Report (68)
Page Number of REZNOR® MODEL X (cont'd) INDOOR, GAS-FIRED, GRAVITY-VENTED DUCT FURNACE FOR COMMERCIAL/ INDUSTRIAL USE OPTIONAL FEATURES - • Single-stage thermostat FIELD INSTALLED • Two-stage thermostat • Electronic room override(makeup air applications only) • Thermostat guard with locking cover • Manual shut-off valve and union • Power venter with venter adapter • Condensate drain flange kit • Disconnect switch(UL Listed) TECHNICAL DATA 1 ModelX Size 75 100 125 ( 150 175 200 225 250 300 350 400 Input Heating BTUH 75,000 100,000 125,000 150,000 175,000 200,000 225,000 250,000 300,000 350,000 400,000 Capacity (kW) (22.0) (29.3) (36.6) (44.0) (51.3) (58.6) (65.9) (73.3) (87.9) (102.6) (117.2) Output Heating BTUH 60,000 80,000 100,000 ! 120,000 140,000 160,000 180,000 200,000 240,000 280,000 320,000 Capacity(80%)A (kW) (17.6) (23.4) (29.3) (35.2) (41.0) (46.9) (52.8) (58.6) (70.3) (82.1) (93.8) Full Load Amps(115V) 0.2 0.2 0.2 , 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 Unit Control Amps(24V) 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 Air Volume w/ cfm 610-1,105 815-1,475 1,020-1,840 1,225-2,210 1,430-2,580 1,635-2,945 1,840-3,315 2,045-3,685 2,455-4,420 2,865-5,160 3,275-5,895 Finger-Baffles (m3/hr) (1,036-1,877) (1,385-2,506) (1,733-3,126) (2,081-3,755) (2,429-4,383) (2,778-5,003) (3,126-5,632) (3,474-6,261) (4,171-7,509) (4,867-8,767) (5,564-10,015) Air Volume w/o cfm 735-2,765 980-3,685 1,225-4,605 1,475-5,530 1,720-6,450 1,965-7,370 2,210-8,295 2,455-9,215 2,945-11,060 3,440-12,900 3,930-14,745 Finger-Baffles B (m3/hr) (1,249-4,698) (1,665-6,261) (2,081-7,824), (2,506-9,395) (2,922-10,958) (3,338-12,521) (3,755-14,093) (4,171-15,656) (5,003-18,790) (5,844-21,916) (6,677-25,051) Net Weight lbs 150 150 163 182 186 224 231 276 286 320 355 (kg) (68) (68) (74) - (83) (84) (102) (105) (125) (130) (145) (161) Ship Weight lbs 170 170 200 220 230 275 290 350 360 390 420 (kg) (77) (77) (91) (100) (104) (125) (132) (159) (163) (177) (191) Gas Connection(in.) 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 3/4" 3/4" 3/4" Natural Flue Size 5"Rd. 6"Rd. 7"Ov. 8"Ov. ` 8"Ov. 8"Rd. 8"Rd. 10"Ov. 10"Ov. 12"Ov. 12"Ov. A In U.S.ratings are for altitudes to 2,000 feet.Above 2,000 feet derate by orifice change,4%for each 1,000 feet above sea level. In Canada ratings are for altitudes to 2,000 feet.For high altitude units(2,001-4,500 ft.)derate by 10%of maximum input. B For high air volume the finger-baffles in the heat exchanger section are removed during unit installation.See installation manual for instructions. c Sizes shown are for natural gas connections and are applicable to single stage gas valves,NOT supply line size.Propane gas connection is 1/2"for all sizes. Form RZ-C-DH Page 9 r " R EZNOR Page Number of MODEL X (cont'd) INDOOR, GAS-FIRED, GRAVITY-VENTED DUCT FURNACE FOR COMMERCIAL/ INDUSTRIAL USE DIMENSIONS ALTERNATE ±1/8ee(3mm) LOCATION P FOR FLUE COLLAR 2" 51mm } 1-5/8" 11-9/16" 12-9/16" 41mm 265mm _ryI t 319mm — < II t""1 3/4" — 1'l l 1 f1 2-3/4 I I r 19mm 70mm 'Y �`/`�./1� imJ I"Y,,,:•4 18" 19-1/2" 18" G ASR 457mm 495mm B 457mm I K K D E il I .w...:i THEGAS L NAE TFLOW y / / I I I A i r J _ I • ` 15/16" t 3/4" 8" ijt V 24mm 19mm 203mm 2-3/4" <-4"(102mm) I4 >I <--1 I< > 70mm 24-1/8" 15/16" A <-55/8"(143mm) 613mm EL ECR SUPPLY _ ' .4-6-3/4"(171mm) 26" 24mm 660mm TOP VIEW SIDE VIEW FRONT VIEW SIZE A B D E G H JK P Q 75 in. 19 1/4 32 1/4 12 1/2 14 30 1/4 2 9 5/8 13 3/4 3 1/2 20 3/4 (mm) (489) (819) (318) (356) (768) (51) (244) (349) (89) (527) 100 in. 191/4 321/4 121/2 14 301/4 2 95/8 133/4 31/2 203/4 (mm) (489) (819) (318) (356) (768) (51) (244) (349) (89) (527) 125 in. 22 321/4 151/4 163/4 301/4 2 11 161/2 31/2 203/4 (mm) (559) (819) (387) , (425) (768) (51) _12791 J4191 (89) (52Z 150,175 in. 27 1/2 32 1/4 20 3/4 22 1/4 30 1/4 2 13 3/4 22 3 1/2 20 3/4 (mm) (699) (819) (527) (565) (768) 51) (349) r (559) (89) (527) 200,225 in. 33 35 1/4 26 1/4 27 3/4 31 3/4 3 1/2 16 1/2 27 1/2 5 19 1/4 (mm) (838) (895) (667) (705) (806) (89) (419) (699) (127) (489) 250,300 in. 41 1/4 35 1/4 34 1/2 36 31 3/4 3 1/2 20 5/8 35 3/4 5 19 1/4 (mm) (1,048) (895) (876) (914) (806) (89) (524) (908) (127) (489) 350 in. 463/4 351/4 40 411/2 313/4 31/2 233/8 411/4 5 191/4 (mm) (1,187) (895) (1,016) (1,054) (806) (89) (594) (1,048) (127) (489) 400 in. 521/4 351/4 451/2 47 313/4 31/2 261/8 463/4 5 191/4 (mm) (1,327) (895) (1,156) (1,194) (806) (89) (664) (1,187) (127) (489) CLEARANCE FROM COMBUSTIBLES NOTES 1. Burner and control access shown left hand side.Specify right hand for opposite access 1. Top,flue connections,side opposite controls-6"(152mm) and connections(OptionAJ2). 2. Standard air flow as shown.Direction of air flow may be reversed by field relocation of air 2. Control side-unit width plus 6"(152mm) baffles. 3. See power venting arrangement section for more information. 3. Bottom-3"(76mm) Form RZ-C-DH Page 10