Specifications (37) RECEIVED NOV 13 2018 CROWN Date: September 07,2018 CITY OF TIGA D CASTLE Saleem Dooh ' tryr �de - Crown Castle ��I�-D Crown Castle 2000 Corporate Drive 2055 S. Stearman Drive Canonsburg, PA 15317 Chandler,AZ 85286 (724)416-2000 Subject: Structural Modification Report Carrier Designation: T-Mobile Co-Locate Carrier Site Number: P004037C Carrier Site Name: King City Crown Castle Designation: Crown Castle BU Number: 825028 Crown Castle Site Name: King City Crown Castle JDE Job Number: 517624 Crown Castle Work Order Number: 1613851 Crown Castle Order Number: 449094 Rev. 1 Engineering Firm Designation: Crown Castle Project Number: 1613851 Site Data: 13680 SW Pacific Highway, Tigard,Washington County, OR Latitude 45°25'14.2", Longitude-122°47'3.5" 99 Foot-Monopole Tower Dear Saleem Dooh, Crown Castle is pleased to submit this"Structural Modification Report" to determine the structural integrity of the above mentioned tower. This analysis has been performed in accordance with the Crown Castle Structural 'Statement of Work' and the terms of Crown Castle Purchase Order Number 1613851, in accordance with order 449094, revision 1. The purpose of the analysis is to determine acceptability of the tower stress level including the proposed modifications as outlined in the attached drawings, "Appendix D". Based on our analysis we have determined the tower stress level for the structure and foundation, under the following load case, to be: LC4: Modified Structure w/Existing + Reserved + Proposed Sufficient Capacity Note:See Table I and Table II for the proposed and existing/reserved loading,respectively. This analysis has been performed in accordance with the 2012 International Building Code and 2014 Oregon Structural Specialty Code(OSSC) based upon an ultimate 3-second gust wind speed of 120 mph converted to a nominal 3-second gust wind speed of 93 mph per section 1609.3.1 as required for use in the TIA-222-G Standard per Exception#5 of Section 1609.1.1. Exposure Category B and Risk Category II were used in this analysis. All modifications and equipment proposed in this report shall be installed in accordance with the attached drawings for the determined available structural capacity to be effective. We at Crown Castle appreciate the opportunity of providing our continuing professional services to you and Crown Castle. If you have any questions or need further assistance on this or any other projects please give us a call. Pfi Or- Structural analysis prepared by: Matthew Schmitt, E.I.T./DLT Respectfully submitted by: �`1 60529P E r Maged(Matthew)Abdel-Messih, P.E. Senior Project Engineer AEGON .;} tnxTower Report-version 8.0.2.1 �® Nsti� EXPIRES ,11.41_1,7A1 3 September 07, 2018 99 Ft Monopole Tower Structural Analysis CC/BU No 825028 Project Number 1613851, Order 449094, Revision 1 Page 2 TABLE OF CONTENTS 1) INTRODUCTION 2)ANALYSIS CRITERIA Table 1 -Proposed Antenna and Cable Information Table 2-Existing and Reserved Antenna and Cable Information Table 3-Design Antenna and Cable Information 3)ANALYSIS PROCEDURE Table 4-Documents Provided 3.1)Analysis Method 3.2)Assumptions 4)ANALYSIS RESULTS Table 5-Section Capacity(Summary) Table 6—Tower Component Stresses vs. Capacity 4.1) Recommendations 5)APPENDIX A tnxTower Output 6)APPENDIX B Base Level Drawing 7)APPENDIX C Additional Calculations 8)APPENDIX D Required Modification Drawings tnxTower Report-version 8.0.2.1 September 07, 2018 99 Ft Monopole Tower Structural Analysis CCI BU No 825028 Project Number 1613851, Order 449094, Revision 1 Page 3 1) INTRODUCTION This tower is a 99 ft Monopole tower designed by ENGINEERED ENDEAVORS, INC. in December of 2004 and mapped by FDH in August of 2016. The tower was originally designed for a wind speed of 80 mph per TIA/EIA- 222-F. The modification drawings designed by CCI and attached in Appendix D, have been considered in this analysis. 2)ANALYSIS CRITERIA The structural analysis was performed for this tower in accordance with the requirements of TIA-222-G Structural Standards for Steel Antenna Towers and Antenna Supporting Structures using a 3-second gust wind speed of 93 mph with no ice, 30 mph with 1 inch ice thickness and 60 mph under service loads, exposure category B. Table 1 -Proposed Antenna and Cable Information Center Number Number Feed Mounting Line Antenna Line Level (ft) Elevation of Manufacturer Antenna Model of Feed Size Note (ft) Antennas Lines in ( ) 3 ' andrew HBXX-6516DS-A2M w/ Mount Pipe 3 commscope FFHH-65C-R3 w/Mount Pipe 96.0 96.0 3 nokia ---- . AHFIB 1 1-3/5 3 nokia AHLOA 2 nokia FXFC 1 1 raycap _ I RNSNDC-7771-PF-48 1 site pro 1 �RMQP 3XX+ F3P HRK12 Table 2-Existing and Reserved Antenna and Cable Information Center Number Number Feed Mounting Line Antenna Antenna Model of Feed Line Note Level (ft) Elevation Antennas Manufacturer Size (ft) Lines (in) 6 commscope I ATM200-A20 96.0 96 0 3 �� SBNHH-1 D65B w/Mount 1 5/16 3 I I --T commscope Pie 12 7/8 6 93.0 P 3 I commscope E15S09P84 90.0 91.0 3 commscope E15S09P84 - - 3 I 88.0 I 3 I commscope I TMAT1921 XB68-21 A 3 commscope DHHTT65B-3XR 3 ericsson 800MHZ SMR FILTER 3 rfs celwave APXVSPP18-C-A20 3 samsung 1 OPTIC FIBER JUNCTION telecommunications; CYLINDER 80.0 � 80.0 �.. _. . . . .:. __�..,. .� samsung POWER JUNCTION 4 1-7/16 2 telecommunicationsI CYLINDER samsung I 3 ;telecommunications RRH-B8 3 samsung RRH C2C ;telecommunications tnxTower Report-version 8.0.2.1 September 07, 2018 99 Ft Monopole Tower Structural Analysis CC/BU No 825028 Project Number 1613851, Order 449094, Revision 1 Page 4 Center Number Number Feed Mounting Line Antenna Line Level (ft) Elevation of Manufacturer Antenna Model of Feed Size Note (ft) Antennas Lines (in) i , j 3 samsung RRH-P4 I telecommunications 1 ` tower mounts I Platform Mount[LP 301-1] 64.0 64.0 1tower mounts iSide Arm Mount[SO 302-3]I - I 1 _.. Notes: _... 1) Existing Equipment 2) Reserved Equipment 3) Equipment to be Removed;Not considered in this analysis Table 3-Design Antenna and Cable Information Center Number Number Feed Mounting Line Antenna Antenna Model of Feed Line Level (ft) Elevation Antennas Manufacturer (ft) Lines Size(in) I 96.0 3_ 96.0 3 EMS Wireless I DR65-19-02DPQ I 88.0 88.0 —I-3— EMS Wireless DR65-19-02DPQ - - j 80.0 80.0 T_._..3 —I—EMS Wireless DR65-19-02DPQ 772.0 j 72.0 ._-T-3 I EMS Wireless DR65-19-02DPQ I - r - 3)ANALYSIS PROCEDURE Table 4-Documents Provided Document Remarks Reference Source , I - ! . 4-GEOTECHNICAL REPORTS LSI Adapt Inc. 3472511 I CCISITES I .. 