Plans (381) BU P2018 - 00177 LI'S PRIME/PAY TEEL ARCHITECTS 720 NW Davis 503.221.1121 it Suite 300 503 221.2077 I) Portland OR 97209 www.Irsarchitects.com ATRIUM WEST e) it,?0,„ 3PORTLAK 1 ..:. 1 *, CIPST, MICHELE C.SWOT A 'kali • 9 3 vi OFc ` REVISED PERMIT SET 05. 24. 18 CONSULTANT: 1 PROJECT DIRECTORY PROJECT SUMMARY CODE SUMMARY (SEE EGRESS PLAN BELOW) LEGEND (SEE EGRESS PLAN BELOW) RECEIVED BUILDING MANAGER: 1. GENERAL INFORMATION: V. EMERGENCY SYSTEM STANDARDS: OCCUPANT LOAD PER SECTION 1004 17= AREA OF WORK Colliers International Gil Fitzpatrick:Gi1,Fitzpatrick@coliiers.com 44"MIN. EXIT EGRESS PATH JUN ���8 PROJECT NAME: PRIME PAY T.I. OCCUPANCY SQUARE FEET LOAD FACTOR OCC. LOAD " 851 SW 6th Avenue,Suite 1200 PROJECT ADDRESS: 9600 SW OAK ST 1. BUILDING IS FULLY SPRINKLERED (NEPA 13). MAKE CODE Portland,OR 97204 SUITE 380 MINIMUM CORRECTIONS AS REQUIRED PER NEW PLAN. B 5,619 RSF 15/100 82 B OCCUPANCY GROUP CITY OF TIGARD Telephone (503)499-0073 TIGARD, OREGON 97223 2. IN BUILDINGS EQUIPPED WITH AN EXISTING VISUAL STROBE 1X ROOM OCCUPANT LOAD PER SECTION 1004 BUILDING DIVISION MAP/TAX LOT: IS135BD00100 SYSTEM:PROVIDE CODE MINIMUM CORRECTIONS AS REQUIRED. IF A SYSTEM DOES NOT EXIST, DO NOT ADD REQUIRED EXITS PER SECTION 1015 Il. APPLICABLE CODES: ONE, (XX) ACCUMULATIVE OCCUPANT LOAD ARCHITECT: OCCUPANCY SPRINKLERED REQUIRED PROPOSED 3. PROVIDE EMERGENCY EGRESS LIGHTING FOR THE EGRESS UO UNOCCUPIED SPACE LRS Architects, Inc. Darcie McConnaha: dmcconnaha@lrsarchitects.com 2012 INTERNATIONAL BUILDING CODE(IBC) PATH IN ALL PUBLIC AND TENANT SPACES. MINIMUM B Y 2 2 2014 OREGON STRUCTURAL SPECIALTY CODE(OSSC) ADDITIONAL PERMITS REQUIRED 720 NW Davis,Suite 300 INTENSITY SHALL NOT BE LESS THAN 1 FOOTCANDLE AT EXIT SIGN w/INTEGRATED DIRECTIONAL ARROW Portland,Oregon 97209 2014 OREGON MECHANICAL SPECIALTY CODE(GMSC) FLOOR LEVEL ALONG THE ENTIRE LENGTH OF THE PATH. ® �� WHERE OCCURS ATALL EXITS, EVERY 100'1N Fire Sprinkler 2014 OREGON FIRE CODE CONNECT TO BUILDING ELECTRICAL SYSTEM. MINIMUM DISTANCE ALLOWED BETWEEN EXITS PER 1015.2.1 CORRIDORS,AND IN SPACES WHERE 2 MODES OF Telephone(503)221-1121 2014 OREGON ENERGY EFFICIENCY SPECIALTY CODE(OEESC) Fire Alarm 2014 OREGON PLUMBING SPECIALTY CODE(OPSC) 4. PROVIDE EXIT SIGNAGE. EXIT SIGNAGE SHALL BE OCCUPANCY SPRINKLERED REQUIRED PROPOSED EGRESS ARE REQUIRED PER SECTION 1011. (REFER Mechanical 2014 OREGON ELECTRICAL SPECIALTY CODE(OESC) OESC) CONNECTED TO BUILDING POWER SUPPLY WITH BATTERY TO ELECTRICAL DRAWINGS FOR MORE _-- BACK-UP FOR MIN 1-1/2 HOUR DURATION. B Y 40'-0" 41-6" INFORMATION). POCHE INDICATES "EXIT'TEXT SIDE Plumbing GENERAL CONTRACTOR; 2009 ANSI A917.1 \ 5. PROVIDE CODE MINIMUM FIRE ALARM CONNECTIONS AS OF SIGN. SIGNS SHOWN IN CORRIDORS ARE Electrical `N" .1_ Commercial Contractors Inc. Jake Money: jake@ccigc.com III. BUILDING STANDARDS: REQUIRED. CEILING HUNG. SIGNS SHOWN ON WALL ARE WALL 5573 S. 1st Circle 6. SURVEY EXISTING CONDITIONS OF ENTIRE FLOOR THAT EXIT ACCESS TRAVEL DISTANCE FROM MOST REMOTE POINT PER HUNG. Truss Engineering Ridgefield,WA 98642 BUILDING TYPE' TYPE IIB PROJECT OCCURS,AND PROVIDE NOT LESS THAN ONE TABLE 1016.2 Shop Drawings BUILDING OCCUPANCY: B APPROVED FIRE EXTINGUISHER WITH RATING OF NOT LESS E REQUIRED EXIT Telephone(503)227-4440 TOTAL BUILDING FLOOR RENTABLE AREA:+/- 16,453 R.S.F. OCCUPANCY SPRINKLERED REQUIRED PROPOSED Other THAN 2A 10B/C FOR EACH 1,500 S.F. OF FLOOR AREA OR FRACTION THEREOF. TRAVEL DISTANCE TO AN B Y 300'MAX 78'-8" IV. ADA ACCESSIBILITY UPGRADES: EXTINGUISHER FROM ANY PORTION OF THE BUILDING - 1. BUILDING HAS BEEN UPGRADED ACCORDING TO THE SHALL NOT EXCEED 75 FEET. PROVIDE FIRE EXTINGUISHER IN ACCORDANCE WITH CURRENT CODES. PROVIDE NEW COMMON PATH TRAVEL DISTANCE FROM MOST REMOTE POINT ACCESSIBILITY UPGRADES LIST AS OUTLINED IN OSSC 3411. FIRE EXTINGUISHER AT ALL EXISTING CABINETS WHERE DRAWING INDEX MISSING. ALL REUSED EXISTING FIRE EXTINGUISHERS ARE BEFORE 2 WAYS PROVIDED PER TABLE 1014.3 TO BE INSPECTED AND/OR RECHARGED, AS NECESSARY, OCCUPANCY SPRINKLERED REQUIRED PRE'g D PROJECT NUMBER: 218187 SHEET NAME JUST PRIOR TO SUBSTANTIAL COMPLETION. B Y 100'MAX 42'-6" A001 COVER SHEET A 100 GENERAL NOTES&STANDARD MOUNTING HEIGHTS Prim ePa y T.I. A201 DEMOLITION AND FLOOR PLANS A202 REFLECTED CEILING PLANS Atrium West A301 INTERIOR DETAILS 9600 SW Oak Street REVIEWED FOR Suite 380 DEFERRED SUBMITTALS - DESIGN BUILD GENERAL NOTES AREA OF WORK CODE COMPLIANCE Tigard, Oregon 97223 ELECTRICAL SYSTEMS LOW VOLTAGE SYSTEMS THE SITE PLAN AND SUITE LOCATION PLAN ARE FOR REFERENCE ONLY. SEE ALL OTHER PLAN SHEETS FOR CONTRACT DOCUMENT INFORMATION. THE PROJECT SUMMARY IDENTIFIES SOME SPECIFIC OSSC REQUIREMENTS BUT IS NOT INTENDED TO LIST ALL OSSC REQUIREMENTS. MECHANICAL SYSTEMS SPRINKLER SYSTEMS . . , PLUMBING SYSTEMS EGRESS LIGHTING OFFICE COPY / � F TIGARD 17"iiiiii r riii i ilii i __icy`/ CITY O '17 / / � r U L� ,; REVIEWED FOR CODE COMPLIANCE -11;:1 c'.F'.i'• n �� 1, A /IPA/4'4Y," ! 1oNnefnere�M. I . 