combustion Diameter:4.1" (10.4 cm) installed in sources. In the SK-Photo-T, dual B501 base Installation electronic thermistors add 135°F(57°C) thermal technology to maximize Electrical detection. Operating Voltage: 15-32 VDC The SK-Photo and SK Photo T plug Standby Current: into a compatible IntelliKnight-series The SK-PhotoR is a remote test detector base.The SK-PhotoR is a capable detector for use with the 300 pA @ 24 VDC Maximum remote test capable detector head DNR/DNRW duct smoke detector. (not Alarm Current: 6.5 mA @ 24 VDC max included within the DNR(W)duct included) (with LED on) smoke detector. Environmental Compatibility Operating Temperature l� y Features SK-Photo: 32°— 120°F(0°C—49°C) SK-Photo, and SK-Photo-T are • Sleek, low-profile design SK-Photo-T: 32°— 100°F(0°C—38°C) compatible with the following detector • Base included Humidity: 10%—93% non-condensing bases: Other Ratings B210LP 6" base (included) • Reliable analog communications for 9 B501 2 wire base trouble-free operation SK-Photo-T Thermal: Fixed B224RB Relay base • Age resistant polymer housing temperature set point 135°F(57°C) B224B1 Isolator base • Dual electronic thermistor design on Velocity: 0—4000 fpm (0—20 m/sec) B200SR Sounder base the SK-Photo-T The SK-Photo, SK-Photo-T, and SK- • Superior EMI resistance for reliability PhotoR are compatible with the • Simple field cleaning for code following IntelliKnight FACPs: compliance 5820XL • Variety of mounting options to meet 5820XL-EVS any application 5808 5700 • Dual LED indicators for 360°visibility 5600 (Rev 2.0 or higher) • Detector transmits signal to indicate maintenance is required INTELLIKNIGHT ACCESSORY Model SK-Photo, SK-Photo-T and SK-PhotoR Intelligent Photoelectric Smoke Sensors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent photoelectric smoke sensors Silent Knight SK-Photo or SK-Photo-T with thermal. The combination detector head, and twist-lock base, shall be UL listed and compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with SK-Photo or SK-Photo-T. Base shall be the appropriate twist-lock base part number B210LP (included). The PhotoR is a remote test capable detector for use with DNR(W) duct smoke detectors. (not included). The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SK-Photo shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. jive r N OUT MCompatible FACP RNLI f+ — RA100Z(Optional) rillIIII 111 IIII\ - E-Lil"1\ ....i. i I .iF ell .. litylip. awl VI 11111 i litf,„,, ‘. Niiii, II in i Class A Optional Wiring r Wiring SK-Series Detector Mounting Bases SILENTEl This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350118 Rev E subject to change without notice.For more information,contact Silent Knight ©2013 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford,CT 06472-1610 Phone: (800)328-0103, Fax:(203)484-7118.For Technical Support,Please call 800-446-6444. www.silentknight.com I s yr t C ; Power Supplies and Accessories E D wA R D EXISTING 23j, 'I Remote Booster . . Power Supplies ptit BPS6A, BPS1OA MEA 476-91-E .4,444 :41er Vol.13 UL 53424 7300-1657: 0229 Overview Standard Features The Booster Power Supply(BPS)is a UL 864,9th Edition listed • Allows for reliable filtered and regulated power to be installed power supply. It is a 24 Vdc filtered-regulated, and supervised where needed unit that can easily be configured to provide additional notification • Cost effective system expansion appliance circuits(NACs)or auxiliary power for Mass Notification/ • Emergency Communication(MNEC),as well as life safety,security, Provides for Genesis and Enhanced Integrity notification ap and access control applications. pliance synchronization • Supports coded output operation The BPS contains the circuitry to monitor and charge internal • • or external batteries.Its steel enclosure has room for up to two Self restoring overcurrent protection 10 ampere-hour batteries. For access control-only applications, • Multiple signal rates the BPS can support batteries totaling up to 65 ampere-hours in • Can be cascaded or controlled independently an external enclosure.The BPS has four Class B(convertible to • Easy field configuration two Class A)NACs.These can be activated in one or two groups from the BPS's unique dual input circuits. • On-board diagnostic LEDs identify wiring or internal faults The BPS is available in 6.5 or 10 ampere models. Each output • Standard EDWARDS keyed lockable steel cabinet with re- movable door circuit has a capacity of three amperes;total current draw cannot exceed the unit's rating. • 110 and 230 Vac models available • Accommodates 18 to 12 AWG wire sizes The BPS meets current UL requirements and is listed under the following standards: • Optional tamper switch Standard(CCN) Description • Dual battery charging rates UL864 9th edition(UO)X)Fire Alarm Systems • Optional earthquake hardening:OSHPD seismic pre-approval UL636(ANET,UEHX7) Holdup Alarm Units and Systems UL609(AOTX,AOTX7) Local Burglar Alarm Units and Systems for component Importance Factor 1.5 UL294(ALVY,UEHX7) Access Control Systems UL365(APAW,APAW7) Police Station Connected Burglar Alarm Units and Systems UL1076(APOU,APOU7) Proprietary Burglar Alarm System Units UL1610(AMCX) . Central Station Alarm Unit ULC-S527(UOXXC) Control Units,Fire Alarm(Canada) ULC-S303(AOTX7) Local Burglar Alarm Units and Systems(Canada) - C22.2 No.205 Signaling Equipment(Canada) Page f of 4 U A AT E85005-0125 Noi to be used for Insta([<U a Issue 1 Application Dimensions The BPS provides additional power and circuits for notification ap- pliances and other 24 Vdc loads. It is listed for indoor dry locations 1 D5 and can easily be installed where needed. Q 0 0 Top View Fault conditions are indicated on the on-board diagnostic LEDs, opening the BPS input sense circuit and the trouble relay(if t-D2-► -4 D3 ►) programmed).While this provides indication to the host system, A •••••••• I 1.