Plans (378) BU P2018 - 00236 BUILDING LOCATION ,,.\''''...r -1*-D ARC yi MICHAEL C... WIRE THWANG rct SW 72ND AVENUE n TENANT IMPROVEMENT PORTLAND,OREGON r_ E iiiiriii��r �--L� for ,_ qj. 5851 v0 rl�rrtt F OF pS( �' 171: U U U Ur w I I I �� AUG 23 2018 PACTRUST PROJECT# 18420 r CITY OF TIGARD �IIIII� a+IIIIIIFQ BUILDING DIVISION _ ir aH+Hl 0IIIIII +Omet = r ]� t F - ,it-PI .r r N TENANT: Q \7 ---\__\ ,r. ADVANTAGE SALES AND - I if BUI_Jo _T M N J 0 7204 SW DURHAM RD, SUITE 100 T' �� I I � 0z l - 3- PORTLAND, OR 97224 �� -(� _ \\o„ I - , -- I— � �ttii nir� — 0 --- PROJECT NARRATIVE z �O �� tkt�iiir�i�ii�iiiiiiiiii PROJECT CONSISTS OF REMODEL WORK OF 8,028 SF OF EXISTING OFFICE. WORK SHALL Q V $ INCLUDE BUT NOT BE LIMITED TO DRYWALL/METAL STUDS,SUSPENDED CEILINGS, ��� DOORS/FRAMES AND PAINTING. ALL WORK SHALL COMPLY WITH ADA STANDARDS. Q n- ,, Q N 4 O a' o co WORK INCLUDED BUT PERFORMED UNDER SEP. PERMIT2 r2 .-1 o o 2 r2 «'z ( ' FIRE PROTECTION SPRINKLERING ENID HEATING,VENTILATION &AIR CONDITIONING WORK = U) o 0 ELECTRICAL WORK, BOTH LINE VOLTAGE AND LOW VOLTAGE V S Lc)y 2 BUILDING PLAN TOTBCI & II co TO a A-0 SCALE 1" = 30' Z BUILDING INFORMATION TENANT INFORMATION BUILDING OWNER: PACIFIC REALTY ASSOCIATES, L.P. TENANT: SPEC OFFICE 15350 SW SEQUOIA PKWY#300 PORTLAND,OR 97224 OCCUPANCY: B-8,028 SF (503)624-6300 (PHONE) r iii _� -- ,.. - - 7. 7. (503)624-7755(FAX) FLOOR AREA: 8,028 SF TOTAL ° BLDG. #: PBC BLDG.Q (pbc190) OCCUPANT LOAD: 80 r.1-- n _j_ir j_ . B- 11100=80 CONST.TYPE.: III-B 11 JL, EXITS REQUIRED: 2 1 • EXITS PROVIDED: 2 ' I. THIS BUILDING HOUSES THREE TENANTS. THE EXISTING ® All{ BUILDING IS A SINGLE STORY BUILDING OF 31,563 SF AND IS FULLY SPRINKLERED WITH AN NEPA 13 { r AUTOMATIC SPRINKLER SYSTEM. THERE IS FRONTAGE ON ALL FOUR SIDES OF AT LEAST 100' FEET. 6 ACTUAL BUILDING AREA TOTALS a� ■ U L inQ B OCCUPANCY = 22,201 SF _ S-1 OCCUPANCY = 9,362 SF nit) 1r ct =1 D • TOTAL 31,563 SF w a Cr LJ MIXED OCCUPANCY- NON-SEPERATED USES. (OSSC TABLE 508.4) Q NO SEPARATION BETWEEN OFFICE AND WAREHOUSE(STORAGE)REQUIRED J Ca �' ALLOWABLE AREA Q B 19,000+(75% INC. FOR FRONTAGE)+ (300% INC. FOR SPRINKLERS)=90,250 SF Q liklin -- - S 1 17,500 + (75% INC. FOR FRONTAGE)+(300% INC. FOR SPRINKLERS)=83,125 SF Z AREA OF WORK CODE SUMMARY w J ALL CONSTRUCTION WORK SHALL BE DONE IN COMPLIANCE Q WITH STATE AND LOCAL CODE REQUIREMENTS THAT APPLY, INCLUDING BUT NOT LIMITED TO: • 2014 OREGON STRUCTURAL SPECIALTY CODE w • 2014 OREGON MECHANICAL SPECIALTY CODE (OMSC) 0 I�-� BUILDING PLAN • 2014 OREGON PLUMBING SPECIALTY CODE (OPSC) 2ED • 2014 OREGON ELECTRICAL SPECIALTY CODE (OESC) Q -� SCALE 1" = 30' • 2014 OREGON FIRE CODE (OFC) I— [t • ASCE-7-10 w • ICC/ANSI A117.1-2009 V J Z w Qo • 2014 OREGON ENERGY EFFICIENCY SPECIALTY CODE 0 Q g c N < l L IF— S' = i' LL U >- oo ml I '')..----- INA 7.7 0 ,_ u) ,_ < 0. 0 0 a. tx REVISION I B '4 : '...7 7/7 IT B CITY OF TIGARD 1. WI= ® ® - I: Ili i. '''''--- a ..,. .. r-- I . Approved by Planning < 2 I -2 �. o -Z - -� Date: 3,I F17:1r: ® %: ;•f ' zz a W::r Initials: f( 3. 4. � I � � '—r 5. m 17) .1? °� - DEFERRED CITY OF TIGARD 6. J L REVIEWED FOR CODE COMPLIANCE 7. a i e 0 Fire Sprinkler IJ I� Fire Alarm Approved: I 4 Mechanical OTC: i '1 �� .r,_ ..,� ��7t p 1�� 8. U B S-1s-i ShopPluming ra V�.y c.v.i� 1 Electrical Permit #: 1��pa,�jls _� � DRAWN BY: _ U Truss Engineering Al.l7,.c-, : f SuJ S2 Shop Drawings --- �� MWN 9 Other F<<i+c +,`: i ) �� it I �� Dace: P)-.P 3-0 P�ERMITBID8/17SED1$ , Limmil.mT �� ter: - �. i AREA OF WORK OFFICE COPY A. 0 { A-0 BUILDING OCCUPANCY PLAN ZED BUILDING DEPARTMENT USE SCALE 1" = 30' 01 00 00 GENERAL DATA c. DURING PROGRESS OF WORK,KEEP JOB SITE CLEAN OF ALL PAINT MATERIALS, RUBBISH,CANS,AND INSIDE OF BUILDING WI LEAD FLASHINGS AT ROOF PENETRATIONS. LEAD ROOF JACKS TO BE SEALED AND ���D /1�� RAGS AT THE END OF EACH DAY. CLAMPED(STAINLESS STEEL WORM GEAR). H GENERAL REQUIREMENTS 12.ALL EXISTING AND NEW GAS PIPING EXPOSED TO THE EXTERIOR TO BE PROTECTED FROM RUST AND 09 00 00 FINISHES d. UPON COMPLETION OF WORK, CLEAN ANY PAINT SPLATTER BY USING PROPER METHODS OF WASHING c 1. ALL CONSTRUCTION WORK SHALL BE DONE IN COMPLIANCE WITH THE LATEST EDITION OF THE OREGON AND SCRAPING, USING CARE NOT TO SCRATCH OR DAMAGE FINISHED SURFACES. CORROSION WITH OIL BASED PAINT(COLOR GREY). `J � STRUCTURAL SPECIALTY CODE AND ALL OTHER STATE OR LOCAL CODE REQUIREMENTS THAT APPLY. GENERAL 13.LOW VOLTAGE IN SEALTITE CONDUIT FROM BELOW ROOF LINE DIRECT TO UNIT. DO NOT EXCEED BEND MICHAEL 2. VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON DRAWINGS AND AT THE EXISTING BUILDING AND 1. CLEAN,SEAL AND WAX ALL RESILIENT FLOORS PER MANUFACTURERS SPECIFICATIONS. e. PROTECT WORK OF OTHER TRADES. RADIUS OF MANUFACTURER'S GUIDELINE. C7 WIRE THWANGrri NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING THE WORK. 2. SUBMIT SAMPLES OR DRAW DOWNS FOR THE FOLLOWING: f. PROVIDE"WET PAINT'SIGNS AS REQUIRED TO PROTECT NEWLY PAINTED FINISHES. 14.ECONOMIZER TO MEET CODE AND AS FOLLOWS: L/J c---", 3. CONTRACTOR AND ALL SUBCONTRACTORS SHALL PERFORM DUE DILIGENCE INSPECTION OF ALL EXISTING ---i FLOOR CONDITIONS PRIOR TO SUBMITTAL OF A PROPOSAL.SUBMITTAL OF A PROPOSAL SHALL BE CONSIDERED a. COVERINGS, BASE AND TRANSITION STRIPS a. 6 TONS AND ABOVE MUST HAVE ECONOMIZER. • CONFIRMATION THAT SUCH INSPECTION HAS BEEN MADE,AND NO FURTHER COMPENSATION SHALL BE DUE b. PLASTIC LAMINATES 10 28 13 BREAK COUNTER b. BAROMETRIC RELIEF ON 5-7 1/2 TON UNITS. �� PORTLAND,OREGON t THE CONTRACTOR FOR CLAIMS ARISING AS A RESULT OF FAILURE TO PERFORM SUCH INSPECTION. 1. PAPER TOWEL DISPENSERS,SURFACE MOUNTED(KITCHEN/BREAK ROOM)BOBRICK B-262 / _ c. ALL NATURAL WOOD(INCLUDING DOORS AND CASEWORK) c. 8 TONS AND ABOVE MUST HAVE POWER EXHAUST. 5851 v 4. BY SUBMITTING A PROPOSAL,CONTRACTOR AND ALL SUBCONTRACTORS CERTIFY THAT THEY HAVE 1044 16 FIRE EXTINGUISHERS �/� O�� EXAMINED THE SITE AND INCLUDED IN THEIR PROPOSAL ALL WORK NECESSARY TO COMPLETE THE WORK d. PAINT d. 1 1/2 THRU 4-TON OSA INTAKE WITH DAMPER. c OF \` DESCRIBED OR REASONABLY IMPLIED IN THESE DOCUMENTS. THIS INCLUDES BUT MAY NOT BE LIMITED TO e. HARDWARE 1. FIRE EXTINGUISHER 2A10 BC (WALL MOUNTED OR IN SEMI RECESSED CABINET AS INDICATED ON PLAN) 15.ALL UNITS TO MEET OR EXCEED CURRENT ENERGY EFFICIENCY CODE REQUIREMENTS. (F- ALL MATERIALS AND INSTALLATION,DISPOSAL OF EXCESS MATERIALS(USEABLE FINISH MATERIALS SHALL BE 3. FINISH FLOORING TO EXTEND UNDER ALL NEW CASEWORK. 2. FIRE EXTINGUISHER CABINET: JL INDUSTRIES ACADEMY SERIES MODEL#C1027V10• 16.DROP CANS TO BE SAME SIZE AS CURB OPENING AND TO EXTENDED TO WITHIN 2'OF SUSPENDED CEILING.LEFT IN THE TENANT SPACE AS NOTED ON PLANS),CLEANING AND ALL PREPARATION OF SUBSTRATE 11 00 00 EQUIPMENT MINIMUM 26 GAUGE FOR SUPPLY AIR. SEAL EDGES OF SUPPLY AIR. SURFACES PRIOR TO INSTALLATION,AS WELL AS FINAL CLEAN UP. 4. PROVIDE A TRANSITION STRIP WHERE EVER TWO DIFFERENT FLOOR MATERIALS MEET PROJECT# 18420 5. IT IS THE INTENT OF THESE CONTRACT DOCUMENTS TO MATCH AND MAINTAIN EXISTING BUILDING 1. TENANT SUPPLIED 17.DISTRIBUTION DUCTWORK: STANDARDS FOR ALL EXISTING PRODUCTS AND SYSTEMS. UPON DISCOVERY OF A DISCREPANCY TO THIS 09 21 00 GYPSUM BOARD a. KITCHEN RANGE: AMANA-30"FREESTANDING ELECTRIC RANGE. a. SPIRAL DUCT PERMITTED ONLY IF EXPOSED. INTENTION,THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY. 2. CONTRACTOR SUPPLIED AND INSTALLED b. 26 GAUGE OR TO SMACNA STANDARDS WHERE DUCT IS CONCEALED ABOVE A CEILING. 