Specifications (38) 'MT -O\ - 00 1.5
CS Beam 2018.1.0.10 I-IUTTIG#804026 4-16-18, -l' ✓ S VQ 1$(\-e:1 St
kmBeamEngme 2018.1.0.1
Materials Database 1566 1:36pm
1 of 1
•
Member Data
Description:UPPER FLOOR Member Type:Joist Application:Floor • i'''''' '''"---$ h
• (J1)JOIST Top Lateral Bracing:Continuous , a"! A t 1Virzil
Bottom Lateral Bracing:Continuous Y. _•
Standard Load: Moisture Condition:Dry Building Code:IBC/IRC
Live Load: 40 PSF Deflection Criteria: L/600 live,L/360 total A[,p ?0;3
Dead Load: 15 PSF Deck Connection:Glued&Nailed Fy f t ,d c
Filename:804026-UPPER
Joist Design Includes CCMC Vibration Check d (r s z--
Subfloors 23/32"OSB r E .s`P 1 t T
Ceiling: 1/2"gypsum Blocking:(See Requirements Below) ,i_ t "g %�� 4-.A
• � !
T
/ T li ,
14 2 8 /® 6 4 0 18 11 0 ®,
3958
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0'0.000" Wall SPF Plate(425psi) 3.500" 1.500" 448# --
2 14'2.500" Wall SPF Plate(425psi) 3.500" 3.500" 941# -3#
3 20'6.500" Wall SPF Plate(425psi) 3.500" 3.500" 1431# --
4 39' 5.500" Wall SPF Plate(425psi) 3.500" 1.500" 562# --
• Maximum Load Case Reactions
Used for apq„ng point loads(or line bads)to carving members
Live Dead
1 327#(246pR) 121#(91 pM)
2 778#(584pif) 163#(122p/f)
3 1087#(815p1f) 344#(258pif)
4 410#(307pif) 153#(114p1f) .
Design spans
13'11.875" 6'4.000" 18' 8.375"
• Product: 11 7/8" LPI-20 Plus 16.0"O.C. PASSES DESIGN CHECKS
• Blocking:Blocking @ midspan between Bearing#3 and Bearing#4
• Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Lateral support is required at each bearing.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 2155'8 375530 57% 31.76' Odd Spans D+L
Negative Moment 2479.'# 3755.'# 66% 20.54' Adjacent 2 D+L
Shear 818.# 1485.8 55% 20.54' Adjacent 2 D+L
End Reaction 562.# 1122.8 50% 39.46' Odd Spans D+L
• Int.Reaction 1431.# 2330.# 61% 20.54' Adjacent 2 D+L
TL Deflection 0.3488" 0.6233" L/643 30.83' Odd Spans D+L
' LL Deflection 0.2554" 0.3740" L/878 30.83' Odd Spans L
Vibration 0.0222" 0.0338" 66%
Control: LL Deflection
DOLS: Live=100% Snow=115% Roof=125% Wind=160%
•
" All product names are trademarks of their respective owners Huttig Building Products-CL
This calc comforms to ORS2005,
Copydght(C)2018 by Simpson Shong.Tie Company lnc.ALL RIGHTS RESERVED. NDS2001 and 20050R5 C.
"Passing is defined as when the member.floor joist,beam or girder shown on this drawing meets applicable design criteria for Loads,Loading Conditions,and Spans listed on .
this sheet.The design must be reviewed bya qualified designer or design professional as required for approval.TMs design assumes product lsallatlon according to the •
manufacturers speclficetions. _ _ ,
1
Cs Beam 2018.1.0.10 HUTTIG#804026 4-16-18
ImrBeamE gtrtc 2018.1.0.1
Materials Database 1566 1:31pm
1 of 1
Member Data
Description:UPPER FLOOR Member Type:Joist Application:Floor
Top Lateral Bracing:Continuous •
Bottom Lateral Bracing:Continuous
Standard Load: Moisture Condition:Dry Building Code:IBC/IRC
Live Load: 40 PSF Deflection Criteria: L/600 live,L/360 total •
Dead Load: 15 PSF Deck Connection:Glued&Nailed
Filename:Beam3
Joist Design Includes CCMC Vibration Check
Subfloor.23/32"OSB
Ceiling: 1/2"gypsum Blocking:(See Requirements Below)
•
• / 21 74
21 7 4
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0'0.000" Wall SPF Plate(425psi) 3.500" 1.500" 586# --
2 21'7.250" Wall SPF Plate(425psi) 2.000" 1.500" 586# --
Maximum Load Case Reactions
Used for applying point loads or line loads)to carrying members
Live Dead
1 426#(426p1f) 160#(160p1f)
2 426#(426p1f) 160#(160plt)
Design spans
21' 3.500"
Product: 11 7/8"LPI-56 12.0"O.C. PASSES DESIGN CHECKS
Blocking:(None)
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Lateral support is required at each bearing.
• Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 3117.'# 10170'# 30% 10.86' Total Load D+L
Shear 586.# 2055.# 28% 0' Total Load D+L
End Reaction 586.# 1219.# 48% 21.6' Total Load D+L
TL Deflection 0.4031" 0.7097" L/633 10.86' Total Load D+L
LL Deflection 0.2932" 0.4258" L/871 10.86' Total Load L
Vibration 0.0270" 0.0311" 87%
Control: Vibration
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
•
•
All product names are trademarks of their respective owners Huttig Building Products-CL
This calc comforms to ORS2005,
Copyaght(0)2016 by Simpson Strong-Tie Company Inc.ALL RIGHTS RESERVED. NDS2001 and 2005ORSC.
"Passing is defined as when the member.floorjoist,beam or girder,shown on this drawing meets applicable design criteria for Loads,Loading Conditions,and Spans listed on
this sheet.The design must be reviewed bya qualified designer or design professional as required for approval.This design assumes product Installation according to the
manufacturers specifications.
CS Beau 2018.1.0.10 HUTTIG#804026 4-16-18-
kmBea E Igme 2510.1.01
Materials Database 1566 1:38pm .
loft
Member Data
Description:UPPER FLOOR Member Type:Joist Application:Floor
(J3)JOIST Top Lateral Bracing:Continuous
Bottom Lateral Bracing:Continuous
Standard Load: Moisture Condition:Dry Building Code:IBC/IRC
Live Load: 40 PSF Deflection Criteria: L/600 live,L/360 total
Dead Load: 15 PSF Deck Connection:Glued&Nailed •
Filename:804026-UPPER
Joist Design Includes CCMC Vibration Check
Subfloors 23/32"OSB
Ceiling: 1/2"gypsum Blocking:(See Requirements Below)
•
14 3 8 6 3 0
2068
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0'0.000" Wall SPF Plate(425psi) 3.500" 1.500" 424# --
2 14' 3.500" Wall SPF Plate(425psi) 3.500" 3.500" 1061# --
3 20'6.500" Wall SPF Plate(425psi) 2.000" 1.500" 153# -147#
Maximum Load Case Reactions
Used fa applying point loads(or line loads)In carrying members
Live Dead
1 310#(233plf) 114#(860)
2 772#(5790) 2891l(217p8)
. 3 152#(114p1f) 1#(1p1f)
• Design spans
14' 0.875" 6' 1.875"
Product: 11 7/8"LPI-18 16.0"O.C. PASSES DESIGN CHECKS
•
Blocking:(None)
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Lateral support is required at each bearing.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 1226.'# 3100.W 39% 5.85' Odd Spans D+L
Negative Moment 1369.'# 3100.'# 44% 14.29' Total Load D+L
Shear 613.# 1335.# 45% 14.28' Total Load D+L
End Reaction 424.# 1006.# 42% 0' Odd Spans D+L
Int.Reaction 1061.# 2095.# 50% 14.29' Total Load D+L
TL Deflection 0.1456" 0.4691" L/999+ 6.55' Odd Spans D+L
LL Deflection 0.1076" 0.2815" L/999+ 6.55' Odd Spans L
Vibration 0.0190" 0.0484" 39%
Control: Max Int.React.
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
All product names are trademarks of theirrespearoe owners Huttig Building Products-CL
This calc comforms to ORS2005,
CopC)2016 by Simpson Strong-Tie Companylnc.ALL RIGHTS RESERVED. NDS2001 and 2005ORS C.
"'Passing is defined as when the member,floor joist,beam or gine,shown on this drawing meets applicable design criteria for Loads,Loading Conditions,and Spans listed on this sheet.The design must be rsviewed by a qualified designer or design professional as required for approval.This design assumes product installation according to the
manufacturers specifications.