•••the BPS can still be activated upon command.A separate ACFail contact is available on the BPS circuit board,which can be 04 D4—*0oprogrammed for trouble or AC Fail.There are seven on-board diagnostic LEDs:one for each NAC fault,one for battery fault,one m Front Viewo for ground fault,and one for AC power. a) • The unique dual-input activation circuits of the BPS can be acti- vated by any voltage from 6 to 45 VDC(filtered-regulated)or 11 O to 33 Vdc(full-wave rectified,unfiltered).The first input circuit can D1 D6 be configured to activate 1-4 of the four possible outputs.The v�second input circuit can be configured to control circuits 3 and 4. All knockouts mWhen outputs are configured for auxiliary operation,these circuits for 3/4 in conduitcan be configured to stay on or automatically deactivate 30 sec- (1.9 cm) o conds after AC power is lost.This feature makes these circuits ideal 0 for door holder applications.The BPS also has a separate 200 mA 24 Vdc output that can be used to power internal activation �■ 11 i ...... modules. Dl D2 i D3 t'1'�D4 D5 D6 BPS NACs can be configured for a 3-3-3 temporal or continuous si output.California temporal rate outputs are also available on cer- 17.0 in 3.5 in 13.0 in 6.5 in 3.375 in 12.0 in tain models.This makes the BPS ideal for applications requiring (43.2 cm) (8.9 cm) (33.0 cm) (16.5 cm) (8.6 cm) (30.4 cm) signaling rates that are not available from the main system. In addition to the internally generated signal rates,the BPS can also be configured to follow the coded signal rate of the main Wire routing Power-limited system NACs.This allows for the seamless expansion of existing wiring area NACs. The BPS enclosure has mounting brackets for up to three Signa- ■ ■ ture modules to the right of the circuit board. - O e o Engineering Specification I [2] _ Supply,where needed, EDWARDS BPS Series Booster Power ❑ e l l o O o Supplies(BPS)that are interconnected to and supervised by the ;; main system.The BPS shall function as a stand-alone auxiliary •0- 0 O '■ ■ power supply with its own fully supervised battery compliment. •■--� ;;[3] _■ o The BPS battery compliment shall be sized to match the require- Route AC supply - •• , •^° H o ments of the main system.The BPS shall be capable of supervis- through these • =="' ing and charging batteries having the saponify of 24 ampere-hours -- knockouts only i ® ®■ for Mass Notification/Emergency Communication(MNEC),life (Nonpower-limited —' .111\ A' 11111 safety and security applications,and the capacity of 65 ampere------ and supervised) Battery wiring(nonpower- hours for access control applications. o limited and supervised) o «The BPS shall be capable of installation for a seismic corn- Battery Battery ponent Importance Factor of 1.5.»The BPS shall provide a minimum of four independent,fully supervised Class B circuits _ that can be field configurable for notification appliance circuits or auxiliary 24 Vdc power circuits. BPS NACs shall be convertible to a minimum of two Class A NACs. Each BPS output circuit shall be Notes rated at 3 amperes at 24 Vdc. Each output circuit shall be pro- 1. Maintain 1/4-inch(6 mm)spacing between power-limited and nonpower-limited vided with automatically restoring overcurrent protection.The BPS wiring or use type FPL,FPLR,or FPLP cable per NEC. [2] Power-limited and supervised when not configured as auxiliary power.Non- shall be operable from the main system NAC and/or EDWARDS supervised when configured as auxiliary power. Signature Series control modules. BPS NACs shall be configurable [3] Source must be power-limited.Source determines supervision. for continuous,3-3-3 temporal or optionally, California rate. Fault 4. When using larger batteries,make sure to position the battery terminals towards conditions on the BPS shall not impede operation of main sys- the door. tern NAC.The BPS shall be provided with ground fault detection circuitry and a separate AC fail relay. Page2of4 DATA SHEET E85005-0125 ^ to So used for inuiallatiun ourposu. Issue 1 Typical Wiring Single or cascaded booster NAC Circuit >To next signaling g NAC Circuit ` / device,booster,or anywhere on a notification appliance circuit V >EOL resistor ExistingNAC end-of-line resistors are not required to be CO >NAC output#1 q Fire Alarm N M >NAC output#2 installed at the booster's terminals.This allows multiple Control Panel g3 N >NAC output#3 boosters to be driven from a single NAC circuit