6. FURNISH ALL NEW MATERIALS EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE. GENERAL 1. ALL GYPSUM BOARD WALLS: ONE LAYER 5/8"TYPE X GYPSUM WALLBOARD, EITHER AT RIGHT ANGLES OR b. KITCHEN RANGE HOOD- BROAN-F40000 SERIES TWO SPEED,4-WAY CONVERTIBLE,RANGE HOOD. c. WRAP CONCEALED SUPPLY DUCTWORK IN NON-CONDITIONED AND SEMI-CONDITIONED SPACE WITH 7. COORDINATE THE WORK OF ALL TRADES. PROVIDE CARPET"WALK-OFF MATS"TO PROTECT EXISTING PARALLEL TO FRAMING ON EACH SIDE OF METAL STUDS SPACED AT 24"Q.C. FASTEN WITH 1"TYPE S 12 00 00 FURNISHINGS MINIMUM R4.2 INSULATION WITH FSK BARRIER. CARPETS. DRYWALL SCREWS 8"O.C.TO VERTICAL EDGES AND 12"O.C.TO TOP AND BOTTOM RUNNERS AND d. HANGERS 12 GAUGE WIRE OR 18-GAUGE 1"WIDE STRAP. EXPOSED DUCT MUST HAVE ALL THREAD 8. ALL ROOF PENETRATIONS FROM ABANDONED EQUIPMENT TO BE REMOVED. PATCH AND REPAIR ROOF AND INTERMEDIATE STUDS. STAGGER ALL VERTICAL AND HORIZONTAL JOINTS 24"O.C.(OR ONE STUD SPACING), 1. CLEAN!REFURBISH EXISTING BUILDING STANDARD BLINDS AT ALL EXTERIOR GLASS. HANGERS AND FULL DIAMETER STRAP UP TO 18"0. LARGER THAN 18"MUST HAVE SADDLE TYPE CLAMP. ROOF MEMBRANE TO MATCH THE EXISTING ROOF. EACH SIDE AND OPPOSITE SIDES.. 12 23 16 CABINET SPECIFICATIONS e. BRANCH DUCTS SHALL BE PLUMB AND SQUARE(NO OCTOPUS). TEES SHALL BE MAXIMUM OF 45 Q 9. ALL ROOF WORK TO BE PERFORMED BY PACTRUST APPROVED ROOFING COMPANIES. APPROVED 2. ALL OFFICE GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND TWO FINISH COATS WITH SANDING BETWEEN 1. ALL CABINETRY TO BE INSTALLED OVER FINISH FLOOR AT ALL RESILIENT FLOORING LOCATIONS. DEGREES. COMPANIES INCLUDE: FINISH COATS(LEVEL 4 FINISH). APPLY USG SHEETROCK BRAND FIRST COAT. PAINT AS INDICATED. 2. AWl CUSTOM GRADE STANDARDS FOR CASEWORK AND COUNTER TOPS U.N.O f. EACH BRANCH DUCT TO HAVE BALANCE DAMPER IN Y BRANCH. a. ARROW ROOFING, 503-460-2767 3. ALL OTHER GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND ONE FINISH COAT WITH SANDING AFTER FINISHZ b. PACIFIC ROOFING,503-640-3163 COAT(LEVEL 3 FINISH). PAINT AS INDICATED. 3. HIGH PRESSURE LAMINATE(P-LAM HPL)ALL EXTERIOR SURFACES, INCLUDING 4"TOE KICK. EDGE BANDING g. ALL DISTRIBUTION DUCT WORK TO BE INSTALLED MIN.24"ABOVE FINISH CEILING. (MATCHING PVC ACCEPTABLE), FIN ENDS,DOORS,AND LIGHT VALENCE ETC. UPPER CABINET BOTTOMS 18.FLEX DUCT WILL BE NO LONGER THAN 6'FROM RIGID DUCT DOWN TO DIFFUSER. c. ROOF TOPPERS,360-574-7248 4. IN FINISHED SPACES FURR-OUT BUILDING COLUMNS AND EXTERIOR WALLS WITH 5/8"GYPSUM BOARD OVER OPTIONAL HPL FINISH,STANDARD MELAMINE FINISH. OPEN CABINETS OPTIONAL HPL FINISH,STANDARD METAL STUDS. MELAMINE FINISH. 19.DIFFUSERS: d. GOT YOU COVERED ROOFING,503-975-9136 5. PROVIDE ACOUSTIC GASKETS WHERE WALL INTERSECTS STOREFRONT.QUIETJOINT SHH WHERE WALL 4. TOE KICK PLYWOOD 4"H WITH P-LAM COVER a. SUSPENDED CEILING SYSTEM(T-BAR)-PERFORATED FACE ADJUSTABLE CURVED BLADES-DESIGN 10.KEEP THE AREA OF WORK FREE OF GARBAGE AND DEBRIS ON A DAILY BASIS INCLUDING DOCK ACCESS MEETS MULLION AND QUIETJOINT SHG WHERE WALL MEETS GLAZING.COLOR SELECTED BY ARCHITECT. TITUS PCS SUPPLY AND TITUS PAR RETURN OR APPROVED EQUAL. AREAS AND COMMON AREA. FLOORS TO BE SWEPT OR VACUUMED DAILY. 5. DOORS AND DRAWER FRONTS PLASTIC LAMINATE OVER 11116"PARTICLE BOARD WITH MATCHING P-LAM. 0 6. AT ALL EXISTING WALLS,REMOVE ALL NAILS,SCREWS,FASTENERS,ETC.LEFT BY PREVIOUS TENANT AND b. GYPSUM BOARD CEILING;SUPPLY-CURVED BLADE W/OBD DESIGN TITUS 250; RETURN-BAR TYPE- 11.PROVIDE ADEQUATE PROTECTION TO ALL EXISTING IMPROVEMENTS INCLUDING BUT NOT LIMITED TO PATCH HOLES READY FOR PAINT. 6. MELAMINE(LOW PRESSURE LAMINATE/LPL)ALL INTERIOR AREAS,DRAWER PARTS,SHELVING ETC, UNLESS DESIGN TITUS 350; EXHAUST-METAL OR ALUMINUM-1/2"x 112"EGG CRATE DESIGN TITUS 50F. Z COMMON CORRIDORS AND STAIRS,BUILDING ENTRANCES,SUITE ENTRANCES, ETC. THE CONTRACTOR WILL INDICATED D1FERRENTLY IN THE DRAWINGS.. 7. REPAIR GYPSUM BOARD AT REMOVED ELECTRICAL RECEPTACLES OR DATA BOXES AND FINISH READY FOR c. ALL SUPPLY REGISTERS TO HAVE MANUAL VOLUME DAMPERS LOCATED IN DUCT AT OR NEAR CLOSEST Q BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGES TO EXISTING IMPROVEMENTS DUE TO CONSTRUCTION 7. FLUSH OVERLAY/FRAMELESS STYLE CONSTRUCTION. o ACTIVITIES. PAINT WYE BRANCH. 12.PROVIDE TEMPORARY SANITARY FACILITIES. CONSTRUCTION WORKERS SHALL NOT USE BUILDING 8. UPON REMOVAL OF WALL BASE, REMOVE RESIDUAL ADHESIVE AND PREP WALL TO PAINT READY CONDITION. 8. THERE SHOULD BE 118"OR LESS GAP TOLERANCE BETWEEN DOORS AND DRAWERS. d. CLEAN OR REPLACE ALL SUPPLY AND RETURN AIR GRILLS AND THEIR HOUSINGS AT PROJECT RESTROOM FACILITIES. WALL CONSTRUCTION MATERIALS 9. HINGES-BLUM#75M3580, 110 DEG.SELF CLOSING CLIP ON (OR EQUAL). COMPLETION. 10.DRAWER SLIDES-BLUM #239M SERIES EXTENSION(OR EQUAL)75 LBS.MIN.FOR STANDARD DRAWERS. 20.THERMOSTAT: ALL EXISTING MERCURY TYPE THERMOSTATS TO BE REPLACED. NEW THERMOSTATS TO BE w 13.STORAGE AND STAGING TIF CONSTRUCTION MATERIALS SHALL BE LIMITED TO UTILITASY AS DESIGNATEDNYTT 1. PROVIDE STUDS,TRACKS,BRACING, FASTENING AND OTHER ACCESSORIES NECESSARY FOR COMPLETE ACCURIDE#4032(OR EQUAL)HD/FULL EXT 150 LBS. MIN.FOR HD AND FILE DRAWERS. HONEYWELL COMMERCIAL GRADE VISIONPRO 8000 TOUCH SCREEN MODEL T88220U1003 WHERE POSSIBLE. 1 d N PRE-CONSTRUCTION MEETING. UNDER NO CIRCUMSTANCES SHALL BUILDING UTILITY AREAS OR ANY OTHER INSTALLATION. APPROVED SUBSTITUTE: TOTAL-LINE SIGNATURE COMMERCIAL THERMOSTAT MODEL NO.P374-2800 -7 DAY - Q COMMON BUILDING AREA BE USED FOR STORAGE. 2. FRAMING MEMBERS SHALL HAVE THE STRUCTURAL PROPERTIES INDICATED WHERE PHYSICAL STRUCTURAL 11.PULLS-96 MM C-TO-C WIRE PULLS. FINISH TO MATCH DOOR HARDWARE. PROGRAMMABLE WITH LOCKOUT FUNCTION-AUTO CHANGEOVER ONLY. MOUNT AT ADA HEIGHT(MAY Q c u7 14.KEEP THE ROOF FREE OF DEBRIS(I.E.NAILS,SCREWS,BOTTLES,ETC.)AT ALL TIMES. PROPERTIES ARE NOT INDICATED,THEY SHALL BE AS NECESSARY TO WITHSTAND ALL IMPOSED LIVE LOADS. 12.GENERAL CONTRACTOR TO PROVIDE CABINET MAKER WITH SINK TEMPLATE(SPEC SHEETS)FOR EACH SINK. REQUIRE CHANGING HEIGHT AT"REPLACEMENT"LOCATIONS). MOUNT ADJACENT TO LIGHT SWITCHES. f: O 15.ALL DIMENSIONS ARE TO FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. DESIGN FRAMING IN ACCORDANCE WITH AISI SG-673. SINK CUTOUT SHALL BE DONE IN SHOP WHEN FEASIBLE AND BEFORE BACK SPLASH IS INSTALLED IN ALL CONTRACTOR SHALL PROGRAM THERMOSTATS AND BALANCE SYSTEM. J 0 0 co r� 3. COLD-FORMED FRAMING SHALL BE GALVANIZED METAL CONFORMING TO ASTM A446IA 446 M GRADE A(33000 CASES TO ALLOW CUT OUT TO BE POSITIONED PROPERLY. ALL RAW EDGES OF CUT OUT AND BACK SPLASH 21.THERMOSTAT LOCATIONS TO BE REVIEWED BY ARCHITECT PRIOR TO INSTALLATION. UJ CO p c N 16.CONFIRM SIZES OF ALL OPENINGS REQUIRED FOR THE INSTALLATION OF STRUCTURAL,MECHANICAL, PSI)G60. TO BE SEALED. MINIMIZE COUNTERTOP BUILD UPS AT FRONT AND BACK OF SINK CUT OUT TO Q Z (ID co ELECTRICAL AND PLUMBING WORK PRIOR TO FRAMING OR CUTTING FOR INSTALLATION. ACCOMMODATE PLUMBERS SINK CLAMPS CLEARANCE. 22.EXHAUST FANS: Q 17.LEAVE THE PROJECT CLEAN AND READY FOR OCCUPANCY. 4. PROVIDE THE LISTED GYPSUM BOARD PRODUCTS BY U.S.GYPSUM,GEORGIA PACIFIC, NATIONAL GYPSUM OR 4" a. CEILING MOUNTED EXHAUST FANS SHALL HAVE A MINIMUM PERFORMANCE TO MEET THE CURRENT 2 0I- c-73-c-75- S uo0 13.KITCHEN/BREAK ROOM CABINETS-BASE CABINET WITH P-LAM TOP ON PLYWOOD DECKING AND BACK 0AN APPROVED EQUAL. SPLASH. ALL CABINETS TO HAVE DOORS AND DRAWERS, U.N.O. UPPERS 12"D X 36"H-ATTACH TO WALL CODE REQUIREMENTS INCLUDING INTEGRAL BACKDRAFT DAMPER AND VENTING TO THE EXTERIOR. cn IY 18.CLEAN ADJACENT EXTERIOR AREA, I.E.WALKS, EXTERIOR GLASS,ETC. c*� "'-' 5. STANDARD GYPSUM BOARD SHALL BE TYPE'X', 5/8"THICK WITH TAPERED EDGES CONFORMING TO ASTM WITH FRENCH CLEAT,COUNTER AND COUNTERTOPS 24"DEEP. MICROWAVE SHELF 18"D WITH 3"RADIUS COOK GEMINI SERIES 100 OR EQUAL;80 CFM WITH A SONE RATING OF 1.6 OR LESS, 100 CFM WITH A C Ln 0 Z X 19.FILL ALL PAPER AND SOAP DISPENSERS IN RESTROOMS AND BREAK AREAS. C-36. OUTSIDE CORNERS. P-LAM AT TOE/BASE. ALL SHELVES ADJUSTABLE.PROVIDE HOLES AND POSTS(1 AT SONE RATING OF.9 OR LESS,200 CFM WITH A SONE RATING OF 1.6 OR LESS. C r- CI_ 20.CLEAN ALL SUPPLY AND RETURN DIFFUSERS AT PROJECT COMPLETION. 