Report (16) CII � ' ' P '' -�De2 //7
0 /Y7 7...5 f 76 — ,,,z47---
-11
. 4- _ _- Nov 2 9 2018
GeoP c
Engineering.lnc. i �' . k j?:;a ,/
Real-World Geotechnical Solutions '."'" ?`N(
t' : 14835 SW 72K Avenue Tel (503) 598-8445
Investigation •Design •Construction Support Portland, Oregon 97224 Fax(503) 941-9281
DAILY FIELD REPORT
PROJECT DATE
Elderberry Ridge May 15,2018
PROJECT NUMBER WEATHER
15-4010 Partly cloudy,60s
CLIENT CONTRACTOR
Riverside Homes Saunders
PERMIT NUMBER PAGE#
-- 1 of 1
Inspection Notes: (Include location,testing data,substitutions/deviations,materials,and methods of construction,conformance statement,etc.)
TYPE OF OBSERVATION:
Engineered Fill
GeoPacific field technician Eric Merritt was on site to observe engineered fill activities at Lots 35-40 and the contaminated
soil excavation backfill near Lot 23. The excavation backfill had approximately a 2 foot lift placed and compacted with an
815 roller. Density testing and visual observations indicated adequate moisture content and compaction. Soil drying
operations for engineered fill at Lots 35-40 are ongoing. The strippings stockpile is currently located at Lots 35 and 36,
and no drying operations are being conducted here yet.
DISTRIBUTION LIST: OBSERVED BY:
Eric Merritt
REVIEWED BY:
JDI
GeoPacific Engineering, Inc. Signature
Information contained herein pertains to materials tested/inspected only. The fact that any particular work has been observed or tested does not waive
the contractor's responsibility for the means and methods of construction,job site safety,or to comply with the contract documents. This information
contained herein should be considered preliminary until review by the project engineer.
GeoPacific
Engineering.Inc.
Real-World Geotechnical Solutions 14835 SW 72nd Avenue Tel (503) 598-8445
Investigation • Design •Construction Support Portland, Oregon 97224 Fax(503) 941-9281
DENSITY TEST DATA SHEET
PROJECT SOIL DESCRIPTION DATE
Elderberry Ridge Onsite Native Silt Soils May 15,2018
PROJECT NUMBER WEATHER
15-4010 Partly cloudy,60s
CLIENT NUCLEAR GAUGE SERIAL# CONTRACTOR
Riverside Homes 34418 Saunders
PERMIT NUMBER METHOD OF TEST PAGE#
-- Troxler Gauge,T-99 1 of 1
FIELD FIELD DENSITY MAX.DRY COMP. COMP. OPTIMUM PASS
TEST
TYPE TEST LOCATION �FT� MOIST. (PCF) DENSITY SPEC. RESULT MOISTURE LAB ID OR
v.
WET DRY (PCF) % % % FAIL
LF
-Lot 23,excavation backfill, north +2 17.8 122.3 103.8 108.4 95 95.8 17.6 P18-073 P
half
LF
-Lot 23,excavation backfill,south +2 18.5 124.2 104.8 108.4 95 96.7 17.6 P18-073 P
half
TEST TYPE: LF=Lot Fill SF=Structural Fill ST=Sanitary Trench DT=Storm Trench WT=Water Trench RF=Roadway Fill
RW=Retaining Wall Backfill PS= Pavement Subgrade BC=Base Course FT= Franchise Trench
REMARKS:
GeoPacific was onsite to conduct density testing of structural fill at the locations referenced above. The excavation
backfill is approximately 10 feet deep, but this area receives a cut of 3 feet. Test results met project specifications for
compaction at the locations tested.
TESTED BY: Eric Merritt REVIEWED BY: JD!
Information contained herein pertains to materials tested/inspected only. The fact that any particular work has been observed or tested does not waive the
contractor's responsibility for the means and methods of construction,job site safety,or to comply with the contract documents. This information
contained herein should be considered preliminary until review by the project engineer.
GeoP cific
Engineering.Inc.
Real-World Geotechnical Solutions 14835 SW 72nd Avenue Tel(503) 598-8445
Investigation • Design •Construction Support Portland, Oregon 97224 Fax(503) 941-9281
DAILY FIELD REPORT
PROJECT DATE
Elderberry Ridge May 16,2018
PROJECT NUMBER WEATHER
15-4010 Partly cloudy,60s
CLIENT CONTRACTOR
Riverside Homes Saunders
PERMIT NUMBER PAGE#
-- 1 of 1
Inspection Notes: (Include location,testing data,substitutions/deviations,materials,and methods of construction,conformance statement,etc.)
