Loading...
Plans (381) BU P2018 - 00131 cAREG (:) .!, ,I, REPRODUCTIVE MEDICINE Z F ARCHITECTURAL SYMBOLS PROSECT GENERAL NOTES OFFICE COPY ZIMMER GUNSUL FRASCA ARCHITECTS LIP A. DIRECTION VIEWED 1. REVIEW ALL CONSTRUCTION DOCUMENTS AND COMPARE THEM TO FIELD CONDITIONS PRIOR TENANT IMPROVEMENT � ' � INTERIOR ELEVATION IDENTIFICATION SHEET WHERE ELEVATION IS DRAWN TO PROCEEDING WITH THE WORK. IMMEDIATELY REPORT ANY CONFLICTS, DISCREPANCIES PORTLAND rr" OR OMISSIONS TO THE ARCHITECT. SEATTLE LOS AGELES 2. ALL WORK, BOTH NEW AND IN PLACE, IS TO MEET THE REQUIREMENTS OF APPLICABLE WASHINGTON DRECEIV E ink DETAIL IDENTIFICATION CODES, REGULATIONS AND AUTHORITIES HAVING JURISDICTION, INCLUDING BUT NOT LIMITED NEW YORK REDROCK MEDICAL BUILDING C A6.1 SHEET WHERE DETAIL IS DRAWN TO THE LATEST EDITION OF THE INTERNATIONAL BUILDING CODE(IBC) AND THE AMERICANS APP 3 2-013WITH DISABILITIES ACT(ADA). MEET THE FIRE PROTECTION AND LIFE SAFETY REQUIREMENTS CITY OFTIGARD 0 COLUMN GRID IDENTIFICATION OF THE LOCAL JURISDICTION, INCLUDING BUT NOT LIMITED TO THE DOCUMENTED PROJECT gUILD1NG LIFE SAFETY SUMMARY. 12115 SW 70TH STREET • SHEET NOTE REFERENCE 3. PROVIDE ALL WORK REQUIRED FOR A COMPLETE INSTALLATION WHETHER OR NOT SHOWN OR DESCRIBED. Q, REVISION NUMBER 4. ALL PORTIONS OF THE BUILDING OUTSIDE THE SCOPE OF WORK WILL REMAIN OPEN TO SUITE 101 ® OCCUPANTS. COORDINATE THE MOVEMENT OF PERSONNEL AND MATERIALS WITHIN FIRE EXTINGUISHER BUILDING, ON SITE AND SIMILAR AREAS WITH THE BUILDING OWNER'S REPRESENTATIVE. Revisions MAINTAIN EXITING, FIRE PROTECTION AND LIFE SAFETY PER FIRE MARSHALL'S OFFICE. ROOM NAME ROOM IDENTIFICATION TIGARD, OREGON 97223 01 ROOM NUMBER 5. PATCH, CAULK AND FINISH ALL THROUGH FLOOR, WALL AND CEILING PENETRATIONS OF . 1 WHERE WALL OCCURS (TYP. U.N.O.} CONDUIT, PIPING, DUCTS, ETC FOR SMOKE TIGHT ASSEMBLIES. /1'r-.i" (VERIFY HARDWARE CLEARANCE) 6. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. WHERE WRITTEN DIMENSIONS ARE PROJECT INFORMATION DRAWING INDEX _I . TO NEAREST OBSTRUCTION, PULLSIDE NOT INDICATED OR ARCHITECT FOR CLARIFICATION.CATION DIVISION DISCERNED FROM THE DRAWINGS, CONTACT THE + (12 ALLOWED ON PUSH SIDE OF DOOR) BUILDING: RED ROCK MEDICAL BUILDING C ARCHITECTURAL DOOR IDENTIFICATION 7. REFER TO SUB-CONTRACTOR'S DESIGN BUILD DRAWINGS FOR BASIS OF DESIGN FOR DOOR NUMBER RELATES TO MECHANICAL, ELECTRICAL, PLUMBING AND FIRE LIFE SAFETY SCOPE OF WORK LOCATION: 12115 SW 70TH STREET, SUITE 101 A0.0 PROJECT INFORMATION, DRAWING INDEX, SITE PLAN, PROJECT GENERAL ROOM NUMBER MAP AND TAX LOT ID# 25101 AB, 03100 NOTES 8. COORDINATE PLUMBING WITH APPROVED CASEWORK SHOP DRAWINGS, ARCHITECTURAL ZONE: C-G GENERAL COMMERCIAL DISTRICT A2.0 FLOOR PLAN, FIRE LIFE SAFETY PLAN, BUILDING SUMMARY EXISTING 1-HOUR RATED WALLS DRAWINGS, AND ALL OTHER TRADES PRIOR TO INSTALLATION. A2.1 POWER AND COMMUNICATION PLAN, REFLECTED CEILING PLAN CONSTRUCTION: TYPE VB, FULLY SPRINKLERED EXISTING WALLS 9. REFER TO DETAIL SHEETS A8.3 FOR STANDARD CEILING DETAILS U.N.O. B OCCUPANCY A7.0 INTERIOR ELEVATIONS, ACCESSORY SCHEDULE A7.1 INTERIOR ELEVATIONS '4,14,..--,,,,,,m,--,,,,-,,, NEW FULL HEIGHT PARTITION AREA OF WORK: 3,423 SQUARE FEET ON FIRST FLOOR A8.0 FINISH LEGEND AND SCHEDULES, DOOR SCHEDULE 10. PROVIDE ALL REQUIRED ELECTRICAL WORK FOR AREA SHOWN. WORK INCLUDES ALL A8.1 INTERIOR DETAILS RELITE - SEE INTERIOR ELEVATIONS REQUIREMENTS FOR HVAC, PLUMBING AND FIRE-LIFE SAFETY. CONTRACTOR TO OWNER: TIGARD TRIANGLE PARTNERS, LLC A8.2 INTERIOR DETAILS COORDINATE ELECTRICAL INSTALLATION WITH ALL OTHER TRADES. A8 2115 SW 70THSTREET, SUITE 200 .3 CEILING DETAILS 1 12115D, OR S PARTITION TYPES -- SEE A8.1 11. TEST EXISTING CONCRETE AND NEW CONCRETE TRENCH POUR BACK LOCATIONS FOR TIGASTEVEN GABLE, FACS MOISTURE CONTENT. VERIFY IT IS COMPLIANT WITH FLOORING MANUFACTURERS MINIMUM EMAIL:CONTACT:drgabel@gobeicenter.com MD, BIDDER DESIGNED SYSTEMS: REQUIREMENTS. IF EXISTING CONCRETE DOES NOT MEET REQUIREMENTS, PROVIDE g SEALANT AS RECOMMENDED BY MANUFACTURERS. TELEPHONE: 503-887-7477 --MECHANICAL NOTE: ALL DIMENSIONS ARE TO FINISHED FACE OF WALL, U.N.O. -PLUMBING 12. PROVIDE FIRE EXTINGUISHER AT THE RATE OF ONE PER EVERY 3,000 SF OR FRACTION TENANT: OREGON REPRODUCTIVE MEDICINE, LLC -ELECTRICAL THEREOF PER SECTION 906 (OFC). EXTINGUISHERS TYPE 2, A10, BC. LOCATIONS SHOWN 808 SW 15TH AVENUE -FIRE SPRINKLER ON FLOOR PLAN AND LIFE SAFETY PLAN. PORTLAND, OR 97205 -FIRE ALARM AND SMOKE ALARM SYSTEM CONTACT: CAREY TOMBERG, FACILITIES MANAGER ABBREVIATION 13. PROVIDE TACTILE EXIT SIGNS COMPLYING WITH SECTION 1107.5, SECTION 1011.3 (OSSC) TELEPHONE: 503-290-1535 THE GENERAL CONTRACTOR SHALL COORDINATE AND ASSUME COMPLETE ADJACENT TO EACH EXIT DOOR. EMAIL:ELEPONE. 503-290- 535 RESPONSIBILITY FOR DESIGN, ENGINEERING, SUBMITTALS, FABRICATION, TRANSPORTATION, AND INSTALLATION OF THIS WORK. cL CENTERLINE PRIOR TO STARTING WORK, THE GENERAL CONTRACTOR SHALL SUBMIT ALL ADJADJUSTABLE GENERAL HOWARD S WRIGHT CONSTRUCTION, INC BIDDER-DESIGNED DOCUMENTS TO THE GOVERNING BUILDING DEPARTMENT FOR AFFFF ABOVE FINISH FLOOR CONTRACTOR: 1455 NW IRVING STREET, SUITE 400 CLR CLEAR OREGON REVIEW AND APPROVAL. EACH BIDDER-DESIGNED ITEM MAY REQUIRE A SEPARATE PORTLAND, OREGON 97209 PERMIT AND FEE, WHICH SHALL BE PAID BY THE CONTRACTOR. CLG CEILING CONTACT:NICK STEERS, PROJECT MANAGER TEL: 503 601-9939 DIA DIAMETER REPRODUCTIVEAFFIX DESIGN PROFESSIONALS' SEAL OF OREGON STATE LICENSE ON ALL EMAIL: steersn@hswc.com SUBMITTALS WHERE REQUIRED BY CODE. (E) EXISTING EA EACH MEDICINE ARCHITECT: ZIMMER GUNSUL FRASCA ARCHITECTS, LLP ALL BIDDER-DESIGNED WORK SHALL BE PROVIDED TO THE ARCHITECT AND EQ EQUAL SUITE 1 01 1223 SW WASHINGTON STREET, SUITE 200 PORTLAND, OR 97205 BUILDING OWNER FOR REVIEW PRIOR TO PROCEEDING. EQUIP EQUIPMENT CONTACT: JAN ECKELMAN GYP GYPSUM BOARD TEL: (503) 863-2263 HM HOLLOW METAL TIGARD, OREGON EMAIL: jan.eckelman©zgf.com ID INSIDE DIMENSION MAX MAXIMUM _ _ _ _ _ MIN MINIMUM N/A NOT APPLICABL prar,yingTitle SW DARTMOUTH STREETNICNOT IN �'� NTS NOT TO ALE CONTRACT .�� ! a ;'.: -. ."--•- -=,.�- �■ PROJECT INFORMATION Lit I 1►�� is OC ON CENTER DRAINING INDEX B�"°'"GB BUILDINGA OD OUTSIDE DIMENSION :i,'..:. MEDICl4L OFFICE-L,EtY ds 11,110 90 F7 4 unity , UFFCE.,,.„� OFCI OWNER FURNISHED CONTRACTOR INSTALLED L SITE PLAN Pi •,. � � ®,;_ -� � I OFOI OWNER FURNISHED OWNER INSTALLED wEfiiv�io:: --- b - LAM PROJECT GENERAL NOTES PL P PLASTIC LAMINATE ' RESERv� I �� �, b► b SIM SIMILAR ,`,; �....� • I _ OFFICE COPY FY. - `° ¢, SS STAINLESS STEEL F TYP TYPICAL CITY of TIGARD -• g' I _ _ _.._ �..-_ �'� . I UNO UNLESS NOTED OTHERWISE REVIEWED FOR CODE COMPLIANCE - .ni . ....................... ___._ _. _. _ b 1 A raved• ii _ _ VEY VERIFY IN FIELD S] iApprover-14 r , i ,-,w,s,i� W/ WITH I j DTC: Gtr t�� j+fs G , , c..140j) M '� �� �� �N�=''� •,.. W/O WITHOUT Per it#: .ii 1 ,_nj•tom- r)C7 Iinrl R• 3.3'5nberg �' j). l��' Sty 7, M �. S�iitc #: p BUILDING C- . \ / 1 >E� r j 1 111 °� BY: Date: -7 - o •,�{rLAMD, OREGON s:.. i 1 •,1 il I ui i air-',. 1 „.,, / t I ‘1.1Zs oF ortL. ' E3 / Wil. � I I I 1 Project ,�- ,, I Date:_ Job No: P24144.01 Location I ; I I , I= Drawn By: JAN ECKELMAN c a, r I Checked By: CLAUDIA BTYRSKY % E-5 I "i 44 V( 1 1 I a) - t 1 I CD • a> j / / / o ° Ask.," I 4' Drawing No. o E - - _ - __.. 0ELMHURST ST.DEDICATION o 1 �- to oN 3�r I._ +ppn .vo„, Alii iell 9 i � �L7ARD AO . 0 . ,_•<.,1 ' 1 SITE PLAN Approved by Planning . o d A.0 SCALE: NOT TO SCALE Mr Date: I�'° I� 4. O Initials: 'IvPERMIT SET N f- o © 0 o © I - r- ZG F r I � PROJECT AREA OF WORK T 2'-4 3 4" 1 E 7 F 1 f 8xi 7 Q' :-1 O _ -__— _ — _ ZiMMER GUNSUL FRASCA ARCHITECTS LLP WV L../ tNi. --7 MIMI= —--------1 ._,KrErli> -, i. . toii..rej Iv i t PH OFF TEACH TEAM 1 O' FI E ,LIGN PORTLAND © 107 4> 104 10 SEATTLE 7'-5" "64 � LOS ANGELES 0" °, o '- . o o '-i" I 100A WASHINGTON DC —i,:_ -7,_.-:,-1_- ;ww�0" — .�_ i`- `� - I NEW YORK 1 s ,o \ALIGN/ no © D H L 12'-6" 3_6 3 2 5'-7" WAITING 4112. 