6. WATER RESISTANT GYPSUM BOARD SHALL BE 5/8"THICK WITH TAPERED EDGES. CONFORMING TO ASTM BASE,2 AT UPPERS). b. SPECIALTY ROOMS REQUIRING EXHAUST SHALL MEET THE ABOVE MINIMUM REQUIREMENTS- 21.PROVIDE"AS BUILT"DRAWINGS OF THE WORK AT THE CONCLUSION OF CONSTRUCTION."AS BUILT" C-630. 14.WORK/COPY/STORAGE CABINETS-BASE CABINETS WITH P-LAM TOP ON PARTICLE BOARD DECKING. SCRIBE INDIVIDUAL ROOMS WITH AN EXHAUST REQUIREMENT GREATER THAN 250 CFM,SHALL HAVE A DRAWINGS MAY BE IN THE FORM OF TWO COPIES OF CONSTRUCTION DOCUMENTS MARKED-UP WITH RED 7. TRIM ACCESSORIES SHALL COMPLY WITH ASTM C-1047. COUNTERTOPS TO WALLS. ALL CABINETS OPEN MELAMINE STANDARD INTERIORS WITH DRAWERS, U.N.O. ROOFTOP MOUNTED FAN. PEN.DELIVER RECORD DRAWINGS TO THE ARCHITECT. COMPLETE OPERATION AND MAINTENANCE MANUALS UPPERS AT 15"D X 30"H -ATTACH UPPERS TO WALL WITH FRENCH CLEAT. BASES AT 24"D X 34"H. P-LAM AT 23.HVAC TESTING. WALL CONSTRUCTION EXECUTION TOE/BASE. ALL SHELVES ADJ. HOLES AND POST(1 AT BASE, 1 AT UPPERS). SHALL BE PROVIDED FOR ALL MECHANICAL,ELECTRICAL AND PLUMBING EQUIPMENT.PROVIDE AS-BUILT CAD a. CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES,COMPONENTS, FILES TO PACTRUST FOR ALL MEP TRADES.PACTRUST MAY HOLD CONTRACTOR'S FINAL PAYMENT UNTIL 1. FASTEN FRAMING MEMBERS TOGETHER BY WELDING OR BY USING SELF-DRILLING OR SELF-TAPPING 15.WORK COUNTER TOPS-COUNTER TOPS WITH P-LAM ON PARTICLE BOARD DECKING. SCRIBE COUNTERTOPS EQUIPMENT AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE!N ACCORDANCE WITH "AS-BUILT"DRAWINGS AND 0&M MANUALS HAVE BEEN RECEIVED AND APPROVED. SCREWS. WELDING SHALL CONFORM TO AWS D13 WELDING PROCEDURE. ELECTRODES AND SCREW TO WALLS. PROVIDE GROMMET HOLES ABOVE ALL POWER AND DATA LOCATIONS. PROVIDE STEEL MID SPAN APPROVED PLANS AND SPECIFICATIONS. 22.17 IS THE INTENT OF THE CONTRACT DOCUMENTS THAT THE CONTRACTOR PROVIDE A COMPLETE, CONNECTIONS SHALL BE AS REQUIRED AND INDICATED IN THE DESIGN CALCULATIONS. DO NOT FIELD WELD SUPPORTS AS NEEDED EQUAL TO WORK STATION BRACKETS AS MFG.BY A&M HARDWARE,INC FUNCTIONING PROJECT INCLUDING ALL GENERAL,MECHANICAL AND ELECTRICAL CONSTRUCTION REQUIRED MATERIALS LIGHTER THAN 18 GA. (888-647-0200). b. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN TO FULFILL THAT INTENT. ALL ITEMS REQUIRED SHALL BE FURNISHED AND INSTALLED,REGARDLESS OF 2. PROVIDE ACCURATELY ALIGNED RUNNERS AT TOP AND BOTTOM OF PARTITIONS. ANCHOR TRACKS AS ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. WHETHER OR NOT SHOWN ON THE DRAWINGS. INDICATED IN THE DESIGN CALCULATIONS. BUTT WELD JOINTS IN TRACKS OR SPLICE WITH STUD INSERTS. 21 00 00 FIRE SUPPRESSION : DESIGN/BUILD c. A COMPLETE COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND 23.LTEMS OR WORK NOT TO BE FURNISHED OR ACCOMPLISHED BY CONTRACTOR ARE NOTED"N.I.C.". FASTENERS SHALL BE AT LEAST 3 INCHES FROM THE EDGE OF CONCRETE SLABS. FILED WITH PACTRUST. 3. CUT STUDS SQUARE AND SET WITH FIRM BEARING AGAINST WEBS OF TOP AND BOTTOM TRACKS. POSITION 1. PROVIDE SPRINKLERS THROUGHOUT SPACE AS REQUIRED BY CODE. SPRINKLER HEADS SHALL BE 24.PROJECT CLOSE OUT DOCUMENTS REQUIRED: 24."ALIGN"AS USED IN THESE DOCUMENTS,MEANS TO ALIGN THE FINISHED FACES OF ELEMENTS IN THE SAME STUDS VERTICALLY IN TRACKS AND SPACE AS INDICATED IN DESIGN. DO NOT SPLICE STUDS. PROVIDE AT CENTERED IN 2 X 2 CEILING TILE. LAYOUT OF SPRINKLERS BY CONTRACTOR. SPRINKLER LAYOUT IN ALL HARD PLANE, EITHER IMMEDIATELY ADJACENT TO ONE ANOTHER OR ACROSS AN OPENING. LEAST TWO FULL HEIGHT KING STUDS AT DOORS AND OTHER OPENINGS 2 FEET WIDE OR LARGER. PROVIDE CEILING AREAS(GYPSUM BOARD/PLASTER)TO BE REVIEWED AND APPROVED BY ARCHITECT PRIOR TO a. AutoCAD FILE SHOWING AS-BUILT INFORMATION. 25.D0 NOT DISASSEMBLE SETS OF CONSTRUCTION DRAWINGS.DRAWINGS ARE INTERRELATED. JACK STUDS OVER OPENINGS,AS NECESSARY,TO MAINTAIN INDICATED STUD SPACING. PROVIDE TRIPLE INSTALLATION. b. ELECTRONIC PDF FILE OF THE AutoCAD FILE ABOVE. 26.SUBMIT SAMPLES OR DRAW DOWNS FOR ALL FINISHES REQUESTED TO THE ARCHITECT OF RECORD WITHIN STUDS AT CORNERS, POSITIONED TO RECEIVE INTERIOR AND EXTERIOR FINISHES. FASTEN STUDS AT TOP 2. IN NEW CEILING GRID SYSTEMS OVER 144 SF PROVIDE FLEXIBLE HEADS FOR MINIMUM SEISMIC MOVEMENT. c. HARD COPY OF AutoCAD FILE ABOVE. TWO WEEKS OF PROJECT AWARD.PRODUCTS INSTALLED WITHOUT APPROVED SAMPLES ARE SUBJECT TO AND BOTTOM TRACKS BY WELDING OR SCREWING BOTH FLANGES TO THE TRACKS.PROVIDE LONG LEG NO"OOPS RINGS ALLOWED". REPLACEMENT AT CONTRACTOR COST.AN APPROVED SUBMITTAL DOES NOT CHANGE THE CONTRACTUAL TRACK AT TOP OF WALL TO ALLOW FOR DEFLECTION WHERE WALL MEETS STRUCTURE ABOVE, 22 00 00 PLUMBING : DESIGN 1 BUILD d. OPERATIONS MANUALS FOR ALL EQUIPMENT, INCLUDING T-STATS. REQUIREMENT TO PROVIDE THE SPECIFIED ITEMS UNLESS SPECIFICALLY NOTED AS A SUBSTITUTION BY THE 4, INSTALL ALL INTERIOR AND EXTERIOR GYPSUM BOARD PRODUCTS AND ACCESSORIES AS REQUIRED FOR e. COLORED ZONE MAP WITH THERMOSTAT LOCATIONS INDICATED. CONTRACTOR AND SPECIFICALLY APPROVED BY THE ARCHITECT AS SUCH.REPLACE SUCH PRODUCTS AS THE PROJECT. GENERAL REQUIREMENTS 26 00 00 ELECTRICAL : DESIGN 1 BUILD DIRECTED AT CONTRACTOR'S COST. 5. COMPLY WITH USG GYPSUM CONSTRUCTION HANDBOOK AND MANUFACTURER'S RECOMMENDATIONS. 1. CONTRACTOR TO SUBMIT LAYOUT ON ELEVATIONS AND PLANS PROVIDED FOR ALL SHUT OFF VALVES,CLEAN 27.SUBMIT COMPLETE SHOP DRAWINGS FOR MILLWORK,SPECIAL SYSTEMS,MECHANICAL, ELECTRICAL AND OUTS,ACCESS DOORS,AND FLOOR DRAINS TO THE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. GENERAL PLUMBING SYSTEMS(INCLUDING FIRE PROTECTION SYSTEMS). SUBMIT A MINIMUM OF TWO COPIES OF ALL 6. FINISH QUALITY: 2. PLUMBING CONTRACTOR TO PROVIDE AND INSTALL(1)MASTER SHUT OFF VALVE FOR EACH SET OF 1. ALL ELECTRICAL FEEDS TO OUTLETS,SWITCHES,ETC. MUST BE VERTICAL DROPS FROM ABOVE EXCEPT FOR SHOP DRAWINGS FOR REVIEW AND APPROVAL TO THE ARCHITECT OF RECORD.ARCHITECT WILL RETAIN ONE AREA PROCESS TRADE NOMENCLATURE RESTROOMS. LOCATE VALVE BEHIND HANDICAP WATER CLOSET IN MEN'S TOILET ROOM. HORIZONTAL RUNS UNDER WINDOWS AND RECEPTACLES ON THE SAME STUD. COPY AND ONE COPY WILL BE RETURNED TO THE CONTRACTOR. WAREHOUSE TAPE/FINISH COAT' TIGHT DOUBLE(LEVEL 3) 3. ALL DOMESTIC WATER PIPING TO BE TYPE L COPPER-NO EXCEPTIONS. ALL EXPOSED PIPING TO BE 2. ALL ELECTRICAL FEEDS TO OUTLETS AND DATA BELOW WINDOW SILLS TO BE ROUTED THROUGH BUILDING 28.THE DESIGN OF FIRE PROTECTION SYSTEMS IS THE RESPONSIBILITY OF THE FIRE PROTECTION SYSTEMS AREAS TAPE/2 FINISH COATS'/ SMOOTH FINISH TAPED(LEVEL 4) INSULATED. SHELL WALLS. DO NOT FEED FROM PERPENDICULAR INTERIOR PARTITIONS. CONTRACTOR.ALL FIRE PROTECTION SYSTEMS SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER 3. ALL NEW ELECTRICAL DEVICES TO BE WHITE LICENSED BY THE APPROPRIATE JURISDICTION FOR THE DESIGN OF THIS TYPE OF SYSTEM. COORDINATE USG"FIRST COAT" 'SAND AFTER TAPE 1 FINISH COAT(S) 4. WATER HEATER(ELECTRIC)30 GAL AND LARGER 277V LESS THAN 30 GAL 120V. PROVIDE HUB DRAIN AT INTERFACE WITH EXISTING BUILDING SYSTEMS AND WITH ARCHITECT. ALL SPRINKLER HEADS SHALL BE NOTE:AT EXTREMELY DARK ACCENT WALLS PROVIDE LEVEL 5 FINISH. LOCATION FOR BLOW OFF. 4. PROVIDE LABELS AT EACH ELECTRICAL RECEPTACLE IDENTIFYING CORRESPONDING PANEL AND BREAKER. a)CENTERED IN CEILING TILE(OR 2 x 2 MODULE OF A SECOND LOOK II TYPE OF CEILING TILE WHERE 5. FLOOR DRAINS SHALL BE INSTALLED IN TOILET ROOMS CONTAINING TWO(2)OR MORE WATER CLOSETS OR 2 5. PROVIDE TYPEWRITTEN UPDATED SCHEDULE AT PANEL TO IDENTIFY CIRCUIT BREAKERS. 