4-TOWER FOUNDATION Engineered Endeavors DRAWINGS/DESIGN/SPECS Incorporated 3485467 CCISITES 4-TOWER MANUFACTURERJFDH Engineering Inc. (Mapping)/1 6388772 I CCISITES DRAWINGS EEI 4-TOWER REINFORCEMENT Crown Castle 7—A;pendix D ON FILE DESIGN/DRAWINGS/DATA 3.1) Analysis Method tnxTower(version 8.0.2.1), a commercially available analysis software package, was used to create a three-dimensional model of the tower and calculate member stresses for various loading cases. Selected output from the analysis is included in Appendix A. 3.2) Assumptions '1) Tower and structures were built in accordance with the manufacturer's specifications. 2) The tower and structures have been maintained in accordance with the manufacturer's specification. 3) The configuration of antennas, transmission cables, mounts and other appurtenances are as specified in Tables 1 and 2 and the referenced drawings. This analysis may be affected if any assumptions are not valid or have been made in error. Crown Castle should be notified to determine the effect on the structural integrity of the tower. tnxTower Report-version 8.0.2.1 • September 07, 2018 99 Ft Monopole Tower Structural Analysis CCI BU No 825028 Project Number 1613851, Order 449094, Revision 1 Page 5 4)ANALYSIS RESULTS Table 5-Section Capacity(Summary) Section Elevation(ft) Component TypeCritical SF"P_allow % No. p Size Element P(K) (K) Capacity Pass I Fail L1 99-67 1 Pole TP26x26x0.375 1 i -10.14 950.95 29.5 Pass 1 L2 67-31.79 Pole TP30.75x25.5x0.1875 2 -12.76 912.69 83.5 Pass L3 31.79-0 Pole TP35x29.7787x0.25 3 -17.37 1485.15 80.3 P Pass Summary Pole(L2) 83.5 j Pass I 1 1 I Rating= 1 83.5 I Pass Table 6 -Tower Component Stresses vs. Capacity -LC4 Notes Component Elevation (ft) %Capacity Pass/Fail 1 i Flange Bolts 1 57.4 Pass 1 Flange Plates 67 32.1 Pass 1 Anchor Rods I 93.0 I Pass 1 Base Plate 0 41.6 Pass 1 Base Plate Stiffeners 47.4 Pass 1 Base Foundation Structure 37.6 Pass 1 Base Foundation Soil Interaction 0 I 39.1 I Pass Structure Rating(max from all components)= 93% Notes: 1) See additional documentation in"Appendix C—Additional Calculations"for calculations supporting the%capacity consumed. 4.1) Recommendations Perform the modifications detailed in"Appendix D"to remedy the deficiencies identified in Crown Castle Work Order No. 1605202. tnxTower Report-version 8.0.2.1 September 07, 2018 99 Ft Monopole Tower Structural Analysis CC/BU No 825028 Project Number 1613851, Order 449094, Revision 1 Page 6 APPENDIX A TNXTOWER OUTPUT tnxTower Report-version 8.0.2.1 99.0 ft I DESIGNED APPURTENANCE LOADING TYPE 1 ELEVATION 1 TYPE ELEVATION HBXX-6516DS-A2M w/Mount Pipe '96 APXVSPPI8-C-A20 80 HBXX-6516DS-A2M w/Mount Pipe 96 APXVSPP18-C-A20 80 HBXX-6516DS-A2M wl Mount Pipe 96 RRH-P4 80 FFHH-65C-R3 w/Mount Pipe 96 RRH-P4 80 FFHH-65C-R3 w/Mount Pipe 96 RRH-P4 80 c FFHH-65C-R3 w/Mount Pipe 96 RRH-B8 80 Pi $ 1 $ m AHLOA 96 RRH-88 80 of o H 8i lid H I AHLOA 96 RRH-B8 80 AHLOA 96 RRH-C2C 80 AHFIB 96 RRH-C2C 80 AHFIB 96 RRH-C2C m AHFIB 96 800MHZ SMR FILTER 80 (2)FXFC 96 800MHZ SMR FILTER 80 RNSNDC-7771-PF-48 96 800MHZ SMR FILTER 80 RMQP-3XX+F3P-HRK12 96 OPTIC FIBER JUNCTION CYUNDER 80 8'x Y Mount Pipe 96 OPTIC FIBER JUNCTION CYUNDER 80 8'x?Mount Pipe 96 OPTIC FIBER JUNCTION CYLINDER 80 8'x2'Mount Pipe 96 POWER JUNCTION CYLINDER 80 °'., , 67.0 ft DHHTT658-3XR 80 POWER JUNCTION CYLINDER 80 111 m DHHTT65B-3XR 80 POWER JUNCTION CYLINDER 80 DHHTT65B-3XR 80 Platform Mount[LP 301-1) 80 APXVSPPI8-C-A20 80 Side Nm Mount[SO 302-3) 64 MATERIAL STRENGTH GRADE Fy Fu GRADE Fy Fu A53-B-35 35 ksi 60 ksi A572-50 50 ksi 65 ksi TOWER DESIGN NOTES 1. Tower is located in Washington County,Oregon. 2. Tower designed for Exposure B to the TIA-222-G Standard. $II 3. Tower designed for a 93.00 mph basic wind in accordance with the TIA-222-G Standard. N 04. Tower is also designed for a 30.00 mph basic wind with 1.00 in ice.Ice is considered to v increase in thickness with height. 5. Deflections are based upon a 60.00 mph wind. 6. Tower Structure Class II. 7. Topographic Category 1 with Crest Height of 0.0000 ft 8. TOWER RATING:83.5% 0 7 N 31.8 ft ALL REACTIONS ARE FACTORED 8 AXIAL N 38 K g0 CO m O i- r M SHEAR MOMENT 11 j J 110 kip-ft TORQUE 0 kip-ft 30.00 mph WIND-1.0000 in ICE AXIAL 17K SHE11K MOMENT 11 K 840 kip-ft 0.0 ft m TORQUE 0 kip-ft s st REACTIONS-93.00 mph WIND M C g U W fpJ .� y y, O I 3 Z g .- !3 f Crown Castle lob:BU#825028 ,F✓ CROWN 2000 Corporate Drive Avid_ Canonsburg, PA 15317 Came Matthew Schmitt The Foundation for a Wireless World Phone:(724)416-2000 code_TIA-222-G Date'08/17/18 Sortie: NTS FAX: Path:P ...T.. B03 ,o,,386,�.. ...,.....,ROI NO.E-1 • September 07, 2018 99 Ft Monopole Tower Structural Analysis CCI BU No 825028 Project Number 1613851, Order 449094, Revision 1 Page 7 Tower Input Data The tower is a monopole. This tower is designed using the TIA-222-G standard. The following design criteria apply: 4) Tower is located in Washington County, Oregon. 5) Basic wind speed of 93.00 mph. 6) Structure Class II. 7) Exposure Category B. 8) Topographic Category 1. 9) Crest Height 0.0000 ft. 10) Nominal ice thickness of 1.0000 in. 11) Ice thickness is considered to increase with height. 12) Ice density of 56.00 pcf. 13) A wind speed of 30.00 mph is used in combination with ice. 14) Temperature drop of 50.00 °F. 15) Deflections calculated using a wind speed of 60.00 mph. 16) A non-linear(P-delta)analysis was used. 17) Pressures are calculated at each section. 18) Stress ratio used in pole design is 1. 19) Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not considered. Options Consider Moments-Legs Distribute Leg Loads As Uniform Use ASCE 10 X-Brace Ly Rules Consider Moments-Horizontals Assume Legs Pinned Calculate Redundant Bracing Forces Consider Moments-Diagonals J Assume Rigid Index Plate Ignore Redundant Members in FEA Use Moment Magnification J Use Clear Spans For Wind Area SR Leg Bolts Resist Compression J Use Code Stress Ratios Use Clear Spans For KL/r All Leg Panels Have Same Allowable J Use Code Safety Factors-Guys Retension Guys To Initial Tension Offset Girt At Foundation Escalate Ice J Bypass Mast Stability ChecksJ Consider Feed Line Torque Always Use Max Kz J Use Azimuth Dish Coefficients Include Angle Block Shear Check Use Special Wind Profile J Project Wind Area of Appurt. Use TIA-222-G Bracing Resist. Exemption Include Bolts In Member Capacity Autocalc Torque Arm Areas Use TIA-222-G Tension Splice Exemption Leg Bolts Are At Top Of Section Add IBC.6D+W Combination Poles Secondary Horizontal Braces Leg J Sort Capacity Reports By Component J Include Shear-Torsion Interaction Use Diamond Inner Bracing(4 Sided) Triangulate Diamond Inner Bracing Always Use Sub-Critical Flow SR Members Have Cut Ends Treat Feed Line Bundles As Cylinder Use Top Mounted Sockets SR Members Are Concentric Pole Without Linear Attachments Pole With Shroud Or No Appurtenances Outside and Inside Corner Radii Are Known Tapered Pole Section Geometry Section Elevation Section Splice V Number Top Bottom Wall Bend Pole Grade Length Length of Diameter Diameter Thickness Radius