without the s >NAC output#4 need for special configurations. a Booster Power Supply Configuring the Booster for Multiple CC1(S) modules using the AC Power Fail delay operation* BPS's sense inputs TB1 Notification appliance circuit(NAC) TBI Notification appliance circuit(NAC) NAC1/+ a UL listed NAC1/ + qt UL listed AUX1 - V) C p1 EOL 15 k4 AUX1 - O asigiEOL 15 KW AUX2NAC2/ - (g) Notification appliance circuit(NAC) AUX2/ - Notification appliance circuit(NAC) NAC3/ a_ listed NAC3/ + a Ella, EOL - am E AUX3 � EOLL115 kit AUX3 - aEOLLUL 15 KW NAC4/+ a NAC4/ + (>J AUX4 - 0 AUX4 - 4 200 mAAUX v) 4 + 200 mAAUX N aJ• Continuous m aJ - Continuous m a IN1�J + INli + Sense 1 COM 10- Sense 1 COM IEOL 47 K OUT Ia + OUT I�)� INI�1 7 FE- I INla + Sense 2 COM I a EOL 47 kit 10 9 i Sense 2 COM I a EOL 47 K OUT 0) CC1(S)module[1][3] OUT a NONO a1 �_ n 1 ki + n Trouble COMM 0 8 7 6 5 0 4 0 2 1 Trouble COM a NC a uuui'i■',,.„1.v..I.1... NC a 109 109 TB2o +- --+- T62 CC1(S)module CC1(S)module 9•C• • Data in from Data out to 0 8765 4321 8765 04321 previous device — next device •jail*0 : o of module[4] = il* ,I I I I i7, 0 0 or Signature +-+- {11 +-+- [1 controller 0 0 0,151 Data in from previous +— [. Data out to The Booster supports AC Power fail delay [31 device or Signature next device of three hours via its trouble contact when controller dip switch SW2-6 is on.All other troubles are reported to supervising module or panel without delay via Sense inputs. Security and access BPS TB1 24 V 12 V NAC1/+I l Security Security EOL . . .i 24DC12 1111. Security AUX1 [ 1 device device NAC2/+I J . device AUX2 -[3] NAC3/+[J] AUX3 -L J NAC4/ +[ 1 AUX4 -E 31 Control panel BPS[1] Card reader Card reader Card reader controller controller controller + — -F -F ♦ — + — AT AT To next device [1] Disable the BPS's ground fault jumper(JP3) or end Page 3 of 4 E85005-0125 s Issue 1 . ...�__ Specifications Model 6.5 amp Booster 10 amp Booster 9 fj & AC Line Voltage 120VAC or 220-240VAC 50/60Hz1-120VAC or 220-240VAC 50/60Hz 390 watts 580 watts :,:c` -,-°ihrIL)'-_N MAN Y':= ' Notification Appliance 3.0A max.per circuit @ 24Vdc 3.0A max.per circuit @ 24Vdc Circuit Ratings nominal 6.5A max total all NACs nominal 10A max total all NACs Contact us... Email: edwards.fire@fs.utc.com Trouble Relay 2 Amps @ 30Vdc Web: edwards-flre.com • Auxiliary Outputs Four configurable outputs replace NACs 1,2,3 or 4. as auxiliary outputs and 200 mA dedicated auxiliary.(See note 2.) 1016 Corporate Park Drive Mebane,NC 27302 Input Current 3mA @ 12Vdc,6mA @ 24Vdc (from an existing NAC) EDWARDS is a registered mark in the Booster Internal 70mA+35 mA for each circuit set to AUX United States and other countries. Supervisory Current ©2018 United Technologies Corporation. Booster Internal Alarm 270mA All rights reserved. Current Signature Mounting Accomodates three two-gang modules. Space Maximum Battery Size 10 Amp Hours(2 of 12V1 OA)in cabinet up to 24 Amp hours with ex- ternal battery cabinet for fire and security applications;up to 65 Amp hours for access control applications in external battery box. Terminal Wire Gauge 18-12 AWG Relative Humidity 0 to 93%non condensing @ 32°C Temperature Rating 32°to 120°F(0°to 49°C) NAC Wiring Styles Class A or Class B Output Signal Rates Continuous,California rate,3-3-3 temporal, or follow installed panel's NAC.(See note 1.) Ground Fault Detection Enable or Disable via jumper Agency Listings UL,ULC,CSFM 1. Model BPS*CAA provides selection for California rate,in place of temporal. 2. Maximum of 8 Amps can be used for auxiliary output. Ordering Information Catalog Description _ liatiliAlli ' , '�v Number 1, ®r a1,= BPS6A 6.5 Amp Booster Power Supply 13(5.9) BPS6AC 6.5 Amp Booster Power Supply(ULC) 13(5.9) BPS6A/230 6.5 Amp Booster Power Supply(220V) 13(5.9) BPS6CAA 6.5 Amp Booster Power Supply with California rate 13(5.9) BPS10A 10 Amp Booster Power Supply 13(5.9) BPS1OAC 10 Amp Booster Power Supply(ULC) 13(5.9) BPS10/V230 10 Amp Booster Power Supply(220V) 13(5.9) BPS1OCAA 10 Amp Booster Power Supply with California rate 13(5.9) 1. Requires installation of sepa- rate battery cabinet. Related Equipment h(i(CIAbig 2. BPS su pports batteries greater 12V6A5 7.2 Amp Hour Battery,two required 3.4(1.6) than 24 Amp hours for access 12V1 OA 10 Amp Hour Battery,two required 9.5(4.3) control applications only. 3. For earthquake anchorage, 3TAMP Tamper switch including detailed mounting BC 1 EQ Seismic Kit for BC-1. Order BC-1 separately.See note 3. weights and center of gravity BPSEQ Seismic kit for BPS6A or BPS10 Booster Power Supplies.See detail,refer to Seismic Applica- note 3 tion Guide 3101676. Approval BC-1 Battery Cabinet(up to 2-40 Amp Hour Batteries) 58(26.4) of panel anchorage to site structure may require local BC 2 BatteryCabinet(up to 2 17 Amp Hour Batteries) 19(8.6) AHJ,structural or civil engineer 12 17A 18 Amp Hour Battery,two required(see note 1) 13(5.9) review. 