0 APPLICABLE). LOCATION OF THOSE IN GYPSUM BOARD CEILINGS SHALL BE PRE-APPROVED IN WRITING BY OR MORE WATER CLOSETS AND URINALS IN COMBINATION. THE FLOOR SHALL SLOPE TOWARD THE FLOOR Z 7 in THE ARCHITECT PRIOR TO INSTALLATION. 7. FINISH EXPOSED INTERIOR GYPSUM BOARD WALLS AND CEILINGS SMOOTH STRAIGHT READY FOR FINISH AS DRAIN. 6. VERIFY ELECTRICAL METER AND TAG METER WITH THE TENANT'S ADDRESS OR SUITE NUMBER. METER a 29.COORDINATE ALL CONSTRUCTION SEQUENCING WITH PACTRUST AND SCHEDULE ALL SERVICE SHOWN ON PLANS. IDENTIFICATION NUMBER AND TENANT ADDRESS INFORMATION SHALL BE GIVEN TO PACTRUST PRIOR TO 6. FLOOR DRAINS TO BE INSTALLED WITH PRIMER VALVE WITH ISOLATION VALVE. NO ATMOSPHERIC PRIMERS. TENANT'S MOVE-IN. INTERRUPTIONS OUTSIDE NORMAL BUSINESS HOURS TO MINIMIZE INCONVENIENCE TO CURRENT TENANTS. 09 53 00 SUSPENDED ACOUSTICAL CEILING DRAINS TO BE PRIMED FROM TOILET FIXTURES UNLESS OTHERWISE APPROVED BY PACTRUST. PROVIDE A d GENERAL 1. COMPLY WITH CURRENT SEISMIC REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE. MIN. 12"x 12"ACCESS DOOR. 7. ELECTRICAL CONTRACTOR TO PROVIDE EMERGENCY LIGHTING IN EXIT PATH SHOWN ON PLAN EQUAL TO W - 1-FOOT CANDLE. 0 1. REMOVE ALL EXISTING VCT,SHEET VINYL,ETC. IN AREAS WHERE NEW FLOOR COVERING IS SPECIFIED PRIOR 2. FOLLOW MANUFACTURERS PRINTED INSTRUCTIONS FOR THE DELIVERY AND INSTALLATION OF CEILING PLUMBING-BREAK ROOM FIXTURES 8. EXIT LIGHTS: RUUD LIGHTING"PLASTIC LED EXIT SIGN"MODEL EXPBURWH RED LETTERS,WHITE HOUSING, 0 TO INSTALLATION OF NEW FLOORING. SYSTEM, INCLUDING GRID,PANELS,AND HANGARS AND ACCESSORIES, 1. REUSE EXISTING FIXTURES WHERE POSSIBLE. WITH BATTERY BACKUP. 2. ALL ROOF PENETRATIONS FOR ELECTRICAL,LOW VOLTAGE,GAS PIPING,ETC.SHALL BE SLEEVED THROUGH 3. USE ALL PRODUCTS FROM ARMSTRONG WORLD INDUSTRIES, INC. 2. BREAK ROOM SINK ELKAY LRAD221955(TOP MOUNT) 9. WHERE NEEDED,CONTRACTOR TO FURNISH AND INSTALL NEW DRY TYPE TRANSFORMERS TO PROVIDE < Jm A LEAD ROOF JACK,CLAMPED WITH A STAINLESS STEEL CLAMP AND SEALED WITH VULKEM 921 POLYURETHANE SEALANT. SILICONE SEALANT NOT PERMITTED. 4. CO-ORDINATE CEILING WORK WITH INSTALLERS OF RELATED WORK INCLUDING BUT NOT LIMITED TO 3. BREAK ROOM FAUCET-AMERICAN STANDARD COLONY SOFT SINGLE CONTROL FAUCET#4175.500 208V/120V POWER FROM THE 480V1277V SYSTEM. SIZE TO BE BIDDER DESIGN. INSULATION,GYPSUM BOARD,LIGHT FIXTURES, MECHANICAL SYSTEMS,ELECTRICAL SYSTEMS AND FIRE QUIET ROOM SINK-COUNTERTOP LAVATORY KOHLER PENNINGTON K-2196-4,OR AMERICAN STANDARD a. TRANSFORMERS TO BE ENERGY STAR LABELED. 01 73 29 CUTTING AND PATCHING SPRINKLERS 4. RONDALYNb. CASE TO BE TOTALLY ENCLOSED WITH LOUVERS TO PREVENT FOREIGN OBJECTS INTO THE INTERIOR. 01. PERFORM CUTTING AND PATCHING WITH SKILLED CRAFTSMEN EXPERIENCED WITH THE TYPE OF WORK 5. PRODUCTS: BEING UNDERTAKEN. a. GRID MATCH EXISTING 5. QUIET ROOM FAUCET-KOHLER-CORALAIS K-15241-ARA-CP c. ENCLOSED AND VENTILATED,AIR COOLED TYPE,CLASS H INSULATION,DESIGNED FOR 115 DEGREES C z 2. PROTECT EXISTING CONSTRUCTION TO PREVENT DAMAGE. 6. DISHWASHER-REUSE EXISTING. TEMPERATURE RISE ABOVE 40 DEGREES C AMBIENT TEMPERATURE AT FULL LOAD CONTINUOUS b. TILES-REUSE EXISTING, IF MORE TILE IS NEEDED,MATCH EXISTING OPERATION. EQUIP WITH 2-1/2 PERCENT ANFC TAPS AND FOUR 2-1/2 PERCENT BNFC TAPS. MAXIMUM PROJECT CLOSE OUT DOCUMENTS REQUIRED: 3. PERFORM CUTTING USING METHODS LEAST LIKELY TO DAMAGE ELEMENTS TO BE RETAINED. c. ACCESSORIES MANUFACTURER'S STANDARD SOUND LEVEL SHALL BE NEMA STANDARD WITH ISOLATION DAMPERS BETWEEN THE CORE AND COIL r� 1. PROVIDE AS-BUILT INFORMATION TO ARCHITECT AT PROJECT COMPLETION. INCLUDE THE FOLLOWING: ASSEMBLY AND CASE. V J 4. PATCH,USING MATERIALS IDENTICAL TO EXISTING MATERIALS THAT VISUALLY MATCH EXISTING ADJACENT 6. ALL TILE CUTS SHALL BE DONE WITH RAZOR SHARP KNIVES. CUT/TRIM TILE EDGE TO CREATE TEGULAR EDGE SURFACES TO THE FULLEST EXTENT POSSIBLE CONDITION SO THAT CEILING TILES LAY FLAT. a. DIMENSIONS (HORIZONTAL AND VERTICAL)OF BUIRED PLUMBING LINES INSTALLED OR DISCOVERED BY 10.FOR FLOOR POWER AND DATA ACCESS w 5. PATCH WITH DURABLE,INVISIBLE SEAMS THAT ELIMINATE EVIDENCE OF PATCHING AND REFINISHING. THIS CONSTRUCTION. a. AT RAISED SLABS:USE WIREMOLD RC7 FLUSH POKE-THRU SERIES OR EQUAL J 7. CEILINGS LESS THAN OR EQUAL TO 144 SF AND SURROUNDED BY WALLS CONNECTED TO THE STRUCTURE 6. AT CONCRETE SLAB REPAIRS(POUR BACKS), PROVIDE#3 x 12"LONG REPAR DOWELS AT 24"O.C. MIN.WITH ABOVE ARE EXEMPT FROM THE SEISMIC DESIGN REQUIREMENTS. b. LOCATION OF SHUT OFF VALVES b. AT SLAB ON GRADE:USE WIREMOLD RFB4E BOX WITH 6CTC2 COVER AT CONFERENCE ROOMS AND MIN.6"PENETRATION INTO EXISTING CONCRETE AND MIN.OF 6"EXPOSURE INTO POUR BACK.CENTER B. CEILING AREAS OF 1,000 SF OR LESS SHALL BE EXEMPT FROM LATERAL-FORCE REQUIREMENTS. 23 00 00 HVAC : DESIGN 1 BUILD 6CFFTC COVER AT FURNITURE FEEDS.PROVIDE 1"CONDUIT FOR POWER AND 2"CONDUIT FOR DATA. CT)^ DOWEL IN SLAB DEPTH. I 1.LOW VOLTAGE SYSTEMS(TELECOMMUNICATION AND DATA)BY FUTURE TENANT. V, 7. REMOVE PATCHES THAT ARE VISUALLY UNSATISFACTORY IN THE ARCHITECT'S OPINION AND REPLACE AT NO 9. INSTALL CEILING GRID WITH TWO EDGES ATTACHED TO ADJACENT WALLS. THE OTHER TWO EDGES SHALL BE GAS METER ADDITIONAL COST. ATTACHED TO WALL MOLD USING BERC2 CLIPS ALLOWING THOSE TWO SIDES TO FLOAT. 1. CONTRACTOR TO VERIFY GAS METER AND TAG METER WITH THE TENANTS ADDRESS OR SUITE NUMBER. 12.LIGHTING ENERGY MANAGEMENT IS REQUIRED IN BUILDING AREAS 5,000 SF AND LARGER. W 10.PROVIDE CEILING SEISMIC JOINTS AT LOCATIONS AS SHOWN TO LIMIT CONTIGUOUS CEILING GRID AREAS TO METER IDENTIFICATION NUMBER AND TENANT ADDRESS INFORMATION SHALL BE GIVEN TO PACTRUST PRIOR 13.OCCUPANCY CONTROL DEVICES SHALL BE LEVITON OR WATT STOP. V 03 00 00 CONCRETE NO MORE THAN 2500 S.F.THE STATIONARY SIDE OF THE JOINT SHALL PERMIT THE INSTALLATION OF A LIGHT TO TENANT'S MOVE-IN. 14.TEST ALL LIGHTING CONTROL SYSTEMS TO ENSURE THAT CONTROL DEVICES,COMPONENTS,EQUIPMENT 1. EXTERIOR FLAT WORK: FIXTURE IMMEDIATELY ADJACENT TO THE JOINT. HVAC-BID PROCEDURE AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND a. 4"THICK UN-REINFORCED CONCRETE SLAB WITH AIR-INTRAINMENT OVER 4'COMPACTED CRUSHED 11.INSTALL TWELVE GAUGE VERTICAL HANGER WIRE TIES 4 FT ON CENTER WITH THREE TIGHT TURNS AROUND 1. FOR BIDDING PURPOSES,THE HVAC CONTRACTOR WILL ASSUME THAT EXISTING HVAC EQUIPMENT IS IN SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE I- CK ROCK(3/4 MINUS). THEMSELVES WITHIN THREE INCHES.INSTALL PLUMB WITHIN 1:6 UNLESS COUNTER SLOPING WIRES ARE PROPER WORKING ORDER. IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. H z 111-11 PROVIDED.CONNECTIONS AT SUPPORTING STRUCTURE TO CARRY NOT LESS THAN 100 LBS.EACH TERMINAL r/� END SHALL BE SUPPORTED WITHIN 8 INCHES OF EACH W15.REMOVE ALL UNUSED DATA AND POWER BOXES AND INFILL WITH GYP BOARD. EXCEPTION-UNUSED DATA ALL. 2. INVENTORY EXISTING H.V.A.C.ROOFTOP UNITS AND SUBMIT TO ARCHITECT A CONDITIONS REPORT OF EACH v J Q W o b. CONTROL JOINTS 5'O.C.MAX,EXPANSION JOINTS 20'O.C.OR AS SHOWN ON PLANS. BOXES UNDER WINDOW SILLS TO REMAIN. ALL BLANK COVER PLATES TO BE BUILDING STANDARD FINISH. c. BROOM FINISH WITH TOOLED EDGE EACH SIDE. 12.PROVIDE LATERAL-FORCE BRACING AT GRID MAIN WITH RIGID VERTICAL STRUTS TWELVE FEET ON CENTER UNIT U .47 07 00 00 THERMAL& MOISTURE PROTECTION 16.REMOVE ALL UNUSED LOW VOLTAGE WIRING(TELEPHONE AND DATA)FROM THE RECEPTACLE TO THE D [n EACH WAY BEGINNING WITHIN SIX FEET OF PERIMETER EDGE. 3. LIST TONNAGE OF EACH UNIT. 0 DISTRIBUTION BOARD. LEAVE PULL STRINGS FROM THE BOX TO THE SPACE ABOVE THE CEILING. A SECTION Q 2 ,:, R 1. REPLACE ALL MISSING AND DAMAGED ROOF AND WALL INSULATION ABOVE THE CEILING GRID. 13.INSTALL 12 GAUGE SEISMIC SPLAY WIRE TO THE MAIN BEAM WITHIN 2 INCHES OF EACH VERTICAL STRUT. HVAC-DESIGN PROCEDURE OF THE EXISITNG LOW VOLTAGE WIRE MAY BE LEFT IN LIEU OF A PULL STRING < Z 6- WIRES TO BE ARRAYED 90 DEGREES FROM EACH OTHER AND AT AN ANGEL NOT EXCEEDING 45 DEGREES 1. USE EXISTING ANDIOR NEW EQUIPMENT TO DESIGN MECHANICAL H.V.A.C.SYSTEM PER DESIGN STANDARDS OFFICE LIGHTING Uj Q 2. PROVIDE NEW ROOF INSULATION TO MATCH EXISTING AT ABANDONED MECHANICAL UNITS. FROM THE PLANE OF THE CEILING.ATTACHE SPLAY WIRES TO GRID AND TO THE STRUCTURE IN SUCH A LISTED BELOW. LF" - - n _ 3. AT ALL UN-USED EXISTING ROOF PENETRATIONS, REMOVE EQUIPMENT AND REPAIR ROOF SYSTEM. MANNER THAT THEY CAN SUPPORT A MINIMUM DESIGN LOAD OF 200 LBS OR THE ACTUAL DESIGN LOAD,WITH 1. OFFICE LIGHT FIXTURES: LITHONIA_ LED FIXTURE.2BLT2 40L ADP MVOLT EZ1 LP835. _fir CO IY 0 A SAFETY FACTOR OF 2,WHICHEVER IS GREATER. 