ft ft ft Sides in in in in L1 99.0000- 32.0000 0.00 Round 26.0000 26.0000 0.3750 A53-B-35 67.0000 (35 ksi) L2 67.0000- 35.2100 4.42 18 25.5000 30.7500 0.1875 0.7500 A572-50 31.7900 (50 ksi) L3 31.7900- 36.2100 18 29.7787 35.0000 0.2500 1.0000 A572-50 0.0000 (50 ksi) tnxTower Report-version 8.0.2.1 • ' September 07, 2018 99 Ft Monopole Tower Structural Analysis CCI BU No 825028 Project Number 1613851, Order 449094,Revision 1 Page 8 Tapered Pole Properties Section Tip Dia. Area I r C I/C J It/Q w w/t in in2 in4 in in in3 in' in2 in L1 26.0000 30.1887 2478.4250 9.0608 13.0000 190.6481 4956.8499 15.0854 0.0000 0 26.0000 30.1887 2478.4250 9.0608 13.0000 190.6481 4956.8499 15.0854 0.0000 0 L2 25.8645 15.0641 1219.4128 8.9859 12.9540 94.1341 2440.4302 7.5335 4.1580 22.176 31.1954 18.1885 2146.4080 10.8497 15.6210 137.4053 4295.6403 9.0960 5.0820 27.104 L3 30.8467 23.4310 2581.1800 10.4827 15.1276 170.6273 5165.7564 11.7177 4.8011 19.204 35.5014 27.5741 4206.7704 12.3363 17.7800 236.6013 8419.0762 13.7897 5.7200 22.88 Tower Gusset Gusset Gusset GradeAdjust.Factor Adjust. Weight Mult. Double Angle Double Angle Double Angle Elevation Area Thickness Al Factor Stitch Bolt Stitch Bolt Stitch Bolt (per face) Ar Spacing Spacing Spacing Diagonals Horizontals Redundants ft ft2 in in in in L1 99.0000- 1 1 1 67.0000 L2 67.0000- 1 1 1 31.7900 L331.7900- 1 1 1 0.0000 Feed Line/Linear Appurtenances - Entered As Round Or Flat Description Secto Component Placement Total Number Start/En Width or Perimete Weight r Type Number Per Row d Diamete r ft Position r pif in in Mr. TYPEI1(1-7/16) C Surface Ar 80.0000-0.0000 4 4 -0.500 1.4370 0.74 (CaAa) -0.300 Feed Line/Linear Appurtenances - Entered As Area Description Face Allow Component Placement Total CAAA Weight or Shield Type Number ***.• Leg ftft2/ft plf ASU9325TYP01(1-3/5) A No Inside Pole 96.0000-0.0000 1 No Ice 0.0000 1.61 112"Ice 0.0000 1.61 1"Ice 0.0000 1.61 *. ... • Feed Line/Linear Appurtenances Section Areas Tower Tower Face AR AF CAAA CAAA Weight Sectio Elevation In Face Out Face n ft ft2 ft2 ft2 ft2 K L1 99.0000-67.0000 A 0.000 0.000 0.000 0.000 0.05 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 7.472 0.000 0.04 L2 67.0000-31.7900 A 0.000 0.000 0.000 0.000 0.06 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 20.239 0.000 0.10 tnxTower Report-version 8.0.2.1 September 07, 2018 99 Ft Monopole Tower Structural Analysis CCl BU No 825028 Project Number 1613851, Order 449094, Revision 1 Page 9 Tower Tower Face AR AF CAAA CAAA Weight Sectio Elevation In Face Out Face n ft ft2 ft2 ft2 ft2 K L3 31.7900-0.0000 A 0.000 0.000 0.000 0.000 0.05 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 18.273 0.000 0.09 Feed Line/Linear Appurtenances Section Areas - With Ice Tower Tower Face Ice AR AF CAAA CAAA Weight Sectio Elevation or Thickness In Face Out Face n ft Leg in ft2 ft2 ft2 ft2 K L1 99.0000-67.0000 A 2.194 0.000 0.000 0.000 0.000 0.05 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 16.470 0.000 0.27 L2 67.0000-31.7900 A 2.082 0.000 0.000 0.000 0.000 0.06 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 43.624 0.000 0.68 L3 31.7900-0.0000 A 1.855 0.000 0.000 0.000 0.000 0.05 8 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 39.387 0.000 0.62 Feed Line Center of Pressure Section Elevation CPx CPz CPx CPz Ice Ice ft in in in in L1 99.0000-67.0000 1.5524 1.3978 1.3632 1.2274 L2 67.0000-31.7900 2.9780 2.6814 2.6130 2.3527 L3 31.7900-0.0000 3.0748 2.7686 2.7710 2.4950 Note:For pole sections,center of pressure calculations do not consider feed line shielding. Shielding Factor Ka Tower Feed Line Description Feed Line Ka Ka Section Record No. Segment No Ice Ice Elev. L1 6 TYPE 11(1-7/16) 67.00- 1.0000 1.0000 80.00 L2 6 TYPE II(1-7/16) 31.79- 1.0000 1.0000 67.00 Discrete Tower Loads tnxTower Report-version 8.0.2.1 • September 07, 2018 99 Ft Monopole Tower Structural Analysis CCI BU No 825028 Project Number 1613851, Order 449094, Revision 1 Page 10 Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustmen Front Side Leg Lateral t Vert ft ft ft2 ft2 K ft ° ft HBXX-6516DS-A2M w/ A From Leg 4.0000 0.0000 96.0000 No Ice 5.6558 4.5251 0.05 Mount Pipe 0.00 1/2" 6.0642 5.2049 0.10 0.00 Ice 6.4748 5.8567 0.15 1"Ice HBXX-6516DS-A2M w/ B From Leg 4.0000 0.0000 96.0000 No Ice 5.6558 4.5251 0.05 Mount Pipe 0.00 1/2" 6.0642 5.2049 0.10 0.00 Ice 6.4748 5.8567 0.15 1"Ice HBXX-6516DS-A2M w/ C From Leg 4.0000 0.0000 96.0000 No Ice 5.6558 4.5251 0.05 Mount Pipe 0.00 1/2" 6.0642 5.2049 0.10 0.00 Ice 6.4748 5.8567 0.15 1"Ice FFHH-65C-R3 w/Mount A From Leg 4.0000 0.0000 96.0000 No Ice 21.3753 11.5042 0.16 Pipe 0.00 1/2" 22.1324 13.0344 0.30 0.00 Ice 22.8984 14.5887 0.46 1"Ice FFHH-65C-R3 w/Mount B From Leg 4.0000 0.0000 96.0000 No Ice 21.3753 11.5042 0.16 Pipe 0.00 1/2" 22.1324 13.0344 0.30 0.00 Ice 22.8984 14.5887 0.46 1"Ice FFHH-65C-R3 w/Mount C From Leg 4.0000 0.0000 96.0000 No Ice 21.3753 11.5042 0.16 Pipe 0.00 1/2" 22.1324 13.0344 0.30 0.00 Ice 22.8984 14.5887 0.46 1"Ice AHLOA A From Leg 4.0000 0.0000 96.0000 No Ice 2.2289 1.3906 0.08 0.00 1/2" 2.4225 1.5518 0.10 0.00 Ice 2.6235 1.7200 0.12 1"Ice AHLOA B From Leg 4.0000 0.0000 96.0000 No Ice 2.2289 1.3906 0.08 0.00 1/2" 2.4225 1.5518 0.10 0.00 Ice 2.6235 1.7200 0.12 1"Ice AHLOA C From Leg 4.0000 0.0000 96.0000 No Ice 2.2289 1.3906 0.08 0.00 1/2" 2.4225 1.5518 0.10 0.00 Ice 2.6235 1.7200 0.12 1"Ice AHFIB A From Leg 4.0000 0.0000 96.0000 No Ice 3.6763 2.3086 0.09 0.00 1/2" 3.9250 2.5165 0.12 0.00 Ice 4.1810 2.7313 0.15 1"Ice AHFIB B From Leg 4.0000 0.0000 96.0000 No Ice 3.6763 2.3086 0.09 0.00 1/2" 3.9250 2.5165 0.12 0.00 Ice 4.1810 2.7313 0.15 1"Ice AHFIB C From Leg 4.0000 0.0000 96.0000 No Ice 3.6763 2.3086 0.09 0.00 1/2" 3.9250 2.5165 0.12 0.00 Ice 4.1810 2.7313 0.15 1"Ice (2)FXFC A From Leg 4.0000 0.0000 96.0000 No Ice 0.8407 0.9577 0.06 0.00 1/2" 0.9810 1.1130 0.08 0.00 Ice 1.1288 1.2758 0.10 1"Ice RNSNDC-7771-PF-48 B From Leg 4.0000 0.0000 96.0000 No Ice 2.7309 1.0266 0.01 0.00 1/2" 2.9372 1.1707 0.03 0.00 Ice 3.1508 1.3217 0.06 1"Ice RMQP-3XX+F3P-HRK12 C None 0.0000 96.0000 No Ice 27.9800 26.5000 1.68 1/2" 32.8600 31.6000 1.99 Ice 38.0900 36.8100 2.38 1"Ice 8'x 2"Mount Pipe A From Leg 4.0000 0.0000 96.0000 No Ice 1.9000 1.9000 0.03 0.00 1/2" 2.7281 2.7281 0.04 0.00 Ice 3.4009 3.4009 0.06 1"Ice tnxTower Report-version 8.0.2.1 • ` September 07, 2018 99 Ft Monopole Tower Structural Analysis CCI BU No 825028 Project Number 1613851, Order 449094, Revision 1 Page 11 Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustmen Front Side Leg Lateral t Vert ft ft ft2 ft2 K ft ° ft 8'x 2"Mount Pipe B From Leg 4.0000 0.0000 96.0000 No Ice 1.9000 1.9000 0.03 0.00 1/2" 2.7281 2.7281 0.04 0.00 Ice 3.4009 3.4009 0.06 1"Ice 8'x 2"Mount Pipe C From Leg 4.0000 0.0000 96.0000 No Ice 1.9000 1.9000 0.03 0.00 