41 UP--� • jj�� /_ r) / rp Piz:lt-6,rpeny s,r i.r � �Il��/.�►�./ _ �L`_�'� -P 4 - _ � Permit Its el./7)T?117—V i 7 , .» �"�yi.tlnFmkq ��� p '° � ` s:. �� - %�' �, r ►-40 5'��r� /� �i . Address: 9c 7 o sw 0c,1 - b .««. _. .wl ✓ q ```_ • _ 'o id At 'r .1�//.//r�� ^ Suite#: $ 0 5 �'° s • r..,� A. ~- — �- —,— s.v. -- — — — ..... d� / i �' 7,_�.'>>i'�'���, UN © B Date:- x' +Ts `�„ y 0° :*".....r. wr", J1 a -'z .max. « i -i''"-e.ems.. ...... wr.�. = `�V r 1/ , '�J II Flit= N • �i w;,sr:.*Vc, 59wre q k ^mrd Si. _A!j' rv:r -}, �u'"" n"nr -f..,' 11�� + 7 , / /i' q�y.,-.,�+�s..+..� _ ,. anm 1 awn i I f �` ft1 ETI c{e V7.0 - ' w „�,r: i I wr �"' � / �� � � �'il �. al V' HO: �/ ',I.,....� x .r...w a LJL ly i L 1--,- i _ I � , r / ,...„1 e ! I I I i ,� 1� I i I I I T jay +i j`�/ 11 11 .F anr._a. S Z :..x.‘11 �1'i l'-:Jt''' b �� �._ ~"1"---4. • -— 4f' '� f �� Sc _ . , , 1 i , e 1%,erd. ' Ao _ . 4 ,. __. , A I / 1 j r) SHEET TITLE: E „,,,,o'' y`J ... t �' k ”" \ I L i • I ',rf------- -- '( ! 1� i - / '% (41) I 41 t' J / 1 e_ SoAI,wK, r - IIID // r _ . CO ver Sheet .�s` dLYq 07t5t'aer ..��,.,, xv. \ i II= awo mt,---F-r --1a•'. „o.vuvi..o"rw• h, P + �' Amil ., I. p f11 AO JJ//�'`/, 1 - OF PER IVB DD F;rk... .... P -n �. 'CTS' !' i I .wm I I I I a " igi � E 7 1 , it �� ...E ,*wsr.n - r .« ' I � - / .t1. I _ 11 1 ` X94111. �� �1M + / ��1 ❑N onr THE ISSUANCE OFA PERMIT m�,'o..,., • �� t \ ..". I / I,:_ BASED ON CONSTRUCTION l g .. '' �s` ` �s K. ^-- J ,.." I ' i .{,. I i �� I (..�I 1 I r"` t��f r �'' �CCUPAN Y .� DOCUMENTS OTHER o M �„ C 3 FA= AND �R a' $ q = \ <` I / 1 i y �� _. AL - DATA SHALL NOT PREVENT _ - � '} � J THE CODE OFFICIAL FROM F r « - 'p yr w.a,na...c 9 ; i �_\r� ....w ..ir.u�f. _ - 'I -,1,. -, r I r /. ' ���, REQUIRING THE CORRECTION ill I.ff r o 9° aep� \114 1 t* O ' `, I s ...—I '%. `�',\ I ,G f 42.-s.lril iIMMINIIIIIMMONIMMO s Y �'�`� �: .......e + /r( /AL moi_ ice- —#/A _� I rl-' f 1 I l n C1 E DRAWN BY: M Te i ^�° w . �`, r Y kr' '' LL- // I Z/ZZI7 �I'It ' 1DATEISSUED: S7yp .. ..',•�E.•r,'e . +�� � ! I I- J ! a -_ ".'Y.: z a PERMIT SET 05.18.18 `Zp tN 1.e...Y ?'� A REVISED PERMIT SET 05.24.18 E N N N r- en 00 0 1. VICINITY MAP 2. SITE PLAN 3. SUITE LOCATION AND EGRESS PLAN n, CD KID A001 SCALE: NOT TO SCALE SCALE: NOT TO SCALE SCALE: 1/16"= V--0" 0 a a SHEET: N LAS Architects,inc.0 2018 E. tl 4-1. GENERAL NOTES 1 :116.1.1111.1.1151w S4 GENERAL DOOR AND HARDWARE 44. COORDINATE ELECTRICAL REQUIREMENTS FOR MECHANICAL SYSTEM. TO INDICATE THE DIRECTION OF EGRESS WHEN THE EXIT SERVES AN OCCUPANT LOAD OF ..�� 45. DESIGN-BUILD CONTRACTOR SHALL PREPARE A WRITTEN SCOPE OF HVAC WORK WITH BID. FIFTY OR MORE. 1. THE GENERAL NOTES ARE INTENDED THE DRAWINGS AND SPECIFICATIONS..OCONVEY DESIGN INTENT NOT THE PROJECT INTENT TO PROVIDE A COMPLETESE D IN 22. KNOWLEDGE OR EFFORTDOORS SHALL OPEN . CONTROLS THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL THIS IS TO INCLUDE NEW EQUIPMENT,NUMBER OF CONTRO S AND THERMOSTATS, ETC. OWNER WILL REVIEW SCOPE OFON AND QUANTITY WORK PROPOSED OF 68. FOOT-CANDLE AT THE FLOOR LEVELPROVIDE ILLUMINATION AT EXITS .PROVIDE EMERGENCY SYSTEM LIGHTING WHERE THE H LIGHT HAVING THE INTENSITY OF NOT LESS THAN 1 ARCHITECTS WORKING TENANT OR BUILDING IMPROVEMENT. 23. NEW DOOR HARDWARE SHALL MATCH EXISTING BUILDING STANDARD LEVER HANDLE WITH PRIOR TO ACCEPTANCE OF BID. EXISTING SYSTEM SERVES AN OCCUPANT LOAD OF A 100 OR MORE AS REQUIRED BY CODE. 720 NW Davis 503.221.1121 IR 2. ALL WORK SHALL CONFORM TO THE 2012 INTERNATIONAL BUILDING CODE(IBC), 2014 FINISH TO MATCH BUILDING STANDARD. FINISH OF HINGES AND CLOSERS TO MATCH. ALL 46. DESIGN-BUILD CONTRACTOR TO PROVIDE CERTIFICATION THAT OUTDOOR AIR MATCH EXISTING BUILDING STANDARD WHERE POSSIBLE FOR REQUIRED EMERGENCY OREGON STRUCTURAL SPECIALTY CODE(OSSC), 2014 OREGON MECHANICAL SPECIALTY HARDWARE SHALL BE ADA ACCESSIBLE. REQUIREMENTS OF CURRENT CODES WILL BE MET FOR EACH OCCUPANCY USE WITHIN THE SYSTEMS AND INSTALL IN ACCORDANCE WITH THE REQUIREMENTS OF THE CURRENT Suite 300 503 221.2077 D CODE(OMSC), 2014 OREGON FIRE CODE,2014 OREGON ENERGY EFFICIENCY SPECIALTY 24. CONTRACTOR SHALL VERIFY COMPATIBILITY OF HARDWARE SPECIFIED WITH BUILDING TENANT IMPROVEMENT AREA. NATIONAL ELECTRICAL CODE Portland OR 97209 www.Irsarchitects.cQm CODE(OEESC),2014 OREGON PLUMBING SPECIALTY CODE(OPSC), 2014 OREGON ELECTRICAL KEYING SYSTEM. 47. INTERIOR AND PERIMETER OFFICES SHALL NEVER BE ON THE SAME ZONE. CONFERENCE 69. PROVIDE VISUAL AND AUDIBLE ALARM SIGNAL APPLIANCES INTEGRATED INTO THE BUILDING SPECIALTY CODE(OESC)AND TO CONDITIONS AND SPECIFICATIONS OF ALL GOVERNING 25. PROVIDE NEW DOORS MATCHING EXISTING DOORS'VENEER SLICING PATTERN AND GRAIN ROOMS AND LUNCHROOMS CAPABLE OF SEATING(6) OR MORE SHALL ALWAYS BE ON THEIR ALARM SYSTEM AS REQUIRED BY ADA AND CURRENT OSSSC STANDARDS. PROVIDE AUTHORITIES. DENSITY,AND FINISH. OWN ZONE. ADDITIONAL ELECTRICAL SERVICE AS REQUIRED. COORDINATE REQUIREMENTS WITH 3. CAREFULLY EXAMINE THE PROJECT SITE AND CONSTRUCTION DOCUMENTS. VERIFY ALL 26. PROVIDE CLOSERS ON ALL TENANT ENTRY OR EXIT DOORS TO MATCH EXISTING BUILDING 48. DESIGN-BUILD CONTRACTOR SHALL VERIFY THE SUITABILITY AND CONDITION OF SCHEDULED BUILDING OWNER. ALARM LOCATIONS INDICATED ON PLANS ARE ONLY FOR REFERENCE. DIMENSIONS AND CONDITIONS PRIOR TO START OF WORK AND REPORT ANY DISCREPANCIES STANDARD FINISH AND TYPE. EQUIPMENT TO BE RE-USED OR RELOCATED. DETERMINE ITEMS THAT NEED TO BE 70. PROVIDE SHOP DRAWINGS FOR ALARM SYSTEM LAYOUT AS REQUIRED BY CODE TO THE ARCHITECT. 