Loading...
Plans (379) BU P2017 - 00167 , CifS He alth . SPE AL INSP :L TIO'�i ..cit i EDRECEIVE State of Oregon Structural Specialty Code JUN 1 2017 CITY OF TIGARD • ' IP CVS I:3Concrete and Reinforcing Steel EK3olts Installed in Concrete BUILDING DIVISION ❑ Special Moment-Resisting Concrete Frame Healtil 7358 SW DURHAV1 ROAD PORTLAND , OR 97224 ❑ Reinforcing Steel&Prestressing Steel Tendons , _ ❑ Structural Welding• SCOPE OF WORK ❑ !-Iigh-Strenght Bolting CVS CORAM PORTLAND RENOVATIONS ❑ Structural Masonry THIS PROJECT INCLUDES THE RENOVATION OF AN EXISTING CLEAN ROOM SUITE STORE NUMBER 48140 1:::1 Reinforced Gypsum Concrete (COMPOUNDING, PREP ROOM AND COMPOUNDING ANTE), THE INSTALLATION OF A NEGATIVE CORAM, INC. El Insulating Concrete Fill PRESSURE SUITE (NEGATIVE PRESSURE ROOM AND ANTE) AND THE ADDITION OF 2 7358 S W DURHAM RD. ROOFTOOP UNITS. THE TENANT SPACE IS APPROXIMATELY 12,417 SF AND THE AREA OF ❑ Spray Applied F•o-Resistive Materials ALTERATION IS APPROXIMATELY 1,669 SF. THE PROJECT DOES NOT INCREASE THE SQUARE PORTLAND, OR 97224 FOOTAGE OF THE TENANT SPACE. THERE WILL BE A TEMPORARY CLEAN ROOM ERECTED PROJECT TYPE: PHARMACY ❑ Piiirtgs, C'tiled Piers and Caissons FOR USE DURING THE CONSTRUCTION OF THIS PROJECT, WHICH HAS BEEN PERMITTED . � � CVr1 DEAL TYPE: NPR ❑ Shotcrete SEPARATELY (BUP2017-00067). THIS SITE DOES NOT INCLUDE A RETAIL PHARMACY. I= Ez z z z z z w 0001:::3 Special c;radiz , Cxcavation and Filling CI- CS PROJECT NUMBER: 0106369 _J LJ -1 w J L,u m m m m m m m ❑ Smoke Control Systems J J J J J J . M CI Ci CI M ERS ❑ Over lnssctiorls ARCHITECT OF RECORD 0000000 n 0 0 0 0 0 o a V �--[ e � _ » � � = A WI N INDEXV III`VV/111PROJECT INFORMATIO \ � coV) V) V) V) V • CS COVER SHEET TENANT CVS/HEALTH, INC. ARCHITECT: GPD ENGINEERING AND ARCHITECTURE MECHANICAL/ STANTEC The building shall be in compliance with the: .401111 PROJECT PROFESSIONAL CORPORATION PLUMBING 2014 Oregon Structural Specialty Code (OSSC) ARCHITECTURAL MANAGER: 1 CVS DRIVE PAULA DESMARAIS 520 S. MAIN STREET MARK SALOPEK ENGINEER: 111 GRANT AVE. MIKE CUSHMAN 2014 Oregon Plumbing Specialty Code (OPSC) '■ A-0.1 SPECIFICATIONS SUITE 2531 TEL: (330) 572-2112 SUITE 201 TEL: (607) 321-6125 2014 Oregon Mechanical Specialty Code (OMSC) • A-0.2 SPECIFICATIONS SUITE 300 TEL: (401) 770-5398 ENDICOTT, NY 13760 2014 Oregon Electrical Specialty Code (OESC) GPD Engineering and Arlchitectu • A-0.3 SPECIFICATIONS WOONSOCKET, RI 02895 AKRON, OH 44311 MSALOPEK@CPDGROUP.COM 2014 Oregon Energy Efficiency Specialty Code (OEESC) Professional Corporation IN A-0.4 ACCESSIBLE CODE COMPLIANCE INFORMATION 520 South Main Street,Suite 2531 STRUCTURAL STANTEC ELECTRICAL STANTEC Akron,OH 44311 ■ A-1.0 OVERALL/EXITING PLANCONSTRUCTION CVS/HEALTH, INC. ENGINEER: ENGINEER: 330.572.2100 Fax: 330.572.2102 • A-1.1 DEMOLITION FLOOR PLAN PROJECT 111 GRANT AVE. SCOTT TUBES 111 GRANT AVE. VINCE FERRACCIOLI • A-1.2 DEMOLITION REFLECTED CEILING PLAN SUITE 201 TEL: (585) 413-5365 SUITE 201 TEL: (607) 321-6140 MANAGER: 4785 GRANITE DRIVE ERIK BRACONE • A-1.3 DEMOLITION ROOF PLAN TEL: (916) _1744 ENDICOTT, NY 13760 ENDICOTT, NY 13760 • A-1.5 REFECTED CEILING PLAN R PLAN ROCKLIN, CA 95677 ER K.BRA ONE@CVSHEALTH.COM RESPONSIBILITY SCHEDULE CONSULTANT ■ A-1.5a SEISMIC CEILING DETAILS TELECOMM & WO ENGINEERING GC CVS . • A-1.6 ROOF PLAN PERSONAL DIV DESCRIPTION r _ REMARKS _ MTOFTIGARD . • A-6.1 INTERIOR ELEVATIONS & DETAILS SECURITY: 155 SEAPORT BLVD. CHUCK CORRADIZ � FOR CODE COMPLIANCE • A-7.1 DETAILSL,_ - z SEAPORT W, FLOOR 2 TEL: (617) 443-4950 1 GENERAL REQUIREMENTS Approved* 1 � pd 1.t�1i�' ABBREVIATIONS (ABBREVIATIONS SHOWN ARE NOT BOSTON, MA 02210 TEL: (617) 443-4959 1. Permits and Fees X Includes building permit & tap fees STRUCTURAL ) NECESSARILY USED ON THE DRAWINGS and winter conditions if applicable and approved by CVS Project Permit# r re.... -die r� Manager and Director of -� .i n, • S- 1.0 STRUCT. INSTALLATION PARTIAL ROOF PLAN A _ Construction as an allowance. Address: S S( C (CONTINUED) F J N (CONTINUED) R T (CONTINUED) 8 OPENINGS - . .\ AB ANCHOR BOLT CJ CONTROL JOINT FA FIRE ALARM J BOX JUNCTION BOX NFPA NATIONAL FIRE PROTECTION1. Doors (Compound_ Suite) X X X Suite MECHANICAL PLUMBING AIR CONDITIONING CTR CENTER FACP FIRE ALARM CONTROL PANEL JT JOINT ASSOCIATION RA RETURNADAIR THRU THROUGH NAI: OH PACE ``� AC ALTERNATING CURRENT CV CHECK VALVE FCO FLOOR CLEANOUT JST JOIST RAD RADIUS T THERMOSTAT By: Dattel 1 ` NIC NOT IN CONTRACT RCP REFLECTED CEILING PLAN, TYP TYPICAL 2. Doors (NPR) X X X / • M-0.1 MECHANICAL LEAD SHEET ACC ACCESSIBLE CW COLD WATER FD FIRE DAMPER, FLOOR DRAIN NL NIGHT LIGHT RD ROOF DRAIN T THICKNESS (STRUCT BY HODESS ACI AMERICAN CONCRETE INSTITUTE FIN FINISH (ED) K NO NUMBER RE: REFERENCE, REFER TS TUBULAR STEEL (STRUCT) ■ M-0.2 MECHANICAL GENERAL NOTES ADA AMERICANS WITH DISABILITIES ACT D FIXT FIXTURE NOM NOMINAL REINF REINFORCING TRS TRUSS (STRUCT) 9 FINISHES ADJ ADJUSTABLE FDN FOUNDATION k KIPS (1000 LBS) NTS NOT TO SCALE READ REQUIRED 1. Resilient Flooring X X X NAI: ARMSTRONG • M-1.0 MECHANICAL SPECIFICATIONS AFF ABOVE FINISHED FLOOR DBL DOUBLE FLG FLANGE kV KILOVOLT RO ROUGH OPENING RPM REVOLUTIONS PER MINUTE AISC AMERICAN INSTITUTE OF STEEL CONS. DC DIRECT CURRENT FTG FOOTING kVA KILOVOLT-AMPS 0 2. Flooring Sealant X X • M-1.1 MECHANICAL DEMO/INSTALL PARTIAL FLOOR PLANS ALUM ALUMINUM DEG DEGREES FE FINISHED FLOOR kW KILOWATT UL UNDERWRITERS DEVELOPER. DEFS DIRECT-APPLIED EXTERIOR FLR FLOOR kWH KILOWATT-HOUR RTU ROOFTOP UNIT • M-1.2 MECHANICAL DEMO/INSTALL PARTIAL ROOF PLANS AMP AMPERE, AMPS OA OUTSIDE AIR LABORATORIES, INC. ARCH ARCHITECT, ARCHITECTURAL FINISH SYSTEM FR FIRE-RETARDANT- OC ON CENTER UON UNLESS OTHERWISE NOTED 3. Paint X X X NAI: BENJAMIN MOORS • M-2.0 MECH. AIR FLOW DIAGRAM & PRESSURIZATION PLAN ASHRAE AMERICAN SOCIETY OF HEATING, DIA DIAMETER TREATED MATERIALS L OCC OCCUPANTS S UPS UNINTERRUPTIBLE • M-2.1 MECHANICAL DETAILS & SCHEDULES REFRIGERATION AND AIR DIM DIMENSION FRP FIBERGLASS REINFORCED LB POUNDS OF OUTSIDE FACE SCHED SCHEDULED POWER SUPPLY 11 EQUIPMENT CONDITIONING ENGINEERS DL DEADLOAD PANEL LF LINEAR FEET OD OUTSIDE DIAMETER SD SMOKE DAMPER, 1. Compounding Pass-through X X X NAI: TERRA UNIVERSAL • FP-1.0 FIRE PROTECTION DEMO/INSTALL PARTIAL FLOOR PLANS ASTM AMERICAN SOCIETY OF TESTING AND DN DOWN FT FOOT. FEET LL LIVE LOAD, LANDLORD OH OPPOSITE HAND STORM DRAIN V OFFICE COPY MATERIALS DS DOWNSPOUT C LW LONG LEG HORIZONTAL OPNG OPENING SECT SECTION V VOLT 2. NPR Carts, tables X X X NAI: EAGLE ■ P-0.1 PLUMBING LEAD SHEET DTL DETAIL V LLV LONG LEG VERTICAL OSB ORIENTED STRAND BOARD 5 SENSOR VA VOLT-AMPERE • P-1.0 PLUMBING INSTALLATION PARTIAL FLOOR PLANS B DWGS DRAWINGS GA GAUGE LONG LONGITUDINAL OSHA OCCUPATIONAL SAFETY AND SF SQUARE FEET VERT VERTICAL E HEALTH ADMINISTRATION SHT SHEET 3. Negative Pressure Room X _ X X BY HODESS s BLDG BUILDING GALV GALVANIZED LP LOW POINT VIE VERIFY IN FIELD ELECTRICAL BM BEAM GC GENERAL CONTRACTOR LTG LIGHTING P SIM SIMILAR VRC VERTICAL RECIPROCATING EA EACH GB GRADE BEAM 1 SHT MIL SHEET METAL CONVEYOR 4. Hazardous Drug Refrigerator X X X NAI: Heilmer Horizon H-Unit BOTT BOTTOM LWC LIGHT WEIGHT CONCRETE SPEC SPECIFiCATkON BTU BRITISH THERMAL UNIT EF EXHAUST FAN GWB GYPSUM WALL BOARD L LENGTH PAR PARALLEL VTR VENT THROUGH ROOF EXPANSION JOINT SQ SQUARE BOF BOTTOM OF FOOTING GAB GRADED AGGREGATE BASE PC PIECE 22 PLUMBING ■ E-a.1 ELECTRICAL LEAD SHEET ELEV ELEVATION GYP GYPSUM WALL BOARD �/� PDU POWER DISTRIBUTION UNIT SS STAINLESS STEEL, BRG BEARING ,r' 1. Sink X X X NAI: EAGLE EFS EXTERIOR INSULATION AND PH PHASE SANITARY SEWER • E-1.0 ELECTRICAL SPECIFICATIONS C FINISH SYSTEM H MAX MAXIMUM PL PLATE STD STANDARD ■ E-1.1 ELECTRICAL DEMO/INSTALL PARTIAL FLOOR PLANS ELEC ELECTRICAL MDP MAIN DISTRIBUTION PANEL PLBG PLUMBING STL STEEL w/ WITH2. FEET 2. Eyewash fixture X X X NAI: EAGLE CF CUBIC EMBED EMBEDMENT HGT HEIGHT MECH MECHANICAL PNL PANEL STIFF STIFFENER W/O WITHOUT __E.■ E-1.2 ELECTRICAL DEMO/INSTALL PARTIAL ROOF PLANS CD CONDENSATE EP EMPLOYEE HORIZ HORIZONTAL MEZZ MEZZANINE Ply POST INDICATOR VALVE STIR STIRRUPS WCO WALL CLEANOUT 23 MECHANICAL CERTS CERTIFICATES EHIS ENERGY MANAGEMENT SYSTEM HP HORSEPOWER OR HIGH POINT MFR MANUFACTURER PSF POUNDS PER SQUARE FOOT STRUCT STRUCTURAL WC WATER CLOSETSEAL' ED MIN MINIMUM PVC POLYVINYL CHLORIDE WD WOOD 1. Hoods X X X NAI: BAKER ■ E-2.0 ELECTRICAL SCHEDULES CFM CUBIC FEET PER MINUTE SNCL ENCLOSURE HTR HEATER SUSP SUSPENDED ,C V e INE-2.1 ELECTRICAL ONE-LINE DIAGRAM CKT CIRCUIT CENTERLINE EOD EQ EDGE OF DECK EQUAL HVAC HEATING, VENTILATING AND AIR CONDITIONING MLO MO MAIN LUGS ONLY MASONRY OPENING PWD PLYWOOD SJ SAW JOINT WL WP WIND LOAD WEATHERPROOF 2. FFU's (Compound. Suite) X X NAI: FNVIRCO. ti� f� LG CEILING EQUIP EQUIPMENT MSB MAIN SWITCHBOARD 0 WO WALL OPENING U 1 ARN S 5:11.01'1:K TT1 CLR CLEAR OR CLEARANCE EXGR EXTERIOR GRADE I MTD MOUNTED T WWF WELDED WIRE FABRIC 3. FFU's (NPR) X X X NAI: BY HODESS L PHYSICAL SECURITY & TELECOM CMU CONCRETE MASONRY UNIT EXH EXHAUSTWF WIDE FLANGE STRUCT CO CLEANOUT EXP EXPANSION ID INSIDE DIAMETER QTY QUANTITY T&B/F TOP AND BOTTOM (STRUCT) AKRON, OH ,� COL COLUMN EXIST EXISTING IE INVERT ELEVATION N T/FTG TOP OF FOOTING �/ 4. RTU (Compound. Suite) X X X NAI: ENGINEERED AIR • PS a.1 PHYSICAL SECURITY LEGEND INT INTERIOR N/ATEMP TEMPERATURE /� • • CONC CONCRETE, CONCENTRIC EXT EXTERNAL, EXTERIOR NOT APPLICABLE NU. 6038 • PS-2.1 PHYSICAL SECURITY SPECIFICATIONS CONT CONTINUOUS, CONTINUATION EW EACH WAY IN INCH, INCHES NEC NATIONAL ELECTRICAL CODE THICK THICKNESS 5. RTU (NPR) - X X X NAI: ENGINEERED AIR 3 THRESH THRESHOLD XFMR TRANSFORMER CDORp COORDINATE EWC ELECTRIC WATER COOLER INSUL INSULATION NEMA NATIONAL ELECTRICAL ■ PS-2.2 PHYSICAL SECURITY SPECIFICATIONS MANUFACTURER'S ASSOC. TO TOP OF '� „ w NF NEAR FACE TOJ TOP OF JOIST 26 ELECTRICAL -0!7-7§ThNt A Lu ■- PS-2.3 PHYSICAL SECURITY SPECIFICATIONS TOS TDP of STEEL Y 1 Interior Lighting X� X X Or relocated. NAI: NESCO �� 'fliO ■ PS-3.1 PHYSICAL SECURITY CONSTRUCTION PLAN YD YARD " V) _ ■ PS-4.1 PHYSICAL SECURITY DETAILS 2. NPR Lighting X X X BY HODESS ■ T-0.1 TELECOMMUNICATIONS LEGEND 3. Intercom X X REFER TO LOW VOLTAGE DWGS 06/12/2017 • T-2.1 TELECOMMUNICATIONS SPECIFICATIONS 4. Low Voltage X X X ■ T-2.2 TELECOMMUNICATIONS SPECIFICATIONSGENERAL PROJECT NOTES ale. cc to coordinate with NAI: INN04 CC TO CARRY lNNa4 CPM on bids. REVISIONS: ■ T-2.3 TELECOMMUNICATIONS SPECIFICATIONS 5 Security x X X NM: Stanley GC TO CARRY . M ■ T-3.1 TELECOMMUNICATIONS CONSTRUCTION PLAN Stanley BID. n coordinate PROVIDE EITHER with CPM on bids, •IE T-4.1 TELECOMMUNICATIONS DETAILS _ 1. CONTRACTORS SHALL NOT SCALE THESE DRAWINGS FOR CONSTRUCTION PURPOSES. IN THE FLEXIBLE SPRINKLER ■ T-4.2 TELECOMMUNICATIONS DETAILS EVENT OF OMISSION OF NECESSARY DIMENSIONS OR INFORMATION, CONTRACTOR SHALL NOTIFY 17. PAINT ALL WALL SURFACES, DOOR FRAMES, BULKHEADS AND CEILINGS IN ROOMS WHERENOTE. REFER TO NON-RETAIL SUPPLIER TAKE-OFF LIST FOR NAI CONTACT HEAD OR 2-INCH ■ T-4.3 TELECOMMUNICATIONS DETAILS ARCHITECT. FIGURED AND CALCULATED DIMENSION TAKES PRECEDENCE OVER SCALED INDICATED ON ROOM FINISH SCHEDULE. PAINT BEHIND ALL MOVEABLE ITEMS ADJACENT TO WALLS INFORMATION. NON-RETAIL SUPPLIER TAKE-OFF LIST TO BE SUPPLIED BY CVS a MEASUREMENTS. DETAILED DRAWINGS AND LARGER SCALE DRAWINGS TAKE PRECEDENCE OVER RECEIVING PAINT AND RELOCATE ITEMS. CONSTRUCTION PROJECT MANAGER. ; OV>:RS1Lh RiNGS .:::; E SMALLER SCALE DRAWINGS. ALL PLAN DETAILS AND WALL SECTIONS ARE ASSUMED TO BE • OR. INTERP 10-01 00 TYPICAL CONDITIONS UNLESS DETAILED OR NOTED OTHERWISE. 18. ALL WEATHER -- EXPOSED SURFACES SHALL HAVE A WEATHER RESISTIVE BARRIER TO 0 PROTECT THE INTERIOR WALL COVERING. EXTERIOR OPENINGS SHALL BE FLASHED IN SUCH A 0 2. ALL FINISHED FLOOR ELEVATIONS RE: TO ARCHITECTURAL DRAWINGS ONLY. RE: CIVIL MANNER AS TO MAKE THEM WATERPROOF. 47,- DRAWINGS FOR RELATIONSHIP TO PROJECT BENCHMARK(S). POWER DRIVEN SHOT1N LOCATION V AP 0 19. ALL WOOD BLOCKING TO BE TREATED. ANCHORS USED v, 3. VERIFY ALL DIMENSIONS, CONDITIONS, AND GRADES AT JOB SITE. ALL CONTRACTORS SHALL "' SEISMIC APPLICATION o COORDINATE THEIR WORK WITH OTHER TRADES AND REPORT DISCREPANCIES, PRIOR TO THEIR 20. DEMOLITION & CONSTRUCTION MUST BE SEQUENCED & COORDINATED TO INSURE THAT THE SHALL REQUIRE SPECIAL CONSTRUCTION, TO THE ARCHITECT FOR REVIEW AND CLARIFICATION OR ACTION. BUILDING BUSINESS OPERATIONS ARE MAINTAINED. COORDINATE ALL WORK WITH BUILDING ix MANAGEMENT PRIOR TO PROCEEDING. INSPECTION ,,:;::::' i 4, VERIFY SIZE, LOCATIONS AND CHARACTERISTICS OF ALL EQUIPMENT TO BE FURNISHED WITH _. .. OR.INTI:RP10Of MANUFACTURERS OR SUPPLIERS BEFORE BEGINNING CONSTRUCTION. 21. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS FOR EXTERIOR AND n INTERIOR DOORS. KEY PLAN i 5. VERIFY SIZE AND LOCATION OF ALL OPENINGS FOR MECHANICAL AND ELECTRICAL EQUIPMENT 1- AND RELATED WORK WITH CONTRACTORS INVOLVED AND EQUIPMENT TO BE FURNISHED. FOR 22. PROVIDE SEMI-RECESSED FIRE EXTINGUISHERS. LOCATIONS AND CLASSIFICATIONS OF EXTINGUISHERS cc CONSTRUCTION DETAILS NOT SHOWN, USE THE MANUFACTURER'S STANDARD DETAILS OR SHALL BE IN ACCORDANCE WITH CFC 906 AND CALIFORNIA CODE OF REGULATIONS (CCR), TITLE 19. DRAWING BY: APPROVED SHOP DRAWINGS / DATA SHEETS IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS. 0 0 23. ALL RECEPTACLE DEVICES AND FACE PLATES TO MATCH EXISTING. RE: MEP. ., ,, DATE: June 6, 2017 6. CEILING HEIGHTS SCHEDULED ON THE ROOM FINISH SCHEDULE OR REFLECTED CEILING PLAN ARE -- TAKEN FROM THE FINISHED FLOOR ELEVATION. 24. ASCERTAIN THE EXTEND OF WORK NECESSARY TO NOT ONLY ACHIEVE THE AESTHETIC INTENT, BUT ALSO i SYMBOLS 7. ALL PLAN DIMENSIONS ARE TO FINISHED FACE OF FINISHED WALLS, FACE OF MASONRY, AND TO COMPLY WITH GOVERNING CODES & REGULATIONS, WHICH MAY REQUIRE ADDITIONAL WORK AND/OR ,�° JOB NUMBER: 2016285.50 o _o CENTERLINE OF COLUMNS, UNLESS NOTED OTHERWISE. EQUIPMENT. TITLE: rnN m 8 . VERIFY ALL ELEVATIONS AND DIMENSIONS OF STRUCTURAL ELEMENTS WITH ARCHITECTURAL 25. ORDER ALL PARTS NECESSARY FOR INSTALLATION OF FIXTURES SPECIFIED, U.O.N. •• DRAWINGS. IN CASE OF CONFLICT, NOTIFY ARCHITECT. THE CONTRACTORS SHALL VERIFY ALL /"v1' - . 0 CENTERLINE Mk ENLARGED PLAN DIMENSIONS AND BE RESPONSIBLE FOR THEM. ALL DIMENSIONAL DISCREPANCIES ARE TO BE 26. PROVIDE COORDINATING MECHANICAL, ELECTRICAL, AND PLUMBING WORK REQUIRED FOR PROPER FUNCTION COVER SHEET o �, OF COLUMN f _ A-7. DETAIL MARK BROUGHT TO THE ATTENTION OF THE ARCHITECT. OF ALL FIXTURES AND EQUIPMENT. RE: MEP. co I I 13. COORDINATE WITH MECHANICAL CONTRACTOR FOR LOCATIONS OF ALL FLOOR DRAINS. 27. CLEAN AND PREPARE SLAB TO ACCEPT FINISHES. G.C. TO CONFIRM AND REPORT MOISTURE CONTENT TO SHEET NUMBER: C CN `-- - tel 14. ALL PLUMBING WET WALLS (EXCLUDING CHASES) SHALL BE FRAMED WITH 6" METAL STUDS. ARCHITECT PRIOR TO FINISH WORK. SECTION MARK PROJECT AREA �� ����N t o aAI © 15. ALL PRODUCTS UTILIZED IN THIS CONSTRUCTION SHALL BE ASBESTOS FREE. 28. PROVIDE DETECTION SYSTEM, EMERGENCY LIGHTING AND EXIT SIGNS AS REQUIRED BY GOVERNING CODES, C ELEVATION 'SIM' - SIMILAR RULES, AND REGULATIONS. RE: MEP. API.\ SMr7; o MARK A-5' 'OH' - OPPOSITE 16. TRANSITION OF DIFFERENT FLOORING MATERIALS AT DOORWAYS SHALL OCCUR AT CENTERLINELo II HAND OF DOORS TYPICALLY. 29. GC TO COMPLY WITH CONSTRUCTION SITE MAINTENANCE GUIDELINES OF LOCAL JURISDICTION. NORTH NORTH 0 COMMENTS: II Il E O � °- N 0 - � O Li .D. -\jerIcy 5rKAII rive per rurrrI uui,ieur l.urILIuCcl,ur . PROJECT SPECIFICATIONS 2. Date. 2. Professional Engineer Qualifications: A professional engineer who is legally qualified to practice in jurisdiction where Project is F. Auxiliary Services: Cooperate with testing agencies and provide 3. Name and address of Contractor, located and who is experienced in providing engineering services auxiliary services as requested, including the following: DIVISION 00 - CONTRACT DOCUMENTS 4. Name and address of subcontractor or supplier. of the kind indicated. 1. Access to the Work. C2Ckfa SECTION 00 40 00 - GENERAL CONDITIONS 5. Number and title of appropriate Specification Section. C. Submittals: Testing agency shall submit a certified written report 2. Incidental labor and facilities to assist inspections and tests. of each inspection and test to Owner, Architect, Contractor, • C. Architect will review each action submittal, mark as appropriate Structural and to authorities havin jurisdiction when 3. Adequate quantities of materials for testing, and assistance in The General Conditions of this contract shall be the AmericanEngineer, Institute of Architects, (Hereinafter referred to as the A.I.A.), to indicate action taken, and return copies less those retained. authorities so direct. Reports of each inspection, test, or taking samples. Compliance with specified requirements remains Contractor's similar service shall include the following: Document No. A201, "General Conditions of the Contract for the 4. Facilities for storing and curing test samples. recIponsibility. Health Construction", Latest Edition, Articles I through 14. These 1. Name, address, and telephone number of testing agency. 5. Security and protection for samples and test equipment. paragraphs are intended as an alternative to the inclusion of AIA v. c..onstruction bcneduie buOmittal t-'rocedure: 2. Project title and testing agency's project number. Document No. A201, Latest Edition and such document shall be 1. Submit schedule within 14 days after date established for �p p, made a part of the contract documents with the same force and Commencement of the Work. Distribute copies to Owner, 3. Date of report and designation (number). PART 2 - PRODUCTS (Not Applicable) STORE NUMBER: • 48140 effect as though set forth in full. The General Conditions and all Architect, subcontractors, and parties required to comply with 4. Dates and locations where samples were taken or inspections CORAM, INC. supplements, amendments and modifications listed hereinafter dates. and field tests made. shall apply to the general contract and all sub-contracts. PART 3 - EXECUTION (Not Applicable) 7358 S W DURHAM RD. 2. Revise the schedule after each meeting or activity where 5. Ambient conditions at the time of sample taking and inspecting PORTLAND, OR 97224 revisions have been made. As Work progresses, mark each bar or field testing. - _, __ ,.___. .... , ,,.. . __ . , t• o indicate actual completion. Distribute revised copies to PROJECT TYPE PHARMACY Owner, Architect, subcontractors, and parties required to é. Names of individuals taking the sample or making the END OF SECTION O1 40 00 DEAL TYPE: NPR comply with dates. inspection or test. CS PROJECT NUMBER: 0106369 END OF SECTION Cl 10 00 7. Product and test method. SECTION 01 50 00 - TEMPORARY FACILITIES AND CONTROLS • 6. Inspection or test data including interpretation of test results SECTION 01 20 00 - PRICE AND PAYMENT PROCEDURES and comments or professional opinion on whether inspected or ARCHITECT OF RECORD PART 2 - PRODUCTS PART 1 - GENERAL tested Work complies with requirements. 2.1 ACTION SUBMITTALS q. Recommendations on retesting or reinspection. PART 1 - GENERAL 1.1 SECTION REQUIREMENTS A. Product Data: Mark each copy to show applicable choices and 10. Name and signature of laboratory inspector. options. Include the following: A. Use Charges: Contractor shall pay use charges for temporary 1.1 CONTRACT MODIFICATION PROCEDURES p g: D. Testing Agency Qualifications: Agencies that specialize in the utilities. Z-........1.111°.°1111116; 1. Data indicating compliance with specified standards and types of inspections and tests to be performed and are A. On Owner's approval of a proposal from Contractor, Contractor re uirements. acceptable to authorities having jurisdiction. B. Standards: Comply with ANSI A10.6, NECA's 'temporary Electrical will issue a Change Order on AIA Document G701, for all changes q Facilities, " and NFPA 241. GPD Engineering and Architecture to the Contract Sum or the Contract Time. 2. Notation of coordination requirements. E. Testing Agency Responsibilities: Testing agency shall cooperate with Architect and Contractor in performing its duties and shall 1. Electrical Service: Comply with NEIVIA, NECA, and UL Professional Corporation B. When Owner and Contractor disagree on the terms of a proposal, 3. For equipment data, include rated capacities, dimensions, provide qualified personnel to perform inspections and tests. standards and regulations for temporary electric service. Install 520 South Main Street,Suite 2531 Architect mayissue a Construction Change Directive on AIA weights, required clearances, and furnished specialties and service to comply with NFPA 70. Akron,OH 44311 g g qp p y 330.572.2100 Fax:330.572.2102 Document G714, instructing Contractor to proceed with the accessories. 1. Agency shall promptly notify Architect and Contractor of change. Construction Change Directive will contain a description deficiencies in the Work observed during performance of its C. Temporary Utilities: At earliest feasible time, when acceptable to of the change and designate the method to be followed to B. Shop Drawings: Submit Project-specific information drawn to services. Owner, change over from use of temporary service to use of determine changes to the Contract Sum or the Contract Time. scale. Do not base Shop Drawings on reproductions of the permanent service. Contract Documents or standard printed data. Submit PDF's on 2. Agency shall not release, revoke, alter, or enlarge CONSULTANT: sheets at least 8-1/2 by 11 inches (215 by 280 mm) but no requirements of the Contract Documents nor approve or accept 1.2 PAYMENT PROCEDURES larger than 30 by 42 inches (762 by 1%7 mm). Architect will any portion of the Work. A. Submit a Schedule of Values at least 10 days before the first return a markup up PDF. Include the following: 3. Agency shall not perform duties of Contractor. Application for Payment. In Schedule of Values, break down the PART 2 - PRODUCTS 1. Dimensions, profiles, methods of attachment, large scale Contract Sum into at least one line item for each Specification - Section. Correlate the Schedule of Values with Contractor's details, and other information, as appropriate for the Work. 2.1 EQUIPMENT Construction Schedule. 2. Identification of products and materials. A. Heating Equipment: Unless Owner authorizes use of permanent B. Submit 3 copies of each application for payment on AIA 3. Notation of coordination requirements. heating system, provide vented, self-contained heaters with Document 0702/703, according to the schedule established in 4. Notation of dimensions established by field measurement. thermostatic control. Owner/Contractor Agreement. 1. For the second Application for Payment through the Application C. Samples. Submit Samples finished as specified and identical with I. Use of gasoline-burning space heaters, open-flame heaters, or for Payment submitted at Substantial Completion, submit the material proposed. Where variations are inherent in the salamander-type heating units is prohibited. material, submit sufficient units to show full range of the partial releases of liens from each subcontractor or supplier 2. Heating Units: Listed and labeled, by a testing agency for whom amounts were included in the previous Application variations. Provide (3) three of each sample and include name o acceptable to authorities having jurisdiction, and marked for , for Payment. manufacturer and product name on label. intended use for type of fuel being consumed. DEVELOPER• 2. Submit final Application for Payment after completion of 2.2 INFORMATION SUBMITTALS Project closeout procedures with release of liens and supporting documentation. Include consent of surety to final payment and A. Construction Schedule: Prepare a horizontal bar-chart Contractor': PART 3 - EXECUTION insurance certificates. construction schedule. 3.1 TEMPORARY UTILITIES a. Submit final meter readings for utilities, a record of stored 1. Provide a separate time bar for each activity, using same fuel, and similar data as of the date of Substantial breakdown of Work indicated in the Schedule of Values, and a A. General: Engage appropriate local utility company to install Completion. vertical line to identify the first workday of each week. temporary service or connect to existing service. Where utility company provides only part of the service, provide the -) (,,.,r,l-.,4 e= ...,.-k .°i.o.-,.,or,+ .,,,+1, +1,,,o, +,,,;+,Gar- al ,, ,-1,, remainder. _ 2. Coordinate each element with other activities. Show each PART 2 - PRODUCTS (Not Applicable) activity in proper sequence. Indicate sequences necessary for B. Sanitary Facilities: Provide temporary toilets, wash facilities, and completion of related Work. drinking-water fixtures. Comply with regulations and health codes N PART 3 - EXECUTION (Not Applicable) for type, number, location, operation, and maintenance of SEAL: 3. Indicate Substantial Completion and allow time for Architect's fixtures and facilities. �D A procedures necessary for certifying Substantial Completion. 41eC. Heating and Cooling: Provide temporary heating and cooling `� END OF SECTION 01 20 00 B. Product Certificates: Prepare written statements onrequired for curing materials or for protecting installed "�� r� manufacturer's letterhead certifying that product complies withconstruction from adverse weather. Use equipment that will not U MARK S.S:1I,01'I:I{ requirements. have a harmful effect on completed installations or elements AKRON OH SECTION 01 30 00 - ADMINISTRATIVE REQUIREMENTS being installed. • NO. 6036 • 01 PART 3 - EXECUTION (Not Applicable) �� oi a PART 1 - GENERAL 3.2 TEMPORARY FACILITIES � elQ � .20 Ar co A. Provide field offices, storage trailers, and other support facilities /��- , 7��A a END OF SECTION 01 30 00 as necessary for the Work. 1.1 PROJECT MANAGEMENT AND COORDINATION B. Collect waste daily and, when containers are full, legally dispose 06/I2/2017 n A. Coordinate construction to ensure efficient and orderly installation SECTION 01 40 00 - QUALITY REQUIREMENTS of waste off-site. i of each part of the Work. REVISIONS: I. Handle hazardous, dangerous, or unsanitary waste materials in B. Conduct progress meetings at Project site every two (2) weeks. separate closed waste containers. Dispose of material according CD Notify Owner and Architect of meeting dates and times. Require PART 1 - GENERAL to applicable laws and regulations. 0 attendance of each subcontractor or other entity concerned with ycurrent progress or involved with planning or coordination of C. Provide temporary enclosures for protection of construction and future activities. 1.1 SECTION REQUIREMENTS workers from inclement weather and for containment of heat. E A. Testingand inspecting services are required to verifycompliance 0 1. Record minutes and distribute to parties involved, including p g qD. Install project identification and other signs in locations approved o with requirements specified or indicated. These services do not byOwner to inform thepublic andpersons seekingentrance to Owner and Architect. o relieve Contractor of responsibility for compliance with the Project. Do not permit installation of unauthorized signs. " 1.2 SUBMITTAL PROCEDURES Contract Document requirements. N 1. Testing and inspecting services are specified in other Sections 3.3 TEMPORARY CONTROLS 0 A. Coordinate each submittal with fabrication, purchasing, testing, of these Specifications or are required by authorities having delivery, other submittals, and related activities that require A. Provide temporary environmental controls as required by a jurisdiction and shall be performed by independent testing authorities havingjurisdiction including, but not limited to, erosion i sequential activity. agencies. g' 01 and sediment control, dust control, noise control, and pollution czi1. No extension of the Contract Time will be authorized because 2. Owner will provide testing and inspecting services not specified control. of failure to transmit submittals enough in advance of the to be provided by Contractor. 1-- Work to permit processing. B. Provide temporary barricades, warning signs, and lights to 0 3. Contractor is responsible for scheduling inspections and tests protect the public and construction personnel from construction DRAWING BY: 2. Architect will not accept submittals from sources other than and notifying testing agency. Contractor. hazards. 0 4. Retesting and Reinspecting: Contractor shall pay for additional 1. Enclose construction areas with fences with lockable entrance DATE: June 6, 2017 3. Identify deviations from the Contract Documents. testing and inspecting required as a result of tests and gates, to prevent unauthorized access. CD JOB NUMBER: 2016285.50 LO 4. Submit PDF's of each submittal. inspections indicating noncompliance with requirements. s C. Provide temporary fire protection until permanent systems supply B. Place a label or title block on each submittal for identification. B. Performance and Design Criteria: Where design services or fire-protection needs. Comply with NFPA 241. TITLE: N Provide a 4- by 5-inch (100- by 125-mm) space on the label certifications by a professional engineer are required by the - ,, or beside title block to record review and approval markings and Contract Documents, provide products and systems complying 3.4 TERMINATION AND REMOVAL SPECIFICATIONS - o i action taken. Include the following information on the label: with specific performance and design criteria indicated. A. Remove temporary facilities and controls before Substantial `V "' 1. If criteria indicated are not sufficient toperform services or Completion. Personnel remainingafter Substantial Completion will r- 1. Project name. p p SHEET NUMBER: • o - - , certification required, submit a written request for additional be permitted to use permanent facilities, under conditions - i information to Architect. acceptable to Owner. / O >, , A 0N • N 0 4 >2 O END OF SECTION 01 50 00 . COMMENTS: II ii E 0 IUB (1) 0 °� I / I , - regulations, or standards referenced. I. Flame Spread: 25, maximum. SECTION 01 60 00 - PRODUCT REQUIREMENTS NOT USED C. Unless otherwise indicated, Architect will select color, pattern, 2. Smoke Developed: 450, maximum. cr27: - CVS and texture of each product from manufacturer's full range of PART 1 - GENERAL options that includes both standard and premium items. DIVISION 05 - METALS 1.4 SUBMITTALS SECTION 05 50 00 - METAL FABRICATIONS A. See Section 01100 - General Requirements, for submittal 1.1 SECTION REQUIREMENTS PART 3 - EXECUTION (Not Applicable) PART 1 - GENERAL procedures. Health A. Provide products of same kind from a single source. The term B. Product Data: Manufacturer's data sheets on each product to be . "product" includes the terms "material, " "equipment, " "system, " used, including: and similar terms. END OF SECTION 01 GO 00 1.1 SECTION REQUIREMENTS A. Submittals: Shop Drawings showing details of fabrication and B. Product Substitutions: Substitutions include products and methods 1. Preparation instructions and recommendations. of construction differingfrom that required bythe Contract installation. 2. Storage and handling requirements and recommendations. q SECTION 01 70 10 - EXECUTION AND CLOSEOUT REQUIREMENTS STORE NUMBER 48140 Documents and proposed by Contractor after award of the 3. Installation methods. • Contract. CORAM, INC. PART 2 - PRODUCTS C. Verification Samples: For each film specified, two samples 1. Submit four (.4) copies of each request forproduct PART 1 - GENERAL 7358 S W DURHAM RD. p q representing actual film color and pattern. substitution. PORTLAND, OR 97224 2.1 METALS D. Warranty: Submit manufacturer warranty and ensure that forms 2. Submit requests within 30 days after signing the Contract. 1 - GENERAL have been completed in Owner's name and registered with PROJECT TYPE: PHARMACY A. Steel Plates, Shapes, and Bars: ASTM A 36/A 36M. DEAL : NPR 3. Submit requests in time to permit processing of request and manufacturer. subsequent submittals, if any, sufficiently in advance of when 1.1 CLOSEOUT SUBMITTALS (COMPLY WITI-1 TDS1-IS B. Steel Tubing: Cold-formed steel tubing complying with ASTM A J 500. 1.5 QUALITY ASSURANCE CS PROJECT NUMBER: 0106369 REQUIREMENTS WI-IERE REQUIRED [Texas only])materials are required in the Work. Do not submit unapproved Y ) substitutions on Shop Drawings or other submittals. A. Record Drawings: Maintain a set of the Contract Drawings as C. Steel Pipe: ASTM A 53, standard weight (Schedule 40), black A. Manufacturer Qualifications: All primary products specified in this finish. section will be supplied bya single manufacturer with minimum ARCHITECT OF RECORD 4. Identify product to be replaced and provide complete Record Drawings. Mark to show installation that varies from the pp 9 documentation showing compliance of proposed substitution with Work originally shown. 10 years experience. applicable requirements. Include a full comparison with the 2.2 GROUT pp re q p B. Operation and Maintenance Data: Organize data into three-ring B. Installer Qualifications: All products listed in this section are to specified product, a list of changes to other Work required to binders with identification on front and spine of each binder and A. Nonshrink, Nonmetallic Grout: ASTM C 1107; recommended by be installed by a single installer with a minimum of five years accommodate the substitution, and any proposed changes in the pocket folders for folded sheet information. Include the manufacturer for exterior applications. demonstrated experience in installing products of the same type Contract Sum or the Contract Time should the substitution be followin and scope specified. accepted. 9 2.3 FABRICATION A.6116 5. Architect will review the proposed substitution and notify 1. Manufacturer's operation and maintenance brochures. 1.6 PROJECT CONDITIONS A. General: Shear and punch metals cleanly and accurately. Remove Contractor of its acceptance or rejection. 2. Emergency instructions. burrs and ease exposed edges. Form bent-metal comers to A. Maintain environmental conditions (temperature, humidity, and GPO Engineering Architecture C. Comparable Product Submittal: 3. Spare parts list. smallest radius possible without impairing work. ventilation) within limits recommended by manufacturer for • Professional Corporation optimum results. Do not install products under environmental 520 South Main Street,Suite 2531 1. Submit four (4) copies of each request for approval of 4. Wiring diagrams. B. Welding: Weld corners and seams continuously. Use materialsAkron,OH 44311 products as comparable to basis-of-design products. Submit and methods that minimize distortion and develop strength and conditions outside manufacturer's recommended limits. 330.572.2100 Fax:330.572.2102 5. Copies of warranties. corrosion resistance of base metals. At exposed connections, in time to permit processing of' request and p subsequent submittals, if any, sufficiently in advance of when 4. Product MSDS documentation finish welds and surfaces smooth with contour of welded surface PART 2 - PRODUCTS materials are required in the Work. Do not submit unapproved matching those adjacent. products on Shop Drawings or other submittals. C. Fabricate ladders for locations shown, complying with ANSI A14.3, 2.1 MANUFACTURERS CONSULTANT' 2. Identify product to be replaced and provide complete PART 2 - PRODUCTS (Not Applicable) welded steel construction. A. 3M Window Film, 3m Center Building 0235-02-5-27; St. Paul, documentation showing compliance of proposed product with D. Fabricate loose lintels from steel angles and shapes. Size to MN 55144-1000; Tel: 846-499-8857 applicable requirements. Include a full comparison with the provide bearing length at each side of openings equal to specified product. one-twelfth of clear span, but not less than 8 inches (200 PART 3 - EXECUTION 2.2 PRODUCTS 3. Architect will review the proposed product and notify mm). Contractor of its acceptance or rejection. A. 3M Privacy Film Series, 3M White Matte Translucent film. 3.1 EXAMINATION AND PREPARATION E. Fabricate steel pipe columns with steel base and top plates D. Deliver, store, and handle products using means and methods drilled for anchor and connection bolts and welded to pipe with that will prevent damage, deterioration, and loss, including theft. A. Examine substrates and conditions for compliance with continuous fillet weld same size as pipe wall thickness. PART 3 - EXECUTION Comply with manufacturers written instructions. manufacturer's written requirements including, but not limited to, surfaces that are sound, level, plumb, smooth, clean, and free F. Fabricate pipe bollards from Schedule 80 steel pipe and fill 1. Schedule delivery to minimize long-term storage at Projectsolidly with concrete, rounding top surface. of deleterious substances; substrates within installation tolerances; 3.1 EXAMINATION site and to prevent overcrowding of construction spaces. and application conditions within environmental limits. Proceed 2. Deliver products to Project site in manufacturer's original with installation only after unsatisfactory conditions have been 2.4 STEEL AND IRON FINISHES A. Film Examination: corrected. sealed container or packaging, complete with labels and A. got-dip galvanized steel fabrications 1. If preparation of glass surfaces is the responsibility of another instructions for handling, storing, unpacking, protecting, and B. Verify9 layout information shown on Drawings, in relation to installer, notify Architect in writing of deviations from DEVELOPER: y installin B. Prepare uncoated ferrous metal surfaces to comply with manufacturer's recommended installation tolerances and property survey and existing benchmarks, before laying out the SSPC-SP 3, "Power Tool Cleaning," and paint with a 3. Inspectproducts on deliveryto ensure compliance with the Work. conditions. p rust-inhibitive primer complying with performance requirements Contract Documents and to ensure that products are undamagedC. Prepare substrates and adjoining surfaces according to in FS TT-P-444. a. Glass surfaces receiving new film should first be examined and properly protected. manufacturer's written instructions, including, but not limited to to verify that they are free from defects and imperfections, 4. Store materials in a manner that will not endanger Project filler and primer application. which will affect the final appearance. structure. D. Take field measurements as required to fit the Work properly. PART 3 - EXECUTION proceed 2. Do not with installation until glass surfaces have been 5. Store products that are subject to damage by the elements, Where fabricated products are to be fitted to other construction, properly prepared and deviations from manufacturer's 3.1 INSTALLATION recommended tolerances are corrected. Prepare surfaces using cover in a weathertight enclosure above ground, with verify dimensions by field measurement before fabricating and, p ventilation adequate to prevent condensation. when possible, allow for fitting and trimming during installation. A. Perform cutting, drilling, and fitting required for installing the methods recommended by the manufacturer for achieving miscellaneous metal fabrications. Set metal fabrication accurately the best result under the project conditions. 3.2 CUTTING AND PATCHING in location, alignment, and elevation, with edges and surfaces 3. Commencement of installation constitutes acceptance of SEAL: \V,D AR PART 2 - PRODUCTS level, plumb, true, and free of rack. C' A. Do not cut structural members or operational elements without conditions. c� �.. prior written approval of Architect. B. Fit exposed connections accurately together to form hairline iJ~ MARKS. 5:1T.01'I:K�-t1 2.1 PRODUCT OPTIONS B. For patching, provide materials whose installed performance will joints. 3.2 PREPARATION AKRON, OH A. Provide products that comply with the Contract Documents, are equal or surpass that of existing materials. For exposed surfaces, C. Coat concealed surfaces of aluminum that will come into contact • H• with masonry, wood, or dissimilar metals with A. Clean surfaces thoroughly prior to installation. • NO. 6036 ' undamaged, And are new at the time of installation. provide or finish materials to visually match existing adjacent grout, concrete, y, tJ� 0, surfaces to the fullest extent possible, a heavy coat of bituminous or epoxy paint. B. Prepare surfaces using the methods recommended by the I 1. Provide products complete with accessories, trim, finish, and manufacturer for achieving the best result for the substratevi yother devices and components needed fora complete /0" A�3.3 INSTALLATION under the project conditions. 1 0. installation and the intended use and effect. END OF SECTION 05 50 00 C)- A. Comply with manufacturer's written instructions for installation. C. Refer to Manufacturer's installation instructions for methods of Q B. Select products to comply with all of the following that are 06/12/2017 Anchor each product securely in place, accurately located and preparation for Impact Protection Adhesive or Impact Protection lc a) applicable: aligned. Clean exposed surfaces andprotect from damage. If Profile film attachment systems. 9 p 9 DIVISION 06 - WOOD PLASTICS n 1. Where only a single product or manufacturer is named, provide applicable, prepare surfaces for teld finishing. REVISIONS: o the item indicated. No substitutions will be permitted. SECTION 06 10 00 - ROUGH CARPENTRY B. Clean Project site and work areas daily, including common areas. 3.3 INSTALLATION 02. Where two or more products or manufacturers are named, U provide one of the items indicated. No substitutions will be 3.4 FINAL CLEANING PART I - GENERAL A. Film Installation, General: i permitted. 1. Install in accordance with manufacturer's instructions. A. Clean each surface or item as follows before requesting inspection E)c 3. Where products or manufacturers are specified by name, for certification of Substantial Completion: 1.1 SECTION REQUIREMENTS 2. Cut film edges neatly and square at a uniform distance of 1/8 accompanied by the term "available products" or "available inch (3 mm) to 1/16 inch (1.5 mm) of window sealant. Use omanufacturers, " provide one of the named items or comply I. Remove labels that are not permanent. A. Submittals: Model code evaluation reports for treated wood, and new blade tips after 3 to 4 cuts. 0 with provisions for "comparable product" to obtain approval for 2. Clean transparent materials, including mirrors. Remove excess engineered wood products. 0 use of an unnamed product or manufacturer. glazing compounds. Replace chipped or broken glass. 3. Spray the slip solution, composed of one capful of baby 2 shampoo or dishwashing liquid to 1 gallon of water, on window C 4. Where a single product is named as the "basis-of-design" 3. Clean exposed finishes to a dust-free condition, free of stains, PART 2 - PRODUCTS glass and adhesive to facilitate proper positioning of film. 0 c) together with the names of other manufacturers, provide the films, and foreign substances. Leave concrete floors broom a named product or comply with provisions for "comparable clean. 4. Apply film to glass and lightly spray film with slip solution. 2.1 HOOD PRODUCTS, GENERAL 3 product submittal" to obtain approval for use of a product of 4. Vacuum carpeted surfaces and wax resilient flooring. 5. Squeegee from top to bottom of window. Spray slip solution to 0 one of the other named manufacturers. Select subparagraph A. Lumber: Provide dressed lumber, 545, lq percent maximum film and squeegee a second time. cx above or first subparagraph below if "basis of design" products 5. Wipe surfaces of mechanical and electrical equipment. Remove moisture content for 2-inch nominal (38-mm actual) thickness 1-- are specified. excess lubrication. Clean plumbing fixtures. Clean light fixtures or less marked withgrade stampof inspection agency. G. Bump film edge with lint-free towel wrapped around edge of a CC p and lamps. p 5-way tool. DRAWING BY: 5. Where a single product is named as the "basis-ofGesign" and B. Hood Structural Panels: DOC PS 2. Provide plywood complying 7. Upon completion of film application, allow 30 days for 0no other manufacturers are named, provide the named product G. Clean the site. Sweep paved areas, remove stains, spills, and with DOC PS 1, where plywood is indicated. DATE: June 6, 2017 moisture from film installation to dry thoroughly, and to allow a or comply with provisions for "comparable product submittal" foreign deposits. Rake grounds to a smooth, even-textured film to dry flat with no moisture dimples when viewed under o to obtain approval for- use of aproduct of another surface. 1 . Comply with "Code Plus" provisions in APA Form No. E30K. JOB NUMBER: 2016285.50 m 0 ppnormal viewing conditions. manufacturer. 0 3.5 CLOSEOUT PROCEDURES 8. If completing an exterior application, check with the TITLE: o = G. Where a product is described with required characteristics, manufacturer as to whether edge sealing is required. o > provide a product that complies with those characteristics. A. Substantial Completion: Before requesting Substantial Completion SPECIFICATIONS c) inspection, complete the following: '� i 7. Where compliance with performance requirements is specified, N provide products that comply and are recommended in writing 1. Advise Owner of pending insurance changeover requirements.00 3.4 CLEANING AND PROTECTION by the manufacturer for the application. 2. Submit specific warranties, maintenance agreements, and A. Remove left over material and debris from Work area. Use SHEET NUMBER: N similar documents. necessary means to protect film before, during, and after 3 to installation. 0 >,E N 2 i B. Touch-up, repair or replace damaged products before Substantial 0 . 2 D Completion. II L. ii ii E C. After application of film, wash film using common window COMMENTS: 0 4) c N O - 0 cleaning includingammonia solutions, 30 days after C. Edge Strips: Rubber in maximum available lengths to minimize solutions, yoints color as selected. 2. Length to suit project conditions. application. Do not use abrasive type cleaning agents and bristle ARCHITECTURAL MATERIAL SPECIFICATION S brushes to avoid scratching film. Use synthetic sponges or soft 8. Adhesive: Either of the following construction adhesives _ C -,-moi-- complying with ASTM C 557. FOR COMPOUNDING SUITE -- - =- PART 3 - EXECUTION - 1 WS 1.1 SECTION REQUIREMENTS 1. Marlite C-551 FRP Adhesive - Water- resistant, DOORS AND FRAMES: A. Submittals: Product Data and material Samples. Class A tiles non-flammable adhesive. P 3.1 INSTALLATION 1. PROVIDE MANUFACTURER'S PHARMACEUTICAL GRADE UNITS WITH REQUIRED HARDWARE; INCLUDING DOOR have a flame-spread index of 25 or less; Class 8, 75 or less. 2. Marlite C-375 Construction Adhesive - Flexible, CLOSER, STAINLESS STEEL FRAME AND HINGES, PULL HANDLE, PUSH PLATES, CLOSURES, LOCKS AND Mostroducts are Class A. A. Prepare concrete substrates according to ASTM F 710. Verify water-resistant, solvent based adhesive, formulated for fast, ACTUATION DEVICES. DOOR MODULE SIZE TO BE APPROXIMATELY 3' X T. Health that substrates are dry and free of curing compounds, sealers, easy application. B. Surface-Burning Characteristics of Panels: ASTM E 1264, Class A and hardeners. 2.VISION PANELS: PROVIDE MANUFACTURER STANDARD HALF GLASS VISION PANEL IN THE DOORS WITH materials, tested per ASTM E 84. 3. Titebond Advanced Polymer Panel Adhesive - VOC compliant, TEMPERED GLASS. WINDOWS SHALL BE A DOUBLE FLUSH GLAZED UNIT WITHOUT EDGE TRIM. B. Lay out tiles so tile widths at opposite edges of room are equal non-flammable, environmentally safe adhesive. and are at least one-half of a tile. 3. THE DOOR FRAMES SHALL BE A FLUSH DETAIL TO THE CLEANROOM WALL THE FRAMES SHALL BE 1.2 NATIONAL ACCOUNT C. Sealant: CONSTRUCTED USING A SLIM-LINE STAINLESS STEEL PROFILE WHICH IS PREFABRICATED, WELDED AND �p p C. Match tiies for Gator and pattern by selecting tiles from cartons , _Rr �- - �, • DRESSED TO ELIMINATE ALL CREVICES. THE FRAMES SHALL BE SINGLE PIECE FRAMES FINISHED IN 304 STORE NUMBER:. 48140 A. CVS/Pharmacyhas entered into a national account agreement g in same sequence as manufactured and packaged. Lay tiles in STAINLESS STEEL. • with Armstrong World Industries, Inc. for furnishing the acoustical basket-weave pattern with grain direction alternating in adjacent CORAM, INC. ceiling and grid specified in this section. Complete installation tiles, in patterns indicated. 4.ASI/CLEANSEAL EXCEL MODEL #220 PHARMACEUTICAL MOLDED FIBERGLASS DOOR WITH CLEANVIEW 7358 S W DURHAM RD. shall be by the Contractor. For pricing quotations, placing orders, FLUSH WINDOW (OR APPROVED EQUAL). PORTLAND, OR 97224 and further information, call Armstrong at (800) 442-4212. D. Clean and wax flooring per manufacturers recommended installation instructions. Turn over floor to owner with 5. DOOR SWEEP (IF REQUIRED) PEMKO # 321SSN STAINLESS STEEL. PROJECT TYPE PHARMACY manufacture's suggested number of wax coats. DEAL TYPE NPR 6.FOR REPLACING PREP ROOM DOORS LEADING TO NON-CLEAN SPACES, USE CHASE FIB-R-DOOR WITH PART 2 - PRODUCTS END OF SECTION 09 65 10 STAINLESS STEEL FRAME AND SLIMLINE VISION KIT. CS PROJECT NUMBER: 0106369 WINDOW UNITS: • 2.1 ACOUSTICAL TILE 1. THE GLAZED UNITS SHALL BE SIZED TO MATCH EXISTING OPENINGS. UNITS SHALL BE FABRICATED AS A. Products: SECTION 049 65 20 - 1-10MOGENEDUS SI-IEET VINYL FLOOR TWIN FLUSH GLAZED WINDOWS PROVIDING AN OVERALL WIDTH TO ACHIEVE A FLUSH, LEDGE-FREE ARCHITECT OF RECORD 1. Refer to Drawings. COVERINGS FINISH. FACTORY FABRICATED WITH 5/32'TEMPERED GLASS SHEETS AND ASSEMBLED AND SEALED ONTO STAINLESS STEEL SUB-FRAME. GLAZING SHALL BE FINISHED WITH A 7/8"BLACK BORDER AT THE B. Edge Detail: Square. PERIMETER EDGES. WINDOW UNITS SHALL BE FRAMELESS, GLAZED UNITS FINISHED FLUSH WITH THE C. Thickness: 5/8 inch. PART I - GENERAL WALL PANEL FACES. D. Size: Per Drawings. FRP PANELS: 6. 1.1 SECTION INCLUDES 1. CRANE FIRE-X GLASS BOARD FSFM; 0.075 INCH THICK, FM APPROVED, CLASS A FIRE RATING, SMOOTH �® E. NFPA Class: A WALL PANELS. COLOR #85 - WHITE. INCLUDE ASSOCIATED JOINT AND CORNER TRIM. A. Moisture Control System GPD Engineering andArchitecture 2.2 SUSPENSION SYSTEM PRE-MANUFACTURED COVES: Professional Corporation B. Homogeneous resilient sheet vinyl flooring. 1. 3"RADIUS UPVC EXTRUDED SECTIONS WITH VACUUM FORMED CORNER PIECES AND WHITE PVC WELDED 520 South Main Street,Suite 2531 A. Ceiling Suspension System: Direct Hung, ASTM C 635. Akron,OH 44311 SEAMS. COLOR: WHITE. 330.572.2100 Fax:330.572.2102 1. 1.2 NOT USED. Products: SEALANT: a. Refer to Drawings. 1.3 REQUIREMENTS OF REGULATORY AGENCIES 1. DOW CORNING #732 RTV MULTI -PURPOSE SILICONE CAULK SEALANT. COLOR: WHITE. B. Attachment Devices: Size for 5 times the design load indicated in A. File Test Response: Resilient sheet vinyl flooring shall have a 2. SPRAY SEALANT - 3M FIREDAM SPRAY 200. CONSULTANT' ASTM C 635, Table 1, Direct Hung, unless otherwise indicated. critical radiant flux classification of Class I, not less that 0.45 FOAM FILLER: C. Wire Hangers, Braces, and Ties: Zinc-coated carbon-steel wire; 1. 3M FIRE BARRIER RATED FOAM FIP 1-STEP. ASTM A 641/ (A 641M), Class lzinc coating, soft temper. L.,. If ISLUI l Wu<< UUbC If r r iuxir r!ur r lCr ic(Lr i� PU iviC. r-Nppiy Lv wu<<', columns, pilasterscasework, and other permanent fixtures in INSULATION 1. Size: Provide yield strength at least 3 times the hanger design rooms or areas where base is required. 1. OWENS CORNING R-13 ECOTOUCH FLAME SPREAD 25 BATT INSULATION WITH load (ASTM C 635, Table 1, Direct Hung), but not less than 0.135-inch- (3.5-min-) diameter wire. D. Install reducer strips at edges of floor coverings that would FOIL-SCRIM-KRAFT (FSK) FACING. otherwise be exposed. VAPOR BARRIER PART 3 - EXECUTION 1. CERTAINTEED MEMBRAIN CONTINUOUS AIR BARRIER AND SMART VAPOR RETARDER. END OF SECTION 09 65 30 FLAME SPREAD MAX. = 20 3.1 INSTALLATION SMOKE DEVELOPED = 55 A. Ceiling Suspension System Installation: Comply with ASTM C 636 USE MANUFACTURER RECOMMENDED TAPES AND SEALANTS FOR A COMPLETE and C1SCA's "Ceiling Systems Handbook." AIRTIGHT SEAL SUSPENDED CEILING SYSTEM: DEVELOPER: END OF SECTION 09 51 20 SECTION Oq II 20 - DECORATIVE FIBERGLASS REINFORCED IAIALL 1. GORDON DS-20 GASKETED 2" CLEANROOM GRID; HIGH PERFORMANCE POWDER PANELS COAT WHITE FINISH, WITH OPTIONAL HOLD DOWN CLIPS AND CONTINUOUS COVE TRIM AT WALL CEILING INTERSECTIONS. 24 1/2" x 48 1/2" LAYOUT MODULE. SECTION 0q 65 10 - RESILIENT FLOOR TILE PART 1 - GENERAL 2. CERTAINTEED PERFORMA ENVIROGARD VINYL FACED GYPSUM PANELS; 2' X 4' X 1, CLASS A RATED, ITEM # 1190-CRF-1. CAULK EACH INDIVIDUAL CEILING PART 1 - GENERAL 1.1 SUMMARY PANEL TO GRID ON ALL FOUR SIDES AND CAULK CEILING PANELS TO PERIMETER COVE WITH SILICONE CAULK SEALANT. 1.1 SECTION REQUIREMENTS A. Section Includes: Prefinished polyester glass reinforced plastic sheets and adhered to unfinished gypsum wallboard. , A. Submittals: Product Data and Samples. 1. PVC trim. B. Fire Test Response: Resilient tile has critical radiant flux SEAL. D classification of Class I, not less than 0.45 W/sq. cm. 1.2 REFERENCES : (S )r- A Q, 1.2 NATIONAL ACCOUNT B. American Society for Testing and Materials: Standard .4 ,1AItIiS.S:1I.0I'F.k• rn Specifications (ASTM) , C., A. CVS/Pharmacy has entered into a national account agreement AKRON, OH ti 1. ASTM D 5319 - Standard Specification for Glass-Fiber with the suppliers below for furnishing and installing the vinyl • NO 6038 • products as specified on the "Interior Finish Schedules." For Reinforced Polyester Wall and Ceiling Panels. tP pricing quotations, placing orders, and further information, call 2. ASTM E 84 - Standard Test Method for Surface Burning 1 .fi C v 0 fir the appropriate supplier for the area the store is located in. Characteristics of Building Materials. f = i I N 1. Interface Services at (770) 975-4819. 1 o PART 2 - PRODUCTS i a. Areas: AL, AZ, CO, CT, DC, DE, GA, ID, IL, IN, HI, LA, 06/12/2017 v MA, MD, ME, MN, MS, MT, ND, NH, NJ, NM, NY, NV, 2.1 ACCEPTABLE MANUFACTURER s OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, NA, i NV, NY A. Marlite; 202 Harger Street, Dover, OH 44622. 800-377-1221 REVISIONS: 0FAX (330) 343-4668 Email: info@marlite.com www.marlite.com. -. 2. Mannington Commercial at (706) 602-6551. 0 a. Areas: AR, MI, NI 8. Product: i 1. Standard FRP U) 3. MATS Inc. at (781) 573-0292. S a. Areas: IA, KS, KY, NC, NE 2.2 PANELS 0 A. Fiberglass reinforced thermosetting polyester resin panel sheets o = complying with ASTM D 5319. 0 PART 2 - PRODUCTS 0 B. Properties: Resistant to rot, corrosion, staining, denting, peeling, co and splintering. 0 1. Color: 100 White rx a. 2. Texture: Smooth, front and back. --- 2.1 VINYL COMPOSITION FLOOR TILE 3. Fire Rating: Class C i C_) ..I V I I Ni I L `....•L.,i 1 I t../..J I I I L/I V I 1-l/4/N. 1 11..I... o A . Products: 2.3 MOLDINGS DRAWING BY: 0 1, Refer to Finish Schedule on Drawings. A. PVC Trim: Thin-wall semi-rigid extruded PVC. DATE: June 6, 2017 o_ B. Color and Pattern: Refer to Finish Schedule. 1. M 350 Inside Corner, C8' length3C10' length] Q i C. ASTM F 1066, Class 2 (through-pattern tile). 2. Color: White JOB NUMBER: 2016285.50 a TITLE: o = D. Nearing Surface: Smooth. 2.4 ACCESSORIES o >U E. Thickness: 1/8 inch (3.2mm). A. Fasteners: Non-staining nylon drive rivets. SPECIFICATIONS o F. Size: 12 by 12 inches (304.8 by 304.8 mm). 1. Match panel colors. 0°,in 2. Length to suit project conditions. ''' SHEET NUMBER: 0 2.2 INSTALLATION ACCESSORIES 0 A o �, D A. Trowelable Leveling and Patching Compounds: Latex-modified, -= o i portland cement- or blended hydraulic cement-based formulation ,, 3 w o a provided or approved by flooring manufacturer for applications i a indicated. i COMMENTS: II II o B. Adhesives: Nater-resistant type recommended by manufacturer to N 0 suit resilient products and substrate conditions indicated. no ()SIGNS 0 ()ACCESSIBLE ROUTE A. WHEN SIGNS IDENTIFY PERMANENT ROOMS AND SPACES OF A BUILDING OR SITE, 11.1 _ THEY SHALL COMPLY WITH SECTIONS 1 THRU 6 BELOW. 0 0 A. AN ACCESSIBLE ROUTE SHALL BE PROVIDED FROM PUBLIC STREETS SIDEWALKS B. WHEN SIGNS DIRECT TO OR GIVE INFORMATION ABOUT PERMANENT ROOMS AND - Q- z AND PUBLIC TRANSPORTATION STOPS TO THE ACCESSIBLE ENTRANCE. - -_ _ SPACES OF A BUILDING OR SITE, THEY SHALL COMPLY WITH SECTIONS 1 & 2 7i = O o = BELOW. d- O 1 0 ®WALKS AND SIDEWALKS = _ C. WHEN SIGNS IDENTIFY, DIRECT OR GIVE INFORMATION ABOUT ACCESSIBLE ELEMENTS A. WALKS AND SIDEWALKS SHALL HAVE A CONTINUOUS COMMON SURFACE NOT AND FEATURES, THEY SHALL COMPLY WITH SECTION 1 Sc 2. SEE FIGURE BELOW. </ - X i ♦ INTERRUPTED BY STEPS OR BY ABRUPT CHANGES IN LEVEL EXCEEDING 1/4 ti INCH (PER 303 OF ICC A117.1-2009), AND SHALL BE A MINIMUM OF 3 FEET IN 1. FINISH & CONTRAST. CHARACTERS, SYMBOLS Sc THEIR BACKGROUND SHALL �, WIDTH. HAVE A NON-GLARE FINISH. CHARACTERS & SYMBOLS SHALL CONTRAST - O N \ _ / -' X k) Health WITH THEIR FIELD, EITHER LIGHT ON DARK BACKGROUND OR DARK ON LIGHT d- X r < N © ± B. WALKING SURFACE SLOPE SHALL NOT EXCEED 1:20 WITH CROSS SLOPES SHALL BACKGROUND. m Q m <t- x N © , NOT EXCEED 1:48 (PER 403.3 OF ICC A117.1-2009). 2. PROPORTIONS. CHARACTERS ON SIGNS SHALL BE SELECTED FROM FONTS I ° ?Ni IC. WALKS, SIDEWALKS AND PEDESTRIAN WAYS SHALL BE FREE OF GRATING WHERE THE WIDTH OF THE UPPERCASE LETTER "0" IS 55 PERCENT MINIMUM \ / \ \ \ \ \ WHENEER POSSIBLE. FOR GRATINGS LOCATED IN THE SURFACE OF ANY OF AND 110 PERCENT MAXIMUM OF THE HEIGHT OF THE UPPERCASE LETTER MIRROR BABY -AUTOMATIC TOILET SEAT THESE AREAS, GRID OPENINGS IN GRATINGS SHALL NOT ALLOW PASSAGE OF 'I"• CHANGING HAND DRYER COVER 1/2 SPHERE. STORE NUMBER: 48140 3. RAISED CHARACTERS & PICTORAL SYMBOL SIGNS. STATION DISPENSER D. WHEN THE SLOPE IN THE DIRECTION OF TRAVEL OF ANY WALK EXCEEDS 1 CORAM, INC. a. CHARACTER TYPE. CHARACTER ON SIGNS SHALL BE RAISED 1/32" -TOWEL {EA. STALL) VERTICAL TO 20 HORIZONTAL IT SHALL COMPLY WITH THE PROVISIONS FOR (0.794mm) MIN AND SHALL BE SANS SERIF UPPERCASE CHARACTERS DISPENSER PEDESTRIAN RAMPS. 7358 S W DURHAM RD. ACCOMPANIED BY GRADE 2 BRAILLE. (SEE ITEM 4 BELOW) TOILET ACCESSORIESE. VERTICAL CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE SHALL NOT PORTLAND, OR 97224 4'-6" MIN. EXCEED 1/4 INCH. WHEN UP TO 1./2" CHANGES IN LEVEL DO OCCUR, THEY - b. CHARACTER SIZE. RAISED CHARACTERS SHALL BE A MIN. OF 5/8" 39"- 41" ' / SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2 EXCEPT THAT PROJECT TYPE: PHARMACY (15.9mm) AND A MAX. OF 2" (51mm) HIGH. GRAB BAR iGRAB BAR 1,, LEVEL CHANGES NOT EXCEEDING 1/4 INCH MAY BE VERTICAL, WHEN DEAL TYPE: NPR _ c. PICTORIAL SYMBOL SIGNS (PICTOGRAMS). PICTORIAL SYMBOL SIGNS 1I-0" �'`"� . • .,- _ \ 2 12" CHANGES IN LEVEL GREATER THAN 1/2 INCH ARE NECESSARY COMPLY WITH (PICTOGRAMS) SHALL BE ACCOMPANIED BY THE VERBAL DESCRIPTION -�- ' MAX. 3'-6" t° MIN' A117.1-2009) CS PROJECT NUMBER: 0106369 MIN. THE REQUIREMENTS FOR CURB RAMPS (PER 405 AND 406 OF ICC PLACED DIRECTLY BELOW THE PICTOGRAM. THE OUTSIDE DIMENSION OF THE MIN. ____7,�/ '-,� • PICTOGRAM FIELD SHALL BE A MIN. OF 6" (152mm) IN HEIGHT. ,»i -\--- v . ""\ ) _ � ..� a -s- F. WALKS SHALL BE PROVIDED WITH A LEVEL AREA CONSISTENT WITH mo!"' = - >, _ ± 10 - - - �- MANEUVERING CLEARANCES AT MANUAL SWING DOORS AND GATES (PER d. CHARACTER PLACEMENT. CHARACTERS AND BRAILLE SHALL BE IN - c� o_ y� ao ¢ r) a, �� (oma ion I I a' c�1-- 404.2.3.2 OF ICC A117.1-2009). HORIZONTAL FORMAT. BRAILLE SHALL BE PLACED A MIN. OF 318" I = i < m` •it © -1 I ±w� , I = < •• r•. _1 ARCHITECT OF RECORD DIRECTLY BELOW THE TACTILE CHARACTERS FLUSH LEFT OR CENTERED. IN cv "� - v \ ,.� - ;� G. ALL WALKS WITH CONTINUOUS GRADIENTS SHALL HAVE LEVEL AREAS OF AT WHEN TACTILE TEXT IS MULTI-LINED, ALL BRAILLE SHALL BE PLACED © ¢ `� '` © � '� © � Lr/ to LEAST 5 FEET IN LENGTH AT INTERVALS OF AT LEAST EVERY 200 FEET (PER TOGETHER BELOW ALL LINES OF TACTILE TEXT. \ \ \ < . - 405.2 OF ICC A117.1-2009) 4. BRAILLE. CONTRACTED GRADE 2 BRAILLE SHALL BE USED WHEREVER TABLE 404.2.3.2-MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS LAVATORY URINAL SANITARY NAPKIN „� z ¢ FLUSH VALVE 17"_18" ®CURB RAMPS BRAILLE IS REQUIRED IN OTHER PORTIONS OF THESE STANDARDS. DOTS ( 7 MIN ."-- - SHALL BE .09" - .1" IN EACH CELL WITH .241" - .3" SPACE BETWEEN ALL LAVATORIES TO DISPOSAL WOMEN S : ON WIDE SIDE / /CELLS, MEASURED CENTER TO CENTER FROM THEFIRST COLUMN OF DOTS IN TYPE CSF USE t�itANEUVERING CLEARANCES AT MANUAL SWINGING DOORS ONLY) EA. STALL 9"MAX - - OF STALL A. CURB RAMPS SHALL HAVE MAXIMUM SLOPE OF 1:12 WITH MAXIMUM CROSS RECEIVE ADA 'n SLOPE OF 1:48. THE CLEAR WIDTH SHALL BEA MINIMUM OF 36" WIDE. THE THE FIRST CELL TO THE FIRST COLUMN OF DOTS IN THE SECOND CELL. Parallel to Doorway COMPLIANT PIPE - `rFLARED SIDE SHALL HAVE A MAXIMUM SLOPE OF 1:10. DOTS SHALL BE RAISED .025" - .037" ABOVE THE BACKGROUND. BRAILLE Approach [lirectican Qoor Side Perpendicularto aorway (beyond latch unless noted) PROTECTION MAINTAIN 1-1/2" CLEAR BETWEEN ANY FIXTURE OR ACCESSORY AND GRAB BAR. 1251!!!;5: � DOTS SHALL BE DOMED OR ROUNDED. (PER 703.3.1 OF ICC A117.1-2009) B. THE MINIMUM LANDING AT THE TOP OF A CURB RAMP SHALL BE 36 WIDE. �� � �_,,1.� From front Pull 6`�Inches(152, mm) 18 inches(455 rnrr) - G Eng(neermg Atcniitecture 5. MOUNTING LOCATION & HEIGHT. WHERE PERMANENT IDENTIFICATION IS __. __.__.._...._... __ _._ _ _._..... _....._._ (PER FIG. 406. OFICC A117.1 200 NOTE: 7 9} PD and PROVIDED FOR ROOMS AND SPACES, SIGNS SHALL BE INSTALLED ON THE From front Push 48 inches(1220 Tram) • O Triches(0mrra)3 I PLUMBING FIXTURES G.C. TO INSPECT EXISTING PLUMBING FIXTURES -- -I FOR HANDICAP ACCESSIBILITY COMPLIANCE Professional Corporation WALL ADJACENT TO THE LATCH SIDE OF THE DOOR. WHERE THERE IS NO From hinge side. Pull 64 Inches(1:25 rrr) 366 inches(915 mm) I PER THE REQUIREMENTS OF THIS SHEET AND I 520 South Main Street Suite 2531 WALL SPACE ON THE LATCH SIDE, INCLUDING AT DOUBLE LEAF DOORS, at least as wide SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL, PREFERABLYANY OTHER JURISDICTIONAL REQUIREMENTS. Akron,OH 44311 From hinge side Pull 5 t I aches(13 0 r aCi} 42 inches(106a rrirn) 36 min l 71r, as curb ramp 330.572.2100 Fax:330.572.2102 ANY ITEMS THAT ARE NOT IN COMPLIANCE ■ � � ON THE RIGHT. TACTILE CHARACTERS SHALL BE LOCATED 48" MINIMUM _ From hinge side Push 42 inches(10 65€nm)'r 22 inches(560 mrst)344 ARE TO BE BROUGHT UP TO COMPLIANCE BY 915 ABOVE THE FINISHED FLOOR OR GROUND SURFACE, MEASURED FROM THE i THE G.C. BASELINE OF THE HIGHEST TACTILE CHARACTER. (PER 703.3.10 OF ICC From Latch side PIA 48 Inches(122:0 mm) 24 Inches(610 mm) - I _ - 1 A117.1-2009) From hitch side Push 42 inches(1065 mm) 24 inches(610 mr,) ?Ni- 6. SIGNS CONTAINING TACTILE CHARACTERS SHALL BE LOCATED SO THAT A smhos ctsaNen)fslascrand latch krost. (� CLEAR FLOOR SPACE 18" MIN. X 18" MIN. CENTERED ON THE TACTILEz.,&#6mclass(iSUzarig4chaser prowlet€. 16"-I&" I6"-IS" CONSULTANT' LETTERS IS PROVIDED BEYOND THE ARC OF THE DOOR SWING BETWEEN THE 1414112inches,(2.u5re�)beyondraid,stdos:r latch pro-Med 1, , .\,11.111 CLOSED POSITION AND 45 DEGREES OPEN POSITION (PER 703.3.11 OF ICC 46ordtuneode `� 1T - A117.1-2009) INTERNATIONAL DIRECTIONAL ARROW r� -� ill � Alli g kik SYMBOL OF WHERE NEEDED TO �^ IC:::::: in ACCESSIBILITY; PROVIDE DIRECTION z , s s PROFILE IN WHITE ON OF ACCESSIBLE PATH. - BLUE BACKGROUND. F. EACH GRADE LEVEL EXTERIOR EXIT DOOR SHALL BE M `r ()ACCESSIBLE PARKING FIG 406.7 IDENTIFIED BY A TACTILE EXIT WITH THE WORD "EXIT." EMIT A. ACCESSIBLE PARKING SPACES SHALL BE LOCATED ON THE SHORTEST ()DOORS G. EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE-LEVEL L.'� I - - - - - ACCESSIBLE ROUTE FROM PARKING TO AN ACCESSIBLE ENTRANCE. EXTERIOR EXIT BY MEANS OF A STAIRWAY OR RAMP SHALL CORRESPONDING BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE FOLLOWING TYPE II RESTROOM B. ACCESSIBLE PARKING SPACES SHALL HAVE A MINIMUM WIDTH OF 144" (PER A. LATCHES AND LOCKSETS: PROVIDE LEVER TYPE, PUSH-PULL OR PANIC TYPE WORDS AS APPROPRIATE: 1) "EXIT STAIRS DOWN" 2) "EXIT BRAILLE SIGN 502.2 OF ICC A117.1-2009) HARDWARE 34 INCHES TO 48 INCHES ABOVE FLOOR. RAMP UP" 3) "EXIT STAIR UP" 4) "EXIT RAMP UP" II 60" B. MAXIMUM FORCE TO OPERATE INTERIOR / NON-FIRE RATED DOORS SHALL BE H. EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE-LEVEL �� EXIT t3/4" II NOTES: C. WIDE ACCESS AISLES SHALL BE PROVIDED. TWO PARKING SPACES SHALL SLBS PRESSURE. COORDINATE FIRE DOORS OPENING FORCE WITH LOCAL 60 MIN. 60 MIN. BE PERMITTED TO SHARE A COMMON ACCESS AISLE- ACCESS AISLES SLOPES EXTERIOR EXIT BY MEANS OF AN EXIT ENCLOSURE OR AN �--�����•+ w. - SIGNS SHALL COMPLY WITH 703 OF ICC SHALL NOT EXCEED 1:48 IN ANY DIRECTION. CODES. EXIT PASSAGEWAY SHALL BE IDENTIFIED BY A TACTILE EXIT (a) (b) A117.1-2009. DEVELOPER' SIGN WITH THE WORDS "EXIT ROUTE." adult wall hung adult floor mounted water D. WHERE PARKING RESULTS IN VEHICLES OVER HANGING INTO WALKWAYS C. THRESHOLDS: THE FLOOR OR LANDING SHALL NOT BE MORE THAN 1/2 INCH n SIDEWALKS OR OTHER ACCESSIBLE ROUTES, THE OVERHANG SHALL NOT LOWER THAN THE THRESHOLD OF THE DOOR WAY. CHANGE IN LEVEL I. EACH EXIT ACCESS DOOR FROM AN INTERIOR ROOM OR AREA EMIT ROUTE water closet closet -FINISH AND CONTRAST. PICTOGRAMS AND ENCROACH ON THE REQUIRED CLEAR WIDTOF THE TRAVEL PATH. ..