1/2" 2.7281 2.7281 0.04 0.00 Ice 3.4009 3.4009 0.06 1"Ice DHHTT65B-3XR A From Leg 4.0000 0.0000 80.0000 No Ice 8.1333 5.3417 0.05 0.00 1/2" 8.5899 5.7948 0.10 0.00 Ice 9.0535 6.2554 0.16 1"Ice DHHTT65B-3XR B From Leg 4.0000 0.0000 80.0000 No Ice 8.1333 5.3417 0.05 0.00 1/2" 8.5899 5.7948 0.10 0.00 Ice 9.0535 6.2554 0.16 1"Ice DHHTT65B-3XR C From Leg 4.0000 0.0000 80.0000 No Ice 8.1333 5.3417 0.05 0.00 1/2" 8.5899 5.7948 0.10 0.00 Ice 9.0535 6.2554 0.16 1"Ice APXVSPP18-C-A20 A From Leg 4.0000 0.0000 80.0000 No Ice 8.0244 5.2833 0.06 0.00 1/2" 8.4800 5.7360 0.11 0.00 Ice 8.9426 6.1960 0.16 1"Ice APXVSPP18-C-A20 B From Leg 4.0000 0.0000 80.0000 No Ice 8.0244 5.2833 0.06 0.00 1/2" 8.4800 5.7360 0.11 0.00 Ice 8.9426 6.1960 0.16 1"Ice APXVSPP18-C-A20 C From Leg 4.0000 0.0000 80.0000 No Ice 8.0244 5.2833 0.06 0.00 1/2" 8.4800 5.7360 0.11 0.00 Ice 8.9426 6.1960 0.16 1"Ice RRH-P4 A From Leg 4.0000 0.0000 80.0000 No Ice 2.7353 1.7890 0.06 0.00 1/2" 2.9479 1.9675 0.08 0.00 Ice 3.1679 2.1576 0.11 1"Ice RRH-P4 B From Leg 4.0000 0.0000 80.0000 No Ice 2.7353 1.7890 0.06 0.00 1/2" 2.9479 1.9675 0.08 0.00 Ice 3.1679 2.1576 0.11 1"Ice RRH-P4 C From Leg 4.0000 0.0000 80.0000 No Ice 2.7353 1.7890 0.06 0.00 1/2" 2.9479 1.9675 0.08 0.00 Ice 3.1679 2.1576 0.11 1"Ice RRH-B8 A From Leg 4.0000 0.0000 80.0000 No Ice 2.8802 1.7425 0.06 0.00 1/2" 3.0951 1.9226 0.08 0.00 Ice 3.3174 2.1119 0.11 1"Ice RRH-B8 B From Leg 4.0000 0.0000 80.0000 No Ice 2.8802 1.7425 0.06 0.00 1/2" 3.0951 1.9226 0.08 0.00 Ice 3.3174 2.1119 0.11 1"Ice RRH-B8 C From Leg 4.0000 0.0000 80.0000 No Ice 2.8802 1.7425 0.06 0.00 1/2" 3.0951 1.9226 0.08 0.00 Ice 3.3174 2.1119 0.11 1"Ice RRH-C2C A From Leg 4.0000 0.0000 80.0000 No Ice 1.0972 2.5251 0.05 0.00 1/2" 1.2398 2.7232 0.07 0.00 Ice 1.3895 2.9288 0.09 1"Ice RRH-C2C B From Leg 4.0000 0.0000 80.0000 No Ice 1.0972 2.5251 0.05 0.00 1/2" 1.2398 2.7232 0.07 0.00 Ice 1.3895 2.9288 0.09 tnxTower Report-version 8.0.2.1 September 07, 2018 99 Ft Monopole Tower Structural Analysis CCI BU No 825028 Project Number 1613851, Order 449094, Revision 1 Page 12 Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustmen Front Side Leg Lateral Vert ft ft ft2 re ft ° ft • 1"Ice RRH-C2C C From Leg 4.0000 0.0000 80.0000 No Ice 1.0972 2.5251 0.05 0.00 1/2" 1.2398 2.7232 0.07 0.00 Ice 1.3895 2.9288 0.09 1"Ice 800MHZ SMR FILTER A From Leg 4.0000 0.0000 80.0000 No Ice 0.6497 0.2218 0.01 0.00 1/2" 0.7516 0.2883 0.01 0.00 Ice 0.8608 0.3638 0.02 1"Ice 800MHZ SMR FILTER B From Leg 4.0000 0.0000 80.0000 No Ice 0.6497 0.2218 0.01 0.00 1/2" 0.7516 0.2883 0.01 0.00 Ice 0.8608 0.3638 0.02 1"Ice 800MHZ SMR FILTER C From Leg 4.0000 0.0000 80.0000 No Ice 0.6497 0.2218 0.01 0.00 1/2" 0.7516 0.2883 0.01 0.00 Ice 0.8608 0.3638 0.02 1"Ice OPTIC FIBER JUNCTION A From Leg 4.0000 0.0000 80.0000 No Ice 0.3888 0.3888 0.00 CYLINDER 0.00 1/2" 0.4753 0.4753 0.01 0.00 Ice 0.5704 0.5704 0.01 1"Ice OPTIC FIBER JUNCTION B From Leg 4.0000 0.0000 80.0000 No Ice 0.3888 0.3888 0.00 CYLINDER 0.00 1/2" 0.4753 0.4753 0.01 0.00 Ice 0.5704 0.5704 0.01 1"Ice OPTIC FIBER JUNCTION C From Leg 4.0000 0.0000 80.0000 No Ice 0.3888 0.3888 0.00 CYLINDER 0.00 1/2" 0.4753 0.4753 0.01 0.00 Ice 0.5704 0.5704 0.01 1"Ice POWER JUNCTION A From Leg 4.0000 0.0000 80.0000 No Ice 0.3691 0.3691 0.00 CYLINDER 0.00 1/2" 0.4528 0.4528 0.01 0.00 Ice 0.5470 0.5470 0.01 1"Ice POWER JUNCTION B From Leg 4.0000 0.0000 80.0000 No Ice 0.3691 0.3691 0.00 CYLINDER 0.00 1/2" 0.4528 0.4528 0.01 0.00 Ice 0.5470 0.5470 0.01 1"Ice POWER JUNCTION C From Leg 4.0000 0.0000 80.0000 No Ice 0.3691 0.3691 0.00 CYLINDER 0.00 1/2" 0.4528 0.4528 0.01 0.00 Ice 0.5470 0.5470 0.01 1"Ice Platform Mount[LP 301-1) C None 0.0000 80.0000 No Ice 30.1000 30.1000 1.59 1/2" 40.8000 40.8000 2.03 Ice 51.5000 51.5000 2.47 1"Ice Side Arm Mount[SO 302- C None 0.0000 64.0000 No Ice 5.5600 5.5600 0.17 3] 1/2" 8.4400 8.4400 0.26 Ice 11.3200 11.3200 0.36 1"Ice Load Combinations Comb. . „. Description No. tnxTower Report-version 8.0.2.1 September 07, 2018 99 Ft Monopole Tower Structural Analysis CC/BU No 825028 Project Number 1613851, Order 449094, Revision 1 Page 13 Comb. Description No. 1 Dead Only 2 1.2 Dead+1.6 Wind O deg-No Ice 3 0.9 Dead+1.6 Wind 0 deg-No Ice 4 1.2 Dead+1.6 Wind 30 deg-No Ice 5 0.9 Dead+1.6 Wind 30 deg-No Ice 6 1.2 Dead+1.6 Wind 60 deg-No Ice 7 0.9 Dead+1.6 Wind 60 deg-No Ice 8 1.2 Dead+1.6 Wind 90 deg-No Ice 9 0.9 Dead+1.6 Wind 90 deg-No Ice 10 1.2 Dead+1.6 Wind 120 deg-No Ice 11 0.9 Dead+1.6 Wind 120 deg-No Ice 12 1.2 Dead+1.6 Wind 150 deg-No Ice 13 0.9 Dead+1.6 Wind 150 deg-No Ice 14 1.2 Dead+1.6 Wind 180 deg-No Ice 15 0.9 Dead+1.6 Wind 180 deg-No Ice 16 1.2 Dead+1.6 Wind 210 deg-No Ice 17 0.9 Dead+1.6 Wind 210 deg-No Ice 18 1.2 Dead+1.6 Wind 240 deg-No Ice 19 0.9 Dead+1.6 Wind 240 deg-No Ice 20 1.2 Dead+1.6 Wind 270 deg-No Ice 21 0.9 Dead+1.6 Wind 270 deg-No Ice 22 1.2 Dead+1.6 Wind 300 deg-No Ice 23 0.9 Dead+1.6 Wind 300 deg-No Ice 24 1.2 Dead+1.6 Wind 330 deg-No Ice 25 0.9 Dead+1.6 Wind 330 deg-No Ice 26 1.2 Dead+1.0 Ice+1.0 Temp 27 1.2 Dead+1.0 Wind 0 deg+1.0 Ice+1.0 Temp 28 1.2 Dead+1.0 Wind 30 deg+1.0 Ice+1.0 Temp 29 1.2 Dead+1.0 Wind 60 deg+1.0 Ice+1.0 Temp 30 1.2 Dead+1.0 Wind 90 deg+1.0 Ice+1.0 Temp 31 1.2 Dead+1.0 Wind 120 deg+1.0 Ice+1.0 Temp 32 1.2 Dead+1.0 Wind 150 deg+1.0 Ice+1.0 Temp 33 1.2 Dead+1.0 Wind 180 deg+1.0 Ice+1.0 Temp 34 1.2 Dead+1.0 Wind 210 deg+1.0 Ice+1.0 Temp 35 1.2 Dead+1.0 Wind 240 deg+1.0 Ice+1.0 Temp 36 1.2 Dead+1.0 Wind 270 deg+1.0 Ice+1.0 Temp 37 1.2 Dead+1.0 Wind 300 deg+1.0 Ice+1.0 Temp 38 1.2 Dead+1.0 Wind 330 deg+1.0 Ice+1.0 Temp 39 Dead+Wind 0 deg-Service 40 Dead+Wind 30 deg-Service 41 Dead+Wind 60 deg-Service 42 Dead+Wind 90 deg-Service 43 Dead+Wind 120 deg-Service 44 Dead+Wind 150 deg-Service 45 Dead+Wind 180 deg-Service 46 Dead+Wind 210 deg-Service 47 Dead+Wind 240 deg-Service 48 Dead+Wind 270 deg-Service 49 Dead+Wind 300 deg-Service 50 Dead+Wind 330 deg-Service Maximum Member Forces Sectio Elevation Component Condition Gov. Axial Major Axis Minor Axis n ft Type Load Moment Moment No. Comb. K kip-ft kip-ft L1 99-67 Pole Max Tension 9 0.00 0.00 -0.00 Max.Compression 26 -24.47 -0.92 1.57 Max.Mx 8 -10.14 -176.55 0.02 Max.My 2 -10.15 0.57 176.18 Max.Vy 8 8.44 -176.55 0.02 Max.Vx 2 -8.41 0.57 176.18 Max.Torque 10 0.26 L2 67-31.79 Pole Max Tension 1 0.00 0.00 0.00 Max.Compression 26 -30.23 -1.62 1.14 Max.Mx 8 -12.76 -460.36 -0.75 Max.My 2 -12.77 1.16 458.77 tnxTower Report-version 8.0.2.1 September 07, 2018 99 Ft Monopole Tower Structural Analysis CC/BU No 825028 Project Number 1613851, Order 449094, Revision 1 Page 14 Sectio Elevation Component Condition Gov. Axial Major Axis Minor Axis n ft Type Load Moment Moment No. Comb. K kip-ft kip-ft Max.Vy 8 9.81 -460.36 -0.75 Max.Vx 2 -9.78 1.16 458.77 Max.Torque 10 0.26 L3 31.79-0 Pole Max Tension 1 0.00 0.00 