27. PROVIDE DOOR OPENINGS IN RATED WALLS COMPLYING WITH REQUIRED SMOKE CONTROL REPAIRED OR REPLACED. PRICE THESE ITEMS SEPARATELY AND AS EXCEPTIONS/ 71. VERIFY SERVICEABILITY AND REUSABILITY OF EXISTING ELECTRICAL EQUIPMENT,AND e t%101) 1440,4& 4. OBTAIN AND PAY FOR ALL PERMITS AND FEES TO COMPLETE THE WORK. OBTAIN AND PAY ASSEMBLY AND INDICATED FIRE PROTECTION RATING OF NO LESS THAN 20 MINUTES. CLARIFICATIONS IN BID. REPAIR OR REPLACE AS NECESSARY. FOR ADDITIONAL DRAWINGS AND SPECIFICATIONS REQUIRED FOR PERMITS. WHERE EXISTING DOOR OPENINGS DO NOT COMPLY WITH PRESENT BUILDING CODE 49. AUTOMATIC SPRINKLER SYSTEM SUPERVISION: ALL VALVES, INCLUDING THOSE IN PITS, 72. VERIFY THE CAPACITY AND REUSABILITY OF EXISTING ELECTRICAL PANELS TO MEET 5. THE CONTRACTOR SHALL PROVIDE AND PAY FOR DUMPSTER AND TELEPHONE. REQUIREMENTS, PROVIDE NEW DOORS,FRAMES AND HARDWARE THAT COMPLY. SHALL BE MONITORED BY UL LISTED FIRE MARSHAL-APPROVED CENTRAL STATION. WATER PROJECT REQUIREMENTS. , T 6. COORDINATE ARCHITECTURAL WORK WITH MECHANICAL AND ELECTRICAL DESIGN BUILD 28. ADJUST THE RESISTIVE FORCE OF ALL NEW AND EXISTING INTERIOR DOOR CLOSERS IN THE FLOW AND HIGH/LOW PRESSURE FOR DRY PIPE SYSTEMS IF USED)SHALL BE SUPERVISED, 73. TERMINATE ALL CONDUITS IN STANDARD DUPLEX BOXES, UNLESS OTHERWISE INDICATED. WORK AND SUBMIT ALL DESIGN BUILD PLANS TO ARCHITECT FOR REVIEW PRIOR TO PROJECT AREA TO A MAXIMUM PRESSURE OF 5 LBS. TO COMPLY WITH ADA REQUIREMENTS. AS WELL AS OTHER FEATURES DEEMED NECESSARY BY CURRENT NATIONAL FIRE 74. KNOWN EXISTING(E)ELECTRICAL AND PHONE/DATA OUTLETS HAVE BEEN INDICATED ON THE CONSTRUCTION. PROTECTION ASSOCIATION STANDARDS. DRAWING. ADDITIONAL EXISTING OUTLETS MAY EXIST AND SHOULD BE VERIFIED BY f41 # ; 7. DIMENSIONS TAKE PRECEDENCE OVER SCALE. DIMENSIONS ARE TYPICALLY TO FACE OF FINISHES 50. PREPARE SPRINKLER SYSTEM SHOP DRAWINGS FOR COORDINATION WITH ARCHITECTS CONTRACTOR. PORILAMI, '`4:.•` FINISH UNLESS OTHERWISE NOTED. DRAWINGS BY ARCHITECT. 75. VERIFY WITH TENANT OR OWNER LOCATIONS OF ELECTRICAL AND VOICE/DATA OUTLETS FOR t G3�► 8. KEEP PROJECT AREA OF WORK FREE OF GARBAGE AND DEBRIS ON A DAILY BASIS. 29. REPAIR/REFINISH ANY DAMAGE TO EXISTING FINISH SURFACES IN IMPROVEMENT AREA 51. PAY ALL FEES AND OBTAIN ALL PERMITS AND APPROVALS FROM GOVERNING AGENCIES SYSTEMS FURNITURE PRIOR TO INSTALLATION. 741 9. DO NOT DISTURB ADJACENT TENANTS BY NOISY CONSTRUCTION(i.e.,JACK HAMMERING OR CAUSED BY CONSTRUCTION OPERATIONS. NECESSARY TO COMPLETE THE WORK. 76. SMOKE DETECTION DEVICES INDICATED ON THE DRAWINGS ARE FOR REFERENCE ONLY. OFoie CORE DRILLING), OR ODORS(i.e., PAINTING OR ADHESIVE FROM FLOOR OR WALL 30. PAINT EXISTING WALLS WITH 2 COATS OF EGGSHELL FINISH PAINT UNLESS OTHERWISE 52. PROVIDE FIRE DAMPERS AS REQUIRED BY CURRENT OSSSC STANDARDS FOR NEW CONFIRM SPACING OF DETECTORS WITH DEVICE LISTING. COVERINGS), SCHEDULE SUCH ACTIVITIES FOR AFTER NORMAL BUSINESS HOURS. NOTED. SUBMIT COLOR DRAW-DOWNS TO ARCHITECT AND OWNER FOR APPROVAL PRIOR TO CONFIGURATION OF FIRE-RATED PARTITIONS. 77. CLEAN AND REPAIR EXISTING SMOKE DETECTORS TO BE REUSED TO GOOD WORKING COORDINATE SUCH ACTIVITIES WITH BUILDING OWNER. APPLICATION. 53. BALANCE DESIGN-BUILD HVAC SYSTEM TO TENANT AND BUILDING OWNERS SATISFACTION. CONDITION. 10. STORAGE OUTSIDE OF BUILDING IS NOT ALLOWED WITHOUT AUTHORIZATION BY BUILDING 31. WHERE ALL NEW PARTITIONS ABUT,JOIN OR CONNECT TO EXISTING SURFACES, WALLS, OR TOUR EXISTING CONDITIONS AND CONTACT OWNER FOR QUESTIONS PRIOR TO BID. 78. CLEAN NEW,EXISTING,AND RELOCATED LIGHT FIXTURES IN PROJECT AREA, OR IN AREAS OWNER. NEW CONSTRUCTION, THE FINISHED SURFACE SHALL BE ALIGNED FLUSH. 54. INSTALL TEMPORARY FILTERS ON HVAC VAV BOXES AFFECTED BY WORK OF PROJECT PRIOR AFFECTED BY WORK OF THIS PROJECT,AT COMPLETION OF JOB. RELAMP AND REPLACE 11. OWNER SHALL NOT BE RESPONSIBLE FOR TOOLS OR MATERIAL GOODS STOLEN OR 32. ALL NEW WALLS AND PARTITIONS SHALL HAVE TAPED JOINTS(3) COATS SANDED AND PRIMED TO CONSTRUCTION. REMOVE FILTERS AT COMPLETION OF THE PROJECT. BALLAST IN LIGHT FIXTURES AS REQUIRED TO RESTORE TO WORKING ORDER. CONSULTANT: DAMAGED ON SITE. TO MEET PAINT READY REQUIREMENTS. 