TYPE OF OBSERVATION:
Engineered Fill
GeoPacific field technician Eric Merritt was on site to observe engineered fill activities at Lots 37-40 and the contaminated
soil excavation backfill near Lot 23. A second lift of fill was placed at the excavation backfill. Density testing and a proof
roll with a water truck indicated adequate compaction of the backfill.
A proof roll was also conducted on the lower fill lots (37-40). Approximately one foot of engineered fill soil was placed at
Lots 37-38, and Lots 39-40 were at subgrade elevation. The subgrade at Lots 37-40 was ripped, dried, and re-compacted
prior to placing engineered fill. The proof roll indicated moderate deflections at approximately Lots 39-40, and additional
drying activities were recommended for this area. Only slight deflections were observed at Lots 37-38 and this area was
approved for additional engineered fill. Based on my observations, engineered fill activities are proceeding in accordance
with project specifications.
DISTRIBUTION LIST: OBSERVED BY:
chris(a�thesaunderscompanv.net Eric Merritt
REVIEWED BY:
GeoPacific Engineering, Inc. Signature
Information contained herein pertains to materials tested/inspected only. The fact that any particular work has been observed or tested does not waive
the contractor's responsibility for the means and methods of construction,job site safety,or to comply with the contract documents. This information
contained herein should be considered preliminary until review by the project engineer.
GeoP cific
Engineering.Inc.
Real-World Geotechnical Solutions 14835 SW 72' Avenue Tel (503) 598-8445
Investigation •Design •Construction Support Portland, Oregon 97224 Fax(503) 941-9281
DENSITY TEST DATA SHEET
PROJECT SOIL DESCRIPTION DATE
Elderberry Ridge Onsite Native Silt Soils May 16,2018
PROJECT NUMBER WEATHER
15-4010 Partly cloudy,60s
CLIENT NUCLEAR GAUGE SERIAL# CONTRACTOR
Riverside Homes 34418 Saunders
PERMIT NUMBER METHOD OF TEST PAGE#
-- Troxler Gauge,T-99 1 of 1
FIELD FIELD DENSITY MAX.DRY COMP. COMP. OPTIMUM PASS
TEST
TYPE TEST LOCATION (FT) MOIST. (PCF) DENSITY SPEC. RESULT MOISTURE LAB ID OR
WET DRY (PCF) °/ % % FAIL
LF
-Lot 23, excavation backfill, north +4 18.1 123.4 104.5 108.4 95 96.4 17.6 P18-073 P
half
LF
-Lot 23,excavation backfill,south +4 18.2 124.2 105.1 108.4 95 97.0 17.6 P18-073 P
half
LF Lot 37, center +1 17.4 121.9 103.8 108.4 95 95.8 17.6 P18-073 P
LF Lot 38, center +1 19.1 125.3 105.2 108.4 95 97.0 17.6 P18-073 P
TEST TYPE: LF= Lot Fill SF=Structural Fill ST=Sanitary Trench DT=Storm Trench WT=Water Trench RF=Roadway Fill
RW=Retaining Wall Backfill PS= Pavement Subgrade BC=Base Course FT= Franchise Trench
REMARKS:
GeoPacific was onsite to conduct density testing of structural fill at the locations referenced above. The excavation
backfill at Lot 23 is approximately 10 feet deep, but this area receives a cut of 3 feet. Fill depths at Lots 35-40 is on the
order of 3-5 feet. Test results met project specifications for compaction at the locations tested.
TESTED BY: Eric Merritt REVIEWED BY:
Information contained herein pertains to materials tested/inspected only. The fact that any particular work has been observed or tested does not waive the
contractor's responsibility for the means and methods of construction,job site safety,or to comply with the contract documents. This information
contained herein should be considered preliminary until review by the project engineer.
GeoP cdic
Engineering,Inc.