0.00 Max.Compression 26 -38.33 -2.38 0.47 Max.Mx 8 -17.37 -839.20 -1.66 Max.My 2 -17.37 1.82 836.18 Max.Vy 8 11.08 -839.20 -1.66 Max.Vx 2 -11.05 1.82 836.18 Max.Torque 10 0.26 Maximum Reactions Location Condition Gov. Vertical Horizontal,X Horizontal,Z Load K K K Comb. Pole Max.Vert 30 38.33 -1.36 -0.00 Max.Hx 20 17.38 11.06 0.02 Max.HZ 3 13.04 0.02 11.03 Max.Mx 2 836.18 0.02 11.03 Max.Mz 8 839.20 -11.06 -0.02 Max.Torsion 10 0.26 -9.59 -5.53 Min.Vert 17 13.04 5.51 -9.54 Min.Hx 9 13.04 -11.06 -0.02 Min.Hi 15 13.04 -0.02 -11.03 Min.Mx 14 -835.17 -0.02 -11.03 Min.Mz 20 -838.51 11.06 0.02 Min.Torsion 22 -0.26 9.59 5.53 Tower Mast Reaction Summary Load Vertical Shear„ Shear Overturning Overturning Torque Combination Moment,MX Moment,MZ K K K kip-ft kip-ft kip-ft Dead Only 14.48 0.00 0.00 -0.38 -0.27 0.00 1.2 Dead+1.6 Wind 0 deg- 17.38 -0.02 -11.03 -836.18 1.82 0.13 No Ice 0.9 Dead+1.6 Wind 0 deg- 13.04 -0.02 -11.03 -825.48 1.88 0.13 No Ice 1.2 Dead+1.6 Wind 30 deg- 17.38 5.51 -9.54 -723.14 -417.90 0.00 No Ice 0.9 Dead+1.6 Wind 30 deg- 13.04 5.51 -9.54 -713.88 -412.54 0.00 No Ice 1.2 Dead+1.6 Wind 60 deg- 17.38 9.57 -5.50 -416.47 -725.74 -0.13 No Ice 0.9 Dead+1.6 Wind 60 deg- 13.04 9.57 -5.50 -411.08 -716.48 -0.12 No Ice 1.2 Dead+1.6 Wind 90 deg- 17.38 11.06 0.02 1.66 -839.20 -0.22 No Ice 0.9 Dead+1.6 Wind 90 deg- 13.04 11.06 0.02 1.77 -828.50 -0.22 No Ice 1.2 Dead+1.6 Wind 120 deg 17.38 9.59 5.53 419.20 -727.89 -0.26 -No Ice 0.9 Dead+1.6 Wind 120 deg 13.04 9.59 5.53 414.03 -718.60 -0.25 -No Ice 1.2 Dead+1.6 Wind 150 deg 17.38 5.55 9.56 724.29 -421.65 -0.22 -No Ice 0.9 Dead+1.6 Wind 150 deg 13.04 5.55 9.56 715.27 -416.23 -0.22 -No Ice 1.2 Dead+1.6 Wind 180 deg 17.38 0.02 11.03 835.17 -2.51 -0.13 -No Ice tnxTower Report-version 8.0.2.1 ' September 07, 2018 99 Ft Monopole Tower Structural Analysis CCI BU No 825028 Project Number 1613851, Order 449094, Revision 1 Page 15 Load Vertical Shear x Shear ZOverturning Overturning Torque Combination Moment,MX Moment ,M: K K K kip-ft kip-ft kip-ft 0.9 Dead+1.6 Wind 180 deg 13.04 0.02 11.03 824.75 -No Ice 2.39 -0.13 1.2 Dead+1.6 Wind 210 deg 17.38 -5.51 9.54 722.13 417.22 -0.00 -No Ice 0.9 Dead+1.6 Wind 210 deg 13.04 -5.51 9.54 713.14 412.03 -0.00 -No Ice 1.2 Dead+1.6 Wind 240 deg 17.38 -9.57 5.50 415.46 725.05 0.13 -No Ice 0.9 Dead+1.6 Wind 240 deg 13.04 -9.57 5.50 410.34 715.97 0.12 -No Ice 1.2 Dead+1.6 Wind 270 deg 17.38 -11.06 -0.02 -2.67 838.51 0.22 -No Ice 0.9 Dead+1.6 Wind 270 deg 13.04 -11.06 -0.02 -2.50 828.00 0.22 -No Ice 1.2 Dead+1.6 Wind 300 deg 17.38 -9.59 -5.53 -420.21 727.21 0.26 -No Ice 0.9 Dead+1.6 Wind 300 deg 13.04 -9.59 -5.53 -414.77 718.10 0.25 -No Ice 1.2 Dead+1.6 Wind 330 deg 17.38 -5.55 -9.56 -725.30 420.96 0.22 -No Ice 0.9 Dead+1.6 Wind 330 deg 13.04 -5.55 -9.56 -716.00 415.72 0.22 -No Ice 1.2 Dead+1.0 Ice+1.0 Temp 38.33 0.00 -0.00 -0.47 2.380.00 1.2 Dead+1.0 Wind 0 38.33 -0.00 -1.36 -107.57 -2.26 0.02 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 30 38.33 0.68 -1.18 -93.14 -55.97 0.00 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 60 38.33 1.18 -0.68 -53.88 -95.33 -0.02 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 90 38.33 1.36 0.00 -0.31 -109.81 -0.03 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 120 38.33 1.18 0.68 53.2195.51 -0.03 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 150 38.33 0.68 1.18 92.34 -56.28 -0.03 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 180 38.33 0.00 1.36 106.602.62 -0.02 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 210 38.33 -0.68 1.18 92.17 51.09 0.00 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 240 38.33 -1.18 0.68 52,90 90.46 0.02 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 270 38.33 -1.36 -0.00 -0.66 104.93 0.03 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 300 38.33 -1.18 -0.68 54.18 90.64 0.03 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 330 38.33 -0.68 -1.18 93.3251.40 0.03 deg+1.0 Ice+1.0 Temp Dead+Wind 0 deg-Service 14.48 -0.00 -2.57 -193.45 0.22 0.03 Dead+Wind 30 deg-Service 14.48 1.28 -2.22 -167.34 -96.74 0.00 Dead+Wind 60 deg-Service 14.48 2.23 -1.28 -96.50 -167.84 -0.03 Dead+Wind 90 deg-Service 14.48 2.57 0.00 0.08 -194.05 -0.05 Dead+Wind 120 deg- 14.48 2.23 1.29 96.54 -168.34 0.06 Service Dead+Wind 150 deg- 14.48 1.29 2.23 167.01 -97.60 -0.05 Service Dead+Wind 180 deg- 14.48 0.00 2.57 192.62 -0.78 -0.03 Service Dead+Wind 210 deg- 14.48 -1.28 2.22 166.51 96.17 -0.00 Service Dead+Wind 240 deg- 14.48 -2.23 1.28 95.67 167.28 0.03 Service Dead+Wind 270 deg- 14.48 -2.57 -0.00 -0.91 193.49 0.05 Service Dead+Wind 300 deg- 14.48 -2.23 -1.29 -97.36 167.78 0.06 Service Dead+Wind 330 deg- 14.48 -1.29 -2.23 -167.84 97.03 0.05 Service tnxTower Report-version 8.0.2.1 ' September 07, 2018 99 Ft Monopole Tower Structural Analysis CCI BU No 825028 Project Number 1613851, Order 449094, Revision 1 Page 16 Solution Summary Sum of Applied Forces Sum of Reactions Load PX PY PZ PX PY PZ %Error Comb. K K K K K K 1 0.00 -14.48 0.00 0.00 14.48 0.00 0.000% 2 -0.02 -17.38 -11.03 0.02 17.38 11.03 0.000% 3 -0.02 -13.04 -11.03 0.02 13.04 11.03 0.000% 4 5.51 -17.38 -9.54 -5.51 17.38 9.54 0.000% 5 5.51 -13.04 -9.54 -5.51 13.04 9.54 0.000% 6 9.57 -17.38 -5.50 -9.57 17.38 5.50 0.000% 7 9.57 -13.04 -5.50 -9.57 13.04 5.50 0.000% 8 11.06 -17.38 0.02 -11.06 17.38 -0.02 0.000% 9 11.06 -13.04 0.02 -11.06 13.04 -0.02 0.000% 10 9.59 -17.38 5.53 -9,59 17.38 -5.53 0.000% 11 9.59 -13.04 5.53 -9.59 13.04 -5.53 0.000% 12 5.55 -17.38 9.56 -5.55 17.38 -9.56 0.000% 13 5.55 -13.04 9.56 -5.55 13.04 -9.56 0.000% 14 0.02 -17.38 11.03 -0.02 17.38 -11.03 0.000% 15 0.02 -13.04 11.03 -0.02 13.04 -11.03 0.000% 16 -5.51 -17.38 9.54 5.51 17.38 -9.54 0.000% 17 -5.51 -13.04 9.54 5.51 13.04 -9.54 0.000% 18 -9.57 -17.38 5.50 9.57 17.38 -5.50 0.000% 19 -9.57 -13.04 5.50 9.57 13.04 -5.50 0.000% 20 -11.06 -17.38 -0.02 11.06 17.38 0.02 0.000% 21 -11.06 -13.04 -0.02 11.06 13.04 0.02 0.000% 22 -9.59 -17.38 -5.53 9.59 17.38 5.53 0.000% 23 -9.59 -13.04 -5.53 9.59 13.04 5.53 0.000% 24 -5.55 -17.38 -9.56 5.55 17.38 9.56 0.000% 25 -5.55 -13.04 -9.56 5.55 13.04 9.56 0.000% 26 0.00 -38.33 0.00 -0.00 38.33 0.00 0.000% 27 -0.00 -38.33 -1.36 0.00 38.33 1.36 0.000% 28 0.68 -38.33 -1.18 -0.68 38.33 1.18 0.000% 29 1.18 -38.33 -0.68 -1.18 38.33 0.68 0.000% 30 1.36 -38.33 0.00 -1.36 38.33 -0.00 0.000% 31 1.18 -38.33 0.68 -1.18 38.33 -0.68 0.000% 32 0.68 -38.33 1.18 -0.68 38.33 -1.18 0.000% 33 0.00 -38.33 1.36 -0.00 38.33 -1.36 0.000% 34 -0.68 -38.33 1.18 0.68 38.33 -1.18 0.000% 35 -1.18 -38.33 0.68 1.18 38.33 -0.68 0.000% 36 -1.36 -38.33 -0.00 1.36 38.33 0.00 0.000% 37 -1.18 -38.33 -0.68 1.18 38.33 0.68 0.000% 38 -0.68 -38.33 -1.18 0.68 38.33 1.18 0.000% 39 -0.00 -14.48 -2.57 0.00 14.48 2.57 0.000% 40 1.28 -14.48 -2.22 -1.28 14.48 2.22 0.000% 41 2.23 -14.48 -1.28 -2.23 