12V24A 24 Amp Hour Battery,two required(see note 1) 20(9.07) 12V40A 40 Amp Hour Battery,two required(see notes 1,2) I 32(14.5) 12V50A 50 Amp Hour Battery,two required(see notes 1,2) 40(18.14) 12V65A 65 Amp Hour Battery,two required(see notes 1,2) 49(22.2) N Page 4 of 4 DATA SHEET E85005-0125 iz J . . lu be sub for nsr allai ui pub - -. Issue t I 1 Strobes, Horns,Bells,Chimes Kidde fa,,United Technologies Technology that saves lives Field CConfigurable Ceiling S � Genesis Series m6. k 7.7 O Fc 41) o MEA C E 712216570 : 9 S5389 Overview Standard Features Genesis life safety and mass notification/emergency communica- • Field configurable—no need to remove the device! tions(ECS/MNS)ceiling strobes are small,compact,and attractive — 15/30/75/95 cd and 95/115/150/177 cd clear strobe lens visible emergency signaling devices. Protruding no more than 1.6" models available (41 mm)from the ceiling,Genesis strobes blend with any decor. — Switch settings remain visible even after the unit is installed Thanks to patented breakthrough technology, Kidde Genesis • ECS/MNS models available strobes do not require bulky specular reflectors and lenses. — Amber and blue lens models available. Instead,an exclusive cavity design conditions light to produce See Ordering Information for details. a highly controlled distribution pattern. Significant development • Unique low-profile design efforts employing this new technology have given rise to a new — 30 per cent slimmer profile than comparable signals benchmark in strobe performance—FuIlLight technology. — Attractive appearance FuIlLight strobe technology produces a smooth light distribution — No visible mounting screws pattern without the spikes and voids characteristic of specular — Available with white or red housings reflectors.This ensures the entire coverage area receives consis- • Easy to install tent illumination from the strobe flash.As a result, Genesis strobes — Fits all standard 4"square electrical boxes with plenty of with FuIlLight technology go well beyond the minimum UL-required room behind the signal for extra wire—no extension ring or "cross"pattern,significantly exceeding UL-1971 and ULC-S526 trim plate needed light distribution requirements. — #18 to#12 AWG terminals—ideal for long runs or existing wiring Depending on the model,clear lens Genesis ceiling strobes fea- • Unparalleled performance ture 15 to 95,or 95 to 177 candela output(see ordering informa- — Exclusive FullLight strobe technology produces the industry's tion),which is selectable with a conveniently-located switch.The most even light distribution candela output setting remains clearly visible even after final instal- — Precision timing electronics meet tough synchronizing lation,yet it is locked in place to prevent unauthorized movement standards for strobes after installation. — Low current draw minimizes system overhead Genesis ECS/MNS appliances offer emergency signaling with • Approved for public and private mode applications clear amber or blue lenses.They are ideal for applications that re- — UL 1971-listed as signaling devices for the hearing impaired quire differentiation between life safety and mass notification alerts. — UL 1638-listed as protective visual signaling appliances — UUULC listed for ceiling or wall use Page 1 of 4 )ATA S K85001-0557 u>=€3 €r>a rrr, onr,< Issue 2 Application Dimensions Genesis strobes are UL 1971 or 1638 listed for indoor use.Prevailing 6.8 dia. codes require strobes to be used where ambient noise conditions (173 mm) exceed specified levels,where occupants use hearing protection, T and in areas of public accommodation.Consult with your Authority 1.0° Having Jurisdiction for details. 1d. (25 mm) All Genesis strobes exceed UL synchronization requirements 0.60'(15+m) (within 10 milliseconds over a two-hour period)when used with a synchronization source.Synchronization for multiple strobe lights in a single field of view is required. ECS/MNS Applications Genesis ECS/MNS appliances bring the same high-performance life Light output (effective cd) safety features and unobtrusive design to mass notification applica- Percent of UL rating versus angle tions.Available as standard units with clear,amber or blue lenses with optional ALERT markings,they are ideal for applications that — Percentage of rated output — 120 110 too g0 a0 70 60 50 40 30 20 10 0 10 20 30 40 50 60 70 80 90 100 110 120 90° require differentiation between life safety and ECS/MNS signals. g _� Units are also available(special order)with red or green lenses. IP �i, i IC° Installation All models are intended for indoor applications only.Strobes �0 � ri'�' h'I� t" = � c I , i mount to any flush North-American 4"square electrical box, 21/8" �r.i - (54 mm)deep. -05 ,yup 1i,, '61. a5° Genesis ceiling strobes simply unlatch and twist to open.This -sow 30 gains access to mounting screws and the selectable candela 5 --,- 5 switch.The shallow depth of Genesis devices leaves ample room ----Angle—� behind the signal for extra wiring.Once installed with the cover in Ho zonal and vertical outputs reflect the same pattern. place, no mounting screws are visible. (---3:„? . ? 0 o O o° ("b' \ Field Configuration o Q � .r Depending on the model,Genesis ceiling 0. 6 ` � ..� speaker-strobes have multi-candela output Candela switch / .