0 0 0 0 0Q Q 11)5 , 100 - �... _. - - --t --V- _ O �v 1 AUGJ PROJECT AREA OF WORK f- I — — — — — — ! TEA 2 i --. . . _ .. • I 100 �,�_. .. .. .. .__...:w. ____:_•rr.:...Y r_=:_ ==�..--,_-��.--. ---,,,,�,- -- -<-..__..wa .— - -- l.-11-7•71 ----- _ ___-- - -- -- ,1, Q ....�_.�. �-- - _.--- . I 110 I o 0 r , rri ��� n ! I i al �1 �iy`ITIr ��} _• A- 1 :f' 4> 2 0 10 i --. O 122 rip—mtesi i fiai 1 I r TEAC 4 AD - �I - HALL < � PHLEB I • t 103 , � <'�> 101 .± , ---T--t' ., �j � 106 r� �.__—±..�..�'..-...__.__-_; jig '- $—6 r 101 II'-----4---14.1F �I l i � 111 7 $ -----I-- H o / r —Q— - - -._ _ _ I O 111 BREAK ril . �r >.� - --;,' - -- 1ALIGN�� _� r r �;�' °1 113 2 -. :�i�•�.�!R� U 29 s 1•1--1----M• ' ��--.�� __ --_ Revisions ' _ S i `_., LI s 2f�6,f a, 10" 5' 4" I� Is _= 11 ( HAL �; ; [g , i �► ��� --IEXIT I A NA I > TIL 'G� �_i 124 in 4 --- J Qit-Lt-I L-------- .._ Q '13-6 _ , ` iitj Ir- .a ' i3 6 ;I - ., 1 ;3 - �-• a e 114 `� 125 " -- , i H 1 LL ,. ©UL A t'►1 ,I 1 Ire `} # '! ' : �+� �� 1' ;'.1 ' II� ■ 1 ; <�. = = - Q I 114 Q .. x �- av Sp © e Q ,I. , � 57 FEET=' 1 _.. 116 ire " 11 'C r!I - _�_. �n 1 •� " � 126 -6 ;I -;= 17--=-------==. t ,�/l 1 at LIMN! 1A 6 11 t�► ;; OLL J - Ali .;_ ... . mi _�.---_ - _... ---- -, ..--- _ -si � .— � - Q i - •► -s « � .ice � 11 ! :A, , . ,, lArk �y! rs. i li.l .... : lis .- ,7==_,-...-_,===._!_ --f �' ^. Y I .. I b•. TIL— a. .... � • 26� -�1� I .., • .- 'LEI �I 1 �f~©LM ...... .... _ --,,,...J:- , it 1 cewcOs 1 i :-_-'___...._..__,..._�., f I it i, I ... i.l 1 _ , —1-111-1.- s- _._ i - vvid 127 - �1 I Ii ! !I I f _-01 'Ta; iI 'I 11 a I -h- ru, © + • 1 �h ��.r' ' _ u� II I It V rY } — 1 I rl ; I ' _ L .il _.� #i '"• i _ F Q — -- WI �- aD R "� ...� 1 ii I , �' ���' I' °° �!� HALL LT © _ ' �� _ _ �� Int: _ 1 �" S I SD - - - 6 _ 1 �i •• n® 1 ., nce ., I-I-_ -ii �-I� II I 1 ---_.. o 118 't2 f D i 1.1_ 1 "----- T01 L ,-17. r----,-- r, ,L i likw = 118 i - C� Fr ♦ t19 / ii!JiNew I _mss :� .. ��r x �_1.,-- �n�, - - .-;m ---fw__; � rz.--_, -=..._Ir . __ _ ------ .-...-- 1st. - - . 11 S. Emiimial II , i I • I ' + ____ i, ; _ - , 0 120 a -"I l ,I I ! ANDROL WI 1 t ;� f' i, iip LTR d 128 I �i I • I ; 1 I I !; II !ti_ II OFFICE o �D SD .© I <.�61,> I; i' ij i �- - � - - - r I II II I 120 4' 121 121 '' I ; ;I i 9' 11" - IW-..,„_ 2- Illa-g-,.1.- !! wir L J I © �_..-. ..p..._ . „".,.._.______.•._...„,......,___,__p ...___..._._..- ___�:la.-.=._ __ -„.'�____�___] �� ,PROJECT AREA OF WORK I I 1 4'--6" [L:s:f.±:„7„Ea„_._.[ li ____________ lir PROJECT AREA OF WORK T 2 FIRE LIFE SAFETY PLAN - FIRST FLOOR ' 1 FLOOR PLAN - FIRST FLOOR Air � iii , A2.0 SCALE: NOT TO SCALE A2.0 SCALE: 1/8" = 1'-0" FLOOR PLAN GENERAL NOTES 1. ALL INFORMATION SHOWN IS TO BE NEW, THIS IS A FIRST GENERATION BUILD OUT OF THIS SUITE IN A NEW OREGON BUILDING. CONFIRM WITH OWNER IF ANY SHELL FINISH WORK IS TO BE INCLUDED. �+ ` I 2. ALL TENANT INTERIOR PARTITIONS TO EXTEND 6" PAST THE FINISHED PLANE OF THE CEILING. TYPICAL PARTITION REPRODUCTIVE E CODE SUMMARY FOR TENANT IMPROVEMENT SUMMARY - PLUMBING FIXTURE COUNT TO BE TYPE 1, SEE DETAIL 1/A8.1. TYPE 2 PARTITION(SEE DETAIL 2/8.1), FULL HEIGHT WITH SHEETROCK TO MEDICINE UNDERSIDE OF STRUCTURE AROUND ALL WALLS OF ALL ULTRASOUND ROOMS, COLLECTION ROOM 126, i NEW WALLS OF PHYSICIAN OFFICE 109 NOTED ON THE FLOOR PLAN. ALL WALLS IN ROOMS WHERE SYMBOL O OCCURS. SUITE 101 REFER TO SHEET A8.1 FOR WALL DETAILS. TOILET PLUMBING WALLS TO BE 6" DEEP, 8" WHERE TOILE 'RE BACK EXISTING NEW PLAN AMOUNT TO BACK. FINISH ALL EXTERIOR WALLS REFER TO DETAIL 3/A8.2. USE 1-5/8" STUDS FOR EXTRA SPACE REQUIRED TIGARD, OREGON BUILDING CODE: 2014 OREGON STRUCTURAL SPECIALTY CODE FOR ELECTRICAL OUTLETS AT EXTERIOR WALLS OF TEAM 104, TEAM 110 AND ANDROLOGY 128. PROVIDE SHEETROCK 0 SINKS, LAVATORIES OR TOILETS 8 SINKS WRAP AT ALL WINDOW SILLS. BUILDING STORY: TWO STORY IN THIS VACANT SHELL SPACE 4 LAVATORIES OCCUPANCY GROUP: GROUP 'B' 4 TOILETS 3. MAINTAIN RATING OF EXISTING 1-HOUR WEST STAIR ENCLOSURE BY FURRING OUT EXISTING WALLS IF NECESSARY. 3 WATER LINES TO 2 WATER DISPENSERS 4. WHERE TRENCHING IS REQUIRED FOR PLUMBING OR ELECTRICAL AT MA 108, POUR BACK IS TO MEET 3000 PSI CO Drawing'Die CONSTRUCTION TYPE: TYPE VB, FULLY SPRINKLERED. AND 1 EYE WASH 28 DAYS. PROVIDE #4 REBAR AT 18" O.C. DOWELED INTO CONCRETE WITH 2 #4 BARS RUNNING PARALLEL TO TRENCH. PROVIDE CONCRETE DESIGN SUBMITTAL FOR REVIEW WITH BUILDING STRUCTURAL ENGINEER. FLOOR PLAN TOTAL BUILDING TENANT AREA: 21,000 SQUARE FEET 5. INSULATION MATERIALS TO MEET FLAME SPREAD INDEX OF NO MORE THAN .25 AND A SMOKE DEVELOPED INDEX FIRE LIFE SAFETY PLAN SUMMARY OF WORK: PROJECT CONSISTS OF A SINGLE TENANT, 3,423 S.F. TENANT OF NO MORE THAN 450 PER SECTION 719 (OREGON SPECIALTY STRUCTURAL CODE) IMPROVEMENT BUILD-OUT IN AN EXISTING SHELL BUILDING. OCCUPANCY TO BE MEDICAL BUILDING SUMMARY OFFICE BUSINESS GROUP B. THIS IS NOT AN AMBULATORY CARE FACILITY, THERE ARE 6, ALL DIMENSIONS ARE TO FINISHED FACE UNLESS NOTED OTHERWISE. NO PATIENTS THAT WILL BE RENDERED INCAPABLE OF SELF--PRESERVATION. ' 7. PROVIDE REINFORCEMENT IN PARTITIONS AS REQUIRED FOR ANCHORAGE OF CASEWORK AND ANY WALL SUPPORTED EQUIPMENT OR ACCESSORY. OCCUPANT LOAD AND EXITING 8. PROVIDE ANCHORAGE FOR WALL MOUNTED SINKS AND GRAB BARS TO WITHSTAND A 250 LB APPLIED VERTICAL LOAD ON THE FRONT EDGE OF THE FIXTURE. OCCUPANT LOAD: 37 9. CONTRACTOR TO PROVIDE ACCESSORIES MEETING ADA REQUIREMENTS AT ALL TOILET ROOMS AND THE COLLECTION �� MINIMUM NUMBER OF MEANS OF EGRESS REQUIRED PER OCCUPANCY: 1 NUMBER PROVIDED: 2 ROOM. MIRRORS TO BE TENANT PROVIDED AND CONTRACTOR INSTALLED IN ROOMS DESCRIBED IN ACCESSORY 2335 (SEPARATED BY AT LEAST - 1/3 THE DIAGONAL DISTANCE OF BUILDING) SCHEDULE, SHEET A7.0. ADA ACCESSORIES TO INCLUDE GRAB BARS BOTH VERTICAL AND HORIZONTAL, TOILET R. anberg rei TOTAL DIAGONAL DISTANCE: 91' (1/3 DIAGONAL DISTANCE = 30' MINIMUM) PAPER DISPENSERS, SEAT COVER DISPENSERS AND SEMI-RECESSED PAPER TOWEL/TRASH DISPENSERS AS SHOWN ON ACTUAL DISTANCE APART = 71' DRAWINGS. PROVIDE A WHITE PLUMBING SLEEVE AT LAVATORY DRAIN PIPES AND AT EXPOSED HOT WATER SUPPLY TRAVEL DISTANCE DOES NOT EXCEED 300 FT FOR FULLY SPRINKLERED BLDG LINES' RTUwo, OREGON ,�, cn 10. REFER TO ELEVATIONS ON SHEET A7.0 FOR SPECIFIC INFORMATION ON PLUMBING FIXTURES, ACCESSORIES. ' S TENANT SPACE BREAKDOWN PER TABLE 1004.1.2: 0 WAITING AREA (15 SF/OCC) 311 SF 20 (ACTUAL SEATS:10) 11. PROVIDE BUILDING STANDARD FIRE EXTINGUISHERS AT LOCATIONS SHOWN. OF 0g `1 EXAM ROOMS/XRAY/DRAW a cri (100 SF/OCC) 723 SF 7 12. PROVIDE CODE REQUIRED SIGNAGE AT TOILET ROOMS AND EXIT PATHS. OFFICES/WORK/MA (100 SF/OCC) 1,080 SF 10 a OOR PLAN SHEET NOTES: Q O -0 TOTAL OCCUPIED SPACE: 2,114 SF 37 PROVIDE COAT ROD AND SHELF IN COAT CLOSET CABINET, SEE INTERIOR ELEVATIONS FOR LOCATION OF ADA HEIGHT. Date: APRIL 23,2018 ix c IL LESS ACCESSORY USE SPACES: © PROVIDE A COLD WATER LINE ABOVE BREAK ROOM COUNTER FOR THE TENANT'S COFFEE MAKER, CONFIRM LOCATION. Job No: P24144,01 co° (HALLS, TOILET ROOMS, LACTATION RM, PROVIDE COLD FILTERED WATER AT BREAK ROOM SINK TO MATCH EXISTING SYSTEM INSTALLED AT ORM'S 808 BUILDING c BREAK ROOM AND UTILITY ROOM) . PROVIDE COUNTER MOUNTED EYE WASH Drawn By: JAN ECKELMAN Q o-0 ACCESSORY USE SUB-TOTAL -1,130 SF 4. PROVIDE 4'H ACROVYN CORNER GUARDS MOUNTED STARTING AT TOP OF 4" RUBBER BASE AT ALL OUTSIDE CORNERS. MATCH PAINT COLOR OF WALL. Checked By: CLAUDIASTYRSICY iE 'E of TOTAL 37 OCCUPANTS © COORDINATE INSTALLATION OF TEMPERATURE SENSOR AT UNDER COUNTER REFRIGERATOR COORDINATE WITH TENANT'S IT VENDOR. o - 'I EXITS = 3 EXITS PROVIDED, 1 REQUIRED. O Drawing No PROVIDE PRIVACY CURTAIN AT ENTRY TO PHLEBOTOMY E m o FRAME WALLS AS NECESSARY TO CHASE PLUMBING FOR TOILETS. INSULATE AROUND ALL PIPING. WRAP INSULATION AROUND PIPING AND Q E 0 O BETWEEN METAL STUDS AT FRAMING AROUND ROOF DRAINS AND WASTE DRAIN PRIOR TO INSTALLING GYPSUM BOARD `..