2. PRIOR TO AWARD OF CONSTRUCTION CONTRACT, H.V.A.C.CONTRACTOR SHALL SUBMIT TO ARCHITECT FOR O 08 10 00 DOORS AND WINDOWS REVIEW AND APPROVAL A FULL DESIGN SCHEMATIC FOR THE TENANT SPACE INCLUDING BOTH 2. REST ROOM-WALL MOUNTED LIGHT FIXTURE-PEERLESS CERRA WALL LED,CRW7L LLP 4FT MSL4 80CRI 35K LL. U = Cr) p o 14.VERTICAL STRUTS TO BE POSITIVELY ATTACHED TO THE SUSPENSION SYSTEM AND THE STRUCTURE ABOVE. NEW/RENOVATED WORK AND SYSTEMS UNTOUCHED BY THE TENANT IMPROVEMENT AS APPLICABLE. 1900LMF DARK ZT 120 SCT C210. w C6 m Q 1. RE-USE EXISTING DOORS AND FRAMES WHERE POSSIBLE 15.USE ARMSTRONG BERC2 CLIPS TO SATISFY SEISMIC WALL CONNECTION REQUIREMENTS.SEE DETAIL. INCLUDE THE FOLLOWING: 3. OFFICE EGRESS LIGHTING: ISOLITE MINI GENIE SERIES LED VERSION LMIGN NM SQ-CEILING AND WALL U = r2 CO J 2. APPROVED DOOR,FRAME,AND HARDWARE SUPPLIERS INCLUDE: MOUNT. SEE PLAN FOR EGRESS PATH. USE OF ISOLITE INVERTER AS ALTERNATE TO BATTERY IS Q ~ ' F- 16.INSTALL SPREADER BARS AT TERMINAL ENDS OF MAIN RUNNERS AND CROSS MEMBERS AT UN-ATTACHED a. DUCTING AND SIZES Q� Q N O a. BAXTER AND FLAMING. (503)225-04136 EDGES.SPREADER BARS ARE NOT REQUIRED IF A 90 DEGREE INTERSECTING CROSS OR MAIN IS WITHIN 8 ACCEPTABLE. b. SUPPLY AND RETURN LOCATIONS AND CFM AT EACH GRILL OR DIFUSER (nCL � Q r� d b. D&D DOOR (503)205 5533 INCHES OF THE PERIMETER WALL. 4. LIGHT SWITCHES:ACUITY CONTROLS PRE SET ALL PRIVATE OFFICE AND CONFERENCE ROOM SWITCHES TO 17.IN EXISTING SPACES REPLACE WATER STAINED OR DAMAGED TILES. c. ROOF EQUIPMENT, SIZES AND LOCATIONS "VACANCY"AND TO TURN ON AT LAST DIM LEVEL. c. BENSON INDUSTRIES (503)907-2200 18.TUNE UP GRID SYSTEM TO WITHIN PLUS OR MINUS 0.5 INCHES OF LEVEL. d. UNITS REQUIRING DUCTED SMOKE DETECTION a. WALL SWITCH WITH OCCUPANCY SENSOR AND DIMMING-USE WSXD REVISION d. GRANT SUPPLY (360)887-0647e. THERMOSTAT LOCATIONS AND ZONE/UNIT ASSOCIATED THEREWITH b. WALL SWITCH WITH DIMMING AND CEILING MOUNTED OCCUPANCY SENSOR-USE SPOD 3. DOOR AND RECITE FRAMES SHALL BE TIMELY OR APPROVED. SUBMITTAL REQUIRED PRIOR TO ORDERING 19.BENT OR DAMAGED T-BARS TO BE REPLACED. MATERIAL. NEW FRAMES TO BE FACTORY FINISH CUSTOM COLOR. 20.REPAIR HOLES IN GRID FROM REMOVED WALLS. USE OF ARMSTRONG"BP ES-4"EXPANSION SLEEVE f. ANY SUPPLEMENTAL EXHAUST FANS OR SPECIAL SYSTEMS 32 00 00 EXTERIOR IMPROVEMENTS 4. FIELD VERIFY EXISTING DOOR, FRAME AND HARDWARE FINISH PRIOR TO ORDERING. ALL NEW DOORS, ACCEPTABLE. g. ZONE DIAGRAM PRIOR TO ANY EXTERIOR EXCAVATION OR BORING,GENERAL CONTRACTOR SHALL OBTAIN AN UNDERGROUND 1. FRAMES AND HARDWARE TO MATCH EXISTING BUILDING STANDARDS. HVAC DESIGN STANDARDS UTILITY LOCATE. 2. 5. ALL INTERIOR DOORS SHALL BE SOLID CORE WOOD UNLESS NOTED OTHERWISE. 09 65 19 RESILIENT FLOORING -VINYL COMPOSITION TILE THE FOLLOWING ARE MINIMUM DESIGN STANDARDS: 6. DOOR HARDWARE SHALL BE SCHLAGE AL SATURN OR D RHODES SERIES U.N.O. 1. FINISH FLOORING TO EXTEND UNDER CASEWORK. 1. 350 SQUARE FOOT PER TON (UNLESS OTHERWISE APPROVED IN WRITING BY PACTRUST). 3. 7. ALL DOOR HARDWARE SHALL BE INSTALLED WITH A 2 314"BACKSET. 2. INSTALL TILES IN 1/3 ASHLER TURN PATTERN. 2. ADDRESS LOADS BY SPECIFIC LOCATION AND USE,AS WELL AS CRITERIA PROVIDED TO PACTRUST BY TENANT PRIOR TO CONSTRUCTION: 4 8. DOOR FINISH SUBMITTAL:CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR DOOR FRAMES,DOOR 09 91 23 PAINTING HARDWARE AND DOORS AS WELL AS A CONTROL SAMPLE OF THE FINISHED DOOR SKIN W/STAIN AND FINISH INTERIOR: a. EXTERIOR EXPOSURE AREAS 5 APPLIED(IF NEW DOORS ARE BEING PROVIDED). BEFORE FINISHING OF DOORS IS COMMENCED ARCHITECT b. INTERIOR AREAS,SIZE AND USE SHALL APPROVE CONTROL SAMPLE. FINISHED PRODUCT IS SUBJECT TO REJECTION BY ARCHITECT IF THIS 1. WALLS: PROCESS IS NOT FULLY ADHERED TO AND FIELD PRODUCT DOES NOT MATCH THE APPROVED CONTROL a. PRIME NEW DRYWALL WITH MILLER'S HIGH-BUILD"SUPER SEAL"PRIMER. C. CONFERENCE/TRAINING ROOMS 6. SAMPLE. d. COMPUTER/SERVER AND TELEPHONE ROOMS TO HAVE PROVISION FOR LOW AMBIENT OPERATION 9. ALL INTERIOR GLAZING SHALL BE TEMPERED. b. NEW AND EXISTING DRYWALL TO BE FINISHED TO ACHIEVE UNIFORM COVERAGE WITH MILLER'S AND 24-HOUR USE.VERIFY NEED FOR A SEPARATE SPLIT SYSTEM TO MAINTAIN TEMPERATURE. 7. 120-4-XX WITH A TIGHT ROLLER STIPPLE FINISH. RESTROOM FINISHES TO BE MILLER'S 170-5-XX S/G 10.DEAD BOLT LOCKS AT NEW EXTERIOR DOORS TO BE INSTALLED WITH A SCHLAGE MORTISE DOUBLE LATEX ENAMEL. 3. SYSTEM DESIGN CRITERIA-SIZE ZONES FOR 3-5 TON UNITS BASED ON USE&EXPOSURE CRITERIA. 8. CYLINDER 20-013C "C'KEYWAY;SOLID BRASS;WITH ADAMS-RITE CAM AND COMPRESSION RING 1 1/8"LENGTH 2. DOORS AND FRAMES: PACKAGED OR SPLIT SYSTEM EQUIPMENT GREATER THAN 5 TONS SHALL BE SPLIT INTO MULTIPLE ZONES. WITH HARDENED CYLINDER GUARD RING KEEDEX K-24. FINISH TO MATCH BUILDING STANDARD. VAV OR WATER SOURCE HEAT PUMP SYSTEMS GREATER THAN 3 TONS SHALL BE SPLIT INTO MULTIPLE 11.PATCH AND REPAIR ALL HOLES OR DAMAGE TO EXISTING STORE FRONT WINDOWS AND DOORS.TOUCH UP a. NEW HOLLOW METAL-PRIME,SAND,AND FINISH WITH TWO COATS OF SEMI-GLOSS OIL.SPRAY OR ZONES. FINISH FOR AS NEW LOOK. ROLLED APPLICATION. 4. ALL ENCLOSED ROOMS OR OFFICES TO HAVE DUCTED SUPPLY&RETURN GRILLES. DRAWN BY: 12.TOUCH UP ALL EXISTING INTERIOR DOORS AND FRAMES FOR AS NEW LOOK. b. EXISTING HOLLOW METAL-SAND, FILL IMPERFECTIONS WITH BONDO,SAND AND PRIME PATCHES WITH 5. VACANT SPACE SHALL HAVE DEDICATED GAS SERVICE FOR FUTURE BUILD-OUT OR FREEZE PROTECTION. MWN ALKYD PRIMER,AND FINISH WITH SEMI-GLOSS OIL ENAMEL.SPRAY OR ROLLED APPLICATION c. WOOD-PRIME WITH ALKYD OIL UNDER-COATER,SAND,FILL ALL FASTENING HOLES WITH PAINTER'S 6TONS SHALLUNITS: LENNOHA,TRANE,VE SPECIAOL WRITTEN APPROVAL FROM PACRK OR CARRIER-7 1/2-TONIMUM TNIT SIZE. ANY UNIT IN EXCESS OF 7 1/2 DATE: $1171201$ 08 43 13 ALUMINUM STOREFRONT DOORS AND WINDOWS PUTTY,CAULK ALL CRACKS IN CASINGS AND BETWEEN JAMBS AND WALLS USING DAP LATEX CAULK, 1. DOOR/WINDOW FRAMES:2"x 4 112"OS GLAZED. AND FINISH WITH SATIN OIL ENAMEL. 7. HVAC UNITS EQUAL TO OR GREATER THAN 5-TONS TO HAVE DUCT SMOKE DETECTORS AND BE CONNECTED PERMIT/BID SET d. WOOD-STAIN,SEAL AS REQUIRED,AND VARNISH WITH SATIN VARNISH. TO A MONITORING STATION WITHIN THE BUILDING. 2. DOORS: 1 3/4"X 3 1/2"TOP RAIL AND STILES AND 1 3/4"X 10"BOTTOM RAII,SQUARE GLAZING STOPS. 