��•r THEIR HELD SHALL HAVE A NON-GLARE BETWEEN 1/4 INCH AND 1/2 INCH SHALL BE BEVELED WITH A SLOPE NO TO A CORRIDOR OR HALLWAY THAT IS REQUIRED TO HAVE A `s, and children's water closet FINISH- PICTOGRAMS SHALL CONTRAST WITH E. ACCESSIBLE PARKING SPACES AND ACCESS AISLES SHALL BE MEASURED TO GREATER THAN 1:2 (PER FIG 303.3 OF ICC A117.1-2009). VISUAL EXIT SIGN, SHALL BY IDENTIFIED BY A TACTILE EXIT THEIR FIELD WITH EITHER A LIGHT PICTOGRAM THE CENTERLINE OF THE PARKING STRIPE DESIGNATING THE SPACE. ACCESS SIGN WITH THE WORDS "EXIT ROUTE." ON A DARK FIELD ORA DARK PICTOGRAM ON D. LEVEL FLOOR OR LANDING: THERE SHALL BE A LEVEL SURFACE NOT PARKING SPACES SHALL BE OUTLINED IN BLUE PAINT; THE OUTLINED BLUE J. EACH EXIT DOOR THROUGH A HORIZONTAL EXIT SHALL BE g ALIGHT FIELD. STEEPER THAN 1:48 AND CLEAR AREA ON EACH SIDE OF AN EXIT DOOR. THE Figure 604.2 PAINT SHALL BE MARKED INSIDE THE SPACE'S STRIPING FOR ITS SIZE. LEVEL AREA SHALL BE AS SHOWN IN FIGURE 404.2.3.4 OF ICC A117.1-2009. IDENTIFIED BY A SIGN WITH THE WORDS "TO EXIT." Water closet location Fi Figure -TEXT DESCRIPTORS: PICTOGRAMS SHALL F. ACCESSIBLE PARKING SIGNS SHALL INCLUDE THE INTERNATIONAL SYMBOL FOR THE SPACE BETWEEN TWO CONSECUTIVE DOOR OPENING (VESTIBULE) SHALL g HAVE TEXT DESCRIPTORS LOCATED DIRECTLY PROVIDE 48 INCHES OF CLEAR SPACE FROM ANY OPENED DOOR INTO SUCH 604.3.1 size of clearance at BELOW THE PICTOGRAM FIELD. TEXT ACCESSIBILITY (ISA) COMPLYING WITH 703.6.3.1 OF ICC A117.1-2009). SIGNS SPACE. DESCRIPTORS SHALL COMPLY WITH 703.2, IDENTIFYING PARKING SPACES SHALL CONTAIN THE DESIGNATION "VAN ®PROTRUDING OBJECTS waterclosets. 703.3 AND 703.4 OF ICC A117.1-2009. ACCESSIBLE". SIGNS SHALL BE MOUNTED 60" MINIMUM ABOVE THE GROUND OR E. DOOR WIDTH & HEIGHT: 3 FEET WIDE AND 6 FEET 8 INCHES HIGH. CLEAR A. PROJECTIONS FROM WALLS WITH LEADING EDGE BETWEEN 27 INCHES AND 80 FLOOR SURFACE MEASURED TO THE BOTTOM OF THE SIGN (PER 502.7 OF ICC WIDTH: 32 INCHES TO THE WITH DOOR OPEN H DEG. OM 10 IN FROM THE INCHES ABOVE FLOOR MAY PROJECT 4 INCHES MAXIMUM. LEADING EDGE AT OR -SYMBOLS OF ACCESSIBILITY. SYMBOLS OF A117.1-2009) FACE OF THE DOOR TO THE OPPOSITE STOP. THE BOTTOM 10 INCHES OF ALL BELOW 27 INCHES MAY PROJECT ANY AMOUNT. FREE STANDING OBJECTS ACCESSIBILITY SHALL COMPLY WITH 703.7 OF DOORS EXCEPT AUTOMATIC AND SLIDING SHALL HAVE A SMOOTH MOUNTED ON POSTS OR PYLONS SHALL OVERHANG CIRCULATION PATHS 2" MAX. ICC A117.1-2009. G. A SIGN INDICATING THE PENALTY FOR ILLEGAL USE SHALL BE POSTED BELOW UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A ( THE ACCESSIBILITY PARKING SIGN. - WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS WHEN LOCATED 27" MIN. AND 80 MAX. ABOVE THE FLOOR OR GROUND SURFACE - LOCATION- WHERE A TACTILE IS PROVIDED, SEAL' CONDITION. 1/4" „ PER 307.3 OF ICC A117.1-2009} PROJECTIONS MAY NOT REDUCE MANEUVERING SIGNAGE SHOULD COMPLY WITH 303.4.2 OF ICC � D -4 2 1/2 SPACE, OR CLEAR WIDTH OF AN ACCESSIBLE ROUTE. BACKGROUND TO A117.1-2009 N, Qe, 1 j4" B. HEAD ROOM: 80 INCHES MINIMUM- 2„ STING 8E CONTOATEXT 9„ ( � ' '- - Pi 1/4„,,....- ti r� .� �' U MARK S. SALOPEK Cn .TOP OF COLOR TO BE ®ELECTRICAL SIGN SELECTED BY CVS SIGN OF '"`' AKRON OH H FIG. 303.3 PM' TACTILE CHARACTERS SHALL BE EMERGENCY A. ELECTRICAL RECEPTACLES (15, 20 AND 30 AMPS) SHALL BE AT LEAST 15 INCHES SANS SERIF AND SELECTED FROM • NO. NM • n ABOVE THE FLOOR. FONTS WHERE THE WIDTH OF THE XI z _ �j� -o UPPERCASE LETTER "0" IS 55% /\ -- 'O �; -, B. THE OPERATIONAL PORTION OF SWITCHES AND CONTROLS FOR LIGHTS, APPLIANCES, _ z MINIMUM AND 110% MAXIMUM OF THE c° CP ¢ ... r � COOLING, HEATING ANDSVENTILATING EQUIPMENT SHALL BE NOT LESS THAN 36" X ao HEIGHT OF THE UPPERCASE LETTER ` co if10961111:11). ' �o 2fre I I ` 9 NOR MORE THAN 48 ABOVE THE FLOOR ¢ "I. AND WHERE THE HEIGHT OF THE - �,\ (Q ¢ ' tt �� i UPPERCASE LETTER "I" IS 5 8" °'o" '''''""'''`� ! 18;?•*ixa � I GRADE 2 BRAILLE - I f ao 0 00 0 00 "o' o x O D ) o , C- FIRE ALARM INITIATING DEVICES SHALL BE 48 INCHES ABOVE THE FLOOR, GROUND EITHER CENTERED MINIMUM AND 2" MAXIMUM. I ¢ E--..� r ' ' ' OR SIDEWALK. FLUSH VALVE HEIGHT SHALL BE 48 MAX. I UPPERCASES ND R BE ALL in 2/2017 r OR JUSTIFIED LEFT ' SIGNAGE GRADE 2 BRAILLE 7.....- y r„ ill * UPPERCASE AND RAISED 1 j32" 3/8" M!N BELOW MINIMUM FROM SIGN SURFACE. BACKGROUND TO EITHER CENTERED - iVIS li i °SANITARY FACILITIES _ TACTILE BE CONTRASTING OR JUSTIFIED LEFT O z CHARACTERS- SEE j .-. -, „ .;,, -. .; o z 2010 ADA COLOR TO TEXT. 3/8" MIN BELOW o A. ACCESSIBLE COMPARTMENT DOORS SHALL BE SELF CLOSING. THE INSIDE AND I STANDARDS FOR COLOR TO BE TACTILE - REVISIONS: .....................: SELECTED BY CVS CHARACTERS. SEE 15 If hat)timerersYl Mar•pr4+ridad OUTSIDE OF THE COMPARTMENT DOOR SHALL BE EQUIPPED WITH A DOOR PULL BRAILLE a WF Arrp.o h Full Sitio I it Trap h.eu ns;:i• IMMEDIATELY BELOW THE LATCH. THE LATCH SHALL NOT REQUIRING THE USER TO „FINISHED SPECIFICATIONS. FINISHED M STANDARDS FOR 96 min 132 min 7,-. GRASP OR TWIST. '1FLOOR " FLOOR BRAILLE 2440 / 3350 / 0 I a-------- - = " SPECIFICATIONS. B. WATER CLOSET: THE HANDLE OR BUTTON IS TO BE LOCATED ON THE WIDE SIDE OF THE WATER CLOSET. (0) (b) ''=ti aRAMPS car FIG 502.2 van , �' C. URINALS: PROVIDE ALL WALL HUNG URINALS OR STALL TYPE WITH RIM ELEVATION WALL „ r 36,r I 106a { TO BE 17 INCHES MAXIMUM A.F.F. AND RIM PROJECTING 13-1/2" MINIMUM. ,/' 17"-25" / / 48 MIN. A. ANY PATH OF TRAVEL SHALL BE CONSIDERED A RAMP IF ITS SLOPE IS 5max 15 min 0 1 r t - - r D. LAVATORY: PROVIDE A CLEARANCE OF AT LEAST 29 INCHES FROM THE FLOOR TO 125 380 GREATER THAN 1:20 (1:12 MAXIMUM FOR RAMPS) o h THE BOTTOM OF THE APRON AND SINK RIM OR COUNTER SURFACE 34" AFF A B. RAMPS WITH A VERTICAL RISE GREATER THAN 6" SHALL HAVE HANDRAILS ON MAXIMUM, WITH KNEE CLEARANCE UNDER THE FRONT LIP EXTENDING A MINIMUM OF o,,, _ 30 INCHS WIDE TO 8 INCHES MINIMUM DEPTH AT THE TOP. PROVIDE FOR THE 1 - x r t BOTH SIDES- $c1 Wag* CLEARANCE AT LEAST 30 INCHES WIDE TO 9 INCHES ABOVE THE FLOOR AND 17 X �•� `� N kkrrrgeh Sufi Side "� ZIII U INCHES DEEP FROM THE FRONT OF THE LAVATORY. PROVIDE A CLEAR FLOOR < -•• �t I z SII C. THE TOP LANDINGS ON A RAMP MUST BE AT LEAST 60 INCHES IN DEPTH. o SPACE 30 INCHES X 48 INCHES (N FRONT 0 LAVATORY. THE CLEAR SPACE MAY _,,, re., .,.-'NE____ I - - to co EXTEND INTO KNEE AND TOE SPACE UNDERNEATH THE LAVATORY. INSULATE HOT z �;; „Ir _+ � o i� _ Try rn D. IFA DOOR SWINGS ONTO A TOP LANDING, THE MINIMUM LANDING DIMENSIONS 92 min" ._ r ---- El i SHALL MEET THE MANEUVERING CLEARANCES AT MANUAL SWING DOORS AND z _ r , WATER AND DRAIN PIPES UNDER LAVATORIES- NO SHARP OR ABRASIVE SURFACES m -_•� N ' 6 SAA ARE ALLOWED UNDER LAVATORIES. FAUCET CONTROLS ARE REQUIRED TO BE ( ll �/ _• GATES (PER FIG. 404.2.3.2 OF ICC A117.1-2009) 3 ; ; i 24 n OPERABLE WITH ONE HAND AND CANNOT REQUIRE GRASPING, PINCHING, OR f w o cn "g-' '' 610 TWISTING OF THE WRIST- THE FORCE NECESSARY TO OPERATE CONTROLS IS NOT - HIGH FORWARD REACH `¢-I z z E. THE BOTTOM LANDING SHALL BE NOT LESS THAN 72 INCHES DEEP ') , i56° *`- TO EXCEED 5 LB/F. LIMIT CJ Li) o F. INTERMEDIATE LANDINGS SHALL BE PROVIDED AT TURNS AND WHENEVER THE r- w ~a E. ACCESSORIES: WHERE TOWEL, SANITARY NAPKIN AND WASTE RECEPTACLES AND WALL w w w CHANGE IN LEVEL EXCEEDS 30 INCHES „ w DRAWING BY: 0 SIMILAR DISPENSING AND DISPOSAL FIXTURES ARE PROVIDED, AT LEAST ONE OF 48 MIN. ELEVATION z 0 �' PLAN -o EACH TYPE IS TO BE LOCATED WITH ALL OPERABLE PARTS, INCLUDING COIN SLOTS, X ¢ G. INTERMEDIATE LANDINGS ON STRAIGHT RAMPS SHALL HAVE A DEPTH OF NOT AWITHIN 40 INCHES FROM THE FLOOR- LESS THAN 60". INTERMEDIATE LANDINGS ON RAMPS THAT TURN GREATER .�. `54 {1370)itc; rispro ci �/ DATE: June 6, 2017 "o AA, _��_ DRINKING FOUNTAIN THAN 30 DEGREES SHALL BE NOT LESS THAN 72' IN DEPTH. a_ -MOUNT MIRRORS WITH THE REFLECTIVE EDGE NOT MORE THAN 40 INCHES ABOVE , ,_ - z H. RAMPS SHALL BE NOT LESS THAN 36" WIDE. •tfr2sxarar,eiaaopil THE FLOOR. `� I JOB NUMBER: 2016285.50 .2 ----- ..c ••a8 m {tit)ri i #t nbor aex9octsrwca ,� AI ¢ " �"� >�` I , 10" „ I. HANDRAILS SHALL BE PLACED ON EACH SIDE OF EACH RAMP AND SHALL BE -LOCATE TOILET TISSUE DISPENSERS ON THE WALL WITHIN 7 -9 FROM THE Ali _ - 24 CONTINUOUS THE FULL LENGTH OF THE RAMP. HANDRAILS SHALL BE 34 TO TITLE: '. v lei Hinge Approach,Push Side I!i}LaathApproach,Pull&do FRONT EDGE OF THE TOILET SEAT BETWEEN 15" AND 48" FROM THE FLOOR TO •( �'�, - r7 MAX. 30" 30" MAX. 38 INCHES ABOVE THE RAMP SURFACE AND EXTEND A MINIMUM OF 1 FOOT o u, r ,,/,C^ _,It BEYOND THE TOP AND BOTTOM OF THE RAMP. N z THE PAPER OUTLET. ,/�-�_ 0 ; ; G. THE STRUCTURAL STRENGTH OF GRAB BARS, FASTENERS, AND MOUNTING - ACCESSIBLE CODE '� I Lc) I I :s DEVICES SHALL MEET THE BUILDING CODE. 1. HANDRAILS SHALL PROVIDE EDGE PROTECTION FOR RAMPS: N ' 48" MIN. a. RAMPS SHALL HAVE EDGE PROTECTION (PER 405.9 OF ICC "I COMPLIANCE INFORMATION r; °° 1' f - i ()SALES/ SELF SERVICE AREAS etill A117.1-2009 ON EACH SIDE OF RAMP RUNS AND EACH r' SHEET NUMBER: A. FOOD SERVICE AREAS SHOULD BE INSTALLED TO ALLOW AT LIST 50% OF THE ¢ x SIDE OF RAMP LANDINGS. -48, 1122.0) SELF SERVICE SHELVES TO BE WITHIN THE REACH RANGES OF 15" LOW AND 48" HIGH X SHALL BE LESS THAN OR EQUAL TO 25 INCHES- - ¢ 3 `� 1fclowsr is PER 2010 STANDARDS PER, SECTION 904.5.1. Z SHALL BE GREATER THAN OR EQUAL TO X. WHEN I. 405.9.1 THE FLOOR OR GROUND SURFACE SHALL EXTEND 12" 0 o o X IS LESS THAN 20 INCHES- THEN Y SHALL BE 48" oo f �• - BEYOND THE INSIDE FACE OF THE HANDRAIL0 t, 4 '" -- MAXIMUM. WHEN X IS 20 TO 25 INCHES, THEN Y W ll. I W l ii- 405.9.2 A CURB OR BARRIER SHALL BE PROVIDED THAT , 0 (9) - hApproach.PushMae SHALL BE 44 INCHES MAXIMUM. �� _ PREVENTS THE PASSAGE OF A 4" DIAMETER SPHERE WHERE a) nL ANY PORTION OF THE SPHERE IS WITHIN 4" OF THE MAXIMUM FORWARD REACH FINISHED FLOOR OR GROUND II II FIG.434.2,3_2 OVER AN OBSTRUCTION SIDE REACH LIMIT COMMENTS: o, NIANEUVERING CLEARANCE AT MANUAL SWINGING DOORS J. SURFACES OF RAMPS SHALL BE SUP-RESISTANT a W APCVS Health STORE NUMBER: 48140 • /‘, CORAM, INC. \/"., ICODE I � 0VATIONPORTLAND, OR 97224 PROJECT TYPE: PHARMACY (BASED ON 2014 OREGON BUILDING CODES) OFFICE DEAL TYPE NPR 1. USE AND OCCUPANCY CLASSIFICATION (302.0) CS PROJECT NUMBER: 0106369 • BUSINESS GROUP (0) L . ,_ STORAGE (S2) ` , OFFICE OFFICEARCHITECT OF RECORD 2. CONSTRUCTION TYPE: TYPE III-B CONSTRUCTION (SPRINKLERED) - INFUSION \ OFFICE 3. BUILDING HEIGHT (503.0) ;.1_...___._ Allowable Height (story/feet) 4 STORY/ 55'-0" _..... „-_.______ ......__ Actual Height (stories/feet) 1 STORY ,- - mm I CORR. i . i. I_ _ ..---.__..._ _ _ i CPD Engineering and Architecture 4. BUILDING AREA (503.0) F Allowable Building Area per floor 76,000 SF 1 Professional Corporation 45,036 SF ��� Building Area `',% i INFUSION / 520 South Main Street,Suite 2531 Tenant Lease Area 12,417 SF CONFERENCE Akron,OH 44311 Area of Work 1,669 SF AlkAlk ADJACENT TENANT SPACE 2 ; CONFERENCE I 330-5722100 ax: 3305722102 r _ ____ A-1 .1 A-1 .4 _ 3 5. FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS �-� CORK. (Table truct0ul):rai frame (including columns, girders, trusses): 0 Hr(s) Alir-Ak 1 ,per CONSULTANT' ' B. Bearing walls (interior & exterior) 0/2 Hr(s) A-1 .2 A-1 .5 ...��T I OPEN OFFICE C. Nonbearing walls & partitions (interior & exterior): 0 _Hr(s) , [�l; .... D. Floor construction (including supporting beams & joists): 0 Hr(s) {'71 I ( 9 PP g 1 ) { ) as ` 3 — STORAGE TEL E. Roof construction (including supporting beams & joists): 0 Hr(s) I L\-/ [_.!r 1.' ' ..4.? A-1 .3 A-1 .6 ...60:1114# Aii* I' _ 7. FIRE PROTECTION SYSTEMS, CORAM HEALTHCARE SUITE ONLY ♦ A. Sprinkler System (903.2.7): Required Yes Provided Yes B. Standpipe System (905): Required No Provided No * / I 1 4C. Fire & Smoke Detection (907): Required Yes Provided Yes 410' L ik .. D. Fire Alarm (907.2.2): Required No Provided No461'1 E. Smoke Vents (910): Required No Provided No '\' / AREA OF V Y ORK v F. Portable Fire Extinguisher (906): Required Yes Provided Yes \ / = / 8. DESIGN OCCUPANT LOAD (1004.1) OFFICE Business Areas (100 sf/occ.) 10,317 sf / 104 occ. I ,77 I—I Ii �` �- t Storage Areas (500 sf/occ.) 2,099.6 sf / 5 occ. SECURE STORAGE i l I i Q� �1 DEVELOPER: ��'' i + TOTAL OCCUPANT LOAD 109 occ. 70�, �,�0 r 9. EXITS WALK-IN COOLER �0 A. Doors (1005): > CORR. ---'7'. Required 109 x 0.20" = 21.80" 0 1 ct. Provided 136" d 111 CIRC. -- B. Min. Door Width (1008.1.1): 32" Clear \ 1 C. Number of Exits (1021.1) Z From each Floor No. Required No. Providedt , Ground Floor 2 3 �� ij , % D. Travel Distance (1016.1) O _ i E\ I " 1 Allowable 300 -0 L.F. i - - / Provided 102'-11" L.F. L r 1 I OFFICE SEAL: ti��D A�c� F. Min. Corridor Width (1018.2): 44" -JJ G. Max. Dead End Corridor Distance (1018.4.2): 50'-0" OPEN OFFICE �G' f�' SHIPPING - U MARK SALOPEK 51 0. NOTE: RE: 1/A-1.0 FOR ADDITIONAL INFORMATION. li �- AKRON', OH ,��, 0 - -- ° NO. G036 • J1, BREAK ,' �� ,� >ri 1i. Cjj AA a 06/12/2017 ,- . / REVISIONS: a 2 U S L Q C U N.C U O cl \C O C WAREHOUSE U Cn D C 0 U ,- 0_,O, U DRAWING BY: 0 DATE: June 6, 2017 0 1-- \ a_ JOB NUMBER: 2016285.50 Q / 0 0 - , .' TITLE: OVERALL/EXITING PLAN n i O cv u7 oo _ SHEET NUMBER: TO 1 OVEALL/EX TNG PLA \ _ . 0 oN CO / o A--1 .O SCALE: 1/8"=1'-0" \ ‹.. 0 c m „ �- N COMMENTS: ii II E a a) � C {!5 0 ,� LEGE\D NOTES 3Y SYM3OL ® GE\ E�AL NOTES _.. __WALLS/ITEMS TO BE REMOVED 1. REMOVE EXISTING PASS-THROUGHS. PREPARE A. DEMOLITION PLAN REFLECTS INFORMATION WALL TO RECEIVE NEW PASS-THROUGHS IN NEW GATHERED FROM EXISTING DRAWINGS & FIELD WORK. INSPECTION. ALL CONTRACTORS SHALL VERIFY WALLS/ITEMS TO REMAIN 2. REMOVE EXISTING VISION PANEL. PREPARE ACCURACY OF INFORMATION & INCLUDE ALL IP CVS OPENING TO RECEIVE NEW VISION PANEL IN NEW DEMOLITION IN THEIR BID. ALL CONTRACTORS WORK. RE: A-1.4. SHALL REPORT ANY DISCREPANCIES TO GPD 3. REMOVE EXISTING DOOR, FRAME AND HARDWARE. GROUP. 4. REMOVE EXISTING SINK, CAP PLUMBING LINES, B. EXISTING DOORS AND FRAMES IN EXISTING Health RE: PLUMBING DWGS. PREPARE WALL TO RECEIVE WALLS TO BE REMOVED AND SHALL BE NEW FINISHES. SALVAGED FOR POSSIBLE REUSE. IF NOT TO BE 5. SHADED AREA: REMOVE EXISTING FLOOR FINISH USED, THEY ARE TO BE OFFERED TO THE AND PREP. EXISTING FLOOR FOR INSTALLATION BUILDING OWNER PRIOR TO PROPER DISPOSAL. OF NEW WELDED SHEET VINYL FLOORING C. REMOVE EXISTING WALL FINISHES (INCLUDING ACCORDING TO MANUFACTURER'S WALLCOVERING), FLOOR FINISHES, AND BASF IN STORE NUMBER: 48140 RECOMMENDATIONS. RE: A-1.4. AREAS TO RECEIVE NEW WORK. PATCH & • 6. LOCATION OF NPR SUITE IN NEW WORK. RE: PREPARE WALLS AND FLOORS AS REQUIRED TO CORAM, INC. A-1.4 RECEIVE NEW FINISH. 7358 S W DURHAM RD. 7. REMOVE EXISTING TRANSFER GRILLE, PREPARE D. SALVAGE ALL EXISTING LIGHT FIXTURES, CEILING WALL TO RECEIVE NEW FINISHES IN NEW WORK. MOUNTED EQUIPMENT, DIFFUSERS, AND EXIT PORTLAND, OR 97224 RE: A-1.4 AND MECHANICAL. LIGHTS FOR POTENTIAL RE-USE IN NEW PROJECT TYPE PHARMACY 8. REMOVE EXISTING TPN BENCH, PLASTIC CURTAIN CONSTRUCTION. OFFER UNUSED FIXTURES TO & SUPPORT FRAMEWORK. BUILDING OWNER PRIOR TO PROPER DISPOSAL. DEAL TYPE: NPR 9. REMOVE EXISTING WALK-IN COOLER IN IT'S E. PROTECT ALL EXISTING WINDOW TREATMENT AT ENTIRETY (WALLS, DOORS, "ROOF", SHELVING, EXTERIOR WINDOWS DURING CONSTRUCTION. CS PROJECT NUMBER: 0106369 LIGHTING, FTC.} F. PATCH AND REPAIR EXISTING CONSTRUCTION • 10. EXISTING FLOOR FINISH TO REMAIN THIS AREA. DUE TO THE RELOCATION OR ADDITION OF NEW 11. REMOVE LOCKSET, PREPARE DOOR TO RECEIVE FIXTURES, EQUIPMENT AND/OR NEW ARCHITECT OF RECORD BLANK PLATE IN NEW WORK, RE: DOOR CONSTRUCTION. SCHEDULE NOTES. 12. SHADED AREA: FINAL FLOOR FINISH TO MATCH EXISTING SECURE STORAGE. SECURE STORAGE EXISTING FLOOR FINISH ASSUMED TO BE WELDED SHEET VINYL. CONTRACTOR TO VERIFY FLOOR FINISH IN EXISTING SECURE STORAGE AND NOTIFY AOR IF EXISTING FLOOR FINISH IS NOT ._ SHEET VINYL. GPD Engineering and Architecture Professional Corporation 520 South Main Street,Suite 2531 Akron,OH 44311 330.572.2100 Fax: 330.572.2102 CONSULTANT: 3 S 4 ADJACENT TENANT SPA E f = y ' � � f I I DEVELOPER. 1 No.., Q 0 LL`-_1I t�.._ i \�\ IMPOUNDING ANTE ROOM I ':.W .. [101 I f _ ,, fl I U 0 i 1 I, H 0 — SEAL: �� Rc, © Et _ ��` [I ti��� �� \N. \o; a C_7 tiAi K S. 5:1T,Qi'1 lC tt1 a \�. - - - - v AhRO\, OH H ci ID . ��� PREP ROOM • NO. G038 • © 102 , I --- T 7 7-1t,-> J'� '� '�' 0 1 L I II \1 L C 1 01V ic\vs. Q CO 17c �N ��,� ` cn .v = — 0 0 \� 0 P 0 REVISIONS: q a © ... � �.,� — — — I' COMP U DING 1E 100 0 \�/i W I Q SECURE STOR•GE — — 0 I e ,n \ O H L_ a 0 0 O © WALK-IN COOLER cr CORR. — — — - — - I 0 Z _ © i (� ' � I I I CC II L 1 ......._- I o I4 —...— — �` /��,I I E _ E 1 - - DRAWING BY: .0 C �\ 5 -9 %4p DATE: June 6, 2017 0 u7 JOB NUMBER: 2016285.50 Q -t L _ 0 I ' __ . [31 — -1- TITLE:. •. . . . cNi Q � I DEVOL TON FLOOR PLAN i N u7 00 SHEET NUMBER: � -c co OT r0 _c 0 04 1 A cr) U] ,.. . ,t,CD -0 ( i \ ENOL TION PLAN E i.:, r— COMMENTS: u n A-1 .1 SCALE: 1/4" = 1 -0 �\ • D 0 C.. LEGEND NOTES BY SYMBOL ® GENERAL NOTES 1. REMOVE EXISTING 2X2 OR 2X4 SUSPENDED A. DEMOLITION PLAN REFLECTS INFORMATION 1c, I EXISTING LIGHT FIXTURE TO ACOUSTICAL CEILING SYSTEM. GATHERED FROM EXISTING DRAWINGS & FIELD IBE REMOVED. 2. EXISTING 2X2 SUSPENDED ACOUSTICAL CEILING INSPECTION. ALL CONTRACTORS SHALL VERIFY ! SYSTEM TO REMAIN. LIGHT FIXTURES TO BE ACCURACY OF INFORMATION & INCLUDE ALL IP CVS REMOVED AS SHOWN. PROTECT CEILING SYSTEM DEMOLITION IN THEIR BID. ALL CONTRACTORS DURING CONSTRUCTION, CLEAN AND REPAIR AS SHALL REPORT ANY DISCREPANCIES TO GPD EXISTING LIGHT FIXTURE TO REQUIRED. GROUP. N\`2�..' �1 BE REMOVED. SALVAGE FOR 3. LOCATION OF NPR IN NEW WORK. B. EXISTING DOORS AND FRAMES IN EXISTING Health REINSTALLATION IN NEW 4. +/- 13-4" MIN. AFF TO BTM OF EXISTING ROOF WALLS TO BE REMOVED AND SHALL BE ',- WORK STRUCTURE. FIELD VERIFY AND COORDINATE WITH SALVAGED FOR POSSIBLE REUSE. IF NOT TO BE NEW MODULAR NPR MECHANICAL CONNECTIONS. USED, THEY ARE TO BE OFFERED TO THE 5. REFER TO FIRE PROTECTION DRAWING, TYPICAL BUILDING OWNER PRIOR TO PROPER DISPOSAL. `' F�- -'', C. REMOVE EXISTING WALL FINISHES (INCLUDING � x` i I EXISTING FFU TO BE WALLCOVERING), FLOOR FINISHES, AND BASE IN STORE NUMBER: 48140 I 4' \I REMOVED. AREAS TO RECEIVE NEW WORK. PATCH & • PREPARE WALLS AND FLOORS AS REQUIRED TO CORAM, INC. — CEILING GRID TO BE RECEIVE NEW FINISH. 7358 S W DURHAM RD. REMOVED. D. SALVAGE ALL EXISTING LIGHT FIXTURES, CEILING MOUNTED EQUIPMENT, DIFFUSERS, AND EXIT PORTLAND, OR 97224 CEILING GRID TO REMAIN. LIGHTS FOR POTENTIAL RE-USE IN NEW PROJECT TYPE: PHARMACY CONSTRUCTION. OFFER UNUSED FIXTURES TO BUILDING OWNER PRIOR TO PROPER DISPOSAL. DEAL TYPE: TPR E. PROTECT ALL EXISTING WINDOW TREATMENT AT EXTERIOR WINDOWS DURING CONSTRUCTION. CS PROJECT NUMBER: 0106369 F. PATCH AND REPAIR EXISTING CONSTRUCTION ' DUE TO THE RELOCATION OR ADDITION OF NEW FIXTURES, EQUIPMENT AND/OR NEW CONSTRUCTION. ARCHITECT OF RECORD ommi GPD Engineering and Architecture Professional Corporation 520 South Main Street,Suite 2531 Akron,01-1 44311 330.572.2100 Fax:330.572.2102 III © 40 4 CONSULTANT: S ADJACENT TENANT SPACE DEVELOPER: / - I I I I ! 1 I I I I I I I I I I ! I I ! I I 1 I I I I I a I I I I I I ! I I 1 -1 ' I \\ ill ` �~1 I / I, \x� it i'1 �, 1 -----I-- -- ---�- -> I- T ! --7 MPO{1NDIf�G A t-T€-RON • I I \ / I I 101 ,__. I 1 1 / I 1 I 'I — I/ 1 , I \x' I 1 1 J IL J L _ )♦ \ I I �/ \\I '/ I SIC? I I I / \ / \ I ,' I /' I LW SEA L L `, ,i' \ I 1 Y I 1 7 7 T ID ...... .. , ., _ r -- / 1 \ 1 1 ' / ~i11/1Tfi S. S:11d)Plas', \ -.... / \ i lill � 0., ,,_ I I /f 0 // Zi__7\J PREP 1 ROOM i // / AKI O\, OH o \ j i 1/ / \\ I /' /r / / 1 rte] \ 9\6' i\ i /' r F 1 F ----,, ........6)..: '‘„?[ •., 1-- --F Y. 1 1---- / / / • NO. Goa6 • 1---- *----� F -- tIy 1 ,1 (-1 di 1 C Oily , tv iiib ¢_ \ �\\ 1 I ` li/ \`� / l� I x I J • \ 1 1 1 / 1 O Lr 7� ra �� fi i �'_ __-.�_._ __.._... . r----� 1 T \`,' r rj ', / \ 06/12/2017 �\ _ 1 1 1 I I i \ / / \ \ `0 i�\ ,� i roti I I I r r r---- ----7 L_— �, W 1 / �i `i I i x I I I I F�_1� / \ /I / / �' 1 -- . '' rL�r _ _ _ = o 1 FL ' I 'I: REVISIONS: : / 36; �\ ! 1 . .' 1 -- _� L.. r 1 i •.\ ! ll', ; 1\\ Gx PO I G �S� // 11 �� Uf9DlJ \ 1 1 ` �'� 1 j _ A 1 1 x I �) 1 I I i 40 SECURE STOR i E • I I 1 i�� I —�� / ---*----J I \ : \\,___,/, C E I „„ I �'� I I I 0 j 1 \ i I 1 \ i 1 o I 0 1 I x I 1 x 1 Q 1 1 x 1 i j 1,' `\ 1 I \\I o I I N. / / 1 \\\ //' WALK-IN COOLER I // +�� --F---� ,\` I ---- h,`\ i i --- '�.,`\ I — 1 o RRA\\ I / I \\ ,' I ----1----1--'.--- _ 1 _ — — I 1 1 I (411 _, \ I I , \I y\ it 71 4�\ sr71 1 y\ I ire 7\ ire i 1 I x I I x I I k I I x 1 . i ) Ei_ T 1▪:71 I - __ --- a _. C I 1p L L—s Hi i EH -di I, - -L -A .... . E r ♦ '.... , �i i �' i DRAWING BY: i 1 J .� I r I a_ � I 1 DATE: June 6, 2017 ' N. ___ r, JOB NUMBER: 2016285.50 D J �� 0 — \1 I �/ — 7-1----- TITLE: DEMOLITION REFLECTED CEILING PLAN N. di SHEET NUMBER: I 1 A .. . , , • 2 T ° Oi L 4 (' ThDEMOLITION CEILING PLAN COMMENTS: O !I II 1= C A---1 .2 SCALE: 1/4" = 1'—O" U7 01 = d li i NOTES 3Y SYN 30L 1. REMOVE EXISTING RTU. REMOVAL OF EXISTING RTU BY MECHANICAL CONTRACTOR. RE: MECHANICAL. PREPARE OPENING TO BE CAPPED IN NEW WORK. ,CVS 2. ROOF PENETRATION, COORDINATE WITH MECHANICAL. 3. OUTLINE OF COMPUNDING SUITE. 4. OUTLINE OF RTU IN NEW WORK Health STORE NUMBER: 48140 CORAM, INC. 7358 S W DURHAM RD. PORTLAND, OR 97224 PROJECT TYPE: PHARMACY DEAL TYPE: NPR CS PROJECT NUMBER: 0106369 ARCHITECT OF RECORD Alisomem A. GPD Engineering and Architecture Professional Corporation 520 South Main Street,Suite 2531 Akron,OH 44311 330.572.2100 Fax: 330.572.210? CONSULTANT. DEVELOPER: I O 1 \ r -1 , , 1, o r-I --, 4 I\ \ I arw_ e 41 A _ _. _ _ _ o —1 I I r 7 -1- 7- 71 Lk_z_z__._1 1O I SEAL,\ 1 C 4\IrAU�ESv.015A, O HPErF O o © I • NO. 6036 • \ � � � . N I irSti i iiib � 1 T © 06/12/2017 z) 1— I vI (//� - I I REVISIONS: 41U IE U Q I ci I I U U 0 C O U , _1 7 — — — — C O U cc o O U H cr0 DRAWING BY: DATE: June 6, 2017 a CD \ JOB NUMBER: 2016285.50 Lo N o TITLE: DENOLIT O ROOF PLAN r i Q N1-1) 00 5 SHEET NUMBER: CN C co O 7„s- A 4 C o N (-fl y / \....3 -E � 11 1 DEAIOL T ON ROOF PLA \ ECOMMENTS: A-1 .3 SCALE: 1/4” = 1'—O" \`�� ' v o I OTES 3Y SYMBOL ® GENRAL \ OTES A. PROVIDE SURFACE MOUNTED FIRE EXTINGUISHERS 1. PREPARE OPENING & INSTALL NEW CART AND TRAY RECOMMENDATIONS. INSTALL NEW WELDED SHEET VINYL 34. NEW REACH-IN COOLER. AS REQUIRED BY LOCAL CODES. IP CVS PASS-THROUGHS PROVIDED BY OWNER. PROVIDE FRP PRIOR TO ARRIVAL AND INSTALLATION OF NPR. WELDED 35. ACCESS DOOR, RE: 12/A-6.1. B. PROVIDE FINISHED GWB AND INSULATION AT ALL CLOSURE TRIM AT PASS-THROUGH PERIMETER EDGES; SHEET VINYL COVE BASE TO BE INSTALLED DURING 36. INFILL WALL AREA DAMAGED OR CREATED FROM REMOVAL PARTITIONS AS REQUIRED. SEAL AIRTIGHT. INSTALLATION OF NPR. OF TPN BENCH, PLASTIC CURTAIN AND SUPPORT C. ALL OUTLETS AT WET LOCATIONS TO BE G.F.C.I. AS 2. PROVIDE NEW VISION PANELS WITH STAINLESS STEEL FRAMEWORK. MATCH EXISTING CLEAN ROOM CONSTRUCTION PER GOVERNING CODES. RE: MEP. Health FRAME AND GLASS FLUSH WITH INTERIOR WALL SURFACES. 16.1. ARMSTRONG, MEDINTECH, GRAYED BLUE MID #H5329. AND INFILL FLUSH & SMOOTH WITH ADJACENT WALL D. IF EXISTING OUTLET OCCURS WITHING 24" OF SIZE TO MATCH EXISTING OPENING. RE: DETAILS A-7.1. 16.2.ARMSTRONG, MEDINTECH, OATMEAL #84129. FINISHES. PROVIDE TRIM AT ALL JOINTS AND EDGES OF WHERE NEW OUTLET IS INDICATED EXISTING 3. NOT USED. INFILL AREA TO MATCH EXISTING TRIM. LOCATION IS TO REMAIN. REPLACE EXISTING PLATE 4. INFILL WALL OPENINGS & PATCH DAMAGED AREAS LEFT 17. LINE OF DEMARCATION FOR SHEET VINYL FLOOR. 37. BOOTIE BUTLER. AND DEVICE WITH NEW. RE: MEP. FROM REMOVAL OF RELIEF GRILLES TO MATCH AND BLEND 18. FLOOR-SUPPORTED HOOD, BSC 404E. PROVIDED BY 38. NEW SHEET VINYL FLOORING TO MATCH EXISTING E. AT LOCATIONS WERE NO NEW ELECTRICAL WORK IS SMOOTH & FLUSH WITH ADJACENT WALL SURFACES. OTHERS, INSTALLED BY G.C. ADJACENT, THIS AREA. HEAT WELD TO CREATE SEAMLESS SHOWN, EXISTING ELECTRICAL LOCATIONS ARE TO PROVIDE FINISHES TO MATCH EXISTING. PROVIDE FRP TRIM 19. SINK & EYEWASH. SEE MECHANICAL DRAWINGS. TRANSITION. REMAIN. REPLACE EXISTING DEVICES AND PLATES STORE NUMBER: 48140 AT ALL JOINTS IN FRP WALL FINISHES. 20. NOT USED. 39. LINE OF TRANSITION BETWEEN NEW AND EXISTING FINISHES. TO MATCH EXISTING. RE: MEP. CORAM, INC. 5. NOT USED. 21. NOT USED. 40. ALIGN NEW WALL WITH EXISTING VISION PANEL OPENING. F. ALL RECEPTACLE DEVICES AND FACE PLATES TO 6. PROVIDE METAL STUD AND GYP. BD. CHASES FOR DUCT 22. STAINLESS STEEL SHELF 24"X36"X72". MATCH EXISTING. RE: MEP. 7358 S W DURHAM RD. DROP AND LOW WALL RETURN AIR GRILLE. COORDINATE 23. INSTALL NEW ACCESSIBLE ROOM IDENTIFICATION SIGN TO G. INSTALL MOISTURE RESISTANT BACKING BOARD AS PORTLAND, OR 97224 WORK WITH MECHANICAL CONTRACTOR. PROVIDE FRP MATCH EXISTING THROUGHOUT SUITE. MOUNT AT 4'-0" SPECIFIED AT ALL WET WALL LOCATIONS SUCH AS FINISH AND VINYL WALL BASES TO MATCH EXISTING. AFF TO BOTTOM OF SIGN. TOILETS, JANITOR'S CLOSETS, ETC. PROJECT TYPE: PHARMACY PROVIDE FRP TRIM AT ALL JOINTS iN FRP WALL FINISHES. 24. APPLY 3 COATS OF EACH FLOOR SEALANT PER H. PROVIDE BUILDING STANDARD WINDOW TREATMENT DEAL TYPE: NPR RE: MECHANICAL FOR DUCT SIZES. RE: 1, 2 & 3 ON MANUFACTURER'S RECOMMENDATIONS: SUPER GARD, CLEAR IN ALL EXTERIOR WINDOWS WHERE DAMAGED OR A-7.1. & DE-FENCE, CLEAR. (TENANT PROVIDED, CONTRACTOR MISSING AS REQUIRED. 7. HOOD, RE: MECHANICAL.. INSTALLED) J. ASCERTAIN THE EXTENT OF WORK NECESSARY TO CS PROJECT NUMBER: 0106369 8. FFU SPEED CONTROLLER, RE: MECHANICAL. 9. NOT USED. 25. STAINLESS STEEL CART 24"X36"X36". NOT ONLY ACHIEVE THE AESTHETIC INTENT, BUT ' 10. PROVIDE MODULAR WALL PANEL VERTICAL JOINT COVERS, 26. BAXTER REPEATER PUMP ON STAND. ALSO TO COMPLY WITH GOVERNING CODES & WIDTH TO COVER ALL VERTICAL SEAMS. RE: 6/A-7.1. 27. 55 GAL BRUTE WASTE CONTAINER. REGULATIONS, WHICH MAY REQUIRE ADDITIONAL ARCHITECT OF RECORD 11. REPAIR AND REPLACE ANY DAMAGED OR CUT AREAS OF 28. REFRIGERATOR (HAZARDOUS). WORK AND/OR EQUIPMENT. i VINYL FLOORING AND COVE BASE. WELD SEAL PATCHED 29. STAINLESS STEEL BENCH 18"X38"X18". K. ORDER ALL PARTS NECESSARY FOR INSTALLATION AREAS TO EXISTING ADJACENT VINYL FLOORING.. 30. MOP HOLDER OF FIXTURES SPECIFIED, U.O.N. 12. NOT USED. 31. STAINLESS STEEL SHELF 18"X48"X72". L. PROVIDE COORDINATING MECHANICAL, ELECTRICAL, A 13. NOT USED. 32. SUMP PUMP, RE: PLUMBING AND PLUMBING WORK REQUIRED FOR PROPER 14. NOT USED. 33. FRAME PREVIOUS DOOR OPENING TO ACCEPT NEW OWNER FUNCTION OF ALL FIXTURES AND EQUIPMENT, RE: 15. MODULAR NEGATIVE PRESSURE ROOM. RE: MEP DRAWINGS PROVIDED CART AND TRAY PASS-THROUGHS. ON PREP MEP. FOR ASSOCIATED CONNECTIONS. ROOM SIDE, PROVIDE FRP WALL FINISH AND FRP CLOSURE M. CLEAN AND PREPARE SLAB TO ACCEPT FINISHES. 16. MODULAR NEGATIVE PRESSURE ROOM FLOORING: PREP. TRIM. AT PASS-THROUGH PERIMETER EDGES, SEAL G.C. TO CONFIRM AND REPORT MOISTURE CONTENT EXISTING FLOOR FOR INSTALLATION OF NEW WELDED SHEET AIRTIGHT. FINISHES ON SECURE STORAGE SIDE TO MATCH TO ARCHITECT PRIOR TO FINISH WORK. GPD Engineering and Architecture VINYL FLOORING ACCORDING TO MANUFACTURER'S EXISTING. N. PROVIDE DETECTION SYSTEM, EMERGENCY LIGHTING Professional Corporation AND EXIT SIGNS AS REQUIRED BY GOVERNING CODES, RULES, AND REGULATIONS. RE: MEP. 520 South Main streoSuite 43,OH 443111 Akronn 0. ALL WALL OPENINGS TO ALIGN WITH PLASCORE 330.572.2100 Fax: 330.572.2102 WORK TO BE FIELD COORDINATED. P. PROVIDE NEW WINDOW TREATMENTS AT ALL EXISTING WINDOWS. CONSULTANT: 0 II II 4 DEVELOPER: Alk a A-7.1 A-7.1 SIM SIM - N - 0 Nil ' imi IN 2'-5 1/ " 31 _ ,� �.... -J .;. ..... , co fri al 5'-8" 0 `,®PR ANTI ROOM (01) ® 1 O •.MPOUNDING ANTE ROOM I � A-s. Co-j � O a101 it ._4 SEAL�'g ® 00 }1 ti �D ARC 2 \ 9541 0 ' OPP ® ti� fj, O ® \' \ \ I -1 C) MARK S. S.1LOPEK Com`' 22 /Pg • 7 4) cn AKRON OH -a ! ! COO 6036 • 0 /-114h II 0 • \ _ '. i N ak TD_ Cr . cc, PREP ROOM i ■Ili \, '111i-- NEG. PRESSURE 0 0 102 III_1 111111111111111 1'_3" J ,y � 105 , / ,1� - q��. ... eli0161'12T�l 25 r IC ,' A-s. � �I 7c N ,� rill Q 06/12/2017 �� / ./ V fI 0 \ ' . / 0 ii 1 18 27 9 -11" _ REVISIONS: 0/__,5 ` ` 6> _ 37 1 Goo O L COMPOUNDING IF 0 Pill i 1r1 Iilio 0 100 0 C l I ® H ® H SECURE STOR GE l I1c I In - , c0 a 2 _SECURETORAGE VESTIBULE A-7.1 104 SIMi 0 00 WALK-IN COOLER Q OQ 1,-3" 15 -10 CORR. CO .i--il' 8 ix I ci I, I DRAWING BY:Jo . 1 1 .' I �o c . O DATE: June 6, 2017 a_ \� 5 -3 o ` 0 0 0 5 O / JOB NUMBER: 2016285.50 QML i A2 O SI \ ..>,N.6,, TITHE: Li-5 \ FLOOR PLAN (-v c5c5 ,--.) 4 c - --.... - - - 5 ' (9) V A N 34 Q - 1 SHEET NUMBER: co CD OA ,. 4 T O I O N o F, � ® 1 40 LI C CD II 1 - _ FLOOR PLAN --�_1 COMMENTS: ii II E a, \-1 .4 SCALE: 1/4" = 1'-0" ``�\ V, 0 \ ��\�` E = d Il LEGEND NOTES BY SYMBOL 1. PROVIDE NEW 2X4 (AS SHOWN) CLEANROOM 11LE & ,CVS GASKETED GRID SYSTEM WITH HOLD DOWN CLIPS. CAULK NEW OR RELOCATED LIGHT PERIMETER OF ALL CEILING TILES AND PERIMETER ANGLE FIXTURE. RE: ELECTRICAL. TO WALL. PROVIDE HOLD DOWN CLIPS THROUGHOUT _ ENTIRE CEILING SYSTEM. RE: A-1.5a 2. MODULAR NPR. RE: MEP FOR ASSOCIATED CONNECTIONS. 3. NPR CEILING BY NPR MANUFACTRUER. \ / 4. NOT USED. Health 5. MODULAR NEGATIVE PRESSURE ROOM. / \ NEW FFU. RE: MECHANICAL. 5.1 MODULAR NPR LIGHTING. 5.2 D � P INSTALLED. UNITS, OWNER PROVIDED, CONTRACTOR N TAL STORE NUMBER: 48140 CORAM, INC. . 6. EXISTING CEILING TO REMAIN. 7. PROVIDE NEW 2X2 TILE & GRID SYSTEM WITH HOLD DOWN 7358 S W DURHAM RD. CLIPS TO MATCH EXISTING. RE: A-1.5a. SEAMLESSLY TIE PORTLAND, OR 97224 INTO EXISTING GRID ADJACENT. 8. +/- 13-4" MIN. AFF TO BIM OF EXISTING ROOF PROJECT TYPE: PHARMACY STRUCTURE. FIELD VERIFY AND COORDINATE WITH NEW DEAL TYPE: NPR MODULAR NPR MECHANICAL CONNECTIONS. CS PROJECT NUMBER: 0106369 ARCHITECT OF RECORD GPD Engineering and Architecture Professional Corporation 520 South Main Street,Suite 2531 Akron,OH 44311 330.572.2100 Fax:330.572.2102 4 CONSULTANT: 0 111 (---) 3 . $ .. . .. . ADJACENT TENANT SPACE DEVELOPER: �l ,__._. . 5.2 .... O .._ M 1 ,,,, _ .„,,„,„ ,,,,, ,,,,,,,,,,,,,,,,,o. 5.1 ir N1101 +I—,„,-I. jkily AL NPF . SEAL D 5. ,. HARK S. S. 1,01 K rn _ , 1 0, 4 I, O� AKRON, OH 2 „.,,‘ 0 , A, 11..... )/ �� • NO. 6036 • a ` PREP ROOM 4 ' Q \I 5.2 III / 102 - 01 fit to A)1N47,,„, ��1 li II 5.1 -/ _/ C/�,((/ ` SAI t 0 �� 06/12/2017 Air / \ \\ o / Ire) 0 1/ /1 NREVISIONS: \ i 4 U 11 I COMPO DING - 120 H if E 8 R STORAGE 7 \ / o o 8 �1 ►1 I SECURE STORAGE cs /I1ULE ............ 2 \ 1 ---L- ----- .--- --- 104 . /WALKIN / a 11i T CORK. /, 1 1 cc - I o / U \ ] i Ij DRAWING BY: ///\,,, o ;, 0 0 11 0 0 0 - v •-.� 1 DATE: June 6, 2017 a a JOB NUMBER: 2016285.50 op L / 1 TITLE: o m No _ ,� o V7 REFLECTED CEILING PLAN N. i 0 N- up SHEET NUMBER: � o c N C � ' co O ›,,3 ID N [/7 n 4 ,_ c � -1 . REFLECTED CEILING PLAN I I y I COMMENTS: II II E_ o A-1 .5 SCALE: 1/4" = 1'-0" c cn= o L7 SEISMIC POST SCHEDULE: 6'-O" FROM WALL MAX. 12'-O" O.C. TYP. BOTH DIRECTIONS SEISMIC CEILING GENERAL NOTES: ICC ESR-1308 NOMINAL SIZE POST TYPE ALLOWABLE LENGTH1. REFERENCED SOURCES ARE: 2012 INTERNATIONAL BUILDING CODE (IBC),AMERICAN SOCIETY OF TESTING 314"X 1/2"X 0.059" MTL.CHANNEL 26" y ��I! ������ ��� ��i����l� 1 I I I l w w w w w MATERIALS(ASTM C 635,ASTM C 636), AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE 7-08), &CEILING AND I IP CVS (2)314"X 1/2"X 0.059" MTL.CHANNEL(BACK-TO-BACK) 39" / I ! V \- 4 I I INTERIOR SYSTEMS CONSTRUCTION ASSOCIATION (CISCA). 1/2" 9/16" 33"- I -• I I I 2. PROVIDE SUSPENDED CEILING GRID SYSTEMS FROM A SINGLE SOURCE (MANUFACTURER), DO NOT MIX GRID 1 X X 0.059" MTL.CHANNEL ` I I 14 / \ / \ \ / \ /3. I SYSTEMS. (2)1 1/2"X 9/16"X 0.059" MTL.CHANNEL(BACK-TO-BACK) 44" / \ / - 1 5/8"X 1 1/4"X 0.0197" MTL.CHANNEL 106" I A3.0 I 3. PARTITIONS THAT ARE TIED TO THE CEILING AND ALL PARTITIONS GREATER THAT 6'-0" IN HEIGHT SHALL BEHealth {2)1 5/8"X 1 114"X 0.0197" MTL.CHANNEL(BACK-TO-BACK) 141" r ,r .1. / `1 i - _ LATERALLY BRACED TO THE STRUCTURE. WALL BRACING\ \ / SHALL BE INDEPENDENT OF THE CEILING SPLAY BRACING 314"P1 X 0.049"WALL THICKNESS EMT CONDUIT 47" 7 1\ /1 SYSTEM. 1°0 X 0.057"WALL THICKNESS EMT CONDUIT 61" ✓ ` 4. GENERALLY, SUSPENDED CEILING AREAS UNDER 1,000 SQUARE FOOT DO NOT REQUIRE HORIZONTAL RESTRAINT 1 114"0 X 0.{}65"WALL THICKNESS EMT CONDUIT 78" WIRE AND/OR RIGID BRACING. CONSULT RULING AUTHORITIES AND LOCAL CODES FOR MINIMUM CEILING AREA 1 112"0 X 0.065"WALL THICKNESS EMT CONDUIT 142^ 10 10 REQUIREMENTS. 9 5. PROVIDE SUSPENDED CEILINGS EXCEEDING 2,500 SQUARE FEET IN AREA WITH "SEISMIC SEPARATION JOINTS"TO STORE NUMBER: 48140 2"0 X 0.065"WALL THICKNESS EMT CONDUIT 150" 416 BREAK THE CEILING INTO INDEPENDENT UNITS LESS THAN 2,500 SQUARE FEET IN AREA THAT WILL ACT FAVORABLY 2 1/2"X 20 GAUGE MTL.C-STUD(SINGLE) 138" k e INA SEISMIC EVENT, RE: 1/A3.0. CORAM, INC. 2 1/2"X 20 GAUGE MTL.C-STUD(BACK-TO-BACK) - 180" 7358 S W DURHAM RD. 3 5/8"X 20 GAUGE MTL.C-STUD(SINGLE) _ 144" 6. ALL MAIN BEAMS (MAIN TEE RUNNERS) SHALL BE HEAVY-DUTY OR APPROVED EQUAL. INSTALL AT MAXIMUM OF 4'-0" 3 5/8"X 18 GAUGE MTL.C-STUD(SINGLE) 168" 2" MAX 2" MAX S APART, RE:A1.3, "FINISH MATERIAL SCHEDULE-CEILING ACOUSTICAL TILES AND GRID" FOR SPECIFICATIONS. PORTLAND, OR 97224 4 -0 O.C. TYP. 7. ALL CROSS BEAMS(CROSS TEES) SHALL BE HEAVY-DUTY OR APPROVED EQUAL AND SHALL BE CAPABLE OF PROJECT TYPE: PHARMACY 8'', BOTH DIRECTIONS ' CARRYING THE DESIGN LOAD WITHOUT EXCEEDING DEFLECTION EQUAL TO 1/360 OF ITS SPAN, RE: "FINISH DEAL TYPE: NPR SCHEDULE NOTES: MA41:)\..,.z,:) 9 MATERIAL SCHEDULE-CEILING -ACOUSTICAL TILES AND GRID" FOR SPECIFICATIONS. 1. THE INFORMATION PROVIDED IS FOR QUICK REFERENCE ONLY. OTHER RESTRICTIONS ANDPLY. 8. CHANGES IN CEILING PLANES REQUIRE POSITIVE BRACING AT TRANSITION. CS PROJECT NUMBER: 0106369 EX • 2. ALL STRUONS TS ANDY ALLOWABLE LENGTHS SHOULD BE VERIFIED BY APPROPRIATE AUTHORITIES. / - 4" d 8 ,O �; 9. ALL SEISMIC HANGER AND SPLAY WIRE SHALL BE 10 GAUGE GALVANIZED SOFT ANNEALED MILD STEEL OR CODE ,o -k p_ p p_ APPROVED EQUAL. ALL VERTICAL PERIMETER AND INTERMEDIATE HANGER WIRE SHALL BE 12 GAUGE GALVANIZED 3. WALL MOLDINGS SHOULD NOT BE USED AS STRUTS. \ gQ of o, , of o: SOFT ANNEALED MILD STEEL OR CODE APPROVED EQUAL. HANGER AND PERIMETER WIRE SHALL BE INSTALLED 4. A STRUCTURAL ENGINEER SHOULD BE CONSULTED FOR LENGTHS GREATER THAN 15'-0 I e` ARCHITECT OF RECORD i 14 _ �_ __ } 1 P -L VERTICALLY AT NO MORE THAN 10° FROM PLUMB(1 IN 6). ALL VERTICAL HANGER WIRE TIES SHALL BE"TWIST-TIE" 1 IN NATURE WITH (3)TIGHT TURNS AROUND ITSELF IN 3"OF LENGTH. ALL SPLAY WIRE TIES SHALL BE"TWIST-TIE" IN 11 I 6 • 6 I NATURE WITH (4)TIGHT TURNS AROUND ITSELF IN 11" OF LENGTH, RE: 21A3.0. A3.0 A3.0 © © A3.s� 10. ALL HANGERS AND RUNNERS SHALL BE ACCURATELY LEVELED AND SPACED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 11. PROVIDE LATERAL FORCE BRACING (VERTICAL COMPRESSION STRUTS AND SPLAY WIRES)AT 12'-0" MAXIMUM ON 12 SECTION AT SEISMIC CEILING GRID CENTER IN ALL DIRECTIONS AND 6'-0" MAXIMUM FROM FINISHED GRID EDGES AND WALLS, RE: 9/A3.0. SEE"SEISMIC ._ POST SCHEDULE" FOR COMPRESSION STRUT SIZES. A3.0 SCALE: NTS GPD Engineering and Architecture 12. SEISMIC SPLAY WIRES SHALL BE(4) WIRES ATTACHED TO THE MAIN BEAM (RUNNER). WIRES SHALL BE ARRAYED 90° FROM EACH OTHER AND AT AN ANGLE NOT EXCEEDING 45° FROM THE PLANE OF THE CEILING. SPLAY WIRES Professional Corporation ...--..-.-...---- (1),.... ,:277, ��� t, / / // � /,(/// /J� W.7������ ���lJ������������ SHALL BE INSTALLED WITHIN 2" OF THE CONNECTION OF THE VERTICAL STRUT TO SUSPENDED CEILING. SPLAY 520 South Main Street,Suite 2531 / LEGEND. Akron,OH 44311 WIRES SHALL BE ATTACHED TO THE CEILING GRID AND STRUCTURE ABOVE IN SUCH A MANNER AS TO SUPPORT A X X X X X X DESIGN LOAD OF NOT LESS THAN 650 POUNDS OR THE ACTUAL DESIGN LOAD, WITH A SAFETY FACTOR OF 2, 330.572.2100 Fax:330.572.2102 / WHICHEVER IS GREATER, RE: 6/A3.0 AND 5/A3.0. �/ A3.0 2 X 44• • X X X 13. ATTACH HANGER WIRES ALONG MAIN RUNNERS AT 48" O.C. WITH MAIN RUNNERS PARALLEL TO EACH OTHER AT NO COMPRESSION STRUT AND SPLAY WIRESo MORE THAN 48"APART, CREATING 48" HANGER WIRE ARRAY IN TWO DIRECTIONS. / �` -. (15) r�j 14. TERMINAL ENDS OF EACH MAIN RUNNER AND CROSS TEE SHALL BE SUPPORTED WITHIN 8" OF EACH WALL OR CONSULTANT' 00F/ • 8" 8"M � X HANGER AND PERIMETER WIRES FINISHED GRID EDGE WITH A PERIMETER WIRE. / MAX / �� i aft. •� J / �� / �- _ 15. PROVIDE ARMSTRONG 7/8"X 7/8"WALL ANGLE MOLDING IN CONJUNCTION WITH ARMSTRONG BERC-2 SEISMIC WALL /g 111, '\ } ♦ X �{ X % 2" BEAM END RETAINING CLIP (BERG 2) CLIPS TO SUPPORT TERMINAL ENDS OF MAIN TEES AND CROSS TEES AT WALLS. CEILING GRIDS SHALL BE © POSITIVELY ATTACHED TO WALL MOLDING WITH COLOR MATCHING POP RIVETS ON ADJACENT WALLS AND FREE TO 11 �� 6 SUSPENSION GRID EDGING AND TRIM SLIDE WITH A 314"GAP ON THE OPPOSING WALLS. USE"BERG-2 SEISMIC CLIPS BY ARMSTRONG"TO PROVIDE A3.0 A3.0 0 0 X10 APPROVED SLIP-JOINT. REFER TO ICC EVALUATION SERVICE REPORT: ERS-1308`, SECTION 4.4.3. A3.0 r ® 16. LIGHT FIXTURES AND MECHANICAL DEVICES SHALL BE POSITIVELY ATTACHED TO THE SUSPENDED CEILING SYSTEM iii�I SEISMIC GRID AT WALL - UNATTACHED X X ♦ �, ' X X X �` -III----- SEISMIC SLIP JOINT AND CAPABLE OF RESISTING 100%OF THE FIXTURE WEIGHT IN ANY DIRECTION, RE: 8/A3.0. A3.0 1 SCALE: NTS /, 0 I -.4 17. LIGHT FIXTURES WEIGHING LESS THAN 56 POUNDS SHALL HAVE TWO WIRES ATTACHED AT DIAGONAL CORNERS OF OD `'�/ THE LIGHT FIXTURE TO THE STRUCTURE ABOVE. THESE WIRES MAY BE SLACK. SLACK WIRES SHALL BE CAPABLE �o I Q HVAC-24"X 24"AIR DIFFUSER OF WITHSTANDING DESIGN LOADS AS REQUIRED BY LOCAL CODES AND RULING AUTHORITIES.. TMP 18. FOR CEILINGS WITHOUT RIGID BRACING, SPRINKLER HEAD PENETRATIONS SHALL HAVE A(2) INCH OVERSIZED RING, , X ♦ X �r X f �X X f \ / SLEEVE OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FREE MOVEMENT OF AT LEAST(1) INCH IN ALL HORIZONTAL DIRECTIONS. `. 21 24"X 48" RECESSED 19. NO SUSPENDED CEILING ASSEMBLY WITHIN THE PROPOSED RENOVATION SPACE INVOLVES A SUSPENSION LENGTH DEVELOPER- - 0 FLUORESCENT LIGHT FIXTURE GREATER THAN 66".6'-0"MAX / 12'-0"MAX /x _ 12'-0"MAX / 6'-O"MAX 20. SPRINKLER HEADS AND PENETRATIONS THROUGH THE CEILING MUST BE FITTED WITH A 2"OVERSIZE RING, / . SLEEVE, OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST 1" IN ALL _ x 8, is 4 0 ♦ ,X X - HORIZONTAL DIRECTIONS . ALTERNATIVELY, A SWING JOINT THAT CAN ACCOMMODATE 1" OF CEILING MOVEMENT � 111 DASHED LINE FLOOR LINE .". ". IN ALL HORIZONTAL DIRECTIONS IS PERMITTED TO BE PROVIDED AT THE TOP OF THE SPRINKLER HEAD EXTENSION. ..„.... . i • - _ OF RACEWAY BELOW • t , ,` x x / X r / # SEISMIC CEILING KEY NOTES • '1,44,..,„:4444I4.%•• FINISHED INTERIOR WALL i '"• / HEAVY-DUTY T-BAR GRID CROSS TEE. PROVIDE CROSS PROVIDE BRACING AS NECESSARY TO MAINTAIN HANGER �� 6 , X X X X r % �J TEES AND MAIN TEES WITH THE SAME PROFILES WHERE 1 AND SPLAY WIRE ALIGNMENT, RE:2/A3.0. / ©Q / A . "OPEN"GRID IS INSTALLED.SEE SPECS./ 8 •HEAVY-DUTY T-BAR GRID MAIN RUNNER,SEE SPECS. OPEN ENDS OF T-BARCONNECT HANGER IGRID.RES T NOT MORE THE 3"FROM SEAL" QED AR / g� SUSPENDED 2x2 OR 2x4 CEILING GRID n �< C ci SEISMIC G R I D AT WALL - ATTACHED �� \ / FIN SHOMATERIAL AND ACCESSORIES LEGEND SEE O SIDE PROOF SPLICE CAP TO ALLOW MOVEMENT ON OPPOSITEDE 4"T-BAR CAP SLEEVE AS SLIP-JOINT. CRIMP �~� r� A3.0 SCALE: NTSUSTICAL CEILING TILE WHERE 18 o A3.0 SCALE: NTS O a END ONLY. AKRON. OH • �' �� �/ PROVIDE MTL.TOP CLIP TO FASTEN COMPRESSION ccT) Y /�w///���` \ ' / STRUT POST TO ROOF STRUCTURE PER ICC REPORT 7/8"X 7/8"MTL.WALL ANGLE SCREWED TO WALL WITH • NO. 6036 • `-' 0 C19/ APPROVED FASTENERS,SEE SPECS. -� I L6 j !/ O PROVIDE FASTENERS AS APPROVED BY ICC REPORT 1308. ( PROVIDE COLOR MATCHING POP RIVETS TO FASTEN i �� (1/45-4re. vs(i' I / \20/ TERMINAL ENDS pF MAIN RUNNER AND CROSS TEES TO Ile � O1 7N ,�, - [ \41) PROVIDE SPRING CLIP AROUND VERTICAL HANGER WIRE WALL ANGLES REQUIRING ATTACHMENT AND GRID ENDS i i 1 �' 6 AS SHOWN. TERMINATING IN TRIM. 06/12/2017 -44 ver ::::: ® INHX III ! 9 _ 7O WIAPTH#10 XLY SIO TO SELF-TAPPING STLON STRUT SCREW OR AND SECURE 21 CODE-APPROVED CLIPS AND FASTENERSACH HVAC-DIFFUSERS O SUSPENSION GRID ON TWO WITH * 4 Nil / 0 REVISIONS: ‘,„ P v f 45' CODE-APPROVED EQUAL. OPPOSITE SIDES OF THE FIXTURE TO THE GRID MAIN ,E �� j _ RUNNERS. PROVIDE TWO DIAGONALLY OPPOSED HANGER \ INSTALL VERTICAL HANGER WIRE AT INTERSECTION OF WIRES AT CORNERS OF DIFFUSER TO THE STRUCTURE °' 21 �/ f AX 8 0 / /..',': O•.// r O I_ : . .•• . -� MAIN AND CROSS TEE. VERTICAL SHALL BE DEFINED AS± ABOVE. WIRES MAY BE SLACK,RE: 7/A3.0. QINN.„, 14.00....e. 0 l10° 1 IN 6 FROM PLUMB, RE:21A3.0. .'• • I� 22 PROVIDE SEISMIC SEPARATION JOINTS AS REQUIRED FOR NN �/ : . . PROVIDE(4)SPLAY WIRES ATTACHED TO MAIN RUNNER O CEILING AREAS IN EXCESS OF 2,500 SQUARE FEET, RE: E • • • 1•' '`` '� NOT MORE THAN 2"FROM THE INTERSECTION OF MAIN 11A1.3 "REFLECTED CEILING PLAN"FOR SEPARATION 45 d ''',•' i ' MAX . • ; �?; i) ' :41.141‘4111111milniuni::),,,11r...„ -'°'.#'1:.. ' ' RUNNER AND CROSS TEE. LAYOUTS AND 11A3.0. '� „. Q :. . : :.•. : 45' I) • • •:• / © / ./ ru10TELESCOPINGELECTRICALMETALLIC TUBING(EMT)AS NOT USED. © / © :' �► ; .:. : : : :•. : ,'�f MAX © © COMPRESSIONSTRUT, RE:"SEISMICPOSTSCHEDULE"o /•cc ;/��1►rrrriuuiurrrrrrrquniiiiiMr�� BELOW. NOT USED. .. \, ,. © �. © METAL STUD 24BACK-TO-BACK C-STUD AS ALTERNATIVE METHOD FORa \/ COMPRESSION STRUT SYSTEM, RE:"SEISMIC POST 01 SEISMIC GRID wl SEISMIC GRID wl 6 E" M "T. COMMPRESSION STRUT 5 COMMPRESSN STRUT DETAIL SSCHEDULE". POSITIVELY TRUCTURE ABOVE WIHATTACH POSTS TO FASTENIRID AND 0SLACK WIRE AT DIAGONALLY OPPOSING CORNERS OF rn cK 8 L I G H T FIXTURE D ETA I L 7 A I R DIFFUSER DETAIL ES A3.0 SCALE: NTS © A3.0 SCALE: NTS 12 PROVIDE VERTICAL"PERIMETER"SUSPENSION WIRE PROVIDE CODE-APPROVED FASTENERS FOR HANGER o A3.0 SCALE: NTS A3.0 / SCALE: NTS rib Q � WITHIN 8"OF THE ENDS OF MAIN RUNNERS AND CROSS 26 WIRE CONNECTIONS. DRAWING BY: ' TEES ALIKE TERMINATE AT WALLS AND FINISH WITH EDGE 0 TRIM. PROVIDE 1"WIDE X 2" LONG X MINIMUM 12 GAUGEDATE: June 6, 2017 0 5 6 STEEL STRAP AS HANGER CEILING CLIP. 0 8 MAX. 3 f 6 /� PROVIDE 3/4"GAP BETWEEN WALL ANGLE AND GRID T-BAR _ �� _ © \ / END AT WALLS THAT REQUIRE SLIP-JOINT(UNATTACHED) PROVIDE CODE-APPROVED HEAVY-DUTY 90°ANGLE JOB NUMBER: 2016285.50 Q / r7�� r7�� f CONDITION. INSTALL 2"BEAM END RETAINING CLIP 28 CEILING CLIP FOR HANGER WIRE. °0° o : ! 1 ,•� (BERC-2)TO PROVIDE SLIP CONDITION. TITLE: 1 6 cn '.. Q r�y� 1 •••••\ 0 : • : '. : : :I! . t -t-" 14 ROOF STRUCTURE AND JOISTS FOR REFERENCE ONLY AS SEISMIC CEILING DETAILS 4p V ".� / TYPE OF CONSTRUCTION MAY VARY. CONNECT TO +� / STRUCTURE ABOVE USING METHODS AS APPROVED BY N '1�1 J �/ LOCAL CODES AND AUTHORITIES. z Z �� �► •F SHEET NUMBER: 15 a 7r`-) VERTICAL �``, ��� SPLAYED "�h �r/ 15 CODECAPPROVED CLIPS AND FASH LIGHT FIXTURES TO TENERS ON GRIDENSION WITH TWO EID CO ,� ,f hrrrrrnuwrrrrrrrrrrrrurrrrrr+ L �, �, r z 'S / 0 OPPOSITE SIDES OF THE FIXTURE TO THE GRID MAIN A - 1 ,, 5 a �� CEILING G R I �'� CEILING GRID RUNNERS. PROVIDE TWO DIAGONALLY OPPOSED HANGER 0 o WIRES AT CORNERS OF LIGHT FIXTURE TO THE u_ ii 0 .0 i4 HANGER WIRE ATTACHMENT 3 NOT USED 2 HANGER WIRE CONNECTION 0 EXPANSION JOINT DETAIL STRUCTURE ABOVE. WIRES MAY BE SLACK,RE:8/A3.0. COMMENTS: ii II E \ A3. SCALE: NTS A3.0 SCALE: NTS A3SCALE: NTS \ A3. SCALE: 3"= 1'-0" U] 0 N D 0 1 NOTES BY SYMBOL 1. NEW RTU, RE: MECHANICAL. RE: STRUCTURAL FOR CURB AP CVS DETAIL 2. OUTLINE OF COMPUNDING & NPR SUITES. 3. INFILL EXISTING PENETRATIONS WITH ROOF DECK, INSULATION AND ROOF MATERIAL TO MATCH EXISTING SYSTEM. FLASH SHEET PATCH TO EXISTING ROOF WEATHER TIGHT PER MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS AND TO MAINTAIN EXISTING WARRANTY. CARRY METAL DECK Health TO NEAREST STRUCTURE AND PROVIDE STEEL ANGLE SUB-FRAMING AS REQUIRED. 4. EXHAUST FAN. RE: MECHANICAL STORE NUMBER: 48140 • CORAM, INC. 7358 S W DURHAM RD. PORTLAND, OR 97224 PROJECT TYPE PHARMACY DEAL TYPE: NPR CS PROJECT NUMBER: 0106369 ARCHITECT OF RECORD GPD Engineering and Architecture Professional Corporation 520 South Main Street,Suite 2531 Akron,OH 44311 330.572.2100 Fax: 330.572.2102 CONSULTANT: DEVELOPER. / — — _ _ _ _ _ _ v / , (Cie 1 SEAL: D ��I RTu_2 � - - - - - - �- tE AI>'C' lik j'''`C") SALO I711:Arr1 i 1711 7 N.. / / s. I AKito V', UH O • I • N U. U0;36 • z_ N z / \ t P"\,,,4 A RTU-1 tS QLn \ \ \ C j,; .! ► -74-C \ <\,\N\ / ) i-.4%\ \ \ I 06/12/2017 Q) \ I \ _ _ _ _ ��� REVISIONS: i L U .aaa`.. ar. '•1, 1f� aa•,,, aa� iViU 1 I I C U O 0 O 0 3 1 1 U 1 1 d L \ - - - - - - _ _ _ _U H n / © DRAWING BY: o DATE: June 6, 2017 O a c JOB NUMBER: 2016285.50 a co TITLE: r U ROOF PLAN n 1 0 N oo r• co �. SHEET NUMBER: a) 4 C N (0 0 ›7,5 ).; Q" a o A 'I ,_ 6 . _,„ ti, �i� ROOF PLAN �, I0 COMMENTS: ii R E c A-1 .3 SCALE: 1/4" = 1'-0" Cn 0 - • TOP TRACK 362T162-68 (ICC-ESR #2049) W/ (2) #10 x 1" SCREWS ,CVS EXTEND PARTITION TO !LEN (ICC-ESR #2196) 0 24" UNDERSIDE OF DECK ABOVE 0.C. VERTICLIP SL362 3-5/8" 362S162-68 (ICC-ESR #2049) Healtla (50 KSI) METAL STUDS 0 12" O.C. (ICC-ESR #3064P) it 1/2" DIAMETER HILTI STORE NUMBER: 48140 5/8"GYPSUM BOARD KWIK BOLT TZ ® 32 FINISH TO MATCH EXISTING 0.C. WITH 3-1/4" EMBED CORAM, INC. ADJACENT WALLS INTO SLAB. (ICC-ESR 7358 S W DURHAM RD. ROOM BASE, #1917) MATCH EXISTING IN PORTLAND, OR 97224 FINISH FLOOR PROJECT TYPE: PHARMACY 4$" @ Al DEAL TYPE: NPR MATCH © A2 CS PROJECT NUMBER: 0106369 Al TYPICAL NON-RATED WALL TO DECK ARCHITECT OF RECORD A2 TYPICAL NON-RATED WALL TO DECK i 1 TYPICAL PARTITION A-6.1 SCALE: 1" = 1'-0" ._ GPD Engineering and Architecture Professional 'on ,AS SCHED., AS SCHED.ir- CART/TRAY 520 South Main Street,Suite 2531 PASS-THROUGH. TRAY Akron,OH 44311 PASS-THROUGH, TERRA 330.572.2100 Fax: 330.572.2102 1b 1b © x Tr, UNIVERSAL 2636-060-2, o EP304SS, CLEANSEAM, i � 14 24"WX24"DX24"H • bil A-6. (CHAMBER SIZE), WALL Pe �, 1/1 � ' IC) N MOUNT. CART CONSULTANT' _ �� PASS-THROUGH, TERRA • t Q 'i UNIVERSAL 2636-14D, cn 17 I ili, ---, I ® O "' EPI6GASS, CLEANSEAM, 0I: ®- 32"WX48"0X42"H p , i (CHAMBER SIZE), FLOOR f' 6. .10011 .��� A.: \ b n' ( -_-. ) _ I _ MOUNT WITH RAMP. 32 (A) 0 ELEV. NEG. PRESSURE CD ELEV. NEG. PRESSURE 4 ELEV. NEG. PRESSUREEELEV. NEG. PRESSURE i6- DOOR TYPES . @ PASS- THROUGHS C-2-- 6.1/ SCALE: 1/4" = 1'-O" SCALE: 1/4" = 1'-0" A-6.1 SCALE: 1/4" = 1'-0" (53 SCALE: 1/4" = 1'-O" A-6.1 SCALE: NTS CO-6.1 SCALE: 1/4"=1'-0" NOTE: EFR TO \ PEQUIPMENT SCHEDULE 13/A- 6. 1 , TYPICAL DETAILS 2 THOUGH 12. IkP � EQUIPMENT SCHEDULE # 0 0 EQUIP. # " DESCRIPTION DEVELOPER: lb 48 HOOD 1„ 2 INTERCOM 10a II 7 STAINLESS STEEL BENCH 18"x36"x18" `.. I ACCESS DOOR BY BEST 9 MAGNEHELIC GAUGE 2'-0° ACCESS DOORS MODEL# 13 GOWN HOOK BA-AHD-SS-24-24. 14 MOP HOLDER �' rill COORDINATE LOCATION 16d STAINLESS STEEL SHELF 18"x48"x72" ■pm woo I !-� WITH SINK/EYEWASH AND 17 REFRIGERATOR (HAZARDOUS) Pa ```s 5 Pa 7 RETURN AIR DUCT. 31 STAINLESS STEEL SHELF 24"x36"x72" • , s •. Q I�I O N 32 EYEWASH • I I Q c I M O II I I I �e��■� - ��� A 1 -9 SEAL m ® � .„Ev Ake 8 ELEV. NPR ANTE g ELEV. NPR ANTE Co) EV. NPR ANTE ELEV. NPR ANTE (12\ ELEV. PREP /NPR ANTE 13 NPR EQUIPMENT SCHEDULE �� S ��SALOPEK 51 rgi A-6.1 SCALE: 1/4" = 1'-0" A-6.1 SCALE: 1/4" = 1'-0" A-6.1 SCALE: 1/4" = 1'-0" Cii) 6SCALE: 1/4" = 1'-0" A-6.1 SCALE: 1/4" = 1'-0" A-6.1 AKL O�'; OH 0 - - • NU. 60 3.36 • w SCHEDULED DOOR HARDWARE SCHEDULE D00R ASD HAVE SCHEDULE ��� -'vim c � c1 DOOR DOOR FRAME FIRE zip 1/2" TEMP. HARDWARE GROUP No. 1 - (SPECIALTY DOORS) Hardware Group No. I-HMI-700-EAC - (SINGLE WITH ELECTRIFIED RIM PANIC HARDWARE X ROOM TAG TYPE SIZE DETAIL RATING HARDWARE NO. NOTES MAIL MATE .� GLASS (TYP.) SMOKE GASKETING X CARD READER LABEL 06/12/2017 a) Provide each SGL door(s) with the following: WD HGT THK HEAD JAMB SILL tn 1 EA. CLOSER REVISIONS: i VESTIBULE 1 B 3'-0" 7'-0" 1 3/4" SCWD H.M. I-HMI-700-EAC 4. a 1 EA. LOCK SCHLAGE INSTITUTIONAL FUNCTION HANDLE LOCK ND82PD Provide each SGL door(s) with the following: - D EN1 EA. STRIKE VON DUPRIN ELECTRIC STRIKE 6211 FAIL SECURE PREP 2 B 3'-0" 7'-0" 1 3/4" SCWD H.M. I-HM1-700-EAC 0 � 2 EA. EMERG. INTERLOCK RELEASE BUTTON Qty Description Catalog Number COMPOUNDING 3 A 3'-0" 7'-0" 1 3/4" SCWD H.M. MATCH EXISTING 4. 1 EA. PUSH TO EXIT BUTTON 3 EA HINGE 58B1 SERIES AS SPECIFIED IVE COMP ANTE 4 A 3'-0" 7'-0° 1 3/4" SCWD H.M. MATCH EXISTING 4. 1 EA. CARD READER 1 EA POWER TRANSFER EPT10 VON / co H.M. FRAME (TYP.) 1 EA ELEC PANIC RX-LC-LD-99-L-E996-FSE VON SECURE STOR. 5 B 3'-0" 7'-0" 1 3/4" SCWD H.M. MATCH EXISTING HARDWARE GROUP No. 2 - (SPECIALTY DOORS) HARDWARE SECURE STOR. 6 B 3'-O" 7'-O" 1 3/4" SCWD H.M. MATCH EXISTING o 1 EA RIM CYLINDER AS REQUIRED SOH NPR ANTE 7 A 3'-6" 7'-0" -- -- -- -- -- 1 1. oProvide each SGL door(s) with the following: 1 EA PERMANENT CORE AS SPECIFIED BES NPR 8 A 3'-6" 7'-0" - -- -- -- -- -- --- 2 1. 1 EA. CLOSER 1 EA SURFACE CLOSER 4040XP EDA LCN SECURE STOR. 9 EX. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. 3. 4 JAMB / HEAD SIM 1 EA. LOCK SCHLAGE INSTITUTIONAL FUNCTION HANDLE LOCK ND82PD ---1 EA. STRIKE VON DUPRIN ELECTRIC STRIKE 6211 FAIL SECURE 1 EA KICK PLATE 8400 10" X 2" LDW B-CS IVE o (-1 -6.1/ SCALE: 1 1/2" = 1'-O" 2 EA. EMERG. INTERLOCK RELEASE BUTTON 1 EA STOP WS407/FS436 AS SPECIFIED IVE 1 EA. PUSH TO EXIT BUTTON 1 EA SEALS 488S ZER JOO AN D HAVE SCHEDULE NOTES --- 1 EA. PUSH TO ENTER BUTTON 1 EA DOOR SWEEP 39 ZER GENERAL NOTES: ii 1 EA SADDLE THRESHOLD 54515471548 (VERIFY JAMB DEPTH) ZER 1. SEE ELECTRICAL AND PERSONAL SECURITY DRAWINGS FOR ADDITIONAL REQUIREMENTS FOR BALANCE OF DOOR HARDWARE. eff 1 EA DOOR CONTACTS 10760 BY SECURITY INTEGRATOR GEl HARDWARE TO BE PROVIDED BY THIS CONTRACTOR UNLESS OTHERWISE NOTED. 12L (PREP DOOR FRAMES 2. PAINT ALL EXISTING H.M. FRAMES TO MATCH EXISTING THROUGHOUT THE SUITE. o 1 EA POWER SUPPLY BY SECURITY INTEGRATOR 3. ALL THRESHOLDS TO BE MAXIMUM 1/2" IN HEIGHT AND ALL DOOR OPERATING HARDWARE TO BE LEVER STYLE & MEET DRAWING BY: 1 EA CARD READER BY SECURITY INTEGRATOR ADAAG SPECIFICATIONS FOR TYPE, STYLE & OPERATING FORCE, INCLUDING ALL DOOR CLOSER LOCATIONS. 4. KEY NEW LOCKS AS REQUIRED. COORDINATE W/ TENANT REQUIREMENTS. DATE: June 6, 2017 t 5. ALL DOORS TO HAVE CLOSERS, ADD TO EXISTING DOORS AS REQUIRED. NOTE 1: FACTORY PREP AND LOCATE ALL DOOR HARDWARE PER MANUFACTURER'S 6. REFER TO 6/A-6.1 FOR DOOR TYPES. JOB NUMBER: 2016285.50 Q ! TEMPLATES AND APPLICABLE CODES. Lo ▪ 0 NOTE 2: REFER TO AND CROSS-REFERENCE PHYSICAL SECURITY DETAILS WITHIN SUBMITTAL NOTES: (GC PROVIDED AND INSTALLED, U.N.O. - SEE SECURITY DRAWINGS) TITLE: o j PACKAGE. 1. DOOR AND FRAME ASSEMBLY AND HARDWARE BY MODULAR ALL WIRING AND CONNECTIONS BY DIVISION 26. NPR VENDOR. INTERIOR ELEVATIONS '� 1 OPERATIONAL DESCRIPTION: 2. COORDINATE WITH OWNER FOR HARDWARE TYPE. AND DETAILS o coBOTH IMMEDIATE EGRESS ALWAYS ALLOWED. ACCESS BY KEY OR BY CARD READER. CARD 3. PROVIDE ANCDIKSET ONS FOR DOOR CONTACTSINSTALL BLANKPAND EALARM.SADFIX N kci N E READER WILL UNLOCK TRIM AND ALLOW ACCESS. REQUEST TO EXIT AND DOOR POSITION DOOR TO FRAME WITH TACK WELDS AT TOP, BOTTOM AND SHEET NUMBER: SWITce, CH CONNECTED TO BUILDING'S SECURITY SYSTEM. CENTER. -1 0 E 4. DOOR, FRAME AND HARDWARE ALREADY PURCHASED BY A 6 n -FA CVS. › Eo L C II II II COMMENTS: v SD 0 - = o GWB TOP CAP PREPARE& PAINT • . EXPOSED GWB. • . . •' IP CVS / / ,( / / / / / / / / / / / / /•/ / / / / / T susP. © CLG. Mr - . NOTES: \/ WALDL BOARD P --... „ 1 Health 1. INSTALL WALL BASE TO MATCH EXISTING. NOTE: RE: 6/A-7.1 ATA FOR • \ COORDINATE IN FIELD JOINT DETAIL ALL NEW - PANEL FINISH FRP• CHASE WITH If�l FRP EDGES. . / (SEE PLAN) SCHEDULED WALL ) i WITH BOX HEADER • '`� ¢J VERIFY WITH MECH. GWB TOP CAP PREPARE & —� ! STORE NUMBER: 48140 VLA PAINT EXPOSED GWB. = FRAME AND GLASS NEW 2 112 METAL STUD PROVIDE CONTINUOUS AT ROOMS WITHOUT w FRA FLUSH WITH WALL CORNER COVE @FRP WALL PARTITION TO 6"ABOVE CEILING, HEIGHT SHALL 7358 S W DURHAM RD. TRIM INTERSECTION {TYP.) FINISHED CEILING ABOVE WITHMATCH ADJACENT - '� (1) LAYER 518"TYPE X • CLEAN SUITE HEIGHT a PORTLAND, PAPERLESS GYP. BOARD OR 97224 EXPOSED SIDE AND FRP `° PROJECT TYPE: PHARMACY L...'- • - ' RA GRILLE WITH DEAL TYPE NPR \ PANEL FINISH WITH TRIM z .• :. n• •�..•� DAMPER& FILER TO SUSPENDED CEILING � � � • � T - - COORDINATE1r / / -'�"TEMPERED GLASS, ,. mm.. WITH MECH- FLUSH WITH FRAME CS PROJECT NUMBER 01 06369 - -- -_-. --- OPPOSITE SIDE EACH SIDE L3 NEW RETURN AIR DUCT - SUSP. _ _ '. -.............._..__... • _ ,.__ CLG. • [_ F �• ' _ _- .-_ .__. -.-._...-.. - - --- --- VINYL COVE DUCT I/ w ,; - BASE GMATCH SEALANT ARCHTECT OF RECORD cwn a I EXISTING COMPOUNDING - = - (CONTINUOUS) - ROOM WALL w �; I_1 - , ,, i — CAULK/SEAL, TYPICAL - - -• \ METAL STUD e AND GYP WAL �' _ . . L �i � SCHEDULED WALL • • BOARD CHASE �fl WITH EXISTING SILL „••••40""ik WALL I_,' _. . \i\___ =LOCKING oAL T GPD Engineering and Architecture Professional Corporation 1L j• 520 South Main Street, ron,Suite 42531 (4 � TYPICAL GMP WINDOW SECTION 330.572.2100 Fax: 330.572.2102 A- (71 PLAN (-; 1 ELEVATION n SECTION J SCALE: N.T.S. A-7.1 SCALE:1 1/2"=1'-O" A-7.1SCALE: N.T.S. A-7.1 SCALE:1 1/2"=1'-O" `J � •-------• � CONSULTANT: PANEL JOINT i" CLEAR TEMPERED SAFETY GLASS MODULAR WALL PANEL GLASS ADHESIVE - TO STOP I Alit_ THIS PORTION OF GLASS BLOCKED OUT TO HIDE ADHESIVE STAINLESS STEEL FRAME& STOP WOOD BLOCK - - SEALANT SEALANT CONT. PROVIDE FRP JOINT COVER AT -, @ TOP,BOTTOM ALL MODULAR WALL VERTICAL AND SIDES JOINTS IN ANTE RM., PREP RM. DEVELOPER: AND COMPOUNDING RM. FROM TOP OF COVE BASE TO CEILING EPDXY PAINTED GWB OR NOTE. WALL ANGLE FRP PANEL FINISH , REQUIRES MECHANICAL AND ELECTRICAL REMOVAL ^ AND RE-INSTALLATION OF DEVICES, CONDUIT, ETC. � (--€7- WALL JOINT COVER DETAIL l GMP WINDOW SILL (HEAD SIMILAR) A-7.1 SCALE: NTS A-7.1 SCALE: N.T.S. ti� r� C) MARK S. 5:1LoPEx 51 i 1 I AMI I AKRON, OH _ I I I I !� NO. 603 1 I 1• i ii a� I I ! I 11 }1 ; I II �( 10.1# , 7 R. 1 1 1 I I I I . I .. 06/12/2017 a II 1 - METAL STUD, GYPSUM i PROVIDE STEEL '- I I ,: .i ,: BD. & FRP FINISH TO REVISIONS: o CHANNEL H-FRAME MATCH MODULAR IF REQUIRED ' WALL THICKNESS U CEJ --4--I-- r- 7 L Q Q� 0 1 I / 2-3/4"THICK I WALL PANEL JOINT / MODULAR WALL o • I I WITH BATTEN STRIP /� (FIELD VERIFY) 0 • I I TRIM V c L _ _ _ _ I 0 U c, d Z REPLACE EXISTING 6 TWO PIECE WELDED ce DOORI , FRAME AND �� STAINLESS STEEL 1- HARDWARE FRAME TO WRAP DRAWING BY: 0 1 i---1__F-L_. MODULAR WALL PANEL J/f L I DATE: June 6, 2017 ti I o_ m Lo JOB NUMBER: 2016285.50 Q 7 Li 1 TITLE: .r7) 7:3 . I iiii / iiiii // iii / cNi a ( .' 1. REMOVE EXISTING DOOR AND FRAME. DETAILS — " 2. INSPECT WALL PANEL STRUCTURAL INTEGRITY. n i 3. PROVIDE H-CHANNEL FRAME FOR MOUNTING NEW DOOR IF REQUIRED. REMOVE WALL 5 Lo PANEL TO NEAREST BATTEN. INSTALL H-FRAME, SECURED TOP & BOTTOM. IN-FILL WITH co N- " METAL STUD, GYPSUM BOARD & FRP FINISH TO FLUSH WITH WALL THICKNESS OF SHEET NUMBER: c o MODULAR WALL PANEL. REWORK CEILING, REINSTALL BATTEN TRIM OR PROVIDE NEW HEAD N c TO MATCH. L o• 0 4. MOUNT NEW DOOR FRAME& HARDWARE, SEAMLESS, FLUSH WITH ADJACENT WALL w N j PANEL FINISH. / c. 1 - ALTERNATE DOOR REPLACEMENTDETAIL _ _ ii -- LZ li II � ( 9DooR REPLACEMENT DETAIL (10 CLAMSHELL STYLE FRAME COMMENTS: -▪ al A-7.1 SCALE: NTS A-7,1 SCALE: NTS cn 0 - �� �� FACTORY INSULATION if 't 9„ 1ANCHORS TO BE 3/8" DIA. LAG <3.--6) -1•a BASE CHANNEL GENERAL NOTES BOLTS 3" MIN. PENETRATION �� '., RTU 1. REINFORCING TO BE ADDED AT JOISTS THAT SUPPORT AHU. r r ' ' NEOPRENE GASKET FIELD 4 ' inEl A*CVS I I MOUNTED (SEE NOTE 1) FACTORY WELDED 2. CONTRACTOR IS RESPONSIBLE FOR VISITING THE PROJECT SITE TO VERIFY EXISTING 4" rw� f CONDITIONS PRIOR TO SUBMITTING THE BID. 12" 'k oior••� OR BOLTED 1 '��"�� I:•:•:•:•:4 3. MANUFACTURED LUMBER TO BE 2.0 MICROLAM LVL. Health I i } I ** ac ' % \ I DUCT RAIL 4. DIMENSIONAL LUMBER TO BE #2 SPF KILN DRIED Fb=875 PSI MIN, Fv=135 PSI MIN. 2"x4" / 5. ANCHOR CURB TO ROOF DECK USING " DIAMETER LAG BOLTS, " FACTORY MOUNTED / E MEMBRANE 3" MIN. PENETRATION INTO 2x6. FLASHING - - - '` 3"x2"x3/16" ANGLE PRE-DRILL } STORE RIMER CURB DIMENSIONS INSIDE TO INSIDE CURB WALLS - - 12" FOR 1/2" BOLT CORAM INC. RTU-1 RTU-2 • 1 1/2" RIGID INSULATION - - ' 1/2" HOLES AT 24" C-C STRIP f,- ** 1 1/2"x1 1/2"x1/8" ANGLE PRE-DRILL 7358 S W DURHAM RD. "A" :121 1/2" 141 1/2" (;----: ELEVATION /'_ = FOR 1/2" BOLT INSTALLATION KEYED NOTES PORTLAND, OR 97224 5-1.0 SCALE: NTS IN CENTER OF BOTTOM MEMBRANE "B" 50 3/4" 60 3/4" FLANGE ROOF A,, - - �� = PRO {+"T MS PHARNII(.'Y "C" 48 1/4" 40 1/4" ANCHORS TO BE 3/8" O GLUE AND NAIL NEW MEMBERS TO EXISTING W/ 16D NAILS @ 8" O.C., STAGGERED. DEAL TYPES 'FR DIA. LAG BOLTS 3" MIN. SEE DETAIL 2. "D" 28 1/4" 20 1/4" PENETRATION //////rll /r/// l//////f////,V////////////A0 PROVIDE SIMPSON LUS26, LUS26-2 28 OR 210 JOIST HANGERS TO EXISTING FRAMING. 's PT 0106369 "E" 117 1/2" 137 1/2" ,'� TYP. 2" ,' 7 1/8" 3" MIN. _ EXISTING PLYWOOD INSTALL AFTER GLUED MEMBERS ARE INSTALLED. `\ WOOD 2x ROOF DECK / A / / , 3" ''__ I.5") DIMENSION 0 CUT Sc ATTACH EXISTING PURLINS TO NEW MEMBERS. PROVIDE JOIST HANGERS. ARCHITECT OF RECORD . - 10" / (3) HOLDING ANGLES AT "B" CENTERS / 10" 1 5" J LUMBER 3 -C SECTION SHORE EXIST. FRAMING SIMPSON LUS24 AS REQUIRED. � �i S-1.0 SCALE: NTS 0 SEE DETAIL 3/S-101 FOR CURB ANCHORAGE. I n !��\•i-. -' \ RTU ( Q Q ��_Q z o _ - NOTES: -111iiiiiiiiin \ ' -A I- 7 0 0 \ / / 1. 3/8" X 3/4" NEOPRENE GASKET FOR 2" TO 4" 3-C1 \ / 0 / CHANNELS, OR 3/8" X 1-1/2" NEOPRENE GASKET %= WELD BRACKET TO ROOF S-1.p \ / / FOR CHANNELS 6" AND OVER. �, j Z CURB AT INSTALLATION �J \ / / BBa�B \ / / 2. CURB MAY BE BROKEN DOWN FOR SHIPPING. IN 1 17-1 REINFORCEMENT BRACKET \/ / THESE CASES, FIELD ASSEMBLY WILL BE REQUIRED /\ / BY INSTALLING CONTRACTOR. (2) HOLDING ANGLES / "C" ul \ / 0 \ 1 1/2- x 1 1/2- x 1/8- AT CENTERS / \ / 3. CONTINUOUS BASE SUPPORT TO CURB PANELS, / / INCLUDING THE CENTER SUPPORT PANEL, IS - - CONSULTANTS \ 3-D / REQUIRED. _ _ v_ A �� / 4. DIMENSIONS GIVEN IN INCHES ONLY. �_V ANCHORS TO LAG BOLTS ��BE 3/8" DIA. IN I - - - - AM •„ PENETRATION MIN. 1 In _ s�..' 10' \ CV Sta me c EXISTING PLYWOOD \ 0 01 I 0o ROOF DECK J 10" I_ _I � / /� %Ill/ //// /////// /1 % \ Stantec \ , L0Ji 0 101 0 l 0 I \\ 3" MIN. li 4n N 1 1 1 GRANT AVENUE SUITE 201 � ENDICOTT, NY 13760 Tel. (607)-321-6100 (3---1-- PLAN VIEW (-3-- \ www.stantec.com PROJECT#191001405 WOOD 2xs-1.a SCALE: NTSRTU CURB ANCHORAGE ELEVATION & SECTION (3.7 SECTION DETAIL ...._...,• 0 5-1.0 SCALE: NTS DIMENSION -....._....• LUMBER 0 SCALE: NTS 5-1.0 SCALE: N.T.S. DEVELOPER 1 (2) 111111 4 f__ I — -- I 0 2x8 O _if / . / �, TYP. I 1 EXIST. 2x4 JOISTS1 \ ' AEU PRoFt / / - - - - -- -- - - - - y // I � I `t 85835PE r 13,4,.x 14" I ' I 0 op — 1 f L - - - ( _ _ - _ _ '.61 /7//Ti) / , - / / LVL x 24'-6" I --- O I N 1(2702;16. I I ,� 2 _ - , - _ - - � . ..__ J T -=,, - 1 ...._ _-.. ...... - CC y* •�,OREGON �O 1111, - - / t4O BER B Q� \ I i PORRESS GQ' v I 0 r � )1� V� 'I1�4"x11Y4" LVL x 24' 6" I I \ / - I(2) 2x6 REVISIONS: \ 2 \ , \ I 3200# • 01 1 ISSUE FOR BID/PERMIT 06/06 2017 \� 0 \ 0I o� - / - / \ \ \ 7 2xC- :, - - \ �� 0 0 ' N 1 �:` \ TYPN ,. L - -I 11 \\ - 1 0 1�4 x1 1Y4" LVL x 24 -6 ; / 1- - 1 , RTU-1 I EXIST. 3YY4"x15' . 3600# \ WOOD BEAM 1I \\ \ I ; I \\ I of — I DRAWING BY: <(C/ 1 cnP\ • I DATE: JUNE 06, 2017 \ - T - ___ JOB NUMBER: 2016285.50 U I TITLE: PORTLAND "RENOVATIONS" EXIST. "x26I I STRUCTURAL INSTALLATION k GLULAM BEAM 68 t PARTIAL ROOF PLAN g_. i _ //// I _ _-- --_ _ I _ - I SHEET NUMBER: 2 nF s- i . 0 c `. 12 ii STRUCTURAL INSTALLATION PARTIAL ROOF PLAN c• E S: -"'e o 5-1.0 SCALE: 1/4"=1'-0" N cool MECHANICAL LEGEND AND ABBREVIATIONS PROJECT GENERAL NOTES (ALL ITEMS DO NOT NECESSARILY APPLY) ,CVS 1. THE INTENT OF THE DRAWINGS IS TO PROVIDE A COMPLETE HEATING, VENTILATION, AND AIR NECK SIZE A G AIR CONDITIONING FCU FAN COIL UNIT PD PRESSURE DROP CONDITIONING SYSTEM FOR THE PROPOSED PROJECT. THE SYSTEM PROVIDED SHALL CONFORM TO THE RETURN AIR GRILLE REGISTER / PLANS, DIAGRAM, AND SCHEDULE SHOWN ON THE DRAWINGS. ITEMS OR WORK NOT SHOWN OR CFM TYPE GRILLE/REGISTER POINT OF CONNECTION SPECIFIED, BUT REQUIRED FOR A COMPLETE HEATING, VENTILATION AND AIR CONDITIONING SYSTEM ACH AIR CHANGES PER HOUR QTY QUANTITY SHALL BE PROVIDED AND SHALL CONFORM WITH ACCEPTED TRADE PRACTICES, LOCAL CODES, AND Health NECK SIZE POINT OF DISCONNECTION FH FUME HOOD GOVERNING AUTHORITIES. CRI TYPE SUPPLY AIR DIFFUSER AD ACCESS DOOR RA RETURN AIR AFF ABOVE FINISH FLOOR FLEX FLEXIBLE CONNECTION RAC ROOFTOP AIR CONDITIONING 2. THE DRAWINGS AND SPECIFICATIONS ARE PRESENTED TO DEFINE SPECIFIC SYSTEM REQUIREMENTS AND �E ROUND TO RECTANGULAR !` /\ OPPOSED BLADE DAMPER SERVE TO EXPAND ON THE PRIMARY CONTRACT REQUIREMENTS OF PROVIDING A COMPLETE SYSTEM. DUCT TRANSITION AHU AIR HANDLING UNIT FSD FIRE/SMOKE DAMPER W/ AUTO RESET RH REHEAT THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE ONLY THE GENERAL ARRANGEMENT OF THE ITEMS EXHAUST FAN VD VOLUME DAMPER ALT ALTERNATE FD FIRE DAMPER COMPRISING THE SEVERAL SYSTEMS IN THE HEATING, VENTILATION AND AIR CONDITIONING WORK. (® RHC REHEAT COIL STORE --� FD/FSD D- FIRE DAMPER / ARE SMOKE DAMPER AP ACCESS PANEL FL FLOOR RM ROOM 3. DO NOT SCALE THE DRAWINGS. FIELD VERIFY EXISTING CONDITIONS. INVESTIGATE CONDITIONS �711JfIG . AFFECTING WORK AND INSTALL WORK IN SUCH A MANNER THAT INTERFERENCES BETWEEN PIPES, CORAM, INC. oFAN BD BALANCE DAMPER FPM FEET PER MINUTE RPM REVOLUTIONS PER MINUTE CONDUIT, DUCTS, EQUIPMENT, ARCHITECTURAL AND STRUCTURAL FEATURES SHALL BE AVOIDED. 7358 S W DURHAM RD. 5O DUCT SMOKE DETECTOR BHP BRAKE HORSEPOWER PROVIDE ITEMS THAT MAY BE REQUIRED TO MEET THE CONDITIONS AT THE BUILDING. PORTLAND, OR 97224 FPS FEET PER SECOND SA SUPPLY AIR FFU 2'x4' (FAN FILTER UNIT 4. PROTECT FLOORING FROM DAMAGE DURING CONSTRUCTION PERIOD. PROVIDE APPROPRIATE PROTECTIVE PRO�CTTYPE� W/LIGHT} ♦ DIFFUSER AIR FLOW BOT BOTTOM FVC FUME HOOD VOLUME CONTROLLER SAT SUPPLY AIR TEMPERATURE BARRIER UNDER EQUIPMENT OR MATERIALS STORED ON FLOORS, AND IN AREAS WHERE CONSTRUCTION BTU BRITISH THERMAL UNIT MAY DAMAGE THE FLOOR SURFACES. FLOOR SURFACES INCLUDING SEALERS DAMAGED DURING THE DEAL�s NPR FFU 2'x4' (FAN FILTER UNIT) GAL GALLON CONSTRUCTION SHALL BE REPLACED AT THE COST OF THE CONTRACTOR. I DUCT ELEVATION BRITISH THERMAL CS SCAV SUPPLY CAV BOX FFU 2'x2' (FAN FILTER UNIT) BTUH UNITS PER HOUR GALV GALVANIZED SD SUPPLY AIR DIFFUSER 5. COORDINATE ALL WORK WITH WORK SHOWN ON THE DRAWINGS FOR OTHER TRADES. COORDINATE THE PROJECT 0106369 • DIRECTION OF AIR FLOW GPH GALLON PER HOUR EXACT LOCATION OF THE ROOF TOP UNIT WITH EXISTING CONDITIONS. DUCT UP THRU ROOF CAV CONSTANT AIR VOLUME SFN SUPPLY AIR FAN FLEX CONN. GPM GALLON PER MINUTE \ . --- .1 ARCHITECT OF RECORD SUPPLY AIR DUCT UP CD CONTROL DAMPER SCH SCHEDULE x ' SUPPLY AIR DUCT DOWN a PIPE TURNED UP CFM CUBIC FEET PER MINUTE HP HORSEPOWER SHP SASH HOOD POSITION RETURN AIR DUCT UP a PIPE TURNED DOWN CONN CONNECTION HR HOUR SPEC SPECIFICATION RETURN AIR DUCT DOWN KEY NOTE CONST CONSTRUCTION HVAC HEATING, VENTILATING, SS STAINLESS STEEL c- & AIR CONDITIONING BALANCING PROCEDURE - CLEAN ROOM SUITE CU COPPER HUM HUMIDIFIER TA TRANSFER AIR PRESSURE DIFFERENTIAL 90' ELBOW WITH TURNING VANES 1D SENSOR DAT DISCHARGE AIR TEMPERATURE INSUL INSULATION T.C. TEMPERATURE CONTROL 1. THE INTENT OF THIS SYSTEM IS TO PROVIDE VENTILATION TO THE CLEAN SPACES PER THE FOLLOWING THERMOSTAT KWH KILOWATT HOUR TOS TOP OF STEEL RATES; PREPARATION ROOM AT MORE THAN 20 AIR CHANGES PER HOUR, THE ANTE ROOM AT MORE DDC DIRECT DIGITAL CONTROL THAN 50 AIR CHANGES PER HOUR, AND THE COMPOUNDING ROOM AT MORE THAN 30 AIR CHANGES AxB RECTANGULAR DUCT SIZE LAT LEAVING AIR TEMPERATURE TSP TOTAL STATIC PRESSURE PER HOUR. NPR ANTE ROOM 40 ACH, AND NEG. PRESSURE ROOM 70 ACH. AIR CHANGE RATE MAY BE (INCHES) Cit HUMIDISTAT DEMO DEMOLISH, DEMOLITION HIGHER DUE TO COOLING LOAD. LF LINEAR FEET TSTAT THERMOSTAT A'.0 ROUND DUCT DIA DIAMETER 2. PRESSURIZATION SHALL CASCADE FROM THE COMPOUNDING (CLEAN) ROOM TO THE ANTE AND FROM DUCT WORK SQUARE TO ROUND MAX MAXIMUM V VOLT THE ANTE ROOM TO THE PREPARATION ROOM AND FROM THE PREPARATION ROOM TO THE DN DOWN ROUND TO RECTANGULAR MBH THOUSAND BTU/HR CONSULTANT: VAV VARIABLE AIR VOLUME NON-CLASSIFIED SPACE. PRESSURIZATION FOR NPR SUITE SHALL CASCADE FROM NPR ANTE ROOM TO h DUCT TRANSITION ta\ BUILDING SECTION DP DIFFERENTIAL PRESSURE ( P) D MCC MOTOR CONTROL CENTER VD VOLUME DAMPER NEG. PRESSURE ROOM, PREP ROOM AND SHALL BE GREATER THAN 0.03 IN. W.C. FOR EACH ROOM. DSD DUCT SMOKE DETECTOR 3. PROVIDE FINAL AIR FLOW READINGS AND CERTIFICATION REPORT FOR THE FOLLOWING; Clo -, &MIN MINIMUM VEL VELOCITY Stantec DWG DRAWING • SUPPLY AIR FROM RTU-1 RTU-2. ® MOTORIZED DAMPER i CONTROL DAMPER MA MAKE UP AIR W WATT • RETURN AIR TO RTU-1. EG EXHAUST/RETURN AIR GRILLE G N NORTH WB WET BULB • OUTSIDE AIR TO RTU-1 & RTU-2. EAT ENTERING AIR TEMPERATURE NC NORMALLY CLOSED WC WATER COLUMNtantec DIFFUSER/GRILLE TAG RELIEF AIR FROM RTU-1 Sc& RTU-2 1 1 1 GRANT AVENUE SUITE 201 E DUCT WORK BRANCH TAP ECAV EXHAUST CAV BOX NIC NOT IN CONTRACT VSD VARIABLE FREQUENCY DRIVE • SUPPLY AIR FROM FAN POWERED HEPAs IN EACH ROOM. E=EXHAUST DIFFUSER # ENDICOTT, NY 13760 R=RETURN EF EXHAUST FAN NG NATURAL GAS VP VELOCITY PRESSURE • DIFFERENTIAL PRESSURE ACROSS ALL DOORS FROM ROOM TO ROOM. Tel. (607)-321-6100 S=SUPPLY G=GRILLE XX-XX EL ELEVATION NO NORMALLY OPEN • CLEAN PRESSURE DROP ACROSS EACH HEPA. www.stantec.com PROJECT#191001405 D=DIFFUSER CFM ELEC ELECTRIC (AL) NPR NEGATIVE PRESSURE ROOM • DISCHARGE STATIC PRESSURE FROM RTUs. NTS NOT TO SCALE • RTU STATIC PRESSURE PROFILES. DEVE OCrCLVPER: ESP EXTERNAL STATIC PRESSURE LJrC EXIST EXISTING OA OUTSIDE AIR • RETURN STATIC PRESSURE NEAR RTU-1 . 1 • ROOM VOLUMES AND AIR CHANGE RATES. 4. PROVIDE TEST PLUGS TO CAP ALL DUCT PENETRATIONS WHEN THE TAB WORK IS COMPLETE. 5. AIR CHANGE RATES MAY BE GREATER THAN MINIMUMS DUE TO SPACE COOLING LOADS. 6. BALANCE TO VALUES SHOWN ON THE AIR FLOW DIAGRAM ON DRAWING M-2.0 RTU SCHEDULE IS PROVIDED FOR UNIT SIZING PURPOSES. ) SEAL _ S` COMMISSIONING - CLEAN ROOM SUITE ADA REQUIREMENTf?. t� �G�NFF GENERAL DEMOLITION NOTES e . .- "- UPON COMPLETION, REVIEW AND APPROVAL OF THE FINAL TESTING AND BALANCING OF THE HVAC SYSTEM, �%� .., OREGON THE CONTRACTOR SHALL COMMISSION THE CLEAN ROOM SYSTEM, INCLUDING BUT NOT LIMITED TO: 1. SCHEDULE DEMOLITION WORK WITH THE OWNER. OWNER'S PLANT MAINTENANCE STAFF SHALL BE 'PN RESPONSIBLE FOR SYSTEM SHUTDOWNS. 441FR7J Gl 1 . COMPLETE CLEANING AND DISINFECTION OF ALL HVAC ELEMENTS IN CONTACT WITH AIR DELIVERED TO / TOP THE CLEAN ROOM SUITE. OF / 24" MAX. /- % 2. WHERE DRAWINGS INDICATE DEMOLITION OF EXISTING PIPING, DUCTWORK, AND OTHER MECHANICAL 2. REVIEW AND RECORD THE PRESSURE DROP ON ALL FILTER ELEMENTS. THERMOSTAT, EQUIPMENT, SUCH SERVICES SHALL BE PROPERLY TERMINATED IN AN APPROVED MANNER TO ALLOW 'EXPIRATION DATE;/-, :,7't SWITCH, +i / TOP AFFECTED SYSTEMS TO REMAIN IN OPERATION. 