Real-World Geotechnical Solutions 14835 SW 72nd Avenue Tel (503) 598-8445
Investigation • Design •Construction Support Portland, Oregon 97224 Fax(503) 941-9281
DENSITY TEST DATA SHEET
PROJECT SOIL DESCRIPTION DATE
Elderberry Ridge Onsite Native Silt Soils May 17,2018
PROJECT NUMBER WEATHER
15-4010 Overcast,60$
CLIENT NUCLEAR GAUGE SERIAL# CONTRACTOR
Riverside Homes 34418 Saunders
PERMIT NUMBER METHOD OF TEST PAGE#
-- Troxler Gauge,T-99 1 of 1
FIELD FIELD DENSITY MAX.DRY COMP. COMP. OPTIMUM PASS
TEST
TYPE TEST LOCATION �FT� MOIST. (PCF) DENSITY SPEC. RESULT MOISTURE LAB ID OR
WET DRY (PCF) % % % FAIL
LF -Lot 23, excavation backfill,center +6 16.4 124.8 107.2 108.4 95 98.9 17.6 P18-073 P
LF Lot 37, north center +3 17.5 122.0 103.8 108.4 95 95.8 17.6 P18-073 P
LF Lot 38, north center +3 17.0 122.6 104.8 108.4 95 96.7 17.6 P18-073 P
LF Lot 39, center +2 18.1 124.5 105.4 108.4 95 97.2 17.6 P18-073 P
LF Lot 40, center +2 18.2 125.5 106.2 108.4 95 98.0 17.6 P18-073 P
TEST TYPE: LF=Lot Fill SF=Structural Fill ST=Sanitary Trench DT=Storm Trench WT=Water Trench RF=Roadway Fill
RW=Retaining Wall Backfill PS=Pavement Subgrade BC=Base Course FT=Franchise Trench
REMARKS:
GeoPacific was onsite to conduct density testing of structural fill at the locations referenced above. The excavation
backfill at Lot 23 is approximately 10 feet deep, but this area receives a cut of 3 feet. Fill depths at Lots 35-40 is on the
order of 3-5 feet. Test results met project specifications for compaction at the locations tested.
TESTED BY: Eric Merritt REVIEWED BY: JDI
Information contained herein pertains to materials tested/inspected only. The fact that any particular work has been observed or tested does not waive the
contractor's responsibility for the means and methods of construction,job site safety,or to comply with the contract documents. This information
contained herein should be considered preliminary until review by the project engineer.
GeoPclflc
Engineering.Inc.
Real-World Geotechnical Solutions 14835 SW 72nd Avenue Tel (503) 598-8445
Investigation •Design •Construction Support Portland, Oregon 97224 Fax(503)941-9281
DENSITY TEST DATA SHEET
PROJECT SOIL DESCRIPTION DATE
Elderberry Ridge Onsite Native Silt Soils May 18,2018
PROJECT NUMBER WEATHER
15-4010 Overcast,60s
CLIENT NUCLEAR GAUGE SERIAL# CONTRACTOR
Riverside Homes 34418 Saunders
PERMIT NUMBER METHOD OF TEST PAGE#
-- Troxler Gauge,T-99 1 of 1
FIELD FIELD DENSITY MAX.DRY COMP. COMP. OPTIMUM PASS
TEST
TYPE TEST LOCATION (FT) MOIST. (PCF) DENSITY SPEC. RESULT MOISTURE LAB ID OR
WET DRY (PCF) % % % FAIL
LF -Lot 23, excavation backfill, center FG 16.8 122.9 105.2 108.4 95 97.0 17.6 P18-073 P
LF Lot 39, north center FG 17.4 122.9 104.7 108.4 95 96.6 17.6 P18-073 P
LF Lot 40, center FG 18.1 123.5 104.6 108.4 95 96.5 17.6 P18-073 P
TEST TYPE: LF= Lot Fill SF=Structural Fill ST=Sanitary Trench DT=Storm Trench WT=Water Trench RF= Roadway Fill
RW=Retaining Wall Backfill PS=Pavement Subgrade BC=Base Course FT= Franchise Trench
REMARKS:
GeoPacific was onsite to conduct density testing of structural fill at the locations referenced above. The excavation
backfill at Lot 23 is approximately 10 feet deep, but this area receives a cut of 3 feet. Fill depths at Lots 35-40 is on the
order of 3-5 feet. Test results met project specifications for compaction at the locations tested.
TESTED BY: Eric Merritt REVIEWED BY: JDI
Information contained herein pertains to materials tested/inspected only. The fact that any particular work has been observed or tested does not waive the
contractor's responsibility for the means and methods of construction,job site safety,or to comply with the contract documents. This information
contained herein should be considered preliminary until review by the project engineer.