8. ROOF TOP UNITS SHALL BE PLACED 24'MINIMUM FROM ROOF EDGE TO CENTER OF UNIT. MULTIPLE UNITS 3. DOOR HARDWARE: DEAD BOLT LOCKS AT NEW EXTERIOR DOORS TO BE INSTALLED WITH A SCHLAGE 3. CEILINGS: SHALL BE PLACED SYMMETRICALLY IN A LINE BASED ON LOAD CALCULATIONS BY STRUCTURAL ENGINEER. MORTISE DOUBLE CYLINDER 20-013C "C'KEYWAY;SOLID BRASS;WITH ADAMS-RITE CAM AND COMPRESSION a. EXISTING GYP BOARD/PLASTER-SAND,SPACKLE ALL IMPERFECTIONS,SPOT PRIME AND FINISH TO 9, CURBS: 14"HIGH CURBS. ASSEMBLED AND LEVELED TO ROOF,ANCHORED TO STRUCTURAL MEMBERS RING 1 118"LENGTH WITH HARDENED CYLINDER GUARD RING KEEDEX K-24. GEAR HINGES. FINISH TO MATCH ACHIEVE UNIFORM COVERAGE WITH MILLER'S 6200 OR 4480. BELOW ROOFING. BUILDING STANDARD. b. NEW GYP BOARD/PLASTER -PRIME WITH SUPER SEAL AND FINISH TO ACHIEVE UNIFORM COVERAGE 4. APPROVED DOOR,FRAME,AND HARDWARE MANUFACTURERS INCLUDE: WITH MILLER'S 6200 OR 4480. a. PROFESSIONALLY ROOF IN ALL CURBS AND PENETRATIONS BY PACTRUST APPROVED ROOF CONTRACTOR. SEE DIVISION 1 GENERAL NOTES THIS PAGE. a. CASCADE ALUMINUM 4. GENERAL NOTES: b. UNIT MUST BE LEVEL,SEALED WITH NO AIR LEAKS AND COUNTER FLASHED. b. KAWNEER a. KEEP ALL HARDWARE,HINGES,AND DOOR KNOBS CLEAN OF ALL PAINT SPLATTERS,DRIPS, OR ROLLER c. CONDENSATE MUST BE TRAPPED AT UNIT. A- 1 c. US ALUMINUM SPRAY. 5. FINISH: CLASS I DARK BRONZE ANODIZED FINISH(MATCH EXISTING),0.7 MILS THICK b. ALL SURFACES TO BE SANDED BETWEEN COATS, PRIOR TO INSTALLATION OF NEXT COAT. 10.SEISMICALLY ATTACH UNIT TO CURB IN CODE-APPROVED METHOD. 11.ALL GAS PIPING SHALL BE STANDARD BLACK STEEL PIPE W/SUPPORTS PER CODE. PIPING SHALL BE RUN GENERAL NOTES - DEMOcc�<c�E� 4, y A. IT SHALL BE THE CONTRACTORS AND/OR THE �J MICHAEL /14 SUBCONTRACTOR'S RESPONSIBILITY TO VERIFY ALL W WIRE THWANG rrt C) DIMENSIONS, DETAILS, AND JOB SITE CONDITIONS PRIOR —I • TO PROCEEDING WITH THE WORK, AND REPORT ANY • DISCREPANCIES TO THE ARCHITECT BEFORE STARTING ��► PORTLAND,OREGON CONSTRUCTION. 17 5851 t5 AREA OF OF p$ E WORK 1 B. REFER TO SHEET A-5 FOR WALL TYPES 0 0 ---- 3 1 C. REFER TO SHEET A-6 FOR FINISH SCHEDULES. PROJECT# 18420 D. REFER TO SHEET A-1 FOR GENERAL PROJECT 1 SPECIFICATIONS. E. REFER TO SHEET A-4 FOR REFLECTED CEILING PLANS. Q r , F. EXISTING WINDOW BLINDS TO REMAIN. Q A tiH ii ii 1 ` i G. WALL, DOOR AND SIDELIGHTS TO BE REMOVED TO 0 I EXTENTS INDICATED. REMOVE ALL ELECTRICAL Z �� \\,=.4 CONNECTIONS AND SAFE OFF ABOVE CEILING. REMOVE Q _, IrI ALL LOW VOLTAGE CONNECTIONS AND SAFE OFF ABOVE CEILING. REMOVE ALL BRACES TO STRUCTURE. REPAIR = I ANY DAMAGE TO FLOOR CEILING AND STRUCTURE. I— _ I SALVAGE ALL DOORS, RELITES, SIDE LITES AND HARDWARE 0 I FOR REINSTALLATION IN NEW WALLS. Z I Z 8 M 1 Q � W a d' 1 < N = 1 O a'D CC o Ln I J 0 o (9 t` I Q CO z N N �umnunn.. ....inn: 1coca L Ilm ® Eii J O O OQ Lf `rLf) , _ I a o_ � I - 1r 0 KEYED NOTES - DEMO Lam_ .1 O REMOVE WALLS IN THEIR ENTIRETY AND TO 1 THE EXTENTS AS INDICATED ON THE DRAWINGS. I = I OVE OR AND IN THEIR L' ~�I' I I _ _ —17,1 O ENTIRETY.OSALVAGE FOR RE-IINSTALLATION IF APPROPRIATE. B O REMOVE (E) FLOORING. REMOVE ALL 1 EXCESS ADHESIVE FOR SMOOTH FINISH. I CONCRETE WILL BE SEALED AND EXPOSED. 4 REMOVE (E) SECTION OF STOREFRONT AS INDICATED. PREP REMAINING SYSTEM FOR ADDITION OF STOREFRONT ENTRANCE. u - 2 �_GF ___ilk._ __ j O RELOCATE EXISTING POWER FROM O �lll (LU t� 3 ELECTRICAL PANELS TO PANELS AT RESTROOMS. 7 [ii rn I L7 Z Jo E Q I \ t I � I-- - L1..1 i I t====' o P IE 0 CO - - z y ] ii 111"♦00000000f• Orr'-' 000000so1 • ,I, o°o°°°°o°°w�•►�e°e°eoe°eoe°eoeeeo s (1 �- III °°°°°°°°°°°�'o°i°i°i°i°i°i°iiiiii�, CO III eoe°eoe°e°eeeeeaeeeeeeeeeeoeeeo r- dc III r-:. oo0000. 4** 000000000 W ,,, s °o°o°o°o°o°o°o°o°o°ieo°oe°o°o°o°o°o°o°o°o°o°o°o �_ � J 4, 40 e°°oeeo°e°eoeeeeeo°eee°e°eooeeeeeeeooeoo .I �e�e . ,r.�►t�' .o�e� ee�eeCe�eA.A. C �o����00oo��e�I40tv�o�y►�o�000�000���► 0 I Cn oeoeoeeo°°°044°e ,nil►°°�eee°eee°e1• -1 I •- =°O°3 •.it-!-.414,e�`C��� -!.4.!-.`3,4,t;C�4,>, . I w ee�e�ea_ ...��.e4e��e �e�e� � I0 oeoe:��s;-•::00000000: �►;�:. •:ooe1: 1 CONSTRUCTION LEGEND Q 000�o�o�o�o�s0000000000�000�o�oo�o�� 1 0 - °°°°°°°o°o°o°o°o°o°o°o° DEMO W ♦000000000000000000000000♦ I Z z o 0000000000000000000000o e00000000000000000000000♦ ♦000000000000000000000000 1 Li o °°°°°°°°°°°°°°°°° EXISTING TO REMAIN \ U ' 0000000000000000000000000 ♦0000000000000000000000000 - eeeeeeeejejejejejeeejo°ejeee°eee°eeeeeee°1• I co o °oeoeoeoeoeoeo°o°oeo°o°o°o°ooeo°oeoeoeoeoeoeoeo�• 1 , EXISTING TO BE REMOVED n/ n W w N �o�o�o�o�o�o�o� oo�o�o�o�o�o�o�o�o���� 1 "" Q 0) oo°eoe°e°o°o°°°e°°o°°e°o°°°°°e°o°eoeoe°°°o�� DUPLEX RECEPTACLE CO _ w ♦00000000000000000000000I I 0 1H . . ♦0000000000000000000000010 +� m O oeoeoeoeooooo0000eoeeeeeee°eee�� 1 FOURPLEX RECEPTACLE O °°i°i°e°i°i°i°oii°i°i°i°i°iii° i I 0� U C ' z ♦oe0000000000000000000000 -� DEDICATED OUTLET LU C6 Q oe°oo°oe°oeo°°°e°°°°°°° 1 v Q c W c, ♦000000000000000000000000• ♦00000000000000000000001► EXISTING ELECTRICAL TO REMAIN Q ♦000000000000000000000000♦ U o s°i°i°i°i°i°i°i°i°i°i°i°i°i°i°i°i °o°°i°o!� I a N o °•°eeeeeeeeell+�ee•°e1��ee°°eee°e°e°ee°o��►O 0 1 FLUSH MOUNT FLOOR MONUMENT �- ti °°°°e°e°0.,,���•o°�,�J1ro�,Ooooooooo0� 1 W/POWER AND DATA oo�•�o�•�e°°0�°eeeee��e�•��,%Aooe'�� _ (A 1 ELECTRICAL PANEL REVISION ♦o3SyootTC7?tCy��i000'►-1 �- - r �'- ejejejeje°eeejej`�eejejll ,°°ee°j°ej!�°e!jll,� r 6 ' eeeeeeeee°°e�eeet?�1reeeeeeeeeeeeee°eee�eee°Ifi��1►� 1\\ II I POWER J-BOX, 1 CIRCUIT FOR EACH oeoeo°o°o°o°oeoeoeQ►�o111Le°eee°e°eee°e°eee°e°v���0$4-- ._II I 5 WORK STATIONS MIN. 1. ♦000000000� . �00000000000�O, ♦0000000000+h0000000000001►� ♦0000000000� �000000000000 � oiiiiii°i°°i°oT�°°o°i°i°i°i°i°i°i°i°iei►4 o°e°e°e°e°e°e°°°°°°°°°i+1i°e°o°e°e°e°o°o°o°e°°°i'►l 1 2. o°o°°°°o°o°o°o°o°o°4. -:o°i°i°iiiiiiiioff 0 I 3. ♦00.000000•*�00000000000N3 ii°i°i°° Ls °°°°°°° w� ♦000000000o i�00000s00000/ 4 1 4. e�������0, 1 *oe°e°e°e°e°ee°eek 5 D1 I ii , ii II U U II 1- III 6. I 7. I 8. I I 1 DRAWN BY: I MWN 1 DATE: 8/17/2018 1 1 PERMIT/BID SET 1 I AREA OF WORK 1 FLOOR PLAN - DEMO ze9 Am2 A-2 SCALE 1/8"=1'-0" GENERAL NOTES (c,*D 4, , A. IT SHALL BE THE CONTRACTOR;S AND/OR THE ��'J MICHAEL SUBCONTRACTOR'S RESPONSIBILITY TO VERIFY ALL W WIRE THWANG 01C) DIMENSIONS, DETAILS, AND JOB SITE CONDITIONS PRIOR --1 TO PROCEEDING WITH THE WORK,AND REPORT ANY (13 PORTLAND,OREGON DISCREPANCIES TO THE ARCHITECT BEFORE STARTING • 5851 CONSTRUCTION. '9,` �� ` AREA OF OF O� _.....„, E WORK 1 B. REFER TO SHEET A-5 FOR WALL TYPES , r7---- , \ 1 I I C. REFER TO SHEET A-6 FOR FINISH SCHEDULES. D. REFER TO SHEET A-1 FOR GENERAL PROJECT PROJECT# 18420 i 1 0 41 i SPECIFICATIONS. IE. REFER TO SHEET A-4 FOR REFLECTED CEILING PLANS. Q (--- I I F. EXISTING WINDOW BLINDS TO REMAIN. Q N.._ r Ap A cp I . • I COATS z 11251 I Q t MED MTG �� �II I H 11071 0 ,,. �,� % I O 22'-6'- 12'-9' o � -''An'�j CPT-1(� I ��' 1 13'-3'x 1 0-2' ;% y CPT-1(E) I -b' z O �c� O 0 ig 1 Q OA A C 1 ALIGN J 4'-8" II1. Y W J HALL ' .1.o I ¢ti rep bo 6 37,11081 x1 �-9" 7'10'x a'2' I cc 2 ti r �CPT-1(9 CPT-1(E) I J 0 p co ti T I I (ALIGN Di Ill LLI I I I L____011 �JI 1 C)Q N N 1 I = or r Z f/�J o 0 _ _L_ o I v DIMENSIONS FOR ,_CL d U_ LOCATION OF POWER 11 1 11 PHONE I KEYED NOTES `Y' AND DATA OUTLETS. • 10'-0'x 7'-6' _1 ®I CPT-1 = 1 ODOOR LOCKS- ELECTRIFIED PANIC ( [ j = HARDWARE ADDED TO STOREFRONT ENTRY I DOORS, TENANT TO SUPPLY AND INSTALL -. J --+ --1 ® ID S g 1 LOW VOLTAGE AND CARD READER. ,, QUIET I 2 NEW STOREFRONT DOORS TO MATCH EXISTING m - P 11121 I o O STOREFRONT SYSTEM FINISH. ELECTRIFIED OPEN OFFICE 10'-0°x 7'-6" ng LOCKSET ADDED TO STOREFRONT,TENANT TO p 3 CPT-1(� '� - AND INSTALL LOW VOLTAGE AND CARD - 12_2.x 3T-5" — � VIII IDA —� CPT-1(� GF III —1 READER. - IC•r_---��-- -- I— 111 ,I,;111 0 + - SiGFi �FRID�,EI I 3 ELECTRIFIED LOCKSET ADDED TO SERVER ROOM, TENANT TO SUPPLY AND INSTALL LOW VOLTAGE I MEDoMTG. _L- -L A AND CARD READER. 1.4 g O I O NEW, TENANT PROVIDE RANGE.CONTRACTOR TO 13'-0"x 24'-7" N CPT 1(E) 4 BREAK ROOM 4 PROVIDE AND INSTALL THE EXHAUST HOOD. n 11131 I PROVIDE ELECTRICAL AND EXHAUST CONNECTIONS ' _I O T � 4 17'-11'x 16-s° I PER SPECIFICATIONS. VCT-1 I 5 DEDICATED COOLING FOR SERVER ROOM.SEE ir, PTEI DETAIL 13/A-5. ALIGN 10.