55. COORDINATE ZONE CONTROL OF EXISTING HVAC SYSTEM AT IMPROVEMENT AREA. 79. CLEAN AND REPAIR EXISTING EXIT SIGNS TO BE REUSED. REPLACE BATTERY AND/OR 12. CONTACT OWNER'S REPRESENTATIVE TO COORDINATE SCHEDULED ITEMS TO BE SALVAGED 33. EXISTING WALLS AND SURFACES SHALL BE STRIPPED, RESURFACED,AND PATCHED AS SEPARATE AND REROUTE EXISTING DUCTWORK AND CONTROLS REQUIRED TO PROVIDE BALLAST IF NOT IN GOOD WORKING CONDITION. FOR RETURN. REQUIRED. INDEPENDENT OPERATION BY TENANTS ON EACH SIDE OFA DEMISING WALL. 80. COORDINATE TELECOMMUNICATIONS AND MODIFICATION TO BUILDING ALARM SYSTEM 13. UPON COMPLETION OF WORK, BE RESPONSIBLE FOR RETURN TO OWNER OF ALL MASTER 34. DISPOSE OF ALL PAINT MATERIALS OFF SITE. DO NOT POUR DOWN DRAINS, CATCH BASINS, 56. CLEAN ALL NEW AND EXISTING HVAC GRILLS AND DIFFUSERS SCHEDULED TO REMAIN. ALL PROVIDED BY TENANT. VERIFY WITH TENANT LOCATION OF NEW OUTLETS PRIOR TO KEY ORIGINALS OR CARD ACCESS DEVICES. OR IN LANDSCAPING. DUCTWORK BEHIND GRILLS SHALL BEA UNIFORM DARK COLOR. INSTALLATION. 14. WARRANTY ALL PARTS,LABOR,EQUIPMENT,AND MATERIAL PROVIDED UNDER THIS 35. PROVIDE A FULL GALLON OF EACH WALL COLOR WITH LABELS IN TENANT CLOSET OR UNDER 57. DESIGN-BUILD CONTRACTOR AT COMPLETION SHALL PREPARE AND SUBMIT AN AIR 81. REMOVE ALL UNUSED OR ABANDONED ELECTRICAL WIRING,EQUIPMENT,AND PHONE AND CONTRACT OFA PERIOD OF ONE YEAR, UPON FINAL COMPLETION OF CONTRACT. SINK, LABEL ALL LEFT OVER PAINT,AND DELIVER TO OWNER WHERE DIRECTED. BALANCING REPORT TO THE OWNER. DATA CABLING. CONFIRM WITH OWNER PRIOR TO REMOVAL.ALL WIRING AND CABLING TO 15. SUBMIT SUBSTITUTION REQUESTS ON CS/FORM TO ARCHITECT FOR APPROVAL. 36. TAPE AND SAND EXPOSED GYPSUM BOARD FOR A FLAT, SMOOTH SURFACE FINISH TO MATCH 58. HVAC CONTRACTOR TO PROVIDE 100%FRESH AIR SUPPLIED TO ENTIRE TENANT SPACE REMAIN SHALL BE SUSPENDED FROM STRUCTURE AS REQUIRED BY CURRENT CODE. ARCHITECTS DECISION IS FINAL WHETHER A PROPOSED PRODUCT IS ACCEPTABLE FOR EXISTING ADJACENT SURFACES IN BUILDING, UNLESS OTHERWISE INDICATED. THREE CALENDAR DAYS PRIOR TO THE FIRST DAY AFTER SUBSTANTIAL COMPLETION. SUBSTITUTION. 37. PROVIDE FINISH MATERIALS MATCHING ESTABLISHED BUILDING STANDARD QUALITY, UNLESS PROVIDE 100%FRESH AIR WITHOUT MAKING OTHER TENANTS UNCOMFORTABLE SCHEDULING OF FIRE SPRINKLER AND ALARM SYSTEMS 16. APPLICATION OF MATERIALS TO SURFACES EXISTING OR PROVIDED UNDER THIS CONTRACT OTHERWISE INDICATED. PROVIDE COLORS APPROVED BY OWNER AND ARCHITECT. IMPLIES ACCEPTANCE AND SUITABILITY OF EXISTING CONDITIONS. 38. CONTRACTOR TO FILL AND PATCH EXISTING CONCRETE SLABS AND SHALL PROVIDE SMOOTH ELECTRICAL-DESIGN BUILD 82. CONTACT OWNER'S REPRESENTATIVE FOR INSTRUCTIONS WHEN SCHEDULING WORK ON 17. ALL WORK INDICATED ON DRAWINGS SHOULD BE CONSIDERED NEW UNLESS IDENTIFIED AS UNIFORM SURFACE PRIOR TO NEW FLOOR COVERINGS TO BE INSTALLED. FIRE SPRINKLER&ALARM SYSTEMS. EXISTING TO REMAIN OR TO BE REUSED. 59. ELECTRICAL SYSTEM AND REQUIREMENTS ARE DESIGN-BUILD. SUBMIT ELECTRICAL DESIGN 18. ALL MATERIALS AND PRODUCTS USED ON THE JOB SITE SHALL BE"ENVIRONMENTALLY SAFE", FURNISHINGS TO ARCHITECT FOR COORDINATION WITH ARCHITECTS DRAWINGS PRIOR TO ACCESSIBLE FIXTURE MOUNTING REQUIREMENTS LOW ODOR,AND NONFLAMMABLE. USE OF ANY PRODUCT NOT COMPLYING WITH THIS CONSTRUCTION. CRITERIA MUST BE APPROVED BY THE BUILDING OWNER. 39. INSTALL BUILDING STANDARD WINDOWCOVERINGS AT ALL PERIMETER WINDOWS IN 60. IF AN OVERRIDE SYSTEM EXISTS, PROVIDE EACH TENANT SPACE WITH AN OVERRIDE SWITCH 83. ALL DIMENSIONS INDICATED ON THIS SHEET ARE CLEAR MINIMUM TO FACE OF FINISH. 19. CONTRACTOR WILL BE HELD RESPONSIBLE FOR ANY DAMAGE OR CLEANING THROUGHOUT IMPROVEMENT AREA UNLESS OTHERWISE NOTED. DO NOT PROVIDE NEW IF ALREADY FOR FULL-SERVICE BUILDINGS. DIMENSIONS TO TOILET ROOM ACCESSORIES ARE TO THE CENTER LINE AS NOTED OR TO THE STRUCTURE DEEMED TO BE A RESULT OF HIS/HER WORK. THOROUGHLY CLEAN PREMISES EXISTING. REPAIR AND/OR REPLACE ANY DAMAGED WINDOWCOVERINGS TO MATCH 61. PAY ALL FEES AND OBTAIN ALL PERMITS AND APPROVALS FROM GOVERNING AGENCIES HIGHEST PORTION OF THE OPENING OR OPERATING DEVICE. UPON COMPLETION OF WORK, INCLUDING WASHING OF WINDOWS, SO THAT BUILDING IS EXISTING. NECESSARY TO COMPLETE WORK READY FOR OCCUPANCY BY TENANT. INCLUDE CLEANING OF ADJACENT AREAS WITHIN AND 40. FURNITURE INDICATED ON PLANS IS FOR REFERENCE ONLY AND SHALL BE CONSIDERED NOT 62. COORDINATE ITEMS REQUIRED FOR DEMOLITION NOT INDICATED ON DRAWINGS. 84. ALL ITEMS INDICATED BELOW MAY NOT OCCUR ON THIS PROJECT. SEE PROJECT PLANS AND AROUND THE BUILDING THAT ARE NOT PART OF TENANT IMPROVEMENTS, BUT WERE IN CONTRACT. 63. COORDINATE ELECTRICAL REQUIREMENTS FOR MECHANICAL SYSTEMS. ELEVATIONS FOR ITEMS THAT OCCUR. SEE ARCHITECTURAL PLANS FOR ACCESSIBILITY AFFECTED BY TENANT IMPROVEMENT CONSTRUCTION OPERATIONS. 64. DESIGN-BUILD CONTRACTOR SHALL PREPARE A WRITTEN SCOPE OF ELECTRICAL WORK TO AND/OR ADAPTABILITY CONFORMANCE IN THE HORIZONTAL PLAN LAYOUT. 