Cs Beam 2018.1.0.10 HUTTIG#804026 4-16-18
kmBeamFatghte 2018.1.0.1
Materials Database 1566 1:36pm
loft
Member Data •
Description:UPPER FLOOR Member Type:Joist Application:Floor
• (J4)JOIST Top Lateral Bracing:Continuous
Bottom Lateral Bracing:Continuous
Standard Load: Moisture Condition:Dry Building Code:IBC/IRC
Live Load: 40 PSF Deflection Criteria: L/600 live,L/360 total
Dead Load: 15 PSF Deck Connection:Glued&Nailed
Filename:804026-UPPER
Joist Design Includes CCMC Vibration Check
Subfloors 23/32"OSB
Ceiling: 1/2"gypsum Blocking:(See Requirements Below)
5"
1811 0
18 11 0
Bearings and Reactions
Input Min Gravity Gravity
•
Location Type Material Length Required Reaction Uplift
• 1 0'0.000" Wall SPF Plate(425psi) 2.000" 1.500" 682# --
2 18.11.00V Wall SPF Plate(425psi) 3.500" 1.500" 682# --
Maximum Load Case Reactions
Used for applying point loads on line loads)to canying members
Live Dead
1 496#(372plf) 186#(140plf)
• 2 496#(372p1f) 186#(140p1f)
Design spans
18' 7.250"
Product: 11 7/8"LPI-56 16.0"O.C. PASSES DESIGN CHECKS
Blocking:Blocking @ midspan between Bearing#1 and Bearing#2
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Lateral support is required at each bearing.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 3173W 10170.' 31% 9.4' Total Load D+L
Shear 682.9 2055.9 33% 0' Total Load D+L
End Reaction 682.9 1219.9 55% 0' Total Load D+L
TL Deflection 0.3192" 0.6201" L/699 9.4' Total Load D+L
LL Deflection 0.2322" 0.3721" L/961 9.4' Total Load L
Vibration 0.0201" 0.0338" 59%
Control: LL Deflection
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
All product names are trademarks of their respective owners Huttig Building Products-CL
This calc comforms to ORS2005,
Copyright(C)2016 by Simpson Strong-Tie Companylnc.ALL RIGHTS RESERVED. NDS2001 and 20050RSC.
"Passing is defined as when the member,floor joist,beam orgirdet shown on this drawing meets applicable design criteria for Loads,Loading Conditions.and Spans listed on
this sheet.The design must be reviewed bya qualified designer or design professional as required forappnrval.Ibis design assumes product installation according to the
manufacturers speciflcatlons.
CS Beam 2018.1.010 HUTTIG#804026 4-16-18
IonBeamUaginc 2018.1.0.1 m 1:37
Materials Database 1866 P
loft
Member Data
Description:UPPER FLOOR Member Type:Joist Application:Floor
(J5)JOIST Top Lateral Bracing:Continuous
Bottom Lateral Bracing:Continuous
Standard Load: Moisture Condition:Dry Building Code:IBC/IRC
Live Load: 40 PSF Deflection Criteria: L/600 live,L/360 total
Dead Load: 15 PSF Deck Connection:Glued&Nailed
Filename:804026-UPPER
Joist Design Includes CCMC Vibration Check
Subtloor:23/32"OSB
Ceiling: 1/2"gypsum Blocking:(See Requirements Below)
16 0 0
16 0 0
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0'0.000" Wall SPF Plate(425psi) 2.000" 1.500" 581# --
2 16'0.000" Wall SPF Plate(425psi) 1.750" 1.500" 581# --
Maximum Load Case Reactions
. Used for appleng point loads(online loads)to ca0hg members
Live Dead
1 422#(317p1f) 158#(119p1f)
2 422#(317plf) 158#(119plf)
Design spans
15'10.000"
Product: 11 7/8" LPI-18 16.0"O.C. PASSES DESIGN CHECKS
Blocking:(None)
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Lateral support is required at each bearing.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 2298.'# 3100.'# 74% 8.01' Total Load D+L
Shear 581.# 1335.# 43% 16' Total Load D+L
End Reaction 581.# 887.8 65% 16' Total Load D+L
TL Deflection 0.3914" 0.5278" L/485 8.01' Total Load D+L
LL Deflection 0.2847" 0.3167" L/667 8.01' Total Load L
Vibration 0.0308" 0.0412" 75%
Control: LL Deflection
DOLS: Live=100% Snow=115% R001=125./0 Wind=160%
All product names are trademarks of their respective owners Huttig Building Products-CL
This calc comforms to ORS2005,
Copyright(C)2016 by Simpson Strang-Tie Company Inc.ALL RIGHTS RESERVED. NDS2001 and 2005ORSC.