-2" 2'-s" 10'-1" in I NEW POWER AND DATA J-BOX FOR TENANT SYSTEM y y / CPT E VCT O FURNITURE REQUIREMENTS. Ai,j//////���, CPT(E) N '•vv:v_..ii, . - wZ:r.���r.�:rr.���lll�r.�:�:��r.�,.1 PHONE I Q7 NEW CONCRETE SIDEWALK. o - 'r--, 1114 V rn I7f/f77//L. . LOBBY .I I _ s'-a x 10'-0 1 z U 11001 tiii °' `' III (E) 1 Q8 NEW PARTIAL HEIGHT WALL. SEE DETAIL 10/A-5 z $ I-- ALIGN 14'-0'x 23'-0' �° I *k ... CPT-1(E) I I II) I 9 ELECTRIFIED LOCKSET ADDED TO STOREFRONT, Ct ;:; O ® I TENANT TO SUPPLY AND INSTALL LOW VOLTAGE scQ. il_l CL VIII AND CARD READER. SM MTG CIRC OPENOFFICEL- 1; I 0 ''• 101 Cu- w 3' I I I EXISTING ELECTRICAL OUTLET UP TO 42 MOVE �/ C� 1; 11031 32'11 x 3s'2 O 10 A.F.F. LL v ^ 11'-1'x 14'-11" a 18'-1•x 4'-2' a CPT-1(E) • I J _eri CPT 1(E) c� _ 'CPT-1 II- 111 I CO 1 :ti_ - in r 0 T-v I Q o O WOMENS Q O1 I -- 0 I z ..,.• . .'�; . I � 1 � ��•.�•.•�•...••.•.wa• - 105IIIIIIILA 11 \ I I I Q , , v E ALIGN J --= 41 �[C :::- 1 1 �:; © /�1 jwil Ft _ SERVER 7Cl [�' �t..:F. 11241 I I rn n nI J ;' 1 10'-10"x 12'-s' 1 - - O SC p O �p ICO 3 e �; .::>, p ❑ IIIA 6'-6" O: O w- PT-5 M I ° PY i �' I I w •:...................... © 1120• 6OFFICE I HALL C, ,'x 5'-0' b < PT-1(E) 0 116I SC CPT E) 1 LU ►® 1123 Cn ALIGN 10CPTx1( 0' I 1 i* t 29CP x 2z'-,1' in • Z O °�' OPEN OFFICE 1 I CI) Q O .. .:.. ..:..:.. ..:..:... .:... 1191 Lu 4 30-4"x 2T-10' F. •:€�•:•:��•:�•:�•:•:•�•:��w:•:�w C..)® CPT-1(E) OA I . > CO a d- \ • I 0 Lu ti in - - -0- -0-m-0- 10'-2" STORAGE 1 r I 8- - _ !------ I 2 Q a63122a',o° / ® ® ' + + 11170 4--+ m O SM MTG F— Sc • �W� CV O�w �- �- 1 1 ,.nLL • 13CPTX112-0. I Q (E� I W CCT D LRGMTG °' F°� I U Q Ce CO a CD Qw°o -11211 8¢O --n— -0—T-0-T0)- 1 22'-11'x 28'-8' ® Id Fi. dU)CPT-1 Oa I I - I Eo p ti 0 ® + + .:. . .: .: ..: . . . . . I REVISION PA I --0--r-f-T-0-- N SM MTG I 1. ,a'_a 182'_d I CONSTRUCTION LEGEND 2. A0 -� ----am II 1 ---i--I CPT-1(E) i; ALIGN I 3. �_ _ _� ;, I ® EXISTING TO REMAIN 4. .4131® NEW STANDARD WALL WITH INS. II I11V V111 0111 I ® +v BV 5. D -- — - ii "f _ riiiii�iiiiinink NEW STANDARD WALL NO INS. DUPLEX RECEPTACLE 6. iD FOURPLEX RECEPTACLE 7. OUTLET TO REMAIN 8. D=Q DEDICATED OUTLET TO REMAIN ' DRAWN BY: V EXISTING DATA TO REMAIN MWN THERMOSTAT DATE: 8/17/2018 Q SPECIAL OUTLET PERMIT/BID SET a TEL/DATA MUD RING WITH PULL STRING \ AREA OF e ELECTRICAL PANEL E WORK Q POWER J-BOX Q FLUSH MOUNT FLOOR MONUMENT W/POWER AND DATA 0 1 FLOOR PLAN - NEW ZA. 3 ED A-3 SCALE 1/8" = 1'-0" GENERAL NOTES <'*D 48c A. IT SHALL BE THE CONTRACTOR;S AND/OR THE D MICHAEL � WIRE THWANG SUBCONTRACTOR'S RESPONSIBILITY TO VERIFY ALL 1-1.1 n DIMENSIONS, DETAILS, AND JOB SITE CONDITIONS PRIOR —I TO PROCEEDING WITH THE WORK, AND REPORT ANY • DISCREPANCIES TO THE ARCHITECT BEFORE STARTING ��► PORTLAND,OREGON t. CONSTRUCTION. IN 5851 !� AREA OF F OF 0 ‘ 4C WORK 1 B. REFER TO SHEET A-5 FOR WALL TYPES 1 2 1 C. REFER TO SHEET A-6 FOR FINISH SCHEDULES. PROJECT# 18420 I 1� \3 4 I D. REFER TO SHEET A-1 FOR GENERAL PROJECT SPECIFICATIONS. I E. REFER TO SHEET A-4 FOR REFLECTED CEILING PLANS. F. EXISTING WINDOW BLINDS TO REMAIN. Q A I II G. ADJUST FIRE SPRINKLERS AS NECESSARY FOR NEW ROOM ■■■I ---- -r LAYOUT. z E` 1 '■■ I I ` — H. ADJUST HAVE SUPPLY AND RETURNS AS REQUIRED FOR NEW s u11 1111■ m \ ROOM LAYOUTS. z X ;��I ® I o JI!II 1 11E1111 ° I Q 41 =_ I LIJ ' 11M111 El r, 1 % I Q N iiimo. , -5 oti ■■■I` I J Cl p c9 ti a ■■■■■ 6O I Q w`r'Z n- CD r — Z v)J MM O ----; I _ U c,,O = x k . x . . ir=4.,..-- ' ;III .0 o?A., , n Y AI\ 11 1 I I�B ! �/ ■■. - - -1 f 1 _Ki IT Y • IF4I - la I A A A A . 1 I - • x •• 0 A • i 1 1 Iv F _ I : 0 o T T1 IN # � 1 V I , I z C/ — s F int ® I W CL I -J X I m • • A 1 ct o el r, N I CQ m fYi 4,, . --,.. ..... 1111.11% 4 A. t ...vlsi. .M . ' 11 fjok. 4v't P:l'i . 0 :ii• I I CD smo ■1 , ® ' z • " % ■11�, 7 1 w 1 CONSTRUCTION C ) Ali ® 1 CEILING NEW W I ,. II A _� I , ' �� ■ _ 1 (N)2 X 2 LED.FIXTURE 1Ill I H LITHONIA 2BLT,CURVED LENS Q I � (E)2 X 2 LED.FIXTURE TO BE MOVED OR REMOVED. H Z W VV 11 ' • • _I I .._ i I LEITHONIA 2BLT,CURVED LENS TO REMAIN XTURE V! > LLJ C3 C -- /� , � k t 0 (E)RECESSED LED LIGHT � Q w � cc, _ � � Z - -ti -�F� I (E)WALL MOUNTED VANITY LIGHT (7) = Ct X X X X I (N)SUPPLY DIFFUSER V _�__+ m ? O LL U moo 1 (N)RETURN DUCT W co S) J •Yli . 1 a 0 (..) -1- r= • Fi I OT THERMOSTAT du) EL I— ¢ N O EXHAUST FAN REVISION • I 2X2 DE / J / I / 1 TILE • SPRINKLER HEAD /R 's /fit i . /R /1� 1 1. I 8 EXIT SIGN(LED RED) 2. • I O SMOKE DETECTOR 3. I . I � RECESSED CEILING EMERGENCY LIGHTS 4. ILIL�� _ r ' •I_` ' x• 1 I 0 CEILING MOUNTED MOTION SENSOR 5 D 1 1 1 1 ,r ® WALL MOUNTED LIGHT SWITCH WITH MOTION 6 SENSOR AND DIMMING CONTROL. I 7. I INDICATES COMMON PATH OF TRAVEL REQUIREING EMERGENCY 8. I LIGHTING EQUAL TO 1-FOOT CANDLE. AREA OF J 2 X 2 SUSPENDED CEILING SYSTEM: E - - - - FULL 24" DRAWN BY: WORK ,111 TILE THIS SECTION ATTACHED EDGE MWN N■■■' SEISMIC EXPANSION JOINTS M 4//M M DATE: 8/17/2018 ■■■■■ UNATTACHED EDGE IEEE. PERMIT/BID SET GRID MAIN ■■■■■ A-4 i REFLECTED CEILING PLAN A-5 z� SCALE 1/8" = 1'-O" FLOOR AND/OR ROOF STRUCTURE ( r1) A/JC r 1!4'FILLER FOR 20 GA 3 5/8"METAL STUD BRACING TO ROOF ARMSTRONG BERC2 CLIP(AS ALTERNATE MEANS OF CONSTRUCTION \� MICHAEL 90"CONDITION STRUCTURE AT 10'0"OC TO BUILDING STRUCTURE FOR THIS PROJECT.) C7 WIRE THWANG ABOVE FOR WALLS LONGER THAN 12'-0"WITHOUT - ADDITIONAL HANGERS AT ALL MAINS WITHIN 8"OF THE PERIMETER I o LL1 C-) INTERSECTING WALLS. FASTEN EACH END WITH(1)#8 , APPROVED VERTLCAL STRUT AT 12'-0"O.C. EA.WAY BEGINiNG WITHIN 0 SHEET METAL SCREW WHERE REQUIRED �I o � �1 6' 0"OF THE PERIMETER OF EACH CEILING SECTION.SEE STRUT DETAIL LITE KIT WHERE SPECIFIED o FRAME TO MATCH DOOR PORTLAND,OREGON STRUTS AT FIXTED EDGES NOT ATTACHED TO THE BUILDING TO 5$51 C`0 0 , ---- - TYPICAL STUD HAVE 4 WAY LATERAL BRACING FROM THE MAIN RUNNER TO THE PROVIDE HC SIGNAGE FOR ALL NEW �] gi4S'Eolhillikn. SUSPENDED CEILING BUILDING STRUCTURE ABOVE. / 6" '6", ® AND EXISTING HO RR'S KROY Qi 2'-0" � � 2" #2835207 BLACK(MEN)KROY CP BLOCKING TYPICAL AT FASTENING POINTS g • #2835209 BLACK(WOMEN) PROJECT# 18420 --�- r 0 00 ,, TYPICAL TRACK • o i let 3 5/8"MTL.STUDS 24"O.C. z N °E" (IN REMODELS SIZE STUDS TO ALLOW REUSE INSTALL STUDS WITH SAME o a / ADDITIONAL SWITCH GANG OF BLDG.STD.DOORS AND FRAMES) DIMENSION(10"MIN.)FOR • o r� LOCATION j BRIDGING ALIGNMENT ti �, 5/8"GYP.BRD.BOTH SIDES )8" CROSS MEMBERS BETWEEN MAIN I a) 1/ C- Q rn ,r' CENTER LINE OF STUD MAX RUNNERS _ -- •c. m • ill Li Q 6'-0"MAX MAIN RUNNERS AT 4'-0"O.C. 1 SUPPORT WITH#12 WIRE AT 4'-0"O.C. ` (� ,,i: (c'*0 At) FINISHSCHEDULE FINISH MATERIALS ALL FINISHES MUST BE SUBMITTED TO ARCHITECT PRIOR TO INSTALLATION ABBREVIATIONS ---....--a� WALLS MICHAEL BROADLOOM CARPET: CB CERAMIC TILE BASE W WIRE THWANG RM# NAME FLR BASE CEILING CLG. HT. REMARKS RM# CFCI CONTRACTOR FURNISHED, CONTRACTOR INSTALLED n - NORTH EAST SOUTH WEST CPT-1 MOHAWK GROUP PTR- BROADLOOM BC3751 BQ375-358 RESHAPED FELT, DIRECT GLUE --{ EXISTING CARPET USE MOHAWK BRAND NUBROADLOK PREMIUM ADHESIVE ONLY CPT-# CARPET 100 LOBBY CPT-1 (E) RF PT-1 PT-1 PT-4 PT-1 ' SAT(E) 9-0 -- 100 CT CERAMIC TILE cP PORTLAND,OREGON E (E) EXISTING 101 SM MTG CPT-1 (E) RF PT-1 PT-1 PT-1 PT-2 SAT(E) 9'-0" -- 101 VINYL COMPOSITION TILE9,. 