� n (see ordering information).The outputi r--- &77- 4:0 setting is changed by simply opening the device and sliding the switch to the desired setting. The strobe does not have to be V— removed to change the output setting. J' �° The setting remains visible through a small \ Indicator window on the front of the device after the cover is closed. Wiring Field wiring terminals accommodate#18 to#12 AWG(0.75 mm2 WARNING:These devices will not operate without electrical power.As fires frequently to 2.5 mm2)wiring.Strobes are interconnected with a single pair ofcause power interruptions,we suggest you discuss further safeguards with your local fire protection specialist. wires as shown below. To listed uIuuIIIIIuuuuuuu1iI To next fire alarm appliance, control I 03 di di end-of-line panel or return to control equipment 0 vv Page 2 of 4 K85001-0557 ,.._ aloe p,ui t;s's. Issue 2 Current Draw Light output switch settings for UL 1971 listed models are selectable by numeric candela value. ECS/MNS appliances are selectable by A, B, C,or D designations. Standard output models(mA) High Output models(mA) UL "15"or ,D„ "30"or 'C„ "75„or"B" "95"or"A" "95"or"D" "115„or�,C>, = "150„or"B" "177"or"A" Rating RMS RMS ( RMS RMS RMS i RMS RMS RMS 16 Vdc 109 151 281 318 330 392 502 565 16 Vfwr 131 194 379 437 432 518 643 693 Standard output models(mA) High output models(mA) Typical i "15"or 'D" "30"or"C" 1 "75°or"B" "95 or"A„ "95"or"D" : "115"or"C" , "150"or"B" "177„or"A" Current ,RMS RMS RMS RMS RMS RMS RMS RMS 16 Vdc 94 140 273 325 333 392 499 551 20 Vdc 74 108 205 244 259 303 378 429 24 Vdc 63 90 168 194 212 245 306 342 33 Vdc 48 70 124 139 155 180 211 236 16 Vfwr 126 187 368 403 484 570 673 724 20 Vfwr 108 156 281 333 380 438 537 604 24 Vfwr 97 139 240 270 318 361 434 484 33 Vfwr 89 119 197 214 245 269 308 338 Light Output Standard output models High output models Switch Settings(candela) Switch Settings(candela)_ Lens Listings Lens Listings color Standard Setting Setting Setting Setting color Standard Setting Setting Setting Setting A B C Q A B C D Clear UL 1971 95 cd 75 cd 30 cd 15 cd Clear UL 1971 177 cd 150 cd 115 cd 95 cd Amber UL 1638 82 cd 65 cd 26 cd 13 cd Amber UL 1638 155 cd 130 cd 100 cd 82 cd Blue UL 1638 40 cd 31 cd 12 cd 6 cd Blue UL 1638 80 cd 78 cd 59 cd 48 cd Specifications Housing Textured UV stabilized,color impregnated engineered plastic.Exceeds 94V-0 UL flammability rating.Red and white models available. Lens Optical grade polycarbonate(clear). Mounting Flush mount to North American 4-inch square electrical box,2-1/8(54 mm)inches deep. No extension ring required.Suitable for indoor wall or ceiling applications. Wire Connections Screw terminals:#18 to#12 AWG(0.75 mm2 to 2.5 mm2)wire size. Operating Voltage Regulated 16 to 33 Vdc, 16 to 33 Vfwr. Operating Indoor:32-120°F(0-49°C)ambient temperature;0-93%relative humidity. environment Agency listings/ Meets or exceeds year 2004 UL requirements for standards UL1638 and UL1971 and Canadian requirements for standards approvals CAN/ULC S526-02 and CAN/ULC S524-01.All models comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule.CSFM,MEA, FM. Strobe output rating Clear: UL 1971,UL 1638,ULC S526:selectable 15/30/75/95 cd(GC-VM)and 95/115/150/177 cd(GC-VMH) Amber: CAN/CSA-C22.2 No.205,CAN/ULC-S526,UL 1638:selectable 13/26/65/82 cd(GCW*-VMA),82/100/130/155 cd(GCW`-VMHA) Blue: CAN/CSA-C22.2 No.205,CAN/ULC-S526,UL 1638:selectable 6/12/31/40 cd(GCW°-VMB),48/59/78/80 ed(GCW'-VMHB) Strobe operating GC-VM series strobes:non-coded,filtered 16-33 Vdc voltage or unfiltered 16-33 Vdc FWR. Strobe flash rate GC-VM series strobes:one flash per second synchronized with optional EG1 M Genesis Signal Master indefinitely within 10 milliseconds.Temporal setting(private mode only):synchronized to temporal output of Genesis audible signals on same circuit. Synchronization Meets or exceeds UL 1971 requirements.Maximum allowed resistance between any two devices is 20 Ohms. Refer to specifications for the synchronization control module,this strobe,and the control panel to determine allowed wire resistance. Synchronization GSA-CC1S,GSA-MCC1S,SIGA-CC2A,GSA-MCC2A,EG1M-RM,MIRBPS6A,MIRBPS1OA,APS6A,APS10A,VS Series, Sources Fireshield Plus 5 and 10 zone. Page 3 of 4 )AT, H F E r K85001-0557 N,,l it, b0�,£a<. ;. m,,1 ,, , ist:r, ,_,. Issue 2 „ Ordering Information �1Kinds Light output switch settings for UL 1971 listed models are selectable by numeric candela value. Yi unYeA„n.omv,es -� ECS/MNS appliances are selectable by A, B, C,or D designations. Technology that saves lives Model [ Housing 1 Marking ; Lens Strobe Ship Wt. Contact us... Life safety Appliances(c/w running man icon screen printed on housing) Email: kidde.fire@fs.utc.com GC-VM White None Web: kidde.com/engineeredsystemsSelectable GCF-VM White "FIRE” 15,30,75,or 95 cd 1.8 lb. 1016 Corporate Park Drive GCFR-VM Red "FIRE” Clear (0.82 kg.) Mebane,NC 27302 —GC-VMH White None Selectable high output Kidde is a registered mark in the United States GCF-VMH White "FIRE" 95, 115,150, or 177 cd and other countries. ©2018 Walter Kidde Portable Equipment. ECS/MNS Appliances(no running man icon on housing) All rights reserved. GCWA-VMA Amber GCWA-VMC "Alert" Clear GCWN-VMA Amber Selectable A,B,C,D GCWN-VMB None Blue GCWN-VMC Clear 1.8 lb. White GCWA-VMHA Amber (0.82 kg.) GCWA-VMHC Alert Clear GCWN-VMHA Selectable high output A,B,CorD GCWN-VMBH None GCWN-VMHC Clear t: 4 Page 4 of 4 K85001-0557 P a3€€3r, pulp,say, Issue2 11 :: ,,i [, Strobes, Horns,Bells,Chimes • ottlreii- 1 e Orvec Technology that saves lives FI e l dConfigurable ..._. One or more patents pending. Ceiling Hor ,,,„„„„. .;-, . , P _..... Strobes __ . °�� .. .