“ Q 3'-0"W X DOOR HEIGHT INTEGRAL FRAMED RECITE, INSTALL GLASS FILM, WF 0 0PROVIDE BACKING IN WALL TO SUPPORT TENANT PROVIDED TV MONITOR IN COLLECTION 126 AND BABY CHANGING STATION IN TOILET 129. O.F.C.I. ,0oo y A2 . 0 2 Q'"--.- I ii FURR AROUND EXISTING STEEL COLUMNS, ROOF DRAINS, WASTE DRAINS AND OTHER PLUMBING. USING THE SMALLEST STUD SIZE POSSIBLE, WRAP Q d- E INSULATION AROUND PIPING AND BETWEEN STUDS FOR GREATEST SOUND PROTECTION. FINISH IN GYPSUM BOARD, PAINT AND INSTALL WALL BASE. i „ ° 4 EXISTING BUILDING FLOOR CLEAN-OUT/DRAIN, PROVIDE ACCESS AS REQUIRED FLUSH TO FLOOR FINISH. Ai � N PERMIT SET v 8 ® PROVIDE BLACK-OUT SHADES WITH FRAME AND LIGHT SEAL AT ULTRASOUND 121 INSIDE OWNER-PROVIDED BUILDING STANDARD WINDOW COVERINGS 0 0 s cli) Q 4 5 r 4 Q ® I Z F PROJECT AREA OF WORK + 1 A 1- 1- 1 r 1 r r PROJECT AREA OF WORK - llI 11 + ZI1vIMER GUNSUL FRASCA ARCHITECTS LLP 0 ��; I I I 1 I , , ,,-_ ,,,„: , . - II , ��� oC.11C .{, f nI 1 L PORTLAND pig FF i E',� in 0 FI I Clj ��►E !�► LRv= 'T sEATTI.E urwril ■ CH TAM1FICE -909 1 10vU!E!iJIEII!Ui!!i_ L ■ - 01 ("NI 100A ; (2) -E2-_-_:„. 1 * -__ \ .. �� ,, .I■►�■■■ i■ ■■■■■/�■11 ■ ■�I ___71:11 0 *- 110 HALL F WAITING ■`■`t��1��■■1; ■■■n■�■■1■■��■rl. :�I►�I■■ ■�f - 1 05 100 .i .. - * ...... ,_:_.^tea ■ i • SIrI.iIu;i �/ ------. � '� I jlI 7EQAM 2 r�► 1 as ' ,, YYI■■�■1', ��ih►.�� -4 - _ 46�= .. �1 1 ., ■ ®�' ■ .1111 ■.���� .�,���.' Iii i� I j �' :, M�, O � E :E-2CEP !I +illk HA III{�., .. ■�■�■� ■■E : 1112:6311111111 ■�_ ` , _ `,; ,Illi r'i 1 r-� ", iiv 1^u , _ � jNi_,_-'vr' I�- s �li HAL .;, ■� � .��,+��. � .; V I7TEACH 46 _ _ I, :' J LEB ;1 a3 �/ +#1....',I-■ i... _ �I' �=-t w�1 - HAL h > + - i■■■■■- f11 ■■�2 ■■■■ ■■�, L-8t �.� - I,I - ® 106 P03 1 h � -_ __�.I L�� ■�� ■A�■■ 11 11■■: iiia ..._ ,3;� k r�- Revisions 46 i,H�----:, III ■:11C»:1: 11■■ ::...' ., �; -46'4U" + 24" .. •- '-_{ 'I: ---' - '' -- - - -r ! • • , , .� l��■�� :R. N- Ot,i P-ANEL III 0£D DED 111 I \.-- .,::r % 1 ," ,'`�y{ *' _1 11 _ 1• Q ��� r-7r1■al • - R 4 oil_ �i � ... "rr�"-- '�-� ,'k _•, I B �r��r, ! Ii:�i i__ ___. II "` L--3 -._ ''s� '�; .1 I++ AK _,� r k1l i, _..._ rp -.lo___ n.� `c Q 1 =� -� *.2911111111Mini_11 ■■���� If + ,; 1113E ci; I ,0 29 -7111-1141-1 -�' �--a- r■�11�11■ :: W I 11 . 1 HALO 124 Il I II I 11111111111111111111. L-4 ® L r�11 - ■,�0 ' '�- --------` 46 '1� ` L TOIL = r'_%! ' `;: 12 4 j _ _ _ ■ Q ,,, � . A i i --. . - II - cr' I. 112 - -- IT-"< 4._ ..______________J_ VIIIw `ef AIL k 1111®■1.E■■ • II N- -ii__ ___..1 WEI Eak , � �: _ ,,a r , ... .1 ., ���- � �< ULTRA L � >�E.o'�2�-7 -k------- T-7771:ffi A 112-5 � � J ��■ ► ® I --- - 114E _ SSD w ._ L MED ry R „ kti 0 ,, , : z- __. 6 - {i -.. ('i,LL I I# t i I �-, fi._..'�? (V-1-4 1 I'} a+:zww+rx*+.s: �rt.�*i...�.M:N�!.'. {. C i+ 11 �ca �I- 111 1 �� I - { j { ; i la.ci- i. t1 --;'• �r Ii + :1fa- MI5 MB I it 4. ��L41-1 i I � 1 -- ITL40 ��►. � 1; HALL � 1•�-; r ._ "466 ' - f �I I -� - r - i ; 1 i w j�._ -- i1 . . J 1�? oho ; _ -► L _� ,D 1I•.1�1•Clr� , , .1 0, ° ;,�• © �; -3 11i. 18 3 IT it �I__ - ,-: HALL S �E� �u_ l . II pi 17 1 I �� _. . ,_ , ._ k u �: # 118 I ill '. ruri4 I �' j j I 119 ��I r, !i L ! !1 I I ■_■■I ' ',u,k' i ++ i 1 a - 20 1> osco , I. ;I I; L_R • I` I I I L_ J -, ANDROL !i i ■° I r i 1 i 1 �. rir �D I. II �I II i \ UL� ' I 128 I I 'i ! iI■ it itII 11 I4 III II !iiii 1■.■,1111■■ I, OFFICE 1 1II jE ' I I�� 120 i21 121 ., " I I' '' Il - L-5 111■11■■■ ;I ,;I 4 ;I - ■�� 1�>r■rrnr Mil i if - - __� - _ _--, -.-,-_- 1I _- I ' f'iZ ;, © L---= - .�� .�.�...� f �-i - -- - .,, I LEI{ t. - - - , ii- - I - - - � \\ Elk] �. r� 0 -- - - �� .___:._�._....:_-__ �_.__-_.._W.__��- __:. r.-__..__, .���i��-=-W�-_r��# mo_��_....W.�_ � - L I L J _. PROJECT AREA OF WORK � ���_��}-�.��--^� 4-�-��T PROJECT AREA OF WORK _ _ _ .____ _. -. i I 2 : REFLECTED CEILING PLAN FIRST FLOOR 1 ELECTRICAL AND COMMUNICATION PLAN FIRST FLOUR ilk A2.1 SCALE: 1/8" = 1'-0" \\TA2.1 SCALE: 1/8" - 1'-0" Mr OREGON GENERAL NOTES FOR REFLECTED CEILING PLAN: LIGHT FIXTURE LEGEND GENERAL NOTES FOR POWER PLAN: REPRODUCTIVE 1. PROVIDE AND INSTALL NEW HEAVY DUTY SUSPENDED CEILING GRID AND TILES AS SHOWN. RECESSED 2'X2' 1. INSTALL ALL ELECTRICAL AND DATA DEVICES AT 18"AFF TO CENTER LINE OF BACK BOX UNLESS NOTED OTHERWISE. MEDICINE NOTE INDIVIDUAL CEILINGS IN ALL ENCLOSED ROOMS. ALL INTERIOR PARTITIONS EXTEND ABOVE L-1 MANUFACTUREER: LITHONIA CEILING. CENTER GRID IN EACH ROOM UNLESS NOTED OTHERWISE. FINISHED CEILING HEIGHT TO BE 9'-0" AFF EXCEPT HEADERS AS SHOWN WHICH ARE TO BE AT 7'-2" AFF AND LIGHT COVE STYLE: AVRNTE, 2AVL2 LED. RECESSED 2' X 2' FIXTURE. 2. PROVIDE GROUND FAULT DEVICES AND RESET BUTTONS AS REQUIRED BY CODE. SUITE 101 AT WAITING. PROVIDE DIMMING CONTROL. 3. PROVIDE A DEDICATED CIRCUIT WHERE "DED" IS SHOWN. VERIFY QTY. REQ'D. IN IT CABINET WITH TENANT'S I.T, VENDOR. 2. PROVIDE LIGHT FIXTURES AS SHOWN AND SCHEDULED. PROVIDE INDIVIDUAL CONTROLS FOR VERIFY IF BREAK REFRIGERATOR AND UC REFRIG AND FREEZER IN ANDROLOGY REQUIRES DEDICATED CIRCUIT ALSO. TIGARD, OREGON EACH FIXTURE TYPE, PER ROOM AND PROVIDE DIMMER CONTROLS FOR ALL. / L-1 FIXTURE ON BUILDING 24 HOUR EMERGENCY CIRCUIT, ELECTRICAL SUBCONTRACTOR TO CONFIRM QUANTITY SHOWN MEETS THE ELECTRICAL 4. REFER TO ELEVATIONS FOR ADDITIONAL INFORMATION TO COORDINATE ELECTRICAL DEVICES WITI-I CASEWORK AND 3. ALL EMERGENCY LIGHTING, SPRINKLERS, SMOKE DETECTORS, FIRE ALARM, COMMUNICATION CODE AND REVISE IF NECESSARY. EQUIPMENT. DEVICES AND ALL OTHER REQUIREMENTS TO CONFORM TO OREGON STATE BUILDING AND LIFE SAFETY CODES AND ARE TO BE DESIGN BUILD AND THE RESPONSIBILITY OF THE GENERAL ® EXIT SIGN 5. INSTALL SWITCHES AT 48"AFF AND THERMOSTAT AT 48" AFF, UNLESS NOTED OTHERWISE. Drawing Title CONTRACTOR. PROVIDE DEVICES AS NECESSARY. DIMENSIONS ARE TO THE CENTER LINE OF THE BOX. 4. GENERAL CONTRACTOR TO PROVIDE DESIGN BUILD HVAC AS REQUIRED, COORDINATE AND . AUDIBLE/VISUAL ALARM, SUBCONTRACTOR TO VERIFY QTY REVD. 6. COORDINATE TENANT PROVIDED VOICE AND DATA WIRING & SECURITY WITH AZIMUTH FOR CABLING AND CENTERLOGIC. POWER AND REVIEW WITH THE BUILDING ENGINEER AND BUILDING OWNER. 6-7 INDIVIDUAL ZONES REQUIRED, CONTACT CAREY TOMBERG, FACILITY MANAGER 0 ORM FOR NAME AND NUMBER. COMMUNICATION PLAN, PROVIDE BALANCING AT THE END OF THE PROJECT. - -- - L-2 - LITHONIA LIGHTING, UCLD LED LINKABLE CABINET LIGHT, COLOR WHITE, HARD REFLECTED CEILING WIRE FIXTURES. TOGGLE SWITCH, REFER TO ELEVATIONS FOR ADDITIONAL 7. ALL ELECTRICAL DEVICES AND COVERPLATES TO BE STAINLESS STEEL 5. INSTALL SWITCHES AT 48"AFF AND THERMOSTAT AT 48" AFF, UNLESS NOTED OTHERWISE. INFORMATION. SWITCH SEPARATE FROM CEILING FIXTURE. MOUNT AT FRONT OF DIMENSIONS ARE TO THE CENTER LINE OF THE BOX. UPPER CABINET FACING BACK WALL. 8. OFFSET ALL BACK TO BACK DEVICES TO MINIMIZE SOUND TRANSMISSION. SEAL AROUND EACH PLAN DEVICE. 6. UNTRASOUND ROOMS 116, 118, AND 121 TO HAVE INDEPENDENT HVAC CONTROL, VERIFY O L-3 - RECESSED CAN LIGHT FIXTURE: INDY, L6, 6" LED, NEW CONSTRUCTION, WHITE FLANGE, COOLING REQUIREMENTS WITH TENANT. PROVIDE DIMMING CONTROL. 9. GENERAL CONTRACTOR TO COORDINATE AND CONFIRM POWER REQUIREMENTS FOR TENANT PROVIDED EQUIPMENT. 7. PROVIDE SOUND BOOTS AT ALL RETURN AIR GRILLS THAT FACE AWAY FROM ADJACENT - RECESSED CAN LIGHT FIXTURE ON EMERGENCY CIRCUIT 10. GENERALOCONTRACTOR TO PROVIDE ROUGH IN AND PULL STRINGS FOR ALL DATA, COMMUNICATION AND SECURITY OCCUPIED SPACES IF NON-DUCTED RETURN. �� k:P: 8. CENTER CEILING MOUNTED LIGHTS IN 2 X 2 SECTION OF SCORED 2 X 4 CEILING PANELS. f I L-4 - VANITY LIGHT FIXTURE: POSSINI EURO UNITY VANITY LIGHT #EU2T793, 28", BRUSHED NICKEL, 11. PROVIDE ALL REQUIRED WORK FOR THE TENANT AREA SHOWN, INCLUDING ALL WORK RELATED TO MECHANICAL AND v LED, INSTALL CENTERED ABOVE MIRROR, REFER TO ELEVATIONS FOR MORE INFORMATION. PLUMBING. WORK TO MEET ALL CURRENT ELECTRICAL CODES. � Ka� enberg 9. REFER TO A8.3 FOR CEILING DETAILS. 0, ELECTRICAL AND COMMUNICATION PLAN NOTES: n L-5 - WALL SCONCE: MATCH FIXTURE USED AT TENANT'S 808 BUILDING ULTRASOUND ROOMS. tt. ORTLANI), OREGON ;.