3. OPERATIONAL CONFIRMATION OF THE HVAC SYSTEM, INCLUDING, OUTLET, _ OF CONTROL a ¢o THERMOSTAT, a. HEATING. Q ,_ SWITCH, 3. IN SOME CASES, EXISTING CONDITIONS ARE SHOWN ON DEMOLITION DRAWINGS IN AREAS REQUIRING REVISIONS: // Q < OUTLET, NO DEMOLITION. IN SUCH CASES, INFORMATION IS PROVIDED FOR REFERENCE ONLY. b. COOLING. / o o CONTROL Q ISSUE FOR BID/PERMIT 06/06/2017 c. DEHUMIDIFICATION. E 4. EQUIPMENT INDICATED FOR REMOVAL SHALL BE REVIEWED BY THE OWNER. REMOVE EQUIPMENT THE d. MAINTENANCE OF REQUIRED AIR CHANGE. _ ' OWNER WISHES TO RETAIN AND DELIVER TO LOCATION DESIGNATED BY OWNER. REMOVE PROMPTLY FROM SITE MATERIALS AND EQUIPMENT INDICATED FOR REMOVAL WHICH ARE NOT SPECIFIED FOR e. MAINTENANCE OF REQUIRED PRESSURE DIFFERENTIAL. ~' I REUSE, STORAGE, OR RETAINAGE BY OWNER. la FINISHED '� - FINISHED FLOOR d- FLOOR J / ' /,, ` - / - 5. STORE OFF-SITE EXISTING EQUIPMENT TO BE REUSED PRIOR TO INSTALLATION. ALL NEW DEVICES, OUTLETS, SWITCHES, CONTROLS, ETC. SHALL BE INSTALLED WITH CONCERN FOR ALIGNMENT WITH WORK OF OTHER TRADES. PROVIDE VERTICAL AND HORIZONTAL ALIGNMENT WITH 6. CONTRACTOR SHALL VERIFY THAT ANY SERVICE OR SYSTEM TO BE REMOVED IS NOT REQUIRED EQUAL SPACING BETWEEN CENTER LINES. IF DOCUMENTS DO NOT INDICATE ALIGNMENT AND/OR WITHIN OR OUTSIDE OF THE AREA PRESENTLY UNDER CONSTRUCTION. SPACING CONSULT WITH ARCHITECT PRIOR TO ROUGH IN. 7. THE CONTRACTOR SHALL TAKE CARE TO DEMOLISH ONLY THAT WORK WHICH IS REQUIRED TO BE DEMOLISHED AND NOT TO DISTURB ANY WORK WHICH IS TO REMAIN. IF, IN THE COURSE OF DEMOLITION, THE CONTRACTOR DESTROYS ANY WORK WHICH IS TO REMAIN, THE CONTRACTOR SHALL CLEAN ROOM CLASSIFICATIONS REPAIR OR REPLACE, AS NECESSARY, SUCH WORK AT THE CONTRACTOR'S EXPENSE. cr at 77 CONTRACTOR SHALL INSTALL ALL COMPONENTS AND SYSTEMS TO MEET THE LATEST USP 797 STANDARDS 8. IN THE EVENT THAT DEMOLITION WORK EFFECTS THE STRUCTURAL SUPPORT OF EXISTING MECHANICAL DRAWING BY: a AND APPLICABLE CODES. CLEAN ROOM SUITE TO BE CERTIFIED AS FOLLOWS: SYSTEMS THAT ARE TO REMAIN AND ARE NOT PART OF THE DEMOLITION WORK, THE CONTRACTOR m SHALL PROVIDE SUPPORTS FOR EXISTING MECHANICAL SYSTEMS TO REMAIN IN MANNER APPROVED DATE: JUNE Ofi, 2017 01 1. COMPOUNDING (CLEAN) ROOM: ISO 7 BY THE OWNER AND IN ACCORDANCE WITH APPLICABLE CODES. 3 2. COMPOUNDING ANTE ROOM: ISO 8 = 3. PREP ROOM: ISO 8 9. PROVIDE SUPPORT AS REQUIRED FOR ANY EXISTING DUCTWORK, PIPING AND MECHANICAL EQUIPMENT JOB NUMBER: 2016285.50 a 4. EDGEGARD HOODS: ISO 5 WHOSE EXISTING SUPPORT IS AFFECTED BY GENERAL DEMOLITION. i P 5. NPR ANTE ROOM: ISO 8 TITLE: PORTLAND "RENOVATIONS" 6. NEGATIVE PRESSURE ROOM: ISO 7 ✓ U 7. BIO-SAFETY CABINETS: (ISO 5) NSF CLASS II, TYPE A2. 10. DEMOLITION OF EXISTING PIPING SHALL INCLUDE CAPPING OF PIPING BELOW FLOORS OR IN WALLS MECHANICAL o . REMOVED BACK WHERE AATN THE LAST POINT IS BEING T OFD CONTINUING SERVICE. ANY PIPING NO D TO MINIMIZE ABANDONEDNGER REQUIRED SHALL LEAD SHEET N PIPING. mg I SHEET NUMBER: o g,ip. M-0 . 1 E51 II C'M N E TS..._...._.�-.._.`..�v._...v A Em II II 2 r�i r i c `` GENERAL REQUIREMENTS (APPLICABLE TO ALL TRADES) GENERAL NOTES MECHANICAL GENERAL NOTES FAN FILTER UNIT(FFU)SPEED CONTROLS WORK COVERED BY CONTRACT DOCUMENTS REQUESTS FOR INFORMATION (RFI'S) 1. CONTRACTOR IS RESPONSIBLE FOR VISITING THE PROJECT SITE TO VERIFY EXISTING PROVIDE ENVIRCO MULTI CHANNEL SPEED CONTROLLER: CONDITIONS PRIOR TO SUBMITTING THE BID. THE CONTRACTOR SHALL FURNISH ALL MATERIAL, LABOR, EQUIPMENT,TOOLS,SUPERVISION, ETC. GENERAL: IMMEDIATELY ON DISCOVERY OF THE NEED FOR ADDITIONAL INFORMATION OR • COORDINATE WITH THE MANUFACTURER, INSTALLATION INSTRUCTIONS AND ENVIRCO-DWG TITLE: TO COMPLETE THE WORK AS SHOWN AND IMPLIED BY THE CONTRACT DOCUMENTS FOR TESTED, INTERPRETATION OF THE CONTRACT DOCUMENTS,CONTRACTOR SHALL PREPARE AND SUBMIT AN 2. VERIFY EXISTING CEILING SYSTEM WHERE BEING PARTIALLY MAINTAINED. LIGHTS AND FAN CVS CONTROL SCHEMATIC 001 I DWG#-CVS-001 (LMG) Health . • APPROVED AND OPERATIONAL FACILITIES/IMPROVEMENTS. RFI IN THE FORM SPECIFIED. FILTER UNITS(FFU'S)ARE BEING REPLACED. GRID LAYOUT MODULE AND GRID TYPE AND • PROVIDE LOCKABLE TRANSPARENT WALL MOUNT ENCLOSURE. - ENGINEER WILL RETURN RFI'S SUBMITTED TO ENGINEER BY OTHER ENTITIES CONTROLLED PROFILE MUST BE IDENTIFIED AND COORDINATED WITH THE CVS STANDARD FFU, ENVIRCO PROVIDE RECORD DOCUMENTATION FOR ALL FFUS: WORK UNDER SEPARATE CONTRACTSBY CONTRACTOR WITH NO RESPONSE MAC10 2x4 LEDC RSR/RSRE(ROOM SIDE REPLACEABLE FILTER AND MOTOR), SIZE 23.63"x • RETAIN THE"CERTIFICATE OF CONFORMANCE"ON DELIVERY AND PROVIDE TO CVS REGIONAL COORDINATE AND SUBMIT RFI'S(N A PROMPT MANNER SO AS TO AVOID DELAYS IN 47.63"X 16.43"H.ADJUST GRID LAYOUT AS REQUIRED TO ACCOMMODATE ELECTRICAL AND • FACILITY MANAGER AS SUBMITTAL. COOPERATE FULLY WITH SEPARATE CONTRACTORS SO WORK ON THOSE CONTRACTS MAY BE CONTRACTOR'S WORK OR WORK OF SUBCONTRACTORS MECHANICAL INSTALLATION. PROVIDE NEW GRID AND TILE AS REQUIRED. • RECORD BOTH THE FFU SERIAL NUMBER,HEPA FILTER SERIAL NUMBER AND CONTROLLER STORE MEER CARRIED OUT SMOOTHLY,WITHOUT INTERFERING WITH OR DELAYING WORK UNDER THIS CONTENT OF RFI: INCLUDE A DETAILED, LEGIBLE DESCRIPTION OF ITEM NEEDING INFORMATION OR ADDRESS. • CONTRACT OR OTHER CONTRACTS.COORDINATE THE WORK OF THIS CONTRACT WITH WORK 3. VERIFY EXISTING CLEANROOM PARTITION SYSTEM FOR DOOR AND WINDOW REPLACEMENTS. CORAM, INC. INTERPRETATION AND THE FOLLOWING: 7358 S W DURHAM RD. PERFORMED UNDER SEPARATE CONTRACTS. THE INTENT IS FOR THE FINAL INSTALLATION OF DOORS, FRAMES,WINDOW FRAMES,AND - PROJECT NAME. SEISMIC BRACING PROJECT NUMBER. GLASS TO BE FLUSH WITH THE CLEANROOM WALL FINISH. FRAMES TO BE SEAMLESS,WITH A- PORTLAND, OR 97224 OWNER-FURNISHED PRODUCTS - DATE. FLUSH AND SMOOTH TRANSITION TO THE ADJACENT WALL FINISH. REPLACEMENT OF DOORS (FOR ALBUQUERQUE,GOLETA, HAYWARD, HENDERSON, LOS ANGELES, MURRAY, NASHVILLE, - NAME OF CONTRACTOR. WITH THE TWO-PIECE CLAMSHELL FRAME WILL REQUIRE ADVANCE OPENING MEASUREMENTS PORTLAND,SAN ANTONIO,SAN DIEGO&ST. LOUIS) PROJECT TYPE PHARMACY NAME OF OWNER. AND PRE-ORDER.APPROXIMATELY 9 WEEKS LEAD TIME ON THE ASI 220.WINDOW SECURELY FASTEN ALL PIPING AND DUCTWORK WITHIN STRUCTURES TO THE BUILDING CONSTRUCTION DEAL WILL FURNISH PRODUCTS INDICATED.THE WORK INCLUDES RECEIVING, UNLOADING, REPLACEMENTS SHOULD BE COORDINATED SIMILARLY. TYPE PM HANDLING, STORING, PROTECTING,AND INSTALLING OWNER FURNISHED PRODUCTS AND - RFI NUMBER, NUMBERED SEQUENTIALLY. BY MEANS OF HANGERS, SUPPORTS,GUIDES,ANCHORS AND SWAY BRACES TO MAINTAIN PIPE AND INTEGRATING INTO THE PROJECT TO MAKE IT A FULLY FUNCTIONING SYSTEM. - RFI SUBJECT. DUCTWORK ALIGNMENT,4. THE INTENT IS TO CLEAN AND SEAL ALL VOIDS IN THE CEILING PLENUM WALLS AND ROOF TO PIPING AND DUCTWORK DUDE TO MOVEMENT PREVENT UNDER NG AND TO PREVENT NOISE EXCESSIVE STRAIN ON NUMBER SPECIFICATION TITLE AND RELATED PARAGRAPHS,AS APPROPRIATE. UNDER O ERAT NG CONDITIONS. Cg PROJECT ER 0106369 . TYPICALLY OWNER-FURNISHED PRODUCTS (VERIFY WITH DRAWING SET): - DRAWING NUMBER AND DETAIL REFERENCES,AS APPROPRIATE. PRODUCE AN AIRTIGHT SPACE.ALL UNPAINTED/UNCOATED MATERIAL SHALL BE PREPARED SUPPORTS FOR ALL PIPING AND DUCTWORK SHALL BE IN ACCORDANCE WITH THE LATEST SMACNA - ROOFTOP AIR HANDLING UNITS. - FIELD DIMENSIONS AND CONDITIONS,AS APPROPRIATE. AND PAINTED TO ENSURE NO SHEDDABLE MATERIAL COULD BECOME AIRBORNE.CONDITIONS GUIDELINES FOR SEISMIC RESTRAINTS OF MECHANICAL SYSTEMS(OSHPD EDITION IN CALIFORNIA)OR - HEPA FAN FILTER UNITS. - CONTRACTOR'S SUGGESTED RESOLUTION. SUCH AS EXPOSED RUST,CHIPPED PAINT,OXIDIZED METAL SHOULD BE INSPECTED AND OTHER SUCH GUIDANCE AS DIRECTED BY THE AUTHORITY HAVING JURISDICTION. ARCHITECT OF RECORD - PASS-THROUGHS. - CONTRACTORS SIGNATURE. TREATED APPROPRIATELY WHILE THE CEILING BELOW IS"OPEN".THE FINAL INSTALLATION - ATTACHMENTS: INCLUDE SKETCHES,DESCRIPTIONS, MEASUREMENTS, PHOTOS, PRODUCT WILL INCLUDE HOLD DOWN CLIPS AND COMPLETELY SEALING EVERY CEILING TILE TO THE GRID - DATA,SHOP DRAWINGS,COORDINATION DRAWINGS,AND OTHER INFORMATION NECESSARY TO MAKE THE PLENUM SPACE INACCESSIBLE. ELECTRIC DUCT REHEAT COILS TO FULLY DESCRIBE ITEMS NEEDING INTERPRETATION. GENERAL: — INCLUDE DIMENSIONS,THICKNESSES, STRUCTURAL GRID REFERENCES,AND DETAILS OF 5. THE SPACE INSIDE THE PLENUM NEEDS TO BE INSPECTED FOR PAINTING REQUIREMENTS.ANY 1. DUCT HEATERS SHALL BE INDEECO AFFECTED MATERIALS,ASSEMBLIES,AND ATTACHMENTS ON ATTACHED SKETCHES. UNFINISHED MATERIALS NEED TO BE CLEANED, PREPARED AND PAINTED.IF RUST,OXIDATION a. TYPE QUZ STANDARD FLANGED HEATERS (WHITE RUST),CHIPPED FINISHES ARE DISCOVERED,THEN THOSE MATERIALS ARE TO BE WORK RESTRICTIONS RFI FORMS:SOFTWARE-GENERATED FORM WITH SUBSTANTIALLY THE SAME CONTENT AS CLEANED,PREPARED AND PAINTED. 2. APPROVALS: HEATERS AND PANELBOARDS SHALL MEET THE REQUIREMENTS OF THE NATIONAL INDICATED ABOVE,ACCEPTABLE TO THE ENGINEER. ELECTRICAL CODE AND SHALL BE LISTED BY UNDERWRITERS LABORATORIES FOR ZERO WORK RESTRICTIONS,GENERAL: COMPLY WITH RESTRICTIONS ON CONSTRUCTION OPERATIONS. - ATTACHMENTS SHALL BE ELECTRONIC FILES IN ADOBE ACROBAT PDF FORMAT. 6. IF RUST OR CHIPPED PAINT IS DISCOVERED ON A STEEL BEAM OR PIPE,THEN THE ENTIRE CLEARANCE TO COMBUSTIBLE SURFACES AND FOR USE WITH HEAT PUMPS AND AIR - BUILDING AND CLEANROOM OPERATIONS AND WITH OTHER REQUIREMENTS OF LANDLORD CONDITIONING EQUIPMENT. INSTALLATION BEAM OR PIPE SYSTEM EXPOSED IN THE PLENUM SHOULD BE PAINTED. IF OXIDATION OR AND CVS. UNFINISHED GALVANIZED METAL DECK IS DISCOVERED,THEN THE ENTIRE UNDERSIDE OF THE 3. HEATING ELEMENTS SHALL BE OPEN COIL, 80% NICKEL,20%CHROMIUM, GRADE A RESISTANCE USE OF SITE: LIMIT USE OF PROJECT SITE TO WORK IN AREAS WITHIN THE CONTRACT LIMITS METAL DECK NEEDS TO BE PAINTED. NO SPOT OR TOUCH UP PAINTING WOULD BE WIRE.TYPE C ALLOYS CONTAINING IRON OR OTHER ALLOYS ARE NOT ACCEPTABLE.COILS INDICATED. GENERAL: LOCATE THE WORK AND COMPONENTS OF THE WORK ACCURATELY, IN CORRECT ACCEPTABLE.THE ENTIRE SURFACE OF THE MATERIAL OR SYSTEM EXPOSED IN THE PLENUM SHALL BE MACHINE CRIMPED INTO STAINLESS STEEL TERMINALS EXTENDING AT LEAST 1-INCH - DRIVEWAYS,WALKWAYS AND ENTRANCES: KEEP DRIVEWAYS AVAILABLE TO OWNER, ALIGNMENT AND ELEVATION,AS INDICATED. SHOULD BE PAINTED. ITEMS NOT TO BE PAINTED INCLUDE LIGHTS,HEPA FAN FILTER UNITS, INTO THE AIRSTREAM AND ALL TERMINAL HARDWARE SHALL BE STAINLESS STEEL. COILS OWNER'S EMPLOYEES,AND EMERGENCY VEHICLES AT ALL TIMES. DO NOT USE THESE AREAS - MAKE VERTICAL WORK PLUMB AND MAKE HORIZONTAL WORK LEVEL. LABELS, FRP FINISHES OR TRIM, PLASTIC OR MYLAR FACINGS OR FINISHES. SHALL BE SUPPORTED BY CERAMIC BUSHINGS STAKED INTO SUPPORTING BRACKETS. FOR PARKING OR STORAGE OF MATERIALS. - WHERE SPACE IS LIMITED, INSTALL COMPONENTS TO MAXIMIZE SPACE AVAILABLE FOR 4. HEATER FRAMES AND TERMINAL BOXES SHALL BE CORROSION RESISTANT STEEL. UNLESS - SCHEDULE DELIVERIES TO MINIMIZE USE OF DRIVEWAYS AND ENTRANCES BY MAINTENANCE AND EASE OF REMOVAL FOR REPLACEMENT. 7. ALL CLEANING, PREPARATION AND PAINTING IS TO BE DONE PER THE PAINT MANUFACTURER'S OTHERWISE INDICATED,THE TERMINAL BOX SHALL BE NEMA 1 CONSTRUCTION AND SHALL BE CONSTRUCTION OPERATIONS. - CONCEAL PIPES, DUCTS,AND WIRING IN FINISHED AREAS UNLESS OTHERWISE INDICATED. SPECIFICATIONS AND RECOMMENDATIONS.THE PRODUCTS SPECIFIED ON THE DRAWINGS ARE PROVIDED WITH A HINGED, LATCHING COVER AND MULTIPLE CONCENTRIC KNOCKOUTS FOR CONSULTANT: — SCHEDULE DELIVERIES TO MINIMIZE SPACE AND TIME REQUIREMENTS FOR STORAGE OF TO BE USED. FIELD WIRING. MATERIALS AND EQUIPMENT ON-SITE. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS AND RECOMMENDATIONS FOR NOISE,VIBRATION AND ODORS:COORDINATE OPERATIONS THAT MAY RESULT IN HIGH LEVELS OF INSTALLING PRODUCTS IN APPLICATIONS INDICATED. \' „, 1 5. ALL HEATERS SHALL BE FURNISHED WITH A DISC TYPE,AUTOMATIC RESET THERMAL CUTOUT , NOISE AND VIBRATION, ODORS, OR OTHER DISRUPTION TO BUILDING OCCUPANTS WITH OWNER. FOR PRIMARY OVER-TEMPERATURE PROTECTION.ALL HEATERS SHALL ALSO BE FURNISHED iii,‘,„ s .,. INSTALL PRODUCTS AT THE TIME AND UNDER CONDITIONS THAT WILL ENSURE THE BEST POSSIBLEWITH DISC TYPE, LOAD CARRYNG MANUAL RESET THERMAL CUTOUTS, FACTORY WIRED IN 2WORKING HOURS: WORKING HOURS ARE MONDAY THROUGH FRIDAY AS DEFINED BY THE LOCAL RESULTS. MAINTAIN CONDITIONS REQUIRED FOR PRODUCT PERFORMANCE UNTIL SUBSTANTIAL SERIES WITH HEATER STAGES FOR SECONDARY PROTECTION. HEAT LIMITERS OR OTHER y - CVS CORAM BRANCH HOURS. COMPLETION. FUSIBLE OVER-TEMPERATURE DEVICES ARE NOT ACCEPTABLE. a ; atec 6. HEATERS SHALL BE RATED FOR THE VOLTAGE, PHASE,AND NUMBER OF HEATING STAGES CONTRACTOR MAY REQUEST TO WORK EXTENDED HOURS OR ON WEEKENDS WITH PRIOR CONDUCT CONSTRUCTION OPERATIONS SO NO PART OF THE WORK IS SUBJECTED TO DAMAGING INDICATED IN THE SCHEDULE.ALL THREE-PHASE HEATERS SHALL HAVE EQUAL, BALANCED, Stantec APPROVAL FROM CVS TO MAINTAIN SCHEDULE. OPERATIONS OR LOADING IN EXCESS OF THAT EXPECTED DURING NORMAL CONDITIONS OF THREE-PHASE STAGES.ALL INTERNAL WIRING SHALL BE STRANDED COPPER WITH 105°C 111 GRANT AVENUE SUITE 201 OCCUPANCY. INSULATION AND SHALL BE TERMINATED IN CRIMPED CONNECTORS OR BOX LUGS. SUBSTITUTION PROCEDURES 7. TERMINAL BLOCKS SHALL BE PROVIDED FOR ALL FIELD WIRING AND SHALL BE SIZED FOR ENDICOTT, NY 13760 SUBSTITUTIONS FOR CAUSE:CHANGES PROPOSED BY CONTRACTOR THAT ARE REQUIRED DUE TO SEQUENCE THE WORK AND ALLOW ADEQUATE CLEARANCES TO ACCOMMODATE MOVEMENT OF INSTALLATION OF 75°C COPPER WIRE RATED IN ACCORDANCE WITH NEC REQUIREMENTS. Tel. (607)-321-6100 CHANGED PROJECT CONDITIONS, SUCH AS UNAVAILABILITY OF PRODUCT,REGULATORY CHANGES, CONSTRUCTION ITEMS ON SITE AND PLACEMENT IN PERMANENT LOCATIONS. 8. HEATERS SHALL BE FURNISHED, EITHER WITH THE CONTROL OPTION SPECIFIED IN THE www.stantec.com PROJECT#191001405 OR UNAVAILABILITY OF REQUIRED WARRANTY TERMS. SCHEDULE AND DESCRIBED BELOW, OR WITH THE SPECIFIC COMPONENTS LISTED IN THE ATTACHMENT: PROVIDE BLOCKING AND ATTACHMENT PLATES AND ANCHORS AND FASTENERS OF SCHEDULE. SUBSTITUTIONS FOR CONVENIENCE: CHANGES PROPOSED BY CONTRACTOR OR OWNER THAT ARE ADEQUATE SIZE AND NUMBER TO SECURELY ANCHOR EACH COMPONENT IN PLACE,ACCURATELY NOT REQUIRED IN ORDER TO MEET OTHER PROJECT REQUIREMENTS BUT MAY OFFER ADVANTAGE LOCATED AND ALIGNED WITH OTHER PORTIONS OF THE WORK.WHERE SIZE AND TYPE OF a. OPTION K-THERMAL CUTOUTS,AIRFLOW SWITCH,CONTACTORS(WHERE REQUIRED), SCR DEVELOPER: TO CONTRACTOR OR OWNER. ATTACHMENTS ARE NOT INDICATED,VERIFY SIZE AND TYPE REQUIRED FOR LOAD CONDITIONS. SI(WNGLE PHASE)TH STEP �FUSES (IF R IOVER 48 AMPSF HEATER ),CONTROL CIRCUIT TRANSFORMES OVER 96 AMPS THREE-PHASE OR,AND R 192 MPS MOUNTING HEIGHTS:WHERE MOUNTING HEIGHTS ARE NOT INDICATED, MOUNT SUBSTITUTION REQUESTS:SUBMIT THREE COPIES OF EACH REQUEST FOR CONSIDERATION. COMPONENTS AT HEIGHTS DIRECTED BY ENGINEER. BUILT-IN SNAP-ACTING DOOR INTERLOCKED DISCONNECT SWITCH. IDENTIFY PRODUCT OR FABRICATION OR INSTALLATION METHOD TO BE REPLACED. INCLUDE 9. WHEN SPECIFIED IN THE SCHEDULE, OR BELOW, HEATERS WILL BE SUPPLIED WITH THE SPECIFICATION TITLE AND DRAWING NUMBERS AND TITLES. JOINTS: MAKE JOINTS UNIFORM WIDTH.WHERE JOINT LOCATIONS IN EXPOSED WORK ARE NOT FOLLOWING SPECIAL FEATURES: - DOCUMENTATION:SHOW COMPLIANCE WITH REQUIREMENTS FOR SUBSTITUTIONS AND THE INDICATED,ARRANGE JOINTS FOR BEST VISUAL EFFECT. FIT EXPOSED CONNECTIONS TOGETHER a. INSULATED TERMINAL BOX FOLLOWING,AS APPLICABLE. TO FORM HAIRLINE JOINTS. b. TRANSFORMER SECONDARY FUSING(CLASS II) — STATEMENT INDICATION WHY SPECIFIED PRODUCT OR FABRICATION OR INSTALLATION HAZARDOUS MATERIALS: USE PRODUCTS,CLEANERS,AND INSTALLATION MATERIALS THAT ARE c. STEP CONTROLLER CANNOT BE PROVIDED, IF APPLICABLE. NOT CONSIDERED HAZARDOUS. — COORDINATION INFORMATION, INCLUDING A LIST OF CHANGES OR REVISIONS NEEDED 10. WHEN SPECIFIED IN THE SCHEDULE,OR BELOW,HEATERS SHALL BE SUPPLIED WITH THE TO OTHER PARTS OF THE WORK AND TO CONSTRUCTION PERFORMED BY SEPARATE PROGRESS CLEANING FOLLOWING THERMOSTATS: CONTRACTORS THAT WILL BE NECESSARY TO ACCOMMODATE PROPOSED a. PROPORTIONAL ELECTRONIC ROOM THERMOSTAT SUBSTITUTION. GENERAL: CLEAN PROJECT SITE AND WORK AREAS DAILY, INCLUDING COMMON AREAS. ENFORCE '', — DETAILED COMPARISON OF SIGNIFICANT QUALITIES OF PROPOSED SUBSTITUTION WITH REQUIREMENTS STRICTLY. DISPOSE OF MATERIALS LAWFULLY. THOSE OF THE WORK SPECIFIED.SIGNIFICANT QUALITIES MAY INCLUDE ATTRIBUTES SEAL: SUCH AS PERFORMANCE,WEIGHT, SIZE, DURABILITY,VISUAL EFFECT, SUSTAINABLE SITE: MAINTAIN PROJECT SITE FREE OF WASTE MATERIALS AND DEBRIS. DESIGN CHARACTERISTICS,WARRANTIES,AND SPECIFIC FEATURES AND REQUIREMENTS Y3�""PROFS INDICATED. INDICATE DEVIATIONS , IF ANY, FROM THE WORK SPECIFIED. WORK AREAS:CLEAN AREAS WHERE WORK IS IN PROGRESS TO THE LEVEL OF CLEANLINESS end;N'FE`' — PRODUCT DATA, INCLUDING DRAWINGS AND DESCRIPTIONS OR PRODUCTS AND NECESSARY FOR PROPER EXECUTION OF THE WORK. 4e r_-- 1 _ FABRICATION AND INSTALLATION PROCEDURES. - REMOVE LIQUID SPILLS PROMPTLY. — SAMPLES,WHERE APPLICABLE OR REQUESTED. - WHERE DUST WOULD IMPAIR PROPER EXECUTION OF THE WORK,VACUUM THE ENTIRE � !ter — CERTIFICATES AND QUALIFICATION DATA,WHERE APPLICABLE OR REQUESTED. WORK AREA,AS APPROPRIATE. .,.0.70"' '_EGON — MATERIAL TEST REPORTS FROM A QUALIFIED TESTING AGENCY INDICATING AND ,p It INTERPRETING TEST RESULTS FOR COMPLIANCE WITH REQUIREMENTS INDICATED. INSTALLED WORK:KEEP INSTALLED WORK CLEAN.CLEAN INSTALLED SURFACES ACCORDING TO 9 G�'' -- DETAILED COMPARISON OF CONTRACTOR'S CONSTRUCTION SCHEDULE USING WRITTEN INSTRUCTIONS OF MANUFACTURER OR FABRICATOR OF PRODUCT INSTALLED, USING '' PROPOSED SUBSTITUTION WITH PRODUCTS SPECIFIED FOR THE WORK, INCLUDING ONLY CLEANING MATERIALS SPECIFICALLY RECOMMENDED. IF SPECIFIC CLEANING MATERIALS ARE EFFECT ON THE OVERALL CONTRACT TIME. IF SPECIFIED PRODUCT OR METHOD OF NOT RECOMMENDED, USE CLEANING MATERIALS THAT ARE NOT HAZARDOUS TO HEALTH OR !EXPIRATION DATE; CONSTRUCTION CANNOT BE PROVIDED WITHIN THE CONTRACT TIME, INCLUDING LETTER PROPERTY AND THAT WILL NOT DAMAGE EXPOSED SURFACES. FROM MANUFACTURER, ON MANUFACTURER'S LETTERHEAD,STATING DATE OF RECEIPT OF PURCHASE ORDER, LACK OF AVAILABILITY,OR DELAYS IN DELIVERY. CONCEALED SPACES: REMOVE DEBRIS FROM CONCEALED SPACES BEFORE ENCLOSING THE — COST INFORMATION. SPACE. — CONTRACTOR'S CERTIFICATION THAT PROPOSED SUBSTITUTION COMPLIES WITH REVISIONS: REQUIREMENTS IN THE CONTRACT DOCUMENTS EXCEPT AS INDICATED IN SUBSTITUTION EXPOSED SURFACES IN FINISHED AREAS: CLEAN EXPOSED SURFACES AND PROTECT AS REQUEST, IS COMPATIBLE WITH RELATED MATERIALS,AND IS APPROPRIATE FOR NECESSARY TO ENSURE FREEDOM FROM DAMAGE AND DETERIORATION AT TIME OF SUBSTANTIAL A ISSUE FOR BID/PERMR 06/06/2017 APPLICATIONS AS INDICATED. COMPLETION. PROJECT SCHEDULE PROJECT SCHEDULE:WITHIN 48 HOURS OF PROJECT AWARD,CONTRACTOR SHALL SUBMIT A CONSTRUCTION PROJECT SCHEDULE, IN A GENERALLY ACCEPTED FORMAT SUCH AS GANTT CHART,TO PROVIDE SPECIFICS ON WORK ACTIVITIES AND PHASING TO ALLOW FOR MONITORING OF PROGRESS. \" J 3t - SUITE NIT /� OF OPERATION "RTU-2"- NEC. PRESSURE RM UNIT DRAWING BY: 5 SEQUENCE OF OPERATION "RTU-1 " CLEAN ROOM U SEQUENCE t RTU-1 SHALL OPERATE AS FOLLOWS: RTU-2 SHALL OPERATE AS FOLLOWS: DATE: JUNE 06, 2017 1. UNIT SHALL BE RUN CONTINUOUSLY. THE DISCHARGE TEMPERATURE FROM THE AIR HANDLER SHALL 1. UNIT SHALL BE RUN CONTINUOUSLY. THE DISCHARGE TEMPERATURE FROM THE AIR HANDLER SHALL BE JOB NUMBER: 2016285.50 a BE MAINTAINED AT A SETPOINT OF 55"F (ADJUSTABLE). MODULATED AS NEEDED TO MAINTAIN AT A SETPOINT OF 65"F (ADJUSTABLE) AS SENSED BY THE ROOM WI 8 2. UPON A CALL FOR DEHUMIDIFICATION, AS SENSED BY THE ROOM HUMIDITY SENSOR LOCATED IN THE TEMPERATURE SENSOR LOCATED IN THE COMPOUNDING (CLEAN) ROOM. TITLE: PORTLAND RENOVATIONS COMPOUNDING (CLEAN) ROOM, THE DX SYSTEM SHALL BE ENERGIZED AND STAGED ON TO MAINTAIN r `' THE ROOM RELATIVE HUMIDITY AT 50% (ADJ.). THE SUPPLY AIR SHALL BE SUB-COOLED BELOW 55 2. UPON A CALL FOR DEHUMIDIFICATION, AS SENSED BY THE ROOM HUMIDITY SENSOR LOCATED IN THE MECHANICAL t• - s € NEGATIVE PRESSURE ROOM, THE DX SYSTEM SHALL BE ENERGIZED AND STAGED ON TO MAINTAIN THE GENERAL NOTES 'F AND THEN REHEATED BY THE ELECTRIC REHEAT COIL AS REQUIRED. �'' � ROOM RELATIVE HUMIDITY AT 50% (ADJ.). THE SUPPLY AIR SHALL BE SUB-COOLED BELOW 55 "F AND ^c� 3. UPON A CALL FOR HEATING FROM ANY OF THE SPACE SENSORS, THE ELECTRIC REHEAT COIL FOR THEN REHEATED BY THE ELECTRIC REHEAT COIL AS REQUIRED. • S THAT SPACE SHALL MODULATE WITH SCR CONTROL TO MAINTAIN THE ROOM TEMPERATURE AT 65"F SHEET NUMBER: � g (ADJUSTABLE). 3. HOOD EXHAUST FANS SHALL RUN CONTINUOUSLY. REMOTELY ACTUATED BUBBLE TIGHT DAMPERS SHALL • M-O .2 BE PROVIDED FOR EMERGENCY USE. THEY SHALL BE ELECTRICALLY ACTUATED TO OPEN, SPRING TO FAIL Y l 5. ,..... } ,....,.. CLOSED AND OPERATED FROM ILLUMINATED WALL SWITCHES WITHIN THE COMPOUNDING (CLEAN) ROOM. ill N N g - _ - - PACKAGED ROOF TOP UNIT GENERAL MECHANICAL SPECIFICATIONS �°�-- E - OWNER WILL PRE-PURCHASE ROOF TOP UNIT AND CURB. THIS CONTRACT SHALL RECEIVE, STORE, AND INSTALL UNIT. 1• METAL DUCTS A. SINGLE-WALL RECTANGULAR DUCTS AND FITTINGS Health PART 1 - GENERAL a. SHEET METAL: EXCEPT AS OTHERWISE INDICATED, FABRICATE DUCTWORK FROM GALVANIZED SHEET STEEL COMPLYING WITH ANSI/ASTM A 527, LOCKFORMING QUALITY, WITH 1.1 RELATED DOCUMENTS ANSI/ASTM A 525, G90 ZINC COATING, MILL PHOSPHATIZED FOR EXPOSED LOCATIONS. A. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS APPLY TO THIS SECTION. b. APPLICABLE LEAKAGE CLASSES: DUCTWORK SHALL BE RATED FOR SEAL CLASS "A". ALL JOINTS, SEAMS AND CEILING / WALL PENETRATIONS ARE TO BE SEALED. 1.2 SUMMARY c STATIC-PRESSUREENERAL FABRICATION ABICA ION REQUIREMENTS: COMPLY WITH SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE" BASED ON LOW STORE A. THIS SECTION INCLUDES CUSTOM PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS (ROOFTOP UNITS) WITH THE FOLLOWING COMPONENTS ANDVOREG • ACCESSORIES: d. TRANSVERSE JOINTS: SELECT JOINT TYPES AND FABRICATE ACCORDING TO SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE," FIGURE CORAM, INC. 1. DIRECT-EXPANSION COOLING WITH DEHUMIDIFICATION CAPABILITY 1-4, "TRANSVERSE (GIRTH) JOINTS," FOR STATIC-PRESSURE CLASS, APPLICABLE SEALING REQUIREMENTS, MATERIALS INVOLVED, DUCT-SUPPORT INTERVALS, AND 7358 S W DURHAM RD. 2. HOT-GAS BYPASS OTHER PROVISIONS IN SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE." PORTLAND, OR 97224 3. ELECTRIC REHEAT e. LONGITUDINAL SEAMS: SELECT SEAM TYPES AND FABRICATE ACCORDING TO SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE," FIGURE TYPE PNS 4. GAS HEAT 1-5, "LONGITUDINAL SEAMS - RECTANGULAR DUCTS," FOR STATIC-PRESSURE CLASS, APPLICABLE SEALING REQUIREMENTS, MATERIALS INVOLVED, DUCT-SUPPORT 5. INTEGRAL, DISCHARGE AIR TEMPERATURE AND HUMIDITY CONTROLS. INTERVALS, AND OTHER PROVISIONS IN SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE." DEALTYPE WR 6. ROOF CURBS. f. ELBOWS, TRANSITIONS, OFFSETS, BRANCH CONNECTIONS, AND OTHER DUCT CONSTRUCTION: SELECT TYPES AND FABRICATE ACCORDING TO SMACNA'S "HVAC DUCT 7. RELIEF FANS CONSTRUCTION STANDARDS - METAL AND FLEXIBLE," CHAPTER 2, "FITTINGS AND OTHER CONSTRUCTION," FOR STATIC-PRESSURE CLASS, APPLICABLE SEALING CS PROJECT NUMBER 0106369 1.3 DELIVERY, STORAGE, AND HANDLING REQUIREMENTS, MATERIALS INVOLVED, DUCT-SUPPORT INTERVALS, AND OTHER PROVISIONS IN SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND A. UNIT SHALL BE SHIPPED WITH DOORS SCREWED SHUT AND OUTSIDE AIR HOOD CLOSED TO PREVENT DAMAGE DURING TRANSPORT AND THEREAFTER WHILE FLEXIBLE." IN STORAGE AWAITING INSTALLATION. B. SEALANT AND GASKETS ARCHITECT OF RECORD B. FOLLOW INSTALLATION, OPERATION, AND MAINTENANCE MANUAL INSTRUCTIONS FOR RIGGING, MOVING, AND UNLOADING THE UNIT AT ITS FINAL LOCATION. a. GENERAL SEALANT AND GASKET REQUIREMENTS: SURFACE-BURNING CHARACTERISTICS FOR SEALANTS AND GASKETS SHALL BE A MAXIMUM FLAME-SPREAD INDEX C. UNIT SHALL BE STORED IN A CLEAN, DRY PLACE PROTECTED FROM CONSTRUCTION TRAFFIC IN ACCORDANCE WITH THE INSTALLATION, OPERATION, AND OF 25 AND A MAXIMUM SMOKE-DEVELOPED INDEX OF 50 WHEN TESTED ACCORDING TO UL 723; CERTIFIED BY AN NRTL. MAINTENANCE MANUAL. 1) TWO-PART TAPE SEALING SYSTEM 2) TAPE: WOVEN COTTON FIBER IMPREGNATED WITH MINERAL GYPSUM AND MODIFIED ACRYLIC/SILICONE ACTIVATOR TO REACT EXOTHERMICALLY WITH TAPE TO PART 2 - NOT APPLICABLE FORM HARD, DURABLE, AIRTIGHT SEAL. 3) TAPE WIDTH: 3 INCHES. PART 3 - EXECUTION 4) SEALANT: MODIFIED STYRENE ACRYLIC. 3.1 FIELD QUALITY CONTROL 5) WATER RESISTANT. A. MANUFACTURER'S FIELD SERVICE: A FACTORY-AUTHORIZED SERVICE REPRESENTATIVE SHALL INSPECT, TEST, AND ADJUST COMPONENTS, ASSEMBLIES, AND 6) MOLD AND MILDEW RESISTANT. EQUIPMENT INSTALLATIONS, INCLUDING CONNECTIONS. REPORT RESULTS IN WRITING FOR ENGINEER TO REVIEW. 7) MAXIMUM STATIC-PRESSURE CLASS: 2-INCH WG, POSITIVE AND NEGATIVE. B. TESTS AND INSPECTIONS (PRE-STARTUP): 8) SERVICE: INDOOR AND OUTDOOR. 1. AFTER INSTALLING RTUs AND AFTER ELECTRICAL CIRCUITRY HAS BEEN ENERGIZED, TEST UNITS FOR COMPLIANCE. 9) SERVICE TEMPERATURE: MINUS 40 TO PLUS 200 DEG F. 2. INSPECT FOR AND REMOVE SHIPPING BOLTS, BLOCKS, AND TIE-DOWN STRAPS. 10) SUBSTRATE: COMPATIBLE WITH GALVANIZED SHEET STEEL (BOTH PVC COATED AND BARE), STAINLESS STEEL, OR ALUMINUM. FOR INDOOR APPLICATIONS, USE 3. OPERATIONAL TEST: AFTER ELECTRICAL CIRCUITRY HAS BEEN ENERGIZED, START UNITS TO CONFIRM PROPER MOTOR ROTATION AND UNIT OPERATION. SEALANT THAT HAS A VOC CONTENT OF 250 G/L OR LESS WHEN CALCULATED ACCORDING TO 40 CFR 59, SUBPART D (EPA METHOD 24). 4. TEST AND ADJUST CONTROLS AND SAFETIES. REPLACE DAMAGED AND MALFUNCTIONING CONTROLS AND EQUIPMENT. 2. DUCT ACCESSORIES CONSULTANT: D. REMOVE AND REPLACE MALFUNCTIONING UNITS AND RETEST AS SPECIFIED ABOVE. 3.2 STARTUP SERVICE A. VOLUME DAMPERS A. FACTORY-AUTHORIZED SERVICE REPRESENTATIVE TO PERFORM STARTUP SERVICE; FURNISHED BY OWNER. a. LOW-LEAKAGE RATING AND BEARING AMCA'S CERTIFIED RATINGS SEAL FOR BOTH AIR PERFORMANCE AND AIR LEAKAGE. , B. UNIT MANUFACTURER TO COMPLETE INSTALLATION AND STARTUP CHECKS WITH ASSISTANCE AND COOPERATION OF THE INSTALLING CONTRACTOR. CHECKLIST , , .. TO INCLUDE BUT NOT LIMITED TO THE FOLLOWING: b. FRAMES: 1. INSPECT FOR VISIBLE DAMAGE TO UNIT CASING. - HAT SHAPED M - GALVANIZED-STEEL CHANNELS, 0.064 INCH THICK. 2. INSPECT FOR VISIBLE DAMAGE TO COMPRESSOR, COILS, AND FANS. - MITERED AND WELDED CORNERS. Stantec 3. VERIFY THAT LABELS ARE CLEARLY VISIBLE. c. BLADES: 4. VERIFY THAT CLEARANCES HAVE BEEN PROVIDED FOR SERVICING. 111 GRANT AVENUE SUITE 201 - MULTIPLE BLADE WITH MAXIMUM BLADE WIDTH OF 8 INCHES. 5. REMOVE ALL SHIPPING WOOD FROM THE BLOWER SECTION(S). - OPPOSED-BLADE DESIGN FOR RECTANGULAR DUCT, SINGLE BLADE FOR ROUND DUCT. ENDICOTT, NY 13760 6. ON DOWN DISCHARGE HEATING UNITS, MAKE SURE ALL SHIPPING WOOD SUPPORTS ARE REMOVED FROM HEAT EXCHANGE (SIDEWALL ACCESS). - GALVANIZED STEEL. 0.064 INCH THICK. Tel. (607)-321-6100 7. REMOVE ALL OTHER SHIPPING WOOD, SHIPPING BOLTS AND BLOCKS FROM ISOLATED BLOWER ASSEMBLIES, HEAT WHEEL, HEAT PIPES, AND CONDENSER - BLADE EDGING: CLOSED-CELL NEOPRENE EDGING. SECTIONS. REMOVE ALL SHIPPED LOOSE ITEMS AND SPARE FILTERS FROM UNIT SECTIONS. www.stantec.com PROJECT#191001405 8. REMOVE SHIPPING CLIPS/MATERIAL FROM COMPRESSOR ASSEMBLIES. 3. DUCT INSULATION SHALL BE KNAUF DUCT WRAP ON ALL DUCTWORK WITH VAPOR BARRIER, MIN. R-6 9. CONFIRM FOR ALL UNITS SHIPPED SPLIT THAT THE SECTIONS ARE JOINED, THE WIRING IS COMPLETED AND AIR FILTERS ARE INSTALLED. 4. CONDENSATE DRAIN PIPING SHALL BE TYPE "M" HARD DRAWN COPPER TUBING WITH WROUGHT COPPER FITTINGS AND LONG RADIUS ELBOWS. SIZES SHALL BE 3/4" UNLESS 10. CONFIRM REFRIGERATION LINES ARE CONNECTED AND SYSTEM IS CHARGED. INDICATED OTHERWISE ON THE DRAWINGS; RUN TO ROOF OR DRAINS AS NOTED. DEVELOPER: 11. CONFIRM GAS CONNECTIONS ARE COMPLETED; LINES PURGED AND PROPER INLET GAS PRESSURE IS AVAILABLE IF APPLICABLE. 5. EQUIPMENT FLEX CONNECTION SHALL BE DURO DYNE EXCELON OR APPROVED EQUAL. 12. CONFIRM VENT LINES ARE CONNECTED AND INSTALLED PER ENGINEERED AIR'S INSTALLATION AND MAINTENANCE MANUAL. 6. ELECTRIC DUCT HEATERS (REHEAT COILS) GENERAL: 13. CONFIRM ALL REMOTE WIRING IS COMPLETED TO UNIT INCLUDING REMOTE STATUS PANELS IF PROVIDED AND CONTROLS (BY OTHERS). A. DUCT HEATERS SHALL BE INDEECO, TYPE QUZ STANDARD FLANGED HEATERS 14. CONFIRM MAIN POWER IS TURNED ON TO THE UNIT DISCONNECT SWITCH. LEAVE DISCONNECT "ON" FOR COMPRESSOR CRANKCASE HEATERS B. APPROVALS: HEATERS AND PANELBOARDS SHALL MEET THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE AND SHALL BE LISTED BY UNDERWRITERS 15. CONFIRM CORRECT VOLTAGE, FUSE SIZE, BREAKER SIZE AND WIRE SIZE HAVE BEEN CONNECTED. LABORATORIES FOR ZERO CLEARANCE TO COMBUSTIBLE SURFACES AND FOR USE WITH HEAT PUMPS AND AIR CONDITIONING EQUIPMENT. 16. CONFIRM DUCTWORK IS COMPLETED TO UNIT. C. HEATING ELEMENTS SHALL BE OPEN COIL, 80% NICKEL, 20% CHROMIUM, GRADE A RESISTANCE WIRE. TYPE C ALLOYS CONTAINING IRON OR OTHER ALLOYS ARE NOT 17. CONFIRM ALL CONSTRUCTION WORK IN UNIT OPERATING AREA IS COMPLETED. ACCEPTABLE. COILS SHALL BE MACHINE CRIMPED INTO STAINLESS STEEL TERMINALS EXTENDING AT LEAST 1-INCH INTO THE AIRSTREAM AND ALL TERMINAL HARDWARE 18. INSPECT FAN-WHEEL ROTATION FOR MOVEMENT IN CORRECT DIRECTION WITHOUT VIBRATION AND BINDING. SHALL BE STAINLESS STEEL. COILS SHALL BE SUPPORTED BY CERAMIC BUSHINGS STAKED INTO SUPPORTING BRACKETS. 19. REVIEW INSTALLATION, OPERATION AND MAINTENANCE MANUALS FOR ANY OTHER ITEMS THAT REQUIRE ATTENTION. D. HEATER FRAMES AND TERMINAL BOXES SHALL BE CORROSION RESISTANT STEEL. UNLESS OTHERWISE INDICATED, THE TERMINAL BOX SHALL BE NEMA 1 CONSTRUCTION 20. COORDINATE AVAILABILITY OF RELATED TRADES FOR SCHEDULED START UP DATE (GAS FITTER, REFRIGERATION MECHANIC AND ELECTRICIAN). AND SHALL BE PROVIDED WITH A HINGED, LATCHING COVER AND MULTIPLE CONCENTRIC KNOCKOUTS FOR FIELD WIRING. 21. CONFIRM THERE ARE NO AIR FLOW RESTRICTIONS. ENGINEERED AIR IS NOT RESPONSIBLE FOR DAMAGES TO EXTERNAL DUCT WORK DIFFUSERS OR E. ALL HEATERS SHALL BE FURNISHED WITH A DISC TYPE, AUTOMATIC RESET THERMAL CUTOUT FOR PRIMARY OVER-TEMPERATURE PROTECTION. ALL HEATERS SHALL ALSO MIXING BOXES. BE FURNISHED WITH DISC TYPE, LOAD CARRYING MANUAL RESET THERMAL CUTOUTS, FACTORY WIRED IN SERIES WITH HEATER STAGES FOR SECONDARY PROTECTION. 22. SITE IS SAFE TO WORK ON AND MEETS MINIMUM REQUIREMENTS FOR GOVERNING SAFETY CODE AND APPLICABLE LAWS. HEAT LIMITERS OR OTHER FUSIBLE OVER-TEMPERATURE DEVICES ARE NOT ACCEPTABLE. SEAL: top PRopt 23. CONFIRM THAT THE DRAIN CONNECTIONS FROM THE UNITS ARE ALL COMPLETED (SEE OPERATIONS AND MAINTENANCE MANUALS FOR INSTRUCTIONS) F. HEATERS SHALL BE RATED FOR THE VOLTAGE, PHASE, AND NUMBER OF HEATING STAGES INDICATED IN THE SCHEDULE. ALL THREE-PHASE HEATERS SHALL HAVE %N 24. ENSURE THAT ALL HEAT EXCHANGER CONDENSATE LINES FOR THE HIGH EFFICIENT INDIRECT FIRED (INDOOR AND OUTDOOR UNITS) ARE ALL EQUAL, BALANCED, THREE-PHASE STAGES. ALL INTERNAL WIRING SHALL BE STRANDED COPPER WITH 105'C INSULATION AND SHALL BE TERMINATED IN CRIMPED # G . le �, COMPLETED. CONNECTORS OR BOX LUGS. a i-' 25. CLEAN CONDENSER COIL AND INSPECT FOR CONSTRUCTION DEBRIS. G. TERMINAL BLOCKS SHALL BE PROVIDED FOR ALL FIELD WIRING AND SHALL BE SIZED FOR INSTALLATION OF 75C COPPER WIRE RATED IN ACCORDANCE WITH NECV . - 26. INSPECT AND RECORD PERFORMANCE OF INTERLOCKS AND PROTECTIVE DEVICES; VERIFY SEQUENCES. REQUIREMENTS. 7., ,, 601 :401 INSPECT CONTROLS FOR CORRECT SEQUENCING OF HEATING, MIXING DAMPERS, REFRIGERATION, AND NORMAL AND EMERGENCY SHUTDOWN. H. HEATERS SHALL BE FURNISHED, EITHER WITH THE CONTROL OPTION SPECIFIED IN THE SCHEDULE AND DESCRIBED BELOW, OR WITH THE SPECIFIC COMPONENTS LISTED �1;>: t 28. MEASURE AND RECORD THE FOLLOWING MINIMUM AND MAXIMUM AIRFLOWS. PLOT FAN VOLUMES ON FAN CURVE. IN THE SCHEDULE. 44?ERT J.GC3 a. SUPPLY-AIR VOLUME. 1) OPTION K - THERMAL CUTOUTS, AIRFLOW SWITCH, CONTACTORS (WHERE REQUIRED), SCR (WITH STEP CONTROLLER IF HEATER DRAWS OVER 96 AMPS b. RETURN-AIR VOLUME. THREE-PHASE HEADER 192 AMPS CT SWITCH.LE-PHASE), FUSES (IF OVER 48 AMPS), CONTROL CIRCUIT TRANSFORMER, AND BUILT-IN SNAP-ACTING DOOR EXPIRATION - f `s c. RELIEF-AIR VOLUME. I. WHEN SPECIFIED IN THE SCHEDULE, OR BELOW, HEATERS WILL BE SUPPLIED WITH THE FOLLOWING SPECIAL FEATURES: d. OUTDOOR-AIR INTAKE VOLUME. 1) INSULATED TERMINAL BOX 29. SIMULATE MAXIMUM COOLING DEMAND AND INSPECT THE FOLLOWING: 2) TRANSFORMER SECONDARY FUSING (CLASS II) a. COMPRESSOR REFRIGERANT SUCTION AND HOT-GAS PRESSURES. 3) STEP CONTROLLER REVISIONS: J. WHEN SPECIFIED IN THE SCHEDULE, OR BELOW, HEATERS SHALL BE SUPPLIED WITH THE FOLLOWING THERMOSTATS: b. SHORT CIRCUITING OF AIR THROUGH CONDENSER COIL OR FROM CONDENSER FANS TO OUTDOOR-AIR INTAKE. 1) PROPORTIONAL ELECTRONIC ROOM THERMOSTAT A ISSUE FOR BID/PERMIT 06/06/2017 30. VERIFY OPERATION OF REMOTE PANEL INCLUDING PILOT-LIGHT OPERATION AND FAILURE MODES. INSPECT THE FOLLOWING: a. LOW-TEMPERATURE SAFETY OPERATION. 7. HUMIDITY SENSOR b. FILTER HIGH-PRESSURE DIFFERENTIAL ALARM. A. VAISALA HMW93D WALL-MOUNTED HUMIDITY SENSOR c. RELIEF-AIR FAN OPERATION. B. POWER PROVIDED FROM ENGINEERED AIR UNIT POWER SUPPLY; COORDINATE WITH UNIT MANUFACTURER. d. SMOKE AND FIRESTAT ALARMS. C. ACCURACY: +/- 1.7% RH AT 50" TO 104"F FROM 0 TO 90% RH D. SIGNAL OUTPUT: 0 TO 10 VDC 3.3 CLEANING AND ADJUSTING E. SUPPLY VOLTAGE: 18 TO 35 VDC; 24 VAC A. OCCUPANCY ADJUSTMENTS: WHEN REQUESTED WITHIN 12 MONTHS OF DATE OF SUBSTANTIAL COMPLETION, PROVIDE ON-SITE ASSISTANCE IN ADJUSTING F. NIST CALIBRATION CERTIFICATE SYSTEM TO SUIT ACTUAL OCCUPIED CONDITIONS. PROVIDE UP TO TWO VISITS TO SITE DURING OTHER-THAN-NORMAL OCCUPANCY HOURS FOR THIS PURPOSE. B. AFTER COMPLETING SYSTEM INSTALLATION AND TESTING, ADJUSTING, AND BALANCING RTU AND AIR-DISTRIBUTION SYSTEMS, CLEAN FILTER HOUSINGS AND 8. SUBMITTALS: PROVIDE SUBMITTALS FOR REVIEW AND APPROVAL FOR ALL CRITICAL MATERIAL AND EQUIPMENT, TO INCLUDE BUT NOT BE LIMITED TO; INSTALL NEW FILTERS. a. REHEAT COILS 3.4 DEMONSTRATION b. VOLUME DAMPERS, GRILLES. c. ELECTRICAL EQUIPMENT. 3 A. ENGAGE A FACTORY-AUTHORIZED SERVICE REPRESENTATIVE TO TRAIN OWNER'S MAINTENANCE PERSONNEL TO ADJUST, OPERATE, AND MAINTAIN RTUs. d. HUMIDISTAT. o e. DUCT FABRICATION/INSTALLATION DRAWINGS DRAWING BY: r 7 a 9. PROVIDE RECORD DOCUMENTATION OF FINAL TESTING, BALANCE, AND COMMISSIONING TO OWNER AND ENGINEER. DATE: JUNE 06, 2017 c 3 E JOB NUMBER: 2016285.50 2 in TITLE: PORTLAND "RENOVATIONS" MECHANICAL - s 5 SPECIFICATIONS (:). - g SHEET NUMBER: E M- 1 .O g NC�MIurEt�fS..•. ...,,.', �.,,,...,.�.,.,•�.... A . k._ 0 • 4 -'' � DEMOLITION KEYED NOTES � TIIPCVS 1 NOT USED I I o 16------- O REMOVE ALL DUCTWORK AS INDICATED.p r,, II „ , + I ,,,:aCD REMOVE EXISTING TRANSFER GRILLE. PREP S60 O4 REMOVE ALL 0 EXISTING FFUs. ..A111L4 o its p ROOM CO +► COMpOUNDiN O REMOVE IXISTING RETURN GRILLE. # 102 — ' �— - I14� Ar ROO'NSTORE NUMBER AN N II .Li 101 CORAM, INC. C.�I I _ 7358 S W DURHAM RD. r IIITI 2 I - ! ; I PORTLAND, OR 97224 I 7\120N, Oi __ _ • 120 , 10� PRO CTT PH .'Y C ��' � ''- -� - � I ”' INSTALLATION KEYED NOTES 17 I—I F ri 0 )01,6, 77 ® �� 1-:I All I ~'1-610 — — OE+ —� _I_ O 22"x14" SA DOWN FROM RTU-1. W 0106369 , INoselidillA , 1 ,,, 1- - 12 i 1 e�'�►V IV_ l'i: p 22"x12" RA UP TO RTU OF R I . � � ECORDp ARCHITECT 2 'T --. E I Q 0 12"x6" RA UP FROM LOW WALL RETURN GRILLE. IV TO I ItP t I I i- - I - -Y. j ' — _ — a. { E 4ti� 0 24"x8" TRANSITIONED TO 12"x8" RECIRCULATION AIR UP FROM LOW WALL RETURN \ I I , 0 I s ) OMPONDINc1GRILLE. \ \ III RaaM I � © ` 1 I ` I I' 14"x12" RA UP FROM 24"x8" LOW WALL RETURN DUCT. \ ! 1 , 1 '' y ' -'. . -CD , I CIRC. t 7j li *►a NI Ot• O18"x8" RA UP FROM 24"x8" LOW WALL RETURN DUCT. SECURE +�TQRAGE �2� . I COOLERI _ A �' .��' ` 4i �104' EMI 126 �j1��s \� - 4— , — O 32"x8" RECIRCULATION AIR UP FROM 63"x8" LOW WALL RETURN DUCT. ��� !' _ I 0 NEW 2X4 FFU. REFER TO SPECIFICATION AND SCHEDULE. BALANCE TO CFM SHOWN. CONSULTANT: ` I I I 17• •► .► �► `:. '.r`:. •.i p PROVIDE 0-10 VDC NIST TRACEABLE HUMIDISTAT. WIRE TO RTU HUMIDITY INPUT. 4Stantec—� —� -- —� -- REFER TO M-1.0 FOR HllMIDISTAT SPECIFICATIONS.- illillp \\000," ,rAmir =... „...„ i„.00,, � II � 24 x15 SA DOWN FROM RTU-2. 11O OPROVIDE AND MOUNT BUBBLE TIGHT DAMPER IN EXHAUST DUCTWORK AS SHOWN. REFER I / .` II I IITO M-2.1 FOR SCHEDULE. Stant@C \ / -1 J r --�' K.‘_ K,,s.,_...ir..I II 111 GRANT AVENUE SUITE 201 I .1 ENDICOTT, NY 13760 D — — i TeL_ _ _. . .. - 607)-31-6100 41 1 I www.stantec.com PROJECT#191001405 1111011r A MECHANICAL DEMOLITION PARTIAL FIRST FLOOR PLAN N �L M-1.1 SCALE:1/4 =1 0 II k 0 , 4 T 280 CFM RHC O RG-1 O RG-2 © 0 —106 RG—1 (2X)FFU-1 i-_-- i__�= 1111111511111 r /r PIMA VD 290 CFM ' Nr. RHC-106 �.-_ FFU 1 .-,---... AM 250 'CFM 11:16:,K,, _ O (3X) x\ jo+8 ��.,r �+w. 20x 12 U-1 tkV1411 M� SEAL: ���Ep ROpten � 16x8 - 14x8 �� G 3 N F '"�b �I_ " 0 # , 392 CFM 392 CFM ilWAI, I,� 710 CFM ` 4,o g O' 8 ;- IIPAINI 1 , _ 1 I 6 •-• .P i� %/ a-EGQt�! r;��, 300 CFM • �• lir_ I N, (3X)FFU-1 ''',' Ir. // '/ / ' . ,I 12x6 ti. 405 CFM �, I 1 / 1 22x16- Ihmi RG-1 I �b` 4252 CFM _ 0 n v _ °ERT.I.G Ammh. 2 " ` , _ \ ,� 18"x 14" 101lil 22x14 BAKER EDGEGAI�''? 4EXPIRAT10N DATE:4- �410 - _ ____. .�►,. LO "TU 2 .♦ 14. �1u41X1=D AIR PLEN 4 Mii6h:HC __. ..__Tm._._ -._ :�� 1D 1r ,I_' 0 16 10 g r - �, - O — O VE MEW V R 0 101 . FUrt € 'U-1 + 20x6ML— ■ RHC—100 380 CFM 380 CFM REVISIONS. E. `O/, FFU-1 ‘41\ /32.÷ +2 � ' _ �„` . ._ _;....._ ._., INV � II QISSUE FOR BiD/PERMIT Ofi/OB/2017 ♦ � •, � 22Eyi ' FFU-1 ,_6s ,/ 14x8 392 CFM 1�/I.I �" / / I:li„-- �O� kfropitib - RHC-10 g � � TT8Xrt4�" .moi. E V a �� � 0 Al 0 �— ,„ �► ISM►aI% 1 �:�, ' �.`pi ' RHC FFU-1 Mm 20x14 41110 POUI�DIN _ •,, —102 . ' 392 CFM .� 20x14 I I { RHC-102_.... .!_ 20xfi ' 1111 ZIE NA — ! I I �/ (Li (5 LU \iiUP THRU I FFU-1 O : Q ROOF TOEGU'E ! 392 CFM I I �1 ' O ' Q FsTORA..E IIIIIILlih- -g - _ � � � rAw 1134 G:- i1BULE I/ jFFU-1 FFU-1 DRAWING BY: T1 I (103) ,' — -- 80 — —380 FM1I BAKER EDGEGARD H BAKER EDGEGARD HF L DATE: JUNE 06, 2017 c . RG-1I i -_ L.._ ... _ II I ----- ' 1 JOB NUMBER: 2016285.50 I /7 41,,i TITLE. PORTLAND "RENOVATIONS" IIIIr ' imili z! FFU SPEED 1 I MECHANICAL DEMO/INSTALL sI CONTROLLER I I PARTIAL FIRST FLOOR PLANS .e, SHEET NUMBER: ill __________I 41102r (---- ii ,, _ , C•M E`N fS�������,� A II IIN .(ThMECHANICAL INSTALLATION PARTIAL FIRST FLOOR PLAN � M-1.1 SCALE:1/4 =1 -o N /� I I li / I (1) —_ \ ) C.-3) - n C4-) 7 2V c ...... ,CVS DEMOLITION KEYED NOTES < I 1_, — ......" 01 REMOVE EXISTMAININGTAIN ROOF CURBELECTRICALFE, RTU,ED DUCTFOR RISERS ANDCONNECTION< I 1_, — ,../ Health. \ NEW.OLS. 1-1 E I I I LI STORE Mme# �-� I D1 CORAM, INC. �y IN 1 - - - - - - 7358 S W DURHAM RD. I \ _� — I PORTAND, OR 97224 0 _ _ _ )3\___ — — — — L._, i — - - PO Cr TYPE PHARMACY tY DEAL PS FR \ CS PROJECT NUMBER 0106369 I I I • ARCHITECT OF RECORD \1 \ - - - - r � , ,, ! � � a I I [7 I I (ZiI 1 I II S I I 1 I 1 II CONSULTANT. EXIST - - - - - - - - Stantec RTU I OUTLINE OF CLEAN ROOM SPACES I BELOW FOR REFERENCE Stantec 111 GRANT AVENUE SUITE 201 ENDICOTT, NY 13760 D - .- - - - - T— Tel. (607)-321-6100 E I I WWW.stantec.com PROJECT#191001405 ri-- MECHANICAL DEMOLITION PARTIAL ROOF PLAN M-1.2 SCALE:1/4"=1'-0" N 1. i - ID 1--- (2) 1 ICI v\- (----4) ,_____ INSTALLATION KEYED NOTES 1 - -I - - - - - - - - — _1_ - - I OINSTALL NEW OWNER SUPPLIED RT UsAND ROOF CURBS. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION REGARDING INSTALLATION. /. © PROVIDE INSTALLATION OF EXHAUST FAN EF-1 AND ROOF CURB. SEAL: ,tD PROp I I COORDINATE WITH BUILDING OWNER TO MAINTAIN ROOF WARRANTY. REFER TO / K I I I I ARCHITECTURAL AND STUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION dirp ' ' N 4'"P _ REGARDING INSTALLATION. 4 w . 196P " / / \ CP _I ] �. f' OREGON / ✓ I I " I o 169 fl O - -- -- - - - - e TJ.- LAj RTU-2 _ omib L__ 4111111 —Le — — ��t 1........ _ I^ i�'1 i EXPIRATION DATE:‘-.Z..)--/1 v.z. i i \ I <4\s\ / / / \ 0 I RTU-1 • I I REVISIONS: A ISSUE FOR BID/PERMIT 06/06/2017 \ __ \ \ / \ �)i" I • I I \/ • l''.;': !'•;:- E -1 © :;i/ '.. .. 7/ 4. I (mt - I I I I 1 1 I DRA i I I I II WING BY: i DATE: JUNE 06, 2017 u. -1 _J JOB NUMBER: 2016285.50 CL — TITLE: PORTLAND "RENOVATIONS" EXIST - - - - - - - - " n 2 9 RTU I \— BELOW REFERENROOM SPACES I MECHANICAL DEMO/INSTALL Pi G PARTIAL ROOF PLANS " E 0 SHEET NUMBER: _§ - 1 V l- 1 . 2 - - - - - _. � � I I I 1 ` l MECHANICAL INSTALLATION PARTIAL ROOF PLAN II M-1.2 SCALE:1/4"=1'-0" c.w,`.�..UU�U�s�..1 V 6 d a RELIEF 1 200 AIR CFM RTU-2 RTU-1 KETED NOTE atrTF1 F F C ACCESS ACCESS ` I 'AGCESS i �, ACCESS ACCESS I ACCESS O SMOKE DETECTOR INSTALLED BY MECHANICAL CONTRACTOR. IP CVS otio, SECTION SECTION D Q L SECTION otioF SECTION SECTION p O L SECTION NS T EF-1 �S' O / T E 0A\ Fop *...___}'---) X E L HOOD `kip \` C°/ ELECTRIC l'_ ` R 770 % ELECTRIC X L E HOOD \ Health INLET HEATING S✓ Z *OA 910 CFM INLET HEATING Sr +OA 650 AIR COIL CFM AIR COIL CFM Lir L.L. U 1I� BTD-1 carn Ur„ ci 0 410-41 I- ' • U . - ---- RHC-106 CFM C FM C FM CFM C FM STORE KULEER • 3.1 kw r 600 Z T 600 off` T,7 875 — - 7 CORAM, INC. • 17 I II 7358 S W DURHAM RD. I CFM'CFM r ) CFM PORTLAND, OR 97224 • VD VD L� 900 2,010 ir 110 1 1,900 PROJECT TYPES �� • AHU-2 VDI— VDI^ CFM VDD` ililly 630 CFM . 280 CFM PLENUM I R H RHC-102 R H RHC-101 R H RHC-100 DEAL TYPE IM 55F 55FI ' r FM 10.0 kW V� 1.2 kW 21.1 kW A • (�) co (2) A CFM CFM iso I CS PROJECT 0106369 • ill Ala vii I 405 CFM 290 CFM 2,350 1,312 CFM EACH EACH I IHEPA/FFUI [HEPA/FFU[ NEW SA NEW SA NEW SA NEWT SA NEWT SA NEW'SA I NEVI SA NEW SA I I NEW SA NEW,SA NEWT SA NEWT SA NEWVSA ARCHITECT OF RECORD I01,215 CFM 0580 CFM 8FT IHEPA/FFUI IHEPA/FFUI JHEPA/FFUI IHEPA/FFUI IHEPAfFFUI IHEPAfFFUI SFT IHEPA/FFU IHEPA/FFUI I IHEPA/FFUI HEPA FFU HEPA FFU1-1577-(11HEPA FFU } CEILING `392 CFM c 392 CFM ' '392 CFM 392 CFM 0392 CFM 0392 CFM I CEILING 0250 CFM 0250 CFM I I 1 0380 CFM 0380 CFM 'i•380 CFM 0380 CFM 0380 CFM • i Yi i NEG. PRESSURE ROOM-105 ANTE ROOM-106 Ii i Yi i i I iv i 1 1 f I 1,263 CFM TOTAL 596 CFM TOTAL 109.5 SOFT 91.5 SOFT I TO RTU-1 70 ACH 40 ACH D TO RHC-102 1 1 TO RHC-101 I j TO RHC-100 I RG-1 VD I VENT TO VENT TO VENT TO VENT TO VENT TO 30 ACH I 51 ACH 390 CFM \ I I 42 ACH ROOM ROOM ROOM ROOM ROOM 1 RTU-2 RHC-106 I 507 SQ. FT. I 74 SQ. FT. 5J 415 SQ. FT4 API '4 - 'J RTU-2 BSC PREP ROOM-102 ANTE ROOM-101 I I CLEAN ROOM-100 BAKER BAKER BAKER BAKER j EXHA.: I HOOD - 1 EDGEGARD EDGEGARD EDGEGARD EDGEGARD a HOOD SG-404 VD RG-1 (2) RG-1 vD RG-2 VD I I VD RG-1 VF VF VF VFDE�IR RG-1 VD I 600 CFM 656 CFM 110 CFM i 875 CFM 00 875 CFM �T(2)RG-03 140 140 140 L 140 150 150 150 i1 150 150 J �� 150 425-2�_ ` 252 CFM CFM CFM CFM RG-03 "� CFM CFM CFM CFM ` CFM CFM t + CFM BSC } CONSULTANT': — EACH 300 CFM ; i 1 i t / 1 IAV, 1 FL JOFa) ' t AP TA AP TA - -- OP TA ,LP TA Sta ntec +0.03" WC (MIN.) +0.03" WC (MIN.)` +0.05" WC (MIN.) +0.05" WC (MIN.) Stantec LEGEND - 111 GRANT AVENUE SUITE 201 RTU- 1 & RTU-2 AIR FLOW SCHEMATIC M-2.0 SCALE:NONE SUPPLY AIR EA EXHAUST AIR ENDICOTT, NY 13760 ` --• — — RETURN AIR SA SUPPLY AIR Tel. (607) 321 6100 www.stantec.com PROJECT#191001405 TRANSFER AIR RA RETURN AIR – • • – EXHAUST AIR OA OUTSIDE AIR DEVELOPER: 1 f\/I OPPOSED BLADE DAMPER TA TRANSFER AIR ^J VOLUME DAMPER (VD) BTD BUBBLE TIGHT DAMPER t ELECTRIC DUCT REHEAT COIL J 1 I SHIPPING/ SECURE STORAGE-129 WAREHOUSE �0, ri `SST �P6iJF� • 130/131 �,,�? Q LM 9 150 150 SCP --`' CFM CFM 1 t /'� OREGON FLOOR - -- AI T .11 �°'noes,,. 0 FRT IGf`/' AP TA +0.05" WC (MIN.) RATION OA ` ::./aI r LP TA +0.05" WC (MIN.) REVISIONS: f ® ...2_,.,.._.....(4"-\ �y.. 0 0ISSUE FOR BID/PERMIT 06/06/2017 . I----',--r---, , , , , , � J ---r ( ,�W---- ' i, I - \-. , r: `. ; 0.05" — 0 ` 0� • I 0.05"lm. WC MIN. i` —# 0.03 WC MIN. 1 :_._. 1 AP- tieC; 11J = f '0 ' 0c / DIS: WC MIN. i 0.05" P-<4,,,'C' i WC MIN. 1 . / 1 i a:- is -- i 1 \r, NIF - ; �° . DRAWING BY: 1 i DATE: JUNE 06, 2017 " `°' �' I, ! GENERAL NOTE � `� f' 0.05" � � I , JOB NUMBER: 2016285.50 � � SWC MIN. CASCADEPRESSURI7ATION AIRFLOWS SHOWNARE TARGET VALUES FOR BALANCING. THE „�. TITLE: PORTLAND RENOVATIONS BALANCING CONTRACTOR SHALL ADJUST AIRFLOWS AS REQUIRED TO ACCOMPLISH g s / '�1 DIFFERENTIAL PRESSURES INDICATED IN PRESSURIZATION PLAN. II MECHANICAL AIR FLOW/DIAG. s / AND PRESSURIZATION PLAN o SHEET NUMBER: mg SIOa.g • llM-2 . O -1= axe (-2- MECHANICAL PARTIAL FIRST FLOOR – PRESSURIZATION PLAN 0 CIM E s: A u ii a M-2.0 SCALE:1/8"=1'-0" ROOF TOP UNIT SCHEDULE TAG AREA MANUFACTURER MODEL NUMBER DESIGN RETURN CONDENSER FAN OUTSIDE RELIEF SUPPLY FAN RELIEF FAN DX COOLING ELECTRIC REHEAT COIL FILTERS ELECTRICAL WEIGHT NOTES RTU HALF COUPLING NUMBER SERVED SUPPLY AIR AIR AMBIENT AIR AIR AIR ESP TSP MOTOR MOTOR COIL TC SC EAT EAT LAT LAT COIL VELOCITY TEMP. RISE (LB) DRAIN CONNECTION CLEANOUT PLUG IP CVS (CFM) (CFM) TEMP. (DEC. F) (CFM) (CFM) (IN WG) (IN WG) HP kW (MBH) (MBH) DB CO WB ('F) DB CO WB ('F) (FPM) kW FLA co PRE-FILTER FINAL FILTER VOLTS PHASE Hz MCA MOCP 111 RTU-1 COMPOUNDING SUITE ENGINEERED AIR FW102/K/O/MV/H/UVC 2,910 2,460 95 650 200 1.5 3.4 3.22 (2) 0 .19 1 106.6 91.1 71.3 57.5 44.9 44.3 409 11.0 13.8 10.8 2" MERV-8 4" MERV-13 : 460 3 60 46.0 50.0 3,400 1,2,3,4,5,6,7,9 RTU-2 NEG. PRESSURE RMS ENGINEERED AIR FW84/K/O/MV/UVC 910 0 95 910 0 2.5 4.2 1.44 N/A 1 57.2 39.2 91.8 72.4 _ 56.2 55.5 342 14 17.57 44 2" MERV-8 4" MERV-13 460 3 60 56.6 60 3,200 1,2,3,4,5,8,9 'IL NOTES: 2 28.8 13.2 56.2 55.7 44.2 44.2 467Health 1. UNIT INFORMATION PROVIDED FOR REFERENCE; UNITS PURCHASED BY OWNER. I -N r~ 2. COOLING COIL DATA IS BASED ON R-410A REFRIGERANT. 3. PROVIDE WITH 2" PLEATED - 30% EFF. PRE-FILTER SECTION AND 85% FINAL FILTER (PRIOR TO REHEAT). 4. PROVIDE REHEAT COIL FOR DEHUMIDIFICATION CYCLE. 5. PROVIDE ROOF CURB. TO ROOF 6. PROVIDE WITH RELIEF AIR FAN. (PN + 1 ") DRAIN 7. MAXIMUM SUPPLY AIR FLOW USED FOR RTU-1 SELECTION - 3,200 CFM. ( f STORE NUMBER 8. MAXIMUM SUPPLY AIR FLOW USED FOR RTU-2 SELECTION - 1,000 CFM. MIN. DROP • CORAM, INC. 9. SCHEDULED AIR FLOWS PROVIDED FOR UNIT SIZING. FOR BALANCING REFER TO DRAWING M-2.0 (PN /2) + 1 " 7358 S W DURHAM RD. MIN. LEG (PN = 8.14") C !:- 1,-/:-/) PORTLAND, OR 97224 PROJECT TYPES PHARMACY ELECTRIC REHEAT COIL SCHEDULE LOW WALL RETURN GRILLE SCHEDULE NOTES: DEAL TYPE h R TAG TYPE MANUFACTURER MODEL QUANTITY SIZE MATERIAL NOTES 1. EXTERNAL DRAIN PIPING, INCLUDING TRAP FOR CS PROJECT NUMBER 0106369 CONDENSATE TAG AREA SERVED BASIS OF DESIGN MODEL TOTAL EAT LAT DUCT SIZE VELOCITY (FPM) TOTAL ELECTRICAL NOTES NUMBER NUMBER W x H OF REQUIRED FOR ALL UNITS. NUMBER MANUFACTURER NUMBER CFM DB DB (W" x H") - kW (IN) CONSTRUCTION REDUCINGDIPSE SIZE AND NON-CONFORMANCE TO THESE DETAILS WILL HINDER CONDENSATE Q� CO ('F) MIN. DESIGN VOLTS PHASE Hz RG-1 LOW WALL RETURN GRILLE PRICE 630FF-SM-L-1-B12-HL 6 24"x24" ALUMINUM 1, 2, 3, 4, 5 REMOVAL FROM DRAIN PAN OF AH U. AIM IITECT OF RECORD 2. BASED ON BASIS OF DESIGN AH U. FINAL RHC-100 CLEAN ROOM INDEECO QUZ-K-U8 1,900 50 85 20" x 14" 320 977 21.1 r 460 3 60 1 RG-2 LOW WALL RETURN GRILLE - PRICE 630FF-SM-L-1--B12-HL 1 12"x24" ALUMINUM 1, 2, 3, 4, 5 DIMENSION TO BE DETERMINED DURING CONSTRUCTION. RHC-102 PREP ROOM INDEECO QUZ-K-U8 900 50 85 18" x 14" 340 514 10.0 460 3 60 1 RG-3 LOW WALL RECIRC GRILLE - NPR ANTE PRICE 63OFF-SM-L-1-B12-HL 3 16X16 ALUMINUM 1, 2, 3, 4, 5 RHC-101 ANTE ROOM INDEECO QUZ-K-Us _ 110 50 85 12" x 6" 210 220 1.2 460 3 60 _ 1 NOTES: (---8-. RTU DRAIN PAN PIPING DETAIL RHC-106 NPR ANTE ROOM INDEECO QUZ-K-U8 280 50 85 10" x 8" 250 504 3.1 460 3 60 1 M-2.1 SCALE: N.T.S. 1. PROVIDE WITH POWDER COATED FINISH IN BRIGHT WHITE. �� NOTES: 2. REFER TO PLANS FOR CFMs. 1 . PROVIDE WITH SCR CONTROL PACKAGE, DISCONNECTING CONTACTORS, AIR PRESSURE SWITCH, TRANSFORMER CLASS II, DOOR INTERLOCK 3. REFER TO DETAIL ON M-2.1 FOR FIT-UP. DISCONNECT SWITCH (NON-FUSED), 24V WALL THERMOSTAT, INSULATED CONTROL PANEL, HINGED LID, 4. PROVIDE WITH E MERV-8BLADEDAMPERPLEAED FILTER OPTION ( ) 5. PROVIDE OPPOSED BLADE SIMILAR TO PRICE VCS3AL. FAN FILTER UNIT SCHEDULE (POWERED TERMINAL) EXHAUST FAN SCHEDULE TAG LOCATION SERVICE MODEL DESIGN TOTAL FAN MOTOR ELECTRICAL NOTES TAG AREA MANUFACTURER MODEL QUANTITY MAXIMUM STATIC PRESSURE INLET ELECTRICAL NOTES NUMBER NUMBER CFM STATIC RPM HP NUMBER SERVED NUMBER CFM - INLET DOWN MIN. 1 TYPE/SIZE MOTOR MOTOR VOLTS PHASE Hz FLA (IN WG) VOLTAGE PHASE Hz CONSULTANT: (IN WG) (IN WG) (IN WG) TYPE WATTS EF-1 ROOF 4' BSC CUE-099-6-1/6 770 0.5" 1,336 1/6 115 1 60 1, 2 FFU-1 CLEANROOM SPACES ENVIRCO MAC 10 2x4 LEDC RSRE 18 850 1.0 0.5 0.2 DUCTED ECM 250 115 1 60 2.75 1, 2, 3, 4, 5, 6, 7 NOTES: CO NOTES: 1 . BASIS OF DESIGN MANUFACTURER: GREENHECK Sta � � 2. INCLUDE HORIZONTAL MOUNT EXHAUST DAMPER AND ROOF CURB. 1. UNIT FURNISHED BY OWNER AND INSTALLED BY THIS CONTRACT. 2. PROVIDE POWDER COAT WHITE PAINT FINISH FOR HOUSING AND SCREEN. 3. PROVIDE UNIVERSAL CONTROL CARD. Stantec 4. PROVIDE ROOM SIDE REPLACEABLE MOTOR ASSEMBLY, BAFFLE, AND 99.99% AT 0.3 MICRON FILTER, VANE RUNNER 5. ROOM SIDE 1/8" FNPT CHALLENGE PORTS: CONVENIENT AEROSOL CHALLENGE AND HEPA FILTER TESTING. 1 1 1 GRANT AVENUE SUITE 201 6. REMOTE SPEED CONTROLLER MOUNTED IN PREP ROOM. paw ENDICOTT, NY 13760 7. REMOVE PREFILTER PRIOR TO INSTALLATION. �� BUBBLE TIGHT DAMPER SCHEDULE Tel. (607)-321-6100 0 41"R TAG LOCATION SERVICE MODEL DESIGN TOTAL MOTOR ELECTRICAL NOTES WWW.StanteC.Com PROJECT#191001405 �� +� NUMBER NUMBER CFM STATIC HP HANGER RODS _ (IN WG) VOLTAGE PHASE Hz ROD POSITIONING NUT STEEL ANGLE BLADE STOP SOUR BANDS INSULATION2"R ABOVE SECURE �� BID-1 STORAGE 104 4' BSC "PSD" 770 0.5" 8.5 VA 115 1 60 1, 2DEVELOPER: HANDLE WITH SET SCREW BOLT TO DUCT VARIES ■■■■■■■■■ ■■■■■■■■■■e 900 NOTES: ALIGN HANDLE WITH1 1/8" SMALL DOUBLE VANE 1. BASIS OF DESIGN MANUFACTURER: RUSKIN - STANDARD CONSTRUCTION EXCEPT FOR DAMPER BLADE DUCT (TY ) GALVANIZED FRAMES, BLADES AND AXLES. 41111 III- 2. BELIMO SPRING TO BE TWO POSITION "FAIL CLOSED" ACTUATOR WITH INTEGRAL LIMIT BLADE POSITION LOCKNUT SWITCHES. MODEL AFBUP-S OR EQUAL. - -sl, 11 11 UI VANE RUNNER t1/4" CLEARANCE no ■■■■■■■■■■• ■■■■■■■■■■. In SAME GAUGE 12"MAX ALL-AROUND .L� ': E:� / AS DUCT ,..-- BEARING FITTING WI, , _..._ 77 BOLT TO DUCT BLIND RIVETS SUPPORT ANGLE �' m (OR WELD STUD) TYPE A TYPE B 2"R _ _ w SEAL: 4-3 ROTATION (90 DEG) -r--4111 �� _ SEAL: PROP i\l • ENSURE BOLTS CLEAR BLADE, DUCT WIDTH ROD DIAMETER TYPE SUPPORT ANGLE MAX. SPACING41 4 .. $ G1 N$ 4,'iY STAND-OFF BRACKET2„ OR INSTALL THEM IN OPPOSING " " " (0 4"R 4 b; • _PES j BOLT TO DUCT CORNERS AWAY FROM BLADE UP TO 24" USE 1x1/8 A NONE 4'-0" O.C. �� ROTATION \ '� 4 25" TO 36" 3/8" B 1 1/2"x1 1/2"x1/8" 8'-O" O.C. ' 1/4 90 �' �'" VARIES `� , I �P) tip. P' 3/8" DIA. THREADED ROD2 37" TO 48" 3/8" B 2"x2"x1/8" a'-a" o.c. LARGE DOUBLE VANE �RT3.G STEEL CLAMP, BOLT TO - ; 16 GA. STEEL BLADE BLADE, PROVIDE AN 49" TO 60" 3/8" B 2"x2"x3/16" 6'-0" O.C. r� �� ADDITIONAL ANTI-SLIP BOLT ' J 1 THRU THE ROD OTES: J 1. DAMPERS FOR ROUND DUCTS SHALL BE SIMILAR TO THE DAMPER SHOWN ABOVE. fii" TO 84" 3/8" B 2"x2"x1/46'-0" 0.0. rTh DUCT-TURN INSTALLATION DETAIL J 2. ENSURE THAT FULL 90' DAMPER BLADE MOVEMENT IS UNOBSTRUCTED. " " SELECT FOR 1/2" MAX. " M-2.1 SCALE: N.T.S. 3. FOR DUCT HEIGHTS MORE THAN 12", PROVIDE FACTORY-FABRICATED OPPOSED BLADE DAMPERS, ABOVE 84 3/8 B DEFLECTION AT DES. LD 6 -0 O.C. ",..._../ - 00 DUCT - CC CD REVISIONS: MAN UAL DAMPER '`- "_,,/ H A,ISSUE FOR BID/PERMIT 06/06/2017 rm (ADJUSTABLE SINGLE-BLADE BALANCING TYPE) 1-1/2"x5/16"x2"N0.16 : Allah. IMO. iMi, iAIM. rAM. AIM► — Alli . AIM, Allah. A111111 Ate. Alai. 4111111 riMIM.. AM. 41111111h. 411111r. AIM. 411111111 iMi, AIM. ` i0111111 . AIM. Ia► rA11111.h. Amu► Am. i111111b. A`. AIM. Am. Aim. Aim. r. .AM. Ailli A— .ii. Alibi. AM. Arai., A`► Alla. AM. Ani► iii, Ate. AIIIII► i 411111. _ AIM. .411111. AM► Ill\ AM. Ina. ii, rAIM. _ ri AIM. AIM\ AIM._ AIM. ir _ AIM. AIM. AIM. ii ` r PLUMBING LEGEND AND ABBREVIATIONS PLUMBING LEGEND AND ABBREVIATIONS CONT. GENERAL NOTES - DEMOLITION _ (APPLIES TO ALL DEMOLITION DRAWINGS) ' 1114 III UNION BFP-DC BACK FLOW PREVENTER, OF THE DOUBLE CHECK VALVE ASSEMBLY TYPE 1. DISCONNECT AND REMOVE EXISTING MATERIAL, EQUIPMENT, AND OTHER WORK AS NOTEDHe alt r PIPE ELBOW DOWN DHWRP DOMESTIC HOT WATER RECIRCULATION PUMP OR REQUIRED FOR PROPER INSTALLATION OF NEW SYSTEM(S). 0 PIPE ELBOW UP SWGP SEWAGE PUMP 2. REMOVAL OF CERTAIN EXISTING WORK WILL BE NECESSARY FOR THE SATISFACTORY ' PERFORMANCE OF THE GENERAL WORK. ALL EXISTING CONDITIONS ARE NOT COMPLETELY TEE OUTLET DOWN CMPR-LA COMPRESSOR - LAB AIR DETAILED ON THE DRAWINGS. CONTRACTOR SHALL SURVEY THE SITE AND MAKE ALL NECESSARY CHANGES REQUIRED BASED ON EXISTING CONDITIONS FOR PROPER �� ---0 TEE OUTLET UP ADR AIR DRYER INSTALLATION OF NEW WORK. STNEER CAPPED PIPE IDWH-S INSTANTANEOUS DOMESTIC WATER HEATER - STEAM 3. ALL NECESSARY CUTTING AND PATCHING ABOVE FINISHED FLOOR FOR THE PLUMBING CORAM, INC. FLOW ARROW WSFR WATER SOFTENER WORKSHALLBE PERFORMED BY THIS CONTRACTOR. RESTORE TO MATCH EXISTING 7358 S W DURHAM RD. IT PORTLAND, OR 97224 ECCENTRIC REDUCER VACP VACUUM PUMP 4. PLAN INSTALLATION OF NEW WORK AND CONNECTIONS TO EXISTING WORK TO ENSURE PRO‘ECTTYPE PHARIACY ®FD FLOOR DRAIN DSWU DISTILLED WATER UNIT MINIMUM INTERFERENCE WITH REGULAR OPERATION OF EXISTING FACILITIES. DEALTYPS PPR I CO. CLEAN OUT; WALL OR EXPOSED SK SINK 5. THIS CONTRATOR SHALL COORDINAE DEMOLITN WORK WTH OHER TRADE SE ESTABL SHINGCEXTENT OF REQU REDTREMO ALS IOTO COMPLY I WITHTCONSTRUCTION CTIONS IN a PROJECT NULEER 0106369 1 O CO. CLEAN OUT; FLOOR FH FUME HOOD DOCUMENTS AND SPECIFICATIONS. [IIM FLEXIBLE PIPE CONNECTION TMV TEMPERED MIXING VALVE 6. PERFORM DEMOLITION/ALTERATION WORK IN SUCH A MANNER AS TO MINIMIZE DAMAGE ARCHITECT OF RECORD I - (DCW) - DOMESTIC COLD WATER DN DOWN TO EXISTING WORK WHICH IS TO REMAIN. - (SDCW)- SOFTENED DOMESTIC COLD WATER 7. REPAIR OR REPLACE ANY APPURTENANCES THAT ARE TO REMAIN THAT WERE DAMAGED t DURING CONSTRUCTION. -- (DHW) - DOMESTIC HOT WATER NOTE: NOT ALL SYMBOLS AND ABBREVIATIONS INDICATED MAY 8. FOR THE SYSTEMS THAT ARE TO REMAIN, VERIFY SIZES IN FIELD FOR CONNECTION TO --- (DHWR)- HOT WATER RECIRC APPEAR ON THESE DRAWINGS NEW WORK. –-- --– (SAN,ST,AW) - UNDER SLAB PIPING 1 TW TEMPERED WATER } DW DISTILLED WATER / SAN SANITARY WASTE \... ` SV SANITARY VENT i `\ 1 ST STORM DRAIN GENERAL NOTES - INSTALLATION (APPLIES TO ALL INSTALLATION DRAWINGS) NG NATURAL GAS CONSULTANT: M AW ACID WASTE 1. FIELD COORDINATE THE LOCATIONS OF ALL PIPING WITH THE WORK OF OTHER TRADES AV ACID VENT AND THE BUILDING STRUCTURE. ---(NAME}— CHEMICAL SUPPLY PIPES 2. PROVIDE BALL VALVE ISOLATION VALVES AT ALL DROPS TO EQUIPMENT AND/OR '----- ---: an ec 1 CASEWORK. MATCH VALVE MATERIAL TO PIPING MATERIAL. HPS HIGH PRESSURE STEAM 3. ALL DOMESTIC COLD WATER (DCW) AND DOMESTIC HOT WATER (DHW) SUPPLY TO SINKS MPS MEDIUM PRESSURE STEAM SHALL BE 1/2" UNLESS NOTED OTHERWISE. PROVIDE FLEXIBLE FINAL CONNECTION TO Stantec -LPS LOW PRESSURE STEAM FAUCET. 111 GRANT AVENUE SUITE 201 HPC HIGH PRESSURE CONDENSATE 4. ALL BOP LABELS ARE APPROXIMATE AND SHALL BE COORDINATED WITH OTHER TRADES ENDICOTT, NY 13760 FOR EXACT LOCATIONS AND HEIGHTS. Tel. (607)-321-6100 MPC MEDIUM PRESSURE CONDENSATE LPC LOW PRESSURE CONDENSATE 5. ALL SANITARY PIPING 2 1/2" AND SMALLER SHALL PITCH 1/4"/FT. ALL SANITARY 4" www.stantec.com PROJECT#191001405 1 AND LARGER SHALL PITCH 1/8"/FT. ALL VENT PIPING SHALL PITCH 1/8"/FT. PC PUMPED CONDENSATE 6. ALL SINKS (LAB SINKS, SINKS, ECT.) DRAINS SHALL BE 1 1/2" UNLESS OTHER WISE VPD VACUUM PUMP DISCHARGE NOTED. DEVELOPER: -MU MAKEUP WATER AN ATMOSPHERIC VENT . 1 H HYDROGEN HE HELIUM - ( HPN HIGH PURITY NITROGEN --ZA ZERO AIR CD CONDENSATE DRAIN IX A GATE VALVE SEAL ` 70 BALL VALVE ,,okso PRop.,, --111---- BUTTERFLY VALVE 4,,6 fir` G j hi ' 1 F' . ----;v-- CHECK VALVE –4-4.--N-- BACK FLOW PREVENTER r/•- s Dki BALANCE VALVE --IVI-- PLUG VALVE T�.G 1�4 2-WAY CONTROL VALVE f EXPIRAT Qrl► ~"`� r %li ! I 3-WAY CONTROL VALVE I.I STRAINER REVISIONS: ( -----0 BACKFLOW PREVENTER S,ISSUE FOR BID/PERMIT 06/06/201 C04 PRV-1 PRESSURE REDUCING VALVE W/NUMBER ---I: VENTURI FLOWMETER ( 4 PRESSURE GAUGE W/GAUGE COCK 0 STEAM TRAP - LETTER DESIGNATES TYPE: FT - FLOAT AND THERMOSTATIC IS - INVERTED BUCKET TD - THERMODYNAMIC ( T TH - BAL. PRESSURE THERMOSTATIC T COLUMN THERMOMETER S � T WATER HAMMER ARRESTER DRAWING BY: MAV DATE: JUNE 06, 2017 ft MANUAL AIR VENT r AAgV JOB NUMBER: 2016285.50 AUTOMATIC AIR VENT TITLE: PORTLAND "RENOVATIONS" 49 RELIEF VALVE 28_( — 1{�I-- IN-LINE PUMP PLUMBING V N LEAD SHEET -� I-- PIPING FLANGE SHEET NUMBER: s= �o 0 POINT OF CONNECTION S CO POINT OF DISCONNECTION .EI o�,� P—O . 1 SE IA 4 r E 5( \•., ...1 o n COMMENTS: N a 1( 6 oli oV ..��.,N..-,/\.../"..�N......eN.-.,N.✓N.—.i'`..0' .. ✓N..-..oL..r\...,lN.. `,._.# ./N... `•-/ ..rte./`,_/' ..��./ ,✓ -oo ..fes/`✓ ..��....•s... ' .. .' .ems,✓` ✓ ..,N.✓`•✓ ..•W -." ....e .. ' ✓ .. `....,`s.,...•`�.., .-./N...,/`s-..r\,...eN.� ter" W 'ter W W '4111111► ''111.1r w •11.w 'IOW W W "11111110^' ter► '4111n.. W W 'MP" W 'IMP' A 1 ..--1..--1..--1 --1nom\/--.."--. — /1,---. rV �� �� I INSTALLATION KEYED NOTES GENERAL NOTES ` 2"VENT WITHIN CHASE 1-1/2" PUMPED O PROVIDE 2" VENT FROM SUMP PUMP & SINK TO WALL CHASE THRU ROOF AS NOTED. 1. COORDINATE INSTALLATION WITH OTHER TRADES. ,CVS : SAN. WITHIN CHASE 2. FIELD VERIFY EXISTING CONDITIONS BEFORE COMMENCING INSTALLATION. FRONT VIEW SCRUB SINK DETAIL 0 TIE INTO EXISTING DHW RUN OVERHEAD TO NEW SINK AS SHOWN. 3. PROVIDE INSULATION FOR PIPING PER ACCOMPANYING SPECIFICATIONS. 1-1/2" VENT / I © TIE INTO EXISTING DCW RUN OVERHEAD TO NEW SINK AS SHOWN. He aft h : r ' .., 4. CONTRACTOR SHALL COORDINATE ALL WALL AND ROOF PENETRATIONS. 1/2" DHW WITHIN CHASE EYEWASH (85'F) 0 RUN 2" SANITARY FROM NEW SINK IN CHASE TO PUMP AS SHOWN. PROVIDE SUMP 1/2 DCW SCRUB SINK, BRADLEY PUMP (SP-1) FOR NEW SINK SANITARY DRAINAGE. LITTLE GIANT MODEL #WRST-6 OR 5. EQUIPMENT, DUCTWORK AND PIPING TO RUN AT MAX. ELEVATION ABOVE CEILING. WITHIN CHASE (Y# YSINK-0294-OO), SUPPORT FROM JOIST ABOVE. .41 MODEL # 519-270HW EQUAL. FAUCET, #356128 (85T) ^'' �, �� 6. ALL PIPING TO BE COPPER. ` AND BASKET DRAIN `' STORE RIMIER RUN 1-1/2" PUMPED SANITARY DRAIN FROM SUMP PUMP SP-1 TO EXISTING DRAIN M #300287, RISER IN ANTE ROOM 111 AS SHOWN. PITCH PIPING TO EXISTING DRAIN/VENT AT CORAL INC. ` O c EAGLE GROUP 1/8"/FT. PROVIDE A 1 -1/2" CHECK VALVE & GATE VALVE (COPPER ALLOY) IN SUMP 735$ S W DURHAM RD. PUMP DISCHARGE RISER. PORTLAND, OR 97224 MIXING- FAUCET O O PROVIDE TOUCH-FREE SINK MANUFACTURED BY (EAGLE GROUP) MODEL# Y# PROJECT TPHARMACY VALVE AUTOMATOR r ' I YSINK-0294-00 WITH EMERGENCY EYEWASH (BRADLEY) MODEL# S19-270HW. DEALDEALThi ` ( EAGLE VALVE EAGLEI III #373848 #326696 0 PROVIDE ACCESS DOOR FOR INSTALLATION & MAINTENANCE OF SUMP PUMP. 1/2"-\.... ..,.. CS PROJECT NULEIEF 0106369 1/2"�- \ I , J DEMOLITION KEYED NOTES T l 77 A T OF RECORD 1 1 &PROVIDE REWORK OF EXISTING DCW, DHW, DRAIN VENT TO ACCOMMODATE NEW SINKS. - - 'f" - " I O T O REMOVE EXISTING COMPOUNDING ANTE ROOM SINK, WATER & DRAIN PIPING BACK TO ISOLATION ISOLALL (ACCESS\ j WITHIN WALL. CUT & CAP FOR USE WITH NEW NPR SINK TIE-INS FROM OUTSIDE OF VALVE 1-1/2" - l DOOR P-TRAP ` Q. ROOM. REFER TO NEW PIPING LAYOUT OVER PREP ROOM. 2 SAN. DRAIN 1 SP-1 l SUMP PUMP SCHEDULE 1 RUNNING IN PIPE CHASE i TAG SERVES AREA SERVED ITEM & MODEL TANK PSI PERFORMANCE ELECTRICAL NOTES NUMBER NUMBERS SIZE (GPM © HEIGHT IN FEET) NOTE: 1 5' 10' 15' 20' HP WATTS VOLTS PHASE Hz ` I 1. SCRUB SINK, FAUCET, AND EYEWASH ARE SUPPLIED AND INSTALLED BY SP-1 SCRUB SINK PREP & ANTE ROOMS 506065 WRSC-6 3 GALLON 7.8 46 29 13 N/A 1/6 720 115 . 1 60 1 GENERAL CONTRACTOR. - 2. DHW AND DCW SHALL BE FED FROM EXISTING SINK UNLESS OTHERWISE NOTES: NOTED. REFER TO PLAN, 7 GPM FLOW MINIMUM. -- 1 . REFER TO MANUFACTURER (LITTLE GIANT) SPECIFICATIONS FOR RECOMMENDED INSTALLATION. (TSCRUB SINK DETAIL CONSULTANT: ` P-1.0 SCALE: NTS GiStantec Stantec 111 GRANT AVENUE SUITE 201 ) ENDICOTT, NY 13760 Tel. {607)-321-6100 www.stantec.com PROJECT#191001405 1 4� DEVELOPER 0 ___,/,__ 24,-6„0 SP-1 1-1/2" f I i!SUMP PUMP (cKv)Tdr � 1/2" VENT I I 1 NPR ANTE - -- --.... _ _ i ROOM 2" VENT T� 3" - �— -.� —1 f�"; HW topTHRU ROOF � �•-� ��— �106� i 114 — — � C • EXISTING \ O/ ��a riii RISER: VENT 1/2" DCW ♦ © �`�\ I 1 DHW O PREP �/ /2" DCW ROOM ` . COMPOUNDING SEAL: 02) N . ANTE ROOM ,O „tDPROpe F \\ \� ,� ? 101 — — — ' GINE, \ ` ,, w 1 J __ i E ii1 � ...4.. 11 , / NEG. PRESSURE f \ � �-...A _ I14 ROOM ,�� ! GQ` \'\ 1051 f ,' [I i t I f I (EVIRATION DA - 1 \\T'''..„.........: / 1� \ f , N 1 l REVISIONS: N\,/, _i\ / ' ,L ISSUE FOR BID/PERMIT 06/06/201 \ I r---1 r 1 I . COMPOUNDING I ( I :I ROOM I 111 I I 1 I I 1 (100) - j mil SECURE STORAGE 3 104 VESTIBULE I (103) - - I I s I oi I I y ♦ � I � cl : i\-k I DRAWING BY: / — — — - - - ' DATE: JUNE 06, 2017 -1( ,' / I I / JOB NUMBER: 2016285.50 ( lI �..1 TITLE: PORTLAND "RENOVATIONS" E I 1 - �� PLUMBING INSTALLATION rlzs o , \` l All ---� I I PARTIAL FIRST FLOOR PLAN N . \ _�_ SHEET NUMBER: YT:- P- 1 .0 m1 PLUMBING PARTIAL FIRST FLOOR INSTALLATION PLAN ri COMMENTS: u n V- i �� SCALE: 1/4"=1'-0" N © iz — Niow• New. mow w � � � � � � -iiiw.. -.� � � � � � � � � NIIMIllw NNW"' 'Mr � � � � 'imp., w � � � Num. � � � ....prNow" Nigwr mum. Num. Num. ...... w ..... Nimpp. Niumppr mimpo. Num. Num. wNew Now, w � � � � � NEP, � � � -rwir- "mow NrirrNoir mow- NewNompvw � mom, Niarr Nomov Nimir w Nomr- w w w ������.. A 0 0 0 4 I '.) IP CVS ' 12 -1172= 7'- f, _10't GENERAL NOTES 1 E I ! : 1. SPRINKER CONTRACTOR SHALL PERFORM SPRINKLER i 1 ( ( SHUTDOWN, DRAIN DOWN OF SYSTEM, FIRE WATCH, AND I III SHALL COORDINATE WITH THE SITE SECURITY, MAINTENANCE, �, E AND HSE DEPARTMENT. Health it ` 2. PROVIDE TEMPORARY CAP/PLUG AT LOCATIONS WHERE PIPING ■. j- Illal � I / €� OR SPRINKLER HEADS HAVE BEEN REMOVED TO MAINTAIN R©©M I "� SYSTEM OPERATION DURING CONSTRUCTION. CO •OUND NG Ail (TYP.} 102 I ATI= Re•M • 3. REFER TO DRAWING M-000 FOR FIRE PROTECTION LEGEND, &from MEER SYMBOLS, ABBREVIATIONS, AND DETAILS. �101� L I 7358 CORAM, S WC DURHAM R . DU D PORTLAND, OR 97224 0 - - - - PROJECT pwpw�� CT�ypE PHARIACY 11\oole, 1441111111=06mmIL IN II , i DEAL TYPE: MIR i f f /1111111111111111 0t '! . 1i 11111111111111111111 ARCHTEC OF RECORD DEMOLITION KEYED NOTES TIIIIIIMIIIMMIIMII • 1,116111 I J. I l 1111111111111111111111 I 11 ,- La (I [ro REMOVE ALL EXISTING PENDENT SPRINKLER HEADS IN THE PREP ROOM, ANTE ROOM AND ! f - _m - ^ - - - I / (� ' COMPOUNDING ROOM AS SHOWN, TYPICAL FOR 14 HEADS. ti €WO,, li\,MEE ,......, ,,...,...:.. ;! !1 I _ / COMPOJNDIN / _E 1 \ I RC7CJM �' I \ III ij 1 1 I N I!I ! i ( g : .11 -.._ il ! III f oo !- CIRC I E I I !IJ i ( j SECU'•E \ i E2 ' I I i - !!! I .TQRA,.E i I COOLER , II I • • \ 104 1 111 41111111111 • filr 1.----- 1 --,_ , 4110 >.<._ .N. � - mimi - - - I CONSULTANT: .4i _ ....... . II , . P lgpr ,'- , ,, /, • , , . , _Th \ , , , - __ ___-. __ CO 1, - - -- ,; FIRE PROTECTION LEGEND Stantec ./: , il Sanec x , ...4 I I - ��� ` I ` I I 111 GRANT AVENUE SUITE 201 15 -0= S=-_0» 2u'-0� - • PENDENT SPRINKLER HEAD -- -. -- _ I _ _ — _ ENDICOTT, NY 13760 i SIP O CONCEALED PENDENT SPRINKLER HEAD Adr _�.L. Tel. (607)-321-6100 0 ` 1 wwwstantec.com PROJECT#191001405 / \\ 1 I I ;f ' 1 FIRE PROTECTION DEMOLITION PARTIAL FIRST FLOOR PLAN I NOTE: - FP-1.O SCALE:1/4"=1*-0" �� - HEAVY LINE INDICATES NEW PIPING DEVELOPER: N - LIGHT LINE INDICATES EXISTING PIPING f--; CO0 L4 1..-- 12I-11 ' __ _ __ ` I • - ANTE - E -- 1 ,_�� ' I rr fI-- I ijo 1 R O M mit® .........,.. amt "' :f /N 74*Illtiki. ... -- ,dirm_ ® 1 . (0 .L: _too PRopk:s,. ,,,,, PREP "' I � � 1S.- � ,:y-. 102 CQ "QUfv '� ,�I „ / FrA KIM ANTE RQ•M O /` OREOON ' idhi,\ A f \ 4I� 4I .I ' `' !�101 I 4\ 11.' �� �� I I A ■� INSTALLATION KEYED NOTES EXPIRATION DATEAMIM C ... o\Ars.....,�� - ;, ! 1 PROVIDE NEW CLEAN ROOM TYPE CONCEALED SPRINKLER HEADS IN NEW CEILING „� ! EVSYSTEM IN PREP ROOM, ANTE ROOM AND COMPOUNDING ROOM AS SHOWN, TYPICAL 7► O ,� I i ■ FOR 14 HEADS. HEADS TO BE RELIABLE G5 HEADS OR EQUIVALENT WITH K-FACTOR ��' 05 I MI TO MATCH EXISTING. II -v !'.--- MINI E = REVISIONS: 1 1 • , \I y „ • • v ? 1 WI I J A ISSUE FOR BID/PERMIT 06/06/2017 WI Ar i OP 1 ., , (7—\ iv/z Alt Alak I , . , / i t,,,,___ , / - wig -2nie f: k 1 i --;., . r- --ril friteSi ':.-iv ivy- ii _J... O f 11111 rill IIIIMill II'I i I ! , OMPO�JNDIN 1IIRIII1••1I1IIII1 i I ROOM t cV fl t /11111111 Illfl_,! I im,_...,1 = SUPPORT i i I `; PROVIDE IIIIIIIIII SECU" il mitpi, i I 1101 M i T©RAr- I �! I 0 pLv] .i kik: I i 1v^4 �_ V TIBLE�vf I 1- / I - BRANCH OR MAIN o ♦ E �C ; ;= DRAWING BY i 7 * • ' V -_— I ! I t i ;� DATE: JUNE 06, 2017 E E E .., - I I ' t l b. I I I 1 i f ' _�-- i— -- VIC FLEX NUMBER: 201 5.50 1 JOB NU 628 a ' - -�- f -- i ADJUSTABLE HUB (FLEXIBLE FITTING) �' i i/ , SPRINKLER DROP TITLE: "RENOVATIONS" I • I I . �� N„,,i t I 1" x , 2�-_� FIRE PROTECTION DEMO/INSTA . s = \I, ! '':� I REDUCRAi / SUSPENDED oR RIGID CEILING PARTIAL FIRST FLOOR PLANS N t 1 '-C 5 -O 20 -v ' ' fIlAWo _ _ SHEET NUMBER: cg — _ __. __ ,_ 165'F CONCEALED 1 g �-/ I 11111r W ---I ! WITH EAD �a � ,.•/ FP- 1 . 0 s7.1,7: \ Ai �€ (-2. - mm'i. �--_� � (-; PENDENTCSPRINKMERU HEAD DETAIL a3 \- FIRE PROTECTION INSTALLATION PARTIAL FIRST FLOOR PLAN 3 `-' j`-""'~""-"-""' €! n FP-1.O SCALE:1/4"=1'-O" !� C(�MMEI�T : e o �� I FP-1.0 SCALE: N.T.S. 14. li J 'yE GENERAL NOTES IPCVS 1. ALL SYMBOLS ARE GENERIC AND MAY NOT BE APPLICABLE TO THIS PROJECT. 2. COORDINATE ALL DEVICE LOCATIONS WITH THE WORK OF OTHER TRADES. REVIEW ARCHITECTURAL, MECHANICAL AND ALL OTHER DRAWINGS TO VERIFY DETAILS THAT MAY CONFLICT WITH ELECTRICAL EQUIPMENT OR DEVICES. Health 3. ALL DEVICES SHALL BE FLUSH MOUNTED WITH CONCEALED WIRING, UNLESS OTHERWISE NOTED. ALL CONDUIT SHALL BE RECESSED IN FLOORS, CEILINGS, AND/OR WALLS OR WITHIN MECHANICAL ROOMS, UNLESS OTHERWISE NOTED. 4. ALL CIRCUITS SHALL BE (2) #12 THHN/THWN 90"C WITH (1) #12 GND IN 3/4" CONDUIT UNLESS OTHERWISE NOTED ON THE DRAWINGS, INDICATED IN THE EQUIPMENT SCHEDULE OR REQUIRED TO REDUCE VOLTAGE DROP. REFER TO SPECIFICATION FOR CONDUIT TYPE IN SPECIFIC PROJECT AREAS. STORE NUMBER . 