• _ ,,, ,N r Genesis Series 4Dij' O MEA FC"Ur:0257: S Overview Standard Features Genesis ceiling horn-strobes are small,compact,and attractive • Field configurable—no need to remove the device audible-visible emergency signaling devices. Protruding no more — 15/30/75/95 cd and 95/115/150/177 cd models available than 1.6"(41 mm), Genesis horn-strobes blend with any decor. — Switch settings remain visible even after the unit is installed Thanks to patented breakthrough technology, Kidde Genesis — Low/high dB settings strobes do not require bulky specular reflectors and lenses. • Unique low-profile design Instead, an exclusive cavity design conditions light to produce — 30 per cent slimmer profile than comparable signals a highly controlled distribution pattern.Significant development — No visible mounting screws efforts employing this new technology have given rise to a new — Available with white or red housings benchmark in strobe performance—FullLight technology. • Easy to install FullLight strobe technology produces a smooth light distribution — Fits all standard 4"square electrical boxes with plenty of pattern without the spikes and voids characteristic of specular room behind the signal for extra wire—no extension ring or reflectors.This ensures the entire coverage area receives consis- trim plate needed tent illumination from the strobe flash.As a result,Genesis strobes — Pre-assembled with captive hardware—no loose pieces with FullLight technology go well beyond the minimum UL-required — #18 to#12 AWG terminals—ideal for long runs or existing "cross"pattern. wiring Depending on the model,Genesis horn-strobes feature 15 to 95, • Unparalleled performance or 95 to 177 candela output(see ordering information),which is — Exclusive FullLight strobe technology produces the industry's selectable with a conveniently-located switch on the front of the most even light distribution device.The candela output setting is clearly visible even after final — Single high-efficiency microprocessor controls installation,yet it remains locked in place to prevent unauthorized both horn and strobe movement after installation. — Low current draw minimizes system overhead — Independent horn control provided over a single Genesis horn-strobes feature textured housings in architecturally neu- pair of wires tral white or eye-catching fire alarm red.An ingenious iconographic — Highly regulated in-rush current allows the maximum symbol indicates the purpose of the device.This universal symbol number of strobes on a circuit is code-compliant and is easily recognized by all building occu- — 100 dB peak—multiple frequency tone improves pants regardless of what language they speak. Models with"FIRE" wall penetration markings are also available. Page 1 of 4 K85001-0559 Issue I Application Installation and Mounting Genesis strobes are UL 1971-listed for use indoors as ceiling-or All models are intended for indoor wall or ceiling applications wall-mounted public-mode notification appliances for the hearing only. Horn-strobes mount to any flush North-American 4"square impaired. Prevailing codes require strobes to be used where ambi- electrical box. ent noise conditions exceed 105 dBA(87dBA in Canada), where occupants use hearing protection,and in areas of public accom- o• modation as defined in the Americans with Disabilities Act(see O 0 O application notes-USA). O' o Combination horn-strobe signals must be installed in accordance ' I// 'i with guidelines established for strobe devices. , . �/ � 100,' Strobes Genesis strobes are UL 1971-listed for use indoors as ceiling-or o wall-mounted public-mode notification appliances for the hearing impaired.Prevailing codes require strobes to be used where ambi- ent noise conditions exceed specified levels,where occupants use hearing protection,and in areas of public accommodation. Genesis ceiling horn strobes simply unlatch and twist to open. Consult with your Authority Having Jurisdiction for details. This gains access to mounting screws and the selectable candela switch.The shallow depth of Genesis devices leaves ample room All Genesis strobes exceed UL synchronization requirements behind the signal for extra wiring.Once installed with the cover in (within 10 milliseconds other over a two-hour period)when used place, no mounting screws are visible. with a synchronization source. Synchronization is important in order to avoid epileptic sensitivity. Kidde recommends that these fire alarm horn-strobes always be installed in accordance with the latest recognized edition of NOTE:The flash intensity of some visible signals may not be adequate national and local fire alarm codes. to alert or waken occupants in the protected area. Research indicates that the intensity of strobe needed to awaken 90%of sleeping persons is Field