20. CONTRACTOR TO PROVIDE MECHANICAL AND ELECTRICAL AS-BUILT DRAWINGS,ALL BE PERFORMED TO THE OWNER WITH BID. WARRANTIES AND OPERATING MANUALS TO BUILDING OWNER WITHIN TWO WEEKS OF MECHANICAL-DESIGN BUILD 65. ELECTRICAL LIGHTING ON DRAWINGS IS PROVIDED FOR REFERENCE ONLY AND IS INTENDED 85. CONFORMANCE TO FIXTURE MOUNTING HEIGHT REQUIREMENTS ARE APPLICABLE IN ANY COMPLETION OF WORK. CONTRACTOR ALSO IS TO PROVIDE FINAL CERTIFICATE OF TO SHOW FIXTURE TYPES AND LOCATIONS. ELECTRICAL DESIGN IS BY DESIGN-BUILD PUBLIC AREA OR EMPLOYEE AREA MORE THAN 1000 SF,AS THEY OCCUR PER PROJECT. OCCUPANCY. NO RETAINAGE SHALL BE RELEASED UNTIL OWNER HAS RECEIVED THESE 41. MECHANICAL SYSTEM AND REQUIREMENTS ARE DESIGN-BUILD. SUBMIT PLANS AND CONTRACTOR IN ACCORDANCE WITH EXISTING BUILDING STANDARDS. COMPLY WITH ITEMS. SPECIFICATIONS TO ARCHITECT FOR COORDINATION WITH ARCHITECTS DRAWINGS, IN ENERGY CODE REQUIREMENTS AS REQUIRED BY CURRENT ENERGY CODES AND PROVIDE 86. VERIFY ACCESSORY SIZE WITH MANUFACTURER TO ENSURE CONFORMANCE WITH REQUIRED 21. ALL DEMOLITION WORK TO CONFORM TO CURRENT OSHA STANDARDS. PROVIDE ADEQUATE ADDITION, CONTRACTOR SHALL PROVIDE WITH SUBMITTAL (2)COPIES OFA COLORED FLOOR ENERGY CALCULATIONS REQUIRED FOR WORK OF THIS PROJECT. MOUNTING HEIGHTS. BRACING ON EXISTING CEILING FRAMING SYSTEM PRIOR TO DEMOLITION. PLAN DESIGNATING WHICH AREAS ARE CONTROLLED BY EACH THERMOSTAT. MECHANICAL 66. SWITCHING FOR LIGHTING IS INDICATED IN THE DRAWING FOR REFERENCE ONLY AND IS DESIGN MUST BE APPROVED BY OWNER AND MECHANICAL ENGINEER IF EMPLOYED BY INTENDED TO ONLY SHOW SWITCH LOCATIONS. REQUIREMENTS FOR DUAL SWITCHING, 87. PROVIDE CODE-COMPLIANT BLOCKING WITHIN WALLS AS REQUIRED FOR PROPOSED AND ARCHITECT PRIOR TO CONSTRUCTION. AUTOMATIC AREA SHUT OFF CONTROLS AND ALL OTHER CODE REQUIREMENTS SHALL BE THE FUTURE ACCESSORIES AND GRAB BAR MOUNTING FIXTURES. BLOCKING IS REQUIRED FROM 42. PAY ALL FEES AND OBTAIN ALL PERMITS AND APPROVALS FROM GOVERNING AGENCIES RESPONSIBILITY OF THE DESIGN-BUILD CONTRACTOR. PROVIDE A MINIMUM OF ONE SWITCH STUD SPACE TO BACK OF SURFACE OF ALL FIXTURES INCLUDING BUT NOT LIMITED TO NECESSARY TO COMPLETE WORK. PER ROOM, UNLESS OTHERWISE INDICATED. TUB/SHOWER ENCLOSURES. 43. COORDINATE ITEMS REQUIRED FOR DEMOLITION NOT INDICATED ON DRAWINGS. 67. PROVIDE ILLUMINATED EXIT SIGNS AT REQUIRED EXIT DOORWAYS AND WHERE NECESSARY 88. FLOOR DRAINS: ACCESSIBLE FIXTURES REQUIRE A CLEAR FLOOR SPACE CONTIGUOUS OR OVERLAPPING THE ACCESSIBLE ROUTE. FLOOR DRAINS SHOULD NOT BE PLACED IN THIS CLEAR FLOOR SPACE EXCEPTION: DRAINS MAY RESIDE IN CLEAR FLOOR SPACE PROVIDED PROJECT NUMBER: 218187 DRAIN HOLES DO NOT EXCEED 1/2"DIA. MAX.;FLOOR SLOPE DOES NOT EXCEED 2%IN ANY DIRECTION;AND THE ELEVATION CHANGE AT THE DRAIN LIP DOES NOT EXCEED 1/8". TOWEL DISPENSER AND END OF GENERAL NOTES Prim ePa y El. WASTE RECEPTACLE HAND DRYER EXIT SIGN '4.4 COAT&UTILITY SOAP i TYPICAL DOOR HOOK DISPENSER 39"-41" GRAB BAR, 18'MIN Atrium West 36"MAX GRAB BAR,42"MIN 9600 SW Oak Street OPENING ,/9 TO RAISED 12"MAX 4"MIN1.4/ ACCESSORY ZONE Suite 380 S. CHARACTERS ♦ --, „2 ♦ `}' IF j �` �' ---Iv D ° ♦ I "N Tigard, Oregon 97223 -4) i____ T : A to - CARD too i) v v to O co U `ao 0 READER `r 2 `r F- `r p .sr t- ��` # M I•- M W • ♦ '`� ♦ 4, 42"MAX / Ir,1,41 ;r :.i==- - _ *�, - , TYPICAL AT DOOR TOILET-SURFACE MOUNT I t .c�" 0) 1s _\ 2 z Al�� TOILET ROOM MOUNTINGS ACCESSORY ZONE(SECTION 504.7) R Fit t .� /�/f I► co ♦ '. �4 11f \ Illi, VISIBLE SYMBOLS,EACH FIRE ALARM SIGNAUSTROBE ANNUNCIATOR PANEL 10"MAX MIN.21/2"HIGH OPERABLE THERMOSTAT WALL MOUNTED FIRE EMERGENCY POWER ♦ EXISTING ELEVATOR 54"MAX FIRE EXTINGUISHER SIGN 2'-6" Fig.308.2.1 Fig.308.3.1 qCALL BUTTON ELEVATOR TO COMPLY WITH MOUNTED PHONE EXTINGUISHER MANUAL PULL RECESSED FIRE OFF PUSH BUTTON 39"-41" GRAB BAR,18"MIN AHJ.AND ADA EXTINGUISHER CABINET CLEAR FLOOR SPACE CLEAR FLOOR SPACE UNOBSTRUCTED UNOBSTRUCTED -I 7 ELECTRICAL OUTLET STATION7 ♦ TACTILE PARALLEL APPROACH FORWARD APPROACH FORWARD REACH SIDE REACH 36"MAX GRAB BAR,42"MIN INTERCOM SIGNAGE ♦ �' ELECTRICAL OUTLET TELEPHONE STATION N-�-' " 4"MIN AT CASEWORK OUTLET AND "� BASE OF / �j/i'�/%'/ 4 MAX ACCESSORY ZONE \\Ii SWITCHES-7 7.- -^ic(.3-i { u. CHARACTER cl- Ct �F,�,�},lj� ? t�ti�,l� 1r b t3I t w ¢ z o w _ w > > o z z 2Q RR.. (►� �i lam ��i 1� �// (V w w " Ya t ; t,i,'`''w�.a�j 1�I�i:�:�`� nun a z h. -.! C1 EL t c t ~ . C� LL i[') t 1 -47,Lit ~'1o, �1 ft z ♦. `.7 p v M O •i Q Z w v o 0 cvt co t m in r w w _ q cot SHEET TITLE: a 20"MAX >20"-25" g ri, r; o, o s,,a 1. Q w o p a. a. 0 �, �, ~ General Notes & Fig.308.2.2 co �, y ♦ .�., ♦ ♦ ♦ - ♦ ♦ ♦ v ♦ ♦ • ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ OBSTRUCTED HIGH FORWARD REACH / 42"MAX I , " m "' TOILET-RECESSED MOUNT TYPICAL AT ELEVATOR MISCELLANEOUS WALL MOUNTINGS 5-0Standard {r/C�uII�I g `° 10"MAX ;lo240 " Hei his ♦ _;, . ACCESSORYZONE(SECTION 604..) " 12 MIN 32"CLEARAT 11 24 MIN •C • a' �. LIMITS OF PROTRUDING OBJECTS 31/2" ( 12"MAX 3'4" #- 36"GRAB BAR uS FOR PARALLEL - REFLECTIVE SHELF AND " I �=--- - �► 2 reEXCEPTIONS: 18 VERTICAL c� ♦ " " o` 0g eo m 1. HANDRAILS MAY PROTRUDE 41/2"MAX, APPROACH y " 17 TO 25 SURFACE POLE GRAB BAR 12 MIN j o-'tF g t am'' 15"MIN FOR 5"MAX // 42 GRA BAR " 1 �I �' 1h 1 `' +�' `id DOOR CLOSERS AND DDDR STOPS ^ t B I I yr z .. w A .