5. DASHED ELECTRICAL ITEMS ARE EXISTING TO BE REMOVED AND LEGALLY DISPOSED OF. CORAM, INC. Ley m 7358 S W DURHAM RD. i.e. PORTLAND, OR 97224 6. LIGHT SCALE ELECTRICAL ITEMS ARE EXISTING TO REMAIN AND BE REUSED. PROJECT TtPE PHAR ACY i.e. DEAL TYPE IPPR 7. BOLD ELECTRICAL ITEMS SHALL BE PROVIDED AND INSTALLED BY THE CONTRACTOR. CS PROJECT NUMBER 0106369 • i.e. 9 ARCHITECT OF RECORD ABBREVIATIONS A AMPERE kAIC KILO—AMPERE INTERRUPTING CAPACITY AC ALTERNATING CURRENT LTFC LIQUID TIGHT FLEXIBLE CONDUIT AHU AIR HANDLING UNIT MAX MAXIMUM AUX AUXILIARY MCA MINIMUM CIRCUIT AMPS AWG AMERICAN WIRE GAUGE MCB MAIN CIRCUIT BREAKER BLDG BUILDING MIN MINIMUM C CONDUIT MLO MAIN LUG ONLY CB CIRCUIT BREAKER NEC NATIONAL ELECTRICAL CODE CKT CIRCUIT N NEUTRAL CONDUCTOR CU CONDENSING UNIT NF NON—FUSED DISC SW DISCONNECT SWITCH NIC NOT IN CONTRACT DWG DRAWING NPR NEGATIVE PRESSURE ROOM CONSULTANT: EF EXHAUST FAN NTS NOT TO SCALE EMT ELECTRICAL METALLIC TUBING P POLE ER EXISTING TO BE RELOCATED PH PHASE ETR EXISTING TO REMAIN RGS RIGID GALVANIZED STEEL CONDUIT ( e.:;:.,.' Sta nte c FCU FAN COIL UNIT RHC REHEAT COIL UNIT FFU FAN FILTER UNIT RM ROOM FS FORGED STEEL RTU ROOF TOP UNIT Stantec G/GND GROUND TYP TYPICAL 111 GRANT AVENUE SUITE 201 GFI GROUND FAULT INTERRUPTER UL UNDERWRITER LABORATORY HP HORSE POWER ENDICOTT, NY 13760 JB JUNCTION BOX V VOLTS kW KILO—WATT W WIRE Tel. (607)-321-6100 WP WEATHERPROOF www.stantec.com PROJECT#191001405 i .. 1 DEVELOPER LIGHTING SYMBOLS EXISTING 2x4 LAY—IN LUMINAIRE \ NEW 2x4 LAY—IN LED LUMINAIRE EXISTING 2x4 FAN FILTER HEPA DIFFUSER 1111 NEW 2x4 FAN FILTER HEPA DIFFUSER EXISTING 2x2 LAY—IN DIFFUSER a b INBOARD/OUTBOARD FIXTURE LIGHT SWITCHES r SEAL: POWER PLAN SYMBOLS �Ep PROFF HOME RUN TO PANELBOARD 0 DUPLEX RECEPTACLE �'� irk BRANCH CIRCUIT WIRING 4 DOUBLE DUPLEX RECEPTACLE + HARDWIRE POWER CONNECTION TO I rAf wi 30 AMP 120 VAC TWIST—LOCK f Gi , e kb, EQUIPMENT RECEPTACLE ef9+ .cam. g,215, tee x X= EQUIPMENT SCHEDULE POWER OUTLET CONNECTION DC DOMED CAMERA (CEILING MOUNT) 9ir0• PE IDENTIFIER [WT WIRELESS TRANSMITTER OT 120 VOLT THERMOSTAT O SMOKE DETECTOR REVISIONS: F.' FUSIBLE DISCONNECT SWITCH Q DUCT MOUNTED SMOKE DETECTOR ASD 1I ISSUE FOR BID/PERMIT 06/06/2017 [-1 NON—FUSIBLE DISCONNECT SWITCHEli FA AUDIO/ALARM EP COMBINATION FUSED DISCONNECT SWITCH AND MOTOR STARTER 7 DATA OUTLET (2—CAT6 JACKS) RECESSED SURFACE t1 L POWER OR LIGHTING PANEL r CIRCUITING EXAMPLES a, PANEL DESIGNATI CIRCUIT PANEL DESIGNATI CIRCUIT DRAWING BY: 0 i —0 PNL—A/3 -e 3 1 PNL—A/3 I 13 DATE: JUNE 06, 2017 o CIRCUIT # CIRCUIT # JOB NUMBER: 2016285.50 1. ELECTRICAL DEVICES AND LIGHT FIXTURES SHALL BE CIRCUITED TO THE PANEL AND CIRCUIT # AS INDICATED IN TITLE: PORTLAND "RENOVATIONS" E .T THESE EXAMPLES PER GENERAL NOTE 4 ABOVE. IF PANEL DESIGNATION IS NOT PRESENT AT DEVICE OR FIXTURE Si SEE DRAWING GENERAL NOTES. ..---iiio ELECTRICAL 5 N 0 2. IN SOME CASES HOMERUNS AND BRANCH CIRCUITRY MAY BE INDICATED AS SHOWN BELOW AND SHALL BE LEAD SHEET 1 CIRCUITED AS INDICATED IN THE PREVIOUS EXAMPLE. C+N -as PNL—A/3 PNL—A/3 SHEET NUMBER: 3. MAJOR MECHANICAL AND ELECTRICAL EQUIPMENT SHALL BE CIRCUITED AS INDICATED ON THE EQUIPMENT SCHEDULES E-O . 1 1AD ELECTRICAL SINGLE LINE POWER DIAGRAMS. MAJOR EQUIPMENT INCLUDES PANELS, SWITCHGEAR, SWITCHBOARDS, -a Ae_ TRANSFORMERS, AIR HANDLING UNITS, PUMPS, ETC. wq :LE II C�MIu�EI�FS`-"-""-e" "`..e"A EI II E 0 PART 1 —GENERAL PART 3 — EXECUTION 12) PROVIDE APPLICABLE INSTALLATION AND MAINTENANCE MANUALS. 1) ABBREVIATIONS 1) ALL WORK SHALL BE PERFORMED IN A NEAT AND WORKMANLIKE MANNER; ALIGN, LEVEL AND a. THE ELECTRICAL CONTRACTOR IS EXPECTED TO BE FAMILIAR WITH THE TERMS AND 13) LIST OF EQUIPMENT AND SYSTEMS REQUIRING SHOP DRAWINGS AND DATA SUBMITTALS; ADJUST FOR SATISFACTORY OPERATION; INSTALL SO THAT CONNECTING AND DISCONNECTING OF ABBREVIATIONS USED IN THE TRADE, SUCH AS GND, AWG, UL, ETC. IN THE EVENT THAT ANY CONDUIT AND ACCESSORIES CAN BE MADE READILY, AND SO THAT ALL PARTS ARE EASILYIP CVS ABBREVIATION USED IN THESE SPECIFICATIONS IS NOT CLEAR TO THE CONTRACTOR, HE a. ALL WIRE, CABLE AND CONDUIT. ACCESSIBLE FOR INSPECTION, MAINTENANCE, AND REPAIR. SHOULD REQUEST CLARIFICATION DURING THE BIDDING PERIOD. THE FAILURE TO UNDERSTAND b. COMBINATION STARTERS, SAFETY SWITCHES AND FUSES. ANY SUCH TERM OR ABBREVIATION SHALL NOT BE USED AS A BASIS FOR A CHANGE IN COST. c. CIRCUIT BREAKERS, BREAKERS AND ACCESSORIES. 2) RACEWAY INSTALLATION GENERAL REQUIREMENTS: 2) REGULATIONS, CODES, AND FEES d. LIGHTING FIXTURES. a. MINIMUM CONDUIT SIZE SHALL BE 3/4 INCH FOR POWER AND 1/2 INCH FOR LOW VOLTAGE a. COMPLY WITH ALL APPLICABLE OSHA, FEDERAL, STATE, AND MUNICIPAL LAWS AND CONTROL SYSTEMS. REGULATIONS. 14) PROJECT RECORD DOCUMENTS (AS-BUILTS); PRIOR TO APPLICATION FOR FINAL PAYMENT, b. SUPPORT OUTLET BOXES, PULL BOXES, AND JUNCTION BOXES SEPARATELY FROM BUILDING Health b. ADDITIONAL REGULATIONS INCLUDE, BUT ARE NOT LIMITED TO: ELECTRICAL CONTRACTOR SHALL SUBMIT COMPLETE AND LEGIBLE PROJECT RECORD DOCUMENTS. CONSTRUCTION, NOT FROM CONDUIT. IN ADDITION TO OTHER REQUIRED INFORMATION, THESE DOCUMENTS SHALL REFLECT ALL FIELD c. SECURELY SUPPORT CONDUIT FROM BUILDING CONSTRUCTION. CHANGES AND SHOW BRANCH CIRCUIT CONNECTIONS ON PANEL SCHEDULES AND CIRCUIT OR d. DO NOT EXPOSE CONDUIT IN FINISHED ROOMS UNLESS CALLED FOR. 1. AMERICAN SOCIETY FOR TESTING MATERIALS (ASTM). WIRING NUMBERS CHANGED OR ASSIGNED DURING CONSTRUCTION. DOCUMENTS, WITH ANY e. WHERE EXPOSED CONDUIT IS PERMITTED, INSTALL CONDUIT PARALLEL TO CEILINGS, WALLS 2. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI). CHANGES OR MODIFICATIONS CLEARLY INDICATED, TO INCLUDE BUT NOT BE LIMITED TO THE AND FLOORS IN NEAT AND ORGANIZED CONFIGURATIONS. ALL CONDUITS IN OPEN JOIST 3. INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE). FOLLOWING: AREAS SHALL BE RUN ALONG THE UNDERSIDE OF THE ROOF JOISTS. STORE 4. INSULATED POWER CABLE ENGINEERS ASSOCIATION (IPCEA). a. POWER AND EQUIPMENT PLANS. f. COORDINATE ALL CONDUIT RUNS WITH OTHER TRADES IN ADVANCE OF INSTALLATION. , 5. NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION (NEMA). g. WHERE SEVERAL CONDUITS ARE INSTALLED TOGETHER, SUPPORT FROM CHANNEL SYSTEM AND CORAM, INC. 6. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA). CLAMP TO THE BOTTOM WHERE POSSIBLE. 7. NATIONAL ELECTRICAL CODE, NFPA NO. 70 - LATEST EDITION. h. REAM CONDUIT ENDS BEFORE INSTALLATION. 7358 S W DURHAM RD. 8. OTHER PUBLICATIONS INCLUDED IN "NATIONAL FIRE CODES", PUBLISHED BY NFPA. i. PLUG CONDUIT OPENINGS UNTIL WIRES ARE INSTALLED. PORTLAND, OR 97224 9. NATIONAL ELECTRICAL SAFETY CODE ANSI-C2, LATEST EDITION, IEEE STANDARDS. j. DO NOT INSTALL ADJACENT TO OR ON HOT SURFACES. PROJECT TYPE PHAINACY 10. LOCAL ELECTRICAL CODE. 3) BRANCH CIRCUITS: DEAL TYPE P 11. LOCAL UTILITY STANDARDS. PART 2—PRODUCTS a. UNLESS OTHERWISE NOTED, ALL NEW BRANCH CIRCUITS INDICATED ON THE DRAWINGS SHALL 12. UNDERWRITERS LABORATORIES (UL). 1) ELECTRICAL EQUIPMENT AND MATERIALS BE (2) #12'S (1) #12 GND IN A '4" C. CS 13. AMERICANS WITH DISABILITIES ACT (ADA). a. ALL PRODUCTS AND MATERIALS SHALL BE NEW UNLESS OTHERWISE INDICATED. b. ALL BRANCH CIRCUITS SHALL HAVE A SEPARATE NEUTRAL CONDUCTOR. NO SHARED PROJECT 0106369 ■ 14. INTERNATIONAL BUILDING CODE (IBC), LATEST EDITION. b. WHERE ELECTRICAL ITEMS ARE INDICATED TO BE REMOVED AND REUSED, THE ELECTRICAL NEUTRALS ALLOWED. 15. NFPA-70E CONTRACTOR SHALL TAKE ALL PRECAUTION TO SALVAGE THE ITEM AND RETAIN ITS PRESENT pp��� RECORD CLEAN ROOM REQUIREMENTS AND CVS-CORAM STANDARDS. CONDITION. REPORT DAMAGE TO ANY DEMOLISHED ITEM SCHEDULED FOR REUSE TO THE 4) CONDUIT DROPS TO MOTORS AND EQUIPMENT: ARCHITECT OF RECORD 17. BUILDING CODE OF STATE OF OREGON. ARCHITECT/ENGINEER IMMEDIATELY. a. PROVIDE RGS CONDUIT TO WITHIN 3 FEET OF EQUIPMENT. 18. CITY OF PORTLAND, OREGON BUILDING CODE; TITLE 26 - ELECTRICAL REGULATIONS. c. IT IS THE INTENT OF THIS CONTRACT THAT ALL MATERIAL AND/OR EQUIPMENT OF THE SAME b. EXTEND TO MOTOR WITH LFMC. CATEGORY SHALL BE OF THE SAME MANUFACTURER, OR IN THE CASE OF SPECIAL SYSTEMS c. WHERE MOTOR OR EQUIPMENT IS WITHIN 3 FEET OF CEILING, SUPPORT CONDUIT BEND c. EACH ITEM OF EQUIPMENT AND MATERIAL SHALL CONFORM TO REQUIREMENTS OF THESE WHICH ARE A COMPOSITE OF A NUMBER OF MANUFACTURERS' PRODUCTS, SHALL BE AGAINST TWISTING, EXTEND FMC OR LFMC TO CONDUIT MOTOR. APPLICABLE PUBLICATIONS WHICH MAKE THEM MOST SUITABLE IN THE OPINION OF THE SUPPLIED AND/OR SERVICED FROM AN ORGANIZATION WITH ONE SOURCE OF RESPONSIBILITY. ARCHITECT/ENGINEER FOR ENVIRONMENTAL CONDITIONS WHERE THEY SHALL BE INSTALLED. 5) PROVIDE GREEN GROUND WIRE IN ALL RACEWAYS. d. APPROVAL OF ITEMS, WHETHER EVIDENCED BY SEAL, LABEL, OR STAMP, SHALL NOT ABSOLVE 2) EQUIPMENT AND ACCESSORIES MAY BE SPECIFICALLY DESIGNATED OR IDENTIFIED BY CONTRACTOR FROM COMPLIANCE WITH REQUIREMENTS OF CONTRACT DOCUMENTS. MANUFACTURER'S CATALOG NUMBERS ON THE DRAWINGS. WHERE NO MANUFACTURER'S NAME 6) SEAL ALL CONDUIT PENETRATIONS THROUGH WALLS AND CEILINGS. e. SECURE NECESSARY PERMITS AND PAY ALL REQUIRED FEES APPLICABLE TO THE WORK IN OR MODEL NUMBER IS SPECIFIED, EQUIPMENT SUBMITTED MUST BE DESIGNED IN CONFORMITY a. PROVIDE JUNCTION POINTS ON EITHER SIDE OF PENETRATION AND USED AN APPROVED DIVISION 26. WITH APPLICABLE TECHNICAL STANDARDS, SUITABLE FOR MAXIMUM WORKING LOADS, AND SHALL THERMAL, WATERTIGHT SEALANT. 3) INSPECTION: OBTAIN LOCAL ELECTRICAL INSPECTION CERTIFICATE AND RECEIPT FOR INSPECTION, HAVE A NEAT AND FINISHED APPEARANCE. ALL MATERIAL SPECIFIED BY MANUFACTURER'S NAME 7) RACEWAYS IN INDOOR DRY LOCATIONS; DELIVER TO THE ARCHITECT/ENGINEER BEFORE APPLICATION FOR FINAL PAYMENT. AND/OR MODEL NUMBER IS TO BE CONSIDERED THE STANDARD OF QUALITY FOR POTENTIAL a. EMT WITH STEEL SET SCREW FITTINGS-CONCEALED IN GENERAL OFFICE AREAS OR EXPOSED IN SUBSTITUTIONS. FOR ITEMS OF MATERIAL AND EQUIPMENT WHICH ARE LISTED BY MECHANICAL ROOMS AND OPEN DAY AREAS. 4) INTENT: IT IS THE GENERAL INTENT OF THE DRAWINGS AND THESE SPECIFICATIONS THAT THE MANUFACTURERS NAMES/MODEL NUMBERS AND WHERE THE WORDS "OR APPROVED EQUAL" b. FMC OR MC CABLE-FINAL CONNECTION TO LIGHT FIXTURES IN LENGTHS LESS THAN 6'. ELECTRICAL CONTRACTOR FURNISHES AND INSTALLS COMPLETE, OPERATIONAL SYSTEMS IN APPEAR, THEY ARE INTENDED TO INDICATE GENERAL TYPE AND QUALITY REQUIRED. THE c. LFMC-FINAL CONNECTION TO ALL MOTORS. COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS AND TO THE SATISFACTION OF THE ARCHITECT/ENGINEER'S DECISION AS TO QUALITY AND RELATIVE MERIT SHALL BE FINAL. d. FMC-FINAL CONNECTION TO EQUIPMENT (EXCEPT MOTORS) WHERE FLEXIBLE CONNECTION IS ARCHITECT/ENGINEER AND OWNER. ELECTRICAL WORK SHALL INCLUDE THE FURNISHING OF 3) OBTAIN FROM THE MANUFACTURER, PRINTED INSTALLATION INSTRUCTIONS AND WIRING DIAGRAMS CALLED FOR. CONSULTANT: LABOR, MATERIALS, TOOLS, EQUIPMENT, TRANSPORTATION, PERMITS, INSPECTION FEES, SERVICES, TO AID IN PROPERLY EXECUTING WORK INSTALLATION WHERE APPLICABLE, ESPECIALLY TO AND ALL NECESSARY RELATED ITEMS REQUIRED. 8) RACEWAYS OUTDOORS; ENSURE THAT MANUFACTURER'S WARRANTY SHALL BE APPLICABLE. a. RGS ABOVE AND BELOW GRADE. 5) ELECTRICAL EQUIPMENT AND SYSTEMS - BRIEF SCOPE: AS OR VIBRATION 4) ALL ELECTRICAL EQUIPMENT SHALL OPERATE WITHOUT OBJECTIONABLE NOISE , a. LIGHTING AND POWER BRANCH CIRCUITS. 9) SUPPORT FLEXIBLE METAL CONDUIT EVERY 4-1/2 FEET OR CLOSER AND WITHIN 12 INCHES OF tantec b. CONDUIT, WIREWAYS, WIRING, OUTLETS, SWITCHES, ETC. DETERMINED BY ARCHITECT/ENGINEER. MAKE NECESSARY MODIFICATIONS OR REPLACEMENTS AS OUTLET BOXES PER CODE. c. MOTOR STARTERS & DISC. SWS - WHERE REQUIRED BY THE CODE OR INDICATED ON DWGS. APPROVED, WITHOUT EXTRA COST TO THE OWNER. d. LUMINAIRES AND LAMPS. 10) MAXIMUM LENGTH OF FLEXIBLE CONDUIT SHALL BE 36 INCHES EXCEPT THAT FROM OUTLET BOX Stantec e. DATA CONDUIT/CABLE AS INDICATED ON THE DRAWINGS. 5) EQUIPMENT SUPPLIERS AND MANUFACTURERS TO LIGHTING FIXTURE WHERE UP TO SIX FEET LENGTH IS PERMITTED. f. GROUNDING - WHERE REQUIRED BY THE CODE OR INDICATED ON THE DRAWING. a. MAJOR EQUIPMENT OR SYSTEMS SHALL BE INSTALLED UNDER THE DIRECT SUPERVISION OF A 111 GRANT AVENUE SUITE 201 FACTORY AUTHORIZED SALES AND SERVICE AGENT. 11) WHERE HORIZONTAL CONDUIT RUNS PIERCE BLOCK WALLS, PROVIDE RIGID STEEL CONDUIT 6) ELECTRICAL EQUIPMENT SPECIFIED IN OTHER DIVISIONS. b. SUPPLIER SHALL MAINTAIN AN ADEQUATE SUPPLY OF SPARE PARTS AND HAVE TECHNICAL SLEEVES, CAULK SLEEVES AND CONDUIT TO FORM WATERTIGHT SEALS WHERE ENTERING ENDICOTT, NY 13760 a. INTENT: IT IS THE INTENT OF THESE SPECIFICATIONS THAT THE CONTRACTOR SHALL PROVIDE PERSONNEL AVAILABLE TO MAKE REPAIRS TO SYSTEMS WITHIN TWENTY-FOUR (24) HOURS DAMP AREAS. Tel, (607)-321-6100 THE POWER SUPPLY WIRING FROM THE PANEL THROUGH THE LINE SIDE OF MOTOR AFTER THEY ARE NOTIFIED BY OWNER. www.stantec.com PROJECT#191001405 CONTROLLERS (IF REQUIRED) AND FROM THE LOAD CONTACTS OF THE CONTROLLERS TO THE C. SHOP DRAWINGS SHALL BE DISAPPROVED IF NOT ACCOMPANIED BY PROOF THAT THE 12) FOR FIRE RATED 1 HOUR, 2 HOUR, OR 3 HOUR WALLS PROVIDE: MOTORS OR OTHER LOADS, UNLESS SPECIFICALLY NOTED OTHERWISE. WHERE THE POWER FOREGOING HAS BEEN COMPLIED WITH. a. FIRE RESISTANT SEALANT COMPOUND BETWEEN CONDUIT AND SLEEVE. SUPPLY CIRCUIT IS ALSO THE CONTROL CIRCUIT, SUCH AS WOULD BE THE CASE IN A UNIT HEATER WITH A LINE VOLTAGE THERMOSTAT, A WATER HEATER WITH A LINE VOLTAGE 6) CONDUIT AND RACEWAYS; ALL TYPES BELOW SHALL BE UL CATEGORIZED AS RACEWAY 13) SHEETROCK WALL PENETRATIONS: DEVELOPER AQUASTAT, ETC., THE WIRING SHALL BE INCLUDED BY THIS CONTRACTOR. INDICATED (IDENTIFIED ON UL LISTING MARK AS RACEWAY INDICATED). SEE THE EXECUTION a. WHERE SINGLE HORIZONTAL CONDUIT RUNS PIERCE FIRE RATED SHEETROCK WALLS, DRILL OR b. CONTROL WIRING CIRCUIT(S) AT ANY VOLTAGE, WHEN NOT PART OF POWER WIRING AND SECTION FOR APPROVED RACEWAYS IN SPECIFIC AREAS. CUT HOLE IN SHEETROCK WITHIN ±1/4 INCH OF CONDUIT OUTSIDE DIAMETER (O.D.). ISOLATED WITH CONTROL POWER TRANSFORMERS AND/OR INTERPOSING RELAYS, SHALL BE a. EMT-ELECTRICAL METALLIC TUBING; STEEL, GALVANIZED ON THE OUTSIDE AND ENAMELED ON b. WHERE MULTIPLE HORIZONTAL CONDUIT RUNS PIERCE FIRE RATED SHEETROCK WALLS PROVIDE PROVIDED BY THIS CONTRACTOR. THE INSIDE, BY ALLIED TUBE & CONDUIT CORP., LTV COPPERWELD, OR WHEATLAND TUBE CO. FIRE STOP WALL FRAMES AND CONDUIT SUPPORT SYSTEMS. SEAL THESE OPENINGS WITH c. REFER TO SITE DEVELOPMENT, ARCHITECTURAL, STRUCTURAL, MECHANICAL SYSTEMS DRAWINGS b. RGS-RIGID GALVANIZED STEEL; STEEL, HOT DIPPED GALVANIZED ON THE OUTSIDE AND INSIDE, PLIABLE FIRE RESISTANT SEALANT. REPAIR WALL OPENINGS AND FINISH WITH JOINT FOR OTHER INFORMATION AND DETAILS RELATING TO THIS CONTRACTORS WORK. BY ALLIED TUBE & CONDUIT CORP., LTV COPPERWELD, OR WHEATLAND TUBE CO. TREATMENT COMPOUND. SAND AND FINISH TO MATCH GENERAL CONSTRUCTION. d. PROVIDE DISCONNECT SWITCHES WHERE REQUIRED BY THE CODE AND AS INDICATED ON c. FMC-FLEXIBLE METALLIC CONDUIT; GALVANIZED STEEL STRIP SHAPED INTO INTERLOCKING DRAWINGS. CONVOLUTIONS, TYPE RW, BY AFC CABLE SYSTEMS INC., ANAMET ELECTRICAL INC., 14) INSTALLATION OF CONDUCTORS AND CABLES e. RECEIVE AND STORE CONTROLLING EQUIPMENT AS NECESSARY AND BE RESPONSIBLE FOR ELECTRI-FLEX CO., OR INTERNATIONAL METAL HOSE CO. a. USE MANUFACTURER-APPROVED PULLING COMPOUND OR LUBRICANT WHERE NECESSARY; PROPER SIZING OF THERMAL TRIP UNITS. UNLESS OTHERWISE NOTED, ALL MOTOR d. LFMC-LIQUIDTIGHT FLEXIBLE METAL CONDUIT; (SPECIFICALLY MARKED WITH TEMPERATURE AND COMPOUND USED MUST NOT DETERIORATE CONDUCTOR OR INSULATION. DO NOT EXCEED CONTROLLERS SHALL BE INSTALLED BY THE ELECTRICAL CONTRACTOR. ENVIRONMENT APPLICATION DATA), BY AFC CABLE SYSTEMS INC., ANAMET ELECTRICAL INC., MANUFACTURER'S RECOMMENDED MAXIMUM PULLING TENSIONS AND SIDEWALL PRESSURE ELECTRI-FLEX CO., OR UNIVERSAL METAL HOSE CO. VALUES. 7) TESTS e. FOR ALL RACEWAY SYSTEMS PROVIDE FITTINGS, JUNCTION BOXES AND ACCESSORIES APPROVED b. USE PULLING MEANS, INCLUDING FISH TAPE, CABLE, ROPE, AND BASKET-WEAVE WIRE/CABLE a. SCHEDULE ALL TESTS AS SOON AS EACH PART OF THE WIRING SYSTEM IS COMPLETE AND FOR USE WITH THAT PARTICULAR SYSTEM. GRIPS THAT WILL NOT DAMAGE CABLES OR RACEWAY. BEFORE IT IS ENERGIZED. SEAL: b. ALL TEST EQUIPMENT AND SET-UP SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. 7) ELECTRIC POWER WIRING: 15) LABEL PANELS AND CIRCUITS PER NEC SECTION 408. c. CHECK FOR LOAD BALANCE AMONG PHASES ON ALL LIGHTING OR PANEL FEEDERS AND a. GENERAL: RATED 600V, 90'C, NFPA 70 TYPE THHN/THWN. COPPER ONLY. PROre CORRECT PHASE IMBALANCE IMMEDIATELY. b. INTERLOCKED FLEXIBLE GALVANIZED STEEL ARMOR SHEATH, CONFORMING TO UL REQUIREMENTS 16) IDENTIFY AND COLOR-CODE CONDUCTORS AND CABLES: ���E� `� ° d. CORRECT DEFECTIVE EQUIPMENT OR WORKMANSHIP IMMEDIATELY. FOR TYPE MC METAL CLAD CABLE. INSULATED COPPER CONDUCTORS, SUITABLE FOR 600 � ` e. WIRING SYSTEMS-600 VOLTS OR LESS-ALL CONDUCTORS OF ALL SYSTEMS, INCLUDING SIGNAL VOLTS, RATED 90'C, ONE OF THE TYPES LISTED IN NFPA 70 TABLE 310-13 OR OF A TYPE a• POWER-CIRCUIT CONDUCTOR IDENTIFICATION, 600 V OR LESS: FOR CONDUCTORS IN VAULTS,AND COMMUNICATIONS SYSTEMS SHALL BE TESTED FOR OPENS, SHORTS, AND GROUNDS. IDENTIFIED FOR USE IN TYPE MC CABLE. INTERNAL FULL SIZE COPPER GROUND CONDUCTOR PULL AND JUNCTION BOXES, USE COLOR-CODING CONDUCTOR TAPE TO IDENTIFY THE PHASE.f. GROUNDING SYSTEMS WITH GREEN INSULATION. ACCEPTABLE COMPANIES: AFC CABLE SYSTEMS INC., COLEMAN b. COLOR SHALL BE FACTORY APPLIED FOR SIZES LARGER THAN N0. 8 AWG. tad CABLE CO. MC CABLE CONNECTORS: AFC FITTING INC.'S AFC SERIES, ARLINGTON INDUSTRIES c. IDENTIFY CIRCUITS IRAJUNCTIONUMBOXES AND PANELS WITH PRE-MANUFACTURED ADHESIVE TAGS INDICATING CIRCUIT NUMBER. �y A� ,0� 4a'irr � AO' 1. WHEN APPLICABLE, CHECK SYSTEM NEUTRALS AND EQUIPMENT GROUNDING CONDUCTORS INC.'S SADDLE GRIP, OR THOMAS Sc BETTS CO.'S TITE-BITE WITH ANTI-SHORT BUSHINGS. d. MARK ALL JUNCTION BOX COVERS WITH APPROVED MARKER OR LABEL. INDICATE CIRCUIT '9,9 -8,2 OJ SEPARATELY FOR OPENS, SHORTS, AND UNINTENTIONAL GROUNDS BEFORE INTERCONNECTION c. FIRE ALARM CABLING SHALL BE UL LISTED AND LABELED AS COMPLYING WITH NFPA 70, NUMBERS AND SOURCE PANEL. INDICATE IF CIRCUITS ARE FROM AN EMERGENCY POWER 11 O• PEG'I TO THE GROUNDING SYSTEM. ARTICLE 760. SOURCE. PAINT ALL FIRE ALARM COVERS RED. MARK SECURITY, DATA, AND PA SYSTEMS 8) DEMONSTRATE THAT ALL EMERGENCY CIRCUITS AND LIGHTING ARE OPERATIVE BY INTERRUPTING APPROPRIATELY. 8) CONDUIT CHANNEL SUPPORT SYSTEMS: THE "NORMAL" POWER TO EACH UNIT OR SYSTEM AS APPLICABLE. a. 12 GAGE GALVANIZED STEEL CHANNEL AND ACCESSORIES; B-LINE SYSTEM INC.'S B-22 17) COLORS FOR 208/120-V CIRCUITS: (1 -5/8 X 1-5/8 INCHES), B-12 (1-5/8 X 2-7/16 INCHES), B-11 (1 -5/8 X 3-1/4 a. PHASE A: BLACK. 9) LIGHTING AND POWER SYSTEMS INCHES), KINDORF/T&B CORP.'S 8-900 (1 -1/2 X 1-1/2 INCHES), B-901 (1 -1/2 X b. PHASE B: RED. REVISIONS: a. DEMONSTRATE THAT ALL LUMINAIRES WILL OPERATE. 1 -7/8 INCHES), B-902 (1 -1/2 X 3 INCHES). c. PHASE C: BLUE. b. DEMONSTRATE THAT ALL LIGHTING SWITCHES, CONTACTORS, TIMERS, PHOTOELECTRIC CONTROLS, d. NEUTRAL: WHITE. 1Q ISSUE FOR BID/PERMIT 06/06/2017 b. GALVANIZED STEEL 90 ANGLE IRON-SIZED TO ACCOMMODATE CONDUIT(S) BEING SUPPORTED. ETC., AS APPLICABLE, WILL OPERATE AS INTENDED BY THE DRAWINGS AND SPECIFICATIONS. c. DEMONSTRATE THAT ALL POWER EQUIPMENT, RECEPTACLES AND OTHER RELATED ITEMS WILL 9) PANELBOARDS: PROVIDE WITH RATINGS AND CIRCUIT BREAKERS AS INDICATED ON PANEL 18) COLORS FOR 480/277-V CIRCUITS: OPERATE AS INTENDED BY THE DRAWINGS AND SPECIFICATIONS. a. PHASE A: BROWN. SCHEDULE. PANEL AND BREAKERS SHALL BE FULLY RATED , NEMA 1 WITH HINGED COVERS 10) THE CONTRACTOR SHALL OBTAIN WRITTEN RECEIPTS AS APPLICABLE FROM THE OWNER'S AND FACTORY FINISH. b. PHASE B: RANGE. Y AUTHORIZED REPRESENTATIVE FOR EACH OF THE FOLLOWING ITEMS OR SYSTEMS LISTED BELOW: a. MANUFACTURER: SQUARE 'D' OR APPROVED EQUAL. C. PHASE C: YELLOW. a. INSTRUCTION OF OWNER'S AUTHORIZED REPRESENTATIVES. b. INCOMING MAINS LOCATION: TOP. d. NEUTRAL: GRAY. ,. ., c. PHASE, NEUTRAL AND GROUND BUSES: COPPER. b. BOUND COPIES OF WIRING DIAGRAMS, CATALOG CUTS , MAINTENANCE INSTRUCTIONS, SPARE 19) DEVICE IDENTIFICATION: d. CONDUCTOR CONNECTORS: MECHANICAL TYPE. PARTS LISTS, ETC. a. IDENTIFY ANY NEW RECEPTACLES, SWITCHES WITH AN APPROVED LABEL MAKING DEVICE WITH c. GUARANTEE AND SERVICE CONTRACT. e. PANELBOARD SHORT CIRCUIT RATINGS: AS INDICATED ON PANEL SCHEDULE. BLACK LETTERS ON A WHITE BACKGROUND. f. EQUIPMENT GROUND BAR: SOLIDLY BONDED COPPER. d. SPARE FUSES. g. NAMEPLATES: CONTAIN CATALOG NUMBER, FACTORY ORDER NUMBER, VOLTAGE, AMPERAGE b. PROVIDE PANEL AND CIRCUIT NUMBER FOR RECEPTACLES AND SWITCHES. 11) SUBMITTALS RATING AND PHASES. a. SHOP DRAWINGS AND DESCRIPTIVE DATA SHALL INCLUDE ALL PERTINENT INFORMATION SUCH h. CURRENT CARRYING PARTS: ALL CURRENT CARRYING PARTS SHALL BE INSULATED FROM 20) ELECTRICAL CONNECTIONS AS DIMENSIONS, MANUFACTURER, CAPACITY, TYPE CURVES, CERTIFICATION, ACCESSORIES, GROUND AND PHASE-TO-PHASE BY HIGH DIELECTRIC STRENGTH THERMOPLASTIC. a. TIGHTEN ELECTRICAL CONNECTORS AND TERMINALS ACCORDING TO MANUFACTURER'S PHYSICAL AND PERFORMANCE DATA, FINISHES, MATERIALS, LOCATION, AND COMPLETE WIRING PUBLISHED TORQUE-TIGHTENING VALUES. IF MANUFACTURER'S TORQUE VALUES ARE NOT DIAGRAMS FOR EACH SYSTEM. WIRING DIAGRAMS SPECIFICALLY MADE AND/OR CORRECTED 10) LIGHT SWITCHES: INDICATED, USE THOSE SPECIFIED IN UL 486A AND UL 4868. FOR THIS PROPOSAL INCLUDE ALL THE PUBLISHED LITERATURE ABOUT THE PRODUCT OR a. FLUSH-MOUNT 20 AMP, TOGGLE TYPE, 120/277 VAC RATED, QUIET OPERATION, SPECIFICATION b. MAKE SPLICES AND TAPS THAT ARE COMPATIBLE WITH CONDUCTOR MATERIAL AND THAT E SYSTEM(S). GRADE, MOLDED BASE AND COVER CAP WITH SIDE AND BACK TERMINAL SCREW CONNECTIONS POSSESS EQUIVALENT OR BETTER MECHANICAL STRENGTH AND INSULATION RATINGS THAN o b. WHEN A PROPOSED EQUIVALENT IS SUBMITTED FOR APPROVAL, CONTRACTOR SHALL ENSURE HUBBELL #1221 OR EQUAL. UNSPLICED CONDUCTORS.71 DRAWING BY: THAT ALL DETAILED CHARACTERISTICS OF THE EQUIPMENT EQUAL OR EXCEED THE CATALOG CHARACTERISTICS OF EQUIPMENT SPECIFIED, WHETHER SPECIFICALLY INDICATED IN THE o 1 1) FIRE ALARM WIRE AND CABLING: PROVIDE UL LISTED AND LABELED AS COMPLYING WITH 21) HANGERS AND SUPPORTS. DATE: JUNE 06, 2017 , SPECIFICATION OR NOT. DEVIATIONS FROM THE SPECIFIED ITEM SHALL BE CLEARLY EXPLAINED a. FURNISH ALL FASTENERS AND HARDWARE COMPATIBLE WITH THE MATERIALS AND METHODS c IN THE SUBMITTAL. NFPA 70, ARTICLE 760 AND UL 1424. COMPLY WITH UL 2196 FOR 2-HOUR RATING. REQUIRED FOR ATTACHMENT OF SUPPORTING DEVICES. c. CLEARLY IDENTIFY EACH SEPARATE ITEM SUBMITTED BY JOB NAME, SECTION NUMBER, a. SIGNALING WIRE CIRCUITS SHALL BE TWISTED, SHIELDED PAIR, NOT LESS THAN NO. 18 AWG. JOB NUMBER: 2016285.50 b. NON-POWER LIMITED CIRCUITS SHALL BE SOLID COPPER CONDUCTORS WITH 600 VOLT RATED, b. COMPLY WITH NECA 1 AND NECA 101 FOR APPLICATION OF HANGERS AND SUPPORTS FOR PARAGRAPH NUMBER, AND SPECIFIC ITEM NUMBER WHERE APPLICABLE. ELECTRICAL "RENOVATIONS" CONTRACTOR SHALL BE RESPONSIBLE FOR DIMENSIONS TO BE CONFIRMED AT JOB SITE TO 75 DEGREE C, COLOR-CODED INSULATION. ELECTRICAL EQUIPMENT AND SYSTEMS. TITLE: PORTLAND M �' c. ALL HARDWARE SHALL BE GALVANIZED AND CORROSION RESISTANT. ENSURE THAT ITEMS TO BE FURNISHED FIT THE SPACE AVAILABLE, AND ACCORDINGLY ORDER 1. LOW-VOLTAGE CIRCUITS: NO. 16 AWG, MINIMUM. cv d. SPACE SUPPORTS FOR RACEWAYS AS REQUIRED BY NFPA 70. 2. NO. 12 AWG SUCH EQUIPMENT THAT FINAL INSTALLATION SUITS THE TRUE INTENT OF THE CONTRACT LINE-VOLTAGE CIRCUITS: MINIMUM. e. GALVANIZED THREADED ROD SIZE SHALL BE 1/4, 3/8 OR 1/2 INCH IN DIAMETER AS ELECTRICAL 5.▪ c-! S DRAWINGS. ar d. IF EQUIPMENT REQUIRING DIFFERENT ARRANGEMENT OF CONNECTIONS FROM THOSE SHOWN IS REQUIRED FOR WEIGHT OF CONDUITS. SPECIFICATIONS a�a APPROVED , IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO FURNISH REVISED LAYOUTS, 22) WIRE TERMINATIONS: __`Ain INSTALL EQUIPMENT TO OPERATE PROPERLY IN HARMONY WITH CONTRACT INTENT, AND MAKE a. FOR CONDUCTORS NO. 10 AWG OR SMALLER: USE TERMINALS FOR CONNECTING WIRING TO SHEET NUMBER: 0▪0$g ALL CHANGES IN WORK REQUIRED BY NEW ARRANGEMENTS OF CONNECTIONS COORDINATE • S CONTROL AND POWER WIRING WITH OTHER TRADES AND PAY FOR ANY CHANGES SO IMPOSED. EQUIPMENT DESIGNED FOR USE WITH TERMINALS. b. FOR CONDUCTORS NO. 8 AWG OR LARGER: USE COMPRESSION OR MECHANICAL TYPE LUGS E- O c A a COPIES OF THESE CHANGES SHALL BE SENT TO THE ARCHITECT/ENGINEER. FOR CONNECTING CABLES TO FLAT BUS BARS OR CONNECTING CABLES TO EQUIPMENT 1 • `J v ,;� e. SUBSTITUTIONS FOR EQUIPMENT LISTED WITHIN SPECIFICATIONS OR CONTRACT DRAWINGS ARE DESIGNED FOR USE WITH LUGS. Z 0 TO BE DONE IN WRITING TO THE OWNER'S ARCHITECT/ENGINEER. ANY INCREASE IN COSTS TO s..._..-: .._...-c.,-..........--,....,--...----,..-----,.......-I o OTHER CONTRACTORS CAUSED BY AN APPROVED SUBSTITUTION SHALL BE BORN BY THIS 23) FIRE ALARM SYSTEM MODIFICATIONS: C 5i,l))EI'S: e ii ii E CONTRACTOR. MAINTAIN EXISTING SYSTEM AT ALL TIMES. COORDINATE ALL WORK WITH A FACILITY REPRESENTATIVE BEFORE ANY REQUIRED SHUTDOWNS OR MODIFICATIONS. = ;a da. (s.: , GENERAL NOTES (1) 2 4 T ii THISP ROOM I 1 24'-6" 1. WHERE THE TERM "REMOVE AND REINSTALL" !S USED IN THE DOCUMENTS IT SHALL MEAN THE FOLLOWING: - A) REMOVAL OF EXISTING RACEWAYS AND ALL CONDUCTORS WITHIN. © B) INSTALLATION OF NEW RACEWAYS AND CONDUCTORS TO MATCH EXISTING. I © o , 2. THIS DEMOLITION DRAWING IS IN PART DIAGRAMMATIC AND THE CONTRACTOR SHALL VISIT EACH I LOCATION TO DETERMINE THE ACTUAL DEMOLITION SCOPE. _ ___ _ ____ _ EXISTING 3. FIELD VERIFY EXISTING CIRCUITS BEFORE COMMENCING REMOVALS. PROVIDE COPY OF PANELBOARD I I� -!- - r - 5�1 EPANEL 'L1 ' SCHEDULES TO ENGINEER PRIOR TO START OF NEW ELECTRICAL WORK. 'H eCalfl t Sh I / II 'Cn II .' \\\ �_-\_� {NP 3 I `��J L--\ I / �� � (TYP. 9) PANEL �L2' 4. ALL FEEDER AND BRANCH CIRCUITS LEFT SPARE BY REMOVALS SHALL BE LABELED SPARE AT \ THIS ROOM I� �I © I I I I / I THIS ROOM I SOURCE AND ON PANELBOARD SCHEDULES. �/ \\ \ :II 1, _4I ROOM I I I / I O EXISTING I ,C I - I I PANEL 'W' S. ALL WIRING SHALL BE REMOVED BACK TO SOURCE OR NEAREST DEVICE TO REMAIN AS INDICATED ON TI?. OF 5 \ l I I (S '>0� - - I - �--- G "- THE DRAWINGS. POWER SHALL BE TERMINATED IN A WORKMANLIKE AND APPROVED MANNER. STORE NUMBER II (THIS ROOM \`\\ CD.9) 15!)c 1 �` P,� I r:-- 1 EXISTING k7 �I 101 CORAM, INC. \ %.9.9.,.\ I C_- PANEL 'L' 6. COORDINATE SHUTDOWNS WITH PROJECT ENGINEERING MANAGER AND SERVICE CENTER MANAGER. 0 \_... . . ♦ _ _ _ E 1 _ �— 7358 S W DURHAM RD. • \ I I -/ I ` IH (c) �-- L. - I 7. UNLESS OTHERWISE NOTED ALL NEW BRANCH CIRCUITS SHALL BE (2) #12, #12 GND IN 3/4" EMT) ___, PORTLAND, OR 97224 .. \-41 I —/ CONDUIT. F' Cr PHAFLIACY ____ _ . \--- J _. — I / II u� II I / / / � .m__-^T 8. ALL NEW BRANCH CONDUITS SHALL HAVE A SEPARATE NEUTRAL CONDUCTOR. NO SHARED NEUTRALS PROJECT TYPE / I — I . In- I / I ! / 1 ALLOWED. DEAL TYPE IfR L----� V_ _V_ !—_ l / / / I k.-_II _ 9. ALL FIRE ALARM SYSTEM RE-PROGRAMMING AND TESTING SHALL BE DONE BY THE BUILDING FIRE ALARM 0106369 ASD -� T -- 1 I , I SERVICE CONTRACTOR. CONTACT CVS-CORAM MANAGER OR BUILDING LANDLORD. r "--,-------1 2 / $ 1 10. PRIOR TO START OF CONSTRUCTION, CONTRACTOR SHALL PROVIDE MINIMUM 30-DAY, 24-HOUR LOAD I` I \ I I II (TYP. 9) O Lj;.PC3S41-1-11 kN I STUDY OF EXISTING PANEL BOARDS FOR METERING AND RECORDING PEAK CURRENT LOADS AND ARCHI�CT \ I THIS ROOM AVERAGE POWER DEMAND OVER 15 MINUTE INTERVALS. PROVIDE REPORT TO ENGINEER PRIOR TO l OF RECORD \H - ----- -� L ---J L----� -- --� - © -�I �� START OF CONSTRUCTION. J� I / • - ,, I _lir ' _ - - - - -- - II �n II / I�,-Kic��ii // I I / I DEMOLITION KEYED NOTES I ��\ I I ` I I \ II I�/—�1 I I / IkN I / Ir' I / I 0 DISCONNECT (3) PREP ROOM FFUs, (1) ANTE ROOM FFU AND (9) COMPOUNDING ROOM FFUs. TAG - -- -. ----- L----�I - ._ - \ �. .I II (-,-) � I / 11(7—\AI / ROOM I / I F CIRCUIT WIRES FOR REUSE PER INSTALLATION PLAN 2/E-1.1 I N I I N� II I I — —� V_-�---j .. _ _ J ; 1 I 40 ``U I / O REMOVE DUCT MOUNTED SMOKE DETECTOR FOR RTU-5 AND (2) CEILING MOUNTED SMOKE DETECTORS _ _ , I / I 1 4 I _L,I \-LSI ` SHOWN. SAVE FOR REUSE PER INSTALLATION PLAN THIS SHEET. TAG CONDUCTORS FOR RECONNECTING 1 CRC. I I/ I I K-n 1 i KCJS I PER INSTALLATION PLAN. SI�cU E 1 �� I I �;�- . COOLER I � I II V� II 11 VN II 1c, �I i qq Vr. L-__� _ 1 �; � K-r-/ • k1 / -'\ I 1k'—'�1 O REMOVE (1 1) PREP ROOM 2' X 4' LIGHT FIXTURES, AND (1) ANTE ROOM 2' X 4' LIGHT FIXTURE C104 I i I �!2_'J I *-_- --1 N-....----r--±--- .. - SHOWN. TAG WIRING FOR REUSE PER INSTALLATION PLAN 2/E-1.1. I I / I i I / I 1 1,,_,,, 4 DISCONNECT, REMOVE AND SAVE (9) CLEAN ROOM RATED COMPOUNDING ROOM 2' X 4' LIGHT FIXTURES 7 sivioe .____ I I I I I O I / I I I / I II �Cn I _�_ __L �J—- __�_ SHOWN FOR REUSE PER INSTALLATION PLAN 2/E-1.1. TAG CIRCUIT WIRES FOR REUSE PER I �'`/���''� ' I I I / I I / I II �� � r-'� � —���—� �-�1 INSTALLATION PLAN 2/E-1.1 . CONSULTANT: -._ __._' ___ .� :4.: �_.__.I �...�, IL_.J 11'7-'�I I u� I I I u� I I I u� I I I u� I -- - — _� _� 'k_1--��� __ O DISCONNECT, REMOVE AND SAVE CAMERAS SHOWN. TAG WIRING FOR CONNECTING RE-INSTALLED I L J i_. _. � � CAMERAS PER INSTALLATION PLAN 2/E-1.1. " O DISCONNECT, REMOVE AND SAVE EXIT LIGHTS. TAG CIRCLET WIRES FOR REUSE PER INSTALLATION PLAN 1 /� o �_ �, II I I I II 2/E-1 .1. 11 I IP - - - - -- 4 Jj \ ` II r O7 DISCONNECT AND REMOVE SAVE CEILING MOUNTED DUPLEX RECEPTACLE WITH BOX, AND DATA PORT 4, Stantec I / ,- - WITH BOX SHOWN. TAG RECEPTACLE CIRCUIT CONDUCTORS AND DATA CABLING FOR REUSE PER Stantec 1 1 GRANT AVENUE SUITE 201 I INSTALLATION PLAN 2/E-1 .1. __ ENDICOTT, NY 13760 D - - _ __ _. ____-_ _ I $O DISCONNECT (5) STORAGE ROOM 2'x4' LIGHT FIXTURES AND SAVE FOR REUSE PER INSTALLATION PLAN Tel. {607)-321-6100 I \�\ I I 2/E-1 .1. TAG CIRCUIT WIRES FOR REUSE PER INSTALLATION PLAN ON THIS DRAWING. .J www stanteC.COr PROJECT#191001405 • ri- ELECTRICAL DEMOLITION PARTIAL FIRST FLOOR PLAN INSTALLATION KEYED NOTES I E-1.1SCALE: 1/4"=1'-O" O CONNECT EXISTING CIRCUITRY TAGGED PER DEMOLITION PLAN 1/E-1.0 TO (18) NEW FFUs SHOWN. DEVELOPER: �� V EXTEND AND CONNECT CIRCUIT WHIPS FROM COMPOUNDING ROOM TO ACCOMMODATE THE ADDITIONAL FFUs IN THE PREP ROOM. PROVIDE MOTOR TERMINAL SWITCH FOR EACH FFU. c1--) ``: ( cn• © PROVIDE (7) PREP ROOM 2' X 4' LIGHT FIXTURES, (1) ANTE ROOM 2' X 4' LIGHT FIXTURE AND (1) 2 ' 4 5 ; VEST. ROOM 2' X 4' LIGHT FIXTURE AS SHOWN. ALL LIGHT FIXTURES SHALL HAVE AN ISO 7 CLEAN (TYP. 7) 0 --4--- ROOM CLASSIFICATION. CONNECT EXISTING CIRCUITRY TAGGED PER DEMOLITION PLAN 1/E-1.1. REFER TO I (TYP. 2) (NP' 2) THIS ROOM (TYP. 2) 2 LIGHTING FIXTURE SCHEDULE ON E-2.0 FOR ADDITIONAL INFORMATION. ALL FIXTURES ARE TYPE 'F1' THIS ROOM THIS OM © THIS ROOM UNLESS NOTED OTHERWISE. LIGHTING IN THE NPR AREA PROVIDED BY ROOM VENDOR. o 'L1'/24 0 0 -- I © REINSTALL (9) COMPOUNDING ROOM 2' X 4' CLEAN ROOM LIGHT FIXTURES (SAVED FROM DEMOLITION) { -- --. I - _ -r-_- - - AND CONNECT TAGGED CIRCUIT WIRES EXTENDING WHIPS AS REQUIRED TO LOCATIONS AS I ` R�NTE .� --- GFl tom—•— — "'". --�'"4 ,---1-7]. .�--' ._ __-.__ SHOWN. f-`' I 1 C;. l 4 onom ... - 0 REINSTALL DUCT MOUNTED SMOKE DETECTOR AND (2) CEILING MOUNT SMOKE DETECTORS (SAVED FROM _ TYP. 3 ® - EXISTING A� � { ) HC 06�.Ham' 20,22,24 - (NP 9) PANEL 'L1 ' DEMOLITION) AND CONNECT INTO EXISTING FIRE ALARM INITIATION CIRCUIT UTILIZING TAGGED CABLING SEAL EDp11UF THIS ROOM 'L1 '/21 rig 1� �`"� IIM THIS ROOM {2)#10, REMAINING PER DEMOLITION. CONTRACTOR SHALL HIRE THE FIRE ALARM SYSTEM REPRESENTATIVE FOR ' 1 F�',p Ll (1�)#10GND, lEXISTINGRE PROGRAMMING AND TESTING OF THE FERE ALARM SYSTEM UPON COMPLETION OF INSTALLATION. �`' �(,IN �� O -, l " © 1CONDUITI PANEL 'L2' EXISTING FIRE ALARM CONTROL PANES_ (FACP), LOCATED AT THE MAIN ELECTRIC/TELECOM ROOM, ISAQ I �. �'o W (TYP. OF 4) 'L1' 18 EXISTINGHONEYWELL FIRE ALARM CONTROL PANEL, MANUFACTURED BY HONEYWELL. DUCT MOUNTED SMOKE I „ PANEL 'H' DETECTOR TO INITEATE SHUTDOWN OF RTU-1 UPON SENSING OF SMOKE WITHIN THE RETURN DUCT VIA b� r rL /38 � O I _ --- o ��� 1 0 ir ' S CONTROL MODULE IN FACP. PRIOR TO SYSTEM INTERRUPTION OR SHUTDOWN, CONTACT PAC TRUST AT .c�� � "� � �h � tu €' (TYP.) EXISTING (503) 624-7787. PROVIDE NEW SAMPLING TUBE SIZED PER NEW DUCTWORK AND COORDINATE WITH HVAC 14)4.�B•g�'� O,� o \'� ®:44\14\:4P-4,*:A#107, ♦� Ailk 1 s PANEL 'L CONTRACTOR. �. PEC+/ 4„ TWSPROOM 'HA'/8,10,12 ►�� -- Iln I ' (5) PROVIDE NEMA L5-30R 30 AMP, 125 VOLT RATED RECEPTACLE AND FLUSH-MOUNT IN DEVICE BOX WITHiiw ASD oC BAKE' EDS CARD H�F ____. II 01 �� I I I RECEPTACCLEGASKETED Y ON ILIZECE WINDOWRMULLIONTE AT AS REH NEW UIRED.HOOD LOCATION PROVIDE CIRCUITRO AS INDICATED. CORDNATEWN AT 48" AFF TO CENTER OF 0 \ (TYP. 2) QTHIS ROOM ' „ L.,. RECEPTACLE LOCATIONS WITH ARCHITECTURAL AND MECHANICAL DRAWINGS PRIOR TO INSTALLATION. / „ ' � 0 RHC 10T 0 I � � I � o PROVIDE 480/277 VOLT, 3-PHASE, 4-WIRE PANEL 'HA' AND MOUNT ON WALL SHOWN. PROVIDE PANEL FEEDER FROM 100 AMP, 3-POLE BREAKER IN EXISTING PANEL 'H' AS NOTED. REFER TO PANEL REVISIONS: \ 0----_1_ ILII _- I m ' j SCHEDULES ON DRAWING E-2.0. " „ PW1c� 1 ISSUE FOR BID/PERMIT 06/06/2017 \ ..\/ • ' , /., 4�. PROVIDE POWER FEED TO MECHANICAL EQUIPMENT IN LOCATIONS INDICATED. REFER TO POWER OUTLET ,5, ►— 111M ER 0 Ail 1 o SCHEDULE AND PANEL SCHEDULES ON DRAWING E-2.0 FOR ADDITIONAL INFORMATION. 0F IW \, �O \ • (_4_)/ I PROVIDE NEW LIGHTING CONTROL IN PREP, COMPOUNDING AND STORAGE ROOMS BY REPLACING EXISTING / HA/7,9,1 1 �RHg-102 El-Q-100 ';t----------41) / \ 1 0 LIGHTING CONTROL WITH NEW INBOARD/OUTBOARD A/B SWITCH CONTROL AS SHOWN. ALL FIXTURES \ i TYP. 5 I i EXCEPT THOSE LABELED 'F1 E' SHALL BE CONTROLLED IN ORDER THAT OUTSIDE LAMPS ARE MANUALLY RC)i 11 I I ' ` HIS ROOM I = I ENERGIZED BY SWITCH a AND INSIDE LAMPS BY SWITCH b . L1 '/19 �� . ® , ��4 0 RO M a PROVIDE (2)#12, (1)#12 OND. IN 3/4" CONDUIT FROM EXISTING FFU 120 VOLT CIRCUIT TO SPEED i 1 ...9,..._) ,,,,,.. ® ,.\ 41 'L1 /20 'HA'/2,4,6 1 E 0 0 'LLJ1 CONTROLLER. 1 � F1 E L1'/22 \CY id .. _ - _. ill \ \ ! w o REINSTALL AND CONNECT CAMERAS IN NEW CEILING. WIRES WERE TAGGED PER DEMOLITION PLAN 1/E-1.1. K- /X(/ X 1 w 11 REINSTALL AND CONNECT EXIT LIGHT IN NEW LOCATION SHOWN. CIRCUIT WIRES TAGGED PER DEMOLITION _ ST' S �' `� 0 a PLAN 1/E-1.1 . = ....._ ...___. / 104 r / 1 ® PROVIDE NEMA 5-20R WHETS DUPLEX RECEPTACLE AND DATA PORT WITH WHITE FACE PLATE AND SEALED ta 0 \VA I Fl E I j CEILING MOUNTED BOXES. EXTEND AND CONNECT TAGGED CIRCUIT CONDUCTORS TO RECEPTACLE AND _-- ____ - o -- — I TAGGED CABLING TO DATA PORT. DRAWING BY: 1 41 (TYP ) AKER EDGEGIARD HF BAKER EDGEGARD HF INI - - O �'�' 0 PROVIDE NEMA 5 20R WHITE DUPLEX RECEPTACLE AND FLUSH MOUNT IN DEVICE BOX WITH GASKETED DATE: JUNE 06, 2017 cra • — -- -- F1 E STAINLESS STEEL FACE COVER PLATE AT EACH NEW HOOD LOCATION SHOWN AT 48" AFF TO CENTER 3e i LJ L _ RECEPTACLE. PROVIDE CIRCUITRY AS INDICATED. COORDINATE RECEPTACLE LOCATIONS WITH ARCHITECTURAL JOB NUMBER: 2016285.50 I I II AND MECHANICAL DRAWINGS PRIOR TO INSTALLATION. .____________4_,...__-._ -- TITLE PORTLAND "RENOVATIONS" a �' (TYP.) O ---- 0 REINSTALL (5) STORAGE ROOM 2' X 4' CLEAN ROOM LIGHT FIXTURES (SAVED FROM DEMOLITION) AND PO LAN 7. i'' III i CONNECT TAGGED CIRCUIT WIRES EXTENDING WHIPS AS REQUIRED TO LOCATIONS AS SHOWN. PROVIDE (1) ELECTRICAL DEMO INSTALL .-.co0 ,I11.1: : O I i STORAGE ROOM 2 X 4 LIGHT FIXTURES (TYPE F1 E) AS SHOWN. ALL LIGHT FIXTURES SHALL HAVE AN DEMO/ INSTALL N. 'L1 '/17 'L1'/15 I ISO 7 CLEAN ROOM CLASSIFICATION. CONNECT EXISTING CIRCUITRY TAGGED PER DEMOLITION PLAN PARTIAL FIRST FLOOR PLANS o �. NEW PANEL HA O EXISTING 1/E-1.1 . REFER TO LIGHTING FIXTURE SCHEDULE ON E-2.0 FOR ADDITIONAL INFORMATION. 5 N g �\ \ O FFU SPEED 0 PROVIDE NEMA 5-20R WHITE DUPLEX RECEPTACLE AND FLUSH-MOUNT IN DEVICE BOX WITH GASKETEDLc SHEET NUMBER: CONTROLLER STAINLESS STEEL FACE COVER PLATE AT EACH FRIDGE LOCATION SHOWN AT 18" AFF TO CENTER c , va \\ (1)#6GND, 2 EMT TO PANEL 1 f RECEPTACLE. PROVIDE CIRCUITRY AS INDICATED. COORDINATE RECEPTACLE LOCATIONS WITH ARCHITECTURAL E- 2 1\\ \ , ' 'H /19,21,23 AND MECHANICAL DRAWINGS PRIOR TO INSTALLATION. • 1 m 11 � �� 1 0 PROVIDE NEMA 5-20R WHITE DUPLEX GFI RECEPTACLE AND FLUSH-MOUNT IN DEVICE BOX WITH C'MNIuv vv��ti.e .. E °i ELECTRICAL INSTALLATION PARTIAL FIRST FLOOR PLAN _ ' GASKETED STAINLESS STEEL FACE COVER PLATE AT SUMP PUMP LOCATION. PROVIDE CIRCUITRY S: 6E-1.1 SCALE: 1/4"-1'-0" I, I AS INDICATED. COORDINATE RECEPTACLE LOCATIONS WITH ARCHITECTURAL AND MECHANICAL DRAWINGS � c _ � L L PRIOR TO INSTALLATIQN, 1 2 3 C4) (r- --..\ ,CVS GENERAL NOTES 1. WHERE THE TERM "REMOVE AND REINSTALL" IS USED IN THE DOCUMENTS IT SHALL MEAN THE FOLLOWING: _ _ A) REMOVAL OF EXISTING RACEWAYS AND ALL CONDUCTORS WITHIN. B) INSTALLATION OF NEW RACEWAYS AND CONDUCTORS TO MATCH EXISTING. TO PANEL 11:1-- I 0 I "H'/19,21,23 �- 2. THIS DEMOLITION DRAWING IS IN PART DIAGRAMMATIC AND THE CONTRACTOR SHALL VISIT EACH LOCATION TO DETERMINE THE ACTUAL DEMOLITION SCOPE. FT EXIST I I RTU Health \ I 3. FIELD VERIFY EXISTING CIRCUITS BEFORE COMMENCING REMOVALS. PROVIDE COPY OF \ PANELBOARD SCHEDULES TO ENGINEER PRIOR TO START OF NEW ELECTRICAL WORK. STORE NUMI3ER r( D 1 I _ _ _ _ 4. ALL FEEDER AND BRANCH CIRCUITS LEFT SPARE BY REMOVALS SHALL BE LABELED CORAM, INC. f _N ` 'L - - SPARE AT SOURCE AND ON PANELBOARD SCHEDULES. 7358 S W DURHAM RD. O5I 7 _1___ PORTLAND, OR 97224 . ALL POWER SOURCES SHALL BE REMOVED BACK TO SOURCE OR NEAREST DEVICE TO REMAIN AS INDICATED ON THE DRAWINGS. POWER SHALL BE TERMINATED IN APRO {'r'TTYPE� PFIAF�IAIt'Y WORKMANLIKE AND APPROVED MANNER. DEAL TE NPR \ 6. COORDINATE SHUTDOWNS WITH OWNER'S LOCAL REPRESENTATIVE. \ \ C$ P�(;T 0106369 \\, \ I I 7. UNLESS OTHERWISE NOTED ALL NEW BRANCH CIRCUITS SHALL BE (2) #12, #12 GND IN \\ 3/4" EMT CONDUIT. 8. ALL NEW BRANCH CONDUITS SHALL HAVE A SEPARATE NEUTRAL CONDUCTOR. NO SHARED ARCHITECT OF RECORD V I NEUTRALS ALLOWED. \ 9. COORDINATE FIRE ALARM DEVICE TERMINATIONS AND RE-PROGRAMMING OF FIRE ALARM I - - - I I CONTROL PANEL WITH THE BUILDING FIRE ALARM SYSTEM SERVICE VENDOR. N \ I 1 10. PRIOR TO START OF CONSTRUCTION, CONTRACTOR SHALL PROVIDE MINIMUM 30-DAY, 24-HOUR LOAD STUDY OF EXISTING PANEL BOARDS FOR METERING AND RECORDING PEAK CURRENT LOADS AND AVERAGE POWER DEMAND OVER 15 MINUTE INTERVALS. \ I I PROVIDE REPORT TO ENGINEER PRIOR TO START OF CONSTRUCTION. \ I II J I Ir '..'N I I II DEMOLITION KEYED NOTES CONSULTANT: \ 1 - Ol REMOVE FEEDER FOR ROOF TOP UNIT RTU-1 TO SOURCE AS INDICATED. _J - - _ _ _ _ - c jp-- - Stantec I OUTLIN E OF CLEAN ROOM SPACES BELOW FOR REFERENCE Stantec 1 1 1 GRANT AVENUE SUITE 201 ENDICOTT, NY 13760 D — — — — — -- _,r__ } Tel. (607)-321-6100 I I I www.stantec.com PROJECT#191001405 1 (-1- ] ELECTRICAL DEMOLITION PARTIAL ROOF PLAN! E-1.2 SCALE:1/4"=1'-0" �.-___... ._ _�____._._ __._ _ 01741. DEVELOPER ,\. CD 0 CLO 1. 0 PANEL 'L'/41 / _ _ _.._ _ - - © PANEL 'HA'/14,16,18 SEAL: / 1 WP ��1 E / GFI PANEL 1 I ����p PNOf,�+A I^ CP 'HA'/1,3,5 Or OA , L _ _ _ _ _ _ �� �G � 9 (0270) / .�-. I �. ill /„.„ , ,,, RTU-2 GFl ,�S s l��^ I�_II WP r�i� ir .x,99 s Zo�441 0 ID / _ . _ __ ,„,... 0 / / . 7.4 © / / \ PANEL 'L'/7- [/ I \, 1 \ RTU-1 I INSTALLATION KEYED NOTES REVISIONS: \\ / / `ISSUE FOR BID/PERMIT 06/06/2017 \ / \ O PROVIDE POWER FEED TO MECHANICAL EQUIPMENT IN LOCATIONS INDICATED. REFER \ I TO POWER OUTLET SCHEDULE AND PANEL SCHEDULES ON DRAWING E-2.0 FOR \ R--� ADDITIONAL INFORMATION. \ i \ I i-V / f - - - 1 --y I © PROVIDE BRANCH CIRCUIT FOR NEW ROOFTOP GFI RECEPTACLE WITH WEATHERPROOF \/ �,..f, /-.;,1' ENCLOSURE AS SHOWN. ROUTE CIRCUITRY THRU DUCT OPENING TO PANEL BELOW. / , ,.f. 41,;;;,0, ;f... .. EXHAUST FAN CIRCUIT SHALL BE CONTROLLED VIA WALL SWITCH IN NEGATIVE E� �`:" ,��*. I PRESSURE ROOM AND INTERLOCKED WITH BUBBLE TIGHT DAMPER. OPANEL V/38 I I I I 00 ea it I Cl I I 1 11 DRAWING BY: II DATE: JUNE 06, 2017 _i it JOB NUMBER: 2016285.50 TITLE: PORTLAND "RENOVATIONS" Zir- 1 I OUTLINE OF CLEAN ROOM SPACES I ELECTRICAL DEMO/INSTALL �^ BELOW FOR REFERENCE 5`.1s PARTIAL ROOF PLANS gr- fr.N LE g D — — _ — _ h _ SHEET NUMBER: . g I 11 E- 1 . 2 a ELECTRICAL INSTALLATION PARTIAL ROOF PLAN N .. i? " E-1.2 5CALE:1/4"=1'-0" NC�MI�EI�f T...7....-„,.......-.-.........-.---... ��vvU.�Uv�e II Ii E �/ -- GC y . � 61 KEYED NOTES (T) PRIOR TO DISCONNECTING RTU-1 HVAC UNIT, VERIFY BREAKER FEEDING UNIT IN EXISTING PANEL 'H'. UPON REMOVAL OF CIRCUITRY, LABEL CIRCUIT BREAKER AS "SPARE" (FED RTU-1 CLEAN ROOM 100). AP CVS POWER OUTLET SCHEDULE © CONNECT FFU-1 CIRCUITRY TO EXISTING BREAKER #18 IN PANEL 'L'. © Pg01NDpA NEL 301 AMP,ONNEOCTEEQUIPMCIRCUIENT AT S INDICATEDD AND INSTALL IN SPACES # 13,15,17 AND HealthI 1LOCATION CONTROLLER STARTER CONTROLLER SERVICE TAG# DESCRIPTION VOLTAGEPHASE LOAD FEED CKT BKR FUSE CONDUIT&WIRE CONTROLLER TYPE SIZE ACCESSORIES DISCONNECT REMARKS 0 REMOVE EXISTING SPARE 20 AMP, 3—POLE CIRCUIT BREAKER #19,21,23 IN PANEL 'H'. PROVIDE 150 AMP, 3—POLE 'SPECTRA' RMS—E CIRCUIT BREAKER IN SAME SPACES AND ROOF TOP UNIT RTU-1 ROOF 480/3 46.0 MCA PANEL'HA'/1,3,5 50/3 3-#8&1-#10G IN 1"EMT INTNFD NA NA INTIDISC NON-FUSED DISCONNECT SWITCH PROVIDED BY MANFACTURER ON UNIT PROVIDE PANEL FEEDER TO NEW PANEL 'HA' AS INDICATED. REFER TO ONE—LINE DIAGRAM ON E-2.1 FOR MORE INFORMATION. REFER TO DRAWING E-1.1 FOR PANEL LOCATION. STORE NUMBER ROOF TOP UNIT RTU-2 ROOF 480/3 53.5 MCA PANEL'HA'114,16,18 60/3 3-#6&1-#10G IN 1"EMT INTNFDNA NA INT/DISC NON-FUSED DISCONNECT SWITCH PROVIDED BY MANFACTURER ON UNIT CORAM, • INC. - © UTILIZE SPARE 20 AMP, 1 —POLE CIRCUIT BREAKER # 7 IN PANEL 'L' AND CONNECT ROOF TOP EXHAUST EXH-1 ROOF 480/3 1 44 FLA PANEL'L'138 2011 3#12&1E#MT IN 314" NA NA DISC PROVIDE SINGLE POLE LOCKABLE DISCONNECT SVNTCH AT FAN ROOFTOP GFI RECEPTACLE CIRCUITRY AS INDICATED. 7358 S W DURHAM RD. REHEAT COIL UNIT RHC-100 COMP RM CEILING 46013 21.1 KW PANEL'HA'/2,4,6 35/3 3-#8&1-#10G IN 1"EMT NA NA NA NEMA 12 60A INT/DISC ` - ! CONNECT EQUIPMENT TO NEW PANEL 'HA' CIRCUIT BREAKERS AS INDICATED. PORTLAND, OR 97224 3-#12&1-#12GIN3/4' J PHARMACYPFOJECT TYPE: REHEAT COIL UNIT RHC-102 PREP RM CEILING 480/3 10.0 KW PANEL'HA'!7,9,11 20/3 EMT NA NA NA NEMA 12 20A INT/DISC O ALL BREAKERS SHALL BE COMPATIBLE TO THIS PANELBOARD AND SHALL MATCH RESPECTIVE DEAL TYPE NPR 3-#12&1-#12G IN 3/4" PANELBOARD MINIMUM SHORT CIRCUIT INTERRUPTING CAPACITY. - REHEAT COIL UNIT RHC-101 ANTE RM CEILING 480/3 1.2 KW PANEL'HA'1 8,10,12 20/3 EMT NA NA NA NEMA 12 20A INTIDISC RHC-106 NPR ANTE 3412&1-#12G IN HA /202224 203 NA NA NA NEMA 12 60A INT/DISC 3/4" REHEAT COIL UNIT PANEL 0 PROVIDE UPDATED PANELBOARD SCHEDULE. C8 PROJECT 0106369 i RM CEILING 480/3 3.1 KW ' ' , , / EMT PROVIDE (1) 60 AMP, 3—POLE CIRCUIT BREAKER AND INSTALL IN SPACE #14,16,18 IN 0 PANEL 'HA'. CONNECT EQUIPMENT AS INDICATED. ^T OF RE CONTROLLER TYPES: FVNRCSD-FULL VOLTAGE NON-REVERSING COMBINATION STARTER/DISCONNECT NOTES. ARCHI I 1 CORD 0 PROVIDE (1) 20 AMP, 1 POLE CIRCUIT BREAKER AND INSTALL IN SPACE #13 IN PANEL 'HA'. INTNFD-VARIABLE FREQUENCY DRIVE INTEGRAL WITH CONTROL PANEL CONNECT EQUIPMENT AS INDICATED. ACCESSORIES: m PROVIDE (1) 20 AMP, 1 POLE CIRCUIT BREAKER AND INSTALL IN SPACE #1 IN PANEL 'L'. A-480-2aVAcCONTROL xFMR,zaVAcCOIL T CONNECT ROOFTOP GFI RECEPTACLE CIRCUITRY AS INDICATED. B-RE0-RUNNING PILOT LIGHT,GREEN-OFF PILOT LIGHT ® PROVIDE (1) 20 AMP, 1 POLE CIRCUIT BREAKER AND INSTALL IN SPACE #38 IN PANEL 'L'. G HAND-OFF-AUTO SELECTOR SWITCH CONNECT TO EXHAUST FAN ON ROOF WITH LOCKABLE SWITCH AS INDICATED. D-INTERLOCK CONTACT TO SHUT-DOWN CONTROL CIRCUIT WHEN DISCONNECT SWITCH IS OPEN ® PROVIDE (1) 20 AMP, 1 POLE CIRCUIT BREAKER AND INSTALL IN SPACE #20 in PANEL 'L1 CONNECT TO RECEPTACLE AS INDICATED. 0 PROVIDE (1) 20 AMP, 1 POLE CIRCUIT BREAKER AND INSTALL IN SPACE #22 in PANEL 'L1 '. CONNECT TO RECEPTACLE AS INDICATED. ® PROVIDE (1) 20 AMP, 1 POLE CIRCUIT BREAKER AND INSTALL IN SPACE #24 in PANEL 'L1'. CONNECT TO RECEPTACLE AS INDICATED. J CONSULTANT K2)&2)1 POWER PANEL 'H' SCHEDULE (EXISTING) 7 X 8> POWER PANEL 'L ' SCHEDULE (EXISTING) 000 POWER PANEL 'HA' SCHEDULE (NEW) DESIGNATION: PANEL 'H' STYLE, GENERAL ELECTRIC 'A' SERIES DESIGNATION: PANEL L STYLE: GENERAL ELECTRIC LOAD CENTER DESIGNATION PANEL'HA' STYLE: SQUARE'D'TYPE NF Q10.---''; LC' I i il.e%WO LOCATION: OPEN OFFICE AREA NORTH WALL SERVICE: 480Y/277V 3PH 4W 400A 22kAIC LOCATION: OPEN OFFICE AREA NORTH WALL SERVICE: 208Y/120V 3PH 4W 150A 10kAIC LOCATION OPEN OFFICE AREA NORTH WALL SERVICE: 480Y/277V 3PH 4W 250A 22kAIC FRAME: 400A MOUNTING: SURFACE FRAME: 150A MOUNTING: SURFACE FRAME 250A MOUNTING SURFACE Stantec MAIN BREAKER: MLO FEED FED FROM PANEL'H' MAIN BREAKER: 400 AMP ' FEED: MAIN BREAKER: 70 AMP FEED: • 1 1 1 GRANT AVENUE SUITE 201 ' BKR.TRIP1 BKR.TRIP/ ENDICOTT, NY 13760 LOAD BKR. TRIP BKR. TRIP LOAD LOAD BKR. TRIP BKR. TRIP LOAD (;KT NO DESIGNATION LOAD WATTS POLES PHASE POLES LOAD WATTS DESIGNATION CKT NO Tel. (607)-321-6100 CKT. NO. DESIGNATION WATTS / POLES PHASE I POLES WATTS DESIGNATION CKT. NO. CKT. NO. DESIGNATION WATTS / POLES PHASE / POLES WATTS DESIGNATION CKT. NO. 1 10186 A 7033 1 2 - RHC-100 WWW.5tQf1teC.COf71 PROJECT#191001405 1 15125 A 20/1 2000 OUTSIDE LIGHTS 2 OFFICE C 3 RTU-1 10186 50/3 B 3513 7033 a0 1 ENTRY LIGHTS 800 20/1 A 20/1 540 2 COMPOUNDING ROOM RECEPTACLES 5 10186 C 7033 E3 3 TRANSFORMER 15125 70/3 B 20/1 1200 MAIN AREA LIGHTS 4 FEED PANEL L & L1 WAREHOUSE6 OFFICE 7 3334 A 400 8 3 HALL CAN LIGHTS 800 2011 B 2011 540 RECEPTACLES 4 RHC-102 PREP O DEVELOPER: 5 15125 C 20/1 1200 LIGHTS 6 9 _ ROOM 3334 20/3 B 2013 400 RHC-101 ANTE ROOM 10 5 OFFICE 540 2011 C 20/1 720 FURN PANELS 6 (-171) 11 3334 C 400 12 7 1200 A 20/1 1200 OFFICE LIGHTING 8 RECEPTACLES SOUTH OFFICE — 13 HEPA FILTERS 1250 20/1 A 15685 14 9 HVAC FEED 1200 20/3 B 20/1 2400 WATER HEATER 10 © ROOFTOP GFI FURN PANELS MID \\\ 7 180 2011 A 2011 720 8 15 B 60/3 15685 RTU-2 16 9 ) 11 1200 C - 20/1 4500 HEPA FILTERS 12 •RECEPTACLE OFFICE - v TELEPHONE OFFICE 17 C 15685 18 13 1200 A1200 14 9 540 2011 B 20/1 720 10 _ _ RECEPTACLES RECEPTACLES 19 A 1033 28 /--� 15 HVAC FEED 1200 20/3 B 20/3 1200 HVAC UNIT 16 WAREHOUSE UNIT OFFICE 21 B 20/3 1033 RHC-106 22 . fi ) 11 HEATER 240 20/1 C 20/1 720 RECEPTACLES 12 23 C 1033 24 V 17 1200 C 1200 18 19 33224 A 2400 20 13 RECEPT SOUTH 180 2011 A 1000 14 ADDITIONAL INFO_ CONNECTED LOAD 114 VA(137.43 AMPS) PANEL 'HA' OPEN OFFICE 0 21 (WAS SPARE 33224 - 15013 B 40/3 2400 HVAC UNIT 22 OFFICE RECEPTS 20/2 FREE 30VS UNIT 20A/3P) 15 540 20/1 B 1000 16 �A� 23 33224 C 2400 24 EAST SEAL: 25 16000 A 1800 26 OFFICE RECEPTS FFU CONTROL (WAS D PROF ES 27 TRANSFORMER 16000 90/3 B 30/3 1800 LAB HVAC UNIT 28 17 - EAST 'SPARE') O 540 2011 C 20/1 0 18 2 �' 11,01N4- Svy9 FEED PANEL L2 — — 19 OFFICE RECEPTS 540 20/1 A 2011 1200 BREAKROOM MW 20 29 16000 C 1800 30 EAST RECEPTACLE i ADDITIONAL INFO: CONNECTED LOAD: 228,947 VA(275.39 AMPS). BREAKERS SHALL BE COMPATIBLE TO THIS PANELBOARD AND WORK AREA BREAKROOM1 r SHALL MATCH PANELBOARD MINIMUM SHORT CIRCUIT INTERRUPTING CAPACITY. 21 RECEPTS 720 20/1 B 20/1 300 FRIDGE REC 22 O 0 '' ,y ' 8zo° mow 23 OFFICERECEPTSEPTS 720 20/1 C 20/1 720 RE OFFICE '9i9�D. PTACLES 24 • P �O EG 25 OFFICE RECEPTS OFFICE 720 20/1 A 20/1 720 26 NORTH RECEPTACLES (2)(8) POWER PANEL 'L1 ' SCHEDULE (EXISTING) 27 2160 B 20/1 360 COMPUTER ROOM 28 DESIGNATION. PANEL L1 STYLE: EATON POWERMASTER 29 HVAC UNIT ABOVE 2160 30/3 C 20/1 360 COMPUTER ROOM 30 OFFICE REVISIONS: OFFICE RECEPT LOCATION: OPEN OFFICE AREA NORTH WALL SERVICE: 208Y/120V 3PH 4W 100A 10kAIC 31 2160 A 20/1 180 EAST 32 A ISSUE FOR BID/PERMIT 06/06/2017 FRAME, 100A MOUNTING: SURFACE BREAKROOM 33 COUNTERTOP 720 20/1 B 832 CLEAN ROOM 34 MAIN BREAKER: 100 AMP FEED_ 20/2 35 BREAKROOM EXHAUST FAN 720 20/1 C 832 36 DISHWASHER _ LOAD BKR. TRIP BKR. TRIP LOAD 1 INFUSION ROOM EXHAUST FAN / CKT. NO DESIGNATION WATTS / POLES PHASE / POLES WATTS DESIGNATION CKT. NO. 37 38 COUNTERTOP REC 360 20/1 A 20/1 124 MOTORIZED DAMER 12 WAREHOUSE 720 20/1 A 20/1 360 BREAKROOM 1 2 INFUSION ROOM FREEZERS DED. COUNTER 39 RECEPTACLES 720 20/1 B 20/1 500 HVAC 40 WAREHOUSE 720 20/1 B 20/1 360 BREAKROOM 3 4 ROOFTOP GFI COMP/COPIER _ COUNTER 11 41 RECEPTACLE 180 20/1 C 20/1 500 HVAC 42 DEDICATED COMP RECEPTACLE ROOM 180 20/1 C 20/1 180 5 6 ADDITIONAL INFO: CONNECTED LOAD: 29828.3 VA (83.30 AMPS). BREAKERS SHALL BE COMPATIBLE TO THIS PANELBOARD AND RECEPTACLE112 _ SHALL MATCH PANELBOARD MINIMUM SHORT CIRCUIT INTERRUPTING CAPACITY. 7 1000 A 2011 360 RECEPT. COPY 8 ' MACH RM 112 ROOF UNIT 20/2 USE A 9 1000 B 20/1 360 WARER OGEQUAD 10 PT DRAWING BY: WAREHOUSE QUAD cI 11 ROOF RECEPTACLE 180 2011 C 20/1 360 RECEPT 12 DATE: JUNE 06, 2017 En HORIZONTAL HOOD 3 13 RECEPT 2223 30/1 A 1000 TEMPORARY 14 JOB NUMBER: 2016285.50 0 2012 BREAKROOM TITLE: PORTLAND RENOVATIONS C HORIZONTAL HOOD "RENOVATIONS" = vi 15 RECEPT2223 3011 B 1004 16a 1 , '7--' (9 17 HORIZONTAL HOOD 2223 30/1 C 3011 HORIZONTAL HOOD 18 0LIGHT FIXTURE SCHEDULE ELECTRICAL ..n c 19 EXHAUST HOOD 360 20/1 A 20/1 72RECEPT 0 LAB FRIDGE 20 0 _ SCHEDULES RECEPT0 TYPE DESCRIPTION LAMP MOUNTING MANUFACTURE/CATALOG# VOLTAGE LOAD COMMENTS E a 2X4 INSET DOOR cn-% 21 LAB FRIDGE ' 600 20/1 B 20/1 720 LAB FRIDGE 22 RECESSED KENALL / CSEDI 24 67L50K DDC 5000K COLOR TEMPERATURE WITH 82 CRI AND N F1 CLEAN ROOM LED 120/277 73 WATTS SHEET NUMBER: g GRID CEILING DV PAF PAH SYM AMF ANTIMICROBIAL FINISH ¢' MOTORIZED LUMINAIRE `� 23 20/1 C 20/1 720 SUMP PUMP GFI 24 s 5 DAMPER 15 2X4 INSET DOOR p rn RECESSED KENALL /CSEDI 24 67L50K DDC 5000K COLOR TEMPERATURE WITH 82 CRI ANDE-2 .0 ADDITIONAL INFO_ CONNECTED LOAD: 16,672 VA (46.33 AMPS). BREAKERS SHALL BE COMPATIBLE TO THIS PANELBOARD AND F1E CLEAN ROOM LED GRID CEILING 120 PAF PAH SYM AMF LEL 120/277 73 WATTS ANTIMICROBIAL FINISH AND EMERGENCY BATTERY PACK 4765 SHALL MATCH PANELBOARD MINIMUM SHORT CIRCUIT INTERRUPTING CAPACITY. LUMINAIRE m ii Ii E KEYED NOTES ,CVS OPROVIDE NEW 480Y/277 VOLT, 3-PHASE, 4-WIRE 250 AMP PANELBOARD 'HA'. REFER TO PANEL SCHEDULE ON DRAWING E-2.0 AND DRAWING E-1.1 FOR LOCATION OF NEW PANEL. O2 PROVIDE 150 AMP, 3-POLE 'SPECTRA' RMS-E CIRCUIT BREAKER IN EXISTING PANEL 'H' AND Health PROVIDE PANEL FEEDER TO NEW PANEL 'HA' AS INDICATED. REFER TO DRAWING E-1.1 FOR PANEL LOCATION. • �f =RE NUMBER CORAM, INC. 7358 S W DURHAM RD. PORTLAND, OR 97224 PROJECT TYPE PHAFIAIACY DEAL TYPE PFR (S PROJECT NUMBER 0106369 • UTILITY FEED _,. _ ARCHITECT OF RECORD Ark 4 UP • 400A/3P MCB 0 450Y/277 VOLT, 30, 4W, 400A • a —' 150A/3P © 70A/3P 90A/3P CONSULTANT: • -- (344, (1)48 GNU — (3)#3, (1)#8 CND IN 1" CONDUITiN 1 CON[�111� (10$Sta - c IV `� 48V Sta ntec 45 KVA /5 KVA 7n �� � �, 208Y/120V 1 1 1 GRANT AVENUE SUITE 201 ENDICOTT, NY 13760 © Tel. (607)-321-6100 (3)#2, (1) 2 NEUTRAL, (3) 4/0, (1) 4/0 NEUTRAL, www.stantec.com PROJECT#191001405 (3)1/0, (1)1/0 NEUTRAL, (1) 8 GND IN 1-1/4" CONDUIT (1)#2 GND IN 2" CONDUIT (146 GND IN 2" EMT DEVELOPER: PANEL. 'L.2' • (344, (1)#4 NEUTRAL.., (1)18 GND IN 1" CONDUIT 70A/3P 100A/3P MCB MCB S EAL PANEL 'HA' 480Y 277 VOLT, 30, 4W, 250A PANEL 'L' I _ PANEL 'L1' ce' GI NE s� MLOt .cc,' 1 � 1' 6 1 itt 1:9 8,20 A4;�b. PE 0 ONE—LINE DIAGRAM REVISIONS: E-2.1 SCALE: N.T.S. L ISSUE FOR BID/PERMIT 06/06/2017 DRAWING BY: LaJ DATE: JUNE 06, 2017 Cti JOB NUMBER: 2016285.50 TITLE: PORTLAND "RENOVATIONS" °- '3 11.21- - ELECTRICAL g , ONE-LINE DIAGRAM CP N SHEET NUMBER: al E-2 . 1 v C m �MIu EFTS: ��•�•�•e u u c of FIRE ALARM NOTES: SECURITY NOTES ACCESS CONTROL & VIDEO SECURITY SYMBOLS MISCELLANEOUS: 1. ELECTRICAL CONTRACTOR SHALL PROVIDE FIRE ALARM TIE-IN FOR EACH FLOOR ON SYMBOL DESCRIPTION . ,CVS EACH SECURITY PLYWOOD BACKBOARD. TIE-IN TO BE "NORMALLY CLOSED, OPEN 1. THE SECURITY CONTRACTOR IS RESPONSIBLE FOR PROVIDING, INSTALLING, - 7 EQUIPMENT TAG NUMBER, REFER TO EQUIPMENT SCHEDULE, ON ALARM" TYPE RELAY. USE 18AWG, 2-CONDUCTOR PLENUM RATED CABLE WITH TERMINATING AND CONFIGURING A FULLY OPERATIONAL SECURITY SYSTEM. ALL C#-# FIXED CAMERA "C" INDICATES COMPUTER, "T" INDICATES TELEPHONE, ETC. RED JACKET. COMPONENTS, DEVICES, CABLING, SOFTWARE AND LABOR REQUIRED SHALL BE >41 WHERE: C#-#=CAMERA FLOOR -# (E.G., C2-3 IS CAMERA 3 ON 2ND FLOOR) HC ADA DOOR OPENER - PROVIDED BY THE SECURITY CONTRACTOR, UNLESS OTHERWISE NOTED. REFER ALSO TO BOOK SPECIFICATIONS&CAMERA SCHEDULE 2. ELECTRICAL CONTRACTOR TO PROVIDE FIRE ALARM TIE-IN WITHIN A RED SURFACE - _. 0 NOTE SYMBOL, REFER TO NOTE AS INDICATED. MOUNTED JUNCTION BOX INSTALLED ON THE SECURITY PLYWOOD BACKBOARD. 2. THE SECURITY CONTRACTOR IS RESPONSIBLE FOR COORDINATING EACH TRADE'S C# PTZ CAMERA SECURITY SCOPE WITH THE GENERAL Health 3. SECURITY CONTRACTOR TO TIE-IN THE FIRE ALARM RELAY TO THE LOCK POWER ALSO RESPONSIBLE FOR COORDINATINGIFIN SH AOR. THE SECURITY ND COLOR REQUIREMENTS WITH IS I `1) WHERE: C#= CAMERA REFER ALSO TO BOOK SPECIFICATIONS&CAMERA SCHEDULE ER IC DOOR INTERCOM SECTION IDENTIFIER, INDICATING SECTION "B" ON DRAWING T0.3. A TYPICAL/SIMILAR ROOM OR AREA LAYOUT SYMBOL SUPPLY AND ACCESS CONTROL PANEL. THE ARCHITECT. - - "A" -INDICATES LAYOUT TYPE. LI 3. THE SECURITY CONTRACTOR SHALL PROTECT ALL SECURITY, SECURITY RELATED KP ALARM KEYPAD 1=I KEYBOARD MONITOR, MOUSE 1 TYPICAL LAYOUT SYMBOL- REFER TO DETAIL 1 ON DRAWING GENERAL NOTES EQUIPMENT AND CABLES ON THE PLYWOOD BACKBOARD WITHIN LOCKED JUNCTION T0.3 T0.3, UNITS CABLE INFRASTRUCTURE IS TYPICAL FOR ALL AS NOTED. BOXES, CONDUIT AND RACEWAYS. STORE NUMBER: 1. THE SCOPE OF WORK SHALL INCLUDE PROVIDING ALL WORK INDICATED, UNLESS = BAR CODE SCANNER LB LOCK DOWN BUTTON CORAM INC. SPECIFICALLY INDICATED AS WORK OF OTHER SECTIONS, OWNER OR EXISTING TO 4. THE SECURITY CONTRACTOR SHALL PROVIDE AND INSTALL ALL INTERCONNECTING © SECTION IDENTIFIER, INDICATING SECTION "B" ON DRAWING T0.3. ' • REMAIN. PROVIDE COORDINATION WITH ALL TRADES. SCOPE OF WORK IS CONDUITS AND RACEWAYS ON THE PLYWOOD BACKBOARD. 7358 S W DURHAM RD. INDICATED ON THE CONTRACT DOCUMENTS INCLUDING THE DRAWINGS AND THE - - - VW SPECIFICATIONS, WHICH ARE COMPLIMENTARY. WORK INDICATED IN ANY 5. THE SECURITY CONTRACTOR SHALL PROVIDE AND INSTALL ALL CABLE PASS-THROUGH PORTLAND, OR 97224 CONTRACT DOCUMENT SHALL BE CONSIDERED PART OF THE SCOPE OF WORK. IN HOLES IN MILLWORK. Dl BADGING WORKSTATION ML MAGNETIC LOCK © PF CT TYPE. PHARMACY GENERAL, WORK REQUIREMENTS ARE NOT INDICATED IN BOTH DOCUMENTS. DETAIL IDENTIFIER, INDICATING DETAIL NO. 2 ON DRAWING T0.3. IfFt WHERE DOCUMENTS CONFLICT WITHIN THEMSELVES OR WITH CODES AND 6. THE SECURITY CONTRACTOR SHALL PROVIDE AND INSTALL ALL OVERHEAD CABLE ® DEAL TYPE REGULATIONS, PROVIDE THE GREATER QUANTITY, HIGHER QUALITY AND FOLLOW SUPPORTED BY J-HOOKS, CABLE TRAY(PROVIDED BY OTHERS)OR EQUIVALENT. CABLE THE STRICTER REQUIREMENTS. SHALL NOT BE SUPPORTED BY CEILING GRID, DUCTWORK,SPRINKLER PIPES, I=1 BURGLAR ALARM PANEL CS PROJECT NUM 0106369 IELECTRICAL CONDUIT OR GAS PIPES.J-HOOKS ARE TO BE INSTALLED A MAXIMUM MD MOTION DETECTOR . ; 2. DRAWINGS ARE DIAGRAMMATIC ONLY. EXACT LOCATION, MOUNTING HEIGHTS FIVE FEET ON CENTER. X SECURITY DEVICE SYMBOLS WITH AN "X" LOCATED OUTSIDE SYMBOL BORDER =I INDICATES EXISTING SECURITY DEVICE THAT SHALL REMAIN AND BE INTEGRATED ,, AND ROUTING SHALL BE COORDINATED WITH ARCHITECT, GENERAL INTO NEW INSTALLATION CONTRACTOR, OTHER TRADES EQUIPMENT REQUIREMENTS AND FIELD 7. SECURITY CONTRACTOR SHALL INSTALL INFRA-RED EXIT SENSORS (PIR) WITHIN 0'-6" CS CRASH BAR WITH INTEGRAL REX 11Id INTERCOM MASTER STATION . ARCHITECT OF RECORD CONDITIONS. TO 1-0 FROM THE DOOR; WHERE APPLICABLE. 3. IN GENERAL OUTLET BOXES AND RACEWAYS WITH PULL STRINGS EXCEPT INNER 8. SECURITY CONTRACTOR TO PROVIDE GROUNDING OF ALL ELECTRONIC EQUIPMENT PHYSICAL SECURITY DRAWING LIST DUCT SHALL BE PROVIDED UNDER SECTION 16000. PROVIDE UNDER THIS SECTION ON THE PLYWOOD BACKBOARD. USE TELECOMMUNICATIONS GROUND BAR WITHIN 1=1 CARD READER WITH KEYPAD VIDEO SECURITY WALL MOUNTED MONITOR ALL PHYSICAL SECURITY EQUIPMENT, CABLING, DEVICES, FACE PLATES, ETC. FOR A MDF OR COORDINATE WITH GENERAL CONTRACTOR FOR NEAREST GROUNDING MON (PROVIDED BY SECURITY CONTRACTOR) DRAWING NUMBER DRAWING TITLE COMPLETE INSTALLED AND PERFORMANCE TESTED SYSTEM. PROVIDE OUTLET LOCATION. BOXES & RACEWAYS AS REQUIRED WHERE NOT PROVIDED UNDER 16000 OR AS PS-0.1 PHYSICAL SECURITY LEGEND INDICATED ON ELECTRICAL DRAWINGS. 9. ALL CAMERA AND CAMERA INSTALLATIONS SHALL BE FIELD COORDINATED WITH THE 1=1 CARD READER OWNER, ARCHITECT AND CONSULTANT BEFORE INSTALLATION. © INTELLIGENT CONTROL PANEL PS-2.1 PHYSICAL SECURITY SPECIFICATIONS 4. COORDINATE CABLE INSTALLATIONS WITH ALL OTHER TRADES IN ORDER TO NOT DAMAGE THE CABLES DURING CONSTRUCTION. ANY CABLE THAT IS DAMAGED 10. THE SECURITY CONTRACTOR 15 RESPONSIBLE FOR ALL CORE/WALL PENETRATIONS PS 2.1 PHYSICAL SECURITY SPECIFICATIONS DURING CONSTRUCTION SHALL NOT BE REPAIRED. IT SHALL BE COMPLETELY RELATED TO THE SECURITY SYSTEMS THAT ARE NOT SPECIFICALLY CALLED OUT ON DB DURESS BUTTON / PANIC BUTTON P-BDG BADGING PRINTER REPLACED AT NO ADDITIONAL COST TO THE OWNER, ARCHITECT OR ENGINEER. ELECTRICAL DRAWINGS UNDER SECTIONS 16000. THE SECURITY CONTRACTOR SHALL PB PS-2.1 PHYSICAL SECURITY SPECIFICATIONS USE SLEEVES WITH PROTECTIVE BUSHINGS FOR ALL PENETRATIONS THROUGH WALLS ..----.---] 5. TEST ALL EQUIPMENT AND SYSTEMS INSTALLED TO CERTIFY COMPLIANCE WITH DRAWINGS, SPECIFICATIONS, CODES, STANDARDS, LOCAL AUTHORITIES AND 11. REFER TO SHEET P5 401 & P5-402 FOR ADDITIONAL APPLICABLE INSTALLATION DC DOOR CONTACT(DOOR POSITION SENSOR) PS 3.1 PHYSICAL SECURITY CONSTRUCTION PLAN REGULATIONS. INCLUDE LABOR AND COSTS FOR REVIEWS,TESTING,APPROVALS REQUIREMENTS. PC PULL CORD PS-4.1 PHYSICAL SECURITY DETAILS AND CERTIFICATIONS. ' CONSULTANT' 6. FURNISH, INSTALL AND ASSEMBLE ALL INCIDENTAL ACCESSORIES NECESSARY TO I= DOOR RELEASE BUTTON PCS SECURITY WORKSTATION MAKE THE BUILDING PHYSICAL PROTECTION SYSTEMS WORK COMPLETE AND READY FOR OPERATION. 11 7. ALL CABLES SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER. ® EMERGENCY CALL STATION PIR INFRARED REQUEST-TO-EXIT SENSOR CABLES SHALL BE INSTALLED IN J-HOOKS OR SIMILAR PATHWAYS PARALLEL AND REX BUILT-IN REQUEST-TO-EXIT RELAY IAB Engineers+ PERPENDICULAR TO BUILDING ELEMENTS. + + EH ELECTRIC TRANSFER HINGE OC1SU lC�r�LS 8. CABLE BENDING RADIUS SHALL NOT BE LESS THAN MINIMUM REQUIRED BY EPT ELECTRIC POWER TRANSFER HINGE-VON DUPRIN OR EQUAL SA DOBERMAN INDOOR/OUTDOOR SIREN &STROBE ANSI/TIA/EIA AND BICSI. REFER TO ARCHITECTS DRAWINGS 155 SEAPORT BOULEVARD 9. PROVIDE SLEEVES WITH SMOKE AND FIRE SEALS AT ALL PENETRATIONS THROUGH SEAPORT WEST, FLOOR 2 FIRE RATED ASSEMBLIES OR FLOORS OR FULL HEIGHT(SLAB TO SLAB)WALLS. =I ELECTRIC LOCK WITH REQUEST-TO-EXIT SWITCH BOSTON, MA 02210 DC SMOKE DETECTOR COVERT CAMERA P. 617.443.4950 • F. 617.443.4959 10. PROVIDE CONDUIT SLEEVES WITH INSULATED BUSHINGS AT ALL PENETRATIONS _ - "- I THROUGH BUILDING ELEMENTS SUCH AS WALLS, SOFFITS, ETC.THAT DO NOT REQUIRE FIRE OR SMOKE SEALS. 1=1 ELECTRO-MAGNETIC DOOR HOLDING DEVICE 1=1 SERVER APPLICATION DEVELOPER' 11. WORK SHALL BE RECESSED INTO WALLS, AND INSTALLED ABOVE HUNG CEILINGS, UNLESS OTHERWISE INDICATED. ALL WORK SHALL BE INSTALLED CONCEALED WHENEVER POSSIBLE. rq VIDEO ENCODER VK VISITOR KIOSK 12. ALL CABLES THAT ARE NOT INSTALLED IN CONDUIT SHALL BE SUPPORTED DIRECTLY FROM BUILDING STRUCTURE ON APPROVED CABLE SUPPORTS. UNDER NO CIRCUMSTANCE SHALL CABLE BE INSTALLED USING CROSS BRACING, =I EMERGENCY OVERRIDE SWITCH PLUMBING/SPRINKLER PIPES, CEILING SYSTEMS OR ANY OTHER SYSTEM THAT IS VP VISITOR PRINTER NOTA SPECIFICALLY APPROVED METHOD TO INDEPENDENTLY SUPPORT TELECOM CABLES. 13. ANY SPACE ABOVE CEILINGS THAT ARE RETURN AIR PLENUMS. CONTRACTOR TO =I ELECTRIC STRIKE VI VIDEO INTERCOM PROVIDE MATERIALS AND EQUIPMENT THAT IS NRTL LISTED FOR USE IN PLENUM 14. BACKBOXES WITHIN FINISHED WALLS FOR SECURITY DEVICES SHOWN ONSEALG8 GLASS BREAK SENSOR WS WORKSTATION APPLICATION ELECTRICAL DRAWINGS. INTERIOR CAMERA SCHEDULE CAMERA# CAMERA LOCATION (INCLUDED CAMERA#AND LOCATION IN DESCRIPTION FIELD) PATCH PANEL& PORT ID (OBTAIN FROM IT CONTRACTOR) CAMERA IP ADDRESS (TO BE ASSIGNED BY CVS) COMMENTS Cl-1 NEGATIVE PRESSURE ROOM I REVISIONS: ut ISSUED FOR BID-PERMIT 06.06.17 Ncn 0 0 r-- 7 I Q CD 0 i 5 O .) cD I S -v c 0 DRAWING BY: E_ 0 c DATE: June 06, 2017 a JOB NUMBER: 02GPD-170493 0 a TITLE: c ~ e PHYSICAL SECURITY f, LEGEND N SHEET NUMBER: Y • 0n c_i CD D S > 2 a 0 Car 0 4 -g 1 ! COMMENTS: ii II E O43 l 0 5 GENERAL 8. THE SECURITY CONTRACTOR SHALL RECEIVE ONE(1)FIRE ALARM TIE-IN FROM THE FIRE ALARM THE SAME INDIVIDUAL THROUGHOUT THE COURSE OF THE PROJECT AND SHALL BE THE FEDERAL,STATE,COUNTY,AND CITY LAWS,CODES,AND REGULATIONS. F. "CENTRAL STATION": A PC WITH SOFTWARE DESIGNATED AS THE MAIN CONTROLLING PC OF THE 2 SYSTEM FOR IN EACH TEL/DATA ROOM. THE TIE-IN SHALL BE NORMALLY CLOSED,OPEN ON PERSON RESPONSIBLE FOR SYSTEM PROGRAMMING,PREPARATION OF OPERATION AND 1.16 QUALITY ASSURANCE SECURITY ACCESS SYSTEM. WHERE THIS TERM IS PRESENTED WITH INITIAL CAPITAL LETTERS,THIS ALARM CONFIGURATION,UNLESS TOLD OTHERWISE BY THE FIRE AND SAFETY SYSTEMS MAINTENANCE MANUALS,TRAINING PROGRAMS AND SCHEDULES AND TEST PROTOCOLS, DEFINITION APPLIES. _ - 1.01 RELATED DOCUMENTS CONTRACTOR. COORDINATE WITH THE MAIN CONTRACTOR AND FIRE AND SAFETY SYSTEMS DOCUMENTATION OF SYSTEM TESTING,MAINTENANCE OF RECORD DOCUMENTATION AND A. WORK SPECIFIED HEREIN SHALL BE THE RESPONSIBILITY OF A SINGLE ELECTRONIC SECURITY G. "CONTROLLER": AN INTELLIGENT PERIPHERAL CONTROL UNIT THAT USES A COMPUTER FOR _ SYSTEMS INTEGRATION CONTRACTOR. CONTROLLING ITS OPERATION. WHERE THIS TERM IS PRESENTED WITH AN INITIAL CAPITAL A. DRAWINGS,GENERAL CONDITIONS OF THE CONTRACT,CVS HEALTH AUTOMATED WEB SYSTEM CONTRACTOR,AS NECESSARY. ADDITIONAL RELAYS,CABLES,AND CONNECTIONS ARE TO BE COORDINATION AND SCHEDULING OF ALL SUBCONTRACT LABOR(AS APPLICABLE).THE g, PRODUCT STANDARDS LETTER,THIS DEFINITION APPLIES. - - AND DIVISION 1 GENERAL REQUIREMENTS APPLY TO THE WORK OF THIS SECTION.EXAMINE IMPLEMENTED BY THE SECURITY CONTRACTOR,AS NECESSARY.SECURITY CONTRACTOR SHALL ENGINEER RESERVES THE RIGHTTO APPROVE THE CONTRAC DR'S PROJECT MANAGER. 1. WITHIN THE TECHNICAL SPECIFICATIONS FOR THE SECURITY SYSTEM,CERTAIN H. "CORE"•THE ENTRANCE TO THE DATA CENTER FOR BOTH PUBLIC AND PRIVATE NETWORK SERVICE REFERENCED DOCUMENTS FOR REQUIREMENTS AFFECTING THE WORK. PROVIDE RELAY INTERFACE TO THE FIRE ALARM TIE-IN FROM ITS LOCK POWER SUPPLY. 6. BY SUBMITTING A BID,THE SECURITY CONTRACTOR THEREBY CERTIFIES THAT IT IS QUALIFIED MANUFACTURERS HAVE BEEN SPECIFIED.THESE MANUFACTURERS ARE LISTED FOR EXAMPLE CABLES INCLUDING THE POINT OF ENTRY FROM THE PUC ROOMS THE BASE BUILDING AND B. DRAWINGS,GENERAL CONDITIONS OF THE CONTRACT ANO DIVISION 1 GENERAL REQUIREMENTS 9• THE SECURITY CONTRACTOR MUST PROVIDE APPROPRIATE FIRE STOP PROVISIONS FOR ALL IN ALL AREAS PERTAINING TO,EITHER DIRECTLY OR INDIRECTLY,THE WORK.IN THE EVENT THE PURPOSES ONLY(UNLESS FOLLOWED BY"NO EXCEPTIONS").THE CONTRACTOR IS CONTINUING TO THE DATA CENTER PODS. APPLY TO THE WORK OF THIS SECTION.EXAMINE REFERENCED DOCUMENTS FOR REQUIREMENTS CABLES THAT PASS THROUGH FIRE-RATED WALLS,FLOORS,RISERS AND CEILINGS. HOWEVER, SECURITY CONTRACTOR BECOMES UNABLE TO COMPLETE THE WORK IN ACCORDANCE WITH ENCOURAGED TO SUBSTITUTE MANUFACTURERS AND MODELS THAT MAY BE MORE COST I. "CPU": CENTRAL PROCESSING UNIT. AFFECTING THE WORK. EXA !NEA THEA E ION F THE PE IFICATI NS AND ALL OTHER DRAWINGS FOR THIS DOES NOT INCLUDE PROVISIONS ALREADY ESTABLISHED AS PART OF THE MAIN THE CONTRACT DOCUMENTS,OR THE SATISFACTION OF THE OWNER OR ITS REPRESENTATIVES, EFFECTIVE OR READILY AVAILABLE THAN THAT SPECIFIED.ALL SUBSTITUTIONS SHALL MELT OR J. "CREDENTIAL": DATA ASSIGNED TO AN ENTITY AND USED TO IDENTIFY THAT ENTITY. C. M Ll O SCT S O S C O CONTRACTOR OR ELECTRICAL CONTRACTOR'S SCOPE OF WORK. DUE TO A LACK OF UNDERSTANDING OF EQUIPMENT,SYSTEMS OR SERVICES REQUIRED BY THE EXCEED THE MINIMUM FUNCTIONAL AND TECHNICAL SPECIFICATIONS.ACCEPTANCE OF SUCH K. "DEMARCATION POINT":A POINT AT WHICH TWO SERVICES MAY INTERFACE AND IDENTIFY THE RPQ IFICA LY M NTION D IN T WORK UNDER THIS SECTION,WHETHER OR NOT SUCH WORK i5 CONTRACT DOCUMENTS,IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RETAIN SUBSTITUTIONS IS ATTHE DISCRETION OF THE ENGINEER. DIVISION OF RESPONSIBILITY. IT IS A POINT WHERE OPERATIONAL CONTROL OR OWNERSHIP SPECIFICALLY MENTIONED IN THIS SECTION. 10. THE SECURITY CONTRACTOR SHALL PROVIDE ANY AND ALL SLEEVE OR CONDUIT PATHWAYS CHANGES. AN EXAMPLE WOULD BE THE INTERFACE BETWEEN A PUBLIC NETWORK ANDA PRIVATE 1.02 SUMMARY DESCRIPTION REQUIRED THAT ARE NOT ALREADY PROVIDED BY ELECTRICIAN{MEANING ON THE ELECTRICAL THE SERVICES OF THE APPLICABLE MANUFACTURERS'REPRESENTATIVES TO EXPEDITIOUSLY 2, PROVIDE ATTHE TIME OF INSTALLATION THE LATEST VERSION OF ALL EQUIPMENT ANO NETWORK. COMPLETE THE WORK IN ACCORDANCE WITH THE ENGINEER'S CONSTRUCTION SCHEDULE A. CVS HEALTH-CORAM,HEREAFTER REFERRED TO AS THE"OWNER",IS BUILDING OUTA NEGATIVE DRAWINGS,WHICH,BY REFERENCE,INCLUDE THE INFRASTRUCTURE AS SHOWN ON THE WITH NO ADDITIONAL COSTTOTHE OWNER. SOFTWARE,UNLESS OTHERWISE SPECIFIED.DISCONTINUED EQUIPMENT SHALL NOT BE L. "ENTRANCE POINT":THE POINT OF EMERGENCE OF LOW VOLTAGE CONDUCTORS THROUGH AN PRESSURE ROOM IN A LEASED FACILITY AT 7358 SW DURHAM RD.,PORTLAND,OR 97224. THIS SECURITY DRAWINGS). IN OTHER WORDS,THE CONTRACTOR SHALL NOT PENETRATE ANY ACCEPTABLE. EXTERIOR WALL,A CONCRETE FLOOR SLAB,OR FROM A RIGID METAL CONDUIT OR INTERMEDIATE SPECIFICATION CONTAINS THE REQUIREMENTS FOR THE INSTALLATION OF AN INTEGRATED SHEET ROCK WALLS AND PULL CABLE THROUGH HOLES IN THE SHEETROCK. B. PERFORMANCE AND PAYMENT BOND METAL CONDUIT. 