”Passing Is defined as when the member,floorjoisl.beam or gishown on this drawing meets applicable design criteria for Loads.Loading Conditions,and Spans listed on
or Loads.this sheet.The design must be reviewed bya qualified designer or design pmfessioml as required for approval.This design assumes product installation according to the
manufacturer's specifications.
CS Beam 2018.1.0.10 HUTTIG#804026 -, 4-16-18
kmBeamEnghe 2018.1.0.1 2:4�y,.,.,
Materials Database 1566 "1""
l oft
•
' Member Data •
Description:UPPER FLOOR Member Type:Joist Application:Floor
(J8)JOIST-CANTILEVER Top Lateral Bracing:Continuous
Bottom Lateral Bracing:Continuous
Standard Load: Moisture Condition:Dry Building Code: IBC/IRC '
Live Load: 40 PSF Deflection Criteria: L/600 live,L/360 total
Dead Load: 15 PSF Deck Connection:Glued&Nailed
Filename:Beams
Joist Design Includes CCMC Vibration Check
Subfloor.23/32"OSB
Ceiling: 1/2"gypsum Blocking:(See Requirements Below)
Other Loads
Type Other Dead
(Description) Side Begin End Start End Start End Category
Point(PLF) Top 8'4.00" 0 90 Live
WALL LOAD
Point(PLF) Top 8'4.00" 60 34 Snow .
HIGH ROOF:TW=2'
Point(PLF) Top 8' 4.00" 120 68 Snow
' LOW ROOF:TW=4'
t
m 1
�.. -._ ._ .. / /
7 3 8 1 0 8
P m /
8 4 0
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0'0.000" Wall SPF Plate(425psi) 2.000" 1.500" 225# --
2 7'3.500" WallSPF Plate(425psi) , 3.500" 3.500" 782# -- '
Maximum Load Case Reactions
Used for applying point loads(or line loads)to caning members
Live Snow Dead
1 192#(144p1f) -34#(-25p1f) 33#(25pt)
2 252#(1890) 275#(206plf) 387#(291plf)
Design spans
7' 2.375" 1' 0.500"(right cant)
Product: 11 7/8"LPI-18 16.0"O.C. PASSES DESIGN CHECKS
Blocking:(None)
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Lateral support is required at each bearing.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 345.'# 3100.'# 11% 3.33' Odd Spans D+L •
Negative Moment 528.'# 3565#/ 14% 7.29' Total Load D+S
Shear 306.# 1335.# 22% 7.28' Total Load D+L
Cant.Shear,RI 517.# 1535.# 33% 7.29' Total Load D+S
End Reaction 225.# 904.# 24% 0' Odd Spans D+L
Int.Reaction 782.# 2409.# 32% 7.29' Total Load D+0.75(L+S)
TL Deflection 0.0154" 0.2399" L/999+ 3.33' Odd Spans D+L '
- LL Deflection 0.0172" 0.1440" L/999+ 3.69' Odd Spans L
TL Defl.,Rt. 0.0069" 02000" 2L1999+ 8.33' Total Load D+S •
LL Defl.,Rt. -0.0050" 0.2000" 2L/999+ 8.33' Odd Spans L
Vibration0.0063" 0.0787" 8%
All pnxpa names are trademarks or their respective owner Huttig Building Products-CL
This calc comforms to ORS2005,
Copydight(C)2016 by Simpson Strong-Tie Company to.ALL RIGHTS RESERVED. NDS2001 and 20050RSC.
"Passing Is defined as when the member.floorjoiet,beam or girder shown on this droving meets applicable design cnte,ie for Loads,Loading Conditions,and Spans listed on
this sheet The design must be reviewed bye qualified designer or design professional as required for approval.This design assumes product Installation according to the -
manufacturer's specifications. _
CS Beam 2018.1.0.)0 HUTTIG#804026 4-16-18
imrBeamEsgute 2018.1.0.1
Materials Database 1566 2:40pm
2 of 2 •
Control: Max lot.React.