� ♦ FORWARD FOR FORWARD - LAVATORY&LAV c z SHALL BE PERMITTED TO BE 78"MIN APPROACH APPROACH LU z �� -- IN COUNTER " " OBY: LRS Fig.308.3.2 co m -�'k u /I ♦(*I i �-", A- 8 MIN Ly DRAWN ABOVE FLOOR m - - ' m z > _"� ; 3 m♦ (+1 2 C 3+ ', (V SCREEN •- . INSULATE EXPOSED ♦ 1r SPOUT OUTLET w LAV �- O 111 RIM z p DATE ISSUED: E OBSTRUCTED HIGH SIDE REACH IGC/ANSI A117.1-2009 SECTION 308 REACH g RANGES(ALL DIMENSIONS ARE NOT TO SCALE) $"MIN ¢ cc > g o,IT, d'/ Q O r ��� ♦ •♦ ( T SUPPLYANDz if-Y i ,� PERMIT SET 05.18.18 •ix ED , ¢ m © v. °z tn c� ar+ `� N 18"VERTICAL DRAIN °' i ♦ I-I �� ♦ A GRAB BAR URINAL PIPES TYP �� N REVISED PERMIT SET 05.22.18 a 6"M 11"MIN ° M SIDE APPROACH rn �16-18"1, 42"GRAB BAR 6"MAX II 11"N IN •�� co m DRINKING FOUNTAIN(SECTION 802) MIRRORS(SECTION 603.3) SHELVES(SECTION 603.4) WATER CLOSET(SECTION 604) FLUSH CONTROLS ON WATER CLOSET-PLAN OPEN SIDE OF WATER CLOSET (SECTION 604) URINALS(SECTION 805) LAVATORYAND SINKS(SECTION 606) i 1. ACCESSIBLE FIXTURE MOUNTING REQUIREMENTS (PER ICC/ANSI Al17.1-2009) g SCALE: NOT TO SCALE A100 a SHEET: s ccv LRS Architects,Inc.®2018 g. e N A I 4 LL 1 a 4 3 I ARCHITECTS ci0720 NW Davis 503.221.1121 e „ „ " 11u v Suite 300 503 221.2077 0 e u 00 11 U 11 u 0 O 0 0 0 ' 646!. 6 6 ® a Portland OR 97209 www.Irsarchitects.com .P4'. t4at II Q — Q O— 1:34r) O Q a O— Jf ® 1.U.. ` , t ! • 1 t ,olii O TVG T J l V �j ,.� p,:I aJ � O - i3 �_� =� �_� �_� i `.,�,1� p � 0 " Iii` ® i ( I I I I I I I IN N ^ NQ r q (� i f of r r r r=� N CONFERENCE G' �, ,►, Q �'' r- I ' r- I r- I ' r , Zit Ii1 j I I , I 11 , I 1, , 1 I, 1 OFFICE OFFICE ROOM Q STORAGE `$'it o1 Q os 1 oh- All l L.—di i L �1 1 t �i 1 �-,', 306 305 304 os 1 303 0 _ I 11-----J L---_J L-----I L_--_J � ,,¢S � �p S 40r) 411_' tt-' CO , ITYPx640' t t t t {I}N V}N s• r'—`t LL t tt • © Exli ----, t/�v/c ?'f (�az• I - - 1__ 1_= 1=_ r+69� // (} I/ �� i I I i I I I 1)3 �U t�(H L_ / �,#�,r/� �{ yL - -----IL = �-- CJ U r r r�+ ��1 I I i 1 1 1 I Z (f) - "t I�CL_1 �.jtF- ( _ 'rrC 0 IIr..-- , r----7 r----1 r----1t�1� �1._..._t I 0 . :s"■ 1 I 1 i 1 i F J �=� u� {E)CPT,`(�IVC i`t.1'1 �i I I 11 i r it I I��i ALIGN 5'-6" {I?)CP��lvr-1 N +A2. D3 i�j. L�f f �1 s _,i f L_ I I BREAKrae I/ i D2 (J) D1 '�i3 E=H 6=4 6_= �6_ ECL T R �/ R00302M 3 PDRF ►' :,.a: ' -. TYP 0. 1l ,I ` = 11�T L�S� >• OPEN 10 N. F=� F=9, F=9, F=1 F=1 t $ ` s.u. 442• r42• I� OFFICE O U I I 1 I I I 1 f I I 307 TYP it I i � i r=�1 I ��i t �1 - n 7i�WTII1I e�i�i�I 42" 1412' •• -- ---- -' H i II I i Ii I I, t i, , Li: ,,5.___o__, _ �% OF AL I P=� P= i== , i== I 1 I �t I > 64, , _jI I =hi s AL -- --- - - R" T 1` r'I �t A �—i f �1 I �='tt L____J L____J L____J L__-_J L____J CPT-1 t I I I I I 1 I i I 1 I I I t 1 I I (ENC oS 6 6 PVC Sas() �0 0 _ iIl t II L 1 I I I 1 t� 0 0 •I �-=_I II L--_-�I I L--_-�I 11 1 I I I I I I I I I NO- - 42` I�L____J IL____J L_____J L____J ____ __ ____ __#____ ,=_#==== == === == 1 U 1 i 1 I I I I I i t ! f i I i .. O 42' l g9N 1 II I t 1 I 1 I I I I i I i I I I - 11 1 -- - -- - -- -- r- __ r----� r---- r---- 1 r---- Na+Ei✓< I I I I I I i 1 I SERVE' f "�' i t i t i i t �I I II II 1 I 1 1 1 it�I ROO CONSULTANT: �� • I I _ I I L_ I I I I _ I I _ ENTRY ` ji ' r--- , r---- , r---- , r---- , �_ �� �� �� 300 — /\��4^�/� 301 'I T- �I 1 r-�I I �-�1 I rel u 6=� =d 6=d 6=� 6=d^ i3 `-� I r 1 I r I I r I I = I '�� )'I iL�1 I i4 1 It�I 1 1L-_,-/I 41) 41) I ` t I• ( I� 6_ 6_ f*=� 6=� 1 OFFICE -R R R Cr \ � i A I � � ;' Is, +3 ® {424 AI 1 311 �0ri ♦ a ® Qz• 1 0 411 ,i • a fy -:)_,, % „ OS - OFFICE os- 308 0 0 �, 0 N 0 ® �„ �A� (E)CPT, 0 FINISH LEGEND 0 t II , ,, �;• EW NE em A * ALL FINISHES TO BE BUILDING STANDARD UNLESS OTHERWISE NOTED id os 1N - N os- CARPET TILE P CPT-1 MATCH EXISTING 0 �tn. 0 0 LUXURY VINYL TILE • air. J Tr , r LVT-1 TO BE SELECTED �' D2 �,\ G i� WORK N OPEN G - RUBBER BASE 0 • ROOM j OFFICE 0 _ RB-1 MATCH EXISTING 0 �S h1 0 309 310 IH 1 Nd® 1=! 1 PAINT 1 , P-1 (GENERAL)TO BE SELECTED .0 It- 0 4 P-2 (ACCENT)TO BE SELECTED - EP - EP P-3 (ACCENT)TO BE SELECTED 1 t 0 ,.. 0 le Q0 P 0 .- 1 LV I :QV PROJECT NUMBER: 218187 N N PrimePay Ti. 1. DEMOLITION PLANCD 2. FLOOR PLAN (I)SCALE: 1/8"= 1'-0" Atrium West LEGEND FLOOR PLAN GENERAL NOTES LEGEND 9fi00 SW Oak Street SCALE: 1/8"= V-O" DEMO PLAN GENERAL NOTES Suite 380 A. REFER TO SHEET A100 FOR A COMPLETE LIST OF GENERAL NOTES. A. REFER TO SHEET A100 FOR A COMPLETE LIST OF GENERAL NOTES. Tigard, Oregon 97223 i EXISTING PARTITION EXISTING PARTITION B. EXISTING FLOORING&BASE TO REMAIN UNLESS OTHERWISE NOTED. B. DIMENSIONS ARE TO FACE OF WALL UNLESS OTHERWISE NOTED. ADVISE ARCHITECT OF ANY DISCREPANCIES PRIOR TO c 3 DEMO EXISTING WALL AND/OR ELEMENT CONSTRUCTION. w' ''•''1 4 NEW FULL HEIGHT PARTITION TO STRUCTURE C. PROTECT ALL ADJACENT AREAS DURING DEMOLITION&FROM DUST AND TRASH INTRUSION. (SEE DETAIL 21 A301) C. ALL ELECTRICAL WORK IS DESIGN BUILD-ALL ELECTRICAL OUTLETS,DATA&SWITCHES SHOWN FOR REFERENCE ONLY. D. REMOVE&SALVAGE DOORS,FRAMES,HARDWARE&R£LITES FOR REUSE. VERIFY EXISTING CONDITIONS. EACH ENCLOSED ROOM TO HAVE A MIN.OF(1)LIGHT SWITCH,(2)DUPLEX OUTLETS,AND RING monnommoma NEW BUILDING STANDARD PARTITION &STRING FOR(1)TENANT-PROVIDED LOW VOLTAGE