� on 0INSTALL AT 84"H. AFF TO BOTTOM OF FIXTURE., PROVIDE DIMMING CONTROL PROVIDE PLUG MOLD THIS ROOM FOR MICROSCOPE AND OTHER EQUIPMENT INSTALL ABOVE BACKSPLASH NORTH & WEST WALLS. REFLECTED CEILING PLAN NOTES: O PROVIDE POWER RECEPTACLE MINIMUM OF EVERY 18" O.C. a) . ■ I• +• . ■ • L-6 -- CONTINUOUS COVE LIGHTING IN CEILING OF WAITING OVER RECEPTION DESK: O,F 4 CENTER RECESSED CAN LIGHT IN ROOM. LITHONIA LIGHTING, CLX LINEAR, LED, ROUND LENSE. DETERMINE NUMBER OF FIXTURES . PROVIDE A FLOOR FEED TO SUPPLY POWER AND DATA TO MA DESK. O AND LENGTHS REQUIRED TO LIGHT THE ENTIRE CURVED COVE, LINK FIXTURES TOGETHER COORDINATE WITH CASEWORK DRAWINGS .0_ AND PROVIDE A DIMMING CONTROL.Cn -0Q 0 GYPSUM BOARD CEILING THIS ROOM FINISHED HEIGHT 9'-0", PAINT P-1 © COORDINATE WITH PLUMBING SUB-CONTRACTOR FOR POWER REQUIRED FOR HOT WATER HEATER. I PROVIDE ACCESS PANELS AS REQUIRED. L-7 -- WALL WASHING FIXTURE FOR SIGNAGE - CENTER ON WOOD FEATURE WALL : I I " Date: APRIL 23,2018 rx Li •O PROVIDE SPEAKERS FOR TENANT'S SOUND SYSTEM COORDINATE WITH VENDOR MARK ARCHITECTUAL, SLOT 4 LED, 4 X 4)-0"W, TG CEILING TRIM, O PROVIDE POWER FOR ACCENT LIGHTING AT RECEPTION DESK, COORDINATE FEED LOCATION WITH CASEWORK. o E PROVIDE DIMMING CONTROL. LED, TAPE TYPE FIXTURE. Job No: P24144.01 a OPROVIDE CEILING TRACK UNDER GYP HEADER AT ROOM OPENING FOR PRIVACY CURTAIN. L-8 - "VOLT" LINEAR LED STRIP LIGHT UNDER RECEPTION AND CHECK OUT LEDGES TO WASH FACE © PROVIDE POWER AND CONNECTIONS TO TENANT PROVIDED TV MONITOR Drawn By: JAN ECKELMAN �I OF WOOD DIE WALL. VERIFY AND MATCH FIXTURE USED AT TENANT'S 808 BUILDING v 0--0 © 5"W. CURVED RECESSED COVE FOR LIGHTING, REFER TO 11/A8.3 PROVIDE DIMMING CONTROL INSIDE RECEPTION AREA O CARD READER LOCK AT THIS DOOR. Checked By: CLAUDIASTYRSKY - E o -6 o O CONTROL FOR ALL HALLWAY LIGHTING NEAR STAFF ENTRY DOOR. S LIGHT SWITCH O ELECTRICAL PANELS IN WALL. PAINT TO MATCH ADJACENT SURFACE. C• Q Drawing No. `r' 1 CONTROL FOR L-3 & L-6 IN HALL 122, CONTROL FOR L-8 IN RECEPTION 101 m VOICE/DATA WIRING SYMBOLS 0 E 0, O CONTROLS FOR L-1, L-7 AND L-8 IN RECEPTION 101 ¶ VOICE AND DATA, TENANT VENDOR TO CONFIRM QTY OF CABLES REQUIRED d' 0 N O PROVIDE AN EXHAUST FAN, QUIET FOR BREAK ROOM AND JANITOR/U11LIY AND LOUD DUPLEX OUTLET ' FAN AT TOILET ROOMS, SWITCH/CONTROL BY OCCUPANCY SENSORS. 4-PLEX OUTLETA2 i 1 E. CL Li-)x` T7ED DEDICATED OUTLET fm � o JO JUNCTION BOX Ai 6 PERMIT SET 6a icti I Ir%L, I 11-1\71 I I I /11 ,..t♦ TOWEL DISPENSER SEMI-RECESSED SINK/FAUCET:KOHLER ODEON SEMI-RECESSED PAPER TOWEL DISP LIGHT FIXTURE WITH ZG FI 22" DEEP PLASTIC LAVATORY K-11160-1 PAPER TOWEL DISP RECEPTACLE TRASH 4'-6" LAMINATE COUNTER SINGLE HOLE, WITH QT-1 WITH TRASH BELOW ON SIDE WALL SINK/FAUCET:KOHLER ODEON SEMI-RECESSED 3 EQ WITH SELF EDGE COUNTER AND SIDE RECEPTACLE BELOW PAPER TOWEL DISP " LAVATORY K-11160-1 " WITH TRASH " SURROUNDS, 4"H QT-1 ON SIDE WALL, SEE SINGLE HOLE WITH QT-1 ! \ \ WALL SINK/FAUCET:ELKAY LR1316 13 X BACKSPLASH. COORDINATE FLOOR PLAN FOR E EPT CLE BELOW ZIMMER GUNSUL FRASCA ARCHITECTS LLP LIGHT FIXTURE COUNTER AND SIDE _ - '- -\-- - w 16" COORDINATE WITH FAUCET SS SPECIMEN SHELF IN WITH FAUCET AQUABRASS LOCATIONS SURROUNDS, 4"H QT-1 Co / - • �� AQUABRASS #61044BN, CHOWN 601044BN, CHOWN 142169. " r ) w ROOMS PER ACCESSORY WC-10 . EP-2ILBACKSPLASH. COORDINATE 2-3 T-1 QUARTZ J/ G�OVES ►- 142169, FlNISH: SATIN NICKEL, SCHEDULE WITH FAUCET AQUABRASS 1 FRONT AND SIDE PORTLAND -X- _, DISP _ W PROJECTION 4.375" MIRROR PROVIDED BY TENANT, \ ! Ito v t 3'-6" 6010446N, CHOWN 142169. PANELS, SEATTLE ID CONTRACTOR INSTALLED COUNTER, BACK v r= >_ - - -� ^ INSTALL TENANTS FOLD DOWN LOS ANGELES 4 ce TV MONITOR W/POWER AND CABLE BEHIND AND SIDE SPLASH I _ 1 A; .� MI �' DC \SHARPS- OPENING FOR TRASH WITH ONE TOILET: COMPACT, �, _ .\ --=---� I - MIRROR PROVIDED BY TENANT \ a NEW YORK — DISPENSER ELONGATED, ADA TANK t o '� _ LOWER ADJUSTABLE SHELF. ® _cit,. ''r 'y x = 1 n N = lown _ f x = � „� �. .�. � �, CONTRACTOR INSTALLED NO MORE = w � ¢ .4. �- -" - TOILET, KOHLER SANTA 2'_1O" 1 „i -�'- „I j 2'-10" i THAN 40"AFF TO REFLECTIVE d- a m .I ri iv - DRAWERS WITH FULL ROSA, PROVIDE A SOFT , ,� _ w �� M w 'n SURFACE N �- ce 'r' LAI _ ~' CLOSE LID. I h , `� cr N 111111 �� EXTENSION GLIDES, TYP. =• -^I�: 0 '-6 .I TOILET: COMPACT, ELONGATED, • • n• • o }1'-61'-3" WEST / ' WEST ADA TANK TOILET, KOHLER ALL DRAWER AND DOOR PULLS TO BE SANTA ROSA, PROVIDE A SOFT SOUTH S.S. SHELF 6" LADDER STYLE SS PULLS TO MATCH CLOSE LID. C PULLS AT 808 BUILDING, TYP. 2 TOLL ROOM 112 ( 129 AND 119 SIMILAR) 1 COLLECTION ROOM 3 ULTRA SOUND 116, 118, 121 A7.0 SCALE: 1/4" = 1'-0" A7.0 SCALE: 1/4" = 1'-0" A7.0 SCALE: 1/4" = 1'-0" Revisions SINK/FAUCET:ELKAY r- HALF HEIGHT PAPER LUSTERTONE 18GA / 7'-8" TOWEL DISPENSER STAINLESS STEEL, 22" XLVERIFY 6'-O" (2 EQ.) 3'_3" (2)EQ. CABINETS 25"W X 10"D. COORDINATE tt .� 1' �2._0"f 12"D UPPER • .,.` WITH FAUCET CHICAGO \ ,,, A A ,,\ -\-- /. ,� ABINET W/ONE . 7 \ #"186-E3ABCP, 8 SPOUT _Z_ _` _L `�_ _ _Z _--\-- PROVIDE AND INSTALL METAL / / '`"-- _:� REACHTENANT'S _ _ _�, _ _ CONTINUOUS WIREMOLD OPEN SHELF. d- _ / \ / \ -- - " X > ABOVE SPLASH / WALL BRACKET T i �_ -- _7 `I- HANGING STORAGE BINS. -\,- _ - - / - -- - j " TENANT PROVIDED �. i WINDOW WINDOW _ \ / \ / r -- _\; _ ;/ MATCH TENANT'S EXISTING. �' �,}/ \U' ~' DUTCH STYLE DOOR. PROVIDE _ / 6-PACK SIZE MINI OPEN OPEN ? HARDWARE TO ALLOW TOP AND �' REFRIG. WEN Al TB-1 FABRIC WRAPPED \ / \4I- / i 1 BOTTOM SECTIONS TO BE SECURED r_ ��__ \ TACK PANELS \ I co , _ —_— �'_ 1 ,,,_,,,, ' ' CONTINUOUS WIREMOLD 1 ,. '� TOGETHER FROM INSIDE RM. 128. oo HALF HT PAPER 6¢aati I— L—— -1 KJI 3 r I I ! 1 4= •.-_,.,,,,..,_ `-nr, rtll��I _ .- t . E_ _ _1 t_ _�_,__ ABOVE SPLASH _- I DOOR TO HAVE CLASSROOM r TOWEL DISPENSER 46 TNI " - ;- --ri.- ---Ir - - - - FUNCTION LOCK. PROVIDE A WALL 1_, •-NI I am \- 2'-0 0 2'-0" 2'-0 = 2'-0" _ 2 -0 � I It - `N. STOP FOR BOTH HALVES. b 1t MO 12" SS SINK WITH I < . I ® ' c1.; ® 2 L : I NEE EI [L E 4 f -- T �` . C? , I l� i t C� .� CHICAGO M ,,\ .."y-L � / OPEN e� pi • ADJUSTABLE HEIGHT c : REFR ii RIR - 7. IN N 786-E3ABCP \ I ` SHELVES, VERIFY WIDTH OF ,I ,,,'' - ��e"`�m FAUCET. 4'-6 4'-2" 1'�-�G� 5'-0" 3'-6" 6 EXISTING STORAGE BINS Al 4'-4" 6 �' OPENING FOR TRASH WITH SOUTH WEST - 808 SO 2 FIT ON EACH. NORTH ' U.C.REFR SIZE: 24"W X 25" X AST ONE LOWER ADJUSTABLE 2 EQ, VERIFY VERIFY 34_5/8"H WEST SHELF, U.C.FREEZER SIZE: 24" X 25" X 5 ANDROLOGY 128 34-5/8"H 4 LACTATION 125 A7.0 SCALE: 1/4" = 1'-0" PRIVACY CURTAIN AND HALF HEIGHT PAPER A7.0 SCALE: 1/4" = 1'-0" SINK/FAUCET: ELKAY 18GA TOWEL DISPENSER STAINLESS STEEL LRAD 1922, 24"D, ALL EAST CABINETS TRACK MNT'D UNDER 6.5"D. TO MEET ADA. COORDINATE OPENING TO 10'-0" WITH FAUCET HANSGROHE, TAUS Si MIDDLE CABINET TO PHLEBOTOMY STAINLESS STEEL WITH DECK MOUNTEDKEYE WASH " r " , " SPRAY, HIGH ARC KITCHEN -FAUCET, HAVE ADJ. SHELVES. SPEAKMAN SSE 927 3}-6" 3_O 3 EQ. 2-6 k 3 EQ. �,2-O , PULL DOWN, FINISH: CHROME 3 EQUAL CABINET / UNDER CABINET LIGHT EQ. DOOR #14872001, INCLUDE FILTERED TENANT'S I.T./TEL.E FIXTURE. r UNDER CABINET UGHT j WATER SYSTEM. EQUIPMENT TO BE / _1_ _ _ _! _ / / \ / \ / \ _ OPEN ABOVE HOUSED IN CLOSET. / \ ! \ - - \- SINK/FAUCET: ELKAY -7, - -�-` -`t- -t� / / \ / \ / \ � HAL.,F HEIGHT PAPER / FULL HEIGHT TILE - - - - - �- - " —" TOWEL DISPENSER ,� PROVIDE FIRE TREATED - - - - - - - - - - LUSTERTONE, 18GA _ a►" ° BACKSPLASH T-1 /\ / STAINLESS STEEL, 19" X 22", ;'` - -s---_ - -%� f i PLYWOOD BOARD ON �- I \ \ / -- _ \ / T-1 TILE BACKSPLASH WITH _ _ _`� / \ BACK WALL 4 X ?. \ ! \ \ / X 10"D. TO MEET ADA. ` �� ' " ` %� OREGON ' t _ 0 \ \ / ,� / / SS SCWLUEIER TRIM AT SIDES / -\ -� -�- / \ OPEN TOP FOR - - - - -- -- - COORDINATE 1MTH FAUCET -,�- - - - 20 D' COUNTER o r� :� r i r c. a // = ,. / _ - \ / \\ VENTILATION. oo [� T CHICAGO 7861 I; -E3ABPC, O0 a) C° a REPRODUCTIVE REMO ' 111 6 .. _I _I - - TENANT PROVIDED MICROWAVE 1 rr- I I ! \ I I (1) COAT CLOSET, \ fl ro SPOUT APPROX. 