14.48 1.28 0.000% 42 2.57 -14.48 0.00 -2.57 14.48 -0.00 0.000% 43 2.23 -14.48 1.29 -2.23 14.48 -1.29 0.000% 44 1.29 -14.48 2.23 -1.29 14.48 -2.23 0.000% 45 0.00 -14.48 2.57 -0.00 14.48 -2.57 0.000% 46 -1.28 -14.48 2.22 1.28 14.48 -2.22 0.000% 47 -2.23 -14.48 1.28 2.23 14.48 -1.28 0.000% 48 -2.57 -14.48 -0.00 2.57 14.48 0.00 0.000% 49 -2.23 -14.48 -1.29 2.23 14.48 1.29 0.000% 50 -1.29 -14.48 -2.23 1.29 14.48 2.23 0.000% Non-Linear Convergence Results Load Converged? Number Displacement Force Combination of Cycles Tolerance Tolerance 1 Yes 4 0.00000001 0.00000001 2 Yes 5 0.00000001 0.00003039 3 Yes 4 0.00000001 0.00048219 4 Yes 6 0.00000001 0.00014407 5 Yes 6 0.00000001 0.00004991 tnxTower Report-version 8.0.2.1 September 07, 2018 99 Ft Monopole Tower Structural Analysis CCI BU No 825028 Project Number 1613851, Order 449094, Revision 1 Page 17 6 Yes 6 0.00000001 0.00014553 7 Yes 6 0.00000001 0.00005042 8 Yes 5 0.00000001 0.00006169 9 Yes 4 0.00000001 0.00074045 10 Yes 6 0.00000001 0.00014288 11 Yes 6 0.00000001 0.00004943 12 Yes 6 0.00000001 0.00014759 13 Yes 6 0.00000001 0.00005120 14 Yes 5 0.00000001 0.00006192 15 Yes 4 0.00000001 0.00075206 16 Yes 6 0.00000001 0.00014281 17 Yes 6 0.00000001 0.00004958 18 Yes 6 0.00000001 0.00014182 19 Yes 6 0.00000001 0.00004920 20 Yes 5 0.00000001 0.00009439 21 Yes 5 0.00000001 0.00004483 22 Yes 6 0.00000001 0.00014883 23 Yes 6 0.00000001 0.00005156 24 Yes 6 0.00000001 0.00014364 25 Yes 6 0.00000001 0.00004965 26 Yes 4 0.00000001 0.00009729 27 Yes 5 0.00000001 0.00040158 28 Yes 5 0.00000001 0.00043696 29 Yes 5 0.00000001 0.00043840 30 Yes 5 0.00000001 0.00040558 31 Yes 5 0.00000001 0.00042707 32 Yes 5 0.00000001 0.00042297 33 Yes 5 0.00000001 0.00038563 34 Yes 5 0.00000001 0.00040463 35 Yes 5 0.00000001 0.00040428 36 Yes 5 0.00000001 0.00038388 37 Yes 5 0.00000001 0.00041895 38 Yes 5 0.00000001 0.00042200 39 Yes 4 0.00000001 0.00006931 40 Yes 4 0.00000001 0.00056651 41 Yes 4 0.00000001 0.00058539 42 Yes 4 0.00000001 0.00008887 43 Yes 4 0.00000001 0.00052973 44 Yes 4 0.00000001 0.00059611 45 Yes 4 0.00000001 0.00007245 46 Yes 4 0.00000001 0.00054706 47 Yes 4 0.00000001 0.00053204 48 Yes 4 0.00000001 0.00009400 49 Yes 4 0.00000001 0.00061308 50 Yes 4 0.00000001 0.00054260 Maximum Tower Deflections - Service Wind Section Elevation Horz. Gov. Tilt Twist No. Deflection Load ft in Comb. ° L1 99-67 11.735 50 0.8858 0.0009 L2 67-31.79 5.909 49 0.8275 0.0006 L3 36.21 -0 1.753 42 0.4338 0.0002 Critical Deflections and Radius of Curvature - Service Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature ft Comb. in ° ft 96.0000 HBXX-6516DS-A2M vv/Mount 50 11.167 0.8893 0.0009 55758 Pipe 80.0000 DHHTT65B-3XR 50 8.185 0.8882 0.0008 14673 64.0000 Side Arm Mount[SO 302-3 49 5.413 0.8015 0.0006 7540 tnxTower Report-version 8.0.2.1 • September 07, 2018 99 Ft Monopole Tower Structural Analysis CCI BU No 825028 Project Number 1613851, Order 449094, Revision 1 Page 18 Maximum Tower Deflections - Design Wind Section Elevation Horz. Gov. Tilt Twist No. Deflection Load ft in Comb. ° L1 99-67 50.813 22 3.8351 0.0038 L2 67-31.79 25.602 22 3.5868 0.0028 L3 36.21 -0 7.596 22 1.8805 0.0010 Critical Deflections and Radius of Curvature - Design Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature ft Comb. in ft 96.0000 HBXX-6516DS-A2M w/Mount 22 48.356 3.8508 0.0037 13070 Pipe 80.0000 DHHTT65B-3XR 22 35.456 3.8487 0.0033 3438 64.0000 Side Arm Mount[SO 302-1 22 23.456 3.4745 0.0026 1761 Compression Checks Pole Design Data Section Elevation Size L L KI/r A P„ gyp„ Ratio No. Pu ft ft ft int K K (I)Pn L1 99-67(1) TP26x26x0.375 32.000 0.0000 0.0 30.188 -10.14 950.95 0.011 0 7 L2 67-31.79(2) TP30.75x25.5x0.1875 35.210 0.0000 0.0 17.796 -12.76 912.69 0.014 0 3 L3 31.79-0(3) TP35x29.7787x0.25 36.210 0.0000 0.0 27.574 -17.37 1485.15 0.012 0 1 Pole Bending Design Data Section Elevation Size Mux (I)Mnx Ratio Muy (1)10ny Ratio No. Mux Muy ft kip-ft kip-ft y)Mnx kip-ft kip-ft 4Mny L1 99-67(1) TP26x26x0.375 177.04 624.25 0.284 0.00 624.25 0.000 L2 67-31.79(2) TP30.75x25.5x0.1875 460.97 562.11 0.820 0.00 562.11 0.000 L3 31.79-0(3) TP35x29.7787x0.25 839.98 1061.95 0.791 0.00 1061.95 0.000 Pole Shear Design Data a Section Elevation Size Actual (f•Vn Ratio Actual +Tn Ratio No. Vu Vu Tu Tu ft K K 4Vn kip-ft kip-ft 47;) L1 99-67(1) TP26x26x0.375 8.45 475.47 0.018 0.26 1000.90 0.000 tnxTower Report-version 8.0.2.1 ` September 07, 2018 99 Ft Monopole Tower Structural Analysis CCI BU No 825028 Project Number 1613851, Order 449094, Revision 1 Page 19 Section Elevation Size Actual Olin Ratio Actual 4Tn Ratio No. Vu Vu Tu Tu R K K 4)1/n kip-ft kip-ft pTn L2 67-31.79(2) TP30.75x25.5x0.1875 9.82 456.35 0.022 0.26 1126.67 0.000 L3 31.79-0(3) TP35x29.7787x0.25 11.09 742.58 0.015 0.26 2128.81 0.000 Pole Interaction Design Data Section Elevation Ratio Ratio Ratio Ratio Ratio Comb. Allow. Criteria No. Pu Mu, Muy Vu Tu Stress Stress ft 4Pn +Mnx 4Mny cVn .Tn Ratio Ratio L1 99-67(1) 0.011 0.284 0.000 0.018 0.000 0.295 1.000 4.8.2 L2 67-31.79(2) 0.014 0.820 0.000 0.022 0.000 0.835 1.000 4.8.2 L3 31.79-0(3) 0.012 0.791 0.000 0.015 0.000 0.803 1.000 4.8.2 Section Capacity Table Section Elevation Component Size Critical P rPPrww % Pass No. ft Type Element K K Capacity Fail L1 99-67 Pole TP26x26x0.375 1 -10.14 950.95 29.5 Pass L2 67-31.79 Pole TP30.75x25.5x0.1875 2 -12.76 912.69 83.5 Pass L3 31.79-0 Pole TP35x29.7787x0.25 3 -17.37 1485.15 80.3 Pass Summary Pole(L2) 83.5 Pass „ .. . RATING= 83.5 Pass tnxTower Report-version 8.0.2.1 September 07, 2018 99 Ft Monopole Tower Structural Analysis CCI BU No 825028 Project Number 1613851, Order 449094, Revision 1 Page 20 APPENDIX B BASE LEVEL DRAWING tnxTower Report-version 8.0.2.1 // /� ". . (1))11-D3/55,TO 96 FT LEVET. / ./A: (INSTALLED-TO BE REMOVED) / (1) 5/16"TO 96 FT LEVEL (12) 7/8"TO 96 FT LEVEL 1 I I o � I I wN I I (IN(2)51/4 GROUND TO 80 FT LEVEL 1 \ \ \ I• \ \ / / (RESERVED) . \ \ (4) 1-7/16"TO 80 FT Y., \ " // / 4. \ —.