DROP-PROVIDE AS NEEDED. SUBMIT ELECTRICAL PLANS TO ARCHITECT (SEE DETAIL 11 A301) E. REMOVE BLINDS&WINDOW COVERINGS FOR REUSE.CLEAN AND REINSTALL PRIOR TO JOB FOR REVIEW PRIOR TO CONSTRUCTION. COMPLETION.REPAIR AND/OR REPLACE ANY MISSING AND/OR DAMAGED 1 ° NEW 6'HIGH PARTIAL HEIGHT WALL WINDOWCOVERINGS TO MATCH EXISTING AS NEEDED THROUGHOUT ENTIRE AREA OF WORK. D. WHEN NEW LIGHT SWITCHES ARE ADDED TO ANY PORTION OF THE SUITE,REPLACE ALL EXISTING LIGHT SWITCHES WITH NEW (SEE DETAIL 3/A301) BUILDING STANDARD OCCUPANCY SENSOR SWITCHES. F. REMOVE AND SALVAGE FIRE EXTINGUISHERS&CABINETS FOR REUSE. PROVIDE AS E. PATCH AREAS ADJOINING AND/OR ADJACENT TO DEMOLITION WORK TO MATCH EXISTING AND/OR NEW CONSTRUCTION. ° ° RELITE PARTITION REQUIRED BY CODE, F. SOUND CAULK ALL WALUGLASS&WALUMULLION JOINTS. NEW OR RELOCATED BUILDING STANDARD DOOR, NEW FRAME,HARDWARE AND RELITE WHERE SHOWN • G. PROVIDE NEW BUILDING STANDARD FLOORING WHERE INDICATED ON PLAN&RUBBER BASE(RB-1)TO MATCH EXISTING AT NEW WALLS AND AFFECTED AREAS. PROVIDE CARPET TILES TO MATCH EXISTING WHERE WALLS WERE REMOVED. PAINTED ACCENT WALL .� a H. REPAINT ENTIRE SUITE UNLESS OTHERWISE NOTED-ASSUME 25%OF WALLS TO BE AN ACCENT COLOR. 0 (LOCATIONS TBD) DEMO PLAN KEYNOTES g I. WHERE NEW DOORS,FRAMES,HARDWARE&RECITES ARE PROVIDED,MATCH EXISTING BUILDING STANDARD TYPE,SIZE, BELOW ITEMS SHOWN FOR REFERENCE ONLY FINISH&COLOR. TOUCH UP EXISTING FRAMES&DOORS WHERE NEEDED TO APPEAR AS NEW. O. REMOVE EXISTING SINK/FAUCET. S SWITCH SHEET TITLE: 8 J. PROVIDE J-BOX AND PULL STRING FOR TENANT-SUPPLIED VOICE&DATA. D2 REMOVE WALLS AS SHOWN. REMOVE AND SALVAGE DOORS,FRAMES,HARDWARE AND FLOOR PLAN KEYNOTES S SWITCH-OCCUPANCY SENSOR Demolition on p IE RECITES FOR REUSE. & 05 p TELE/DATA OUTLET D3 REMOVE EXISTING FLOORING IN THIS ROOM-SEE FLOOR PLAN FOR MORE INFORMATION. DUPLEX OUTLET Floor Plans R 0 PROVIDE NEW CARPET TILES TO MATCH EXISTING AT EXISTING CONCRETE FLOOR. A 41= QUAD OUTLET 0PROVIDE NEW BUILDING STANDARD SST DISHWASHER. MODIFY CASEWORK AS NECESSARY AND PROVIDE POWER. FLOOR OUTLET 0.7 i 0 PROVIDE NEW STAINLESS STEEL SINK AND GOOSENECK FAUCET. m JUNCTION BOX 1= PROVIDE NEW BUILDING STANDARD SOLID CORE WOOD DOUBLE DOORS WITH FULL GLASS KIT IN EACH DOOR. PROVIDE THERMOSTAT v=/ BUILDING STANDARD HARDWARE AND CLOSER. 3 BLANK OUTLET DRAWN BY: DRM 5 V PROVIDE NEW LVT FLOORING&RUBBER BASE TO MATCH EXISTING AT BREAK ROOM. s E EXISTING DATE ISSUED: 1 GC TO CONFIRM THE DEDICATED HVAC UNIT IN THE EXISTING SERVER ROOM IS IN GOOD WORKING CONDITION. PROVIDE N NEW PRICE TO REPAIR AND I OR REPLACE IF NOT, R RELOCATED\-'—'7PERMIT SET 05.18.18 7 DOORS AT EXITS TO SWING OUT IN THE PATH OF EGRESS. PROVIDE NECESSARY MODIFICATIONS. AT CORRIDOR SIDE, FEC FIRE EXTINGUISHER CABINET REVISED PERMIT SET 05.24,18 i PATCH AND PAINT WALL;PROVIDE CARPET AND BASE TO MATCH EXISTING AND PROVIDE NEW SUSPENDED CEILING GRID FE FIRE EXTINGUISHER 1 SYSTEM AND PANELS TO MATCH EXISTING. • - $� PROVIDE NEW PARTIAL HEIGHT WALL. �SSI 6-29 t1 -4-- / d DEDICATED1 0 INFILL OPENING TO MATCH ADJACENT SURFACES. g.' A201 xi, 1PROVIDE POWER FOR TENANT-PROVIDED CUBICLES AT WALLS OR AT CEILING FOR TENANT-PROVIDED POWER POLES. SHEET: k. 10 VERIFY ELECTRICAL REQUIREMENTS AND LOCATIONS WITH TENANT PRIOR TO CONSTRUCTION. LRS Architects,Inc.0 2018 0 PROVIDE TWO SEPARATE CIRCUITS IN THE NE CORNER OF SERVER ROOM. § A 4 LnS ARCHITECTS 720 NW Davis 503.221.1121 u { / Ir II 1T , kr Suite 300 503 221.2077 ❑ Portland OR 97209 www.frsarchitecfs.cOrn • 7/ ic , ' • IIII • 1 � • g------ -- . L_____. „...01) % „ , , ,, ,.... , „ v i _ • / fi i, / • _ • 77 • 7/_ • • •z / • t A-- �- • • • __ 4:_,/ ,, r ,t „ „ , 7 7 / / / / [ c...7 -a I! \ �1 S ,_„., i a IIICHEILE C.SIARIT • r--- _ /i \ /1 \ /1 1 .= _ 7 . • 7 A 11—.--k U-,–.-4. 1 1 T ' V I I V I I V I I I A I I A I I A I I I /1 .r AtthidW-7:3 1 • •rfk PCSIL 1I,OREGON -=— • • • • 0 0 / • / • • 7 /7X/ fI I 6355 I 7 7 7 7 777 /7 \\//ra I / X7 Z-S 1 7 7 ^k- / 7 7 1 / • / -� — 777/7 I CONSULTANT: IV G7 7 • ..........._,• 7 7 / I 7x 7 _ IA 1/ 7----- --I • • • • • • • • N7x / 1 O FS _ - — AE FS V� lid_____ _1 7 7 7 L . Pr 7 A — 7_ � I 3 I f 77 7 7 / II _, Z • • • 1 • • • lig i _;,,47 • ` • �-x7 7 Z ,,, 7I1 7 xi ,,U �,,, „, ___, I •• /7 • 7 • • • II / / 7 7 / . • __ q �- II • zI , 7 I ' I/7 / 7 ,x/z . FS Xs / 7>: / F5 --, , �l F] ,. ” u U " 0 I IT JL PROJECT NUMBER: 218187 N N PrimePay T.I. 1. REFLECTED CEILING DEMOLITION PLAN (ID 2. REFLECTED CEILING PLAN SCALE: 1/8"= V0" SCALE: 1/8"= 1-0" Atrium West RCP GENERAL NOTES LEGEND 9600 SW Oak Street (1) DEMO RCP GENERAL NOTES Suite 380 A. REFER TO SHEET A100 FOR A COMPLETE LIST OF GENERAL NOTES. A. REFER TO SHEET A100 FOR A COMPLETE LIST OF GENERAL NOTES, EXISTING 2X4 ACOUSTICAL SUSPENDED CEILING Tigard, Oregon 97223 B. CEILING CONFIGURATION TO REMAIN UNLESS OTHERWISE NOTED. B. ALL ELECTRICAL WORK IS DESIGN BUILD-EXISTING&NEW LIGHT FIXTURES SHOWN FOR REFERENCE ONLY. EACH ENCLOSED ROOM TO HAVE A MIN.OF(1)2x4 RECESSED LIGHT EXISTING HVAC SUPPLY C. ALL ELECTRICAL