8" �� I : I : ...::.. .: W/LARGE DRAWER BELOW. r' I \ _ \ - / \ / HALF WIDTH TO NAVE au L 1 - �- - 4 �a • - w f� OPEN CABINET FOR = _ ' PROVIDE DOOR TO HIDE MEDICINE 11111 - °1 " �7 o MW:19"W X 13"D X 10.5"H in \ / STANDARD HEIGHT ROD o , I I OPEN r--Td I , d o t N .'I MED ,► N E tY I r''�T I N r I r I \ ""/" " o o REFIGERATOR, MOLD TOP OF DOOR CI w 1 _ < x _ I - - • \ 74 4. 4. , / AND ONE HALF ADA „I > Qo I p/� 18"W X 19 D X 19.5"H I I • - m� 1" FROM UNDERSIDE OF COUNTER ,� _ ,, ' WEIGHT ROD AND "� ' / '. REFRIG. AND PRINTER \\*in / '� ' .I. N PROVIDE A WATER FILTER \/ �� SHELF, FULL WIDTH 14"W X 10"D X $.8"W TOP FOR AIR CIRCULATION. NO SUITE ' 3 EQ. 2-6' AND A COLD WATER UNE TO ` `` 4,_O" SHELF 5'-4"H, `2'-0" �2'-0" ON ONE HEAVY DUTY ta���r.:>>trrr�r� BASE. " " NORTH CLR 2'-0" TENANT'S COFFEE BREWER. EAST (2) EQUAL CAB'S VERIFY ,i, 3'_O" VERIFY PULL OUT SHELF. WEST EQUIPMENT N.I.C. SOUTH REFRIG SIZE: 24"W X 25"D X TIGARD,OREGON PROVIDE LOUVER VENTS EAST 34-5/8"H WHEN OPEN BASE WITH TE KICK IN BOTTOM OF DOORS OPEN ATTACHED TO DOORS FOR FOR AIR FLOW TO ADA ACCESSIBILITY EQUIP. 6 HALLWAY 114 8 BREAK ROOM 7 PHLEBOTOMY 103 A7.0 SCALE: 1/4" = 1'-0" Drawing Title A7.0 SCALE: 1/4" = 1'-0" A7.0 SCALE: 1/4" = 1'-0" INTERIOR ELEVATIONS VERIFY I, EQ. EQ. y ACCESSORY SCHEDULE 1 PROVIDE WALL MOUNTED OPEN, ADJ. SHELVING SINK/FAUCET: ELKAY MOP RACK. LUSTERTONE, 18GA III ', STAINLESS STEEL, 19" X 22", � ALF HEIGHT PAPER �� PROVIDE WALL MOUNTED �— X 10"D. TO MEET ADA. - � TOWEL DISPENSER12 D X ADJ. SHELVES ON �� COORDINATE WITH FAUCET HEAVY DUTY BRACKETS AND illridEM5x20 CHICAGO 786-E3ABPC, _1 STANDARDS — SPOUT APPROX. 8" ---- o _ AUTO-CLAVE �■ 1 ,� co r I I 1 SERVICE SINK. tttPlir� ,OUR ■-' ONE OPEN, ADJUSTABLE _ wNt � FAUCET: CHICAGO #897 CP -� � SHELF FOR AC TRAY a °CS>o � I I , I WALL PROTECT PANELS ON I _ Y � � - - STORAGEi� p `. , BOTH NORTH AND EAST •. ., 2335 r Nor VERIFY SIZE AND SPACE ■ ,,,,,,P„��� WALLS. ACCESSORY SCHEDULE ' `$ SOUTH 2'-°" di REQUIRED FOR HOT NORTH - WATER HEATER. ACCESSORIES MANUFACTURER PRODUCT NAME/N0. FINISHES/'COLOR REMARKS • ` ORTLANO, OREGON . SPECIMEN PASS THROUGH BOBRICK B--505 SATIN STAINLESS STEEL HALL0127CTION 126 TO r {{,, 9 JANITOR/UTILITY 115 TOILET ROOM 112, 119 AND '" OF d\ky �, A7.0 SCALE: 1/4" = 1'-O" SHELF - 16" LONG BOBRICK B-295-16, 16" LONG SATIN STAINLESS STEEL COLLECTION 126 (VERIFY W/ORM) 03 CASEWORK NOTES: ' AT ULTRASOUNDS, PHLEBOTOMY 1 PAPER TOWEL DISPENSER BOBRICK B-2621 HALF-HEIGHT SATIN STAINLESS STEEL LAC, JAN UTIL, BREAK, ANDROLOGY SEE ELEV. / PLANS 1. ALL ARCHITECTURAL CABINET CONSTRUCTION SHALL MEET OR EXCEED ARCHITECTURAL WOODWORK SEMI-RECESSED PAPER TOWEL i E . UNITS WHERE POSSI E1" STANDARDS, 1ST EDITION - 2009, CUSTOM GRADE QUALITY WHERE PLASTIC LAMINATE. . DISPENSER AND TRASH RECEPT BOBRICK B--3942 SATIN STAINLESS STEEL AT TOILET ROOMS AND COLLECTION SHELF HOLES Date: APRIL 23,2018 ct O.C. VERT. FOR 2 EACH IN ULTRASOUNDS, TOILETS, o WORK SURFACE BRACKET ROBE HOOK BOBRICK B-7'6717 SATIN STAINLESS STEEL /\ /\ SHELF SUPPORTS RAFFLE 287.74.304 2. SE INTERIOR ELEVATIONS FOR ACTUAL ARRANGEMENT OF CASEWORK AND SPECIFIC DIMENSIONS. PHLEB., LAC AND COLLECT. 4 IN Job No: P24144.01 -!- -'' - "/- -\- -f - -\ ADJ. SHELVES PAINTED ATO MATCH TEAM 104 St 110, 2 IN OFFICES. CD 3. CASEWORK TO BE FLUSH OVERLAY CONSTRUCTION, MELAMINE CABINET INTERIORS, WITH PLASTIC WHERE THERE ARE 2, STAGGER 12" 1 l - - -Y - -V- - - " CLE SIDE ADJACENT WALL PAINT " " Drawn By .IAN ECKELI LAN t r, n DOOR WITH 6 APART '�� 48 H & 64 H I LAMINATE EXPOSED SURFACES AND EDGES. WHERE CABINETS ARE OPEN/EXPOSED, INTERIOR 0 \ / \ /. \ // S.S. LADDER INSTALL TENANT-PROVIDED MIRROR checked CLAUDIA STYRSKY '''-° / PLASTIC LAMINATE FINISH TO MATCH EXTERIOR FINISH MIRROR STYLE PULLS 112, 119, 125, 126 AND 129) cp-�i, P.LAM. 25" 4. CONTRACTOR TO FIELD INSTALL 3" GROMMETS WITHIN COUNTER TOPS WHERE ALL POWER/DATA SURFACE MOUNTED BOBRICK B-270 SATIN STAINLESS STEEL AT TOILET ROOMS 4) v BACKSPLASH OUTLET GROUPINGS OR PLUMBING OCCURS BELOW. FIELD VERIFY LOCATIONS AND COLOR WITH SANITARY NAPKIN DISPOSAL U.N.O. Drawing No. rn o r� - - �n 1" r- TENANT AND ARCHITECT. TOILET PAPER DISPENSER BOBRICK B--4288 SATIN STAINLESS STEEL ALL TOILET ROOMS, COLLECT E m _ _ X ; DRAWER WITH 6" 5. CONTRACTOR TO COORDINATE ALL PLUMBING, FIXTURE AND APPLIANCE REQUIREMENTS PRIOR TO TOILET SEAT COVER DISPENSER BOBRICK 8--221 SATIN STAINLESS STEEL AT TOILET ROOMS, COLLECT \ / / S.S. LADDER STYLE ANY CASEWORK FABRICATION. - „ PULLS "" �,; BABY CHANGING STATION KOALA MATCH 808 BLDG - AT TOILET 129 -a ,.to ADJUSTABLE 6. LETTER FILE CAPACITY Al ALL FILE DRAWERS, FILE FRONT TO BACK. PROVIDE PENDAFLEX OR i"' SEE ELEV. / PLANS SHELVES MOP RACK BOBRICK 6--223 STAINLESS STEEL AT JAN/UTILITY 115 4, 6', EQ. UNITS WHERE POSSIB' • SCHEDULED BASE NOTE: * SEE ELEVATIONS FOR DIMENSIONS SIMILAR SYSTEM IN FILE DRAWERSA7 . 0 a 7. UPPER CABINETS TO BE 1'-0" D CLEAR INTERIOR. U.N.O. ADA GRAB BARS AT TOILETS PER PLAN AND GENERAL FLOOR PLAN NOTES a 0 10 TYPICAL P.LAM. CASEWORK A.W.I. CUSTOM RADE 8. INTERIOR MELAMINE COLOR AT NEW CASEWORK IS TO BE WHITE, TYPICAL EXTERIOR PLASTIC SOAP DISPENSERS OWNER FURNISHED A7.0 SCALE: 1/4 = r-0" LAMINATE COLOR INDICATED IN FINISH SCHEDULE.Ai ii iii PERMIT SET : b i6 9. RADIUS ALL EXPOSED OUTSIDE COUNTER TOP CORNERS, 1-1/2" RADIUS. i.Lax CHECK IN " " RADIUS , " ZO F 8 11 3_6 ,2-0 , 19'-O" 4%--2" , ZIMMER GUNSUL FRASCA ARCHITECTS UP A8.3 A8.3 / 1 r-* RADIUS CURVED, RECESSEDi.::- ; I --*- ;� 14'-3" r LIGHT COVE BEYOND 4 _r *! PORTLAND f` I I N SEATTLE GELES �— • �� STAINLESS STEEL ON CURVED LIGHT 2'-O" WASHINGTON DC • 7 OPENI VALENCE (STRAIGHT AT CHK-OUT) ( 7 / / (- - NEW YORK A8.2 a A8.2 IN 8 3 CM THICK QT-1 QUARTZ TRANSAC11ON A8.2 OPEN �� <* ROECEP i ,r TOfi AND WORK SURFACE �` • .____�_ , " / "r• --"-- --a®.. 1 5 21-0 i:, CHECK OUT WOOD , ,{" / <° '/r,'r!'//,'/r,'//,'/r/t Mfr/,'/�//o/ b 'i r,'r;i;'i�,'r r,'i f,'i r,'i�,'r f,'i r,'r r,'i+r'i a'/r,tr,,rr,,rr,1r` ig A8.2 " ---—, 1'- PANEL �-% I `rli`/!`/rr`/'r`/'rr/tr`/fr`rrr`/rr`/'r`/1 CURVED DIE WALL WITH WOOD VENEER rrjj'trflrj'Jj,'r/r'tf,'rr,'ir,'ij,'tr,'rr,'tr!'r�`rj,'r1,'rj,'ir,'l -I 4 SOLID OAK BASE, �' , " • '/`�'r 0`r',`r'/`�'r`r't 00////-0', STRAIGHT DIE WALL WITH WOOD VENEER r t/ rt r,�!/,�rt,�rt j�rr/�!/,�/t,,'t,,rt.0., /�rr,�rr j�rr// /, , STAINED TO MATCH _F,.., :,,,,,,,,,,I 1 i`_;r • ' ` BOTH TO MATCH ORM 808 BLDG VENEER ` ` DOORS 1,-0" {� EAST CHECK OUT / SOUTH CHECK IN Revisions 3 EXTERIOR RECEPTION DESK FROM HALL 122 2 EXTERIOR RECEPTION DESK FROM WAITING 100 1 ENLARGED PLAN - RECEPTION DESK A7.1 SCALE: 1/4" = 1'-0" A7.1 SCALE: 1/4" = 1'-0" A7.1 SCALE: 1/4" = 1'-0" QUARTZ ON 36"H 1 PORTION OF COUNTER A8.2 7'-4" QUARTZ LEDGE, VERTICAL " CURVED QUARTZ COUNTER AND WRAP AND COUNTER 3 -6 (.1:.) LEDGE W/WATERFALL 5'-6" VERIFY f t SIDE t (4) EQ. DOORS t 12". .1' /12" I \ /' \ / \ '`''.'`'' ''`'`''`'`' PLAIN SUCED, SUP MATCHED UNDER CABINET ;-� - - �\- ' ` ' i'�/'°`'''`'�`'�l%`�,'i�''` NATURAL WALNUT WOOD VENEER PROVIDE COUNTER a- - -\- -I- - - � �r ,r ,t ,r ,r ,r ,r ,r r/r/// r/r/r/r/r/ __,,-. _ 4- LIGHTING. (' \) SUPPORTS AS , i \ / \� TB-1 WRAPPED �, �, i, rho,�, �, /, PANELING WITH STAINLESS STEEL NEEDED, PAINT TO '\ /x\ I PANEL. l;;;!l;;�,r;;`;/ ANGLE AT ALL SIDES ON TOP OF OPEN ii II, _ �- _ �- _\.._ _ _ j/r/r' //r/r///r' OPEN MATCH ADM WALL, \ / \ '0//`,00000//`, GYP. BD. WALL SURFACE. PROVIDE 3 _ �, CHECK OUT TB-1.WRAPPED If CHECK 1N TYPICAL. CHECK IN v \u P.LAM ON HIGH " ,/, i, / �, /, 0, /, /, ROWS OF HORIZONTAL Z-CUPS PER PORTION OF o ,l,l,l ,l,/,/,/,/ " I PANEL. ,.. w p OPEN CHECK OUT I :, & • , ;. I �/ ,r ,t ,r ,r ,r ,r ,r PANEL. MATCH 808 BLDG PANEL cv 2'-0" iv °° COUNTER 2'-0" //r/ r/ r/ r/r/r/r/ 4—A,-4 , ---- °' 2-0 �`//`//'l///�''�`l'//�`l - ORM LOGO/SIGNAGE IN WOOD PANELING, I) 1 :- MATCH QUARTZ / r / / r r / /'•4 �` ;,.., 44 OPEN Iv THICKNESS �` w ` f' r' r' '/ tf rJ '/ '/ _ ..., _ _ ,l,r,/,l,l,r,l,l BY OTHERS — I a io cD a .f ---SIpE WORK CO . <... r -I/ i\` `/jl�,l r,j/,/�l,rrl�/l�,l if, 4 ' I I 0 2' '--0" • - - SURFACE i 0I �I _-_-s OPENFOR17 00000000 ► 4" SOLID OAK BASE, STAINED - i+) '� '� i� ` SUPPORTED BY '`' i� ,) - -'" BASE " i� 0000V/000 A8.2 TO MATCH DOORS UNDER _ BASE CABINET IN Y t SHRED B1N:19 W ,i .., ,r././..._,,./_u_ - FOREGROUND � \ ` X 17"D X 35"H, ` \ � STAINLESS STEEL ANGLE WEST s'-6111111 , NORTH �'-4. 