3. ALL EQUIPMENT SHALL BE NEW,UNUSED,UNMODIFIED(OFF THE SHELF)EQUIPMENT AS ` PHYSICAL SECURITY SYSTEM. AlL QUOTATIONS MUST ENSURE THATANY INABILITY TO COMPLY 1. REFER TO CONSTRUCTION MANAGER'S REQUIREMENTS M. "EQUIVALENT","SIMILAR",OR"EQUAL"-OF BASE BID MANUFACTURER,EQUAL IN MATERIALS, ST Mi/t WITH THESE REQUIREMENTS IS CLEARLY STATED IN THE QUOTATION SUBMISSION. D. NOT IN CONTRACT WORK: SPECIFIED HEREIN.THE EXACT STYLE,COLOR,FINISH AND MOUNTING TECHNIQUE SHALL BE SIZE,COLOR,DESIGN,AND EFFICIENCY OF SPECIFIED PRODUCT,CONFORMING TO THE SPECIFIED �1 B. THE FACILITY IS TRANSITIONING TO A LENEL BASED CORPORATE ENTERPRISE SECURITY 1. CERTAIN ITEMS NECESSARY FOR A COMPLETE AND OPERATIONAL SECURITY SYSTEM SHALL NOT C. INSURANCE APPROVED BY THE OWNER PRIOR TO INSTALLATION. BASE BID MANUFACTURER. NOTE:MUST BE APPROVED BY WB ENGINEERING,INC.PRIOR TO BID � g MANAGEMENT SYSTEM AND GRADUALLY PHASING OUT AND CUTTING OVER THE EXISTING BE PROVIDED BY SECURITY CONTRACTOR. HOWEVER,SECURITY CONTRACTOR IS RESPONSIBLE 1. REFER TO CONSTRUCTION MANAGER'S REQUIREMENTS ACCEPTANCE. THE PROPOSED SUBSTITUTION MUST,IN EVERY TECHNICAL SENSE,PROVIDE THE CORAM, INC. C. ALL HARDWARE,SOFTWARE,AND FIRMWARE PROVIDED AS PART OF THE WORK SHALL SUPPORT 2 SYSTEM TO NEW PHYSICAL SECURITY STANDARDS FOR SECURITY DEVICES AND SOFTWARE. THIS FOR COORDINATING WITH THE GENERAL CONTRACTOR,ARCHITECT,AND SUB-CONTRACTORS SAME OR BETTER CAPABILITY AND FUNCTIONALITY AS THE SPECIFIED ITEM. SUCH REQUESTS FOR 7358 S W DURHAM RD. 1.09 INSTRUCTION TO BIDDERS A FOUR DIGIT YEAR DESCRIPTION AND SHALL BE OESIGNEDTO REMAIN OPERATIONAL ON OR INSTALLATION WILL INVOLVE MAINTAINING IN PLACE AND OPERABLE EXISTING SECURITY DEVICES (OR OTHER PARTIES)FOR ALL NIC MATERIALS THAT ARE RELATED TO THE SECURITY SYSTEMS AFTER JANUARY 1,2020 AD. APPROVAL SHALL BE SUBMITTED IN ACCORDANCE WITH THE PROVISIONS OF THIS SPECIFICATION (E.G.,READERS,CAMERAS,PANELS,ETC...)NOT DIRECTLY AFFECTED BY THE RENOVATION, INSTALLATION. THESE NIC ITEMS MAY INCLUDE,BUT ARE NOT LIMITEDTO: A. RECEIPT 1.17 TERMS AND CONDITIONS AND MUST BE OBTAINED WITHIN THE TIME FRAMES OUTLINED. ' PORTLAND, OR 97224 RE-CABLING AND/OR UPGRADING PHYSICAL SECURITY DEVICES WITHIN THE AFFECTED AREA AND 1. REFER TO CONSTRUCTION MANAGER'S REQUIREMENTS. N. "EXPOSED":MEANS NOT INSTALLED UNDERGROUND OR"CONCEALED"AS DEFINED ABOVE. INSTALLING NEW PHYSICAL SECURITY DEVICES AND NEW HEAD-END EQUIPMENT AS SPECIFIED A ALL HIGH VOLTAGE POWER AND ELECTRICAL OUTLETS A. ALL BIDS MUST BE SUBMITTED IN ACCORDANCE WITH THE SPECIFICATIONS AND INFORMATION 0. "GFI": GROUND FAULT INTERRUPTER. f ROI" 1 �' PHARMACY HEREIN WHICH WILL BE LOCATED IN THE IDT WHERE INDICATED ON PLANS AND WILL BE B. DUE DATE CONTAINED HEREIN,AS WELL AS WITH SUPPLEMENTAL REQUIREMENTS AND ANY ADDENDA P. "I/O": INPUT/OUTPUT. SEAMLESSLY INTEGRATED WITHIN THE FACILITY AND CONNECTED TO CORPORATE NETWORK. B ALL SLEEVES ANO CONDUITS AS RELATED TO THE SECURITY RISER 1. REFER TO CONSTRUCTION MANAGER'S REQUIREMENTS. ISSUED BY THE CONSTRUCTION MANAGER. C ALL PLYWOOD BACKBOARDS(SECURITY WALL FIELDS) Q. "IDENTIFIER": A CREDENTIAL CARD,KEYPAD PERSONAL IDENTIFICATION NUMBER OR CODE, C. THE CLIENT HEREBY INVITES YOU(HEREAFTER REFERRED TO AS THE"BIDDER"OR"SECURITY C. RETURN OF PROPOSAL B. CLIENT,THE CONSTRUCTION MANAGER,AND WB ENGINEERS)CONSULTANTS WILL NOT BE BIOMETRIC CHARACTERISTIC,OR OTHER UNIQUE IDENTIFICATION ENTERED AS DATA INTO THE CONTRACTOR")TO SUBMIT A PROPOSAL TO FURNISH AND INSTALLTHE WORK SPECIFIED IN THIS D ALL HOLES FOR RECESSED DOOR CONTACTS TH DDE E T B 1D RESPONSIBLE FOR ANY EXPENSE INCURRED BY THE BIDDER MADE IN CONNECTION WITH ENTRY-CONTROL DATABASE FOR THE PURPOSE OF IDENTIFYING AN INDIVIDUAL. WHERE THIS 1. E BI R WHO LECTS NO TO SU MIT A 8 SHALL RETURN ALL MATERIALS INTACT. PROSECT NUS DOCUMENT AND RELATED MATERIALS. PRIOR TO SUBMITTING A PROPOSAL,THE BIDDER SHOULD E ALL HORIZONTAL CONDUITS,lUNCTiON BOXES,BACK BOXES AND CONDUIT STUB-UPS. REVIEWING OR RESPONDING TO THIS DOCUMENT,OR INCURRED AT ANY TIME DURING THE TERM IS PRESENTED WITH AN INITIAL CAPITAL LETTER,THIS DEFINITION APPLIES. 1 O�O6369 CONSIDER THE SCOPE OF WORK,THE QA/QC REQUIREMENTS,THE TIME FRAME,AND THE F ALL STRUCTURAL WORK,WALL OPENINGS,PLATFORMS,RAILINGS,STAIRS,FIRE D. RESPONSE INSTRUCTIONS PROPOSAL REVIEW AND AWARD PROCESS. ANY AND ALL SUCH EXPENSES SHALL BE THE BIDDER'S R. "IDT": INTERMEDIATE DISTRIBUTION FRAME I.E.,TELECOMMUNICATIONS ROOM •., COMMITMENT OF RESOURCES REQUIRED TO RESPOND IN A PROFESSIONAL MANNER. PREVENTION AND SAFETY DEVICES,ROUGH AND FINISHED TRIM,PAINTING AND SOLE RESPONSIBILITY. ( ) 1. RESPONSES WILL FOLLOW INSTRUCTIONS PROVIDED BY CONSTRUCTION MANAGER. S. "INDICATED","SHOWN",OR"NOTED': AS INDICATED,SHOWN,OR AS NOTED ON DRAWINGS OR D. THE SYSTEMS PROPOSED BY THE BIDDER MUST MEET ALL OF THE SPECIFICATIONS DESCRIBED PATCHING,CARPETS,FLOOR COVERINGS,COMPUTER FLOORS,AND HEATING, C. THE PRODUCTS SPECIFIED IN THIS DOCUMENT ARE TO BE USED EXCLUSIVELY. NO SUBSTITUTIONS SPECIFICATIONS. HEREIN.EACH COMPONENT IN THE PROPOSED SYSTEM SHALL BE CONSIDERED FOR ITS VENTILATING,AND AIR CONDITIONING SYSTEMS. 2. ALL HARD COPY AND ELECTRONIC PRICING FORMS REQUIRED BY THIS SPECIFICATION MUST BE OF COMPONENTS SPECIFICALLY REFERENCED WILL BE ALLOWED,WITHOUT PRIOR WRITTEN INDIVIDUAL MERITS AND FOR ITS CONTRIBUTION TO THE ENTIRE SYSTEM. THE BIDDER MUST G ALL TELEPHONE AND OTHER COMMUNICATIONS SYSTEMS WIRING PERTAINING TO FULLY COMPLETED,EVEN IF REDUNDANT TO CONSTRUCTION MANAGER FORMS. CONSENT FROM CLIENT OR WB ENGINEERS)CONSULTANTS AFTER SUBMITTAL REVIEW. T. "INSTALL": IS USED TO DESCRIBE OPERATIONS AT PROJECT SITE(AND/OR MOVE FROM PROPERTY INCLUDE SPECIFICATION SHEETS,AND OTHER LITERATURE AND DOCUMENTS TO SUPPORTTHE SECURITY SYSTEMS. COORDINATE WITH THE TELECOMMUNICATIONS CONTRACTOR AND 0. THE BIDDER SHALL VISIT THE SITE OF THE PROPOSED WORK TO IDENTIFY ANY EXISTING LINE)INCLUDING THE ACTUAL UNLOADING,UNPACKING,RIGGING IN PLACE,ASSEMBLY, ARCHITECT OF RECORD 3. DESIGN DRAWINGS FOR THE PROJECT ACCOMPANY THIS BID SPECIFICATION. THE BID ERECTION,PLACING,ANCHORING,APPLYING,WORKING TO DIMENSION,FINISHING,CURING, EQUIPMENT CHOICES IN THE BID PROPOSAL. THE BIDDER SHALL ACKNOWLEDGE THAT UNLESS THE OWNER TO IMPLEMENT THE VARIOUS TELEPHONE LINES FOR THE SECURITY SYSTEM CONDITIONS THAT MAY AFFECT THE WORK,TO REVIEW THE DRAWINGS OF OTHER TRADES,AND OTHERWISE INDICATED HEREIN THERE SHALL BE NO SUBSTITUTES FOR ANY EQUIPMENT OR (IF APPLICABLE). SPECIFICATION DOCUMENT IS AN ALL-ENCOMPASSING DOCUMENT WITH TECHNICAL TO BECOME FAMILIAR WITH THE SITE IN GENERAL PRIOR TO SUBMITTING ITS PROPOSAL AND PROTECTING,CLEANING,AND SIMILAR OPERATIONS. IT MEANS THE INSTALLATION IS TO BE SPECIFICATIONS AND PRICING REQUIREMENTS ADDRESSING TERMS,CONDITIONS, COMPLETE AND READY FOR REGULAR OPERATION,EXCEPT AS OTHERWISE NOTED. MATERIALS SPECIFIED. H DOOR HARDWARE IS BY OTHERS UNLESS OTHERWISE SPECIFIED. SHALL BE HELD RESPONSIBLE FOR ANY ASSUMPTIONS MADE IN THAT REGARD. E. THE PHYSICAL SECURITY SYSTEMS PROJECT SHALL INCLUDE SCOPE-OF-WORK REQUIREMENTS FOR INSTALLATION,AND TESTING REQUIREMENTS. U. "INSTALLER": AN"INSTALLER"IS THE CONTRACTOR OR AN ENTITY ENGAGED BY THE E. RELATED WORK SPECIFIED ELSEWHERE: E. THE BIDDER SHALL VERIFY ALL DIMENSIONS IN THE FIELD,CONFIRM THE LOCATIONS,DOCUMENT CONTRACTOR,EITHER AS AN EMPLOYEE,SECURITY CONTRACTOR,OR SUB-SECURITY CONTRACTOR - THE GENERAL CONTRACTOR,ELECTRICAL CONTRACTOR,FIRE SAFETY SYSTEMS CONTRACTOR, 1. ELECTRICAL POWER AND RACEWAY ARE TO BE PROVIDED AND INSTALLED BY OTHERS,UNLESS 4. THIS DOCUMENT AND THE ASSOCIATED DRAWINGS ARE BASED ON CURRENTLY KNOWN DISTANCES FROM THE CORE DISTRIBUTION RACKS AND THE POD DISTRIBUTION RACKS OR FOR PERFORMANCE OFA PARTICULAR CONSTRUCTION ACTIVITY,INCLUDING INSTALLATION, ENGINEER,OWNER,AND THE SECURITY CONTRACTOR., CONSOLIDATION POINTS,AND VERIFY CONDITION OR PRESENCE OF CONDUITS,PIPING,LIGHTING OTHERWISE INDICATED. NOTE: THIS DOES NOT INCLUDE ELECTRICAL PROVISIONS PROVIDED CONDITIONS AND SITUATIONS. ANOMALIES MAY EXIST OF WHICH CLIENT AND WB ENGINEERS ERECTION,APPLICATION,AND SIMILAR OPERATIONS. INSTALLERS ARE REQUIRED TO BE F. THE ACCESS CONTROL SYSTEM IS COMPRISED OF CARD READERS,LOCKING HARDWARE AND AND DEVICES INSTALLED. AND INSTALLED BY SECURITY CONTRACTOR TO PROTECT THE INTERCONNECT CABLES FOR THE (CONSULTANTS ARE NOT AWARE. EXPERIENCED IN THE OPERATIONS THEY ARE ENGAGED TO PERFORM. ALARM SENSORS THAT SHALL MONITOR ENTRY DOORS,STAIRWELLS,COMMUNICATION ROOMS, F. THE BIDDER SHALL COMPLY WITH ALL APPLICABLE GOVERNMENTAL REGULATIONS AND WITH ALL SECURITY HARDWARE INSTALLED IN THE COMM.ROOM• V. "IPS": IMAGES PER SECOND. AND OTHER CRITICAL AREAS.THE BIDDER WILL PURCHASE ALL NECESSARY ADDITIONAL CARD 5. COMPLIANCE WITH REQUIREMENTS: THE BIDDER SHALL CONFIRM THAT IN ALL RESPECTS THE FEDERAL,STATE,CITY,AND OTHER APPLICABLE CODES AND ORDINANCES. W. "LACE OR WRAP": A TERM USED TO DESCRIBE THE PLACEMENT OF CABLE ON CABLE TRAY, READER SOFTWARE LICENSES TO SUPPLEMENT EXISTING. THE ENTERPRISE LENEL SERVER RESIDES 2. INTEGRAL MILLWORK,SECURITY DESKS,AND SIMILAR PERIPHERALS TO SUPPORT THE BIDDER'S QUOTATION CONFORMS TO ALL SPECIFICATIONS,TERMS AND CONDITIONS 1.18 COMPLIANCE WITH CODES,REGULATIONS,AND STANDARDS "LAC EO RWR P": ACER MANAGEMENT AND HORIZONTAL ENT OF CABLE ON CABLE T A CLEAN ON CVS HEALTH APPLICATION SERVER(S)ON THE CVS HEALTH CORPORATE NETWORK AND IS EQUIPMENT INSTALLATION,PROVIDED AND INSTALLED BY OTHERS. INCORPORATED AND MADE A PART OF THIS BID PACKAGE. FLOW R ACK,V RTOM PAANH GENEL T ND HORI ONT UNITED TRE WOTK ENSURE A CLE MAINTAINED AND SUPPORTED BY OTHERS;OUTSIDE THE SCOPE OF THIS CONTRACT. A. ALL INSTALLATIONS AND EQUIPMENT SHALL BE IN COMPLIANCE WITH,EQUAL TO OR EXCEED THE G. THE SECURITY CONTRACTOR SHALL BE RESPONSIBLE FOR ATURNKEY INSTALLATION OF 3. NETWORK EQUIPMENT,WHICH SHALL BE PROVIDED BY CLIENT. 6. THE BIDDER WILL ENSURE THAT RESPONSES ARE MADE IN THE SAME ORDER AND USING THE MINIMUM REQUIREMENTS OF OSHA,NEC,NEMA,IEEE,ANSI,UL,EIA/TIA RECOMMENDATIONS X. "LAN": LOCAL AREA NETWORK. ADDITIONAL DEVICES FOR THE ACCESS CONTROL AND ALARM MONITORING SYSTEM(ACAM)AND SAME NUMBERING CONVENTIONS AS USED IN THIS SPECIFICATION IN ORDER TO FACILITATE AND THE RULES,REGULATIONS AND REQUIREMENTS OF THE FEDERAL COMMUNICATIONS Y. "LED": LIGHT-EMITTING DIODE. F. DELIVERY,STORAGE AND HANDLING COMMISSION. THE VIDEO SECURITY SYSTEM AND ALL RELATED COMPONENTS ASA LUMP SUM CONTRACT. THE EVALUATION PROCESS. PROPOSALS THAT DO NOT INCLUDE ALL REQUESTED MATERIALS Z. "LOCATION": A LOCATION ON THE NETWORK HAVING A PC TO-CONTROLLER COMMUNICATIONS 1. COSTS OF ALL SHIPPING TO THE SITE,AND OF ALL UNUSUAL STORAGE REQUIREMENTS,SHALL B. THE INSTALLATION SHALL COMPLY FULLY WITH ALL APPLICABLE COUNTY AND STATE LAWS, LINK,WITH ADDITIONAL CONTROLLERS AT THE LOCATION CONNECTED TO THE H. VIDEO SECURITY: BE BORNE BY THE SECURITY CONTRACTOR. IT SHALL BE THE RESPONSIBILITY OF SECURITY SHALL BE CONSIDERED UNRESPONSIVE. ORDINANCES,REGULATIONS,AND CODES. PC-TO-CONTROLLER LINK WITH RS-485 COMMUNICATIONS LOOP. WHERE THIS TERM IS 1. ALL NETWORK IP CAMERAS SHALL BE CABLED FROM THEIR ASSOCIATED MOF PATCH PANELS CONTRACTOR TO MAKE APPROPRIATE ARRANGEMENTS,AND TO COORDINATE WITH 1.10 RIGHT OF REJECTION C. LOCAL ELECTRICAL AND BUILDING CODES MAY BE MORE STRINGENT THAN NATIONAL CODES, PRESENTED WITH AN INITIAL CAPITAL LETTER,THIS DEFINITION APPLIES. LOCATION(DEFINED UNDER A SEPARATE CONTRACT-SEE THE INFORMATION TECHNOLOGIES AUTHORIZED PERSONNEL AT THE SITE,FOR THE PROPER ACCEPTANCE,HANDLING, RECOMMENDATIONS OR PRACTICE. FOLLOW THE MOST RESTRICTIVE CODE OR AA. "MDF": MAIN DISTRIBUTION FRAME(I.E.,MAIN TELECOMMUNICATIONS ROOM) DRAWINGS FOR REFERENCE)TO A WALL OR CEILING MOUNTED BISCUIT BY OTHERS. THE A. CLIENT AND CONSTRUCTION MANAGER RESERVE THE RIGHT TO ACCEPT OR REJECT ANY OR ALL PROTECTION,AND STORAGE OF EQUIPMENT SO DELIVERED. RECOMMENDATIONS BB. "NO SUBSTITUTES": THE EXACT MAKE AND MODEL NUMBER IDENTIFIED IN THIS SPECIFICATION NETWORK CHANNEL FOR VIDEO SECURITY WILL BE INSTALLED AND TESTED BY OTHERS AND BIDS AND TO ENTER INTO DISCUSSION AND/OR NEGOTIATIONS WITH ANY OR MORE THAN ONE D. SHOULD ANY CHANGE IN PLANS OR SPECIFICATIONS BE REQUIRED TO COMPLY WITH SHALL BE PROVIDED WITHOUT EXCEPTION. WILL MEET OR EXCEED ALL PERFORMANCE REQUIREMENTS FOR CATEGORY 6 UTP IN 2. MOVEMENT OF MATERIAL EITHER ATTHE TIME OF DELIVERY OR SUBSEQUENTLY SHALL BE THE QUALIFIED SUPPLIER ATTHE SAME TIME OR ANY TIME,SHOULD SUCH ACTION BE IN THE BEST ACCORDANCE WITH THE REQUIREMENTS SPECIFIED IN DIVISION 16700. SOLE RESPONSIBILITY OF SECURITY CONTRACTOR AS SHALL ALL COSTS ASSOCIATED WITH THIS INTERESTS OF CLIENT. GOVERNMENTAL REGULATIONS OR INDUSTRY STANDARDS,THE SECURITY CONTRACTOR SHALL CC. "PBX": PRIVATE BRANCH EXCHANGE(TELEPHONE EQUIPMENT ROOM) MOVEMENT. B. NEITHER THE CONSTRUCTION MANAGER NOR CLIENT IS UNDER ANY OBLIGATION TO AWARD A NOTIFY THE CONSTRUCTION MANAGER A7 THE TIME OF BID SUBMISSION. DD. "PC": PERSONAL COMPUTER. THIS ACRONYM APPLIES TO THE CENTRAL STATION, CONSULTANT• I 2. ALL FIXED CAMERAS(INTERIOR AND EXTERIOR)SHALL BE COLOR,IP SURVEILLANCE,WITH CONTRACT ON THE BASIS OF THIS BID. 1.14 REFERENCE CODES AND STANDARDS WORKSTATIONS,AND FILE SERVERS. MPEG-4 COMPRESSION;UNLESS OTHERWISE SPECIFIED HEREIN. G. PROJECT CONDITIONS: 1.11 RIGHT OF INCORPORATION A. THE FOLLOWING CODES AND STANDARDS APPLY: EE. "PCI BUS": PERIPHERAL COMPONENT INTERCONNECT;A PERIPHERAL BUS PROVIDING A 1. CONTRACTOR SHALL STRIVE FOR LABOR HARMONY. 1. AMERICAN NATIONAL STANDARDS INSTITUTE(ANSI} HIGH-SPEED DATA PATH BETWEEN THE CPU AND PERIPHERAL DEVICES(SUCH AS MONITOR,DISK I. THE SECURITY CONTRACTOR IS RESPONSIBLE FOR PROVIDING,INSTALLING AND TERMINATING ALL A. IT IS UNDERSTOOD THAT BIDDER'S RESPONSE DOES NOT CONSTITUTE AN OFFER ON THE TERMS DRIVE,OR NETWORK). SECURITY NETWORK DEVICES(E.G.,IP CAMERAS,OR OTHER APPROVED NETWORK-READY DEVICES) 2. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF HIS WORK FROM ACTS OF STATED IN THE PROPOSAL,AND THAT SHOULD A CONTRACT BE AWARDED,CLIENT AND THE 2. AMERICANS WITH DISABILITIES ACT(ADA) FF. "PDF": PORTABLE DOCUMENT FORMAT. THE FILE FORMAT USED BY THE ACROBAT DOCUMENT AND CABLING FROM THE NETWORK ACCESS POINT TO THE DEVICE;UNLESS OTHERWISE NOTED. VANDALISM AND ENVIRONMENTAL CONDITIONS. CONSTRUCTION MANAGER MAY,AT THEIR OPTION,INCORPORATE ALL OR ANY PART OF YOUR ( ) EXCHANGE SYSTEM SOFTWARE FROM ADOBE. , PATCH CORDS MUST MATCH THE MANUFACTURER OF THE APPROVED STRUCTURED CABLING 3. CONTRACTOR SHALL CLEAN UP AND REPAIR ALL AREAS AFFECTED BY HIS INSTALLATION. RESPONSE W THE CONTRACT. 3. BUILDING OFFICIALS AND CODE ADMINISTRATORS,INTERNATIONAL{SOCA}THE BOLA GG. "POD":GROUP OF RACKS OR CABINETS WITHIN THE DATA CENTER,USUALLY CONSISTING OF 2 �_ Eng I n eers+ SYSTEM-COORDINATE WITH lT CONTRACTOR TO ASSURE ADHERENCE TO PERFORMANCE AND 1.12 CONFIDENTIALITY OF BIDDER INFORMATION NATIONAL BUILDING CODE_i ROWS. 3 Consultants WARRANTY REQUIREMENTS. 4. CONTRACTOR MUST ATTEND ALL JOB MEETINGS,UNLESS TOLD OTHERWISE BY THE OWNER'S _ J. ALl IP NETWORK DATA CASIlNG,TERMINATION,TESTING AND ASSOCIATED NETWORK REPRESENTATIVE. A. YOU ARE BEING REQUESTED TO PROVIDE TO CLIENT DATA REGARDING YOUR ORGANIZATION AND 4. ELECTRONIC INDUSTRIES ASSOCIATION(EIA) HH. "PROJECT SCHEDULE":MEANS SUBSETS OF THE WORK COMPLYING WITH SPECIFIC SCHEDULE _-�. COMPONENTS ARE FURNISHED AND INSTALLED UNDER A SEPARATE CONTRACT BY THE i7 YOUR PRODUCTS AND SERVICES. TARGETS WITHIN THE SECURITY CONTRACTORS SCHEDULE AS WELL AS THE COLLECTIVE CONTRACTOR. ALL NON-IP PHYSICAL SECURITY CABLING INSTALLATION IS FURNISHED AND 5. CONTRACTOR SHALL DOCUMENT ALL ACTIVITIES PERTAINING TO THE SCHEDULE OF THE B. IN THE EVENT ANY DATA SUPPLIED TO CLIENT IS CONFIDENTIAL,PLEASE NOTE SUCH 5. FEDERAL INFORMATION PROCESSING STANDARDS(FIPS) COMPLETION DATES INDICATED WITHIN THE GENERAL CONTRACTORS SCHEDULE. CONFIDENTIALITY IN A SEPARATE LETTER. II. "PROVIDE": MEANS TO SUPPLY,PURCHASE,TRANSPORT,PLACE,ERECT,CONNECT,LABEL,TEST INSTALLED UNDER A SEPARATE CONTRACT BY THE 17 CONTRACTOR;THE BIDDER SHALL ONLY BE SECURITY SYSTEM IMPLEMENTATION.THIS DOCUMENTATION SHALL BE USED AS A GENERAL 6. INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS(IEEE) RESPONSIBLE FOR DIRECTING AND COORDINATING THE CABLING REQUIREMENTS WITH THE IT STATUS REPORT FOR GENERAL CONSTRUCTION PURPOSES. ALL ISSUES AND CONCERNS SHALL C. CLIENT AGREES THAT FOR A PERIOD OF ONE(1)YEAR IT SHALL TAKE THE SAME STEPS TO PROTECT AND TURN OVER TO THE OWNER A COMPLETE AND READY FOR REGULAR OPERATION,ALL 155 SEAPORT BOULEVARD CONTRACTOR AND THE BIDDER IS RESPONSIBLE FOR CABLE TERMINATION AND TESTING OF BE NOTED IN THESE DOCUMENTS FOR COORDINATION WITH THE APPROPRIATE PARTIES. THE CONFIDENTIALITY OF SUCH INFORMATION,AS IT TAKES IN CONNECTION WITH INFORMATION 7. LOCAL AUTHORITIES HAVING JURISDICTION MATERIALS,LABOR,EQUIPMENT,TESTING APPARATUS,CONTROLS,TESTS,ACCESSORIES AND ALL PHYSICAL SECURITY CABLES AND DEVICES. OBTAIN A COPY OF THE IT DRAWINGS AND ABOUT ITSELF. HOWEVER,IN NO EVENT,SHALL INFORMATION ABOUT YOU OR YOUR PRODUCTS OTHER ITEMS CUSTOMARILY REQUIRED FOR AN ACCESS CONTROL AND ALARM MONITORING SEAPORT WEST, FLOOR 2 ISSUES THAT ARE NOT DOCUMENTED SHALL BE CONSIDERED SOLELY THE RESPONSIBILITY OF 8. MICROSOFT®OPEN DATABASE CONNECTIVITY(ODBC)INTERFACE) SYSTEM(ALSO MEANING TO"FURNISH AND INSTALL"). SPECIFICATIONS TO GAIN A THOROUGH UNDERSTANDING OF CABLING INFRASTRUCTURES BE DEEMED CONFIDENTIAL IF: BOSTON, MA 02210 THE SECURITY CONTRACTOR,AND SHALL NOT BE A FACTOR IN THE OVERALL CONSTRUCTION RELATED TO THE PHYSICAL SECURITY SYSTEM THAT ARE FURNISHED,INSTALLED AND TESTED BY 1. ALREADY KNOWN TO CLIENT,ALREADY IN THE PUBLIC DOMAIN,OR DISCLOSED TO CLIENT BY A 9. NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION(NEMA)STANDARDS JJ. "PROVISION":THE TERM"PROVISION"MEANS TO"FURNISH AND INSTALL COMPLETE AND READY P.617.443.4950• F.617.443.4959 OTHERS. ALL QUOTATIONS MUST ENSURE THAT ANY INABILITY TO COMPLY WITH THESE SCHEDULE. THIRD PARTY HAVING A RIGHT TO MAKE SUCH DISCLOSURE. FOR THE INTENDED USE". REQUIREMENTS IS CLEARLY STATED IN THE QUOTATION SUBMISSION. 1.06 SCOPE OF WORK 10. NATIONAL FIRE PROTECTION ASSOCIATION(NFPA 70) KK. "PUC ROOM"(PUBLIC UTILITY CLOSET):THE LOCATION WITHIN THE CUSTOMER PREMISES THAT IS K. THE PHYSICAL SECURITY SYSTEMS SHALL BE INTEGRATED WITH CVS CORPORATE NETWORK 2. IN NO EVENT,WITHOUT THE PRIOR WRITTEN CONSENT OF CLIENT,SHOULD YOU REVEAL TO THE ENTRANCE TO A BUILDING(A.K.A.ENTRANCE FACILITY)FOR BOTH PUBLIC AND PRIVATE POLICIES. ALL SWITCHES,IP ASSIGNMENTS,SUBNETS,VLANS,AND CORPORATE NETWORK A. THIS QUOTATION IS TO INCLUDE THE ADDITION OF INTRUSION DLI ECTION,ACCESS CONTROL, CLIENT ANY DATA THAT YOU DEEM A TRADE SECRET,BECAUSE CLIENT'S OBLIGATION OF 11. NATIONAL FIRE PROTECTION ASSOCIATION LIFE SAFETY CODE NETWORK SERVICE CABLES(INCLUDING ANTENNAE}INCLUDING THE POINT OF ENTRY ATTHE CONNECTIVITY IS FURNISHED AND SUPPLIED BY OWNER AND COORDINATED WITH THE AND VIDEO SECURITY DEVICES INCLUDING ALL NECESSARY HARDWARE;INSTALLATION OF ALL CONFIDENTIALITY AS SET OUT IN THIS PARAGRAPH MAY NOT BE SUFFICIENT TO PROTECT THE 12. NATIONAL ELECTRICAL SAFETY CODE(NESC)IEEE C2 BUILDING WALL AND CONTINUING TO THE ENTRANCE ROOM OR SPACE. IT IS GENERALLY THE DESIGN/CONSTRUCTION TEAM AS DESCRIBED HEREIN. HARDWARE;ALL NECESSARY SOFTWARE LICENSING;TESTING AND COMMISSIONING OF THE SAME. LOCATION OF THE(INTERFACE)DEMARCATION POINT BETWEEN THE SERVICE PROVIDER'S '- DEVELOPER• L. CONDUITS,ELECTRICAL POWER AND JUNCTION BOXES SHALL BE PROVIDED AND INSTALLED BY SYSTEM AS SPECIFIED INCLUDING ALL WIRING AND EQUIPMENT. FIRE PROTECTION ALARM 13. NEPA,NATIONAL FIRE CODES(NEC} CIRCUITS AND THE CUSTOMER'S EQUIPMENT AND/flR PRIVATE NETWORK COMPONENTS. OTHERS.THIS SHALL INCLUDE HIGH VOLTAGE POWER,RISER CONDUITS,JUNCTION BOXES AND INTERFACES SHALL BE IN ACCORDANCE WITH ALL APPLICABLE REGULATIONS. D. THE PHYSICAL PROTECTION SYSTEM AND WORK DEFINED HEREIN IS CRITICALTO THE SECURITY OF LL. "REVIEWED","SATISFACTORY","ACCEPTED","APPROVED",OR"DIRECTED"-AS REVIEWED, ° . CONDUIT STUB-UPS FOR INDIVIDUAL DEVICES. THE SECURITY CONTRACTOR IS RESPONSIBLE FOR 8. PREPARE AND PRESENT PRODUCT SUBMITTALS(INCLUDE IN PROPOSAL)AS SPECIFIED. THE CLIENTS/OWNERS FACILITY. ALL PLANS,SPECIFICATIONS AND OTHER DOCUMENTARY 14. TELECOMMUNICATIONS INDUSTRIES ASSOCIATION(TIA) SATISFACTORY,ACCEPTED,APPROVED,OR DIRECTED BY THE ARCHITECT,ENGINEER AND OWNER. a PRO-ACTIVELY COORDINATING POWER REQUIREMENTS WITH THE GENERAL CONTRACTOR AND C. THE PHYSICAL PROTECTION PROJECT SHALL INCLUDE SCOPE-OF-WORK REQUIREMENTS FOR THE MATERIAL AND INFORMATION ABOUT THE WORK ARE CONFIDENTIAL INFORMATION AND MUST S5. UNIFORM BUILDING CODE(UBC) MM. "RF": RADIO FREQUENCY. y RELATED SUB-CONSULTANTS IN ACCORDANCE WITH THE GENERAL CONTRACTORS AND GENERAL CONTRACTOR,ELECTRICAL CONTRACTOR,FIRE SAFETY SYSTEMS CONTRACTOR,THE REMAIN SECURE AND CONFIDENTIAL AT ALL TIMES. CONFIDENTIAL INFORMATION MUST NOT BE CONSTRUCTION MANAGERS COMMUNICATION AND COORDINATION PROTOCOLS FOR THIS OWNER/CLIENT,AND THE SECURITY CONTRACTOR.THE GENERAL CONTRACTOR AND/OR DELIBERATELY OR INADVERTENTLY DISCLOSED TO ANYONE OTHER THAN THE CONTRACTOR'S 16. UNIFORM FEDERAL ACCESSIBILITY STANDARDS(UFAS) NN. "ROM": READ-ONLY MEMORY. ROM DATA ARE MAINTAINED THROUGH LOSSES OF POWER. PROJECT. ELECTRICAL CONTRACTOR SHALL PROVIDE HIGH VOLTAGE POWER, RISER SLEEVES,CONDUIT PERSONNEL AND SECURITY CONTRACTORS WHO REQUIRE DISCLOSURE TO PERFORM THEIR 00. "RS-232": AN TIA/EIA STANDARD FOR ASYNCHRONOUS SERIAL DATA COMMUNICATIONS 1.03 BASIS OF DESIGN AND INTENT OF DRAWINGS STUB-UPS,JUNCTION BOXES,AND DOORS PREPPED FOR SECURITY DEVICES. PORTION OF THE WORK. 17. UNDERWRITERS LABORATORIES(UL)APPLICABLE STANDARDS FOR SAFETY BETWEEN TERMINAL DEVICES. THIS STANDARD DEFINES A 25-PIN CONNECTOR AND CERTAIN D. THE SECURITY CONTRACTOR SHALL BE RESPONSIBLE FOR PROVISION AND INSTALLATION OF ALL E. THE CONTRACTOR SHALL KEEP TRACK OF ALL CONFIDENTIAL INFORMATION AT ALL TIMES AND 18. UNDERWRITERS LABORATORIES(UL),ACCESS CONTROL SYSTEM UNITS(UL 294) SIGNAL CHARACTERISTICS FOR INTERFACING COMPUTER EQUIPMENT. A. ITIS THE INTENT OF THE DRAWINGS AND SPECIFICATIONS TO PROVIDE A COMPLETE WORKABLE SECURITY RELATED FIELD DEVICES,CABLES AND EQUIPMENT{PANELS,CAMERAS,POWER SHALL ENSURE THAT ALL COPIES ARE ACCOUNTED FOR AT ALL TIMES.THE CONTRACTOR SHALL PP. "RS-485": AN TIA/EIA STANDARD FOR MULTIPOINT COMMUNICATIONS. PHYSICAL SECURITY SYSTEM READY FOR THE CLIENTS USE. ANY ITEM NOT SPECIFICALLY SHOWN NOT PERMIT ANY PERSONS TO HAVE ACCESS TO THE CONFIDENTIAL INFORMATION OF THE WORK A SUPPLIES,BURGLAR ALARM INTERFACES,ETC...)FOR THE SECURITY SYSTEM,TERMINATION AND 19. UNDERWRITERS LABORATORIES(UL),ANTI-THEFT ALARMS AND DEVICES(UL 1037) QQ. "SECURITY MANAGEMENT SYSTEM": THE SECURITY MANAGEMENT SYSTEM IS THE KEY CENTRAL ON THE DRAWINGS OR CALLED FOR IN THE SPECIFICATION,BUT NORMALLY REQUIRED FOR UNLESS AND UNTIL THE CONTRACTOR HAS ASSURED ITSELF OF THE TRUSTWORTHINESS OF SUCH COMPONENT FOR MANAGING PHYSICAL SECURITY AND THE BRIDGE BETWEEN PHYSICAL AND TESTING,COORDINATION ISSUES WITH OTHER CONTRACTORS,AND PROGRAMMING THE SYSTEMS ( ) LOGICAL SECURITY FOR THIS PROJECT.THE SYSTEM SHALL PROVIDE A VARIETY OF INTEGRAL COMPLETE SYSTEM,IS TO BE CONSIDERED A PART OF THE CONTRACT. AND SHAH REPORT ISSUES TO THE CONSULTANT WHEN CLARIFICATION IS REQUIRED. PERSONS. 20. UNDERWRITERS LABORATORIES UL,APPLICABLE STANDARDS FOR PROPRIETARY SECURITY B. THE LOCATIONS OF STRUCTURAL AND ARCHITECTURAL FEATURES,EXISTING SLEEVES,FLOOR E. SECURITY CONTRACTOR SHALL COORDINATE WITH THE GCjNPR ROOM MANUFACTURER AND 1.13 USE OF CLIENT'S NAME SYSTEMS FUNCTIONS INCLUDING THE ABILITY TO REGULATE ACCESS AND EGRESS;PROVIDE IDENTIFICATION SLOTS,TERMINATIONS AND CROSS CONNECTS,PANELS,RACKS,CABINETS,GROUND BUSES,AND CREDENTIALS;MONITOR,TRACK AND INTERFACE ALARMS;AND VIEW,RECORD AND STORE ,- OTHER EQUIPMENT INDICATED ON THE DRAWINGS ARE APPROXIMATE. THE SUBCONTRACTOR ELECTRICIAN TO INSTALL AND INTEGRATE THE DOOR INTERLOCK POWER SUPPLY WITH THE DOOR A. IN CONNECTION WITH THIS PROJECT THE BIDDER SHALL NOT USE THE NAME OF CLIENT,OR ANY 21. UNDERWRITERS LABORATORIES(UL),PROPRIETARY BURGLAR ALARM UNITS AND SYSTEMS(UL DIGITAL SURVEILLANCE VIDEO LINKED TO SMS EVENTS. RELEASE BUTTONS AND INTRUSION SYSTEM PANEL.102V POWER SHALL BE INSTALLED BY THE OF ITS SUBSIDIARIES OR AFFILIATES,IN ANY PUBLICATIONS OR PUBLIC RELATIONS " SHALL VERIFY THE EXISTENCE,LOCATIONS,AND SUITABILITY OF ALL SUCH ITEMS,AND SHALL 1076) ELECTRICIAN.CABLING TO/FROM THE DOOR INTERLOCK POWER SUPPLY SHALL BE RUN AND ANNOUNCEMENTS WITHOUT THE WRITTEN CONSENT OF CLIENT,PRIOR TO SUCH PUBLICATION RR. SERVER . A PC IN A NETWORK THAT STORES THE PROGRAMS AND DATA FILES SHARED BY USERS. PRESENT,WITH BID RESPONSE,REQUIRED MODIFICATIONSTO CONTRACT DOCUMENTS TERMINATED BY THE SECURITY CONTRACTOR. OR ANNOUNCEMENT. 22. UNDERWRITERS LABORATORIES(UL),VAULT ALARM SYSTEMS(UL 609) SS. "SHALL"AND"WILL"ARE MANDATORY. C� , NECESSARY TO COMPLETE THIS WORK. TT. "SHOULD"IS ADVISORY. VEAL• 1.04 COORDINATION FOR REFERENCE DOOR INTERLOCK POWER SUPPLY IS SCHLAGE MODEL 900-4RL BY OTHERS. B. CLIENT RESERVES THE RIGHT TO REVIEW AND APPROVE ALL PRESS-RELATED COPY AND MAY F. COMPLETE ALL TESTING AND SYSTEMS COMMISSIONING AS SPECIFIED. WITHHOLD CONSENT FOR RELEASE OF SUCH COPY,WITH OR WITHOUT CAUSE,AT ITS SOLE B. ALL MATERIALS AND INSTALLATION PRACTICES SHALL COMPLY WITH THE APPLICABLE SECTIONS UU. "SECURITY CONTRACTOR"SYSTEMS SECURITY CONTRACTOR WHO HAS BEEN AWARDED THE A. CAREFULLY CHECK SPACE REQUIREMENTS AND THE PHYSICAL CONFINES OF THE AREAS OF WORK G. PROVIDE ALL RECORD AND AS-BUILT DOCUMENTATION AS SPECIFIED. OF THE FOLLOWING TELECOMMUNICATIONS INDUSTRY STANDARDS DISCRETION. CONTRACT TO PERFORM ANY OR All OF THE WORK AS SPECIFIED WITHIN THIS SPECIFICATION TO ENSURE THAT ALL MATERIAL CAN BE INSTALLED IN THE SPACES ALLOTTED THERETO, 1.14 SUPPLEMENTAL CONDITIONS 1. ANSI/TIA/EIA-568-6.1,COMMERCIAL BUILDING TELECOMMUNICATIONS CABLING STANDARD, AND THE ASSOCIATED DRAWINGS. H. PROVIDE MATERIALS AND WORKMANSHIP WARRANTIES AS SPECIFIED. VV. "TCP/IP": TRANSPORT CONTROL PROTOCOL/INTERNET PROTOCOL INCORPORATED INTO INCLUDING ALL WALL MOUNTED PANELS,POWER SUPPLIES,CONDUITS,ETC.... PART 1:GENERAL REQUIREMENTS. I. QUANTITIES OF ALL ITEMS REFLECTED ON DRAWINGS SHALL SUPERSEDE QUANTITIES LISTED A. ALL OF THE SECURITY CONTRACTOR'S WORK SHALL BE TESTED FIND INSPECTED BY ALL B. TRANSMIT TO CONSTRUCTION MANAGER ALL INFORMATION NECESSARY FOR ANY WORK MICROSOFT WINDOWS. HEREIN. IN ANY CASE SUFFICIENT QUANTITIES OF ALL COMPONENTS TO PROPERLY INSTALL AND AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH ALL SPECIFICATIONS. 2. ANSI/TIA/EIA-568-B.2,COMMERCIAL BUILDING TELECOMMUNICATIONS CABLING STANDARD, REQUIRED BY OTHER TRADES AND/OR EQUIPMENT SUBCONTRACTORS IN A TIMELY MANNER TO TERMINATE ALL CABLING SPECIFIED SHALL BE INCLUDED WITHIN THE CONTRACT SUM. COORDINATE AND COOPERATE FULLY AND SHALL PROVIDE AT NO ADDITIONAL COST TO THE PART 2:BALANCED TWISTED-PAIR CABLING COMPONENTS. WW "TELECOMMUNICATIONS":COMMUNICATIONS(EXCHANGE OF INFORMATION)OVER DISTANCE. ENSURE THAT THE PROJECT SCHEDULE IS MAINTAINED AND THAT ALL TRADES/SUBCONTRACTORS THE TRANSMISSION OF INTELLIGENCE COMPRISES VOICE,DATA,VIDEO,IMAGING,AND ANY HAVE THE INFORMATION NECESSARY TO PROPERLY INSTALL ALL NECESSARY CONNECTIONS AND J. REFER TO CONSTRUCTION MANAGER'S REQUIREMENTS FOR ADDITIONAL REQUIRED MEETING OWNER,MANPOWER,BLUEPRINTS,FACILITIES,SCAFFOLDS,ETC.TO REASONABLY ASSIST THE OTHER SIGNALING FOR THE PURPOSE OF THE TRANSFER OF INFORMATION.THIS IS IRRESPECTIVE ATTENDANCE,MEETING REQUIREMENTS,MEETING FREQUENCY,AND MEETING LOCATIONS. INSPECTORS. 3. ANSI/TIA/EIA-568-B.3,COMMERCIAL BUILDING TELECOMMUNICATIONS CABLING STANDARD, EQUIPMENT. OF THE SIGNALING FORMAT WHETHER ANALOG OR DIGITAL,BASEBAND OR BROADBAND,OR OF K. THE OWNER/CLIENT SHALL BE RESPONSIBLE FOR PROVIDING INFORMATION TO THE SECURITY B. UNLESS OTHERWISE INDICATED ALL PERMITS REQUIRED FOR ANY PART OF THE WORK DEFINED PART 3:OPTICAL FIBER CABLING COMPONENTS STANDARD. C. PROVIDE TIMELY NOTICE TO IDENTIFY ALL ITEMS OF WORK THAT REQUIRE ACCESS SO THAT THE A F HE PR AAMMIN F T A E TR CONTR CTOR ORT OG G O HE CC SS CON OL HARDWARE AND CREATION OF HEREIN SHALL BE PROCURED AND PAID FOR BY THE SECURITY CONTRACTOR.THE SECURITY MEDIA TYPE WHETHER COPPER(TWISTED-PAIR OR COAXIAL),FIBER(SINGLE-MODE OR CONSTRUCTION MANAGER MAY ARRANGE FOR SUCH ACCESS WITHIN THE TIME CONSTRAINTS OF 4. ANSI/TIA/EIA-569-A,COMMERCIAL BUILDING STANDARDS FOR TELECOMMUNICATIONS MULTI-MODE),OR OPEN SPACE TRANSMISSION(RADIO RF,MICROWAVE,OR INFRARED). j THE PROJECT SCHEDULE. THE SECURITY SYSTEM DATABASE. CONTRACTOR SHALL DETERMINE ALL PERMITS REQUIRED AND TRANSMIT THIS INFORMATION TO TELECOMMUNICATIONS i5 ANY TRANSMiSSiON,EMISSION,AND RECEPTION OF SIGNS,SIGNALS, 1.07 SCHEDULE THE OWNER. PATHWAYS AND SPACES(FIPS 175-FEDERAL INFORMATION PROCESSING STANDARD) 1.05 CONTRACTURAL REQUIREMENTS WRITINGS,IMAGES,AND SOUNDS THAT IS INFORMATION OF ANY NATURE BY CABLE,RADIO, E. SEE CONSTRUCTION MANAGER'S INSTRUCTIONS FOR INFORMATION DETAILING THE PROJECT C. THE SECURITY CONTRACTOR WARRANTS THAT BOTH THEY AND THEIR SECURITY CONTRACTORS 5. ANSI/TIA/EIA-598-A,OPTICAL FIBER CABLE COLOR CODING OPTICAL OR OTHER ELECTROMAGNETIC MEANS. A. THE SECURITY CONTRACTOR IS TO PROVIDE MATERIALS,EQUIPMENT AND SERVICES,AND ARE LICENSED BY THE STATE AND AS REQUIRED BY LOCAL ORDINANCES. PERFORM ALL NECESSARY PROCEDURES REQUIRED FOR THE INSTALLA710N OF A COMPLETE AND SCHEDULE. XX. "TWAIN": (TECHNOLOGY WITHOUT AN INTERESTING NAME.)A PROGRAMMING INTERFACE THAT D. THE SECURITY CONTRACTOR MUST STATE IF THEY INTEND TO UTILIZE A THIRD-PARTY,AND MUST 6. ANSI/TIA/EIA-606,THE ADMINISTRATION STANDARD FOR THE TELECOMMUNICATIONS LETS A GRAPHICS APPLICATION,SUCH AS AN IMAGE EDITING PROGRAM OR DESKTOP PUBLISHING F. THE SECURITY CONTRACTOR IS RESPONSIBLE TO ORDER AND STAGE ALL MATERIALS DELIVERY IN A OPERATIONAL SECURITY SYSTEM AS INDICATED ON THE DRAWINGS OR SPECIFIED HEREIN. PROVIDE SAID THIRD PARTY NAME,ADDRESS AND QUALIFICATIONS.THE TRIFID PARTY SECURITY INFRASTRUCTURE OF COMMERCIAL BUILDING PROGRAM,ACTIVATE A SCANNER,FRAME GRABBER,OR OTHER IMAGE-CAPTURING DEVICE. TIMELY MANNER;INCLUDING ANY CHARGES TO EXPEDITE DELIVERY OF MATERIALS AND PREMIUM B. IT iS THE INTENT OF THIS SPECIFICATION THAT All ITEMS UNDER THESE SECTIONS BE ENGINEERED, CONTRACTOR{IF ANY)SHALL COMPLY WITH ALL THE SAME RULES,REGULATIONS,LAWS,AND ' TER iB WER PPLY. TIME ASSOCIATED WITH MAINTAINING THE PROJECT SCHEDULE FOR THE SCOPE OF WORK 7. ANSI/TIA/EIA-607,COMMERCIAL BUILDING GROUNDING AND BONDING REQUIREMENTS FOR YY. UPS: LININ RUPT LE PO SU ..-. ASSEMBLED,INSTALLED AND MAINTAINED BY,AND UNDER THE FULL RESPONSIBILITY OF THE CODES,LICENSES,ETC.AS REQUIRED BY THE SECURITY CONTRACTOR AND AS SPECIFIED HEREIN. SECURITY CONTRACTOR,WHETHER THESE PROCESSES ARE ACTUALLY PERFORMED BY SECURITY DEFINED HEREIN. THE CONSULTANT RESERVES THE RIGHT TO APPROVE OR DISAPPROVE ANY THIRD-PARTY SECURITY TELECOMMUNICATIONS ZZ. "WAN': WIDE AREA NETWORK. REVISIONS: g CONTRACTOR OR NOT. 1.08 BID FORMS CONTRACTOR PROPOSED BY CONTRACTOR. AAA. "WAV": THE DIGITAL AUDIO FORMAT USED IN MICROSOFT WINDOWS. 8. ANSI/TIA/EIA-942,TELECOMMUNICATIONS INFRASTRUCTURE STANDARD FOR DATA CENTERS "" C. SECURITY CONTRACTOR RESPONSIBILITIES A. BIDDER EXPERIENCE AND QUALIFICATIONS E. THE SECURITY CONTRACTOR,UPON RECEIVING NOTICE FROM OWNER THAT THEY HAVE BBB. "WIEGAND": PATENTED MAGNETIC PRINCIPLE THAT USES SPECIALLY TREATED WIRES EMBEDDED ISSUED FOR BID-PERMIT 06.06.17 3 IN THE CREDENTIAL CARD. � 1. COMPLY WITH ALL PROJECT SAFETY REQUIREMENTS. THE FOLLOWING ITEMS ARE THE MINIMUM WORK EXPERIENCE REQUIRED FOR CONSIDERATION OF FURNISHED INFERIOR,IMPROPER OR UNSOUND WORK OR MATERIALS(INCLUDING EQUIPMENT) 9. ASTM A513-SPECIFICATION FOR ELECTRIC-RESISTANCE-WELDED CARBON AND ALLOY STEEL M CCC. "WINDOWS": OPERATING SYSTEM BY MICROSOFT CORPORATION. [i 2. SECURITY CONTRACTOR SHAH ASSIST THE ENGINEER AND THE DESIGN TEAM tN CABLING SECURITY CONTRACTOR BID SUBMITTAL. {WHETHER WORKED OR UN-WORKED),OR WORK OR MATERIALS AT VARIANCE WITH THAT WHICH MECHANICAL TUBING iS SPECIFIED,WILL,WITHIN TWENTY-FOUR(24)HOURS,PROCEED TO REMOVE SUCH WORK OR DDD. "WIRING"OR"CABLING":INCLUDES PROVIDING,UNLESS OTHERWISE NOTED,ALL FITTINGS, ', COORDINATING THE SECURITY SYSTEM DESIGN WITH THE CONSTRUCTION MANAGER FOR 1. THE CONTRACTOR REPRESENTS THAT THEY ARE FAMILIAR WITH,AND HAS EXPERTISE IN THE MATERIALS AND MAKE GOOD ALL OTHER WORK OR MATERIALS DAMAGED THEREBY,AND,ATTHE 10. BICSI DISTRIBUTION METHODS AND BEST PRACTICES HANGERS,SUPPORTS,SLEEVES,ETC. IMPLEMENTATION.SPECIFICALLY,THE SECURITY CONTRACTOR SHALL ENSURE THAT WORK OF THIS NATURE AND SCOPE. THE CONTRACTOR FURTHER AGREES THATTHEY SHALL OPTION OF THE OWNER,SHALL IMMEDIATELY REPLACE SUCH WORK OR MATERIALS WITH WORK 1.20 GENERAL ABBREVIATIONS&ACRONYMS EEE. "WORK AREA"(WORK STATION): A BUILDING SPACE WHERE THE OCCUPANTS INTERACT WITH G ELECTRICAL REQUIREMENTS STATED IN THE SPECIFICATION AND SECURITY SYSTEMS DESIGN OR MATERIALS AS SPECIFIED. THE REMOVAL,REPLACEMENT AND REPAIR SHALL BE PERFORMED TELECOMMUNICATIONS TERMINAL EQUIPMENT. THERE MAY BE MORE THAN ONE PROVIDE ALL WORK AS MAY BE REQUIRED TO MAKE A COMPLETE JOB OF THAT WHICH MAY AT SUCH TIMES AND WITH MANPOWER SUFFICIENT,IN THE JUDGMENT OF THE OWNER,SO AS R. ALMS)ACCESS CONTROL AND ALARM MONITORING SYSTEM TELECOMMUNICATIONS OUTLET(TO)OR WORK AREA OUTLET(WAD}IN A WORK AREA OR THERE N ARE PROPERLY INCORPORATED INTO THE GENERAL/MAIN CONTRACTOR'S SCOPE, NOT BE FULLY DEFINED IN THE CONTRACT DOCUMENTS. NOT TO AVOID DISTURBANCE TO OCCUPANTS,OR OTHER ONGOING WORK FOR THE PROJECT. MAY BE ONE MULTI-USER TELECOMMUNICATIONS OUTLET ASSEMBLY(MUTOA)FOR SEVERAL O IMPLEMENTED AND INSTALLED PROPERLY AND ON TIME.THE SECURITY CONTRACTOR SHALL B. (ANSI)AMERICAN NATIONAL STANDARDS INSTITUTE 2. THE CONTRACTOR SHALL COMPLY WITH ALL OF THE LEGAL REGULATIONS,INCLUDING OSHA F. IF THE SECURITY CONTRACTOR DOES NOT REMOVE SUCH UNSOUND WORK WITHIN A WORK AREAS BE RESPONSIBLE FOR THIS SCOPE BY ATTENDING ROUTINE MEETINGS WITH THE C. (CP)DATA GATHERING ACCESS CONTROL PANEL p SAFETY REGULATIONS AND REGULATIONS OF MUNICIPAL CITY,LOCAL,AND OTHER REASONABLE TIME,THE OWNER MAY REMOVE IT AND MAY STORE THE MATERIAL AT THE EXPENSE FFF. WORKMANLIKE":BEFITTING A SKILLED ARTISAN OR CRAFTSPERSON SPECIFIC TO THE FIELD OF N ; CONSTRUCTION MANAGER BEFORE START OF CONSTRUCTION AND DURING CONSTRUCTION. GOVERNMENT AGENCIES HAVING JURISDICTION CONCERNING THE WORK OF THE OF THE SECURITY CONTRACTOR. IF THE SECURITY CONTRACTOR DOES NOT PAY THE EXPENSES OF D. (DAP)DIGITAL ALARM PANEL TELECOMMUNICATIONS UTILIZING AND ADHERING TO THE HIGHEST STANDARDS AND BEST a- 3. THE SECURITY CONTRACTOR SHALL FURNISH ALL SECURITY EQUIPMENT AND MATERIALS CONTRACTOR. THE CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, SUCH REMOVAL WITHIN TEN(10)DAYS'TIME THEREAFTER,THE OWNER MAY,UPON TEN(10) E. (EIA)ELECTRONIC INDUSTRIES ASSOCIATION PRACTICES AS SET FORTH AND/OR DEFINED BY BICSI',ANSI/EIA/TIA,IEEE AND THIS „r• + WHETHER SPECIFICALLY MENTIONED HEREIN OR NOT,TO ENSURE COMPLETE AND OPERATING ORDINANCES,CODES,RULES,AND REGULATIONS BEARING ON THE CONDUCT OF THE WORK. IF DAYS'WRITTEN NOTICE,SELL SUCH MATERIALS AT AUCTION OR AT PRIVATE SALE AND SHALL F. (EEL)ELECTRICAL TESTING LABORATORIES,INC. SPECIFICATION.IT INDICATES A JOB SKILLFULLY DONE,BECOMING A WORKMAN,ESPECIALLY WELL •` ACCOUNT FOR THE NET PROCEEDS THEREOF,AFTER DEDUCTING ALL THE COSTS AND EXPENSES G. (FCC)FEDERAL COMMUNICATIONS COMMISSION PERFORMED. . SYSTEMS. SECURITY CONTRACTOR SHALL PROVIDE A COMPLETE DESCRIPTION OF THE THE CONTRACTOR PERFORMS ANY WORK,WHICH IS CONTRARY TO SUCH LAWS,ORDINANCES, THAT SHOULD HAVE BEEN BORNE BY THE SECURITY CONTRACTOR AND ALL EXPENSES OF THE N PROPOSED SYSTEM OPERATION/SYSTEM CONFIGURATION. THE SECURITY CONTRACTOR SHALL CODES,RULES AND REGULATIONS,THEY SHALL MAKE ALL CHANGES TO COMPLY THEREWITH SALE. H. (IC)INTERCOM COMMUNICATIONS GGG. 'WYSIWYG": (WHAT YOU SEE IS WHAT YOU GET.)TEXT AND GRAPHICS APPEAR ON THE SCREEN ,/ CONFIGURE AND PROGRAM THE SECURITY SYSTEMS BASED ON USER AND BEAR ALL COSTS ARISING THERE FROM. G. THE OWNER SHALL HAVE THE AUTHORITY AT ALL TIMES,UNTIL FINAL COMPLETION ANO I. {IEEE)INSTITUTE OF ELECTRICAL&ELECTRONICS ENGINEERS THE SAME AS THEY WILL PRINT"CONSOLIDATION POINT(CP)":A LOCATION FOR REQUIREMENTS/EQUIPMENT CAPABILITIES AT NO ADDITIONAL COST TO THE OWNER. SPECIFIC ACCEPTANCE OF THE WORK,TO INSPECT AND REJECT WORK AND MATERIALS WHICH IN ITS J. (KVM)KEYBOARD VIDEO MOUSE SWITCH INTERCONNECTION BETWEEN CABLES. 3. THE SECURITY CONTRACTOR SHALL BE FULLY CONVERSANT AND CAPABLE IN THE CABLING OF 1.22 STAFFING PROGRAMMING INFORMATION SHOULD BE COORDINATED WITH THE OWNER,OR PERSON JUDGMENT ARE NOT IN CONFORMITY WITH THE DRAWINGS AND SPECIFICATIONS,AND ITS K. (MTTR)MEAN TIME TO REPAIR / LOW VOLTAGE APPLICATIONS SUCH AS,BUT NOT LIMITED TO DATA,VOICE AND VIDEO CC APPOINTED BY THE OWNER. THE SCOPE OF WORK SHALL INVOLVE COORDINATING WITH THE DECISION IN REGARD TO CHARACTER AND VALUE OF WORK SHALL BE FINAL AND CONCLUSIVE ON L. (MUX)MULTIPLEXER A. THE SECURITY CONTRACTOR SHALL PROVIDE A SUPERVISORY WORK FORCE SUFFICIENT TO p NETWORK SYSTEMS,AND INSTALLATION OF CATEGORY 3,CATEGORY 5E,AND CATEGORY 6 BOTH CONTRACTING PARTIES. IF THE OWNER PERMITS SAID WORK OR MATERIALS TO REMAIN, IT CONTRACTOR,THE OWNER'S IT STAFF,ENGINEER AND LOSS PREVENTION STAFF TO CABLE. M• 'v THE OWNER SHALL BE ALLOWED THE DIFFERENCE IN VALUE OR SHALL AT ITS ELECTION HAVE THE (NEC)NATIONAL ELECTRICAL CODE MAINTAIN EFFICIENT PERFORMANCE OF THE SECURITY CONTRACTOR S RE PON (BILI IE . c ? COORDINATE PATCH PANEL AND PORT IDENTIFICATION AND IP ADDRESS. THE SECURITY N. (NFPA)NATIONAL FIRE PROTECTION ASSOCIATION B. THE SECURITY CONTRACTOR SHALL DESIGNATE IN WRITING TO THE CONSTRUCTION MANAGER A o RIGHT TO HAVE SAID WORK OR MATERIALS REPAIRED OR REPLACED,AS WELL AS THE DAMAGE a CONTRACTOR WILL ALSO PROVIDE ALL NECESSARY LABOR TO PERFORM ALL LENEL 4. THE SECURITY CONTRACTOR SHALL,AT A MINIMUM,POSSESS THE FOLLOWING 0. {OSHA)OCCUPATIONAL SAFETY&HEALTH ADMINISTRATION DEDICATED,FUJI TIME FOREMAN AS CONTACT FOR RESOLUTION OF PROBLEMS,JOB CAUSED THEREBY,ATTHE EXPENSE OF THE SECURITY CONTRACTOR,AT ANY TIME WITHIN ONE o I PROGRAMMING NECESSARY TO PROVIDE A TURN-KEY SYSTEM TO THE OWNER(E.G.,NAMING QUALIFICATIONS: COORDINATION,ADDITIONS,CHANGES,ETC.,WHO SHALL BE PRESENT IN THE FIELD ATALLTIMES YEAR AFTER THE COMPLETION OF THE ENTIRE PROJECT,OR WITHIN SUCH LONGER PERIOD AS MAY P. (POE)POWER OVER ETHERNET DURING THE PERFORMANCE OF THE WORK. DRAWING BY. ALL CARD READERS AND OTHER SECURITY DEVICES IN ACCORDANCE WITH OWNER NAMING A LENEL ENTERPRISE LEVEL CERTIFICATION BE COVERED BY ANY GUARANTY;AND NEITHER PAYMENTS MADE TO THE CONTRACTOR,NOR ANY Q. (PTZ)PAN TILT ZOOM C. THE SECURITY CONTRACTOR'S FOREMAN SHALL HAVE FULL AUTHORITY TO REPRESENT THE E CONVENTIONS,ETC...). OTHER ACTS OF THE OWNER,SHALL BE CONSTRUED AS EVIDENCE OF ACCEPTANCE,WAIVER OR R. (REX)REQUEST TO EXIT SECURITY CONTRACTOR IN MAKING DECISIONS AND EXECUTING THE WORK IN AN ACCEPTABLE 2 - B POSSESS THOSE LICENSES/PERMITS REQUIRED TO PERFORM PHYSICAL PROTECTION ESTOPPELS. 4. THE SECURITY CONTRACTOR SHALL GENERATE ALL SHOP DRAWINGS ANO INFORMATION FOR SYSTEMS(I.E.,ACCESS CONTROL,CCN,AND BURGLAR ALARM SYSTEMS)INSTALLATIONS S. (SMS)SECURITY MANAGEMENT SYSTEM(A.K.A.ACCESS CONTROL AND ALARM MONITORING MANNER. DATE: June 06y 2017 H. ANTE SECUE I Y CONTR C THE OW NER IN CONNECTION WITH LDE FONEY DUE SHALL BE BORNE SYSTEM) D. THE SECURITY CONTRACTOR AS PART OF THIS BID RESPONSE SHALL SUPPLY A RESUME OF THE THE COMPLETE INSTALLATION AND WIRING OF THE SECURITY SYSTEMS.THESE DRAWINGS IN THE JURtSDICTiON{S}OF THE PROJECT LOCATION(S). BY THE SECURITY CONTRACTOR,AND THE OWNER MAY WITHHOLD MONEY DUE OR RECOVER '•C MUST BE SUBMITTED TO THE CONSULTANT FOR APPROVAL BEFORE INSTALLATION OF CABLE C PERSONNEL KNOWLEDGEABLE IN LOCAL,STATE,AND NATIONAL CODES AND MONEY ALREADY PAID UP TO THE EXTENT OF SUCH EXPENSE. T. (TCO)TEMPORARY CERTIFICATE OF OCCUPANCY FOREMAN AND PROJECT MANAGER. JOB NUMBER• 02GPD-170493 a OR EQUIPMENT. ADDITIONAL RELATED CABLING NOT INSTALLED BY THE SECURITY REGULATIONS. ALL WORK SHALL COMPLY WITH THE LATEST REVISION OF CODES OR I. IT FURTHER REPRESENTS,WARRANTS AND COVENANTS THAT IT HAS SUCCESSFULLY TESTED THE U. (TIA)TELECOMMUNICATION INDUSTRIES ASSOCIATION E. THE SECURITY CONTRACTOR SHALL USE ONLY A SKILLED,EXPERIENCED AND RELIABLE WORK m FORCE AND SHALL DISCONTINUE THE SERVICES OF ANYONE EMPLOYED ON THIS PROJECT UPON _.,. .,.... - _ .. - ..,- _...,v...:.. N CONTRACTOR MUST ALSO BE INCLUDED(OR REFERENCED}!N THESE DRAWINGS(I.E. REGULATIONS. WHEN CONFLICT EXISTS BETWEEN OWNER BEST PRACTICES,LOCAL OR DELIVERABLES TO ENSURE THAT THERE Will BE NO ADVERSE EFFECT BY VIRTUE OF DATE V. (UL)UNDERWRITERS'LABORATORIES,INC. WRITTEN REQUEST BY CLIENT OR ITS DESIGNATED PROJECT MANAGER. - 0. TELECOMMUNICATIONS CABLING,ETC.). THE SECURITY CONTRACTOR SHALL PROVIDE NATIONAL CODES OR REGULATIONS,THE MOST STRINGENT CODES OR REGULATIONS CHANGES AT ANY TIME FROM THE DATE HEREOF THROUGH THE END OF YEAR 2020. IN ADDITION W. (UPS)UNINTERRUPTIBLE POWER SUPPLY SYSTEM TI TLE: SHALL BE FOLLOWED. TO ANY OTHER DAMAGES FROM ANY BREACH OF SUCH REPRESENTATIONS,WARRANTIES AND F. CRAFT PERSONNEL SHALL BE QUALIFIED TO PERFORM THE WORK AND BE KNOWLEDGEABLE OF N H ON-GOING SUPERVISION AND COORDINATION DURING THE IMPLEMENTATION PHASE,AS X. (VAC)VOLTS-ALTERNATING CURRENT THE CODES,STANDARDS,SYSTEMS AND ACTIVITIES REQUIRED FOR THIS PROJECT. D PROPOSERS SHALL DOCUMENT A MINIMUM OF FIVE YEARS'EXPERIENCE IN THE COVENANTS,THE SECURITY CONTRACTOR AGREES TO ASSIGN IMMEDIATELY FULLY TRAINED Q• REQUIRED. FABRICATION,ASSEMBLY AND INSTALLATION OF SYSTEMS OF SIMILAR COMPLEXITY AS SENIOR ENGINEERING STAFF,REASONABLY ACCEPTABLE TO THE OWNER,TO WORK Y. (VDC)VOLTS-DIRECT CURRENT 1.23 WORK IN HARMONY P N YS I C A L SECURITY M C.� 5. THE SECURITY CONTRACTOR SHALL PROVIDE ALL INTERCONNECT CABLES(WITHIN SPECIFIED HEREIN.THIS REQUIREMENT SHALL APPLY EQUALLY TO SUPPLIERS AND CONTINUOUSLY TO CORRECT SUCH DELIVERABLES AT NO ADDITIONAL COST OR EXPENSE TO THE Z. (VMS)VIDEO MANAGEMENT SYSTEM M MANUFACTURERS OF THE SECURITY SUBSYSTEMS AND MAJOR COMPONENTS USED ON OWNER,AND WITHOUT INTERRUPTION TO THE OWNERS ONGOING BUSINESS,TIME BEING OF THE A. THE SECURITY CONTRACTOR AND ITS EMPLOYEES SHALL WORK IN HARMONY WITH ALL OTHER C� h t TECHNOLOGY ROOMS,EQUIPMENT RACKS,MILLWORK,DESKS,ETC.).THIS INCLUDES SECURITY CONTRACTORS,CONTRACTORS AND EMPLOYEES WORKING ON THE SITE. S P E C I FI C A TI O N S THIS PROJECT. ESSENCE. THE SECURITY CONTRACTOR FURTHER AGREES THAT IN THE EVENT THEY FAIL TO r M TERMINATION OF ALL CONTROL HARDWARE EQUIPMENTAND INTERCONNECTS AC POWER TO 1.21 GENERAL DEFINITIONS B. REFER TO CONSTRUCTION MANAGER'S REQUIREMENTS FOR ALL WORK IN HARMONY GUIDELINES. p p, E PROPOSAL SUPPORT DOCUMENTATION SHALL INCLUDE THE NAMES,LOCATIONS,AND IMMEDIATELY ASSIGN ACCEPTABLE STAFF UNTIL SUCH DELIVERABLES ARE CORRECTED,THE cy eE LOCK AND CONTROL POWER SUPPLIES. POINTS OF CONTACT FOR AT LEAST THREE INSTALLATIONS OF THE TYPE AND COMPLEXITY OWNER SHALL IMMEDIATELY BE ENTITLED TO SEEK INJUNCTIVE RELIEF,ASA COURT MAY DEEM 1.24 PROJECT MEETINGS 3(o 6. THE SECURITY CONTRACTOR SHALL COORDINATE WITH THE MAIN CONTRACTOR,ELECTRICAL SPECIFIED HEREIN. PROPOSERS SHAH INDICATE THE TYPE OF EACH REFERENCED SYSTEM APPROPRIATE,TO ENFORCE SUCH REMEDY,MONEY DAMAGES BEING INSUFFICIENT TO MAKE THE A. WITH RE T "FURNISH":MEANS TO PURCHASE,PROCURE,ACQUIRE,AND DELIVER COMPLETE SHEET NUMBER: WITH RELATED ACCESSORIES. R. REFER TO CONSTRUCTION MANAGER'S REQUIREMENTS FOR WEEKLY ORSEMI-WEEKLY PROJECT o AND CERTIFY THAT EACH SYSTEM HAS PERFORMED SATISFACTORILY IN THE MANNER OWNER WHOLE. _lc m G CONTRACTOR,SAFETY SYSTEMS CONTRACTOR OR OTHER CONTRACTORS ON ALL SECURITY B. "AS DIRECTED":MEANS AS INSTRUCTED BY THE GENERAL CONTRACTOR. MEETING REQUIREMENTS AND DAILY FOREMAN'S COORDINATION MEETING REQUIREMENTS. o.Q � RELATED ISSUES AND CONCERNS. FOR CLARIFICATION PURPOSES,ALL ISSUES AND CONCERNS INTENDED FOR A PERIOD OF NOT LESS THAN 24 MONTHS. J. ALL HARDWARE,SOFTWARE,AND FIRMWARE PROVIDED AS PART OF THE WORK SHALL SUPPORT C. "BACKBONE":A FACILITY(E.G.,PATHWAY,CABLE,OR CONDUCTORS)BETWEEN PUCS,MDFS,IDES, 1.25 SUBMITTALS 2 N fr F THE SECURITY CONTRACTOR SHALL HAVE LOCAL IN-HOUSE ENGINEERING AND PROJECT A FOUR-DIGIT YEAR DESCRIPTION V) o SHOULD BE DOCUMENTED AND SUBMITTED TO THE CONSULTANT. AND/OR PBX ROOMS WITHIN OR BETWEEN BUILDINGS. a./ , MANAGEMENT CAPABILITIES CONSISTENT WITH THE REQUIREMENTS OF THE WORK. 1.15 COMPLIANCE WITH LAWS A. EACH SUBMITTAL SHALL CONTAIN JOB TITLE AND REFERENCE TO THE APPLICABLE DRAWING AND 4 a v a 7. THE SECURITY CONTRACTOR SHALL ATTEND ALL JOB MEETINGS AS REQUIRED. 5. THE SECURITY CONTRACTOR SHALL PROVIDE A FULL-TIME PROJECT MANAGER WHO IS TO BE D. "BIDDER"-SYSTEMS SECURITY CONTRACTOR SUBMITTING A BID RESPONSE 70 THESE SPECfFICATiON ARTICLE. a> A. BY SUBMITTING A SIGNED PROPOSAL,THE BIDDER ACKNOWLEDGES AND ATTESTS THAT THE SPECIFICATIONS. to PRESENT ON SITE AT ALL TIMES THAT WORK IS ACTIVELY IN PROGRESS.THIS PERSON SHALL BE B. SUBMITTAL LISTS F2 PROPOSED WORK,SERVICES,AND MATERIALS CONFORM TO AND COMPLY WITH ALL APPLICABLE E. CCN": CLOSED-CIRCUIT TELEVISION. COMMENTS' II II E '; v _ ami o - Ci :-... ...__ 1. SECURITY CONTRACTOR SHALL SUBMIT WITH ITS PROPOSAL TO THE CONSTRUCTION MANAGER APPLICABLE CODES AND REQUIREMENTS OF LOCAL AUTHORITIES HAVING JURISDICTION. SYSTEM. DISTINGUISHABLE. B. FURNISH AND INSTALL PEDESTALS IN ACCORDANCE WITH MANUFACTURES MECHANICAL AND t FOR REVIEW AND ACCEPTANCE A LIST OF ALL MATERIAL AND EQUIPMENT MANUFACTURERS E. ELECTRICAL COMPONENT STANDARD-PROVIDE WORK COMPLYING WITH APPLICABLE B. ALL CABLE SHALL BE PLENUM RATED. D. SHALL BE FLEXIBLE VINYL OR OTHER SUBSTRATES TO APPLY EASY AND FLEX AS CABLES ARE BENT. ELECTRICAL INSTALLATION MANUAL AND BEST PRACTICES. c WHOSE PRODUCTS ARE PROPOSED. REQUIREMENTS OF THE APPLICABLE ELECTRICALCODE. C. APPROVED CABLE MANUFACTURER: E. SHALL USE AGGRESSIVE ADHESIVES THAT STAY ATTACHEDTO ALLJACKETTYPES. C. PROVIDE AN EARTH CONNECTION FROM EACH PEDESTAL TO GROUND PER MANUFACTURES F. UL COMPLIANCE-COMPLY WITH REQUIREMENTS OF ISO 159693;14445A,14443B1,14443B2, 1. BELDEN OR TAPPAN PART 3- EXECUTION GUIDELINES. _ C 2. ONLY SPECIFIED MANUFACTURERS SHALL APPEAR ON THE SUBMITTAL LIST. THE COMPLETE EN50133-1:1997. D. LOCATE PEDESTALS AT FINAL POSITIONS ASSURING CORRECT SPACING AND CORRECT ALIGNMENT. SUBMITTAL LIST MUST BE REVIEWED AND ACCEPTED BYTHE ITCONSUL7ANT PRIOR TO 2.02 EQUIPMENT AND MATERIALS-MINIMUM REQUIREMENTS 2. INSTALLER SHALL UTILIZE A COMPOSITE CABLE WHEREVER PRACTICABLE: 3.01 WORKMANSHIP AND GENERAL REQUIREMENTS FOLLOWING MANUFACTURERS INSTALLATION GUIDELINES TO ASSURE PROPER ALIGNMENT, _SUBMITTAL OF THE MANUFACTURER'S PRODUCT DATA. NO SHOP DRAWINGS WILL BE A BELDEN 638AFS CMP OR BELDEN 65$AFS(WHERE LENGTH ALLOWS CABLE CONTAINMENT AND DRILLING LOCATIONS. PROCESSED WITHOUT AN ACCEPTED SUBMITTAL LIST. A. THE MANUFACTURERS AND PRODUCTS SPECIFIED IN THE DOCUMENT ARE TO BE USED. NO ) A. ALL WORK SHALL BE DONE IN A WORKMANLIKE FASHION(SEE DEFINITION OF WORKMANLIKE IN E. SECURE PEDESTALS TO THE FLOOR UTILIZING ALL 8 STUDS. SUBSTITUTIONS OF COMPONENTS SPECIFICALLY REFERENCED WILL BE ALLOWED,WITHOUT PRIOR PART I OF THIS DOCUMENT)OF THE HIGHEST STANDARDS IN THE TELECOMMUNICATIONS B THE INDIVIDUAL CABLE JACKET COLOR CODING SYSTEM SHALL BE AS FOLLOWS: F. LOCATE AND CONCEAL PEDESTAL POWER SUPPLIES WITHIN 50 FEET OF APPLICATION ABOVE AN 3. THE SUBMITTAL LIST SHALL INCLUDE ALL MATERIAL,SYSTEMS AND EQUIPMENT AS LIS I tD WRITTEN OWNER CONSENT AFTER SUBMITTAL REVIEW. INDUSTRY. ALL EQUIPMENT AND MATERIALS ARE TO BE INSTALLED IN A NEAT AND SECURE - HEREIN. B. ALL PRODUCTS AND MATERIALS SHALL BE NEW,CLEAN,FREE OF DEFECTS AND FREE OF DAMAGE 1) LOCK POWER: GRAY MANNER,WHILE CABLES ARE TO BE PROPERLY DRESSED. ACCESSIBLE CEILING OR IN NEAREST SECURITY CLOSET. COORDINATE FINAL LOCATION AND AND CORROSION. B. ALL TERMINATIONS,CABLE MANAGEMENT,CABLE SUPPORTS,AND RACKING METHODOLOGIES ACCEPTABLE MAXIMUM DISTANCE WITH MANUFACTURER,GENERAL CONTRACTOR,OWNER,AND C. MANUFACTURERS PRODUCT DATA 2) CARD READER:ORANGE ARCHITECT/ENGINEER. SHALL BE CONSISTENT THROUGHOUT THE ENTIRE PROJECT AND ALL CABLE SHALL BE DRESSED IN C. ALL PRODUCTS INSTALLED WILL MEET OR EXCEED THE MINIMUM PERFORMANCE REQUIREMENT G. COMMISSIONING 1. SUBMIT MANUFACTURER'S PRODUCT DATA WITHIN THREE(3)DAYS OF EXECUTED CONTRACT AS LISTED IN THE TECHNICAL SPECIFICATION OF THIS DOCUMENT AND ITS CORRESPONDING 3) DOOR CONTACT WHITE ACCORDANCE WITH MANUFACTURER REQUIREMENTS AND APPROVED BY THE OWNER AND FOR ALL PRODUCTS AND EQUIPMENT IN THE SUBMITTAL LIST. ADDENDA. ENGINEER. SECURITY CONTRACTOR SHALL PROACTIVELY COORDINATE METHODOLOGIES 1. AT NO ADDITIONAL EXPENSE TO OWNER ENGAGE A FACTORY AUTHORIZED REPRESENTATIVE D. NO SUBSTITUTION OF PRODUCTS OR SERVICES WILL BE ACCEPTED WITHOUT PRIOR APPROVAL 4) REX/SPARE BLUE ACCORDINGLY. TO OVERSEE AND SUPERVISE THE INSTALLATION,CABLING,INTEGRATION AND 2. MANUFACTURER'S PRODUCT DATA SHALL CONSIST OF ILLUSTRATIONS,CATALOG CUTS, C. ALL DEVICES SHALL BE INSTALLED FLUSH,PLUMB,LEVEL AND SQUARE. COMMISSIONING OF THE OPTICAL TURNSTILE BARRIER SYSTEM. STANDARD SCHEDULES,PERFORMANCE CHARTS,INSTRUCTIONS,BROCHURES,DIAGRAMS, FROM BOTH OWNER AND THE MANUFACTURER PROVIDING THE APPLICATION WARRANTY. D. FOR COMMUNICATION BETWEEN CONTROL PANEL(CP)AND CARD READER(CR)UTILIZE AND OTHER INFORMATION FURNISHED BY THE SECURITY CONTRACTOR TO ILLUSTRATE A 2.03 ACCESS CONTROL PRODUCTS PLENUM-RATED MULTI-CONDUCTOR COMMUNICATION CABLE,WITH: D. PROTECT ALL CABLE AND MATERIALS BEFORE,AFTER,AND DURING INSTALLATION. 2. ADHERE TO MANUFACTURER GUIDELINES IN COMMISSIONING PROCESS. E. CLEAN AND REMOVE ALL DEBRIS. MATERIAL,PRODUCT,OR SYSTEM FOR SOME PORTION OF THE WORK. A. THE FOLLOWING EQUIPMENT LIST CONTAINS APPROVED MANUFACTURER(S)AND MODEL 1. ISO LISTED,NICEIC TYPE CMP F. EXAMINE AND COMPARE THE TELECOMMUNICATIONS CABLING DRAWINGS AND SPECIFICATIONS 3. POWER SUPPLIES-CHECK THE CORRECT CONNECTIONS AND VOLTAGES STORE 3. THE IDENTIFICATION OF ITEMS SUBMITTED IN CATALOG,PAMPHLET,ETC.SHALL BE CLEARLY NUMBERS OF EQUIPMENT REQUIRED FOR THIS PROJECT. IT IS THE CONTRACTOR'S 2. 6-CONDUCTOR,SHIELDED(19 X 30)22 AWG WITH THE DRAWINGS AND SPECIFICATIONS OF OTHER TRADES;REPORT ANY DISCREPANCIES TO NUMBER • RESPONSIBILITY TO PROVIDE AND INSTALL ALL REQUIRED EQUIPMENT TO MEET THE DESIGN4. PEDESTAL CONTROL CARD-DOUBLE-CHECK THE CONNECTIONS AND VOLTAGES BEFORE THE GENERAL CONTRACTOR AND ENGINEER. OBTAIN WRITTEN INSTRUCTIONS FOR NECESSARY MADE IN INK. DATA OF A GENERAL NATURE WILL NOT BE ACCEPTED. OBJECTIVES BASED ON THIS WRITTEN SPECIFICATION AND DRAWINGS. THE CONTRACTOR SHALL APPLYING POWER TO THE CONTROL CARD CORAM, INC. BE RESPONSIBLE FOR PROVIDING ACCURATE QUANTITIES OF DEVICES AND BOARDS/PANELS TO 3. 55 PF/FT.NOMINAL CAPACITANCE BETWEEN CONDUCTORS REVISIONS IN THE PROJECT APPROACH. D. RECORD DRAWINGS TERMINATE THESE DEVICES. 4. 99 PF/FT.NOMINAL CAPACITANCE BETWEEN ONE CONDUCTOR AND OTHER CONDUCTORS G. ALL CABLES SHALL BE DRESSED IN A NEAT MANNER,OBSERVING CABLE BEND RADIUS LIMITS AT 5. OPTICAL SENSORS-CHECK THE TRANSMIT AND RECEIVE CARDS HAVE POWER,AND THE BEAMS 7358 S W DURHAM RD. 1. DURING CONSTRUCTION,THE SECURITY CONTRACTOR SHALL MAINTAIN A COPY OF ALLALL TIMES. CABLE INSULATION SHALL BE PROTECTED AT ALL TIMES. CABLES WITH DAMAGED SPECIFICATIONS AND A COMPLETE SET OF THE CONSTRUCTION DRAWINGS ON THE JOB SITE, B. IF THE CONTRACTOR REQUIRES ADDITIONAL BOARDS/PANELS OR PROCESSORS TO TERMINATE CONNECTED TO SHIELD SHEATHS SHALL BE REPLACED AT NO ADDITIONAL COST TO OWNER. ARE WORKING CORRECTLY PORTLAND, OR 97224 AND OPERATE ORIGINALLY LiSTED DEVICES ON SECURITY DRAWINGS,THE CONTRACTOR SHALL BE MAKING NOTATIONS AND UPDATES THEREON,AS REQUIRED TO PROVIDE AN ACCURATE R 5. NOMINAL OUTSIDE DIAMETER:4.5 MM. H. NO MORE INSULATION THAN IS NEEDED TO TERMINATE THE CABLE iN THIS POSITION SHALL BE 6. MOTOR CONTROLLER CARD-DOUBLE-CHECK THE CONNECTIONS AND VOLTAGES BEFORE RECORD OF ALL INSTALLATIONS PURSUANT TO THE ISSUE OF AS-BUILT DRAWINGS. RESPONSIBLE FOR ALL COSTS INCURRED IN PROCURING,INSTALLING AND PROGRAMMING THOSE STRIPPED FROM THE CABLE. INDIVIDUAL PAIRS SHALL MAINTAIN THE MAXIMUM ATTAINABLE APPLYING POWER TO THE MOTOR CONTROLLER CARD.CHECK THAT COMMUNICATIONS ARE PROJECT 1 I IFC PHARMACY DEVICES.THE CLIENT SHALL NOT BE RESPONSIBLE AND SHALL NOT REIMBURSE THE CONTRACTOR 6. PROVIDE 5 METERS MINIMUM SLACK AT JUNCTION BOX ADJACENT TO CONTROL PANELS(CP) TWIST INTEGRITY AT THE TERMINATION POINT. WORKING CORRECTLY,AND CONFIGURE THE DRIVE SYSTEM DEAL At ,,rC E. AS-BUILT DRAWINGS UNLESS THE NUMBERS OF DEVICES INDICATED ON THE OFFICIAL DRAWING BID SET WERE TO D PPR I. WORK DEEMED NOT TO CONFORM TO THE CABLE DRESSING AND TERMINATION METHODS 1. UPON ACCEPTANCE OF THE WORK,SECURITY CONTRACTOR SHALL SUBMIT TO THE INCREASE;IN WHICH CASE,THE CONTRACTOR SHALL SUBMIT A CHANGE ORDER JUSTIFYING 7. PROVIDE 5 METERS MINIMUM SLACK COILED WITHIN CABLE PULL BOX(JB)ADJACENTTO CARD DESCRIBED WITHIN CONTRACT DOCUMENTS AND THESE SPECIFICATIONS SHALL BE REDRESSED OR 7. FIT THE GLASS PANEL(S) ADDITIONAL HARDWARE COSTS. REMOVED AND REPLACED AS REQUIRED AT THE DIRECTION OF THE OWNER AND/OR THE CONSTRUCTION MANAGER THREE FULL SETS OF AS BUILT DRAWINGS.AS BUILT DRAWINGS READER LOCATION. HOWEVER,ADDITIONAL CABLE SLACK MAY REQUIRED IF THE CABLE 8. TEST THE SYSTEM FOR CORRECT BEHAVIOR,AND SET THE CONTROL CARD CONFIGURATION: �Q SHALL INCLUDE EACH DRAWING INCLUDED IN THE BID SET AS WELL AS ANY ADDITIONAL C. FURNISH AND INSTALL SMS FIELD HARDWARE IN QUANTITIES AND CONFIGURATIONS AS NEEDED PULL BOX IS NOT LOCATED REASONABLY CLOSE TO THE CORRESPONDING DOOR. iN THIS ENGINEER AT NO ADDITIONAL COST TO THE OWNER. W PROJECT NUMBER: 0�06369 DRAWINGS OR SKETCHES ISSUED DURING THE COURSE OF CONSTRUCTION. TO PROVIDE A FULLY OPERATIONAL INSTALLATION AS INDICATED IN DRAWINGS AND SCENARIO,AS A RULE,PROVIDE CABLE SLACK LENGTH EQUAL TO THE DISTANCE FROM THE 3.02 EXAMINATION DiP-SWITCHES AND POTENTIOMETERS • SPECIFICATIONS. 2. AS-BUILT DRAWINGS WILL REFLECT THE ACTUAL MANNER AND CONDITIONS OF INSTALLATION, D. CARD READERS CABLE PULL BOX TO THE CORRESPONDING DOOR,PLUS 3 METERS 9. RE-FIT THE SIDE PANELS A. EXAMINE PATHWAY ELEMENTS INTENDED FOR CABLES. CHECK PATHWAYS,WALL SPACE,AND INCLUDING ALL DELETIONS FROM,ADDITIONS TO OR DEPARTURES FROM THE CONTRACT 1. APPROVED MANUFACTURERS: 8. PLENUM-RATED MULTI-CONDUCTOR POWER CABLE,WITH: OTHER ELEMENTS FOR COMPLIANCE WITH SPACE ALLOCATIONS,WORKING CLEARANCES, 10. POSITION CARD READERS AS CLOSE TO GLASS AS POSSIBLE AND CONDUCT READ/RESPONSE DOCUMENTS. THE MINIMUM REQUIREMENTS INCLUDE: A HID E. FOR 12VDC AND 24VDC POWER APPLICATIONS(CP,CC,ML,EL,IR)UTILIZE PLENUM RATED: INSTALLATION TOLERANCES,HAZARDS TO CABLE INSTALLATION,AND OTHER CONDITIONS TEST WITH CVS PROXIMITY CARDS AND KEY FOBS. KEY FOB READ AND RESPONSE TIME IS ARCHITECT OF RECORD AFFECTING INSTALLATION. CRITICAL FOR THIS APPLICATION. A AS-BUILT DRAWINGS SHALL BE SUBMITTED IN ELECTRONIC FORMAT ON A CD-ROM,IN 1. ISO LISTED,NICEIC TYPE CMP RATED 2. FURNISH AND INSTALL SMS AUTHENTICATION HARDWARE WHERE INDICATED: B. EXAMINE ROUGHING IN FOR LAN AND CONTROL CABLE CONDUIT SYSTEMS TO PCS,CONTROLLERS, AUTOCAD 2002,OR LATER.DWG FILE FORMAT AS WELL AS IN"HARD"PRINTOUT SETS. CARD READERS,AND OTHER CABLE-CONNECTED DEVICES TO VERIFY ACTUAL LOCATIONS OF 11. WHILE FACTORY AUTHORIZED REPRESENTATIVE IS PRESENT ARRANGE FOR AND CONDUCT AN A ALL READERS SHALL BE HID!CLASS SE PLATFORM 13.56 MHZ,READ/WRITE,BLACK,AND 2. OVERALL SHIELD,1-PAIR CABLE,STRANDED CONDUCTORS(7X26)18 AWG CONDUIT AND BACK BOXES BEFORE DEVICE INSTALLATION. ACCEPTANCE DEMONSTRATION WITH OWNER,ARCHITECT AND ENGINEER. B THE AS-BUILT DOCUMENTATION SHALL INCLUDE ALL THE INFORMATION INCLUDED IN THE SHOP DRAWINGS.THE AS BUILT DOCUMENTATION IS INTENDED TO ASSIST THE CONTACTLESS SMART CARD TECHNOLOGY COMPATIBLE. INSTALL WHERE INDICATED ON 3. NOMINAL OUTSIDE DIAMETER:7.3 MM. C. PROCEED WITH INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN 12. GATES SHALL BE CONFIGURED TO FAIL SAFE IN AN OPEN POSITION UPON LOSS OF POWER OR CLIENT IN ROUTINE SYSTEM MANAGEMENT AND ADMINISTRATION. DRAWINGS: 4. PROVIDE 5 METERS MINIMUM SLACK AT JUNCTION BOX ADJACENT TO CONTROL PANELS(CP). CORRECTED. FIRE ALARM. 1) (CLASS SE R15 MULLION READER 3.03 PREPERATION F. RECORD DOCUMENTATION 5. PROVIDE 5 METERS MINIMUM SLACK COILED WITHIN CABLE PULL BOX(JB)ADJACENT TO CARD 3.10 FIRE STOPPING A. COMPLY WITH RECOMMENDATIONS IN SIA CP-01. 1. RECORD DOCUMENTATION WILL CONSIST OF THE FOLLOWING: 2) (CLASS SE R40 READER READER LOCATION. HOWEVER,ADDITIONAL CABLE SLACK MAY BE REQUIRED IF THE CABLE B. COMPLY WITH EIA/TIA-606,"ADMINISTRATION STANDARD FOR THE TELECOMMUNICATIONS A. COORDINATE FIRE STOPPING REQUIREMENTS WITH GENERAL CONTRACTOR. A FOUR(4)COMPLETE SETS OF AS-BUILT DRAWINGS 3) ICLASS SE RK40 KEYPAD READER PULL BOX IS NOT LOCATED REASONABLY CLOSE TO THE CORRESPONDING DOOR. IN THIS INFRASTRUCTURE OF COMMERCIAL BUILDINGS." B. PROVIDE FIRE-RESISTANT SILICONE FOAM FILL TO RESTORE FIRE RATINGS TO ALL WALL OR FLOOR SCENARIO,AS A RULE,PROVIDE CABLE SLACK LENGTH EQUAL TO THE DISTANCE FROM THE OR CEILING PENETRATIONS. FOAM MUST BE UL CLASSIFIED AND MEET NEC AND LOCAL CODE. B FOUR(4)COMPLETE SETS OF TEST DOCUMENTATION 4) (CLASS R90 LONG RANGE READER 6150 CABLE PULL BOX TO THE CORRESPONDING DOOR,PLUS 3 METERS. C. OBTAIN DETAILED PROJECT PLANNING SUIT PROJECT.S FROMANUFACTURER DATA F ACCESS-CONTROL SYSTEM;DEVELOP CUSTOM FORMS TO SUIT FILL IN ALL AVAILABLE FROM C. ALL PENETRATIONS THROUGH FIRE RATED FLOORS AND WALLS SHALL BE SEALED TO PREVENT THE C ONE(1)ORIGINAL AND THREE(3)COPIES OF AU.MANUFACTURER'S WARRANTIES B CONTRACTOR SHALL VERIFY COMPATIBILITY WITH BASE BUILDING READER AND NOTIFY F. FOR COMMUNICATION(STATUS)BETWEEN CONTROL PANEL(CP),AND SECURITY-RELATED PROJECT PLANS AND SPECIFICATIONS AND PUBLISH AS PROJECT PLANNING DOCUMENTS FOR PASSAGE OF SMOKE,FIRE,TOXIC GAS OR WATER THROUGH THE PENETRATION. THE FIRE RATING ENGINEER OF FINDINGS. COMPONENTS AT DOOR(DC,EL,DR,AND IR)UTILIZE PLENUM RATED: REVIEW AND APPROVAL INCLUDING: OF THE PENETRATION SEAL SHALL BE AT LEAST THAT OF THE FLOOR OR WALL INTO WHICH IT IS 2. TEST RESULT REPORTS 1. ISO LISTED,NICEIC TYPE CMP 1. RECORD SETUP DATA FOR CONTROL STATION AND WORKSTATIONS. INSTALLED,SO THAT THE ORIGINAL FIRE RATING OF THE FLOOR OR WALL IS MAINTAINED AS E. POWER SUPPLIES: REQUIRED BY ARTICLE 300-21 OF THE NATIONAL ELECTRIC CODE. A BEFORE SYSTEMS ACCEPTANCE AND COMMISSIONING,SUBMIT SYSTEM TESTING 1. APPROVED MANUFACTURER 2. 2-CONDUCTOR STRANDED(16 X30)18 AWG2. FOR EACH LOCATION,RECORD SETUP OF CONTROLLER FEATURES AND ACCESS REQUIREMENTS. DOCUMENTATION SHOWING METHODS AND RESULTS FOR ALL TESTS PERFORMED. AT A 3. OBTAIN FROM OWNER START AND STOP TIMES FOR TIME ZONES AND HOLIDAYS,AND MATCH TO ALLOW A MINIMUM OF'A"OF FOAM TO FLOW BETWEEN THEM. Nd CABLE MAY TOUCH MINIMUM,THE TEST RESULTS MUST INDICATE: A ALTRONIX 3. OVERALL SHIELD ANOTHER,THEREBY PREVENTING VOIDS FROM FORMING IN THE FIRE STOP. UP ACCESS LEVELS FOR DOORS. �,;..-•. ..� _ _ 1) ALL CARD READERS ARE ACKNOWLEDGED AND OPERATING PROPERLY. 2. FURNISH AND INSTALL ALTRONIX SUPPLIES WITH FIRE ALARM INTERFACE IN QUANTITIES AND 4. NOMINAL OUTSIDE DIAMETER:4.8 MM E. IF PLASTIC CARTRIDGES ARE USED FOR SMALLER INSTALLATIONS,THE CHEMICAL COMPONENTS OF CONFIGURATIONS NECESSARY TO SUPPORT APPLICATION. EQUIP WITH 4-6 HOUR BATTERY 4. CONFIGURE/PROGRAM ALL DEVICES IN ACCORDANCE WITH OWNER STANDARDS. THE FOAM SHALL BE PRE-MEASURED WITHIN THE CARTRIDGES TO ENSURE THE PROPER RATIOS. 2) ALL DOOR-MONITORING DEVICES ARE ACKNOWLEDGED AND OPERATING PROPERLY. 5. PROVIDE 5 METERS MINIMUM SLACK AT JUNCTION BOX ADJACENT TO CONTROL PANELS(CP). F. THE SEALANT SHALL REMAIN RESILIENT AND PLIABLE TO ALLOW FOR THE REMOVAL AND/OR BACKUP. SIZE AS REQUIRED TO OPERATE ALL 12 OR 24 VDC RATED DEVICES,PLUS 50%FUTURE 5. SET UP GROUPS,FACILITY CODES,LINKING,AND LIST INPUTS AND OUTPUTS FOR EACH ADDITION OF CABLE WITHOUT THE NECESSITY OF DRILLING HOLES. _ CONSULTANT: 3) EACH CAMERA IMAGE IS PROPERLY TARGETED AND FOCUSED. GROWTH: 6. FURNISH AND INSTALL 4-CONDUCTOR CABLE 18 AWG FOR ALL DC(DOOR CONTACT SWITCHES). CONTROLLER. G. NO FLAMMABLE MATERIAL MAY BE USED TO LINE THE CHASE OF A HOLE IN WHICH THE FIRE STOP NOTE: REFER TO DRAWINGS AND RISER DIAGRAM FOR DETAILED INSTALLATION GUIDELINES. MATERIAL IS TO BE INSTALLED. 4) PLAYBACK QUALITY OF RECORDED MATERIAL MUST BE ACCEPTABLE TO THE OWNER. A AL1024ULACM(24VDC @ 10 AMP.) THE DESIGN INTENT IS MONITOR SOME DOORS CLIENT-SPECIFIC DOORS FOR BOTH INTERNAL 6. ASSIGN ACTION MESSAGE NAMES AND COMPOSE MESSAGES. H. WHEN DAMMING MATERIALS ARE TO BE LEFT IN PLACE AFTER THE SEAL IS COMPLETE,ALL SUCH 5) THE SECURITY SYSTEM RESPONDS APPROPRIATELY AND ACCEPTABLY WHEN B AL1012ULACM(12VDC @ 10AMP) AND EXTERNAL(THIRD-PARTY)CENTRAL STATION INTRUSION DETECTION REPORTING. CLIENT 7. SETUP ALARMS. ESTABLISH INTERLOCKS BETWEEN ALARMS,INTRUDER DETECTION,AND MATERIALS SHALL BE NON-FLAMMABLE. PROMPTED BY THE FIRE AND SAFETY SYSTEM(S). 3. PROVIDE A TAMPER SWITCH FOR ENCLOSURE DOOR MAY AT ANY TIME REPLACE SPDT DOOR CONTACT(S)WITH DPDT DOOR CONTACT(S)IN A ACAM SYSTEM. I. FIRE STOP SHALL ADHERE TO ITSELF PERFECTLY TO ALLOW ANY AND ALL REPAIRS TO BE MADE MINIMALLY DISRUPTIVE MANNER IN THE FUTURE. WITH THE SAME MATERIAL. IT SHALL ALSO ALLOW FOR VIBRATION,EXPANSION AND/OR 6) THE FIRE AND SAFETY SYSTEM RESPONDS TO THE SECURITY SYSTEM WHEN F. DOOR HARDWARE 8. DEVELOP USER DEFINED FIELDS. CONTRACTION OF ANYTHING PASSING THROUGH THE PENETRATION WITHOUT AFFECTING THE En i neem+ PROMPTED TO DROP POWER TO ELECTROMAGNETIC LOCKS 1. FURNISH AND INSTALL ALL DOOR HARDWARE NOT SPECIFICALLY PROVIDED BY OTHERS. REFER G. FOR RS-485 COMMUNICATION BETWEEN THE CONTROL PANELS AND COMPUTER SERVER UTILIZES PLENUM RATED: 9. DEVELOP SCREEN LAYOUT FORMATS. SEAL,OR CRACKING,CRUMBLING AND SPALLING. s �✓ TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR DOOR HARDWARE SCHEDULE. J. WHEN SEALANT IS INJECTED INTO A PENETRATION,THE FOAM SHALL EXPAND TO SURROUND ALL - T Co nsu itants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• 4rLOPER• DESCRIBED HEREIN. A. CRAFT PERSONNEL WILL BE REQUIRED TO PROVIDE AND USE THE PROPER TOOLS AND TEST C. THE SECURITY CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLIANCE WITH THE REQUIREMENTS C CONCEALED MAGNETIC CONTACT(S),GE MODEL 1078CW OR AS REQUIRED TO SUIT 1. ALL 4-PAIR UTP CABLE SHALL BE CMP RATED AND BE OF THE SAME CATEGORY, EQUIPMENT IN THE PERFORMANCE OF EACH ACTIVITY.THE TOOLS MUST BE IN GOOD WORKING C. "J-HOOKS"SHALL BE INSTALLED AS REQUIRED TO SUPPORT CABLES AND BE PROPERLY ANCHORED OF ALL AUTHORITIES HAVING JURISDICTION OVER THIS WORK,AND SHALL BRING TO THE MATERIAL AND FIELD CONDITIONS)WITH: ( MANUFACTURER AND PERFORMANCE RATING OF THE IT NETWORK SPECIFIED STRUCTURED ORDER,AND THE TEST EQUIPMENT MUST HAVE CURRENT CALIBRATION CERTIFICATES,AS TO THE BUILDING STRUCTURE IN ACCORDANCE WiTH DESIGN TO AVOID ANY CONFLICT WITH EMI IMMEDIATE ATTENTION OF THE CONSTRUCTION MANAGER ANY WORK THAT,AS DESIGNED,WILL CABLING SYSTEM. APPLICABLE, FROM ELECTRICAL CABLES,TRANSFORMERS,MOTORS,ETC.... NOT COMPLY WITH REQUIREMENTS. 1) PROVIDED AND INSTALLED BY SECURITY CONTRACTOR.HOLE DRILLED BY MAIN B. CLIENT AND THE CONSTRUCTION MANAGER RESERVE THE RIGHT TO REVIEW THE TOOL AND TEST D. ALL CABLE SHALL BE ROUTED IN APPROVED PATHWAYS AND SUPPORTED BY DEVICES SPECIFICALLY _ 1.27 SUBSTITUTIONS CONTRACTOR 2. PATCH CORDS: EQUIPMENT LISTS AND MAINTENANCE PROCEDURES OF THE SECURITY CONTRACTOR. DESIGNED TO SUPPORT AND PROTECT LOW VOLTAGE DATA CABLE. D-RINGS AND J-HOOKS SHALL A PATCH CORDS SHALL BE OF THE SAME RATING AND MANUFACTURER AS THE UTP 3.05 STORAGE AND PROTECTION OF MATERIALS BE SIZED TO CORRECTLY SUPPORT THE NUMBER OF CABLES,WHICH PASS THROUGH THEM. EACH A. NO SUBSTITUTIONS WILL BE ACCEPTED WITHOUT WRITTEN PERMISSION FROM ENGINEER. 2) DOOR STATUS MONITORING CABLINGS SYSTEMS D-RING OR J-HOOK SHALL HAVE A MAXIMUM OF 40 PERCENT FILL CAPACITY. INSTALL ADDITIONAL 1.28 PERIODIC FIELD OBSERVATION REPORT A. THE SECURITY CONTRACTOR SHALL ARRANGE AND COORDINATE ALL ACCESS TO THE JOB SiTE SUPPORTS AS REQUIRED AT INTERVALS NO GREATER THAN 5-FEET BETWEEN EACH SUPPORT. 3) FOR DOUBLE DOORS,CONNECT CONTACTS IN SERIES A. THE OWNER'S CONSULTANT SHALL ISSUE FIELD OBSERVATION REPORTS TO THE CONSTRUCTION B FURNISH AND INSTALL S-FOOT PATCH CORDS AS REQUIRED FOR EACH NETWORK CAMERA (DATA CENTER)AND TO THE BASE BUILDING DOCK,AS WELL AS THE RECEIPT,STAGING, ADDITIONAL PROVISIONS SHALL INCLUDE: 4) COORDINATE COLOR,AS NECESSARY LOCATION. MARSHALING,AND SAFE STORAGE OF ALL MATERIALS,TOOLS AND SUPPLIES WITH A PERSON 1. TIE-WRAPS: MANAGER. THE SECURITY CONTRACTOR SHALL IMMEDIATELY REMEDY ANY DEFICIENT WORK. IN SPECIFIED BY GENERAL CONTRACTOR OR CONSTRUCTION MANAGER. THE BASE BUILDING IS NO EVENT SHALL DEFICIENCIES IN THE SECURITY CONTRACiORS WORK CONSTITUTE GROUNDS OR 5) NOTE:INSTALLATION OF MAGNETIC CONTACT IS NOT NECESSARY IF RACK LOCATION TO THE NETWORK VIDEO RECORDING DEVICE FOR EACH CAMERA. SIZE OCCUPIED AND"OFF-LIMITS"TO CONSTRUCTION PERSONNEL. BASIS FOR AN EXTENSION OF THE CONTRACT TIME OR SCHEDULE SUBSET DURATIONS. ELECTROMAGNETIC LOCK EMPLOYS INTEGRAL DOOR STATUS DEVICE. FACTORY TERMINATED PATCH CORD LENGTHS AS REQUIRED. B. ALL MATERIAL DELIVERIES,EITHER BEFORE OR AFTER NORMAL WORKING HOURS,SHALL BE B THE WRAPS MUST NOT BE OVER-CINCHED. THE PLASTIC CABLE TIES MUST BE APPLIED IN SUCH A 1.29 DELIVERY AND HANDLING OF MATERIALS D PATCH CORD CABLE MANAGEMENT: INCLUDED IN THIS PRICING. MANNER THAT THEY CAN BE TURNED AND ADJUSTED BY HAND AFTER INSTALLATION. A. DELIVERY OF MATERIALS:DELIVER MATERIALS(EXCEPT BULK MATERIALS)IN MANUFACTURERS' 1) NEATLY COIL PATCH CABLE SLACK AND SECURE WITH PLENUM RATED VELCRO TYPE C. MATERIAL SHALL BE STORED TO MANUFACTURERS'RECOMMENDATIONS AS A MINIMUM. 2. BEAM CLAMPS SHALL BE STEEL WITH THREADED BOLT TYPE CLOSURE. SPRING STEEL OR UNOPENED CONTAINERS,FULLY IDENTIFIED WITH MANUFACTURERS'NAME,TRADE NAME,TYPE, H. REQUEST-TO-EXIT(PiR),BOSCH MODEL 1601 WITH: D. CABLE MUST BE STORED iN A LOCATION PROTECTED FROM WEATHER OR VANDALISM. CABLE CABLE WRAPS. "QUICK-CUP"TYPE CLAMPS ARE PROHIBITED. CLASS,GRADE,SIZE,AND COLOR. 1. 