Configuration approximately 100 cd.Kidde recommends that strobes in sleeping rooms Depending on the model,Genesis horn-strobes may be set for 15 be rated at at least 110 cd. to 95,or 95 to 177 candela output(see ordering information).The WARNING:These devices will not operate without electrical power.As output setting is changed by simply opening the device and sliding fires frequently cause power interruptions, further safeguards such as the switch to the desired setting.The horn-strobe does not have backup power supplies may be required. to be removed to change the output setting.The setting remains visible through a small window on the front of the device after the cover is closed. Horns The horn-strobe comes factory set for high dB output. Low dB Genesis horn output reaches as high as 99 dB(peak)and output may be selected by cutting a jumper on the circuit board. features a unique multiple frequency tone that results in excel This reduces the output by about 5 dB. lent wall penetration and an unmistakable warning of danger.All models may be configured for either coded or non-coded signal circuits.They can also be set for low dB output with a jumper cut that reduces horn output by about 5 dB. Wiring The suggested sound pressure level for each signaling zone used Field wiring terminals accommodate#18 to#12 AWG(0.75 mm2 with alert or alarm signals is at least 15 dB above the average ambient to 2.5 mm2)wiring.Horn/strobes are interconnected with a single sound level,or 5 dB above the maximum sound level having a duration pair of wires as shown below. of at least 60 seconds,whichever is greater,measured 5 feet(1.5 m) above the floor.The average ambient sound level is,A-weighted sound Q+ pressure measured over a 24-hour period. __._.. k ` Tonext Doubling the distance from the signal to the ear will theoretically y appliance, result in a 6 dB reduction of the received soundpressure level. Polarity shown in .. .� end-of-line alarm condition F.©, ► �i©' or return to The actual effect depends on the acoustic properties of materials F. PAra control in the space. A 3 dBA difference represents a barely noticeable ArA. CEJ equipment change in volume. ONote:Strobes must have continuous voltage. Dimensions 6.8"dia. (173 mm) YAP t 1.0" . iy0' J(25m m) 0.60"(15 mm) Page 2 of 4 K85001-0559 Issue 1 Current Draw EGC-HDVM Temporal Horn-strobe:High dB Setting EGC-HDVMH High cd Temporal Horn-strobe:High dB Setting UL 15 cd 30 cd 75 cd 95 cd 95 cd 115 cd 150 cd 177 cd Rating RMS RMS RMS RMS RMS RMS RMS RMS 16 Vdc 147 190 316 372 341 399 506 570 16 Vfwr 189 253 417 451 487 578 670 711 EGC-HDVM Temporal Horn-strobe:High dB Setting EGC-HDVMH High cd Temporal Horn-strobe:High dB Setting Typical 15 cd 30 cd 75 cd 95 cd 95 cd 115 cd 150 cd 177 cd Current RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean 16 Vdc 111 95 152 143 281 276 333 328 324 322 377 374 477 474 554 551 20 Vdc 91 80 124 117 219 214 257 251 258 256 299 296 369 366 417 414 24 Vdc 80 71 108 101 185 180 212 207 220 217 252 249 304 301 341 338 33 Vdc 69 62 89 84 144 140 160 156 172 169 188 185 223 220 244 241 16 Vfwr 153 81 218 123 388 240 420 268 463 265 535 312 665 400 718 442 20 Vfwr 141 70 190 100 325 188 378 219 392 211 439 240 517 287 587 334 24 Vfwr 135 64 176 90 280 154 310 180 346 179 382 212 458 246 498 271 33 Vfwr 139 61 167 80 241 122 254 133 296 142 323 152 358 178 387 194 EGC-HDVM Temporal Horn-strobe:Low dB Setting EGC-HDVMH High cd Temporal Horn-strobe:Low dB Setting Typical 15 cd 30 cd 75 cd 95 cd 95 cd 115 cd 150 cd 177 cd Current RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean 16 Vdc 108 91 149 139 275 269 327 322 317 315 378 376 480 477 544 542 20 Vdc 87 75 120 113 214 209 250 245 252 250 292 290 364 362 414 411 24 Vdc 76 66 103 97 180 175 205 201 212 211 245 243 297 295 334 332 33 Vdc 64 57 85 80 138 135 153 150 159 157 181 179 215 213 234 232 16 Vfwr 141 76 204 118 384 239 418 265 461 265 521 305 656 396 705 432 20 Vfwr 127 65 176 95 312 181 371 214 381 208 437 242 508 285 576 326 24 Vfwr 118 60 162 82 262 149 301 171 335 172 370 195 440 235 485 264 33 Vfwr 127 56 155 73 229 118 249 129 285 134 308 149 349 169 373 186 Notes and Comments 1. Current values are shown in mA. 2. UL Nameplate Rating can vary from Typical Current due to measurement methods and instruments used. 3. Kidde recommends using the Typical Current for system design including NAC and Power Supply loading and voltage drop calculations. 4. Use the Vdc RMS current ratings for filtered power supply and battery AH calculations.Use the Vfwr RMS current ratings for unfiltered power supply calculations. 5. Fuses,circuit breakers and other overcurrent protection devices are typically rated for current in RMS values.Most of these devices operate based upon the heating affect of the current flowing through the device.The RMS current(not the mean current)determines the heating affect and therefore,the trip and hold threshold for those devices. 