-—mo / i / i BUSINESS UNIT: 825028 TOWER ID:C_BASELEVEL September 07, 2018 99 Ft Monopole Tower Structural Analysis CC/BU No 825028 Project Number 1613851, Order 449094, Revision 1 Page 21 APPENDIX C ADDITIONAL CALCULATIONS tnxTower Report-version 8.0.2.1 Y � Monopole Flange Plate Connection Elevation=67 ft. CCROWN CASTLE BU# 825028 Site Name King City Moment(kip-ft) 177.04 Order# 449094 Rev 1 Axial Force(kips) 10.14 Shear Force(kips) 8.45 TIA-222 Revision G Top Mate-Internal Bottom Mate-Internal 0 � 4:JO 0 0 0 Connection Properties Bolt Data (12)1"0 bolts(A325 N;Fy=92 ksi,Fu=120 ksi)on 22"BC Top Plate Data Bottom Plate Data 19"ID x 1.5"Plate(A572-50;Fy=50 ksi,Fu=65 ksi) 19.5"ID x 1.5"Plate(A572-50;Fy=50 ksi,Fu=65 ksi) Top Stiffener Data Bottom Stiffener Data N/A N/A Top Pole Data Bottom Pole Data 26"x 0.375"round pole(A53-B-35;Fy=35 ksi,Fu=60 ksi) 25.5"x 0.1875"18-sided pole(A572-50;Fy=50 ksi,Fu=65 ksi) Analysis Results Bolt Capacity Max Load(kips) 31.32 Allowable(kips) 54.53 Stress Rating: 57.4% Pass Top Plate Capacity Bottom Plate Capacity Max Stress(ksi): 14.43 Max Stress(ksi): 13.80 Allowable Stress(ksi): 45.00 Allowable Stress(ksi): 45.00 Stress Rating: 32.1% Pass Stress Rating: 30.7% Pass Tension Side Stress Rating: 8.8% Pass Tension Side Stress Rating: 8.4% Pass CClplate -version 3.1.0.3 Analysis Date:8/20/2018 Monopole Base Plate Connection CROWN 0:: CASTLE Site Info BU# 825028 Site Name King City Order# 449094 Rev 1 „` `� Analysis Considerations `^/)�) / TIA-222 Revision G Grout Considered: No lar(in) 0 Eta Factor,q 0.5 Moment(kip-ft) 839.98 Axial Force(kips) 17.37 Shear Force(kips) 11.09 O Connection Properties Analysis Results Anchor Rod Data Anchor Rod Summary (units of kips,kip ft) (4)2-1/4"0 bolts(A615-75 N;Fy=75 ksi,Fu=100 ksi)on 43.4375"BC Pu=236.14 cl)Pn=260 Stress Rating Vu=2.77 On=n/a 93.0% Base Plate Data Mu=n/a 4'Mn=n/a Pass 43"OD x 1.75"Plate(A572-50;Fy=50 ksi,Fu=65 ksi) Base Plate Summary Stiffener Data Max Stress(ksi): 11.24 (8)18"H x 6"W x 0.75"T,Notch:0.75" Allowable Stress(ksi): 27 plate:Fy=50 ksi;weld:Fy=70 ksi Stress Rating: 41.6% Pass horiz.weld:0.375"groove,45°dbl bevel,0.25"fillet vert.weld:0.25"fillet Stiffener Summary Horizontal Weld: 45.7% Pass Pole Data Vertical Weld: 44.8% Pass 35"x 0.25"18-sided pole(A572-50;Fy=50 ksi,Fu=65 ksi) Plate Flexure+Shear: 11.7% Pass Plate Tension+Shear: 46.8% Pass Plate Compression: 47.4% Pass Pole Summary Punching Shear: 17.5% Pass CClplate-version 3.1.0.3 Analysis Date:8/20/2018 Drilled Pier Foundation Bt,#: 82828y (XCRQWN ,, CASTLE Site Name: Kin Cit Order Number:449094 Rev 1 TIA-222 Revison: G Tower Type: Monopole Analysis Results Check Limitation Applied Loads Soil Lateral Capacity Compression Uplift N/A L' Comp. Uplift D„4,(ft from TOC) 5.74 - Moment(kip-ft) 840 Soil Safety Factor 5.60 - Axial Force(kips) 17 Max Moment(kip-ft) 890.56 - Shear Force(kips) 11 Rating 23.8% - Soil Vertical Capacity Compression Uplift Material Properties Skin Friction(kips) 52.97 - Concrete Stren•th,f c: 4 ksi End Bearing(kips) 204.02 - Rebar Stren•th,F : 60 ksi Weight of Concrete(kips) 83.41 - Total Capacity(kips) 256.99 - Pier Design Data Axial(kips) 100.41 - Depth 21 ft Rating 39.1% - Ext.Above Grade 1 ft Reinforced Concrete Capacity Compression Uplift Pier Section 1 Critical Depth(ft from TOC) 5.45 - From 1'above grade to21'below grade Critical Moment(kip-ft) 890.31 - Pier Diameter 5.5 ft Critical Moment Capacity 2366.65 - Rebar Quantity 12, Rating 37.6% - Rebar Size 11 Clear Cover to Ties 4 in Soil Interaction Rating 39.1% _ Tie Size 5 Structural Foundation Rating 37.6% Soil Profile Groundwater Death 15 ft #of La ers 5 Calculated Calculated Ultimate Skin Ult.Gross TopBottom Thickness Angle of Ultimate Skin Layer Ysae ycnn«•tc Cohesion Ultimate Skin Ultimate Skin Friction Comp Bearing SPT Blow Y Friction Friction Uplift Soil Type (ft) (ft) (ft) (pcf) (pcf) (ksf) Friction Comp Friction Uplift Override Capacity Count (degrees) (ksf) (ksf) (ksf) Override(ksf) (ksf) 1 0 2 2 110 150 0 0 0.000 0.000 0.00 0.00 Cohesionless 2 2 7.5 5.5 110 150 0 35 0.000 0.000 0.15 0.15 Cohesionless 3 7.5 15 7.5 110 150 0 37 0.000 0.000 0.30 0.30 Cohesionless 4 15 20.5 5.5 47.6 87.6 0 33 0.000 0.000 0.15 0.15 Cohesionless 5 20.5 21 0.5 47.6 87.6 0 40 0.000 0.000 0.38 0.38 11.45 Cohesionless Version 2.0.2 ASCE ASCE 7 Hazards Report AMERICAN SOCIETY OF CNF ENGINEERS Address: Standard: ASCE/SE17-10 Elevation: 265.09 ft(NAND 88) No Address at This Risk Cate o II Location g �� Latitude: 45.420611 Soil Class: D Stiff Soil Longitude: 122.784306 f .t .- ` �a t � ,K*0-",10 , , - * Vr— K.;.., �. • .d j ".' ,� 1 s rYF ,aha Y 1.: a. 4 a't tttlllt�� � � � �*�'� 1 + r L YY t r q ".siikiiviti r ✓ k=Iti`- w a r 1, .4,-- \ v "../...7 , ,,,,:tr *-•0 ,,,,,.: ,„, , n v 7. _ . t sit , ,. _ -,s°'r �xx xji, 1 ��.i. a w»`< .esiet https://asce7hazardtool.online/ Page 1 of 3 Fri Aug 17 2018 ASCE AMERICAN SOCIETY OF CMI.ENGINEERS Seismic Site Soil Class: D-Stiff Soil Results: Ss : 0.963 SDs : 0.716 Si : 0.421 SD1 : 0.443 Fa : 1.115 TL : 16.000 F, : 1.579 PGA: 0.422 Skis : 1.074 PGA M : 0.455 SM1 : 0.665 FPGA : 1.078 le : 1 Seismic Design Category D 1Q MCER Response Spectrum Q 75 Design Response Spectrum .00 0.70 0.65 .90 Q 60 .80 1 0.55 70 0.50 0.45 .60 0.40 .50 0.35 0.30 40 0.25 .30 0.20 'c;'`, Q } Q h h- h h h h- h A h �O Q(.;/tidS "' fC) ",� - h^5 hT? h h h ?9‘1,9' 4' t5. CS' (5' Sa(g)vs T(s) Sa(g)vs T(s) Data Accessed: Fri Aug 17 2018 Date Source: USGS Seismic Design Maps based on ASCE/SEI 7-10, incorporating Supplement 1 and errata of March 31, 2013, and ASCE/SEI 7-10 Table 1.5-2. Additional data for site-specific ground motion procedures in accordance with ASCE/SEI 7-10 Ch. 21 are available from USGS. https://asce7hazardtool.online/ Page 2 of 3 Fri Aug 17 2018 ASCE. AMERICAN SOCIETY OF CIVIL ENGINEERS Ice Results: Ice Thickness: 1.00 in. Concurrent Temperature: 25 F Gust Speed: 30 mph Data Source: Standard ASCE/SEI 7-10, Figs. 10-2 through 10-8 Date Accessed: Fri Aug 17 2018 Ice thicknesses on structures in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. Values provided are equivalent radial ice thicknesses due to freezing rain with concurrent 3-second gust speeds, for a 50-year mean recurrence interval, and temperatures concurrent with ice thicknesses due to freezing rain. Thicknesses for ice accretions caused by other sources shall be obtained from local meteorological studies. Ice thicknesses in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. The ASCE 7 Hazard Tool is provided for your convenience,for informational purposes only,and is provided"as is"and without warranties of any kind.The location data included herein has been obtained from information developed,produced,and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE 7 standard.While ASCE has made every effort to use data obtained from reliable sources or methodologies,ASCE does not make any representations or warranties as to the accuracy,completeness,reliability, currency,or quality of any data provided herein.Any third-party links provided by this Tool should not be construed as an endorsement, affiliation,relationship,or sponsorship of such third-party content by or from ASCE. ASCE does not intend,nor should anyone interpret,the results provided by this Tool to replace the sound judgment of a competent professional,having knowledge and experience in the appropriate field(s)of practice,nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard. In using this Tool,you expressly assume all risks associated with your use.Under no circumstances shall ASCE or its officers,directors, employees,members,affiliates,or agents be