2.5M BY 3M COVERAGE MAY BE STORED IN SUB-ZERO TEMPERATURE;HOWEVER INSTALLATION OF CABLE MUST OCCUR IN :-- B. SHIP ALL PRODUCTS AND MATERIALS IN A MANNER THAT WILL PROTECT THEM FROM DAMAGE, 2. ADJUSTABLE PATTERN ANGLE 2) CABLE SLACK SHALL BE SUSPENDED FROM CABLE HANGERS OR SUPPORTS AN ENVIRONMENT NOT LESS THAN 32 DEGREES FAHRENHEIT AND NOT MORE THAN 140 DEGREES 3. FURNISH AND INSTALL GROMMETS WHEREVER CABLE PASSES THROUGH STUDDED WALLS AND • WEATHER,AND ENTRY OF DEBRIS. IF ITEMS ARE DAMAGED,DO NOT INSTALL,BUT TAKE SPECIFICALLY DESIGNED FOR THE INTENDED PURPOSE OF UTP CABLE MANAGEMENT FAHRENHEIT. EQUIP ALL CONDUITS WITH GROMMETS TO PREVENT DAMAGE TO CABLE SHEATHES. SEAL • IMMEDIATE STEPS TO OBTAIN REPLACEMENT. 3. 12 OR 24 VDC FAIL-SAFE OPERATION. AND SHALL NOT BE SUPPORTED OR COME INTO CONTACT THE CEILING DECK. E. ANY PROTECTION AGAINST VANDALISM WILL BE AT SECURITY CONTRACTOR EXPENSE AS WILL ANY 3.12 GROUNDING COSTS ASSOCIATED WITH REPLACEMENT OF STOLEN OR DAMAGED MATERIALS. C. OVERTIME DELIVERY MAY BE REQUIRED FOR THE ANY/ALL DELIVERIES,DEPENDING ON CURRENT 4. MOUNTED ON CEILING ABOVE ACCESS CONTROL DOOR I. MISCELLANEOUS EQUIPMENT AND HARDWARE,FURNISH AND INSTALL ALL 3.06 PROTECTION OF WORK AND PROPERTY A. COMPLY WITH IEEE 1100,"POWER AND GROUNDING SENSITIVE ELECTRONIC EQUIPMENT." SCHEDULING AND SITE LOGISTICS. SECURITY CONTRACTOR WILL ABSORB THE COSTS ASSOCIATED 1. INTERCONNECT CABLING WITH ANY REQUIREMENTS FOR OVERTIME DELIVERIES IMPOSED BY THE CONSTRUCTION 5. WHITE(VERIFY COLOR WITH ARCHITECT) A. THE SECURITY CONTRACTOR SHALL MAINTAIN AND PROTECT ALL EQUIPMENT,MATERIALS,AND B. GROUND CABLE SHIELDS,DRAIN CONDUCTORS,AND EQUIPMENT TO ELIMINATE SHOCK HAZARD MANAGER. AND TO MINIMIZE GROUND LOOPS,COMMON-MODE RETURNS,NOISE PICKUP,CROSS TALK,AND 2. PLATES,TERMINAL BLOCKS,RACEWAY,AND OTHER CABLE MANAGEMENT HARDWARE TOOLS FROM LOSS OR DAMAGE FROM ALL CAUSES AND AT ALL TIMES,WHILE SECURITY D. THE CONTRACTOR SHALL EXAMINE THE SITE AND THE CONTRACT DOCUMENTS AND REVIEW WITH 6. PROVIDE A 1N4004 DIODE OR BRIDGE RECTIFIER ACROSS INDUCTIVE LOAD TO SUPPRESS OTHER IMPAIRMENTS. CURRENT SPIKES CAUSED BY THE INDUCTIVE LOAD(REFER TO MANUFACTURER'S INSTALLATION 3. CRIMP TYPE CONNECTORS ARE PROHIBITED. ALL CONNECTIONS SHALL BE SOLDERED OR USE CONTRACTOR HAS EQUIPMENT,PERSONNEL,OR WORK TO PERFORM ON SITE. C. BOND SHIELDS AND DRAIN CONDUCTORS TO GROUND AT ONLY ONE POINT IN EACH CIRCUIT. THE OWNER THE DESIGNATED AREAS OF ACCESS,DELIVERY,AND STORAGE FOR THE B. THE SECURITY CONTRACTOR SHALL BE RESPONSIBLE FOR THE RECEIPT,SAFE STORAGE AND CONTRACTOR'S USE. THE CONTRACTOR AGREES THAT SUCH AREAS ARE SATISFACTORY AND INSTRUCTIONS). TERMINAL STRIPS DELIVERY OF MATERIALS AND EQUIPMENT TO THE JOB SITE AND FOR COORDINATION OF SAME D. SIGNAL GROUND: SUFFICIENT FOR THEIR NEEDS IN THE COMPLETION OF THEIR WORK AND IN CONFORMANCE WITH 1. TERMINAL: LOCATE IN EACH EQUIPMENT ROOM AND WIRING CLOSET;ISOLATE FROM POWER 7. 30 VDC,1 AMP RATED RELAYS 4. RELAYS ETC. WITH THE CONSTRUCTION MANAGER. MATERIAL AND EQUIPMENT SUBJECT TO DAMAGE BY THE TERMS OF THIS CONTRACT. NATURAL ELEMENTS SHALL BE STORED IN A MANNER SUITABLY SHELTERED FROM THE ELEMENTS SYSTEM AND EQUIPMENT GROUNDING. E. THE CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE AND MAINTAIN THEIR STORAGE FACILITY. 8. COORDINATE COLOR AND AESTHETICS REQUIREMENTS WITH THE ARCHITECT 5. ENCLOSURES,JUNCTION BOXES FOR ADDITIONAL EQUIPMENT(BATTERIES,ETC),iF NECESSARY. BUT READILY ACCESSIBLE FOR INSPECTION OR IN A WEATHER-TIGHT ENCLOSURE SUPPLIED BY THE 2, BUS: MOUNT ON WALL OF MAIN EQUIPMENT ROOM WITH STANDOFF INSULATORS. IF THIS STORAGE FACILITY IS REQUIRED TO BE ON-SITE IT SHALL BE THE CONTRACTOR'S SECURITY CONTRACTOR. RESPONSIBILITY TO COORDINATE THE SIZE AND SPATIAL REQUIREMENTS WITH THE GENERAL 2.04 BURGLAR ALARM 6. TO ENSURE COMPLETE,OPERATIONAL ACCESS CONTROL SYSTEM. C. THE SECURITY CONTRACTOR SHALL NOT STORE OR PLACE MATERIAL ON FLOORS iN EXCESS OF THE 3. BACKBONE CABLE: EXTEND FROM SIGNAL GROUND BUS TO SIGNAL GROUND TERMINAL IN CONTRACTOR,CLIENT AND/OR THEIR REPRESENTATIVES.THE CONTRACTOR SHALL ASSUME FULL A. INTRUSION DETECTION/BURGLAR ALARM 2.07 CABLE HANGERS AND SUPPORTS FLOORS'DESIGNED LOAD LIMITS. EACH EQUIPMENT ROOM AND WIRING CLOSET. RESPONSIBILITY FOR BOTH THEIR STORAGE FACILITY AND ALL CONTENTS THEREIN,UNLESS 1. FURNISH AND INSTALL ALL PANELS,INTERFACE MODULES,CABLES AND CONNECTORS IN 3.07 CLEANUP OTHERWISE INDICATED BY RESPONSIBLE PARTIES. A. J-HOOK CABLE HANGER AND SUPPORT COMPONENTS SHALL BE FURNISHED AND INSTALLED IN 3.13 CORE DRILLING-BY ELECTRICAL CONTRACTOR QUANTITIES AND CONFIGURATIONS REQUIRED TO MONITOR SPECIFIED ALARM POINTS F. THE CONTRACTOR SHALL PROVIDE PROTECTION NECESSARY TO SAFEGUARD THEIR WORK FROM INCLUDING BUT NOT LIMITED TO: SUFFICIENT QUANTITIES TO ROUTE ALL TELECOMMUNICATIONS CABLING NOT IN UNDER FLOOR A. REFER TO CONSTRUCTION MANAGER'S REQUIREMENTS FOR CLEANUP REQUIREMENTS AND ANY A. CORE DRILLING AND THE INSTALLATION OF CONDUITS,FIRE RATED POKE THROUGH FITTINGS, DAMAGE BY THEIR OPERATIONS AND THE OPERATIONS OF OTHERS. CABLE TRAY AS SHOWN ON DRAWINGS. LEED DEBRIS DISPOSAL REQUIREMENTS. �.,. .. B. l-HOOK CABLE SUPPORTS SHALL PROVIDE A BEARING SURFACE OF SUFFICIENT WIDTH TO COMPLY B. UNLESS OTHERWISE INDICATED CLEANUP AND REMOVAL OF DEBRIS IS THE RESPONSIBILITY OF AND RACEWAYS REQUIRED TO ROUTE COPPER AND FIBER OPTIC CABLING WILL BE FURNISHED 1.30 WARRANTY A D1260B AND INSTALLED BY PARTIES AS INDICATED BY CONTRACT DOCUMENTS. REVISIONS: WITH REQUIRED BEND RADII OF HIGH-PERFORMANCE CABLES;UL LISTED. THE SECURITY CONTRACTOR.IF THE SECURITY CONTRACTOR DOES NOT CLEANUP AND REMOVE A. SMS SOFTWARE AND FIELD HARDWARE WARRANTY B D1825 POPEX C. J-HOOK CABLE SUPPORTS SHALL HAVE FLARED EDGES TO PREVENT DAMAGE WHILE INSTALLING DEBRIS PRIOR TO CONCLUDING ITS WORK THE SAME DAY,THE CONSTRUCTION MANAGER WILL B. COORDINATE WITH GENERAL CONTRACTOR AND ELECTRICAL CONTRACTOR FOR ALL CORING 01 31 1. SMS SOFTWARE SHALL BE WARRANTED FOR A PERIOD OF ONE(1)YEAR FROM THE DATE OF CABLES. PERFORM THIS FUNCTION AND THE SECURITY CONTRACTOR WILL BE BACK CHARGED FOR THIS REQUIREMENTS. I SSU ED FOR BID PERMIT 06 06.17 v SHIPMENT FROM THE MANUFACTURER TO BE FREE OF DEFECTS AND WILL FUNCTION IN C D8129 POPIT WORK. 3.14 CABLING D. J-HOOK CABLE SUPPORTS SIZED 1 5/16"AND LARGER SHALL HAVE A CABLE RETAINER STRAP TO an SUBSTANTIAL ACCORDANCE TO THE PUBLISHED SPECIFICATION. D DX4020 NETWORK INTERFACE MODULE(S) PROVIDE CONTAINMENT OF CABLES WITHIN THE HANGER. THE CABLE RETAINER STRAP SHALL BE C. THE SECURITY CONTRACTOR WILL BE HELD ACCOUNTABLE FOR ANY DAMAGE DONE TO THE A. COMPLY WITH NECA 1,"GOOD WORKMANSHIP IN ELECTRICAL CONTRACTING." O REMOVABLE AND REUSABLE AND BE SUITABLE FOR USE IN AIR HANDLING SPACES. PROPERTY OR WORK OF OTHER TRADES(I.E.CEILING TILE,PAINTED WALLS,ETC.)AND WILL BE B. INSTALL CABLES AND WIRING ACCORDING TO REQUIREMENTS IN DIVISION 28 SECTION n 2. SMS FIELD HARDWARE SHALL BE WARRANTED FOR A PERIOD OF TWO(2)YEARS FROM THE E LENEL/BOSCH SUPPORTED API BACK CHARGED FOR ANY REQUIRED REPAIRS INCLUDING CHARGES TO EXPEDITE DELIVERY OF E. J-HOOK CABLE SUPPORTS SHALL HAVE AN ELECTRO-GALVANIZED OR G60 FINISH AND SHALL BE "CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY." DATE OF SHIPMENT FROM THE MANUFACTURER,WILL BE FREE FROM DEFECTS AND WiLL RATED FOR INDOOR USE IN NON-CORROSIVE ENVIRONMENTS. MATERIALS AND PREMIUM TIME ASSOCIATED WITH SUCH REPLACEMENT AND/OR REPAIR. C. WIRING METHOD: INSTALL WIRING IN RACEWAY AND CABLE TRAY EXCEPT WITHIN CONSOLES, CL FUNCTION IN GENERAL ACCORDANCE WITH THE PRODUCT SPECIFICATIONS. D. THE CONTRACTOR SHALL UTILIZE GOOD HOUSEKEEPING PRACTICE WITH RESPECT TO THEIR WORK F. STAINLESS STEEL J-HOOK CABLE SUPPORTS ARE INTENDED FOR INDOOR AND OUTDOOR USE IN CABINETS,DESKS,AND COUNTERS. CONCEAL RACEWAY AND WIRING EXCEPT IN UNFINISHED CNI 3. SMS THIRD PARTY DEVICE WARRANTIES ARE TRANSFERRED FROM THE MANUFACTURER TO R. SYSTEM REQUIREMENTS NON-CORROSIVE ENVIRONMENTS OR WHERE ONLY MILDLY CORROSIVE CONDITIONS APPLY. INCLUDING CLEANUP OF ALL DIRT AND DEBRIS CREATED BY THE CONTRACTOR DURING THEIR SPACES. O 1. VIDEO-SIGNAL FORMAT SHALL COMPLY WITH NTSC STANDARDS.ADD CAMERAS TO EXISTING INSTALLATION OPERATIONS ON A DAILY BASIS. ALL WORK SHALL BE PERFORMED IN A THE CONTRACTOR,WHICH WILL THEN TRANSFER THIRD PARTY WARRANTIES TO THE OWNER. G. J-HOOK CABLE SUPPORTS SHALL BE: D. WIRING METHOD: INSTALL WIRING IN RACEWAY AND CABLE TRAY EXCEPT WITHIN CONSOLES, B SYSTEM.IF PANEL PORTS ARE UNAVAILABLE CONTACT OWNER AND ENGINEER IMMEDIATELY. WORKMANLIKE MANNER BEFITTING A SKILLED ARTISAN OR CRAFTSPERSON SPECIFIC TO THE FIELD O 1. ERICO CABLECATTM J-HOOK SERIES CAT12,CAT21,CAT32,CAT64,CAT2ISS,CAT32SS,CAT64SS; CABINETS,DESKS,AND COUNTERS AND EXCEPT IN ACCESSIBLE CEILING SPACES AND IN GYPSUM N B. WARRANT ALL EQUIPMENT,NOT COVERED BY MANUFACTURER AND ASSOCIATED INSTALLATION OF SECURITY AND TELECOMMUNICATIONS LOW VOLTAGE CABLING UTILIZING AND ADHERING TO (nB. VIDEO SURVEILLANCE SYSTEM(CLIENT PROVIDED-CURRENTLY INSTALLED FOR INFORMATION) CAT-CMTM DOUBLE J-HOOK CAT100CM;CAT-CMTM U-HOOK SERIES CAT200CMLN, THE HIGHEST STANDARDS AND BEST PRACTICES AS SET FORTH AND/OR DEFINED BY BICSI®, BOARD PARTITIONS WHERE UNENCLOSED WIRING METHOD MAYBE USED. USE NRTL-LISTED LABOR FOR A PERIOD OF ONE(1)YEAR FROM DATE OF BENEFICIAL USE. CAT300CMLN;AND CAT-CMTM RETAINER CATRT200CM,CATRT300CMPLENUM CABLE IN ENVIRONMENTAL AIR SPACES,INCLUDING PLENUM CEILINGS. CONCEAL ANSI/EIA/TIA,IEEE,AND THIS SPECIFICATION.ADDITIONAL REQUIREMENTS SHALL INCLUDE: C. PROVIDE A ONE-YEAR WARRANTY ON THE WORK.IF,WITHIN ONE YEAR AFTER THE DATE OF FINAL 1. APPROVED MANUFACTURER RACEWAY AND CABLES EXCEPT IN UNFINISHED SPACES. •�' ACCEPTANCE OF THE WORK OR WITHIN SUCH LONGER PERIOD OF TIME AS MAY BE PRESCRIBED BY H. IF REQUIRED,THE MULTI-TIER SUPPORT BRACKET MAY BE ASSEMBLED TO MANUFACTURER 1. REFER TO GENERAL CONTRACTOR'S REQUIREMENTS FOR ADDITIONAL REQUIREMENTS. 3 LAW,OR BY THE TERMS OF ANY APPLICABLE SPECIAL WARRANTY REQUIRED BY THE CONTRACT A 3VR 814 MISSION STREET,SUITE 400,SAN FRANCISCO,CA 94103 RECOMMENDED SPECIALTY FASTENERS INCLUDING BEAM CLAMPS,FLANGE CLIPS,C AND Z PURLIN E. INSTALL LAN CABLES USING TECHNIQUES,PRACTICES,AND METHODS THAT ARE CONSISTENT WITH 2. THE INTERIOR OF ALL EQUIPMENT AND CABINETS SHALL BE LEFT CLEAN;EXPOSED SURFACES CATEGORY 6 RATING OF COMPONENTS AND THAT ENSURE CATEGORY 6 PERFORMANCE OF N DOCUMENTS OR PROVIDED BY A MANUFACTURER,ANY OF THE WORK OR EQUIPMENT IS FOUND CLIPS. COMPLETED AND LINKED SIGNAL PATHS,END TO END. Cr) TO BE DEFECTIVE OR NOT IN ACCORDANCE WITH THE CONTRACT DOCUMENTS,THE CONTRACTOR B TELEPHONE:877.387.6061 I. MULTI-TIERED SUPPORT BRACKET SHALL BE: INTERIOR&EXTERIOR SHALL BE CLEANED(DUST-FREE;INCLUDING CABLES AND PATCH CORDS) AND PLATED SURFACES POLISHED. F. INSTALL CABLES WITHOUT DAMAGING CONDUCTORS,SHIELD,OR JACKET. O SHALL CORRECT IT PROMPTLY INCLUDING ALL PARTS AND LABOR AFTER RECEIPT OF NOTICE FROM C 3VR WILL BE PROVIDING AN ENGINEERED SOLUTION FOR THIS PROJECT. REFER TO 1. ERICO CADDY CATHBA AND CABLECATT'"J-HOOKS WITH SCREWS. G. BOXES AND ENCLOSURES CONTAINING SECURITY SYSTEM COMPONENTS OR CABLING,AND WHICH �] THE OWNER TO OS SO UNLESS THE OWNER HAS PREVIOUSLY GIVEN THE CONTRACTOR A WRITTEN PROJECT REFERENCE CODE"CVS FLOWER MOUND TX". THE PRE-PACKAGED SOLUTION 3. TIE WRAPS(WHERE ALLOWED)SHALL BE CUT FLUSH WITH LOCKING MECHANISM AND TURNED ARE EASILY ACCESSIBLE TO EMPLOYEES OR TO THE PUBLIC,SHALL BE PROVIDED WITH A LOCK. ... ..... ACCEPTANCE OF SUCH CONDITION.THIS OBLIGATION SHALL SURVIVE TERMINATION OF THE 2. TEE BAR SUPPORT BRACKET WITH ONE J HOOK CABLE SUPPORT,FACTORY OR JOBSITE WILL BE DESIGNED THE CLIENT AND INCLUDES: SO AS TO PRODUCE AN AESTHETICALLY CONSISTENT VIEW. BOXES ABOVE CEILING LEVEL IN OCCUPIED AREAS OF THE BUILDING SHALL NOT BE CONSIDERED O CONTRACT.THE OWNER WILL GIVE SUCH NOTICE PROMPTLY AFTER DISCOVERY OF THE ASSEMBLED;RATED FOR INDOOR USE IN NON-CORROSIVE ENVIRONMENTS;CULUS LISTED; TO BE ACCESSIBLE. JUNCTION BOXES AND SMALL DEVICE ENCLOSURES BELOW CEILING LEVEL AND CONDITION.SUCH NOTICE SHALL BE PROVIDED BY OWNER REPRESENTATIVES,TO BE IDENTIFIED D HYBRID NETWORK VIDEO RECORDER(S)-HVA-5532-00871 ERICO CADDY CAT12TS,CAT21528,CAT32528 4. DEVICES SHALL BE CLEAN(NO SMUDGES,FINGERPRINTS,DUST,ETC.),MOUNTED AT A EASILY ACCESSIBLE TO EMPLOYEES OR THE PUBLIC SHALL BE COVERED WITH A SUITABLE COVER EITHER VERBALLY OR IN WRITING. 4:4E KEYBOARD(S),JOY STiCK,MONITORS,MOUSE J. FASTENER TO WIRE/ROD WITH ONE J-HOOK CABLE SUPPORT,FACTORY OR JOBSITE ASSEMBLED; CONSISTENT HEIGHT THROUGHOUT THE PROJECT AS COORDINATED WITH THE ARCHITECT AND PLATE AND SECURED WITH TAMPERPROOF SCREWS. D. THE ONE-YEAR WARRANTY PERIOD SHALL BEGIN UPON FINAL ACCEPTANCE OF THE COMPLETED DISCIPLINES AND SHALL BE INSTALLED LEVEL H. INSTALL END-OF-LINE RESISTORS AT THE FIELD DEVICE LOCATION AND NOT AT THE CONTROLLER 0 WORK OR COMMENCEMENT OF BENEFICIAL USE BY THE OWNER,WHICHEVER OCCURS FIRST RATED FOR INDOOR USE IN NON-CORROSIVE ENVIRONMENTS;CULUS LISTED;ERICO CADDY O.. F CLIENT WORKSTATIONS FOR GUARD STATIONS(RECEPTION) CAT124Z34,CAT126Z34,CAT214Z34,CAT216Z34,CAT324Z34 OR CAT326234. OR PANEL LOCATION. DRAWING BY: WHERE: 5. REPAIR DAMAGE TO FINISH SURFACES RESULTING FROM WORK UNDER THIS SECTION. E 1. FOR PURPOSES OF WARRANTY CONSIDERATION,FINAL ACCEPTANCE SHALL BE DEFINED AS THE C. PATCH CORDS K. FASTEN TO BEAM OR FLANGE WITH ONE J-HOOK CABLE SUPPORT,FACTORY OR JOBSITE 3.15 CABLE APPLICATION p DATE ON WHICH THE OWNER FORMALLY ACKNOWLEDGES ACCEPTANCE OF THE COMPLE LED ASSEMBLED;RATED FOR INDOOR USE IN NON-CORROSIVE ENVIRONMENTS;CULUS LISTED;ERICO 6• REMOVE MATERIAL AND EQUIPMENT FROM AREAS OF WORK AND STORAGE AREAS(WORK A. COMPLY WITH EIA/71A-569,"COMMERCIAL BUILDING STANDARD FOR TELECOMMUNICATIONS DATE: June 06, 2017 8 WORK. 1. FURNISH AND INSTALL ALL FIBER OPTIC,UTP AND COAXIAL PATCH CORDS AS REQUIRED TO CABLECATTM J-HOOK SERIES CAT12,CAT21,CAT32,CAT64 WITH CADDY BEAM CLAMPS AND AREAS SHALL BE FREE OF DUST AND WIRE CLIPPINGS). ABOVE TILE AREAS(WHERE PATHWAYS AND SPACES." SUPPORT VIDEO SYSTEM. PATCH CORDS MUST MATCH NETWORK STRUCTURED CABLING CADDY FLANGE CLIPS. �+ APPLICABLE)SHALL BE CLEANED OF CABLE SCRAP,CLIPPINGS,TAILS,ETCETERA. COORDINATE .-. B. CABLE APPLICATION REQUIREMENTS ARE MINIMUM REQUIREMENTS AND SHALL BE EXCEEDED IF 2. FOR PURPOSES OF WARRANTY CONSIDERATION,BENEFICIAL USE SHALL BE DEFINED AS THE MANUFACTURER WARRANTY REQUIREMENTS. L. FASTEN TO WALL,CONCRETE,OR JOIST WITH ONE J-HOOK CABLE SUPPORT,FACTORY OR JOBSITE WASTE DISPOSAL WITH APPLICABLE PROJECT LEER REQUIREMENTS. RECOMMENDED OR REQUIRED BY MANUFACTURER OF SYSTEM HARDWARE. JOB NUMBER: 02GPD-170493 v DATE ON WHICH THE OWNER COMMENCES NORMAL OPERATION OF THE COMPLETED ASSEMBLED;RATED FOR INDOOR USE IN NON-CORROSIVE ENVIRONMENTS,CULUS LISTED;ERICO C. RS 232 CABLING: INSTALL AT A MAXIMUM DISTANCE OF 50 FEET(15 M). N SYSTEMS. D. INDOOR FIXED IP CAMERAS CABLECATTM J-HOOK SERIES CAT12,CAT21,CAT32,CAT64,WITH CADDY ANGLE BRACKET 7. ALL EQUIPMENT SHALL BE CLEAN FROM DIRT,DUST,AND FINGERPRINTS PRIOR TO FINAL = sv 1. APPROVED MANUFACTURERS/PRODUCT LiNES M. FASTEN TO THREADED ROD WITH ONE 1-HOOK CABLE SUPPORT,FACTORY OR JOBSITE ASSEMBLED, ACCEPTANCE. D. RS-485 CABLING: INSTALL AT A MAXIMUM DISTANCE OF 4000 FEET(1220 M). TITLE: RATED FOR INDOOR USE iN NON-CORROSIVE ENVIRONMENTS,CULUS LISTED.THE MULTI-TIERED E. UTP CABLING O H A PROVIDE AND INSTALL AXIS P3364-V SERIES FIXED DOME CAMERA WITH 6MM LENS. SUPPORT BRACKET SHALL HAVE A STATIC LOAD LIMIT OF 300 LBS. 8. ALL CEILING TILES AND ACCESS PANELS SHALL BE CLOSED,FLAT ON FRAMES AND STRAIGHT. 1. COORDINATE SCOPE OF WORK WITH IT CONTRACTOR WHO WILL FURNISH AND INSTALL ALL N PART2 PRODUCTS p PHYSICAL SECURITY FURNISH AND SUPPLY ALL OPTIONAL MOUNTING ACCESSORIES REQUIRES TO SUIS FIELD N. U-NOOKS AND DOUBLE J-HOOK SHALL ATTACH DIRECTLY TO THREADED ROD USING STANDARD 9. ALL SERVICE LOOPS{COILS)SHALL BE NEAT,FASTENED,AND ANCHORED. PREMISE NETWORK CABLE REQUIRED TO SUPPORT PHYSICAL SECURITY SYSTEM UNDER A M b2.01 QUALITY ASSURANCE CONDITIONS. NUTS;ERICO CABLECATTM J-HOOK,CAT12,CAT21,CAT32,CAT64 WITH CADDY CATHBA SERIES; SEPARATE CONTRACT. A. ALL MATERIALS USED SHALL BEAR THE UNDERWRITERS'LABORATORY,INC.LABEL,PROVIDED A 1 INTERIOR DROP CEILING MOUNT-PROVIDE DROP CEILING MOUNT AXIS T94HOSL CAT-CMTM DOUBLE J-HOOK CAT100CM,CAT-CMTM DIRECT MOUNT U-HOOK CAT200CMLN, 10. PLACEMENT OF CABLES ON CABLE TRAY,J-HOOKS,LADDER RACK,AND VERTICAL SPECIFICATIONS CAT300CMLN;OR AFAB SERIES. MANAGEMENT SHALL ENSURE HORIZONTAL STRAIN RELIEF AND ENSURE A CLEAN FLOW OF F. CARD READERS AND KEYPADS: r r7 STANDARD HAS BEEN ESTABLISHED FOR THE MATERIAL IN QUESTION. IP51 RATED RECESSED MOUNT WITH SMOKED DOME. 2.08 LABELING PRODUCTS CABLES FROM PATCH PANEL OR TERMINATION UNIT TO THE SECURITY DEVICE. 1. INSTALL NUMBER OF CONDUCTOR PAIRS RECOMMENDED BY MANUFACTURER FOR THE ,_N B. ALL PRODUCTS AND MATERIALS SHALL BE NEW AND UNUSED,CLEAN,FREE OF DEFECTS,DAMAGE, AND CORROSION. ALL EQUIPMENT PROVIDED BY THE SECURITY CONTRACTOR SHALL BE NEW AND 2) INTERIOR CEILING PENDANT MOUNT LOCATIONS,REQUIRING ADJUSTMENT- FUNCTIONS SPECIFIED. SHEET A. ALL COMMUNICATIONS CABLING LABELS SHALL MEET THE LEGIBILITY,DEFACEMENT,EXPOSURE 3.08 SYSTEM SOFTWARE SHALL MEET OR EXCEED THE LATEST PUBLISHED SPECIFICATIONS OF THE MANUFACTURER IN ALL PROVIDE AXIS T91B51 CEILING MOUNT AND ADHESION REQUIREMENTS OF UL 969. 2. UNLESS MANUFACTURER RECOMMENDS LARGER CONDUCTORS,INSTALL NO.22 AWG WIRE IF cc p1. DEVELOP,INSTALL,AND TEST SOFTWARE AND DATABASES FOR THE COMPLETE AND PROPER RESPECTS. B. SHALL BE PRINTED OR COMPUTER PRINTED TYPE.HAND WRITTEN LABELS OF ANY KIND ARE MAXIMUM DISTANCE FROM CONTROLLER TO THE READER IS 250 FEET(75 M),AND INSTALL P S 6 C. CONTRACTOR SHALL PROVIDE THE LATEST MODEL/REVISION OF A SPECIFIED PIECE OF EQUIPMENT B)COORDINATE WITH CLIENT AND IT CONTRACTOR AND FURNISH AND INSTALL THE OPERATION OF SYSTEMS INVOLVED. ASSIGN SOFTWARE LICENSE(S)TO OWNER. UNACCEPTABLE AND SHALL BE REPLACED BY THE CONTRACTOR AT NO ADDITIONAL COSTTOTHE NO.20 AWG WIRE IF MAXIMUM DISTANCE IS 500 FEET(150 M). 3 C•1WALL-MOUNT INDOOR INLINE MODULES FOR ALL EXTERIOR MOUNTED CAMERAS °(A O _ AND SOFTWARE,AT THE TIME OF INSTALLATION. CUSTOMER. 3.09 OPTICAL TURNSTILES t,o,. D. MATERIALS AND EQUIPMENT SHALL CONFORM TO THE LATEST EDITION OF NATIONAL AND LOCAL 2.06 CABLE(FOR REFERENCE ONLY-CABLE IS FURNISHED AND INSTALLED BY IT CONTRACTOR) C. PROVIDE A VINYL SUBSTRATE WITH A WHiTE PRINTING AREA AND BLACK PRINT.IF CABLE JACKET IS 3. FOR GREATER DISTANCES,INSTALL"EXTENDER"OR"REPEATER"MODULES RECOMMENDED BY 2 . 2 2 ami as CODES AND REQUIREMENTS ADOPTED FOR THE OVERALL PROJECT,AS WELL AS TO ALL A. FURNISH AND INSTALL ALL CABLE NECESSARY TO PROVIDE A COMPLETE A FULLY OPERATIONAL WHITE,PROVIDE CABLE LABEL WITH YELLOW OR ORANGE PRINTING AREA SO LABELS ARE EASILY A. COMPLY WITH NECA 1,"GOOD WORKMANSHIP IN ELECTRICAL CONTRACTING." MANUFACTURER OF THE CONTROLLER. a) = II F- Eii ii COMMENTS: 0d5 . _ ; 4. INSTALL MINIMUM NO.18 AWG SHIELDED CABLE TO READERS AND KEYPADS THAT DRAW 50 CWS MA OR MORE. 5. INSTALL MINIMUM NO.16 AWG CABLE FROM CONTROLLER TO ELECTRICALLY POWERED LOCKS. DO NOT EXCEED 250 FEET(75 M) 3.16 IDENTIFICATION AND LABELING A. EL C EACH BELOW:TRMNAL STRIP AND SCREW TERMINAL IN EACH CABINET,RACK,OR PANEL AS IND 1. ALL WIRING CONDUCTORS CONNECTED TO TERMINAL STRIPS SHALL BE INDIVIDUALLY NUMBERED,AND EACH CABLE OR WIRING GROUP BEING EXTENDED FROM A PANEL OR CABINET TO A BUILDING-MOUNTED DEVICE SHALL BE IDENTIFIED WITH THE NAME AND NUMBER OF THE PARTICULAR DEVICE AS SHOWN. 2. EACH WIRE CONNECTED TO BUILDING-MOUNTED DEVICES IS NOT REQUIRED TO BE NUMBERED AT THE DEVICE IF THE COLOR OF THE WIRE IS CONSISTENT WITH THE ASSOCIATED WIRE CONNECTED AND NUMBERED WITHIN THE PANEL OR CABINET. B. CABLES STORE ICkEIM 1. ALL CABLES SHALL BE LABELED AT EACH END WITHIN 6 INCHES OF THE END OF THE CABLE.THE • CABLE OR ITS LABEL SHALL BE MARKED WITH ITS IDENTIFIER. CORAM, INC.!t 2. BACKBONE CABLES SHALL ADDITIONALLY BE LABELED AT 5-FOOT AFF ON EACH FLOOR LEVEL 7358 S W DURHAM RD. THE CABLE PASSES THROUGH WITHOUT TERMINATING. �ry 3.17 FIELD QUALITY CONTROL PORTLAND,LAND, OR 97224 A.FIELD QUALITY CONTROL EXECUTION PROJECT TFE PHARMACY 1. INSPECT,TEST,AND ADJUST FIELD-ASSEMBLED COMPONENTS AND EQUIPMENT INSTALLATION, T NpR INCLUDING CONNECTIONS,AND TO ASSIST IN FIELD-TESTING. REPORT RESULTS IN WRITING. 2. PERFORM THE FOLLOWING FIELD TESTS AND INSPECTIONS AND PREPARE TEST REPORTS: CS PROJECT NUR 0106369 • A LAN CABLE PROCEDURES: INSPECT FOR PHYSICAL DAMAGE AND TEST EACH CONDUCTOR SIGNAL PATH FOR CONTINUITY AND SHORTS. USE CLASS 2,BI-DIRECTIONAL,CATEGORY 6 TESTER. TEST FOR FAULTY CONNECTORS,SPLICES,AND TERMINATIONS. TEST ; ACCORDING TO TIA/EIA-568-1,"COMMERCIAL BUILDING TELECOMMUNICATIONS n ARDHITECT OF REC{�RD CABLING STANDARDS-PART 1 GENERAL REQUIREMENTS." LINK PERFORMANCE FOR UTP CABLES MUST COMPLY WITH MINIMUM CRITERIA IN TIA/EIA-568-B. B TEST EACH CIRCUIT AND COMPONENT OF EACH SYSTEM. TESTS SHALL INCLUDE,BUT ARE NOT LIMITED TO,MEASUREMENTS OF POWER SUPPLY OUTPUT UNDER MAXIMUM LOAD, SIGNAL LOOP RESISTANCE,AND LEAKAGE TO GROUND WHERE APPLICABLE. SYSTEM COMPONENTS WITH BATTERY BACKUP SHALL BE OPERATED ON BATTERY POWER FOR A PERIOD OF NOT LESS THAN 10 PERCENT OF THE CALCULATED BATTERY OPERATING TIME. PROVIDE SPECIAL EQUIPMENT AND SOFTWARE IF TESTING REQUIRES SPECIAL OR DEDICATED EQUIPMENT. C OPERATIONAL TEST: AFTER INSTALLATION OF CABLES AND CONNECTORS,DEMONSTRATE PRODUCT CAPABILITY AND COMPLIANCE WITH REQUIREMENTS. TEST EACH SIGNAL PATH FOR END-TO-END PERFORMANCE FROM EACH END OF ALL PAIRS INSTALLED. REMOVE TEMPORARY CONNECTIONS WHEN TESTS HAVE BEEN SATISFACTORILY COMPLETED. D VERIFY OPERATION OF AUTO-IRIS LENSES. E SET BACK-FOCUS OF FIXED FOCAL LENGTH LENSES. AT FOCUS SET TO INFINITY,SIMULATE NIGHTTIME LIGHTING CONDITIONS BY USING A DARK GLASS FILTER OF A DENSITY THAT PRODUCES A CLEAR IMAGE. ADJUST UNTIL IMAGE IS IN FOCUS WITH AND WITHOUT THE FILTER. WORK WITH ENGINEER TO ESTABLISH A BENCHMARK FOR THE VIEW CHARACTERISTICS AND REPLICATE QUALITY STANDARD ON ALL CAMERAS. F SET BACK-FOCUS OF ZOOM LENSES. AT FOCUS SET TO INFINITY,SIMULATE NIGHTTIME _ ---,-- -- - LIGHTING CONDITIONS BY USING A DARK GLASS FILTER OF A DENSITY THAT PRODUCES A CLEAR IMAGE. ADDITIONALLY,SET ZOOM TO FULL WIDE ANGLE AND AIM CAMERA AT AN OBJECT 50 TO 75 FEET AWAY. ADJUST UNTIL IMAGE IS IN FOCUS FROM FULL WIDE ANGLE • TO FULL TELEPHOTO,WITH THE FILTER IN PLACE. (�✓�(`+) • G SET AND NAME ALL PRESET POSITIONS(WHERE APPLICABLE);CONSULT OWNER'S PERSONNEL. H CONNECT AND VERIFY RESPONSES TO ALARMS. I VERIFY OPERATION OF CONTROL-STATION EQUIPMENT. B. REMOVE AND REPLACE MALFUNCTIONING DEVICES AND CIRCUITS AND RETEST AS SPECIFIED ABO T SCHEDULE: SCHEDULE TESTS AFTER PRE-TESTING HAS BEEN SUCCESSFULLY COMPLETED AND Engineers+ VE. C. TES SYSTEM HAS BEEN IN NORMAL FUNCTIONAL OPERATION FOR AT LEAST 14 DAYS. PROVIDE A Consultants MINIMUM OF 10 DAYS'NOTICE OF TEST SCHEDULE. tt - D. OPERATIONAL TESTS: PERFORM OPERATIONAL SYSTEM TESTS TO VERIFY THAT SYSTEM COMPLIES WITH SPECIFICATIONS. INCLUDE ALL MODES OF SYSTEM OPERATION. TEST EQUIPMENT FOR PROPER OPERATION IN ALL FUNCTIONAL MODES. E. REMOVE AND REPLACE MALFUNCTIONING ITEMS AND RETEST AS SPECIFIED ABOVE. 155 SEAPORT BOULEVARD F. RECORD TEST RESULTS FOR EACH PIECE OF EQUIPMENT. SEAPORT WEST,FLOOR 2 G. RETEST: CORRECT DEFICIENCIES IDENTIFIED BY TESTS AND OBSERVATIONS AND RETEST UNTIL BOSTON, MA 02210 SPECIFIED REQUIREMENTS ARE MET. 3.18 PHYSICAL INSPECTION P.617.443.4950.F.617.443.4959 A. PRIOR TO CONDUCTING ANY TRANSMISSION TESTING,THE FOLLOWING VISUAL INSPECTIONS SHALL BE PERFORMED: 1. VERIFY THAT ALL CABLE HAS BEEN INSTALLED TO FULL COMPLIANCE WITH THE PROPOSAL SPECIFICATIONS. D�����■ • 2. CHECK FOR PHYSICAL DAMAGE TO THE FIBER DISTRIBUTION PANELS AND COPPER {•j f TERMINATION HARDWARE. REPLACE AT NO CHARGE TO OWNER AS REQUIRED. B. CHECK THAT ALL CABLING IS PROPERLY JACKETED,PROPERLY LABELED AT BOTH ENDS OF THE CABLE,AND TERMINATION HARDWARE IS COMPLETED. C. VERIFY THAT ALL CABLE BENDS ARE WITHIN THE MANUFACTURER'S SPECIFIED BEND RADIUS. D. VERIFY THAT ALL CABINETS AND RACKS(WHICH REQUIRE GROUNDING)ARE PROPERLY GROUNDED AND COMPLY WITH NATIONAL AND LOCAL ELECTRICAL CODES AND ANSI/TIA/EIA-607 STANDARDS FOR TELECOMMUNICATIONS BONDING AND GROUNDING. E. VERIFY THAT THE CABLES ARE PROPERLY APPROVED AND STRUCTURALLY SUPPORTED FOR TERMINATION. F. VERIFY THAT THE REQUIREMENTS OF ALL AUTHORITIES HAVING JURISDICTION HAVE BEEN SATISFIED. 3.19 GENERAL TESTING REQUIREMENTS A. BEFORE AN APPLICATION FOR FINAL ACCEPTANCE OF THE WORK WILL BE CONSIDERED,ALL TESTS REQUIRED BY THIS DOCUMENT SHALL BE SATISFACTORILY COMPLETED,WITH FULL TEST RESULTS SUBMITTED AND REVIEWED,AND MANUFACTURER'S CERTIFICATION ISSUED. B. ALL COMPONENTS OF INSTALLED CABLE PLANT MUST CONFORM TO EIA/TIA AND ALL OTHER • RELATED INDUSTRIAL PRACTICES AND STANDARDS,BUILDING TRADES,AND ELECTRICAL AND TELECOMMUNICATIONS INDUSTRY STANDARDS AND PRACTICES CURRENTLY IN PLACE. C. UPON COMPLETION OF TESTING AND PROBLEM RESOLUTION,ALL CONNECTIONS MUST BE 100% ERROR FREE,WHERE"ERROR FREE"IS DEFINED TO MEAN THE ITEM MEETS ALL THE MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS AS PUBLISHED IN THEIR LATEST MANUFACTURING MANUALS FOR PROPER INSTALLATION AND TESTING. 3.20 TEST DOCUMENTS A. UPON COMPLETION OF TESTING,THE CONTRACTOR SHALL SUBMIT TO THE CONSTRUCTION MANAGER FOUR(4)FULL SETS OF TEST RESULTS. B. CABLE RECORDS MUST CONTAIN THE IDENTIFIER,CABLE TYPE,AND TERMINATION POSITIONS AT BOTH-ENDS,SPLICE INFORMATION AS WELL AS ANY DAMAGED PAIRS/CONDUCTORS. C. CONNECTING HARDWARE AND CONNECTING HARDWARE POSITION RECORDS MUST CONTAIN THE IDENTIFIER,TYPE,DAMAGED POSITION NUMBERS,AND REFERENCES TO THE CABLE IDENTIFIER ATTACHED TO IT. D. TEST DOCUMENTATION SHALL BE SUBMITTED IN ELECTRONIC FORM ON A CD-ROM,WITH THE APPROPRIATE SOFTWARE REQUIRED TO READ ALL TEST DATA. 3.21 ADJUSTING A. OCCUPANCY ADJUSTMENTS: WHEN REQUESTED WITHIN 12 MONTHS OF DATE OF SUBSTANTIAL REVISIONS`. COMPLETION,PROVIDE ON-SITE ASSISTANCE IN ADJUSTING SYSTEM TO SUIT ACTUAL OCCUPIED CONDITIONS AND TO OPTIMIZE PERFORMANCE OF THE INSTALLED EQUIPMENT.TASKS SHALL 'O INCLUDE,BUT ARE NOT LIMITED TO,THE FOLLOWING: ISSUED FOR BID-PERMIT 06.06.17 ei 1. CHECK CABLE CONNECTIONS. S 2. CHECK PROPER OPERATION OF CAMERAS AND LENSES. VERIFY OPERATION OF AUTO-IRIS LENSES AND ADJUST BACK-FOCUS AS NEEDED. V�, 3. ADJUST ALL PRESET POSITIONS;CONSULT OWNER'S PERSONNEL. N „ 4. RECOMMEND CHANGES TO CAMERAS,LENSES,AND ASSOCIATED EQUIPMENT TO IMPROVE V' OWNER'UTILIZATION OF VIDEO SURVEILLANCE SYSTEM. p N '; 5. PROVIDE A WRITTEN REPORT OF ADJUSTMENTS AND RECOMMENDATIONS. CL 3.22 TRAINING .,•"`. A. THE SECURITY CONTRACTOR SHALL PROVIDE FOUR(4)HOURS OF SYSTEM TRAINING TO THE LOCAL 8 , STAFF.THE TRAINING SHALL INCLUDE THE FOLLOWING: t% 1. ADMINISTRATION AND MONITORING REFRESHER COURSE FOR THE ACCESS CONTROL SYSTEM C•�9 2. REVIEW,PLAYBACK AND ADMINISTRATION OF THE CCTV SURVEILLANCE SYSTEM. 5 B. AFTER THE INITIAL TRAINING IS FINISHED,THE CONTRACTOR SHALL RETURN WITHIN ONE(1) g MONTH TO CONDUCT A REFRESHER TRAINING COURSE ON ALL SYSTEMS.THIS SESSION WILL COVER ANY ASPECTS THE END USER NEEDS ADDITIONAL INFORMATION AND ANSWERING -p s QUESTIONS REGARDING THE INITIAL USE OF THE SYSTEM.THE SECURITY CONTRACTOR SHALL c p ESTIMATE THIS TRAINING SESSION TO BE ONE(1)DAY IN LENGTH C. THE SECURITY CONTRACTOR SHALL SUBMIT A BRIEF TRAINING CONCEPT AND METHODOLOGY 11 PLAN TO THE SECURITY CONSULTANT FOR REVIEW AND APPROVAL NO LATER THAN TWO(2) DRAWING BY: WEEKS BEFORE THE TRAINING.THE DOCUMENT SHALL COVER THE FOLLOWING: DATE: Jun.. 1. COORDINATED TRAINING DATES AND DURATION WITH THE END USER 2. TOPICS THAT WILL BE COVERED FOR THE ACCESS CONTROL SYSTEM TRAINING a 06, 2017 4.0 3. TOPICS THAT WILL BE COVERED FOR THE CCTV SURVEILLANCE TRAINING JOB NUMBER: 02GPD--170493 4. REVIEW OF THE AS-BUILT DRAWINGS AND MANUALS WITH THE END USER CL 5. BRIEF DESCRIPTION OF THE TRAINING REFRESHER COURSE TITLE: .- 3.23 ACCEPTANCE 6 cl 6 ' A. UPON RECEIPT OF THE CONTRACTOR'S DOCUMENTATION OF CABLE TESTING,THE PHYSICAL SECURITY M OWNER/OWNER'S REPRESENTATIVE MAY REVIEW OR OBSERVE THE INSTALLATION AND REQUEST t7 1 RANDOM TESTS OF THE CABLES INSTALLED. THE NUMBER OF CABLES SO RANDOMLY TESTED S P E I FI A TI N S SHALL NOT EXCEED 5%OF THE TOTAL NUMBER OF CABLES INSTALLED. ONCE THE TESTING HAS BEEN COMPLETED AND CLIENT AND ITS REPRESENTATIVES ARE SATISFIED THAT ALL WORK IS IN .-0 g ACCORDANCE WITH THE CONTRACT DOCUMENTS,THE OWNER'S REPRESENTATIVE WILL NOTIFY SHEET NUMBER: w V THE SECURITY CONTRACTOR THROUGH THE CONSTRUCTION MANAGER IN WRITING. - d NA� r 3 .c p b S - 4 p ▪ u m COMMENTS: U U U o _ vii p c� ff -. _ ._.. ..-... . ._-. 10 CVS 1 Health , _-__ __. _ £ STORE . CORAM, INC. 7358 S W DURHAM RD. PORTLAND, OR 97224 ,o PROJECT TYPE: PHARMACY 4.. , , ,. I DEAL TYPE PPR O O CS PROJECT NU : 0106369 A> O ARCHITECT OF RECORD vr L CL-1 \ CONSULTANT: 1' i vw3Enc ineers+ Consultants • 155 SEAPORT BOULEVARD i KEYED NOTES. SEAPORT WEST, FLOOR 2 BOSTON, MA 02210 / ......... . P. 617.443.4950 • F. 617.443.4959 O SECURITY CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR, ELECTRICAL CONTRACTOR AND NPR DEELOpER• MANUFACTURER FOR INSTALLATION OF MAGNETIC LOCK, 1� • DOOR INTERLOCK AND POWER SUPPLY. THESE UNITS ARE PROVIDED BY THE NPR MANUFACTURER; INSTALLED BY THE ELECTRICIAN AND INTEGRATED WITH THE EXISTING SECURITY SYSTEM BY SECURITY CONTRACTOR. c I SEAL: E \ a REVISIONS: 3 ISSUED FOR BID-PERMIT 06.06.17 oi 01 Q I s d L U a> / EC9 O C a 1 DRAWING BY: E v DATE: June 06, 2017 m JOB NUMBER: 02GPD-170493 U a TITLE: oI- MPHYSICAL SECURITY o � CONSTRUCTION PLAN :- "' k SHEET NUMBER: c `o ~ AC CV CI) CD 1 C/ 4 N S - 3 /2 m i COMMENTS: ii II E ' a • E ALL DRAIN WIRES FROM SECURITY PANELS HOFFMAN 6 x 6 WIRE TROUGH - CATEGORY 6 SHALL TERMINATE qN GROUND BAR. SECURITY WITH COVER-NO KNOCK OUTS; PATCH CORD CATEGORY b CABLE GROUND BAR SHALL TERMINATE ON TGBB UTILIZE GREENLEE PUNCH SET 3/4"CONDUIT TO fTO IDE(BY OTHERS) FOR CUSTOM PENETRATIONS(BY NEAREST ACCESSIBLE BACK BOX CAM ACCESS SECURITY CONTRACTOR) CEILING(BY CEILING FURNISH&INSTALL PLENUM CABLE INTRUSION CONTROL • ELECTRICAL • SAFETY CHAIN/ 4111.1CVS PANEL CONTRACTOR) WIRE-ATrACHTO PANEL (QTY AS (TYPICAL) DROP CEILING auuQlNesrEE� IIII �� REQ. 3/4"CONDUIT FROM TILE/SHEET LAYOUT 2 GANG JUNCTION BOX 3/4"CONDUIT&LB BY FOR HARD CEILING APPLICATIONS ROCK CEILING •- CONDUIT STUB-UPS LEFT TO CEILING(BY ELECTRICAL �^ E FROM DOOR EAREST ACCESSIBLE ELECTRICAL CONTRACTOR TOGGLECLIPS 6" DOOR FRAME ,� CONTRACTOR) '• ' 1"CONDUIT f�ATEGORY 6 CABLEH Ith 47 IL BACK BOXI TO IDE(BY OTHERS) IF_ illsiTIRucrun CEILING CAMfACCESSIBLE HARD CEILING CEILING EXTEND � ADDITIONAL SUPPORT REQUIREMENTS mimmi ABOVE (TYPICAL) DROP CEILING PLYWggD FOUR PORT DATA OUTLET ' APS LPS (BY IT CONTRACTOR) FOR HARD CEILING APPLICATIONS i 2-INCH RIGID COUPLING WITH INTERIOR PARTITION II - STORE NUMBERHARD CEILING DETAIL CHASE NIPPLES ON BOTH SIDES(TYP) SECURELY FASTEN TO CEILING NEAREST WALL CEI LIN NEAREST WALL CORAM, INC. LOCK POWER SUPPLY(BY SECURITYCONTRACTOR-QUANTITIES AS IN __, 7358SW DURHAM RD. ACCORDANCE WITH / PORTLAND, OR 97224 i' \\\- REQUIRED) MANUFACTURER'S BACK BOXY my CATEGORY 6 CABLE BACK BOX CEILING MOUNTED ACCESS CONTROL AND ALARM GUIDELINES (TYPICAL) TO IDE ROOM (TYPICAL) CCN DATA PORT PHARMACY • PROVIDE QUAD RECEPTACLE MONITORING SYSTEM POWER DROP CEILING PATCH CORD (BY OTHERS) PROJECT "rte' BOX ON DEDICATED CIRCUITS SUPPLY(BY SECURITY CONTRACTOR- 1"CONDUIT TO NEAREST `, TM PPR ON UPS POWER(BY ELECTRICAL QUANTITIES AS REQUIRED) ACCESSIBLE PATHWAY ROVED i 11L CONTRACTOR) CAVITY WALL(E.G.,STUD) SOLID WALL • NOTE: FOR NO FINISHED CEILING APPLICATIONS CS PROJECT NUMBER0106369 NOTES: ELECTRICAL CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR AND SECURITY CONTRACTOR TO NOTES: H FURNISH AND SUPPLY ALL RELATED PATHWAYS AS INDICATED ON DRAWINGS AND FIRE ALARM RELAYS AS REQUIRED 1. COORDINATE MOUNTING LOCATION WITH OTHER TRADES TO ENSURE AN UNOBSCURED FIELD OF VIEW TO INTENDED (REFER TO FIRE ALARM DISCONNECT DIAGRAM ON SHEET PS-0i). 2. FURNISH AND INSTALL ALL REQUIRED CAMERA HOUSING MOUNTS AND ACCESSORIES. 1. COORDINATE MOUNTING LOCATION WITH OTHER TRADES TO INSURE AN UNOBSCURED FIELD OF VIEW. ARCHITECT OF RECORD 2. FURNISH AND INSTALL ALL REQUIRED CAMERA HOUSING MOUNTS AND ACCESSORIES. 4 JUNCTION BOX DETAILS 3 I SECURITY PANEL DETAIL 2 INDOOR SURFACE MOUNT CAMERA DETAIL 1 INDOOR CEILING MOUNT CAMERA DETAIL . 1-INCH CONDUIT(TYP) 4-11/16"X 4-11/16"X 2-1/8"JUNCTION 4-11/16"X 4-11/16"X 2-1/8"JUNCTION 1-INCH CONDUIT(TYP) 4-11/16"X 4-11/16"X 2-1/8"JUNCTION 4-11/16"X 4-11/16"X 2-1/8"JUNCTION BOX BY E.C.WITH DOUBLE-GANG MUD BOX BY E.C.WITH DOUBLE-GANG MUD BOX BY E.C.WITH DOUBLE-GANG MUD BOX BY E.C.WITH DOUBLE-GANG MUD TO NEAREST ACCESSIBLE S RING(LOCATE ON SECURE SIDE) RING(LOCATE ON SECURE SIDE) TO NEAREST ACCESSIBLE 1, RING(LOCATE ON SECURE SIDE) RING(LOCATE ON SECURE SIDE) APPROVED PATHWAY3/4-INCH CONDUIT(TYP) APPROVED PATHWAY El 1-INCH CONDUIT(TYP) ELECTRIC LOCKSET W/FREE EGRESS AND FULL TO NEAREST ACCESSIBLE TO NEAREST JB TO NEAREST ACCESSIBLE APPROVED PATHWAY APPROVED PATHWAY m DOOR FRAM MONITORING CAPABILITY: ACCESSIBLE APPROVED DOOR FRAME PATHWAY m -©-mom \ /ELECTRIC LOCKSET W/FREE EN m m I REQUEST-TO EXIT;DOOR DOOR 11111 EGRESS AND FULL DOOR DOOPOSITION STATUS;LATCHED ' 1 MONITORING CAPABILITY: I 1 I AND LOCK STATUS. ]p REQUEST-TO EXIT;DOOR (LOCATED ON SECURE SIDE) ML POSITION STATUS;LATCHED AND LOCK STATUS. (LOCATED ON SECURE SIDE) SINGLE GANG BOX AND 3/4-INCH CONDUIT TO mimi::= DOUBLEnIIINEAREST ACCESSIBLE e �� DOOR 7 - PATHWAY BY EC DOOR FRAM LOCK LATCHES \ \ 11 C/VI\SULTR ll■ , 4-11/16"X 4-11/16"X 2-1/8" 4-11/16"X 4-11/16"X 4-11/16"X 2-1/8" B ! a JUNCTION BOX BY E.C.WITH 4-11/16"X 2-1/8" JUNCTION BOX BY E.C.WITH DOO. SINGLE-GANG MUD RING(LOCATE JUNCTION BOX BY SINGLE-GANG MUD RING(LOCATE ON UN-SECURE SIDE) I E.C.WITH ON UN-SECURE SIDE) DDDR FRAM 1 SINGLE-GANG MUD UN-SECURE SIDE ELEVATION 1 RING(LOCATE ON UN-SECURE SIDE ELEVATION Engineers+ SECURE SIDE ELEVATION UN-SECURE SIDE ELEVATION I UN-SECURE SIDE) I ;I, IA®3 Consultants NOTES: NOTES: UN-SECURE SIDE ELEVATION SECURE SIDE ELEVATION 1. UNLESS OTHERWISE SPECIFIED ON ARCHITECTURAL DOOR SCHEDULE,ALL DOOR HARDWARE IS FURNISHED BY NOTES: 1. UNLESS OTHERWISE SPECIFIED ON ARCHITECTURAL DOOR SCHEDULE,ALL DOOR HARDWARE IS FURNISHED BY 4-11/16"X 4-11/16"X 2-1/8"JUNCTION BOX BY E.C.WITH OTHERS. OTHERS. 2.. ELECTRICAL CONTRACTOR SHALL PROVIDE JUNCTION BOX AND ALL CONDUITS AS INDICATED. 1. UNLESS OTHERWISE SPECIFIED ON ARCHITECTURAL DOOR SCHEDULE,ALL DOOR HARDWARE IS FURNISHED BY 2.. ELECTRICAL CONTRACTOR SHALL PROVIDE JUNCTION BOX AND ALL CONDUITS AS INDICATED. SINGLE-GANG MUD RING(LOCATE ON UN-SECURE SIDE) 155 SEAPORT BOULEVARD 3. REFER TO ARCHITECTURAL DRAWINGS FOR DEVICE HEIGHTS. OTHERS. 3. REFER TO ARCHITECTURAL DRAWINGS FOR DEVICE HEIGHTS. NOTES: 4. FIELD LOCATE DOOR POSITION SWITCH AND PREP DOOR/FRAME AS REQUIRED. 2.. ELECTRICAL CONTRACTOR SHALL PROVIDE JUNCTION BOX AND ALL CONDUITS AS INDICATED. 4. FIELD LOCATE DOOR POSITION SWITCH AND PREP DOOR/FRAME AS REQUIRED. SEAPORT WEST, FLOOR 2 5. UNLESS OTHERWISE INDICATED ALL LOCKS SHALL FAIL SECURE WITH FREE EGRESS. 3. REFER TO ARCHITECTURAL DRAWINGS FOR DEVICE HEIGHTS. 1. UNLESS OTHERWISE SPECIFIED ON ARCHITECTURAL DOOR SCHEDULE,ALL DOOR HARDWARE IS FURNISHED BY BOSTON, MA 02210 4. FIELD LOCATE DOOR POSITION SWITCH AND PREP DOOR/FRAME AS REQUIRED. OTHERS. P. 617.443.4950 . F. 617.443.4959 5. UNLESS OTHERWISE INDICATED ALL LOCKS SHALL FAIL SECURE WITH FREE EGRESS. 2.. ELECTRICAL CONTRACTOR SHALL PROVIDE JUNCTION BOX AND ALL CONDUITS AS INDICATED. 3. REFER TO ARCHITECTURAL DRAWINGS FOR DEVICE HEIGHTS. ;; 4. MAGNETIC LOCK SET SHALL BE EQUIPPED WITH DOOR POSITION MODULES,MAGNETIC BOND SENSOR, ANTI-TAMPER SWITCH AND DOOR STATUS SENSORS. ... ACCESS PORTAL WITH ELECTRIC STRIKE 6 ACCESS PORTAL WITH ELECTRIFIED LOCKSET PORTALWITH MAGNETIC LOCK SET [DLOPER: 8 ACCESS PORTAL WITH ELECTRIFIED LOCK SET 7 ( 5 ACCESS 4-11/16"X 4-11/16"X 2-1/8"JUNCTION . BOX BY E.C.WITH DOUBLE-GANG MUD 4"X 4"X 2"JUNCTION BOX BY 4-11/16"X 4-11/16"X 2-1/8" RING(LOCATE ON SECURE SIDE) 1-INCH CONDUIT(TYP) E.C.(LOCATE ON SECURE SIDE) JUNCTION BOX BY E.C.WITH 1-INCH CONDUIT{TYP} 1-INCH CONDUIT(TYP) DOUBLE-GANG MUD RING LEVEL SLAB (LOCATE ON SECURE SIDE) ABOVE ID TO NEAREST ACCESSIBLE APPROVED PATHWAY TO NEAREST ACCESSIBLE APPROVED PATHWAY �In TO NEAREST ACCESSIBLE APPROVED PATHWAY 'm 212 ■ FURNISH AND INSTALL PENDANT MOUNT KIT AS Ii' . , moi \ mo m f �o�m� �_� DOOR DOOR DOOR = REQUIRED TO SUIT FIELD CONDITIONS ELECTRIC CRASH BAR(ON ELECTRIC LOCKSET SECURE SIDE)W/FREE W/FREE EGRESS AND I! - , EGRESS AND FULL- FULL- Iii ULL- " MONITORING CAPABILITY CAPABILITY II PIPE EXTENSION-PROVIDE LENGTH AS REQUIRED (REQUEST-TO EXIT; I MONITORING ST-TO EXIT; TO PROVIDE AN UNOBSTRUCTED VIEW LATCHED AND LOCK LATCHED AND LOCK _ STATUS) STATUS) D 8 I ECB 1 I �� g ® R EQUIP CAMCLOSURE WITH PENDANT MOUNTVP DOOR FRAM ADAPTER AND CONCENTRIC REDUCERS AS DOOR FRAM /4-11/16"X 4-11/16"X DOOR FRAM /4i1/16"X 4-11/16"X REQUIRED MULLION MOUNT 2-1/8"JUNCTION BOX BY 2-1/8"JUNCTION 80X BY E.C.WITH SINGLE GANG E.C.WITH SINGLE-GANG MUD RING(LOCATE ON MUD RING(LOCATE ON SECURE SIDE) SECURE SIDE) 1 NOTES: SECURE SIDE ELEVATION UN-SECURE SIDE ELEVATION SECURE SIDE ELEVATION UN-SECURE SIDE ELEVATION SECURE SIDE ELEVATION UN-SECURE SIDE ELEVATION 1. FIELD COORDINATE MOUNTING HEIGHT OF CAMERA TO BE BELOW BOTTOM OF BEAM OR OTHER OBSTRUCTIONS AND COORDINATE LOCATION WITH OTHER TRADES TO ENSURE AN UNOBSCURED FIELD OF NOTES: V2. FURNISH AND INSTALL ALL REQUIRED CAMERA HOUSING MOUNTS AND ACCESSORIES. NOTES: NOTES: 1.UNLESS OTHERWISE SPECIFIED ON ARCHITECTURAL DOOR SCHEDULE,ALL DOOR HARDWARE IS FURNISHED BY OTHERS. 1. UNLESS OTHERWISE SPECIFIED ON ARCHITECTURAL DOOR SCHEDULE,ALL DOOR HARDWARE IS FURNISHED BY 1. UNLESS OTHERWISE SPECIFIED ON ARCHITECTURAL DOOR SCHEDULE,ALL DOOR HARDWARE IS FURNISHED BY 2. ELECTRICAL CONTRACTOR SHALL PROVIDE JUNCTION BOX AND ALL CONDUITS AS INDICATED. OTHERS. OTHERS. 3. REFER TO ARCHITECTURAL DRAWINGS FOR DEVICE HEIGHTS. 2.. ELECTRICAL CONTRACTOR SHALL PROVIDE JUNCTION BOX AND ALL CONDUITS AS INDICATED. 2.. ELECTRICAL CONTRACTOR SHALL PROVIDE JUNCTION BOX AND ALL CONDUITS AS INDICATED. 4. GEN DIA.HOLE CONTRACTOR OTED AT TOP LOCATE 4-INCHESDOOR CONTACT (LE., OORO POSITION ELECTRICALIIH) PREP DOOR WITH L 3. REFER TO ARCHITECTURAL DRAWINGS FOR DEVICE HEIGHTS. 3. REFER TO ARCHITECTURAL DRAWINGS FOR DEVICE HEIGHTS. REVISIONS: 4. MAGNETIC LOCK SET(BY OTHERS)SHALL BE EQUIPPED WITH DOOR POSITION MODULES,MAGNETIC BOND 4. FIELD LOCATE DOOR POSITION SWITCH AND PREP DOOR/FRAME AS REQUIRED. ASSURE DOOR CONTACT CONDUIT(S)PROPERLY ALIGN WITH OPENING AND THAT THE DOOR CONTACT CONDUIT al SENSOR,ANTI-TAMPER SWITCH AND DOOR STATUS SENSORS. 5. UNLESS OTHERWISE INDICATED ALL LOCKS SHALL FAIL SECURE WITH FREE EGRESS. DOES NOT EXCEED 1/4"BE;PW BOTTOM OF DOOR HEADER. EC SHALL FURNISH AND INSTALL BANG ON BUSHINGS ISSUED FOR BID-PERMIT 06.06.17 5. COORDINATE CONDUIT REQUIREMENTS WITH PLANS AND FIELD CONDITIONS{E.G.,MULLION READERS NOT AND PULL STRINGS FOR EACH DOOR CONTACT CONDUIT AS INDICATED ON PLANS AND DETAILS. ri INSTALLED AT ALL LOCATIONS). S. UNLESS OTHERWISE INDICATED ALL LOCKS SHALL FAIL SECURE WITH FREE EGRESS. Of titO I 12 - PENDANT MOUNT CAMERA DETAIL [ 11 I SINGLE DOOR WITH MAGNETIC LOCK SET 10 ACCESS PORTAL WITH ELECTRICONIC CRASH BAR RELEASE 9 ACCESS PORTAL WITH ELECTRIFIED LOCK SET Q a 0 1 a TO NEAREST ACCESSIBLE PATHWAY 4" "x2 LOCATE SECUREE SIDE 3/4-INCH CONDUIT(E.G.,CABLE TRAY) y ELECTRICAL CONTRACTOR SHALL JB PROVIDE 3/4-INCH CONDUIT AND FOR LOW VOLTAGE CABLING;ROUTE TO \ Al(93 EAREST ACCESSIBLE CEILING OR V.,.. IJI APPROVED LOW VOLTAGE PATHWAY. -DOOR FRAME 1 ... v 3/4-INCH CONDUITS&FITTINGS BY EC(REF) SECURELY FASTEN TO STRUCTURE IN DRAWING BY: ACCORDANCE WITH MANUFACTURERS INSTALLATION GUIDELINES. ` DATE: June 06, 2017 JOB NUMBER: 02GPD-170493 is illa d As NOTES: TIME:---DOOR ? ~ 1. FOLLOW MANUFACTURER INSTALLATION REQUIREMENTS TO ASSURE THAT PHYSICAL URITY M C?cl THE MOUNTING HEIGHT OF INTERCOM SYSTEM IS ADACOMPLIANT.2. SECURELY FASTEN TO STRUCTURE PER MANUFACTURER INSTALLATION DETAILS REQUIREMENTS. SMir 5. COORD N 3. UNIT IS PREWIRED FOR CONDUIT FOR 120V AC POWER. ELECTRICAL •Yid: DOOR POSITION RELAY. PI O 04 CONTRACTOR SHALL PROVIDE TWO(2)3/4-INCH CONDUITS. ROUTE ONE 4 «° COORDINATE N �d ', ■ INSTALLATION WITH DOOR SHEET NUMBER: CONDUIT TO PANEL AND ONE CONDUIT TO FIRST FLOOR FACILITY ROOM =�, t0 (WHERE A CONCEALED PATHWAY IS NOT AVAILABLE). SECURITY •.,I++-'. NOTES: HARDWARE SUPPLIER AND .� W Q CONTRACTOR SHALL COORDINATE WITH GC AND ELECTRICAL CONTRACTOR NOTES: r7 �� DOOR MOTOR S C c 0- FOR EXACT MOUNTING HEIGHT/LOCATION OF CONDUITS. 1. COORDINATE MOUNTING HEIGHT WITH OTHER TRADES TO ENSURE AN UNOBSCURED FIELD OF VIEW TO CONTROLLER FOR ALARM 0 N 4. COODINATE AS REQUIRED WITH ELECTRICAL AND IT CONTRACTORS TO INTENDED TARGET. 1. DOOR HARDWARE BY OTHERS. INPUTS AS SPECIFIED - /1 n y;� PROVIDE SURGE AND LIGHTNING PROTECTION AS SPECIFIED BY 2. FURNISH AND INSTALL ALL REQUIRED CAMERA HOUSING MOUNTS AND ASSEMBLIES. 2. ELECTRICAL CONTRACTOR SHALL PROVIDE JUNCTION BOX AND ALL CONDUITS AS INDICATED. �. - G + MANUFACTURER AND ALL APPLICABLE CODES. 3. FURNISH AND INSTALL HEAVY DUTY DOOR CONTACT(S). 4. WIRE ONE DOOR CONTACT TO LEN EL PANEL AND ONE DOOR CONTACT TO BOSCH INTRUSION PANEL. 1COMMENTS: 11 11 E 16 EMERGENCY CALL STATION PEDESTAL DETAIL 15 EXTERIOR CAMERA WALL MOUNT DETAIL ( 14 OVERHEAD DOOR WITH POSITION SENSOR/RELAY-TYPE C m6 o ., - , . GENERAL NOTES TELECOMMUNICATIONS ABBREVIATIONS (WHERE APPLICABLE) TELECOMMUNICATIONS SYMBOLS 1.THE SCOPE OF WORK SHALL INCLUDE PROVIDING ALL WORK INDICATED,UNLESS AC ALTERNATING CURRENT EX EXTENSION PL PRIVATE LINES SYMBOL DESCRIPTION SPECIFICALLY INDICATED AS WORK OF OTHER SECTIONS,OWNER OR EXISTING TO REMAIN. A/D ANALOG TO DIGITAL CONVERSION F FOR FACILITY USE PLT PLANT STANDARD TWO PORT WALL MOUNTED INFORMATION OUTLET PROVIDE COORDINATION WITH ALL TRADES.SCOPE OF WORK IS INDICATED ON THE CONTRACT DOCUMENTS INCLUDING THE DRAWINGS AND THE SPECIFICATIONS,WHICH ARE ACLG ABOVE CEILING FAX FAX MACHINE OUTLET PM PHASE MODULATION (2)4-PAIR CATEGORY 6 CABLES(REFER TO SPECIFICATION FOR COMPLIMENTARY.WORK INDICATED IN ANY CONTRACT DOCUMENT SHALL BE CONSIDERED ACO ANALOG CENTRAL OFFICE FCC FEDERAL COMMUNICATIONS COMMISSION P01 POINT OF INTERFACE TYPE/COLOR)TERMINATED ON(2)8-CONDUCTOR CATEGORY 6 SNAP-IN PART OF THE SCOPE OF WORK.IN GENERAL,WORK REQUIREMENTS ARE NOT INDICATED IN CONNECTORS BOTH DOCUMENTS.WHERE DOCUMENTS CONFLICT WITHIN THEMSELVES OR WITH CODES ACC ACCESS TELEPHONE FD FLOOR DISTRIBUTOR POTS PLAIN OLD TELEPHONE SERVICE Ir."'" '" *"1 'n".. "'"..."'""""...1CliS I AND REGULATIONS,PROVIDE THE GREATER QUANTITY,HIGHER QUALITY AND FOLLOW THE ADA AMERICANS WITH DISABILITIES ACT FDM FREQUENCY-DIVISION MULTIPLEXING PR PAIR !! STANDARD(X)PORT WALL MOUNTED INFORMATION OUTLET STRICTER REQUIREMENTS. ADO AUXILIARY DISCONNECT OUTLET FDR FEEDER PS PROJECTION SCREEN - 2. DRAWINGS ARE DIAGRAMMATIC ONLY. EXACT LOCATION,MOUNTING HEIGHTS AND AER AERIAL FEXT FAR END CROSSTALK PT POKE THRU WITH 2 HOUR FIRE/SMOKE RATED PENETRATION (X=NUMBER OF CABLES)4-PAIR CATEGORY 6 CABLES(REFER TO - Health _ . ROUTING SHALL BE COORDINATED WITH ARCHITECT, GENERAL CONTRACTOR,OTHER TRADES SPECIFICATION FOR TYPE/COLOR)TERMINATED ON(X=NUMBER OF EQUIPMENT REQUIREMENTS AND FIELD CONDITIONS. AFF ABOVE FINISH FLOOR FF FLUSH FLOOR BOX WITH FIRE/SMOKE RATED PENETRATION PTSS PASSIVE TRANSMISSION SUB-SYSTEM CABLES)8-CONDUCTOR CATEGORY 6 SNAP-IN CONNECTORS. AIA AMERICAN INSTITUTE OF ARCHITECTS FN OUTLET FOR MODULAR FURNITURE,SEE DETAILS PVC POLYVINYL CHLORIDE STANDARD TWO PORT FURNITURE MOUNTED INFORMATION OUTLET 3.IN GENERAL OUTLET BOXES AND RACEWAYS WITH PULL STRINGS EXCEPT INNER DUCT SHALL RCDD REGISTERED COMMUNICATIONS DISTRIBUTION DESIGNER BE PROVIDED BY ELECTRICAL CONTRACTOR. PROVIDE UNDER THIS SECTION ALL AM AMPLITUDE MODULATION FOTP FIBER OPTIC TEST PROCEDURE RE RE-USE EXISTING CONDUIT&BACKBOX. PROVIDE (2)4-PAIR CATEGORY 6 CABLES(REFER TO SPECIFICATION FOR TELECOMMUNICATIONS EQUIPMENT,CABLING,DEVICES,FACE PLATES,ETC.FOR A COMPLETE ANSI AMERICAN NATIONAL STANDARDS INSTITUTE FOTS FIBER OPTICS TRANSMISSION SYSTEM CABLING AT LOCATIONS AS SHOWN V TYPE/COLOR)TERMINATED ON(2)8-CONDUCTOR CATEGORY 6 SNAP-IN INSTALLED AND PERFORMANCE TESTED SYSTEM,PROVIDE OUTLET BOXES&RACEWAYS AS AR AREA OF RESCUE TELEPHONE FREQ FREQUENCY CONNECTORS REQUIRED WHERE NOT PROVIDED BY ELECTRICAL CONTRACTOR OR AS INDICATED ON REA RURAL ELECTRIFICATION AGENCY I �{� DRAWINGS. ASCII AMERICAN STANDARD CODE FOR INFORMATION INTERCHANGE FTP FOIL TWISTED-PAIR REF REFERENCE STANDARD (X)PORT FURNITURE MOUNTED INFORMATION OUTLET STORE NUMBER 1; • 4.WHEREVER CONDUIT OR CABLE TRAY IS NOT PROVIDED,CABLING SHALL UTILIZE A J-HOOK ATM ASYNCHRONOUS TRANSFER MODE GA GAUGE REP REPAIR F(X) (X)4-PAIR CATEGORY 6 CABLES(REFER TO SPECIFICATION FOR CORAM, INC.INCC SYSTEM FOR DISTRIBUTION THROUGHOUT THE FACILITY. AWG AMERICAN WIRE GAUGE GEC GROUNDING ELECTRODE CONDUCTOR RFI RADIO FREQUENCY INTERFERENCE TYPE/COLOR)TERMINATED ON(X= NUMBER OF CABLES)8-CONDUCTOR B BURIED GHz GIGAHERTZ 5.COORDINATE CABLE INSTALLATIONS WITH ALL OTHER TRADES IN ORDER TO NOT DAMAGE RFQ REQUEST FOR QUOTE CATEGORY 6 SNAP-IN CONNECTORS7358 S W DURHAM RD. THE CABLES DURING CONSTRUCTION, ANY CABLE THAT IS DAMAGED DURING CONSTRUCTION BBISDN BROAD BAND INTEGRATED SERVICES DIGITAL NETWORK GND GROUND RMS RACK MOUNT SPACE CARE TV ONE PORT INFORMATION OUTLET SHALL NOT BE REPAIRED. IT SHALL BE COMPLETELY REPLACED AT NO ADDITIONAL COST TO BD BUILDING DISTRIBUTOR HC HORIZONTAL CROSS-CONNECT PORTLAND, OR 97224 THE OWNER,ARCHITECT OR ENGINEER. RUS RURAL UTILITIES SERVICES CARE TV (1)4-PAIR CATEGORY 6 CABLE(REFER TO SPECIFICATION FOR TYPE/COLOR) PROJECT Myr, PHARMACY BEE BUILDING ENTRANCE FACILITY he HANDSET COMBINATION(SINGLE-LINE TELEPHONE) 5B SMARTBOARD LOCATION(WALL MOUNTED) rfll./YGb1 1 IfG ffVYllirlLl TERMINATED ON(1)8-CONDUCTOR SNAP-IN CONNECTORS.COORDINATE 6.TEST ALL EQUIPMENT AND SYSTEMS INSTALLED TO CERTIFY COMPLIANCE WITH DRAWINGS, BER BIT ERROR RATE hck HANDSET COMBINATION;KEY(SIX-BUTTON TELEPHONE) ScTP SCREENED TWISTED-PAIR WITH AV CONTRACTOR OR ARCHITECT FOR LOCATION. I DEAL TYPE: MR SPECIFICATIONS,CODES,STANDARDS,LOCAL AUTHORITIES AND REGULATIONS. INCLUDE BIC BUILDING INDUSTRY CONSULTANT HF HIGH FREQUENCY SDN SWITCHED DIGITAL NETWORK TV ONE PORT INFORMATION OUTLET - LABOR AND COSTS FOR REVIEWS,TESTING,APPROVALS AND CERTIFICATIONS. BICSI BUILDING INDUSTRY CONSULTING SERVICE INTERNATIONAL HH HANDHOLE SI SYSTEM INTERNATIONAL TV (1)4-PAIR CATEGORY 6 CABLE{REFER TO SPECIFICATION FOR TYPE/COLOR) CS PROJECT NUMBER: 0106369 7.PROVIDE SLEEVES WITH SMOKE AND FIRE SEALS AT ALL PENETRATIONS THROUGH FIRE BRISDN BASIC RATE INTEGRATED SERVICES DIGITAL NETWORK HVAC HEATING,VENTILATION,AND AIR-CONDITIONING SMPS SWITCHED MODE POWER SUPPLY RATED ASSEMBLIES OR FLOORS OR FULL HEIGHT{SLAB TO SLAB)WALLS. SNR SIGNAL-TO-NOISE RATIO TERMINATED ON(1)8-CONDUCTOR SNAP-IN CONNECTORS.COORDINATE BTU BRITISH THERMAL UNIT Hz HERTZ WITH AV CONTRACTOR OR ARCHITECT FOR LOCATION.(1)HDMI FEMALE TO 8.PROVIDE CONDUIT SLEEVES WITH INSULATED BUSHINGS AT ALL PENETRATIONS THROUGH C MOUNTED ABOVE COUNTER-COORDINATE EXACT IC INTERMEDIATE CROSS-CONNECT SP SERVICE PROVIDER FEMALE 19 PIN KEYSTONE JACK WHITE.COORDINATE WITH AV BUILDING ELEMENTS SUCH AS WALLS,SOFFITS,ETC.THAT DO NOT REQUIRE FIRE OR SMOKE MOUNTING HEIGHT WITH ARCHITECTURAL DRAWINGS SPC STORED PROGRAM CONTROL CONTRACTOR OR ARCHITECT FOR LOCATION. ARCHITECT OF RECORD SEALS. ICEA INSULATED CABLE ENGINEERS ASSOCIATION CA CABLE IDC INSULATION DISPLACEMENT CONNECTION SPD SURGE PROTECTING DEVICE CEILING MOUNTED DATA DROP 9.WORK SHALL BE RECESSED INTO WALLS,AND INSTALLED ABOVE HUNG CEILINGS,UNLESS CATV CABLE TELEVISION SPG SINGLE-POINT GROUND IDE INTERMEDIATE DISTRIBUTION FRAME OTHERWISE INDICATED.ALL WORK SHALL BE INSTALLED CONCEALED WHENEVER POSSIBLE. CBC COUPLED BONDING CONDUCTORIEEE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS,INC. STA STATION ® (1)4-PAIR CATEGORY 6 CABLE(REFER TO SPECIFICATION FOR TYPE/COLOR) TERMINATED ON(1)8-CONDUCTOR SNAP-IN CONNECTORS.COORDINATE 10.IN GENERAL,GROUNDING&BONDING SYSTEM IS PROVIDED BY ELECTRICAL CONTRACTOR. CCITT CONSULTATIVE COMMITTEE INT INTERCOM TELEPHONE STP SHIELDED TWISTED-PAIR WITH AV CONTRACTOR OR ARCHITECT FOR LOCATION.(1)HDMI FEMALE APPROPRIATE GROUNDING&BONDING CONNECTIONS WITHIN MDF/IDF'S TO THE CD CAMPUS DISTRIBUTOR ISDN INTEGRATED SERVICES DIGITAL NETWORK SW STATION WIRE TO FEMALE 19 PIN KEYSTONE JACK WHITE.COORDINATE WITH AV TELECOMMUNICATIONS GROUNDING BUSBAR SHALL BE INCLUDED UNDER THIS CONTRACT AS CDD♦ COPPER DISTRIBUTED DATA INTERFACE INTERNATIONAL STANDARDS ORGANIZATION SWB SWITCHBOARD _. CONTRACTOR OR ARCHITECT FOR LOCATION. INDICATED IN DRAWINGS&SPECIFICATIONS. SIX AUDIO VISUAL OUTLET CDF CENTRAL DISTRIBUTION FRAME 1W INSIDE WIRING(CABLE) SYS SYSTEM AV 11.CABLING IS SHOWN ON DRAWINGS ONLY FOR SPECIFIC ROUTES OR SPECIAL CDO COMMUNITY DIAL OFFICE CONDITIONS. kHz KILOHERTZ TB TACKBOARD V (3)4-PAIR CATEGORY 6 CABLE(REFER TO SPECIFICATION FOR TYPE/COLOR) CKT CIRCUIT KTS KEY TELEPHONE SERVICE TBB TELECOMMUNICATIONS BONDING BACKBONE TERMINATED ON(3)8-CONDUCTOR SNAP-IN CONNECTORS.(1)HDMI 12.CONTRACTOR SHALL PROVIDE MATERIALS AND EQUIPMENT THAT IS NRTL LISTED FOR USE IN CFC COMMUNICATIONS FLAT CABLE KWH KILOWATT-HOURS TBBC TELECOMMUNICATIONS BACKBONE BONDING CONDUCTOR FEMALE TO FEMALE 19 PIN KEYSTONE JACK WHITE.COORDINATE WITH AV ANY SPACE ABOVE CEILINGS THAT ARE RETURN AIR PLENUMS. CONTRACTOR OR ARCHITECT FOR LOCATION. CLT CLOSET LAN LOCAL AREA NETWORK TBBIBC TELECOMMUNICATIONS BONDING BACKBONE CO CENTRAL OFFICE AV AV FLOOR BOX OUTLET LASER LIGHT AMPLIFICATION BY STIMULATED EMISSION OF RADIATION INTERCONNECTING BONDING CONDUCTOR CODEC CODER DECODER LATA LOCAL ACCESS TRANSPORT AREA TC TELECOMMUNICATIONS CLOSET ® (4)4-PAIR CATEGORY 6 CABLES(REFER TO SPECIFICATION FOR COE CENTRAL OFFICE EQUIPMENT Ibf POUNDS,FORCE TD TEACHERS DATA TELECOMMUNICATIONS OUTLET, TYPE/COLOR)TERMINATED ON(4)8-CONDUCTOR CATEGORY 6 SNAP-IN COT CENTRAL OFFICE TERMINAL LBO LINE BUILD OUT REFER TO DETAILS FOR EXACT DESCRIPTION. CONNECTORS,(1)HDMI FEMALE TO FEMALE 19 PIN KEYSTONE JACK WHITE. CPC CUSTOMER PREMISES COMMUNICATIONS LEC LOCAL EXCHANGE CARRIER TOM TIME-DIVISION MULTIPLEXING MOUNTED IN FLOOR BOX(FLOOR BOX BY EC). FLOOR BOX OUTLET _. _. .... :..... ... CPE CUSTOMER PREMISES EQUIPMENT LED LIGHT-EMMITTING DIODE TEBC TELECOMMUNICATIONS EQUIPMENT BONDING CONDUCTOR FB(X) CP CEILING MOUNTED PRESENTATION LOCATION FOR PROJECTORS locap LOW-CAPACITANCE,LOW-LOSS PAIRED CABLE TEL TELEPHONE ®1 (X)4-PAIR CATEGORY 6 CABLES(REFER TO SPECIFICATION FOR CPU CENTRAL PROCESSING UNIT M MOUNTED IN MILL WORK. COORDINATE WITH TELCO TELEPHONE COMPANY TYPE/COLOR)TERMINATED ON(X)8-CONDUCTOR CATEGORY 6 SNAP-IN CONSULTANT• CSA CANADIAN STANDARDS ASSOCIATION ARCHITECTURAL DRAWINGS TERM TERMINAL CONNECTORS.MOUNTED IN FLOOR BOX(FLOOR BOX BY EC). CSMA/CA CARRIER SENSE MULTIPLE ACCESS/COLLISION AVOIDANCE MB MARKERBOARD TGB TELECOMMUNICATIONS GROUNDING BULBAR w WALL PHONE INFORMATION OUTLET CSMA/CD CARRIER SENSE MULTIPLE ACCESS/COLLISION DETECTION MC MAIN CROSS-CONNECT THD THIRD HARMONIC DISTORTION D/A DIGITAL TO ANALOG CONVERSION MEC MASSACHUSETTS ELECTRIC CODE TIA TELECOMMUNICATIONS INDUSTRIES ASSOCIATION • TERMINATED(1)4 NIR CAON(1) -CABLE CTO(REFRRNO SNAP-IN CONNECTORNFAND TYPE/COLO D E ON(1)8-CONDUCTOR MOUNTED DAF DEDICATED ACCESS FACILITY MDF MAIN DISTRIBUTION FRAME TM TRANSFORMER MANHOLE/VAULT IN STAINLESS STEEL WALL PHONE FACEPLATE. ppr 1 dB DECIBEL M/G MOTOR/GENERATOR SET TMGB TELECOMMUNICATIONS MAIN GROUNDING BULBAR WALL PHONE ANALOG INFORMATION OUTLET Encs I I y�Iee S+ DC DIRECT CURRENT MH MANHOLE TO TELECOMMUNICATIONS OUTLET WAConsultants DCE DATA CIRCUIT-TERMINATING EQUIPMENT modern MODULATOR DEMODULATOR TP TRANSFORMER PAD (1)4-PAIR CATEGORY 6 CABLE(REFER TO SPECIFICATION FOR TYPE/COLOR) TERMINATED ON(1)8-CONDUCTOR SNAP-IN CONNECTOR AND MOUNTED DCO DIGITAL CENTRAL OFFICE MPOP MINIMUM POINT OF PRESENCE TPDDI TWISTED PAIR DISTRIBUTED DATA INTERFACE IN STAINLESS STEEL WALL PHONE FACEPLATE. ALLENTEL 8 AT630A WALL DO DISTRIBUTION DESIGNER MTT MAIN TELEPHONE TERMINAL TPPMD TWISTED PAIR PHYSICAL MEDIA DEPENDENT PHONE. DEMARCDEMARCATION POINT N NEWTON TR TAMPER RESISTANT WIRELESS ACCESS POINT 155 SEAPORT BOULEVARD DGM DATA GRADE MEDIUM NEC NATIONAL ELECTRICAL CODE TSB TELECOMMUNICATIONS SYSTEM BULLETIN SEAPORT WEST, FLOOR 2 DIST DISTRICT NESC NATIONAL ELECTRICAL SAFETY CODE TT TELEPHONE TERMINAL AP (1)4-PAIR CATEGORY 6 CABLE(REFER TO SPECIFICATION FOR TYPE/COLOR) BOSTON, MA 02210 DTE DATA TERMINAL EQUIPMENT NEXT NEAR END CROSSWALK TTB TELEPHONE TERMINAL BOARD 17 TERMINATED ON(1)8-CONDUCTOR SNAP-IN CONNECTOR AND MOUNTED P. 617.443.4950 • F. 617.443.4959 DW DISTRIBUTION WIRE NI NETWORK INTERFACE TTY TEXT TELEPHONES IN SURFACE MOUNT BOX.LEAVE 20 FT OF SLACK COIL DRESSED AT BOX. EF ENTRANCE FACILITY N.I.C. NOT IN CONTRACT AIPHONE OUTLET TVSS TRANSIENT VOLTAGE SURGE SUPPRESSER EIA ELECTRONICS INDUSTRIES ASSOCIATION NID NETWORK INTERFACE DEVICE IC TW WIREWAY TRANSFORMER (1)4-PAIR CATEGORY 6 CABLE{REFER TO SPECIFICATION FOR TYPE/COLOR) DEVELOPER ELEV ELEVATOR TELEPHONE NRTL NATIONALLY RECOGNIZED TESTING LABORATORY EMC ELECTROMAGNETIC COMPATIBILITY OPD OVER CURRENT PROTECTION DEVICE TYP TYPICAL TERMINATED ON(1)8-CONDUCTOR SNAP-IN CONNECTORS GREEN IN EMIR EMERGENCY TELEPHONE OPE OUTSIDE PLANT ENGINEER UG UNDERGROUND COLOR.DROP55HALL RUN TO MDF SECURITY CABINET. UL UNDERWRITERS LABORATORIES,INC. CEILING SPEAKER EMI ELECTROMAGNETIC INTERFERENCE OSHA OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION UON UNLESS OTHERWISE NOTED OSP OUTSIDE PLANT EMR ELECTROMAGNETIC RADIATION UPS UNINTERRUPTIBLE POWER SUPPLY O CEILING SPEAKER.CABLE WITH AWG 18/2 SHIELDED WIRE.SEE EMT ELECTRIC METALLIC TUBING PABX PRIVATE AUTOMATIC BRANCH EXCHANGE SPECIFICATIONS FOR SPEAKER TAP LEVEL.SPEAKERS MAY REQUIRE 1 ETV EDUCATIONAL TELEVISION PAM PULSE AMPLITUDE MODULATION UTP UNSHIELDED TWISTED-PAIR ADJUSTMENT DEPENDING ON LOCATION. E/W EQUIPPED WITH PAY PAY TELEPHONE VCSEL VERTICAL CAVITY SURFACE MOUNTING LASER HORN SPEAKER W WALL MOUNTED TELEPHONE DEVICE ESS ELECTRONIC SWITCHING SYSTEM PBX PRIVATE BRANCH EXCHANGE WA WORK AREA _ D HORN SPEAKER.CABLE WITH AWG 16/2 SHIELDED WIRE.ARROW DEPICTS EXCH EXCHANGE PCM PULSE CODE MODULATION DIRECTION OF SOUND.SPEAKERS ARE TAPPED AT 7.5 WATTS TYPICALLY. ,• PED PEDESTAL MOUNTED WITH TWO HOUR FIRE/SMOKE WP WATERPROOF OUTLET SPEAKERS MAY REQUIRE ADJUSTMENT DEPENDING ON LOCATION. RATED PENETRATION SECURITY CAMERA OUTLET ...,<, CAM (1)4-PAIR CATEGORY 6 CABLE(REFER TO SPECIFICATION FOR TYPE/COLOR) TERMINATED ON(1)8-CONDUCTOR SNAP-IN CONNECTOR AND MOUNTED IN ) IN SURFACE MOUNT BOX.LEAVE 20 FT OF SLACK COIL DRESSED AT BOX. . TIME CLOCK OUTLET El (1)4-PAIR CATEGORY 6 CABLE(REFER TO SPECIFICATION FOR TYPE/COLOR) TERMINATED ON(1)8-CONDUCTOR SNAP-IN CONNECTOR.COORDINATE1 i EXACT MOUNTING HEIGHT WITH ARCHITECT. WALL MOUNTED FURNITURE IN-FEED LOCATION INSTALLED BY ELECTRICAL CONTRACTOR,FOR USE BY tl TELECOMMUNICATIONS CONTRACTOR. SHOWN FOR REFERENCE ONLY. COORDINATE FINAL PULL POINT IN FIELD WITH ELECTRICAL CONTRACTOR/ARCHITECT. TELECOMMUNICATIONS CONTRACTOR TO PROVIDE BLACK SPIRAL PROTECTIVE WRAP OR APPROVED EQUAL METHOD TO DRESS CABLES IN A CLEAN FASHION AT IN-FEED LOCATION. FURNITURE IN-FEED LOCATION -(TELE-POLE) INSTALLED BY ELECTRICAL CONTRACTOR,FOR USE BY 'Al'! TELECOMMUNICATIONS CONTRACTOR. SHOWN FOR REFERENCE REVISIONS: LAM. ONLY. COORDINATE FINAL PULL POINT IN FIELD WITH ELECTRICAL CONTRACTOR/ARCHITECT. ISSUED FOR BID—PERMIT 06.06.17 TELECOMMUNICATIONS CONTRACTOR TO PROVIDE BLACK SPIRAL PROTECTIVE WRAP OR APPROVED EQUAL METHOD TO DRESS A L IN A CLEAN FASHION AT IN-FEED LOCATION. rte) a) ml- Q - WIRE MESH STYLE CABLE TRAY TRAPEZE HUNG IN CEILING. 1 0a N O I // /J/T J MOLD PLUG DIVIDED PROVIDED BY OTHERS I O C GENERAL SYMBOLS i W SYMBOL DESCRIPTION / v 0 KEY NOTE SYMBOL,REFER TO NOTE AS INDICATED. c V 00 DRAWING BY: a. B SECTION IDENTIFIER,INDICATING SECTION"B"ON DRAWING T0.3. E T0.3 o DATE: June 06, 2017 C T® DETAIL IDENTIFIER,INDICATING DETAIL NO.2 ON DRAWING T0.3. JOB NUMBER: 02GPD-1 70493 el I TITLE: a 4 TELECOMMUNICATIONS DRAWING LIST diCi TELECOMMUNICATIONS DRAWING NUMBER DRAWING TITLE NI T-0.1 TELECOMMUNICATIONS LEGEND LEGEND r ,, 1-2.1 TELECOMMUNICATIONS SPECIFICATIONS NT-2.2 TELECOMMUNICATIONSSPECIFICATIONS SHEET NUMBER: c c a NT-2.3 TELECOMMUNICATIONS SPECIFICATIONS 0.4 c...., T _ 0 1 v1 o 1-3.1 TELECOMMUNICATIONS CONSTRUCTION PLAN o 8- CEJ T-4.1 _ TELECOMMUNICATIONS DETAILS 1 OF 3 • II -.-• COMMENTS: m T-4.2 TELECOMMUNICATIONS DETAILS 2 OF 3 11 II E - - - - ii 1 y 5 T-4.3 TELECOMMUNICATIONS DETAILS 3 OF 3 ✓ a -.._.2..._.,.,-:..... . PART 1- GENERAL 3. PROVIDE AND INSTALL ALL WORK AREA DROPS(AS TERMINATED IN EITHER WALL 1.10 INFORMATION REQUESTS 7. ANSI/TIAJEIA-607,COMMERCIAL BUILDING GROUNDING AND BONDING REQUIREMENTS 3. INSTALLATION AND TESTING OF FACTORY MANUFACTURED FIBER OPTIC CABLING AND OUTLETS OR FURNITURE OUTLETS)IN THE CLIENT SPACE,AS REFLECTED ON THE A. CONTRACTORS SHALL SUBMIT REQUESTS FOR INFORMATION IN ACCORDANCE VtfITH THE FOR TELECOMMUNICATIONS CONNECTORS DRAWINGS. GENERAL REQUIREMENTS AS SPECIFIED IN SECTION 01000. 8. ANSI/TIA/EIA-942,TELECOMMUNICATIONS INFRASTRUCTURE STANDARD FOR IDES 4. BONDING AND GROUNDING OF RACKS,CABINETS,LADDER RACK/CABLE TRAY AND 1.D1 RELATED DQCUMENTS 4. PROVIDE AND INSTALL ALL SECURITY CAMERA AREA DROPS{AS TERMINATED WORK 1.11 BIDDER'S CONFERENCE CABLE SHIELDS , 9. ASTM A513-SPECIFICATION FOR ELECTRIC-RESISTANCE-WELDED CARBON AND ALLOY G A. DRAWINGS,GENERAL CONDITIONS OF THE CONTRACT AND DIVISION 1 GENERAL AREA BOXES)IN THE CLIENT SPACE,AS REFLECTED ON THE DRAWINGS. A. REFER TO CONSTRUCTION MANAGER'S REQUIREMENTS FOR BIDDER'S CONFERENCE STEEL MECHANICAL TUBING 5. TESTING CONDUCTORS FOR TRANSMISSION IMPAIRMENTS REQUIREMENTS APPLY TO THE WORK OF THIS SECTION.EXAMINE REFERENCED DOCUMENTS INFORMATION. FOR REQUIREMENTS AFFECTING THE WORK. 5. PROVIDE AND ROUGH INSTALL ALL SECURITY CABLING.CONTRACTOR SHALL PULL 10. AT&T OUTSIDE PLANT HANDBOOK 6. TESTING CONDUCTOR INSULATION B. EXAMINE ALL OTHER SECTIONS OF THE SPECIFICATIONS AND ALL OTHER DRAWINGS FOR CABLES TO LOCATION TO BE INSTALLED AND TERMINATED BY SECURITY CONTRACTOR. 1.12 RIGHT OF RESECTION a REQUIREMENTS WHICH AFFECT WORK UNDER TW5 SECTION,WHETHER OR NOT SUCH WORK 11. BICSI DISTRIBUTION METHODS AND BEST PRACTICES 7. INSTALLATION,FUSION SPLICING,AND TERMINATION OF OPTICAL FIBER CABLING 6. PROVIDE ALL NON-SPECIFIED MISCELLANEOUS HARDWARE(I.E.,NUTS,BOLTS,VELCRO A- CLIENT AND CONSTRUCTION MANAGER RESERVE TME RIGHT TO ACCEPT OR REJECT ANY OR IS SPECIFICALLY MENTIONED IN THIS SECTION, TIES,ETC.) ALL BIDS AND TO ENTER INTO DISCUSSION AND!OR NEGOTIATIONS WITH ANY OR MORE THAN 12. BICSI CUSTOMER-OWNED OUTSIDE PLANT DESIGN MANUAL 8. TESTING AND VERIFICATION OF OPTICAL FIBER TRANSMISSION CHARACTERISTICS WITH 1.02 SUMMARY DESCRIPTION ONE QUALIFIED SUPPLIER AT THE SAME TIME OR ANY TIME,SHOULD SUCH ACTION BE IN THE A POWER METER AND LIGHT SOURCE 7. PROVIDE ALL COPPER PATCH CORDS AND CROSS-CONNECTS,IN THE MDF AS SPECIFIED BEST INTERESTS OF CLIENT. 13. CVS IT DISTRIBUTION METHODS AND BEST PRACTICES A. CVS HEALTH CORAM,HEREAFTER REFERRED TO AS THE"CLIENT",IS BUILDING OUTA IN THIS DOCUMENT.PROVIDE COPPER PATCH CORDS AT WORKSTATIONS IN LENGTHS B. NEITHER THE CONSTRUCTION MANAGER NOR CLIENT IS UNDER ANY OBLIGATION TO AWARD A 9. TELEPHONE AND DATA INDUSTRY CABLE INSTALLATION STANDARDS AND NEGATIVE PRESSURE ROOM IN A LEASED FACILITY AT 73585W DURHAM RD.,PORTLAND,OR 14. TELCORDIA SR-1421,BLUE BOOK-MANUAL OF CONSTRUCTION PROCEDURES: 97224 AND QUANTITIES AS SPECIFIED IN THIS DOCUMENT. CONTRACT ON THE BASIS OF THIS BID, MANUFACTURER'S INSTRUCTIONS WILL BE USED FOR IN-PROCESS QUALITY CONTROL p a B. THIS SPECIFICATION CONTAINS THE REQUIREMENTS FOR THE INSTALLATION OF STRUCTURED 8. PROVIDE LABELING AND DOCUMENTATION OF ALL CABLES AND HARDWARE INSTALLED 1.13 RIGHT OF INCORPORATION 1.21 BASIS OF DESIGN AND INTENT OF DRAWINGS AND FINAL ACCEPTANCE OF THE WORK INSTALLATION € 6 CABLING SYSTEMS AS WELL AS THE TELECOMMUNICATION CLOSET(MDF)INFRASTRUCTURE UNDER THIS SPECIFICATION. COORDINATE LABELING PLAN CLOSELY WITH CONSULTANT A. IT IS UNDERSTOOD THAT BIDDER'S RESPONSE DOES NOT CONSTITUTE AN OFFER ON THE A. IT IS THE INTENT OF THE DRAWINGS AND SPECIFICATIONS TO PROVIDE A COMPLETE 10. NETWORK CABINET,RELAY RACK AND FRAME INSTALLATION CABLING FOR THE AFOREMENTIONED LOCATION. ALL QUOTATIONS MUST ENSURE THAT ANY [WB ENGINEERS I CONSULTANTS]AND OWNER. TERMS STATED IN THE PROPOSAL,AND THAT SHOULD A CONTRACT BE AWARDED,CLIENT AND WORKABLE IT NETWORK INFRASTRUCTURE CABLING SYSTEM READY FOR THE OWNER'S USE. INABILITY TO COMPLY WITH THESE REQUIREMENTS IS CLEARLY STATED IN THE QUOTATION THE CONSTRUCTION MANAGER MAY,AT THEIR OPTION,INCORPORATE ALL OR ANY PART OF ANY ITEM NOT SPECIFICALLY SHOWN ON THE DRAWINGS OR CALLED FOR IN THE 11. CONDUIT AND LADDER RACK RUNWAY AND CABLE TRAY SYSTEM INSTALLATION E SUBMISSION. 9. TEST/CERTIFY ALL CABLING AND TERMINATION HARDWARE INSTALLED AS REQUIRED IN YOUR RESPONSE IN THE CONTRACT. SPECIFICATION,BUT NORMALLY REQUIRED FOR A COMPLETE SYSTEM,IS TO BE CONSIDERED 1,26 WORK IN HARMONY a C. THE CLIENT HEREBY INVITES YOU(HEREAFTER REFERRED TO AS THE"BIDDER"OR THIS SPECIFICATION,INCLUDING PREPARATION AND SUBMISSION OF TESTING REPORTS 1.14 CONFIDENTIALITY OF BIDDER INFORMATION A PART OF THE CONTRACT. • E "SUBCONTRACTOR")TO SUBMIT A PROPOSAL TO FURNISH AND INSTALL THE WORK SPECIFIED DESCRIBED HEREIN- B. THE LOCATIONS OF STRUCTURAL AND ARCHITECTURAL FEATURES,EXISTING SLEEVES,FLOOR A. THE SUBCONTRACTOR AND ITS EMPLOYEES SHALL WORK IN HARMONY WITH ALL OTHER CORAM, INC" 1 IN THIS DOCUMENT AND RELATED MATERIALS. PRIOR TO SUBMITTING A PROPOSAL,THE A- YOU ARE BEING REQUESTED TO PROVIDE TO CLIENT DATA REGARDING YOUR ORGANIZATION SLOTS,TERMINATIONS AND CROSS CONNECTS,PANELS,RACKS,CABINETS,GROUND BUSES, SUBCONTRACTORS,CONTRACTORS AND EMPLOYEES WORKING ON THE SITE. y BIDDER SHOULD CONSIDER THE SCOPE OF WORK,THE QAIQC REQUIREMENTS,THE TIME 10. INSTALL ALL REQUIRED CATEGORY 6 PLENUM CABLES TO ALL CAMERAS. IN-CEILING AND YOUR PRODUCTS AND SERVICES. AND OTHER EQUIPMENT INDICATED ON THE DRAWINGS ARE APPROXIMATE- THE B. REFER TO CONSTRUCTION MANAGER'S REQUIREMENTS FOR ALL WORK IN HARMONY 7358 S W DURHAM RD. I FRAME,AND THE COMMITMENT OF RESOURCES REQUIRED TO RESPOND IN A PROFESSIONAL CAMERAS SHALL BE TREATED JUST LIKE ANY OTHER DATA RUN AND SHALL NOT BE RUN B. IN THE EVENT ANY DATA SUPPLIED TO CLIENT IS CONFIDENTIAL,PLEASE NOTE SUCH SUBCONTRACTOR SHALL VERIFY THE EXISTENCE,LOCATIONS.AND SUITABILITY OF ALL SUCH GUIDELINES. Rn eND OR 97224 F MANNER. AS A GROUP AND SHALL NOT BE TERMINATED SEQUENTIALLY OR EXPLICITLY ON CONFIDENTIALITY IN A SEPARATE LETTER. ITEMS,AND SHALL PRESENT,WITH BID RESPONSE,REQUIRED MODIFICATIONS TO CONTRACT 1.27 PROJECT MEETINGS RO ,LA D. THE SYSTEMS PROPOSED BY THE BIDDER MUST MEET ALL OF THE SPECIFICATIONS DEDICATED PATCH PANELS;THE IDEA BEING,THAT CAMERAS SHOULD FALL RANDOMLY C. CLIENT AGREES THAT FOR A PERIOD OF ONE(1)YEAR IT SHALL TAKE THE SAME STEPS TO DOCUMENTS NECESSARY TO COMPLETE THIS WORK. y� DESCRIBED HEREIN.EACH COMPONENT IN THE PROPOSED SYSTEM SHALL BE CONSIDERED ON PATCH PANELS TO ASSURE A FAIRLY EVEN(ALBEIT RANDOM)DISTRIBUTION ACROSS PROTECT THE CONFIDENTIALITY OF SUCH INFORMATION,AS IT TAKES IN CONNECTION WITH 1.22 GENERAL ABBREVIATIONS A. REFER TO CONSTRUCTION MANAGER'S REQUIREMENTS FOR WEEKLY OR SEMI-WEEKLY j TI E: �� FOR ITS INDIVIDUAL MERITS AND FOR ITS CONTRIBUTION TO THE ENTIRE SYSTEM. THE BIDDER MULTIPLE PATCH PANELS. THIS APPROACH WILL ASSURE THAT CAMERAS DO NOT LAND INFORMATION ABOUT ITSELF. HOWEVER,IN NO EVENT,SHALL INFORMATION ABOUT YOU OR PROJECT MEETING REQUIREMENTS AND DAILY FOREMAN'S COORDINATION MEETING �y�, MUST INCLUDE SPECIFICATION SHEETS,AND OTHER LITERATURE AND DOCUMENTS TO YOUR PRODUCTS BE DEEMED CONFIDENTIAL IF: A. (ANSI)AMERICAN NATIONAL STANDARDS INSTITUTE REQUIREMENTS- a � 1,P IfR ON A SINGLE BLADE AND ARE DIVERSELY SPREAD ACROSS ACTIVE EQUIPMENT AND SUPPORT THE EQUIPMENT CHOICES IN THE BID PROPOSAL. 1. ALREADY KNOWN TO CLIENT,ALREADY IN THE PUBLIC DOMAIN,OR DISCLOSED TO B. (EIA)ELECTRONIC INDUSTRIES ASSOCIATION 1.28 COORDINATION WITH OWNER =' SUBNETS. FURNISH EACH CAMERA DROP WITH A 20-FOOT SERVICE LOOP COILED AT 1.03 BASIS OF DESIGN AND INTENT OF DRAWINGS THE ACCESS POINT END OF THE RUN. TERMINATE CAMERA CABLING AS INDICATED ON CLIENT BY A THIRD PARTY HAVING A RIGHT TO MAKE SUCH DISCLOSURE. C. (ETL)ELECTRICAL TESTING LABORATORIES,INC. A- THE SUBCONTRACTOR WILL COOPERATE AND COORDINATE ALL ACTIVITIES WITH THE 0106369 A. IT IS THE INTENT OF THE DRAWINGS AND SPECIFICATIONS TO PROVIDE A COMPLETE DRAWING. 2. IN NO EVENT,WITHOUT THE PRIOR WRITTEN CONSENT OF CLIENT,SHOULD YOU REVEAL D. (FCC)FEDERAL COMMUNICATIONS COMMISSION CONSTRUCTION MANAGER,OWNER AND THE 1T CONSULTANT. • E. (IEEE)INSTITUTE OF ELECTRICAL&ELECTRONICS ENGINEERS - .. I END-TO-END STRUCTURED CABLING SYSTEMS)FOR WORK STATIONS AND DEDICATED TO CLIENT ANY DATA THAT YOU DEEM A TRADE SECRET,BECAUSE CLIENT'S OBLIGATION 1.29 SUBMITTALS INFRASTRUCTURE CABLING SYSTEMS SUPPORTING AN IDF READY FOR THE CLIENTS USE. ANY C. PREPARATION AND SUBMISSION OF PRODUCT DATA,SWOP DRAWINGS,AS BUILT DRAVINGS F. (NEC)NATIONAL ELECTRICAL CODE AND CABLE DOCUMENTATION AS DESCRIBED HEREIN OF CONFIDENTIALITY AS SET OUT IN THIS PARAGRAPH MAY NOT BE SUFFICIENT TO A. EACH SUBMITTAL SHALL CONTAIN JOB TITLE AND REFERENCE TO THE APPLICABLE DRAWING ITEM NOT SPECIFICALLY SHOWN ON THE DRAWINGS OR CALLED FOR IN THIS BOOK G. (NEPA}NATIONAL FIRE PROTECTION ASSOCIATION ' SPECIFICATION,BUT NORMALLY REQUIRED FOR A COMPLETE SYSTEM(S),IS TO BE D. QUANTITIES OF ALL€TENS REFLECTED ON DRAWINGS SHALL SUPERSEDE QUANTITIES LISTED PROTECT THE SAME. H. (OSHA)OCCUPATIONAL SAFETY&HEALTH ADMINISTRATION AND SPECIFICATION ARTICLE. ARCHITECT OF RECORD HEREIN. IN ANY CASE SUFFICIENT QUANTITIES OF ALL COMPONENTS TO PROPERLY INSTALL B. SUBMITTAL LIST t t CONSIDERED A PART OF THE CONTRACT. 