5851 <I� VCT ARMSTRONG RAFFIA, 55904 SMOKE, 12"X 24"X 1/8" ETR EXISTING TO REMAIN c O �` 102 MED MTG. CPT-1 (E) RF PT-1 PT-1 PT-2 PT --1 SAT(E) 9'-0" 102 USE MOHAWK M700 ADHESIVE. (M95.0 IN HIGH MOISTURE AREAS) WC WALL COVERING `_ O 1 GWB GYPSUM WALL BOARD 103 CIRC CPT-1 (E) j RF PT-1 PT-1 PT-1 PT-1 SAT(E) 9'-0" -- 103 N (N) NEW �' WALK OFF CARPET PGWB PAINTED GYPSUM WALL BOARD PROJECT# 18420 104 MENS CT(E) CB (E) PT-1 PT-1 PT-1 PT-1 GYP (E) 91-0" (E)CT TO REMAIN 104 WOC MOHAWK GROUP TUFF STUFF II -STEP UP II -983 IRON ORE, DIRECT GLUE OTS OPEN TO STRUCTURE 105 WOMENS CT (E) CB (E) PT-1 PT-1 PT-1 PT-1 GYP (E) 9'-0" (E) CT TO REMAIN 1 EXISTING CARPET USE MOHAWK M700 ADHESIVE. (M95.0 IN HIGH MOISTURE AREAS) PL-# PLASTIC LAMINATE BASE PT-# PAINT 106 OPEN OFFICE CPT-1 (E) RF PT-1 PT-1 PT-1 PT-1 SAT(E) 9'-0" 106 RF FLEXCO 4" FLAT RUBBER BASE, 071 BLACK/BROWN,AT ALL CARPET AREAS. RC RUBBER BASE COVED 107 MED MTG CPT-1 (E) RF PT-1 PT-1 PT-2 PT-1 SAT(E) 9'-0" -- 1 RC FLEXCO 4"COVE RUBBER BASE, 071 BLACK 1 BROWN,AT ALL HARD SURFACES. RF RUBBER BASE FLAT SAT SUSPENDED ACOUSTICAL TILE 108 HALL CPT-1 (E) { RF PT-1 PT-1 PT-1 PT-1 SAT(E) 9'-0" - 108 PAINT: SC SEALED CONCRETE Q PT-1 SHERWIN WILLIAMS SW7006 EXTRA WHITE EGGSHELL SS SOLID SURFACE MATERIAL Q 109 ROOM CPT-1 (E) RF PT-1 PT-1 PT-1 PT-1 SAT(E) 91-0" -- 109 PT-2 SHERWIN WILLIAMS SW7017 DORIAN GRAY EGGSHELL VCT VINYL COMPOSITION TILE 110 PHONE CPT-1 (E) RF PT-1 PT-1 PT-4 PT-1 SAT (E) 9'-0" -- 110 PT-3 MATCH PANTONE BLUE GREEN(PMS 313) WL WOOD VENEER LAMINATE 00 __. PT-4 MATCH PANTONE DARK BLUE (PMS 2955) WW WINDOW WALL 111 PHONE CPT-1 (E) RF PT-1 PT-1 PT-5 PT-1 SAT(E) 9'-0" - 111 PT-5 MATCH PANTONE GREEN YELLOW (PMS 382) Q 112 QUIET CPT-1 (E) RF PT-1 PT-1 PT-2 PT-2 SAT(E) 9'-0" - 112 LAMINATE: 113 BREAK ROOM VCT-1 RF PT-1 PT-1 PT-3 PT-1 SAT(E) 9'-0" - 113 PL-1 FORMICA 5882-58 CITADEL WARP I- PL-2 FORMICA 6920-58 MINERAL SPA O 114 PHONE CPT-1 (E) , RF PT-1 PT-1 PT-3 PT-1 SAT(E) 9'-0" - 114 115 OPEN OFFICE ' CPT-1 (E) RF PT-1 PT-1 PT-1 PT-1 SAT (E) i 9'-O" - 115 DOORS,HHARDWARE ARE AND FRAMES 5 BRIGHT CHROME Z o 116 1 OFFICE CPT-1 (E) RF PT-1 PT-1 PT-2 PT-1 SAT (E) 9'-0" - 116 FRAMES MATCH EXISTING Q W 117 SM MTG CPT-1 (E) RF PT-1 PT-1 PT-2 PT-1 SAT(E) 9'-0" - 117 CABINET HARDWARE W 118 SM MTG CPT-1 (E) RF PT-1 PT-1 PT-2 PT-1 SAT(E) 9'-O" -- 118 HINGE: BLUM CLIP 120(CONCEALED) o-N DRAWER SLIDES : BLUM 230(3/4" EXTENSION) "- 119 OPEN OFFICE CPT-1 (E) RF PT-1 PT-1 PT-1 PT-1 SATE 9'-0" - 119 o 63 Q ( PULLS: 96 MM C-TO-C C WIRE PULLS. FINISH TO MATCH DOOR HARDWARE. ix F ti 120 MAIUCOPY CPT-1 (E) RF PT-1 PT-5 PT-1 PT-1 _ SAT(E) 9'-0" - 120 J CI 0 Cr) NT W (Op ccic 121 LRG MTG CPT-1 (E) RF PT-1 PT-1 ' PT-2 PT-1 SAT(E) 9'-0" - 121 Q z CD c 122 STORAGE SC RF PT-1 PT-1 PT-1 PT-1 SAT(E) 9'-0" - 122 I \ \ U 123 HALL CPT-1 (E) RE PT-1 PT-1 PT-1 PT-1 SAT(E) 9'-0" - 123 J 0 _,>< 124 SERVER SC RF PT-1 PT-1 PT-1 PT-1 . SAT(E) 9'-0" -- 124 DOOR SCHEDULE ADJUSTABLE m DOOR DATA FRAME DATA HARDWARE SHELVING "' Fire Rating Remarks Mark Mark Door Size Thk Core Veneer Finish Hand - - - Type Frame Depth Hardware Manufacturer Finish Function CABINET .., 100 3'-0" x 7'-0" 1 1/2" -- ALUM/GLASS -- Left -- 4 314" PUSH/PULL/CLOSER/LEVER LOCK 10, TUNE UP HARDWARE . 100 101 3'-0" x 7'-0" 1 3/4" SC WHT OAK CLEAR COAT Left TIMELY 4 3/4" PASSAGE LATCH Schlage 625 AL1OS 1 101 102 3'-0" x 7'-0" 1 3/4" SC WHT OAK CLEAR COAT Right TIMELY 4 314" i PASSAGE LATCH ETR, TUNE UP HARDWARE 102 1 107 3'-0" x 7'-0" 1 3/4" SC WHT OAK CLEAR COAT Right TIMELY 4 314" ; PASSAGE LATCH Schlage 625 ALTOS NOTE 1 - 2 SIDELITES 107 109 3'-O" x 7'-0" 1 1/2" -- ALUM/GLASS • -- Right -- 1 4 314" . PUSH/PULL/CLOSER/LEVER LOCK 10, TUNE UP HARDWARE 109 110 3'-0" x 7'-0" 1 3/4" SC WHT OAK ' CLEAR COAT Right ' TIMELY 4 3/4" PASSAGE LATCH Schlage 625 ALAOS 1 ; 110 111 3'-0" x 7'-0" 1 3/4" SC WHT OAK CLEAR COAT Right TIMELY 4 3/4" PASSAGE LATCH Schlage 625 ALTOS 1 111 N - o 112 3'-0" x 7'-0" 1 3/4" SC WHT OAK CLEAR COAT Left ' TIMELY ' 4 3/4" PRIVACY LOCK WITH INDICATOR DORMA 625 J346 -- 112 °' PLAM-2 SPLASH 114 3'-0" x 7'-0" 1 3/4" Sc WHT OAK CLEAR COAT Left I TIMELY 4 3/4" PASSAGE LATCH Schlage 625 AL1 OS 1 114 a " PLAM-2 COUNTER 0z a 116 31-0" x 71-0" 1 3/4" Sc WHT OAK CLEAR COAT Left TIMELY 4 314 PASSAGE LATCH Schlage 625 AL1OS 1 116 �, ,� „ \ 117 31-0" x 71-0" 1 3/4" SC WHT OAK CLEAR COAT Right TIMELY ' 4 314 PASSAGE LATCH Schlage 625 ALIOS 1 117 1 ItI- 1 118 3'-0" x 7'-0" 1 3/4" Sc WHT OAK CLEAR COAT Left TIMELY 4 314" PASSAGE LATCH Schlage 625 ' ALIOS 1 118 /1 1 —• \ W 0_ I- - - 1 I - \_ c 121 3'-0" x 7'-0" 1 314" SC WHT OAK CLEAR COAT Left TIMELY 4 314" PASSAGE LATCH Schlage 625 AL10S NOTE 1 - 2 SIDELITES 121 ii - -X WIRE 0 „ „ 1/2" DRAWER com- RAWER PULL, (0 r o 122 PR 3-0 x 7-0 1 -- ALUM/GLASS -- NA -- 4 3/4" PUSH/PULL/CLOSER 2,3,4,5,6,7,8,9,10 122 I \1" TYP. Q m .123 3'-0" x 7'-0" 1 3/4" SC WHT OAK CLEAR COAT Left TIMELY 4 3/4" . PASSAGE LATCH Schlage 625 AL80PD 123 I r, 124 3'-0" x 7'-0" 1 3/4" SC WHT OAK CLEAR COAT Right • TIMELY 4 3/4" PASSAGE LATCH Schlage 625 AL80PD 11 124 MELAMINE 4"WIRE, DOOR J PULL, TYP. 0 125 3'-0" x 7'-0" 1 314" SC WHT OAK CLEAR COAT Left TIMELY 4 718" PASSAGE LATCH ETR, TUNE UP HARDWARE 125 INTERIOR P LAM-1 BASE NOTES: ADJ. CABINET CO 1. 3'-O" x 7'-0" SIDELITE, TEMPERED 10. ELECTRIFIED PANIC HARDWARE ADDED TO STOREFRONT ENTRY DOORS,TENANT TO SUPPLY AND w 2. IVES DOOR HOLDER INSTALL LOW VOLTAGE AND CARD READER. - J 3. 4560 DOOR HANDLE 11. ELECTRIFIED LOCKSET ADDED TO SERVER ROOM, TENANT TO SUPPLY AND INSTALL LOW 4. FULL LITE IN DOOR, MATCH BLDG STANDARD FOR EXTERIOR DOORS. VOLTAGE AND CARD READER. -' \ CO 5. BRUSH SWEEP ON DOOR' LIJ 6. CLOSER \ \ \ 020" 3'J• 1 Q 7. FULL WEATHER SEAL AROUND DOOR 8. THRESHOLD 9. REUSE EXISITNG STOREFRONT IF POSSIBLE. 1;17 z ilj c, 1 BREAK ROOM CABINET CQ LU g A-6 SCALE 112" = 11-0" �/ Ci U Ce El LL Q z0) 31.. 3 - CONNECT HOOD }� [=fl c 0 4 4 1. /' VENTILATION TO BUILDING 41„ 1. 1„ O n - 1274" 32„ 2 EXHAUST FAN. 4 2 /l-- 3 74" 2 IL F- r= D (7) EQ CABINETS / (2) EQ CABINETS �I 38" / 434 / 38" /1/ /.dr (4) EQ CABINETS r ,!// W Ca S � z 25 I I I 67 � — a � 0_ I ' I y\ I I I REVISION II II II I I I HI II . I / / \ / \ / \ 7 \_ : ; / , I \ , I 11 . I . I / ; E \ , � / \ / \ , 1 /1� F RF 9H +I *1 F R 91 H IF R I ,I/ II II I 3 II I � / I 7 � I \ I ` 2. Zia J.SHELFI Y� ADJ. SHELF I ADJ. SHELF XI ADJ.SHELF ADJ. SHELF ADJ. �EELF � ADJ ELF i Y ADJ.� HELF iY� ADJ.SELF �4Y ADJ.SHELF �x1 PL-1 ' \ PL-1 1 I PL-1 II PL-1 I I P=1 I I PL+1 I I 'LH1 I / I i� AL 1 \ PL-1 II PL-1 E F I I I I I I r R r 1 I 1�1 \ Ii II II11 \ // 11 \ / I \ / I \ / I I Ik I II I 4. 1 \L A,i/ 11 - 1/ / I I I I I I __ 1 r I I / - II / NEW50APDISPENSER W + r ,r R __ .--1 -- AND PAPER TOWEL DISPENSER 5, PAPER TOWEL DISPENSER. ------ CO I *ROWAVE I CFCI KITCHEN RANGE EXHAUST HOOD. PL 1 NEW SINK AND FAUCET 6. _t ---- TENANT PROVIDED KITCHEN N GFI GFI _ _ _ 1 n i /� RANGE EXHAUST HOOD. - 7, (L — - - PL-2 a , J- PL-2 / 00 O O� PL 2 -'c PLAM 2 BACKSPLASH d ACROWAVE j 4 \ S. r PL-2 I PL-2 PL-2 1 PL-2 PLAM-2 COUNTER r PL-1 I1, ,r I r 1 h ( _ 1-IN , 1 _. 1 1 /I IN I I L i I — I I .� T i e I I e I I o II TN DRAWN BY: 1 - 1 I I 1 I 1I I -----<,,_ t'ir t PLAM-1 CABINET FACE AND LL t---- ' 1t � r r -I r �r--- r -I r 1r til �� Li 1 II / I 1 \ I I I � 1 ! __ 1IN I 1 I I Co I MWN =N I II 1 DISHWA4HER I I / 1 / f __ / 1 / \ I / \ I / II / \ I I / \ EDGES. I - >kA6SHF I ® 9 I I = I I ro ADJ. HELF 1 HELFI 8 ADJ SHELF • , A SHELF K ADJ.SHELF ADJ.SHELF \II/ ADJ.SHELF N 1/ DATE: 811112018 a -1 PL-f 7r PLT /� . 1PL-1 pt __ T 7 r� 1 1 GFI, D ADA 51NK/ I 1 PL 1 D 1 I I I ;� I PERMIT/BID SET I I I PL-1 I \ 1 I N. I \ k / 1 I \ - I \ / / I I I I I I = I f I 1 f i I I I 1 `� WATER 1 � ` REUSE EXISTING DISHWASHER. M � 44" 74" \ CONNECTION FOR TENANT 1„ 1„ 2, PROVIDED REFRIGRATOR. / (3) EQ CABINETS 322 35" / 2 (4) EQ CABINETS if - - 48" 1 3. / 36" 154 i 32"/ 4 66, -../ / s" iv 1(4)EQ CABINETS ,4 A- 6 (--2�BREAK ROOM CABINET 3 COPY AREA CABINETS (4-- QUIET ROOM CABINET SCALE 112" = 1'4Y (\A ,-6 SCALE 1/2" = 1'-0" \.!!k-6/SCALE 1/2" = 1-0"