liable to you or any other person for any direct,indirect,special,incidental,or consequential damages arising from or related to your use of,or reliance on,the Tool or any information obtained therein.To the fullest extent permitted by law,you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE 7 Hazard Tool. https://asce7hazardtool.online/ Page 3 of 3 Fri Aug 17 2018 r ' CROWN 825028 Structure: A 1613851 CASTLE 449094 Rev: Location : Decimal Degrees Lat: 45.4206 Long: 422.7843 Code and Site Parameters Building Code: 2012 IBC Seismic Design Code: ASCE 7-10 Site Soil: D Stiff Soil(Default) Risk Category: II Ss: 0.9630 USGS Seismic Reference S1: 0.4210 IL: 16 Ses r-sign Category Determt i= Importance Factor,la: 1 Acceleration-based site coefficient,Fa: 1.1148 Velocity-based site coefficient,F,,: 1.5790 Design spectral response acceleration short period,Sps: 0.7157 Design spectral response acceleration 1 s period,SDI: 0.4432 Seismic Design Category Based on SDS: D Seismic Design Category Based on SDI: D Seismic Design Category Based on SI: N/A Controlling Seismic Design Category. CCISeismic 3.0.1 Page 1 Analysis Date: 8/17/2018 CROWN„....•jr.,„ BU: 825028 Structure: A CASTLE WO 1613851 Order: 449094 Rev: 1 ower Details Tower Type: Tapered Monopole Height,h: 99 ft Effective Seismic Weight,W: 11.20 kips Seismic Base Shear Response Modification Factor,R: 1.5 Fundamental Period,T: 1.8700 Seismic Response Coefficient,C, 0.4771 12.8-2 Seismic Response Coefficient Max 1,C,„,ax 0.1580 12.8-3 Seismic Response Coefficient Max 2,C,„,.„ N/A 12.8-4 Seismic Response Coefficient Min 1,C,,,0 0.0315 15.4-1 Seismic Response Coefficient Min 2,C,,,,, N/A 15.4-2 Controlling Seismic Response Coefficient,C,, 0.1580 Seismic Base Shear,V r -K-r 12.8-1 T'''' Vertical Distribution Factors Period Related Exponent,k: 1.685 12.8-12 Sum of w;h,k 12970.57 12.8-12 CCISeismic 3.0.1 Page 2 Analysis Date: 8/17/2018 • Tow Section Loads TNX Factored Loads SectionSection Number Length Top Height Mid Height,h, Weight,w, w,h,t C F,n F� Sheer Weightl WNght2 1 1 ., 6,00000 6.00 tiJ � 0(70000 .r 'IG . CCISeismic 3.0.1 Page 3 Analysis Date: 8/17/2018 • C-trete Loa�k TNX Factored Loads Name h N,h� C F„ Sheer Weightl Weight2 I I CCISeismic 3.0.1 Page 4 Analysis Date: 8/17/2018 Name Start Height End Height h, w, w,h; 4. F,,, F„, Shear Weightl Weight2 . 190, ;; 14)sprl I.._w80 I., CCISeismic 3.0.1 Page 5 Analysis Date: 8/17/2018 99.0ft I I r I I —_, DESIGNED APPURTENANCE LOADING TYPE i ELEVATION I TYPE ELEVATION Tower Section 1-1 '98 samsung telecommunications OPTIC 80 andrew HBXXE5I6DS-A2M w!Mount 96 FIBER JUNCTION CYLINDER Pipe samsung telecommunications 80 andrew HBXX-6516DS-A2M wl Mound 96 POWER JUNCTION CYLINDER Pipe samstmg telecommunications 80 andrew HBXX-6516DS-A2M w!Mount 96 POWER JUNCTION CYLINDER 1 0 , o o ' ' Pine samsung telecommunications 80 M $ M commscope FFHH-65C-R3 w1 Mount '96 POWER JUNCTION CYLINDER Pi 1 ``e Pipe tower mauls Platform Mount[LP 80 camsmpe FFHH-65C-R3 WI Mount 96 301-11 { Pipe (4)sprint TYPE 11(1-7116)From 0 to 80 79.5 commscope FFHH-65C-R3 WI Mount 96 (7911 to8oft) Pipe nokia ASU93251YP01(1-315)From 0 74 nokia AHLOA 96 to 96(69ft to79(t) nate AHLOA 96 (4)sprint TYPE 11(1-7116)From 0 to 80 74 nokia A1LOA 96 (6911 to79ft) ' nokia AHFIB 96 Tower Section 1-4 72 rtolda AHFIB 96 Tower Section 2-1 64.395 nokia AHFIB tower mounts Side Ann Mount(SO 64 302-31 a,, 67.0 ft (2)nate FXFC 96 nokia ASU9325TYP01(1-315)From 0 64 E9 raycap RNSNDC-7771-PF-48 96 to 96(59ft 1069ft) i RMQP-3XX+F3P-HRK12 96 (4)sprint TYPE 11(1-7/16)From 0 to 80 64 tower mounts 8'x Y Mount Pipe 96 (5911t069ft) tower mounts 8'x Y Mount Pipe 96 Tower Section 2-2 56.79 tower mounts 8'x2"Mount Pipe 96 nokia ASU93251YP01(1-315)From 0 54 nokia ASU9325TYP01(1.3/5)From 0 92.5 to 96(49ft to59ft) to 96(89111096tt) (4)sprint TYPE 11(1-7/16)From 0 to 80 54 Tower Section 1-2 92 '(4911 to59ft) nokia ASU9325TYP01(1-315)From 0 84 Tower Section 2-3 46.79 to 96(79ft to89R) nokia ASU9325TYPOI(1-315)From 0 44 Tower Section 1-3 82 to 96(39ft t0498) commscope DHHTT65B-3XR 80 (4)sprint TYPE 11(1-7/16)From 0 to 80 44 commscope DHHTT65B-3XR 80 ( ) $ n oo $ o commscope DHHTT65B-3XR 80 -Tower Section 2-4 36.79 N w m ro v 'r? `u',^ of a rfs CehVBYe APXVSPPIB-C-A20 80 nokia ASU9325TYP01(1-3/5)From 0 34 „�, • o W N a to 96(29ft to39ft) nfscelwave APXVSPP18-C-A20 80 rfs cekvave APXVSPPIB-GA20 (4)sprint TYPE 11(1-7/16)From 0 to 80 34 (29ft to39(t) sar sung teiecommunicatans RRH-P4 80 Tower Section 3-1 33.105 samsung telecommunications RRH-P4 80 Tower Section 3-2 25 samsung telecommunications RRH-P4 80 nokia ASU9325TYP01(1-3/5)From 0 24 samsung telecommunications RRH-B8 80 to 96(1911 to291) samsung telecommunications RRH-B8 80 (4)sprint TYPE 11(1-7/16)From 0 to 80 24 samsung telecommunications RRH-B8 80 (198 to29(t) samsung telecommunications 80 Tower Section 3-3 15 / RRH-C2C nokia ASU9325TYP01(1315)From 0 14 / samsung telecommunications 80 to 96(Oft to1911) ,/J/ o RRH-C2C (4)sprint TYPE 11(1-7/16)From 0 to 80 14 N (911 to1911) 31.8 ft RRH-C2C 80 a Tower Section 3-4 5 ericsson 800MHZ SMR FILTER 80 nokia ASU9325rYP01(13/5)From 0 4.5 ericsson 800MHZ SMR FILTER 80 to 96(Oft to911) ericsson 800MHZ SMR FILTER 80 (4)sprint TYPE 11(1-7/16)From 0 to 80 4.5 samsung telecommunications OPTIC 80 (ort tu91t) FIBER JUNCTION CYLINDER samsung telecommunications OPTIC 80 FIBER JUNCTION CYLINDER MATERIAL STRENGTH 0 o GRADE Fy Fu GRADE 1 Fy Fu N PI o O A53-8-35 35 ksi 60 ksi A572-50 i 50 ksi 65 ksi M - N nm $C TOWER DESIGN NOTES ALL REACTIONS 1. Tower is located in Washington County,Oregon. ARE FACTORED 2. Tower designed for Exposure B to the TIA-222-G Standard. 3. Tower designed for a 1.00 mph basic wind in accordance with the TIA-222-G Standard. 4. Tower Risk Category II. AXIAL 5. Topographic Category 1 with Crest Height of 0.0000 ft 19 K 6. CCISeismic 3.0 Analysis 7. All seismic forces calulated in CCISeismic are input as factored user forces SHEAR MOMENT 8. Wind area factors of structure have been set to 0 2 K 154 kip-ft 9. All feed lines,discrete loads,and dishes have been disabled.Appurtenance dead load is accounted for in the user forces 0.0 ft I I REACTIONS-1.00 mph WIND 10. Structure and guy dead loads are calculated by TNX and not included in user forces m11. Load Combination 1.2D+Eh+Ev la co •6 `b' 12. TOWER RATING:17.4% a 8 a a SP Job:Crown Castle BU#825028 CROWNT2000 Corporate Drive cram°"� Canonsburg, PA 15317client Crown Castle �`Matthew Schmitt Ap>pd: The Foundation fora Wireless World Phone:(724)416-2000 Cede.TIA-222-G Date:08/17/18 Scale:NTS FAX: Path: 13"No-E-1 September 07, 2018 99 Ft Monopole Tower Structural Analysis CCI BU No 825028 Project Number 1613851, Order 449094, Revision 1 Page 22 APPENDIX D REQUIRED MODIFICATION DRAWINGS tnxTower Report-version 8.0.2.1