1.15 USE OF CLIENT'S NAME I- (TCO)TEMPORARY CERTIFICATE OF OCCUPANCY g AND TERMINATE ALL CABLING SPECIFIED SHALL BE INCLUDED WITHIN THE CONTRACT SUM. B. THE LOCATIONS OF STRUCTURAL AND ARCHlTEGTURAL FEATURES,EXISTING SLEEVES,FLOOR 1. SUBCONTRACTOR SHALL SUBMIT WITH BID FOR REVIEW AND ACCEPTANCE A LIST OF SLOTS,TERMINATIONS AND CROSS CONNECTS,PANELS,RACKS,CABINETS,GROUND BUSES, E. SUBCONTRACTOR IS TO VERIFY ALL FOOTAGE AND CABLE DISTANCES USING FLOOR PLANS A. IN CONNECTION WITH THIS PROJECT THE BIDDER SHALL NOT USE THE NAME OF CLIENT,OR J. (TWA)TELECOMMUNICATION INDUSTRIES ASSOCIATION AND OTHER EQUIPMENT INDICATED E THE DRAWINGS ARE APPROXIMATE. THE SUBCO NT AND VIA SITE SURVEYS. SUBCONTRACTOR IS RESPONSIBLE FOR ANY COPPER ANY OF ITS SUBSIDIARIES OR AFFILIATES,IN ANY PUBLICATIONS OR PUBLIC RELATIONS K. (UL)UNDERWRITERS'LABORATORIES,INC. ALL MATERIAL AND EQUIPMENT MANUFACTURERS WHOSE PRODUCTS ARE PROPOSED. SUBCONTRACTOR SHALL VERIFY THE EXISTENCE,LOCATIONS,AND SUITABILITY OF ALL SUCH DATA RUN EXCEEDING BUM(295FT.)AND ANY SUCH OVER LENGTH RUN SHALL BE REPLACED ANNOUNCEMENTS WITHOUT THE WRITTEN CONSENT OF CLIENT,PRIOR TO SUCH PUBLICATION i.23 GENERAL DEFINITIONS 2. ONLY SPECIFIED MANUFACTURERS SHALL APPEAR ON THE SUBMITTAL UST. THE AT SUBCONTRACTOR EXPENSE.REFER TO CONSTRUCTION MANAGER'S REQUIREMENTS FOR OR ANNOUNCEMENT. COMPLETE SUBMITTAL LIST MUST BE REVIEWED AND ACCEPTED BY THE IT CONSULTANT ITEMS,AND SHALL PRESENT,WITH BID RESPONSE,REQUIRED MODIFICATIONS TO CONTRACT A- "AS bIRECTED":MEANS AS INSTRUCTED BY THE QYVNERICONSUL7ANT OR GENERAL DOCUMENTS NECESSARY TO COMPLETE THIS WORK. ARRANGING SITE SURVEY AND BIDDERS CONFERENCE INFORMATION- B, CLIENT RESERVES THE RIGHT TO REVIEW AND APPROVE ALL PRESS RELATED COPY ANp MAY PRIOR TO SUBMITTAL OF THE MANUFACTURER'S PRODUCT DATA. NO SHOP DRAWINGS c 1.04 COORDINATION F. EXAMINE ALL OTHER SECTIONS OF THE SPECIFICATIONS AND ALL OTHER DRAWINGS FOR WITHHOLD CONSENT FOR RELEASE OF SUCH COPY,WITH OR WITHOUT CAUSE,AT ITS SOLE CONTRACTOR.. WILL BE PROCESSED WITHOUT AN ACCEPTED SUBMITTAL LIST. REQUIREMENTS WHICH AFFECT WORK UNDER THIS SECTION,WHETHER OR NOT SUCH WORK DISCRETION. B. "BACKBONE":A FACILITY(E.G.,PATHWAY,CABLE,OR CONDUCTORS)BETWEEN PULS,MDFS, A. CAREFULLY CHECK SPACE REQUIREMENTS AND THE PHYSICAL CONFINES OF THE AREAS OF IS SPECIFICALLY MENTIONED IN THIS SECTION. 1.16 COMPLIANCE WITH LAWS IDES,AND/OR PBX ROOMS WITHIN OR BETWEEN BUILDINGS. C. MANUFACTURER'S PRODUCT DATA C. "BIDDER"-SYSTEMS SUBCONTRACTOR SUBMITTING A BID RESPONSE TO THESE g WORK TO ENSURE THAT ALL MATERIAL GAN BE INSTALLED INA CODE COMPLIANT MANNER IN 1,07 SCHEDULE 1. WITHIN THREE(3)DAYS OF EXECUTED CONTRACT SUBMIT MANUFACTURER'S PRODUCT THE SPACES ALLOTTED THERETO,INCLUDING ALL WALL-MOUNTED PANELS,POWER SUPPLIES, A. BY SUBMITTING A SIGNED PROPOSAL,THE BIDDER ACKNOWLEDGES AND ATTESTS THAT THE SPECIFICATIONS. DATA FOR ALL PRODUCTS AND EQUIPMENT IN THE SUBMITTAL LIST- & CONDUITS,ETC.... A. SEE CONSTRUCTION MANAGER'S INSTRUCTIONS FOR INFORMATION DETAILING THE PROJECT PROPOSED WORK,SERVICES,AND MATERIALS CONFORM TO AND COMPLY WITH ALL D. CHANNELS:SEPARATE PARALLEL SIGNAL PATHS,FROM SOURCES TO LOUDSPEAKERS OR B. COORDINATE WITH OTHER TRADES THE LOCATIONS OF DEVICES,MACHINERY AND EQUIPMENT SCHEDULE. APPLICABLE FEDERAL,STATE,COUNTY,AND CITY LAWS,CODES,AND REGULATIONS. LOUDSPEAKER ZONES,WITH SEPARATE AMPLIFICATION AND SWITCHING THAT PERMIT 2. MANUFACTURER'S PRODUCT DATA SHALL CONSIST OF ILLUSTRATIONS,CATALOG CUTS, SO THAT PROPER REQUIRED SLACK LOOPS WHILE ADHERING TO THE REQUIRED CABLE B. SUBCONTRACTOR SHALL SUBMIT WITH HIS PROPOSAL MANPOWER LOADING,SEQUENCING, 1.17 EVALUATION FACTORS SELECTION BETWEEN PATHS FOR SPEAKER ALTERNATIVE PROGRAM SIGNALS. STANDARD SCHEDULES,PERFORMANCE CHARTS,INSTRUCTIONS,BROCHURES, LENGTH LIMITATIONS ARE MAINTAINED. MATERIALS STAGING REQUIREMENTS,WORKING DAYS,SHIFT TIME,WEEKEND TIME,AND E. COMPLETE("DONE").MEANS 100°/OFF ALL WORK,TESTING,SUBMITTALS AND SIGNOFFS ARE DIAGRAMS,AND OTHER INFORMATION FURNISHED BY THE SUBCONTRACTOR TO k OTHER REQUIREMENTS AS MAY BE REQUIRED TO CONFORM WITH PROJECT SCHEDULE. A. FACTORS USED IN EVALUATING THE BID RESPONSE SHALL INCLUDE,BUT ARE NOT LIMITED TO, FINISHED TO THE SATISFACTORY OF THE OWNER AND CONSULTANT. ILLUSTRATE A MATERIAL,PRODUCT.OR SYSTEM FOR SOME PORTION OF THE WORK. C. TRANSMIT TO CONSTRUCTION MANAGER ALL INFORMATION NECESSARY FOR ANY WORK THE FOLLOWING CRITERIA: REQUIRED BY OTHER TRADES AND/OR EQUIPMENT SUBCONTRACTORS IN A TIMELY MANNER C. SUBCONTRACTOR SHALL PROVIDE EVIDENCE OF ABILITY TO STAFF THE PROJECT WITH F. "CONSOLIDATION POINT(CP)":A LOCATION FOR INTERCONNECTION BETWEEN CABLES. 1. THE ORGANIZATION SELECTED MUST DEMONSTRATE A STRONG COMMITMENT TO 3. THE IDENTIFICATION OF ITEMS SUBMITTED IN CATALOG,PAMPHLET,ETC.SHALL BE TO ENSURE THAT THE PROJECT SCHEDULE IS MAINTAINED AND THAT ALL TRAINED PERSONNEL IN SUFFICIENT NUMBERS AND WITH SUFFICIENT SUPERINTENDENCE TO G. "DEMARCATION POINT":A POINT AT WHICH TWO SERVICES MAY INTERFACE AND IDENTIFY THE , TRADES/SUBCONTRACTORS HAVE THE INFORMATION NECESSARY TO PROPERLY INSTALL ALL PERFORM THE WORK WITHIN THE TIMEFRAMES IN THE PROJECT SCHEDULE. CLIENT IN TERMS OF SERVICE,TECHNICAL SUPPORT,AND LONG-TERM COMMITMENT. DIVISION OF RESPONSIBILITY. IT IS A POINT WHERE OPERATIONAL CONTROL OR OWNERSHIP CLEARLY MADE IN INK. DATA OFA GENERAL NATURE WILL NOT BE ACCEPTED. NECESSARY CONNECTIONS AND EQUIPMENT. D. WORK NECESSARY TO BE PERFORMED AFTER REGULAR WORKING HOURS,ON SUNDAYS,OR 2. THE ORGANIZATION SELECTED MUST HAVE PROVEN EXPERIENCE IN THE INSTALLATION CHANGES. AN EXAMPLE WWOULD BE THE INTERFACE BETWEEN A PUBLIC NETWORK AND A D. SHOP DRAWINGS D. PROVIDE TIMELY NOTICE TO IDENTIFY ALL ITEMS OF WORK THAT REQUIRE ACCESS SO THAT LEGAL HOLIDAYS,SHALL BE PERFORMED WITHOUT ADDITIONAL EXPENSE TO CLIENT. CLIENT OF TELECOMMUNICATION AND IT NETWORK INFRASTRUCTURE CABLING SYSTEMS, PRIVATE NETWORK. 1. SUBMIT WITHIN 15 DAYS OF EXECUTED CONTRACT SYSTEM DIAGRAMS WHICH SHALL THE CONSTRUCTION MANAGER MAY ARRANGE FOR SUCH ACCESS WITHIN THE TIME WILL NOT HONOR SUBSEQUENT REQUESTS FOR PREMIUM LABOR RATES OR OVERTIME. THE ASSOCIATED COMPONENTS AND HARDWARE. H. "ENTRANCE POINT":THE POINT OF EMERGENCE OF TELECOMMUNICATIONS CONDUCTORS CONTAIN SUFFICIENT DETAIL TO DESCRIBE THE WORK COMPLETELY AND CLEARLY. - - - -"- ��� � - CONSTRAINTS OF THE PROJECT SCHEDULE. SUBCONTRACTOR WILL ASSUME THE RISK OF PROPER SCHEDULING TO MEET ANY IMPOSED THROUGH AN EXTERIOR WALL,A CONCRETE FLOOR SLAB,OR FROM A RIGID METAL CONDUIT INFORMATION INCLUDED SHALL BE SUFFICIENT TO DESCRIBE LOCATION OF FIELD ■ 1.05 CONTRACTUAL REQUIREMENTS DEADLINES. 3. THE ORGANIZATION SELECTED MUST EXHIBIT A TRACK RECORD OF SATISFACTORY OR INTERMEDIATE METAL CONDUIT. CONSULTANT■ E. THE SUBCONTRACTOR IS RESPONSIBLE TO ORDER AND STAGE ALL MATERIALS DELIVERY IN A CUSTOMER RELATIONS IN FIELD INSTALLATION,SERVICE,PROJECT MANAGEMENT,AND I. "EQUIVALENT","SIMILAR",OR"EQUAL°-OF BASE BID MANUFACTURER,EQUAL IN MATERIALS, CONNECTIONS,TERMINAL POINTS,INTERCONNECTION OF COMPONENTS,CONTROL A. SUBCONTRACTOR IS TO PROVIDE MATERIALS,EQUIPMENT AND SERVICES,AND PERFORM ALL TIMELY MANNER;INCLUDING ANY CHARGES TO EXPEDITE DELIVERY OF MATERIALS AND ENGINEERING. SIZE,COLOR,DESIGN.AND EFFICIENCY OF SPECIFIED PRODUCT,CONFORMING TO THE PANEL LOCATIONS,RACK/CABINET LAYOUT AND CABLE ROUTING. NECESSARY PROCEDURES REQUIRED FOR THE INSTALLATION OFA COMPLETE AND PREMIUM TIME ASSOCIATED WITH MAINTAINING THE PROJECT SCHEDULE FOR THE SCOPE OF SPECIFIED BASE BID MANUFACTURER. NOTE:MUST BE APPROVED BY WB ENGINEERING,INC. E- PRESALE STATEMENT OF WARRANTY .. OPERATIONAL TELECOMMUNICATIONS SYSTEMS AS INDICATED ON THE DRAWINGS OR WORK DEFINED HEREIN. 4. THE ORGANIZATION SELECTED MUST HAVE THE PROJECT MANAGEMENT CAPABILITIES PRIOR TO BID ACCEPTANCE. THE PROPOSED SUBSTITUTION MUST,IN EVERY TECHNICAL 1. THE BID PACKAGE SHALL BE ACCOMPANIED BY A PRESALE WARRANTY COMMITMENT SPECIFIED HEREIN. 1.08 BID FORMS TO COST EFFECTIVELY AND RAPIDLY RESPOND TO FIELD CONDITIONS SUCH AS SENSE,PROVIDE THE SAME OR BETTER CAPABILITY AND FUNCTIONALITY AS THE SPECIFIED B. IT IS THE INTENT OF THIS SPECIFICATION THAT ALL ITEMS UNDER THESE SECTIONS BE ADDITIONS,DELETIONS,AND TIME FRAME CHANGES THROUGH THE RE-SCHEDULING OF ITEM. SUCH REQUESTS FOR APPROVAL SHALL BE SUBMITTED IN ACCORDANCE WITH THE BINDING THE AWARDED CONTRACTOR AND MANUFACTURER TO CLIENT AN EXTENDED ENGINEERED,ASSEMBLED,INSTALLED AND MAINTAINED BY,AND UNDER THE FULL A. CERTIFICATION OF COMPLIANCE MANPOWER,SUPPLYING OF EQUIPMENT AND MODIFICATION OF SHOP DRAWINGS. PROVISIONS OF THIS SPECIFICATION AND MUST BE OBTAINED WITHIN THE TIME FRAMES WARRANTY PACKAGE OF NOT LESS THAN 25 YEARS IN LENGTH. RESPONSIBILITY OF SUBCONTRACTOR,WHETHER THESE PROCESSES ARE ACTUALLY 1. SUBCONTRACTOR BIDS ARE TO BE ACCOMPANIED BY A COPY OF THE MANUFACTURER'S OUTLINED. 2- WITHIN 24 HOURS AFTER NOTIFICATION,THE SUBCONTRACTOR SHALL CORRECT ANY Engineers+ PERFORMED BY SUBCONTRACTOR OR NOT. WARRANTY STATING THE DURATION AND OUTLINING ALL TERMS AND CONDITIONS. 5- THE PROPOSAL PRICING MUST REFLECT A THOROUGH UNDERSTANDING OF THE JOB J. "EXPOSED":MEANS NOT INSTALLED UNDERGROUND OR"CONCEALED"AS DEFINED ABOVE. ' G. SUBCONTRACTOR RESPONSIBILITIE S THROUGH ACCURATE DRAWING"TAKE-OFFS",MANPOWER AND MATERIALS SCHEDULING, DEFICIENCIES THAT OCCUR DURING THE GUARANTEE PERIOD AT NOADDITIONAL COST Consu(tants B. BIDDER EXPERIENCE AND QUALIFICATIONS K. "IDE": INTERMEDIATE DISTRIBUTION FRAME(LE,TELECOMMUNICATIONS ROOM) TO OWNER,ALL TO THE SATISFACTION OF CLIENT,CONSTRUCTION MANAGER AND IT 1. COMPLY WITH ALL PROJECT SAFETY REQUIREMENTS. AND PROJECT MANAGEMENT APPROACH. THE OVERALL COMPETITIVENESS OF L. "INDICATED','SHOWN",OR"NOTED": AS INDICATED,SHOWN,OR AS NOTED ON DRAWINGS OR 1. THE FOLLOWING ITEMS ARE THE MINIMUM WORK EXPERIENCE REQUIRED FOR PROPOSED PRICING WILL BE WEIGHTED HEAVILY. SPECIFICATIONS. CONSULTANT. 2. SUBCONTRACTOR SHALL GENERATE ALL SHOP DRAWINGS AND INFORMATION FOR THE CONSIDERATION OF CABLING SUBCONTRACTOR BID SUBMITTAL. COMPLETE INSTALLATION AND WIRING OF SPECIFIED SYSTEMS. SUBCONTRACTOR 6. THE PROFESSIONALISM OF THE PROPOSAL AND MARKETING/TECHNICAL STAFF M. "INSTALL": IS USED TO DESCRIBE OPERATIONS AT PROJECT SITE(AND/OR MOVE FROM F. RECORD DRAWINGS , SHALL PROVIDE ON-GOING SUPERVISION AND COORDINATION DURING THE 2. THE SUBCONTRACTOR SHALL BE FULLY CONVERSANT AND CAPABLE IN THE CABLING OF INVOLVED WILL PROVIDE VALUABLE INSIGHT INTO EACH ORGANIZATION'S ABILITY AND PROPERTY LINE)INCLUDING THE ACTUAL UNLOADING,UNPACKING,RIGGING IN PLACE, 1- DURING CONSTRUCTION,THE SUBCONTRACTOR SHALL MAINTAIN A COPY OF ALL 155 SEAPORT BOULEVARD OUTSIDE PLANT AND PREMISE FIBER OPTIC CABLING INSTALLATIONS TO INCLUDE THE ASSEMBLY,ERECTION,PLACING,ANCHORING,APPLYING,WORKING TO DIMENSION,FINISHING, SPECIFICATIONS AND A COMPLETE SET OF THE CONSTRUCTION DRAWINGS ON THE JOB IMPLEMENTATION PHASE,AS REQUIRED- USE OF AN OPTICAL TIME DOMAIN REFLECTOMETER(OTDR),OPTICAL LOSS TEST SET WILLINGNESS TO SATISFY THE COMPLEX ANp CHANGING NEEDS OF CLIENT. CURING,PROTECTING,CLEANING,AND SIMILAR OPERATIONS. 1T MEANS THE INSTALLATION IS SITE,MAKING NOTATIONS AND UPDATES THEREON,AS REQUIRED TO PROVIDE AN SEAPORT WEST, FLOOR 2 3. SUBCONTRACTOR SHALL COORDINATE WITH THE MAIN CONTRACTOR,ELECTRICAL COLTS),AND FUSION SPLICING EQUIPMENT AND ASSOCIATED FIBER OPTIC TROUBLE 1.18 TERMS AND CONDITIONS TO BE COMPLETE AND READY FOR REGULAR OPERATION,EXCEPT AS OTHERWISE NOTED. ACCURATE RECORD OF ALL INSTALLATIONS PURSUANT TO THE ISSUE IFAS-BUILT BOSTON, MA 02210 CONTRACTOR,SAFETY SYSTEMS CONTRACTOR OR OTHER CONTRACTORS ON ALL SHOOTING EQUIPMENT. A. ALL BIDS MUST BE SUBMITTED IN ACCORDANCE WITH THE SPECIFICATIONS AND INFORMATION N. "INSTALLER": AN"INSTALLER"IS THE CONTRACTOR OR AN ENTITY ENGAGED BY THE DRAWINGS. P. 617.443.4950• F. 617.443.4959 RELATED ISSUES AND CONCERNS. FOR CLARIFICATION PURPOSES,ALL ISSUES AND CONTAINED HEREIN,AS WELL AS WITH SUPPLEMENTAL REQUIREMENTS AND ANY ADDENDA CONTRACTOR,EITHER AS AN EMPLOYEE,SUBCONTRACTOR,OR SUB-SUBCONTRACTOR FOR e CONCERNS SHOULD BE DOCUMENTED AND SUBMITTED TO THE CONSULTANT AND 3. THE SUBCONTRACTOR SHALL BE FULLY CONVERSANT AND CAPABLE IN THE CABLING OF PERFORMANCE OFA PARTICULAR CONSTRUCTION ACTIVITY,INCLUDING INSTALLATION, G. AS-BUILT DRAWINGS ISSUED BY THE CONSTRUCTION MANAGER. ERECTION,APPLICATION,AND SIMILAR OPERATIONS. INSTALLERS ARE REQUIRED TO BE OWNER. LOW VOLTAGE APPLICATIONS SUCH AS,BUT NOT LIMITED TO DATA,VOICE AND VIDEO 1. UPON ACCEPTANCE OF THE WORK,SUBCONTRACTOR SHALL SUBMIT TO THE B THE BIDDER AGREES THAT ITS PROPOSAL SHALL BE DEEMED AN OFFER TO CLIENT THROUGH E XPERIENCED IN THE OPERATIONS THEY ARE ENGAGED TO PERFORM- "` NETWORK SYSTEMS,AND INSTALLATION OF SINGLE AND MULTIMODE FIBER;CATEGORY CLIENT/CONSULTANT THREE FULL SETS OF AS-BUILT DRAWINGS-AS-BUILT DOCUMENTS 4. SUBCONTRACTOR SHALL ATTEND ALL JOB MEETINGS AS REQUIRED. THE CONSTRUCTION MANAGER,AND THAT IT WILL REMAIN VALID FORA PERIOD OF NO LESS O. "LACE OR WRAP": A TERM USED TO DESCRIBE THE PLACEMENT OF CABLE ON CABLE TRAY, c DEVELOPER■ 3,CATEGORY 5E,CATEGORY 6,CATEGORY 6A UTP CABLES;AND COAXIAL CABLE. SHALL INCLUDE EACH DRAWING INCLUDED IN THE BID SET AS WELL AS ANY ADDITIONAL THAN 120 DAYS FROM RECEIPT. BIDDER AGREES THAT,IF SELECTED,ALL LABOR AND LADDER RACK,VERTICAL MANAGEMENT AND HORIZONTAL STRAYN RELIEF TO ENSURE A CLEAN ■ 5- SUBCONTRACTOR MUST PROVIDE APPROPRIATE FIRE STOP PROVISIONS FOR ALL 4. THE SUBCONTRACTOR SHALL,ATA MINIMUM,POSSESS THE FOLLOWING MATERIAL PRICING CONTAINED IN SUCH PROPOSAL SHALL,TOGETHER WITH THIS DOCUMENT, FLOW OF CABLES FROM PATCH PANEL OR TERMINATION UNIT TO THE WORK AREA OUTLET. DRAWINGS OR SKETCHES ISSUED DURING THE COURSE OF CONSTRUCTION- CABLES THAT PASS THROUGH FIRE-RATED WALLS,FLOORS,RISERS AND CEILINGS. FORM THE BASIS OF A CONTRACT. QUALIFICATIONS: P. "MDF": MAIN DISTRIBUTION FRAME(I.E.,MAIN TELECOMMUNICATIONS ROOM) 2. AS-BUILT DRAWINGS WILL REFLECT THE ACTUAL MANNER AND CONDITIONS OF HOWEVER,THIS DOES NOT INCLUDE PROVISIONS ALREADY ESTABLISHED AS PART OF C. CLIENT,THE CONSTRUCTION MANAGER,AND WB ENGINEERS I CONSULTANTS WILL NOT BE Q. "NO SUBSTITUTES°: THE EXACT MAKE AND MODEL NUMBER IDENTIFIED IN THIS SPECIFICATION INSTALLATION,INCLUDING ALL DELETIONS FROM,ADDITIONS TO OR DEPARTURES FROM THE MAIN CONTRACTOR OR ELECTRICAL CONTRACTOR'S SCOPE OF WORK. A POSSESS THOSE LICENSESlPERMITS REQUIRED TO PERFORM RESPONSIBLE FOR ANY EXPENSE INCURRED BY THE BIDDER MADE IN CONNECTION WITH SHALL BE PROVIDED WITHOUT EXCEPTION. THE CONTRACT DOCUMENTS. THE MINIMUM REQUIREMENTS INCLUDE: TELECOMMUNICATIONS INSTALLATIONS IN THE JURISDICTION(S)OF THE PROJECT REVIEWING OR RESPONDING TO THIS DOCUMENT,OR INCURRED AT ANY TIME DURING THE 6. SUBCONTRACTOR SHALL PROVIDE A WEEKLY STATUS REPORT AT OR BY THE END OF PROPOSAL REVIEW AND AWARD PROCESS. ANY AND ALL SUCH EXPENSES SHALL BE THE R. "PBX": PRIVATE BRANCH EXCHANGE(TELEPHONE EQUIPMENT ROOM) LOCATION(S)- A INFORMATION OUTLET STATION NUMBERS AND CABLE ROUTING WHERE IT VARIES CLOSE OF BUSINESS ON A FRIDAY(OR THE PRECEDING DAY IF A FRIDAY FALLS ON A BIDDER'S SOLE RESPONSIBILITY. S. "POD":GROUP OF RACKS OR CABINETS WITHIN THE IDE,USUALLY CONSISTING OF 2 ROWS. FROM THE ORIGINAL PLAN PUBLIC HOLIDAY).THE REPORT SHALL BE SUBMITTED TO CONSULTANT IN EMAIL FORM- B PERSONNEL KNOWLEDGEABLE IN LOCAL,STATE,AND NATIONAL CODES AND D. IT IS THE INTENT OF THE DRAWINGS AND SPECIFICATIONS TO PROVIDE A COMPLETE T. "PROJECT SCHEDULE":MEANS SUBSETS OF THE WORK COMPLYING WITH SPECIFIC SCHEDULE ALL ISSUES AND CONCERNS PERTINENT TO MAINTAINING THE CONSTRUCTION REGULATIONS- ALL WORK SHALL COMPLY WITH THE LATEST REVISION OF CODES WORKABLE TELECOMMUNICATION AND IT NETWWORK INFRASTRUCTURE CABLING SYSTEM TARGETS WITHIN THE SUBCONTRACTORS SCHEDULE AS WELL AS THE COLLECTIVE B SLEEVE LOCATIONS SCHEDULE SHOULD BE ADDRESSED IN THIS FORMAT. ALL ISSUES AND CONCERNS OR REGULATIONS. WHEN CONFLICT EXISTS BETWEEN OWNER BEST PRACTICES, READY FOR CLIENT'S USE. ANY ITEMS NOT SPECIFICALLY SHOWN ON THE DRAWINGS OR COMPLETION DATES INDICATED WITHIN THE GENERAL CONTRACTORS SCHEDULE- C AS BUILT DRAWINGS SHALL BE SUBMITTED IN ELECTRONIC FORMAT ON A CD-ROM, SHALL BE NOTED IN THESE DOCUMENTS EOR COORDINATION WITH THE APPROPRIATE LOCAL OR NATIONAL CODES OR REGULATIONS,THE MOST STRINGENT CODES OR CALLED FOR IN THE SPECIFICATION,BUT NORMALLY REQUIRED FOR A COMPLETE SYSTEM, U. "PROVIDE": MEANS TO SUPPLY,PURCHASE,TRANSPORT,PLACE,ERECT,CONNECT,LABEL, IN AUTOCAD 2002,OR LATER.DWG AND PDF FILE FORMATS AS WELL AS IN PARTIES. ISSUES THAT ARE NOT DOCUMENTED SHflLL BE CONSIDERED SOLELY THE REGULATIONS SHALL BE FOLLOWED. ARE TO BE CONSIDERED A PART OF THE OVERALL CONTRACT. TEST AND TURN OVER TO THE OWNER A COMPLETE AND READY FOR REGULAR OPERATION, "HARD"PRINTOUT SETS. E. CONSIDERATION OTHER THAN COST ALONE WILL BE USED IN DETERMINING WHICH IS(ARE) ALL MATERIALS,LABOR,EQUIPMENT,TESTING APPARATUS,CONTROLS,TESTS,ACCESSORIES H. RECORD DOCUMENTS RESPONSIBILITY OF THE SUBCONTRACTOR,AND SHALL NOT BEA FACTOR IN THE C PROPOSERS SHALL DOCUMENT A MINIMUM OF FIVE YEARS'EXPERIENCE IN THE THE SUCCESSFUL BIDDER(S).THESE FACTORS WILL INCLUDE FINANCIAL STABILITY, AND ALL OTHER ITEMS CUSTOMARILY REQUIRED FORA TELECOMMUNICATIONS CABLING 1. RECORD DOCUMENTATION WILL CONSIST OF THE FOLLOWING: OVERALL CONSTRUCTION SCHEDULE. FABRICATION,ASSEMBLY AND INSTALLATION OF SYSTEMS OF SIMILAR COMPLEXITY AVAILABILITY,PREVIOUS PERFORMANCE,DESIGN SUPPORT,PROJECT MANAGEMENT AND SYSTEM,E.G.TO"FURNISH AND INSTALL". 7. THE SUBCONTRACTOR SHALL PROVIDE ANY AND ALL SLEEVE OR CONDUIT PATHWAYS AS SPECIFIED HEREIN. FIELD SUPERVISION- V. "PROVISION THE TERM"PROVISION"MEANS TO"FURNISH AND INSTALL,COMPLETE AND A FOUR(4)COMPLETE SETS OF AS-BUILT DRAWINGS "--. REQUIRED THAT ARE NOT ALREADY PROVIDED BY ELECTRICIAN(MEANING ON THE F. THE PRODUCTS SPECIFIED IN THIS DOCUMENT ARE TO BE USED EXCLUSIVELY. NO READY FOR THE INTENDED USE". D MUST POSSESS CURRENT INSURANCE COVERAGE'S AS REQUIRED BY THE B FOUR(4)COMPLETE SETS OF TEST DOCUMENTATION. """""" ELECTRICAL DRAWINGS,WHICH,BY REFERENCE,INCLUDE THE INFRASTRUCTURE AS SUBSTITUTIONS OF COMPONENTS SPECIFICALLY REFERENCED WELL BE ALLOWED,WITHOUT W."PUC ROOM":THE LOCATION WITHIN THE CUSTOMER PREMISES THAT IS THE ENTRANCE TO A CONSTRUCTION MANAGER AND CLIENT. C ONE(1)ORIGINAL AND THREE(3)COPIES OF ALL MANUFACTURER'S WARRANTIES PRIOR WRITTEN CONSENT FROM CLIENT OR WB ENGINEERS I CONSULTANTS AFTER BUILDING FOR BOTH PUBLIC AND PRIVATE NETWORK SERVICE CABLES(INCLUDING ANTENNAE) SHOWN ON THE IT DRAWINGS). IN OTHER WORDS,THE CONTRACTOR SHALL NOT SUBMITTAL REVIEW. INCLUDING THE POINT OF ENTRY AT THE BUILDING WALL AND CONTINUING TO THE ENTRANCE D ALL DOCUMENTATION,SUCH AS,AS-BUILT DOCUMENTATION,TEST C. SPECIFIC STAFFING,TRAINING AND CERTIFICATION REQUIREMENTS PENETRATE ANY SHEET ROCK WALLS AND PULL CABLE THROUGH HOLES IN THE G. THE BIDDER SHALL VISIT THE SITE OF TME PROPOSED WORK TO IDENTIFY ANY EXISTING ROOM OR SPACE. IT IS GENERALLY THE LOCATION OF THE(INTERFACE)DEMARCATION POINT DOCUMENTATION AND WARRANTIES SHALL BE KEPT ON FILE BY THE SHEETROCK. 1. SUBCONTRACTOR SHALL PROVIDE AND STAFF JOB WITH PERSONNEL TRAINED ANO BETYWEEN THE SERVICE PROVIDER'S CIRCUITS ANp THE CUSTOMER'S EQUIPMENT AND/OR SUBCONTRACTOR FOR THE ENTIRE TERM OF THE WARRANTY. CERTIFIED IN THE INSTALLATION OF THE SELECTED CABLING SYSTEM{I.E. GONDLTIONS THAT MAY AFFECT THE WORK,TO REVIEW THE DRAWINGS OF OTHER TRADES, 1.3D PERMITS,LICENSE INSPECTIONS AND FEES AND TO BECOME FAMILIAR WITH THE SITE IN GENERAL PRIOR TO SUBMITTING ITS PROPOSAL. PRIVATE NETWORK COMPONENTS. D. NOT IN CONTRACT WORK' MANUFACTURERS'CERTIFICATION). THE SUBCONTRACTOR SHALL BE HELD RESPONSIBLE FOR ANY ASSUMPTIONS MADE IN THAT X. "REVIEWED","SATISFACTORY","ACCEPTED°,"APPROVED",OR"DIRECTED"-AS REVIEWED, 1. CERTAIN ITEMS NECESSARY FOR COMPLETE AND OPERATIONAL SYSTEMS SHALL NOT A. ALL LOCAL PERMITS AND THE SERVICES OF REQUIRED INSPECTION AUTHORITIES WILL BE 2- CABLING SUBCONTRACTOR MUST BE AN APPROVED ORTRONICS CERTIFIED INSTALLER REGARD. S01ATTIISFR CTORY,ACCEPTED,APPROVED,OR DIRECTED BY THE ARCHITECT,ENGINEER AND OBTAINED AND PAID FOR BY THE SUBCONTRACTOR. BE PROVIDED BY SUBCONTRACTOR. HOWEVER,SUBCONTRACTOR IS RESPONSIBLE FOR AT A PLUS TIER(CIP,CIP-GOLD,CIP-PLATINUM,OR MULTI-SITE/NATIONAL AND OASIS H. THE BIDDER SHALL COMPLY WITH ALL APPLICABLE GOVERNMENTAL REGULATIONS AND WITH COORDINATING WITH THE GENERAL CONTRACTOR,ARCHITECT,AND ) B- THE SUBCONTRACTOR SHALL COOPERATE FULLY WITH LOCAL UTILITY COMPANIES WITH s ALL FEDERAL,STATE,CITY,AND OTHER APPLICABLE CODES AND ORDINANCES. Y. "SHALL"AND"WILL"ARE MANDATORY. SUB-CONTRACTORS(OR OTHER PARTIES}FOR ALL NIC MATERIALS THAT ARE RELATED CERTIFIED.THE TELECOMMUNICATIONS CONTRACTOR IS RESPONSIBLE FOR RESPECT TO THEIR SERVICES. THE SUBCONTRACTOR SHALL INCLUDE IN HIS PRICE AND WORKMANSHIP AND INSTALLATION PRACTICES IN ACCORDANCE WITH THE ORTRONICS I. THE WORK COVERED BY THIS SPECIFICATION INCLUDES THE INSTALLATION OF A COMPLETE Z. "SHOULD"IS ADVISORY. ITEMIZE ALL SUCH COSTS TO BE INCURRED RELATIVE TO THE INSTALLATION OF THE SYSTEM TO THE SPECIFIED SYSTEMS INSTALLATION. THESE NIC ITEMS MAY INCLUDE,BUT ARE CERTIFIED INSTALLER PROGRAM(CIP)AND OASIS.THE CERTIFIED CONTRACTOR SHALL TELECOMMUNICATION AND IT NETWORK INFRASTRUCTURE CABLING SYSTEM,INCLUDING ALL AA. "SUBCONTRACTOR"SYSTEMS SUBCONTRACTOR WHO HAS BEEN AWARDED THE DESCRIBED HEREIN. NOT LIMITED TO: LABOR NECESSARY TO PERFORM AND COMPLETE SUCH INSTALLATIONS,ALL MATERIALS AND CONTRACT TO PERFORM ANY OR ALL OF THE WORK AS SPECIFIED WITHIN THIS SPECIFICATION C. THE SUBCONTRACTOR SHALL BE RESPONSIBLE FOR COMPLIANCE WITH TME REQUIREMENTS HAVE 80%OF THEIR ON-SITE TECHNICIANS TRAINED ON COPPER&FIBER INSTALLATIONS EQUIPMENT INCORPORATED OR TO BE INCORPORATED IN SUCH INSTALLATIONS,AND ALL AND THE ASSOCIATED DRAW NGS. A ALL HIGH VOLTAGE POWER AND ELECTRICAL OUTLETS AND TESTING BY ORTRONICS;THEY ALSO SHALL HAVE AT LEAST 1 PROJECT MANAGER OF ALL AUTHORITIES HAVING JURISDICTION OVER THIS WORK,ANp SHALL BRING TO THE 1 SERVICES,SUPERVISION,CONSUMABLE ITEMS,FEES,LICENSES,FACILITIES,TOOLS,AND BB."SUPPLY"OR"FURNISH":MEANS TO PURCHASE,PROCURE,ACQUIRE,AND DELIVER IMMEDIATE ATTENTION OF THE CONSTRUCTION MANAGER ANY WORK THAT,AS DESIGNED, B ALL SLEEVES AND CONDUITS AS RELATED TO THE RISER DRAWINGS SUCCESSFULLY COMPLETE AN ORTRONICS 2-DAY MANAGEMENT CERTIFICATION CLASS. EQUIPMENT NECESSARY OR USED TO PERFORM AND COMPLETE SUCH INSTALLATIONS WITHIN COMPLETE WITH RELATED ACCESSORIES- WILL NOT COMPLY WITH REQUIREMENTS. C ALL BACK BOXES IN CLEAN ROOM WALLS,WHICH ARE PROVIDED WITH CLEAN ROOM D. PERFORMANCE AND PAYMENT BOND THE TIMEFRAMES REQUIRED IN THE PROJECT SCHEDULE. CC. "TELECOMMUNICATIONS":COMMUNICATIONS(EXCHANGE OF INFORMATION)OVER 1.31 SUBSTITUTIONS PRE-INSTALLED. 1- REFER TO CONSTRUCTION MANAGER'S REQUIREMENTS 1.19 COMPLIANCE WITH CODES,REGULATIONS,AND STANDARDS DISTANCE.THE TRANSMISSION OF INTELLIGENCE COMPRISES VOICE,DATA,VIDEO,IMAGING, D ALL PLYWOOD BACKBOARDS AND ANY OTHER SIGNALING FOR THE PURPOSE OF THE TRANSFER OF INFORMATION. THIS IS A. NO SUBSTITUTIONS WILL BE ACCEPTED WITHOUT WRITTEN PERMISSION FROM E. INSURANCE A. ALL INSTALLATIONS AND EQUIPMENT SHALL BE IN COMPLIANCE WITH,EQUAL Td OR EXCEED OWNER/CONSULTANT- ANY PROPOSED SUBSTITUTIONS MUST BE CLEARLY DELINEATED IN E ALL HORIZONTAL CONDUITS,JUNCTION BOXES,BACK BOXES AND CONDUIT THE MINIMUM REQUIREMENTS OF OSHA,NEC,NEMA,€EEE,ANSI,UL,E€AlTIA IRRESPECTIVE OF THE SIGNALING FORMAT WHETHER ANALOG OR DIGITAL,BASEBAND OR 1. REFER TO CONSTRUCTION MANAGER'S REQUIREMENTS BROADBAND,OR OF MEDIA TYPE WHETHER COPPER(TWISTED-PAIR OR COAXIAL),FIBER THE Blp PROCESS AS SUCH. THE OWNERIENGINEER RESERVES THE RIGHT TO REJECT ANY STUB-UPS. RECOMMENDATIONS AND THE RULES,REGULATIONS AND REQUIREMENTS OF THE FEDERAL F ALL STRUCTURAL WORK,WALL OPENINGS,PLATFORMS,RAILINGS,STAIRS,FIRE COMMUNICATIONS COMMISSION- (SINGLE-MODE OR MULTI-MODE),OR OPEN SPACE TRANSMISSION{RADIO RF,MICROWAVE,OR PROPOSED SUBSTITUTION AND THE SUBCONTRACTOR SHALL FURNISH AND INSTALL OR REVI SI ONS: 1.09 INSTRUCTION TO BIDDERS INFRARED), TELECOMMUNICATIONS IS ANY TRANSMISSION,EMISSION,AND RECEPTION OF REPLACE THE SUBSTITUTED MATERIALS WITH THE SPECIFIED MATERIALS AT NO ADDITIONAL PREVEN ION AND SAFETY DEVICES,ROUGH AND FINISHED TRIM,PAINTING AND B. THE INSTALLATION SHALL COMPLY FULLY WITH ALL APPLICABLE COUNTY AND STATE LAWS, COST TO OWNER/ENGINEER WHERE PROPER APPROVALS HAVE NOT BEEN ISSUED. SIGNS,SIGNALS,WRITINGS,IMAGES,AND SOUNDS THAT IS INFORMATION Of ANY NATURE BY ISSUED FOR BID-PERMIT 06.06.17 PATCHING,CARPETS,FLOOR COVERINGS,COMPUTER FLOORS,AND HEATING, A. RECEIPT ORDINANCES,REGULATIONS,AND CODES. 1.32 SCHEDULING VENTILATING,AND AIR CONDITIONING SYSTEMS- 1. REFER TO CONSTRUCTION MANAGER'S REQUIREMENTS. CABLE,RADIO,OPTICAL OR OTHER ELECTROMAGNETIC MEANS. C. LOCAL ELECTRICAL AND BUILDING CODES MAY BE MORE STRINGENT THAN NATIONAL CODES, DD. "WAP":WIRELESS ACCESS POINT E. RELATED WORK SPECIFIED ELSEWHERE: RECOMMENDATIONS OR PRACTICE. FOLLOW THE MOST RESTRICTIVE CODE OR A. REFER TO CONSTRUCTION MANAGER'S REQUIREMENTS B. DUE DATE EE."WIRING"OR"CABLING":INCLUDES PROVIDING,UNLESS OTHERWISE NOTED,ALL FITTINGS, la 1. ELECTRICAL POWER AND RACEWAY ARE TO BE PROVIDED AND INSTALLED BY OTHERS, RECOMMENDATIONS. 1.33 PERIODIC FIELD OBSERVATION REPORT i 3 UNLESS OTHERWISE INDICATED.ELECTRICAL OUTLETS ABOVE RACKS AND CABINETS IN 1- REFER TO CONSTRUCTION MANAGER'S REQUIREMENTS- D. SHOULD ANY CHANGE IN PLANS OR SPECIFICATIONS BE REQUIRED TO COMPLY WITH HANGERS,SUPPORTS,SLEEVES,ETC. n FF."WORK AREA°(WORK STATION): A BUILDING SPACE WHERE THE OCCUPANTS INTERACT WITH A. THE CLIENT/CONSULTANT SHALL ISSUE PERIODIC FIELD OBSERVATION REPORTS TO THE THE MDF AND IDE ARE TO BE PROVIDED AND INSTALLED BY OTHERS. C. RETURN OF PROPOSAL GOVERNMENTAL REGULATIONS OR INDUSTRY STANDARDS,THE SUBCONTRACTOR SHALL TELECOMMUNICATIONS TERMINAL EQUIPMENT. THERE MAY BE MORE THAN ONE CONSTRUCTION MANAGER. THE SUBCONTRACTOR SHALL IMMEDIATELY REMEDY ANY ♦ 1. THE BIDDER WHO ELECTS NOT TO SUBMIT A BID SHALL RETURN ALL MATERIALS INTACT. NOTIFY THE CONSTRUCTION MANAGER A7 THE TIME OF BID SUBMISSION. I O 2. NETWORK EQUIPMENT,INCLUDING WIRELESS ACCESS POINTS,WHICH SHALL 8E TELECOMMUNICATIONS OUTLET(TO)OR WORK AREA OUTLET(WAO)IN A WORK AREA OR DEFICIENT WORK- IN NO EVENT SHALL DEFICIENCIES IN THE SUBCONTRACTORS WORK 5 1.20 REFERENCE CODES AND S7ANDAR05 THERE MAY BE ONE MULTI-USER TELECOMMUNICATIONS OUTLET ASSEMBLY MUTOA FOR CONSTITUTE GROUNDS OR BASIS FOR AN EXTENS€ON OF THE CONTRACT TIME OR SCHEDULE r.. PROVIDED BY CLIENT. D. RESPONSE INSTRUCTIONS ( ) i 1. RESPONSES WILL FOLLOW INSTRUCTIONS PROVIDED BY OWNERICONSULTANT. A. THE FOLLOWING CODES AND STANDARDS APPLY: SEVERAL WORK AREAS. SUBSET DURATIONS. F. DELIVERY,STORAGE AND HANDLING 1. AMERICAN NATIONAL STANDARDS INSTITUTE(ANSI) GG. "WORKMANLIKE":BEFITTING A SKILLED ARTISAN OR CRAFTSPERSON SPECIFIC TO THE 1.34 CLEANUP 1. COSTS OF ALL SHIPPING TO THE SITE,AND OF ALL UNUSUAL STORAGE REQUIREMENTS, 2. ALL HARD COPY AND ELECTRONIC PRICING FORMS REQUIRED BY THIS SPECIFICATION FIELD OF TELECOMMUNICATIONS UTILIZING AND ADHERING TO THE HIGHEST STANDARDS AND A. REFER TO CONSTRUCTION MANAGER'S REQUIREMENTS FOR CLEANUP REQUIREMENTS AND p SHALL BE BORNE BY THE SUBCONTRACTOR. IT SHALL BE THE RESPONSIBILITY OF MUST BE FULLY COMPLETED,EVEN IF REDUNDANT TO OWNERICONSULTANT FORMS. 2. AMERICANS WITH DISABILITIES ACT(ADA) BEST PRACTICES AS SET FORTH AND/OR DEFINED BY BICSIO,ANSIIEIA/TIA,IEEE AND THIS I SUBCONTRACTOR TO MAKE APPROPRIATE ARRANGEMENTS,AND TO COORDINATE WITH SPECIFICATION.IT INDICATES A JOB SKILLFULLY DONE,BECOMING A WORKMAN,ESPECIALLY ANY LIED DEBRIS DISPOSAL REQUIREMENTS. AUTHORIZED PERSONNEL AT THE SITE,FOR THE PROPER ACCEPTANCE,HANDLING, 3. DESIGN DRAWINGS FOR THE PROJECT ACCOMPANY THIS BID SPECIFICATION. THE BID 3. BUILDING OFFICIALS AND CODE ADMINISTRATORS,INTERNATIONAL(BOCA)THE BOCA B. CLEANUP AND REMOVAL OF DEBRIS IS THE RESPONSIBILITY OF THE SUBCONTRACTOR.IF THE WELL PERFORMED. SPECIFICATION DOCUMENT IS AN ALL-ENCOMPASSING DOCUMENT WITH TECHNICAL NATIONAL BUILDING CODE SUBCONTRACTOR DOES NOT CLEANUP AND REMOVE DEBRIS PRIOR TO CONCLUDING ITS PROTECTION,AND STORAGE OF EQUIPMENT SO DELIVERED. HH. ZONE'SEPARATE GROUP OF LOUDSPEAKERS AND ASSOCIATED SUPPLY WIRING THAT WORK THE SAME DAY,THE CONSTRUCTION MANAGER WILL PERFORM THIS FUNCTION AND THE 3 SPECIFICATIONS AND PRICING REQUIREMENTS ADDRESSING TERMS,CONDITIONS, 4. ELECTRONIC INDUSTRIES ASSOCIATION(EIA) MAY BE ARRANGED FOR SELECTIVE SWITCHING BETWEEN DIFFERENT CHANNELS. SUBCONTRACTOR WILL BE BACK CHARGED FOR THIS WORK. ', 2. MOVEMENT OF MATERIAL EITHER AT THE TIME OF DELIVERY OR SUBSEQUENTLY SHALL INSTALLATION,AND TESTING REQUIREMENTS. 5. INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS{IEEE 1.24 CHANGES,INCREASES,OR REDUCTIONS IN WORK C. THE SUBCONTRACTOR WILL BE HELD ACCOUNTABLE FOR ANY DAMAGE DONE TO THE C.D ' BE THE SOLE RESPONSIBILITY OF SUBCONTRACTOR AS SHALL ALL COSTS ASSOCIATED ) 4. THIS DOCUMENT AND THE ASSOCIATED DRAWINGS ARE BASED ON CURRENTLY KNOWN A. REFER TO CONSTRUCTION MANAGER'S REQUIREMENTS PROPERTY OR WORK OF OTHER TRADES(LE CEILING TILE,PAINTED WALLS,ETC,)AND WILL BE WITH THIS MOVEMENT. CONDITIONS AND SITUATIONS. ANOMALIES MAY EXIST OF WHICH CLIENT AND WVB fi. NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION(NEMA}STANDARDS BACK CHARGED FOR ANY REQUIRED REPAIRS INCLUDING CHARGES TO EXPEDITE DELIVERY 1.25 STAFFING g G. PROJECT CONDITIONS: ENGINEERS I CONSULTANTS ARE NOT AWARE. 7. NATIONAL FIRE PROTECTION ASSOCIATION(NFPA 70) OF MATERIALS AND PREMIUM TIME ASSOCIATED WITH SUCH REPLACEMENT AND/OR REPAIR. 1. CONTRACTOR SHALL STRIVE FOR LABOR HARMONY. A. THE SUBCONTRACTOR SHALL PROVIDE A SUPERVISORY WORK FORCE SUFFICIENT TO 1.35 SEQUENCING AND SCHEDULING C 5. CONFIDENTIALITY: THE INFORMATION AND DATA CONTAINED IN THE BID PACKAGE IS B. NATIONAL FIRE PROTECTION ASSOCIATION LIFE SAFETY CODE MAINTAIN EFFICIENT PERFORMANCE OF THE SUBCONTRACTOR'S RESPONSIBILITIES. A. WORK NECESSARY TO BE PERFORMED AFTER REGULAR WORKING HOURS,ON SUNDAYS,OR 2. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF HIS WORK FROM ACTS OF CONFIDENTIAL CLIENT INFORMATION. ANON-DISCLOSURE AGREEMENTlS REQUIRED BY B. FULLTIME FOREMAN AND PROJECT MANAGER --- -- - - - - _ - - - 9. NATIONAL ELECTRICAL SAFETY CODE{NESC)IEEE C2 LEGAL HOLIDAYS,SHALL BE PERFORMED WITHOUT ADDITIONAL EXPENSE TO CLIENT. CLIENT VANDALISM AND ENVIRONMENTAL CONDITIONS. THE OWNER PRIOR TO CONTRACTING. 1. THE SVBCONTRACTOR SHALL DESIGNATE IN WRITING TO THE CONSTRUCTION MANAGER DRAWING BY: 10. NFPA,NATIONAL FIRE CODES(NFC) A DEDICATED,FULL TIME FOREMAN AS CONTACT FOR RESOLUTION OF PROBLEMS,JOB WILL NOT HONOR SUBSEQUENT REQUESTS FOR PREMIUM LABOR RATES OR OVERTIME. THE 3. CONTRACTOR SHALL CLEAN UP AND REPAIR ALL AREAS AFFECTED BY HIS 6. THE BIDDER SHALL NOT DISCLOSE TO ANYONE OTHER THAN CLIENT EMPLOYEES AND SUBCONTRACTOR WILL ASSUME THF RISK OF PROPER SCHEDULING TO MEET ANY IMPOSED O € INSTALLATION- OFFICERS,AND SUBCONTRACTOR'S EMPLOYEES AND OFFICERS DIRECTLY CONNECTED COORDINATION,ADDITIONS,CHANGES,ETC.,WHO SHALL BE PRESENT IN THE FIELD AT DEADLINES. 11- RHODE ISLAND BUILDING AND ELECTRICAL CODES WITH THIS BID PACKAGE,ANY INFORMA710N CONCERNING THIS BID. ALL TIMES DURING THE PERFORMANCE OF THE WORK. B. THE SUBCONTRACTOR IS RESPONSIBLE TO ORDER AND STAGE ALL MATERIALS DELIVERY INA DATE; June 06, 2017 4- CONTRACTOR MUST ATTEND ALL JOB MEETINGS,UNLESS TOLD OTHERWISE BY THE 12. TELECOMMUNICATIONS INDUSTRIES ASSOCIATION CTIA) TIMELY MANNER,INCLUDING ANY CHARGES 70 EXPEDITE DELIVERY OF MATERIALS AND �+ OWNER'S REPRESENTATIVE. 7- ALL INFORMATION HAS BEEN PROVIDED FOR PROPOSAL PURPOSES ONLY,AND IS NOT 2. THE SUBCONTRACTOR SHALL DESIGNATE IN WWRITING TO THE CONSTRUCTION MANAGER 13. UNIFORM BUILDING CODE(UBC) A DEDICATED,FULL TIME PROJECT MANAGER AS CONTACT FOR ESCALATION OF PREMIUM TIME ASSOCIATED WITH MAINTAINING THE PROJECT SCHEDULE FOR THE SCOPE OF '� i TO BE USED OR DISCLOSED BY YOU,OTHER THAN IN CONNECTION WITH YOUR BID. WORK DEFINED HEREIN. JOB NUMBER: 02GPD-170493 1 , 5. CONTRACTOR SHALL DOCUMENT ALL ACTIVITIES PERTAINING TO THE SCHEDULE OF THE RESOLUTION OF PROBLEMS,JOB COORDINATION,ADDITIONS,CHANGES,ETC.,WHO SECURITY SYSTEM IMPLEMENTATION.THIS DOCUMENTATION SHALL BE USED AS A 8. NO NEWS RELEASE,PUBLIC ANNOUNCEMENT,DENIAL OR CONFIRMATION OF ANY PART 14. UNIFORM FEDERAL ACCESSIBILITY STANDARDS(UPAS) 1.36 COORDINATION SHALL BE PRESENT AT CONSTRUCTION MEETINGS AS REQUIRED BY THE -- ^����^-�°°°- -- - -- -"a-- ' GENERAL STATUS REPORT FOR GENERAL CONSTRUCTION PURPOSES. ALL ISSUES AND OF THE SUBJECT MATTER OF THIS BID PACKAGE OR ANY PHASE OF ANY PROGRAM HERE 15- UNDERWRITERS LABORATORIES(UL)APPLICABLE STANDARDS FOR SAFETY CONSTRUCTION MANAGER AND SHALL PERIODICALLY BE IN THE FIELD TO ADDRESS ANY A. CAREFULLY CHECK SPACE REQUIREMENTS AND THE PHYSICAL CONFINES OF THE AREAS OF TITLE• CONCERNS SHALL BE NOTED IN THESE DOCUMENTS FOR COORDINATION WITH THE UNDER SHALL BE MADE WITHOUT THE PRIOR WRITTEN CONSENT OF CLIENT- g, ALL MATERIALS AND INSTALLATION PRACTICES SHALL COMPLY WITH THE APPLICABLE QUALITY CONTROL OR SCHEDULE ISSUES AND ASSURE WORK IS BEING PERFORMED IN WORK TO ENSURE THAT ALL MATERIAL CAN BE INSTALLED IN THE SPACES ALLOTTED • .. APPROPRIATE PARTIES. ISSUES THAT ARE NOT DOCUMENTED SHALL.BE CONSIDERED COMPLIANCE WITH THE CONTRACT DOCUMENTS. THE PROJECT MANAGER SHALL THERETO,INCLUDING BELOW RAISED FLOOR CABLE TRAY,RISER SPACE AND SLEEVES, 9. COMPLIANCE WITH REQUIREMENTS: THE BIDDER SHALL CONFIRM THAT IN ALL SECTIONS OF THE FOLLOWING TELECOMMUNICATIONS INDUSTRY STANDARDS RACEWAYS,CONDUITS,AND CABLE REELS ETC. rij 0 ^ SOLELY THE RESPONSIBILITY OF THE SUBCONTRACTOR,AND SHALL NOT BE A FACTOR NOTIFY THE CONSTRUCTION MANAGER AND WB ENGINEERS I CONSULTANTS A MINIMUM TE LE C 0 M M U N I C A TI 0 N S O RESPECTS THE BIDDER'S QUOTATION CONFORMS TO ALL SPECIFICATIONS,TERMS AND 1. ANSIITIAIEIA-568-6.1,COMMERCIAL BUILDING TELECOMMUNICATIONS CABLING B. TRANSMIT TO CONSTRUCTION MANAGER ALL INFORMATION NECESSARY FOR ANY WORK iN THE OVERALL CONSTRUCTION SCHEDULE. CONDITIONS INCORPORATED AND MADE A PART OF THIS BID PACKAGE- STANDARD,PART 1:GENERAL REQUIREMENTS. OF ONE DAY PRIOR TO SITE VISIT SO THEY CAN ARRANGE A PROJECT WALK THROUGH nj REQUIRED 8Y OTHER TRADES AND/OR EQUIPMENT SUBCONTRACTORS IN A TIMELY MANNER SPECIFICATION S WITH THE PM IF DESIRED. 1.06 SCOPE OF WORK TO ENSURE THAT THE PROJECT SCHEDULE IS MAINTAINED AND THAT ALL 5 M 10- THE BIDDER WILL ENSURE THAT RESPONSES ARE MADE IN THE SAME ORDER AND USING 2. ANSIITIAIEIA-568 B.2,COMMERCIAL BUILDING TELECOMMUNICATIONS CABL/NG TRADES/SUBCONTRACTORS HAVE THE INFORMATION NECESSARY TO PROPERLY INSTALL ALL A. FURNISHING AND INSTALLATION OF ALL PAIRED COPPER,OPTICAL FIBER,AND COAXIAL CABLE THE SAME NUMBERING CONVENTIONS AS USED IN THIS SPECIFICATION IN ORDER TO STANDARD,PART 2:BALANCED TWISTED-PAIR CABLING COMPONENTS. 3. THE SUBCONTRACTOR'S FOREMAN SHALL HAVE FULLAUTHORITY TO REPRESENT THE N SUBCONTRACTOR IN MAKING DECISIONS AND EXECUTING THE WORK IN AN ACCEPTABLE NECESSARY CONNECTIONS AND EQUIPMENT. FOR THE TRANSPORT OF VOICE,DATA,AND VIDEO INFORMATION. FACILITATE THE EVALUATION PROCESS, SHEET NUMBER: I tO B. PROVISION OF PATCH PANELS AND DISTRIBUTION EQUIPMENT,TERMINATION BLOCKS AND 3. ANSIITIA/EIA-568-B.3,COMMERCIAL BUILDING TELECOMMUNICATIONS CABLING MANNER. C PROVIDE TIMELY NOTICE TO IDENTIFY ALL ITEMS OF WORK THAT REQUIRE ACCESS SO THAT CONNECTORS,CABLE SUPPORTS,HARDWARE AND FITTINGS,ETC.IN SUFFICIENT QUANTITY 11- THE BIDDER SHOULD ENSURE THAT ALL REQUIRED INFORMATION IS INCLUDED IN HIS STANDARD,PART 3:OPTICAL FIBER CABLING COMPONENTS STANDARD. THE CONSTRUCTION MANAGER MAY ARRANGE FOR SUCH ACCESS WITHIN THE TIME c c G RESPONSE AND STATE ACCEPTANCE OF CONFORMANCE OR OTHERWISE,TO EACH AND 4- THE SUBCONTRACTOR AS PART OF THIS BID RESPONSE SHALL SUPPLY A RESUME OF CONSTRAINTS OF THE PROJECT SCHEDULE. a TO TERMINATE ALL COMMUNICATIONS CABLING INSTALLED UNDER THIS CONTRACT: 4. ANSI/TIAIEIA-569 A,COMMERCIAL BUILDING STANDARDS FOR TELECOMMUNICATIONS THE FULLTIME FOREMAN AND THE RESUME OF THE PROJECT MANAGER D. ANY SUBCONTRACTOR HAND DELIVERED ITEMS MUST BE SIGNED OFF BY THE OWNER WHO 1_ PROVIDE,INSTALL AND TERMINATE ALL VOICE,DATA,AND V€DEO HORIZONTAL EVERY POINT IN THIS SPECIFICATION. PATHWAYS AND SPACES(FIPS 175-FEDERAL INFORMATION PROCESSING STANDARD) WILL VERIFY AND AGREE THE QUANTITY DELIVERED. T C, CRAFT PE T PA E A REFLECTED ON DRAWINGS RSONNEL SHALL BE QUALIFIED TO PERF ED LE 4 s 6 TELECOMMUNICATIONS CABLING IN THE CLIEN 5 C S � 12- NEUTRAL COMMENTS SUCH AS"NOTED"WILL NOT BE ACCEPTED AS A COMPLIANT ORM THE WORK ANO BE KNOWL Gl:A6 1.37 DELIVERY ANp HANDLING .--, a SPECIFICATIONS AND SKETCHES 5. ANSIITIAIEIA-598-A,OPTICAL FIBER CABLE COLOR CODING OF THE FOLLOWING ACTIVITIES: STATEMENT. ANY FAILURE ANp!OR INCOMPLETENESS IN THIS RESPECT MAY RESULT IN H 2. PROVIDE AND INSTALL ALL WORK AREA OUTLET HARDWARE,TERMINATION MODULES, REJECTION OF YOUR RESPONSE. 6. ANSI/TIAIEIA-606,THE ADMINISTRATION STANDARD FOR THE TELECOMMUNICATIONS 1. COB SCODING OF STANDARD AMER€CAN TELEPHONE!DATA TELECOMMUNICATIONS A. MANUFACTOU ERSEU OPENED CONTAI E RIALS(EX IDENB TIED WITH MANUIFACTURERS'NAME, COMMENTS" ICONS,ETC- INFRASTRUCTURE OF COMMERCIAL BUILDING II II E 13. SUBSTITUTIONS'NO SUBSTITUTIONS WILL BE ACCEPTED. TRADE NAME,TYPE,CLASS,GRADE,SIZE,AND COLOR. 0 2. INSTALLATION AND TESTING OF CATEGORY 6 UTP CABLING AND DEVICES B. SHIP ALL PRODUCTS AND MATERIALS IN A MANNER THAT WILL PROTECT THEM FROM DAMAGE, G -. _ ..._ >_�.. ,... _.,..._.. -...._ �_ .. ....... .... ........... .. ... ........ WEATHER,AND ENTRY OF DEBRIS, IF ITEMS ARE DAMAGED,DO NOT INSTALL,BUT TAKE EIAJTIA T-568B WRING PIN-OUT. THE OUTLETS SHALL BE DESIGNED TO SNAP INTO THE K. FASTEN TO BEAM OR FLANGE WITH ONE J-HOOK CABLE SUPPORT,FACTORY OR JOBSITE J. WHEN SEALANT IS INJECTED INTO A PENETRATION,THE FOAM SHALL EXPAND TO SURROUND RACKS AND CABINETS UNTIL THE OWNER AND ENGINEER APPROVES THE IMMEDIATE STEPS TO OBTAIN REPLACEMENT. FACEPLATE,FRAME AND SURFACE-MOUNT BOX. FURNISH AND INSTALL: ASSEMBLED;RATED FOR INDOOR USE IN NON-CORROSIVE ENVIRONMENTS;CULUS LISTED; ALL THE ITEMS WITHIN THE PENETRATION AS WELL AS THE PASS-MINUTES AND BE FIRE INSTALLATION. ERICO CABLECATTM J-HOOK SERIES CAT12,CAT21,CAT32,CAT64 WITH CADDY BEAM CLAMPS RESISTANT AT THAT TIME. C. OVERTIME DELIVERY MAY BE REQUIRED FOR THE ANY/ALL DELIVERIES,DEPENDING ON A DATA-SINGLE 8-PIN MODULAR JACK WITH T-5688 WIRING(BLACK);ORTRONICS CURRENT SCHEDULING AND SITE LOGISTICS. SUBCONTRACTOR WILL ABSORB THE COSTS ( ) AND CADDY FLANGE CLIPS, K. NO HEAT SHALL BE REQUIRED TO FURTHER EXPAND THE FOAM TO BLOCK THE PASSAGE OF 8 UPON APPROVAL BY THE OWNER AND ENGINEER TO PROCEED,ASSURE THAT ALL PART NO.OR-TJ600-00 TECHNICIANS ARE AWARE OF THE BENCHMARKS ESTABLISHED BY THE INITIAL ASSOCIATED WITH ANY REQUIREMENTS FOR OVERTIME DELIVERIES IMPOSED BY THE L. FASTEN TO WALL,CONCRETE,OR JOIST WITH ONE J-HOOK CABLE SUPPORT,FACTORY OR FIRE AND SMOKE OR WATER_ CONSTRUCTION MANAGER. B VOICE-SINGLE 8-PIN MODULAR JACK WITH T-5686 WIRING(GRAY);ORTRONICS JOBSITE ASSEMBLED;RATED FOR INDOOR USE IN NON-CORROSIVE ENVIRONMENTS,CULUS L. THE FOAM SEALANT SHALL HAVE BEEN SUBJECTED TO FIRE EXPOSURE IN ACCORDANCE WITH INSTALLATION AND THAT A STRICT LEVEL OF CONFORMITY IS ADHERED 1.38 LABELING REQUIREMENTS PART NO.OR-TJ600-78 LISTED;ERICO CABLECATTM J-HOOK SERIES CAT12,CAT21,CAT32,CAT64,WITH CADDY ANGLE STANDARD TIME-TEMPERATURE CURVE IN THE STANDARD,UL,ASTM E 119,AND NJPA 251. THROUGHOUT THE PROJECT. BRACKET M. THE FOAM FIRE-STOP SHALL HAVE ALSO BEEN SUBJECTED TO THE HOSE STREAM TEST IN A. THE SUBCONTRACTOR SHALL FURNISH AND INSTALL LABELS FOR OUTLETS,CABLES,AND 2. UNUSED INFORMATION OUTLET PORTS SHALL BE FULLY POPULATED WITH BLANK M. FASTEN TO THREADED ROD WITH ONE J-HOOK CABLE SUPPORT,FACTORY OR JOBSITE ACCORDANCE WITH UL 108. 2. ALL CABLES SHALL BE DRESSED IN A NEAT MANNER,OBSERVING CABLE BEND RADIUS TERMINATION HARDWARE AND EQUIPMENT,AS SPECIFIED HEREIN,AND AS SHOWN ON INSERTS. FURNISH AND INSTALL: ASSEMBLED,RATED FOR INDOOR USE IN NON-CORROSIVE ENVIRONMENTS,CULUS LISTED. LIMIT AT EACH EQUIPMENT RACK AND ON LADDER RACKS AND CABLE TRAYS. - DRAWINGS. THE MULTI-TIERED SUPPORT BRACKET SHALL HAVE A STATIC LOAD LIMIT OF 300 LBS. 3.06 CABLE HANGERS AND SUPPORTS 1.39 GENERAL TESTING REQUIREMENTS . • N. U-HOOKS AND DOUBLE J-HOOK SHALL ATTACH DIRECTLY TO THREADED ROD USING STANDARD A. WHERE CABLE TRAY IS NOT PROVIDED BY THE ELECTRICAL CONTRACTOR,THE 3. WALL-MOUNT MODULAR FACEPLATES SHALL BE CLOUD WHITE IN COLOR. FURNISH AND NUTS;ERICO CABLECATTM J-HOOK,CAT12,CAT21,CAT32,CAT64 WITH CADDY CATHBA SERIES; SUBCONTRACTOR IS RESPONSIBLE FOR THE SUPPORTING OF CABLES INSTALLED UNDER THE 4. CABLES MUST BE SECURELY BUNDLED,BUT MAY NOT DISPLAY INSULATION/SHEATH eat A. BEFORE AN APPLICATION FOR FINAL ACCEPTANCE OF THE WORK WILL BE CONSIDERED,ALL INSTALL: CAT-CMTM DOUBLE J-HOOK CAT100CM,CAT-CMTM DIRECT MOUNT U-HOOK CAT200CMLN, RAISED FLOOR SYSTEM. CABLE SUPPORTS ARE TO BE SEPARATE FROM FLOOR SUPPORTS, DAMAGE OR PAIR DISTORTION FROM OVER-TIGHTENING OF CABLE TIES- - TESTS REQUIRED BY THIS DOCUMENT SHALL BE SATISFACTORILY COMPLETED,WITH FULL TEST RESULTS SUBMITTED AND REVIEWED,AND MANUFACTURER'S CERTIFICATION ISSUED. A FACEPLATE FOR WALL-MOUNT OUTLETS;ORTRONICS PART NO.OR-40300545-88 CAT300CMLN;OR AFAB SERIES. PIPING,CONDUITS,AND DUCTWORK. B. ALL COMPONENTS OF INSTALLED CABLE PLANT MUST CONFORM TO EIA/TLA AND ALL OTHER B. UNDER NO CIRCUMSTANCES SHALL CABLE BE SUSPENDED FROM ANY PORTION OF UNDER 5. CABLING AT RACKS MUST BE NEATLY DRESSED AND VELCRO TIE WRAPPED. PLASTIC RELATED INDUSTRIAL PRACTICES AND STANDARDS,BUILDING TRADES,AND ELECTRICAL AND 4- FURNITURE MOUNTED MODULAR FACEPLATES SHALL BE BLACK IN COLOR. FURNISH 2.09 FIRE STOP SLEEVES FLOOR SPACE NOT SPECIFICALLY INSTALLED FOR CABLE SYSTEM ROUTING. TIE-WRAPS ARE PROHIBITED FOR USE IN THIS INSTALLATION . TELECOMMUNICATIONS INDUSTRY STANDARDS AND PRACTICES CURRENTLY IN PLACE. AND INSTALL: C. CONTRACTOR SHALL EXCLUSIVELY UTILIZE THREADED ROD,BEAM CLAMPS,WIRE TRAY, 6. AT COPPER PATCH PANELS,COPPER CABLING SHALL BE INSTALLED ACROSS THE TOP C. UPON COMPLETION OF TESTING AND PROBLEM RESOLUTION,ALL CONNECTIONS MUST BE A. ALL PENETRATIONS THROUGH FIRE WALLS WILL HAVE FIRE RE-PENETRABLE,CABLE LADDER RACK,J-HOOKS,AND OTHER RELATED HARDWARE FOR CABLE SUPPORT. OF STRAIN-RELIEF BAR,NEATLY BUNDLED,AND ROUTED STRAIGHT INTO THE AREA 100%ERROR FREE,WHERE'ERROR FREE"IS DEFINED TO MEAN THE ITEM MEETS ALL THE A 3-PORT FURNITURE FACEPLATE;ORTRONICS PART NO.OR-42100054-00 MANAGEMENT PRODUCTS FOR USE WITH NEW CABLE BUNDLES PENETRATING GYPSUM OR APPROPRIATE CABLE SUPPORTS SHALL BE USED AT ALL TIMES TO PREVENT UNNECESSARY BETWEEN THE APPLICABLE IDC TERMINATION STRIPS(BELOW THE UPPER STRIP AND STORE �` MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS AS PUBLISHED IN THEIR LATEST B BLANK INSERT;ORTRONICS PART NO.OR-42100002MASONRY WALLS,THE FOLLOWING PRODUCTS ARE ACCEPTABLE: TENSION OR SLACK IN THE CABLE BUNDLES EXITING THE UNDER FLOOR CABLE TRAY. . (FOG WHITE) ABOVE THE LOWER STRIP OF THE TWO SERVING A GIVEN MODULE OF JACKS). NO MORE CORAM MANUFACTURING MANUALS FOR PROPER INSTALLATION AND TESTING. 1. 1. HILTI SPEED SLEEVE(CP 653)FOR OPENINGS EQUAL TO OR LESS THAN D. ALL PATHWAY COMPONENTS SHALL BE INSTALLED ACCORDING TO MANUFACTURER INC. 5. FURNITURE FACEPLATE BEZELS SHALL BE BLACK IN COLOR. FURNISH AND INSTALL: SPECIFICATION INSULATION THAN IS NEEDED TO TERMINATE THE CABLE IN THIS POSITION SHALL BE 1.40 WARRANTY 4°DIAMETER. STRIPPED FROM THE CABLE. INDIVIDUAL PAIRS SHALL MAINTAIN TWIST INTEGRITY TO 7358 S W DURHAM RD. E. THE SUBCONTRACTOR SHALL FOLLOW THE ROUTES INDICATED ON THE DISTRIBUTION PLANS, A FURNITURE FACEPLATE BEZEL;ORTRONICS PART NO.OR-40300633-00 OR EQUAL 4 WITHIN.5"(ONE HALF-INCH)OF THE TERMINATION POINT. A. PROVIDE WARRANTY AND SUPPORT FOR THE ENTIRE IDF CABLE PLANT. PORT PLATE TO FIT OPENING. 2. HILT!FIRESTOP BLOCK(CFS-BL)FOR OPENINGS LARGER THAN 4'DIAMETER. CABLES INSTALLED OUTSIDE OF THESE PATHWAYS WILL BE REMOVED AND REROUTED AT 1. THE TELECOMMUNICATIONS CONTRACTOR MUST BE AN APPROVED ORTRONICS TELECOMMUNICATIONS CABLING SUBCONTRACTOR'S EXPENSE, 7. CABLE DRESSING DEEMED NOT TD CONFORM TO THE CABLE DRESSING AND PORTLAND, OR 97224 B. RE-PENETRABLE,CABLE MANAGEMENT PRODUCTS FOR USE WITH PRE-EXISTING(RETROFIT) F. PAGING SYSTEM CABLING SHALL HAVE AN INDEPENDENT PATHWAY AND SHALL NOT BE RUN IN CERTIFIED INSTALLER AT A PLUS TIER(CIP,CIP-GOLD,CIP-PLATINUM,OR 6. ANALOG WALL PHONE MODULAR FACEPLATES SHALL BE STAINLESS STEEL. FURNISH CABLE BUNDLES PENETRATING GYPSUM OR MASONRY WALLS,THE FOLLOWING PRODUCTS TERMINATION METHODS DESCRIBED WITHIN CONTRACT DOCUMENTS SHALL BE PROJECT TYPE PHAFSAACY CCT - MULTI-SITE/NATIONAL)AND OASIS CERTIFIED.THE TELECOMMUNICATIONS CONTRACTOR AND INSTALL: ARE ACCEPTABLE: CABLE TRAY OR OTHER SYSTEM PATHWAYS AND SHALL CONFORM TO THE CABLE PATHWAY REDRESSED OR REMOVED AND REPLACED AS REQUIRED AT THE DIRECTION OF THE IT STANDARDS HEREIN. CONSULTANT AND CONSTRUCTION MANAGER. DEAL TYPE PPR RESPONSIBLE FOR WORKMANSHIP AND INSTALLATION PRACTICES IN ACCORDANCE A FACEPLATE FOR WALL-PHONE OUTLETS;ALLENTEL PART NO.AT630A G. WHERE CABLE QUANTITIES EXCEED THE CAPACITY OF ONE ROW OF"J HOOKS', WITH THE ORTRONICS CERTIFIED INSTALLER PROGRAM(CIP).THE CERTIFIED 1. HILTI FIRESTOP RETROFIT SLEEVE KIT(CFS-SL RK)FQR SLEEVED OPENINGS EQUAL TO SUBCONTRACTOR SHALL INSTALL EITHER MULTIPLE ROWS OF"J HOOKS°OR TRAPEZE-TYPE F. CABLE SEPARATION DISTANCES - CONTRACTOR SHALL HAVE 30%QF THEIR TECHNICIANS TRAINED ON COPPER&FIBER 7. WALL PHONE FACEPLATES SHALL BE STAINLESS STEEL.FURNISH AND INSTALL: OR LESS THAN 4"DIAMETER. CABLE SUPPORTS. 1. SUBCONTRACTOR SHALL COORDINATE WITH OTHER TRADES TO ASSURE CABLES ARE INSTALLATIONS AND TESTING BY ORTRONICS;THEY ALSO SHALL HAVE AT LEAST 1 A ORTRONICS OR-403STJWP TRACJACK FACEPLATE WITH STUDS 2. HILTI FIRESTOP CABLE COLLAR(CFS-CC)FOR UN-SLEEVED OPENINGS EQUAL TO OR HW H. SUBCONTRACTOR SHALL REVIEW CABLE ROUTING AND SUPPORT METHODS WITH THE B W CT a�as369 PROJECT MANAGER SUCCESSFULLY COMPLETE AN ORTRONICS 2-DAY MANAGEMENT ENGINEERS CONSULTANTS FIELD ENGINEER AND GENERAL CONTRACTOR BEFORE ORDERING ROUTED TO ASSURE COMPLIANCE WITH THE MINIMUM SEPARATION DISTANCES AS • CERTIFICATION CLASS.ORTRONICS WILL EXTEND A 25-YEAR STATIC,DYNAMIC AND B SINGLE 8-PIN MODULAR JACK WITH T-568B WIRING(BLACK);ORTRONICS PART NO. LESS THAN 4"DIAMETER. MATERIAL_ DESCRIBED HEREIN. APPLICATIONS WARRANTY TO THE END USER. OR-TJ600-00 3. HILTI FIRESTOP BLOCK(CFS-BL)FOR OPENINGS LARGER THAN 4"DIAMETER. 3.07 EQUIPMENT RACKS 2. ALL CABLING SHALL BE AT LEAST:12"FROM HIGH VOLTAGE LIGHTING AND _ B. PRODUCT WARRANTY 8. CEILING-MOUNTED CAMERA AND WIRELESS/NETWORK ACCESS POINT BOXES. FURNISH 2.10 LABELING PRODUCTS A. EQUIPMENT RACKS AND CABINETS SHALL BE BOLTED TO EACH OTHER AND RACKS SHALL BE FLUORESCENT FIXTURES UNLESS WITHIN A METAL ENCLOSURE,72"FROM ARCHITECT OF RECORD 1. THE MANUFACTURER OF PASSIVE TELECOMMUNICATIONS EQUIPMENT USED IN A AND INSTALL: A. ALL COMMUNICATIONS CABLING LABELS SHALL MEET THE LEGIBILITY,DEFACEMENT, EQUIPPED WITH VERTICAL CABLE MANAGEMENT CAGES BETWEEN AND AT EACH END OF EACH TRANSFORMERS AND MOTORS. MANNER NOT ASSOCIATED WITH THE SYSTEMS WARRANTY MUST HAVE A MINIMUM FIVE A FACEPLATE FOR CAMERA AND WIRELESS/NETWORK ACCESS POINT BOXES; EXPOSURE AND ADHESION REQUIREMENTS OF UL 969. RACK. EACH EQUIPMENT RACK SHALL BE BOLTED DIRECTLY TO THE SLAB. EQUIPMENT RACKS 3. MINIMUM SEPARATION DISTANCES BETWEEN PATHWAYS AND POWER WRING OF 480 (5)YEAR COMPONENT WARRANTY ON ALL PRODUCTS. THE PRODUCTS WARRANTY ORTRONICS PART NO.OR 404TJ2. B. SHALL BE PRINTED OR COMPUTER PRINTED TYPE.HAND WRITTEN LABELS OF ANY KIND ARE WILL BE ASSEMBLED AND INSTALLED FLUSH,PLUMB,AND SQUARE. VOLTS OR LESS ARE SHOWN IN THE FOLLOWING: COVERS THE COMPONENTS AGAINST DEFECTS IN MATERIAL OR WORKMANSHIP UNDER UNACCEPTABLE AND SHALL BE REPLACED BY THE CONTRACTOR AT NO ADDITIONAL COST TO B. EACH EQUIPMENT RACK SHALL BE GROUNDED DIRECTLY THE GROUNDING BUSBAR PROVIDED NORMAL AND PROPER USE. B PATCH CORD FOR CAMERA AND WIRELESS ACCESS POINT;ORTRONICS PART NO. THE CUSTOMER. BY THE ELECTRICAL CONTRACTOR. ATTACHMENT(S)TO THE GROUNDING BUSBAR AND OR-MC603-05 HORIZONTAL GROUNDING KIT SHALL BE ACCOMPLISHED WITH ILS AWG(MINIMUM)INSULATED C. APPLICATIONS SUPPORTED C. PROVIDE A VINYL SUBSTRATE WITH A WHITE PRINTING AREA AND BLACK PRINT.IF CABLE CONDUCTOR WIRE WITH A TWO-HOLE(2-HOLE)COMPRESSION CONNECTOR(S). GROUNDING 1_ EXISTING AND FUTURE APPLICATIONS SUPPORTED FOR A CHANNEL MODEL WARRANTY 2.07 SECURITY CABLES JACKET IS WHITE,PROVIDE CABLE LABEL WITH YELLOW OR ORANGE PRINTING AREA SO WILL COMPLY WITH THE REQUIREMENTS OF IEC 1000-5-2,ANSI/TIA/EIA-607. SEPARATION OF TELECOMMUNICATIONS INCLUDE THOSE APPROVED BY THE INSTITUTE OF ELECTRONIC AND ELECTRICAL LABELS ARE EASILY DISTINGUISHABLE. 3.08 CABLE MANAGEMENT HARDWARE PATHWAYS FROM<=480V POWER LINES A. FURNISH AND INSTALL ALL CABLE NECESSARY TO PROVIDE A COMPLETE A FULLY D. SHALL BE FLEXIBLE VINYL OR OTHER SUBSTRATES TO APPLY EASY AND FLEX AS CABLES ARE ENGINEERS(IEEE),THE ASYNCHRONOUS TRANSFER MODE(ATM)FORUM,THE OPERATIONAL SYSTEM. BENT. A. VERTICAL CABLE MANAGEMENT CAGE SHALL BE INSTALLED BETWEEN AND AT EACH END OF MINIMUM SEPARATION AMERICAN NATIONAL STANDARDS INSTITUTE(ANSI)OR THE INTERNATIONAL B. ALL CABLE SHALL BE PLENUM RATED. E. SHALL USE AGGRESSIVE ADHESIVES THAT STAY ATTACHED TO ALL JACKET TYPES. EACH RACK. ADJACENT RACKS SHALL BE BOLTED TOGETHER. DISTANCE CONDITION <2 KVA 2-5 KVA 2-5 KVA ORGANIZATION OF STANDARDS(ISO)THAT SPECIFY COMPATIBILITY WITH THE CABLE C. APPROVED CABLE MANUFACTURER: F. PROVIDE LABELS BY BRADY CORPORATION AS FOLLOWS:NOTE: ANY"OR 3.09 CABLE TERMINATION AND BLOCKS ' REFERENCED HEREIN.ADDITIONAL APPLICATIONS THAT ARE COVERED BY THIS 1. TAPPAN OR AN EQUAL BELDEN OR WINDY CITY CABLE-NO SUBSTITUTES. EQUAL"SUBSTITUTIONS MUST BE APPROVED IN ADVANCE BY THE OWNER. UNSHIELDED POWER LINES 127 MM 305 MM 610 MM WARRANTY INCLUDE THOSE UNDER DEVELOPMENT FOR USE ON THE TYPE OF CABLING 1. HORIZONTAL.CABLE LABELS A. LOCATION AND PLACEMENT OF ALL TERMINATION AND DISTRIBUTION HARDWARE SHALL BE AS OR ELECTRICAL EQUIPMENT SPECIFIED IN THIS BID PACKAGE WHICH INCLUDES,GIGABIT ETHERNET(IEEE 802.3Z, 2- INSTALLER SHALL UTILIZE A COMPOSITE CABLE WHEREVER PRACTICABLE. THE REFLECTED ON THE DRAWINGS. IN PROXIMITY TO OPEN OR (5 IN) (12 IN) (12 IN) 802.3AB)AND 622 MB/S ATMA TWENTY-FIVE(25)YEAR NETCLEAR WARRANTY FOR THE INDIVIDUAL OR COMPOSITE CABLE SHALL CONSIST OF THE PART NUMBERS IDENTIFIED A 4 PAIR UTP TLS2200 LABELS-PTL-31-427 OR EQUAL B. PATCH PANELS SHALL BE SECURELY INSTALLED ON THE EQUIPMENT RACK RAILS WITH FOUR NON-METAL PATHWAYS IDF CABLING SYSTEMS SHALL BE PROVIDED FOR AN END-TO-END CHANNEL MODEL UNDER"PHYSICAL SECURITY CABLE"HEADING BELOW. SCREWS PER PANEL. POSITIONS OF ALL PATCH PANELS SHALL FOLLOW POSITIONS AND B 12 TO 24 STRAND FIBER TLS2200 LABELS-PTL-2127 OR EQUAL DIMENSIONS SHOWN ON DRAWINGS- UNSHIELDED POWER LINES 152 MM 305 MM INSTALLATION WHICH COVERS APPLICATIONS ASSURANCE,CABLE,CONNECTING 3. PHYSICAL SECURITY CABLE PART NUMBERS C. ONE STRAIN-RELIEF BAR SHALL BE INSTALLED BEHIND EACH EQUIPMENT RACK MOUNTED OR ELECTRICAL EQUIPMENT 64 MM 2. 48 TO 96 STRAND FIBER TLS2200 LABELS-PTL-33-427 OR EQUAL BACKBONE LABELS' HARDWARE AND THE LABOR COST FOR THE REPAIR OR REPLACEMENT. THIS WARRANTY WILL COVER EITHER COPPER CABLING SYSTEM,FIBER CABLING SYSTEM,OR A STANDARD DISTANCE: COPPER PATCH PANEL. SUBCONTRACTOR SHALL UTILIZE HOOK AND LOOP STYLE WRAPS(I.E. IN PROXIMITY TO GROUNDED (6 IN) (12 IN) A 4 PAIR UTP TLS2200 LABELS-PTL-31-427 OR EQUAL VELCRO)TO SECURE THE CABLING TO THE STRAIN RELIEF BAR,TAKING CARE NOT TO CRIMP METAL CONDUIT PATHWAY (2.5 IN) BOTH,DEPENDING ON WHICH IS/ARE SELECTED FOR INSTALLATION. 1) RISER RATED TAPPAN PART NUMBERS:2260AB3M+1880AB4M+2280AB4M+ THE CABLE. B 12 TO 24 STRAND FIBER TLS2200 LABELS-PTL-21-427 OR EQUAL POWER LINES ENCLOSED IN A 1.41 ACCEPTANCE 2280AB4M/CMR;WHERE CARD READER(3 PR.22 AWG,OA SHIELD),LOCK D. ALL FIBER PATCH PANELS SHALL BE FULLY POPULATED WITH THE SPECIFIED COUPLER PANEL GROUNDED METAL CONDUIT 76 MM 152 MM CONSULTANT: ° POWER(4C,18 AWG,SHIELDED),DOOR CONTACT(4C,22 AWG,SHIELDED), C 48 TO 96 STRAND FIBER TLS2200 LABELS-PTL-33-427 OR EQUAL OR PANELS. ALL UNUSED PANEL SLOTS SHALL BE POPULATED WITH BLANK PANELS. (OR EQUIVALENT SHIELDING) ■ A. UPON RECEIPT OF THE CONTRACTOR'S DOCUMENTATION OF CABLE TESTING,THE REQUEST EXIT/SPARE(4C 22 AWG,SHIELDED) E. FUSION-SPLICE ALL FIBER OPTIC PIGTAILS PER SPECIFICATION TOLERANCES DEFINED HEREIN, IN PROXIMITY TO GROUNDED - (3 IN) (6 IN) OWNER/OWNER'S REPRESENTATIVE/CONSULTANT MAY REVIEW OR OBSERVE THE G. RACKS AND SERVER CABINETS 3.10 CABLE ROUTING INSTALLATION AND REQUEST RANDOM TESTS OF THE CABLES INSTALLED. THE NUMBER OF 2) PLENUM RATED TAPPAN PART NUMBERS:2260AB3M+1880AB4M+2280AB4M+ 1- RACKS SHALL BE LABELED AS SHOWN ON THE DRAWINGS. METAL CONDUIT PATHWAY CABLES SO RANDOMLY TESTED SHALL NOT EXCEED 5%OF THE TOTAL NUMBER OF CABLES 2280AB4M/CMP;WHERE CARD READER(3 PR.22 AWG,OA SHIELD),LOCK 2. CONTRACTOR SHALL GET OWNER/CONSULTANT APPROVAL OF LABELS AND LOCATION A. GENERAL: INSTALLED. ONCE THE TESTING HAS BEEN COMPLETED AND CLIENT AND ITS POWER(4C,18 AWG,SHIELDED),DOOR CONTACT(4C,22 AWG,SHIELDED), PRIOR TO LABELING ANY RACKS OR CABINETS. 1- ALL WORK SHALL BE DONE IN A WORKMANLIKE FASHION(SEE DEFINITION OF REPRESENTATIVES ARE SATISFIED THAT ALL WORK IS IN ACCORDANCE WITH THE CONTRACT REQUEST EXIT/SPARE(4C 22 AWG,SHIELDED) WORKMANLIKE IN PART I OF THIS DOCUMENT)OF THE HIGHEST STANDARDS- CABLES 3.11 BACKBONE CABLE INSTALLATION Qp�^ DOCUMENTS,THE OWNER'S REPRESENTATIVE WILL NOTIFY THE SUBCONTRACTOR THROUGH H. PATCH PANELS SHALL BE DRESSED IN A NEAT MANNER,OBSERVING CABLE BEND RADIUS LIMIT AT EACH Eng/nee S+ THE CONSTRUCTION MANAGER IN WRITING. B EXTENDED DISTANCE: A. GENERAL 1.42 QUALITY'ASSURANCE 1. PER THE MANUFACTURERS RECOMMENDED SIZE FOR LABELING PATCH PANEL PORTS. EQUIPMENT RACK AND ON LADDER RACKS AND CABLE TRAYS. 1. SUBCONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ASSURE THAT THE 1) RISER RATED TAPPAN PART NUMBERS:- 1860AB3M+16BQAB4M+1880AB4M+ PANELS SHALL HAVE ALL PORTS MACHINE LABELED, Consultants A. LADDER RACK SHALL BE OF UNIFORM QUALITY AND APPEARANCE AND MEET OR EXCEED THE 1880ABM/CMR;WHERE CARD READER(3 PR.18 AWG,OA SHIELD),LOCK POWER 2. ALL CABLING SHALL BE HANDLED,INSTALLED,AND TERMINATED IN ACCORDANCE WITH MAXIMUM TENSILE LOAD,MINIMUM BEND RADIUS,AND MAXIMUM VERTICAL RISE OF 2. PANELS SHALL BE LABELED IN ACCORDANCE WITH THE DRAWINGS WITH MACHINE THE MANUFACTURER'S INSTRUCTIONS. BACKBONE CABLES(FIBER AND COPPER)ARE NOT VIOLATED DURING OR AFTER FOLLOWING REQUIREMENTS', (4C,16 AWG,SHIELDED),DOOR CONTACT(4C,18 AWG,SHIELDED),REQUESTVIII@ GENERATED THERMAL PRINTED VINYL LABELS WITH LETTERING SIZE A MINIMUM OF 3/8 INSTALLATION. 1. NEC COMPLIANCE:COMPLY WITH NEC,AS APPLICABLE TO CONSTRUCTION AND EXIT/SPARE(4C 18 AWG,SHIELDED) INCHES TALL. COORDINATE FORMAT OF LABELING WITH ENGINEERIOWNER, 3. WITHIN THE MDF ROOM PROVIDE VELCRO CABLE TIES AT FIVE-FOOT INTERVALS FOR INSTALLATION OF CABLE TRAY AND CABLE CHANNEL SYSTEMS(ARTICLE 318,NEC). 2) PLENUM RATED TAPPAN PART NUMBERS:1860AB3M+1680A64M+1880A64M+ EACH CABLE BUNDLE. B. COPPER BACKBONE CABLE INSTALLATION 155 SEAPORT BOULEVARD PART 3- EXECUTION 1. CATEGORY 3 AND BACKBONE CABLES SHALL BE FIELD-TERMINATED ON WALL MOUNTED 2. NEPA COMPLIANCE COMPLY WITH NEPA 70B,"RECOMMENDED PRACTICE FOR 1880ABM/CMP;WHERE CARD READER(3 PR.18 AWG,OA SHIELD),LOCK 4. CABLES MUST BE SECURELY BUNDLED,BUT MAY NOT DISPLAY INSULATION/SHEATH 110 STYLE PANELS AS INDICATED ON DRAWINGS AND PANEL SCHEDULES. SEAPORT WEST, FLOOR 2 ELECTRICAL EQUIPMENT MAINTENANCE"PERTAINING TO INSTALLATION OF CABLE TRAY POWER(4C,16 AWG,SHIELDED),DOOR CONTACT(4C,18 AWG,SHIELDED), 3.01 WORKMANSHIP AND GENERAL REQUIREMENTS DAMAGE OR PAIR DISTORTION FROM OVER-TIGHTENING OF CABLE TIES BOSTON, MA 02210 SYSTEMS. REQUEST EXIT/SPARE(4C 18 AWG,SHIELDED) 3.12 HORIZONTAL CABLE INSTALLATION A. ALL WORK SHALL BE DONE IN A WORKMANLIKE FASHION(SEE DEFINITION OF WORKMANLIKE IN 5. IT IS THE RESPONSIBILITY OF THE SUBCONTRACTOR TO ATTEND DAILY OR WEEKLY P. 617.443.4950 • F. 617.443.4959 3. MANUFACTURER'S INSTALLATION GUIDELINES AND BEST PRACTICES. 3) INDIVIDUAL JACKETS FOR EACH CABLE: PART I OF THIS DOCUMENT)OF THE HIGHEST STANDARDS IN THE TELECOMMUNICATIONS CONSTRUCTION COORDINATION MEETINGS TO ASSURE COMPLIANCE WITH ALL CABLE A. SUBCONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ASSURE THAT THE INDUSTRY. ALL EQUIPMENT AND MATERIALS ARE TO BE INSTALLED IN A NEAT AND SECURE ROUTING CRITERIA IDENTIFIED HEREIN. NO ADDITIONAL COST SHALL BE INCURRED BY MAXIMUM TENSILE LOAD,MINIMUM BEND RADIUS,AND CABLE MANUFACTURERS'GUIDELINES 4. NEMA COMPLIANCE: COMPLY WITH NEMA STANDARDS PUBLICATION NUMBER VE1, • CARD-ORANGE WITH COLOR CODE-3PR BLACK,RED/WHITE,GREEN/ MANNER,WHILE CABLES ARE TO BE PROPERLY DRESSED. ANY WORK DEEMED TO BE ARE NOT VIOLATED DURING OR AFTER INSTALLATION. THE OWNER,ENGINEER,OR CONSTRUCTION MANAGER DUE TO LACK OF COORDINATION "CABLE TRAY SYSTEMS". ORANGE,BROWN NON-COMPLAINT WITH THIS REQUIREMENT SHALL BE IMMEDIATELY REPLACED AT NO B. THE INSTALLATION OF ALL CABLING INSTALLED UNDER THIS SECTION SHALL BE EXECUTED IN ->•,,°"e,�„".,"•=a--•A•,. ON THE PART OF THE SUBCONTRACTORS. DEVELOPER: ADDITIONAL COST TO OWNER AND WITHOUT DISRUPTION TO PROJECT SCHEDULES. WORK ACCORDANCE WITH INDUSTRY STANDARD PRACTICES AND MEETING THE CODES AND 5- UL .PROVIDE PRODUCTS THAT ARE UL-CLASSIFIED AND LABELED. • LOCK-GRAY CLOSELY WITH ON-SITE ENGINEER(WB ENGINEERS I CONSULTANTS)TO ASSURE COMPLIANCE 6. ALL WIRE AND/OR CABLE SHALL BE SECURELY SUPPORTED. ALL SUPPORTING REQUIREMENTS OF ALL AUTHORITIES HAVING JURISDICTION. THE WORK SHALL FULLY • • DOOR-WHITE AND TO PROACTIVELY ADDRESS ANY QUESTIONS OR CONCERNS IN THIS REGARD. HARDWARE AND FASTENERS SHALL BE OF TYPE AND DESIGN APPROVED FOR THE CONFORM TO CURRENT NEC REQUIREMENTS AND EIAITIA GUIDELINES. B. ALL TERMINATIONS,CABLE MANAGEMENT,CABLE SUPPORTS,AND RACKING METHODOLOGIES INTENDED USE,SIZE,AND WEIGHT LOADING. SUBCONTRACTOR SHALL ENSURE C. HORIZONTAL WORK STATION CABLES SHALL RUN DIRECTLY AS"HOME RUNS"TO THE POINT OF PART 2- PRODUCTS • REX/SPARE-BLUE COLOR CODE FOR LOCK,DOOR&REX/SPARE- BLACK, SHALL BE CONSISTENT THROUGHOUT THE ENTIRE PROJECT AND ALL CABLE SHALL BE TERMINATION AS REFLECTED IN THE DRAWINGS AND ASSIGNED IN THE CABLE PULLING COMPLIANCE WITH THE FOLLOWING GUIDELINES', 2.01 QUALITY ASSURANCE RED,WHITE,GREEN DRESSED IN ACCORDANCE WITH MANUFACTURER REQUIREMENTS AND APPROVED BY THE SCHEDULES. ALL CABLES SHALL BE CONTINUOUS RUNS WITHOUT SPLICES BETWEEN ANY OWNER AND ENGINEER. SUBCONTRACTOR SHALL PROACTIVELY COORDINATE A CABLE SHALL NOT BE PERMITTED TO REST ON CEILING TILES OR CEILING TILE TWO TERMINATIONS OR END POINTS. D. SERVICE LOOPS: A. ALL MATERIALS USED SHALL BEAR THE UNDERWRITERS'LABORATORY,INC.LABEL,PROVIDED SUPPORT GRIDS,AND SHALL NOT BE FASTENED TO POWER CONDUITS OR PIPES OF D. THE MAXIMUM HORIZONTAL DISTANCE SHALL BE 90M(295 FT.),INDEPENDENT OF MEDIA TYPE 1. PROVIDE 5 METERS MINIMUM SLACK AT JUNCTION BOX ADJACENT TO CONTROL PANELS METHODOLOGIES ACCORDINGLY. A STANDARD HAS BEEN ESTABLISHED FOR THE MATERIAL IN QUESTION. C. ALL DEVICES SHALL BE INSTALLED FLUSH,PLUMB,LEVEL AND SQUARE. (CP) ANY KIND, WHERE: S. ALL PRODUCTS AND MATERIALS SHALL BE NEW AND UNUSED,CLEAN,FREE OF DEFECTS, D. PROTECT ALL CABLE AND MATERIALS BEFORE,AFTER,AND DURING INSTALLATION. 1. 90M(295 FT)IS THE TOTAL CABLE LENGTH FROM THE POINT OF TERMINATION IN THE TR DAMAGE,AND CORROSION. B CABLES SHALL NOT BE ROUTED IN SUCH A FASHION AS TO OBSTRUCT ACCESS 2. PROVIDE 5 METERS MINIMUM SLACK COILED WITHIN CABLE PULL BOX(JB)ADJACENT TO E. CLEAN AND REMOVE ALL DEBRIS. TO THE POINT OF TERMINATION AT THE INFORMATION OUTLET. 2.02 EQUIPMENT AND MATERIALS-MINIMUM REQUIREMENTS HATCHES,DOORS,UTILITY ACCESS PANELS,AND MECHANICAL SERVICE FITTINGS CARD READER LOCATION. HOWEVER,ADDITIONAL CABLE SLACK MAY BE REQUIRED IF F. EXAMINE AND COMPARE THE TELECOMMUNICATIONS CABLING DRAWINGS AND OR WORK AREAS. 2. ALL HORIZONTAL CABLING PATHWAYS HAVE BEEN COORDINATED AND IDENTIFIED ON A. THE MANUFACTURERS AND PRODUCTS SPECIFIED IN THE DOCUMENT ARE TO BE USED . NO THE CABLE PULL BOX IS NOT LOCATED REASONABLY CLOSE TO THE CORRESPONDING SPECIFICATIONS WITH THE DRAWINGS AND SPECIFICATIONS OF OTHER TRADES;REPORT ANY C CABLING SHALL NOT BE ROUTED THROUGH VENTILATING SHAFTS OR GRATES,FIRE THE DRAWINGS, PRIOR TO INSTALLING CABLE THE SUBCONTRACTOR SHALL VERIFY SUBSTITUTIONS OF COMPONENTS SPECIFICALLY REFERENCED WILL BE ALLOWED,WITHOUT DOOR. IN THIS SCENARIO,AS A RULE,PROVIDE CABLE SLACK LENGTH EQUAL TO THE DISCREPANCIES TO THE GENERAL CONTRACTOR AND ENGINEER. OBTAIN WRITTEN INSTRUCTIONS FOR NECESSARY REVISIONS IN THE PROJECT APPROACH_ DOORS,OR PARALLEL WITH ELECTRICAL CONDUCTORS,EXCEPT AS NOTED IN THAT NO RUN WILL EXCEED 90 METER MAXIMUM LENGTH REQUIREMENT. PRIOR WRITTEN OWNER CONSENT AFTER SUBMITTAL REVIEW. DISTANCE FROM THE CABLE PULL BOX TO THE CORRESPONDING DOOR,PLUS 3 METERS APPLICABLE NEC ARTICLES AND EIA/TIA STANDARDS(SEE NEC ARTICLE BOG AND G. ALL CABLES SHALL BE DRESSED IN A NEAT MANNER,OBSERVING CABLE BEND RADIUS LIMITS B. ALL PRODUCTS AND MATERIALS SHALL BE NEW,CLEAN,FREE OF DEFECTS AND FREE OF ANSIIEIA/TIA STANDARD 569 FOR ADDITIONAL ROUTING REQUIREMENTS). 3. THE SUBCONTRACTOR SHALL BE HELD RESPONSIBLE FOR OUTLETS TESTING LONGER E. FOR RS-485 COMMUNICATION BETWEEN THE CONTROL PANELS AND COMPUTER SERVER AT ALL TIMES. CABLE INSULATION SHALL BE PROTECTED AT ALL TIMES. CABLES WITH DAMAGE AND CORROSION. UTILIZE PLENUM RATED: DAMAGED SHEATHS SHALL BE REPLACED AT NO ADDITIONAL COST TO OWNER. D WHERE A CONFLICT IN STANDARDS AND CODES ARISES,THE MORE STRINGENT THAN 90 METERS,IF PATHWAYS WERE NOT COORDINATED WITH WB ENGINEERS G. ALL PRODUCTS INSTALLED WILL MEET OR EXCEED THE MINIMUM PERFORMANCE 1. COORDINATE CABLING REQUIREMENTS WITH IT CONTRACTOR. H. NO MORE INSULATION THAN IS NEEDED TO TERMINATE THE CABLE iN THIS POSITION SHALL BE SHALL GOVERN. CONSULTANTS FIELD ENGINEER PRIOR TO INSTALLATION. REQUIREMENT AS LISTED IN THE TECHNICAL SPECIFICATION OF THIS DOCUMENT AND ITS E THE SUBCONTRACTOR SHALL ROUTE ALL TELECOMMUNICATIONS CABLING IN E. THE SUBCONTRACTOR SHALL ASSURE THAT MANUFACTURER AND TIAIEIA RECOMMENDED ■ STRIPPED FROM THE CABLE. INDIVIDUAL.PAIRS SHALL MAINTAIN THE MAXIMUM ATTAINABLE CORRESPONDING ADDENDA- 2. UL LISTED,NEC TYPE CMP RATED APPROVED PATHWAYS: TWIST INTEGRITY AT THE TERMINATION POINT. BEND RADIUS WILL BE MAINTAINED DURING AND AFTER INSTALLATION. D. NO SUBSTITUTION OF PRODUCTS OR SERVICES WILL BE ACCEPTED WITHOUT PRIOR 3. 2-CONDUCTOR STRANDED(16 X30)18 AWG. I. WORK DEEMED NOT TO CONFORM TO THE CABLE DRESSING AND TERMINATION METHODS 1) SUITABLE METHODS OF SUPPORT INCLUDE CABLE TRAY,LADDER RACK,AND F. SUBCONTRACTOR SHALL ASSURE PULLING TENSION IS MONITORED TO ENSURE THAT • APPROVAL FROM BOTH OWNER AND THE MANUFACTURER PROVIDING THE APPLICATION DESCRIBED WITHIN CONTRACT DOCUMENTS AND THESE SPECIFICATIONS SHALL BE J-HOOK SYSTEMS SECURELY FASTENED TO BUILDING CONSTRUCTION. MANUFACTURER-RECOMMENDED TENSILE RATINGS ARE NOT EXCEEDED. WARRANTY. 4. OVERALL SHIELD REDRESSED OR REMOVED AND REPLACED AS REQUIRED AT THE DIRECTION OF THE OWNER 2.03 WORKSTATION COPPER TERMINATION PATCH PANELS AND/DR THE ENGINEER AT NO ADDITIONAL COST TO THE OWNER. 2) CABLING SHALL BE CONCEALED AND ROUTED IN CABLE TRAY,CONDUITS, G. CABLE ENDS AND CONNECTORS SHALL BE PROTECTED WITH CAPS AT ALL TIMES,EXCEPT 5. NOMINAL OUTSIDE DIAMETER:4.0 MM. POKE-THROUGH FITTINGS,AND FURNITURE SYSTEMS IN A NEAT AND DURING PULLING OPERATION. A. APPROVED MANUFACTURER: 3.02 SPECIAL TOOLS PROFESSIONAL MANNER. H. HORIZONTAL CABLING WILL BE ROUTED ON LADDER RACKS WITHIN THE MDF.IN THE MDF 1_ ORTRONICS 6. PROVIDE 5 METERS MINIMUM SLACK AT JUNCTION BOX ADJACENT TO CONTROL PANELS ROOM INTRA-ROW CABLING SHALL BE ROUTED DIRECT TO EACH CABINET FROM THE RACKS IN A. CRAFT PERSONNEL WILL BE REQUIRED TO PROVIDE AND USE THE PROPER TOOLS AND TEST ROW ALONG THE OUTSIDE EDGE(REAR OF CABINET)OF THE LADDER RACK. (CP). 7. WHERE NO CABLE TRAY EXISTS,CABLES SHALL BE NEATLY VELCRO WRAPPED AND B. COPPER TERMINATION PATCH PANELS SHALL BEA 19"RACK MOUNTABLE 8-PIN(RJ45) EQUIPMENT IN THE PERFORMANCE OF EACH ACTIVITY. THE TOOLS MUST BE IN GOOD SUSPENDED WITH THE APPROPRIATE HANGERS AND SHALL NOT BE ALLOWED TO REST MODULAR JACK PANEL EQUIPPED WITH 6 PORT MODULES. THE IDC CONNECTION ON THE 7. ALL CABLES MUST BE RUN IN CONDUIT. WORKING ORDER,AND THE TEST EQUIPMENT MUST HAVE CURRENT CALIBRATION I. CABLES LEAVING LADDER RACK OR SLEEVES SHALL BE SUPPORTED ABOVE CEILINGS USING REAR OF THE PANEL HOUSES A PRINTED CIRCUIT BOARD THAT PROVIDES CONTINUOUS CERTIFICATES,AS APPLICABLE. ON DUCTS,PIPES AND CONDUITS. AT NO TIME WILL CABLE BE SUPPORTED FROM HUNG "J'HOOKS SECURELY FASTENED TO CONSTRUCTION ABOVE CEILINGS BETWEEN LADDER F. FOR COMMUNICATION BETWEEN NETWORK DEVICES UTILIZE PLENUM RATED CATEGORY 6E AS CEILINGS OR CEILING SUPPORT WIRES. RACKS OR CABLE TRAYS AND POINTS OF VERTICAL TRANSITION DOWN TO WORK AREAS. CONNECTION TO THE 8-PIN MODULAR JACKS ON THE FRONT. THE PANEL SHALL BE CATEGORY SPECIFIED IN THE INFORMATION TECHNOLOGIES SPECIFICATION. ALL NETWORK CAMERA B. CLIENT AND THE CONSTRUCTION MANAGER RESERVE THE RIGHT TO REVIEW THE TOOL AND 6 COMPLIANT AND BE CAPABLE OF HANDLING TINEIA T-568(B)WIRING PIN-OUT. FURNISH AND TEST EQUIPMENT LISTS AND MAINTENANCE PROCEDURES OF THE SUBCONTRACTOR. B. CABLE SHEATH PROTECTION J"HOOKS SHALL BE INSTALLED ON MAXIMUM FIVE-FOOT CENTERS,AND CONFIGURED SUCH CABLING AND PATCH CABLES ARE INSTALLED UNDER A SEPARATE CONTRACT BY THE IT THAT CABLE SPANS DO NOT REST ON POWER AND LIGHTING DISTRIBUTION OR ON CEILINGS. INSTALL: 3.03 STORAGE AND PROTECTION OF MATERIALS CONTRACTOR. 1. CONTRACTOR SHALL PROTECT CABLE SHEATHS BY INSTALLING APPROPRIATE PLASTIC WHEN USING HOOKS,NO MORE THAN 50%OF THE USABLE AREA SHALL BE FILLED, 1. 