6. Our industry has used'mean'currents over the years. However,UL will direct the industry to use the 2004 RMS values in the future. dBA output Light output - (effective cd) High dB UL464 Average Peak g Percent of UL rating versus angle Setting Temporal Steady Temporal/ Temporal/ Per CentoraRelin9 Steady Steady 120 110 100 90 80 70 60 50 40 30 20 10 0 10 20 30 40 50 60 70 80 90 100 110 120 16 Vdc 79.8 83.2 90.6 93.6 24 Vdc 83.3 85.4 93.6 96.6 33 Vdc 85 87.8 95.7 98.7 as .'j, 7s UL464 Average Peak Law dB Temporal/ Temporal/ .6o° so° Setting Temporal Steady Steady Steady 16 Vdc 75 79.3 86.3 88.7 -45 9JJJP'45° 24 Vdc 78 83 88.8 92.4 3 33 Vdc 80.9 I 85.9 91.8 , 95.1 so me o Notes 1.All values shown are dBA measured at 10 feet(3.01m);2.UL464 values measured in reverberation room;3.Average and Peak values are measured in anechoic cham- ber. Page 3 of 4 ,,mm , K85001-0559 F_ _ °„>> Issue 1 Specifications ,,oKidde Housing Textured UV stabilized,color impregnated engineered plastic.Exceeds 94V- 0 UL flammability rating.Red and white models available. Lens Optical grade polycarbonate(clear) Technology that saves lives Mounting North-American 4"square box,2 1/8"(54 mm)deep(indoor wall or ceiling applications only). Contact us... Wire connections Screw terminals:single input for both horn and strobe.#18 to#12 AWG(0.75 mm2 to 2.5 mm2)wire size Email: kidde.fire@fs.utc.com Operating environment Indoor:32-120°F(0-49°C)ambient temperature.93%relative humidity Web: kidde.com/engineeredsystems Meets or exceeds ULC-S525&ULC-S526,year 2004 UL 1016 Corporate Park Drive requirements for standards UL1638 and UL1971,and complies Mebane,NC 27302 Agency listings/approvals with UL1480.All horn-strobes comply with ADA Code of Federal Kidde is a registered mark in the United States Regulation Chapter 28 Part 36 Final Rule.CSFM, MEA.FM pending. and other countries. EGC-HDVM series temporal-tone horn-strobes:non-coded,filtered ©2018 Walter Kdde Portable Equipment. Operating voltage 16-33 Vdc or unfiltered 16-33 Vdc FWR (or coded(audible NAC only) All rights reserved. when used with optional EG1 M Genesis Signal Master) Strobe output rating UL 1971,UL 1638,ULC S526:selectable 15/30/75/95 cd(EGC- � HDVM)and 95/115/150/177 cd(EGC-HDVMH) EGC-HDVM series temporal-tone horn-strobes:one flash per second synchronized with optional EG1 M Genesis Signal Master indefinitely Strobe flash rate within 10 milliseconds(or self-synchronized within 200 milliseconds over thirty minutes on a common circuit without EG1 M Genesis Signal Master)Temporal setting(private mode only):synchronized to temporal output of horns on same circuit Synchronization Sources MEG1M-RM,GSA-CC1S,GSA-MCC1S,MIRMIRBPS6A, MIRMIRBPS1DA EGC-HDVM series temporal-tone horn-strobes:temporal rate synchronized with optional EG1 M Genesis Signal Master indefinitely Horn pulse rate within 10 milliseconds(or self-synchronized within 200 milliseconds over thirty minutes on a common circuit without EG1 M Genesis Signal Master) Temporal audible pattern '/2 sec ON,1/sec OFF,1/2 sec ON,1/2 sec OFF,1/2 sec ON,11/2 sec OFF,then repeat cycle Orcering Information Catalog Housing Ship Number Color Marking Description Wt.lbs (kg) EGC-HDVM White None Genesis Ceiling/Wall Horn-Strobe EGCF-HDVM White "FIRE" with selectable 15,30,75,or 95 cd output 0.82 EGCFR-HDVM Red "FIRE" (18) EGC-HDVMH White None Genesis Ceiling/Wall Horn-Strobe EGCF-HDVMH White_ "FIRE" _with selectable 95, 115,150,or 177 cd output Accessories— EG1 M-RM Genesis Signal Master—Remote Mount (1-gang) 0.2 (0.1) GSA-CCI S Intelligent Synchronization Output Module (2-gang) 0.5 (0.23) GSA-MCC1S Intelligent Synchronization Output Module (Plug-in UIO) 0.18 (0.08) White Field Configurable Ceiling Horn-Strobes may be ordered with or without optional'FIRE'marking.Red Horn-Strobes come with'FIRE"marking. N Page 4 of 4 85001-0559 Issue 1 EBPS6(10)A Booster Power Supply Battery Calculations Make entries in yellow highlighted boxes. Supervisory(AUX1,AUX2, AUX3,AUX4) Note:Only add auxiliary current if SW2-7 is OFF. Aux output stays on after AC power failure. Circuit Current(mA) Aux 1 0 AUX 2 0 3000mA max per Aux 3 0 ckt Aux 4 0 Number of ckts set to AUX: 35 0 Total AUX current(if switch SW2-7 is off): 0 mA(A) Supervisory current max=6A for EBPS6A; 8A for EBPS10A 200 mA AUX Current(mA) 4iiar 0 Total 200 mA AUX current: 0 mA(B) Rated base BPS supervisory current: 70 mA(C) Total supervisory current(A+B+C): 70 mA(D) Hours of supervisory: 24 Hrs (E) Supervisory mAH required (DxE): 1680 mAH (F) Alarm (NAC1, NAC2, NAC3, NAC4) Circuit Current(mA) NAC1 /Aux1 l .. 1.5 NAC2/Aux2 � 1.5 300omA � �: max per NAC3/Aux3 11` Jru — 1.476 ckt NAC4/Aux4 4 , ` ` 1.165 Total NAC current: 5.641 mA(G) Rated base BPS alarm current: 270 mA(H) Total alarm current (D+G+H): 345.641 mA(J) Minutes of alarm: 5 Min (K) Hours of alarm (K/60): 0.08 Hr(L) Alarm mAH required (JxL): 28.80 mAH (M) Total battery mAH required (M+F): 1708.80 mAH (N) Preliminary total battery AH required (N/1000): 1.71 AH (0) Final battery AH requirement(0 x 1.2): +' e AH (P) BPS-2 CIRCUIT CALCULATIONS NAC 1 MAX CURRENT USED FOR BATTERY CALCULATIONS NAC 2 MAX CURRENT USED FOR BATTERY CALCULATIONS NAC3 CD CURREN1QTY TOTAL EGCF-VM 15 0.109 5 0.545 30 0.151 3 0.453 EGCF-HDVM 30 0.108 1 0.108 75 0.185 2 0.37 1.476 NAC4 CD CURRENIQTY TOTAL EGCF-VM 15 0.109 8 0.872 30 0.151 0 0 EGCF-HDVM 30 0.108 1 0.108 75 0.185 1 0.185 1.165