1'-3"1'-3"1'-10" BEHIND P.LAM. SOUTH DOOR1 4 RUBBER BASE A8.2 4 INTERIOR RECEPTION DESK A7.1 SCALE: 1/4" = 1'-0" Aga. OREGON 8 48'-10" ' ALIGN-- REPRODUCTIVE A8.3 A8.1 t VERIFYt 4'-4" ir 4'-0" /t 2, MEDICINE PAINT GYP HEADER PAINT GYP HEADER PAINT GYP HEADER '/I ii\ //r i\i // \ UNDER CABINET �/v �' �2'-0"� SUITE L!� OPEN i, , LIGHTING. _-''4 1- T(GARD,OREGON / \ / \ 7 <7 AA --''4 -4,. HALL 105 OPEN OPEN (1) PANEL OF TEMPERED, \i I ' n / \ I/ i l' Mk Wr f • GLASS, CHANNEL SET TOP t ti 7—TB-1 WRAPPED 2'-0" `Mk -OPEN " AND BOTTOM, GLASS TO I �` PANEL. f ' NVI � N '�`� HAVE POLISHED EDGES. I ,;' Tw /...."...L _ PL-1 1/8" PL-1 1 8" `r� .. `� _ PL-1 APPLY SOLYX FILM .. ,! ``' <t =-*c- Drawing-111e a a a / a � - - a \ - t ti (el I Cc REVEAL co " REVEAL co 'n = , I I I 0 I v �j PL-2 PL-2 OPEN OPEN 1 -0" PL-2 MPL-2 M •' `° -� I INTERIOR ELEVATIONS I I N. BOX/FILE/FILE DWR M I I ,N, �. , -. a PEDESTAL WITH \ \ = 1-41 v 1 EAST 2'-6" ji, SOUTH WEST-3`4.5" ONNSGING ID S FILE OF RAILS EAST EQ. 1'-3" EQ. 5 DRAWERS A8.1 8 EXTERIOR MA STATION 108 7 EXTERIOR MA STATION 108 6 ELEVATIONS - INTERIOR MA STATION 108 5 MA STATION 108 ENLARGED PLAN A7.1 SCALE 1/4" = 1'-0" A7.1 SCALE 1/4" = 1'-0" A7.1 SCALE 1/4" = 1'-0" A7.1 SCALE 1/4" = 1'-0" k,s, 233x r 1. 0.1' R. *;:it' oRTL AND,00.11011 'OF 00'LIL Date: APRIL 23,2018 M 0 Job No: P24144.01 Drawn By. JAN ECKELMAN Checked By: CLAUDIA STYRSKY g S ao �rnwI: da) 0 �, Drawing No. M c ECO ct 0 c, • Ooh N A7 ril 1 a• a0-a '- .4 CL'tI r..° PERMIT SET pW t%O.X I a) n a) U c ROOM FINISH SCHEDULE WITH CASEWORK DOOR SCHEDULE ZG F. „..._ I WALLS CASEWORK PANEL FRAME 0 1 NAME ROOM NAME FLOOR BASE NORTH EAST SOUTH WEST BASE COUNTER UPPER CEILING FINISH NOTES DOOR NO. TYPE WIDTH HEIGHT THICKNESS MATERIAL FINISH TYPE MATERIAL FINISH HARDWARE COMMENTS o 100 WAITING CPT WD-2 P-1 P-1 P-1 WC-13 WD-1/STAINLESS QT - ACT/P-1 REFER TO NOTE#15 100 B 3'-6" 7'-0" 1 314" WD CLR 1 TI ALUM FILM ON GLASS-WF ZIMMER GUNSUL FRASCA ARCHITECTS LIP I 101 RECEPTION CPT RB/WD-2 P-1 P-1 P-1/WD-1 P-1 WD-1/PL-2 QT/PL-1 PL--6 ACT 100A EXISTING KEYED LOCK SUITE ENTRY LOCK 4) - 102 OFFICE CPT RB P-1 P-2 P-1 WC - - - ACT 102 B 3'-0" 7'-0" 1 3/4" WD CLR 1 Ti ALUM FILM ON GLASS WF PORTLAND 1 103 PHLEBOTOMY LVT2 RB P-1 P-1 P-1 P-5 PL-4 PL-1 PL-3 ACT REFER TO NOTE#12 104 B 3'-0" 7'-0" 1 3/4" WD CLR 1 TI ALUM FILM ON GLASS-WF SEATTLE (0 104 TEAM 1 CPT RB P-1 P-2 P-1 P-2 ACT 106 B 3'-0" 7'-0" 1 3/4" WD CLR 2 TI ALUM FILM ON GLASS-WF LOS ANGELES 0 105 HALL CPT RB P-3 P-1 P-1 P-1 - - - ACT 107 B 3'-0" 7'-0" 13/4" WD CLR 2 TI ALUM FILM ON GLASS-WF WASHINGTON DC . NEW YORK 106 TEACH CPT RB P-1 P-1 P-1 WC-8 - - - ACT 109 B 3'-0" 7'-0" 1 3/4" WD CLR 2 TI ALUM FILM ON GLASS-WF 107 TEACH CPT RB P-1 P-1 P-1 WC-8 - - - ACT 110 B 3'-0" 7'-0" 1 3/4" WO CLR 2 TI ALUM FILM ON GLASS-WF 108 MA CPT RB P-1 P-1 P-1 P-1 PL-2 PL-I PL-6 ACT 112 A 3'-0" T-0" 13/4" WD CLR 1 TI ALUM PRIVACY LOCK COAT HOOKS/BACK OF DOOR (0 M 109 PHYSICIANS OFFICE WD-3 RB P-1 P-2 P-1 WC - - - ACT REFER TO NOTE#10 113 C 3'-0" 7'-0" 1 3/4" WD CLR TI ALUM a 110 TEAM 2 CPT RB P-2 P-2 P-1 P-1 ACT 114 EXISTING SDC 11190 SERIES CARD READER/CLOSER 111 HALL CPT RB P-1 P-1 P-1 P-3 PL-2/PL-1 PL-1 - ACT P.LAMS FOR DIE WALL FACE 115 C 3'-0" 7'-0" 1 3/4" WD CLR 1 TI ALUM CLOSER 112 TOILET LVT1 RB EP-1 EP-2 WC-10 EP-1 - QT - P-1 116 A 3'-0" 7'-0" 1 3/4" WD CLR 1 TI ALUM COAT HOOKS/BACK OF DOOR 113 BREAK ROOM LVT2 RB P-1/T-1 P-111-1 P-2 P-1 PL-2 PL-7 PL-2 ACT REFER TO NOTE#4 118 A 3'-0" 7'-0" 13/4" WD CLR I T1 ALUM COAT HOOKS/BACK OF DOOR Revisions 0. 114 HALL CPT RB P-3 P-3 P-3 - - - ACT REFER TO NOTE#4 119 A 3'-0" 7'-0" 1 3/4" WD CLR 1 TI ALUM PRIVACY LOCK COAT HOOKS/BACK OF DOOR Q 115 JANITOR/UTILITY LVT2 RB EP-IIWP-1 EP-1/WP-1 EP-1 EP-1 PL-2 PL-6 PL-3 ACT REFER TO NOTE#12 120 B 3'-0" 7'-0" 13/4" WD CLR 2 TI ALUM FILM ON GLASS-WF a • 116 ULTRASOUND LVT1 RB WC-6 P-2 P-1 P-1 PL-7 PL-5 PL-7 ACT 121 A 3'-0" 7'-0" 1 3/4" WD CLR 1 TI ALUM COAT HOOKS BACK OF DOOR 117 HALL CPT RB P-1 P-1 P-1 P-3 - - - ACT 123 NOT USED 118 ULTRASOUND LVT1 RB WC-6 P-2 P-1 P-1 PL-7 PL-5 PL-7 ACT 124 EXISTING SDC 11190 SERIES CARD READER/CLOSER 119 TOILET LVT1 RB WC-10 EP-1 EP-2 EP-1 - QT - P-1 125 A 3'-0" 7'-0" _ 1 3/4" WD CLR 1 TI ALUM PRIVACY LOCK COAT HOOKS/BACK OF DOOR 120 OFFICE CPT RB P-1 P-2 P-1 P-2 - - - ACT 126 A 3'-0" 7'-0" 1 3/4" WD CLR 1 TI ALUM PRIVACY LOCK I 121 ULTRASOUND LVT1 RB WC-6 P-2 P-1 P-1 PL-7 PL-5 PL-7 ACT 127 A 3'-0" 7'-0" 1 3/4" WD CLR 1 TI ALUM SDC 11190 SERIES CARD READER/CLOSER C 122 HALL CPT RB P-1 P-1 P-1 WC-13 WD-1/STAINLESS QT/PL-6 ACT 128 D 3'-0" 7'-0" 1 3/4" WD CLR 1 TI ALUM KEYED LOCK IVES DUTCH DOOR BOLT 0 N 123 NOT USED - - 129 A 3'-0" 7'-0" 1 3/4" WD CLR 1 TI ALUM PRIVACY LOCK COAT HOOKS/BACK OF DOOR 1 124 HALL CPT RB P-1 P-3 P-1 P-1 - - - ACT P4 BEHIND DOOR#127 •5 125 LACTATION LVT2 RB P-1 P-1 P4 P-1 PL-5 PL-3 PL-5 ACT DOOR AND DOOR FRAME NOTES ISCHEDUll, +.0 ED L- .CHEDUL- 0' 126 COLLECTION LVT2 RB EP-1 WC-2 EP-2 _EP-1 QT - ACT11F 4 ,44" 127 HALL CPT RB P-1 P-3 P-1 P-1 ACT 1. COORDINATE KEYING WITH TENANT AND BUILDING OWNER I yA, /1'-6"y 0 /ti. 128 ANDROLOGY LVT2 RB P-5 P-5 P-5 P-5 PL-4 PL-1 PL-3 ACT `� MIN. 1 129 TOILET LVT1 RB EP-1 EP-1 WC-10 EP-2 - QT - P-1 2 ALL TENANT DOOR FINISH TO BE RIFT CUT SELECT WHITE OAK, MFG.VT INDUSTRIES,STAIN: Lu -----5 RIVERSTONE RI15. INTERIOR DOOR FRAMES TO BE / W Ca o DOOR NUMBER FINISH SCHEDULE NOTES TIMELY IN ALUMITONE FINISH. _ // x v \ -L �— , 0 3. OTHER DOORS TO RECEIVE BUILDING STANDARD 0 \\ v' "' 1111 ` 1'-0" / / a 1. INSTALL ALL MATERIALS IN ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS, INCLUDING HARDWARE TYPE. PROVIDE CLOSERS AS REQUIRED BY CODE \ MIN. "' FOLLOWING INSTRUCTION FOR THE PREPARATION OF THE SUB-SURFACES MATERIALS ARE APPLIED TOO: AND AT DOORS WITH TRILOGY OR CARD READERS. VERIFY \ rn SOUND GASKETING IS PROVIDED AT ALL DOOR FRAMES. \ . TYPICAL DOOR 2. PROVIDE TO THE ARCHITECT SUBMITTAL SAMPLES AND PRODUCT INFORMATION FOR ALL FINISH MATERIALS 4. PROVIDE 14"H.SATIN STAINLESS STEEL KICK PLATES ON A E C I FOR REVIEW AND APPROVAL PRIOR TO ORDERING. • BOTH SIDES OF DOORS: 100, 115 AND 124. 6 3. PROVIDE 4'H CORNER GUARDS AT ALL EXPOSED CORNERS THROUGHOUT THE CLINIC,BOTTOM OF CORNER 5.TOP LEAF OF DUTCH DOOR TO RECEIVE: IVES#054 DUTCH , CHEDU .CHEDUL- • .“i 1 GUARD TO ALIGN WITH THE TOP OF WALL BASE. DOOR BOLT ON ANDROLOGY SIDE OF DOOR.KEYED LOCK ON i� 2” 2" �., 2" 2" 3'�" 2" LOWER PORTION. GLASS . — ." 4. T-1 FULL HEIGHT BACKSPLASH AT BREAK ROOM COUNTER AND ABOVE COUNTER IN HALL 114,REFER TO 1 ELEVATION. PROVIDE SCHLUTER METAL TRIM AT EXPOSED EDGES IN ALUMINUM SATIN ANODIZED FINISH. 