WORK IS DESIGN BUILD- EXISTING LIGHT FIXTURES SHOWN FOR FIXTURE PER 100 SF-PROVIDE AS REQUIRED. SUBMIT ELECTRICAL PLANS TO ARCHITECT REFERENCE ONLY. VERIFY EXISTING CONDITIONS AND REPORT ANY DISCREPANCIES TO FOR REVIEW PRIOR TO CONSTRUCTION. CLEAN&RESTORE ALL LIGHTS TO WORKING ORDER /I ARCHITECT. PRIOR TO JOB COMPLETION. / EXISTING HVAC RETURN D. ALL MECHANICAL WORK IS DESIGN BUILD-EXISTING DIFFUSERS SHOWN FOR REFERENCE C. ALL MECHANICAL WORK IS DESIGN BUILD-EXISTING DIFFUSERS SHOWN FOR REFERENCE ` EXISTING BUILDING STANDARD LIGHT FIXTURE ONLY. VERIFY EXISTING CONDITIONS AND REPORT ANY DISCREPANCIES TO ARCHITECT. ONLY. VERIFY EXISTING CONDITIONS AND REPORT ANY DISCREPANCIES TO ARCHITECT. EACH ENCLOSED ROOM TO HAVE A MIN.OF(1)HVAC SUPPLY AND(1)HVAC RETURN- PROVIDE NEW OR RELOCATED BUILDING PROVIDED AS NEEDED. SUBMIT MECHANICAL PLANS TO ARCHITECT FOR REVIEW PRIOR TO STANDARD 2x4 LIGHT FIXTURE CONSTRUCTION. CLEAN ALL DIFFUSERS PRIOR TO JOB COMPLETION. rk;–"%'1 EXISTING LIGHT FIXTURE TO BE REMOVED OR D. ALL FIRE LIFE SAFETY IS DESIGN BUILD. SUBMIT PROPOSED LOCATIONS FOR EMERGENCY 4'---i RELOCATED LIGHTING,STROBES,SMOKE DETECTION&SPRINKLERS TO ARCHITECT FOR REVIEW AND COORDINATION PRIOR TO CONSTRUCTION. I-- -- '1 EXISTING SUSPENDED LIGHT FIXTURE E. REPLACE ALL DAMAGED CEILING TILES&GRID TO MATCH EXISTING BUILDING STANDARD. ® ®+ EXIT SIGNS(WI INTEGRAL ARROW WHERE OCCURS) F. WHERE NEW LIGHTS ARE ADDED-MATCH EXISTING BUILDING STANDARD TYPE AND FINISH. • EXISTING SPRINKLER +B'-10 CEILING HEIGHT AFF 0 RCP KEYNOTES SHEET TITLE: O FSI EXISTING FIRE STROBE Reflected Ceiling 1:1- 1 PROVIDE NEW BUILDING STANDARD EXIT SIGN TO MATCH EXISTING. I .411111111111 PATH OF EGRESS SHOWN FOR REFERENCE ONLY /2 PATCH SUSPENDED CEILING GRID TO MATCH EXISTING AT CORRIDOR WHERE WALL WAS ED. (DEFERRED SUBMITTAL) Plans U S S D CI c g O DRAWN BY: DRM E DATE ISSUED: m PERMIT SET 05.18.18 A REVISED PERMIT SET 05.24.18 E a co 5 W F. C A 202 _ ,1 a „ SHEET: 2 N LRS Arehltects,Inc.0 2018 E IX on M N 4 7; 4,0111MMENIMIF _401111111114 - 1 N414=NOMml -; i11111114111111111411110111111, 1/8"COVER PLATE CONTINUOUS TRACK WITH ARCHITECTS 18 GA.DEFLECTION CHANNEL FASTENER TO TOP PLATE 1/8"STEEL 720 NW Davis 503.221.1121 PROVIDE(2)#8 SHEET METAL PATCH FIRE SECURE TO METAL DECK W/ tit SCREWS AT EA.BRACE PROOFING 114"DIA.X 1-1/2"POWER ATTACHMENT TO STRUCTURAL 20 GA.3 5/8"STUD BRACING TO \--- ACTUATED DRIVEPINS INTO BACKER RODS Suite 300 503 221.2077 0 MEMBER TYP. STRUCTURE @ 8'-0"O.C. CONCETE FILLED FLUTES @ 18" AND CLEAR SEALANT EXISTING WINDOW MULLION Portland OR 97209 wwW.lrsarchitects,com ZVI/ PROVIDE 2"X 1/8"LIGHT&SOUND 9 O.C. OR#8 S.M.S INTO METAL a 3-5/8'25 GA.(3625125-18)MTL PROVIDE CORNER BEAD SEALING GASKET CONTINUOUS DECK @ 18"O.C. PROVIDE FOR STUDS @ 24"O.C.WITH 5/8"GYP. &PAINT ON WINDOW SILL BELOW CONTINUE 314"DEFLECTION. BD.EACH SIDE SIDE OF WALL END, BETWEEN WALL&CEILINGI40 GYP.BD.TO r CEILINGPICAL n HSS HEIGHT ��� )4 VERIFY HEIGHT �j SEE RCP --�/�- - FULL HEIGHT �$•x s'X 338• -"" PROVIDE 3x3x1/8 HSS TUBE STEEL 02 0 CEILING SYSTEM AS SPECIFIED BASE ATOlk TW HEN SUPPORTS AT 48"O.C.INSIDE ` j, PROVIDE(2)FASTENERS @ EA. 00 WHERE OCCURS(REFER TO HD 11-14-5, = EXPOSED WALL ENDS TO FULL WALL c.SST C BRACE STUD CONNECTION TO TOP i RCP) SECTION A HEIGHT AND MOUNT TO FLOOR WITH OF WALL STUD 0 z 3/8"PLATE STEEL. If 0 0 3-5/8"25 GA(3625125-18)MTL u. i 6, STUDS @ 24"O.C.WITH 5/8" GYP. w N { r'.: .t 5/8"25 GA.(3625125-18)MTL SD.EACH SIDE. EXTEND MTL > r GLAZING 6355 STUDS 24"O.C.WITH 5/8"GYP. 0 STUDS AND GYP.B . FULL HEIGHT PARTITION TYPE AS •• "e.i W ablr 3 Wr BD.EACH SIDE. PROVIDE 3"SOUND s TO UNDERSIDE OF STRUCTURE " SCHEDULED ATTENUATION BATT INSULATION _ ABOVE. PROVIDE 3 SOUND POWDER DRIVEN ANCHOR AT 2-0 FRICTION FIT IN STUD SPACE AND ATTENUATION BATT INSULATION O.C.THRU MTL.STUD TRACK,UON i FRICTION FIT IN STUD(SEE NOTE ACOUSTIC SEALANT @ CEILING ���1 1 GRID. ;!+ i* BELOW FOR MORE INFORMATION). SECTION A � POWDER DRIVEN 1)0.41 POWDER DRIVEN ANCHOR " yrs CENTER OF MULLIION TO • ANCHOR AT 2-0O.C. a, I / I ALIGN WITH CENTER OF CONSULTANT: AT 2'-0"O.C.THRU MTL. THRU MTL.STUD '!� BASE ON BOTH SIDES AS BASE ON BOTH SIDES AS SPECIFIED tti STUD TRACK,LIONPARTITION BASE ON BOTH SIDES AS �ti TRACK,UON �i�i SPECIFIED SPECIFIED ;~ ((;~ ;�1 EXISTING SLAB (Ii _ EXISTING SLAB • ___ EXISTING SLAB NOTE: FOR WALLS 13'-6"ABOVE FINISHED FLOOR(AFF)BUT LESS THAN 16'-1"AFF,PROVIDE 3-5/8"20 GA (3625200-33)STRUCTURAL MTL STUDS WITH 2"FLANGE AT 24"O.C. FOR OTHER CONDITIONS,VERIFY WITH ARCHITECT PRIOR TO CONSTRUCTION. . I. BUILDING STANDARD PARTITION 2. DEMISING WALL 3. PARTIAL HEIGHT WALL 4. WALL TO MULLION DETAIL SCALE: 1/2"= 1'.O" SCALE: 1/2"= 1-0" SCALE: 1"= l'-0" SCALE: 3"- 1'-O" PROJECT NUMBER: 218187 PrimePay Ti. Atrium West 9600 SW Oak Street Suite 380 Tigard, Oregon 97223 a, SHEET TITLE: a Q Interior Details 0. co co6 g g ci I 4 g DRAWN BY: DAM .. DATE ISSUED: PERMIT SET 05.18.18 a A REVISED PERMIT SET 05.24.18 E ! co s 1 A301 .. SHEET: i N LRS Architects,Inc 2018 E. n ri