DOLs: Live=100%Snow=115% Roof=125% Wind=160%
Right cantilever allowable shear is for joist only •
•
•
•
•
•
All pmdum names are trademarks of their respective owner, Huttig Building Products-CL
This calc comforms to ORS2005,
Copplght(0)2016 by Simpson Sbong-Tie Company lnc.ALL RIGHTS RESERVED. NOS2001 and 2005ORSC.
"Passing is defined as when the member,floor joist,beam or girder shown on this drawing meets applicable design cntane for Loads,Loading Conditions,and Spans listed on
this sheet.The design must be reviewed bya qualified designer or design professional as required for appmvat.This design assumes product Installation according to the
manotacturere ifications.
CS Bean,2018.1.0.10 HUTTIG#804026 4-16-18
ImlBeamEgine2018.1.0.1 2:54
Materials Database 1566 pm
1 oft
Member Data .
Description:UPPER FLOOR Member Type:Joist Application:Floor
- (J9)JOIST-CANTILEVER Top Lateral Bracing:Continuous
Bottom Lateral Bracing:Continuous
Standard Load: Moisture Condition:Dry Building Code: IBC/IRC
Live Load: 40 PSF Deflection Criteria: L/600 live,L/360 total
Dead Load: 15 PSF Deck Connection:Glued&Nailed
Filename:804026-UPPER
Joist Design Includes CCMC Vibration Check
Subgoor 23/32"OSB
Ceiling: 1/2"gypsum Blocking:(See Requirements Below)
Other Loads
Type Other Dead
(Description) Side Begin End Start End Start End Category
Point(PLF) Top 6'4.00" 0 90 Live
WALL LOAD
Point(PLF) Top 6'4.00" 255 145 Snow
HIGH ROOF:1W=8.5'
Point(PLF) Top 6'4.00" 120 68 Snow
. LOW ROOF:TW=4'
I
Ti m
/ A
7 4 0
p
/ 0/
7 4 0
Bearings and Reactions
Input Min Gravity Gravity •
Location Type Material Length Required Reaction Uplift
1 0'0.000" Wall SPF Plate(425psi) 2.000" 1.500" 302# --
2 7'4.000" Wall SPF Plate(425psi) 3.500" 1.500" 903# --
' Maximum Load Case Reactions
Used for applying point loads(or line loads)to canons members
• Live Snow Dead
1 187#(140pIf) 56#(42p1f) 115#(66p1f)
2 187#(140pIf) 444#(333pIf) 429#(322plf)
Design spans
7' 0.250"
Product: 11 7/8"LPI-18 16.0"O.C. PASSES DESIGN CHECKS
•
Blocking:(None) .
Design assumes continuous lateral bracing along the top chord. .
Design assumes continuous lateral bracing along the bottom chord.
Lateral support is required at each bearing. .
Allowable Stress Design •
•
Actual Allowable Capacity Location Loading
Positive Moment 737.'# 3565.'# 20% 5.01' Total Load D+0.75(L+S)
Shear 903.# 1535.# 58% 7.33' Total Load D+0.75(L+S)
End Reaction 903.# 1157.# 78% 7.33' Total Load D+0.75(L+S)
TL Deflection 0.0353" 0.2340" L/999+ 3.96' Total Load D+0.75(L+S)
LL Deflection 0.0203" 0.1404" L/999+ 3.96' Total Load 0.75(L+S)
Vibration 0.0064" 0.0787" 8%
Control: Max End React.
DOLS: Live=100% Snow=115% Roof=125% Wind=160%
•
Ay product names are trademarks of thelrrespective owners Huttig Building Products-CL
This calc comforms to ORS2005,
Copysight(C)2016 by Simpson Stmng.Tie Company lnc.ALL RIGHTS RESERVED. N052001 and 2005ORS�..•.
or
'Ides sing is Wined as when the member,floor joist,beam or gia shown on this drawing wing meets applicable design mitefor Loads,Loading Conditions,and Spens listed on
this sheet.The design must be reviewed bya qualified designer or design professional as required for approval.This design assumes product installation according to the
manufacturers specifications.