6. PROVIDE ELECTRIFIED DOOR FRAMES ON DOORS WITH TR GNSCATION % OREGON ELECTRIC CARD READER. COORDINATE WITH BUILDING or, LEDGE UJ REPRODUCTIVE c'i" 5. ALL GYP. BD. SOFFITS TO BE PAINTED P-1. OWNER AT EXISTING WEST STAIR DOOR AND HALL 124. S o=1 w © 4 ,r MEDICINE 6. ALL HOLLOW METAL FRAMES AT 100A AND 124 TO BE PAINTED P-1 IN SEMI GLOSS, 7. PROVIDE WALL STOPS AT ALL DOORS, IVES#WS407CCV OR �'" al ACRINAMEL OR SIMILAR FINISH ON TENANT SIDE. PAINT CORRIDOR SIDE OF DOOR FRAMES DOMED FLOOR STOP#FS436 \ DOOR BOLT 0„ ,f til U ITE 101 TO MATCH BUILDING STANDARD COLOR. co N \ \ zek, TIGARD,OREGON a. 7. PROVIDE SCHLUTER RENO SERIES METAL TRIM/TRANSITION STRIP AT CARPET TO WOOD FLOORING. MATCH c HEIGHT OF WOOD. D DUTCH STYLE 1 2 -o B.INSTALL SS-1 (BRUSHED STAINLESS STEEL)ACCENT STRIP ON LIGHT COVE AT RECEPTION CHECK IN FINISH MATERIALS LEGEND 0 AND CHECK OUT DESKS. CODE PRODUCT MANUFACTURER MODEL NAME/NUMBER COLOR/FINISH SIZE REMARKS Drawing Title E 9.PROVIDE ACOUSTICAL UNDERLAYMENT AT WD-3 AND STAGGER JOINTS OF PLANKS IN A RANDOM PATTERN. ACTe ACOUSTIC CEILING GRID ARMSTRONG PRELUDE 15/16"HEAVY DUTY,24"X480 WHITE 2'X2' n ACT1 ACOUSTIC CEILING T1L.E ARMSTRONG FINE FISSURED,#1761 SECOND LOOK II WHITE WITH ANGLED TEGULAR EDGE,SCORED TO LOOK LIKE 2 X 2 2 X 2 FINISH LEGEND AND -a 10 BUILDING OWNER TO PROVIDE BUILDING STANDARD WINDOW COVERINGS AT ALL EXTERIOR WINDOWS. CPT CARPET SHAW CONTRACT PLAIN WEAVE 5T098 NATURAL SILK#99111 24"SQUARE TILE ASHLAR PATTERN,CENTER STRIPE AT HALLS SCHEDULES, 0 PROVIDE BLACKOUT SHADE AT ULTRASOUND 121, CG2 CORNER GUARD C/S ACROVYN VA-250N COLOR @ ACCENT P4 FAWN#196 21/2"X 4' 21/2"LEGS APPLIED WITH FOAM TAPE. DOOR SCHEDULE a0 - 11. PROVIDE A CEILING TRACK AND(1)PRIVACY CURTAIN PC1 AT OPENING TO ROOM 103. CG3 CORNER GUARD C/S ACROVYN VA-250N COLOR @ ACCENT P-2 OYSTER#929 2 1/2"X 4' 2 1/2"LEGS APPLIED WITH FOAM TAPE. 0 1:' 12. PROVIDE 4'-0"H.ACROVYN,VA SERIES WALL PROTECTION SHEETS ON BOTH THE NORTH AND EAST WALLS IN EP1 EPDXY PAINT,WATER BASED MILLER EPDXY AUGUST MOON 0194 1 ROOM 115 AROUND THE MOP SINK AND FAUCET, PROVIDE EDGE TRIM AT SIDES AND TOPS OF PANELS. EP2 EPDXY PAINT,WATER BASED SHERWIN WILLIAMS EPDXY BALANCE BEIGE SW7037 a EP3 EPDXY PAINT,WATER BASED SHERWIN WILLIAMS EPDXY TAVERN TAUPE SW7508 � ' 13. FABRIC(TB-1)WRAPPED HOMOSOTE PANELS TO BE ADHERED TO GYPSUM BOARD WALLS, REFER TO FRP1 FIRE RATED PLYWOOD NA NA NA INSTALL ON WALL IN IT CLOSET-DO NOT PAINT ELEVATIONS FOR LOCATION. PROVIDE EQUAL WIDTH PANELS WHERE MULTIPLE ARE NEEDED LVT-1 LUXURY VINYL PLANK MANNINGTON SPACIA NO VOC ADHESIVE SS5W254$WHITE OAK 4-1/2"X 36"PLANKS, STAGGER PLANKS RANDOM a LVT-2 LUXURY VINYL PLANK MANNINGTON AMTICO AROW7610 CLASSIC WALNUT 4-1/2"X 36"PLANKS STAGGER PLANKS RANDOM -a14.WHERE WC-13 IS INDICATED, WALLCOVERING TO BE WRAPPED AROUND JASCO,QUIET TOUCH ACOUSTICAL P1 PAINT MILLER SATIN LATEX AUGUST MOON 0194 GENERAL WALL,CEILING 2 3 3 5 '� • v PANEL MATERIAL, 1"THICK. PANELS TO BE INSTALLED TOP OF BASE TO CEILING USING Z CLIPS.PROVIDE EQUAL P2 PAINT SHERWIN WILLIAMS SATIN LATEX BALANCE BEIGE SW7037 g , ,Qf' as SIZED WIDTHS OF PANELS ON WALL INDICATED. REFER TO DETAILS 2&3/A8.2 P3 PAINT SHERWIN WILLIAMS SATIN LATEX TAVERN TAUPE SW7508 /1T ,. to P4 PAINT SHERWIN WILLIAMS SATIN LATEX PERSIAN FABLE 0259 • 1 ' r` tik* 'UAW, *REGO v` 03 00 PS PAINT SHERWIN WILLIAMS SATIN LATEX STORMY BAY 0484 1 PC1 PRIVACY CURTAIN STANDARD TEXTILE PATTERN: MIMOSA,#CM001501 COLOR:COOKIE 50%FULLNESS MOON IED TO HEADER AT OPENING 10 PHLEB 103 - , PL1 PLASTIC LAMINATE WILSONART 4965-38 BASKETWEAVE/VELVET TEXT OF - -c PL2 PLASTIC LAMINATE WILSONART 7971K-12 UPTOWN WALNUT U 0) a PL3 PLASTIC LAMINATE WILSONART 1573-60 FROSTY WHITE ao -8 PL4 PLASTIC LAMINATE WILSONART 4944-38 CASUAL LINEN �1 2 PL5 PLASTIC LAMINATE FORMICA 8824-58 WHITE DROPS Date: APRIL 23,2018 Q0 PL6 PLASTIC LAMINATE FORMICA 5875-58 NEUTRAL WEFT , ' f, PL7 PLASTIC LAMINATE PIONITE AC-561 CUBICLE PAPEL Job No: P24144.01 CU QT-1 QUARTZ STONE PENTAL PENTALQUARTZ BC 190P SPARKLING WHITE POLISHER 1-1/4"SLAB alI 1 RB1 RUBBER BASE JOHNSONITE 4"COVE STANDARD 179 STEEL 4"HIGH Drawn By JAN ECKELMAN ¢ 5 SS-1 STAINLESS STEEL HANSET STAINLESS BRUSHED FINISH Checked By: CLAUDIA STYMY E a T-1 TILE-WALL AT BACKSPLASH DESIGN AND DIRECT SOURCE SERIES: CLASSIC TILE,TRANSPARENT GLASS SPECIAL GREY-GLOSSY/MATTE BLEND 1/2"X 2"MOSIAC NON SANDED GROUT TO MATCH • .0 T,I TB-1 TACK BOARD,FABRIC WRAPPED JASCO GUILFORD OF MAINE SPINEL,PATTERN FR-701-2100 COLOR 144 EGGSHELL WIDTH: 66" ON TACK PANELS BETWEEN COUNTERS AND UPPERS oiiiaa) mi a) TS TRANSITION STRIP JOHNSONITE AS REQUIRED WHERE CARPET AND LVT MEET MATCH RB Drawing No. o• a WC-2 WALLCOVERING YORK-TRI-KES STACY GARCIA MAGNETIC STRIPE SG2455 ANTELOP WIDTH: 54" f I WC-8 WALLCOVERING MDC WALLCOVERING FIDDLEBACK BB-FB-17/4495 WESTERN SWING WIDTH: 54" `a WC-9 WALLCOVERING WOLF GORDON _GOH10062724 UNNEA FLOWER LNF 7-7152/EUBAUCHE WIDTH: 52" '`i WC-10 WALLCOVERING KNOLL TEXTILES OVERLAY WC1860/3 CORNERSTONE WIDTH: 53" N I WC-13 WALLCOVERING LUNA TEXTILES IDYLL,IDY-5423 ELM PAPER BACKED IF DIRECT GLUE,NO PAPER IF PANEL WRAPPED WIDTH: 54" SEE FINISH NOTE#15 0 U WD-1 WOOD PANELED WALL TO MATCH CONTROL SAMPLE EASTERN WALNUT 0)CO0 . I WD-2 WOOD BASE STAIN TO MATCH DOORS SELECT RIFT CUT WHITE OAK 1"x 4"H. STAINED TO ARCHITECTS SAMPLE Q'` A8MO 0 a..N�•0 WD-3 WOOD FLOORING NYDREE ACRYLIC INFUSED WOOD FLOOR FINISH WALNUT,PEDESTRIAN FINISH 15-20 4"W X 12"-46"L c:) a�'N WF WINDOW FILM SOLYX #SXJ-0561 FINE DOTS GRADIENT APPLY TO ALL RELITES AND GLASS PANELED DOORS 6 PERMIT SET oilC?w I 0 --5. 'rl 4) ...c ZG i::::'. ... ......., , , t,..... , / e I / / \ / / \ N. // ,' 1 "ct ( \ ZIMMER GUNSUL FRASCA ARCHITECTS LLP . 0 • ‘„‘„,----------\\ • • / / • / / I . irm--------------} • • 1 / / / a) ''',...... --...'....'N 1 / ..c BRACE PARTITION TO \\. PORTLAND (,) r-------_,1 / 1 SEATTLE i • \s.„-------",. STRUCTURE WITH . / \ 14, + : / LOS ANGELES KICKERS AS _-\--- t ,+ 1 / __-- \, , \ 1 / WASHINGTON DC — . (N) , -- REQUIRED --------- . ` , , , 1 \\\ + ,ir • „.------- CONT.METAL . NEW YORK r 1 t : ,..,, ;.,....i , 1 >.. ,......„ . _,...:::,.. ..) ;.:. \ , I Imo: 4 ! TRACK HEADER 0 . ,... ci k-.:.. = • -- . t, -.,- NI- 1 I (10 ',nom' to tit tit ••• •:.,--' .., •,.. :-::=1 hl III III PROVIDE GYPSUM BOARD AT ANY EXPOSED to IIIPSIP41,,,c,„_;;.; ca. m iii m m EXTERIOR WALL BETWEEN THE WINDOW HEADER 11 11101i' ''' ., -0 III m AND THE ACOUSTICAL CEILING, RETURN THE d0 NI iii GYPSUM BOARD TO THE WINDOW FRAME AND .,. • m m PAINT. iiii 111111 ru...::.),_ 0 ::,: Ill \- ,.. Revisions 0_ \L.. ACOUSTIC 7._ • 4 2 \ -5• 4 7.... .:.-,- '..7. INSULATION,48"-•'' A ta) v jii..a.._..1!4 til CEILING,SEE , . .2 -;- REFLECTED CEILING \\ -:-1! 4-••:, EACH SIDE OF 75 ill :if PLAN - ----- - - -- -' ; „4, PARTITION .,..., ....- .-‘ „„--- SOUND BATTS AT , ---- to ttt ,•,„::. --- ACOUSTIC .; • tit to .:-:- •,-'-'- PARTITIONS, Hi tit - "KNAUF 1 ti, iii EXISTING EXTERIOR WINDOW .• 4 :,- ' ,•-; QUIETHERM" .-0 (II MI-K., 7 z•-• r•S ..•.., o EXISTING EXTERIOR OF BUILDING. z--- 35/8"METAL STUDS, 0) . N'........7%., METAL BEAD CORNER. t, ::::....,,,J •:-.. ::-1.: 11110 1,,... T 1. ,,,,/ 5112"AT SIM. ../. 24"0.C.; 0 .., ------ , 1 1.,,e, /-"-----, ),I -..: PROVIDE GYPSUM BOARD AND PAINT , ,-- Cn _„. .- z— 5/8"TYPE X .2. .., AT VERTICAL FACE OF SILL WALL AND %iiri - , , 1\..,....-------Th •'' WRAP TO MEET WINDOW FRAME AT ,z/ GYPSUM BOARD r•-.. t EXTERIOR WINDOWS IN THIS SUITE. / 00 ../ ADD 1-5/8" FRAMING OVER EXTERIOR 0) ) • Z ,,---- CONT.METAL to 7---------,/ :.: SHEATHING BEFORE GYPSUM BOARD 1 WHERE OUTLETS ARE SHOWN IN TEAM t\SIOID.E808F.11ASCH T11111) -----, • , : ,,yz TRuNcNKERFL" (.0 r-----'---...,-/ OFFICE 104 AND 110 AND \ . , In 0 I ••• ANDROLOGY ON EXTERIOR WALLS. ., , (W. , I-•"/ ..4- • .... \ --- BASE PER FINISH 7 I\/ -4. ACOUSTIC SEALANT -------.\ ---------- SCHEDULE ' PROVIDE WALL BASE AS SCHEDULED. \ _ -- FINISH FLOOR ..c. c....• 5!)_ ', , t' . . 1:4------'. -1 ::-.---L'7"---11--. ---7‘ .1174:;::"71 CONT. 1 in"X 1/8" 4....-.- 3 SECTION - EXTERIOR WINDOW WALL .---."--• ,„' • GASKET TAPE ,.., • A8.1) 3"= 1%0" ----'— POWDER-DRIVEN al ANCHOR 0 . i . 0 . A8 1 SECTION - TYPE -1 TYPICAL INTERIOR PARTITION OREGON cn I . 3"=f-OK to PAINTED GYP BD REPRODUCTIVE ZA HEADER, SEE RCP 1 •.-: A . ..‘.%‘%...'..'<4,.. CONTINUOUS • MEDICINE ....1 BLOCKING NOTES: ) imommonott -. 0 . ,... O ,... ,.... 1 .. ----_____ SUITE 101 SCHEDULED CEILING <0 es GRABBER ACOUSTICAL SEALANT GSC .'-. ‘11141. ....__DEFLECTION 03 : :> , PO '-----rt . •'- . STI SPECSEAL SMOKE&SOUND ,.. HEAD AT TIGARD,OREGON 04 - . CI -1 • ; _ _ / - LAJ CAULK UNDERSIDE OF-', . / BOSS 824 ACOUSTICAL SEALANT • :-.: STRUCTURE • • . . ..... -,- • r. 0 . USE PUTTY PADS THAT MEET ..! Drawing Tide ›. EQ. clINEtt: ASTM E90-04-STI SPECSEAL SSP 4, NN... ,,s_GLAZING CHANNEL BOSS 818 PUTTY PADS 1 --" 11111110INTERIOR DETAILS \ CLEAR SEALANT, U.O.N. 3/8" TEMPERED GLASS T.