48-PORT CATEGORY 6 UTP PATCH PANEL(S)-2 RMU ORTRONICS PART NO.OR-PHD66U48 1. PATCH CORDS: A. THE SUBCONTRACTOR SHALL ARRANGE AND COORDINATE ALL ACCESS TO THE JOB SITE(IDF) GROMMETS PRIOR TO PULLING CABLE. J. ALL HORIZONTAL DISTRIBUTION CABLING FEEDING FURNITURE SYSTEMS RACEWAYS OR 2.04 COPPER UTP CABLE-FACILITY AND TO THE BASE BUILDING DOCK,AS WELL AS THE RECEIPT,STAGING,MARSHALING,AND COUNTERTOP RACEWAYS SHALL BE ENCLOSED IN 1 Y;CONVOLUTED TUBING FROM POINT OF A PATCH CORDS SHALL BE OF THE SAME RATING AND MANUFACTURER AS THE UTP A WHERE IT IS NECESSARY TO PASS THROUGH A METAL STUD AND NO CONDUIT IS SAFE STORAGE OF ALL MATERIALS,TOOLS AND SUPPLIES WITH A PERSON SPECIFIED BY EXIT FROM CONDUIT STUB OR POKE THROUGH FITTING TO ENTRY POINT INTO RACEWAY. A. APPROVED MANUFACTURERS-BERK-TEK AND SUPERIOR ESSEX CABLINGS SYSTEMS GENERAL CONTRACTOR OR CONSTRUCTION MANAGER. THE BASE BUILDING IS OCCUPIED AND SUPPLIED(COORDINATE WITH ELECTRICAL DRAWINGS AND SPECIFICATIONS) K. ALL HORIZONTAL DISTRIBUTION CABLING FEEDING DESKTOP SURFACE MOUNT OUTLETS SHALL B. HORIZONTAL CABLE B COORDINATE PATCH CORDS LENGTHS WITH IT CONTRACTOR- "OFF-LIMITS"TO CONSTRUCTION PERSONNEL. UTILIZE A METAL STUD PUNCH AND EASY SNAP GROMMET BY ERICO OR APPROVED BE ENCLOSED IN'/."CONVOLUTED TUBING FROM POINT OF EXIT FROM CONDUIT STUB OR POKE ' C PATCH CORD CABLE MANAGEMENT: B. ALL MATERIAL DELIVERIES,EITHER BEFORE OR AFTER NORMAL WORKING HOURS,SHALL BE EQUAL. THROUGH FITTING TO ENTRY POINT INTO THE OUTLET- : 1. 4-PAIR CATEGORY 6+CABLES CONSIST OF NOMINAL 23 AWG COPPER CONDUCTORS 1) NEATLY COIL PATCH CABLE SLACK AND SECURE WITH PLENUM RATED VELCRO INCLUDED IN THIS PRICING. B PRIOR TO PULLING CABLE THROUGH CONDUIT FURNISH AND INSTALL PLASTIC OR 3.13 WORK AREA OUTLETS REVISIONS INSULATED WITH FEP COVERED BY PLENUM-RATED SKIN, THE CABLE SHALL CONTAIN A C. MATERIAL SHALL BE STORED TO MANUFACTURERS'RECOMMENDATIONS AS A MINIMUM. RUBBER INSULATING BUSHINGS TO PROTECT CABLE SHEATH FROM SHARP EDGES, FIRE-RETARDANT SHEATH NECESSARY TO MEET NEC AND LOCAL CODE LOW-FLAME TYPE CABLE WRAPS. D. CABLE MUST BE STORED INA LOCATION PROTECTED FROM WEATHER OR VANDALISM. CABLE C. BACKBONE CABLE ROUTING A. WORK AREA OUTLETS SHALL BE PROVIDED WHERE INDICATED ON DRAWINGS,AND SHALL I SSU ED FOR BID-PERMIT 06.06.1 7 REQUIREMENTS FOR PLENUM CABLE APPLICATIONS. FURNISH AND INSTALL EITHER: 2) CABLE SLACK SHALL BE SUSPENDED FROM CABLE HANGERS OR SUPPORTS MAY BE STORED IN SUB-ZERO TEMPERATURE;HOWEVER INSTALLATION OF CABLE MUST FOLLOW INSTALLATION DETAILS SHOWN. 1. BACKBONE CABLING WILL BE ROUTED BETWEEN TELECOMMUNICATIONS CLOSETS B. TYPICAL INFORMATION OUTLETS OCCUR IN FURNITURE-MOUNTED,WALL-MOUNT,AND FLOOR SPECIFICALLY DESIGNED FOR THE INTENDED PURPOSE OF UTP CABLE OCCUR IN AN ENVIRONMENT NOT LESS THAN 32 DEGREES FAHRENHEIT AND NOT MORE THAN A LANMARK 1000 -4-PAIR CATEGORY 6 PLENUM-RATED CABLE( BLUE);BERK-TEK PART MANAGEMENT AND SHALL NOT BE SUPPORTED OR COME INTO CONTACT THE 140 DEGREES FAHRENHEIT. THROUGH CONDUIT OR CABLE TRAY PROVIDED BY THE ELECTRICAL CONTRACTOR. BOX MOUNTED CONFIGURATIONS,IN LOCATIONS AND QUANTITIES REFLECTED ON THE # NO.10032094E. ANY PROTECTION AGAINST VANDALISM WILL BEAT SUBCONTRACTOR EXPENSE AS WILL ANY REFER TO ELECTRICAL DRAWINGS FOR PATHWAY DETAILS. DRAWINGS. CEILING DECK, COSTS ASSOCIATED WITH REPLACEMENT OF STOLEN OR DAMAGED MATERIALS. 2. FIBER OPTIC CABLING SHALL BE INSTALLED WITH"CAUTION"LABELS EVERY 25 FEET. C. FURNITURE INFORMATION OUTLETS WILL BE INSTALLED IN A FACEPLATE MOUNTED IN THE M B SUPERIOR ESSEX-4-PAIR CATEGORY 6 PLENUM-RATED CABLE(BLUE);SUPERIOR MODULAR FURNITURE. G. MISCELLANEOUS EQUIPMENT AND HARDWARE,FURNISH AND INSTALL ALL F. DURING CONSTRUCTION THE SUBCONTRACTOR SHALL ASSURE THAT ALL FIBER OPTIC AND LABELS SHALL BE SELF-ADHESIVE VINYL TYPE WITH BLACK LETTERING ON AN ORANGE ESSEX PART NUMBER PART NO.66-246-2B 1. INTERCONNECT CABLING UTP CABLE IS PROTECTED FROM DAMAGE. DEPLOY PEDESTRIAN/LIFT TRAFFIC CONES ANDD. WALL INFORMATION OUTLETS WILL BE INSTALLED FLUSH WITHIN PARTITION WALLS. FLUSH C NOTE:FOR EXISTING FACILITIES MAINTAIN CABLE MANUFACTURER ALREADY WARNING TAPE TO PREVENT CONSTRUCTION PERSONNEL FROM STEPPING ON OR OTHERWISE OR YELLOW BACKGROUND.USE PANDUIT PVC-FOBY OR EQUAL. SINGLE-GANG PLATES WILL BE INSTALLED_ i2_ PLATES,TERMINAL BLOCKS,RACEWAY,AND OTHER CABLE MANAGEMENT HARDWARE CI INSTALLED,UNLESS IT IS NOT ONE OF THE SPECIFIED CABLES ABOVE. DAMAGING CABLES. CABLE SHALL NOT BE LEFT ON FLOOR OVERNIGHT AND SHALL BE NEATLY D. HORIZONTAL CABLE ROUTING E. FLOOR OUTLETS WILL BE INSTALLED WITHIN A FLOOR BOX PROVIDED BY OTHERS. 3. CRIMP TYPE CONNECTORS ARE PROHIBITED. ALL CONNECTIONS SHALL BE SOLDERED COILED AND PROPERLY SUSPENDED FROM STRUCTURE UTILIZING APPROPRIATE CABLE 1. HORIZONTAL CABLE PATHS WILL BE IN A"STREETS AND AVENUES"FORMAT(I.E.,CABLE SUBCONTRACTOR WILL PROVIDE HARDWARE REQUIRED TO ACCOMMODATE FITTING_ ORUSE TERMINAL STRIPS MANAGEMENT HARDWARE SPECIFICALLY DESIGNED FOR THE PURPOSE OF SUPPORTING ROUTING SHALL BE INSTALLED ORTHOGONAL TO APPLICABLE BUILDING LINES). F. WIRELESS ACCESS POINT OUTLETS SHALL BE INSTALLED ABOVE ACOUSTICAL CEILING SPACE O 2.05 PATCH CORDS-MDF AND WORKSTATION COMMUNICATIONS CABLE. WHEREVER POSSIBLE. WHEREVER ACOUSTICAL CEILING SPACE IS NOT AVAILABLE OR 4. RELAYS ETC. 3.04 PROTECTION OF WORK AND PROPERTY 2. HORIZONTAL CABLES WILL GENERALLY BE RUN ABOVE HUNG CEILINGS OR BELOW PRACTICAL,COORDINATE WITH OWNER/ENGINEER PRIOR TO INSTALLATION TO DETERMINE p A. CATEGORY 6 PATCH CORDS WHERE REQUIRED IN QUANTITIES OF 50 CORDS(1 BOX EZ PATCH) RAISED FLOORS- CABLES SHALL NOT BE FASTENED TO DUCTS,PIPES,CONDUITS OR THE MOST DESIRABLE LOCATION, N PER PATCH PANEL INSTALLED.SEE SECTION 3 FOR LABELING REQUIREMENTS. 5, ENCLOSURES,JUNCTION BOXES FOR ADDITIONAL EQUIPMENT(BATTERIES,ETC),IF A. THE SUBCONTRACTOR SHALL MAINTAIN AND PROTECT ALL EQUIPMENT,MATERIALS,AND ANY OTHER STRUCTURES. G. CABLE TERMINATION AND DRESSING B. THE CATEGORY 6 PATCH CABLES SHALL BE FOUR(4)PAIR 24 AWG STRANDED UTP,PVC IN NECESSARY. TOOLS FROM LOSS OR DAMAGE FROM ALL CAUSES AND AT ALL TIMES,WHILE 1_ ALL CABLES SHALL BE DRESSED IN A NEAT MANNER AND WORKMANLIKE MANNER; C.., COMPLETE, SYSTEM. . LENGTHS OF FIVE(5)AND SEVEN(7)FEET AND BLUE IN COLOR AS FOLLOWS: 6. TO ENSURE OPERATIONAL ACCESS CONTROL SUBCONTRACTOR HAS EQUIPMENT,PERSONNEL,OR WORK TO PERFORM ON SITE. 3. HORIZONTAL CABLES TO MODULAR FURNITURE WILL PRIMARILY BE ROUTED VIA • 1. CATEGORY 6 PATCH CORD-FIVE(5)FOOT(1 BOX 50 CORDS PER INSTALLED PATCHB. THE SUBCONTRACTOR SHALL BE RESPONSIBLE FOR THE RECEIPT,SAFE STORAGE AND ELECTRICAL CONTRACTOR PROVIDED CONDUIT OR"POWER POLES". OBSERVING CABLE BEND RADIUS LIMIT AT EACH WORKSTATION OUTLET. 6 ' PANEL) DELIVERY OF MATERIALS AND EQUIPMENT TO THE JOB SITE AND FOR COORDINATION OF SAME 4. HORIZONTAL CABLES TO WALL STUB-UPS WILL BE ROUTED OUT OF THE IDF'S VIA CA6LIr 2.08 CABLE HANGERS AND SUPPORTS WITH THE CO 2- NO MORE INSULATION THAN IS NEEDED TO TERMINATE THE CABLE IN THIS POSITION NSTRUCTION MANAGER. MATERIAL AND EQUIPMENT SUBJECT TO DAMAGE BY SHALL BE STRIPPED FROM THE CABLE. INDIVIDUAL PAIRS SHALL MAINTAIN TWIST A ORTRONICS PART NO.EZC605Q50 06 NATURAL ELEMENTS SHALL BE STORED IN A MANNER SUITABLY SHELTERED FROM THE TRAY AND THEN ON J-HOOKS ABOVE THE PLENUM CEILING TO SELECTED WALL FEED INTEGRITY TO WITHIN.5"(ONE HALF-INCH)OF THE TERMINATION POINT_ C 2. CATEGORY 6 PATCH CORD-SEVEN(7)FOOT(1 BOX 50 CORDS PER INSTALLED PATCH A. J-HOOK CABLE HANGER AND SUPPORT COMPONENTS SHALL BE FURNISHED AND INSTALLED IN ELEMENTS BUT READILY ACCESSIBLE FOR INSPECTION OR IN A WEATHER-TIGHT ENCLOSURE LOCATION OR FED TO AS INDICATED ON DRAWINGS. p SUFFICIENT QUANTITIES TO ROUTE ALL TELECOMMUNICATIONS CABLING NOT IN UNDER SUPPLIED BY THE SUBCONTRACTOR. 3. AT LEAST 12"OF SLACK SHALL BE LEFT AT EACH INFORMATION OUTLET AFTER THE PANEL) 5. THE BIDDER SHALL REFER TO THE"TELECOMMUNICATIONS PLAN"SERIES OF DRAWINGS FLOOR CABLE TRAY AS SHOWN ON DRAWINGS. C. THE SUBCONTRACTOR SHALL NOT STORE OR PLACE MATERIAL ON FLOORS IN EXCESS OF THE INSTALLATION OF JACKS AND INSERTS. SLACK SHALL BE NEATLY COILED IN THE HUNG A ORTRONICS PART NO.EZC607Q50-06 B. J-HOOK CABLE SUPPORTS SHALL PROVIDE A BEARING SURFACE OF SUFFICIENT WIDTH TO FLOORS'DESIGNED LOAD LIMITS, WHERE ELECTRICAL CONTRACTOR PROVIDED CABLE TRAYS ARE INDICATED. CEILING. SLACK REQUIREMENTS FOR NON-FIXED OUTLET BOX LOCATIONS SHALL BE DRAWING BY: COMPLY WITH REQUIRED BEND RADII OF HIGH-PERFORMANCE CABLES;UL LISTED. E C.CATEGORY 5E PATCH CORDS 3.05 FIRE STOPPING 6. THE SUBCONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING PROPER FILL RATIOS INDICATED ON DRAWINGS. O C. J-HOOK CABLE SUPPORTS SHALL HAVE FLARED EDGES TO PREVENT DAMAGE WHILE TO COMPLY WITH EIAITIA RECOMMENDATIONS AND ALL APPLICABLE CODES. C 1. CATEGORY 5E PATCH CORDS WHERE REQUIRED IN QUANTITIES AS REQUIRED BY THE INSTALLING CABLES- A. COORDINATE FIRE STOPPING REQUIREMENTS WITH GENERAL CONTRACTOR. 4. AT LEAST 20 FEET OF SLACK SHALL BE LEFT AT ALL WAP OUTLETS AFTER INSTALLATION DATE: June 06, 2017 D. J-HOOK CABLE SUPPORTS SIZED 1 5116"AND LARGER SHALL HAVE A CABLE RETAINER STRAP B. PROVIDE FIRE-RESISTANT SILICONE FOAM FILL TO RESTORE FIRE RATINGS TO ALL WALL OR 7. ALL HORIZONTAL DISTRIBUTION CABLING FEEDING FURNITURE SYSTEMS RACEWAYS OF JACKS AND INSERTS.SLACK SHALL BE NEATLY COILED AND SECURED TO IMMEDIATE .v SPECIFIC DESIGN. TO PROVIDE CONTAINMENT OF CABLES WITHIN THE HANGER. THE CABLE RETAINER STRAP FLOOR OR CEILING PENETRATIONS. FOAM MUST BE UL CLASSIFIED AND MEET NEC AND LOCAL AND COUNTERTOP RACEWAYS SHALL BE ENCLOSED IN 1 '/."CONVOLUTED TUBING,PVC STRUCTURE OR OTHER USING VELCRO STRAPS OR TIES- 'cSHALL BE REMOVABLE AND REUSABLE AND BE SUITABLE FOR USE IN AIR HANDLING SPACES. CODE. MESH WRAP OR"LIQUID TIGHT FROM POINT OF EXIT FROM CONDUIT STUB OR POWER JOB NUMBER: 02GPD-170493 L 2. THE CATEGORY 5E PATCH CABLES SHALL BE FOUR(4)PAIR 24 AWG STRANDED UTP,PVC C. ALL PENETRATIONS THROUGH FIRE RATED FLOORS AND WALLS SHALL BE SEALED TO E. J-HOOK CABLE SUPPORTS SHALL HAVE AN ELECTRO-GALVANIZED OR G60 FINISH AND SHALLPOLE FITTING TO ENTRY POINT INTO RACEWAY. 5. VELCRO WRAPS SHALL BE USED AT APPROPRIATE INTERVALS TO SECURE CABLE AND IN LENGTHS OF THREE{3),FIVE(5)AND SEVEN(7)FEET AND COLOR AS FOLLOWS: BE RATED FOR INDOOR USE IN NON-CORROSIVE ENVIRONMENTS. PREVENT THE PASSAGE OF SMOKE,FIRE,TOXIC GAS OR WATER THROUGH THE PENETRATION- TO PROVIDE STRAIN RELIEF AT TERMINATION POINTS. VELCRO WRAPS SHALL BE M F. STAINLESS STEEL)-HOOK CABLE SUPPORTS ARE INTENDED FOR INDOOR AND OUTDOOR USE THE FIRE RATING OF THE PENETRATION SEAL SHALL BE AT LEAST THAT OF THE FLOOR OR 8. ALL HORIZONTAL DISTRIBUTION CABLING FEEDING DESKTOP SURFACE MOUNT OUTLETS TIGHTENED ENOUGH TO HOLD CABLE SECURELY IN PLACE WITHOUT DEFORMING OR TITLE: CL 3. CATEGORY 5E PATCH CORP THREE(3)FOOT IN NON CORROSIVE ENVIRONMENTS OR WHERE ONLY MILDLY CORROSIVE CONDITIONS APPLY. WALL INTO WHICH IT IS INSTALLED,SO THAT THE ORIGINAL FIRE RATING OF THE FLOOR OR SHALL BE ENCLOSED IN APPROPRIATELY SIZED CONVOLUTED TUBING OR MESH WRAP CRIMPING THE CABLE SHEATH IN ANY WAY. ,p ' A ORTRONICS PART NO.OR-MC5E03-08 G. J-HOOK CABLE SUPPORTS SHALL BE: WALL IS MAINTAINED AS REQUIRED BY ARTICLE 300-21 OF THE NATIONAL ELECTRIC CODE. FROM POINT OF EXIT FROM CONDUIT STUB OR FLOOR BOX FITTING TO ENTRY POINT 6. HOOK AND LOOP(VELCRO-TYPE)CABLE MANAGERS SHOULD BE USED IN SPACES •▪ . p D. FIRE STOPPING SEALANT SHALL BE POURED INTO THE HOLE AFTER EACH CABLE HAS BEEN INTO THE SURFACE MOUNT OUTLET, TELECOMMUNICATIONS Q go 4. CATEGORY 5E PATCH CORD-FIVE(5)FOOT 1. ERICO CABLECATTM J-HOOK SERIES CAT12,CAT21,CAT32,CAT64,CAT21SS,CAT32SS, SPREAD TO ALLOW A MINIMUM OF 1/i"OF FOAM TO FLOW BETWEEN THEM. NO CABLE MAY WHERE RECONFIGURATION OF CABLES AND TERMINATIONS MAY BE FREQUENT. CAT64SS;CAT-CMTM DOUBLE J-HOOK CAT100CM;CAT-CMTM U-HOOK SERIES TOUCH ANOTHER,THEREBY PREVENTING VOIDS FROM FORMING IN THE FIRE STOP. 9. AS INDICATED,CABLING SHALL RUN TO WORKSTATION AND OTHER OUTLETS THROUGH 7. PLASTIC CABLE TIES WILL NOT BE PERMITTED ON ANY PORTION OF PROJECT SPECIFICATIONS I A ORTRONICS PART NO.OR-MC5E05-08 CAT200CMLN,CAT300CMLN;AND CAT-CMTM RETAINER CATRT200CM,CATRT300CM E. IF PLASTIC CARTRIDGES ARE USED FOR SMALLER INSTALLATIONS,THE CHEMICAL CAVITIES IN THE DRYWALL AND OPENINGS IN SHEET METAL OR WOODEN STUDS WITHIN O epi 5. CATEGORY 5E PATCH CORD-SEVEN(7)FOOT H. IF REQUIRED,THE MULTI-TIER SUPPORT BRACKET MAY BE ASSEMBLED TO MANUFACTURER COMPONENTS OF THE FOAM SHALL BE PRE-MEASURED WITHIN THE CARTRIDGES TO ENSURE THE DRYWALL CONSTRUCTION. THE SHEET METAL STUDS WILL NOT BE GASKETED FOR 8. WORK DEEMED NOT TO CONFORM TO THE CABLE DRESSING AND TERMINATION [V THE PROPER RATIOS. THIS PURPOSE;IT SHALL BE THE SUBCONTRACTOR'S RESPONSIBILITY TO EXERCISE METHODS DESCRIBED WITHIN CONTRACT DOCUMENTS SHALL BE REDRESSED OR n A ORTRONICS PART NO.OR-MCSE07-08 RECOMMENDED SPECIALTY FASTENERS INCLUDING BEAM CLAMPS,FLANGE CLIPS,C AND ZSHEET NUMBER: PURLIN CLIPS. F. THE SEALANT SHALL REMAIN RESILIENT AND PLIABLE TO ALLOW FOR THE REMOVAL AND/OR EXTREME CARE IN SNAKING CABLE THROUGH THESE AREAS TO AVOID DAMAGE TO THE REMOVED AND REPLACED AS REQUIRED AT THE DIRECTION OF THE CONSTRUCTION ADDITION OF GABLE WITHOUT THE NECESSITY OF DRILLING HOLES- CABLE JACKETING. MANAGER,AT NO ADDITIONAL COST TO THE OWNER. ie 2 �] 2.06 HORIZONTAL CABLE TERMINATIONS(WORK AREA END) I. MULTI-TIERED SUPPORT BRACKET SHALL BE:= 1. ERICO CADDY CATHBA AND CABLECATTM J-HOOKS WITH SCREWS. G. NO FLAMMABLE MATERIAL MAY BE USED TO LINE THE CHASE OF A HOLE IN WHICH THE FIRE E. CABLE ROUTING AT RACKS AND CABINETS 3.14 PATCH CORDS # N A. APPROVED MANUFACTURER STOP MATERIAL IS TO BE INSTALLED. V9 O 1ALL WORK SHALL BE DONE IN A WORKMANLIKE FASHION(SEE DEFINITION OF y+/ 1. ORTRONICS;UNLESS OTHERWISE .SPECIFIED 2. TEE BAR SUPPORT BRACKET WITH ONE J-HOOK CABLE SUPPORT,FACTORY OR JOBSITE H. WHEN DAMMING MATERIALS ARE TO BE LEFT IN PLACE AFTER THE SEAL 15 COMPLETE,ALL A. SUBCONTRACTOR SHALL FURNISH PATCH CORDS IN THE QUANTITIES AS SPECIFIED 1N 2 4 2 v 0 ASSEMBLED;RATED FOR INDOOR USE IN NON-CORROSIVE ENVIRONMENTS;CULUS SUCH MATERIALS SHALL BE NON-FLAMMABLE. WORKMANLIKE IN PART I OF THIS DOCUMENT)OF THE HIGHEST STANDARDS- SECTION 2 OF THIS SPECIFICATION-INSTALLATION OF PATCH CORDS IS REQUIRED FOR B. INFORMATION OUTLETS LISTED;ERICO CADDY CAT12TS,CAT21528,CAT32528 I. FIRE STOP SHALL ADHERE TO ITSELF PERFECTLY TO ALLOW ANY AND ALL REPAIRS TO BE INSTALLATION PROCEDURE SHALL BE AS FOLLOWS: CAMERAS AND WAP'S ONLY.COORDINATE WITH SECURITY SUBCONTRACTOR FOR CAMERA 7 II 1. THE INFORMATION OUTLET WILL CONSIST OF 8-PIN MODULAR JACK TO INSULATION MADE WITH THE SAME MATERIAL. IT SHALL ALSO ALLOW FOR VIBRATION,EXPANSION AND/OR A UPON COMPLETION OF INSTALLING PANELS AND DRESSING CABLES 1N A SINGLE INSTALLATION. COMMENTS: m DISPLACEMENT CONNECTOR(IDC). THE IDC ACCEPTS 22 TO 24 AWG INSULATED WIRE. J. FASTENER TO WIRE/ROD WITH ONE J-HOOK CABLE SUPPORT,FACTORY OR JOBSITE CONTRACTION OF ANYTHING PASSING THROUGH THE PENETRATION WITHOUT AFFECTING THE B. PRIOR TO ORDERING ANY PATCH CORDS THE SUBCONTRACTOR SHALL VERIFY PATCH CABLE II II 0 THE 4-PAIR CATEGORY 6 UTP CABLES WILL BE TERMINATED ON IDC UTILIZING THE ASSEMBLED;RATED FOR INDOOR USE IN NON-CORROSIVE ENVIRONMENTS;CULUS LISTED; SEAL,OR CRACKING,CRUMBLING AND SPALLING. RACK AND SINGLE CABINET DO NOT CONTINUE INSTALLATION IN REMAINING COLORS AND QUANTITIES WITH OWNER AND ENGINEER. r0." ERICO CADDY CAT124Z34,CAT126Z34,CAT214Z34,CAT216234,CAT324Z34 OR CAT326Z34. Om ff N.. ........ ,.... .... y...,....,.�- .... .._,- . - . _ _..-_._ -- <._. .- --. __ -......, . C. CONTRACTOR SHALL PROACTIVELY COORDINATE THE PURCHASE AND DELIVERY OF PATCH IN THE PERMANENT LINK OR CHANNEL. THE TERM"ATTENUATION"HAS BEEN USED DETERMINED BY EACH OF THE FOLLOWING FORMULAS: 3 CORDS WITH THE CONSTRUCTION MANAGER,OWNER AND ENGINEER TO ASSURE TIMELY TO DESIGNATE"INSERTION LOSS."IT IS PREFERRED TO MEASURE INSERTION LOSS DELIVERY OF MATERIALS TO OWNER IN ACCORDANCE WITH PROJECT SCHEDULE AT THE SAME FREQUENCY INTERVALS AS NEXT LOSS IN ORDER TO PROVIDE A 1) CABLE ATTENUATION: REQUIREMENTS. MORE ACCURATE CALCULATION OF THE ATTENUATION-TO-CROSSTALK RATIO(ACR) • CABLE ATTN.(DB)=ATTN.COEFFICIENT(DB/KM)X LENGTH(KM) ! 3.15 GROUNDING PARAMETER. 1 A. COMMUNICATION GROUNDING/EARTHING AND BONDING SHALL BE IN ACCORDANCE WITH D NEXT-PAIR-TO-PAIR NEAR-END CROSSTALK LOSS(ABBREVIATED AS NEXT)SHALL 2) ATTENUATION COEFFICIENT: 8 APPLICABLE CODES AND REGULATIONS- BE TESTED FOR EACH WIRE PAIR COMBINATION FROM EACH END OF THE LINK(A TOTAL OF 12 PAIR COMBINATIONS).NEXT LOSS MEASURES THE CROSSTALK • =1.0 DB/KM @ 1310 NM FOR SINGLE-MODE INSIDE PLANT '' B. ALL METAL PRODUCTS INSTALLED BY THIS SUBCONTRACTOR SHALL BE GROUNDED TO THE DISTURBANCE ON A WIRE PAIR AT THE END FROM WHICH THE DISTURBANCE a EXISTING TELECOMMUNICATIONS GROUNDING SYSTEM LOCATED BENEATH THE RASED SIGNAL IS TRANSMITTED(NEAR-END)ON THE DISTURBING PAIR. • =.5 DB/KM©1550 NM FOR SINGLE-MODE INSIDE PLANT ACCESS FLOOR. E PSNEXT-POWER SUM NEXT SHALL BE EVALUATED AND REPORTED FOR EACH WIRE ! Health 3.16 LADDER RACKPAIR FROM BOTH ENDS OF THE LINK-UNDER-TEST(A TOTAL OF 8 RESULTS).PSNEXT i CONNECTOR ATTENUATION: A. INSTALLATION AND CONFIGURATION SHALL CONFORM TO THE REQUIREMENTS OF THE ANSI! LOSS CAPTURES THE COMBINED NEAR-END CROSSTALK EFFECT(STATISTICAL)ON 1) CONNECTOR ATTN.(DB)=NUMBER OF CONNECTOR PAIRS X CONNECTOR LOSS EIA/TIA STANDARDS 568&569,NFPA 70(NATIONAL ELECTRICAL CODE),AND APPLICABLE LOCAL A WIRE PAIR WHEN ALL OTHER PAIRS ACTIVELY TRANSMIT SIGNALS. CODES. F ELFEXT-PAIR-TO-PAIR FEXT LOSS SHALL BE MEASURED FOR EACH WIRE-PAIR • =2 X 0.50 DB c B. SUBCONTRACTOR IS RESPONSIBLE FOR USING ALL THE PROPER FITTINGS AND ACCESSORIES COMBINATION FROM BOTH ENDS OF THE LINK-UNDER-TEST.FEXT LOSS MEASURES THE CROSSTALK DISTURBANCE ON A WIRE PAIR AT THE OPPOSITE END(FAR-END) • =1.0 DB TO PROPERLY INSTALL THE LADDER RACK SYSTEM, FROM WHICH THE TRANSMITTER EMITS THE DISTURBING SIGNAL ON THE C. RUNWAY SHALL BE SUPPORTED AT EVERY 4 FEET ON CENTER WITH 3/8 INCH DIAMETER DISTURBING PAIR..ELFEXT MEASURES THE RELATIVE STRENGTH OF THE FAR-END F SPLICE ATTENUATION THREADED ROD AT EACH STRINGER(TRAPEZE STYLE). CENTER HUNG SUPPORTS SHALL NOT CROSSTALK DISTURBANCE RELATIVE TO THE ATTENUATED SIGNAL THAT ARRIVES BE ACCEPTABLE. AT THE END OF THE LINK.THIS TEST YIELDS 24 WIRE PAIR COMBINATIONS 1) SPLICE ATTN.(DB)=NUMBER OF SPLICES(S)X SPLICE LOSS(DB) D. THREADED ROD SHALL BE EQUIPPED WITH THREADED ROD COVER WHEREVER IT ATTACHES • G PSELFEXT-POWER SUM ELFEXT ISA CALCULATED PARAMETER THAT COMBINES • =#OF SPLICES X 0-3 DB TO THE LADDER RACK THE EFFECT OF THE FEXT DISTURBANCE FROM THREE WIRE PAIRS ON THE FOURTH CORAM, INC. E. LADDER RACK SHALL BE SUPPORTED AT EACH END AT WALL UTILIZING WALL ANGLE SUPPORT ONE.THIS TEST YIELDS 8 WIRE-PAIR COMBINATIONS. I. THE SUBCONTRACTOR SHALL PROVIDE COPIES OF ALL FIBER CABLE TEST RESULTS TO THE 7358 S W DURHAM RD. KITS. TRIANGLE SUPPORT BRACKETS SHALL NOT BE ACCEPTABLE. H RETURN LOSS-RETURN LOSS(RL)MEASURES THE TOTAL ENERGY REFLECTED ON CONSTRUCTION MANAGER. �7 F. RUNWAY SHALL BE EQUIPPED WITH LADDER RACK UNIVERSAL DROPOUTS ACCURATELY EACH WIRE PAIR.RETURN LOSS IS TO BE MEASURED FROM BOTH ENDS OF THE 3.22 CABLE REPLACEMENT PORTLAND LANDOR 97224 ALIGNED WITH THE EQUIPMENT RACK VERTICAL CABLE CHANNELS. THE UNIVERSAL LINK-UNDER-TEST FOR EACH WIRE PAIR. , DROPOUTS CABLEOSHOULD PROVIDE A COMPLETE UNOBSTRUCTED PATHWAY FOR CABLING INTO THE I ACR(ATTENUATION TO CROSSTALK RATIO)[THIS PARAMETER IS NOT DEMANDED BY A- ANY FIBER STRAND,CONNECTOR,BLOCK,OR MODULE INSTALLED BY THE SUBCONTRACTOR, PROJECT TYPE P„� ., VERTICALTHE STANDARD BUT MAY BE REQUIRED IN ORDER TO OBTAIN THE PREMISE WIRING WHICH FAILS TO MEET THE LOSS BUDGET OR TESTS BELOW THE MANUFACTURER'S fl MIGV TYPE: 3.17 CORE DRILLING-BY ELECTRICAL CONTRACTOR MANUFACTURER'S WARRANTY]ACR PROVIDES AN INDICATION OF BANDWIDTH FOR STANDARDS,SHALL BE REPLACED AT NO ADDITIONAL COST TO CLIENT. DEAL TYPE: Mil A. CORE DRILLING AND THE INSTALLATION OF CONDUITS,FIRE RATED POKE-THROUGH FITTINGS, THE TWO W1RE-PAIR NETWORK APPLICATIONS.ACR ISA COMPUTED PARAMETER B. THE REPLACEMENT CABLE,CONNECTOR,OR PART SHALL BE TESTED AFTER REPAIRS HAVE AND RACEWAYS REQUIRED TO ROUTE COPPER AND FIBER OPTIC CABLING WILL BE FURNISHED THAT IS ANALOGOUS TO ELFEXT AND EXPRESSES THE SIGNAL TO NOISE RATIO FOR BEEN MADE TO VERIFY COMPLIANCE.ONLY EQUIPMENT THAT MEETS THE INSTALLATION �1�L �f AND INSTALLED BY PARTIES AS INDICATED BY CONTRACT DOCUMENTS. A TWO WIRE-PAIR SYSTEM.THIS CALCULATION YIELDS 12 COMBINATIONS-SIX REQUIREMENTS STATED HEREIN SHALL MEET CLIENTS ACCEPTANCE REQUIREMENTS. W PROJECT NUMBER 0106369v 3.18 LABELING FROM EACH END OF THE LINK. 3.23 CABLE TESTING ACCEPTANCE J PSACR[THIS PARAMETER IS NOT REQUIRED BY THE STANDARD BUT MAY BE A. CABLES REQUIRED IN ORDER TO OBTAIN THE PREMISE WIRING VENDOR'S WARRANTY]. THE A. CLIENT MAY RESERVE THE RIGHT TO OBSERVE ANY OR ALL PORTIONS OF THE TESTING. POWER SUM VERSION OF ACR IS BASED ON PSNEXT AND TAKES INTO ACCOUNT NOTIFICATION OF TESTING SHALL BE THREE(3)DAYS PRIOR TO START OF TESTING. 1 HORIZONTAL AND BACKBONE CABLES SHALL BE LABELED AT EACH END WITHIN 6-INCHES OF THE END OF THE CABLE. THE CABLE OR ITS LABEL SHALL BE MARKED WITH THE COMBINED NEXT DISTURBANCE OF ALL ADJACENT WIRE PAIRS ON EACH B. UPON RECEIPT OF THE SUBCONTRACTOR'S CABLE TESTING DOCUMENTATION,CLIENT MAY • '�RCHf f ECT OF RECORD ITS IDENTIFIER. INDIVIDUAL PAIR.THIS CALCULATION YIELDS 8 COMBINATIONS-ONE FOR EACH REVIEW AND INSPECT THE INSTALLATION AND REQUEST RANDOM TESTS OF THE CABLES WIRE PAIR FROM BOTH ENDS OF THE LINK. INSTALLED. THE NUMBER OF CABLES SO RANDOMLY TESTED SHALL NOT EXCEED 5%OF THE 2- BACKBONE CABLES SHALL ADDITIONALLY BE LABELED AT 5-FOOT AFF ON EACH FLOOR K PROPAGATION DELAY-PROPAGATION DELAY IS THE TIME REQUIRED FOR THE TOTAL NUMBER OF CABLES INSTALLED. ONCE THE TESTING HAS BEEN COMPLETED AND LEVEL THE CABLE PASSES THROUGH WITHOUT TERMINATING. SIGNAL TO TRAVEL FROM ONE OF THE LINK TO THE OTHER.THIS MEASUREMENT IS CLIENT IS SATISFIED THAT ALL WORK IS IN ACCORDANCE WITH THE CONTRACT DOCUMENTS 3- SUBSEQUENT TO PULLING AND TERMINATING CABLES,THE SUBCONTRACTOR SHALL TO BE PERFORMED FOR EACH OF THE FOUR WIRE PAIRS. AND REQUIREMENTS,CLIENT WILL NOTIFY THE CONSTRUCTION MANAGER IN WRITING- PLACE THE APPROPRIATE CABLE LABELS SIX(6)INCHES FROM EACH END OF EACH L DELAY SKEW-THIS PARAMETER SHOWS THE DIFFERENCE IN PROPAGATION DELAY C. SUBCONTRACTOR SHALL PROVIDE ALTERNATE PRICING FOR RANDOM CABLE TESTING IN ITS BETWEEN THE FOUR WIRE PAIRS.THE PAIR WITH THE SHORTEST PROPAGATION PROPOSAL,BASED UPON 5%OF THE TOTAL NUMBER OF CABLES INSTALLED. COPPER CABLE AND SIX(6)INCHES FROM EACH OPTICAL FIBER CABLE END. DELAY IS THE REFERENCE PAIR WITH A DELAY SKEW VALUE OF ZERO. D. CLIENT MAY CONDUCT PERFORMANCE TESTS OF TRANSPORT ELECTRONICS CONNECTED TO 4. IF AT ANY TIME DURING THE JOB,THE CABLE LABEL BECOMES ILLEGIBLE OR REMOVED, M ALL INSTALLED CATEGORY 6 PERMANENT LINKS"SHALL PERFORM EQUAL TO OR BETTER THAN THE MINIMUM REQUIREMENTS AS SPECIFIED BY THE TABLE BELOW: THE CABLING SYSTEM. SUCCESSFUL EQUIPMENT PERFORMANCE TESTS DO NOT RELIEVE THE THE SUBCONTRACTOR SHALL IMMEDIATELY REPLACE IT WITH A DUPLICATE PREPRINTED SUBCONTRACTOR FROM THE SPECIFIED TESTING,REPAIR,AND DOCUMENTATION CABLE TAG. REQUIREMENTS. 5. THE SUBCONTRACTOR SHALL PROVIDE A LISTING KEYED TO CABLE TYPES OF ALL CABLE WORST CASE PERMANENT LINK PERFORMANCE AT SPECIFIED FREQUENCY 3.24 TEST DOCUMENTS IDENTIFICATION NUMBERS. (DB)PARAMETER100MHZ200MHZ25OMHZ ATTENUATION(INSERTION LOSS)18.627.431.1NEXT A. UPON COMPLETION OF TESTING,THE CONTRACTOR SHALL SUBMIT TO THE CONSTRUCTION LOSS41.836.935.3POWER SUM NEXT LOSS39.334.332.7ELFEXT24-218-216-2POWER SUM MANAGER FOUR(4)FULL SETS OF TEST RESULTS. B. FACEPLATES ELFEXT21.215.213.2RETURN LOSS14.011-010.OACR23.39.64.2POWER SUMACR20.77-01-BF. 1. THE SUBCONTRACTOR SHALL LABEL EACH INFORMATION OUTLET AS DIRECTED. SEE TEST RESULTS DOCUMENTATION B. CABLE RECORDS MUST CONTAIN THE IDENTIFIER,CABLE TYPE,AND TERMINATION POSITIONS DRAWINGS FOR LABELING DETAIL AT BOTH-ENDS,SPLICE INFORMATION AS WELL AS ANY DAMAGED PAIRS/CONDUCTORS, 2. THE SUBCONTRACTOR SHALL AFFIX OUTLET IDENTIFICATION LABELS,MACHINE PRINTED 1. THE TEST RESULTS INFORMATION FOR EACH LINK SHALL BE RECORDED IN THE MEMORY C. CONNECTING HARDWARE AND CONNECTING HARDWARE POSITION RECORDS MUST CONTAIN OF THE FIELD TESTER UPON COMPLETION OF THE TEST. THE IDENTIFIER,TYPE,DAMAGED POSITION NUMBERS,AND REFERENCES TO THE CABLE WITH IDENTIFYING CABLE NUMBERS AS SHOWN ON THE ASSOCIATED DRAWINGS. IDENTIFIER ATTACHED TO IT. =` 3. A UNIQUE IDENTIFIER SHALL BE MARKED ON EACH FACEPLATE TO IDENTIFY IT AS 2. THE TEST RESULTS RECORDS SAVED BY THE TESTER SHALL BE TRANSFERRED INTO A D. TEST DOCUMENTATION SHALL BE SUBMITTED IN ELECTRONIC FORM ON A CD-ROM,WITH THE WINDOWSTM-BASED DATABASE UTILITY THAT ALLOWS FOR THE MAINTENANCE, APPROPRIATE SOFTWARE REQUIRED TO READ ALL TEST DATA. - • ' - CONNECTING HARDWARE. CONSULTANT:INSPECTION AND ARCHIVING OF THESE TEST RECORDS.A GUARANTEE MUST BE MADE 3.25 WARRANTY DATA C. RACKS,PANELS,BLOCKS THAT THE MEASUREMENT RESULTS ARE TRANSFERRED TO THE PC UNALTERED AT THE 1. THE SUBCONTRACTOR SHALL PROVIDE AND INSTALL LABELS,MACHINE PRINTED OR END OF EACH TEST AND THAT THESE RESULTS CANNOT BE MODIFIED AT A LATER TIME. A. ALL BIDDERS MUST CURRENTLY BE EXTENDED WARRANTY CERTIFIED IN THE PRODUCT LINES TYPED,WITH IDENTIFYING PATCH PANEL NUMBERS AS SHOWN ON THE ASSOCIATED SPECIFIED IN THIS DOCUMENT A COPY OF SUCH CERTIFICATION IS TO BE PROVIDED AS AN DRAWINGS. 3. THE DATABASE FOR THE COMPLETED JOB SHALL BE STORED AND DELIVERED ON ATTACHMENT TO THE BID RESPONSE- . CD-ROM INCLUDING THE SOFTWARE TOOLS REQUIRED TO VIEW,INSPECT,AND PRINT B. THE BID PACKAGE SHALL BE ACCOMPANIED BY A PRESALE WARRANTY COMMITMENT BINDING 2. SEE DRAWINGS FOR LABELING DETAILS. ANY SELECTION OF TEST REPORTS, THE SUBCONTRACTOR AND MANUFACTURER TO THE CUSTOMER,AN EXTENDED NETCLEAR n �}pn r 3.19 PHYSICAL INSPECTION WARRANTY PACKAGE NOT LESS THAN 25 YEARS IN LENGTH, EI Ig I I I V V 1 S� 4. TEST RESULTS SHALL PROVIDE THE FOLLOWING SUMMARY INFORMATION: C. THE CABLING SYSTEM MANUFACTURER SHALL ACT AS THE SOLE POINT OF CONTACT FOR A. PRIOR TO CONDUCTING ANY TRANSMISSION TESTING,THE FOLLOWING VISUAL INSPECTIONS SHALL BE PERFORMED: A THE IDENTIFICATION OF THE LINK IN ACCORDANCE WITH THE NAMING CONVENTION RESOLUTION OF ANY WARRANTY ISSUES DURING THE ENTIRE TERM OF THE WARRANTY. Consultants 1. VERIFY THAT ALL CABLE HAS BEEN INSTALLED TO FULL COMPLIANCE WITH THE DEFINED IN THE OVERALL SYSTEM DOCUMENTATION D. PRIOR TO COMMENCEMENT OF THE WORK,THE SUCCESSFUL BIDDER SHALL PROVIDE EVIDENCE THAT THIS PROJECT IS REGISTERED WITH THE MANUFACTURER UNDER THE PROPOSAL SPECIFICATIONS. B THE OVERALL PASS/FAIL EVALUATION OF THE LINK-UNDER-TEST INCLUDING THE WARRANTY PROGRAM. - MO 2. CHECK FOR PHYSICAL DAMAGE TO THE FIBER DISTRIBUTION PANELS AND COPPER NEXT HEADROOM(OVERALL WORST CASE)NUMBER E. UPON COMPLETION OF THE WORK,THE SUBCONTRACTOR SHALL COORDINATE WITH THE TERMINATION HARDWARE. C THE DATE AND TIME THE TEST RESULTS WERE SAVED IN THE MEMORY OF THE MANUFACTURER,THE ISSUANCE OF A FULL WARRANTY ON THE ENTIRE COPPER AND FIBER 155 SEAPORT BOULEVARD TESTER OPTIC CABLE PLANT FOR BOTH PARTS AND LABOR. SEAPORT WEST, FLOOR 2 • 3. CHECK THAT ALL CABLING IS PROPERLY JACKETED,PROPERLY LABELED AT BOTH ENDS D THE IDENTIFICATION OF THE CUSTOMER SITE AS SPECIFIED BY THE END-USER F. EXISTING AND FUTURE APPLICATIONS SUPPORTED FOR A CHANNEL MODEL WARRANTY BOSTON, MA 02210 OF THE CABLE,AND TERMINATION HARDWARE IS COMPLETED- E THE NAME OF THE STANDARD SELECTED TO EXECUTE THE STORED TEST RESULTS INCLUDE THOSE APPROVED BY THE INSTITUTE OF ELECTRONIC AND ELECTRICAL ENGINEERS P. 617.443.4950 • F. 617.443.4959 4. VERIFY THAT ALL CABLE BENDS ARE WITHIN THE MANUFACTURER'S SPECIFIED BEND F THE BRAND NAME,MODEL AND SERIAL NUMBER OF THE TESTER (IEEE),THE ASYNCHRONOUS TRANSFER MODE(ATM)FORUM,THE AMERICAN NATIONAL RADIUS. STANDARDS INSTITUTE(ANSI)OR THE INTERNATIONAL ORGANIZATION OF STANDARDS(ISO) G THE IDENTIFICATION OF THE TESTER INTERFACE THAT SPECIFY COMPATIBILITY WITH THE CABLING INSTALLED HEREUNDER. ADDITIONAL 5. VERIFY THAT ALL CABINETS AND RACKS(WHICH REQUIRE GROUNDING)ARE PROPERLY H THE REVISION OF THE TESTER SOFTWARE AND THE REVISION OF THE TEST APPLICATIONS THAT ARE COVERED BY THIS WARRANTY INCLUDE THOSE UNDER GROUNDED AND COMPLY WITH NATIONAL AND LOCAL ELECTRICAL CODES AND STANDARDS DATABASE IN THE TESTER DEVELOPMENT FOR USE ON GIGABIT ETHERNET(IEEE 802-3Z,802.3AB)AND 622 MB/S ATM. DEVELOPER. ANSI/TIA/EIA-607 STANDARDS FOR TELECOMMUNICATIONS BONDING AND GROUNDING. 5. THE TEST RESULTS INFORMATION MUST CONTAIN INFORMATION ON EACH OF THE G. THE CABLING SUBCONTRACTOR AT HIS SOLE EXPENSE WILL CORRECT ANY DEFICIENCIES DID • 6. VERIFY THAT THE CABLES ARE PROPERLY APPROVED AND STRUCTURALLY SUPPORTED REQUIRED TEST PARAMETERS THAT ARE LISTED IN SECTION 3.03 F IN ONE OF THE DETERMINED BY THE MANUFACTURER. FOR TERMINATION. FOLLOWING TWO(2)FORMATS: H. CLIENT WILL HOLD TEN(10)PERCENT RETAINAGE ON THE FULL DOLLAR AMOUNT OF THE CONTRACT UNTIL THE EXTENDED WARRANTY CERTIFICATE IS RECEIVED. 7. VERIFY THAT THE REQUIREMENTS OF ALL AUTHORITIES HAVING JURISDICTION HAVE A FOR EACH OF THE FREQUENCY-DEPENDENT TEST PARAMETERS.THE VALUE I. APPLICATIONS ASSURANCE IS APPLIED TO THE CHANNEL MODEL CONFIGURATION OF THIS BEEN SATISFIED. MEASURED AT EVERY FREQUENCY DURING THE TEST IS STORED.IN THIS CASE,THE INSTALLATION. 8. CONDUCT AN ACCEPTANCE WALK-THROUGH WITH WB ENGINEERS I CONSULTANTS FIELD PC-RESIDENT DATABASE PROGRAM MUST BE ABLE TO PROCESS THE STORED J. THE MANUFACTURER OF PASSIVE TELECOMMUNICATIONS EQUIPMENT USED IN A MANNER NOT RESULTS TO DISPLAY AND PRINT A COLOR GRAPH OF THE MEASURED ASSOCIATED WITH THE SYSTEMS WARRANTY MUST HAVE A MINIMUM FIVE-YEAR COMPONENT ENGINEER,OWNER,GENERAL CONTRACTOR AND CONSTRUCTION MANAGER. PARAMETERS.THE PC-RESIDENT SOFTWARE MUST ALSO PROVIDE A SUMMARY WARRANTY ON ITS ENTIRE PRODUCT. THE PRODUCTS WARRANTY COVERS THE COMPONENTS PROACTIVELY COORDINATE DATE AND TIME TO ALLOW TWO DAY NOTICE AND ASSURE NUMERIC FORMAT IN WHICH SOME CRITICAL INFORMATION IS PROVIDED AGAINST DEFECTS IN MATERIAL OR WORKMANSHIP UNDER NORMAL AND PROPER USE. COMPLIANCE WITH ALL PROJECT SCHEDULES. NUMERICALLY AS DEFINED BY THE SUMMARY RESULTS. K. THE EXTENDED WARRANTY IS TO BE PROVIDED TO CLIENT IMMEDIATELY UPON COMPLETION 3.20 COPPER TESTING PROCEDURES OF THE TESTING AND MANUFACTURER'S CERTIFICATION. B FOR EACH OF THE FREQUENCY-DEPENDENT TEST PARAMETERS,THE MINIMUM A. SUBCONTRACTOR SHALL COMPLETE CABLE SYSTEM PERFORMANCE VERIFICATIONS ON ALL TEST RESULTS DOCUMENTATION SHALL BE STORED FOR EACH WIRE-PAIR OR COPPER CABLE AS SPECIFIED BELOW AND PROVIDE THE TEST RESULTS TO THE WIRE-PAIR COMBINATION AS OBSERVED FROM EACH END OF THE LINK.LINK CONSTRUCTION MANAGER. CATEGORY 5E,CATEGORY 6,AND CATEGORY 6A CABLE(S)SHALL LENGTH,PROPAGATION DELAY,AND DELAY SKEW SHALL BE REPORTED FOR EACH ... . MEET OR EXCEED ALL MANUFACTURER'S AND EIA/TIA STANDARDS FOR PERFORMANCE AND WIRE PAIR AS WELL AS THE TEST LIMIT FOR EACH OF THESE PARAMETERS. INSTALLATION. B. ALL CABLE TEST RESULTS AND CORRECTIVE PROCEDURES ARE TO BE DOCUMENTED AND 3.21 FIBER TESTING PROCEDURES SEAL•• SUBMITTED TO THE CONSTRUCTION MANAGER WITHIN THREE(3)BUSINESS DAYS OF TEST COMPLETION. A. ALL FIBER OPTIC CABLING SHALL BE THOROUGHLY TESTED,CLIENT WILL ACCEPT THE FIBER C. THE SUBCONTRACTOR SHALL,AT A MINIMUM,CONDUCT AND REPORT ON THE FOLLOWING CABLE ONLY AFTER EACH STRAND IS TESTED IN ACCORDANCE WITH THE SPECIFICATIONS TESTS OF COPPER CABLING: DEFINED HEREIN.CLIENT REQUIRES THAT ALL STRANDS ARE TESTED AND FOUND TO BE 100% 1. TESTS OF ALL CATEGORY 3 AND CATEGORY 5E BACKBONE PAIRS TO DETERMINE ACCEPTABLE. CONTINUITY,SHORTS,CROSSED PAIRS,CORRECT PINNING,GROUNDS,AND OPENS B. SOURCE MANUFACTURING AND QUALITY CONTROL 2. TESTS OF ALL CATEGORY 6 4-PAIR CABLES FOR COMPLIANCE WITH EIAITIA CATEGORY 6 1. THE SUBCONTRACTOR SHALL TEST ALL CABLES,CONNECTORS,ASSOCIATED REQUIREMENTS. EQUIPMENT AND HARDWARE FURNISHED BY THE SUBCONTRACTOR UPON RECEIPT OF SAME AS DEFINED HEREIN. D. TESTS OF ALL CATEGORY 6 AND CATEGORY 6A 4-PAIR CABLES FOR COMPLIANCE WITH EIA/TIA CATEGORY 6 REQUIREMENTS. ALIEN CROSSTALK IS NOT REQUIRED FOR CATEGORY BA. TEST 2. CABLES THAT ARE SUPPLIED BY THE SUBCONTRACTOR,AND TEST OUTSIDE OF THE CATEGORY 6A TO CATEGORY 6 REQUIREMENTS IN ACCORDANCE WITH MANUFACTURERS FACTORY TEST DATA BY A MARGIN OF 10 PERCENT ON LOSS,MAY,AT CLIENT'S OPTION, GUIDELINES AND THIS DOCUMENT. BE DEEMED NON-USABLE AND RETURNED TO THE MANUFACTURER FOR REPLACEMENT E. CATEGORY 6 TESTING GENERAL REQUIREMENTS: AT NO ADDITIONAL COST TO CLIENT. 1. EVERY CABLING LINK IN THE INSTALLATION SHALL BE TESTED IN ACCORDANCE WITH C. AS A MINIMUM,THE SUBCONTRACTOR SHALL TEST,AS DESCRIBED BELOW,ALL OPTICAL FIBER THE FIELD TEST SPECIFICATIONS DEFINED IN THE"TRANSMISSION PERFORMANCE CABLE STRANDS INSTALLED UNDER THIS CONTRACT.THE FOLLOWING SHALL BE MET FOR THE SPECIFICATIONS FOR 4-PAIR 100 0 CATEGORY 6 CABLING°BY THE TESTING OF THE FIBER OPTIC CABLE: TELECOMMUNICATIONS INDUSTRY ASSOCIATION(TIA);ANSVTIAIEIA-568-B-2-1- 1. FULLY TEST COMPLETE LINKS ONLY. PIECEMEAL TESTING IS NOT ACCEPTABLE. - 1 HEREAFTER REFERRED TO AS THE"TIA CAT 6 STANDARD." � 2- THE INSTALLED TWISTED-PAIR HORIZONTAL LINKS SHALL BE TESTED FROM AGAINST 2. PERFORM END-TO-END,El-DIRECTIONAL ATTENUATION(LOSS)TEST FOR EACH FIBER REVISIONS. THE"PERMANENT LINK"PERFORMANCE LIMITS SPECIFICATION AS DEFINED IN THE TIA STRAND AT 1310NM AND 1550 NM WAVELENGTHS. CAT 6 STANDARD. 3. DEMONSTRATE THAT MEASURED LINK LOSS DOES NOT EXCEED THE EXPECTED VALUE ISSUED FOR BID-PERMIT 06.06.1 7 3- ONE HUNDRED PERCENT(100%)OF THE INSTALLED CABLING LINKS MUST BE TESTED BASED ON THE NUMBER OF MATED CONNECTOR PAIRS,THE CONNECTOR'S PUBLISHED AND MUST PASS THE REQUIREMENTS OF THE TIA CAT 6 STANDARD AND AS FURTHER LOSS PER MATED PAIR AND THE CABLE'S PUBLISHED LOSS BASED ON DISTANCE. 0+ile .i DETAILED IN THIS SPECIFICATION. ANY FAILING LINK MUST BE DIAGNOSED AND 4. STRANDS WHOSE MEASURED ATTENUATION FALLS OUTSIDE THE ACCEPTABLE RANGE erj s CORRECTED.THE CORRECTIVE ACTION SHALL BE FOLLOWED WITH A NEW TEST TO SHALL BE SUBJECT TO FURTHER INSPECTION AND TESTING TO DETERMINE THE NATURE PROVE THAT THE CORRECTED LINK MEETS THE PERFORMANCE REQUIREMENTS.THE FINAL AND PASSING RESULT OF THE TESTS FOR ALL LINKS SHALL BE PROVIDED IN THE OF THE FAULT TEST RESULTS DOCUMENTATION IN ACCORDANCE WITH THIS SPECIFICATION. D. FAULTS RELATED TO TERMINATION AND/OR SPLICING SHALL BE CORRECTED AND THE FIBER p RE-TESTED AS STATED ABOVE UNTIL ACCEPTABLE ATTENUATION MEASUREMENTS ARE 4. TRAINED TECHNICIANS,WHO HAVE SUCCESSFULLY ATTENDED AN APPROPRIATE RECEIVED. TRAINING PROGRAM AND HAVE OBTAINED A CERTIFICATE AS PROOF THEREOF,SHALL 0 EXECUTE THE TESTS.APPROPRIATE TRAINING PROGRAMS INCLUDE BUT ARE NOT E. WHERE DEFECTS ARE FOUND TO BE INHERENT IN THE FIBER ITSELF,NOTIFY THE CONSTRUCTION MANAGER IN WRITING. UPON OBTAINING APPROVAL BY THE CONSTRUCTION C LIMITED TO INSTALLATION CERTIFICATION PROGRAMS PROVIDED BY BICSI AND/OR THE MANAGER,REPLACE ANY CABLE HAVING LESS THAN THE MANUFACTURERS GUARANTEED ACP(ASSOCIATION OF CABLING PROFESSIONALS). NUMBER OF SERVICEABLE FIBERS. I 5. THE TEST EQUIPMENT(TESTER)SHALL COMPLY WITH THE ACCURACY REQUIREMENTS F. REMOVE ALL NEWLY INSTALLED DEFECTIVE CABLES FROM PATHWAYS. DO NOT ABANDON FOR THE PROPOSED LEVEL III FIELD TESTERS AS DEFINED IN THE TIA CAT 6 DOCUMENT. CABLES IN PLACE. Z THE TESTER INCLUDING THE APPROPRIATE INTERFACE ADAPTER MUST MEET THE G. ALL TEST RESULTS AND CORRECTIVE PROCEDURES ARE TO BE DOCUMENTED AND SUBMITTED SPECIFIED ACCURACY REQUIREMENTS.THE ACCURACY REQUIREMENTS FOR THE AS A SPREADSHEET TO CLIENT WITHIN THREE(3)WORKING DAYS OF TEST COMPLETION. 6 1 PERMANENT LINK TEST CONFIGURATION(BASELINE ACCURACY PLUS ADAPTER H. THE FIBER CABLE PLANT SHALL BE MANUFACTURER CERTIFIED,AT MINIMUM,EACH TEST CONTRIBUTION)ARE SPECIFIED IN TABLE B.2 OF ANNEX B OF THE TIA CAT 6 STANDARD. REPORT FORM SHALL PROVIDE FOR THE FOLLOWING INFORMATION: C '; 1. PROJECT NAME a6. THE TESTER SHALL BE WITHIN THE CALIBRATION PERIOD RECOMMENDED BY THE .„ - .. ... • -' "' ° .. VENDOR IN ORDER TO ACHIEVE THE VENDOR-SPECIFIED MEASUREMENT ACCURACY- 2. SUBCONTRACTOR'S NAME DRAWING BY: E - 7. A REPRESENTATIVE OF THE OWNER MAY SELECT A RANDOM SAMPLE OF 5%OF THE 3. DATE(S)OF PREPARATION AND OF TESTING LINKS LED R.THE REPRESENTATIVETOBE SHALL TEST THESENE WITH LE SELECTED 4_ FIBER TYPE,STRAND COUNT,CONNECTORS AND PATCHES DATE: June 06, 2017 LINKS AND THE RESULTS ARE TO BE STORED IN ACCORDANCE WITH THE PRESCRIPTIONS IN THIS SPECIFICATION. THE RESULTS OBTAINED SHALL BE COMPARED . < ...E. TO THE DATA PROVIDED BY THE INSTALLATION CONTRACTOR.IF MORE THAN 2%OF THE 5. DESIGNATED CABLE NUMBER(REGARDLESS OF WHETHER ONLY ONE CABLE OF EACH TYPE IS PRESENT)AND INDIVIDUAL FIBER NUMBERS - JOB NUMBER: 02GPD-170493 SAMPLE RESULTS DIFFER IN TERMS OF THE PASS/FAIL DETERMINATION,THE INSTALLATION CONTRACTOR UNDER SUPERVISION OF THE END-USER REPRESENTATIVE 6. MAKE,MODEL,SERIAL NUMBER AND DATE OF LAST CALIBRATION OF TEST EQUIPMENT SHALL REPEAT 100%TESTING AND THE COST SHALL BE BORNE BY THE INSTALLATION USEDTITLE: m Al 0- CONTRACTOR. 7. NAME OF TEST CREW FOREMAN TELECOMMUNICATIONS •• c:, 8. CATEGORY 6 PERFORMANCE TEST PARAMETERS-THE TEST PARAMETERS FOR CAT 6 O Fs ARE DEFINED IN TIA CAT 6 STANDARD,WHICH REFERS TO THE ANSI/TIA/EIA-568-B.2-1 8. TEST RESULTS: CALCULATED MAXIMUM LINK LOSS,LENGTH OF RUN,OTDR AND ALSO c3 STANDARD.THE TEST OF EACH LINK SHALL CONTAIN ALL OF THE FOLLOWING POWER METER MEASURED LINK LOSS FOR EACH FIBER,PASS!FAIL RESULT AND SPECIFICATIONS PARAMETERS AS DETAILED BELOW.IN ORDER TO PASS THE TEST ALL MEASUREMENTS COMMENTS. r M 0 co (AT EACH FREQUENCY IN THE RANGE FROM 1 MHZ THROUGH 250 MHZ)MUST MEET OR 9, FIBER POWER METER AND LIGHT SOURCE TESTING LreN EXCEED THE LIMIT VALUE DETERMINED IN THE STANDARD: SHEET N UMBER: A WIRE MAP-WIRE MAP SHALL REPORT PASS IF THE WRING OF EACH WIRE-PAIR A FIBER CABLES SHALL BE 100%TESTED FOR ATTENUATION AND LENGTH. cc EN FROM END TO END IS DETERMINED TO BE CORRECT-THE WIRE MAP RESULTS B ATTENUATION SHALL BE TESTED BI-DIRECTIONALLY AT 1310 NM AND 1550 NM FOR SHALL INCLUDE THE CONTINUITY OF THE SHIELD CONNECTION IF PRESENT. SINGLE-MODE FIBER. L 01 a B LENGTH-THE PHYSICAL LENGTH OF THE LINK SHALL BE CALCULATED USING THE C ACCEPTABLE ATTENUATION TEST RESULTS SHALL BE DETERMINED USING THE 7 , 3 3 T PAIR WITH THE SHORTEST ELECTRICAL DELAY.THIS FIGURE SHALL BE REPORTED FOLLOWING CALCULATIONS: Ils AND SHALL BE USED FOR MAKING THE PASS/FAIL DECISION.THE PASS/FAIL 1) LINK ATTENUATION=CABLE ATTENUATION+CONNECTOR ATTENUATION+ I- II CRITERIA ARE BASED ON THE MAXIMUM LENGTH ALLOWED FOR THE PERMANENT SPLICE ATTENUATION COMMENTS: LINK CONFIGURATION(90 METERS-295 FEET) II m C INSERTION LOSS(ATTENUATION)-INSERTION LOSS IS A MEASURE OF SIGNAL LOSS D CABLE ATTENUATION,CONNECTOR ATTENUATION AND SPLICE ATTENUATION ARE . 1 1 , AP CVS Health , r . . ___ STORE NUMBER: • CORAM, INC. 7358 S W DURHAM RD. PORTLAND, OR 97224 PROJECT TYPE PHARMACY DEAL TYPE *R CS PRWECT NUMBER: 0106369 P SAM ARCHITECT OF RECORD N D -- N / ' .; H .I A ,, i CONSULTANT _,. ,.. ..,.� .. ..� 1 N1 ^nc ineers+ 1 / : : lAB Consultants i 155 SEAPORT BOULEVARD SEAPORT WEST, FLOOR 2 BOSTON, MA 02210 P. 617.443.4950• F. 617.443.4959 DEVELOPER. SEAL: ! I 1 REVISIONS: ISSUED FOR BID-PERMIT 06.06.17 x ,, t N. 0 R W C a 1 DRAWING BY: DATE: June 06, 2017 5 JOB NUMBER: 02GPD-170493 (13 m as TITLE: •• cm TELECOMMUNICATIONS O0. ' CONSTRUCTION PLAN NSHEET NUMBER: Di Vl -O T _ \.3 <, -] co i COMMENTS: II u 6 co0 =O i \ / -I r MODULAR MODULAR ` r 1 CLOSET FURNITURE CLOSET CLOSET FURNITURE CLOSET O O 1 illp CVS LABEL WIRING LABEL LABEL WIRING LABEL LABEL HERE LABEL HERE i I CHANNEL- SEE :mimmii CHANNEL- SEE i O 1 NOTES I&2 �� T+�1 NOTES I&2 O C) MODULAR LABEL MODULAR .-[ CH ; /LABEL E LABEL ,. ii ., i II DIS, !k:;E2SEE 11 He alt h : F11;r1 a E 7 NELSEE I ` � { Y MI a , I ! ` Z ¢ II `IzO��� =�CIEM7. C o o 1!71 . I 1STORE Num CORAL, INC. - el- L ) / o / 0 1 i 7358 S W DURHAM RD. COMPONENTS LABEL HERE IL LABEL HERE (1)SINGLE GANG STAINLESS STEEL WALL PLATE WA W C PORTLAND, OR 97224 (FOR WALL PHONES) 1 1 PROJECT TYPE MARIAM (1)CATEGORY 6 MODULAR JACK(WHITE) . V LEFT HAND WALL ORIENTATION RIGHT HAND WALL ORIENTATION LEFT HAND WALL ORIENTATION RIGHT HAND WALL ORIENTATION COMPONENTS TV CARE TV117 ! DEAL TYPES IfR NOTES NOTES (1)ALLENTEL#AT63OA WALL PHONE PLATE NOTES: (1)SINGLE > CS PROJECT NUMBER0106369 1. FURNITURE FACEPLATE SHALL BE INSTALLED AT DESK 1. FURNITURE FACEPLATE SHALL BE INSTALLED AT DESK (STAINLESS STEEL) COMPONENTS GANG STAINLESS STEEL WALL PLATE(FOR 1. REMOVE BLUE PLASTIC PROTECTIVE COATING HEIGHT AND AT THE CORNER OF THE FURNITURE AS COMPONENTS HEIGHT AND AT THE CORNER OF THE FURNITURE AS NOTES: WALL PHONES) FROM PLATE PRIOR TO MOUNTING TO WALL. • COMPONENTS F3 DEPICTED ON FLOOR PLANS. (1)FURNITURE BEZEL ORTRONICS PART#OR-4070071 F DEPICTED ON FLOOR PLANS. (1)CATEGORY 6 MODULAR JACK(WHITE) 2. WHEN MOUNTING TO WALL,ENSURE THAT TV COMPONENTS CARE TV COMPONENTS 1.REMOVE BLUE PLASTIC PROTECTIVE COATING FROM PLATE PRIOR TO MOUNTING TO WALL. SHORT(S)DO NOT OCCUR DUE TO OVER (1)SINGLE GANG 6-POSITION FACEPLATE(WHITE) (1)SINGLE GANG 6-POSITION FACEPLATE(WHITE) (1)FURNITURE BEZEL ORTRONICS PART#OR-4070071 2. INSTALL FACEPLATES TO ASSURE THAT LABEL (1)FURNITURE FACEPLATE ORTRONICS PART#OR-02100054 2. INSTALL FACEPLATES TO ASSURE THAT LABEL (1)STAINLESS STEEL ALLENTEL#AT63OA WALL PHONE (1)FURNITURE FACEPLATE ORTRONICS PART#0R-42100054 ORIENTATION READS FROM RIGHT-TO-LEFT WHEN (2)CATEGORY 6 MODULAR JACKS(BLACK) ORIENTATION READS FROM RIGHT-TO-LEFT WHEN 2.WHEN MOUNTING TO WALL,ENSURE THAT SHORT(S)DO NOT OCCUR DUE TO OVER TIGHTENING OF PLATE TIGHTENING OF MOUNTING SCREWS (1)CATEGORY 6 MODULAR JACKS(WHITE TO AV DROP) (1)CATEGORY 6 MODULAR JACKS(BLACK) MOUNTING SCREWS 3. TERMINATE BLUE PAIR TO CENTER PINS OF JACK (1)HDMI FEMALE TO FEMALE OR-KSHDMI(TO AV DROP) (5)BLANK INSERTS(WHITE) ARCHITECT OF RECORD (3)CATEGORY 6 MODULAR JACKS(BLACK) FACING FURNITURE WALL PLATES. (1)BLANK INSERT(WHITE) FACING FURNITURE WALL PLATES. 3.TERMINATE BLUE PAIR TO CENTER PINS OF JACK (4)BLANK INSERTS(WHITE) i . s THREE PORT FURNITURE INFORMATION OUTLET 4 STANDARD FURNITURE INFORMATION OUTLET 3 WALL PHONE INFORMATION OUTLET 2 WALL PHONE INFORMATION OUTLET - 1 AV WALL TO TV/CARE TV INFORMATION OUTLET 1 1 LABEL HERE LABEL HERE LABEL HERE LABEL HERE LABEL HERE LABEL HERE v = i 7, I l = 1 [ I [ 1 [ I [ I i 1 1 [ 1 1 p 0 di. ;El IN T 4 \'LABELHERE� AV AV [ I I O l I [ = 0 0 ® . ri , iri 1 CI C A 19 n IF 1 CONSULTANT: 71 I uu I I • _ � , � !1=1 1' iri 9074‘, OT jj• LABEL HERE LABEL HERE LABEL HERE LABEL HERELABEL HERE LABEL HERE[ IABEngineers+ to .1,. I - /� ` Consultants t AV 6 3 4 1 IC V V V V V 155 SEAPORT BOULEVARD • COMPONENTS COMPONENTS 1 DROP COMPONENTS SEAPORT WEST, FLOOR 2 (1)WIREMOLD 8ATCxxx BOX(BY OTHERS) (1)SINGLE GANG 6-POSITION FACEPLATE(WHITE) (1)WIREMOLD 8TRAC DEVICE PLATE (1)SINGLE GANG 6-POSITION FACEPLATE{WHITE) (1)CATEGORY 6 MODULAR JACKS(BLACK) BOSTON, MA 02210 F B4 COMPONENTS COMPONENTS COMPONENTS (4)CATEGORY 6 MODULAR JACKS(BLACK) {�11, (2)CATEGORY 6 MODULAR JACKS(BLACK DATA) (1)CATEGORY 6 MODULAR JACKS(WHITE TON) {SJ BLANK INSERTS(WHITE] cOP. 617.443.4950 F. 617.443.4959 (1)SINGLE GANG 6-POSITION FACEPLATE(WHITE) (1)SINGLE GANG 6-POSITION FACEPLATE(WHITE) (1)SINGLE GANG 6-POSITION FACEPLATE(WHITE) C SINGLE SINGLE Ts GANG 6-POSITION FACEPLATE(WHITE) IC DROP COMPONENTS (1)HDMI FEMALE TO FEMALE OR-KSHDMI{TO N} (6)CATEGORY 6 MODULAR JACKS(BLACK) (3)CATEGORY 6 MODULAR JACKS(BLACK) (4)CATEGORY 6 MODULAR JACKS(BLACK) (1)SINGLE GANG 6-POSITION FACEPLATE(WHITE) (2)CATEGORY 6 MODULAR JACKS(BLACK) (2)BLANK INSERTS(WHITE) (3)BLANK INSERTS(WHITE) (2)BLANK INSERTS(WHITE) (1)CATEGORY 6 MODULAR JACKS(GREEN) {4)BLANK INSERTS(WHITE) (5)BLANK INSERTS(WHITE) [ 10 FLOOR BOX OUTLET TYPE FBAV 9 AV INFORMATION OUTLET ( s J STANDARD 6 PORT INFORMATION OUTLET 7 STANDARD 3 & 4 PORT INFORMATION OUTLET 6 STANDARD 1/IC & 2 PORT INFORMATION OUTLETS DEVELOPER' I ) ` 1 00 05 PATCH PANEL PORT# TELCOMM ROOM IDENTIFIER CI LABEL SHALL MATCH ,— ,— WALL PLATE LABELS. r ..,,o, lo1^_-.['_'.^ --:"��f_ _?-'-'fit?. "'.-'-_T-1-! 7 ►4"'_i_:-�Y -:-!-!-!. ' '1".'-"'C" 1 r 1110 PANEL 00 ---- ---, - --- T111---•._--• - -.-...=Ly! PANEL 05 �-•--_- -...-r.- � 'ILS 1111tQ 1100 1' NOTES ` �i \i 0 . Y'-T �---r t o..,---. . -•-r 7 _.-...�.. `7—___, • 01 1.EACH JACK LOCATION WILL BE REPRESENTED 8Y A4 DIGIT LABEL EACH CABLE 41,0' PANEL 01 ---- „ PANEL 06 � ----- - NUMBER WHICH IS INDICATIVE OF THE PANEL AND PORT AT PATCH PANEL END ilk, ,,,,,li " ` POSITION RELATIVE TO THE CABLES ORIGIN. THERE SHALL Q 'gill ,. ,...si M fir.IOUO y I.,.- -r Wag nag—r-- 1 BE NO SPACES OR ADDITIONAL CHARACTERS PRECEDING, . SEAL'PANEL 02 —I.- - PANEL 07 - FOLLOWING OR BETWEEN NUMBERS. REAR OF PATCH PANEL • P7------ • PANEL 03 1 r __"_ii PANEL OS _7- - thailiMil . IF 7"..-•-•-3-4.-.- ----- ----- .._.r.....-+i .... i o _ _ _ _ O I C = 1 = li PANEL 04 ... -. (. ----.1-...--.) • PANEL 09 - --^r -Tr,-' __= --r-- - O v 1 I� �I P IV V V V IV ILLi O BLANKING PANEL TYP • Q 1 11 i OA CAM ABOVE CEILING MOUNT DATA RACK 1 DATA RACK 2 � 7"7"7"VV 7PPPPP� V IP CAMERA O ' �I�� �� ( 1 LABEL EACH CABLE AT p I� 1 L �� I O LTES: .�'J r IL IJ WORKSTATION END,APPROX. 1.N0 EACH PATCH PANEL WITHIN AN MDF/IDF SHALL HAVE A UNIQUE IDENTIFIER. LABEL EACH = 10"FROM END OF CABLE AP WIRELESS ACCESS POINT RACK-MOUNTED PATCH PANEL SEQUENTIALLY STARTING WITH"00","01","02",ETC...,WORKING FROM _ THE TOP DOWN ON RACK 1 AND FROM THE TOP DOWN AND LEFT TO RIGHT FOR REMAINING RACKS IN AP (Rx) PHARMACY NETWORK ALL ROWS. XXXX I XX XXXX n 2. COORDINATE WITH OWNER/CONSULTANT PRIOR TO LABELING HARDWARE. REVISIONS: 3. FOR THOSE LOCATIONS WITH TWO OR MORE RACKS(SWITCHES)PATCH PANEL STATION CABLING SHALL NOTE: NOTE: COMPONENTS NOTE: COMPONENTS q BE PATCHED BY ALTERNATING RACKS AS FOLLOWS: PANELOO,PANEL 05,PANEL 01,PANEL 06,PANEL 02, 1. LABEL FONT SHALL BE AERIAL BOLD SIZES. 1. CABLE LABELS SHALL MATCH FACEPLATE LABELING. EACH INDIVIDUAL CABLE {1)TRACJACK SURFACE HOUSING BOX 1.CABLE MUST HAVE 20'SLACK. (1)TRACJACK SURFACE HOUSING BOX ISSUED FOR BID—PERMIT 06.06. 17 PANEL 07 ECT. PATCH PANEL PORT IDENTIFIER LABEL SHALL CONTAIN IT'S SPECIFIC PORT LOCATION ON THE PATCH PANEL. (1)CATEGORY 6 MODULAR JACKS(BLACK) (1)CATEGORY 6 MODULAR JACKS(BLACK) E (1)BLANK INSERT(WHITE) (1)HDMI FEMALE TO FEMALE OR-KSHDMI(TO PROJ.) CJn ' IR ' 15 PATCH PANEL LABLING DETAIL ( 14 PATCH PANEL LABLING DETAIL ( 13 ] WALL PLATE LABLING DETAIL 12 CABLE LABELING DETAIL 1 11 j WIRELESS ACCESS POINT OR IP CAMERA OUTLET M c S I 09 -ROW M-RACK• 0411:01M1.1.1710 Oy I g LABEL ALL RACKS TO • C9 INDICATE ROW#AND .• 61 RACK#SEQUENTIALLY0 0 g LABELING RACK 4U FIBER OPTIC ADAPTER PANEL BEGINNING WITH ROW • lU FIBER OPTIC ADAPTER PANEL PATCH PANEL (TYPICAL) C 1,RACK 1 AND .; � PATCH PANEL (TYPICAL) 0 WORKING FROM LEFT ®�.... L TO RIGHT. O LABEL EACH CABLE AT PATCH PANEL LABEL EACH CABLE AT PATCH PANEL O PANELA PANELB 0{� PANEL C DRAWING BY: ' END. THE CABLE LABEL AT THE REAR END. THE CABLE LABEL AT THE REAR EOF THE PATCH PANEL SHALL OF THE PATCH PANEL SHALL CLEARLY IDENTIFY THE CABLE CLEARLY IDENTIFY THE CABLE J • SOURCE DESTINATION ROW,RACK, SOURCE DESTINATION ROW,RACK, -a Ja 00 "' J J J J DATE: June 06, 2017 FRONT OF REAR OF PATCH PANEL PANEL&PORT. FOR EXAMPLE A PANEL&PORT. FOR EXAMPLE A REAR OF PATCH PANEL 2U FIBER OPTIC ADAPTER PANEL z z z z w z z Li) Z z z z T CABINET/RACK (ROW 1) CABLE INTERCONNECTED FROM CABLE INTERCONNECTED FROM (ROW 2) PATCH PANEL , - a a a a a a a d a a 6.. a �+ (TYPICAL) a a a . ORT 02 TO ROW 2,RACK 3,PANEL OW 1,RACK 3,PANEL A, A,PORT ROW 2, CK 3,PANEL A,PORT 02 TO ROW 1A RACK 3,PANEL A,PORT Ct a 1• JOB NUMBER: 02GPD-170493 02 LABEL WOULD BE LABELED 02 LABEL WOULD BE LABELED • • 1 $D 0 8 TITLE: a "2-3-A-02". 1-3-A 02". PANELA PANEL B PANEL C y,r: uxatnt 3 €t 1 L PANEL 0 PANEL E PANEL F f I ; t Ci TELECOMMUNICATIONS 61 I DETAILS 52 •'N SHEET liIs ,T NOTE: c . d 1. LABEL FONT SHALL BE AERIAL BOLD SIZE S. p�,, 2. FIBER OPTIC INTERCONNECT LABEL IS SIMILAR TO COPPER EXCEPT THE FIBER PANEL PORTS WILL ARE DESIGNATED WITH A PANEL PORTS 3 o N LETTER FOLLOWED BY A PORT ID#. T _ d ,.. --1 �r_ d _ _ m 19 CABINET/RACK LABELING DETAIL 18 INTERCONNECT CABLE LABELING SCHEME 17 ) FIBER OPTIC ADAPTER PANEL IDENTIFICATION DETAIL 16 4U FIBER OPTIC ADAPTER PANEL IDENTIFICATION DETAIL COMMENTS: II II c 4 gS © yr " 111/1°CVS 1 TELECOMUN ROUNDING 0 HORIZONTAL GROUND BAR KIT ORTRONICS :- © © BUSBAR{TGB)(BY CATIONS CAL CONTRACTOR PART#GBH19KIT MOUNTED TO BACK OF RACK/CABINET. COORDINATE MOUNTING GROUND CONNECTION FOR EQUIPMENT. HEIGHT WITH OWNER/CONSULTANT PRIOR TO 2 HOLE COMPRESSION LUG. UTILIZE INSTALLTION. TONGUE OF CONNECTOR TWO HOLE COPPER COMPRESSION BOTH HOLES FOR CONNECTION. • TYPE GROUND LUG WITH :. .: tl 20 PROVIDE AND INSTALL#6AWG GROUND INSPECTION WINDOW WIRE TO TGBB. EQUIP WITH 2 HOLE INSPECTION HOLE . . P! CABLE RUNWAY COMPRESSION LUG AT EACH END. ROUTE TIN-PLATED TWO HOLED mEm.GROUND STRAP ALONG CABLE TRAY TO TGBB STAINLESS STEEL He alit h COPPER COMPRESSION LUG BOLT,NUT AND CABLE RUNWAY M WITH INSPECTION WINDOW. WASHERS �/ SPLICE O PROVIDE AND INSTALL#14 AWG GROUND O O (THOMAS&BETTS{T&B)OR 0 0 0 0 0 0 0 0 0 0 0 0 0 0 /�i WIRE TO EACH PIECE OF PASSIVE BURNDY) "' • [4'�� TELECOMMUNICATIONS EQUIPMENT � 0 0 0 0 0 0 0 0 0 0 0 0 0 0 MOUNTED IN RACK. •s ■■ EQUIP WITH MANUFACTURER SUPPLIED BACK OF0 DIE INDICATOR EMBOSSED INTO CRIMP RING TERMINALS AT THE GROUND BAR CABINET/RACK DOUBLE HEX CRIMP FLAT WASHER GROUND O O O O END. EQUIP WITH SPADE STYLE GROUND BA' LOCK WASHER CONDUCTOR TERMINALS AT THE EQUIPMENT END. 0 0 0 0 0 0 0 0 • 0 0 0 CORAM, INC.STORE NUMBER • • 0000 0 0 0 0 0 0 0 0000 7358 S W DURHAM RD. I m I PORTLAND, OR 97224 NOTES: u FRONT ELEVATION hal PRO {�T TYPES PHARMACY - 1. REMOVE ALL FLASHES,BURRS,OR SHARP EDGES AFTER CRIMPING. DEAL TYPE 2. 2-HOLE BOLT TYPE COMPRESSION CONNECTORS SHALL BE UTILIZED WITH ALL ALL CONDUCTORS;MECHANICAL MII LUGS(E.G.,ALUMINUM/STEEL SET SCREW TYPE)ARE STRICTLY PROHIBITED. LUGS SHALL BE T&B OR BURNDY LUGS SIZED NO.6 AWG AND LARGER AND MUST HAVE INSPECTION HOLES TO VERIFY THAT THE CONDUCTOR IS NOTES PROJECT �; 0�06369 • FULLY INSERTED INTO THE BARREL OF THE LUG. HYDRAULIC COMPRESSION TOOLS SHALL BE UTILIZED TO 1. GROUND WIRE$$HALL BE NEATLY BUNDLED AND SECURED TD THECS PROVIDE THE CORRECT CIRCUMFERENTIAL PRESSURE FOR PROPER INSTALLATION. USE TOOLS AND DIES THAT BACKBOARD AND CABLE TRAY. ARE SPECIFICALLY RECOMMENDED BY THE CONNECTOR MANUFACTURER(I.E.,T&B OR BURNDY ONLY), 2. FRONT AND BACK FACE OF THE GROUND BAR MAY BE UTILIZED AS NECESSARY NOTES: • PROVIDE EMBOSSING DIE CODE TO MAKE A 45 DEGREE VISIBLE INDICATION THAT CONNECTOR HAS BEEN TO ACCOMODATE ALL REQUIRED GROUND CONNECTIONS. 1. INSTALL CABLE RUNWAY GROUNDING STRAP AT EACH SIDE OF LADDER ADEQUATELY COMPRESSED ON A CONDUCTOR. ARCHITECT OF RECORD RACK WHEREVER A SPLICE IS INSTALLED. �R 5 LADDER RACK GROUND STRAP DETAIL 4 CABINET/RACK GROUNDING DETAIL 3 j GROUND LUG DETAIL 2 TYPICAL TGB CONNECTION DETAIL 1 TYPICAL TGB ELEVATION DETAIL �� O. TERMINATE TELECOMMUNICATIONS BONDING BACKBONE:TBB ONLY DIRECTLY ONTO BUSBAR AT FURTHEST .�. POINT OR RISER CABLE BUNDLE FROM 0 ,.........„....-4. '� 02 INSTALL MINIMUM AWG#6 VIA IRREVERSIBLE SPLICE CONNECTION TO THE TGB LADDER RACK STORE �+1 .. CABLE BUNDLE MIN 10'ON LADDER �/ .�I . .' TURN DOWN INTO RACK 3/8"THREADED 24"LADDER RACK 03 ADDITIONAL BONDING CONDUCTOR FROM THE BUSBARS TO BUILDING STEEL AT CLOSEST POINT VIA : RACK \ � CHANNEL 3/8"THREADED ROD SUPPORT IRREVERSIBLE CONNECTION,BY E.C. �` ..., ROD SUPPORT •` SECURED TO 24"LADDER RAC SECURBUILDING. , 4% THEBUILDING. WALL ANGLE SUPPORT BRACKET STRUCTURE % % • el i\i\,\1• i\! STRUCTURE GENERAL NATE: —TGB— TELECOMMUNICATIONS GROUNDING `i+,, ,1: ROUTE CABLE BUNDLE I' 145/7.Z,7- Z/ j /17//11��.7/, � � 7WALL ANGLE SUPPpRT BRACKET PROVIDE GROUND LUGS THAT ARE SINGLE BARREL,2 BOLT BUSBAR DIRECT TO BACK OFi1 / SERVER DISTRIBUTION RACK--m•--, 1\,, PATCH PANEL(S) '� '"� / ' ` ATTACHMENT —TBB— TELECOMMUNICATIONS BONDING \ %. ,\± �/ f��f I �, 00 • TYPICAL BONDING OF BACKBONE `,I ,, M • CABLE TRAY . i I I \, SECTIONS • \' ♦ TAiVT 4%0 \ , r `\,i�' `\`4 / .... .. 1/2 INCH EMT �- 2 HOLE COMPRESSION LUG 1\,\\! ,,\\; _ `/ THREADED #6 AWG INSULATED,GREEN COLOR FOR#6 AWG.BOLTED TO TRAY. GROUNDING `1' i\ A%0 ' ROD COVER ! 1/2 INCH EMT EQUALIZER TBB(BY E.C. �, �;iFRONT OF RACK / (TYPICAL) THREADED #6 AWG INSULATED,GREEN COLOR (BY E.C.) J TELECOMMUNICATIONS k\\i,3 . %ON? ROD COVER 1+\,,\ \\,,,; / (TYPICAL) \ CABLE TRAY ( ) —�'"'�r GROUND BUSBAR(TGB) ` Engineers+ #6 AWG.COPPER,BOLTED TELECOMMUNICATIONS J � Consultants :'0:0 \,\; ,, TO TRAY ON BOTH SIDES GROUND BUSBAR(TGB) 0 RACKS , '/, /4///////////4/// 7/��� HORIZONTAL GROUND BA' LOCK WASHER AND NUTS O SHALL BE ON OUTSIDE OF TRAY NOTES ORTRONICS PART#GBHI9KIT TWO HOLE COMPRESSION LUG © O NN, 1. ALL SECTIONS AND COMPONENTS OF LADDER RACK SYSTEM SHALL BE (TYPICAL) NOTES ELECTRICALY BONDED AND GROUNDED TO THE E.C.PROVIDED NOTES LBOSTON, 5 SEAPORT BOULEVARD 1.CABLES SHALL BE NEATLY BUNDLED AND DRESSED TIGHT TO CORNERS OF THE INSIDE CHANNEL OF THE RACK TELECOMMUNICATIONS GROUNDING BUSBAR 1. ALL SECTIONS AND COMPONENTS OF LADDER RACK SYSTEM SHALL BE TWO HOLE COMPRESSION LUG © TGB APORT WEST, FLOOR 2 I TOP TO REAR OF PATCH PANEL AS SHOWN. SECURE TO RACK WITH HOOK AND LOOP FASTENER WRAP(i.e., CABLE TRAY ELECTRICALY BONDED AND GROUNDED TO THE E.C.PROVIDED (TYPICAL) T-361 © \--TGB(BY E.C.) VELCRO WRAP). 2. LADDER RACK SHALL BE SUPPORTED TO THE OVERHEAD SLAB AND AT TELECOMMUNICATIONS GROUNDING BUSBAR MA 02210 2.CABLES SHALL BE SPLIT INTO TWO(2)EQUAL BUNDLES AND ROUTED DOWN INTO THE RACK ON THE SIDE AT EACH END EXCLUSIVELY. TRIANGULAR SUPPORT BRACKETS ARE 2. ADDER RACK SHALL BE SUPPORTED TO THE OVERHEAD SLAB AND AT 443.4950- F. 617.443.4959 ) ' WHICH THE CABLES APPROACH THE RACK. EXPRESSLY FORBIDDEN EACH END EXCLUSIVELY. TRIANGULAR SUPPORT BRACKETS ARE IDE/MDF 3.SEE SPECIFICATION DOCUMENT FOR SPECIFIC PATCH PANEL CABLE DRESSING REQUIREMENTS. — 3.PROVISION EMT THREADED ROD COVER WHEREVER THREADED ROD IS UTILIZED EXPRESSLY FORBIDDEN. 3. PROVISION EMT THREADED ROD COVER WHEREVER THREADED ROD IS UTILIZED • INR 9 TYPICAL SERVICE LOOP INSTALLATION DEVELOPERS 6 ACK CABLE ROUTING DETAIL [ J LADDER RACK MOUNTING AND GROUNDING DETAIL 7 LADDER RACK MOUNTING AND GROUNDING DETAIL 6 MDF/tDF/PUC GROUNDING DETAIL E 3/4"AC GRADE VOID FREE PLYWOOD BACKBOARD. PAINT WITH FIRE RATED GRAY PAINT. SLAB H H r C THREADED DROPS,_____w___, ROD(TYPICAL) (TTP) i v ° o° °v ° d ° 1/4"DIA.S/S THREADED ROD 4"LONG HELD IN HILT(HIT C-20 CHEMICAL ANCHOR / CABLE TRAY VERTICAL WALL DRILLED INTO MASONRY WITH S/S WASHER s/ CEILING FRAMING STUD AND NUT. f Q ' f . AM / f .. SLEEVE/CONDUIT(TYPICAL) FRFObTERING(TYPICASTUDL) (TYPICAL) .� 12 MIN. « sEAL o \\\\\\\\\\�;•\ \\\\\\\\\\\„,„,„....\\\\\\\\\\\\\\ ,,,\\\\\\\\\\\\\\\\\\\\\\\` r4” �. T •rr4 • �7 DRAG WIRE/STRING 72” I • SIZE TO SUIT NO.CONDUITS (TYPICAL) 3/4”AC GRADE VOID TOP VIEW FREE PLYWOOD BACKBOARD. . UNISTRUT PIPE/CONDUIT CLAMPS P2558 FULL HEIGHT CEILING HIGH OR EQUAL.PARTITION PARTITION WALL FRAMING STUD(TYPICAL) ' —' PIPE OR CONDUIT CABINET RACK (TYPICAL) (TYPICAL) 84"APE 4- 1•i..•••••m) + UNISTRUT P1000(OR EQUAL)1 5/8"x 15/8" SINGLE GANG S..-4 ��; }L WITH HOT-DIPPED GALVANIZED FINISH MUD RING - MASONRY WALL BEYOND SLAB (TYPICAL} NOTES 18 AFF 1. HORIZONTAL(CROSS)STUDS SHALL NOT BE UTILIZED TO SUPPORT BACKBOARD. . J 2. COORDINATE DESIRED DEPTH BEHIND PLYWOOD WITH OWNER PRIOR TO ° P _ INSTALLATION a NOTES REVISIONS: 1. HORIZONTAL(CROSS)STUDS SHALL NOT BE UTILIZED TO SUPPORT BACKBOARD. 2. COORDINATE DESIRED DEPTH BEHIND PLYWOOD WITH OWNER PRIOR TO ISSUED FOR BID—PERMIT 06.06.17 INSTALLATION 3. MINIMUM 10 OUTLET POWER STRIP EVERY 8'BY E.C. NOT TO SCALE la rei [ 1s TYPICAL RING AND STRING FOR 14 l TYPICAL PLYWOOD BACKBOARD MOUNTING DETAIL [ 13 PLYWOOD BACKBOARD MOUNTING DETAIL 12 WALL MOUNT CONDUIT SUPPORT DETAIL ii LADDER RACK ELEVATION DETAIL VOICE AND DATA OUTLETS IN OFFICE AREA c rWALL Q • C a V LIQUID TIGHT NON-MET e e FLEXIBLE TUBING ASHER FURNITURE PARTITION [BUSFNGSC INSULATIEI4 Q- a FURNITURE PARTITION FURNITURE PARTITION WALL MOUNTED STAINLESS STEEL / d' d ' FIRE RATED WALL ELECTRICAL FACEPLATE TO ` I- ACCEPT SYSTEM INFEED(TYPICAL) 1 r ir LIQUID TIGHT LIQUID TIGHT r II NON-METALLIC NON-METALLIC C / q q \ C FLEXIBLE TUBING FLEXIBLE TUBING a / . a // CONDUIT GROMMETED CORE ` GROMMETED CORE ameasamalameam THROUGH FLOOR THROUGH FLOOR B e TILE(BY OTHERSDRAWING BY: E / d n Ill , ) 1tttttliilll1111111111i1�7 TILE(BY OTHERS) ID a EMT CONDUIT v �� \ E1M \"1�ttrtlllllllllllllllnt� June 0 , 2017 FLOOR LINE .1111(1111 MO RI FLOOR LINE DATE: s / / h oWASSIMMOBWAI 411161 P o h o P P HEIGHT PER —.4-4.--,..axz�,.:��-------._..:..... ..................... . .� 4 FIRE STOP MATERIAL RAISED FLOO�t rIb SLAB a v ARCH.DWG. JOB NUMBER: 02GPD-170493 J e % - n 4 y . Ill SLEEVE n FINISHEpFLOOR� . —� / DATA CABLES TEL/DATA INFEED LOCATION ' TEL/DATA INFEED LOCATIdN �{ TITLE: ~ / SUPPLIED BY FURNITURE VENDOR. SUPPLIED BY FURNITURE VENDOR. INSTALLED BY TELCOM.CONTRACTOR TEL/DATA INFEED JUNCTION BOX INSTALLED BY TELCOM.CONTRACTOR BY TE LE C 0 M M U N I C A TI O N S g• a / TELEPHONE/DATA CABLES SNSTALL�D BY TE CIOM.CONTRACTOR C7 1 4 v a a G NOTES NOTES NOTES DETAILS p Cr) STEEL 1. THIS IS ATYPICAL FURNITURE SYSTEM DETAIL AND IS INTENDED TO INDICATE GENERAL 1. THIS IS ATYPICAL FURNITURE SYSTEM DETAIL AND IS INTENDED TO INDICATE GENERAL 1. THIS ISA TYPICAL FURNITURE SYSTEM DETAIL AND IS INTENDED TO INDICATE GENERAL —N g SLIDING INSTALLATION REQUIREMENTS ONLY. REFER TO ARCHITECTURAL DRAWINGS&MANUFACTURER'S INSTALLATION REQUIREMENTS ONLY. REFER TO ARCHITECTURAL DRAWINGS&MANUFACTURER'S INSTALLATION REQUIREMENTS ONLY. REFER TO ARCHITECTURAL DRAWINGS&MANUFACTURER'S SHEET NUMBER: to N• LOCK WITH INSTALLATION DETAILS FOR SPECIFIC FURNITURE SYSTEM INFORMATION. INSTALLATION DETAILS FOR SPECIFIC FURNITURE SYSTEM INFORMATION. INSTALLATION DETAILS FOR SPECIFIC FURNITURE SYSTEM INFORMATION. r. p 4 q b SET 2. CONDUIT/TUBING SHALL BE SIZED AS FOLLOWS:3/4"C FOR 1WORK STATIONS;1"C FOR UP TO 2 2. CONDUIT/TUBING SHALL BE SIZED AS FOLLOWS:3/4"C FOR 1WORK STATIONS;1"C FOR UP TO 2 2. CONDUIT/TUBING SHALL BE SIZED AS FOLLOWS:3/4"C FOR 1WORK STATIONS;1"C FOR UP TO 2 N A OR WORK STATIONS;1-1/4"C FOR UP TO 4 WORK STATIONS&2"C FOR UP TO 9 WORK STATIONS. WORK STATIONS;1-1/4"C FOR UP TO 4 WORK STATIONS&2"C FOR UP TO 9 WORK STATIONS. WORK STATIONS;1-1/4"C FOR UP TO 4 WORK STATIONS&2"C FOR UP TO 9 WORK STATIONS. 41$ CAI 0 APPROVED t v EQUAL T _ /1 , 2 1' et 31 CONDUIT PENETRATION THROUGH MODULAR FURNITURE SYSTEM MODULAR FURNITURE SYSTEM COMMENTS: 11 11 E 20 WALL PENETRATION SLEEVE DETAIL 19 1/ 16 MODULAR FURNITURE SYSTEM WALL FEED DETAIL FIRE RATED WALL 18 RAISED FLOOR FEED DETAIL SLAB POKE THROUGH FEED DETAIL =L2 M __.... - _- ......... ..w....... - __." .. _. F , -_... _ ,...-.n . ... -. - , .. _ .. , , _ ._....,-----_________.-..o...., , w..,.. .__ .-- ___ -- ... ..-- ._... . -- 1 • /� . 14110 CVS ! �� ilk , WIRE 40' 1 �� MESH 1/21NCHEMT CABLE i' / 4,e-- , THREADED Kolio001.41 TRAY / l� % /,- '� � ,ii,"--- �' � Ron COvER J ' —FASP �� .4.. (TYPICAL) I' ' \ i0. 101 •�:•• •.•♦ate /• J ' He alt h „, . ,,....._ iih......;_„.... SVVK /et ....-'-.., rte_ �I _,,, �,��`' _ !�`_ 40� � J �� \� �:'�� .�`� J THREADED I,� ' �, ��i `'I' !a\- .. ,,_�. �I► ROD ' -\_.�� �\ STORE NUMBER: !• " �, J /I i' r / 4 rel . i i �._ � /� l dam_ I �- I, ! ! 'I LDHN EZFW CORAM, INC. / Li ``� . � /,, • �� J FASP ; ' 7358 S W DURHAM RD. I \� J . EZHN `` RAOT90 �� / �� �I �- PORTLAND, OR 97224 'jam' BRACKET �i/ /��� �� . 1011„ `I, ` WiTH 5"RADIUS �' � ' ► CNT TVI . PHNIIAACY I -' ` PROJECT TYPE: /IiJiii � DEAL TYPE Mit � Imo, J �1 C S PROJECT NUMBER 0106369 . 1 NOTES: 1. ONE"RADT90"KIT MAKES ONE'TEE'OR TWO SWEEPS NOTES: NOTES: NOTES: NOTES: 1. MESH CABLE TRAY INSTALLED BY CONTRACTOR 1. MESH CABLE TRAY INSTALLED BY CONTRACTOR 1. MESH CABLE TRAY INSTALLED BY CONTRACTOR 1. MESH CABLE TRAY INSTALLED BY CONTRACTOR 2. PROVISION THREADED ROD COVER WHEREVER THREADED ROD IS UTILIZED ARCHECT OF RECORD 1 5 CABLE TRAY HORIZONTAL SWEEP DETAIL ( 4 EDRN FAST SPLICE INSTALLATION DETAIL 3 SWK SPLICE WASHER KIT INSTALLATION DETAIL 2 ) TRAPEZE HUNG FASP CEILING MOUNT DETAIL ( UNDERFLOOR FASP PROFILE MOUNT DETAIL . ( I I EZ BN CABLE CHASE WIRE MESH • CAT6 CABLE IN CEILING CABLE TRAY WALL CB25 UN€STRUT PATHWAY UNISTRUT CABLE TRAY 0 1/2 INCH E 6"RAISED FLOOR THREADED ROD COVER _ ALL (TYPICAL) + CABLE DROP .."'.. .-1111111.10404..01 `�1111141, WALL MOUNTED SIDE VIEW OUT LIIIIII LADDER RACK SECURE CABLE DROP OUT /`4�� l FASCLM KIT N CEILING TO WALL WITH APPROVED ` a� GROUND LUG C f- �' FIBER DUCT W/D FASTENERSIS iI I I '..,..4411.1.'". ` a� FIRE STOPS THRU-WALL FOR ACCESS TO . - COVER ".111. r WIRE MESH SECTION A A ` ``�� / CABLE TRAY. ALL FIRE STOPS SHALL BE ��40,......... � ~�+j CABLE TRAY WALL CABLE DROP \�` �'N.:0•0000, • j III FIRE PROOFED AS REQUIRED BY ALL '/� i tliti FLOOR CUT-OUT ` `!`•! 1 BE SIZED TO MEET SAME CABLE FILL AS �i LIN BY OTHERS OUT `` `` �� � APPLICABLE CODES. FIRE STOPS SHALL - �-•. : CONSULTANT• 1 \�`/ �I ' TRAY SYSTEM. -1� t�_ AISED FLOOR / �)♦(♦(♦(♦(♦=�=(♦(♦���� STRUCTURE A %i ,,41,''' �� � - �1J� ======Ill.♦NMI•==MI_ 1.5"/TYP. / /�'� �� i i�� . \ • =====I=MIME===== _ _ ,---� � � • a� Esc- �: �sli RAISED ACCESS 11111 �` , �� la .,� s 11 FLOORtill ��=(♦(♦(♦(♦(♦(♦�)♦==MT_ `�T`J \�``�•``�� << \1� - t THREADED \`'`� •�a 'l.�� - �^ RDD , 1AB Enc ineers+ P . -:�_ €OP VIEWI 2"X12"TRAY R6 AWG GROUND WIRE— •````'``` EZFW FASP Consultants 6"RAISED FLOOR LOW VOLTAGE 2"X20" EZHN UNDER FLOOR CABLE TRAY ELECTRICAL "GNDSB" NOTES: TRAY GROUNDING 1. CABLE DROP OUTS SHALL BE INSTALLED WHEREVER CABLING ENTERS OR EXITS THE END OF CABLE TRAY. I LUG 155 SEAPORT BOULEVARD FURNISH AND INSTALL IN SUFFICIENT QUANTITIES TO TRAVERSE THE ENTIRE WIDTH OF THE CABLE TRAY J SEAPORT WEST, FLOUR Z NOTES: / i_._1 `� WIRE— BOSTON, MA 02210 1. OVERHEAD CABLE TRAY SHALL BE TRANSITIONED TO BELOW RAISED FLOOR AT CABLE CHASE LOCATIONS. SECTION(LE,PROVIDE TWO 12 INCH DROPOUTS AT ENDS OF 24 INCH CABLE TRAY). FASP FLOOR MESH 2. CABLE DROP OUTS SHALL BE ATTACHED TO CABLE TRAY WITH A MINIMUM OF TWO(2)EZ BN AND TWO(2)CB CABLE NOTES: P. 617-443.4950- F. 617.443.4959 DIRECTLY CONNECT ALL CABLE TRAY SECTIONS UTILIZING MEANS AND METHODS RECOMMENDED BY• 25 FITTINGS. TWO OF EACH ARE PROVIDED WITH DROP OUT KIT FROM MANUFACTURER. BRACKET {1/T-403} TRAY 1. MESH CABLE TRAY INSTALLED BY CONTRACTOR TRAY MANUFACTURER. A 2. PROVISION THREADED ROD COVER WHEREVER THREADED ROD IS UTILIZED 10 CABLE TRAY CEILING TO FLOOR TRANSITION 9 J CABLE DROP OUT INSTALLATION DETAIL 8 UNDERFLOOR CABLE TRAY DETAIL 7 CABLE TRAY FIRE RATED WALL PENETRATION DETAIL 6 ) TRAPEZE HUNG FASP OBSTACLE AVOIDANCE DETAIL DEVELOPER' L _ W SIX(6)CATEGORY 6 CIRCUIT .6"D RING CABLES TO PUC ROW 1 RACK 1 (TYPICAL) SIX(6)CATEGORY 6 CIRCUIT f USE THIS CONFIGURATION NOT THIS CABLES Tp PUC ROW 3 RACK 1 J D I I I I o .■r�Millirere V 54"AFF t+ WALL PHONE/TIME CLOCK ;. 25 PAIR CATEGORY Pilyi 3 TO PUC ROW 1 3/4 INCH PLYWOOD RESERVED FOR VERIZON RACK 1 TELECOMMUNICATIONS PULL BOX • ` SEAL: BACKBOARD(BY OTHERS) i SURFACE MOUNT (25)PAIR 66STYLE SIZING SCHEDULE BOX WITH(6) BLOCK MOUNTED CATEGORY 6 JACKS ON 89-D BRACKET FOR CACI I {TYPICAL) MAXIMUM TRADE SIZE OF BOX ADDITIONAL 1 SIZE OF CONDUIT CONDUIT WIDTH LENGTH DEPTH 4 18"AFF 0 S INCREASE WIDTH s TELE/DATA OUTLET e 0 .• 3/4 4" 12" 3" 2" FINISHED FLOOR 1 4" 16" 3" 2" USE THIS CONFIGURATION NOT THIS RJ21X CABLE EQUIPPED WITH 74 8" 271 6" 20" 3" 3" MALE AMPHERNpL 1 " 4" 4" 18"MIN. NOT TO SCALE X CONNECTOR{PROVIDE A 10 19 FOOT COIL) 2 8" 36" 4" 5" -1-4.2 10" 42" 5" 6" r NOTES: (2 1. ALL DEVICES INSTALLED AS SHOWN U.O.N. i3 12° 48" 5" 6" 2. ALL MOUNTING HEIGHTS SHALL BE MEASURED FROM CENTERLINE OF DEVICE TO FINISHED FLOOR. 12 54' 6" 6" 3. DEVICES SHALL BE INSTALLED ON A COMMON VERTICAL CENTERLINE WHEREVER POSSIBLE. 1/2 REVISIONS: NOTES: 4 15" 60' 8" 8" 1. PROVIDE BRIDGE CLIPS AND LABELING STRIPS AT 66 BLOCKS AS REQUIRED. ISSUED FOR BID-PERMIT 06.06.17 rn 13 PUC - VERIZON WALL FIELD ELEVATION 12 ) TELECOMMUNICATIONS PULL BOX DETAIL12 INFORMATION OUTLET TYPICAL MOUNTING HEIGHTS mi 0 r• { ci COMMON SPEAKER p BACKBONE F- WALL PNFa 7 ANGLE CABOFIL PW CABLE TRAY + CAMP 1 Z SUPPORT CABOFIL PW CABLE TRAY ALUMINUM SOLID CORRIGATED (T ALUMINUM SOLID CORRIGATED EZ PATH BOTTOM L '6f BOTTOM ARE STOP SYSTEM 12"WIDE 4"DEEP(3"USABCC) 12"WIDE 4"DEEP + AMP? PAINPNH I-4 PA3/8 INCH HEX HE°: 1111111116 NUT WITH WASHER rsi (") riLISBA \\\\,111 k..s.. \ DRAWING BY: . SE OF RAC I • J ..._,_, , , ADHESIVE ANCHOR A �, r �� I I I I I I E _ EOM DATE: June 06, 2017 2.� - - - - - - � o n �. � �� � �; 6 o �, ** 6 � n o . 'n I : s 4 6 S T a •- ..11 JOB NUMBER: 02GPD-170493 S FIRE STOP Y (Y Y � Y Y M Y • Y (Y J Y Y V O 111-0 0 �0 IL VI-11. 0 I '" SYSTEM 0 O �R`,LO•R(6,10�_ �ry� �, �� ��� O ®.... U, U��O1 U UZUZ�0 OUO�UZU\' O� 3/8 INCH THREADED ' ;' J �. a � o. ]; � .o JACK POSITIONS . . - •Y '33/$INCH M�;::-'- TITLE: F- RCA JACK PANEL SIDE SECTION VIEW . TELECOMMUNICATIONS N r DETAILS 5 CMi KEYED NOTES THE ILLUSTRATIONS ARE FRONT VIEWS OF THE CONNECTOR.THE WIRE ;,.g N $ COLORS INDICATED ARE ASSOCIATED WITH THE STATION DISTRIBUTION `• SHEET NUMBER: O 3 ed PLAN VIEW SECTION VIEW 1 SPEAKER BACKBONE CONNECTIONS TORCA PANEL SHALL BE SOLDER TYPE CABLE. .. • c O CONNECTIONSOR SPADE TYPE CRIMP CONNECTIONS. ,• •• , # O RCA CONNECTORS WITHIN EACH DEFINED GROUPING SHALL BE BRIDGED ( >Z.,....-• TO PROVIDE MULTIPLE CONNECTION POINTS FOR EACH FLOOR AND AMPLIFIER. T _ /1 4... j liI- m 17 WIRE MESH TO SOLID BOTTOM CABLE TRAY WALL PENETRATION 16 ) PAGING RCA PANEL TERMINATION DETAIL 15 ) 8 POSITION JACK PAIR ASSIGNMENT (T568B) ( 14 ) RACK FLOOR MOUNTING DETAIL COMMENTS: __... .w..,... .. .. n u 0 • o LA- _