> C 0 ...- C a c. )... 0 ,...,. ..... ,.,,.. 0 , _...., .... , ,.. 4 HEAD - RELITE @ MA 108 GLAZING bra -.1..- 1 11 4111111111 IIIIIIIIIIII g, 0) A8.1 SCALE: 3"=1'-0" I 0 CEILING,SEE -.: -:.? ,•.- . \ 1 , , .. 0 . ...--, REFLECTED CEILING I -;..-: ACOUSTIC PLAN eD-414 -4; ----------- . .7.. -,1 INSULATION,48" • 4., 2335 , -0 ,.. c , NOTES: , ; .. :-:• .::.'t 0 3/8" TEMPERED GLASS PARTITION 4., ,-.... .., ,-':' • / . • GLAZING CHANNEL ALL THROUGH PENETRATIONS 1 .e ' „ .."'''''----- SOUND BATTS AT CUL N 0, OREGON ...1,.. CX) EQ. 11 EQ. SHALL BE 1-HOUR DESIGNED, ... 00 ACOUSTIC PARTITIONS, 44* 00 0 TESTED AND FIRE RESISTIVE :•; ---;7,-,- "KNAUF QUIETHERM" .21,z. OF 1.1 :4.. -0 1 ASSEMBLY PER UBC STD.7-5. vi N ...., ,..,...----- * 3 5/8"METAL STUDS 11111111 ,a t, .‘-.;7-' - INSTALL ACCORDING TO THE ...... .4- *my AT 16"0.C. 4) al —- .13 (0 .._ \ 14> - ' -'`.::::: '---::-::-.:= LISTING.SEE UBC 709.6 FOR ...... 4„. I I ....... PLASTIC LAMINATE SILL. ADM. INFO . 1.- Aii011111 T: zi5 '1) 17-3\........—. I PL-1 (i. MA 108 _.7----- 518"TYPE X 1 13 m 1--- = , DUCT PENETRATIONS SHALL BE __ GYPSUM BOARD Date: APRIL 23,2018 0 ›. 11111101 PROTECTED AT CORRIDORS Job No: P24144.01 ONLY WHEN DUCT IS SERVING SETTING BLOCK CORRIDOR. Drawn By. JAN ECKELMAN _c 1 , 7- / FLOORCONTRUNNER METALNER TRACK (01 I . 0 c, Lill < c 1 CONTINUOUS Checked By: CLAUDIA S1NRSKY Z .„---- BASE PER FINISH BLOCKING c -76 7 /// SCHEDULE .00_, I . 1, 4-3/4". 1, G.) 0..., c) 0 .440 < ----- FINISH FLOOR Drawing No. 0 0 Pr) '''''',C,„ ./ 0 `" SMOKE SEALANT --------N. :::.."0 , I N.A P' ii 0 E(c. 5 SLL - RELITE @ MA 108 GLAZING , ,.- , .0.4___. •. .--. .... *. - "-- .2 ,"--7-----'-r---... A8.1 SCALE 3" = 1.-0" -V- 64---, '' - - ' ' ''' ------ • • - • '•:::-'-‘-..--- CONT. 1112"X 1/8" ...- ..c -. '2' ' - • ..., • , / GASKET TAPE A8 • 1 0,...„0.4. ANCHOR ----NM 2 SECTION TYPE 2 - INTERIOR PARTITION Q_ 0- ....-- PERMIT SET A8.1 3"= 1'-0" ....,..•it _92 0 Ix 1,-0" I' 1. ZG Fa _________:,,,_ QT-1 QUARTZ TRANSACTION i,,, . - COUNTER WITH EASED EDGES I r– ZIMMER GUNSUL FRASCA ARCHITECTS LLP QT-1 QUARTZ WATERFALL AT END OF TRANSACTION COUNTER AND AS A RETURN TO THE WORK . '�" iair SURFACE. POLISH ALL EXPOSED STAINLESS STEEL APRON SHOWN :tt 0_,_____,,) , POA D SIDES OF QUARTZ ►- BEYOND. - ! TLE LOS ANGELES \ __--------) L-' i ( i SEWASHINGTON DC rn ` t .;: ; NEIN YORK 04 f • 1 w� A `� « i' . ` 1 _ �` UNDERSIDE OF ACOUSTICAL CEILING —EASE ALL EXPOSED QUARTZ °r" "�` -% is EDGES ; ° 1 '_' _ COUNTER SUPPORT REQUIRED }• ` },;� � STAINLESS STEEL ANGLE 1 1/4 X 1 �: 4Z: t `' 1/4 X 1/4", FLAT EDGE, #4 FINISH 4' ATTACHED TO ALL SIDES OF PANEL PLAIN SLICED, SUP MATCHED NATURAL ' WALNUT WOOD VENEER PANEL ON 3 ` ` ' HORIZONTAL PANEL-HANGING CUPS Revisions +y, r'1 f4." w,' •J ::: PLAIN SLICED, EASTERN WALNUT `,,,,,, S. SHIM AS REQUIRED CUT-OUT FOR DATA CABLE M ) WOOD VENEER PANEL WD-1 ;: `) AND POWER MANAGEMENT +;: >•_: j; METAL WALL FRAMING REFER TO POWER FLOOR PLAN ` ` :4 FOR ELECTRICAL DEVICES x ::: . : ) ,,,,., ', a; ?._ CONTINUOUS STAINLESS STEEL ANGLE, REQUIRED. .;< GYPSUM BOARD I . 1 :,�, -- • .. ' 11 FLAT EDGE • M : METAL"STUD,20 GA 1-. . 3 5/8 0 1 -4 O.C. 8" MAX. 8" MAX. . 6'-0 MAX. 12'-0" MAX. . % LESSER OF 8" MAX q';�";� ' ge-9 ' ` ` 4'-0" MAX. ` ` ZO FI - OR 1/4" RUNNER LENGTH ,rOJPO �`'y,v / ' � j C� RATED CCG. FIXED SIDE ZIMMER GUNSUL FRASCA ARCHITECTS LLP � i_ ll'' 4 � • � a /g'� � � 4 " X X X X X X -44- PORTLAND t X I X X EXPOSED CROSS SEATTLE HANGER WIRE �` . SHEET METAL SCREWS " '`�\LX GRID MEMBER LOs ANGEES `� 1.5 TOTAL TRAVELWASHINGTON DC t P-' ,,- ` ....... —to i Q EXPOSED 21-0" O.CI NEW YORK __::.- ..e •_ _::....- o X X X X X X MAIN ome ID 5 d- .. ..:;moi o o a GRID MEMBER ± , - T. CREW LEFT S REIN TIGHTENED THROUGH C� 4'-O" O.C. ,. - `" ---� =' LOOSENED TO ALLOW HANGER WIRE 12GA - .- ,-0" MAIN RUNNER WEB " 9'-O" 11 , 1 , 1 1 ; 1 ; ': , ! , 1 I i ' i , 1 , I 1 , 1 , 1 ' 1 , 1 ; 1 1 , 1 , 1 1 1 : , H ` , i . i A / " RUNNER TO MOVE (B) RESTRICTING SEPARATION �. EACH1\ 4 -0 O.C. ` ( } FROM WALL MOLDING X X X WAY SEISMIC BERC 2 BERC 2 X X X X X X STRUT, SEE ACOUSTICAL CLEARANCE WALL INSTALLATION TIGHT WALL INSTALLATION PANEL CEILING • (FREE SIDE) (FIXED SIDE) 3/A8.90 AND Revisions 7'-2» "'�.. GYP BOARD FREE SIDE 4/A8.90 CUBICLE TRACK SEE RCP, SCREWS 2X#10 4 APC CEILING PERIMETER TO UNDERSIDE OF OPENING A8.3 SCALE: N.T.S. 1 TYPICAL ACP CEILING SUSPENSION 8 HEADER @ RECEPTION DESK AND ROOMS 101, 103, 108 A8.3 SCALE: N.T.S. A8.3 SCALE: 3" = 1'-0" 12'-0" MAX. 6'-0" MAX ` ` 4'--O" MAX. 0 RATED CLG. �, �, MAIN RUNNER 1 1/2" R 0 4-0 O.C. / FURRING CHANNEL P ® 1'-4" O.C. X --"A.-- X X X 9 NOT USED _ _ A8.3 SCALE: 3" = 1'-0" x m X -X X X X HANGER WIRE 8 GA i' ___. ® 4'-O" Q.C. o -- EACH WAY 1N X "--X-- X X X---- - -"" SEISMIC STRUT, SEE 3/A8.90 AND 4/A8.90 OREGON FASTEN TO GYP. BD. CEILING STRUCTURE REPRODUCTIVE CONCEALED HINGE = 5 NOT USED 2 TYPICAL GYP BD CEILING SUSPENSION , /-- --) 1:— ,. lit_ LATCH �. MEDICINEA8.3 SCALE: 3" = 1'-0" A8.3 SCALE: 3" = 1'-0" SUITE 101 ACCESS PANELZ . TIGARD,OREGON EDGE FLANGE FINISHED W/ SKIM COAT OF PLASTER #12 HANGER WIRE © 4'-O" .� 4 r BUILDING STRUCTURE #12 GA. SPLAY WIRE BRACING IN O.C. IN BOTH DIRECTIONS �, '� CONN, DEVICE - 100# CAPACITY Drawing Tide PLANE OF EACH RUNNER ALL HANGERS AND SPLAY APPROVED TYPE. SECURE TO 10 ACCESS PANEL IN GYP, BD. WHERE REQUIRED VERTICAL ANGLE - 45' (12' O.C. WIRES TO HAVE A MIN. OF 3 ° .� , : BUILDING STRUCTURE, CEILING DETAILS A8.3 SCALE: 3" = 1'-0" IN BOTH DIRECTIONS, 144 SQ. FT. 4- TURNS IN 1 OF RUN \ �, a MAX.) START WITHIN 4' OF WALL V NO. 20 GA. VERT. WIRE HCR. 45' TYPICAL 0 LEVEL CEILING GRID PRIOR VERTICAL SEISMIC STRUT - TO SETTING TUBE AT 12' 0.C. \ $^^ 1/2" ELECTRIC CONDUIT _ — (THIN WALL) �� '� .r/� 3/16" BOLT W/ LOCKING NUT \ \ ` / MAIN RUNN . �- = -_ --__ 4� 'ICAC \ \\ // // ._ 3/4" N ELECTRIC CONDUIT \\ *0 / / CROSS TEE (THIN WALL) ,t� \ / / LATERAL BRACING TO STRUCTURE ABOVE --4- SLOT TUBE TO FIT OVER ''1�~ 2335 �h IMAIN RUNNER CROSS RUNNERvi • /1: . a 6 SEISMIC STRUT "- NO.12 GA. SPLAY WIRE (4)-IN 141.1 , 1JrtE `e' I-- CURVED SOFFIT, PAINT P-1 SEE FLOOR c, PLAN FOR RADIUS, MATCH DESK A8,3 SCALE: NTS PLANE OF EA. RUNNER, VERT. IN BELOW. ANGLE APPROX. 45`', ALL WIRES4‘OF Q z SECURED TO RUNNERS APPROX. 2" FROM INTERSECTION 1 M NOTES: a - LIGHT FIXTURE L-6, LINK REQUIRED NUMBER OF FIXTURES TOGETHER TO UNIFORMLY EXTEND TUBE TO BE TIGHT TO CEILING GRID AND STRUCTURE ABOVE. Date: APRIL 23,2018 o ILLUMINATE THE COVE.. / " \ THEN INSTALL BOLT TO SECURE ONE TUBE TO THE OTHER. TUBES SHALL °° ,/ MAX. #12 GA. VERTICAL WIRE MAX. LAP ONE ANOTHER AT LEAST 4" IN FULLY EXTENDED POSITION. Jail No: PZ4144.01 - - ARMSTRONG AXIOM 10" TRIM EDGE Drawn By JAN ECKELMAN 1 // CEILING AREAS OVER 1,000 S.F. SHALL HAVE 4 WAY SPLAY BRACING PER DETAIL ABOVE. oWIRES TO BE TAUT AND YET NOT CAUSE CEILING UPLIFT. Checked By: CLAUDIA STYRSKY S E 5/8" GYP. BOARD OVER 3-5/8" METAL STUDS / O� o ...... ..........i . SUSPENSION SYSTEM SHALL COMPLY WITH IBC OREGON STRUCTURAL CODE. t ,_, -?� "'-- ►. COUNTERSLOPE MAIN HANGER WIRES IF MORE THAN 1:6 OUT OF PLUMB. cs " �` , Lek 9-0 ' i .` I lli . t ' i . i _ I ' ? , 4. f ' t i . l , ! . ~ . il ~ '. 1 . l ' ' , , i ' ' ' ' ' TYPICAL WEIGHTS: 0 U.N.O. LIGHT FIXTURES - 30# Drawing No. 9. SEE 613/A8.10- DIFFUSERS - 15# i SEE 6A/A8.10 EXIT SIGNS - 5# F57 E // ACOUSTICAL PANEL PROVIDE "TRAPEZE" AT DUCTWORK AND OTHER LARGE OBSTRUCTIONS. ill r 6" MAIN RUNNER OR CROSS TEE WALL ANGLE NOTES: - 7'-2" CEILING PER REFLECTED / 1. GRID: INTERMEDIATE WITH ALLOWABLE WT. OF FIXTURES = 70#, ACTUAL 2X4 FIXTURE WT. = 46#. Jr U.N.O. CEILING PLAN 2. PROVIDE HORIZONTAL STABAL IZER BAR, CONTINUOUS AT ALL PERIMETERS NOT POP RIVETED ai • TO WALL ANGLE. A8.3 CCN, METAL ANGLE TYP. CM i� ° (7s\ LIGHT COVE RECEPTION DESK METAL CORNER BEAD TYP. 7 APC SUSPENSION 3 SEISMIC STRUT • hi-' A8.3 SCALE: 3" = 1`-O" A$.3 SCALE: NTS A8.3 SCALE: NTS PERMIT SET CZ a_x